Sample records for untransfected corneal endothelial

  1. New therapeutic modality for corneal endothelial disease using Rho-associated kinase inhibitor eye drops.

    PubMed

    Koizumi, Noriko; Okumura, Naoki; Ueno, Morio; Kinoshita, Shigeru

    2014-11-01

    Corneal endothelial dysfunction accompanied by visual disturbance is a primary indication for corneal endothelial transplantation. However, despite the value and potential of endothelial graft surgery, a strictly pharmacological approach for treating corneal endothelial dysfunction remains an attractive proposition. Previously, we reported that the selective Rho-associated kinase (ROCK) inhibitor Y-27632 promotes cell adhesion and proliferation, and inhibits the apoptosis of primate corneal endothelial cells in culture. These findings have led us to develop a novel medical treatment for the early phase of corneal endothelial disease using ROCK inhibitor eye drops. In rabbit and monkey models of partial endothelial dysfunction, we showed that corneal endothelial wound healing was accelerated via the topical application of ROCK inhibitor to the ocular surface, resulting in the regeneration of a corneal endothelial monolayer with a high endothelial cell density. Based on these animal studies, we are now attempting to advance the clinical application of ROCK inhibitor eye drops for patients with corneal endothelial dysfunction. A pilot clinical study was performed at the Kyoto Prefectural University of Medicine, and the effects of Y-27632 eye drops after transcorneal freezing were evaluated in 8 patients with corneal endothelial dysfunction. We observed a positive effect of ROCK inhibitor eye drops in treating patients with central edema caused by Fuchs corneal endothelial dystrophy. We believe that our new findings will contribute to the establishment of a new approach for the treatment of corneal endothelial dysfunction.

  2. Genetic engineering with endothelial nitric oxide synthase improves functional properties of endothelial progenitor cells from patients with coronary artery disease: an in vitro study.

    PubMed

    Kaur, Savneet; Kumar, T R Santhosh; Uruno, Akira; Sugawara, Akira; Jayakumar, Karunakaran; Kartha, Chandrasekharan Cheranellore

    2009-11-01

    Recent studies have reported a marked impairment in the number and functions of endothelial progenitor cells (EPCs) in patients with coronary artery disease (CAD). In view of an important role of eNOS in angiogenesis, in the present study, we evaluated the effects of eNOS gene transfer in ex vivo expanded EPCs isolated from patients with CAD. The expanded EPCs were transfected with mammalian expression vector pcDNA3.1-eNOS containing the full-length human eNOS gene using lipofectamine. About 35-40% of the eNOS-EPCs had higher expression of eNOS as compared to untransfected EPCs. EPCs transfected with pcDNA3.0-EGFP, the plasmid vector expressing green fluorescent protein (GFP) were used as control. The untransfected, GFP-transfected and eNOS-transfected EPCs were compared in terms of important functional attributes of angiogenesis such as proliferation, migration, differentiation and adhesion/integration into tube-like structures in vitro. Functional studies revealed that in the presence of defined growth conditions, compared to the untransfected and GFP-transfected cells, eNOS-EPCs from patients with CAD have a significant increase in [3H] thymidine-labeled DNA (P < 0.01), migration (14.6 +/- 1.8 and 16.5 +/- 1.9 vs. 23.5 +/- 3.4 cells/field, P < 0.01), ability to differentiate into endothelial-like spindle-shaped cells (46 +/- 4.5 and 56.5 +/- 2.1 vs. 93.2 +/- 6.6 cells/field, P < 0.001) and also incorporation into tube-like structures on the matrigel (GFP-EPCs: 21.25 +/- 2.9 vs. GFP-eNOS-EPCs: 34.5 +/- 5.5 cells/field, P < 0.05). We conclude that eNOS gene transfection is a valuable approach to augment angiogenic properties of ex vivo expanded EPCs and eNOS-modified EPCs may offer significant advantages than EPCs alone in terms of their clinical use in patients with myocardial ischemia.

  3. Corona sign: manifestation of peripheral corneal epithelial edema as a possible marker of the progression of corneal endothelial dysfunction.

    PubMed

    Inoue, Tomoyuki; Hara, Yuko; Kobayashi, Takeshi; Zheng, Xiaodong; Suzuki, Takashi; Shiraishi, Atsushi; Ohashi, Yuichi

    2016-09-01

    To describe a characteristic form of the corona sign and its clinical relevance to the degree of corneal endothelial decompensation and investigate the underlying mechanism using a rabbit model. These observational cases include 31 patients undergoing penetrating keratoplasty (PKP) and 15 patients undergoing Descemet stripping automated endothelial keratoplasty (DSAEK) with special attention to the circumferentially developed corneal epithelial edema. We also conducted a laboratory observation of horizontal water flow in the rabbit cornea. We consistently observed the corona sign at the superior periphery during the initial stage of corneal endothelial decompensation after PKP. With progressive corneal endothelial cellular loss, the epithelial edema gradually expanded circumferentially in the periphery. The endothelial cellular density associated with the corona sign significantly (P < 0.01) decreased compared with that without the sign. The endothelial cellular density decreased significantly (P < 0.05) in cases with a circumferential corona sign compared with a superior corona sign. After DSAEK, however, the corneal epithelial edema subsided from the center but persisted peripherally as a corona sign in all cases. By 3 months postoperatively, the epithelial edema was confined to the superior periphery along with uneventful corneal endothelial healing. Rabbit experiments showed that total corneal endothelial decompensation decreased the horizontal intracorneal water migration (Inoue-Ohashi phenomenon) in the corneal periphery and induced peripheral corneal edema. The slit-lamp microscopic findings of the corona-like epithelial edema in the peripheral cornea are associated with the stage of corneal endothelial function. To support this, the developmental mechanism of the corona sign was demonstrated experimentally.

  4. Molecular expression in transfected corneal endothelial cells

    NASA Astrophysics Data System (ADS)

    Wang, Fan; Miao, Zhuang; Lu, Chengwei; Hao, Jilong

    2017-10-01

    To investigate the capability of human corneal endothelial cells serving as immunological cells. Expression of HLA-DP, -DQ, -DR, CD40, CD80, and CD86 was determined by immunohistochemical methods. Meanwhile, purified peripheral blood mononuclear cells were cocultured with human corneal endothelial cells which were pre-treated with and without -IFN respectively, activation of lymphocytes was determined by FACS analysis. In coculture system, T lymphocyte was activated by corneal endothelial cells, HLA-DP, -DQ, -DR and CD40 expression were increased by - IFN induction. Costimulatory molecular CD80 was shown on the endothelial cells. Human corneal endothelial cells were assumed to be involved in the corneal transplantation rejection process as potential antigen presenting cells.

  5. Corneal transplantation trends in France from 2004 to 2015: A 12-year review.

    PubMed

    Bigan, Guillaume; Puyraveau, Marc; Saleh, Maher; Gain, Philippe; Martinache, Isabelle; Delbosc, Bernard; Gauthier, Anne-Sophie

    2018-04-01

    The aim of this study was to report the 12-year longitudinal trends in indication and corneal transplantation techniques in France from 2004 to 2015. The records of all corneal transplantations performed from 2004 to 2015 in France were retrospectively reviewed. The patient indications and types of transplant performed were analyzed. A total of 46,658 corneal transplantations were performed between 2004 and 2015, with 34,187 (73.3%) penetrating keratoplasty and 10,452 (22.4%) lamellar keratoplasty. The leading surgical indications were secondary endothelial failure (24.3%), keratoconus (18.8%), regraft (13.5%), and Fuchs endothelial corneal dystrophy (15.1%). Endothelial keratoplasty became the preferred technique for endothelial diseases and deep anterior lamellar keratoplasty the preferred technique for keratoconus, surpassing penetrating keratoplasty in 2013. Secondary endothelial failure is the top indication for performing a keratoplasty over the 12-year period. There was a shift from penetrating keratoplasty to endothelial keratoplasty performed for Fuchs endothelial corneal dystrophy and secondary endothelial failure, and to deep anterior lamellar keratoplasty, performed for keratoconus. This highlights an important shift in managing corneal diseases toward the application of selective and more conservative surgeries and changes in indications in corneal transplantation.

  6. Tissue Engineering of the Corneal Endothelium: A Review of Carrier Materials

    PubMed Central

    Teichmann, Juliane; Valtink, Monika; Nitschke, Mirko; Gramm, Stefan; Funk, Richard H.W.; Engelmann, Katrin; Werner, Carsten

    2013-01-01

    Functional impairment of the human corneal endothelium can lead to corneal blindness. In order to meet the high demand for transplants with an appropriate human corneal endothelial cell density as a prerequisite for corneal function, several tissue engineering techniques have been developed to generate transplantable endothelial cell sheets. These approaches range from the use of natural membranes, biological polymers and biosynthetic material compositions, to completely synthetic materials as matrices for corneal endothelial cell sheet generation. This review gives an overview about currently used materials for the generation of transplantable corneal endothelial cell sheets with a special focus on thermo-responsive polymer coatings. PMID:24956190

  7. Morphological Changes of Human Corneal Endothelial Cells after Rho-Associated Kinase Inhibitor Eye Drop (Ripasudil) Administration: A Prospective Open-Label Clinical Study

    PubMed Central

    Okumura, Naoki; Suganami, Hideki; Kinoshita, Shigeru

    2015-01-01

    Purpose To investigate the effect and safety of a selective Rho kinase inhibitor, ripasudil 0.4% eye drops, on corneal endothelial cells of healthy subjects. Design Prospective, interventional case series. Methods In this study, 6 healthy subjects were administered ripasudil 0.4% in the right eye twice daily for 1 week. Morphological changes and corneal endothelial cell density were examined by noncontact and contact specular microscopy. Central corneal thickness and corneal volume of 5 mm-diameter area of center cornea were analyzed by Pentacam Scheimpflug topography. All the above measurements were conducted in both eyes before administration, 1.5 and 6 hours after the initial administration on day 0; and in the same manner after the final administration on day 7. Results By noncontact specular microscopy, indistinct cell borders with pseudo guttae were observed, but by contact specular microscopy, morphological changes of corneal endothelial cells were mild and pseudo guttae was not observed after single and repeated administration of ripasudil in all subjects. These changes resolved prior to the next administration, and corneal endothelial cell density, central corneal thickness and corneal volume were not changed throughout the study period. Conclusion Transient morphological changes of corneal endothelial cells such as indistinct cell borders with pseudo guttae were observed by noncontact specular microscopy in healthy subjects after ripasudil administration. Corneal edema was not observed and corneal endothelial cell density did not decrease after 1 week repetitive administration. These morphological changes were reversible and corneal endothelial cell morphology returned to normal prior to the next administration. Trial Registration JAPIC Clinical Trials Information 142705 PMID:26367375

  8. Corneal endothelium: developmental strategies for regeneration

    PubMed Central

    Zavala, J; López Jaime, G R; Rodríguez Barrientos, C A; Valdez-Garcia, J

    2013-01-01

    The main treatment available for restoration of the corneal endothelium is keratoplasty. This procedure is faced with several difficulties, including the shortage of donor tissue, post-surgical complications associated with the use of drugs to prevent immune rejection, and a significant increase in the occurrence of glaucoma. Recently, surgical procedures such as Descemet's stripping endothelial keratoplasty have focused on the transplant of corneal endothelium, yielding better visual results but still facing the need for donor tissue. The emergent strategies in the field of cell biology and tissue cultivation of corneal endothelial cells aim at the production of transplantable endothelial cell sheets. Cell therapy focuses on the culture of corneal endothelial cells retrieved from the donor, in the donor's cornea, followed by transplantation into the recipient. Recently, research has focused on overcoming the challenge of harvesting human corneal endothelial cells and the generation of new biomembranes to be used as cell scaffolds in surgical procedures. The use of corneal endothelial precursors from the peripheral cornea has also demonstrated to be effective and represents a valuable tool for reducing the risk of rejection in allogeneic transplants. Several animal model reports also support the use of adult stem cells as therapy for corneal diseases. Current results represent important progresses in the development of new strategies based on alternative sources of tissue for the treatment of corneal endotheliopathies. Different databases were used to search literature: PubMed, Google Books, MD Consult, Google Scholar, Gene Cards, and NCBI Books. The main search terms used were: ‘cornea AND embryology AND transcription factors', ‘human endothelial keratoplasty AND risk factors', ‘(cornea OR corneal) AND (endothelium OR endothelial) AND cell culture', ‘mesenchymal stem cells AND cell therapy', ‘mesenchymal stem cells AND cornea', and ‘stem cells AND (cornea OR corneal) AND (endothelial OR endothelium)'. PMID:23470788

  9. Does corneal hysteresis correlate with endothelial cell density?

    PubMed

    Akova-Budak, Berna; Kıvanç, Sertaç Argun

    2015-05-21

    Our aim was to determine if there is a correlation between corneal biomechanical properties, endothelial cell count, and corneal pachymetry in healthy corneas. Ninety-two eyes of all subjects underwent complete ocular examination, including intraocular pressure measurement by Goldmann applanation tonometer, objective refraction, and slit-lamp biomicroscopy. Topographic measurements and corneal pachymetry were performed using a Scheimpflug-based (Pentacam, Oculus, Germany) corneal topographer. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured with an Ocular Response Analyzer (ORA, Reichert Ophthalmic Instruments, Buffalo, NY). Endothelial cell count measurement was done using a specular microscope (CellChek, Konan, USA). Right eye values of the subjects were taken for the study. The mean CH was 11.5±1.7 mmHg and the mean CRF was 11.2±1.4 mmHg. Mean intraocular pressure was 15.3±2.3 mmHg. The mean endothelial cell count was 2754±205 cells/mm2. No correlation was found between biomechanical properties of cornea and endothelial cell count. There was a significant positive correlation between CH, CRF, and corneal thickness (p<0.001; r=0.79). The corneal biomechanical properties significantly correlated with corneal thickness. We found no correlation between CH and CRF with the endothelial cell density in normal subjects.

  10. A fully automated cell segmentation and morphometric parameter system for quantifying corneal endothelial cell morphology.

    PubMed

    Al-Fahdawi, Shumoos; Qahwaji, Rami; Al-Waisy, Alaa S; Ipson, Stanley; Ferdousi, Maryam; Malik, Rayaz A; Brahma, Arun

    2018-07-01

    Corneal endothelial cell abnormalities may be associated with a number of corneal and systemic diseases. Damage to the endothelial cells can significantly affect corneal transparency by altering hydration of the corneal stroma, which can lead to irreversible endothelial cell pathology requiring corneal transplantation. To date, quantitative analysis of endothelial cell abnormalities has been manually performed by ophthalmologists using time consuming and highly subjective semi-automatic tools, which require an operator interaction. We developed and applied a fully-automated and real-time system, termed the Corneal Endothelium Analysis System (CEAS) for the segmentation and computation of endothelial cells in images of the human cornea obtained by in vivo corneal confocal microscopy. First, a Fast Fourier Transform (FFT) Band-pass filter is applied to reduce noise and enhance the image quality to make the cells more visible. Secondly, endothelial cell boundaries are detected using watershed transformations and Voronoi tessellations to accurately quantify the morphological parameters of the human corneal endothelial cells. The performance of the automated segmentation system was tested against manually traced ground-truth images based on a database consisting of 40 corneal confocal endothelial cell images in terms of segmentation accuracy and obtained clinical features. In addition, the robustness and efficiency of the proposed CEAS system were compared with manually obtained cell densities using a separate database of 40 images from controls (n = 11), obese subjects (n = 16) and patients with diabetes (n = 13). The Pearson correlation coefficient between automated and manual endothelial cell densities is 0.9 (p < 0.0001) and a Bland-Altman plot shows that 95% of the data are between the 2SD agreement lines. We demonstrate the effectiveness and robustness of the CEAS system, and the possibility of utilizing it in a real world clinical setting to enable rapid diagnosis and for patient follow-up, with an execution time of only 6 seconds per image. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Identification of cytomegalovirus and human herpesvirus-6 DNA in a patient with corneal endotheliitis.

    PubMed

    Yokogawa, Hideaki; Kobayashi, Akira; Yamazaki, Natsuko; Sugiyama, Kazuhisa

    2013-03-01

    To report the case of a patient with unilateral corneal endotheliitis in which both cytomegalovirus (CMV) and human herpesvirus-6 (HHV6) DNA was identified in the aqueous humor. A 67-year-old man with corneal endotheliitis OD was referred to us for decreased visual acuity. Local corneal stromal edema, pigmented keratic precipitates, a coin-shaped lesion and minimal anterior chamber reaction were observed by slit-lamp biomicroscopy. Cells with owl's eye appearance in the endothelial cell layer were observed by in vivo laser confocal microscopy. The patient had rheumatoid arthritis, which was treated by oral prednisolone and intravenous abatacept. Polymerase chain reaction analysis of aqueous humor samples detected both CMV and HHV6 DNA, but not other HHVs. Treatment with topical ganciclovir and systemic valganciclovir resulted in a clear cornea. A patient with corneal endotheliitis had both CMV and HHV6 DNA identified in the aqueous humor. Although both viruses were identified in this case, clinical manifestations resembled CMV corneal endotheliitis, and it was unclear whether HHV6 could affect the clinical course. Systemic abatacept and corticosteroid therapy might play a positive role in cases with both CMV and HHV6 DNA in this corneal endotheliitis.

  12. Study of light scattering using C-Quant® in patients with Fuchs' endothelial dystrophy: A pilot study.

    PubMed

    Castaño-Martín, B; Gros-Otero, J; Martínez, J; Teus, M

    2017-11-01

    The purpose of this study was to determine the light scattering in patients with Fuchs' endothelial dystrophy without clinically significant corneal oedema, and evaluate its relationship with endothelial cell count, corneal thickness, and corneal biomechanical parameters. The values of light scattering were measured by C-Quant ® (Oculus Optikgeräte GmbH, Germany) in 32 eyes of 17 patients diagnosed with Fuchs' endothelial dystrophy without clinically significant corneal oedema. Corneal biomechanical properties were determined using ORA (ocular response) and Corvis ST ® (tonometry). A light scattering value outside the normal range was observed in 93.8% of eyes studied. No statistically significant association (P>.05) was found between the values of the measured light scattering by C-Quant ® and endothelial count, pachymetry, or corneal biomechanical properties. In this study, changes were found in the values of light scattering values of patients with corneal Fuchs' endothelial dystrophy. This change does not appear to correlate significantly with disease severity. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. ROCK Inhibitor Enhances Adhesion and Wound Healing of Human Corneal Endothelial Cells

    PubMed Central

    Pipparelli, Aurélien; Arsenijevic, Yvan; Thuret, Gilles; Gain, Philippe

    2013-01-01

    Maintenance of corneal transparency is crucial for vision and depends mainly on the endothelium, a non-proliferative monolayer of cells covering the inner part of the cornea. When endothelial cell density falls below a critical threshold, the barrier and “pump” functions of the endothelium are compromised which results in corneal oedema and loss of visual acuity. The conventional treatment for such severe disorder is corneal graft. Unfortunately, there is a worldwide shortage of donor corneas, necessitating amelioration of tissue survival and storage after harvesting. Recently it was reported that the ROCK inhibitor Y-27632 promotes adhesion, inhibits apoptosis, increases the number of proliferating monkey corneal endothelial cells in vitro and enhance corneal endothelial wound healing both in vitro and in vivo in animal models. Using organ culture human cornea (N = 34), the effect of ROCK inhibitor was evaluated in vitro and ex vivo. Toxicity, corneal endothelial cell density, cell proliferation, apoptosis, cell morphometry, adhesion and wound healing process were evaluated by live/dead assay standard cell counting method, EdU labelling, Ki67, Caspase3, Zo-1 and Actin immunostaining. We demonstrated for the first time in human corneal endothelial cells ex vivo and in vitro, that ROCK inhibitor did not induce any toxicity effect and did not alter cell viability. ROCK inhibitor treatment did not induce human corneal endothelial cells proliferation. However, ROCK inhibitor significantly enhanced adhesion and wound healing. The present study shows that the selective ROCK inhibitor Y-27632 has no effect on human corneal endothelial cells proliferative capacities, but alters cellular behaviours. It induces changes in cell shape, increases cell adhesion and enhances wound healing ex vivo and in vitro. Its absence of toxicity, as demonstrated herein, is relevant for its use in human therapy. PMID:23626771

  14. A novel gelatin hydrogel carrier sheet for corneal endothelial transplantation.

    PubMed

    Watanabe, Ryou; Hayashi, Ryuhei; Kimura, Yu; Tanaka, Yuji; Kageyama, Tomofumi; Hara, Susumu; Tabata, Yasuhiko; Nishida, Kohji

    2011-09-01

    We examined the feasibility of using gelatin hydrogels as carrier sheets for the transplantation of cultivated corneal endothelial cells. The mechanical properties, transparency, and permeability of gelatin hydrogel sheets were compared with those of atelocollagen sheets. Immunohistochemistry (ZO-1, Na(+)/K(+)-ATPase, and N-cadherin), hematoxylin and eosin staining, and scanning electron microscopy were performed to assess the integrity of corneal endothelial cells that were cultured on gelatin hydrogel sheets. The gelatin hydrogel sheets displayed greater transparency, elastic modulus, and albumin permeability compared to those of atelocollagen sheets. The corneal endothelial cells on gelatin hydrogel sheets showed normal expression levels of ZO-1, Na(+)/K(+)-ATPase, and N-cadherin. Hematoxylin and eosin staining revealed the formation of a continuous monolayer of cells attached to the gelatin hydrogel sheet. Scanning electron microscopy observations showed that the corneal endothelial cells were arranged in a regular, mosaic, and polygonal pattern with normal cilia. These results indicate that the gelatin hydrogel sheet is a promising material to transport corneal endothelial cells during transplantation.

  15. Corneal donor tissue preparation for endothelial keratoplasty.

    PubMed

    Woodward, Maria A; Titus, Michael; Mavin, Kyle; Shtein, Roni M

    2012-06-12

    Over the past ten years, corneal transplantation surgical techniques have undergone revolutionary changes. Since its inception, traditional full thickness corneal transplantation has been the treatment to restore sight in those limited by corneal disease. Some disadvantages to this approach include a high degree of post-operative astigmatism, lack of predictable refractive outcome, and disturbance to the ocular surface. The development of Descemet's stripping endothelial keratoplasty (DSEK), transplanting only the posterior corneal stroma, Descemet's membrane, and endothelium, has dramatically changed treatment of corneal endothelial disease. DSEK is performed through a smaller incision; this technique avoids 'open sky' surgery with its risk of hemorrhage or expulsion, decreases the incidence of postoperative wound dehiscence, reduces unpredictable refractive outcomes, and may decrease the rate of transplant rejection. Initially, cornea donor posterior lamellar dissection for DSEK was performed manually resulting in variable graft thickness and damage to the delicate corneal endothelial tissue during tissue processing. Automated lamellar dissection (Descemet's stripping automated endothelial keratoplasty, DSAEK) was developed to address these issues. Automated dissection utilizes the same technology as LASIK corneal flap creation with a mechanical microkeratome blade that helps to create uniform and thin tissue grafts for DSAEK surgery with minimal corneal endothelial cell loss in tissue processing. Eye banks have been providing full thickness corneas for surgical transplantation for many years. In 2006, eye banks began to develop methodologies for supplying precut corneal tissue for endothelial keratoplasty. With the input of corneal surgeons, eye banks have developed thorough protocols to safely and effectively prepare posterior lamellar tissue for DSAEK surgery. This can be performed preoperatively at the eye bank. Research shows no significant difference in terms of the quality of the tissue or patient outcomes using eye bank precut tissue versus surgeon-prepared tissue for DSAEK surgery. For most corneal surgeons, the availability of precut DSAEK corneal tissue saves time and money, and reduces the stress of performing the donor corneal dissection in the operating room. In part because of the ability of the eye banks to provide high quality posterior lamellar corneal in a timely manner, DSAEK has become the standard of care for surgical management of corneal endothelial disease. The procedure that we are describing is the preparation of the posterior lamellar cornea at the eye bank for transplantation in DSAEK surgery (Figure 1).

  16. In vivo imaging of coin-shaped lesions in cytomegalovirus corneal endotheliitis by anterior segment optical coherence tomography.

    PubMed

    Yokogawa, Hideaki; Kobayashi, Akira; Yamazaki, Natsuko; Sugiyama, Kazuhisa

    2014-12-01

    The aim of this study was to investigate in vivo corneal changes of coin-shaped lesions in cytomegalovirus corneal endotheliitis using anterior segment optical coherence tomography (AS-OCT). Two eyes of 2 patients (69- and 71-year-old men), with polymerase chain reaction-proven CMV corneal endotheliitis presenting coin-shaped lesions, were included in this study. AS-OCT examination was performed on the initial visit and at follow-up visits by paying special attention to the coin-shaped lesions. Selected AS-OCT images of the cornea were evaluated qualitatively for changes in the shape and degree of light reflection. In both cases, coin-shaped lesions were observed at the corneal endothelial surface as clusters of fine precipitates using slit-lamp biomicroscopy. Using AS-OCT, high-resolution images of the putative coin-shaped lesions were successfully obtained in both patients as an irregularly thickened highly reflective endothelial cell layer. After anti-CMV treatment, the coin-shaped lesions were resolved as assessed by slit-lamp biomicroscopy and AS-OCT in both patients. High-resolution AS-OCT provides novel and detailed visual information of coin-shaped lesions in patients with CMV corneal endotheliitis. Visualization of coin-shaped lesions by AS-OCT may be a useful adjunct to the diagnosis and follow-up of CMV corneal endotheliitis.

  17. [Analysis of the Effect of Non-phacoemulsification Cataract Operation on Corneal Endothelial Cell Nucleus Division].

    PubMed

    Huang, Zufeng; Miao, Xiaoqing

    2015-09-01

    To investigate the effect of non-phacoemulsification cataract operation in two different patterns of nucleus delivery on the quantity and morphology of corneal endothelial cells and postoperative visual acuity. Forty patients diagnosed with cataract underwent cataract surgery and were assigned into the direct nuclear delivery and semi-nuclear delivery groups. Lens density was measured and divided into the hard and soft lenses according to Emery-little lens nucleus grading system. Non-phacoemulsification cataract operation was performed. At 3 d after surgery, the quantity and morphology of corneal endothelium were counted and observed under corneal endothelial microscope. During 3-month postoperative follow-up, the endothelial cell loss rate, morphological changes and visual acuity were compared among four groups. Corneal endothelial cell loss rate in the direct delivery of hard nucleus group significantly differed from those in the other three groups before and 3 months after operation (P < 0.01), whereas no statistical significance was found among the direct delivery of soft nucleus, semi-delivery of hard nucleus and semi-delivery soft nucleus groups (all P > 0.05). Preoperative and postoperative 2-d visual acuity did not differ between the semi-delivery of hard nucleus and direct delivery of soft nucleus groups (P = 0.49), significantly differed from those in the semi-delivery of soft nucleus (P = 0.03) and direct delivery of hard nucleus groups (P = 0.14). Visual acuity at postoperative four months did not differ among four groups (P = 0.067). During non-phacoemulsification cataract surgery, direct delivery of hard nucleus caused severe injury to corneal endothelium and semi-delivery of soft nucleus yielded mild corneal endothelial injury. Slight corneal endothelial injury exerted no apparent effect upon visual acuity and corneal endothelial morphology at three months after surgery.

  18. N-Isopropylacrylamide-co-glycidylmethacrylate as a Thermoresponsive Substrate for Corneal Endothelial Cell Sheet Engineering

    PubMed Central

    Madathil, Bernadette K.; Anil Kumar, Pallickaveedu RajanAsari; Kumary, Thrikkovil Variyath

    2014-01-01

    Endothelial keratoplasty is a recent shift in the surgical treatment of corneal endothelial dystrophies, where the dysfunctional endothelium is replaced whilst retaining the unaffected corneal layers. To overcome the limitation of donor corneal shortage, alternative use of tissue engineered constructs is being researched. Tissue constructs with intact extracellular matrix are generated using stimuli responsive polymers. In this study we evaluated the feasibility of using the thermoresponsive poly(N-isopropylacrylamide-co-glycidylmethacrylate) polymer as a culture surface to harvest viable corneal endothelial cell sheets. Incubation below the lower critical solution temperature of the polymer allowed the detachment of the intact endothelial cell sheet. Phase contrast and scanning electron microscopy revealed the intact architecture, cobble stone morphology, and cell-to-cell contact in the retrieved cell sheet. Strong extracellular matrix deposition was also observed. The RT-PCR analysis confirmed functionally active endothelial cells in the cell sheet as evidenced by the positive expression of aquaporin 1, collagen IV, Na+-K+ ATPase, and FLK-1. Na+-K+ ATPase protein expression was also visualized by immunofluorescence staining. These results suggest that the in-house developed thermoresponsive culture dish is a suitable substrate for the generation of intact corneal endothelial cell sheet towards transplantation for endothelial keratoplasty. PMID:25003113

  19. Isolated Capsulorhexis Flap Technique in Femtosecond Laser-Assisted Cataract Surgery to Protect the Corneal Endothelial Cells.

    PubMed

    Li, Shaowei; Chen, Xu; Zhao, Jun; Xu, Man; Yu, Zhouxing

    2017-12-18

    To present a novel technique that using capsulorhexis flap to protect corneal endothelial cells during femtosecond laser-assisted cataract surgery. During the procedure, an isolated capsulorhexis flap was used to lift it up carefully by using OVD until the flap attached to the corneal inner layer. It kept steady during the phaco phase, and been removed by I/A tip after intraocular lens implantation. In our pilot study, the damage to the corneal endothelial cells from the phacoemulsification procedure were no more than the traditional phaco procedure, even femtosecond laser assisted cataract surgery. Isolated capsulorhexis flap technique initiate a new approach to protect the endothelial cell. It is a simple technique with a short learning curve, but still need a further investigation to prove the protection of corneal endothelial cells.

  20. N-Acetylcysteine Increases Corneal Endothelial Cell Survival in a Mouse Model of Fuchs Endothelial Corneal Dystrophy

    PubMed Central

    Kim, Eun Chul; Meng, Huan; Jun, Albert S.

    2014-01-01

    The present study evaluated survival effects of N-acetylcysteine (NAC) on cultured corneal endothelial cells exposed to oxidative and endoplasmic reticulum (ER) stress and in a mouse model of early-onset Fuchs endothelial corneal dystrophy (FECD). Cultured bovine corneal endothelial cell viability against oxidative and ER stress was determined by CellTiter-Glo® luminescent reagent. Two-month-old homozygous knock-in Col8a2L450W/L450W mutant (L450W) and C57/Bl6 wild-type (WT) animals were divided into two groups of 15 mice. Group I received 7 mg/mL NAC in drinking water and Group II received control water for 7 months. Endothelial cell density and morphology were evaluated with confocal microscopy. Antioxidant gene (iNos) and ER stress/unfolded protein response gene (Grp78 and Chop) mRNA levels and protein expression were measured in corneal endothelium by real time PCR and Western blotting. Cell viability of H2O2 and thapsigargin exposed cells pre-treated with NAC was significantly increased compared to untreated controls (pitalic>0.01). Corneal endothelial cell density (CD) was higher (p=0.001) and percent polymegathism was lower (p=0.04) in NAC treated L450W mice than in untreated L450W mice. NAC treated L450W endothelium showed significant upregulation of iNos, whereas Grp78 and Chop were downregulated compared to untreated L450W endothelium by real time PCR and Western blotting. NAC increases survival in cultured corneal endothelial cells exposed against ER and oxidative stress. Systemic NAC ingestion increases corneal endothelial cell survival which is associated with increased antioxidant and decreased ER stress markers in a mouse model of early-onset FECD. Our study presents in vivo evidence of a novel potential medical treatment for FECD. PMID:24952277

  1. N-Acetylcysteine increases corneal endothelial cell survival in a mouse model of Fuchs endothelial corneal dystrophy.

    PubMed

    Kim, Eun Chul; Meng, Huan; Jun, Albert S

    2014-10-01

    The present study evaluated survival effects of N-acetylcysteine (NAC) on cultured corneal endothelial cells exposed to oxidative and endoplasmic reticulum (ER) stress and in a mouse model of early-onset Fuchs endothelial corneal dystrophy (FECD). Cultured bovine corneal endothelial cell viability against oxidative and ER stress was determined by CellTiter-Glo(®) luminescent reagent. Two-month-old homozygous knock-in Col8a2(L450W/L450W) mutant (L450W) and C57/Bl6 wild-type (WT) animals were divided into two groups of 15 mice. Group I received 7 mg/mL NAC in drinking water and Group II received control water for 7 months. Endothelial cell density and morphology were evaluated with confocal microscopy. Antioxidant gene (iNos) and ER stress/unfolded protein response gene (Grp78 and Chop) mRNA levels and protein expression were measured in corneal endothelium by real time PCR and Western blotting. Cell viability of H2O2 and thapsigargin exposed cells pre-treated with NAC was significantly increased compared to untreated controls (p < 0.01). Corneal endothelial cell density (CD) was higher (p = 0.001) and percent polymegathism was lower (p = 0.04) in NAC treated L450W mice than in untreated L450W mice. NAC treated L450W endothelium showed significant upregulation of iNos, whereas Grp78 and Chop were downregulated compared to untreated L450W endothelium by real time PCR and Western blotting. NAC increases survival in cultured corneal endothelial cells exposed against ER and oxidative stress. Systemic NAC ingestion increases corneal endothelial cell survival which is associated with increased antioxidant and decreased ER stress markers in a mouse model of early-onset FECD. Our study presents in vivo evidence of a novel potential medical treatment for FECD. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Evaluation of intracameral injection of ranibizumab and bevacizumab on the corneal endothelium by scanning electron microscopy.

    PubMed

    Ari, Seyhmus; Nergiz, Yusuf; Aksit, Ihsan; Sahin, Alparslan; Cingu, Kursat; Caca, Ihsan

    2015-03-01

    To evaluate the effects of intracameral injection of ranibizumab and bevacizumab on the corneal endothelium by scanning electron microscopy (SEM). Twenty-eight female rabbits were randomly divided into four equal groups. Rabbits in groups 1 and 2 underwent intracameral injection of 1 mg/0.1 mL and 0.5 mg/0.05 mL ranibizumab, respectively; group 3 was injected with 1.25 mg/0.05 mL bevacizumab. All three groups were injected with a balanced salt solution (BSS) into the anterior chamber of the left (fellow) eye. None of the rabbits in group 4 underwent an injection. Corneal thickness and intraocular pressure were measured before the injections, on the first day, and in the first month after injection. The rabbits were sacrificed and corneal tissues were excised in the first month after injection. Specular microscopy was used for the corneal endothelial cell count. Endothelial cell density was assessed and comparisons drawn between the groups and the control. Micrographs were recorded for SEM examination. The structure of the corneal endothelial cells, the junctional area of the cell membrane, the distribution of microvillus, and the cell morphology of the eyes that underwent intracameral injection of vascular endothelial growth factor (VEGF), BSS, and the control group were compared. Corneal thickness and intraocular pressure were not significantly different between the groups that underwent anti-VEGF or BSS injection and the control group on the first day and in the first month of injection. The corneal endothelial cell count was significantly diminished in all three groups; predominantly in group 1 and 2 (P<0.05). The SEM examination revealed normal corneal endothelial histology in group 3 and the control group. Eyes in group 1 exhibited indistinctness of corneal endothelial cell borders, microvillus loss in the luminal surface, excessive blebbing, and disintegration of intercellular junctions. In group 2, the cell structure of the corneal endothelium and intercellular junctions were normal. However, a relative reduction was observed in the microvillus density of endothelial cells. Although eyes in group 3 were morphologically similar to fellow eyes and the control group, disarrangement in endothelial cell borders was evident. The SEM examination pointed out deterioration in endothelial cell morphology after intracameral injection of 1 and 0.5 mg ranizumab. However, the effects of intracameral bevacizumab injection on corneal endothelial cells were similar to those found in fellow eyes and the control group. Further large-scale studies that examine the cellular changes by transmission electron microscopy are required to support the results of the present study that evaluates the structural changes in endothelial cells by SEM.

  3. Optimization of human corneal endothelial cell culture: density dependency of successful cultures in vitro.

    PubMed

    Peh, Gary S L; Toh, Kah-Peng; Ang, Heng-Pei; Seah, Xin-Yi; George, Benjamin L; Mehta, Jodhbir S

    2013-05-03

    Global shortage of donor corneas greatly restricts the numbers of corneal transplantations performed yearly. Limited ex vivo expansion of primary human corneal endothelial cells is possible, and a considerable clinical interest exists for development of tissue-engineered constructs using cultivated corneal endothelial cells. The objective of this study was to investigate the density-dependent growth of human corneal endothelial cells isolated from paired donor corneas and to elucidate an optimal seeding density for their extended expansion in vitro whilst maintaining their unique cellular morphology. Established primary human corneal endothelial cells were propagated to the second passage (P2) before they were utilized for this study. Confluent P2 cells were dissociated and seeded at four seeding densities: 2,500 cells per cm2 ('LOW'); 5,000 cells per cm2 ('MID'); 10,000 cells per cm2 ('HIGH'); and 20,000 cells per cm2 ('HIGH(×2)'), and subsequently analyzed for their propensity to proliferate. They were also subjected to morphometric analyses comparing cell sizes, coefficient of variance, as well as cell circularity when each culture became confluent. At the two lower densities, proliferation rates were higher than cells seeded at higher densities, though not statistically significant. However, corneal endothelial cells seeded at lower densities were significantly larger in size, heterogeneous in shape and less circular (fibroblastic-like), and remained hypertrophic after one month in culture. Comparatively, cells seeded at higher densities were significantly homogeneous, compact and circular at confluence. Potentially, at an optimal seeding density of 10,000 cells per cm2, it is possible to obtain between 10 million to 25 million cells at the third passage. More importantly, these expanded human corneal endothelial cells retained their unique cellular morphology. Our results demonstrated a density dependency in the culture of primary human corneal endothelial cells. Sub-optimal seeding density results in a decrease in cell saturation density, as well as a loss in their proliferative potential. As such, we propose a seeding density of not less than 10,000 cells per cm2 for regular passage of primary human corneal endothelial cells.

  4. Expansion and cryopreservation of porcine and human corneal endothelial cells.

    PubMed

    Marquez-Curtis, Leah A; McGann, Locksley E; Elliott, Janet A W

    2017-08-01

    Impairment of the corneal endothelium causes blindness that afflicts millions worldwide and constitutes the most often cited indication for corneal transplants. The scarcity of donor corneas has prompted the alternative use of tissue-engineered grafts which requires the ex vivo expansion and cryopreservation of corneal endothelial cells. The aims of this study are to culture and identify the conditions that will yield viable and functional corneal endothelial cells after cryopreservation. Previously, using human umbilical vein endothelial cells (HUVECs), we employed a systematic approach to optimize the post-thaw recovery of cells with high membrane integrity and functionality. Here, we investigated whether improved protocols for HUVECs translate to the cryopreservation of corneal endothelial cells, despite the differences in function and embryonic origin of these cell types. First, we isolated endothelial cells from pig corneas and then applied an interrupted slow cooling protocol in the presence of dimethyl sulfoxide (Me 2 SO), with or without hydroxyethyl starch (HES). Next, we isolated and expanded endothelial cells from human corneas and applied the best protocol verified using porcine cells. We found that slow cooling at 1 °C/min in the presence of 5% Me 2 SO and 6% HES, followed by rapid thawing after liquid nitrogen storage, yields membrane-intact cells that could form monolayers expressing the tight junction marker ZO-1 and cytoskeleton F-actin, and could form tubes in reconstituted basement membrane matrix. Thus, we show that a cryopreservation protocol optimized for HUVECs can be applied successfully to corneal endothelial cells, and this could provide a means to address the need for off-the-shelf cryopreserved cells for corneal tissue engineering and regenerative medicine. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Patients with Dry Eye Disease and Low Subbasal Nerve Density are at High Risk for an Accelerated Corneal Endothelial Cell Loss

    PubMed Central

    Kheirkhah, Ahmad; Satitpitakul, Vannarut; Hamrah, Pedram; Dana, Reza

    2016-01-01

    Purpose To evaluate the changes in corneal endothelial cell density (CECD) over time in patients with dry eye disease (DED) and to correlate the endothelial cell loss with corneal subbasal nerve density. Methods This retrospective study included 40 eyes of 20 patients with DED. Laser in vivo confocal microscopy had been performed in the central cornea of both eyes at an initial visit and repeated after a mean follow-up of 33.2 ± 10.2 months. The densities of corneal endothelial cells and subbasal nerves were measured in both visits and compared with 13 eyes of 13 normal age-matched controls. Results At the initial visit, the DED group had lower densities of corneal endothelial cells (2620 ± 386 cells/mm2) and subbasal nerves (17.8 ± 7.5 mm/mm2) compared with the control group (2861 ± 292 cells/mm2 and 22.8 ± 3.0 mm/mm2, with P=0.08 and P=0.01, respectively). At the end of follow-up, although there was no significant change in subbasal nerve density (16.7 ± 7.2 mm/mm2, P=0.43), the mean CECD significantly decreased to 2465 ± 391 cells/mm2 (P=0.01), with a mean corneal endothelial cell loss of 2.1 ± 3.6% per year. The endothelial cell loss showed a statistically significant negative correlation with the initial subbasal nerve density (Rs= −0.55, P=0.02). Conclusion Patients with DED have an accelerated corneal endothelial cell loss which is more than what has been reported in the literature for normal aging. Those with lower subbasal nerve density, in particular, are at a higher risk for endothelial cell loss over time. PMID:28060067

  6. Long-term corneal endothelial cell changes in pediatric intraocular lens reposition and exchange cases.

    PubMed

    Wang, Yan; Wu, Mingxing; Zhu, Liyuan; Liu, Yizhi

    2012-04-01

    To evaluate long-term corneal endothelial cell changes of intraocular lens (IOL) reposition and exchange in children. State key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, 510060, China In this retrospective study, all IOL reposition and exchange procedures performed in patients under 14 years old between January 1999 and April 2009 were included. Follow-up outcomes included corneal endothelial cell density, hexagonality, coefficient of variance, average cell size. IOL reposition procedures in 12 eyes (12 cases) (reposition group, RPG), and IOL exchanges in eight eyes (eight cases) (exchange group, EXG) were performed because of IOL pupillary capture or IOL dislocation. Median of follow-up was 44.5 months in RPG and 66.2 months in EXG. The density of corneal endothelial cells in RPG (2,053 ± 493/mm(2)) and EXG (2,100 ± 758/mm(2)) was significantly decreased in comparison to the control eyes (3,116 ± 335/mm(2)). Hexagonality of corneal endothelial cells and coefficient of variance showed no difference among the control group, RPG and EXG (P > 0.05). The density of corneal endothelial cells was conspicuously decreased after IOL reposition or exchange procedures in childhood cases. Longer follow-up must be conducted in these cases.

  7. Corneal endothelial dysfunction in Pearson syndrome.

    PubMed

    Kasbekar, Shivani A; Gonzalez-Martin, Jose A; Shafiq, Ayad E; Chandna, Arvind; Willoughby, Colin E

    2013-01-01

    Mitochondrial disorders are associated with well recognized ocular manifestations. Pearson syndrome is an often fatal, multisystem, mitochondrial disorder that causes variable bone marrow, hepatic, renal and pancreatic exocrine dysfunction. Phenotypic progression of ocular disease in a 12-year-old male with Pearson syndrome is described. This case illustrates phenotypic drift from Pearson syndrome to Kearns-Sayre syndrome given the patient's longevity. Persistent corneal endothelial failure was noted in addition to ptosis, chronic external ophthalmoplegia and mid-peripheral pigmentary retinopathy. We propose that corneal edema resulting from corneal endothelial metabolic pump failure occurs within a spectrum of mitochondrial disorders.

  8. NaK-ATPase pump sites in cultured bovine corneal endothelium of varying cell density at confluence.

    PubMed

    Crawford, K M; Ernst, S A; Meyer, R F; MacCallum, D K

    1995-06-01

    The driving force for ion and water flow necessary for efficient deturgesence of the corneal stroma resides in the ouabain-sensitive sodium (Na) pump of corneal endothelial cells. Using a cell culture model of corneal endothelial cell hypertrophy, the authors examined the expression of Na pumps at the cell surface to see how this central element of the endothelial pump changed as corneal endothelial cell density decreased to a level associated with corneal decompensation in vivo. 3H-ouabain binding to NaK-ATPase at saturating conditions was used to quantitate the number of Na pump sites on cultured bovine corneal endothelial cells as the confluent density decreased from approximately 2750 cells/mm2 to approximately 275 cells/mm2. The mean number of Na pump sites per cell at confluence (1.92 +/- 0.07 x 10(6)) did not change as the cell density decreased 2.7-fold from 2763 cells/mm2 to 1000 cells/mm2. However, pump site expression doubled to approximately 4 x 10(6) sites/cell as the cell density decreased from 1000 cells/mm2 to 275 cells/mm2. Despite the incremental increase in Na pump site expression that occurred as the cells hypertrophied below a density of 1000/mm2 to achieve confluence, this increase was insufficient to prevent a decrease in Na pump site density of the intact monolayer, expressed as pump sites/mm2. The confluent cell density of cultured bovine corneal endothelial cells can be varied from that found in the normal native cornea to that associated with corneal decompensation. In confluent cultures with cell densities ranging from 2750 cells/mm2 to 1000 cells/mm2, the number of pump sites per cell remains relatively unchanged. Below cell densities of 1000 cells/mm2, the number of pump sites per cell progressively increases. The increased Na pump site abundance in markedly hypertrophied endothelial cells cannot adequately compensate for the progressive reduction in the number of transporting cells per unit area within the intact monolayer. Even when considered with the decrease in the size of the paracellular ion conductive pathway that is a consequence of progressive endothelial hypertrophy, the overall pumping capacity of the intact endothelial monolayer declines.

  9. Investigation of Overrun-Processed Porous Hyaluronic Acid Carriers in Corneal Endothelial Tissue Engineering

    PubMed Central

    Lai, Jui-Yang; Cheng, Hsiao-Yun; Ma, David Hui-Kang

    2015-01-01

    Hyaluronic acid (HA) is a linear polysaccharide naturally found in the eye and therefore is one of the most promising biomaterials for corneal endothelial regenerative medicine. This study reports, for the first time, the development of overrun-processed porous HA hydrogels for corneal endothelial cell (CEC) sheet transplantation and tissue engineering applications. The hydrogel carriers were characterized to examine their structures and functions. Evaluations of carbodiimide cross-linked air-dried and freeze-dried HA samples were conducted simultaneously for comparison. The results indicated that during the fabrication of freeze-dried HA discs, a technique of introducing gas bubbles in the aqueous biopolymer solutions can be used to enlarge pore structure and prevent dense surface skin formation. Among all the groups studied, the overrun-processed porous HA carriers show the greatest biological stability, the highest freezable water content and glucose permeability, and the minimized adverse effects on ionic pump function of rabbit CECs. After transfer and attachment of bioengineered CEC sheets to the overrun-processed HA hydrogel carriers, the therapeutic efficacy of cell/biopolymer constructs was tested using a rabbit model with corneal endothelial dysfunction. Clinical observations including slit-lamp biomicroscopy, specular microscopy, and corneal thickness measurements showed that the construct implants can regenerate corneal endothelium and restore corneal transparency at 4 weeks postoperatively. Our findings suggest that cell sheet transplantation using overrun-processed porous HA hydrogels offers a new way to reconstruct the posterior corneal surface and improve endothelial tissue function. PMID:26296087

  10. Screening and Characterization of Drugs That Protect Corneal Endothelial Cells Against Unfolded Protein Response and Oxidative Stress

    PubMed Central

    Kim, Eun Chul; Toyono, Tetsuya; Berlinicke, Cynthia A.; Zack, Donald J.; Jurkunas, Ula; Usui, Tomohiko; Jun, Albert S.

    2017-01-01

    Purpose To screen for and characterize compounds that protect corneal endothelial cells against unfolded protein response (UPR) and oxidative stress. Methods Bovine corneal endothelial cells (BCECs) were treated for 48 hours with 640 compounds from a Food and Drug Administration (FDA)-approved drug library and then challenged with thapsigargin or H2O2 to induce UPR or oxidative stress, respectively. Cell viability was measured using the CellTiter-Glo survival assay. Selected “hits” were subjected to further dose-response testing, and their ability to modulate expression of UPR and oxidative stress markers was assessed by RT-PCR, Western blot, and measurement of protein carbonyl and 8-hydroxydeoxyguanosine (8-OHdG) adducts in immortalized human corneal endothelial cells (iHCECs). Results Forty-one drugs at 20 μM and 55 drugs at 100 μM increased survival of H2O2-challenged cells, and 8 drugs at 20 μM and 2 drugs at 100 μM increased survival of thapsigargin-challenged cells, compared with untreated control cells. Nicergoline, ergothioneine, nimesulide, oxotremorine, and mefenamic acid increased survival of both H2O2- and thapsigargin-challenged cells. Oxotremorine altered DNA damage inducible 3 (CHOP) gene expression, glucose-regulated protein 78 kDa (GRP78) and activating transcription factor 4 (ATF4) protein expression, and protein carbonyl and 8-OHdG levels. Mefenamic acid altered GRP78 protein expression and protein carbonyl and 8-OHdG levels. Conclusions Oxotremorine and mefenamic acid are potential survival factors for corneal endothelial cells under UPR and oxidative stress. The described assay can be further expanded to screen additional drugs for potential therapeutic effect in corneal endothelial diseases such as Fuchs' endothelial corneal dystrophy. PMID:28159976

  11. Screening and Characterization of Drugs That Protect Corneal Endothelial Cells Against Unfolded Protein Response and Oxidative Stress.

    PubMed

    Kim, Eun Chul; Toyono, Tetsuya; Berlinicke, Cynthia A; Zack, Donald J; Jurkunas, Ula; Usui, Tomohiko; Jun, Albert S

    2017-02-01

    To screen for and characterize compounds that protect corneal endothelial cells against unfolded protein response (UPR) and oxidative stress. Bovine corneal endothelial cells (BCECs) were treated for 48 hours with 640 compounds from a Food and Drug Administration (FDA)-approved drug library and then challenged with thapsigargin or H2O2 to induce UPR or oxidative stress, respectively. Cell viability was measured using the CellTiter-Glo survival assay. Selected "hits" were subjected to further dose-response testing, and their ability to modulate expression of UPR and oxidative stress markers was assessed by RT-PCR, Western blot, and measurement of protein carbonyl and 8-hydroxydeoxyguanosine (8-OHdG) adducts in immortalized human corneal endothelial cells (iHCECs). Forty-one drugs at 20 μM and 55 drugs at 100 μM increased survival of H2O2-challenged cells, and 8 drugs at 20 μM and 2 drugs at 100 μM increased survival of thapsigargin-challenged cells, compared with untreated control cells. Nicergoline, ergothioneine, nimesulide, oxotremorine, and mefenamic acid increased survival of both H2O2- and thapsigargin-challenged cells. Oxotremorine altered DNA damage inducible 3 (CHOP) gene expression, glucose-regulated protein 78 kDa (GRP78) and activating transcription factor 4 (ATF4) protein expression, and protein carbonyl and 8-OHdG levels. Mefenamic acid altered GRP78 protein expression and protein carbonyl and 8-OHdG levels. Oxotremorine and mefenamic acid are potential survival factors for corneal endothelial cells under UPR and oxidative stress. The described assay can be further expanded to screen additional drugs for potential therapeutic effect in corneal endothelial diseases such as Fuchs' endothelial corneal dystrophy.

  12. Influence of Pre-Freezing Temperature on the Corneal Endothelial Cytocompatibility and Cell Delivery Performance of Porous Hyaluronic Acid Hydrogel Carriers.

    PubMed

    Lai, Jui-Yang

    2015-08-11

    The development of porous hyaluronic acid (HA) hydrogels for corneal endothelial tissue engineering is attractive because they can be used as functional cell delivery carriers to help in the reconstruction of damaged areas. The purpose of this study was to investigate the corneal endothelial cytocompatibility and cell delivery performance of porous HA hydrogel biomaterials fabricated at different pre-freezing temperatures. As compared to their counterparts prepared at -80 °C, the HA samples fabricated at higher pre-freezing temperature (i.e., 0 °C) exhibited a larger pore size and higher porosity, thereby leading to lower resistance to glucose permeation. Live/dead assays and gene expression analyses showed that the restricted porous structure of HA carriers decreases the viability and ionic pump function of cultured corneal endothelial cells (CECs). The results also indicated that the porous hydrogel biomaterials fabricated at high pre-freezing temperature seem to be more compatible with rabbit CECs. In an animal model of corneal endothelial dysfunction, the wounded rabbit corneas receiving bioengineered CEC sheets and restricted porous-structured HA carriers demonstrated poor tissue reconstruction. The therapeutic efficacy of cell sheet transplants can be improved by using carrier materials prepared at high pre-freezing temperature. Our findings suggest that the cryogenic operation temperature-mediated pore microstructure of HA carriers plays an important role in corneal endothelial cytocompatibility and cell delivery performance.

  13. Coupling of HRT II and AS-OCT to evaluate corneal endothelial cell loss and in vivo visualization of the Ahmed glaucoma valve implant.

    PubMed

    Mendrinos, E; Dosso, A; Sommerhalder, J; Shaarawy, T

    2009-09-01

    To report corneal endothelial cell loss and in vivo visualization of the Ahmed glaucoma valve implant in eyes with refractory glaucoma. Ten eyes underwent Ahmed valve implant surgery and were followed-up for 12 months. Data collected included intraocular pressure (IOP), number of antiglaucoma medications and surgery-related complications. At 6 and 12 months postoperatively, the intracameral length of the drainage tube (ICL) and the distance between the tube and the cornea (T-C distance), and the iris (T-I distance) were assessed using anterior segment optical coherence tomography (AS-OCT). Heidelberg cornea tomograph II (HRT II) was used to measure the corneal endothelial cell density. Mean (+/-SEM) preoperative IOP was 29.5+/-4 mmHg. Mean postoperative IOP was 11.6+/-2 at 12 months (P<0.01). Over a 6-month period, mean corneal endothelial loss was 7.9%+/-2.5 in the central and 7.5%+/-2.4 in the peripheral cornea (P<0.01). There was no correlation between central or peripheral corneal endothelial cell loss and the T-C, T-I distance or the ICL of the tube. Corneal endothelial cell loss occurs following Ahmed valve implant surgery, this appears to be multifactorial. AS-OCT and HRT II are promising methods for the follow-up of patients with a glaucoma drainage device.

  14. Ribonuclease 5 facilitates corneal endothelial wound healing via activation of PI3-kinase/Akt pathway

    PubMed Central

    Kim, Kyoung Woo; Park, Soo Hyun; Lee, Soo Jin; Kim, Jae Chan

    2016-01-01

    To maintain corneal transparency, corneal endothelial cells (CECs) exert a pump function against aqueous inflow. However, human CECs are arrested in the G1-phase and non-proliferative in vivo. Thus, treatment of corneal endothelial decompensation is limited to corneal transplantation, and grafts are vulnerable to immune rejection. Here, we show that ribonuclease (RNase) 5 is more highly expressed in normal human CECs compared to decompensated tissues. Furthermore, RNase 5 up-regulated survival of CECs and accelerated corneal endothelial wound healing in an in vitro wound of human CECs and an in vivo cryo-damaged rabbit model. RNase 5 treatment rapidly induced accumulation of cytoplasmic RNase 5 into the nucleus, and activated PI3-kinase/Akt pathway in human CECs. Moreover, inhibition of nuclear translocation of RNase 5 using neomycin reversed RNase 5-induced Akt activation. As a potential strategy for proliferation enhancement, RNase 5 increased the population of 5-bromo-2′-deoxyuridine (BrdU)-incorporated proliferating CECs with concomitant PI3-kinase/Akt activation, especially in CECs deprived of contact-inhibition. Specifically, RNase 5 suppressed p27 and up-regulated cyclin D1, D3, and E by activating PI3-kinase/Akt in CECs to initiate cell cycle progression. Together, our data indicate that RNase 5 facilitates corneal endothelial wound healing, and identify RNase 5 as a novel target for therapeutic exploitation. PMID:27526633

  15. Corneal status in primary angle-closure glaucoma with a history of acute attack.

    PubMed

    Chen, Mei-Ju; Liu, Catherine Jui-Ling; Cheng, Ching-Yu; Lee, Shui-Mei

    2012-01-01

    The corneal status of patients with primary angle-closure glaucoma (PACG) with a history of acute attack was investigated. This cross-sectional study included 40 eyes of PACG patients with an earlier documented symptomatic acute angle-closure attack (aPACG), 40 uninvolved fellow eyes of aPACG patients (fPACG), 44 eyes of chronic PACG patients without such a history (cPACG), and 50 eyes of age-matched normal participants. All glaucoma patients had patent peripheral iridotomies with adequate intraocular pressure control. The examinations and recorded parameters included visual acuity, intraocular pressure, gonioscopy, vertical cup-to-disc ratio, specular microscopy, central corneal pachymetry, refraction, corneal curvature radius, anterior chamber depth, axial length, and lens thickness measurements, and the presenting intraocular pressure and the duration of acute angle-closure attack for aPACG eyes. The mean endothelial cell density was 2271±80 cells/mm(2) in aPACG, 2458±79 cells/mm(2) in fPACG, 2379±50 cells/mm(2) in cPACG, and 2559±45 cells/mm(2) in controls. The aPACG eyes had significantly lower endothelial cell density compared with normal eyes (P=0.002). There was no significant difference in endothelial cell density of aPACG eyes compared with fPACG or cPACG eyes. Multivariate analysis showed the duration of the acute attack was the only factor independently associated with corneal endothelial density of aPACG eyes. The mean central corneal thickness of aPACG (549±32 μm) did not differ significantly from control eyes (552±27 μm), cPACG (557±32 μm), and fPACG (553±31 μm) (P=0.911, 0.274, and 0.725, respectively). Corneal curvature radius of aPACG eyes was not significantly different from that of the comparison groups (all P>0.05). Corneal endothelial cell density was significantly reduced in aPACG eyes compared with normal eyes. No significant difference in endothelial cell density of aPACG eyes was noted when compared with fPACG or cPACG eyes. Corneal endothelial cell density was negatively associated with the duration of the acute attack, but was not associated with demographic and biometric characteristics. Central corneal thickness and corneal curvature radius were not associated with an earlier acute angle-closure attack.

  16. Confocal microscopy and electrophysiological study of single patient corneal endothelium cell cultures

    NASA Astrophysics Data System (ADS)

    Tatini, Francesca; Rossi, Francesca; Coppi, Elisabetta; Magni, Giada; Fusco, Irene; Menabuoni, Luca; Pedata, Felicita; Pugliese, Anna Maria; Pini, Roberto

    2016-04-01

    The characterization of the ion channels in corneal endothelial cells and the elucidation of their involvement in corneal pathologies would lead to the identification of new molecular target for pharmacological treatments and to the clarification of corneal physiology. The corneal endothelium is an amitotic cell monolayer with a major role in preserving corneal transparency and in regulating the water and solute flux across the posterior surface of the cornea. Although endothelial cells are non-excitable, they express a range of ion channels, such as voltage-dependent Na+ channels and K+ channels, L-type Ca2 channels and many others. Interestingly, purinergic receptors have been linked to a variety of conditions within the eye but their presence in the endothelium and their role in its pathophysiology is still uncertain. In this study, we were able to extract endothelial cells from single human corneas, thus obtaining primary cultures that represent the peculiarity of each donor. Corneas were from tissues not suitable for transplant in patients. We characterized the endothelial cells by confocal microscopy, both within the intact cornea and in the primary endothelial cells cultures. We also studied the functional role of the purinergic system (adenosine, ATP and their receptors) by means of electrophysiological recordings. The experiments were performed by patch clamp recordings and confocal time-lapse microscopy and our results indicate that the application of purinergic compounds modulates the amplitude of outward currents in the isolated endothelial cells. These findings may lead to the proposal of new therapies for endothelium-related corneal diseases.

  17. Effects of SOV-induced phosphatase inhibition and expression of protein tyrosine phosphatases in rat corneal endothelial cells.

    PubMed

    Chen, Wei-Li; Harris, Deshea L; Joyce, Nancy C

    2005-11-01

    Contact inhibition is an important mechanism for maintaining corneal endothelium in a non-replicative state. Protein tyrosine phosphatases (PTPs) play a role in regulating the integrity of cell-cell contacts, differentiation, and growth. In this study, we aimed to evaluate whether phosphatases are involved in the maintenance of contact-dependent inhibition of proliferation in corneal endothelial cells and to identify candidate PTPs that are expressed in these cells and might be involved in regulation of contact inhibition. Confluent cultures of rat corneal endothelial cells or endothelium in ex vivo corneas were treated with the general phosphatase inhibitor, sodium orthovanadate (SOV). Immunocytochemistry (ICC) evaluated the effect of SOV on cell-cell contacts by staining for ZO-1, and on cell cycle progression by staining for Ki67. Transverse sections of rat cornea and cultured rat corneal endothelial cells were used to test for expression of the candidate PTPs: PTP-mu, PTP-LAR, PTP1B, SHP-1, SHP-2, and PTEN using ICC and either Western blots or RT-PCR. ZO-1 staining demonstrated that SOV induced a time-dependent release of cell-cell contacts in confluent cultures of corneal endothelial cells and in the endothelium of ex vivo corneas. Staining for Ki67 indicated that SOV promoted limited cell cycle progression in the absence of serum. PTP-mu, PTP1B, SHP-1, SHP-2, and PTEN, but not PTP-LAR, were expressed in rat corneal endothelial cells in situ and in culture. The subcellular location of PTP-mu and PTP1B differed in subconfluent and confluent cells, while that of SHP-1, SHP-2, and PTEN was similar, regardless of confluent status. Western blots confirmed the expression of PTP1B, SHP-1, SHP-2, and PTEN. RT-PCR confirmed expression of PTP-mu mRNA. Phosphatases are involved in regulation of junctional integrity and of cell proliferation in corneal endothelial cells. PTP-mu, PTP1B, SHP-1, SHP-2, and PTEN are expressed in rat corneal endothelium and may be involved in regulation of contact inhibition in these normally non-proliferating cells.

  18. Borate transporter SLC4A11 mutations cause both Harboyan syndrome and non‐syndromic corneal endothelial dystrophy

    PubMed Central

    Desir, Julie; Moya, Graciela; Reish, Orit; Van Regemorter, Nicole; Deconinck, Hilde; David, Karen L; Meire, Françoise M; Abramowicz, Marc J

    2007-01-01

    Harboyan syndrome, or corneal dystrophy and perceptive deafness (CDPD), consists of congenital corneal endothelial dystrophy and progressive perceptive deafness, and is transmitted as an autosomal recessive trait. CDPD and autosomal recessive, non‐syndromic congenital hereditary endothelial corneal dystrophy (CHED2) both map at overlapping loci at 20p13, and mutations of SLC4A11 were reported recently in CHED2. A genotype study on six families with CDPD and on one family with either CHED or CDPD, from various ethnic backgrounds (in the seventh family, hearing loss could not be assessed because of the proband's young age), is reported here. Novel SLC4A11 mutations were found in all patients. Why some mutations cause hearing loss in addition to corneal dystrophy is presently unclear. These findings extend the implication of the SLC4A11 borate transporter beyond corneal dystrophy to perceptive deafness. PMID:17220209

  19. Atypical Presentation of Iridocorneal Endothelial Syndrome With Band Keratopathy but No Corneal Edema Managed With Descemet Membrane Endothelial Keratoplasty.

    PubMed

    Zygoura, Vasiliki; Lavy, Itay; Verdijk, Robert M; Santander-García, Diana; Baydoun, Lamis; Dapena, Isabel; Melles, Gerrit R J

    2018-04-17

    To report an unusual presentation of iridocorneal endothelial (ICE) syndrome associated with band keratopathy and its management with ethylenediamine-tetraacetic acid (EDTA) chelation and Descemet membrane endothelial keratoplasty (DMEK). A 57-year-old female patient presented with unilateral progressive painless visual impairment, corneal band keratopathy, and morphological corneal endothelial changes without corneal edema or any previous ophthalmic, medical, or family history. Routine specular and confocal microscopy imaging, as well as biomicroscopy, best-corrected visual acuity, and pachymetry measurements were performed before and after the surgical procedures. Histopathologic and immunohistochemical evaluations of the surgically excised diseased DM-endothelium were performed. Superficial epithelial keratectomy with EDTA chelation was performed. After an initial period of a few months of corneal clearance, the patient presented with recurrence of visually significant band keratopathy. After 1 year, she underwent retreatment with superficial epithelial keratectomy and EDTA chelation, followed by DMEK. Histopathologic and immunohistochemical analysis showed ICE syndrome. Two years after DMEK surgery, the cornea was still clear and band keratopathy had not recurred. To the best of our knowledge, this is the first case in the literature that reports the association of ICE syndrome with band keratopathy. As band keratopathy recurred shortly after EDTA chelation, endothelial keratoplasty (DMEK) may be indicated to successfully treat such cases.

  20. A Cost-Minimization Analysis of Tissue-Engineered Constructs for Corneal Endothelial Transplantation

    PubMed Central

    Tan, Tien-En; Peh, Gary S. L.; George, Benjamin L.; Cajucom-Uy, Howard Y.; Dong, Di; Finkelstein, Eric A.; Mehta, Jodhbir S.

    2014-01-01

    Corneal endothelial transplantation or endothelial keratoplasty has become the preferred choice of transplantation for patients with corneal blindness due to endothelial dysfunction. Currently, there is a worldwide shortage of transplantable tissue, and demand is expected to increase further with aging populations. Tissue-engineered alternatives are being developed, and are likely to be available soon. However, the cost of these constructs may impair their widespread use. A cost-minimization analysis comparing tissue-engineered constructs to donor tissue procured from eye banks for endothelial keratoplasty was performed. Both initial investment costs and recurring costs were considered in the analysis to arrive at a final tissue cost per transplant. The clinical outcomes of endothelial keratoplasty with tissue-engineered constructs and with donor tissue procured from eye banks were assumed to be equivalent. One-way and probabilistic sensitivity analyses were performed to simulate various possible scenarios, and to determine the robustness of the results. A tissue engineering strategy was cheaper in both investment cost and recurring cost. Tissue-engineered constructs for endothelial keratoplasty could be produced at a cost of US$880 per transplant. In contrast, utilizing donor tissue procured from eye banks for endothelial keratoplasty required US$3,710 per transplant. Sensitivity analyses performed further support the results of this cost-minimization analysis across a wide range of possible scenarios. The use of tissue-engineered constructs for endothelial keratoplasty could potentially increase the supply of transplantable tissue and bring the costs of corneal endothelial transplantation down, making this intervention accessible to a larger group of patients. Tissue-engineering strategies for corneal epithelial constructs or other tissue types, such as pancreatic islet cells, should also be subject to similar pharmacoeconomic analyses. PMID:24949869

  1. Endothelial cell density after photorefractive keratectomy for moderate myopia using a 213 nm solid-state laser system.

    PubMed

    Tsiklis, Nikolaos S; Kymionis, George D; Pallikaris, Aristofanis I; Diakonis, Vasilios F; Ginis, Harilaos S; Kounis, George A; Panagopoulou, Sophia I; Pallikaris, Ioannis G

    2007-11-01

    To evaluate whether photorefractive keratectomy (PRK) for moderate myopia using a solid-state laser with a wavelength of 213 nm alters the corneal endothelial cell density. University refractive surgery center. The corneal endothelium was analyzed preoperatively and 1, 6, and 12 months postoperatively using corneal confocal microscopy (modified HRT II with a Rostock Cornea Module, Heidelberg Engineering) in 60 eyes (30 patients). Patients were randomized to have myopic PRK using a 213 nm wavelength solid-state laser (study group) or a conventional 193 nm wavelength excimer laser (control group). Three endothelial images were acquired in each of 30 preoperative normal eyes to evaluate the repeatability of endothelial cell density measurements. Repeated-measures analysis of variance was used to compare the variations in endothelial cell density between the 2 lasers and the changes in endothelial cell density over time. There were no statistically significant differences in sex, age, corneal pachymetry, attempted correction, preoperative endothelial cell density, or postoperative refractive outcomes (uncorrected visual acuity, best spectacle-corrected visual acuity, and spherical equivalent refraction) between the 2 groups (P>.05). The coefficient of repeatability of endothelial cell density was 131 cells/mm(2). The measured endothelial cell count per 1.0 mm(2) did not significantly change up to 1 year postoperatively in either group (both P>.05). No statistically significant difference was found between the 2 groups in any postoperative interval (P>.05). Photorefractive keratectomy for moderate myopia using a 213 nm wavelength solid-state laser or a conventional 193 nm wavelength excimer laser did not significantly affect corneal endothelial density during the 1-year postoperative period.

  2. A cost-minimization analysis of tissue-engineered constructs for corneal endothelial transplantation.

    PubMed

    Tan, Tien-En; Peh, Gary S L; George, Benjamin L; Cajucom-Uy, Howard Y; Dong, Di; Finkelstein, Eric A; Mehta, Jodhbir S

    2014-01-01

    Corneal endothelial transplantation or endothelial keratoplasty has become the preferred choice of transplantation for patients with corneal blindness due to endothelial dysfunction. Currently, there is a worldwide shortage of transplantable tissue, and demand is expected to increase further with aging populations. Tissue-engineered alternatives are being developed, and are likely to be available soon. However, the cost of these constructs may impair their widespread use. A cost-minimization analysis comparing tissue-engineered constructs to donor tissue procured from eye banks for endothelial keratoplasty was performed. Both initial investment costs and recurring costs were considered in the analysis to arrive at a final tissue cost per transplant. The clinical outcomes of endothelial keratoplasty with tissue-engineered constructs and with donor tissue procured from eye banks were assumed to be equivalent. One-way and probabilistic sensitivity analyses were performed to simulate various possible scenarios, and to determine the robustness of the results. A tissue engineering strategy was cheaper in both investment cost and recurring cost. Tissue-engineered constructs for endothelial keratoplasty could be produced at a cost of US$880 per transplant. In contrast, utilizing donor tissue procured from eye banks for endothelial keratoplasty required US$3,710 per transplant. Sensitivity analyses performed further support the results of this cost-minimization analysis across a wide range of possible scenarios. The use of tissue-engineered constructs for endothelial keratoplasty could potentially increase the supply of transplantable tissue and bring the costs of corneal endothelial transplantation down, making this intervention accessible to a larger group of patients. Tissue-engineering strategies for corneal epithelial constructs or other tissue types, such as pancreatic islet cells, should also be subject to similar pharmacoeconomic analyses.

  3. The Evolution of Corneal Transplantation.

    PubMed

    Röck, Tobias; Landenberger, Johanna; Bramkamp, Matthias; Bartz-Schmidt, Karl Ulrich; Röck, Daniel

    2017-12-15

    BACKGROUND The aim of this study was to investigate the evolution of surgical methods in and leading indications for corneal transplantation from 2005 to 2016. MATERIAL AND METHODS Data from the corneal graft waiting list and from all keratoplasties carried out between 2005 and 2016 at the University Eye Hospital Tübingen were retrospectively evaluated. RESULTS A total of 1259 keratoplasties were performed between 2005 and 2016 at the University Eye Hospital Tübingen. The most common surgical indications for corneal transplantation were Fuchs endothelial corneal dystrophy (45.5%) and keratoconus (14.2%). The mean rate of corneal transplantations almost doubled from 71 keratoplasties per year in the first 6-year period to 139 keratoplasties per year in the second 6-year period (P=0.005). The number of penetrating keratoplasties remained similar. The number of Descemet membrane endothelial keratoplasties (DMEK) increased significantly from 2008 to 2016 (P<0.0001). One DMEK procedure was performed in 2008 (representing 1.4% of all transplantations), while 75 DMEK procedures were performed in 2016 (representing 60.5% of all transplantations) (P<0.0001). DMEK became the favored surgical method for endothelial disorders, exceeding penetrating keratoplasty in 2013. CONCLUSIONS Our study shows evolutionary changes in preferred corneal transplantation techniques and leading indications for keratoplasty from 2005 to 2016. Since its introduction a decade ago, DMEK is currently the golden standard in the management of corneal endothelial dysfunction.

  4. Does endothelial cell density correlate with corneal diameter in a group of young adults?

    PubMed

    Giasson, Claude J; Gosselin, Lucie; Masella, Aviva; Forcier, Pierre

    2008-07-01

    In children, but not in the elderly, an association exists between corneal diameter and endothelial cell density (ECD). We tested whether such an association also held true in young adults. The eyes of 35 healthy subjects (mean age, 23.1 +/- 3.1 years) were photographed by using a video camera and a noncontact endothelial microscope. Both sets of images were analyzed with image software and the contour method to measure corneal diameter, ECD, and endothelial coefficients. Axial lengths, refractive errors, and corneal curvatures were measured by using an A-scan ultrasonic biometer and kerato-refractometer. Measurements, averaged for the right and left eyes, were analyzed depending on (1) use of contact lenses, (2) ametropia, and on whether (3) axial length or (4) corneal diameter was above or below group means. Differences were tested for statistical significance with independent t tests and association with the Pearson correlation coefficient. ECD, corneal diameter, and spherical equivalent refraction were 3022 +/- 262 cells/mm2, 12.0 +/- 0.5 mm, and -3.1 +/- 2.5 D, respectively. The only significant differences between wearers and nonwearers of contact lenses were the spherical refractive equivalent and axial length. There was no correlation between ECD and corneal diameter or axial length. As opposed to previously reported results in children, but as found in the elderly, there is no correlation between ECD and corneal diameter in young adults. Therefore, corneal size cannot be considered a determinant of ECD in young adults.

  5. Activation of Cytomegalovirus corneal endotheliitis following laser in situ keratomileusis.

    PubMed

    Tan, Tien-En; Cheung, Chui Ming Gemmy; Mehta, Jodhbir S

    2016-11-29

    A case of Cytomegalovirus (CMV) corneal endotheliitis following laser in-situ keratomileusis (LASIK) is presented. A 32-year-old man presented 3 weeks after uncomplicated myopic LASIK with unilateral LASIK flap oedema, interface fluid accumulation, keratic precipitates, anterior uveitis and raised intraocular pressure. Despite treatment with topical corticosteroids, he had 3 further recurrent episodes. Specular microscopy showed decreased endothelial cell density and aqueous humour. Polymerase chain reaction (PCR) testing was positive for CMV DNA. He was treated with topical ganciclovir and ketorolac, and the inflammation and oedema resolved. Repeat aqueous humour PCR testing was negative for CMV DNA, and he remained well at last follow-up (3 months after stopping all medications). CMV corneal endotheliitis can be reactivated after LASIK, and CMV DNA PCR of aqueous humour samples can help in definitive diagnosis. Early recognition and treatment of this condition is important to prevent permanent endothelial cell loss and corneal decompensation. 2016 BMJ Publishing Group Ltd.

  6. [Endothelial keratoplasty: Descemet stripping (DSEK) using TAN EndoGlide™ device: case series].

    PubMed

    Pazos, Henrique Santiago Baltar; Pazos, Paula Fernanda Morais Ramalho Baltar; Nogueira Filho, Pedro Antônio; Grisolia, Ana Beatriz Diniz; Silva, André Berger Emiliano; Gomes, José Álvaro Pereira

    2011-01-01

    To report the results of Descemet stripping endothelial keratoplasty (DSEK) using the TAN EndoGlideTM device to facilitate the insertion of the endothelial membrane. Prospective clinical study that included nine patients presenting corneal edema secondary to endothelial dysfunction. Best corrected visual acuity, refraction, central corneal thickness, endothelial cell density and complications were analyzed after a six-month follow-up. There was a significant improvement in the corneal edema and visual acuity in 7 patients (77.78%). The best corrected visual acuity ranged between 20/40 and 20/200. The average density of endothelial cells in six months varied between 1,305 cells/mm² and 2,346 cells/mm² with an average loss of 33.14% cells. Detachment of part of the graft was observed in one eye (11.11%) and primary failure of the endothelial transplantation occurred in 2 eyes (22.22%). The device TAN EndoGlideTM facilitates the introduction of the graft in Descemet stripping endothelial keratoplasty.

  7. Clinical significance of owl eye morphologic features by in vivo laser confocal microscopy in patients with cytomegalovirus corneal endotheliitis.

    PubMed

    Kobayashi, Akira; Yokogawa, Hideaki; Higashide, Tomomi; Nitta, Koji; Sugiyama, Kazuhisa

    2012-03-01

    To demonstrate the clinical significance of owl eye morphologic features observed by in vivo laser confocal microscopy in patients with cytomegalovirus (CMV) corneal endotheliitis. Observational case series. participants: Six eyes of 6 patients (6 men; mean age, 73.3 years) with cytomegalovirus corneal endotheliitis diagnosed by clinical manifestations together with polymerase chain reaction from aqueous humor samples. intervention: All patients were examined by slit-lamp biomicroscopy and in vivo laser confocal microscopy. main outcome measures: Clinical manifestations were summarized by reviewing medical records. Selected confocal images of corneal layers were evaluated qualitatively for shape and degree of light reflection of abnormal cells and deposits. All patients had long histories of anterior uveitis with intraocular pressure elevation, corneal edema with keratic precipitates, and decrease of endothelial cell densities. Coin-shaped lesions were observed by slit lamp only in 1 patient at the first visit and in 2 additional patients at subsequent follow-up. In all patients, confocal microscopy demonstrated reduced subepithelial nerves, subepithelial opacity, increased reflectivity of keratocytes, highly reflective dots, and needle-shaped bodies. Owl eye morphologic features were observed consistently in all patients at the initial visit, and highly reflective round bodies were detected in 5 patients; most notably, these confocal features were reversible after resolution of endotheliitis. Owl eye morphologic features and highly reflective round bodies observed by confocal microscopy may be useful as an adjunct for the noninvasive diagnosis of cytomegalovirus corneal endotheliitis. Reversibility of these features after resolution of endotheliitis may be useful for monitoring the therapeutic effects without multiple anterior chamber tap. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Accuracy of Corneal Thickness by Swept-Source Optical Coherence Tomography and Scheimpflug Camera in Virgin and Treated Fuchs Endothelial Dystrophy.

    PubMed

    Arnalich-Montiel, Francisco; Ortiz-Toquero, Sara; Auladell, Clara; Couceiro, Ana

    2018-06-01

    To assess intraobserver repeatability, intersession reproducibility, and agreement of swept-source Fourier-domain optical coherence tomography (SS-OCT) and the Scheimpflug camera in measuring corneal thickness in virgin and grafted eyes with Fuchs endothelial corneal dystrophy (FECD). Thirty-six control eyes, 35 FECD eyes, 30 FECD with corneal edema eyes, 25 Descemet stripping automated endothelial keratoplasty (DSAEK) eyes, and 29 Descemet membrane endothelial keratoplasty (DMEK) eyes were included. The apical center, pupillary center, and thinnest corneal thickness were determined in 3 consecutive images and repeated 2 weeks later. Repeatability and reproducibility coefficients, intraclass correlation coefficients, and 95% limits of agreement (LOA) between measurements were calculated. Agreement between devices was assessed using Bland-Altman analysis. Corneal thickness measurements were highly reproducible and repeatable with both systems. SS-OCT showed better repeatability in all corneal locations in the normal, FECD, FECD with edema, DSAEK, and DMEK groups (coefficient of variation ≤0.60%, ≤0.36%, ≤0.43%, ≤1.09%, and ≤0.48%, respectively) than the Scheimpflug (coefficient of variation ≤1.15%, ≤0.92%, ≤1.10%, ≤1.25%, and ≤1.14%, respectively). Between-session 95% LOA for SS-OCT was less than 3% for all groups except for the FECD with edema group, being almost double using the Scheimpflug camera. Differences between instruments were statistically significant in all groups and locations (P < 0.01) except in the DSAEK group (P ≤ 0.51); however, SS-OCT underestimated all measurements. SS-OCT provides better reproducible and repeatable measurements of corneal thickness than those obtained with the Scheimpflug camera in patients with FECD or an endothelial transplant. Variations between examinations higher than the 95% LOA observed in our study should raise awareness of changes in the endothelial function.

  9. Comparison of data from the rostock cornea module of the heidelberg retina tomograph, the oculus pentacam, and the endothelial cell microscope.

    PubMed

    Rieth, Sven; Engel, Felix; Bühner, Eva; Uhlmann, Susann; Wiedemann, Peter; Foja, Christian

    2010-03-01

    The aim of this study was to validate data arising from the Rostock Cornea Module (RCM) of the Heidelberg Retina Tomograph. Morphological parameters of the cornea were analyzed according to their dependency on patient's age. RCM measurements of 60 healthy eyes within 2 different age groups (group 1 <35 years, group 2 >50 years) were compared with the corneal thickness determined by the Oculus Pentacam and the endothelial cell density measured by the Tomey endothelial microscope, EM-2000. The mean corneal thickness measured with the Heidelberg Retina Tomograph/RCM was 517 +/- 31 microm and 542 +/- 30 microm with the Oculus Pentacam (correlation coefficient, R = 0.78). Group 1 showed a corneal thickness of 509 +/- 24 microm with the RCM and 531 +/- 27 microm with the Pentacam. In group 2, the corneal thickness was 525 +/- 34 microm and 553 +/- 29 microm, respectively. A significant increase in corneal thickness for older patients could be shown. The differences between the methods and the age groups were statistically significant (P < 0.0001). The average endothelial cell density measured with the RCM was 2779 +/- 472 cells per square millimeter. Between the age groups and the methods (RCM and endothelial microscope), no statistically significant differences could be found. Cell densities for the epithelial cell layers and keratocytes showed no significant correlation with age and sex of the patients. The RCM provides a reliable procedure for the evaluation of all corneal layers including morphological parameters. Endothelial cell densities either determined with the RCM or the EM-2000 are generally comparable to each other and showed no significant differences. It is suggested that lower corneal thickness measurements of the RCM can be caused by pressure during examination. An increased corneal thickness in the older group could be determined with the RCM and the Oculus Pentacam.

  10. Mapping owl's eye cells of patients with cytomegalovirus corneal endotheliitis using in vivo laser confocal microscopy.

    PubMed

    Yokogawa, Hideaki; Kobayashi, Akira; Sugiyama, Kazuhisa

    2013-01-01

    To produce a two-dimensional reconstruction map of owl's eye cells using in vivo laser confocal microscopy in patients with cytomegalovirus (CMV) corneal endotheliitis, and to demonstrate any association between owl's eye cells and coin-shaped lesions observed with slit-lamp biomicroscopy. Two patients (75- and 77-year-old men) with polymerase chain reaction-proven CMV corneal endotheliitis were evaluated in this study. Slit-lamp biomicroscopy and in vivo laser confocal microscopy were performed. Images of owl's eye cells in the endothelial cell layer were arranged and mapped into subconfluent montages. Montage images of owl's eye cells were then superimposed on a slit-lamp photo of the corresponding coin-shaped lesion. Degree of concordance between the confocal microscopic images and slit-lamp photos was evaluated. In both eyes, a two-dimensional reconstruction map of the owl's eye cells was created by computer software using acquired confocal images; the maps showed circular patterns. Superimposing montage images of owl's eye cells onto the photos of a coin-shaped lesion showed good concordance in the two eyes. This study suggests that there is an association between owl's eye cells observed by confocal microscopy and coin-shaped lesions observed by slit-lamp biomicroscopy in patients with CMV corneal endotheliitis. The use of in vivo laser confocal microscopy may provide clues as to the underlying causes of CMV corneal endotheliitis.

  11. Analysis of corneal endothelial cell density and morphology after laser in situ keratomileusis using two types of femtosecond lasers

    PubMed Central

    Tomita, Minoru; Waring, George O; Watabe, Miyuki

    2012-01-01

    Purpose To compare two different femtosecond lasers used for flap creation during laser-assisted in situ keratomileusis (LASIK) surgery in terms of their effects on the corneal endothelium. Methods We performed LASIK surgery on 254 eyes of 131 patients using IntraLase FS60 (Abbott Medical Optics, Inc, Irvine, CA; IntraLase group) and 254 eyes of 136 patients using Femto LDV (Ziemer Group AG, Port, Switzerland; LDV group) for corneal flap creation. The mean cell density, coefficient of variation, and hexagonality of the corneal endothelial cells were determined and the results were statistically compared. Results There were no statistically significant differences in the corneal morphology between pre and post LASIK results in each group, nor were there significant differences between the results of both groups at 3 months post LASIK. Conclusions Both IntraLase FS60 and Ziemer Femto LDV are able to create flaps without significant adverse effects on the corneal endothelial morphology through 3 months after LASIK surgery. PMID:23055680

  12. Smartphone-based imaging of the corneal endothelium at sub-cellular resolution

    NASA Astrophysics Data System (ADS)

    Toslak, Devrim; Thapa, Damber; Erol, Muhammet Kazim; Chen, Yanjun; Yao, Xincheng

    2017-07-01

    This aim of this study was to test the feasibility of smartphone-based specular microscopy of the corneal endothelium at a sub-cellular resolution. Quantitative examination of endothelial cells is essential for evaluating corneal disease such as determining a diagnosis, monitoring progression and assessing treatment. Smartphone-based technology promises a new opportunity to develop affordable devices to foster quantitative examination of endothelial cells in rural and underserved areas. In our study, we incorporated an iPhone 6 and a slit lamp to demonstrate the feasibility of smartphone-based microscopy of the corneal endothelium at a sub-cellular resolution. The sub-cellular resolution images allowed quantitative calculation of the endothelial cell density. Comparative measurements revealed a normal endothelial cell density of 2978 cells/mm2 in the healthy cornea, and a significantly reduced cell density of 1466 cells/mm2 in the diseased cornea with Fuchs' dystrophy. Our ultimate goal is to develop a smartphone-based telemedicine device for low-cost examination of the corneal endothelium, which can benefit patients in rural areas and underdeveloped countries to reduce health care disparities.

  13. Use of specular microscopy to determine corneal endothelial cell morphology and morphometry in enucleated cat eyes.

    PubMed

    Franzen, Angela A; Pigatto, João A T; Abib, Fernando C; Albuquerque, Luciane; Laus, José L

    2010-07-01

    The purpose of this study was to investigate the effect of age on endothelial morphology and morphometry in cats. The corneal endothelium was studied using a contact specular microscope. A total of 18 cats (Felis catus Linnaeus, 1758) were evaluated in this study. The subjects were divided into three groups of six cats each in function of age: G1 (1 to 3 months old), G2 (5 to 12 months old), and G3 (24 to 40 months old). The examination presented data as endothelial cell density (ECD), average cell area, corneal thickness, polymegathism, and pleomorphism. Results revealed ECD decrease in corneas of normal cats with age, as well as a corresponding increase in endothelial cell area and pleomorphism. The present work suggests that the endothelial parameters evaluated change with advancing age.

  14. RNA interference of GGTA1 physiological and immune functions in immortalized porcine aortic endothelial cells.

    PubMed

    Han, Wei; Zhou, Jingshi; Li, Xiao; Wang, Jianfeng; Li, Junjie; Zhang, Zhuochao; Yang, Zhaoxu; Wang, Desheng; Tao, Kaishan; Dou, Kefeng

    2013-11-01

    Pig organs are commonly used in xenotransplantation, and α-1,3-galactose has been shown to be the main cause of hyperacute rejection. The development of transgenic pigs that lack α-1,3-galactosyltransferase (GGTA1) has overcome this problem to a certain extent, but transgenic pigs are difficult to maintain, making their usefulness in basic research limited. For this reason, we propose to establish a cell model to study hyperacute rejection. Immortalized primary porcine aortic endothelial cells were transfected with a short hairpin RNA targeted to GGTA1. Cell proliferation, apoptosis, complement C3 activation, and the binding of human immunoglobulins and components of the complement system, including IgM, IgG, C3, and C5b-9, were examined. After RNA interference, GGTA1 was found to be reduced at both the transcript and protein level as assessed by quantitative polymerase chain reaction and flow cytometry, respectively. When cultured in the presence of human serum, the proliferation rate of the transfected cells was higher than that of untransfected cells, and the apoptosis rate was lower. Additionally, activation of C3 and the binding of human immunoglobulins IgM and IgG and complement component C3 and C5b-9 to the transfected cells were lower than in the immortalized group but higher than in untransfected cells. RNA interference of GGTA1 in cultured porcine endothelial cells reduces the reaction of immunoglobulin and complement system with the cells. Therefore, this in vitro cell model could be useful for further study of xenotransplantation. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Descemet Stripping Automated Endothelial Keratoplasty for Endothelial Dysfunction in Xeroderma Pigmentosum: A Clinicopathological Correlation and Review of Literature.

    PubMed

    Vira, Divya; Fernandes, Merle; Mittal, Ruchi

    2016-07-01

    Xeroderma pigmentosum (XP) mainly affects the ocular surface; however, endothelial damage may also occur. We would like to report changes in the endothelial-Descemet layer and review the literature on similar findings in patients with XP, including the role of Descemet stripping automated endothelial keratoplasty (DSAEK) in the management of a 21-year-old man who presented with nonresolving corneal edema in the right eye after excision biopsy for conjunctival intraepithelial neoplasia. His best-corrected visual acuity (BCVA) was 20/200 in the right eye and 20/20 in the left eye. On general examination, there was patchy hyperpigmentation of the exposed areas of skin suggestive of XP. On examination of the right eye, there was stromal edema involving the exposed half of cornea. The left eye appeared normal. Pachymetry readings were 860 and 600 μm in the right and left eye, respectively. Descemet stripping automated endothelial keratoplasty was performed for endothelial dysfunction and the stripped endothelium, and Descemet membrane (DM) was sent for histopathologic evaluation. Postoperatively, the donor lenticule was well apposed and the overlying stromal edema resolved. The patient achieved a BCVA of 20/30 in the right eye without progression of corneal scarring at 1-year follow-up. In the meanwhile, however, the left eye developed corneal edema. Histopathology revealed gross attenuation of endothelial cells with uniform thickness of the DM. Corneal endothelial dysfunction in XP is amenable to treatment with DSAEK.

  16. Refractive improvements and safety with topography-guided corneal crosslinking for keratoconus: 1-year results.

    PubMed

    Nordström, Maria; Schiller, Maria; Fredriksson, Anneli; Behndig, Anders

    2017-07-01

    To assess the refractive improvements and the corneal endothelial safety of an individualised topography-guided regimen for corneal crosslinking in progressive keratoconus. An open-label prospective randomised clinical trial was performed at the Department of Clinical Sciences, Ophthalmology, Umeå University Hospital, Umeå, Sweden. Thirty-seven patients (50 eyes) with progressive keratoconus planned for corneal crosslinking were included. The patients were randomised to topography-guided crosslinking (photorefractive intrastromal crosslinking (PiXL); n=25) or uniform 9 mm crosslinking (corneal collagen crosslinking (CXL); n=25). Visual acuity, refraction, keratometry (K1, K2 and K max ) and corneal endothelial morphometry were assessed preoperatively and at 1, 3, 6 and 12 months postoperatively. The PiXL treatment involved an asymmetrical treatment zone centred on the area of maximum corneal steepness with treatment energies ranging from 7.2 to 15.0 J/cm 2 ; the CXL treatment was a uniform 9 mm 5.4 J/cm 2 pulsed crosslinking. The main outcome measures were changes in refractive errors and corneal endothelial cell density. The spherical refractive errors decreased (p<0.05) and the visual acuity improved (p<0.01) at 3, 6 and 12 months after PiXL, but not after CXL. The between-groups differences, however, were not significant. K2 and K max decreased at 3, 6 and 12 months after PiXL (p<0.01), but not after CXL (p<0.01 when comparing the two treatments). No corneal endothelial cell loss was seen after either treatment. Individualised topography-based crosslinking treatment centred on the ectatic cone has the potential to improve the corneal shape in keratoconus with decreased spherical refractive errors and improved visual acuity, without damage to the corneal endothelium. NCT02514200, Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Conditionally Immortal Slc4a11-/- Mouse Corneal Endothelial Cell Line Recapitulates Disrupted Glutaminolysis Seen in Slc4a11-/- Mouse Model.

    PubMed

    Zhang, Wenlin; Ogando, Diego G; Kim, Edward T; Choi, Moon-Jung; Li, Hongde; Tenessen, Jason M; Bonanno, Joseph A

    2017-07-01

    To establish conditionally immortal mouse corneal endothelial cell lines with genetically matched Slc4a11+/+ and Slc4a11-/- mice as a model for investigating pathology and therapies for SLC4A11 associated congenital hereditary endothelial dystrophy (CHED) and Fuchs' endothelial corneal dystrophy. We intercrossed H-2Kb-tsA58 mice (Immortomouse) expressing an IFN-γ dependent and temperature-sensitive mutant of the SV40 large T antigen (tsTAg) with Slc4a11+/+ and Slc4a11-/- C57BL/6 mice. The growth characteristics of the cell lines was assessed by doubling time. Ion transport activities (Na+/H+ exchange, bicarbonate, lactate, and Slc4a11 ammonia transport) were analyzed by intracellular pH measurement. The metabolic status of the cell lines was assessed by analyzing TCA cycle intermediates via gas chromatography mass spectrometry (GC-MS). The immortalized Slc4a11+/+ and Slc4a11-/- mouse corneal endothelial cells (MCECs) remained proliferative through passage 49 and maintained similar active ion transport activity. As expected, proliferation was temperature sensitive and IFN-γ dependent. Slc4a11-/- MCECs exhibited decreased proliferative capacity, reduced NH3:H+ transport, altered expression of glutaminolysis enzymes similar to the Slc4a11-/- mouse, and reduced proportion of TCA cycle intermediates derived from glutamine with compensatory increases in glucose flux compared with Slc4a11+/+ MCECs. This is the first report of the immortalization of MCECs. Ion transport of the immortalized endothelial cells remains active, except for NH3:H+ transporter activity in Slc4a11-/- MCECs. Furthermore, Slc4a11-/- MCECs recapitulate the glutaminolysis defects observed in Slc4a11-/- mouse corneal endothelium, providing an excellent tool to study the pathogenesis of SLC4A11 mutations associated with corneal endothelial dystrophies and to screen potential therapeutic agents.

  18. Corneal Endothelial Alterations in Chronic Renal Failure.

    PubMed

    Sati, Alok; Jha, Ashok; Moulick, P S; Shankar, Sandeep; Gupta, Sandeep; Khan, M A; Dogra, Manu; Sangwan, Virender S

    2016-10-01

    To evaluate the corneal endothelial changes in patients with chronic renal failure. A total of 128 corneas of 128 subjects were studied, and 3 groups were formed. The first, the dialyzed group, composed of 32 corneas of 32 patients; the second, the nondialyzed group, composed of 34 corneas of 34 patients; and the third, the age-matched control group, composed of 64 corneas of 64 healthy subjects were examined by a specular microscope and the endothelial parameters were compared. The dialyzed group (enhanced level of toxins in the blood) was further analyzed to assess the influence of blood urea, serum creatinine, serum calcium, and serum phosphorus including the duration of dialysis on corneal endothelium. On comparing the 3 groups using analysis of variance and posthoc tests, a significant difference was found in the central corneal thickness (CCT) and endothelial cell density (CD) between the control (CCT: 506 ± 29 μm, CD: 2760 ± 304 cells/mm) and dialyzed groups (CCT: 549 ± 30 μm, CD: 2337 ± 324 cells/mm) [P < 0.001 (CCT); P < 0.001 (CD)]; control and nondialyzed groups (CCT: 524 ± 27 μm, CD: 2574 ± 260 cells/mm) [P = 0.023 (CCT); P = 0.016 (CD)]; and dialyzed and nondialyzed groups [P = 0.002 (CCT); P = 0.007 (CD)]. Using the linear generalized model, a significant correlation was found between the endothelial parameters and blood urea only [P = 0.006 (CCT), 0.002 (coefficient of variation), 0.022 (CD), and 0.026 (percentage of hexagonality)], although the correlation was poorly positive for CCT but poorly negative for the remaining endothelial parameters. Corneal endothelial alteration is present in patients with chronic renal failure, more marked in patients undergoing hemodialysis and with raised blood urea level.

  19. Progress in corneal wound healing

    PubMed Central

    Ljubimov, Alexander V.; Saghizadeh, Mehrnoosh

    2015-01-01

    Corneal wound healing is a complex process involving cell death, migration, proliferation, differentiation, and extracellular matrix remodeling. Many similarities are observed in the healing processes of corneal epithelial, stromal and endothelial cells, as well as cell-specific differences. Corneal epithelial healing largely depends on limbal stem cells and remodeling of the basement membrane. During stromal healing, keratocytes get transformed to motile and contractile myofibroblasts largely due to activation of transforming growth factor-β system. Endothelial cells heal mostly by migration and spreading, with cell proliferation playing a secondary role. In the last decade, many aspects of wound healing process in different parts of the cornea have been elucidated, and some new therapeutic approaches have emerged. The concept of limbal stem cells received rigorous experimental corroboration, with new markers uncovered and new treatment options including gene and microRNA therapy tested in experimental systems. Transplantation of limbal stem cell-enriched cultures for efficient re-epithelialization in stem cell deficiency and corneal injuries has become reality in clinical setting. Mediators and course of events during stromal healing have been detailed, and new treatment regimens including gene (decorin) and stem cell therapy for excessive healing have been designed. This is a very important advance given the popularity of various refractive surgeries entailing stromal wound healing. Successful surgical ways of replacing the diseased endothelium have been clinically tested, and new approaches to accelerate endothelial healing and suppress endothelial-mesenchymal transformation have been proposed including Rho kinase (ROCK) inhibitor eye drops and gene therapy to activate TGF-β inhibitor SMAD7. Promising new technologies with potential for corneal wound healing manipulation including microRNA, induced pluripotent stem cells to generate corneal epithelium, and nanocarriers for corneal drug delivery are discussed. Attention is also paid to problems in wound healing understanding and treatment, such as lack of specific epithelial stem cell markers, reliable identification of stem cells, efficient prevention of haze and stromal scar formation, lack of data on wound regulating microRNAs in keratocytes and endothelial cells, as well as virtual lack of targeted systems for drug and gene delivery to select corneal cells. PMID:26197361

  20. Progress in corneal wound healing.

    PubMed

    Ljubimov, Alexander V; Saghizadeh, Mehrnoosh

    2015-11-01

    Corneal wound healing is a complex process involving cell death, migration, proliferation, differentiation, and extracellular matrix remodeling. Many similarities are observed in the healing processes of corneal epithelial, stromal and endothelial cells, as well as cell-specific differences. Corneal epithelial healing largely depends on limbal stem cells and remodeling of the basement membrane. During stromal healing, keratocytes get transformed to motile and contractile myofibroblasts largely due to activation of transforming growth factor-β (TGF-β) system. Endothelial cells heal mostly by migration and spreading, with cell proliferation playing a secondary role. In the last decade, many aspects of wound healing process in different parts of the cornea have been elucidated, and some new therapeutic approaches have emerged. The concept of limbal stem cells received rigorous experimental corroboration, with new markers uncovered and new treatment options including gene and microRNA therapy tested in experimental systems. Transplantation of limbal stem cell-enriched cultures for efficient re-epithelialization in stem cell deficiency and corneal injuries has become reality in clinical setting. Mediators and course of events during stromal healing have been detailed, and new treatment regimens including gene (decorin) and stem cell therapy for excessive healing have been designed. This is a very important advance given the popularity of various refractive surgeries entailing stromal wound healing. Successful surgical ways of replacing the diseased endothelium have been clinically tested, and new approaches to accelerate endothelial healing and suppress endothelial-mesenchymal transformation have been proposed including Rho kinase (ROCK) inhibitor eye drops and gene therapy to activate TGF-β inhibitor SMAD7. Promising new technologies with potential for corneal wound healing manipulation including microRNA, induced pluripotent stem cells to generate corneal epithelium, and nanocarriers for corneal drug delivery are discussed. Attention is also paid to problems in wound healing understanding and treatment, such as lack of specific epithelial stem cell markers, reliable identification of stem cells, efficient prevention of haze and stromal scar formation, lack of data on wound regulating microRNAs in keratocytes and endothelial cells, as well as virtual lack of targeted systems for drug and gene delivery to select corneal cells. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Apatinib-loaded nanoparticles suppress vascular endothelial growth factor-induced angiogenesis and experimental corneal neovascularization.

    PubMed

    Lee, Jung Eun; Kim, Koung Li; Kim, Danbi; Yeo, Yeongju; Han, Hyounkoo; Kim, Myung Goo; Kim, Sun Hwa; Kim, Hyuncheol; Jeong, Ji Hoon; Suh, Wonhee

    2017-01-01

    Pathological angiogenesis is one of the major symptoms of severe ocular diseases, including corneal neovascularization. The blockade of vascular endothelial growth factor (VEGF) action has been recognized as an efficient strategy for treating corneal neovascularization. In this study, we aimed to investigate whether nanoparticle-based delivery of apatinib, a novel and selective inhibitor of VEGF receptor 2, inhibits VEGF-mediated angiogenesis and suppresses experimental corneal neovascularization. Water-insoluble apatinib was encapsulated in nanoparticles composed of human serum albumin (HSA)-conjugated polyethylene glycol (PEG). In vitro angiogenesis assays showed that apatinib-loaded HSA-PEG (Apa-HSA-PEG) nanoparticles potently inhibited VEGF-induced tube formation, scratch wounding migration, and proliferation of human endothelial cells. In a rat model of alkali burn injury-induced corneal neovascularization, a subconjunctival injection of Apa-HSA-PEG nanoparticles induced a significant decrease in neovascularization compared to that observed with an injection of free apatinib solution or phosphate-buffered saline. An in vivo distribution study using HSA-PEG nanoparticles loaded with fluorescent hydrophobic model drugs revealed the presence of a substantial number of nanoparticles in the corneal stroma within 24 h after injection. These in vitro and in vivo results demonstrate that apatinib-loaded nanoparticles may be promising for the prevention and treatment of corneal neovascularization-related ocular disorders.

  2. Apatinib-loaded nanoparticles suppress vascular endothelial growth factor-induced angiogenesis and experimental corneal neovascularization

    PubMed Central

    Lee, Jung Eun; Kim, Koung Li; Kim, Danbi; Yeo, Yeongju; Han, Hyounkoo; Kim, Myung Goo; Kim, Sun Hwa; Kim, Hyuncheol; Jeong, Ji Hoon; Suh, Wonhee

    2017-01-01

    Pathological angiogenesis is one of the major symptoms of severe ocular diseases, including corneal neovascularization. The blockade of vascular endothelial growth factor (VEGF) action has been recognized as an efficient strategy for treating corneal neovascularization. In this study, we aimed to investigate whether nanoparticle-based delivery of apatinib, a novel and selective inhibitor of VEGF receptor 2, inhibits VEGF-mediated angiogenesis and suppresses experimental corneal neovascularization. Water-insoluble apatinib was encapsulated in nanoparticles composed of human serum albumin (HSA)-conjugated polyethylene glycol (PEG). In vitro angiogenesis assays showed that apatinib-loaded HSA-PEG (Apa-HSA-PEG) nanoparticles potently inhibited VEGF-induced tube formation, scratch wounding migration, and proliferation of human endothelial cells. In a rat model of alkali burn injury-induced corneal neovascularization, a subconjunctival injection of Apa-HSA-PEG nanoparticles induced a significant decrease in neovascularization compared to that observed with an injection of free apatinib solution or phosphate-buffered saline. An in vivo distribution study using HSA-PEG nanoparticles loaded with fluorescent hydrophobic model drugs revealed the presence of a substantial number of nanoparticles in the corneal stroma within 24 h after injection. These in vitro and in vivo results demonstrate that apatinib-loaded nanoparticles may be promising for the prevention and treatment of corneal neovascularization-related ocular disorders. PMID:28740387

  3. Cross-Linking as an Adjuvant Treatment for Tectonic Corneal Lamellar Graft Preparation

    PubMed Central

    Kymionis, George D.; Plaka, Argyro D.; Diakonis, Vasilios F.; Grentzelos, Michael A.; Kontadakis, Georgios A.; Mersinoglou, Andreana C.; Detorakis, Efstathios T.; Topouzis, Fotis

    2013-01-01

    Purpose: To describe a new surgical approach for the tectonic reconstruction of the anterior ocular segment and the management of scleral and conjuctival melting. Methods: Case series of patients demonstrating anterior segment anomalies, such as scleral and conjunctival melting. The anterior stromal part of a pre-cut corneal graft for Descemet’s stripping automated endothelial keratoplasty (DSAEK) was cross-linked with riboflavin and ultraviolet A irradiation and was used to cover scleral (scleral melting in a patient with necrotizing scleritis, one case) and conjuctival (dehiscence of the conjunctiva in patients with anti-glaucomatous valve exposure, two cases) areas. The endothelial part of all corneal grafts was used for DSAEK in patients with need of corneal endothelial transplantation. Results: Repair of scleral and conjuctival melting was successful in all cases. No intra- or post- operative complications occured. Visual acuity of all patients remained stable during the follow up period. One year postoperatively the corneal graft remained in place and no signs of inflammation were evident, while all grafts were epithelialized. Conclusions: The use of cross-linked corneal graft for the tectonic reconstruction of the anterior ocular segment represents an adequate surgical approach for the management of scleral and conjuctival melting; while, at the same time it offers the advantage of using one corneal graft for two recipients. PMID:24278090

  4. Identification of Therapeutic Targets of Inflammatory Monocyte Recruitment to Modulate the Allogeneic Injury to Donor Cornea.

    PubMed

    Lapp, Thabo; Zaher, Sarah S; Haas, Carolin T; Becker, David L; Thrasivoulou, Chris; Chain, Benjamin M; Larkin, Daniel F P; Noursadeghi, Mahdad

    2015-11-01

    We sought to test the hypothesis that monocytes contribute to the immunopathogenesis of corneal allograft rejection and identify therapeutic targets to inhibit monocyte recruitment. Monocytes and proinflammatory mediators within anterior chamber samples during corneal graft rejection were quantified by flow cytometry and multiplex protein assays. Lipopolysaccharide or IFN-γ stimulation of monocyte-derived macrophages (MDMs) was used to generate inflammatory conditioned media (CoM). Corneal endothelial viability was tested by nuclear counting, connexin 43, and propidium iodide staining. Chemokine and chemokine receptor expression in monocytes and MDMs was assessed in microarray transcriptomic data. The role of chemokine pathways in monocyte migration across microvascular endothelium was tested in vitro by chemokine depletion or chemokine receptor inhibitors. Inflammatory monocytes were significantly enriched in anterior chamber samples within 1 week of the onset of symptoms of corneal graft rejection. The MDM inflammatory CoM was cytopathic to transformed human corneal endothelia. This effect was also evident in endothelium of excised human cornea and increased in the presence of monocytes. Gene expression microarrays identified monocyte chemokine receptors and cognate chemokines in MDM inflammatory responses, which were also enriched in anterior chamber samples. Depletion of selected chemokines in MDM inflammatory CoM had no effect on monocyte transmigration across an endothelial blood-eye barrier, but selective chemokine receptor inhibition reduced monocyte recruitment significantly. We propose a role for inflammatory monocytes in endothelial cytotoxicity in corneal graft rejection. Therefore, targeting monocyte recruitment offers a putative novel strategy to reduce donor endothelial cell injury in survival of human corneal allografts.

  5. Corneal Astigmatism Stability in Descemet Membrane Endothelial Keratoplasty for Fuchs Corneal Dystrophy.

    PubMed

    Yokogawa, Hideaki; Sanchez, P James; Mayko, Zachary M; Straiko, Michael D; Terry, Mark A

    2016-07-01

    To calculate the magnitude and angle of the shift in corneal astigmatism associated with Descemet membrane endothelial keratoplasty (DMEK) surgery to determine the feasibility of concurrent astigmatism correction at the time of DMEK triple procedures. Retrospective study. Forty-seven eyes that previously underwent the DMEK procedure for Fuchs endothelial corneal dystrophy and that had more than 1.0 diopter (D) of front corneal astigmatism preoperatively were identified. All DMEK surgeries used a clear corneal temporal incision of 3.2 mm. Surgically induced astigmatism (SIA) was evaluated 6 months postsurgery with vector analysis using Scheimpflug image reading. We did not find a difference between pre- and postoperative magnitude of front astigmatism (P = 0.88; paired t test). The magnitude of the SIA front surface was 0.77 ± 0.63 D (range, 0.10-3.14 D). The centroid vector of the SIA front surface was 0.14 at 89.3°. A hyperopic corneal power shift was noted in both the front surface by 0.26 ± 0.74 D (range, 0.45-3.05 D) (P = 0.018; paired t test) and back surface by 0.56 ± 0.55 D (range, 0.25-2.40 D) (P < 0.01; paired t test). DMEK surgery induces minimal amounts of corneal astigmatism that is a with-the-rule shift associated with a temporal clear corneal incision. The stability of these data from preop to postop supports the plausibility of incorporating astigmatism correction with the cautious use of toric intraocular lenses for patients with Fuchs corneal dystrophy and cataract.

  6. Serial corneal endothelial cell loss with lathe-cut and injection-molded posterior chamber intraocular lenses.

    PubMed

    Kraff, M C; Sanders, D R; Lieberman, H L

    1983-01-01

    We compared endothelial cell loss of patients implanted with lathe-cut posterior chamber lenses and those implanted with injection-molded lenses over a three-year postoperative period. Results were based on more than 2,500 measurements of corneal endothelial density. Although the technique of cataract extraction (anterior chamber phacoemulsification, posterior chamber phacoemulsification, or planned extracapsular extraction) significantly affected cell loss (P less than .01), the type of implant (lathe-cut or injection-molded) did not. Significant continuing endothelial cell loss did not occur during the first three postoperative years with injection-molded lenses. There was, however, a statistically significant 7% to 15% additional cell loss after surgery over the first two to three postoperative years with lathe-cut implants. There have been no cases of corneal endothelial decompensation developing after implantation of injection-molded or lathe-cut lenses. Because a standard field clinical specular microscope was used in this study, cell counting errors cannot be ruled out as a cause of these findings.

  7. Safety of intracameral injection of gatifloxacin, levofloxacin on corneal endothelial structure and viability.

    PubMed

    Choi, Jin A; Chung, Sung Kun

    2009-10-01

    To investigate the safety of intracameral injection of gatifloxacin, levofloxacin in a rabbit model as prophylaxis against endophthalmitis. Twenty-four eyes of New Zealand white rabbits were randomly divided into 3 treatment groups: levofloxacin, gatifloxacin, and balanced salt solution (BSS) control groups. After 100 microL of each was injected into the anterior chamber, endothelial toxicity was evaluated by measuring the central corneal thicknesses and the clinical toxicity scores using a slit-lamp at post-procedure days 3 and 7. The percent of dead cells was determined by vital staining with alizarin red and trypan blue at 7 days after injection. Finally, in each group, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were performed for the evaluation of structural integrity. The toxicity scores were increased at post-procedure days 3 and 7, but the difference among the groups was not statistically significant (P = 0.661, 0.216, respectively). With regard to baseline corneal thickness, only the levofloxacin group exhibited a significant increase from baseline (P = 0.028), whereas the other treatment groups showed no difference from baseline (P = 0.128 in gatifloxacin, 0.161 in BSS group). The mean corneal endothelial damage was 0.81 +/- 0.31% in the levofloxacin group, 0.56 +/- 0.47% in the gatifloxacin group, and 0.53 +/- 0.52% in the BSS group, with no statistically significant difference noted among the groups (P = 0.582). SEM revealed a well-preserved hexagonal endothelial cell mosaic and normal microvilli on the endothelial cell surface in the gatifloxacin and control groups. However, the levofloxacin group showed slightly disintegrated cellular borders. TEM revealed that each group maintained normal intracellular organization, whereas the levofloxacin group exhibited slightly flat cell configuration with irregular folds on the apical cell surface. Intracameral injection of gatifloxacin and levofloxacin was nontoxic in terms of clinical toxicity score, corneal thickness, and viability. However, there were changes on electron microscopy in the levofloxacin group, which may indicate microstructural damage to corneal endothelial cells.

  8. Conditionally Immortal Slc4a11−/− Mouse Corneal Endothelial Cell Line Recapitulates Disrupted Glutaminolysis Seen in Slc4a11−/− Mouse Model

    PubMed Central

    Zhang, Wenlin; Ogando, Diego G.; Kim, Edward T.; Choi, Moon-Jung; Li, Hongde; Tenessen, Jason M.; Bonanno, Joseph A.

    2017-01-01

    Purpose To establish conditionally immortal mouse corneal endothelial cell lines with genetically matched Slc4a11+/+ and Slc4a11−/− mice as a model for investigating pathology and therapies for SLC4A11 associated congenital hereditary endothelial dystrophy (CHED) and Fuchs' endothelial corneal dystrophy. Methods We intercrossed H-2Kb-tsA58 mice (Immortomouse) expressing an IFN-γ dependent and temperature-sensitive mutant of the SV40 large T antigen (tsTAg) with Slc4a11+/+ and Slc4a11−/− C57BL/6 mice. The growth characteristics of the cell lines was assessed by doubling time. Ion transport activities (Na+/H+ exchange, bicarbonate, lactate, and Slc4a11 ammonia transport) were analyzed by intracellular pH measurement. The metabolic status of the cell lines was assessed by analyzing TCA cycle intermediates via gas chromatography mass spectrometry (GC-MS). Results The immortalized Slc4a11+/+ and Slc4a11−/− mouse corneal endothelial cells (MCECs) remained proliferative through passage 49 and maintained similar active ion transport activity. As expected, proliferation was temperature sensitive and IFN-γ dependent. Slc4a11−/− MCECs exhibited decreased proliferative capacity, reduced NH3:H+ transport, altered expression of glutaminolysis enzymes similar to the Slc4a11−/− mouse, and reduced proportion of TCA cycle intermediates derived from glutamine with compensatory increases in glucose flux compared with Slc4a11+/+ MCECs. Conclusions This is the first report of the immortalization of MCECs. Ion transport of the immortalized endothelial cells remains active, except for NH3:H+ transporter activity in Slc4a11−/− MCECs. Furthermore, Slc4a11−/− MCECs recapitulate the glutaminolysis defects observed in Slc4a11−/− mouse corneal endothelium, providing an excellent tool to study the pathogenesis of SLC4A11 mutations associated with corneal endothelial dystrophies and to screen potential therapeutic agents. PMID:28738416

  9. Correlation of corneal thickness, endothelial cell density and anterior chamber depth with ocular surface temperature in normal subjects.

    PubMed

    Pattmöller, Johanna; Wang, Jiong; Zemova, Elena; Seitz, Berthold; Eppig, Timo; Langenbucher, Achim; Szentmáry, Nóra

    2015-09-01

    To analyze corneal surface temperature profile in a young and healthy study population and to determine the impact of corneal thickness (CT), anterior chamber depth (ACD), and endothelial cell density (ECD) on surface temperature. In this prospective, single-center study 61 healthy right eyes of 61 subjects without tear film pathologies (mean age 24.9 ± 6.7 years) were recruited. Ocular surface temperature (OST) was measured with the Ocular Surface Thermographer TG-1000. From Pentacam HR CT and ACD, and from specular microscopy ECD and central corneal thickness (CCT) were acquired. From the raw measurement data (OST, CT and ACD) we extracted a) local OST the corneal center and 3mm away from the center at the 3, 6, and 9 o'clock positions, and b) Zernike parameters Z1, Z2 and Z3 to evaluate the general temperature profile within a 6mm circular area around the center. Overall, there was no correlation between OST and CT, ACD or ECD. Local OST did not correlate with CT at any measurement position. On average local OST was highest at measurement positions where CT was lowest, but without reaching statistical significance. Baseline OST was highest at thin corneal regions and temperature decay over time was smallest in those regions. Z1, Z2 and Z3 correlated well with CT. In healthy subjects corneal thickness, endothelial cell density and anterior chamber depth have no effect on corneal surface temperature. The general temperature profile seems to be influenced by the corneal thickness profile effecting a higher temperature and lower decay at thinner corneal regions. Copyright © 2014. Published by Elsevier GmbH.

  10. Cataract surgery in eyes with low corneal endothelial cell density.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Manabe, Shin-ichi; Hirata, Akira

    2011-08-01

    To compare corneal endothelial damage after cataract surgery in eyes with low endothelial cell density (ECD) and eyes with normal ECD. Hayashi Eye Hospital, Fukuoka, Japan. Case-control study. Cataract surgery was performed in eyes with a low ECD (500 to 1000 cells/mm(2)) (low-density group) and control eyes with a normal ECD. The ECD and central corneal thickness (CCT) were measured preoperatively and 1 and 3 months postoperatively, and the percentage cell loss and increase in CCT were compared. The low-density group and control group each comprised 50 eyes. In the low-density group, 39 eyes had nonprogressive endothelial pathology and 11 had Fuchs dystrophy. The mean ECD was significantly less and the CCT significantly greater in the low-density group than in the control group throughout the follow-up (P ≤.0066). However, no significant difference in the percentage of cell loss was found between groups at 1 or 3 months (5.1%, low-density group; 4.2%, control group) (P ≥.1477). The percentage increase in CCT was significantly greater in the low-density group than in the control group at 1 month (P<.0001), although there was no significant difference at 3 months (0.4% and -0.4%, respectively) (P=.2172). Corneal endothelial damage after cataract surgery in eyes with low ECD was slight and comparable to that in healthy eyes, which suggests that cataract surgery alone (without corneal transplantation) should be performed first. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Real-time assessment of corneal endothelial cell damage following graft preparation and donor insertion for DMEK

    PubMed Central

    Bhogal, Maninder; Lwin, Chan N.; Seah, Xin-Yi; Murugan, Elavazhagan; Adnan, Khadijah; Lin, Shu-Jun; Mehta, Jodhbir S.

    2017-01-01

    Purpose To establish a method for assessing graft viability, in-vivo, following corneal transplantation. Methods Optimization of calcein AM fluorescence and toxicity assessment was performed in cultured human corneal endothelial cells and ex-vivo corneal tissue. Descemet membrane endothelial keratoplasty grafts were incubated with calcein AM and imaged pre and post preparation, and in-situ after insertion and unfolding in a pig eye model. Global, macroscopic images of the entire graft and individual cell resolution could be attained by altering the magnification of a clinical confocal scanning laser microscope. Patterns of cell loss observed in situ were compared to those seen using standard ex-vivo techniques. Results Calcein AM showed a positive dose-fluorescence relationship. A dose of 2.67μmol was sufficient to allow clear discrimination between viable and non-viable areas (sensitivity of 96.6% with a specificity of 96.1%) and was not toxic to cultured endothelial cells or ex-vivo corneal tissue. Patterns of cell loss seen in-situ closely matched those seen on ex-vivo assessment with fluorescence viability imaging, trypan blue/alizarin red staining or scanning electron microscopy. Iatrogenic graft damage from preparation and insertion varied between 7–35% and incarceration of the graft tissue within surgical wounds was identified as a significant cause of endothelial damage. Conclusions In-situ graft viability assessment using clinical imaging devices provides comparable information to ex-vivo methods. This method shows high sensitivity and specificity, is non-toxic and can be used to evaluate immediate cell viability in new grafting techniques in-vivo. PMID:28977017

  12. Mitochondrial and Morphologic Alterations in Native Human Corneal Endothelial Cells Associated With Diabetes Mellitus.

    PubMed

    Aldrich, Benjamin T; Schlötzer-Schrehardt, Ursula; Skeie, Jessica M; Burckart, Kimberlee A; Schmidt, Gregory A; Reed, Cynthia R; Zimmerman, M Bridget; Kruse, Friedrich E; Greiner, Mark A

    2017-04-01

    To characterize changes in the energy-producing metabolic activity and morphologic ultrastructure of corneal endothelial cells associated with diabetes mellitus. Transplant suitable corneoscleral tissue was obtained from donors aged 50 to 75 years. We assayed 3-mm punches of endothelium-Descemet membrane for mitochondrial respiration and glycolysis activity using extracellular flux analysis of oxygen and pH, respectively. Transmission electron microscopy was used to assess qualitative and quantitative ultrastructural changes in corneal endothelial cells and associated Descemet membrane. For purposes of analysis, samples were divided into four groups based on a medical history of diabetes regardless of type: (1) nondiabetic, (2) noninsulin-dependent diabetic, (3) insulin-dependent diabetic, and (4) insulin-dependent diabetic with specified complications due to diabetes (advanced diabetic). In total, 229 corneas from 159 donors were analyzed. Insulin-dependent diabetic samples with complications due to diabetes displayed the lowest spare respiratory values compared to all other groups (P ≤ 0.002). The remaining mitochondrial respiration and glycolysis metrics did not differ significantly among groups. Compared to nondiabetic controls, the endothelium from advanced diabetic samples had alterations in mitochondrial morphology, pronounced Golgi bodies associated with abundant vesicles, accumulation of lysosomal bodies/autophagosomes, and focal production of abnormal long-spacing collagen. Extracellular flux analysis suggests that corneal endothelial cells of donors with advanced diabetes have impaired mitochondrial function. Metabolic findings are supported by observed differences in mitochondrial morphology of advanced diabetic samples but not controls. Additional studies are needed to determine the precise mechanism(s) by which mitochondria become impaired in diabetic corneal endothelial cells.

  13. Assessing microstructures of the cornea with Gabor-domain optical coherence microscopy: pathway for corneal physiology and diseases.

    PubMed

    Tankam, Patrice; He, Zhiguo; Chu, Ying-Ju; Won, Jungeun; Canavesi, Cristina; Lepine, Thierry; Hindman, Holly B; Topham, David J; Gain, Philippe; Thuret, Gilles; Rolland, Jannick P

    2015-03-15

    Gabor-domain optical coherence microscopy (GD-OCM) was applied ex vivo in the investigation of corneal cells and their surrounding microstructures with particular attention to the corneal endothelium. Experiments using fresh pig eyeballs, excised human corneal buttons from patients with Fuchs' endothelial dystrophy (FED), and healthy donor corneas were conducted. Results show in a large field of view (1  mm×1  mm) high definition images of the different cell types and their surrounding microstructures through the full corneal thickness at both the central and peripheral locations of porcine corneas. Particularly, an image of the endothelial cells lining the bottom of the cornea is highlighted. As compared to healthy human corneas, the corneas of individuals with FED show characteristic microstructural alterations of the Descemet's membrane and increased size and number of keratocytes. The GD-OCM-based imaging system developed may constitute a novel tool for corneal imaging and disease diagnosis. Also, importantly, it may provide insights into the mechanism of corneal physiology and pathology, particularly in diseases of the corneal endothelium.

  14. Effects of humidified and dry air on corneal endothelial cells during vitreal fluid-air exchange.

    PubMed

    Cekiç, Osman; Ohji, Masahito; Hayashi, Atsushi; Fang, Xiao Y; Kusaka, Shunji; Tano, Yasuo

    2002-07-01

    To report the immediate anatomic and functional alterations in corneal endothelial cells following use of humidified air and dry air during vitreal fluid-air exchange in rabbits. Experimental study. Rabbits undergoing pars plana vitrectomy and lensectomy were perfused with either dry or humidified air during fluid-air exchange for designated durations. Three different experiments were performed. First, control and experimental corneas were examined by scanning electron microscopy (SEM). Second, corneas were stained with Phalloidin-FITC and examined by fluorescein microscopy. Finally, third, transendothelial permeability for carboxyfluorescein was determined using a diffusion chamber. While different from the corneal endothelial cells, those cells exposed to humidified air were less stressed than cells exposed to dry air by SEM. Actin cytoskeleton was found highly disorganized with dry air exposure. Humidified air maintained the normal actin cytoskeleton throughout the 20 minutes of fluid-air exchange. Paracellular carboxyfluorescein leakage was significantly higher in dry air insufflated eyes compared with that of the humidified air after 5, 10, and 20 minutes of fluid-air exchange (P =.002, P =.004, and P =.002, respectively). Dry air stress during fluid-air exchange causes significant immediate alterations in monolayer appearance, actin cytoskeleton, and barrier function of corneal endothelium in aphakic rabbit eyes. Use of humidified air largely prevents the alterations in monolayer appearance, actin cytoskeleton, and barrier function of corneal endothelial cells.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu Hui; Wu Jihong; Li Huiming

    The interaction of vascular endothelial growth factor (VEGF) and its receptors (Flt-1, Flk-1/KDR) is correlated with neovascularization in the eyes. Therefore, blocking the binding of VEGF and the corresponding receptor has become critical for inhibiting corneal neovascularization. In this study, we have expressed the cDNA for sFlk-1 under the control of cytomegalovirus immediate-early promoter (CMV) from an E1/partial E3 deleted replication defective recombinant adenovirus, and Ad.sflk-1 expression was determined by Western blotting. We have shown that conditioned media from Ad.sflk-1-infected ARPE-19 cells significantly reduced VEGF-induced human umbilical vein endothelial cells (HUVEC) and murine endothelial cells (SVEC) proliferation in vitro comparedmore » with the control vector. In vivo, adenoviral vectors expressing green fluorescent protein alone (Ad.GFP) were utilized to monitor gene transfer to the cornea. Moreover, in the models of corneal neovascularization, the injection of Ad.sflk-1 (10{sup 8} PFU) into the anterior chamber could significantly inhibit angiogenic changes compared with Ad.null-injected and vehicle-injected models. Immunohistochemical analysis showed that corneal endothelial cells and corneal stroma of cauterized rat eyes were efficiently transduced and expressed sFlk-1. These results not only support that adenoviral vectors are capable of high-level transgene expression but also demonstrate that Ad.sflk-1 gene therapy might be a feasible approach for inhibiting the development of corneal neovascularization.« less

  16. Mechanism of induction of fibroblast to corneal endothelial cell.

    PubMed

    Jiang, Yan; Fu, Wei-Cai; Zhang, Lin

    2014-08-01

    To explore mechanism of nduction of fibroblast to corneal endothelial cell. Rabbit conjunctiva fibroblasts were used as feeder cells, rabbit oral mucosa epithelial cells were used as seed cells, and human denuded amniotic membrane was used as carrier to establish tissue engineering corneal endothelium. The transformation effect was observed. As concentration of mitomycin C increased, cell survival rate gradually decreased, cell proliferation was obviously inhibited when concentration≥25 μg/mL; 5 days after being treated by 5 μg/mL mitomycin C, cell body was enlarged and extended without cell fusion, however after being treated by 0.5 μg/mL mitomycin C, cell body was significantly proliferated and gradually fused; after 3 weeks of culture, stratified epithelium appeared on rabbit oral mucosa epithelial cells, differentiation layers were 4-5 and were well differentiated, the morphology was similar to corneal endothelial cells; Under electron microscope, surface layer of cells were polygonal, tightly connected to another with microvilli on the border, there was hemidesmosome between basal cells and human denuded amniotic membrane. Fibroblast cells have the potential of multi-directional differentiation, effective induction can promote emergence of intercellular desmosomes between seed cells and emergence of epithelial surface microvilli, and differentiate to the corneal endothelial cell. However, clinical application still needs more research and safety evaluation. Copyright © 2014 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  17. Interface fluid syndrome in human eye bank corneas after LASIK: causes and pathogenesis.

    PubMed

    Dawson, Daniel G; Schmack, Ingo; Holley, Glenn P; Waring, George O; Grossniklaus, Hans E; Edelhauser, Henry F

    2007-10-01

    To evaluate the effects of corneal edema on human donor corneas that had previous LASIK using a laboratory model with histologic and ultrastructural correlations. Experimental study. Thirty human eye bank corneas from 15 donors (mean age +/- standard deviation, 49.9+/-8.9 years) who had had previous LASIK surgery (2-8 years before death). The corneas were mounted in an artificial anterior chamber and the corneal endothelium was perfused for up to 5.0 hours with 0.9% saline solution (endothelial cell damage group) or BSS Plus at a pressure of 15 mmHg (control group), or BSS Plus at a pressure of 55 mmHg (high-pressure group). The corneas were evaluated by confocal and specular microscopy before, during, and at the end of the experimental period. Subsequently, the specimens were evaluated by light and electron microscopy. Corneal thickness, reflectivity, histology, and ultrastructure. Endothelial cell damage resulted in an increased (141.5+/-38.8 microm) total corneal thickness relative to controls (52.3+/-33.7 microm), whereas high pressure resulted in a decreased thickness (24.8+/-14.1 microm) relative to controls. This ultimately was due to swelling of the LASIK interface in both groups and swelling of the residual stromal bed (RSB) in the endothelial cell damage group or compression of the RSB and, possibly, the flap in the high-pressure group. A significant increase in corneal reflectivity at the LASIK interface occurred in both groups, primarily due to varying degrees of fluid accumulation and associated hydropic keratocyte degeneration, as well as increased corneal reflectivity in the RSB only in the endothelial cell damage group. After LASIK surgery, edematous corneas preferentially hydrate and swell in the paracentral and central interface wound, commonly resulting in a hazy corneal appearance primarily due to keratocyte hydropic degeneration. More severe corneal edema is characterized by the formation of an optically empty space corresponding to an interface fluid pocket. The spectrum of interface fluid syndrome can be described in 3 stages.

  18. Inverse cutting of posterior lamellar corneal grafts by a femtosecond laser.

    PubMed

    Hjortdal, Jesper; Nielsen, Esben; Vestergaard, Anders; Søndergaard, Anders

    2012-01-01

    Posterior lamellar grafting of the cornea has become the preferred technique for treatment of corneal endothelial dysfunction. Posterior lamellar grafts are usually cut by a micro-keratome or a femto-second laser after the epithelial side of the donor cornea has been applanated. This approach often results in variable central graft thickness in different grafts and an increase in graft thickness towards the periphery in every graft. The purpose of this study was to evaluate if posterior lamellar grafts can be prepared from the endothelial side by a femto-second laser, resulting in reproducible, thin grafts of even thickness. A CZM 500 kHz Visumax femto-second laser was used. Organ cultured donor grafts were mounted in an artifical anterior chamber with the endothelial side up and out. Posterior grafts of 7.8 mm diameter and 130 micron thickness were prepared by femto-second laser cutting. A standard DSAEK procedure was performed in 10 patients with Fuchs endothelial dystrophy. Patients were followed-up regularly and evaluated by measurement of complications, visual acuity, corneal thickness (Pentacam HR), and endothelial cell density. Femto-laser cutting of grafts and surgery was uncomplicated. Rebubbling was necessary in 5 of 10 cases (normally only in 1 of 20 cases). All grafts were attached and cleared up during the first few weeks. After six months, the average visual acuity was 0.30 (range: 0.16 to 0.50), corneal thickness was 0.58 mm (range 0.51 to 0.63), and endothelial cell density was 1.570 per sq. mm (range: 1.400 to 2.000 cells per sq. mm). The grafts were of uniform thickness, but substantial interface haze was present in most grafts. Posterior lamellar corneal grafts can be prepared from the endothelial side using a femto-second laser. All grafts were clear after 6 months with satisfying endothelial cell counts. Poor visual acuity caused by interface scatter was observed in most patients. Femto-second laser cutting parameters needs to be optimised to enable smooth cutting in the posterior stroma.

  19. Inverse Cutting of Posterior Lamellar Corneal Grafts by a Femtosecond Laser

    PubMed Central

    Hjortdal, Jesper; Nielsen, Esben; Vestergaard, Anders; Søndergaard, Anders

    2012-01-01

    Purpose Posterior lamellar grafting of the cornea has become the preferred technique for treatment of corneal endothelial dysfunction. Posterior lamellar grafts are usually cut by a micro-keratome or a femto-second laser after the epithelial side of the donor cornea has been applanated. This approach often results in variable central graft thickness in different grafts and an increase in graft thickness towards the periphery in every graft. The purpose of this study was to evaluate if posterior lamellar grafts can be prepared from the endothelial side by a femto-second laser, resulting in reproducible, thin grafts of even thickness. Methods A CZM 500 kHz Visumax femto-second laser was used. Organ cultured donor grafts were mounted in an artifical anterior chamber with the endothelial side up and out. Posterior grafts of 7.8 mm diameter and 130 micron thickness were prepared by femto-second laser cutting. A standard DSAEK procedure was performed in 10 patients with Fuchs endothelial dystrophy. Patients were followed-up regularly and evaluated by measurement of complications, visual acuity, corneal thickness (Pentacam HR), and endothelial cell density. Results Femto-laser cutting of grafts and surgery was uncomplicated. Rebubbling was necessary in 5 of 10 cases (normally only in 1 of 20 cases). All grafts were attached and cleared up during the first few weeks. After six months, the average visual acuity was 0.30 (range: 0.16 to 0.50), corneal thickness was 0.58 mm (range 0.51 to 0.63), and endothelial cell density was 1.570 per sq. mm (range: 1.400 to 2.000 cells per sq. mm). The grafts were of uniform thickness, but substantial interface haze was present in most grafts. Conclusions Posterior lamellar corneal grafts can be prepared from the endothelial side using a femto-second laser. All grafts were clear after 6 months with satisfying endothelial cell counts. Poor visual acuity caused by interface scatter was observed in most patients. Femto-second laser cutting parameters needs to be optimised to enable smooth cutting in the posterior stroma. PMID:22582107

  20. "All-laser" endothelial corneal transplant in human patients

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Menabuoni, Luca; Malandrini, Alex; Canovetti, Annalisa; Lenzetti, Ivo; Pini, Roberto

    2012-03-01

    Femtosecond laser sculpturing of corneal tissue is commonly used for the preparation of endothelial flaps. Diode laser welding of ocular tissues is a procedure that enables minimally invasive suturing of tissues. The combination of these laser based techniques results in a new approach to minimally invasive ophthalmic surgery, such as in endothelial corneal transplant (or endothelial keratoplasty - EK). In this work we present the "all laser" EK performed in human subjects. 24 pseudophakic patients with bullous keratopathy underwent EK: the femtosecond laser was used to prepare the 100 ìm thick and 8.5 mm diameter donor Descemet endothelial flap. After staining the stromal layer of the donor flap with a liquid ICG solution, the donor flap was inserted in the recipient eye by the use of the Busin injector. Then, the endothelial layer was laser-welded to the recipient eye (10 laser spots around the periphery of the flap), in order to reduce the risk of postoperative dislocation of the transplanted flap. A transplanted flap engraftment was observed in all the treated eyes. The staining procedure used to perform laser welding also enabled to evidence the stromal side of the donor flap, so as the flap was always placed in the right side position. The endothelial cells counts in both the laserwelded flaps and in a control group were in good agreement. The proposed technique is easy to perform and enables the reduction of postoperative endothelial flap dislocations.

  1. Diagnosis and Management of Iridocorneal Endothelial Syndrome

    PubMed Central

    Sacchetti, Marta; Mantelli, Flavio; Macchi, Ilaria; Ambrosio, Oriella; Rama, Paolo

    2015-01-01

    The iridocorneal endothelial (ICE) syndrome is a rare ocular disorder that includes a group of conditions characterized by structural and proliferative abnormalities of the corneal endothelium, the anterior chamber angle, and the iris. Common clinical features include corneal edema, secondary glaucoma, iris atrophy, and pupillary anomalies, ranging from distortion to polycoria. The main subtypes of this syndrome are the progressive iris atrophy, the Cogan-Reese syndrome, and the Chandler syndrome. ICE syndrome is usually diagnosed in women in the adult age. Clinical history and complete eye examination including tonometry and gonioscopy are necessary to reach a diagnosis. Imaging techniques, such as in vivo confocal microscopy and ultrasound biomicroscopy, are used to confirm the diagnosis by revealing the presence of “ICE-cells” on the corneal endothelium and the structural changes of the anterior chamber angle. An early diagnosis is helpful to better manage the most challenging complications such as secondary glaucoma and corneal edema. Treatment of ICE-related glaucoma often requires glaucoma filtering surgery with antifibrotic agents and the use of glaucoma drainage implants should be considered early in the management of these patients. Visual impairment and pain associated with corneal edema can be successfully managed with endothelial keratoplasty. PMID:26451377

  2. Applications of Biomaterials in Corneal Endothelial Tissue Engineering.

    PubMed

    Wang, Tsung-Jen; Wang, I-Jong; Hu, Fung-Rong; Young, Tai-Horng

    2016-11-01

    When corneal endothelial cells (CECs) are diseased or injured, corneal endothelium can be surgically removed and tissue from a deceased donor can replace the original endothelium. Recent major innovations in corneal endothelial transplantation include replacement of diseased corneal endothelium with a thin lamellar posterior donor comprising a tissue-engineered endothelium carried or cultured on a thin substratum with an organized monolayer of cells. Repairing CECs is challenging because they have restricted proliferative ability in vivo. CECs can be cultivated in vitro and seeded successfully onto natural tissue materials or synthetic polymeric materials as grafts for transplantation. The optimal biomaterials for substrata of CEC growth are being investigated. Establishing a CEC culture system by tissue engineering might require multiple biomaterials to create a new scaffold that overcomes the disadvantages of single biomaterials. Chitosan and polycaprolactone are biodegradable biomaterials approved by the Food and Drug Administration that have superior biological, degradable, and mechanical properties for culturing substratum. We successfully hybridized chitosan and polycaprolactone into blended membranes, and demonstrated that CECs proliferated, developed normal morphology, and maintained their physiological phenotypes. The interaction between cells and biomaterials is important in tissue engineering of CECs. We are still optimizing culture methods for the maintenance and differentiation of CECs on biomaterials.

  3. The endothelial sample size analysis in corneal specular microscopy clinical examinations.

    PubMed

    Abib, Fernando C; Holzchuh, Ricardo; Schaefer, Artur; Schaefer, Tania; Godois, Ronialci

    2012-05-01

    To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab. A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE < 0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Bio-Optics: sample size, 97 ± 22 cells; RE, 6.52 ± 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE < 0.05); customized sample size, 162 ± 34 cells. CSO: sample size, 110 ± 20 cells; RE, 5.98 ± 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE < 0.05); customized sample size, 157 ± 45 cells. Konan: sample size, 80 ± 27 cells; RE, 10.6 ± 3.67; none of the examinations had sufficient endothelial cell quantity (RE > 0.05); customized sample size, 336 ± 131 cells. Topcon: sample size, 87 ± 17 cells; RE, 10.1 ± 2.52; none of the examinations had sufficient endothelial cell quantity (RE > 0.05); customized sample size, 382 ± 159 cells. A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.

  4. Endothelial quality of pre-cut posterior corneal lamellae for Descemet membrane endothelial keratoplasty with a stromal rim (DMEK-S): two-year outcome of manual preparation in an ocular tissue bank.

    PubMed

    Krabcova, Ivana; Studeny, Pavel; Jirsova, Katerina

    2013-06-01

    To assess the quantitative and qualitative parameters of pre-cut posterior corneal lamellae for Descemet membrane endothelial keratoplasty with a stromal rim (DMEK-S) prepared manually in the Ocular Tissue Bank Prague. All 65 successfully prepared pre-cut posterior corneal lamellae provided for grafting during a 2-year period were analyzed retrospectively. The lamellae, consisting of a central zone of endothelium-Descemet membrane surrounded by a supporting peripheral stromal rim, were prepared manually from corneoscleral buttons having an endothelial cell density higher than 2,500 cells/mm(2). The live endothelial cell density, the percentage of dead cells, the hexagonality and the coefficient of variation were assessed before and immediately after preparation as well as after 2 days of organ culture storage at 31 °C. Altogether, the endothelium of 57 lamellae was assessed. Immediately after preparation, the mean live endothelial cell density was 2,835 cells/mm(2) and, on average, 1.8 % of dead cells were found. After 2 days of storage, the cell density decreased significantly to 2,757 cells/mm(2) and the percentage of dead cells to 1.0 %. There was a significant change in the mean hexagonality and the coefficient of variation after lamellar preparation and subsequent storage. The amount of tissue wasted during the preparation was 23 %. The endothelial cell density of posterior corneal lamellae sent for DMEK-S was higher than 2,700 cells/mm(2) in average with a low percentage of dead cells; 65 pre-cut tissues were used for grafting during a 2-year period.

  5. Frequency of Complications During Preparation of Corneal Lamellae Used in Posterior Lamellar Keratoplasty Using the Pneumodissection Technique (Big Bubble).

    PubMed

    Studeny, Pavel; Netukova, Magdalena; Hlozanek, Martin; Bednar, Jan; Jirsova, Katerina; Krizova, Deli

    2018-04-26

    To determine the frequency of formation of various types of bubbles and the potential impact of donor and lamella parameters on this frequency, and to identify possible risk factors of unsuccessful "big-bubble" creation in preparation of pre-Descemet endothelial keratoplasty and Descemet membrane endothelial keratoplasty with peripheral stromal support. Donor age and sex, death to preservation time (DPT), storage time, presence of corneal scars (mainly a condition after cataract surgery), and endothelial cell density of 256 donor corneas were assessed before Descemet membrane endothelial keratoplasty with peripheral stromal support or pre-Descemet endothelial keratoplasty lamella preparation using the big-bubble technique. Mean donor age was 62.3 ± 8.5 years (28.3% women and 71.7% men). Mean endothelial cell density of the donor graft was 2866 ± 255 cells/mm. Mean DPT was 10.12 ± 4.88 hours, and mean storage time of the transplant before surgery was 6.5 ± 4.8 days. Corneal scars were present in 17 donor grafts (6.6%) after cataract surgery. Eleven corneas were devalued because of Descemet membrane rupture during preparation (4.3%). In 182 corneas, standard bubble type I was created (71.7%); in 27 corneas, bubble type II was created; eventually, both types of bubbles formed simultaneously (10.5%); in 47 corneas, no bubble was created (18.4%). We identified higher endothelial cell density, shorter DPT, and the presence of corneal scars after cataract surgery as risk factors threatening successful bubble formation. The only risk factor for creating type II bubbles was higher donor age in our study.

  6. A chandelier-illuminated anterior chamber maintainer for use during descemet stripping automated endothelial keratoplasty in patients with advanced bullous keratopathy.

    PubMed

    Inoue, Tomoyuki; Oshima, Yusuke; Hori, Yuich; Maeda, Naoyuki

    2010-08-01

    A new 25-gauge illuminated anterior chamber maintainer composed of a 25-gauge infusion cannula through which a 29-gauge chandelier fiber probe passes was developed for use during Descemet stripping automated endothelial keratoplasty to treat patients with advanced bullous keratopathy. This device, which is compatible with a xenon or mercury vapor illuminator to generate powerful wide-angle illumination from the cone-shaped chandelier fiber tip, is self-retained at the corneal limbus after insertion of the infusion cannula through a corneal side port. Because of its bifunctionality, that is, bright illumination and adequate irrigation flow, excellent visibility with stable anterior chamber maintenance can be concurrently obtained for Descemet stripping, endothelial graft insertion, and subsequent intraocular manipulations without the need for use of a biologic staining technique or ophthalmic viscosurgical products even in patients with severe corneal haze. This new device facilitates safe and simple intraocular manipulation during Descemet stripping automated endothelial keratoplasty.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu Jiawei; Division of Molecular Medicine, Harbor-UCLA Medical Center, David Geffen School of Medicine, University of California Los Angeles, Torrance, CA 90502; Lu Zhenyu

    The corneal endothelial cells form a boundary layer between anterior chamber and cornea. This single cell layer is important to maintain cornea transparency by eliciting net fluid transport into the anterior chamber. Injuries of the corneal endothelial layer in humans lead to corneal swelling and translucence. This hindrance is thought to be due to limited proliferative capacity of the endothelial layer. Fibroblast growth factor 2 (FGF-2) and transforming growth factor-beta 2 (TGF-{beta}2) are both found in aqueous humor, and these two cytokines promote and inhibit cell growth, respectively. The intracellular signaling mechanisms by which TGF-{beta}2 suppresses the mitogenic response tomore » FGF-2, however, remain unclear. We have addressed this question by investigating potential crosstalk between FGF-2-induced and TGF-{beta}2-regulated intracellular signaling events in cultured bovine corneal endothelial (BCE) cells. We found that TGF-{beta}2 and FGF-2 oppositely affect BCE cell proliferation and TGF-{beta}2 can override the stimulating effects of FGF-2 by increasing COX-2 expression in these cells. Consistent with these findings, overexpression of COX-2 significantly reduced FGF-2-induced cell proliferation whereas a COX-2 specific inhibitor NS398 reversed the effect of TGF-{beta}2 on FGF-2-induced cell proliferation. The COX-2 product prostaglandin E2 (PGE-2) blocks FGF-2-induced cell proliferation. Whereas FGF-2 stimulates cell proliferation by activating the AKT pathway, TGF-{beta}2 and PGE-2 both inhibit this pathway. In accordance with the effect of PGE-2, cAMP also inhibits FGF-2-induced AKT activation. These findings suggest that the mitogenic response to FGF-2 in vivo in the corneal endothelial layer may be inhibited by TGF-{beta}2-induced suppression of the PI3-kinase/AKT signaling pathway.« less

  8. [Confocal microscopy findings after endothelial transplant by DSAEK].

    PubMed

    Ramírez, Manuel; Ortiz, Claudia; Dewit-Carter, Guillermo; Hernández-Quintela, Everardo

    2018-01-01

    To evaluate early in vivo corneal wound healing findings after Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) by using in vivo confocal microscopy. A total of 15 eyes of 15 patients were included. In vivo confocal microscopy (Confoscan 4, Fortune Technologies, Italy) was performed from 4 to 7 weeks after DSAEK. Measurements were scanned from the corneal endothelium to the corneal surface with a Navis® software (NIDEK, Multi-Instrument Diagnostic System, Japan). Donor-receptor interface was found in an average of 114 ± 12.4 microns. Corneal stromal folds were observed from 111.1 ± 3.5 microns from the endothelium to 286 ± 94 microns (mean 175 ± 90.5 microns of the corneal stroma). Keratocites were activated in the donor tissue from 12 ± 1.4 microns from the endothelium to 105 ± 38.2 microns (mean 93 ± 36.9 microns of the corneal stroma). Donor keratocites are activated up to 7 weeks after DSAEK. Several corneal folds are present in proximity to the donor-receptor interface after DSAEK. Further evaluation of these findings is justified to determine its clinical significance. Copyright: © 2018 Permanyer.

  9. The comparative safety of genipin versus UVA-riboflavin crosslinking of rabbit corneas

    PubMed Central

    Song, Wenjing; Tang, Yun; Qiao, Jing; Li, Haili; Rong, Bei; Yang, Songlin; Wu, Yuan

    2017-01-01

    Purpose To investigate, after 24 h, the safety of genipin or ultraviolet A (UVA)-riboflavin crosslinking of keratocytes and endothelial cells. Methods Fifteen New Zealand white rabbits were selected and divided into a PBS group (five rabbits), a 0.2% genipin crosslinking (GP-CXL) group (five rabbits), and a UVA-riboflavin crosslinking (UVA-CXL) group (five rabbits). In the GP-CXL and PBS groups, 0.2% genipin or PBS was applied to the corneal surface of the right eyes. In the UVA-CXL group, a clinical crosslinking procedure was used. Before and after surgery, the operated eyes of each group were characterized with confocal microscopy, and the corneal buttons were excised for endothelium staining and electron microscopy. Results The corneal endothelial cell density of the GP-CXL, UVA-CLX, and PBS groups changed. There was a statistically significant difference in thickness and changes in corneal endothelial cell density between the UVA-CXL group and the PBS group (p<0.05), and between the UVA-CXL group and the GP-CXL group (p<0.05), but no statistically significant difference between the GP-CXL group and the PBS group. Confocal microscopy, transmission electron microscopy, and hematoxylin and eosin staining showed that there was keratocyte apoptosis in the anterior and middle stroma and endothelial cell damage in the UVA-CXL group. In the GP-CXL group, only active keratocytes were found and minimal endothelial cell damage. Conclusions Treatment of rabbit corneas with 0.2% genipin showed minimal toxicity toward keratocytes and endothelial cells. Genipin is safer than UVA-CXL for crosslinking of thin corneas. PMID:28761323

  10. In vitro biomimetic platforms featuring a perfusion system and 3D spheroid culture promote the construction of tissue-engineered corneal endothelial layers.

    PubMed

    Li, Shanyi; Han, Yuting; Lei, Hao; Zeng, Yingxin; Cui, Zekai; Zeng, Qiaolang; Zhu, Deliang; Lian, Ruiling; Zhang, Jun; Chen, Zhe; Chen, Jiansu

    2017-04-10

    Corneal endothelial cells (CECs) are very important for the maintenance of corneal transparency. However, in vitro, CECs display limited proliferation and loss of phenotype via endothelial to mesenchymal transformation (EMT) and cellular senescence. In this study, we demonstrate that continuous supplementary nutrition using a perfusion culture bioreactor and three-dimensional (3D) spheroid culture can be used to improve CEC expansion in culture and to construct a tissue-engineered CEC layer. Compared with static culture, perfusion-derived CECs exhibited an increased proliferative ability as well as formed close cell-cell contact junctions and numerous surface microvilli. We also demonstrated that the CEC spheroid culture significantly down-regulated gene expression of the proliferation marker Ki67 and EMT-related markers Vimentin and α-SMA, whereas the gene expression level of the CEC marker ATP1A1 was significantly up-regulated. Furthermore, use of the perfusion system in conjunction with a spheroid culture on decellularized corneal scaffolds and collagen sheets promoted the generation of CEC monolayers as well as neo-synthesized ECM formation. This study also confirmed that a CEC spheroid culture on a curved collagen sheet with controlled physiological intraocular pressure could generate a CEC monolayer. Thus, our results show that the use of a perfusion system and 3D spheroid culture can promote CEC expansion and the construction of tissue-engineered corneal endothelial layers in vitro.

  11. Cornea Preservation Time Study: Methods and Potential Impact on the Cornea Donor Pool in the United States

    PubMed Central

    Szczotka-Flynn, Loretta B.; Ayala, Allison R.; Benetz, Beth A.; Gal, Robin L.; Aldave, Anthony J.; Corrigan, Michelle M.; Dunn, Steven P.; McCall, Ty L.; Pramanik, Sudeep; Rosenwasser, George O.; Ross, Kevin W.; Terry, Mark A.; Verdier, David D.

    2015-01-01

    Purpose: The aim of this study was to describe the aims, methods, donor and recipient cohort characteristics, and potential impact of the Cornea Preservation Time Study (CPTS). Methods: The CPTS is a randomized clinical trial conducted at 40 clinical sites (70 surgeons) designed to assess the effect of donor cornea preservation time (PT) on graft survival 3 years after Descemet stripping automated endothelial keratoplasty (DSAEK). Eyes undergoing surgery for Fuchs endothelial corneal dystrophy or pseudophakic/aphakic corneal edema were randomized to receive donor corneas stored ≤7 days or 8 to 14 days. Donor and patient characteristics, tissue preparation and surgical parameters, recipient and donor corneal stroma clarity, central corneal thickness, intraocular pressure, complications, and a reading center-determined central endothelial cell density were collected. Surveys were conducted to evaluate pre-CPTS PT practices. Results: The 1330 CPTS donors were: 49% >60 years old, 27% diabetic, had a median eye bank–determined screening endothelial cell density of 2688 cells/mm2, and 74% eye bank prepared for DSAEK. A total of 1090 recipients (1330 eyes including 240 bilateral cases) had: median age of 70 years, were 60% female, 90% white, 18% diabetic, 52% phakic, and 94% had Fuchs endothelial corneal dystrophy. Before the CPTS, 19 eye banks provided PT data on 20,852 corneas domestically placed for DSAEK in 2010 to 2011; 96% were preserved ≤7 days. Of 305 American Academy of Ophthalmology members responding to a pre-CPTS survey, 233 (76%) set their maximum PT preference at 8 days or less. Conclusions: The CPTS will increase understanding of factors related to DSAEK success and, if noninferiority of longer PT is shown, will have great potential to extend the available pool of endothelial keratoplasty donors. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT01537393. PMID:25850706

  12. The effect of topical application of 0.15% ganciclovir gel on cytomegalovirus corneal endotheliitis.

    PubMed

    Koizumi, Noriko; Miyazaki, Dai; Inoue, Tomoyuki; Ohtani, Fumie; Kandori-Inoue, Michiko; Inatomi, Tsutomu; Sotozono, Chie; Nakagawa, Hiroko; Horikiri, Tomoko; Ueta, Mayumi; Nakamura, Takahiro; Inoue, Yoshitsugu; Ohashi, Yuichi; Kinoshita, Shigeru

    2017-02-01

    The aim of this study was to evaluate the therapeutic efficacy and drug transfer of topical application of 0.15% ganciclovir (GCV) gel on cytomegalovirus (CMV) corneal endotheliitis. This study is a multicentre, prospective, interventional case series. Seven eyes of seven immunocompetent patients diagnosed with CMV corneal endotheliitis, based on clinical manifestations and qualitative PCR, were enrolled in this study. The patients were treated with topical applications of 0.15% GCV gel six times daily for 12 weeks without concomitant systemic GCV. Clinical evaluations and quantitative PCR of CMV were performed, and GCV concentrations in aqueous humour were measured by liquid chromatography/tandem mass spectrometry. Clinical improvement of coin-shaped lesions, other types of keratic precipitates, corneal oedema, and anterior chamber inflammation was confirmed at the 4-week visit in all seven eyes. The GCV treatment significantly decreased the CMV copy numbers (p<0.0001). After 12 weeks of treatment, six eyes recovered clear corneas with good vision, and endothelial function was well maintained. Detectable levels of GCV were confirmed in the aqueous humour of all the eyes. The mean GCV concentration in the anterior chamber was 162.0±202.4 ng/mL. The re-emergence of CMV without symptoms was observed in one eye with lower drug transfer. No side effects were observed. Clinical improvement and reduced CMV copy numbers in the aqueous humour were confirmed in the CMV corneal endotheliitis cases. Although the case numbers are limited and long-term follow-up is necessary, the topical application of 0.15% GCV gel appears to be a useful treatment option for CMV endotheliitis. UMIN000012435. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. An Adult Case of Fulminant Mumps Keratitis With Positive Viral RNA in Aqueous Humor Detected by RT-PCR.

    PubMed

    Shibata, Teppei; Takahashi, Yoriko; Okamoto, Ayako; Sasaki, Hiroshi; Kitagawa, Kazuko

    2016-04-01

    To report an adult case of mumps keratitis with mumps virus in aqueous humor and decreased corneal endothelial cell density. Case report. A 60-year-old female with a 39°C fever and bilateral parotid swelling diagnosed with mumps and treated for photophobia, pain, redness, and decreased vision in 1 eye, was referred to our hospital when her condition deteriorated despite receiving betamethasone phosphate instillation and antiglaucoma agents for elevated intraocular pressure (52 mm Hg) and iritis. Her right eye was normal, whereas her left eye showed 20/400 visual acuity, 21 mm Hg intraocular pressure, ciliary injection and edema, opacity, and Descemet folds in the entire cornea. Round white keratic precipitates were present on the posterior corneal surface, whereas anterior chamber cells could not be examined in detail because of corneal edema. Mumps virus was detected by reverse transcriptase polymerase chain reaction in an aqueous humor sample taken at the time of admission. Following diagnosis of keratitis, administration of 30 mg oral prednisolone daily and frequent instillation of betamethasone phosphate steadily improved her corneal edema and opacity. In her left eye, visual acuity recovered to 20/16 and keratitis was resolved at 4 weeks; however, corneal endothelial cell density was significantly decreased to less than 400 per square millimeter. Mumps keratitis may cause severe corneal endothelial cell loss.

  14. Corneal Opacity in Domestic Ducks Experimentally Infected With H5N1 Highly Pathogenic Avian Influenza Virus.

    PubMed

    Yamamoto, Y; Nakamura, K; Yamada, M; Mase, M

    2016-01-01

    Domestic ducks can be a key factor in the regional spread of H5N1 highly pathogenic avian influenza (HPAI) virus in Asia. The authors performed experimental infections to examine the relationship between corneal opacity and H5N1 HPAI virus infection in domestic ducks (Anas platyrhyncha var domestica). A total of 99 domestic ducks, including 3 control birds, were used in the study. In experiment 1, when domestic ducks were inoculated intranasally with 2 H5N1 HPAI viruses, corneal opacity appeared more frequently than neurologic signs and mortality. Corneal ulceration and exophthalmos were rare findings. Histopathologic examinations of the eyes of domestic ducks in experiment 2 revealed that corneal opacity was due to the loss of corneal endothelial cells and subsequent keratitis with edema. Influenza viral antigen was detected in corneal endothelial cells and some other ocular cells by immunohistochemistry. Results suggest that corneal opacity is a characteristic and frequent finding in domestic ducks infected with the H5N1 HPAI virus. Confirming this ocular change may improve the detection rate of infected domestic ducks in the field. © The Author(s) 2015.

  15. Effect of chemical composition on corneal cellular response to photopolymerized materials comprising 2-hydroxyethyl methacrylate and acrylic acid.

    PubMed

    Lai, Jui-Yang

    2013-10-01

    Characterization of corneal cellular response to hydrogel materials is an important issue in ophthalmic applications. In this study, we aimed to investigate the relationship between the feed composition of 2-hydroxyethyl methacrylate (HEMA)/acrylic acid (AAc) and material compatibility towards corneal stromal and endothelial cells. The monomer solutions of HEMA and AAc were mixed at varying volume ratios of 92:0, 87:5, 82:10, 77:15, and 72:20, and were subjected to UV irradiation. Results of electrokinetic measurements showed that an increase in absolute zeta potential of photopolymerized membranes is observed with increasing the volume ratios of AAc/HEMA. Following 4 days of incubation with various hydrogels, the primary rabbit corneal stromal and endothelial cell cultures were examined for viability, proliferation, and pro-inflammatory gene expression. The samples prepared from the solution mixture containing 0-10 vol.% AAc displayed good cytocompatibility. However, with increasing volume ratio of AAc and HEMA from 15:77 to 20:72, the decreased viability, inhibited proliferation, and stimulated inflammation were noted in both cell types, probably due to the stronger charge-charge interactions. On the other hand, the ionic pump function of corneal endothelial cells exposed to photopolymerized membranes was examined by analyzing the Na(+),K(+)-ATPase alpha 1 subunit (ATP1A1) expression level. The presence of material samples having higher anionic charge density (i.e., zeta potential of -38 to -56 mV) may lead to abnormal transmembrane transport. It is concluded that the chemical composition of HEMA/AAc has an important influence on the corneal stromal and endothelial cell responses to polymeric biomaterials. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Corneal toxicity after Ozurdex(®) migration into anterior chamber.

    PubMed

    Bernal, L; Estévez, B

    2016-06-01

    To describe a case of corneal toxicity after migration of a dexamethasone implant into the anterior chamber. A 62-year-old man with aphakia and a history of vitrectomy received a dexamethasone implant for a refractory Irvine-Gass syndrome. Thirty days later, the implant migrated into the anterior chamber causing endothelial contact with secondary corneal oedema that justified the removal of the implant without resolution of the oedema. Clinical tolerability to dislocated implant is poor in cases with pre-existing corneal oedema, and because of this, it must be removed early. In cases of aphakia and vitrectomy, the increased risk of Ozurdex(®) dislocation justifies performing a prior endothelial count. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  17. Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification.

    PubMed

    Módis, László Jr; Szalai, Eszter; Flaskó, Zsuzsa; Németh, Gábor

    2016-01-01

    To study the endothelial cell morphology and corneal thickness changes after phacoemulsification by using the OZil torsional and longitudinal ultrasound techniques (Infiniti Vision System, Alcon Laboratories). Department of Ophthalmology, Clinical Center, University of Debrecen, Debrecen, Hungary. 52 patients with cataract were randomly assigned to longitudinal ultrasound and torsional mode group. All surgeries were performed through a 2.2 mm clear corneal incision, the method employed being divide and conquer. The endothelial morphometry such as cell density (ECD), mean cell area, coefficient of variation of cell area, and central corneal thickness were examined with specular microscopy (EM-1000, Tomey) preoperatively and 4, 8 weeks postoperatively. ECD values decreased significantly in both surgical groups (P < .001, repeated- mesures ANOVA), the postoperative endothelial cell loss was higher in the longitudinal ultrasound mode group (3.5% and 6.5%, at 4 and 8 weeks after surgery) than in the torsional group (3.3% and 5.5%, at 4 and 8 weeks after surgery), the difference not being significant between the two groups (P = .164 and P = .479, at 4 and 8 weeks after surgery, Mann-Whitney test). There was no statistically significant difference in any of the assessed parameters between the two surgical groups (P > .05). No significant correlation was found between the endothelial cell loss and the nucleus density. Both phacoemulsification techniques were safe and effective. The torsional handpiece performs oscillatory movements and delivers less energy into the eye than the longitudinal ultrasound technique, therefore providing more favorable energy and thermal safety profile.

  18. Fully automated corneal endothelial morphometry of images captured by clinical specular microscopy

    NASA Astrophysics Data System (ADS)

    Bucht, Curry; Söderberg, Per; Manneberg, Göran

    2010-02-01

    The corneal endothelium serves as the posterior barrier of the cornea. Factors such as clarity and refractive properties of the cornea are in direct relationship to the quality of the endothelium. The endothelial cell density is considered the most important morphological factor of the corneal endothelium. Pathological conditions and physical trauma may threaten the endothelial cell density to such an extent that the optical property of the cornea and thus clear eyesight is threatened. Diagnosis of the corneal endothelium through morphometry is an important part of several clinical applications. Morphometry of the corneal endothelium is presently carried out by semi automated analysis of pictures captured by a Clinical Specular Microscope (CSM). Because of the occasional need of operator involvement, this process can be tedious, having a negative impact on sampling size. This study was dedicated to the development and use of fully automated analysis of a very large range of images of the corneal endothelium, captured by CSM, using Fourier analysis. Software was developed in the mathematical programming language Matlab. Pictures of the corneal endothelium, captured by CSM, were read into the analysis software. The software automatically performed digital enhancement of the images, normalizing lights and contrasts. The digitally enhanced images of the corneal endothelium were Fourier transformed, using the fast Fourier transform (FFT) and stored as new images. Tools were developed and applied for identification and analysis of relevant characteristics of the Fourier transformed images. The data obtained from each Fourier transformed image was used to calculate the mean cell density of its corresponding corneal endothelium. The calculation was based on well known diffraction theory. Results in form of estimated cell density of the corneal endothelium were obtained, using fully automated analysis software on 292 images captured by CSM. The cell density obtained by the fully automated analysis was compared to the cell density obtained from classical, semi-automated analysis and a relatively large correlation was found.

  19. Comparison of torsional and microburst longitudinal phacoemulsification: a prospective, randomized, masked clinical trial.

    PubMed

    Vasavada, Abhay R; Raj, Shetal M; Patel, Udayan; Vasavada, Vaishali; Vasavada, Viraj

    2010-01-01

    To compare intraoperative performance and postoperative outcome of three phacoemulsification technologies in patients undergoing microcoaxial phacoemulsification through 2.2-mm corneal incisions. The prospective, randomized, single-masked study included 360 eyes randomly assigned to torsional (Infiniti Vision System; Alcon Laboratories, Fort Worth, TX), microburst with longitudinal (Infiniti), or microburst with longitudinal (Legacy Everest, Alcon Laboratories) ultrasound. Assessments included surgical clock time, fluid volume, and intraoperative complications, central corneal thickness on day 1 and months 1 and 3 postoperatively, and endothelial cell density at 3 months postoperatively. Comparisons among groups were conducted. Torsional ultrasound required significantly less surgical clock time and fluid volume than the other groups. There were no intraoperative complications. Change in central corneal thickness and endothelial cell loss was significantly lower in the torsional ultrasound group at all postoperative visits (P < .001, Kruskal-Wallis test) compared to microburst longitudinal ultrasound modalities. Torsional ultrasound demonstrated quantitatively superior intraoperative performance and showed less increase in corneal thickness and less endothelial cell loss compared to microburst longitudinal ultrasound. Copyright 2010, SLACK Incorporated.

  20. Association of the Gutta-Induced Microenvironment With Corneal Endothelial Cell Behavior and Demise in Fuchs Endothelial Corneal Dystrophy.

    PubMed

    Kocaba, Viridiana; Katikireddy, Kishore Reddy; Gipson, Ilene; Price, Marianne O; Price, Francis W; Jurkunas, Ula V

    2018-05-31

    The number and size of guttae increase over time in Fuchs endothelial corneal dystrophy (FECD); however, the association between these physical parameters and disease pathogenesis is unclear. To determine the role of guttae in corneal endothelial cell function. In an in vitro model, cells from a human corneal endothelial cell line, HCENC-21T, were seeded on decellularized normal (n = 30) and FECD (n = 70) endothelial basement (Descemet) membranes (DMs). Normal human corneas were sent to our laboratory from 3 sources. The study took place at the Schepens Eye Research Institute, Massachusetts Eye and Ear, Boston, and was performed from September 2015 to July 2017. Normal DMs were obtained from 3 different tissue banks and FECD-DMs were obtained from patients undergoing endothelial keratoplasty in 2 departments. Endothelial cell shape, growth, and migration were assessed by live-cell imaging, and gene expression analysis as a function of guttae diameter was assessed by laser capture microscopy. Mean (SD) age of normal-DMs donors was 65.6 (4.4) years (16 women [53%]), and mean (SD) age of FECD-DMs donors was 68.9 (10.6) years (43 women [61%]). Cells covered a greater area (mean [SD], 97.7% [8.5%]) with a greater mean (SD) number of cells (2083[153] cells/mm2) on the normal DMs compared with the FECD DMs (72.8% [11%]; P = .02 and 1541 [221] cells/mm2 221/mm2; P = .01, respectively). Differences in endothelial cell growth over guttae were observed on FECD DMs depending on the guttae diameter. Guttae with a mean (SD) diameter of 10.5 (2.9) μm did not impede cell growth, whereas those with a diameter of 21.1 (4.9) μm were covered only by the cell cytoplasm. Guttae with the largest mean (SD) diameter, 31.8 (3.8) μm, were not covered by cells, which instead surrounded them in a rosette pattern. Moreover, cells adjacent to large guttae upregulated αSMA, N-cadherin, Snail1, and NOX4 genes compared with ones grown on normal DMs or small guttae. Furthermore, large guttae induced TUNEL-positive apoptosis in a rosette pattern, similar to ex vivo FECD specimens. These findings highlight the important role of guttae in endothelial cell growth, migration, and survival. These data suggest that cell therapy procedures in FECD might be guided by the diameter of the host guttae if subsequent clinical studies confirm these laboratory findings.

  1. Early Corneal Cellular and Nerve Fiber Pathology in Young Patients With Type 1 Diabetes Mellitus Identified Using Corneal Confocal Microscopy.

    PubMed

    Szalai, Eszter; Deák, Eszter; Módis, László; Németh, Gábor; Berta, András; Nagy, Annamária; Felszeghy, Eniko; Káposzta, Rita; Malik, Rayaz A; Csutak, Adrienne

    2016-03-01

    The aim of this study was to quantify epithelial, stromal, and endothelial cell density, and subbasal nerve morphology in young patients with type 1 diabetes mellitus with and without diabetic retinopathy. A total of 28 young patients (mean age, 22.86 ± 9.05 years) with type 1 diabetes, with (n = 18) and without (n = 10) retinopathy, and 17 age-matched healthy control subjects (mean age, 26.53 ± 2.43 years) underwent corneal confocal microscopy (CCM). We found significantly lower epithelial (P < 0.0001) and endothelial (P = 0.001) cell densities and higher keratocyte cell density (P = 0.024) in patients with type 1 diabetes compared to controls. Significantly lower corneal nerve fiber density (P = 0.004), nerve branch density (P = 0.004), total nerve branch density (P = 0.04), and nerve fiber length (P = 0.001), and greater nerve fiber width (P = 0.04) were observed in patients with type 1 diabetes compared to control subjects. Significantly lower epithelial (P < 0.001) and endothelial (P = 0.02) cell densities, nerve branch density (P = 0.02), and nerve fiber length (P = 0.04), and significantly higher keratocyte cell density (P = 0.02) were found in patients with type 1 diabetes without retinopathy compared to control subjects. Corneal confocal microscopy identifies corneal cellular and small nerve fiber pathology in young patients with type 1 diabetes without retinopathy, which increases in severity in those with retinopathy. Corneal confocal microscopy appears to have considerable use as an imaging biomarker for early subclinical pathology in young patients with type 1 diabetes mellitus.

  2. Growth of cultured corneal endothelial cells onto a vitreous carbon matrix.

    PubMed

    Wickham, M G; Cleveland, P H; Binder, P S; Akers, P H

    1983-01-01

    Fourth passage cells of a rabbit corneal endothelial line were grown for 1 week in flasks containing pieces of a reticulated vitreous carbon matrix. The rate of cell growth in flasks containing the matrix was consistent with that in control flasks. Small fragments of the vitreous carbon material lying on the flask floor were covered by the monolayers as the cells grew to confluency. Vertical growth of cells onto larger pieces of the matrix proceeded in a staged fashion with maximum cell density on pieces of the matrix closest to the floor of the flask. As defined by scanning electron microscopy, cell growth occurred to a level at least 600 microns above the floor of the flask and the confluent monolayer. This novel culture procedure should be a model situation for study of many different aspects of the in vitro capabilities of corneal endothelial cells.

  3. Proteomic analysis of corneal endothelial cell-descemet membrane tissues reveals influence of insulin dependence and disease severity in type 2 diabetes mellitus.

    PubMed

    Skeie, Jessica M; Aldrich, Benjamin T; Goldstein, Andrew S; Schmidt, Gregory A; Reed, Cynthia R; Greiner, Mark A

    2018-01-01

    The objective of this study was to characterize the proteome of the corneal endothelial cell layer and its basement membrane (Descemet membrane) in humans with various severities of type II diabetes mellitus compared to controls, and identify differentially expressed proteins across a range of diabetic disease severities that may influence corneal endothelial cell health. Endothelium-Descemet membrane complex tissues were peeled from transplant suitable donor corneas. Protein fractions were isolated from each sample and subjected to multidimensional liquid chromatography and tandem mass spectrometry. Peptide spectra were matched to the human proteome, assigned gene ontology, and grouped into protein signaling pathways unique to each of the disease states. We identified an average of 12,472 unique proteins in each of the endothelium-Descemet membrane complex tissue samples. There were 2,409 differentially expressed protein isoforms that included previously known risk factors for type II diabetes mellitus related to metabolic processes, oxidative stress, and inflammation. Gene ontology analysis demonstrated that diabetes progression has many protein footprints related to metabolic processes, binding, and catalysis. The most represented pathways involved in diabetes progression included mitochondrial dysfunction, cell-cell junction structure, and protein synthesis regulation. This proteomic dataset identifies novel corneal endothelial cell and Descemet membrane protein expression in various stages of diabetic disease. These findings give insight into the mechanisms involved in diabetes progression relevant to the corneal endothelium and its basement membrane, prioritize new pathways for therapeutic targeting, and provide insight into potential biomarkers for determining the health of this tissue.

  4. Comparison of the effects of intraocular irrigating solutions on the corneal endothelium in intraocular lens implantation.

    PubMed Central

    Matsuda, M; Kinoshita, S; Ohashi, Y; Shimomura, Y; Ohguro, N; Okamoto, H; Omoto, T; Hosotani, H; Yoshida, H

    1991-01-01

    We conducted a randomised prospective controlled study to determine the effects of a glucose glutathione bicarbonate solution (BSS Plus) and a citrate acetate bicarbonate solution (S-MA2) on the corneal endothelium in patients undergoing extracapsular cataract extraction with posterior chamber lens implantation. One eye of each patient was randomly assigned to receive BSS Plus, and the other eye to receive S-MA2. BSS Plus caused significantly less corneal swelling on the first postoperative day than did S-MA2. There was no difference between the two solutions in their effect on corneal thickness one week and one month postoperatively. Computer assisted morphometric analysis of wide-field specular microscopic photographs demonstrated minimal changes in endothelial morphological characteristics in the eyes irrigated with BSS Plus. By comparison S-MA2, caused a significant loss of endothelial cells and a marked reduction in the figure coefficient. These results indicated that BSS Plus has a clinical advantage over S-MA2 with respect to the corneal endothelium. PMID:1873266

  5. Management of corneal decompensation 4 decades after Sputnik intraocular lens implantation.

    PubMed

    Hirji, Nashila; Nanavaty, Mayank A

    2015-01-01

    We report an unusual case of corneal decompensation occurring four decades after complicated cataract extraction with implantation of a Sputnik intraocular lens (IOL) and highlight the clinical and practical issues faced in managing corneal decompensation with a Sputnik IOL. A 72-year-old woman presented with deterioration of the vision in her left eye, four decades after intracapsular cataract extraction with Sputnik IOL implantation. Ocular examination revealed diffuse corneal edema and thickened vitreous strands in the anterior chamber. Her best-corrected visual acuity (BCVA) worsened to 6/60 within 3 months. Anterior vitrectomy and inferior iridectomy combined with Desçemet-stripping automated endothelial keratoplasty was performed. The procedure was successful, with the patient achieving best-corrected visual acuity of 6/6 at 8 months postoperatively. Corneal decompensation after Sputnik IOL implantation can occur four decades later. When the historical preoperative visual acuity is good in such cases, careful anterior vitrectomy with Desçemet-stripping automated endothelial keratoplasty provides good visual rehabilitation.

  6. An easy and inexpensive method for quantitative analysis of endothelial damage by using vital dye staining and Adobe Photoshop software.

    PubMed

    Saad, Hisham A; Terry, Mark A; Shamie, Neda; Chen, Edwin S; Friend, Daniel F; Holiman, Jeffrey D; Stoeger, Christopher

    2008-08-01

    We developed a simple, practical, and inexpensive technique to analyze areas of endothelial cell loss and/or damage over the entire corneal area after vital dye staining by using a readily available, off-the-shelf, consumer software program, Adobe Photoshop. The purpose of this article is to convey a method of quantifying areas of cell loss and/or damage. Descemet-stripping automated endothelial keratoplasty corneal transplant surgery was performed by using 5 precut corneas on a human cadaver eye. Corneas were removed and stained with trypan blue and alizarin red S and subsequently photographed. Quantitative assessment of endothelial damage was performed by using Adobe Photoshop 7.0 software. The average difference for cell area damage for analyses performed by 1 observer twice was 1.41%. For analyses performed by 2 observers, the average difference was 1.71%. Three masked observers were 100% successful in matching the randomized stained corneas to their randomized processed Adobe images. Vital dye staining of corneal endothelial cells can be combined with Adobe Photoshop software to yield a quantitative assessment of areas of acute endothelial cell loss and/or damage. This described technique holds promise for a more consistent and accurate method to evaluate the surgical trauma to the endothelial cell layer in laboratory models. This method of quantitative analysis can probably be generalized to any area of research that involves areas that are differentiated by color or contrast.

  7. Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification

    PubMed Central

    Módis, László Jr.; Szalai, Eszter; Flaskó, Zsuzsa; Németh, Gábor

    2016-01-01

    Purpose. To study the endothelial cell morphology and corneal thickness changes after phacoemulsification by using the OZil torsional and longitudinal ultrasound techniques (Infiniti Vision System, Alcon Laboratories). Setting. Department of Ophthalmology, Clinical Center, University of Debrecen, Debrecen, Hungary. Methods. 52 patients with cataract were randomly assigned to longitudinal ultrasound and torsional mode group. All surgeries were performed through a 2.2 mm clear corneal incision, the method employed being divide and conquer. The endothelial morphometry such as cell density (ECD), mean cell area, coefficient of variation of cell area, and central corneal thickness were examined with specular microscopy (EM-1000, Tomey) preoperatively and 4, 8 weeks postoperatively. Results. ECD values decreased significantly in both surgical groups (P < .001, repeated- mesures ANOVA), the postoperative endothelial cell loss was higher in the longitudinal ultrasound mode group (3.5% and 6.5%, at 4 and 8 weeks after surgery) than in the torsional group (3.3% and 5.5%, at 4 and 8 weeks after surgery), the difference not being significant between the two groups (P = .164 and P = .479, at 4 and 8 weeks after surgery, Mann-Whitney test). There was no statistically significant difference in any of the assessed parameters between the two surgical groups (P > .05). No significant correlation was found between the endothelial cell loss and the nucleus density. Conclusions. Both phacoemulsification techniques were safe and effective. The torsional handpiece performs oscillatory movements and delivers less energy into the eye than the longitudinal ultrasound technique, therefore providing more favorable energy and thermal safety profile. PMID:29450332

  8. Accelerated versus conventional corneal collagen cross-linking in patients with keratoconus: an intrapatient comparative study.

    PubMed

    Sadoughi, Mohammad Mehdi; Einollahi, Bahram; Baradaran-Rafii, Alireza; Roshandel, Danial; Hasani, Hamidreza; Nazeri, Mehrdad

    2018-02-01

    To compare the outcomes of the conventional and accelerated corneal collagen cross-linking (CXL) in patients with bilateral progressive keratoconus (KC). Fifteen consecutive patients with bilateral progressive KC were enrolled. In each patient, the fellow eyes were randomly assigned to the conventional CXL (3 mW/cm 2 for 30 min) or accelerated CXL (ACXL) (9 mW/cm 2 for 10 min) groups. Manifest refraction; uncorrected and corrected distant visual acuity; maximum and mean keratometry; corneal hysteresis and corneal resistance factor; endothelial cell density and morphology; central corneal thickness; and wavefront aberrations were measured before and 12 months after the CXL. Manifest refraction spherical equivalent and refractive cylinder improved significantly only in conventional group. Uncorrected and corrected distant visual acuity did not change significantly in either group. Also there was no significant change in the maximum and mean keratometry after 12 months. There was significant decrease in central corneal thickness in both groups which was more prominent in conventional group. Endothelial cell density reduced only in the conventional group which was not statistically significant (P = 0.147). CH, CRF, and wavefront aberrations did not change significantly in either group. We did not observe any significant difference in the changes of the variables between the two groups. Accelerated CXL with 9 mW/cm 2 irradiation for 10 min had similar refractive, visual, keratometric, and aberrometric results and less adverse effects on the corneal thickness and endothelial cells as compared with the conventional method after 12 months follow-up. However, randomized clinical trials with longer follow-ups and larger sample sizes are needed.

  9. Corneal Equilibrium Flux as a Function of Corneal Surface Oxygen Tension.

    PubMed

    Compañ, Vicente; Aguilella-Arzo, Marcel; Weissman, Barry A

    2017-06-01

    Oxygen is essential for aerobic mammalian cell physiology. Oxygen tension (PO2) should reach a minimum at some position within the corneal stroma, and oxygen flux should be zero, by definition, at this point as well. We found the locations and magnitudes of this "corneal equilibrium flux" (xmin) and explored its physiological implications. We used an application of the Monod kinetic model to calculate xmin for normal human cornea as anterior surface PO2 changes from 155 to 20 mmHg. We find that xmin deepens, broadens, and advances from 1.25 μm above the endothelial-aqueous humor surface toward the epithelium (reaching a position 320 μm above the endothelial-aqueous humor surface) as anterior corneal surface PO2 decreases from 155 to 20 mmHg. Our model supports an anterior corneal oxygen flux of 9 μL O2 · cm · h and an epithelial oxygen consumption of approximately 4 μL O2 · cm · h. Only at the highest anterior corneal PO2 does our model predict that oxygen diffuses all the way through the cornea to perhaps reach the anterior chamber. Of most interest, corneal oxygen consumption should be supported down to a corneal surface PO2 of 60 to 80 mmHg but declines below this range. We conclude that the critical oxygen tension for hypoxia induced corneal swelling is more likely this range rather than a fixed value.

  10. The South Asian cataract management study: complications, vision outcomes, and corneal endothelial cell loss in a randomized multicenter clinical trial comparing intracapsular cataract extraction with and without anterior chamber intraocular lens implantation.

    PubMed

    Snellingen, T; Shrestha, J K; Huq, F; Husain, R; Koirala, S; Rao, G N; Pokhrel, R P; Kolstad, A; Upadhyay, M P; Apple, D J; Arnesen, E; Cheng, H; Olsen, E G; Vogel, M

    2000-02-01

    To determine clinical outcomes of primary intracapsular cataract surgery with and without implantation of anterior chamber lenses. A multicenter randomized clinical trial. One thousand two hundred twenty-nine male and female patients 40-75 years of age with senile cataract. Study patients were recruited from screening eye camps and outpatient clinics. Randomization to the two treatment groups was performed after screening for predetermined inclusion and exclusion criteria. Demographics, visual acuity, intraocular pressures, and corneal endothelial cell data were recorded before surgery and at 6 weeks, 12 months, and 24 months after surgery. Monitoring of the study was secured by a standardized image documentation procedure on all patients using the IMAGEnet digital imaging system. Analysis of corneal endothelial cell images was performed with the Cell Soft software (Topcon Corporation, Japan). Visual acuity and central corneal endothelial cell loss. The patients were randomized to intraocular lens (IOL; n = 616) and no IOL (n = 613) implantation. Surgical complications were reported in 177 (14.4%) patients (IOL = 14.8%; no IOL = 14.0%). The most frequent complication observed was vitreous loss which occurred in 10.3% of eyes (IOL = 11.2%; no IOL = 9.5%). At the final examination (2 years after surgery), 88% of the operated eyes had a best corrected vision of 6/18 or better (IOL = 88.8%; no IOL = 86.6%). Analysis of corneal endothelial cell data showed a small but significantly greater cell loss 6 weeks after surgery in eyes with IOL compared with those without IOL, but no overall difference was found between the treatment groups in the long term follow-up. The findings indicate that there is a rationale for the use of anterior chamber intraocular lenses in primary intracapsular cataract surgery.

  11. Electrospun nanofibrous SF/P(LLA-CL) membrane: a potential substratum for endothelial keratoplasty.

    PubMed

    Chen, Junzhao; Yan, Chenxi; Zhu, Mengyu; Yao, Qinke; Shao, Chunyi; Lu, Wenjuan; Wang, Jing; Mo, Xiumei; Gu, Ping; Fu, Yao; Fan, Xianqun

    2015-01-01

    Cornea transplant technology has progressed markedly in recent decades, allowing surgeons to replace diseased corneal endothelium by a thin lamellar structure. A thin, transparent, biocompatible, tissue-engineered substratum with corneal endothelial cells for endothelial keratoplasty is currently of interest. Electrospinning a nanofibrous structure can simulate the extracellular matrix and have beneficial effects for cell culture. Silk fibroin (SF) has good biocompatibility but poor mechanical properties, while poly(L-lactic acid-co-ε-caprolactone) (P(LLA-CL)) has good mechanical properties but poor biocompatibility. Blending SF with P(LLA-CL) can maintain the advantages of both these materials and overcome their disadvantages. Blended electrospun nanofibrous membranes may be suitable for regeneration of the corneal endothelium. The aim of this study was to produce a tissue-engineered construct suitable for endothelial keratoplasty. Five scaffolds containing different SF:P(LLA-CL) blended ratios (100:0, 75:25, 50:50, 25:75, 0:100) were manufactured. A human corneal endothelial (B4G12) cell line was cultured on the membranes. Light transmission, speed of cell adherence, cell viability (live-dead test), cell proliferation (Ki-67, BrdU staining), and cell monolayer formation were detected on membranes with the different blended ratios, and expression of some functional genes was also detected by real-time polymerase chain reaction. Different blended ratios of scaffolds had different light transmittance properties. The 25:75 blended ratio membrane had the best transmittance among these scaffolds. All electrospun nanofibrous membranes showed improved speed of cell adherence when compared with the control group, especially when the P(LLA-CL) ratio increased. The 25:75 blended ratio membranes also had the highest cell proliferation. B4G12 cells could form a monolayer on all scaffolds, and most functional genes were also stably expressed on all scaffolds. Only two genes showed changes in expression. All blended ratios of SF:P(LLA-CL) scaffolds were evaluated and showed good biocompatibility for cell adherence and monolayer formation. Among them, the 25:75 blended ratio SF:P(LLA-CL) scaffold had the best transmittance and the highest cell proliferation. These attributes further the potential application of the SF:P(LLA-CL) scaffold for corneal endothelial transplantation.

  12. Effect of different culture media and deswelling agents on survival of human corneal endothelial and epithelial cells in vitro.

    PubMed

    Valtink, Monika; Donath, Patricia; Engelmann, Katrin; Knels, Lilla

    2016-02-01

    To examine the effects of media and deswelling agents on human corneal endothelial and epithelial cell viability using a previously developed screening system. The human corneal endothelial cell line HCEC-12 and the human corneal epithelial cell line HCE-T were cultured in four different corneal organ culture media (serum-supplemented: MEM +2 % FCS, CorneaMax®/CorneaJet®, serum-free: Human Endothelial-SFM, Stemalpha-2 and -3) with and without 6 % dextran T500 or 7 % HES 130/0.4. Standard growth media F99HCEC and DMEM/F12HCE-T served as controls. In additional controls, the stress inducers staurosporine or hydrogen peroxide were added. After 5 days in the test media, cell viability was assessed by flow cytometrically quantifying apoptotic and necrotic cells (sub-G1 DNA content, vital staining with YO-PRO-1® and propidium iodide) and intracellular reactive oxygen species (ROS). The MEM-based media were unable to support HCEC-12 and HCE-T survival under stress conditions, resulting in significantly increased numbers of apoptotic and necrotic cells. HCEC-12 survival was markedly improved in SFM-based media even under staurosporine or hydrogen peroxide. Likewise, HCE-T survival was improved in SFM with or without dextran. The media CorneaMax®, CorneaJet®, and CorneaMax® with HES supported HCEC-12 survival better than MEM-based media, but less well than SFM-based media. HCE-T viability was also supported by CorneaJet®, but not by CorneaMax® with or without HES. Stemalpha-based media were not suitable for maintaining viability of HCEC-12 or HCE-T in the applied cell culture system. The use of serum-supplemented MEM-based media for corneal organ culture should be discontinued in favour of serum-free media like SFM.

  13. Femtosecond laser correction of presbyopia (INTRACOR) in emmetropes using a modified pattern.

    PubMed

    Thomas, Bettina C; Fitting, Anna; Auffarth, Gerd U; Holzer, Mike P

    2012-12-01

    To evaluate functional results and corneal changes after femtosecond laser correction of presbyopia (INTRACOR, Technolas Perfect Vision GmbH) in emmetropes using a modified treatment pattern over a 12-month period. Twenty eyes from 20 emmetropic patients were treated with a modified intrastromal INTRACOR pattern consisting of 5 central rings and 8 radial cuts in a prospective, nonrandomized, uncontrolled, open, single-center, clinical study. Refraction, visual acuity, endothelial cell density, corneal pachymetry, total corneal power, and stray light were evaluated preoperatively and 1 (except endothelial cell density and stray light), 3, 6, and 12 months postoperatively. Patients filled out a subjective questionnaire at 12 months postoperatively. Comparison of preoperative versus 12-month postoperative median values revealed a significant improvement in uncorrected near visual acuity (UNVA) from 0.60 (20/80) to 0.10 logMAR (20/25) (P<.0001) and a significant decrease in corrected distance visual acuity (CDVA) from -0.10 (20/16) to 0.00 logMAR (20/20), which equals a median loss of one line (P=.0005). Fifteen percent of patients lost two lines of CDVA in the treated eye. Subjective spherical equivalent refraction remained unchanged at 0.00 diopters (D) (P=.194). After INTRACOR treatment, significant corneal steepening of 1.40 D and midperipheral flattening of 0.50 D occurred (both P<.0001). Corneal pachymetry at the thinnest point and endothelial cell density did not change significantly (P=.829 and P=.058, respectively). After 12 months, the modified INTRACOR pattern improved UNVA in emmetropic patients without inducing a myopic shift or significant changes in endothelial cell density or pachymetry. Copyright 2012, SLACK Incorporated.

  14. Revisited microanatomy of the corneal endothelial periphery: new evidence for continuous centripetal migration of endothelial cells in humans.

    PubMed

    He, Zhiguo; Campolmi, Nelly; Gain, Philippe; Ha Thi, Binh Minh; Dumollard, Jean-Marc; Duband, Sébastien; Peoc'h, Michel; Piselli, Simone; Garraud, Olivier; Thuret, Gilles

    2012-11-01

    The control of corneal transparency depends on the integrity of its endothelial monolayer, which is considered nonregenerative in adult humans. In pathological situations, endothelial cell (EC) loss, not offset by mitosis, can lead to irreversible corneal edema and blindness. However, the hypothesis of a slow, clinically insufficient regeneration starting from the corneal periphery remains debatable. The authors have re-evaluated the microanatomy of the endothelium in order to identify structures likely to support this homeostasis model. Whole endothelia of 88 human corneas (not stored, and stored in organ culture) with mean donor age of 80 ± 12 years were analyzed using an original flat-mounting technique. In 61% of corneas, cells located at the extreme periphery (last 200 μm of the endothelium) were organized in small clusters with two to three cell layers around Hassall-Henle bodies. In 68% of corneas, peripheral ECs formed centripetal rows 830 ± 295 μm long, with Descemet membrane furrows visible by scanning electron microscopy. EC density was significantly higher in zones with cell rows. When immunostained, ECs in the extreme periphery exhibited lesser differentiation (ZO-1, Actin, Na/K ATPase, CoxIV) than ECs in the center of the cornea but preferentially expressed stem cell markers (Nestin, Telomerase, and occasionally breast cancer resistance protein) and, in rare cases, the proliferation marker Ki67. Stored corneas had fewer cell clusters but more Ki67-positive ECs. We identified a novel anatomic organization in the periphery of the human corneal endothelium, suggesting a continuous slow centripetal migration, throughout life, of ECs from specific niches. Copyright © 2012 AlphaMed Press.

  15. Inhibitory effects of polysaccharide extract from Spirulina platensis on corneal neovascularization

    PubMed Central

    Yang, Lingling; Wang, Yao; Zhou, Qingjun; Chen, Peng; Wang, Yiqiang; Wang, Ye; Liu, Ting

    2009-01-01

    Purpose To assess the effects of polysaccharide extract from Spirulina platensis (PSP) on corneal neovascularization (CNV) in vivo and in vitro. Methods PSP was extracted from dry powder of Spirulina platensis. Its anti-angiogenic activity was evaluated in the mouse corneal alkali burn model after topical administration of PSP four times daily for up to seven days. Corneal samples were processed for histochemical, immunohistochemical, and gene expression analyses. The effects of PSP on proliferation, migration, tube formation, and serine threonine kinase (AKT) and extracellular regulated kinase1/2 (ERK1/2) signaling levels in vascular endothelial cells were determined using 3-(4,5)-dimethylthiahiazo (-z-y1)-3, 5-di-phenytetrazoliumromide (MTT) and carboxyfluorescein succinimidyl ester (CFSE) labeling assays, wound healing assay, Matrigel tube formation assay, and western blot. Results Topical application of PSP significantly inhibited CNV caused by alkali burn. Corneas treated with PSP showed reduced levels of platelet endothelial cell adhesion molecule (CD31) and stromal cell-derived factor 1 (SDF1) proteins, reduced levels of vascular endothelial growth factor (VEGF), matrix metalloproteinase-2 (MMP2), matrix metalloproteinase-9 (MMP9), SDF1, and tumor necrosis factor-alpha (TNF-α) mRNAs, and an increased level of pigment epithelium-derived factor (PEDF) mRNA. These are parameters that have all been related to CNV and/or inflammation. In human vascular endothelial cells, PSP significantly inhibited proliferation, migration, and tube formation in a dose-dependent manner. Furthermore, PSP also decreased the levels of activated AKT and ERK 1/2. Conclusions These data suggest that polysaccharide extract from Spirulina platensis is a potent inhibitor of CNV and that it may be of benefit in the therapy of corneal diseases involving neovascularization and inflammation. PMID:19784394

  16. A case of Weill-Marchesani syndrome with inversion of chromosome 15.

    PubMed

    Chung, Jae Lim; Kim, Sun Woong; Kim, Ji Hyun; Kim, Tae-Im; Lee, Hyung Keun; Kim, Eung Kweon

    2007-12-01

    To present a case of Weill-Marchesani syndrome with corneal endothelial dysfunction due to anterior dislocation of a spherophakic lens and corneolenticular contact. A 17-year-old woman presented with high myopia and progressive visual disturbance. She was of short stature and had brachydactyly. Her initial Snellen best corrected visual acuity (BCVA) was 20/50 (-sph 20.50 -cyl 3.00 Ax 180) in her right eye and 20/40 (-sph 16.00 -cyl 6.00 Ax 30) in her left eye. Slit lamp examination revealed a dislocated spherophakic lens touching corenal endothelium. A microspherophakic lens, hypoplastic ciliary body, and elongated zonules were confirmed on rotating Scheimpflug camera (Pentacam) and on ultrasound biomicroscopy. Specular microscopy showed corneal endothealial dysfunction. Systemic evaluation was performed, and chromosomal study showed 46, XX, inv (15) (q13qter). The patient was diagnosed with Weill-Marchesani syndrome. Due to impending corneal decompensation, phacoemulsification and suture fixation of the intraocular lens were performed. The operation and postoperative course were uneventful. Three months postoperatively, the visual acuity was 20/30 (OD) and 20/40 (OS) without correction, and BCVA was 20/20 (+sph 0.50 -cyl 2.00 Ax 160 : OD) and 20/25 (+sph 1.50 -cyl 3.00 Ax 30 : OS). During the follow-up period, increased corneal endothelial counts, hexagonality, and decreased corneal thickness were achieved. In Weill-Marchesani syndrome with a chromosomal anomaly, a dislocated spherophakic lens may cause severe corneal endothelial dysfunction due to corneolenticular contact, and prompt lensectomy is important to prevent such complications.

  17. Characterisation of the porcine eyeball as an in-vitro model for dry eye.

    PubMed

    Menduni, Francesco; Davies, Leon N; Madrid-Costa, D; Fratini, Antonio; Wolffsohn, James S

    2018-02-01

    To characterise the anatomical parameters of the porcine eye for potentially using it as a laboratory model of dry eye. Anterior chamber depth and angle, corneal curvature, shortest and longest diameter, endothelial cell density, and pachymetry were measured in sixty freshly enucleated porcine eyeballs. Corneal steepest meridian was 7.85±0.32mm, corneal flattest meridian was 8.28±0.32mm, shortest corneal diameter was 12.69±0.58mm, longest corneal diameter was 14.88±0.66mm and central corneal ultrasonic pachymetry was 1009±1μm. Anterior chamber angle was 28.83±4.16°, anterior chamber depth was 1.77±0.27mm, and central corneal thickness measured using OCT was 1248±144μm. Corneal endothelial cell density was 3250±172 cells/mm 2 . Combining different clinical techniques produced a pool of reproducible data on the porcine eye anatomy, which can be used by researchers to assess the viability of using the porcine eye as an in-vitro/ex-vivo model for dry eye. Due to the similar morphology with the human eye, porcine eyeballs may represent a useful and cost effective model to individually study important key factors in the development of dry eye, such as environmental and mechanical stresses. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Changes in corneal topography and biomechanical properties after collagen cross linking for keratoconus: 1-year results.

    PubMed

    Sedaghat, Mohammadreza; Bagheri, Mansooreh; Ghavami, Shahri; Bamdad, Shahram

    2015-01-01

    To evaluate changes in corneal topography and biomechanical properties after collagen cross-linking (CXL) for progressive keratoconus. Collagen cross-linking was performed on 97 eyes. We assessed uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA). Corneal topography indices were evaluated using placido disc topography, scanning slit anterior topography (Orbscan II), and rotating Scheimpflug topography (Pentacam). Specular microscopy and corneal biomechanics were evaluated. A 1-year-follow-up results revealed that UCVA improved from 0.31 to 0.45 and BCVA changed from 0.78 to 0.84 (P < 0.001). The mean of average keratometry value decreased from 49.62 to 47.95 D (P < 0.001). Astigmatism decreased from 4.84 to 4.24 D (P < 0.001). Apex corneal thickness decreased from 458.11 to 444.46 μm. Corneal volume decreased from 56.66 to 55.97 mm(3) (P < 0.001). Posterior best fit sphere increased from 55.50 to 46.03 mm (P = 0.025). Posterior elevation increased from 99.2 to 112.22 μm (P < 0.001). Average progressive index increased from 2.26 to 2.56 (P < 0.001). A nonsignificant decrease was observed in mean endothelial count from 2996 to 2928 cell/mm(2) (P = 0.190). Endothelial coefficient of variation (CV) increased nonsignificantly from 18.26 to 20.29 (P = 0.112). Corneal hysteresis changed from 8.18 to 8.36 (P = 0.552) and corneal resistance factor increased from 6.98 to 7.21 (P = 0.202), so these changes were not significant. Visual acuity and K values improved after CXL. In spite of the nonsignificant increase in endothelial cell count and increase in the CV, CLX seems to be a safe treatment for keratoconus. Further studies with larger sample sizes and longer follow-up periods are recommended.

  19. The histopathological effect of intracameral ropivacaine in different concentrations on corneal endothelium.

    PubMed

    Caça, Ihsan; Kavak, Vatan; Unlü, Kaan; Ari, Seyhmus; Nergis, Yusuf; Take, Gülnür

    2006-01-01

    We evaluated the histopathological changes occurring in corneal endothelium after intracameral injection ropivacaine into rats. Intracamerally administered ropivacaine in 1, 0.5, and 0.1% concentrations resulted in impairment of hexagonal structure of corneal endothelial cells and intercellular junctions, destruction of microvilli on the cell surface, roughness of cell borders, picnotic nucleus, diffuse vacuolization, and crystalysis in mitochondria.

  20. Tissue quality of eye-bank-prepared precut corneas for Descemet's stripping automated endothelial keratoplasty.

    PubMed

    Nelson, Brian A; Ritenour, Rusty J

    2014-02-01

    To evaluate endothelial cell density (ECD) of eye-bank-prepared tissue for use in Descemet's stripping automated endothelial keratoplasty (DSAEK). Prospective case series of consecutive corneal tissue prepared for DSAEK surgery. Sixty-seven sequential corneal-scleral tissue specimens representing 48 human donors processed for use in DSAEK surgery by the Regional Tissue Bank (Halifax, Nova Scotia). Corneal-scleral donor tissue was obtained by in situ recovery. ECD was recorded using the EB-3000 XYZ (HAI Laboratories Inc, Lexington, MA) specular microscope within 24 hours of preservation. Before the tissue was dissected, the corneal thickness was measured using the DGH-550 PACHETTE 2 (DGH Technology, Exton, PA) ultrasound pachymeter. The dissection was performed using a 300-μm Moria ALTK model microkeratome (Moria Inc). The posterior bed thickness was measured, and the anterior flap was replaced. Endothelial cell count density was obtained after re-preservation. Complete measurements were obtained for 42 of 67 corneas. In 25 corneas it was not possible to obtain a postdissection ECD measurement. The mean ECD before dissection was 2806 ± 317 cells/mm(2). The mean ECD after dissection was 2772 ± 318 cells/mm(2). There was an average loss of 34 cells/mm(2) (95% CI -110 to 40 cells/mm(2), p = 0.3). This case series confirms that ECD is preserved when DSAEK tissue is prepared in advance of surgery by trained eye-bank technicians in a low-volume Canadian eye bank. It was difficult to obtain clear images of the endothelial cell layer postdissection, possibly because of tissue swelling or distortion. Sixty-six of 67 corneas included in the study were used for surgery. © 2013 Canadian Ophthalmological Society Published by Canadian Ophthalmological Society All rights reserved.

  1. Alcohol-assisted debridement in PRK with intraoperative mitomycin C.

    PubMed

    Nassiri, Nader; Sheibani, Kourosh; Safi, Sare; Haghnegahdar, Maryam; Nassiri, Saman; Panahi, Nekoo; Mehravaran, Shiva; Nassiri, Nariman

    2014-09-01

    To compare corneal stromal and endothelial cells after photorefractive keratectomy with intraoperative mitomycin C in alcohol-assisted versus mechanical epithelial debridement using confocal microscopy. This prospective randomized comparative study was performed on 88 eyes (44 patients) with myopia up to -6.00 diopters. The right eye of each patient was randomly assigned to either mechanical or alcohol-assisted groups, and the left eye was assigned to the alternate group. Confocal microscopy was performed preoperatively and at 3 months postoperatively. The main outcome measures were epithelial thickness; number of keratocytes in the anterior, mid-, and posterior stroma; and characteristics of the central corneal endothelial cells in terms of density, mean cell area, and polymegathism and hexagonality. Three months after surgery, no statistically significant difference was noted between the study groups in terms of epithelial thickness. We also found no statistically significant difference in central corneal endothelial cells regarding cell density, mean cell area, hexagonality, or polymegathism. Compared with baseline values, the density of mid- and posterior stromal keratocytes showed no significant change in either group, whereas it decreased significantly in the anterior stroma in both groups 3 months after surgery. We found that the adverse effects of photorefractive keratectomy with mitomycin C on central corneal endothelial cells were comparable between the mechanical and alcohol-assisted epithelial debridement groups and the significant decrease in postoperative keratocyte density in anterior stroma was comparable between the two groups. The choice of their application could be left to the discretion of the ophthalmologist.

  2. Effect of Fibrin Glue on the Biomechanical Properties of Human Descemet's Membrane

    PubMed Central

    Chaurasia, Shyam S.; Champakalakshmi, Ravi; Li, Ang; Poh, Rebekah; Tan, Xiao Wei; Lakshminarayanan, Rajamani; Lim, Chwee T.; Tan, Donald T.; Mehta, Jodhbir S.

    2012-01-01

    Background Corneal transplantation has rapidly evolved from full-thickness penetrating keratoplasty (PK) to selective tissue corneal transplantation, where only the diseased portions of the patient's corneal tissue are replaced with healthy donor tissue. Descemet's membrane endothelial keratoplasty (DMEK) performed in patients with corneal endothelial dysfunction is one such example where only a single layer of endothelial cells with its basement membrane (10–15 µm in thickness), Descemet's membrane (DM) is replaced. It is challenging to replace this membrane due to its intrinsic property to roll in an aqueous environment. The main objective of this study was to determine the effects of fibrin glue (FG) on the biomechanical properties of DM using atomic force microscopy (AFM) and relates these properties to membrane folding propensity. Methodology/Principal Findings Fibrin glue was sprayed using the EasySpray applicator system, and the biomechanical properties of human DM were determined by AFM. We studied the changes in the “rolling up” tendency of DM by examining the changes in the elasticity and flexural rigidity after the application of FG. Surface topography was assessed using scanning electron microscopy (SEM) and AFM imaging. Treatment with FG not only stabilized and stiffened DM but also led to a significant increase in hysteresis of the glue-treated membrane. In addition, flexural or bending rigidity values also increased in FG-treated membranes. Conclusions/Significance Our results suggest that fibrin glue provides rigidity to the DM/endothelial cell complex that may aid in subsequent manipulation by maintaining tissue integrity. PMID:22662156

  3. Corneal endothelial cell density and morphology in patients with acromegaly.

    PubMed

    Hatipoglu, Esra; Arici, Ceyhun; Arslan, Osman Sevki; Dikkaya, Funda; Sultan, Pinar; Kadioglu, Pinar; Gundogdu, Sadi

    2014-12-01

    Acromegaly has various impacts on many organs. The ophthalmologic effects of acromegaly have not yet been investigated in detail. The aim of the current study was to evaluate qualitative and quantitative changes in corneal endothelial cells and central corneal thickness (CCT) of the patients with acromegaly. In this prospective, cross-sectional study, 128 eyes of 64 patients with acromegaly (female/male=40/24) and 208 eyes of 104 age and gender-matched healthy volunteers (female/male=69/35) were included. Endothelial cell density (ECD), cellular area (CA), coefficient of variation (CV) in cell size, percentage of hexagonal cells, and CCT were measured in patients with acromegaly and in healthy volunteers using the noncontact specular microscopy (SP-3000P: Topcon Corporation, Tokyo, Japan). ECD and CA were lower in cases with acromegaly than in controls (ECD in acromegaly: 2615.65 cell/mm(2) and in controls: 2700.35 cell/mm(2); p=0.002. CA in acromegaly: 382.30μm(2) and in controls: 400.30μm(2); p=0.02). In the entire group with acromegaly, the time elapsed since diagnosis was positively correlated with CA and was negatively correlated with ECD (r=+0.39, p=0.001 and r=-0.42, p=0.001). The endothelial layer of the cornea may be under risk of impairment with prolonged disease duration in acromegaly. Consistency of the corneal endothelium should be also sought during long-term follow-up of the cases with acromegaly. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Pseudophakodonesis and corneal endothelial contact: direct observations by high-speed cinematography.

    PubMed

    Jacobs, P M; Cheng, H; Price, N C

    1983-10-01

    High-speed cinematography was used to observe the movement of Federov type I lens implants within the anterior chamber. Our measurements suggest that in most patients contact between the lens implant and corneal endothelium does not occur.

  5. Dental stem cells: a future asset of ocular cell therapy.

    PubMed

    Yam, Gary Hin-Fai; Peh, Gary Swee-Lim; Singhal, Shweta; Goh, Bee-Tin; Mehta, Jodhbir S

    2015-11-10

    Regenerative medicine using patient's own stem cells (SCs) to repair dysfunctional tissues is an attractive approach to complement surgical and pharmacological treatments for aging and degenerative disorders. Recently, dental SCs have drawn much attention owing to their accessibility, plasticity and applicability for regenerative use not only for dental, but also other body tissues. In ophthalmology, there has been increasing interest to differentiate dental pulp SC and periodontal ligament SC (PDLSC) towards ocular lineage. Both can commit to retinal fate expressing eye field transcription factors and generate rhodopsin-positive photoreceptor-like cells. This proposes a novel therapeutic alternative for retinal degeneration diseases. Moreover, as PDLSC shares similar cranial neural crest origin and proteoglycan secretion with corneal stromal keratoctyes and corneal endothelial cells, this offers the possibility of differentiating PDLSC to these corneal cell types. The advance could lead to a shift in the medical management of corneal opacities and endothelial disorders from highly invasive corneal transplantation using limited donor tissue to cell therapy utilizing autologous cells. This article provides an overview of dental SC research and the perspective of utilizing dental SCs for ocular regenerative medicine.

  6. Panoramic view of human corneal endothelial cell layer observed by a prototype slit-scanning wide-field contact specular microscope.

    PubMed

    Tanaka, Hiroshi; Okumura, Naoki; Koizumi, Noriko; Sotozono, Chie; Sumii, Yasuhiro; Kinoshita, Shigeru

    2017-05-01

    To observe the most peripheral region of the corneal endothelial cell (CEC) layer as long as optically recordable by use of a prototype slit-scanning wide-field contact specular microscope and produce a panoramic image to evaluate the variation of CEC density with ageing. Observational case series study. This study involved 15 eyes of 15 normal healthy subjects divided into three groups according to age: A (20-40 years), B (41-60 years) and C (>60 years). The corneal endothelial layer of each eye was recorded in a horizontal direction, from nasal to temporal, with a slit-scanning wide-field contact specular microscope (Konan) and endothelial cell density (ECD) in three specific regions (central, mid-peripheral, and peripheral) was automatically calculated via built-in analysis software. Corneal endothelial images from near the surgical limbus to limbus in all eyes were clearly recorded and panoramic images were made by combining still images. ECD in groups A, B and C were 2809±186, 2717±91 and 2580±129 cells/mm 2 at the centre, 2902±242, 2772±97 and 2604±187 cells/mm 2 at the mid-periphery and 2893±308, 2691±99 and 2533±112 cells/mm 2 at the periphery. Significance differences in ECD was found between groups A and C in all regions and groups between B and C at mid-peripheral region. A prototype slit-scanning wide-field contact specular microscope enabled us to record the endothelial layer from the surgical limbus to limbus of the cornea and compare specific areas among subjects, and showed that ECD in each region of the cornea decreases with ageing. UMIN000021264, Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Effect of Topically Applied Azithromycin on Corneal Epithelial and Endothelial Apoptosis in a Rat Model of Corneal Alkali Burn.

    PubMed

    Arikan, Sedat; Karaca, Turan; Ertekin, Yusuf Haydar; Comez, Arzu Taskiran; Ersan, Ismail; Demirtas, Selim; Elmas, Sait; Tufan, Hasan Ali; Turkon, Hakan

    2016-04-01

    To investigate the antiapoptotic effect of topically administered azithromycin (AZM) on corneal epithelial and endothelial cells in a rat model of corneal alkali burn. Twenty-four Wistar albino rats were divided into 4 equal groups as pseudovehicle (group 1), control (group 2), alkali burned (group 3), and treatment (group 4) groups. Alkali injury was induced only in the right corneas of rats belonging to groups 3 and 4 using 1N NaOH. The rats in group 3 and the rats in group 4 were respectively treated either with an artificial tear gel or with 1.5% AZM eye drops for 5 days. At the fifth day of the experiment, the apoptosis in the corneal epithelium and endothelium of all rats was assessed using a terminal dUTP nick-end labeling (TUNEL) assay. In addition, tumor necrosis factor-alpha (TNF-α) density in the corneal epithelium was measured in all rats. The mean numbers of TUNEL+ cells in the corneal epithelium and endothelium of rats in group 3 were 117.1 ± 23.8 and 34.6.± 11.3, respectively, whereas in group 4, they were 75.8 ± 15.7 and 14.7 ± 3.5, respectively. Also the mean TNF-α densities in the corneal epithelium in group 3 and group 4 were 2.65 ± 1.3 and 1.65 ± 1.1, respectively. There was a significant decrease in the mean number of TUNEL+ cells in the corneal epithelium and endothelium and in the mean TNF-α density in the corneal epithelium of rats in group 4, when compared with group 3. Topically applied AZM can decrease TNF-α-induced apoptosis in corneal alkali burn.

  8. Effect of gatifloxacin ophthalmic solution 0.3% on human corneal endothelial cell density and aqueous humor gatifloxacin concentration.

    PubMed

    Price, Marianne O; Quillin, Clorissa; Price, Francis W

    2005-07-01

    To evaluate the effect of gatifloxacin ophthalmic solution 0.3% (Zymar, Allergan, Inc., Irvine, CA, USA) on corneal endothelial cell density and morphology and to measure gatifloxacin penetration into aqueous humor. This was a single-center, open-label clinical study. Ten patients undergoing standard cataract surgery and 20 nonsurgical subjects instilled gatifloxacin 0.3% four times per day for 2 days, then every 10 min for 1 hr on the third day (the surgery day for the cataract patients). Corneal endothelial cells were counted using noncontact specular microscopy. Anterior chamber fluid was withdrawn from the surgical patients, and the gatifloxacin concentration was quantified by high-pressure liquid chromatography. Baseline endothelial cell counts (mean +/- SD) were 2400 +/- 442 in the surgical group and 2520 +/- 212 in the nonsurgical group. The mean differences from baseline 1 hr after the last dose of gatifloxacin 0.3% were -51 +/- 213 (p = 0.23) in the surgical group and -7 +/- 150 (p = 0.42) in the nonsurgical group. In the nonsurgical group, the mean difference from baseline 3 weeks after the last dose was 18 +/- 147 (p = 0.71). The mean concentration (+/- SD) of gatifloxacin in aqueous humor was 1.26 +/- 0.55 microg/ml. A preoperative, prophylactic course of gatifloxacin 0.3% ophthalmic solution did not significantly affect endothelial cell density or morphology, while meaningful drug concentration was achieved in the aqueous humor.

  9. CD147 Required for Corneal Endothelial Lactate Transport

    PubMed Central

    Li, Shimin; Nguyen, Tracy T.; Bonanno, Joseph A.

    2014-01-01

    Purpose. CD147/basigin is a chaperone for lactate:H+ cotransporters (monocarboxylate transporters) MCT1 and MCT4. We tested the hypothesis that MCT1 and -4 in corneal endothelium contribute to lactate efflux from stroma to anterior chamber and that silencing CD147 expression would cause corneal edema. Methods. CD147 was silenced via small interfering ribonucleic acid (siRNA) transfection of rabbit corneas ex vivo and anterior chamber lenti-small hairpin RNA (shRNA) pseudovirus in vivo. CD147 and MCT expression was examined by Western blot, RT-PCR, and immunofluorescence. Functional effects were examined by measuring lactate-induced cell acidification, corneal lactate efflux, [lactate], central cornea thickness (CCT), and Azopt (a carbonic anhydrase inhibitor) sensitivity. Results. In ex vivo corneas, 100 nM CD147 siRNA reduced CD147, MCT1, and MCT4 expression by 85%, 79%, and 73%, respectively, while MCT2 expression was unaffected. CD147 siRNA decreased lactate efflux from 3.9 ± 0.81 to 1.5 ± 0.37 nmol/min, increased corneal [lactate] from 19.28 ± 7.15 to 56.73 ± 8.97 nmol/mg, acidified endothelial cells (pHi = 6.83 ± 0.07 vs. 7.19 ± 0.09 in control), and slowed basolateral lactate-induced acidification from 0.0034 ± 0.0005 to 0.0012 ± 0.0005 pH/s, whereas apical acidification was unchanged. In vivo, CD147 shRNA increased CCT by 28.1 ± 0.9 μm at 28 days; Azopt increased CCT to 24.4 ± 3.12 vs. 12.0 ± 0.48 μm in control, and corneal [lactate] was 47.63 ± 6.29 nmol/mg in shCD147 corneas and 17.82 ± 4.93 nmol/mg in paired controls. Conclusions. CD147 is required for the expression of MCT1 and MCT4 in the corneal endothelium. Silencing CD147 slows lactate efflux, resulting in stromal lactate accumulation and corneal edema, consistent with lactate efflux as a significant component of the corneal endothelial pump. PMID:24970254

  10. CD147 required for corneal endothelial lactate transport.

    PubMed

    Li, Shimin; Nguyen, Tracy T; Bonanno, Joseph A

    2014-06-26

    CD147/basigin is a chaperone for lactate:H(+) cotransporters (monocarboxylate transporters) MCT1 and MCT4. We tested the hypothesis that MCT1 and -4 in corneal endothelium contribute to lactate efflux from stroma to anterior chamber and that silencing CD147 expression would cause corneal edema. CD147 was silenced via small interfering ribonucleic acid (siRNA) transfection of rabbit corneas ex vivo and anterior chamber lenti-small hairpin RNA (shRNA) pseudovirus in vivo. CD147 and MCT expression was examined by Western blot, RT-PCR, and immunofluorescence. Functional effects were examined by measuring lactate-induced cell acidification, corneal lactate efflux, [lactate], central cornea thickness (CCT), and Azopt (a carbonic anhydrase inhibitor) sensitivity. In ex vivo corneas, 100 nM CD147 siRNA reduced CD147, MCT1, and MCT4 expression by 85%, 79%, and 73%, respectively, while MCT2 expression was unaffected. CD147 siRNA decreased lactate efflux from 3.9 ± 0.81 to 1.5 ± 0.37 nmol/min, increased corneal [lactate] from 19.28 ± 7.15 to 56.73 ± 8.97 nmol/mg, acidified endothelial cells (pHi = 6.83 ± 0.07 vs. 7.19 ± 0.09 in control), and slowed basolateral lactate-induced acidification from 0.0034 ± 0.0005 to 0.0012 ± 0.0005 pH/s, whereas apical acidification was unchanged. In vivo, CD147 shRNA increased CCT by 28.1 ± 0.9 μm at 28 days; Azopt increased CCT to 24.4 ± 3.12 vs. 12.0 ± 0.48 μm in control, and corneal [lactate] was 47.63 ± 6.29 nmol/mg in shCD147 corneas and 17.82 ± 4.93 nmol/mg in paired controls. CD147 is required for the expression of MCT1 and MCT4 in the corneal endothelium. Silencing CD147 slows lactate efflux, resulting in stromal lactate accumulation and corneal edema, consistent with lactate efflux as a significant component of the corneal endothelial pump. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  11. Protocol for vital dye staining of corneal endothelial cells.

    PubMed

    Park, Sunju; Fong, Alan G; Cho, Hyung; Zhang, Cheng; Gritz, David C; Mian, Gibran; Herzlich, Alexandra A; Gore, Patrick; Morganti, Ashley; Chuck, Roy S

    2012-12-01

    To describe a step-by-step methodology to establish a reproducible staining protocol for the evaluation of human corneal endothelial cells. Four procedures were performed to determine the best protocol. (1) To determine the optimal trypan blue staining method, goat corneas were stained with 4 dilutions of trypan blue (0.4%, 0.2%, 0.1%, and 0.05%) and 1% alizarin red. (2) To determine the optimal alizarin red staining method, goat corneas were stained with 2 dilutions of alizarin red (1% and 0.5%) and 0.2% trypan blue. (3) To ensure that trypan blue truly stains damaged cells, goat corneas were exposed to either 3% hydrogen peroxide or to balanced salt solution, and then stained with 0.2% trypan blue and 0.5% alizarin red. (4) Finally, fresh human corneal buttons were examined; 1 group was stained with 0.2% trypan blue and another group with 0.4% trypan blue. For the 4 procedures performed, the results are as follows: (1) trypan blue staining was not observed in any of the normal corneal samples; (2) 0.5% alizarin red demonstrated sharper cell borders than 1% alizarin red; (3) positive trypan blue staining was observed in the hydrogen peroxide exposed tissue in damaged areas; (4) 0.4% trypan blue showed more distinct positive staining than 0.2% trypan blue. We were able to determine the optimal vital dye staining conditions for human corneal endothelial cells using 0.4% trypan blue and 0.5% alizarin red.

  12. Fabrication of a corneal model composed of corneal epithelial and endothelial cells via a collagen vitrigel membrane functioned as an acellular stroma and its application to the corneal permeability test of chemicals.

    PubMed

    Yamaguchi, Hiroyuki; Takezawa, Toshiaki

    2018-05-29

    A collagen vitrigel membrane (CVM) we developed can function as both a scaffold for cells and a pathway for chemicals. To extrapolate the corneal permeability of chemicals in vivo, we proposed six corneal models using the CVM. Thin and thick CVMs were utilized as models for Bowman's membrane (BM) and an acellular-stroma (AS), respectively. Models for a corneal epithelium (CEpi), a corneal epithelium-acellular stroma (CEpi-AS), a corneal epithelium-endothelium (CEpi-Endo) and a corneal epithelium-acellular stroma-endothelium (CEpi-AS-Endo) were fabricated by culturing corneal epithelial cells and/or corneal endothelial cells on the surface of CVMs. Subsequently, the permeability coefficient (P app ) value of each model was calculated using five chemicals with different molecular radii; cyanocobalamin and four FITC-dextrans (FD-4, FD-10, FD-20 and FD-40). The slopes of P app versus molecular radii of those chemicals in the both BM and AS models were almost similar to data using an excised rabbit corneal stroma. The ratios of P app values in models for BM, CEpi and CEpi-Endo against those in data using an excised rabbit cornea were calculated as 75.4, 6.4 and 4.5-folds for FD-4 and 38.7, 10.0 and 4.2-folds for FD-10, respectively. Similarly, those in models for AS, CEpi-AS and CEpi-AS-Endo were calculated as 26.1, 2.5 and 0.6-folds for FD-4 and 26.1, 1.5 and 0.6-folds for FD-10, respectively. These results suggest that the CEpi-AS-Endo model with both the barrier function of corneal cell layers and the diffusion capacity of chemicals in thick CVM is most appropriate for extrapolating the corneal permeability of chemicals in vivo . The American Society for Pharmacology and Experimental Therapeutics.

  13. Pseudophakodonesis and corneal endothelial contact: direct observations by high-speed cinematography.

    PubMed Central

    Jacobs, P M; Cheng, H; Price, N C

    1983-01-01

    High-speed cinematography was used to observe the movement of Federov type I lens implants within the anterior chamber. Our measurements suggest that in most patients contact between the lens implant and corneal endothelium does not occur. Images PMID:6615750

  14. Role of computer-assisted analysis of the corneal endothelium in vitreoretinal surgery with intraocular silicone oil injection: a technical report.

    PubMed

    Fruschelli, M; Esposti, P; Caporossi, A

    1998-01-01

    The innermost lining of the cornea consists of a single layer of cells called the endothelium. Despite its name, the endothelium of the cornea differs considerably from the vascular endothelium, both functionally and morphologically. The corneal endothelium plays a fundamental role in maintaining the transparency of the corneal membrane, as the result of both its function as a barrier against penetration of the aqueous humor in the parenchyma and its ability to remove water from the stroma (usually referred to as the endothelial "pump" function). Any abnormality in the corneal endothelium causes, first, the impairment of its function as a barrier and pump due to the loss of stromal anti-turgor mechanisms, followed by edema and possible development into keratopathy. The specular microscope is an instrument which makes it possible to see the endothelial "mosaic" in the reflected image of the posterior corneal surface. A large variety of clinical specular microscopes is presently available, both contact and non-contact, which allow, for easy and rapid photography of the corneal endothelium "in vivo". In the present case, we used a non-contact computerized specular microscope to analyze the corneal endothelium in a group of patients affected by retinal detachment who needed to undergo vitreoretinal surgery with immission of silicone oil into the vitreal chamber.

  15. Thick keratoconic cornea associated with posterior polymorphous corneal dystrophy.

    PubMed

    Zaarour, K; Slim, E; Antoun, J; Waked, N

    2017-03-01

    We herein report a case of bilateral unusually thick non-edematous keratoconic corneas with associated endothelial features of posterior polymorphous corneal dystrophy (PPCD). We report the case of a 27-year-old myopic woman who presented for refractive surgery. Slit lamp exam showed bilateral corneal protrusion with diffuse deep stromal and endothelial vesicular opacities and small paracentral bands. Topography showed generalized advanced corneal steepening in both eyes with increased anterior and posterior central corneal elevations in comparison to the best fit sphere. Ultrasound pachymetry showed central corneal thickness of 605μm (RE) and 612μm (LE). On specular biomicroscopy, cell density of 2503 cells/mm 2 RE and 1526 cells/mm 2 LE with significant cellular pleomorphism and polymegathism were noted. Clinical and paraclinical findings together suggest the presence of simultaneous keratoconus and PPCD. The literature has suggested an association between PPCD and steep cornea. Moreover, many reports have also described cases of associated PPCD and keratoconus with characteristic thinning and ectasia, in comparison to the unusual thick corneas noted in our patient, despite the absence of edema. Identification of genetics factors is further needed to clarify this association. This case describes a patient whose corneas present features of both keratoconus and PPCD and is unique due to the presence of increased corneal thickness despite the absence of edema. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Eye-bank preparation of endothelial tissue.

    PubMed

    Boynton, Grace E; Woodward, Maria A

    2014-07-01

    Eye-bank preparation of endothelial tissue for keratoplasty continues to evolve. Although eye-bank personnel have become comfortable and competent at Descemet's stripping automated endothelial keratoplasty (DSAEK), tissue preparation and tissue transport, optimization of preparation methods continues. Surgeons and eye-bank personnel should be up to date on the research in the field. As surgeons transit to Descemet's membrane endothelial keratoplasty (DMEK), eye banks have risen to the challenge of preparing tissue. Eye banks are refining their DMEK preparation and transport techniques. This article covers refinements to DSAEK tissue preparation, innovations to prepare DMEK tissue, and nuances to improve donor cornea tissue quality. As eye bank-supplied corneal tissue is the main source of tissue for many corneal surgeons, it is critical to stay informed about tissue handling and preparation. Ultimately, the surgeon is responsible for the transplantation, so involvement of clinicians in eye-banking practices and advocacy for pursuing meaningful research in this area will benefit clinical patient outcomes.

  17. Cellular Therapy With Human Autologous Adipose-Derived Adult Stem Cells for Advanced Keratoconus.

    PubMed

    Alió Del Barrio, Jorge L; El Zarif, Mona; de Miguel, María P; Azaar, Albert; Makdissy, Norman; Harb, Walid; El Achkar, Ibrahim; Arnalich-Montiel, Francisco; Alió, Jorge L

    2017-08-01

    The aim of this phase 1 study was to preliminarily evaluate the safety and efficacy of autologous adipose-derived adult stem cell (ADASC) implantation within the corneal stroma of patients with advanced keratoconus. Five consecutive patients were selected. Autologous ADASCs were obtained by elective liposuction. ADASCs (3 × 10) contained in 1 mL saline were injected into the corneal stroma through a femtosecond-assisted 9.5-mm diameter lamellar pocket under topical anesthesia. Patients were reviewed at 1 day, 1 week, 1, 3, and 6 months postoperatively. Visual function, manifest refraction, slit-lamp biomicroscopy, intraocular pressure, endothelial cell density, corneal topography, corneal optical coherence tomography, and corneal confocal biomicroscopy were recorded. No intraoperative or postoperative complications were recorded, with full corneal transparency recovery within 24 hours. Four patients completed the full follow-up. All patients improved their visual function (mean: 1 line of unaided and spectacle-corrected distance vision and 2 lines of rigid contact lens distance vision). Manifest refraction and topographic keratometry remained stable. Corneal optical coherence tomography showed a mean improvement of 16.5 μm in the central corneal thickness, and new collagen production was observed as patchy hyperreflective areas at the level of the stromal pocket. Confocal biomicroscopy confirmed the survival of the implanted stem cells at the surgical plane. Intraocular pressure and endothelial cell density remained stable. Cellular therapy of the human corneal stroma in vivo with autologous ADASCs appears to be safe. Stem cells survive in vivo with intrastromal new collagen production. Future studies with larger samples are required to confirm these preliminary results.

  18. Assessment of eye bank-prepared posterior lamellar corneal tissue for endothelial keratoplasty.

    PubMed

    Rose, Linda; Briceño, César A; Stark, Walter J; Gloria, Dante G; Jun, Albert S

    2008-02-01

    To evaluate eye bank-prepared tissue for Descemet's stripping automated endothelial keratoplasty (DSAEK). Experimental study and retrospective case series. Seventeen human donor corneas and 4 recipient patients undergoing DSAEK surgery. Corneal-scleral discs were obtained. Specular microscopy and pachymetry were performed. A designated Tissue Banks International technician used a microkeratome to prepare a flap. Posterior bed thickness was measured. The sectioned tissue was stored, and at 24 and 48 hours, pachymetry was repeated. At 48 hours, specular microscopy was repeated, and endothelial cell viability was assessed with trypan blue. Descemet's stripping automated endothelial keratoplasty was performed in 4 patients using eye bank-prepared posterior lamellar tissue. Corneal tissue was assessed with the following parameters: corneal thickness measured with ultrasonic pachymetry, cell density counts measured with a keratoanalyzer, and cell viability as observed with trypan blue exclusion. Patient outcomes were measured by changes in visual acuity (VA) and the presence of a clear graft. Donor corneal pachymetry before sectioning averaged 599+/-52 microm. Immediately after sectioning with a microkeratome set at a depth of 300 microm, mean posterior bed thickness was 328+/-95 microm. Thus, the mean cutting depth achieved by the microkeratome when set at 300 micrometers averaged 271+/-83 microm. After storage for 24 hours, the posterior beds measured 352 microm, an average swelling of 24 (7%) microm (P = 0.14). After 48 hours, the posterior beds measured 382 microm, an average swelling of 54 (16%) microm (P = 0.02). Cell counts 48 hours after sectioning decreased by an average of 11% (P = 0.10). Endothelial cell staining confirmed improvement in postsectioning morphology and survival with increased technician experience. All 4 patients receiving eye bank-prepared DSAEK tissue showed uncomplicated postoperative results, with improvement in VA. The microkeratome cutting depth was moderately accurate. Pachymetry, cell density, and cell viability of sectioned tissue after 48 hours in storage were encouraging overall. Initial clinical results of eye bank-prepared DSAEK tissue showed uncomplicated postoperative courses and improved VA. Additional studies are needed to follow the long-term outcomes in the recipients of these tissues.

  19. Laser-assisted corneal welding in cataract surgery: retrospective study.

    PubMed

    Menabuoni, Luca; Pini, Roberto; Rossi, Francesca; Lenzetti, Ivo; Yoo, Sonia H; Parel, Jean-Marie

    2007-09-01

    To evaluate the efficacy of laser welding to close corneal wounds in cataract surgery. Department of Ophthalmology, Hospital of Misericordia e Dolce, Prato, Italy. This retrospective nonrandomized interventional case series included 20 eyes of 20 patients. All eyes had cataract with visual acuity worse than 20/200. Ten patients had phacoemulsification surgery, and 10 had extracapsular cataract extraction (ECCE). Surgeries were followed by laser-assisted closure of the corneal wounds by diode laser welding of the stroma using a technique established in animal models. Preoperative and postoperative (1, 3, 7, 30, and 90 days) astigmatism, level of inflammation, Seidel testing, and endothelial cell counts were obtained. There were minor differences in preoperative and postoperative astigmatism except in 1 eye in the ECCE group. The Seidel test showed no wound leakage during the follow-up examinations, and endothelial cell loss was similar to that published for standard surgical cataract procedures. No collateral effects of the laser welding were detected, nor was postoperative inflammation. Astigmatism was slightly affected by the use of laser welding for corneal wound closure after phacoemulsification and ECCE. The laser-assisted corneal sealing procedure was rapid and safe and could serve as an alternative to corneal suturing, with significant potential applications for the closure of longer incisions, such as those used in penetrating keratoplasty.

  20. Optimized human platelet lysate as novel basis for a serum-, xeno-, and additive-free corneal endothelial cell and tissue culture.

    PubMed

    Thieme, Daniel; Reuland, Lynn; Lindl, Toni; Kruse, Friedrich; Fuchsluger, Thomas

    2018-02-01

    The expansion of donor-derived corneal endothelial cells (ECs) is a promising approach for regenerative therapies in corneal diseases. To achieve the best Good Manufacturing Practice standard the entire cultivation process should be devoid of nonhuman components. However, so far, there is no suitable xeno-free protocol for clinical applications. We therefore introduce a processed variant of a platelet lysate for the use in corneal cell and tissue culture based on a Good Manufacturing Practice-grade thrombocyte concentrate. This processed human platelet lysate (phPL), free of any animal components and of anticoagulants such as heparin with a physiological ionic composition, was used to cultivate corneal ECs in vitro and ex vivo in comparison to standard cultivation with fetal calf serum (FCS). Human donor corneas were cut in quarters while 2 quarters of each cornea were incubated with the respective medium supplement. Three fields of view per quarter were taken into account for the analysis. Evaluation of phPL as a medium supplement in cell culture of immortalized EC showed a superior viability compared with FCS control with reduced cell proliferation. Furthermore, the viability during the expansion of primary cells is significantly (3-fold ±0.5) increased with phPL compared with FCS standard medium. Quartering donor corneas was traumatic for the endothelium and therefore resulted in increased EC loss. Interestingly, however, cultivation of the quartered pieces for 2 weeks in 0.1-mg/ml pHPL in Biochrome I showed a 21 (±10) % EC loss compared with 67 (±12) % EC loss when cultivated in 2% FCS in Biochrome I. The cell culture protocol with pHPL as FCS replacement seems to be superior to the standard FCS protocols with respect to EC survival. It offers a xeno-free and physiological environment for corneal endothelial cells. This alternative cultivation protocol could facilitate the use of EC for human corneal cell therapy. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Preliminary study of the association between corneal histocytological changes and surgically induced astigmatism after phacoemulsification.

    PubMed

    Du, Xing; Zhao, Guiqiu; Wang, Qing; Yang, Xian; Gao, Ang; Lin, Jing; Wang, Qian; Xu, Qiang

    2014-11-20

    Surgically induced astigmatism (SIA) was one of the factors that influences the desirable refractive outcome, and it was related to the length, type, location, structure of the incision and to the suture closure technique, etc. The aim was to evaluate the association of corneal histocytological changes with SIA after phacoemulsification. The study enrolled 68 cases of cataract patient (68 eyes). Corneal histocytological parameters at corneal incision, central cornea and contralateral incision obtained by confocal microscope through focusing (CMTF) were compared preoperatively and 1 week, 2 weeks, 1 month, 3 months and 6 months postoperatively. These biometric parameters included the endothelial cell density, keratocyte density of posterior stromal layer, and the morphological changes. SIA was calculated by Jaffe's vector analysis. 1 From preoperatively to 1 week, 2 weeks, 1 month, 3 months and 6 months postoperatively, the endothelail cell density was decreased significantly (p < 0.05). Keratocyte density of posterior stroma layer was increased significantly only at 1 week, 2 weeks, 1 month, 3 months postoperatively (p <0.05), but not statistically significant (p = 0.173) at 6 months postoperatively compared to preoperative values. 2 The histocytological observations indicated that the morphology changed significantly postoperatively at the corneal incision, including the cell absent area, wave-like area, dot-like and mass-like hyperreflection, stripe-like absent area, in the endothelial layer, and the keratocyte activation, microfolds, irregular hyporeflective or hyperreflective belt, and a little dot-like hyperreflection in the posterior stroma layer. 3 The reduction of the endothelial cell density at the corneal incision at 1 week, 2 weeks, 1 month postoperatively, were positively correlated with SIA (P1 week = 0.003, P2 weeks = 0.003, P1 month = 0.032), while others were not associated with SIA statistically. The reduction of endothelail cell density and the histocytological changes at the corneal incision were associated with SIA. The underlining mechanism needs further study.

  2. The Comparison between Torsional and Conventional Mode Phacoemulsification in Moderate and Hard Cataracts

    PubMed Central

    Kim, Dong-Hyun; Wee, Won-Ryang; Lee, Jin-Hak

    2010-01-01

    Purpose To compare the intraoperative performances and postoperative outcomes of cataract surgery performed with longitudinal phacoemulsification and torsional phacoemulsification in moderate and hard cataracts. Methods Of 85 patients who had senile cataracts, 102 eyes were operated on using the Infiniti Vision System. Preoperative examinations (slit lamp examination, mean central corneal thickness, and central endothelial cell counts) were performed for each patient. Cataracts were subdivided into moderate and hard, according to the Lens Opacities Classification System III grading of nucleus opalescence (NO). Eyes in each cataract group were randomly assigned to conventional and torsional phaco-mode. Intraoperative parameters, including ultrasound time (UST), cumulative dissipated energy (CDE), and the balanced salt solution plus (BSSP) volume utilized were evaluated. Best corrected visual acuity (BCVA) was checked on postoperative day 30; mean central corneal thickness and central endothelial cell counts were investigated on postoperative days 7 and 30. Results Preoperative BCVA and mean grading of NO showed no difference in both groups. Preoperative endothelial cell count and central corneal thickness also showed no significant difference in both groups. In the moderate cataract group, the CDE, UST, and BSSP volume were significantly lower in the torsional mode than the longitudinal mode, but they did not show any difference in the hard cataract group. Torsional group showed less endothelial cell loss and central corneal thickening at postoperative day seven in moderate cataracts but showed no significant differences, as compared with the longitudinal group, by postoperative day 30. Conclusions Torsional phacoemulsification showed superior efficiency for moderate cataracts, as compared with longitudinal phacoemulsification, in the early postoperative stage. PMID:21165231

  3. The comparison between torsional and conventional mode phacoemulsification in moderate and hard cataracts.

    PubMed

    Kim, Dong-Hyun; Wee, Won-Ryang; Lee, Jin-Hak; Kim, Mee-Kum

    2010-12-01

    To compare the intraoperative performances and postoperative outcomes of cataract surgery performed with longitudinal phacoemulsification and torsional phacoemulsification in moderate and hard cataracts. Of 85 patients who had senile cataracts, 102 eyes were operated on using the Infiniti Vision System. Preoperative examinations (slit lamp examination, mean central corneal thickness, and central endothelial cell counts) were performed for each patient. Cataracts were subdivided into moderate and hard, according to the Lens Opacities Classification System III grading of nucleus opalescence (NO). Eyes in each cataract group were randomly assigned to conventional and torsional phaco-mode. Intraoperative parameters, including ultrasound time (UST), cumulative dissipated energy (CDE), and the balanced salt solution plus (BSSP) volume utilized were evaluated. Best corrected visual acuity (BCVA) was checked on postoperative day 30; mean central corneal thickness and central endothelial cell counts were investigated on postoperative days 7 and 30. Preoperative BCVA and mean grading of NO showed no difference in both groups. Preoperative endothelial cell count and central corneal thickness also showed no significant difference in both groups. In the moderate cataract group, the CDE, UST, and BSSP volume were significantly lower in the torsional mode than the longitudinal mode, but they did not show any difference in the hard cataract group. Torsional group showed less endothelial cell loss and central corneal thickening at postoperative day seven in moderate cataracts but showed no significant differences, as compared with the longitudinal group, by postoperative day 30. Torsional phacoemulsification showed superior efficiency for moderate cataracts, as compared with longitudinal phacoemulsification, in the early postoperative stage.

  4. Comparison of ultrasonic energy expenditures and corneal endothelial cell density reductions during modulated and non-modulated phacoemulsification.

    PubMed

    Davison, James A

    2007-01-01

    To compare the Legacy 20000 Advantec continuous and Infiniti hyperpulse modes (Alcon Laboratories, Fort Worth, TX) with respect to average power, machine-measured phacoemulsification time, total stopwatch real time spent within the phacoemulsification process, balanced salt solution (BSS) volume, and corneal endothelial cell density losses. A background study was done of consecutive patients operated on with the Legacy (n = 60) and Infiniti (n = 40) machines programmed with identical parameters and using the continuous mode only. A primary study of another set of consecutive cases was operated on using the Legacy (n = 87) and Infiniti (n = 94) with the same parameters, but using the hyperpulse mode during quadrant removal with the Infiniti. Measurements for each set included average power and phacoemulsification time with corneal endothelial cell densities, BSS volume, and time spent in the phacoemulsification process. Similarities were found in the background study for average power percent and average minutes of phacoemulsification time. In the primary study, similarities were found for total minutes in the phacoemulsification process, BSS usage, and ECD losses, and differences were found for average power percent (P< .001) and machine-measured phacoemulsification minutes (P< .001). The Legacy and Infiniti performed similarly in continuous mode. With the Infiniti hyperpulse mode, a total ultrasonic energy reduction of 66% was noted. The machines required the same amount of total stopwatch measured time to accomplish phacoemulsification and produced the same 5% corneal endothelial cell loss. Therefore, clinically, these two machines behave in a comparable manner relative to safety and effectiveness.

  5. Effects of Repeated Intravitreal Aflibercept Injection on the Corneal Endothelium in Patients With Age-Related Macular Degeneration: Outcomes From the RE-VIEW Study.

    PubMed

    Lass, Jonathan H; Benetz, Beth Ann; Menegay, Harry J; Tsipis, Constantinos P; Cook, Jane Caty; Boyer, David S; Singer, Michael; Erickson, Kristine; Saroj, Namrata; Vitti, Robert; Chu, Karen W; Moini, Hadi; Soo, Yuhwen; Cheng, Yenchieh

    2018-05-01

    The effects of repeated intravitreal aflibercept injection (IAI) on the corneal endothelium were studied in patients with unilateral neovascular age-related macular degeneration. RE-VIEW was a phase 4, open-label, single-arm, multicenter study. Patients received IAI every 8 weeks after 3 monthly doses. Slit-lamp biomicroscopy was performed at all study visits. The central corneal endothelial health was evaluated by specular microscopy in the treated versus untreated fellow eyes at baseline and weeks 24 and 52. No slit-lamp abnormalities were noted in 154 enrolled patients (eyes). Baseline versus 52-week mean (±SD) endothelial morphometric values (n = 118) for the treated versus untreated fellow eyes were respectively as follows: endothelial cell density was 2410 ± 364 versus 2388 ± 384 cells/mm at baseline and remained unchanged at 2401 ± 353 versus 2376 ± 364 cells/mm at 52 weeks (P = 0.87); the coefficient of variation was 33.5 ± 4.4% versus 34.0 ± 5.0% at baseline and remained unchanged at 34.2 ± 4.7% versus 34.1 ± 4.9% at 52 weeks (P = 0.18); the percentage of hexagonal cells was 59.5 ± 5.8% versus 59.6 ± 6.4% at baseline and remained unchanged at 59.5 ± 6.0% versus 59.5 ± 5.8% at 52 weeks (P = 0.96). Repeated IAI for 52 weeks had no apparent corneal endothelial toxicity noted on specular microscopy in patients treated for neovascular age-related macular degeneration.

  6. Transient corneal endothelial changes following accelerated collagen cross-linking for the treatment of progressive keratoconus.

    PubMed

    Cingü, Abdullah Kürşat; Sogutlu-Sari, Esin; Cınar, Yasin; Sahin, Muhammed; Türkçü, Fatih Mehmet; Yüksel, Harun; Sahin, Alparslan; Caça, Ihsan

    2014-06-01

    To evaluate the corneal endothelial changes following accelerated collagen cross-linking (CXL) for the treatment of progressive keratoconus. Thirty-six consecutive progressive keratoconus patients who received accelerated CXL treatment were enrolled in the study. Following de-epithelization, isoosmolar 0.1% riboflavin solution without dextran was instilled every 3 min throughout the 30 min of soaking time before the 5 min of 18 mW/cm(2) UVA irradiation and every 2 min during the UVA irradiation. Corneal specular microscopy was performed on both treated and fellow eyes of each patient preoperatively, in the first week, and in the first, third and sixth month postoperatively. There were significant differences in endothelial cell density (ECD), percentages of hexagonality (6A) and coefficient of variation of endothelial cell area (CV) in the first week and first month postoperatively in the treated eyes when compared to their preoperative values and also to the first week and first month ECD, 6A and CV values of the non-operative eyes. ECD returned to the preoperative values at sixth month whereas 6A and CV returned to the preoperative values at third month. Our results suggested that there may be transient changes in human corneal endothelium following accelerated UVA/riboflavin CXL. Resolution of these changes during the follow-up may indicate a safe recovery. However, the treatment guidelines for accelerated CXL including irradiance level and soaking time should be clearly established to minimize the toxic effects of the treatment.

  7. NaCl osmotic perturbation can modulate hydration control in rabbit cornea.

    PubMed

    Ruberti, Jeffrey W; Klyce, Stephen D

    2003-03-01

    The corneal endothelium transports solute from the stroma to the aqueous humor, maintaining corneal hydration. Currently, little is known about how this active transport system is controlled. The purpose of this study is to investigate in greater detail the corneal response to small NaCl osmotic perturbations using a more refined automatic thickness measurement system in a search for response signatures of transport control. Adult New Zealand White rabbit corneas were debrided of their epithelium, excised and mounted in perfusion chambers. The endothelium, thus isolated, was bathed in isotonic Glutathione Bicarbonate Ringer's (GBR) solution and the bare anterior stroma was covered with silicone oil. Following stabilization in isotonic GBR, the endothelial perfusate was altered by +/-15 mOsm or+/-45 mOsm for 1 hr and 45 min by addition or removal of NaCl and returned (reversal) to GBR for 1 hr and 45 min. An enhanced, automatic scanning specular microscope monitored stromal thickness. The effective membrane transport coefficients were determined from the stromal thickness vs. time curves using an established numerical model of corneal hydration dynamics. It was found that the small (+/-15 mOsm) NaCl perturbations of the rabbit corneal endothelium resulted in a rapid trans-endothelial stromal volume control response that was not reversible after return to GBR. Long after the expected dissipation of the induced transients, this thickness 'controlling' response ultimately resulted in a sustained net thinning of 14 microm following the hypotonic perturbation and reversal, and a net swelling of 16 microm following the hypertonic perturbation and reversal. Model calculations indicated that the change induced by the perturbation could be explained by an immediate and persistent reduction of the passive endothelial NaCl permeability by 26% for the -15 mOsm perturbation compared to the +15 mOsm perturbation. This change persisted even after return to GBR. In contrast, the larger (+/-45 mOsm) perturbations did not elicit a similar response consistently. Our data suggest that trans-endothelial fluid transport can be rapidly modulated to control stromal hydration in response to small NaCl osmotic stresses in a way that cushions the shock and reduces the change in corneal thickness. Moreover, this behavior is not reversible in the short term, and may assist the regulation of corneal hydration homeostatically.

  8. Corneal endothelial cell density and morphology in Phramongkutklao Hospital

    PubMed Central

    Sopapornamorn, Narumon; Lekskul, Manapon; Panichkul, Suthee

    2008-01-01

    Objective To describe the corneal endothelial density and morphology in patients of Phramongkutklao Hospital and the relationship between endothelial cell parameters and other factors. Methods Four hundred and four eyes of 202 volunteers were included. Noncontact specular microscopy was performed after taking a history and testing the visual acuity, intraocular pressure measurement, Schirmer’s test and routine eye examination by slit lamp microscope. The studied parameters included mean endothelial cell density (MCD), coefficient of variation (CV), and percentage of hexagonality. Results The mean age of volunteers was 45.73 years; the range being 20 to 80 years old. Their MCD (SD), mean percentage of CV (SD) and mean (SD) percentage of hexagonality were 2623.49(325) cell/mm2, 39.43(8.23)% and 51.50(10.99)%, respectively. Statistically, MCD decreased significantly with age (p < 0.01). There was a significant difference in the percentage of CV between genders. There was no statistical significance between parameters and other factors. Conclusion The normative data of the corneal endothelium of Thai eyes indicated that, statistically, MCD decreased significantly with age. Previous studies have reported no difference in MCD, percentage of CV, and percentage of hexagonality between gender. Nevertheless, significantly different percentages of CV between genders were presented in this study. PMID:19668398

  9. Preparation of arginine-glycine-aspartic acid-modified biopolymeric nanoparticles containing epigalloccatechin-3-gallate for targeting vascular endothelial cells to inhibit corneal neovascularization.

    PubMed

    Chang, Che-Yi; Wang, Ming-Chen; Miyagawa, Takuya; Chen, Zhi-Yu; Lin, Feng-Huei; Chen, Ko-Hua; Liu, Guei-Sheung; Tseng, Ching-Li

    2017-01-01

    Neovascularization (NV) of the cornea can disrupt visual function, causing ocular diseases, including blindness. Therefore, treatment of corneal NV has a high public health impact. Epigalloccatechin-3-gallate (EGCG), presenting antiangiogenesis effects, was chosen as an inhibitor to treat human vascular endothelial cells for corneal NV treatment. An arginine-glycine-aspartic acid (RGD) peptide-hyaluronic acid (HA)-conjugated complex coating on the gelatin/EGCG self-assembly nanoparticles (GEH-RGD NPs) was synthesized for targeting the α v β 3 integrin on human umbilical vein endothelial cells (HUVECs) in this study, and a corneal NV mouse model was used to evaluate the therapeutic effect of this nanomedicine used as eyedrops. HA-RGD conjugation via COOH and amine groups was confirmed by 1 H-nuclear magnetic resonance and Fourier-transform infrared spectroscopy. The average diameter of GEH-RGD NPs was 168.87±22.5 nm with positive charge (19.7±2 mV), with an EGCG-loading efficiency up to 95%. Images of GEH-RGD NPs acquired from transmission electron microscopy showed a spherical shape and shell structure of about 200 nm. A slow-release pattern was observed in the nanoformulation at about 30% after 30 hours. Surface plasmon resonance confirmed that GEH-RGD NPs specifically bound to the integrin α v β 3 . In vitro cell-viability assay showed that GEH-RGD efficiently inhibited HUVEC proliferation at low EGCG concentrations (20 μg/mL) when compared with EGCG or non-RGD-modified NPs. Furthermore, GEH-RGD NPs significantly inhibited HUVEC migration down to 58%, lasting for 24 hours. In the corneal NV mouse model, fewer and thinner vessels were observed in the alkali-burned cornea after treatment with GEH-RGD NP eyedrops. Overall, this study indicates that GEH-RGD NPs were successfully developed and synthesized as an inhibitor of vascular endothelial cells with specific targeting capacity. Moreover, they can be used in eyedrops to inhibit angiogenesis in corneal NV mice.

  10. Preparation of arginine–glycine–aspartic acid-modified biopolymeric nanoparticles containing epigalloccatechin-3-gallate for targeting vascular endothelial cells to inhibit corneal neovascularization

    PubMed Central

    Chang, Che-Yi; Wang, Ming-Chen; Miyagawa, Takuya; Chen, Zhi-Yu; Lin, Feng-Huei; Chen, Ko-Hua; Liu, Guei-Sheung; Tseng, Ching-Li

    2017-01-01

    Neovascularization (NV) of the cornea can disrupt visual function, causing ocular diseases, including blindness. Therefore, treatment of corneal NV has a high public health impact. Epigalloccatechin-3-gallate (EGCG), presenting antiangiogenesis effects, was chosen as an inhibitor to treat human vascular endothelial cells for corneal NV treatment. An arginine–glycine–aspartic acid (RGD) peptide–hyaluronic acid (HA)-conjugated complex coating on the gelatin/EGCG self-assembly nanoparticles (GEH-RGD NPs) was synthesized for targeting the αvβ3 integrin on human umbilical vein endothelial cells (HUVECs) in this study, and a corneal NV mouse model was used to evaluate the therapeutic effect of this nanomedicine used as eyedrops. HA-RGD conjugation via COOH and amine groups was confirmed by 1H-nuclear magnetic resonance and Fourier-transform infrared spectroscopy. The average diameter of GEH-RGD NPs was 168.87±22.5 nm with positive charge (19.7±2 mV), with an EGCG-loading efficiency up to 95%. Images of GEH-RGD NPs acquired from transmission electron microscopy showed a spherical shape and shell structure of about 200 nm. A slow-release pattern was observed in the nanoformulation at about 30% after 30 hours. Surface plasmon resonance confirmed that GEH-RGD NPs specifically bound to the integrin αvβ3. In vitro cell-viability assay showed that GEH-RGD efficiently inhibited HUVEC proliferation at low EGCG concentrations (20 μg/mL) when compared with EGCG or non-RGD-modified NPs. Furthermore, GEH-RGD NPs significantly inhibited HUVEC migration down to 58%, lasting for 24 hours. In the corneal NV mouse model, fewer and thinner vessels were observed in the alkali-burned cornea after treatment with GEH-RGD NP eyedrops. Overall, this study indicates that GEH-RGD NPs were successfully developed and synthesized as an inhibitor of vascular endothelial cells with specific targeting capacity. Moreover, they can be used in eyedrops to inhibit angiogenesis in corneal NV mice. PMID:28115846

  11. Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision.

    PubMed

    Assaf, Ahmed; Roshdy, Maged Maher

    2013-01-01

    This paper compares and evaluates the corneal morphological changes occurring after cataract surgery through a 2.2 mm corneal incision. We use two platforms for comparison and evaluation, transversal and torsional phacoemulsification. This study includes 139 consecutive cataractous eyes (nuclear color 2-4, according to the Lens Opacities Classification System III [LOCSIII]) of 82 patients undergoing cataract surgery through a 2.2 mm corneal incision. Two different phacoemulsification platforms were used and assigned randomly: we used the WhiteStar Signature(®) system with the Ellips™ FX transversal continuous ultrasound (US) mode for group I (mean age: 65.33 ± 6.97 years), and we used the Infiniti(®) system with the OZil(®) Intelligent Phaco (IP) torsional US mode for group II (mean age: 64.02 ± 7.55 years). The corneal endothelium and pachymetry were evaluated preoperatively and at 1 month postoperatively. Incision size changes were also evaluated. All surgeries were uneventful. Before intraocular lens implantation, the mean incision size was 2.24 ± 0.06 mm in both groups (P = 0.75). In terms of corneal endothelial cell density, neither preoperative (I vs II: 2304.1 ± 122.5 cell/mm(2) vs 2315.6 ± 83.1 cell/mm(2), P = 0.80) nor postoperative (I vs II: 2264.1 ± 124.3 cell/mm(2) vs 2270.3 ± 89.9 cell/mm(2), P = 0.98) differences between the groups were statistically significant. The mean endothelial cell density loss was 1.7% ± 1.6% and 2.0% ± 1.4% in groups I and II, respectively. Furthermore, no significant differences between groups I and II were found preoperatively (P = 0.40) and postoperatively (P = 0.68) in central pachymetry. With surgery, the mean increase in central pachymetry was 28.1 ± 23.6 μm and 24.0 ± 24.0 μm in groups I and II, respectively (P = 0.1). Ellips™ FX transversal and OZil(®) IP torsional phacoemulsification modes are safe for performing cataract surgery, inducing minimal corneal thickness and endothelial changes.

  12. Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision

    PubMed Central

    Assaf, Ahmed; Roshdy, Maged Maher

    2013-01-01

    Purpose This paper compares and evaluates the corneal morphological changes occurring after cataract surgery through a 2.2 mm corneal incision. We use two platforms for comparison and evaluation, transversal and torsional phacoemulsification. Patients and methods This study includes 139 consecutive cataractous eyes (nuclear color 2–4, according to the Lens Opacities Classification System III [LOCSIII]) of 82 patients undergoing cataract surgery through a 2.2 mm corneal incision. Two different phacoemulsification platforms were used and assigned randomly: we used the WhiteStar Signature® system with the Ellips™ FX transversal continuous ultrasound (US) mode for group I (mean age: 65.33 ± 6.97 years), and we used the Infiniti® system with the OZil® Intelligent Phaco (IP) torsional US mode for group II (mean age: 64.02 ± 7.55 years). The corneal endothelium and pachymetry were evaluated preoperatively and at 1 month postoperatively. Incision size changes were also evaluated. Results All surgeries were uneventful. Before intraocular lens implantation, the mean incision size was 2.24 ± 0.06 mm in both groups (P = 0.75). In terms of corneal endothelial cell density, neither preoperative (I vs II: 2304.1 ± 122.5 cell/mm2 vs 2315.6 ± 83.1 cell/mm2, P = 0.80) nor postoperative (I vs II: 2264.1 ± 124.3 cell/mm2 vs 2270.3 ± 89.9 cell/mm2, P = 0.98) differences between the groups were statistically significant. The mean endothelial cell density loss was 1.7% ± 1.6% and 2.0% ± 1.4% in groups I and II, respectively. Furthermore, no significant differences between groups I and II were found preoperatively (P = 0.40) and postoperatively (P = 0.68) in central pachymetry. With surgery, the mean increase in central pachymetry was 28.1 ± 23.6 μm and 24.0 ± 24.0 μm in groups I and II, respectively (P = 0.1). Conclusion Ellips™ FX transversal and OZil® IP torsional phacoemulsification modes are safe for performing cataract surgery, inducing minimal corneal thickness and endothelial changes. PMID:23326184

  13. Can Appropriate Systemic Treatment Help Protect the Cornea in Patients With Rheumatoid Arthritis? A Multidisciplinary Approach to Autoimmune Ocular Involvement.

    PubMed

    Amador-Patarroyo, Manuel J; Jalil-Florencia, Emilio; Otero-Marquez, Oscar; Molano-Gonzalez, Nicolás; Mantilla, Ruben D; Rojas-Villarraga, Adriana; Anaya, Juan-Manuel; Barraquer-Coll, Carmen

    2018-02-01

    To correlate rheumatologic with ophthalmic and laboratory findings in patients with rheumatoid arthritis (RA) to identify what effect these have on development of ocular disease. This is a cross-sectional study of 172 eyes of 86 patients with RA. Patients were examined by a group of rheumatologists. Sociodemographic, clinical, and laboratory data were collected. All patients underwent complete ophthalmologic examination including corneal topography and endothelial cell count. There was no significant correlation between RA-negative prognostic indicators (NPIs) and pathologic corneal findings. Patients using disease-modifying antirheumatic drugs (DMARDs) and antimalarial drugs had greater corneal volumes (mean difference 8.51 mm, 90% confidence interval [CI], 3.98-13.04, P = 0.004; and 2.24, 90% CI, 0.32-4.54, P = 0.048, respectively). Patients using azathioprine had lower endothelial cell counts compared with those using other drugs (mean difference 180 cells/mm, 90% CI, 69-291, P = 0.008). Patients using biologic DMARDs had better tear osmolarity values (between 280 and 300 mOsm/L) than patients not using them (mean difference 14.3 mOsm/L, P = 0.022). There was no correlation between NPIs of RA and positive keratoconus screening indices (Spearman correlation OD -0.013, P = 0.91; OS -0.033, P = 0.76). There was no clear correlation between RA-NPIs and pathologic corneal findings in our study. DMARDs treatment may help maintain corneal integrity in our patients and prevented collagenolytic manifestations of RA. Other medications such as azathioprine should be used carefully, as endothelial damage may potentially occur.

  14. Role of miR-132 in Angiogenesis after Ocular Infection with Herpes Simplex Virus

    PubMed Central

    Mulik, Sachin; Xu, John; Reddy, Pradeep B.J.; Rajasagi, Naveen K.; Gimenez, Fernanda; Sharma, Shalini; Lu, Patrick Y.; Rouse, Barry T.

    2013-01-01

    MicroRNAs (miRNAs) are small regulatory molecules that control diverse biological processes that include angiogenesis. Herpes simplex virus (HSV) causes a chronic immuno-inflammatory response in the eye that may result in corneal neovascularization during blinding immunopathological lesion stromal keratitis (SK). miR-132 is a highly conserved miRNA that is induced in endothelial cells in response to growth factors, such as vascular endothelial growth factor (VEGF). In this study, we show that miR-132 expression was up-regulated (10- to 20-fold) after ocular infection with HSV, an event that involved the production of both VEGF-A and IL-17. Consequently, blockade of VEGF-A activity using soluble VEGF receptor 1 resulted in significantly lower levels of corneal miR-132 after HSV infection. In addition, low levels of corneal miR-132 were detected in IL-17 receptor knockout mice after HSV infection. In vivo silencing of miR-132 by the provision of anti-miR-132 (antagomir-132) nanoparticles to HSV-infected mice led to reduced corneal neovascularization and diminished SK lesions. The anti-angiogenic effect of antagomir-132 was reflected by a reduction in angiogenic Ras activity in corneal CD31-enriched cells (presumably blood vessel endothelial cells) during SK. To our knowledge, this is one of the first reports of miRNA involvement in an infectious ocular disease. Manipulating miRNA expression holds promise as a therapeutic approach to control an ocular lesion that is an important cause of human blindness. PMID:22659469

  15. Role of miR-132 in angiogenesis after ocular infection with herpes simplex virus.

    PubMed

    Mulik, Sachin; Xu, John; Reddy, Pradeep B J; Rajasagi, Naveen K; Gimenez, Fernanda; Sharma, Shalini; Lu, Patrick Y; Rouse, Barry T

    2012-08-01

    MicroRNAs (miRNAs) are small regulatory molecules that control diverse biological processes that include angiogenesis. Herpes simplex virus (HSV) causes a chronic immuno-inflammatory response in the eye that may result in corneal neovascularization during blinding immunopathological lesion stromal keratitis (SK). miR-132 is a highly conserved miRNA that is induced in endothelial cells in response to growth factors, such as vascular endothelial growth factor (VEGF). In this study, we show that miR-132 expression was up-regulated (10- to 20-fold) after ocular infection with HSV, an event that involved the production of both VEGF-A and IL-17. Consequently, blockade of VEGF-A activity using soluble VEGF receptor 1 resulted in significantly lower levels of corneal miR-132 after HSV infection. In addition, low levels of corneal miR-132 were detected in IL-17 receptor knockout mice after HSV infection. In vivo silencing of miR-132 by the provision of anti-miR-132 (antagomir-132) nanoparticles to HSV-infected mice led to reduced corneal neovascularization and diminished SK lesions. The anti-angiogenic effect of antagomir-132 was reflected by a reduction in angiogenic Ras activity in corneal CD31-enriched cells (presumably blood vessel endothelial cells) during SK. To our knowledge, this is one of the first reports of miRNA involvement in an infectious ocular disease. Manipulating miRNA expression holds promise as a therapeutic approach to control an ocular lesion that is an important cause of human blindness. Copyright © 2012 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  16. Efficient and safe gene delivery to human corneal endothelium using magnetic nanoparticles.

    PubMed

    Czugala, Marta; Mykhaylyk, Olga; Böhler, Philip; Onderka, Jasmine; Stork, Björn; Wesselborg, Sebastian; Kruse, Friedrich E; Plank, Christian; Singer, Bernhard B; Fuchsluger, Thomas A

    2016-07-01

    To develop a safe and efficient method for targeted, anti-apoptotic gene therapy of corneal endothelial cells (CECs). Magnetofection (MF), a combination of lipofection with magnetic nanoparticles (MNPs; PEI-Mag2, SO-Mag5, PalD1-Mag1), was tested in human CECs and in explanted human corneas. Effects on cell viability and function were investigated. Immunocompatibility was assessed in human peripheral blood mononuclear cells. Silica iron-oxide MNPs (SO-Mag5) combined with X-tremeGENE-HP achieved high transfection efficiency in human CECs and explanted human corneas, without altering cell viability or function. Magnetofection caused no immunomodulatory effects in human peripheral blood mononuclear cells. Magnetofection with anti-apoptotic P35 gene effectively blocked apoptosis in CECs. Magnetofection is a promising tool for gene therapy of corneal endothelial cells with potential for targeted on-site delivery.

  17. A clinical assessment of the anterior eye in arc welders.

    PubMed

    Doughty, Michael J; Oblak, Emil

    2005-11-01

    Corneal irradiation with high doses of ultraviolet-B (UVB) has been shown to damage the corneal endothelium in animals. Human occupational exposure to ultraviolet radiation (UVR) in welding is considered a risk for endothelial damage but the evidence for such an effect is limited. External eye photographs and non-contact specular micrographs (Topcon SP2000-P) were obtained from 102 white males aged between 32 and 62 years, 51 being arc welders (with 24 +/- 7 years experience) and 51 office workers. Most welders reported repeated occupational exposure to UVR (that is, welder's 'flashes'). Welders reported a higher level of ocular symptoms and a higher prevalence of pingueculae (47 versus 12 per cent), but only one case with pterygium. The average endothelial cell areas were the same in welders and office workers (398 +/- 55 microm(2) versus 400 +/- 56 microm(2); p = 0.868) as were the endothelial cell density (ECD) values (2,555 +/- 342 cells/mm(2) versus 2,541 +/- 308 cells/mm(2); p = 0.825). ECD decreased with years of welding experience (p < 0.01) but not faster than the decrease in ECD due to age. Repeated occupational ultraviolet radiation exposure through welding is not associated with any obvious differences in the corneal endothelium. No differences were observed in either ECD or cell polymegethism. Despite the periodic welding flashes, the exposure levels are below those needed to cause damage to the corneal endothelium.

  18. [Influence AquaLase at corneal endothelial cells].

    PubMed

    Jirásková, N; Rozsíval, P; Ludvíková, M; Burova, M; Nekolová, J

    2009-07-01

    To assess the effect of the cleaning of the posterior capsule using pulses of balanced salt solution (BSS) on the corneal endothelial cells. This pilot study involves 43 patients with bilateral cataracts having lens removal using torsional phacoemulsification (Ozil, Infiniti, Alcon) and bimanul irrigation/aspiration (I/A). Posterior capsule of the right eye of each patient was cleaned using pulses of BSS (AquaLase, Infiniti, Alcon). Surgery was performed by one of 2 surgeons (NJ, PR), both eyes of each patient was operated on by the same surgeon. Best corrected visual acuity (BCVA), endotelial cell count and pachymetry were evaluated pre- and postoperatively as well as occurence af peri- and postoperative complications. Preoperative mean pachymetry (P) was 566 +/- 45 microm in the right eye (RE) and 562 +/- 42 microm in the left eye (LE), mean endotelial cell count (ECC) 2541 +/- 317 cells/mm2 (RE) and 2567 +/- 311 cells/mm2 (LE). Three months after surgery P was 557 +/- 43 microm (RE) and 558 +/- 45 microm (LE) and ECC 2368 +/- 416 cells/mm2 (RE) and 2396 +/- 417 cells/mm2 (LE). There was no statistical difference in postoperative changes of both corneal parameters between right and left eyes. Best corrected visual acuity improved in all eyes and no peri-or postoperative complications occured. Cleaning of the posterior capsule using AquaLase is safe for corneal endothelial cells.

  19. Fully automated corneal endothelial morphometry of images captured by clinical specular microscopy

    NASA Astrophysics Data System (ADS)

    Bucht, Curry; Söderberg, Per; Manneberg, Göran

    2009-02-01

    The corneal endothelium serves as the posterior barrier of the cornea. Factors such as clarity and refractive properties of the cornea are in direct relationship to the quality of the endothelium. The endothelial cell density is considered the most important morphological factor. Morphometry of the corneal endothelium is presently done by semi-automated analysis of pictures captured by a Clinical Specular Microscope (CSM). Because of the occasional need of operator involvement, this process can be tedious, having a negative impact on sampling size. This study was dedicated to the development of fully automated analysis of images of the corneal endothelium, captured by CSM, using Fourier analysis. Software was developed in the mathematical programming language Matlab. Pictures of the corneal endothelium, captured by CSM, were read into the analysis software. The software automatically performed digital enhancement of the images. The digitally enhanced images of the corneal endothelium were transformed, using the fast Fourier transform (FFT). Tools were developed and applied for identification and analysis of relevant characteristics of the Fourier transformed images. The data obtained from each Fourier transformed image was used to calculate the mean cell density of its corresponding corneal endothelium. The calculation was based on well known diffraction theory. Results in form of estimated cell density of the corneal endothelium were obtained, using fully automated analysis software on images captured by CSM. The cell density obtained by the fully automated analysis was compared to the cell density obtained from classical, semi-automated analysis and a relatively large correlation was found.

  20. Eye bank prepared versus surgeon cut endothelial graft tissue for Descemet membrane endothelial keratoplasty: An observational study.

    PubMed

    Regnier, Marie; Auxenfans, Céline; Maucort-Boulch, Delphine; Marty, Anne-Sophie; Damour, Odile; Burillon, Carole; Kocaba, Viridiana

    2017-05-01

    The purpose of this article is to examine outcomes of Descemet membrane endothelial keratoplasty (DMEK) performed with cornea bank (CB) prestripped tissue and surgeon stripped tissue (SST).This retrospective study examined subjects who underwent DMEK with CB or surgeon prepared tissue for Fuchs endothelial corneal dystrophy. Best-corrected visual acuity (BCVA), corneal thickness, endothelial cell count (ECC), and complications were examined before and throughout a 6-month postoperative period.Eleven CB and 22 SST subjects were included. Six months after surgery, BCVA was 20/20 or better in 36.4% of CB and 22.7% of SST subjects (P = .43). Median logMAR BCVA was 0.10 (0.00-0.20, 20/25) in group CB and 0.10 (0.10-0.30, 20/25) in group SST. Median preoperative corneal thickness was 614.0 μm (577.5-662.0 μm) and 658.0 μm (606.0-689.0 μm) in CB and SST subjects, respectively (P = .37). Six months after surgery, median corneal thickness was lower in the CB group (571.0 μm [478.0-592.0 μm]), than in the SST group (576.0 μm [531.0-607.0 μm], P = .02). At 6 months, median ECC was 1500.0 cell/mm (1321.5-2049.0 cell/mm, 41% decrease) in group CB and 1403.0 cell/mm (972.5-2010.7 cell/mm, 46% decrease) in group SST (P = .70). Rebubbling was required in 5 CB (45.5%) and 15 SST (68.2%) subjects (P = .39).Fuchs' dystrophy patients have good anatomic and functional DMEK results. Similar outcomes and complication rates occurred with eye bank and surgeon prepared donor tissue.

  1. Development of Selective Lamellar Keratoplasty within an Asian Corneal Transplant Program: The Singapore Corneal Transplant Study (An American Ophthalmological Society Thesis)

    PubMed Central

    Tan, Donald; Ang, Marcus; Arundhati, Anshu; Khor, Wei-Boon

    2015-01-01

    Purpose: To evaluate outcomes of anterior lamellar keratoplasty (ALK) and endothelial keratoplasty (EK) within the Singapore Corneal Transplant Study (SCTS), with the hypothesis that both ALK and EK are able to provide equivalent or improved clinical outcomes, compared to penetrating keratoplasty (PK), and to determine changing trends globally with other international databases. Methods: Clinical data on all transplants performed was derived from our SCTS database, a prospective national keratoplasty registry, and clinical outcomes (graft survival, endothelial cell loss, complications, visual acuity) were compared between PK, ALK, and EK. Global trends on indications and forms of keratoplasty performed in 2011/2012 were obtained from national keratoplasty or eye banking registries, corneal/ophthalmological societies, national eye banks, and national ophthalmic institutions. Results: Global rates of EK surgery vary widely, from 52% (Sweden) to 0% (South Africa), with higher adoption by industrialized countries. ALK adoption rates similarly vary from 28.7% (China) to 1.0% (Philippines). SCTS data show high adoption rates in Singapore: EK 44% and ALK 28%. Our surgical modifications to big-bubble deep anterior lamellar keratoplasty (DALK) surgery resulted in visual outcomes matching PK, and a low conversion to PK of 2.1%, whereas our evolving approaches to donor insertion in Descemet’s stripping automated endothelial keratoplasty (DSAEK) show significant reduction in 1-year postoperative endothelial cell loss rates from 60% (folding), to 22% to 30% (Sheets Glide), to 15% (EndoGlide inserter). Conclusion: Improvements in various forms of ALK and EK surgery can lead to better visual outcomes, longer graft survival, and reduced complications, as compared to PK. Global trends suggest adoption of these procedures at different rates. PMID:26755854

  2. Air Versus Sulfur Hexafluoride Gas Tamponade in Descemet Membrane Endothelial Keratoplasty: A Fellow Eye Comparison.

    PubMed

    von Marchtaler, Philipp V; Weller, Julia M; Kruse, Friedrich E; Tourtas, Theofilos

    2018-01-01

    To perform a fellow eye comparison of outcomes and complications when using air or sulfur hexafluoride (SF6) gas as a tamponade in Descemet membrane endothelial keratoplasty (DMEK). One hundred thirty-six eyes of 68 consecutive patients who underwent uneventful DMEK in both eyes for Fuchs endothelial corneal dystrophy were included in this retrospective study. Inclusion criteria were air tamponade (80% of the anterior chamber volume) in the first eye and 20% SF6 gas tamponade (80% of the anterior chamber volume) in the second eye; and same donor tissue culture condition in both eyes. All eyes received laser iridotomy on the day before DMEK. Main outcome measures included preoperative and postoperative best-corrected visual acuity, endothelial cell density, corneal volume, rebubbling rate, and rate of postoperative pupillary block caused by the air/gas bubble. Thirteen of 68 eyes (19.1%) with an air tamponade needed rebubbling compared with 4 of 68 eyes (5.9%) with an SF6 gas tamponade (P = 0.036). Postoperative pupillary block necessitating partial release of air/gas occurred in 1 eye (1.5%) with an air tamponade and 3 eyes (4.4%) with an SF6 gas tamponade (P = 0.301). There were no significant differences in preoperative and postoperative best-corrected visual acuity, endothelial cell density, and corneal volume within 3-month follow-up. Our results confirm the previously reported better graft adhesion when using an SF6 gas tamponade in DMEK without increased endothelial cell toxicity. The rate of pupillary block in eyes with an SF6 gas tamponade was comparable to that with an air tamponade. As a consequence, we recommend using SF6 gas as the tamponade in DMEK.

  3. Outcomes of cataract surgery in eyes with a low corneal endothelial cell density.

    PubMed

    Yamazoe, Katsuya; Yamaguchi, Takefumi; Hotta, Kazuki; Satake, Yoshiyuki; Konomi, Kenji; Den, Seika; Shimazaki, Jun

    2011-12-01

    To evaluate the surgical outcomes of cataract surgery in eyes with a low preoperative corneal endothelial cell density (ECD) and analyze factors affecting the prognosis. Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan. Noncomparative case series. Eyes with a preoperative ECD of less than 1000 cells/mm(2) that had cataract surgery between 2006 and 2010 were identified. Standard phacoemulsification with intraocular lenses was performed using the soft-shell technique. The rate of endothelial cell loss, incidence of bullous keratopathy, and risk factors were retrospectively assessed. Sixty-one eyes (53 patients) with a low preoperative ECD were identified. Preoperative diagnoses or factors regarded as causing endothelial cell loss included Fuchs dystrophy (20 eyes), laser iridotomy (16 eyes), keratoplasty (10 eyes), traumatic injury (3 eyes), trabeculectomy (3 eyes), corneal endotheliitis (2 eyes), and other (7 eyes). The corrected distance visual acuity improved from 0.59 ± 0.49 logMAR preoperatively to 0.32 ± 0.48 logMAR postoperatively (P<.001). The mean ECD was 693 ± 172 cells/mm(2) and 611 ± 203 cells/mm(2), respectively (P=.001). The mean rate of endothelial cell loss was 11.5% ± 23.4%. Greater ECD loss was associated with a shorter axial length (AL) (<23.0 mm) and diabetes mellitus. Bullous keratopathy developed in 9 eyes (14.8%) and was associated with posterior capsule rupture. The results suggest that modern techniques for cataract surgery provide excellent visual rehabilitation in many patients with a low preoperative ECD. Shorter AL, diabetes mellitus, and posterior capsule rupture were risk factors for greater ECD loss and bullous keratopathy. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Genome-wide association study identifies three novel loci in Fuchs endothelial corneal dystrophy

    PubMed Central

    Afshari, Natalie A.; Igo, Robert P.; Morris, Nathan J.; Stambolian, Dwight; Sharma, Shiwani; Pulagam, V. Lakshmi; Dunn, Steven; Stamler, John F.; Truitt, Barbara J.; Rimmler, Jacqueline; Kuot, Abraham; Croasdale, Christopher R.; Qin, Xuejun; Burdon, Kathryn P.; Riazuddin, S. Amer; Mills, Richard; Klebe, Sonja; Minear, Mollie A.; Zhao, Jiagang; Balajonda, Elmer; Rosenwasser, George O.; Baratz, Keith H; Mootha, V. Vinod; Patel, Sanjay V.; Gregory, Simon G.; Bailey-Wilson, Joan E.; Price, Marianne O.; Price, Francis W.; Craig, Jamie E.; Fingert, John H.; Gottsch, John D.; Aldave, Anthony J.; Klintworth, Gordon K.; Lass, Jonathan H.; Li, Yi-Ju; Iyengar, Sudha K.

    2017-01-01

    The structure of the cornea is vital to its transparency, and dystrophies that disrupt corneal organization are highly heritable. To understand the genetic aetiology of Fuchs endothelial corneal dystrophy (FECD), the most prevalent corneal disorder requiring transplantation, we conducted a genome-wide association study (GWAS) on 1,404 FECD cases and 2,564 controls of European ancestry, followed by replication and meta-analysis, for a total of 2,075 cases and 3,342 controls. We identify three novel loci meeting genome-wide significance (P<5 × 10−8): KANK4 rs79742895, LAMC1 rs3768617 and LINC00970/ATP1B1 rs1200114. We also observe an overwhelming effect of the established TCF4 locus. Interestingly, we detect differential sex-specific association at LAMC1, with greater risk in women, and TCF4, with greater risk in men. Combining GWAS results with biological evidence we expand the knowledge of common FECD loci from one to four, and provide a deeper understanding of the underlying pathogenic basis of FECD. PMID:28358029

  5. Crystalline Subtype of Pre-Descemetic Corneal Dystrophy

    PubMed Central

    Dolz-Marco, Rosa; Gallego-Pinazo, Roberto; Pinazo-Durán, María Dolores; Díaz-Llopis, Manuel

    2014-01-01

    Purpose To report corneal findings in a familial case of the crystalline subtype of pre-Descemetic corneal dystrophy. Case Report A 19-year-old girl and her 44-year-old mother were found to have asymptomatic, bilateral, punctiform and multi-colored crystalline opacities across the whole posterior layer of the corneas. Endothelial specular microscopy revealed the presence of white round flecks located at different levels anterior to the endothelium. No systemic abnormalities or medications could be related to account for these findings. Conclusion To the best of our knowledge, this is the third familial report of this rare corneal disorder. Differential diagnosis may include Schnyder corneal dystrophy, cystinosis, Bietti´s dystrophy and monoclonal gammopathy. PMID:25279130

  6. A Cell Culture Approach to Optimized Human Corneal Endothelial Cell Function

    PubMed Central

    Bartakova, Alena; Kuzmenko, Olga; Alvarez-Delfin, Karen; Kunzevitzky, Noelia J.; Goldberg, Jeffrey L.

    2018-01-01

    Purpose Cell-based therapies to replace corneal endothelium depend on culture methods to optimize human corneal endothelial cell (HCEC) function and minimize endothelial-mesenchymal transition (EnMT). Here we explore contribution of low-mitogenic media on stabilization of phenotypes in vitro that mimic those of HCECs in vivo. Methods HCECs were isolated from cadaveric donor corneas and expanded in vitro, comparing continuous presence of exogenous growth factors (“proliferative media”) to media without those factors (“stabilizing media”). Identity based on canonical morphology and expression of surface marker CD56, and function based on formation of tight junction barriers measured by trans-endothelial electrical resistance assays (TEER) were assessed. Results Primary HCECs cultured in proliferative media underwent EnMT after three to four passages, becoming increasingly fibroblastic. Stabilizing the cells before each passage by switching them to a media low in mitogenic growth factors and serum preserved canonical morphology and yielded a higher number of cells. HCECs cultured in stabilizing media increased both expression of the identity marker CD56 and also tight junction monolayer integrity compared to cells cultured without stabilization. Conclusions HCECs isolated from donor corneas and expanded in vitro with a low-mitogenic media stabilizing step before each passage demonstrate more canonical structural and functional features and defer EnMT, increasing the number of passages and total canonical cell yield. This approach may facilitate development of HCEC-based cell therapies. PMID:29625488

  7. Eye-bank Preparation of Endothelial Tissue

    PubMed Central

    Boynton, Grace E.; Woodward, Maria A.

    2014-01-01

    Purpose of review Eyebank preparation of endothelial tissue for keratoplasty continues to evolve. While eye bank personnel have become comfortable and competent at Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) tissue preparation and tissue transport, optimization of preparation methods continues. Surgeons and eye bank personnel should be up to date on the research in the field. As surgeons transition to Descemet Membrane Endothelial Keratoplasty (DMEK), eye banks have risen to the challenge of preparing tissue. Eye banks are refining their DMEK preparation and transport techniques Recent findings This article covers refinements to DSAEK tissue preparation, innovations to prepare DMEK tissue, and nuances to improve donor cornea tissue quality. Summary As eye bank supplied corneal tissue is the main source of tissue for many corneal surgeons, it is critical to stay informed about tissue handling and preparation. Ultimately the surgeon is responsible for the transplantation, so involvement of clinicians in eye banking practices and advocacy for pursuing meaningful research in this area will benefit clinical patient outcomes. PMID:24837574

  8. Corneal endothelial autocrine trophic factor VIP in a mechanism-based strategy to enhance human donor cornea preservation for transplantation.

    PubMed

    Koh, Shay-Whey Margaret

    2012-02-01

    Vasoactive intestinal peptide (VIP) and ciliary neurotrophic factor (CNTF) are identified as autocrines of human corneal endothelial (CE) cells working in concert to maintain the differentiated state and promote the survival of the corneal endothelium. From VIP gene knockdown study, endogenous VIP is shown to maintain the level of the differentiation marker, the adhesion molecule N-cadherin, CE cell size, shape, and retention, in situ in the human donor corneoscleral explants. Exogenous VIP protects the corneal endothelium against the killing effect of oxidative stress, in part by upholding ATP levels in CE cells dying of oxidative stress-induced injury, allowing them to die of an apoptotic death instead of an acute necrotic one. The switch from the acute necrosis to the programmed cell death (apoptosis) may have allowed the injured CE cell to be rescued by the VIP-upregulated pathways, including those of Bcl-2 and N-cadherin, and resulted in long-term CE cell survival. The endogenous VIP in CE cells is upregulated by CNTF, which is released by CE cells surviving the oxidative stress. The CNTF receptor (CNTFRα) is expressed in CE cells in human donor corneoscleral explant and gradually becomes lost during corneal storage. VIP treatment (10(-8) M, 37 °C, 30 min) prior to storage of freshly dissected human donor corneoscleral explants increases their CE cell CNTFRα level and responsiveness to CNTF in upregulating the gap junctional protein connexin-43 expression. VIP treatment of both fresh and preserved corneoscleral explants reduces CE damage in the corneoscleral explants and in the corneal buttons trephined from them. CE cell loss is a critical risk factor in corneal graft failure at any time in the life of the graft, which can be as late as 5-10 years after an initially successful transplant. A new procedure, Descemet's stripping automated endothelial keratoplasty (DSAEK), which is superior to the traditional full thickness transplantation in many aspects, nevertheless subjects the corneal endothelium to extensive mechanical forces, resulting in even more pronounced CE cell loss than the traditional technique. Whereas it is known that cells transduce mechanical stress through N-cadherin, stimulation of the N-cadherin pathway increases the anti-apoptotic protein Bcl-2 expression. Since N-cadherin and Bcl-2 in the corneal endothelium are both upregulated by VIP, we aim to strengthen the CE sheet by VIP treatments of the corneoscleral explants for full thickness traditional corneal transplantation and pre-cut corneas for DSAEK. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Corneal endothelium in xeroderma pigmentosum: clinical specular microscopy study.

    PubMed

    Mohamed, Ashik; Peguda, Rajini; Ramappa, Muralidhar; Ali, Mohammad Javed; Chaurasia, Sunita

    2016-06-01

    Xeroderma pigmentosum is a condition caused due to a defective DNA repair mechanism when exposed to ultraviolet radiation. Many of the patients with this disorder develop severely oedematous cornea with varying degrees of anterior corneal haze, which necessitates a full-thickness keratoplasty or selective endothelial keratoplasty. Presence of corneal oedema suggests that these patients have a dysfunctional endothelium. The purpose of this study is to evaluate the corneal endothelium in the patients with xeroderma pigmentosum when clinical specular microscopy was feasible. Thirteen patients with classic skin changes of xeroderma pigmentosum were included in the study conducted during January 2010-December 2012. An age-matched group of 13 volunteers were included as controls who were emmetropes without any history of ocular or systemic illness. Corneal endothelium was assessed using specular microscopy from the central clear area of cornea. The mean age of the patients with xeroderma pigmentosum was 16.6±7.2 years and that of the controls was 17.4±6.9 years (p=0.78). The number of analysed cells and endothelial cell density were significantly higher in controls (p<0.001), whereas the average cell area, coefficient of variation of cell area and maximum cell area were significantly higher in xeroderma pigmentosum (p≤0.007). The specular microscopic findings in patients with xeroderma pigmentosum are suggestive of an accelerated endothelial cell loss. It is pertinent that the treating physicians must be involved in emphasising proper ocular protection from ultraviolet radiation to prevent avoidable blindness from xeroderma pigmentosum. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Sustainability of Routine Notification and Request legislation on eye bank tissue supply and corneal transplantation wait times in Canada.

    PubMed

    Lee, Kenneth; Boimer, Corey; Hershenfeld, Samantha; Sharpen, Linda; Slomovic, Allan R

    2011-10-01

    To assess whether provinces with Routine Notification and Request (RNR) legislation have sustained increases in corneal tissue supply and decreases in wait times for corneal transplantation surgery. Cross-sectional survey of Canadian corneal transplant (CT) surgeons and eye banks. Canadian CT surgeons and representatives from the 10 Canadian eye banks. Voluntary and anonymous surveys were distributed between July and October 2009. Eligible CT surgeons were defined as ophthalmologists who practice in Canada; currently perform Penetrating keratoplasty (PKP), Deep anterior lamellar keratoplasty (DALK), Deep lamellar endothelial keratoplasty (DLEK), Descemet stripping endothelial keratoplasty (DSEK), or Descemet membrane endothelial keratoplasty (DMEK); and have obtained tissues from a Canadian eye bank. From 2006 to 2009, for provinces with RNR legislation and where data are available, mean wait times from date of diagnosis to date of CT surgery have increased: in Ontario, from 31 ± 34 weeks to 36 ± 27 weeks; in British Columbia, from 39 ± 20 weeks to 42 ± 35 weeks; in Manitoba, from 32 ± 23 weeks to 49 ± 36 weeks. In addition, the amount of corneal tissue in RNR provinces suitable for transplant, with the exception of British Columbia, has declined between 2006 and 2008: in Ontario, 1186 tissues to 999 tissues (16% decline); in Manitoba, 92 tissues to 83 tissues (10% decline); in New Brunswick, 129 tissues to 98 tissues (24% decline). Although initially effective, RNR legislation has not sustained an increase in corneal tissue availability nor has it shortened wait times in most provinces. Incorporation of community hospitals into the RNR catchment, improved enforcement, and continued education of hospital staff regarding the RNR process may be effective in making this legislation more sustainable in the long term. Copyright © 2011 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  11. Scleral fixation of foldable acrylic intraocular lenses in aphakic post-vitrectomy eyes

    PubMed Central

    Mutoh, Tetsuya; Matsumoto, Yukihiro; Chikuda, Makoto

    2011-01-01

    Purpose To evaluate the outcome for scleral fixation of a foldable acrylic intraocular lens (IOL) in aphakic post-pars plana vitrectomy eyes for vitreoretinal disease. Methods The medical records of 15 patients were reviewed. We evaluated such factors as the underlying vitreoretinal disease, preoperative expected refraction and postoperative actual refraction, best corrected visual acuity (BCVA), corneal endothelial cell density, and intraoperative and postoperative complications. Results The most common cause of underlying vitreoretinal disease was retinal detachment, which was found in 8 cases. The mean refractive error was −0.10 diopters (D). The mean minimum angle of resolution (logMAR) values of BCVA were 0.27 preoperatively and 0.14 postoperatively. The mean corneal endothelial cell density was 2400 cells/mm2 preoperatively and 2187 cells/mm2 postoperatively. No significant differences were observed in either the logMAR values of BCVA or the corneal endothelial cell density before and after surgery. No intraoperative complications occurred in any of the patients. Postoperative complications occurred in a total of 7 eyes, and the most severe complications comprised 4 cases of transient ocular hypertension. Conclusion The results for the scleral fixation of foldable acrylic IOLs were good in aphakic post-vitrectomy eyes. PMID:21311652

  12. Segmentation of corneal endothelium images using a U-Net-based convolutional neural network.

    PubMed

    Fabijańska, Anna

    2018-04-18

    Diagnostic information regarding the health status of the corneal endothelium may be obtained by analyzing the size and the shape of the endothelial cells in specular microscopy images. Prior to the analysis, the endothelial cells need to be extracted from the image. Up to today, this has been performed manually or semi-automatically. Several approaches to automatic segmentation of endothelial cells exist; however, none of them is perfect. Therefore this paper proposes to perform cell segmentation using a U-Net-based convolutional neural network. Particularly, the network is trained to discriminate pixels located at the borders between cells. The edge probability map outputted by the network is next binarized and skeletonized in order to obtain one-pixel wide edges. The proposed solution was tested on a dataset consisting of 30 corneal endothelial images presenting cells of different sizes, achieving an AUROC level of 0.92. The resulting DICE is on average equal to 0.86, which is a good result, regarding the thickness of the compared edges. The corresponding mean absolute percentage error of cell number is at the level of 4.5% which confirms the high accuracy of the proposed approach. The resulting cell edges are well aligned to the ground truths and require a limited number of manual corrections. This also results in accurate values of the cell morphometric parameters. The corresponding errors range from 5.2% for endothelial cell density, through 6.2% for cell hexagonality to 11.93% for the coefficient of variation of the cell size. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Assessing the Impact of Diabetes Mellitus on Donor Corneal Endothelial Cell Density.

    PubMed

    Liaboe, Chase A; Aldrich, Benjamin T; Carter, Pamela C; Skeie, Jessica M; Burckart, Kimberlee A; Schmidt, Gregory A; Reed, Cynthia R; Zimmerman, M Bridget; Greiner, Mark A

    2017-05-01

    To quantify changes in endothelial cell density (ECD) of donor corneal tissue in relation to the presence or absence of a medical history of diabetes mellitus diagnosis, treatment, and complications. A retrospective review was performed for all corneas collected at Iowa Lions Eye Bank between January 2012 and December 2015. For purposes of analysis, donor corneas were divided into 4 groups: nondiabetic, non-insulin-dependent diabetic, insulin-dependent diabetic without medical complications due to diabetes, and insulin-dependent diabetic with medical complications due to diabetes. ECD values (obtained through specular microscopy) and transplant suitability for endothelial transplantation (determined by the standard protocol of the eye bank) were compared among groups using linear mixed model analysis. In total, 4185 corneas from 2112 donors were included for analysis. Insulin-dependent diabetic samples with medical complications due to diabetes (N = 231 from 119 donors) showed lower ECD values compared with nondiabetic samples (-102 cells/mm, P = 0.049) and non-insulin-dependent diabetic samples (-117 cells/mm, P = 0.031). ECD values did not differ significantly among the remaining groups. The likelihood of suitability for endothelial transplantation did not differ among all 4 groups. Corneas from donors with insulin-dependent diabetes mellitus and medical complications resulting from the disease have lower mean ECD values compared with other donors. However, our analysis suggests that these corneas are equally likely to be included in the donor pool for corneal transplantation. Additional studies are needed to determine the mechanism(s) contributing to cell loss in donors with advanced diabetes and to assess associated endothelial cell functional impairment.

  14. Targeting Microvascular Pericytes in Angiogenic Vessels of Prostate Cancer

    DTIC Science & Technology

    2006-04-01

    Schlingemann RO. 2004. In vivo angiogenic phenotype of endothelial cells and pericytes induced by vascular endothelial growth factor -a. J Histochem Cytochem...R, McDonald DM. Age-related changes in vascular endothelial growth factor dependency and angiopoietin-1-induced plasti- city of adult blood vessels...hematopoietic progenitor cells and their progeny in vivo . We used the basic fibroblast growth factor (bFGF)- induced mouse corneal neovascularization

  15. Methods Development for the Isolation and Culture of Primary Corneal Endothelial Cells

    DTIC Science & Technology

    2017-02-01

    1989 Yue et al. described methods that reached a 59% success rate in supporting human CEC growth using corneal tissue obtained from donors over 20...delayed-onset mustard gas keratitis: report of 48 patients and review of literature. Ophthalmology 2005; 112(4): 617-25. 6. Kadar T, Dachir S, Cohen L...toxicity following corneal exposure to sulfur mustard vapor. Invest Ophthalmol Vis Sci 2013; 54(10): 6735-44. 9. Kadar T, Cohen M, Cohen L, et al

  16. Nitrogen Mustard-Induced Corneal Injury Involves DNA Damage and Pathways Related to Inflammation, Epithelial-Stromal Separation, and Neovascularization.

    PubMed

    Goswami, Dinesh G; Tewari-Singh, Neera; Dhar, Deepanshi; Kumar, Dileep; Agarwal, Chapla; Ammar, David A; Kant, Rama; Enzenauer, Robert W; Petrash, J Mark; Agarwal, Rajesh

    2016-02-01

    To evaluate the toxic effects and associated mechanisms in corneal tissue exposed to the vesicating agent, nitrogen mustard (NM), a bifunctional alkylating analog of the chemical warfare agent sulfur mustard. Toxic effects and associated mechanisms were examined in maximally affected corneal tissue using corneal cultures and human corneal epithelial (HCE) cells exposed to NM. Analysis of ex vivo rabbit corneas showed that NM exposure increased apoptotic cell death, epithelial thickness, epithelial-stromal separation, and levels of vascular endothelial growth factor, cyclooxygenase 2, and matrix metalloproteinase-9. In HCE cells, NM exposure resulted in a dose-dependent decrease in cell viability and proliferation, which was associated with DNA damage in terms of an increase in p53 ser15, total p53, and H2A.X ser139 levels. NM exposure also induced caspase-3 and poly ADP ribose polymerase cleavage, suggesting their involvement in NM-induced apoptotic death in the rabbit cornea and HCE cells. Similar to rabbit cornea, NM exposure caused an increase in cyclooxygenase 2, matrix metalloproteinase-9, and vascular endothelial growth factor levels in HCE cells, indicating a role of these molecules and related pathways in NM-induced corneal inflammation, epithelial-stromal separation, and neovascularization. NM exposure also induced activation of activator protein 1 transcription factor proteins and upstream signaling pathways including mitogen-activated protein kinases and Akt protein kinase, suggesting that these could be key factors involved in NM-induced corneal injury. Results from this study provide insight into the molecular targets and pathways that could be involved in NM-induced corneal injuries laying the background for further investigation of these pathways in vesicant-induced ocular injuries, which could be helpful in the development of targeted therapies.

  17. [Effect of donor graft characteristics on clinical outcomes in Descemet stripping automated endothelial keratoplasty (DSAEK)].

    PubMed

    Ho Wang Yin, G; Sampo, M; Soare, S; Hoffart, L

    2017-01-01

    The purpose of our study was to evaluate the progression of lamellar corneal grafts after endothelial keratoplasty by Descemet stripping automated endothelial keratoplasty (DSAEK) and the effect of their characteristics on the clinical and functional results. This was a prospective study in which 74 patients who had undergone endothelial keratoplasty by DSAEK were included. The corneal grafts were obtained from a French tissue bank and were delivered in a preservation medium containing a deturgescent agent (Corneajet ® or Stemalpha 3 ® ). Pachymetry of the corneal graft was measured ex vivo by ultrasonic pachymetry prior to dissection, then after the 1st or 2 nd cut as necessary. Corrected visual acuity in logMAR, total graft pachymetry, measured by anterior segment OCT (Spectralis ® HRA+SDOCT, Heidelberg engineering, Inc., Heidelberg, Germany) and corneal density (Pentacam ® , Oculus, Inc., Wetzlar, Germany) were obtained for each patient preoperatively, at D5, M1, M3, M6, M9 and M12. Overall, 74 corneal grafts, from donors of mean age 69.7±13.3 years (37 to 92 years) were transplanted into 67 patients aged 70.3±12.1 years. Predissection pachymetry was statistically significantly thicker in the case of short deturgescence time (r=-0.383, P=0.001). For the same deturgescence time, predissection pachymetry was statistically significantly thicker in the Stemalpha 3 ® medium (691±89μm for Corneajet ® vs. 760±100μm for Stemalpha 3 ® , P=0.01), with the same final pachymetry (168±31μm vs. 166±25μm, P=0.833). Graft pachymetry and total corneal pachymetry decreased significantly between the preoperative measurement and M12 (168±29μm vs. 92±57μm, P=0.0008 et 665±124μm vs. 566±73μm, P=0.027 respectively). Preoperative endothelial cell density (2938±418 cells/mm 2 ) did not correlate with postoperative visual acuity. There was a positive correlation between visual acuity at D5 and donor age (r=0.3, P=0.04). Postoperative visual acuity correlated positively with preoperative visual acuity (P<0.05). Corneal densitometry was statically higher than normal postoperative densitometry. Corneal density at M1 correlated positively with time since obtaining the donor tissue (r=0.373, P=0.043). There was no significant difference between the sub-groups of over or under 130μm. Seven patients experienced graft failure with no statistically significant graft risk factor. The preservation medium affects predissection pachymetry with no consequence on clinical results. In our study, preoperative visual acuity and donor age were correlated with visual acuity after DSAEK. Although donor age was associated with better visual acuity at D5, the other donor characteristics had no effect on clinical results. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. [Evaluation of corneal tissue by slit lamp and specular microscopy during the preservation period].

    PubMed

    Farias, Roberta Jansen de Mello; Kubokawa, Karen Miyuki; Schirmer, Maurício; Sousa, Luciene Barbosa de

    2007-01-01

    To analyze changes evaluation of corneal grafts by slit lamp and electron microscopy examination in order to ensure a donor cornea of good quality level for the patient. 203 corneas donated to the Sorocaba Eye Bank between September 2002 and February 2003 were prospectively evaluated. The evaluation was graded from 0 to 3 according to the following factors: exposure and epithelial damage, stromal opacity, Descemet folds, pleomorphism, polymegatism and guttata, endothelial snail track, edema, reflectivity. The data were correlated with time between death and preservation, endothelial cell count and donor's age. 203 corneas were evaluated. The mean age of donors was 55 years (dp= 14.8 years). The mean time between death and preservation was 9.1 h (minimum of 2 h and maximum of 25 h). Eighty-six corneas suffered worsening of evaluation, whereby 66.3% had less than 2,500 endothelial cell count and 59.3% presented time between death and preservation over 6 hours. The mean day of the grading change was the 5th. Corneal grafts from younger donors had significantly better evaluation than those of older donors. The mean time of the evaluation change was on the 5th day in 50% of the corneas, however, an expressive number of corneas suffered changes on the 6th, 7th and 8th day. Corneal graft preserved after 6 hours of death had a greater tendency to lower cell count and to decrease in evaluation grades.

  19. Corneal collagen crosslinking for corneal ectasia of post-LASIK: one-year results

    PubMed Central

    Li, Gang; Fan, Zheng-Jun; Peng, Xiu-Jun

    2012-01-01

    AIM To evaluate the efficacy and safety of corneal collagen crosslinking (CXL) to prevent the progression of post-laser in situ keratomileusis (LASIK) corneal ectasia. METHODS In a prospective, nonrandomized, single-centre study, CXL was performed in 20 eyes of 11 patients who had LASIK for myopic astigmatism and subsequently developed keratectasia.The procedure included instillation of 0.1% riboflavin-20% dextrane solution 30 minutes before UVA irradiation and every 5 minutes for an additional 30 minutes during irradiation. The eyes were evaluated preoperatively and at 1-, 3-, 6-, and 12-month intervals. The complete ophthalmologic examination comprised uncorrected visual acuity, best spectacle-corrected visual acuity, endothelial cell count, ultrasound pachymetry, corneal topography, and in vivo confocal microscopy. RESULTS CXL appeared to stabilise or partially reverse the progression of post-LASIK corneal ectasia without apparent complication in our cohort. UCVA and BCVA improvements were statistically significant(P<0.05) beyond 12 months after surgery (improvement of 0.07 and 0.13 logMAR at 1 year, respectively). Mean baseline flattest meridian keratometry and mean steepest meridian keratometry reduction (improvement of 2.00 and 1.50 diopters(D), respectively) were statistically significant (P<0.05) at 12 months postoperatively. At 1 year after CXL, mean endothelial cell count did not deteriorate. Mean thinnest cornea pachymetry increased significantly. CONCLUSION The results of the study showed a long-term stability of post-LASIK corneal ectasia after crosslinking without relevant side effects. It seems to be a safe and promising procedure to stop the progression of post-LASIK keratectasia, thereby avoiding or delaying keratoplasty. PMID:22762048

  20. Structural, Morphological, and Functional Correlates of Corneal Endothelial Toxicity Following Corneal Exposure to Sulfur Mustard Vapor

    DTIC Science & Technology

    2013-10-01

    fentanyl patch (25 lg/h) was placed anterior to the scapula. On the day of exposure, rabbits were anesthetized with an intramuscular administration of 15 mg...sterile saline to flush residual agent. Rabbits were returned to cages and provided food and water ad libitum. Fentanyl patches were replaced after 72

  1. Corneal edema after phacoemulsification

    PubMed Central

    Sharma, Namrata; Singhal, Deepali; Nair, Sreelakshmi P; Sahay, Pranita; Sreeshankar, SS; Maharana, Prafulla Kumar

    2017-01-01

    Phacoemulsification is the most commonly performed cataract surgery in this era. With all the recent advances in investigations and management of cataract through phacoemulsification, most of the patients are able to achieve excellent visual outcome. Corneal edema after phacoemulsification in the immediate postoperative period often leads to patient dissatisfaction and worsening of outcome. Delayed onset corneal edema often warrants endothelial keratoplasty. This review highlights the etiopathogenesis, risk factors, and management of corneal edema in the acute phase including descemet's membrane detachment (DMD) and toxic anterior segment syndrome. Various investigative modalities such as pachymetry, specular microscopy, anterior segment optical coherence tomography, and confocal microscopy have been discussed briefly. PMID:29208818

  2. Multifunctional ion transport properties of human SLC4A11: comparison of the SLC4A11-B and SLC4A11-C variants.

    PubMed

    Kao, Liyo; Azimov, Rustam; Shao, Xuesi M; Frausto, Ricardo F; Abuladze, Natalia; Newman, Debra; Aldave, Anthony J; Kurtz, Ira

    2016-11-01

    Congenital hereditary endothelial dystrophy (CHED), Harboyan syndrome (CHED with progressive sensorineural deafness), and potentially a subset of individuals with late-onset Fuchs' endothelial corneal dystrophy are caused by mutations in the SLC4A11 gene that results in corneal endothelial cell abnormalities. Originally classified as a borate transporter, the function of SLC4A11 as a transport protein remains poorly understood. Elucidating the transport function(s) of SLC4A11 is needed to better understand how its loss results in the aforementioned posterior corneal dystrophic disease processes. Quantitative PCR experiments demonstrated that, of the three known human NH 2 -terminal variants, SLC4A11-C is the major transcript expressed in human corneal endothelium. We studied the expression pattern of the three variants in mammalian HEK-293 cells and demonstrated that the SLC4A11-B and SLC4A11-C variants are plasma membrane proteins, whereas SLC4A11-A is localized intracellularly. SLC4A11-B and SLC4A11-C were shown to be multifunctional ion transporters capable of transporting H + equivalents in both a Na + -independent and Na + -coupled mode. In both transport modes, SLC4A11-C H + flux was significantly greater than SLC4A11-B. In the presence of ammonia, SLC4A11-B and SLC4A11-C generated inward currents that were comparable in magnitude. Chimera SLC4A11-C-NH 2 -terminus-SLC4A11-B experiments demonstrated that the SLC4A11-C NH 2 -terminus functions as an autoactivating domain, enhancing Na + -independent and Na + -coupled H + flux without significantly affecting the electrogenic NH 3 -H (n) + cotransport mode. All three modes of transport were significantly impaired in the presence of the CHED causing p.R109H (SLC4A11-C numbering) mutation. These complex ion transport properties need to be addressed in the context of corneal endothelial disease processes caused by mutations in SLC4A11. Copyright © 2016 the American Physiological Society.

  3. Femtosecond laser cutting of multiple thin corneal stromal lamellae for endothelial bioengineering.

    PubMed

    Bernard, Aurélien; He, Zhiguo; Forest, Fabien; Gauthier, Anne-Sophie; Peocʼh, Michel; Dumollard, Jean-Marc; Acquart, Sophie; Montard, Romain; Delbosc, Bernard; Gain, Philippe; Thuret, Gilles

    2015-02-01

    To assess the feasibility of cutting multiple thin stromal lamellae in human donor corneas using a commercial femtosecond laser (FSL) to provide cell carriers for future endothelial graft bioengineering. Eight edematous organ-cultured corneas not suitable for grafting for endothelial reasons were mounted on a Ziemer anterior chamber and cut with a Z6 FSL with 6 successive parallel cuts, from depth to surface. Target thickness of each lamella ranged from 100 to 150 μm depending on initial corneal thickness. Thickness was measured using anterior segment optical coherence tomography before and after cutting on mounted corneas, and on each stromal lamella after detachment. Scanning electron microscopy observation was performed on 4 lamellae and histological cross sections on 1 cornea before detachment. A median of 5 (minimum 3, maximum 7) lamellae was obtained per cornea. All lamellae still attached were the most posterior ones, suggesting that FSL was less efficient because of light scattering by edematous stroma. Cut precision and postdetachment swelling were correlated with anterior-posterior position within the cornea. Median lamella thickness was 127 μm (56-222 μm) before detachment and 196 μm (80-304 μm) after detachment. Surface state was consistent with previously reported FSL lamellar cuts during Descemet stripping automated endothelial keratoplasty. Up to 7 thin lamellae can be cut in stored corneas with an FSL. This method, once optimized primarily by using deswelled, more transparent corneas, could prove effective for recycling unsuitable donor corneas in corneal bioengineering processes.

  4. Corneal endothelial cell density after femtosecond thin-flap LASIK and PRK for myopia: a contralateral eye study.

    PubMed

    Smith, Ryan T; Waring, George O; Durrie, Daniel S; Stahl, Jason E; Thomas, Priscilla

    2009-12-01

    To compare the effect of femtosecond thinflap LASIK and photorefractive keratectomy (PRK) on postoperative endothelial cell density. In a prospective, randomized, contralateral, single-center clinical trial, 25 patients (mean age: 30+/-5 years [range: 21 to 38 years]) underwent PRK in one eye and thin-flap LASIK in the fellow eye for the correction of myopia using a wavefront-guided platform. The central corneal endothelial cell density was measured using the NIDEK Confoscan 4 preoperatively, and at 1 and 3 months postoperatively. Changes in endothelial cell density were analyzed over time between the two refractive techniques. In PRK, the average preoperative endothelial cell density was 3011+/-329 cells/mm(2), which decreased to 2951+/-327 cells/mm(2) at 1 month (P=.5736) and 2982+/-365 cells/mm(2) at 3 months (P=.6513). In thinflap LASIK, the average preoperative endothelial cell density was 2995+/-325 cells/mm(2), which decreased to 2977+/-358 cells/mm(2) at 1 month (P=.5756) and 2931+/-369 cells/mm(2) at 3 months (P=.4106). No statistically significant difference was found between the two groups at 1 (P=.7404) or 3 (P=.3208) months postoperatively. No statistically significant change was noted in endothelial cell density following either PRK or thin-flap LASIK for the treatment of myopia. Furthermore, no statistically significant difference was found between the two groups out to 3 months postoperatively, indicating that thin-flap LASIK is as safe as PRK with regards to endothelial health.

  5. Five-Year Graft Survival Comparing Descemet Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty.

    PubMed

    Ang, Marcus; Soh, Yuqiang; Htoon, Hla Myint; Mehta, Jodhbir S; Tan, Donald

    2016-08-01

    To compare 5-year graft survival after Descemet stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty (PK) in Asian eyes. Prospective, nested, cohort study. Consecutive patients who underwent DSAEK (423 eyes) or PK (405 eyes) for Fuchs' endothelial dystrophy (FED) or bullous keratopathy (BK). Clinical data and donor and recipient characteristics were recorded from our prospective cohort from the Singapore Corneal Transplant Registry. All surgeries were performed by the corneal surgeons at our center, which included cases performed or partially performed by corneal fellows in training under direct supervision. Five-year cumulative graft survival. Overall mean age was 67.8±9.8 years, and 50.1% of patients were men. There were no significant differences in age (P = 0.261) or gender (P = 0.78) between PK and DSAEK groups in our predominantly Chinese (76.6%) Asian cohort, with more BK compared with FED (68.1% vs. 31.9%; P < 0.001). Overall 5-year graft survival was superior for DSAEK compared with PK (79.4% vs. 66.5%; P < 0.001, log-rank test). Median 5-year percent endothelial cell density loss was significantly greater in PK compared with DSAEK (60.9% vs. 48.7%; P = 0.007). Cox regression analysis revealed that BK was a significant factor associated with graft failure (hazard ratio [HR], 3.30; 95% confidence interval [CI], 2.05-5.33; P < 0.001), and PK was more likely to fail compared with endothelial keratoplasty (HR, 1.61; 95% CI, 1.08-2.41; P = 0.02) adjusting for confounders such as recipient age, gender, and donor factors. Five-year cumulative incidence of complications such as graft rejection (P < 0.001), epitheliopathy (P < 0.001), suture-related corneal infections (P < 0.001), and wound dehiscence (P = 0.002) were greater in the PK group compared with the DSAEK group. In Asian eyes from the same study cohort with standardized surgical and postoperative regimes, 5-year graft survival was superior for DSAEK compared with PK in eyes with FED and BK. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Association of smoking and other risk factors with Fuchs' endothelial corneal dystrophy severity and corneal thickness.

    PubMed

    Zhang, Xiaolin; Igo, Robert P; Fondran, Jeremy; Mootha, V Vinod; Oliva, Matt; Hammersmith, Kristin; Sugar, Alan; Lass, Jonathan H; Iyengar, Sudha K

    2013-08-27

    We investigated effects of smoking and other risk factors on the development of advanced Fuchs' endothelial corneal dystrophy (FECD) and on central corneal thickness (CCT). Eyes from Caucasian probands, affected and unaffected family members, and unrelated controls matched for age from the FECD Genetics Multi-Center Study (n = 2044 subjects) were examined. Univariate and multivariate models, adjusted for family correlations, were used to determine the effect of smoking, sex, diabetes, and age on FECD case/control status and CCT. In a multivariate model, sex and smoking were associated significantly with advanced FECD (grades 4-6) development (P = 0.016 and P = 0.047, respectively). Female sex increased odds by 34%. Smoking increased odds by 30%. In a multivariate model, diabetes was associated with an increase of 9.1 μm in average CCT (P = 0.021). Female sex was associated significantly with a decrease in average CCT by 6.9 μm (P = 0.015). Smoking had no significant effect on CCT in any model. As shown previously, advanced FECD was associated with large increases in CCT (31.4-94.2 μm). Smoking was associated with an increased risk of advanced FECD and self-reported diabetes was associated with increased CCT. Further study of the impact of smoking and diabetes on FECD development and changes in corneal thickness is warranted.

  7. Corneal Collagen Crosslinking Combined with Phototherapeutic Keratectomy and Photorefractive Keratectomy for Corneal Ectasia after Laser in situ Keratomileusis.

    PubMed

    Zhu, Wei; Han, Yunfei; Cui, Changxia; Xu, Wenwen; Wang, Xuan; Dou, Xiaoxiao; Xu, Linlin; Xu, Yanyun; Mu, Guoying

    2018-01-01

    The aim of this study was to analyze the effects of corneal crosslinking (CXL) combined with phototherapeutic keratectomy (PTK) and photorefractive keratectomy (PRK) in halting the progression and improving the visual function of corneal ectasia after laser in situ keratomileusis (LASIK). PTK-PRK-CXL was performed on 14 eyes of 14 patients who developed corneal ectasia after LASIK. The visual acuity, spherical refraction and cylinder, corneal topography indices, thinnest corneal thickness (TCT), and endothelial cell count were evaluated at baseline and at 1, 3, 6, and 12 months postoperatively. The mean uncorrected visual acuity improved significantly from 0.64 ± 0.36 logMAR preoperatively to 0.19 ± 0.12 logMAR at 12 months of follow-up (p < 0.001), while the mean best corrected visual acuity improved from 0.21 ± 0.14 logMAR at baseline to 0.04 ± 0.10 logMAR at 12 months postoperatively (p < 0.001). A significant decrease was observed in Kmax and Kmean values from 52.51 ± 6.74 and 43.55 ± 3.37 D at baseline to 45.72 ± 5.18 (p < 0.001) and 40.60 ± 3.05 D (p < 0.001) at the 1-year follow-up. The mean TCT decreased significantly from 419.07 ± 36.56 µm before treatment to 320.93 ± 39.78 µm at 12 months of follow-up (p < 0.001), and there was no significant endothelial cell loss (p > 0.05) beyond 6 months after treatment. PTK-PRK-CXL is a promising procedure to halt the progression of post-LASIK keratectasia with significant visual quality improvement. © 2018 S. Karger AG, Basel.

  8. Changes in the cornea related to sickle cell disease: a pilot investigation.

    PubMed

    Coşkun, Mesut; İlhan, Özgür; İlhan, Nilüfer; Tuzcu, Esra Ayhan; Daglioğlu, Mutlu Cihan; Kahraman, Hilal; Elbeyli, Ahmet; Yarbağ, Abdulhekim; Helvaci, Mehmet Rami

    2015-01-01

    To investigate corneal structural changes (central corneal thickness, endothelial cell count, and cellular morphology) in patients with sickle cell disease (SCD). This prospective study included 56 patients with SCD and 50 age- and sex-matched healthy subjects without any eye disease aside from refractive errors. Endothelial cell density (ECD), percentage of hexagonality, and the coefficient of variation in cell size (CV) were measured using noncontact specular microscopy, and central corneal thickness (CCT) was measured by pachymetry. The mean CCT value was 509.6 ± 20.7 μm in the study group and 520.8 ± 23.6 μm in the control group. The mean ECD, CV, and percentage of hexagonality values in the study group were 2712 ± 335 cells/mm², 34.5 ± 5.3%, and 57.2 ± 6.6%, respectively, and 3030 ± 247 cells/mm², 31.6 ± 5.0%, and 60.4 ± 6.9% in the control group, respectively. Endothelial cell density (p = 0.001), CCT (p = 0.011), CV (p = 0.005), and percentage of hexagonality values (p = 0.018) were significantly different between the study and control groups. The results of the current study indicate that patients with SCD had considerable morphologic changes in the structure of the cornea when compared to healthy subjects.

  9. Development of Poly Lactic/Glycolic Acid (PLGA) Microspheres for Controlled Release of Rho-Associated Kinase Inhibitor.

    PubMed

    Koda, Sho; Okumura, Naoki; Kitano, Junji; Koizumi, Noriko; Tabata, Yasuhiko

    2017-01-01

    The purpose of this study was to investigate the feasibility of poly lactic/glycolic acid (PLGA) as a drug delivery carrier of Rho kinase (ROCK) inhibitor for the treatment of corneal endothelial disease. ROCK inhibitor Y-27632 and PLGA were dissolved in water with or without gelatin (W1), and a double emulsion [(W1/O)/W2] was formed with dichloromethane (O) and polyvinyl alcohol (W2). Drug release curve was obtained by evaluating the released Y-27632 by using high performance liquid chromatography. PLGA was injected into the anterior chamber or subconjunctiva in rabbit eyes, and ocular complication was evaluated by slitlamp microscope and histological analysis. Y-27632 incorporated PLGA microspheres with different molecular weights, and different composition ratios of lactic acid and glycolic acid were fabricated. A high molecular weight and low content of glycolic acid produced a slower and longer release. The Y-27632 released from PLGA microspheres significantly promoted the cell proliferation of cultured corneal endothelial cells. The injection of PLGA did not induce any evident eye complication. ROCK inhibitor-incorporated PLGA microspheres were fabricated, and the microspheres achieved the sustained release of ROCK inhibitor over 7-10 days in vitro. Our data should encourage researchers to use PLGA microspheres for treating corneal endothelial diseases.

  10. Cytotoxicity of lidocaine to human corneal endothelial cells in vitro.

    PubMed

    Yu, Hao-Ze; Li, Yi-Han; Wang, Rui-Xin; Zhou, Xin; Yu, Miao-Miao; Ge, Yuan; Zhao, Jun; Fan, Ting-Jun

    2014-04-01

    Lidocaine has been reported to induce apoptosis on rabbit corneal endothelial cells. However, the apoptotic effect and exact mechanism involved in cytotoxicity of lidocaine are not well-established in human corneal endothelial (HCE) cells. In this study, we investigated the apoptosis-inducing effect of lidocaine on HCE cells in vitro. After HCE cells were treated with lidocaine at concentrations of 0.15625-10.0 g/l, the morphology and ultrastructure of the cells were observed by inverted light microscope and transmission electron microscope (TEM). Cell viability was measured by MTT assay, and the apoptotic ratio was evaluated with flow cytometry and fluorescent microscopic counting after FITC-Annexin V/PI and AO/EB staining. DNA fragmentation was detected by electrophoresis, and the activation of caspases was evaluated by ELISA. In addition, changes in mitochondrial membrane potential were determined by JC-1 staining. Results suggest that lidocaine above 1.25 g/l reduced cellular viability and triggered apoptosis in HCE cells in a time- and dose-dependent manner. Diminishment of ΔΨm and the activation of caspases indicate that lidocaine-induced apoptosis was caspase dependent and may be related to mitochondrial pathway. © 2013 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  11. Effect of laser peripheral iridotomy using argon and neodymium-YAG lasers on corneal endothelial cell density: 7-year longitudinal evaluation.

    PubMed

    Ono, Takashi; Iida, Masaharu; Sakisaka, Toshihiro; Minami, Keiichiro; Miyata, Kazunori

    2018-03-01

    To evaluate the changes in corneal endothelial cell density (ECD) over a 7-year period after laser peripheral iridotomy (LPI) using argon and neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers. Retrospective case series. Eyes that underwent prophylactic LPI using argon and Nd:YAG lasers were followed up for 7 years. Central corneal endothelial cells were observed by use of noncontact specular microscopy preoperatively and at 1 and 7 years postoperatively. Changes in ECD and the associations between preoperative ECD and the total energy of the Nd:YAG laser were evaluated. Fifty-one eyes of 51 patients were followed up for 7 years. The ECD significantly decreased after LPI (P < 0.049), and the reduction rate at 1 year after the surgery (1.69 ± 4.80%, 95% CI: 0.34%-3.04%) was significantly higher than the annual reduction rates after 1 year (0.17 ± 0.85%/y, P = 0.036, 95% CI: -0.07% to 0.41%). No association was found between the preoperative ECD and the total laser energy. Long-term evaluation indicated that the reduction in ECD after argon-Nd:YAG laser LPI was present but small during the initial year and was negligible after 1 year.

  12. Lymphatic vessels correlate closely with inflammation index in alkali burned cornea.

    PubMed

    Yan, Hao; Qi, Chaoxiu; Ling, Shiqi; Li, Weihua; Liang, Linyi

    2010-08-01

    To study the relationship between corneal lymphangiogenesis and inflammation in alkali burned corneas. Rat corneal lymphatic and blood vessels were labeled and distinguished by whole mount immunofluorescence and 5'-nase-alkaline phosphatase (5'-NA-ALP) double enzyme-histochemistry. Then, lymphatic vessel areas (LVA) and lymphatic vessel counting (LVC) were examined. Corneal inflammation was evaluated by inflammation index (IF) grading, histopathology, electron microscope, and polymorphonuclear leukocyte (PMN) infiltration. The relationship between LVC, LVA, IF, and PMN was examined, respectively. In addition, corneal lymphatic vessels of eleven human alkali burned corneas were examined by lymphatic vessel endothelial receptor (LYVE-1) immunohistochemistry. Corneal lymphangiogenesis occurred on Day 3, reached the peak at the end of two weeks, and disappeared five weeks after alkaline burns. Both LVA and LVC were strongly and positively correlated with IF after corneal alkaline burns. However, the relationship between LVC and PMN, between LVA and PMN were significant but converse. Among eleven human alkali burned corneas, corneal lymphangiogenesis was present in three corneas. Corneal lymphagiogenesis develops after alkaline burns and correlates closely with corneal inflammation.

  13. A comprehensive analysis of eye bank-prepared posterior lamellar corneal tissue for use in endothelial keratoplasty.

    PubMed

    Kelliher, Clare; Engler, Christoph; Speck, Caroline; Ward, Don; Farazdaghi, Sameera; Jun, Albert S

    2009-10-01

    The purpose of this study was to assess eye bank-prepared corneal tissue with regards to the accuracy of postcut tissue thickness, endothelial cell loss, and rate of successful processing. Details of all 913 corneal tissues processed with an automated microkeratome for use in posterior lamellar transplantation, over a 1-year period, were obtained from a large eye bank. The number and success rate of all attempted cutting procedures were analyzed. The thickness of the corneal button obtained after cutting was compared with the graft thickness requested by the operating surgeon. Changes in endothelial cell density (ECD) during tissue processing were evaluated. The rate of successful tissue preparation increased over the time period examined, from 95% in the first quarter to 99.5% in the fourth quarter. Graft material was frequently slightly thicker than requested by the operating surgeon with 28.3% of tissues cut thicker than requested. Postcut ECD over the entire period increased by an average of 4.7% and was closely related to the starting ECD. There was a very high rate of successful tissue preparation (98.5%), and early failed attempts at tissue cutting were likely the result of the initial learning curve of the involved technicians. Practical considerations resulted in tissue being cut marginally thicker than requested; this is an issue about which the operating surgeon should be aware, because it may possibly influence tissue handling. The quality of the obtained material, as measured by ECD, was excellent, although the calculated ECD may be prone to measurement artifact.

  14. Prevention and treatment of corneal graft rejection: current practice patterns of the Cornea Society (2011).

    PubMed

    Kharod-Dholakia, Bhairavi; Randleman, J Bradley; Bromley, Jennifer G; Stulting, R Doyle

    2015-06-01

    To analyze current practice patterns in the prevention and treatment of corneal graft rejection for both penetrating keratoplasty (PK) and endothelial keratoplasty (EK) and to compare these patterns with previously reported practices. In 2011, an electronic survey was sent to 670 members of the Cornea Society worldwide addressing the routine postoperative management of corneal transplants at different time points, treatment of various manifestations of corneal graft rejection, and preferred surgical techniques. A total of 204 of 670 surveys (30%) were returned and evaluated. All respondents used topical corticosteroids for routine postoperative management and treatment of endothelial graft rejection. Prednisolone was the topical steroid of choice in all clinical scenarios, similar to previous surveys from 1989 to 2004. Use of subconjunctival and systemic steroids increased for many scenarios of probable and definite graft rejection. Routine use of prednisolone decreased by approximately 10% from previous surveys, whereas difluprednate was used in 13% of high-risk eyes during the first 6 months. Dexamethasone, fluorometholone, and loteprednol use remained stable. Adjunctive topical cyclosporine use increased significantly for PK and EK. EK was the preferred technique for endothelial dysfunction, whereas PK and deep anterior lamellar keratoplasty were both used for keratoconus and anterior scars. Most respondents (75%) felt that graft rejection occurs more frequently after PK than after EK. Prednisolone remains the treatment of choice for management and treatment of graft rejection; however, since the introduction of difluprednate, its use has declined slightly since the introduction of difluprednate. Despite perceived differences in rejection rates, there were no differences in prophylactic steroid treatment for PK and EK.

  15. Outcomes of Phacoemulsification Using Different Size of Clear Corneal Incision in Eyes with Previous Radial Keratotomy.

    PubMed

    Zhang, Jing Shang; Liu, Xue; Wang, Jin Da; Xiong, Ying; Li, Jing; Li, Xiao Xia; Zhao, Jing; You, Qi Sheng; Huang, Yao; Tsai, Frank; Baum, Larry; Jhanji, Vishal; Wan, Xiu Hua

    2016-01-01

    To evaluate visual outcomes and complications after phacoemulsification in eyes with cataract and previous radial keratotomy (RK) cuts using different sizes of clear corneal incisions. The study was a retrospective study. Thirty eyes with cataract and previous RK underwent phacoemulsification and intraocular lens (IOL) implantation. Among them 7 eyes had 8 RK cuts, 13 eyes had 12 RK cuts, and 10 eyes had 16 RK cuts. Phacoemulsification and IOL implantation were performed through a 2.0-3.2 mm clear corneal incision by a single surgeon. In the 8 RK cuts group, 3.2 mm clear corneal incisions were used in 4 eyes, and 3.0 mm clear corneal incisions were used in 3 eyes. In the 12 RK cuts group, 3.2 mm clear corneal incisions were used in 6 eyes, and 2.2 mm clear corneal incisions were used in 7 eyes. In the 16 RK cuts group, 3.2 mm clear corneal incisions were used in 5 eyes, and 2.0 mm clear corneal incisions were used in 5 eyes. Patients were followed up 1 day, 1 week, 1 month, 3 months, 6 months, 1 year, 2 years, and 3 years postoperatively and were examined for the dehiscence of RK cuts during or after the surgery, post-operative best-corrected visual acuity (BCVA), corneal astigmatism, corneal endothelial cell density and complications. Successful phacoemulsification with IOL implantation was performed in all eyes. No wound dehiscence was noted in any eyes with 8 or 12 RK cuts. Wound dehiscence was noted in 2 eyes with 16 RK cuts. The dehiscence of RK cuts was closed successfully by injecting an air bubble with or without viscoelastic agent into the anterior chamber at the end of surgery. During the follow-up, the cuts were well apposed in all eyes, and no new dehiscence of RK cuts was noted. At the last follow-up, mean BCVA (0.2 ± 0.18 logMAR) was better than preoperative BCVA(0.45±0.19 logMAR) (P < 0.001). There was no significant difference between the long-term preoperative and postoperative mean corneal astigmatism (P = 0.3). However, there was a significant reduction in postoperative corneal endothelial cell density (1866.5±773.9 / mm2 vs 2421.7±655.7 / mm2) (P < 0.001). Phacoemulsification and IOL implantation with clear corneal incisions in eyes with previous RK were associated with good surgical outcomes. Wound dehiscence was not specificaly related to the size of clear corneal incision during phacoemulsification in these eyes.

  16. An evaluation of image quality and accuracy of eye bank measurement of donor cornea endothelial cell density in the Specular Microscopy Ancillary Study.

    PubMed

    Lass, Jonathan H; Gal, Robin L; Ruedy, Katrina J; Benetz, Beth Ann; Beck, Roy W; Baratz, Keith H; Holland, Edward J; Kalajian, Andrea; Kollman, Craig; Manning, Francis J; Mannis, Mark J; McCoy, Kristen; Montoya, Monty; Stulting, Doyle; Xing, Dongyuan

    2005-03-01

    The Specular Microscopy Ancillary Study was designed to examine donor corneal endothelial specular image quality, compare the central endothelial cell density determined by eye banks with the endothelial cell density determined by a central specular microscopy reading center, and evaluate donor factors that may have an impact on specular image quality and endothelial cell density accuracy. Nonrandomized comparative trial. Endothelial specular images of donor corneas assigned in the Cornea Donor Study. Certified readers assessed donor image quality (analyzable from fair to excellent vs. unanalyzable) and determined the central endothelial cell density. Independent adjudication was performed if there was a difference in the quality of grading or if the endothelial cell density varied by > or =5.0% between readers. Average reading center-determined endothelial cell density was compared with the endothelial cell density determined by each eye bank. Evaluation of image quality and accuracy of endothelial cell density. Of 688 donor endothelial images submitted by 23 eye banks, 663 (96%) were analyzable (excellent, 40 [6%]; good, 302 [44%]; fair, 321 [47%]), and 25 (4%) were unanalyzable by reading center standards. In situ retrieval and greater epithelial exposure correlated with a higher image quality grading. The eye bank-determined endothelial cell density of 434 of the 663 (65%) analyzable images were within 10% of the endothelial cell density determined by the reading center, whereas 185 (28%) were more than 10% higher and 44 (7%) were more than 10% lower. Greater variation in endothelial cell density between the eye banks and the reading center was observed with shorter time of death to preservation, presence of an epithelial defect, folds in Descemet's membrane, lower image quality, and the use of fixed-frame or center method endothelial cell density analysis. Overall, donor endothelial specular image quality and accuracy of endothelial cell density determination were good. However, the data suggest that factors that may affect image quality and contribute to variation in interpretation of the endothelial cell density should be addressed, because the donor endothelial cell density is an important parameter for assessing long-term corneal graft survival.

  17. The New Zealand National Eye Bank study: trends in the acquisition and storage of corneal tissue over the decade 2000 to 2009.

    PubMed

    Cunningham, William J; Moffatt, S Louise; Brookes, Nigel H; Twohill, Helen C; Pendergrast, David G C; Stewart, Joanna M; McGhee, Charles N J

    2012-05-01

    To evaluate trends in the acquisition, storage, and utilization of donated corneal tissue in New Zealand, 2000 to 2009. The New Zealand National Eye Bank records were analyzed for the decade January 2000 to December 2009. Variables analyzed included donor demographics (age, sex, and ethnicity), donor source, donor cause of death, death-to-preservation interval (DPI), corneal storage time, tissue contamination, endothelial assessment, cornea suitability for transplantation, and corneal tissue utilization. A total of 1268 eye donors were identified during the 10-year period. Overall, 36% (n = 457) were female and 64% male (n = 813). Median donor age was 67 years, and 23% of donors were younger than 50 years (range, 5-90 years). There was a decrease in donor age over the decade (P = 0.006). The median DPI was 18.5 hours. No relationship was identified between cornea suitability for transplantation and DPI (P = 0.28) or donor gender (P = 0.54). There was a low microbial contamination rate (1%). Human immunodeficiency virus, hepatitis B, or hepatitis C serology was positive in 48 donors (4%). Overall, 90% of corneas were suitable for transplantation with a high utilization rate (88%). A novel association was identified between male sex and lower corneal endothelial cell density (P = 0.03). This New Zealand National Eye Bank analysis identified trends in the acquisition, storage, and utilization of donated corneal tissue throughout New Zealand over the past decade and provides valuable additional information to the international eye bank data.

  18. Function of the tryptophan metabolite, L-kynurenine, in human corneal endothelial cells

    PubMed Central

    Lahdou, Imad; Scheuerle, Alexander; Höftberger, Romana; Aboul-Enein, Fahmy

    2009-01-01

    Purpose Penetrating keratoplasty has been the mainstay for the treatment of blindness and is the most common form of tissue transplantation worldwide. Due to significant rates of rejection, treatment of immunological transplant reactions is of wide interest. Recently in a mouse model, the overexpression of indoeleamine 2,3 dioxigenase (IDO) was led to an extension in corneal allograft survival. L-kynurenine is a tryptophan metabolite, which may render activated T-cells apoptotic and therefore might modulate an allogenous transplant reaction. The function of L-kynurenine in the human cornea remains unclear. We analyzed the expression levels of IDO in human corneal endothelial cells (HCECs) and downstream tryptophan/kynurenine mechanisms in cell culture. Methods An immunological activation profile was determined in proliferation assays of monocytes from healthy donors. Reversed-phase high pressure liquid chromatography (HPLC), western blot, real time polymerase chain reaction (PCR), and microarray analyses were used. The expression of IDO and immunological infiltration of rejected human corneal allografts (n=12) were analyzed by immunohistochemistry. Results We found IDO and an associated tryptophan/kynurenine transporter protein exchange mechanism upregulated by inflammatory cytokines in HCECs. The inhibition of T-cell proliferation might depend on rapid delivery of the tryptophan metabolite, L-kynurenine, to the local corneal environment. Microarray analysis gives evidence that the large amino acid transporter 1 (LAT1) transporter protein is responsible for this mechanism. Conclusions Our data support that adequate levels of functional L-kynurenine might contribute to the maintenance of a relative immune privilege in the ocular anterior chamber, thereby contributing to the preservation of corneal allogeneic cells. PMID:19597571

  19. Effects of Microwave Radiation on Humans. Monkeys Exposed to 1.25 GHZ pulsed Microwaves

    DTIC Science & Technology

    1992-03-13

    matter. The entire retina was examined by indirect ophthalmoscopy. Photographic documentation included photomicrographs of the corneal endothelial cells...segment and retina appear normal. Photos of corneal endothelium pre and post irradiation demonstrated no change. The retinal photos also appeared normal...and photographic documentation. However, baseline fluorescein angiograms of the retina and iris were also included. It was determined that baseline

  20. In vivo laser scanning confocal microscopy of the cornea in patients with silicone oil tamponade after vitreoretinal surgery.

    PubMed

    Le, Qihua; Wang, Xin; Lv, Jiahua; Sun, Xinghuai; Xu, Jianjiang

    2012-08-01

    To evaluate the morphological changes in the cornea by in vivo laser scanning confocal microscopy (LSCM) in a large case series with silicone oil endotamponade after vitreoretinal surgery and to explore the value of LSCM in the early detection of silicone keratopathy (SK). Ninety-nine patients (99 eyes) with silicone oil endotamponade after vitreoretinal surgery were included in the current study. Slit-lamp examination and measurement of intraocular pressure (IOP) were performed first. Then the central corneas of the subjects' eyes were examined by in vivo LSCM. The analysis of images of each corneal layer was performed and the endothelial cellular density (ECD), endothelial cellular area (ECA), coefficient of variation of cell size (CoV), and percentage of hexagonal cells (PHC) were measured. Moreover, the total size of stromal deposits was measured, and the correlation between the size of deposits and the parameters of endothelial cells was analyzed. Clinically recognizable abnormalities involving the cornea were identified in only 12 eyes (12.1%) under slit-lamp biomicroscopy, whereas in vivo LSCM revealed morphological abnormalities in 40 eyes (40.4%). The manifestations of endothelial lesions varied from decreased cellular density, increased polymegathism and pleomorphism to hyperreflective silicone oil membrane or droplets adhering to the endothelium. Moreover, hyperreflective deposits with various shapes could be identified in both posterior and anterior stroma, along with the infiltration of Langerhans cells beneath the epithelium. The average ECD and PHC of eyes with corneal abnormalities were significantly lower than those of normal corneas, whereas the average ECA and CoV were significantly larger (all Ps < 0.001). The patients with corneal abnormalities were significantly older than those others (P = 0.003). The rate of pseudophakic and aphakic eyes having corneal abnormalities was significantly higher than that of phakic eyes (P = 0.045). Interestingly, the total size of stromal deposits had a significant negative correlation with ECD and PHC but a significant positive correlation with ECA and CoV (all Ps < 0.001). Further correlation analysis performed in groups divided according to the lens status showed similar results and even stronger correlations in aphakic and pseudophakic eyes, whereas no statistically significant correlations were found in phakic eyes. In vivo LSCM was a useful tool in the early detection of corneal abnormalities caused by silicone oil injection, including varying corneal endothelium lesions and stromal abnormalities. Pseudophakic or aphakic eyes, as well as those of older patients, should receive more attention because they are more inclined to develop silicone keratopathy.

  1. Propagation of human corneal endothelial cells: a novel dual media approach.

    PubMed

    Peh, Gary S L; Chng, Zhenzhi; Ang, Heng-Pei; Cheng, Terence Y D; Adnan, Khadijah; Seah, Xin-Yi; George, Benjamin L; Toh, Kah-Peng; Tan, Donald T; Yam, Gary H F; Colman, Alan; Mehta, Jodhbir S

    2015-01-01

    Corneal endothelium-associated corneal blindness is the most common indication for corneal transplantation. Restorative corneal transplant surgery is the only option to reverse the blindness, but a global shortage of donor material remains an issue. There are immense clinical interests in the development of alternative treatment strategies to alleviate current reliance on donor materials. For such endeavors, ex vivo propagation of human corneal endothelial cells (hCECs) is required, but current methodology lacks consistency, with expanded hCECs losing cellular morphology to a mesenchymal-like transformation. In this study, we describe a novel dual media culture approach for the in vitro expansion of primary hCECs. Initial characterization included analysis of growth dynamics of hCECs grown in either proliferative (M4) or maintenance (M5) medium. Subsequent comparisons were performed on isolated hCECs cultured in M4 alone against cells expanded using the dual media approach. Further characterizations were performed using immunocytochemistry, quantitative real-time PCR, and gene expression microarray. At the third passage, results showed that hCECs propagated using the dual media approach were homogeneous in appearance, retained their unique polygonal cellular morphology, and expressed higher levels of corneal endothelium-associated markers in comparison to hCECs cultured in M4 alone, which were heterogeneous and fibroblastic in appearance. Finally, for hCECs cultured using the dual media approach, global gene expression and pathway analysis between confluent hCECs before and after 7-day exposure to M5 exhibited differential gene expression associated predominately with cell proliferation and wound healing. These findings showed that the propagation of primary hCECs using the novel dual media approach presented in this study is a consistent method to obtain bona fide hCECs. This, in turn, will elicit greater confidence in facilitating downstream development of alternative corneal endothelium replacement using tissue-engineered graft materials or cell injection therapy.

  2. Comparative Confocal and Histopathological Study of Corneal Changes in Multiple Myeloma.

    PubMed

    Micali, Antonio; Roszkowska, Anna M; Postorino, Elisa I; Rania, Laura; Aragona, Emanuela; Wylegala, Edward; Nowinska, Anna; Ieni, Antonio; Calimeri, Sebastiano; Pisani, Antonina; Aragona, Pasquale; Puzzolo, Domenico

    2017-01-01

    Corneal opacities rarely occur in multiple myeloma (MM). Our study correlates the findings of in vivo confocal microscopy (IVCM), a useful diagnostic tool, with histopathological features of corneal opacities appearing in a patient with MM. Case report. A 53-year-old man developed corneal opacities in both eyes, more pronounced in the left eye. After IVCM examination, he underwent penetrating keratoplasty in the left eye, and the button was processed for light and electron microscopy and immunohistochemistry. The diagnosis of MM was made, as confirmed by the elevation of IgGk light chains. IVCM demonstrated hyperreflective areas at the epithelial level, hyperreflective keratocytes of dendritic and lamellar morphology in whole stroma, and hyperreflective endothelial cells. Histopathological examination disclosed many vacuoles in the epithelial cell cytoplasm and a homogenous granular material in the Bowman layer. In stroma, keratocytes of different shape and size, with vesicles laden with an abnormal material, were evident. In Descemet membrane, the posterior nonbanded zone had a honeycomb appearance because of the presence of many roundish spaces among wide-spaced collagen fibers. Endothelial cells demonstrated vesicles filled with a material of uneven electron density. Immunohistochemical analysis showed strong positivity for IgGk light chains in keratocytes and among stromal lamellae. This is the first study describing a correspondence between IVCM features and histopathological alterations observed in corneal opacities in MM. The results of this study improve the current understanding of the pictures obtained by IVCM studies.

  3. In vivo laser confocal microscopy after non-Descemet's stripping automated endothelial keratoplasty.

    PubMed

    Kobayashi, Akira; Yokogawa, Hideaki; Sugiyama, Kazuhisa

    2009-07-01

    To investigate in vivo corneal changes in patients with bullous keratopathy who underwent non-Descemet's stripping automated endothelial keratoplasty (nDSAEK) with the use of laser confocal microscopy. Single-center, prospective clinical study. Ten eyes (10 patients; 3 men and 7 women; mean age, 73.5+/-6.6 years [mean+/-standard deviation]) with bullous keratopathy were evaluated in this study. In vivo laser confocal microscopy was performed before and 1, 3, and 6 months after nDSAEK. Selected confocal images of corneal layers were evaluated qualitatively and quantitatively for degree of haze and density of deposits. Before surgery, the following were observed in all patients: corneal epithelial edema, subepithelial haze, keratocytes in a honeycomb pattern, and tiny needle-shaped materials in the stroma. After nDSAEK, subepithelial haze, donor-recipient interface haze, and interface particles were observed in all measurable cases; postoperative haze, interface particles, and needle-shaped materials decreased statistically significantly (P<0.05) over the course of follow-up. In addition, hyperreflective giant interface particles were observed after nDSAEK in all patients. In vivo laser confocal microscopy can identify subclinical corneal abnormalities after nDSAEK such as subepithelial haze, host-recipient interface haze, host stromal needle-shaped materials, and host-recipient interface particles with characteristic giant particles. Further studies with this technology in a large number of patients and long-term follow-up are needed to understand fully the long-term corneal stromal changes after nDSAEK.

  4. Cell Homogeneity Indispensable for Regenerative Medicine by Cultured Human Corneal Endothelial Cells.

    PubMed

    Hamuro, Junji; Toda, Munetoyo; Asada, Kazuko; Hiraga, Asako; Schlötzer-Schrehardt, Ursula; Montoya, Monty; Sotozono, Chie; Ueno, Morio; Kinoshita, Shigeru

    2016-09-01

    To identify the subpopulation (SP) among heterogeneous cultured human corneal endothelial cells (cHCECs) devoid of cell-state transition applicable for cell-based therapy. Subpopulation presence in cHCECs was confirmed via surface CD-marker expression level by flow cytometry. CD markers effective for distinguishing distinct SPs were selected by analyzing those on established cHCECs with a small cell area and high cell density. Contrasting features among three typical cHCEC SPs was confirmed by PCR array for extracellular matrix (ECM). Combined analysis of CD markers was performed to identify the SP (effector cells) applicable for therapy. ZO-1 and Na+/K+ ATPase, CD200, and HLA expression were compared among heterogeneous SPs. Flow cytometry analysis identified the effector cell expressing CD166+CD105-CD44-∼+/-CD26-CD24-, but CD200-, and the presence of other SPs with CD166+ CD105-CD44+++ (CD26 and CD24, either + or -) was confirmed. PCR array revealed three distinct ECM expression profiles. Some SPs expressed ZO-1 and Na+/K+ ATPase at comparable levels with effector cells, while only one SP expressed CD200, but not on effector cells. Human leukocyte antigen expression was most reduced in the effector SP. The proportion of effector cells (E-ratio) inversely paralleled donor age and decreased during prolonged culture passages. The presence of Rho-associated protein kinase (ROCK) inhibitor increased the E-ratio in cHCECs. The average area of effector cells was approximately 200∼220 μm2, and the density of cHCECs exceeded 2500 cells/mm2. A specified cultured effector cell population sharing the surface phenotypes with mature HCECs in corneal tissues may serve as an alternative to donor corneas for the treatment of corneal endothelial dysfunction.

  5. Evaluation of Time to Donor Lenticule Apposition Using Intraoperative Optical Coherence Tomography in Descemet Stripping Automated Endothelial Keratoplasty.

    PubMed

    Titiyal, Jeewan S; Kaur, Manpreet; Falera, Ruchita; Jose, Cijin P; Sharma, Namrata

    2016-04-01

    To evaluate the time to donor lenticule apposition in cases of Descemet stripping automated endothelial keratoplasty (DSAEK) using microscope-integrated intraoperative optical coherence tomography (iOCT). Thirty eyes of 27 patients planned to undergo Descemet stripping automated endothelial keratoplasty were enrolled in this prospective study. In group I (n = 10), continuous intracameral positive pressure was maintained for 8 minutes. In group II (n = 10) and group III (n = 10), external corneal massage was initiated simultaneously with positive intracameral air pressure. The external corneal massage was continued till complete resolution of interface fluid; the positive intracameral pressure was maintained for 8 minutes in group II and for 5 minutes in group III. The host-donor relationship was continuously monitored with the iOCT. The main outcome measure was time to complete donor lenticule apposition. In group I, the interface fluid persisted after 8 minutes of positive intracameral pressure in all eyes (10/10); hence an external corneal massage was required to achieve optimal donor adherence. In groups II and III, all eyes (20/20) had complete resolution of the interface fluid at the end of 3 minutes. In 100% of the eyes (30/30), the grafts were attached after anterior chamber decompression as seen on the iOCT. In all cases, the donor lenticules were adhered in the postoperative period. iOCT helps in understanding that the donor lenticule is well apposed within 1 to 3 minutes with the technique of simultaneous positive intracameral pressure and external corneal massage. This knowledge minimizes the waiting time for graft apposition and prevents prolonged intraocular pressure elevation.

  6. Successful transplantation of in vitro expanded human cadaver corneal endothelial precursor cells on to a cadaver bovine's eye using a nanocomposite gel sheet.

    PubMed

    Parikumar, Periyasamy; Haraguchi, Kazutoshi; Ohbayashi, Akira; Senthilkumar, Rajappa; Abraham, Samuel J K

    2014-05-01

    In vitro expansion of human corneal endothelial precursor (HCEP) cells has been reported via production of cell aggregated spheres. However, to translate this procedure in human patients warrants maintaining the position of the eyeballs facing down for 36 h, which is not feasible. In this study, we report a method using a nanocomposite (NC) gel sheet to accomplish the integration of HCEP cells to the endothelium of cadaver bovine's eyes. HCEP cells were isolated from the corneal endothelium of a cadaver human eye and then expanded using a thermoreversible gelation polymer (TGP) as reported earlier. For the study, three cadaver bovine eyes were used. The NC gel sheets were inserted into the bovine eyes', aligned and suture-fixed in position under the host endothelium. HCEP cells previously expanded in the TGP were harvested and injected using a 26-gauge syringe between the endothelium and the NC gel sheet. The eyes were left undisturbed for three hours following which the NC gel sheets were gently removed. The corneas were harvested and subjected to histopathological studies. Histopathological studies showed that all the three corneas used for NC gel sheet implantation showed the presence of engrafted HCEP cells, seen as multi-layered cells over the native endothelium of the bovine cornea. Examination of the NC gel sheets used for implantation showed that only very few corneal endothelial cells remained on the sheets amounting to what could be considered negligible. The use of the NC gel sheet makes HCEP cell transplantation feasible for human patients. Further in vitro basic studies followed by translational studies are necessary to bring this method for clinical application in appropriate indications.

  7. Corneal clouding in Alport syndrome.

    PubMed

    Herwig, Martina C; Eter, Nicole; Holz, Frank G; Loeffler, Karin U

    2011-03-01

    Alport syndrome is a hereditary basement membrane disease that typically involves the kidney, the cochlea, and the eyes. Characteristic ocular problems include posterior polymorphous corneal dystrophy, lenticonus, and dot-and-fleck retinopathy. A 48-year-old male patient with Alport syndrome presented with corneal and retinal changes. In 2003, he was diagnosed with posterior polymorphous corneal dystrophy and received a corneal transplant in his left eye in 2007 because of progressive deterioration in visual acuity. At this time, a lamellar macular hole was diagnosed in his right eye. The removed corneal button was examined by light and electron microscopy and by immunohistochemistry. Histology revealed not only endothelial changes but also a marked irregular thickening of the epithelial basement membrane and of Bowman layer. Alcian blue staining demonstrated an accumulation of mucopolysaccharides in the Bowman layer. The presented changes underline the great variation of ocular disorders related to Alport syndrome. To our knowledge, this is one of the first reports describing histologic corneal findings in Alport syndrome. Only a few cases with accumulation of mucopolysaccharides in the Bowman layer have been described previously, none of them being associated with Alport syndrome. Besides, anterior corneal alterations and corneal clouding seem to be uncommon in patients suffering from Alport syndrome.

  8. Descemet’s Stripping Automated Endothelial Keratoplasty Outcomes Compared with Penetrating Keratoplasty from the Cornea Donor Study

    PubMed Central

    Price, Marianne O.; Gorovoy, Mark; Benetz, Beth A.; Price, Francis W.; Menegay, Harry J.; Debanne, Sara M.; Lass, Jonathan H.

    2010-01-01

    Purpose To assess outcomes 1 year after Descemet’s stripping automated endothelial keratoplasty (DSAEK) in comparison with penetrating keratoplasty (PKP) from the Specular Microscopy Ancillary Study (SMAS) of the Cornea Donor Study. Design Multicenter, prospective, nonrandomized clinical trial. Participants A total of 173 subjects undergoing DSAEK for a moderate risk condition (principally Fuchs’ dystrophy or pseudophakic/aphakic corneal edema) compared with 410 subjects undergoing PKP from the SMAS who had clear grafts with at least 1 postoperative specular image within a 15-month follow-up period. Methods The DSAEK procedures were performed by 2 experienced surgeons per their individual techniques, using the same donor and similar recipient criteria as for the PKP procedures in the SMAS performed by 68 surgeons at 45 sites, with donors provided from 31 eye banks. Graft success and complications for the DSAEK group were assessed and compared with the SMAS group. Endothelial cell density (ECD) was determined from baseline donor, 6-month (range, 5–7 months), and 12-month (range, 9–15 months) postoperative central endothelial images by the same reading center used in the SMAS. Main Outcome Measures Endothelial cell density and graft survival at 1 year. Results Although the DSAEK recipient group criteria were similar to the PKP group, Fuchs’ dystrophy was more prevalent in the DSAEK group (85% vs. 64%) and pseudophakic corneal edema was less prevalent (13% vs. 32%, P<0.001). The regraft rate within 15 months was 2.3% (DSAEK group) and 1.3% (PKP group) (P = 0.50). Percent endothelial cell loss was 34±22% versus 11±20% (6 months) and 38±22% versus 20±23% (12 months) in the DSAEK and PKP groups, respectively (both P<0.001). Preoperative diagnosis affected endothelial cell loss over time; in the PKP group, the subjects with pseudophakic/aphakic corneal edema experienced significantly higher 12-month cell loss than the subjects with Fuchs’ dystrophy (28% vs. 16%, P = 0.01), whereas in the DSAEK group, the 12-month cell loss was comparable for the 2 diagnoses (41% vs. 37%, P = 0.59). Conclusions One year post-transplantation, overall graft success was comparable for DSAEK and PKP procedures and endothelial cell loss was higher with DSAEK. PMID:20031230

  9. Assessment of the reliability of human corneal endothelial cell-density estimates using a noncontact specular microscope.

    PubMed

    Doughty, M J; Müller, A; Zaman, M L

    2000-03-01

    We sought to determine the variance in endothelial cell density (ECD) estimates for human corneal endothelia. Noncontact specular micrographs were obtained from white subjects without any history of contact lens wear, or major eye disease or surgery; subjects were within four age groups (children, young adults, older adults, senior citizens). The endothelial image was scanned, and the areas from > or =75 cells measured from an overlay by planimetry. The cell-area values were used to calculate the ECD repeatedly so that the intra- and intersubject variation in an average ECD estimate could be made by using different numbers of cells (5, 10, 15, etc.). An average ECD of 3,519 cells/mm2 (range, 2,598-5,312 cells/mm2) was obtained of counts of 75 cells/ endothelium from individuals aged 6-83 years. Average ECD estimates in each age group were 4,124, 3,457, 3,360, and 3,113 cells/mm2, respectively. Analysis of intersubject variance revealed that ECD estimates would be expected to be no better than +/-10% if only 25 cells were measured per endothelium, but approach +/-2% if 75 cells are measured. In assessing the corneal endothelium by noncontact specular microscopy, cell count should be given, and this should be > or =75/ endothelium for an expected variance to be at a level close to that recommended for monitoring age-, stress-, or surgery-related changes.

  10. Changes in corneal endothelial cell density and the cumulative risk of corneal decompensation after Ahmed glaucoma valve implantation.

    PubMed

    Kim, Kyoung Nam; Lee, Sung Bok; Lee, Yeon Hee; Lee, Jong Joo; Lim, Hyung Bin; Kim, Chang-Sik

    2016-07-01

    To evaluate changes in the corneal endothelial cell density (ECD) and corneal decompensation following Ahmed glaucoma valve (AGV) implantation. This study was retrospective and observational case series. Patients with refractory glaucoma who underwent AGV implantation and were followed >5 years were consecutively enrolled. We reviewed the medical records, including the results of central corneal specular microscopy. Of the 127 enrolled patients, the annual change in ECD (%) was determined using linear regression for 72 eyes evaluated at least four times using serial specular microscopic examination and compared with 31 control eyes (fellow glaucomatous eyes under medical treatment). The main outcome measures were cumulative risk of corneal decompensation and differences in the ECD loss rates between subjects and controls. The mean follow-up after AGV implantation was 43.1 months. There were no cases of postoperative tube-corneal touch. The cumulative risk of corneal decompensation was 3.3%, 5 years after AGV implantation. There was a more rapid loss of ECD in the 72 subject eyes compared with the 31 controls (-7.0% and -0.1%/year, respectively; p<0.001). However, the rate of loss decreased over time and statistical significance compared with control eyes disappeared after 2 years postoperatively: -10.7% from baseline to 1 year (p<0.01), -7.0% from 1 year to 2 years (p=0.037), -4.2% from 2 years to 3 years (p=0.230) and -2.7% from 3 years to the final follow-up (p=0.111). In case of uncomplicated AGV implantation, the cumulative risk of corneal decompensation was 3.3%, 5 years after the operation. The ECD loss was statistically greater in eyes with AGV than in control eyes without AGV, but the difference was significant only up to 2 years post surgery. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Clinical, histopathological and immunohistochemical characterization of a novel equine ocular disorder: heterochromic iridocyclitis with secondary keratitis in adult horses.

    PubMed

    Pinto, Nelson I; McMullen, Richard J; Linder, Keith E; Cullen, John M; Gilger, Brian C

    2015-11-01

    To describe the clinical, histopathologic and immunohistochemical characteristics of an equine ocular inflammatory disease resulting in anterior uveitis and corneal endothelial inflammation associated with iris pigment dispersion and retrocorneal fibrous membrane (RFM) formation. Retrospective study. Sixteen horses with evidence of pigmented keratic precipitates (KPs), corneal edema, and/or iris depigmentation. Information collected from the medical records included signalment, clinical signs, prereferral treatment duration and response to therapy, ophthalmic examination findings, postreferral treatment, response to therapy, and outcome. Twenty-one eyes from 16 horses were affected. Age ranged between 9 and 25 years (Average 16.1 years). Blepharospasm, epiphora, and/or corneal opacification were the first clinical signs noted. At the time of referral pigmented KPs, corneal edema, iridal depigmentation, and retrocorneal membranes were commonly seen. Treatment included topical and/or systemic anti-inflammatories and antibiotics with variable response. Reduction or cessation of anti-inflammatory therapy resulted in worsening of clinical signs and disease progression. Eight eyes ultimately required enucleation. Histopathology changes include iridal pigment loss and dispersion, RFM formation, and keratitis. Variable degrees of lymphoplasmacytic inflammation were dominated by T-cells within the corneal stroma, RFM, iris, and ciliary body with occasional multinucleated giant cells. Heterochromic iridocyclitis with secondary keratitis (HIK) is characterized by uveal inflammation with pigment dispersion and suspected corneal endothelial dysfunction. Horses being treated for HIK require diligent and frequent follow-up examinations in combination with aggressive local immune suppression to control the disease. However, HIK may not respond to therapy and enucleation may ultimately be required to ensure the horse's comfort. © 2014 American College of Veterinary Ophthalmologists.

  12. Late onset of a persistent, deep stromal scarring after PRK and corneal cross-linking in a patient with forme fruste keratoconus.

    PubMed

    Güell, Jose L; Verdaguer, Paula; Elies, Daniel; Gris, Oscar; Manero, Felicidad

    2014-04-01

    To present a case of a late, deep stromal scar in a 22-year-old patient with forme fruste keratoconus who underwent combined corneal cross-linking and photorefractive keratectomy (PRK). Topography-guided corneal cross-linking combined with corneal PRK (without complications) was performed in both eyes with a delay of 2 weeks between each eye. At the 5-month postoperative examination of the right eye, a localized corneal haze was circumscribed to the posterior deep stroma, signifying a decrease of visual acuity. However, this improved partially and temporarily when treated with topical corticoids during 2 years of follow-up and then reoccurred, affecting the corrected distance visual acuity. To the authors' knowledge, this is the first documented, clinical case presenting a deep stromal affectation without endothelial decompensation and visual acuity affectation as a postoperative complication following topography-guided PRK and corneal cross-linking. Copyright 2014, SLACK Incorporated.

  13. Development of Cell Analysis Software for Cultivated Corneal Endothelial Cells.

    PubMed

    Okumura, Naoki; Ishida, Naoya; Kakutani, Kazuya; Hongo, Akane; Hiwa, Satoru; Hiroyasu, Tomoyuki; Koizumi, Noriko

    2017-11-01

    To develop analysis software for cultured human corneal endothelial cells (HCECs). Software was designed to recognize cell borders and to provide parameters such as cell density, coefficient of variation, and polygonality of cultured HCECs based on phase contrast images. Cultured HCECs with high or low cell density were incubated with Ca-free and Mg-free phosphate-buffered saline for 10 minutes to reveal the cell borders and were then analyzed with software (n = 50). Phase contrast images showed that cell borders were not distinctly outlined, but these borders became more distinctly outlined after phosphate-buffered saline treatment and were recognized by cell analysis software. The cell density value provided by software was similar to that obtained using manual cell counting by an experienced researcher. Morphometric parameters, such as the coefficient of variation and polygonality, were also produced by software, and these values were significantly correlated with cell density (Pearson correlation coefficients -0.62 and 0.63, respectively). The software described here provides morphometric information from phase contrast images, and it enables subjective and noninvasive quality assessment for tissue engineering therapy of the corneal endothelium.

  14. An in situ formed biodegradable hydrogel for reconstruction of the corneal endothelium.

    PubMed

    Liang, Ye; Liu, Wanshun; Han, Baoqin; Yang, Chaozhong; Ma, Qun; Song, Fulai; Bi, Qingqing

    2011-01-01

    Biodegradable hydrogels are important biomaterials for tissue engineering and drug delivery. For the purpose of corneal regenerative medicine, we describe an in situ formed hydrogel based on a water-soluble derivative of chitosan, hydroxypropyl chitosan (HPCTS), and sodium alginate dialdehyde (SAD). Periodate oxidized alginate rapidly cross-links HPCTS due to Schiff's base formation between the available aldehyde and amino groups. Hydrogel cytotoxicity, degradability and histocompatibility in vivo were examined. The potential of the composite hydrogel for corneal endothelium reconstruction was demonstrated by encapsulating corneal endothelial cells (CECs) to grow on Descemet's membranes. The results demonstrate that the composite hydrogel was both non-toxic and biodegradable and that CECs transplanted by the composite hydrogel could survive and retain normal morphology. These results provide an opportunity for corneal endothelium reconstruction based on tissue engineering by the in situ formed composite hydrogel. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Acidification of rabbit corneal endothelium during contact lens wear in vitro.

    PubMed

    Giasson, C; Bonanno, J A

    1995-04-01

    Contact lens wear causes significant epithelial and stromal acidosis. In this study, we tested whether lens wear can cause endothelial acidosis as well. Rabbit corneas were isolated and perfused in vitro. The endothelial intracellular pH (pHi) was measured with a pH sensitive fluorescent probe (BCECF). Three conditions were examined: 1) Polymethylmethacrylate (PMMA) and rigid gas-permeable (RGP) contact lens wear using a range of oxygen transmissibility (Dk/L) from 0 to 121, 2) epithelial hypoxia produced by exposure to oligomycin/sodium azide solution or epithelial perfusion with 100% N2 equilibrated Ringer's solution, and 3) epithelial exposure to Ringer's equilibrated with 5% CO2, balance air. PMMA and RGP contact lens wear acidified endothelial cells by 0.23 +/- 0.01 (n = 23) and 0.11 +/- 0.01 pH units (n = 23), respectively, within twenty min of lens insertion. Epithelial hypoxia, induced by sodium azide and oligomycin, reversibly acidified the endothelium by 0.04 +/- 0.01 pH units (n = 4). However, epithelial hypoxia induced by perfusion with 100% N2 equilibrated Ringer's did not have a significant effect on endothelial pHi. Introduction of 5% CO2 to the epithelium, acidified the endothelium by 0.15 +/- 0.02 pH units (n = 7) within 10 min. We conclude that contact lens wear can significantly acidify corneal endothelial cells. The endothelial pHi change is caused almost exclusively by a build up of CO2 behind the lens; hypoxia having very little contribution. As expected, RGP contact lenses induced less endothelial acidosis than PMMA controls.

  16. High-intensity corneal collagen crosslinking with riboflavin and UVA in rat cornea.

    PubMed

    Zhu, Yirui; Reinach, Peter S; Zhu, Hanlei; Tan, Qiufan; Zheng, Qinxiang; Qu, Jia; Chen, Wei

    2017-01-01

    Corneal collagen cross-linking (CXL) halts human corneal ectasias progression by increasing stromal mechanical stiffness. Although some reports describe that this procedure is effective in dealing with some infectious and immunologic corneal thinning diseases, there is a need for more animal models whose corneal thickness more closely resemble those occurring in these patients. To meet this need, we describe here high-intensity protocols that are safe and effective for obtaining CXL in rat corneas. Initially, a range of potentially effective UVA doses were evaluated based on their effectiveness in increasing tissue enzymatic resistance to dissolution. At UVA doses higher than a threshold level of 0.54 J/cm2, resistance to enzymatic digestion increased relative to that in non-irradiated corneas. Based on the theoretical threshold CXL dose, a CXL regimen was established in which the UVA tissue irradiance was 9 mW/cm2, which was delivered at doses of either 2.16, 2.7 or 3.24 J/cm2. Their dose dependent effects were evaluated on ocular surface morphological integrity, keratocyte apoptotic frequency, tissue thickness and endothelial cell layer density. Doses of 2.16 and 2.7 J/cm2 transiently decreased normal corneal transparency and increased thickness. These effects were fully reversed after 14 days. In contrast, 3.24 J/cm2 had more irreversible side effects. Three days after treatment, apoptotic frequency in the CXL-2.16 group was lower than that at higher doses. Endothelial cell losses remained evident only in the CXL-3.24 group at 42 days posttreatment. Stromal fiber thickening was evident in all the CXL-treated groups. We determined both the threshold UVA dose using the high-intensity CXL procedure and identified an effective dose range that provides optimal CXL with minimal transient side effects in the rat cornea. These results may help to provide insight into how to improve the CXL outcome in patients afflicted with a severe corneal thinning disease.

  17. Corneal curvature, pachymetry, and endothelial cell density in Marfan syndrome.

    PubMed

    Konradsen, Tiina R; Koivula, Annemari; Kugelberg, Maria; Zetterström, Charlotta

    2012-06-01

    To evaluate corneal curvature, pachymetry, and endothelial cell density (ECD) in Marfan syndrome (MFS). A case-control study in which K values, pachymetry, and ECD were compared in 39 MFS eyes and 40 control eyes matched for age and refraction was conducted. MFS eyes with lens subluxation also were compared with eyes without subluxation. The mean K(med) value in MFS eyes was lower than in the control eyes, 42.2 ± 1.9 versus 43.4 ± 1.4 dioptres (D), respectively (p = 0.02). Fifteen MFS eyes (38%) and three control eyes (8%) had K(med) values below 41.5 D (p = 0.0012). MFS eyes had generally more corneal astigmatism than control eyes, 1.1 ± 0.9 versus 0.8 ± 0.4 D (p = 0.035), and MFS eyes with lens subluxation had more corneal astigmatism than those without, 1.6 ± 1.1 versus 0.6 ± 0.3 D (p = 0.0002). Nine MFS eyes with corneal astigmatism exceeding 1.5 D also had a subluxated lens. No eyes had keratoconus. The mean pachymetry value was lower in MFS eyes compared to the controls, 485 ± 54.5 versus 514 ± 37.3 μm (p = 0.007); 24 MFS eyes (62%) and 10 control eyes (25%) had measurements below 500 μm (p = 0.01). The mean ECD values were similar in MFS and control eyes, 2815 ± 430 versus 2858 ± 458 cells/mm(2) (p = 0.66). The mean K value, pachymetry, and ECD values did not differ between MFS eyes with and without lens subluxation. Decreased K values and pachymetry could indicate MFS regardless of subluxation. High corneal astigmatism is associated with subluxation in MFS. Subluxation should be identified in MFS eyes with high corneal astigmatism. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  18. Astigmatism Correction With Toric Intraocular Lenses in Descemet Membrane Endothelial Keratoplasty Triple Procedures.

    PubMed

    Yokogawa, Hideaki; Sanchez, P James; Mayko, Zachary M; Straiko, Michael D; Terry, Mark A

    2017-03-01

    To report the clinical efficacy of astigmatism correction with toric intraocular lenses (IOLs) in patients undergoing the Descemet membrane endothelial keratoplasty (DMEK) triple procedure and to evaluate the accuracy of the correction. Fifteen eyes of 10 patients who received cataract extraction, toric IOL placement, and DMEK surgery for Fuchs corneal dystrophy and cataracts were evaluated. The cylinder power of toric IOLs was determined by an online toric calculator with keratoscopy measurements obtained using Scheimpflug corneal imaging. Prediction errors were assessed as a difference vector between the anticipated minus postoperative residual astigmatism. At 10.1 ± 4.9 months postoperatively, 8/13 (61.5%) of eyes achieved uncorrected distance visual acuity better than 20/40. Mean best spectacle-corrected distance visual acuity (logMAR) improved from 0.21 ± 0.15 preoperatively to 0.08 ± 0.12 postoperatively (P < 0.01). The magnitude of refractive astigmatism was also significantly decreased from 2.23 ± 1.10 D (range 0.75-4.25 D) preoperatively to 0.87 ± 0.75 D (range 0.00-3.00 D) postoperatively (P < 0.01). In 1 eye with rotational misalignment by 43 degrees, we found no improvement of astigmatism. The prediction error of astigmatism at the corneal plane was 0.77 ± 0.54 D (range 0.10-1.77 D). Four eyes with preoperative "with-the-rule" corneal astigmatism had postoperative "against-the-rule" refractive astigmatism. For patients with Fuchs corneal dystrophy and cataracts, use of toric IOLs might be a valuable option in triple DMEK surgery. Additionally, care should be taken to prevent excessive IOL rotation.

  19. Effect of Diabetes Mellitus and Metformin on Central Corneal Endothelial Cell Density in Eye Bank Eyes.

    PubMed

    Chocron, Isaac M; Rai, Dinesh K; Kwon, Ji-Won; Bernstein, Nicole; Hu, Jimmy; Heo, Moonseong; Lee, Jimmy K; Gore, Patrick K; McCartney, Mitchell D; Chuck, Roy S

    2018-05-04

    To determine whether metformin use and diabetes mellitus (DM) affect central corneal endothelial cell density (ECD) by examining an eye bank corneal donor database. The Lions Eye Institute corneal donor database, which consists of 38,318 corneal samples, was examined. Associations of ECD with metformin use and DM were tested by mixed effects linear models that account for correlations of outcomes between eyes within subjects adjusting for age, intraocular lens status, and glaucoma. Subjects (N = 17,056) with observed ECD counts for both eyes are included for analysis. Average donor age was 56.3 (SD = 15.0). ECD was not associated with metformin use (mean ± SE = 2592 ± 11.9 (N = 1014) versus nonuse [2592 ± 3.0 (N = 16,042), P = 0.302]; further analysis showed that ECD was not significantly associated with metformin use in patients with diabetes. However, metformin use was significantly associated with lower ECD among patients with glaucoma: [2658 ± 50.7 (N = 27) for use versus 2789 ± 19.0 (N = 164) for nonuse, P = 0.018]. The presence of DM was significantly associated with lower ECD 2581 ± 5.6 (N = 4766) for DM versus 2595 ± 3.4 (N = 12,290) for non-DM, P = 0.031). Lower ECD was associated with DM. Lower ECD was not associated with metformin use except in a subgroup of patients with glaucoma, in which subgroup analysis showed lower ECD. The differences in ECD observed were small and unlikely to affect the suitability for transplantation of donor corneas.

  20. Methods Development for the Isolation and Culture of Primary Corneal Endothelial Cells

    DTIC Science & Technology

    2017-02-01

    are collectively referred to as mustard gas keratopathy (MGK). Prevailing evidence suggests that late onset MGK may result from a deficit in corneal...and PBK is similar to that seen in mustard gas keratopathy (MGK).3,6,7 MGK can occur years after ocular sulfur mustard (SM) exposure. Treatment...component into the stage component such that the O-ring creates a liquid -tight seal. The final assembled device is shown in panel D. A primary

  1. [Effectivity and Safety of a Modified Tip Design in Torsional Phacoemulsification].

    PubMed

    Schmidt, Sabine; Hubich, Sophie; Vetter, Jan Markus; Wirbelauer, Christopher

    2018-02-16

    Torsional mode phacoemulsification results in more effective fragmentation of the nucleus due to a different movement of the phacotip. In this clinical study, we investigated the influence of a modified tip design and active fluidics on the efficacy of phacoemulsification and safety for the corneal endothelium. We conducted a prospective randomized 2 : 1 study in which 40 patients were operated on with the mini-flared Kelman Tip using the Infiniti ® System (group 1), and 20 patients were operated on with the Intrepid ® Balanced Tip and the Centurion ® System. We analyzed the intraoperative cumulative dissipated energy and also the density of the corneal endothelium measured with an endothelial microscope (CEM 530, Nidek) pre- and postoperatively. Both groups did not differ preoperatively in age, sex, axial length of the globe or corneal endothelium cell density nor cataract density (LOCS3). All surgeries were uneventful. The cumulative dissipated energy in group 1 (mini-flared Kelman tip, Infiniti System) was 38% higher than in group 2 (balanced tip, Centurion System; p < 0.05). The endothelial cell loss was 8% in group 1 and 10.3% in group 2 (p > 0.05). The cell size (polymegathism) increased in both groups significantly with + 37 µm in group 1 (p < 0.05) und + 54 µm in group 2 (p < 0.05). There was no statistically significant difference between both groups (p > 0.05). The number of hexagonal cells (pleomorphism) and corneal thickness did not differ in both groups either pre- nor postoperatively. Compared to torsional phacoemulsification with a mini-flared Kelman Tip and gravity fluidics, torsional phacoemulsification with a modified tip design and active fluidics is 38% more effective regarding the cumulative dissipated energy. Endothelial cell loss occurs to a similar extend using both systems. The postoperative changes in cell size (polymegathism), number of hexagonal cells (pleomorphism) and corneal thickness (pachymetry) were similar among both systems. We conclude, that the intraoperative stress on the endothelium is equivalent with both systems used. Georg Thieme Verlag KG Stuttgart · New York.

  2. The Favorable Effect of Mesenchymal Stem Cell Treatment on the Antioxidant Protective Mechanism in the Corneal Epithelium and Renewal of Corneal Optical Properties Changed after Alkali Burns.

    PubMed

    Cejka, Cestmir; Holan, Vladimir; Trosan, Peter; Zajicova, Alena; Javorkova, Eliska; Cejkova, Jitka

    2016-01-01

    The aim of this study was to examine whether mesenchymal stem cells (MSCs) and/or corneal limbal epithelial stem cells (LSCs) influence restoration of an antioxidant protective mechanism in the corneal epithelium and renewal of corneal optical properties changed after alkali burns. The injured rabbit corneas (with 0.25 N NaOH) were untreated or treated with nanofiber scaffolds free of stem cells, with nanofiber scaffolds seeded with bone marrow MSCs (BM-MSCs), with adipose tissue MSCs (Ad-MSCs), or with LSCs. On day 15 following the injury, after BM-MSCs or LSCs nanofiber treatment (less after Ad-MSCs treatment) the expression of antioxidant enzymes was restored in the regenerated corneal epithelium and the expressions of matrix metalloproteinase 9 (MMP9), inducible nitric oxide synthase (iNOS), α-smooth muscle actin (α-SMA), transforming growth factor-β1 (TGF-β1), and vascular endothelial factor (VEGF) were low. The central corneal thickness (taken as an index of corneal hydration) increased after the injury and returned to levels before the injury. In injured untreated corneas the epithelium was absent and numerous cells revealed the expressions of iNOS, MMP9, α-SMA, TGF-β1, and VEGF. In conclusion, stem cell treatment accelerated regeneration of the corneal epithelium, restored the antioxidant protective mechanism, and renewed corneal optical properties.

  3. The newest member of the VEGF family.

    PubMed

    Albuquerque, Romulo J C

    2013-05-16

    In this issue of Blood, Singh et al establish the existence of a new soluble isoform of vascular endothelial growth factor receptor 3 (sVEGFR-3), which is synthesized and secreted by corneal epithelial cells; they show that sVEGFR-3 modulates lymphangiogenesis by impounding vascular endothelial growth factor (VEGF) C and rendering it unable to activate its cognate receptors, thereby maintaining the natural alymphatic disposition of the cornea.

  4. Outcomes of Descemet Stripping Endothelial Keratoplasty Using Eye Bank-Prepared Preloaded Grafts.

    PubMed

    Palioura, Sotiria; Colby, Kathryn

    2017-01-01

    To evaluate the feasibility of Descemet stripping endothelial keratoplasty using grafts preloaded by an eye bank in a commercially available insertion device. In this retrospective case series, a series of 35 eyes in 34 consecutive patients who underwent Descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy or previously failed full-thickness grafts at a single tertiary care center from March 2013 to March 2014 was included. The donor tissue had undergone pre-lamellar dissection, trephination, and loading into EndoGlide Ultrathin inserters at the Lions Eye Institute for Transplant and Research (Tampa, FL) and was shipped overnight in Optisol GS to the surgeon (K.C.). Surgery was performed within 24 hours from tissue preparation and loading by the eye bank. Donor and recipient characteristics, endothelial cell density (ECD), best-corrected visual acuity, and central corneal thickness were recorded. The main outcome measures were intraoperative and postoperative complications and ECD loss at 3, 6, and 12 months. One primary graft failure (2.8%), 2 rebubblings (5.7%), and 1 graft rejection (2.8%) occurred. Mean preoperative donor ECD was 2821 ± 199 cells/mm. Six months postoperatively, the mean endothelial cell loss was 25.3% ± 17.2% (n = 32), which remained stable at 1 year (31.5% ± 17.9%, n = 32). Mean best-corrected visual acuity improved from 20/100 preoperatively to 20/25 at a mean follow-up of 1 year (n = 32). Mean central corneal thickness was reduced from 711 ± 110 μm to 638 ± 66 μm at the last follow-up visit. Donor graft tissue preloaded by an eye bank can be used successfully for endothelial keratoplasty. Preloading reduces intraoperative tissue manipulation.

  5. VRP09 Reduction of Corneal Scarring Following Blast and Burn Injuries to Cornea Using siRNAs Targeting TGFb and CTGF

    DTIC Science & Technology

    2012-10-01

    selective of all gene-targeted, oligonucleotide-based drug approaches (better than ribozymes, antisense oligonucleotides ( ASO ), or microRNAs).(4) We will...respect to a scrambled siRNA control. For the migration assay, a circular region in the middle of the well was removed using a gel removal solution...oligonucleotides, ASOs ) into rabbit corneal cells and found that technique was very effective in delivering ASOs into the stroma and even into the endothelial cell

  6. Evaluation of possible error sources in corneal endothelial morphometry with a semiautomated noncontact specular microscope.

    PubMed

    Doughty, Michael J

    2013-09-01

    To assess the corneal endothelium, particularly the polymegethism feature, using the Topcon SP-3000P specular microscope with newer center-dot software. Forty-eight healthy, normal weight, noncontact lens wearers of Asian ethnicity were assessed. Single endothelial images from each subject were processed with center-dot software, reevaluated after correction of obvious errors, and then by manual border marking and planimetry. Endothelial cell density based on average cell area and the coefficient of variation (COV) of cell area (polymegethism) were calculated. Error sources are associated with erroneous location of cell borders (usually creating larger or smaller "cells") or failure to assign cell borders to a marked cell. On the initial application of the center-dot software, the endothelial cell density values ranged from 1822 to 3244 cells per square millimeter (mean, 2644 cells/mm); this range was reduced (eg, 1955-3054 cells/mm; mean 2690 cells/mm on editing or in manual planimetry). The COV values ranged from 17% to 39% (mean, 27.5% ± 5.5%), with one third of the endothelia yielding COV values of greater than or equal to 30%. On editing or in manual planimetry, the COV values were reduced to between 17% and 29% (mean, 24.5% ± 3.2%; P < 0.001). In the use of a center-dot endothelial analysis program with cell border identification, it is likely that at least 1 set of editing steps is required to produce reasonable results.

  7. A sliding technique to load thin endothelial donor lamella onto Busin glide for Descemet-stripping automated endothelial keratoplasty

    PubMed Central

    Kobayashi, Akira; Yokogawa, Hideaki; Sugiyama, Kazuhisa

    2012-01-01

    We describe a modified technique for loading donor corneal endothelial lamella onto a Busin glide® without causing wrinkles, as part of the procedure of Descemet-stripping automated endothelial keratoplasty. Briefly, after punching out a composite of the donor-endothelial lamella and a microkeratome-dissected cap, several drops of dispersive ophthalmic viscosurgical device are placed onto the endothelial surface. The Busin glide surface is then wetted with several drops of balanced salt solution. After the composite is transferred onto the Busin glide, hydrodissection of the potential space between the donor-endothelial lamella and the microkeratome-dissected cap is carefully performed to enable smooth detachment of these two lamellae. Whereas simply dragging the donor-endothelial lamella directly onto the glide can cause wrinkling or folding of the donor lamella, this technique enables smooth detachment of the composite without wrinkle or fold formation, and results in less endothelial cell damage. PMID:22927732

  8. Changes in Corneal Endothelial Cell after Ahmed Glaucoma Valve Implantation and Trabeculectomy: 1-Year Follow-up.

    PubMed

    Kim, Min Su; Kim, Kyoung Nam; Kim, Chang-Sik

    2016-12-01

    To compare changes in corneal endothelial cell density (CECD) after Ahmed glaucoma valve (AGV) implantation and trabeculectomy. Changes in corneal endothelium in patients that underwent AGV implantation or trabeculectomy were prospectively evaluated. Corneal specular microscopy was performed at the central cornea using a non-contact specular microscope before surgery and 6 months and 12 months after surgery. The CECD, hexagonality of the endothelial cells, and the coefficient of variation of the cell areas were compared between the two groups. Forty eyes of 40 patients with AGV implantation and 28 eyes of 28 patients with trabeculectomy were studied. Intraocular pressure in the AGV implantation group was significantly higher than that in the trabeculectomy group ( p < 0.001), but there was no significant difference in other clinical variables between the two groups. In the AGV implantation group, the mean CECD significantly decreased by 9.4% at 6 months and 12.3% at 12 months compared with baseline values (both, p < 0.001), while it decreased by 1.9% at 6 months and 3.2% at 12 months in the trabeculectomy group ( p = 0.027 and p = 0.015, respectively). The changes at 6 months and 12 months in the AGV implantation group were significantly higher than those in the trabeculectomy group ( p = 0.030 and p = 0.027, respectively). In the AGV implantation group, there was a significant decrease in the CECD between baseline and 6 months and between 6 months and 12 months ( p < 0.001 and p = 0.005, respectively). However, in the trabeculectomy group, a significant decrease was observed only between baseline and 6 months ( p = 0.027). Both the AGV implantation group and the trabeculectomy group showed statistically significant decreases in the CECD 1 year after surgery. The decrease in CECD in the AVG implantation group was greater and persisted longer than that in the trabeculectomy group.

  9. Trends in the distribution of donor corneal tissue and indications for corneal transplantation: the New Zealand National Eye Bank Study 2000-2009.

    PubMed

    Cunningham, William J; Brookes, Nigel H; Twohill, Helen C; Moffatt, S Louise; Pendergrast, David G C; Stewart, Joanna M; McGhee, Charles N J

    2012-03-01

    To investigate the indications for corneal transplantation and the distribution of donor corneal tissue in New Zealand. Analysis of the prospective database of the New Zealand National Eye Bank. A total of 2205 corneal transplants were assessed. New Zealand National Eye Bank records were analysed for the decade 2000-2009. Variables analysed included donor corneal tissue distribution (including public and private sectors), indications for transplantation, donor corneal tissue recipient demographics (age and gender) and corneal transplantation type. An average of 220 corneal transplants were performed each year over the 10-year period (n=2205). The median recipient age was 45years (range 3 to 102years) and 54.0% of recipients were male. In total 71.8% of transplants were performed in the public health sector. Surgeons in the Auckland metropolitan area performed 47.2% of all corneal transplants. The most common indications for corneal transplantation were: keratoconus (41.1%), repeat transplant (17.0%), aphakic/pseudophakic bullous keratopathy (13.9%), corneal dystrophy (10.7%), keratitis (7.9%) and trauma (3.7%). Overall, penetrating keratoplasty accounted for 90.7% of all corneal transplants, however, during the latter half of the study there was a progressive shift in transplantation type, with deep anterior lamellar keratoplasty and Descemet's stripping endothelial keratoplasty combined accounting for 32.3% of all transplants in the final year of the study period. This New Zealand National Eye Bank study provides valuable data regarding the indications for corneal transplantation, transplant recipient demographics and changes in transplantation type in New Zealand over the past decade. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  10. Analyses of Factors Affecting Endothelial Cell Density in an Eye Bank Corneal Donor Database.

    PubMed

    Kwon, Ji Won; Cho, Kyong Jin; Kim, Hong Kyu; Lee, Jimmy K; Gore, Patrick K; McCartney, Mitchell D; Chuck, Roy S

    2016-09-01

    To analyze the factors affecting central corneal endothelial cell density (ECD) in an eye bank corneal donor database. The Lion's Eye Institute corneal donor database consisting of 18,665 donors (34,234 corneas) aged 20 years or older was analyzed. In particular, differences in the ECD based on age, sex, race, prior ocular surgery, a history of systemic diseases, and smoking were investigated. Furthermore, risk factors for donor cell count inadequacy (defined here as ECD less than 2000/mm) were identified. ECD decreased with age. Regarding race, the average ECD of African American donors was higher than those of white or Hispanic donors. A history of diabetes mellitus (DM) and ocular surgery were associated with a lower ECD. Donor medical history of hypertension, glaucoma, depression, dementia, Parkinson disease, hyper- or hypothyroidism, or smoking did not seem to affect the ECD. The risk factors for donor cell count inadequacy, based on binary logistic regression analyses were advanced age [65-74 years yielded an odds ratio of 17.8; confidence interval (CI), 10.6-29.8; P < 0.001; and 75-99 years yielded an odds ratio of 24.6 (CI, 14.5-41.61; P < 0.001) when compared with 20-34 years], cataract surgery (odds ratio, 4.3; CI, 4.0-4.8; P < 0.001), and DM (odds ratio, 1.2; CI, 1.1-1.3; P = 0.001). Age, race, ocular surgery (cataract and refractive), and DM seem to significantly affect donor corneal ECD. Of these variables, age, a history of cataract surgery, and DM were found to be the greatest risk factors for inadequate donor cell density (less than 2000/mm).

  11. Menadione-Induced DNA Damage Leads to Mitochondrial Dysfunction and Fragmentation During Rosette Formation in Fuchs Endothelial Corneal Dystrophy

    PubMed Central

    Halilovic, Adna; Schmedt, Thore; Benischke, Anne-Sophie; Hamill, Cecily; Chen, Yuming; Santos, Janine Hertzog

    2016-01-01

    Abstract Aims: Fuchs endothelial corneal dystrophy (FECD), a leading cause of age-related corneal edema requiring transplantation, is characterized by rosette formation of corneal endothelium with ensuing apoptosis. We sought to determine whether excess of mitochondrial reactive oxygen species leads to chronic accumulation of oxidative DNA damage and mitochondrial dysfunction, instigating cell death. Results: We modeled the pathognomonic rosette formation of postmitotic corneal cells by increasing endogenous cellular oxidative stress with menadione (MN) and performed a temporal analysis of its effect in normal (HCEnC, HCECi) and FECD (FECDi) cells and ex vivo specimens. FECDi and FECD ex vivo specimens exhibited extensive mtDNA and nDNA damage as detected by quantitative PCR. Exposure to MN triggered an increase in mitochondrial superoxide levels and led to mtDNA and nDNA damage, while DNA amplification was restored with NAC pretreatment. Furthermore, MN exposure led to a decrease in ΔΨm and adenosine triphosphate levels in normal cells, while FECDi exhibited mitochondrial dysfunction at baseline. Mitochondrial fragmentation and cytochrome c release were detected in FECD tissue and after MN treatment of HCEnCs. Furthermore, cleavage of caspase-9 and caspase-3 followed MN-induced cytochrome c release in HCEnCs. Innovation: This study provides the first line of evidence that accumulation of oxidative DNA damage leads to rosette formation, loss of functionally intact mitochondria via fragmentation, and subsequent cell death during postmitotic cell degeneration of ocular tissue. Conclusion: MN induced rosette formation, along with mtDNA and nDNA damage, mitochondrial dysfunction, and fragmentation, leading to activation of the intrinsic apoptosis via caspase cleavage and cytochrome c release. Antioxid. Redox Signal. 24, 1072–1083. PMID:26935406

  12. Menadione-Induced DNA Damage Leads to Mitochondrial Dysfunction and Fragmentation During Rosette Formation in Fuchs Endothelial Corneal Dystrophy.

    PubMed

    Halilovic, Adna; Schmedt, Thore; Benischke, Anne-Sophie; Hamill, Cecily; Chen, Yuming; Santos, Janine Hertzog; Jurkunas, Ula V

    2016-06-20

    Fuchs endothelial corneal dystrophy (FECD), a leading cause of age-related corneal edema requiring transplantation, is characterized by rosette formation of corneal endothelium with ensuing apoptosis. We sought to determine whether excess of mitochondrial reactive oxygen species leads to chronic accumulation of oxidative DNA damage and mitochondrial dysfunction, instigating cell death. We modeled the pathognomonic rosette formation of postmitotic corneal cells by increasing endogenous cellular oxidative stress with menadione (MN) and performed a temporal analysis of its effect in normal (HCEnC, HCECi) and FECD (FECDi) cells and ex vivo specimens. FECDi and FECD ex vivo specimens exhibited extensive mtDNA and nDNA damage as detected by quantitative PCR. Exposure to MN triggered an increase in mitochondrial superoxide levels and led to mtDNA and nDNA damage, while DNA amplification was restored with NAC pretreatment. Furthermore, MN exposure led to a decrease in ΔΨm and adenosine triphosphate levels in normal cells, while FECDi exhibited mitochondrial dysfunction at baseline. Mitochondrial fragmentation and cytochrome c release were detected in FECD tissue and after MN treatment of HCEnCs. Furthermore, cleavage of caspase-9 and caspase-3 followed MN-induced cytochrome c release in HCEnCs. This study provides the first line of evidence that accumulation of oxidative DNA damage leads to rosette formation, loss of functionally intact mitochondria via fragmentation, and subsequent cell death during postmitotic cell degeneration of ocular tissue. MN induced rosette formation, along with mtDNA and nDNA damage, mitochondrial dysfunction, and fragmentation, leading to activation of the intrinsic apoptosis via caspase cleavage and cytochrome c release. Antioxid. Redox Signal. 24, 1072-1083.

  13. Analysis of the learning curve for pre-cut corneal specimens in preparation for lamellar transplantation: a prospective, single-centre, consecutive case series prepared at the Lions New South Wales Eye Bank.

    PubMed

    Martin, Aifric Isabel; Devasahayam, Rajnesh; Hodge, Christopher; Cooper, Simon; Sutton, Gerard L

    2017-09-01

    This study is the first paper to establish a learning curve by a single technician. Preparation of pre-cut corneal endothelial grafts commenced at Lions New South Wales Eye Bank in December 2014. The primary objective of this study was to review the safety and reliability of the preparation method during the first year of production. This is a hospital-based, prospective case series. There were 234 consecutive donor corneal lenticules. Donor lenticules were prepared by a single operator using a linear cutting microkeratome. Immediately prior to cutting, central corneal thickness values were recorded. Measurements of the corneal bed were taken immediately following lenticule preparation. Outcomes were separated by blade sizes, and intended thickness was compared to actual thickness for each setting. Early specimens were compared to later ones to assess for a learning curve within the technique. The main parameter measured is the mean difference from intended lamellar cut thickness. The mean final cut thickness was 122.36 ± 20.35 μm, and the mean difference from intended cut was 30.17 ± 37.45 μm. No significant difference was found between results achieved with early specimens versus those achieved with later specimens (P = 0.425). Thin, reproducible endothelial grafts can routinely be produced by trained technicians at their respective eye banks without significant concerns for an extended learning curve. This service can reduce perioperative surgical complexity, required surgical paraphernalia and theatre times. The consistent preparation of single-pass, ultrathin pre-cut corneas may have additional advantages for surgeons seeking to introduce lamellar techniques. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  14. Topographic hot spot before descemet stripping automated endothelial keratoplasty is associated with postoperative hyperopic shift.

    PubMed

    Shimizu, Tsutomu; Yamaguchi, Takefumi; Satake, Yoshiyuki; Shimazaki, Jun

    2015-03-01

    The aim of this study was to investigate topographic "hot spots" on the anterior corneal surface before Descemet stripping automated endothelial keratoplasty (DSAEK) and their effects on postoperative visual acuity and hyperopic shift. Twenty-seven eyes of 27 patients with bullous keratopathy, who underwent DSAEK were studied. We defined a hot spot as a focal area with relatively high refractive power on the anterior corneal surface in eyes with bullous keratopathy. Refractive spherical equivalent, keratometric value, and corneal topography were retrospectively evaluated using anterior segment optical coherence tomography (AS-OCT). Hot spots were identified in 11 eyes (42.3%) before DSAEK and disappeared in 9 eyes of these eyes (81.8%) at 6 months after DSAEK. AS-OCT revealed focal epithelial thickening in the same areas as the hot spots. There was no significant difference in the postoperative visual acuity between eyes with and without hot spots (P > 0.05). The keratometric value of the anterior corneal surface significantly flattened from 45.7 ± 2.7 diopters (D) before DSAEK to 44.2 ± 2.7 D 1 month after DSAEK in eyes with hot spots (P = 0.01), whereas in eyes without hot spots, there were no significant differences in the keratometric values before and after DSAEK. At 6 months, the refractive change was +1.1 ± 1.3 D in eyes with hot spots and -0.2 ± 0.6 D in eyes without hot spots (P = 0.034). In eyes with focal epithelial thickening, topographic hot spots on the anterior corneal surface were observed using AS-OCT. The hot spots disappeared after DSAEK and had no influence on the postoperative visual acuity.

  15. Functional assessment of SLC4A11, an integral membrane protein mutated in corneal dystrophies

    PubMed Central

    Loganathan, Sampath K.; Schneider, Hans-Peter; Morgan, Patricio E.; Deitmer, Joachim W.

    2016-01-01

    SLC4A11, a member of the SLC4 family of bicarbonate transporters, is a widely expressed integral membrane protein, abundant in kidney and cornea. Mutations of SLC4A11 cause some cases of the blinding corneal dystrophies, congenital hereditary endothelial dystrophy, and Fuchs endothelial corneal dystrophy. These diseases are marked by fluid accumulation in the corneal stroma, secondary to defective fluid reabsorption by the corneal endothelium. The role of SLC4A11 in these corneal dystrophies is not firmly established, as SLC4A11 function remains unclear. To clarify the normal function(s) of SLC4A11, we characterized the protein following expression in the simple, low-background expression system Xenopus laevis oocytes. Since plant and fungal SLC4A11 orthologs transport borate, we measured cell swelling associated with accumulation of solute borate. The plant water/borate transporter NIP5;1 manifested borate transport, whereas human SLC4A11 did not. SLC4A11 supported osmotically driven water accumulation that was electroneutral and Na+ independent. Studies in oocytes and HEK293 cells could not detect Na+-coupled HCO3− transport or Cl−/HCO3− exchange by SLC4A11. SLC4A11 mediated electroneutral NH3 transport in oocytes. Voltage-dependent OH− or H+ movement was not measurable in SLC4A11-expressing oocytes, but SLC4A11-expressing HEK293 cells manifested low-level cytosolic acidification at baseline. In mammalian cells, but not oocytes, OH−/H+ conductance may arise when SLC4A11 activates another protein or itself is activated by another protein. These data argue against a role of human SLC4A11 in bicarbonate or borate transport. This work provides additional support for water and ammonia transport by SLC4A11. When expressed in oocytes, SLC4A11 transported NH3, not NH3/H+. PMID:27558157

  16. Lactate-H+ Transport Is a Significant Component of the In Vivo Corneal Endothelial Pump

    PubMed Central

    Nguyen, Tracy T.; Bonanno, Joseph A.

    2012-01-01

    Purpose. To confirm the expression of monocarboxylate transporters (MCT) 1, 2, and 4 in rabbit CE and to test the hypothesis that cellular buffering contributed by HCO3−, NBCe1, and carbonic anhydrase (CA) activity facilitates lactate-H+ efflux thereby controlling corneal hydration in vivo. Methods. MCT1–4 expression of rabbit endothelium was examined by Western blotting and immunofluorescence staining. Lactate-induced acidification (LIA) was measured in perfused CE in the presence and absence of HCO3− and acetazolamide (ACTZ) using tissue treated with siRNA specific to MCT1, 2, and 4. Corneal thickness and lactate concentration were measured in New Zealand White rabbits treated with the topical CA inhibitor Azopt, and from eyes that were injected intracamerally with ouabain, disodium 4,4′-diisothiocyanatostilbene-2,2′-disulfonate (DIDS), and shRNA specific to the 1Na+:2HCO3− cotransporter NBCe1. Results. MCT1 and MCT4 are localized to the lateral membrane, while MCT2 is apical. Cell pH measurements showed LIA in response to 40 mM lactate in bicarbonate free (BF) Ringer's that was inhibited by niflumic acid and by MCT siRNA knockdown, and significantly reduced in the presence of HCO3−. Lactate-dependent proton flux in vitro was not significantly greater in the presence of HCO3− or reduced by ACTZ. However, when active transport, NBCe1, or CA activity was disrupted in vivo, corneal edema ensued and was associated with significant corneal lactate accumulation. Conclusions. MCT1, 2, and 4 are expressed in rabbit CE on both the apical and basolateral surfaces and function to transport lactate-H+. Lactate-H+ flux is facilitated by active transport, HCO3− transport and CA activity, disruption of which causes corneal edema in vivo and indicates that facilitation of lactate efflux is a component of the endothelial pump. PMID:22410572

  17. Impact of eye bank lamellar tissue cutting for endothelial keratoplasty on bacterial and fungal corneoscleral donor rim cultures after corneal transplantation.

    PubMed

    Rauen, Matthew P; Goins, Kenneth M; Sutphin, John E; Kitzmann, Anna S; Schmidt, Gregory A; Wagoner, Michael D

    2012-04-01

    To determine if the lamellar cut of donor tissue for endothelial keratoplasty (EK) by an eye bank facility is associated with a change in the prevalence of positive bacterial or fungal donor rim cultures after corneal transplantation. A retrospective review was conducted of bacterial and fungal cultures of donor rims used for corneal transplantation at a tertiary eye care center from January 1, 2003, to December 31, 2008, with tissue provided by a single eye bank. The cases were divided into 2 groups. Group 1 ("no-cut") included keratoplasty procedures in which a lamellar cut was not performed. Group 2 ("precut") included EK procedures in which a 4-hour period of prewarming of tissue followed by a lamellar cut was performed in the eye bank before tissue delivery to the operating surgeon. There were 351 donor rim cultures in group 1 and 278 in group 2. Bacterial cultures were positive in 30 donor rims (8.5%) in group 1 and 13 (4.7%) in group 2 (P = 0.058). Positive bacterial cultures were not associated with any postoperative infections. Fungal cultures were positive in 8 donor rims (2.3%) in group 1 and 7 (2.5%) in group 2 (P = 1.0). Positive fungal cultures were associated with 2 cases (13.3%) of postoperative fungal infections. Corneal donor tissue can be precut for EK by trained eye bank personnel without an increased risk of bacterial or fungal contamination.

  18. Correction of low corneal astigmatism in cataract surgery.

    PubMed

    Leon, Pia; Pastore, Marco Rocco; Zanei, Andrea; Umari, Ingrid; Messai, Meriem; Negro, Corrado; Tognetto, Daniele

    2015-01-01

    To evaluate and compare aspheric toric intraocular lens (IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI) to manage low corneal astigmatism (1.0-2.0 D) in cataract surgery. A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan). Follow-up lasted 6mo. The mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01). No difference was observed in the postoperative endothelial cell count between the two groups. The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision.

  19. Correction of low corneal astigmatism in cataract surgery

    PubMed Central

    Leon, Pia; Pastore, Marco Rocco; Zanei, Andrea; Umari, Ingrid; Messai, Meriem; Negro, Corrado; Tognetto, Daniele

    2015-01-01

    AIM To evaluate and compare aspheric toric intraocular lens (IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI) to manage low corneal astigmatism (1.0-2.0 D) in cataract surgery. METHODS A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan). Follow-up lasted 6mo. RESULTS The mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01). No difference was observed in the postoperative endothelial cell count between the two groups. CONCLUSION The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision. PMID:26309869

  20. Eye bank survey of surgeons using precut donor tissue for descemet stripping automated endothelial keratoplasty.

    PubMed

    Kitzmann, Anna S; Goins, Kenneth M; Reed, Cynthia; Padnick-Silver, Lissa; Macsai, Marian S; Sutphin, John E

    2008-07-01

    To assess surgeon satisfaction with precut corneal tissue from 1 eye bank for Descemet stripping automated endothelial keratoplasty (DSAEK). Surgical techniques and predictors of procedural success were also examined. A 19-question survey was completed by 53 surgeons around the United States for 197 DSAEK cases using prepared corneal allograft tissue from the Iowa Lions Eye Bank. Surgeries were performed between April 1 and December 31, 2006; surveys were completed retrospectively within a few weeks of surgery. Tissue was found to be acceptable in 98% of DSAEK cases reported. Difficulties with precut tissue (eg, lack of anterior cap adherence to the posterior lamella, not visible or decentered central dot, anterior edge undermining) were reported in approximately 10% of cases. A rebubbling procedure was performed in 23% of cases for donor dislocations. The donor lenticule adhered, with resulting corneal deturgescence, in 86% of cases. Surgeons declared a successful procedure in 92% of cases. Of the 14 unsuccessful cases, donor tissue quality was the underlying etiology in only 1 case. Procedural success rates were related to surgeon experience (P = 0.002), lenticule adherence after only 1 anterior chamber air bubble (P = 0.005), no small perforations to release fluid (P = 0.005), and the presence of corneal deturgescence (P = 0.002). The use of precut tissue for DSAEK is not associated with increased risk of complications related to tissue preparation. With standardization of precutting donor tissue, safety of DSAEK surgery may be improved while increasing surgeon efficiency.

  1. Human corneal endothelial cell transplantation using nanocomposite gel sheet in bullous keratopathy.

    PubMed

    Parikumar, Periasamy; Haraguchi, Kazutoshi; Senthilkumar, Rajappa; Abraham, Samuel Jk

    2018-01-01

    Transplantation of in vitro expanded human corneal endothelial precursors (HCEP) cells using a nanocomposite (D25-NC) gel sheet as supporting material in bovine's cornea has been earlier reported. Herein we report the transplantation of HCEP cells derived from a cadaver donor cornea to three patients using the NC gel sheet. In three patients with bullous keratopathy, one after cataract surgery, one after trauma and another in the corneal graft, earlier performed for congenital corneal dystrophy, not amenable to medical management HCEP cells isolated from a human cadaver donor cornea in vitro expanded using a thermoreversible gelation polymer (TGP) for 26 days were divided into three equal portions and 1.6 × 10 5 HCEP cells were injected on to the endothelium of the affected eye in each patient using the D25-NC gel sheet as a supporting material. The sheets were removed after three days. The bullae in the cornea disappeared by the 3 rd -11 th post-operative day in all the three patients. Visual acuity improved from Perception of light (PL)+/Projection of rays (PR)+ to Hand movements (HM)+ in one of the patients by post-operative day 3 which was maintained at 18 months follow-up. At 18 months follow-up, in another patient the visual acuity had improved from HM+ to 6/60 while in the third patient, visual acuity remained HM+ as it was prior to HCEP transplantation. There were no adverse effects during the follow-up in any of the patients.

  2. Evaluating the Toxicity/Fixation Balance for Corneal Cross-Linking With Sodium Hydroxymethylglycinate (SMG) and Riboflavin-UVA (CXL) in an Ex Vivo Rabbit Model Using Confocal Laser Scanning Fluorescence Microscopy.

    PubMed

    Kim, Su-Young; Babar, Natasha; Munteanu, Emilia Laura; Takaoka, Anna; Zyablitskaya, Mariya; Nagasaki, Takayuki; Trokel, Stephen L; Paik, David C

    2016-04-01

    To develop methods to delineate the relationship between endothelial cell toxicity and tissue fixation (toxicity/fixation) using sodium hydroxymethylglycinate (SMG), a formaldehyde releaser, and riboflavin-UVA photochemical corneal cross-linking (CXL) for therapeutic tissue cross-linking of the cornea. Eleven fresh cadaveric rabbit heads were used for ex vivo corneal cross-linking simulation. After epithelial debridement, the tissue was exposed to 1/4 max (9.8 mM) or 1/3 max (13 mM) SMG at pH 8.5 for 30 minutes or riboflavin-UVA (CXL). The contralateral cornea served as a paired control. Postexposure, cross-linking efficacy was determined by thermal denaturation temperature (Tm) and endothelial damage was assessed using calcein AM and ethidium homodimer staining (The Live/Dead Kit). Confocal laser scanning fluorescence microscopy was used to generate live/dead cell counts using a standardized algorithm. The ΔTm after CXL, 1/3 SMG, and 1/4 SMG was 2.2 ± 0.9°C, 1.3 ± 0.5°C, and 1.1 ± 0.5°C, respectively. Endothelial cell damage was expressed as the percent of dead cells/live + dead cells counted per high-power field. The values were 3 ± 1.7% (control) and 8.9 ± 11.1% (CXL) (P = 0.390); 1 ± 0.2% (control) and 19.5 ± 32.2% (1/3 max SMG) (P = 0.426); and 2.7 ± 2.4% (control) and 2.8 ± 2.2% (1/4 max SMG) (P = 0.938). The values for endothelial toxicity were then indexed over the shift in Tm to yield a toxicity/fixation index. The values were as follows: 2.7 for CXL, 14 for 1/3 max, and 0.1 for 1/4 max. Quarter max (1/4 max = 9.8 mM) SMG effectively cross-linked tissue and was nontoxic to endothelial cells. Thus, SMG is potentially a compound that could achieve both desired effects.

  3. Enhancement on primate corneal endothelial cell survival in vitro by a ROCK inhibitor.

    PubMed

    Okumura, Naoki; Ueno, Morio; Koizumi, Noriko; Sakamoto, Yuji; Hirata, Kana; Hamuro, Junji; Kinoshita, Shigeru

    2009-08-01

    The transplantation of cultivated corneal endothelial cells (CECs) has gained attention recently for the treatment of patients with corneal endothelial dysfunction. However, an efficient culturing technique for human (H)CECs has yet to be properly established. The present study was conducted to investigate the applicability of the Rho kinase (ROCK) inhibitor Y-27632 in promoting cultivation of cynomolgus monkey (M)CECs. MCECs of cynomolgus monkeys were cultured in a medium containing 10 microM Y-27632. The number of viable cells adherent to culture plates were monitored by a luminescent cell-viability assay and colony growth was detected by toluidine blue staining. Proliferating cells were detected by Ki67 expression using flow cytometry and a BrdU-labeling assay for immunocytochemistry. Annexin V-positive apoptotic cells were analyzed by flow cytometry. The number of viable cultivated MCECs was enhanced by Y-27632 addition after 24 hours in culture. The colony area of the culture in the presence of Y-27632 was higher than in the absence of Y-27632 on day 10. In Y-27632-treated cultures, the number of Ki67-positive cells was significantly increased at 24 and 48 hours, and the number of proliferating BrdU-positive cells was increased at 48 hours. The number of Annexin V-positive apoptotic cells was decreased at 24 hours. The inhibition of Rho/ROCK signaling by specific ROCK inhibitor Y-27632 promoted the adhesion of MCECs, inhibited apoptosis, and increased the number of proliferating cells. These results suggest that the ROCK inhibitor may serve as a new tool for cultivating HCECs for transplantation.

  4. Corneal dystrophies

    PubMed Central

    Klintworth, Gordon K

    2009-01-01

    The term corneal dystrophy embraces a heterogenous group of bilateral genetically determined non-inflammatory corneal diseases that are restricted to the cornea. The designation is imprecise but remains in vogue because of its clinical value. Clinically, the corneal dystrophies can be divided into three groups based on the sole or predominant anatomical location of the abnormalities. Some affect primarily the corneal epithelium and its basement membrane or Bowman layer and the superficial corneal stroma (anterior corneal dystrophies), the corneal stroma (stromal corneal dystrophies), or Descemet membrane and the corneal endothelium (posterior corneal dystrophies). Most corneal dystrophies have no systemic manifestations and present with variable shaped corneal opacities in a clear or cloudy cornea and they affect visual acuity to different degrees. Corneal dystrophies may have a simple autosomal dominant, autosomal recessive or X-linked recessive Mendelian mode of inheritance. Different corneal dystrophies are caused by mutations in the CHST6, KRT3, KRT12, PIP5K3, SLC4A11, TACSTD2, TGFBI, and UBIAD1 genes. Knowledge about the responsible genetic mutations responsible for these disorders has led to a better understanding of their basic defect and to molecular tests for their precise diagnosis. Genes for other corneal dystrophies have been mapped to specific chromosomal loci, but have not yet been identified. As clinical manifestations widely vary with the different entities, corneal dystrophies should be suspected when corneal transparency is lost or corneal opacities occur spontaneously, particularly in both corneas, and especially in the presence of a positive family history or in the offspring of consanguineous parents. Main differential diagnoses include various causes of monoclonal gammopathy, lecithin-cholesterol-acyltransferase deficiency, Fabry disease, cystinosis, tyrosine transaminase deficiency, systemic lysosomal storage diseases (mucopolysaccharidoses, lipidoses, mucolipidoses), and several skin diseases (X-linked ichthyosis, keratosis follicularis spinolosa decalvans). The management of the corneal dystrophies varies with the specific disease. Some are treated medically or with methods that excise or ablate the abnormal corneal tissue, such as deep lamellar endothelial keratoplasty (DLEK) and phototherapeutic keratectomy (PTK). Other less debilitating or asymptomatic dystrophies do not warrant treatment. The prognosis varies from minimal effect on the vision to corneal blindness, with marked phenotypic variability. PMID:19236704

  5. Corneal transplantation in the United Kingdom and Republic of Ireland.

    PubMed Central

    Vail, A; Gore, S M; Bradley, B A; Easty, D L; Rogers, C A

    1993-01-01

    The Corneal Transplant Follow up Study has registered 4560 corneal grafts performed in the United Kingdom and Republic of Ireland from July 1987 to June 1991. Rates of reported grafts doubled during that time. This increase was greater for surgeons and regions reporting fewer grafts, but was consistent across patient factors. Eleven of 428 consultants were responsible for over 25% of grafts, and their patients' characteristics differed significantly from others. Overall, reasons for grafting were visual only (77%), visual and other (16%), and non-visual (7%). Most frequent diagnoses were endothelial failure (38%), inflammation (26%), and keratoconus (20%). Age ranged from 2 months to 97 years, and differed markedly with diagnosis. Eighteen per cent of transplants were regrafts, and 40% were vascularised preoperatively. PMID:8218035

  6. Effect of glaucoma tube shunt parameters on cornea endothelial cells in patients with Ahmed valve implants.

    PubMed

    Koo, Euna B; Hou, Jing; Han, Ying; Keenan, Jeremy D; Stamper, Robert L; Jeng, Bennie H

    2015-01-01

    The aim of this study was to assess the effect of various tube parameters on corneal endothelial cell density (ECD) after insertion of Ahmed valves. Thirty-nine eyes of 33 patients with previous superotemporal (ST) Ahmed valve implantation and 20 eyes of 13 participants with previous uncomplicated phacoemulsification and intraocular lens implantation but no history of glaucoma surgery were evaluated. Various tube parameters were measured with anterior segment optical coherence tomography. ST, central, and inferonasal (IN) ECD and pachymetry were measured. Endothelial cell loss and corneal thickness in the ST cornea was compared with those in the IN cornea. The mean age of the operated patients was 58 ± 22 years, and the mean time since glaucoma surgery was 2.5 ± 2.6 years. Thirty-two of the 39 study eyes were pseudophakic. The ECD was significantly lower in the ST endothelium than in the IN endothelium in eyes with glaucoma tube surgery (P < 0.001), although this relative reduction in ST ECD was not greater than that seen in pseudophakic control eyes (P = 0.16). In univariate analysis, tube angle relative to the cornea and distance from the tip of the tube to the cornea were significant risk factors for decreased ST endothelial cell loss when assessed relative to the IN ECD (P = 0.01 and P = 0.02, respectively). In multivariate analysis, only the distance of the tube tip to the cornea remained significantly associated with ST endothelial cell loss. Although this was a retrospective study with inherent limitations, tubes that are closer to the cornea seem to lead to increased loss of adjacent endothelial cells.

  7. Corneal endothelial cell density and morphology in normal Iranian eyes

    PubMed Central

    Hashemian, Mohammad Nasser; Moghimi, Sasan; Fard, Masood Aghsaie; Fallah, Mohammad Reza; Mansouri, Mohammad Reza

    2006-01-01

    Background We describe corneal endothelial cell density and morphology in normal Iranian eyes and compare endothelial cell characteristics in the Iranian population with data available in the literature for American and Indian populations. Methods Specular microscopy was performed in 525 eyes of normal Iranian people aged 20 to 85 years old. The studied parameters including mean endothelial cell density (MCD), mean cell area (MCA) and coefficient of variation (CV) in cell area were analyzed in all of the 525 eyes. Results MCD was 1961 ± 457 cell/mm2 and MCA was 537.0 ± 137.4 μm2. There was no statistically significant difference in MCD, MCA and CV between genders (Student t-test, P = 0.85, P = 0.97 and P = 0.15 respectively). There was a statistically significant decrease in MCD with age (P < 0.001, r = -0.64). The rate of cell loss was 0.6% per year. There was also a statistically significant increase in MCA (P < 0.001,r = 0.56) and CV (P < 0.001, r = 0.30) from 20 to 85 years of age. Conclusion The first normative data for the endothelium of Iranian eyes seems to confirm that there are no differences in MCD, MCA and CV between genders. Nevertheless, the values obtained in Iranian eyes seem to be different to those reported by the literature in Indian and American populations. PMID:16519812

  8. Corneal endothelial cell density and morphology in normal Iranian eyes.

    PubMed

    Hashemian, Mohammad Nasser; Moghimi, Sasan; Fard, Masood Aghsaie; Fallah, Mohammad Reza; Mansouri, Mohammad Reza

    2006-03-06

    We describe corneal endothelial cell density and morphology in normal Iranian eyes and compare endothelial cell characteristics in the Iranian population with data available in the literature for American and Indian populations. Specular microscopy was performed in 525 eyes of normal Iranian people aged 20 to 85 years old. The studied parameters including mean endothelial cell density (MCD), mean cell area (MCA) and coefficient of variation (CV) in cell area were analyzed in all of the 525 eyes. MCD was 1961 +/- 457 cell/mm2 and MCA was 537.0 +/- 137.4 microm2. There was no statistically significant difference in MCD, MCA and CV between genders (Student t-test, P = 0.85, P = 0.97 and P = 0.15 respectively). There was a statistically significant decrease in MCD with age (P < 0.001, r = -0.64). The rate of cell loss was 0.6% per year. There was also a statistically significant increase in MCA (P < 0.001,r = 0.56) and CV (P < 0.001, r = 0.30) from 20 to 85 years of age. The first normative data for the endothelium of Iranian eyes seems to confirm that there are no differences in MCD, MCA and CV between genders. Nevertheless, the values obtained in Iranian eyes seem to be different to those reported by the literature in Indian and American populations.

  9. No-Touch Technique and a New Donor Adjuster for Descemet's Stripping Automated Endothelial Keratoplasty

    PubMed Central

    Kobayashi, Akira; Yokogawa, Hideaki; Sugiyama, Kazuhisa

    2012-01-01

    Purpose One difficulty with Descemet's stripping automated endothelial keratoplasty (DSAEK) is air management during surgery and donor endothelial lamella centering. We evaluated the no-touch technique for donor centering and the use of a newly developed DSAEK donor adjuster. Methods We evaluated the records of 12 consecutive patients (mean age 75.3 years) with bullous keratopathy who had undergone DSAEK. In all cases, the no-touch technique was attempted first. When the no-touch technique failed, a DSAEK donor adjuster with a 30-gauge cannula resembling a curved reverse Sinskey hook was used for donor centering. The adjuster allows air injection during donor centering. Results The no-touch technique using simple corneal surface massage to center the graft was successful in 4 cases (33.3%), while 4 cases required ocular tilting (33.3%) in addition to corneal surface massage. The no-touch technique was ineffective in 4 cases (33.3%), but the donor adjuster was used successfully and easily for these patients. Comparing the endothelial cell loss rate between the no-touch technique group and the donor adjuster group, there was no significant difference at 6 months. Conclusions The no-touch technique was useful for better control of DSAEK donor centering in most cases. When the no-touch technique was ineffective, the DSAEK donor adjuster was uniformly successful. PMID:22807910

  10. [Automated analyser of organ cultured corneal endothelial mosaic].

    PubMed

    Gain, P; Thuret, G; Chiquet, C; Gavet, Y; Turc, P H; Théillère, C; Acquart, S; Le Petit, J C; Maugery, J; Campos, L

    2002-05-01

    Until now, organ-cultured corneal endothelial mosaic has been assessed in France by cell counting using a calibrated graticule, or by drawing cells on a computerized image. The former method is unsatisfactory because it is characterized by a lack of objective evaluation of the cell surface and hexagonality and it requires an experienced technician. The latter method is time-consuming and requires careful attention. We aimed to make an efficient, fast and easy to use, automated digital analyzer of video images of the corneal endothelium. The hardware included a PC Pentium III ((R)) 800 MHz-Ram 256, a Data Translation 3155 acquisition card, a Sony SC 75 CE CCD camera, and a 22-inch screen. Special functions for automated cell boundary determination consisted of Plug-in programs included in the ImageTool software. Calibration was performed using a calibrated micrometer. Cell densities of 40 organ-cultured corneas measured by both manual and automated counting were compared using parametric tests (Student's t test for paired variables and the Pearson correlation coefficient). All steps were considered more ergonomic i.e., endothelial image capture, image selection, thresholding of multiple areas of interest, automated cell count, automated detection of errors in cell boundary drawing, presentation of the results in an HTML file including the number of counted cells, cell density, coefficient of variation of cell area, cell surface histogram and cell hexagonality. The device was efficient because the global process lasted on average 7 minutes and did not require an experienced technician. The correlation between cell densities obtained with both methods was high (r=+0.84, p<0.001). The results showed an under-estimation using manual counting (2191+/-322 vs. 2273+/-457 cell/mm(2), p=0.046), compared with the automated method. Our automated endothelial cell analyzer is efficient and gives reliable results quickly and easily. A multicentric validation would allow us to standardize cell counts among cornea banks in our country.

  11. Impact of Donor Age on Corneal Endothelium-Descemet Membrane Layer Scroll Formation

    PubMed Central

    Bennett, Adam; Mahmoud, Shahira; Drury, Donna; Cavanagh, H. Dwight; McCulley, James P.; Petroll, W. Matthew; Mootha, V. Vinod

    2014-01-01

    Objectives To correlate corneal endothelium-Descemet membrane layer (EDM) parameters of scroll tightness with donor age, endothelial cell density, and history of diabetes. Methods EDM scrolls were harvested from 26 corneoscleral buttons using the SCUBA technique by a cornea-fellowship trained ophthalmologist masked to donor age. Two independent outcome parameters were used to characterize the scrolling severity of successfully harvested tissue: scroll width and tendency for EDM scroll formation (referred to as scroll rating on a 1 to 4 scale: incomplete scroll formation to tightly-scrolled). Results Mean donor age was 59 ± 17years (15–69). Mean endothelial cell density of EDM scroll was 2451 ± 626 cells/mm2 mm (range: 1307 – 3195). Using stepwise linear regression, a significant correlation was found between scroll width and donor age (R = 0.497, P < 0.05). Additionally, a significant inverse correlation was found between scroll width and endothelial cell density (R = −0.605, P < 0.05). There was no statistically significant correlation between a donor history of diabetes and the parameters of scrolling tendency. Conclusions Our data suggests that using older donors reduces EDM scroll tightness. PMID:25603436

  12. Inhibition of Ultraviolet B-Induced Expression of the Proinflammatory Cytokines TNF-α and VEGF in the Cornea by Fucoxanthin Treatment in a Rat Model.

    PubMed

    Chen, Shiu-Jau; Lee, Ching-Ju; Lin, Tzer-Bin; Liu, Hsiang-Jui; Huang, Shuan-Yu; Chen, Jia-Zeng; Tseng, Kuang-Wen

    2016-01-07

    Ultraviolet B (UVB) irradiation is the most common cause of radiation damage to the eyeball and is a risk factor for human corneal damage. We determined the protective effect of fucoxanthin, which is a carotenoid found in common edible seaweed, on ocular tissues against oxidative UVB-induced corneal injury. The experimental rats were intravenously injected with fucoxanthin at doses of 0.5, 5 mg/kg body weight/day or with a vehicle before UVB irradiation. Lissamine green for corneal surface staining showed that UVB irradiation caused serious damage on the corneal surface, including severe epithelial exfoliation and deteriorated epithelial smoothness. Histopathological lesion examination revealed that levels of proinflammatory cytokines, including tumor necrosis factor-α (TNF-α) and vascular endothelial growth factor (VEGF), significantly increased. However, pretreatment with fucoxanthin inhibited UVB radiation-induced corneal disorders including evident preservation of corneal surface smoothness, downregulation of proinflammatory cytokine expression, and decrease of infiltrated polymorphonuclear leukocytes from UVB-induced damage. Moreover, significant preservation of the epithelial integrity and inhibition of stromal swelling were also observed after UVB irradiation in fucoxanthin-treated groups. Pretreatment with fucoxanthin may protect against UVB radiation-induced corneal disorders by inhibiting expression of proinflammatory factors, TNF-α, and VEGF and by blocking polymorphonuclear leukocyte infiltration.

  13. Breakdown evaluation of corneal epithelial barrier caused by antiallergic eyedrops using an electrophysiologic method.

    PubMed

    Nakashima, Mikiro; Nakamura, Tadahiro; Teshima, Mugen; To, Hideto; Uematsu, Masafumi; Kitaoka, Takashi; Taniyama, Kotaro; Nishida, Koyo; Nakamura, Junzo; Sasaki, Hitoshi

    2008-02-01

    The aim of this study was to examine the usefulness of an electrophysiologic method for predicting corneal epithelial breakdown by antiallergic eyedrops and comparing the results with those in other appraisal methods. Six kinds of antiallergic eyedrops, including benzalkonium chloride (BK) as an ophthalmic preservative and two kinds of BK-free antiallergic eyedrops, were used in this study. Eyedrops were applied to excise rabbit corneas and monitoring was performed according to an electrophysiologic method, using a commercially available chamber system to mimic human tear turnover. Changes in transepithelial electrical resistance (TEER) in the corneal surface were recorded. The cytotoxicity of each kind of eyedrops in a normal rabbit corneal epithelial (NRCE) cell line and a human endothelial cell line EA.hy926 was also examined. The extent of decrease in the corneal TEER after applying antiallergic eyedrops was dependent on the concentration of the BK included as a preservative, but it was also affected by the different kinds of drugs when the BK concentration was low. Higher cytotoxicity of the eyedrops against the NRCE and EA.hy926 cell lines was observed with a reduction of TEER. Monitoring changes in the corneal TEER, according to the electrophysiologic method with the application of antiallergic eyedrops, is useful for predicting corneal epithelial breakdown caused by their instillation.

  14. Efficacy and Safety Comparison Between Suberoylanilide Hydroxamic Acid and Mitomycin C in Reducing the Risk of Corneal Haze After PRK Treatment In Vivo.

    PubMed

    Anumanthan, Govindaraj; Sharma, Ajay; Waggoner, Michael; Hamm, Chuck W; Gupta, Suneel; Hesemann, Nathan P; Mohan, Rajiv R

    2017-12-01

    This study compared the efficacy and safety of suberoylanilide hydroxamic acid (SAHA) and mitomycin C (MMC) up to 4 months in the prevention of corneal haze induced by photorefractive keratectomy (PRK) in rabbits in vivo. Corneal haze in rabbits was produced with -9.00 diopter PRK. A single application of SAHA (25 μM) or MMC (0.02%) was applied topically immediately after PRK. Effects of the two drugs were analyzed by slit-lamp microscope, specular microscope, TUNEL assay, and immunofluorescence. Single topical adjunct use of SAHA (25 μM) or MMC (0.02%) after PRK attenuated more than 95% corneal haze and myofibroblast formation (P < .001). SAHA did not reduce keratocyte density, cause keratocyte apoptosis, or increase immune cell infiltration compared to MMC (P < .01 or .001). Furthermore, SAHA dosing did not compromise corneal endothelial phenotype, density, or function in rabbit eyes, whereas MMC application did (P < .01 or .001). SAHA and MMC significantly decreased corneal haze after PRK in rabbits in vivo. SAHA exhibited significantly reduced short- and long-term damage to the corneal endothelium compared to MMC in rabbits. SAHA is an effective and potentially safer alternative to MMC for the prevention of corneal haze after PRK. Clinical trials are warranted. [J Refract Surg. 2017;33(12):834-839.]. Copyright 2017, SLACK Incorporated.

  15. An unusual case of feline acute corneal hydrops: atypical disease presentation and possible in vivo detection of Descemet's membrane detachment in the cat's unaffected eye.

    PubMed

    Schlesener, Brittany N; Scott, Erin M; Vallone, Lucien V

    2017-11-07

    A 1-year-old, female spayed, domestic shorthair cat presented for blepharospasm of the right eye. Slit-lamp biomicroscopic examination showed focal corneal ulceration and presumptive keratomalacia of the right eye. Examination of the left eye was normal apart from a focal endothelial opacity. Within the first 24 h of medical management, the right eye developed marked corneal edema and globular anterior protrusion of the corneal surface consistent with feline acute corneal hydrops (FACH). Surgical management consisted of a bridge conjunctival graft, nictitating membrane flap, and temporary tarsorrhaphy. Resolution of corneal edema and pain occurred in the right eye within 24 days. Spectral domain optical coherence tomography (SD-OCT) of the anterior segment was performed in both eyes. Conjunctival tissue from the bridge graft precluded examination of deeper corneal structures in the right eye. The left eye displayed a focal separation of the corneal endothelium and Descemet's membrane from the overlying stroma. These SD-OCT findings are similar to the analogous syndrome found in humans and represent a potential etiology for FACH of the right eye in the case presented here. Unfortunately, the cat was lost to follow-up and the progression of this lesion to FACH in the left eye could not be determined. © 2017 American College of Veterinary Ophthalmologists.

  16. Short-term effects of overnight orthokeratology on corneal cell morphology and corneal thickness.

    PubMed

    Nieto-Bona, Amelia; González-Mesa, Ana; Nieto-Bona, Ma Paz; Villa-Collar, César; Lorente-Velázquez, Amalia

    2011-06-01

    To examine the morphological and biometric corneal changes produced over periods of 15 days and 1 month after overnight orthokeratology (OK). Prospective, single-center, longitudinal trial. Twenty-seven right eyes of 27 subjects (group 1) with low to moderate myopia wore OK lenses for 1 month. Ten right eyes of 10 subjects (group 2) with emmetropia to low myopia who did not wear any type of contact lens served as controls. Corneal morphometric measurements were obtained in vivo using a confocal microscope to examine the central and midperipheral cornea. Thickness measurements in the peripheral cornea were obtained by optical coherence tomography. Changes in visual acuity, refractive error, and corneal topography were also analyzed. No significant changes in either endothelial cell or stromal cell density were observed after 1 month of OK. Basal epithelial cells were, however, significantly reduced (P < 0.01), and epithelial wing and superficial cells showed enhanced visibility (P < 0.05). Superficial cells increased in height and width, the width increase after 1 month being significant (P < 0.01). Epithelial thickness was significantly reduced in the central cornea and 2 mm around the center. Corneal pachymetry increased significantly in the band from 5 to 10 mm from the corneal apex (P < 0.01). OK lenses for myopia induce significant structural and optical changes particularly in the central epithelium after 15 days or 1 month of wear. The central corneal epithelium responds to OK wear by undergoing significant epithelial cell shape and size alterations with no effects, however, on the cells of the corneal endothelium or the corneal stroma. Peripheral corneal thickness increased with respect to baseline values. These findings suggest that the corneal epithelium is the principal structure affected by the mechanical forces exerted by the OK lenses.

  17. Using corneal confocal microscopy to track changes in the corneal layers of dry eye patients after autologous serum treatment.

    PubMed

    Mahelkova, Gabriela; Jirsova, Katerina; Seidler Stangova, Petra; Palos, Michalis; Vesela, Viera; Fales, Ivan; Jiraskova, Nada; Dotrelova, Dagmar

    2017-05-01

    In vivo corneal confocal microscopy allows the examination of each layer of the cornea in detail and the identification of pathological changes at the cellular level. The purpose of this study was to identify the possible effects of a three-month treatment with autologous serum eye-drops in different corneal layers of patients with severe dry eye disease using corneal confocal microscopy. Twenty-six patients with dry eye disease were included in the study. Corneal fluorescein staining was performed. The corneas of the right eyes were examined using in vivo corneal confocal microscopy before and after a three-month treatment with autologous serum drops. The densities of superficial and basal epithelial cells, Langerhans cells, the keratocytes and activated keratocytes, the density of endothelial cells and the status of the sub-basal nerve plexus fibres were evaluated. A significant decrease in corneal fluorescein staining was found after the three-month autologous serum treatment (p = 0.0006). The basal epithelial cell density decreased significantly (p = 0.001), while the density of superficial epithelial cells did not change significantly (p = 0.473) nor did the number of Langerhans cells or activated keratocytes (p = 0.223; p = 0.307, respectively). There were no differences in the other corneal cell layers or in the status of the nerve fibres. The results demonstrate the ability of corneal confocal microscopy to evaluate an improvement in the basal epithelial cell layer of the cornea after autologous serum treatment in patients with dry eye disease. More studies with longer follow-up periods are needed to elucidate the suitability of corneal confocal microscopy to follow the effect of autologous serum treatment on nerve fibres or other corneal layers in dry eye disease patients. © 2016 Optometry Australia.

  18. [Endothelial keratopathy in pseudoexfoliation syndrome: quantitative and qualitative morphometry using automated video image analysis].

    PubMed

    Seitz, B; Müller, E E; Langenbucher, A; Kus, M M; Naumann, G O

    1995-09-01

    This prospective study intended to quantify and classify morphological changes of the corneal endothelium in pseudoexfoliation syndrome (PSX) after having tested reproducibility and validity of a new automated technique for analysing corneal endothelium. We used a contact specular microscope combined with a video camera (Tomey EM-1000) and a computer (IBM compatible PC, 486DX33) with suitable software (Tomey EM-1100, version 0.94). Video images of corneal endothelium (area: 0.312 mm2) are passed directly into the computer input by means of a frame grabber and are automatically processed. Missing or falsely recognized cell borders are corrected using the mouse. We examined 85 eyes with PSX and 33 healthy control eyes. At first, retest-stability and validity of the cell density measurements were assessed in the PSX-eyes. A qualitative analysis of the corneal endothelium followed. The cell density measurements showed a high retest-stability (reliability coefficient r = 0.974). The values of the automated method (2040 +/- 285 cells/mm2) and those of manual cell counting (2041 +/- 275 cells/mm2) did not differ significantly (p = 0.441). The mean difference was 3.1 +/- 2.4%. Comparing the 85 PSX-eyes (2052 +/- 264 cells/mm2) to the 33 control eyes (2372 +/- 276 cells/mm2), there was a significant reduction of cell density (p < 0.001). The cell density of the 69 PSX-eyes with glaucoma (2014 +/- 254 cells/mm2) was significantly lower than that of the 16 PSX-eyes without glaucoma (2214 +/- 251 cells/mm2) (p = 0.008). Eighty-five percent of the 85 PSX-eyes showed polymegalism, 77% pleomorphism; 68% had white deposits and 42% guttae. White deposits and guttae were significantly more frequent and more intensive in PSX-eyes than in control eyes. PSX-eyes with and those without glaucoma showed no significant differences concerning the four qualitative parameters. The automated method for analysing corneal endothelium quickly provides reproducible and valid results using the correction mode of the software. Semiquantitative analysis of qualitative parameters permits a more differentiated assessment of keratopathy in pseudoexfoliation syndrome than does mere consideration of endothelial cell density. Both evaluations are recommended to assess the risk of a diffuse endothelial decompensation before intraocular surgery.

  19. Variable-Size Bead Layer as Standard Reference for Endothelial Microscopes.

    PubMed

    Tufo, Simona; Prazzoli, Erica; Ferraro, Lorenzo; Cozza, Federica; Borghesi, Alessandro; Tavazzi, Silvia

    2017-02-01

    For morphometric analysis of the cell mosaic of corneal endothelium, checking accuracy and precision of instrumentation is a key step. In this study, a standard reference sample is proposed, developed to reproduce the cornea with its shape and the endothelium with its intrinsic variability in the cell size. A polystyrene bead layer (representing the endothelium) was deposited on a lens (representing the cornea). Bead diameters were 20, 25, and 30 μm (fractions in number 55%, 30%, and 15%, respectively). Bead density and hexagonality were simulated to obtain the expected true values and measured using a slit-lamp endothelial microscope applied to 1) a Takagi 700GL slit lamp at 40× magnification (recommended standard setup) and 2) a Takagi 2ZL slit lamp at 25× magnification. The simulation provided the expected bead density 2001 mm and hexagonality 47%. At 40×, density and hexagonality were measured to be 2009 mm (SD 93 mm) and 45% (SD 3%). At 25× on a different slit lamp, the comparison between measured and expected densities provided the factor 1.526 to resize the image and to use the current algorithms of the slit-lamp endothelial microscope for cell recognition. A variable-size polystyrene bead layer on a lens is proposed as a standard sample mimicking the real shape of the cornea and the variability of cell size and cell arrangement of corneal endothelium. The sample is suggested to evaluate accuracy and precision of cell density and hexagonality obtained by different endothelial microscopes, including a slit-lamp endothelial microscope applied to different slit lamps, also at different magnifications.

  20. [To Protect Corneal Transparency against Diseases].

    PubMed

    Usui, Tomohiko

    2016-03-01

    To protect corneal transparency, we tried to develop a new therapeutic strategy for corneal neovascularization, corneal scar, and TGFBI-related corneal dystrophy using nucleic acid drug. 1. The expression of angiopietin-like protein 2 (Angptl2) markedly increased in the neovascularized corneas compared to the normal cornea, and Angtpl2 was(a potent inducer of inflammatory corneal neovascularization. We have produced a single-stranded proline-modified short hairpin anti-Angptl2 ribonucleric acid interference (RNAi) molecule that is carried in a lipid nanoparticle for topical application. We have found this agent can penetrate all layers of the cornea. Angptl2 mRNA expression and corneal neovascularization were inhibited in a mouse alkari injury model by topical application of this agent. Thus, this modified RNAi agent is a new topical formulation for use against corneal neovascularization and scar. 2. Human umbilical vein endothelial cells (HUVECs) were cultured with human corneal keratocytes under serum-free conditions. We performed microarray gene-expression analysis in the coculture system and selected angiopoietin-like protein 7 (Angptl7). In vivo, intrastromal injections of an anti-Angptl7 RNAi agent into the avascular corneal stroma of mice resulted in the growth of blood vessels. Further, we examined the effects of Angptl7 on corneal nerves using culture rat trigeminal cells and this molecule had neurotrophic property on the cornea. Thus, Angpt17 is a unique molecule, which contain its bilateral character (anti-angiogenic and neurotrophic) in the cornea; an agonistic nucleic acid drug for Angptl7 may be a new therapeutic tool for protecting corneal transparency. 3. We examined local gene editing for TGFBI-related corneal dystrophy using CRISPR-Cas9 mediated homology directed repair (HDR). Cultured corneal keratocytes were obtained from a patient of R124H granular dystrophy. The R124H gene arrangement was corrected by a tranfection of guide RNA and HDR repair template single strand DNA in vitro. Thus, CRISPR-Cas9 medi-ated HDR could be a future radical treatment for TGFBI-related corneal dystrophy.

  1. [The relationship between corneal lymphangiogenesis and inflammation index after corneal alkali injury].

    PubMed

    Ling, Shi-qi; Li, Wei-hua; Xu, Jian-gang; Kuang, Wen-hui; Li, Chao-yang

    2010-11-01

    To discuss the relationship between corneal lymphangiogenesis and inflammation index (IF) in alkali burned corneas. Experimental research. Rat corneal hemangiogenesis and lymphangiogenesis were examined by 5'-nase-alkaline phosphatase (5'-NA-ALP) double enzyme-histochemistry and whole mount immunofluorescence at 1 day, 3 days, and 1, 2, 3, 4, 5, 6, 7, 8 weeks after alkaline burns, and the blood vessel counting (BVC) and the lymphatic vessel counting (LVC) were recorded. The state of corneal inflammation was observed under the slit lamp and evaluated by inflammation index (IF) grading at the same time. Then, the association of LVC with IF was examined. In addition, eleven human alkali burned corneas were obtained from 11 patients undergoing corneal transplantation in Zhongshan Ophthalmic Center from January 2005 to June 2008. Corneal lymphangiogenesis was examined by lymphatic vessel endothelial receptor (LYVE-1) immunohistochemistry. The significance of the differences in IF, inflammatory cells counting, burn history, and age between two groups was analyzed by using paired student's t-test. New lymphatic vessels were present in rat alkali burned corneas. Corneal lymphangiogenesis developed 3 days after alkaline burns, reached the top 2 weeks after the injury, then decreased gradually, and disappeared at the end of the 5th week. Corneal lymphatics occurred behind corneal inflammation, but disappeared before corneal inflammation and hemangiogenesis. LVC was strongly and positively correlated with IF (r = 0.572, P < 0.01) after corneal alkaline burns. Among eleven human alkali burned corneas, corneal lymphatic vessels were present in 3 corneas. Compared with the other 8 cases without corneal lymphangiogenesis, the scores of IF was significantly higher (t = 3.28, P < 0.05), the inflammatory cells counting dramatically increased (t = 2.42, P < 0.05), but the age decreased significantly (t = 2.62, P < 0.05). However, the difference in burn history between two groups was not significant (t = 1.28, P > 0.05). Corneal lymphangiogenesis develops after alkaline-burns and correlates closely with inflammation index.

  2. Ocular Biocompatibility of Nitinol Intraocular Clips

    PubMed Central

    Velez-Montoya, Raul; Erlanger, Michael

    2012-01-01

    Purpose. To evaluate the tolerance and biocompatibility of a preformed nitinol intraocular clip in an animal model after anterior segment surgery. Methods. Yucatan mini-pigs were used. A 30-gauge prototype injector was used to attach a shape memory nitinol clip to the iris of five pigs. Another five eyes received conventional polypropylene suture with a modified Seipser slip knot. The authors compared the surgical time of each technique. All eyes underwent standard full-field electroretinogram at baseline and 8 weeks after surgery. The animals were euthanized and eyes collected for histologic analysis after 70 days (10 weeks) postsurgery. The corneal thickness, corneal endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram parameters were compared between the groups. A two sample t-test for means and a P value of 0.05 were use for assessing statistical differences between measurements. Results. The injection of the nitinol clip was 15 times faster than conventional suturing. There were no statistical differences between the groups for corneal thickness, endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram measurements. Conclusions. The nitinol clip prototype is well tolerated and showed no evidence of toxicity in the short-term. The injectable delivery system was faster and technically less challenging than conventional suture techniques. PMID:22064995

  3. Characterization of rabbit limbal epithelial side population cells using RNA sequencing and single-cell qRT-PCR.

    PubMed

    Kameishi, Sumako; Umemoto, Terumasa; Matsuzaki, Yu; Fujita, Masako; Okano, Teruo; Kato, Takashi; Yamato, Masayuki

    2016-05-06

    Corneal epithelial stem cells reside in the limbus, a transitional zone between the cornea and conjunctiva, and are essential for maintaining homeostasis in the corneal epithelium. Although our previous studies demonstrated that rabbit limbal epithelial side population (SP) cells exhibit stem cell-like phenotypes with Hoechst 33342 staining, the different characteristics and/or populations of these cells remain unclear. Therefore, in this study, we determined the gene expression profiles of limbal epithelial SP cells by RNA sequencing using not only present public databases but also contigs that were created by de novo transcriptome assembly as references for mapping. Our transcriptome data indicated that limbal epithelial SP cells exhibited a stem cell-like phenotype compared with non-SP cells. Importantly, gene ontology analysis following RNA sequencing demonstrated that limbal epithelial SP cells exhibited significantly enhanced expression of mesenchymal/endothelial cell markers rather than epithelial cell markers. Furthermore, single-cell quantitative real-time reverse transcription polymerase chain reaction (qRT-PCR) demonstrated that the limbal epithelial SP population consisted of at least two immature cell populations with endothelial- or mesenchymal-like phenotypes. Therefore, our present results may propose the presence of a novel population of corneal epithelial stem cells distinct from conventional epithelial stem cells. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Corneal thickness: measurement and implications.

    PubMed

    Ehlers, Niels; Hjortdal, Jesper

    2004-03-01

    The thickness of the cornea was reported in more than 100-year-old textbooks on physiological optics (Helmholtz, Gullstrand). Physiological interest was revived in the 1950s by David Maurice, and over the next 50 years, this 'simple' biological parameter has been studied extensively. Several techniques for its measurement have been described and physiological and clinical significance have been studied. In this review, the different methods and techniques of measurement are briefly presented (optical, ultrasound). While the corneal thickness of many animals are the same over a considerable part of the surface, in the human cornea anterior and posterior curvature are not concentric giving rise to a problem of definition. Based on this the precision and accuracy of determining the central corneal thickness are discussed. Changes in corneal thickness reflects changes in function of the boundary layers, in particular the endothelial barrier. The absolute value of thickness is of importance for the estimation of IOP but also in diagnosis of corneal and systemic disorders. Finally it is discussed to what extent the thickness is a biometric parameter of significance, e.g. in the progression of myopia or in the development of retinal detachment.

  5. Development of mRuby2-Transfected C3H10T1/2 Fibroblasts for Musculoskeletal Tissue Engineering

    PubMed Central

    Yang, Yunzhi Peter

    2015-01-01

    Mouse C3H10T1/2 fibroblasts are multipotent, mesenchymal stem cell (MSC)-like progenitor cells that are widely used in musculoskeletal research. In this study, we have established a clonal population of C3H10T1/2 cells stably-transfected with mRuby2, an orange-red fluorescence reporter gene. Flow cytometry analysis and fluorescence imaging confirmed successful transfection of these cells. Cell counting studies showed that untransfected C3H10T1/2 cells and mRuby2-transfected C3H10T1/2 cells proliferated at similar rates. Adipogenic differentiation experiments demonstrated that untransfected C3H10T1/2 cells and mRuby2-transfected C3H10T1/2 cells stained positive for Oil Red O and showed increased expression of adipogenic genes including adiponectin and lipoprotein lipase. Chondrogenic differentiation experiments demonstrated that untransfected C3H10T1/2 cells and mRuby2-transfected C3H10T1/2 cells stained positive for Alcian Blue and showed increased expression of chondrogenic genes including aggrecan. Osteogenic differentiation experiments demonstrated that untransfected C3H10T1/2 cells and mRuby2-transfected C3H10T1/2 cells stained positive for alkaline phosphatase (ALP) as well as Alizarin Red and showed increased expression of osteogenic genes including alp, ocn and osf-1. When seeded on calcium phosphate-based ceramic scaffolds, mRuby2-transfected C3H10T1/2 cells maintained even fluorescence labeling and osteogenic differentiation. In summary, mRuby2-transfected C3H10T1/2 cells exhibit mRuby2 fluorescence and showed little-to-no difference in terms of cell proliferation and differentiation as untransfected C3H10T1/2 cells. These cells will be available from American Type Culture Collection (ATCC; CRL-3268™) and may be a valuable tool for preclinical studies. PMID:26407291

  6. Development of mRuby2-Transfected C3H10T1/2 Fibroblasts for Musculoskeletal Tissue Engineering.

    PubMed

    Ker, Dai Fei Elmer; Sharma, Rashmi; Wang, Evelyna Tsi Hsin; Yang, Yunzhi Peter

    2015-01-01

    Mouse C3H10T1/2 fibroblasts are multipotent, mesenchymal stem cell (MSC)-like progenitor cells that are widely used in musculoskeletal research. In this study, we have established a clonal population of C3H10T1/2 cells stably-transfected with mRuby2, an orange-red fluorescence reporter gene. Flow cytometry analysis and fluorescence imaging confirmed successful transfection of these cells. Cell counting studies showed that untransfected C3H10T1/2 cells and mRuby2-transfected C3H10T1/2 cells proliferated at similar rates. Adipogenic differentiation experiments demonstrated that untransfected C3H10T1/2 cells and mRuby2-transfected C3H10T1/2 cells stained positive for Oil Red O and showed increased expression of adipogenic genes including adiponectin and lipoprotein lipase. Chondrogenic differentiation experiments demonstrated that untransfected C3H10T1/2 cells and mRuby2-transfected C3H10T1/2 cells stained positive for Alcian Blue and showed increased expression of chondrogenic genes including aggrecan. Osteogenic differentiation experiments demonstrated that untransfected C3H10T1/2 cells and mRuby2-transfected C3H10T1/2 cells stained positive for alkaline phosphatase (ALP) as well as Alizarin Red and showed increased expression of osteogenic genes including alp, ocn and osf-1. When seeded on calcium phosphate-based ceramic scaffolds, mRuby2-transfected C3H10T1/2 cells maintained even fluorescence labeling and osteogenic differentiation. In summary, mRuby2-transfected C3H10T1/2 cells exhibit mRuby2 fluorescence and showed little-to-no difference in terms of cell proliferation and differentiation as untransfected C3H10T1/2 cells. These cells will be available from American Type Culture Collection (ATCC; CRL-3268™) and may be a valuable tool for preclinical studies.

  7. Irregular Astigmatism After Corneal Transplantation--Efficacy and Safety of Topography-Guided Treatment.

    PubMed

    Laíns, Inês; Rosa, Andreia M; Guerra, Marta; Tavares, Cristina; Lobo, Conceição; Silva, Maria F L; Quadrado, Maria J; Murta, Joaquim N

    2016-01-01

    To analyze the efficacy and safety of topography-guided photorefractive keratectomy (TG-PRK) to treat irregular astigmatism after corneal transplantation. This was a retrospective observational case series. Eyes with irregular astigmatism after penetrating keratoplasty treated with TG-PRK (Allegretto Wave Eye-Q) with the topography-guided customized ablation treatment protocol were included. All treatments had been planned to correct the topographic irregularities, as well as to reduce the refractive error after neutralizing the induced refractive change. Clinical records, treatment plan, and the examinations performed were reviewed and the following data were collected: corrected and uncorrected distance visual acuities; manifest refraction; topographic parameters, and corneal endothelial cell count. We included 31 eyes [30 patients; mean age 45.0 ± 13.4 (SD) years]. At the last postoperative follow-up (mean 9.2 ± 8.2 months), we observed a significant improvement in corrected (P = 0.001) and uncorrected distance visual acuities (P < 0.001). There was a gain of ≥1 uncorrected distance visual acuity line in 96.8% (n = 30) of the eyes. Similarly, the refractive parameters also improved (cylinder P < 0.001; spherical equivalent P = 0.002). At the last visit, 54.8% (n = 17) of the patients presented a spherical equivalent of ±1 D. The 3-mm topographic irregularity also decreased significantly (P < 0.001). There was no significant variation of the corneal endothelial cell count. This is the largest case series of TG-PRK to treat irregular astigmatism in postcorneal transplantation eyes. Our results confirm that TG-PRK is an efficient treatment, associated with significant improvements of both visual acuity and refractive parameters.

  8. Visual analysis of orthokeratology on myopia reduction for aviators

    NASA Astrophysics Data System (ADS)

    Mitsui, Iwane

    2005-04-01

    Ortho-K was indicated for sixty eyes of thirty aviators, twenty-one pilots and nine flight attendants, with age of 34.5 on the average. Uncorrected visual acuity (UCVA) was originally 20/30 or worse in all cases. The mean spherical equivalent (SE) was -3.69 Diopters (D). The same ophthalmologist designed full costumed reverse geometry Advanced Orthokeratology lenses for each patient. All the patients were followed at least two years wearing of Advanced Ortho-K lenses. The follow up examinations on auto-refraction, auto-keratometry, uncorrected and corrected visual acuity, intra-ocular pressure, corneal endothelial cells, corneal thickness and curve, and corneal shape were performed in the morning, 10am to 12am. 94% of the patients improved in UCVA up to 20/20 or better, 87% of them improved up to 20/15 or better, and 67% of them improved up to 20/10. The mean SEs improved to -1.90+/-1.00D during six months, -1.49+/-1.03D during one year, and -0.73+/-0.94D during two years. Astigmatism slightly increased by 0.38D on the average, however, it did not cause any serious problems for aviation tasks even during night. Intraocular pressure did not increase and corneal endothelial cells did not decrease. Other ophthalmologic examinations showed normal conditions and any complications were not observed throughout the period. Advanced Ortho-K was evaluated to be safe and effective enough for also aviators with myopia. It can be recommended one of the options of reduction of myopia for aviators. Evaluations on night vision and night glare are planned for further studies.

  9. SLC4A11 Prevents Osmotic Imbalance Leading to Corneal Endothelial Dystrophy, Deafness, and Polyuria*

    PubMed Central

    Gröger, Nicole; Fröhlich, Henning; Maier, Hannes; Olbrich, Andrea; Kostin, Sawa; Braun, Thomas; Boettger, Thomas

    2010-01-01

    Maintenance of ion concentration gradients is essential for the function of many organs, including the kidney, the cornea, and the inner ear. Ion concentrations and fluid content in the cornea are regulated by endothelial cells that separate the collagenous avascular corneal stroma from the anterior eye chamber. Failure to maintain correct ion concentrations leads to swelling and destruction of the cornea. In the inner ear, the stria vascularis is responsible for generating proper ion concentrations in the endolymph, which is essential for hearing. Mutations of SLC4A11 in humans lead to syndromes associated with corneal dystrophy and perceptive deafness. The molecular mechanisms underlying these symptoms are poorly understood, impeding therapeutic interventions. The ion transporter SLC4A11 mediates sodium-dependent transport of borate as well as flux of sodium and hydroxyl ions in vitro. Here, we show that SLC4A11 is expressed in the endothelial cells of the cornea where it prevents severe morphological changes of the cornea caused by increased sodium chloride concentrations in the stroma. In the inner ear, SLC4A11 is located in fibrocytes underlying the stria vascularis. Loss of SLC4A11 leads to morphological changes in the fibrocytes and deafness. We demonstrate that SLC4A11 is essential for the generation of the endocochlear potential but not for regulation of potassium concentrations in the endolymph. In the kidney, SLC4A11 is expressed in the thin descending limb of Henle loop. SLC4A11 is essential for urinary concentration, suggesting that SLC4A11 participates in the countercurrent multiplication that concentrates urine in the kidney medulla. PMID:20185830

  10. Interface Fluid Syndrome After Laser In Situ Keratomileusis (LASIK) Because of Fuchs Endothelial Dystrophy Reversed by Descemet Membrane Endothelial Keratoplasty (DMEK).

    PubMed

    Luceri, Salvatore; Baksoellah, Zainab; Ilyas, Abbas; Baydoun, Lamis; Melles, Gerrit R J

    2016-12-01

    To describe a case that developed "interface fluid syndrome" after previous laser in situ keratomileusis (LASIK) because of Fuchs endothelial dystrophy (FED), which was reversed by Descemet membrane endothelial keratoplasty (DMEK). A 58-year-old male patient presented with bilateral visual impairment owing to FED and visually significant cataract. Cataract surgery was carried out in both eyes followed by DMEK in his left eye. After cataract surgery, visual acuity did not improve sufficiently because corneal thickness increased and a fine cleft with interface fluid developed between the LASIK-flap and the residual stromal bed. After uneventful DMEK in his left eye, the fluid resolved within a week and visual acuity improved rapidly. This case demonstrates that "interface fluid syndrome" after LASIK caused by concomitant endothelial dysfunction may be reversed by DMEK allowing fast visual recovery.

  11. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty.

    PubMed

    Zafar, Andleeb; Aslanides, Ioannis M; Selimis, Vasileios; Tsoulnaras, Konstantinos I; Tabibian, David; Kymionis, George D

    2018-01-01

    We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.

  12. Management of corneal ectasia after LASIK with combined, same-day, topography-guided partial transepithelial PRK and collagen cross-linking: the athens protocol.

    PubMed

    Kanellopoulos, Anastasios John; Binder, Perry S

    2011-05-01

    To evaluate a series of patients with corneal ectasia after LASIK that underwent the Athens Protocol: combined topography-guided photorefractive keratectomy (PRK) to reduce or eliminate induced myopia and astigmatism followed by sequential, same-day ultraviolet A (UVA) corneal collagen cross-linking (CXL). Thirty-two consecutive corneal ectasia cases underwent transepithelial PRK (WaveLight ALLEGRETTO) immediately followed by CXL (3 mW/cm(2)) for 30 minutes using 0.1% topical riboflavin sodium phosphate. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, keratometry, central ultrasonic pachymetry, corneal tomography (Oculus Pentacam), and endothelial cell counts were analyzed. Mean follow-up was 27 months (range: 6 to 59 months). Twenty-seven of 32 eyes had an improvement in UDVA and CDVA of 20/45 or better (2.25 logMAR) at last follow-up. Four eyes showed some topographic improvement but no improvement in CDVA. One of the treated eyes required a subsequent penetrating keratoplasty. Corneal haze grade 2 was present in 2 eyes. Combined, same-day, topography-guided PRK and CXL appeared to offer tomographic stability, even after long-term follow-up. Only 2 of 32 eyes had corneal ectasia progression after the intervention. Seventeen of 32 eyes appeared to have improvement in UDVA and CDVA with follow-up >1.5 years. This technique may offer an alternative in the management of iatrogenic corneal ectasia. Copyright 2011, SLACK Incorporated.

  13. Anterior Chamber Air Bubble to Achieve Graft Attachment After DMEK: Is Bigger Always Better?

    PubMed

    Ćirković, Aleksandar; Beck, Christina; Weller, Julia M; Kruse, Friedrich E; Tourtas, Theofilos

    2016-04-01

    To analyze the influence of the size of the air bubble subsequent to Descemet membrane endothelial keratoplasty (DMEK) surgery on the rate of graft detachment and need for rebubbling, the incidence of pupillary block, and the observed endothelial cell loss. This is a single-center, retrospective, consecutive case series of 74 cases undergoing DMEK and fulfilling the inclusion criteria concerning the size of the air bubble at the end of surgery. Based on the medical records, patients were divided into 2 groups (n = 37, respectively). The first group had an air bubble with a volume of approximately 50% and the second group of approximately 80% of the anterior chamber (AC) volume, respectively. Patients who did not comply with instructions to remain in the supine position until complete resorption of AC air or cases in which difficulties in graft preparation (eg, radial breaks) occurred were excluded from data analysis. The central corneal thickness and endothelial cell density were measured 6 months after surgery. Ten of 37 patients (27.0%) in the 50% air bubble group and 3 of 37 patients (8.1%) in the 80% air bubble group needed 1 rebubbling procedure (P = 0.032). There was no difference between the groups after 6 months regarding endothelial cell density and central corneal thickness. No pupillary block was observed. Larger air bubbles of 80% anterior chamber volume decrease the risk of graft detachment after DMEK with no detrimental effect on the outcome and risk for pupillary block.

  14. Endothelial reaction to perforating and non-perforating excimer laser excisions in rabbits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koch, J.W.; Lang, G.K.; Naumann, G.O.

    1991-05-01

    With an ArF excimer laser (193 nm, 750 mJ/cm2, 20 Hz) and a special slit-mask system, perforating and non-perforating linear keratectomies were performed in 55 rabbit corneas with a follow-up from 1 hour to 6 months. Varying the pulse number according to ablation rate (0.8 micron/pulse) and corneal thickness, four linear radial excisions (3 mm length, 70 microns width) of increasing depth (70%, 80%, 90%, 100% perforation) were produced. The corneas were processed for light microscopy, scanning and transmission electron microscopy, and vital staining of the endothelium. Except for mild cell contact alterations and discrete single cell damage in themore » 90% deep excisions, no endothelial damage could be detected after non-perforating keratectomies. Minute (less than 20 microns) and small (20 to 100 microns maximal diameter) perforations induced cell enlargement, formation of pseudopodia, rosette-like figures, multi-nucleated giant cells, and ultimately uniform reformation of the cell pattern (1 hour to 7 days postoperatively). Larger excimer laser defects of Descemet's membrane (greater than 100 microns) were overgrown by dedifferentiated endothelial cells producing a new PAS-positive basement membrane. Vital staining revealed the complete and stable reorganization of the endothelium over these lesions within 6 months. The authors observations are similar to those reported on the endothelial repair process following other surgical manipulations (knife incisions, direct Nd:YAG-laser trauma) and support the applicability of excimer lasers for corneal trephination in patients.« less

  15. In situ ultrahigh-resolution optical coherence tomography characterization of eye bank corneal tissue processed for lamellar keratoplasty.

    PubMed

    Brown, Jamin S; Wang, Danling; Li, Xiaoli; Baluyot, Florence; Iliakis, Bernie; Lindquist, Thomas D; Shirakawa, Rika; Shen, Tueng T; Li, Xingde

    2008-08-01

    To use optical coherence tomography (OCT) as a noninvasive tool to perform in situ characterization of eye bank corneal tissue processed for lamellar keratoplasty. A custom-built ultrahigh-resolution OCT (UHR-OCT) was used to characterize donor corneal tissue that had been processed for lamellar keratoplasty. Twenty-seven donor corneas were analyzed. Four donor corneas were used as controls, whereas the rest were processed into donor corneal buttons for lamellar transplantation by using hand dissection, a microkeratome, or a femtosecond laser. UHR-OCT was also used to noninvasively characterize and monitor the viable corneal tissue immersed in storage medium over 3 weeks. The UHR-OCT captured high-resolution images of the donor corneal tissue in situ. This noninvasive technique showed the changes in donor corneal tissue morphology with time while in storage medium. The characteristics of the lamellar corneal tissue with each processing modality were clearly visible by UHR-OCT. The in situ characterization of the femtosecond laser-cut corneal tissue was noted to have more interface debris than shown by routine histology. The effects of the femtosecond laser microcavitation bubbles on the corneal tissue were well visualized at the edges of the lamellar flap while in storage medium. The results of our feasibility study show that UHR-OCT can provide superb, in situ microstructural characterization of eye bank corneal tissue noninvasively. The UHR-OCT interface findings and corneal endothelial disc thickness uniformity analysis are valuable information that may be used to optimize the modalities and parameters for lamellar tissue processing. The UHR-OCT is a powerful approach that will allow us to further evaluate the tissue response to different processing techniques for posterior lamellar keratoplasty. It may also provide information that can be used to correlate with postoperative clinical outcomes. UHR-OCT has the potential to become a routine part of tissue analysis for any eye bank or centers creating customized lamellar corneal tissue for transplantation.

  16. Differential expression of the Slc4 bicarbonate transporter family in murine corneal endothelium and cell culture.

    PubMed

    Shei, William; Liu, Jun; Htoon, Hla M; Aung, Tin; Vithana, Eranga N

    2013-01-01

    To characterize the relative expression levels of all the solute carrier 4 (Slc4) transporter family members (Slc4a1-Slc4a11) in murine corneal endothelium using real-time quantitative (qPCR), to identify further important members besides Slc4a11 and Slc4a4, and to explore how close to the baseline levels the gene expressions remain after cells have been subjected to expansion and culture. Descemet's membrane-endothelial layers of 8-10-week-old C57BL6 mice were stripped from corneas and used for both primary cell culture and direct RNA extraction. Total RNA (from uncultured cells as well as cultured cells at passages 2 and 7) was reverse transcribed, and the cDNA was used for real time qPCR using specific primers for all the Slc4 family members. The geNorm method was applied to determine the most stable housekeeping genes and normalization factor, which was calculated from multiple housekeeping genes for more accurate and robust quantification. qPCR analyses revealed that all Slc4 bicarbonate transporter family members were expressed in mouse corneal endothelium. Slc4a11 showed the highest expression, which was approximately three times higher than that of Slc4a4 (3.4±0.3; p=0.004). All Slc4 genes were also expressed in cultured cells, and interestingly, the expression of Slc4a11 in cultured cells was significantly reduced by approximately 20-fold (0.05±0.001; p=0.000001) in early passage and by approximately sevenfold (0.14±0.002; p=0.000002) in late passage cells. Given the known involvement of SLC4A4 and SLC4A11 in corneal dystrophies, we speculate that the other two highly expressed genes in the uncultured corneal endothelium, SLC4A2 and SLC4A7, are worthy of being considered as potential candidate genes for corneal endothelial diseases. Moreover, as cell culture can affect expression levels of Slc4 genes, caution and careful design of experiments are necessary when undertaking studies of Slc4-mediated ion transport in cultured cells.

  17. A comparative study of corneal incisions induced by diamond and steel knives and two ultraviolet radiations from an excimer laser.

    PubMed Central

    Marshall, J; Trokel, S; Rothery, S; Krueger, R R

    1986-01-01

    This paper reviews the potential role of excimer lasers in corneal surgery. The morphology of incisions induced by two wavelengths of excimer laser radiation, 193 nm and 248 nm, are compared with the morphology of incisions produced by diamond and steel knives. Analysis suggests that ablation induced by excimer laser results from highly localised photochemical reactions and that 193 nm is the optimal wavelength for surgery. The only significant complication of laser surgery is loss of endothelial cells when incisions are within 40 micron of Descemet's membrane. Images PMID:3013283

  18. Corneal edema and keratitis following selective laser trabeculoplasty.

    PubMed

    Liu, Erica Tan; Seery, Loren S; Arosemena, Analisa; Lamba, Tania; Chaya, Craig J

    2017-06-01

    To describe three cases of keratitis following Selective Laser Trabeculoplasty (SLT). Three females with a history of glaucoma presented with corneal edema, keratitis (endothelial, epithelial) and decreased visual acuity shortly after SLT. There was variable resolution of symptoms after starting treatment with oral antiherpetics and topical steroids. With the increase in usage of SLT as a treatment for glaucoma and subsequent reports of keratitis, it is imperative for ophthalmic surgeons to be aware of herpes simplex as a possible risk factor. Prompt treatment with antivirals and steroids can potentially prevent scarring and permanent damage to the cornea.

  19. A multicenter randomized controlled fellow eye trial of pulse-dosed difluprednate 0.05% versus prednisolone acetate 1% in cataract surgery.

    PubMed

    Donnenfeld, Eric D; Holland, Edward J; Solomon, Kerry D; Fiore, Jay; Gobbo, Anthony; Prince, Jessica; Sandoval, Helga P; Shull, Emily R; Perry, Henry D

    2011-10-01

    To compare the effects of 2 corticosteroids on corneal thickness and visual acuity after cataract surgery. Multicenter, randomized, contralateral-eye, double-masked trial. Fifty-two patients (104 eyes) underwent bilateral phacoemulsification. The first eye randomly received difluprednate 0.05% or prednisolone acetate 1%; the fellow eye received the alternative. Before surgery, 7 doses were administered over 2 hours; 3 additional doses were given after surgery, before discharge. For the remainder of the day, corticosteroids were administered every 2 hours, then 4 times daily during week 1 and twice daily during week 2. Corneal pachymetry, visual acuity, and corneal edema were evaluated before surgery and at days 1, 15, and 30 after surgery. Endothelial cell counts were evaluated before surgery and at 30 days after surgery. Retinal thickness was evaluated before surgery and at 15 and 30 days after surgery. Corneal thickness at day 1 was 33 μm less in difluprednate-treated eyes (P = .026). More eyes were without corneal edema in the difluprednate group than in the prednisolone group at day 1 (62% vs 38%, respectively; P = .019). Uncorrected and best-corrected visual acuity at day 1 were significantly better with difluprednate than prednisolone by 0.093 logMAR lines (P = .041) and 0.134 logMAR lines (P < .001), respectively. Endothelial cell density was 195.52 cells/mm(2) higher in difluprednate-treated eyes at day 30 (P < .001). Retinal thickness at day 15 was 7.74 μm less in difluprednate-treated eyes (P = .011). In this high-dose pulsed-therapy regimen, difluprednate reduced inflammation more effectively than prednisolone acetate, resulting in more rapid return of vision. Difluprednate was superior at protecting the cornea and reducing macular thickening after cataract surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Free radical development in phacoemulsification cataract surgery.

    PubMed

    Takahashi, Hiroshi

    2005-02-01

    Phacoemulsification and aspiration (PEA) has become the most popular cataract surgery, due to the establishment of safe surgical techniques and development of associated instruments. However, corneal endothelial damage still represents a serious complication, as excessive damage can lead to irreversible bullous keratopathy. In addition to causes such as mechanical or heat injuries, free radical formation due to ultrasound has been posited as another cause of corneal endothelium damage in PEA. Ultrasound in aqueous solution induces cavitation, directly causing water molecule disintegration and resulting in the formation of hydroxylradicals, the most potent of the reactive oxygen species. Considering the oxidative insult to endothelial cells caused by free radicals, their presence in the anterior chamber may represent one of the most harmful factors during these procedures. Indeed, some researchers have recently started to evaluate PEA from the perspective of oxidative stress. Conversely, the major ingredient in ophthalmic viscosurgical devices (OVDs), which are indispensable for maintaining the anterior chamber in PEA surgery, is sodium hyaluronate, a known free radical scavenger. OVDs can thus be expected to provide some anti-free radical effect during PEA procedures. In addition, since commercially available OVDs display different properties regarding retention in the anterior chamber during PEA, the anti-free radical effect of OVDs is likely to depend on behavior during irrigation and aspiration. The present study followed standard PEA procedures in an eye model and measured hydroxylradicals in the anterior chamber using electron spin resonance. The kinetics of free radical intensity and effects of several OVDs during clinical PEA were also demonstrated. These studies may be of significance in re-evaluating OVDs as a chemical protectant for corneal endothelium, since the OVD has thus far only been regarded as a physical barrier. In addition, many reports about corneal endothelium damage during PEA have been published, but objective evaluation of various damaging factors has been difficult. The present assay of free radicals in a simulation of clinical PEA offers the first method to quantitatively assess stress on the corneal endothelium.

  1. Changes of MK medium during storage of human cornea.

    PubMed Central

    Hasany, S M; Basu, P K

    1987-01-01

    By comparing the composition of McCarey-Kaufman (MK) medium before and after corneal storage we attempted to identify specific physiological changes in the medium as predictors of tissue damage. We also tried to determine if hydrocortisone (a lysosomal membrane stabiliser) added to the medium could reduce tissue damage during storage. Corneas (human and rabbit) were stored in the MK medium with and without hydrocortisone for 4 days at 4 degrees C. The water and nitrogen contents of the stored cornea were compared with those of the fresh cornea. The medium was analysed before and after corneal storage to determine the concentrations of glucose, protein, and amino acids as well as pH and osmolarity. Scanning electron microscopy (SEM) was used to estimate the degree of the corneal endothelial cell damage. The nitrogen contents and dry weights of the steroid treated and untreated stored corneas were similar to those of the fresh unstored cornea. The steroid treated cornea contained a lesser amount of water than the untreated cornea. The cornea stored in medium without steroid took up a greater amount of glucose from the medium than the cornea stored in medium with steroid. As compared with their concentrations in the fresh unused medium the concentrations of leucine, lysine, and glycine were lower and that of glutamic acid was higher in both the media used for corneal storage. However, the steroid treated storage medium as compared with the untreated storage medium had a greater reduction in the lowering of leucine, lysine, and glycine, and a lesser reduction in the increase of glutamic acid. Steroid treated medium also had a lesser amount of protein released from the stored cornea. Changes in the pH and osmolarity of the media before and after corneal storage were not remarkable. SEM showed that the endothelial cells of the cornea stored in the medium containing steroid were less damaged than those of the cornea stored in the medium without steroid. Images PMID:3620430

  2. Effects of androgen replacement therapy on cornea and tear function in men with idiopathic hypogonadotropic hypogonadism.

    PubMed

    Gokce, Gokcen; Hurmeric, Volkan; Mumcuoglu, Tarkan; Ozge, Gokhan; Basaran, Yalcin; Unal, Hilmi Umut; Bolu, Erol; Mutlu, Fatih Mehmet

    2015-05-01

    Idiopathic hypogonadotropic hypogonadism (IHH) is an endocrine disorder defined with the presence of typical clinical signs and symptoms plus laboratory confirmation of serum testosterone (T) levels lower than 300 ng/dl. Androgen replacement therapy (ART) is the first-step treatment of male IHH. To date, no clinical trial, which investigates the changes on corneal structure and tear function, of systemic ART in men have been published. The objective of this study was to investigate the effects of ART on cornea and tear function in patients with IHH. This prospective, interventional study was conducted at the Gulhane Military Medical Academy, Ankara, Turkey, a tertiary referral military hospital. Thirty-four eyes of 17 men with IHH patients were evaluated with Schirmer I test, ultrasound pachymeter, applanation tonometer and confocal microscopy. A Testosterone compound (Sustanon® 250 mg) was administered by intramuscular injection in the course of a 3-week period to induce puberty, and human chorionic gonadotropin (Pregnyl® 5000 IU) was administered twice weekly for 3 months to induce fertility. The patients were re-evaluated at the third month of the treatment. Main Outcome Measures were Schirmer score, central corneal thickness (CCT), intraocular pressure (IOP), endothelial cell density, coefficient of variation and cell shape. Schirmer scores showed similar results after the treatment compared to pre-treatment levels (p = 0.14). There was no statistically significant difference in CCT and IOP compared to baseline data (p = 0.96, p = 0.73, respectively), and no significant differences were found in corneal endothelial cell density, percentage of cell size variability or hexagonality (p = 0.83, p = 0.58, p = 0.64, respectively). This is the first study that investigates the effects of ART on corneal structure and tear function in men. ART seems to have no short-term effects on corneal structure and tear function. Further publications of larger, long-term and controlled studies are needed.

  3. Development of a reconstructed cornea from collagen-chondroitin sulfate foams and human cell cultures.

    PubMed

    Vrana, N Engin; Builles, Nicolas; Justin, Virginie; Bednarz, Jurgen; Pellegrini, Graziella; Ferrari, Barbara; Damour, Odile; Hulmes, David J S; Hasirci, Vasif

    2008-12-01

    To develop an artificial cornea, the ability to coculture the different cell types present in the cornea is essential. Here the goal was to develop a full-thickness artificial cornea using an optimized collagen-chondroitin sulfate foam, with a thickness close to that of human cornea, by coculturing human corneal epithelial and stromal cells and transfected human endothelial cells. Corneal extracellular matrix was simulated by a porous collagen/glycosaminoglycan-based scaffold seeded with stromal keratocytes and then, successively, epithelial and endothelial cells. Scaffolds were characterized for bulk porosity and pore size distribution. The performance of the three-dimensional construct was studied by histology, immunofluorescence, and immunohistochemistry. The scaffold had 85% porosity and an average pore size of 62.1 microm. Keratocytes populated the scaffold and produced a newly synthesized extracellular matrix as characterized by immunohistochemistry. Even though the keratocytes lost their CD34 phenotype marker, the absence of smooth muscle actin fibers showed that these cells had not differentiated into myofibroblasts. The epithelial cells formed a stratified epithelium and began basement membrane deposition. An endothelial cell monolayer beneath the foam was also apparent. These results demonstrate that collagen-chondroitin sulfate scaffolds are good substrates for artificial cornea construction with good resilience, long-term culture capability, and handling properties.

  4. The effects of Rho-associated kinase inhibitor Y-27632 on primary human corneal endothelial cells propagated using a dual media approach.

    PubMed

    Peh, Gary S L; Adnan, Khadijah; George, Benjamin L; Ang, Heng-Pei; Seah, Xin-Yi; Tan, Donald T; Mehta, Jodhbir S

    2015-03-16

    The global shortage of donor corneas has garnered extensive interest in the development of graft alternatives suitable for endothelial keratoplasty using cultivated primary human corneal endothelial cells (CECs). We have recently described a dual media approach for the propagation of human CECs. In this work, we characterize the effects of a Rho-kinase inhibitor Y-27632 on the cultivation of CECs propagated using the dual media culture system. Seventy donor corneas deemed unsuitable for transplantation were procured for this study. We assessed the use of Y-27632 for its effect at each stage of the cell culture process, specifically for cell attachment, cell proliferation, and during both regular passaging and cryopreservation. Lastly, comparison of donor-matched CEC-cultures expanded with or without Y-27632 was also performed. Our results showed that Y-27632 significantly improved the attachment and proliferation of primary CECs. A non-significant pro-survival effect was detected during regular cellular passage when CECs were pre-treated with Y-27632, an effect that became more evident during cryopreservation. Our study showed that the inclusion of Y-27632 was beneficial for the propagation of primary CECs expanded via the dual media approach, and was able to increase overall cell yield by between 1.96 to 3.36 fold.

  5. Mammalian cell models to advance our understanding of wound healing: a review.

    PubMed

    Vidmar, Jerneja; Chingwaru, Constance; Chingwaru, Walter

    2017-04-01

    Rapid and efficient healing of damaged tissue is critical for the restoration of tissue function and avoidance of tissue defects. Many in vitro cell models have been described for wound healing studies; however, the mechanisms that underlie the process, especially in chronic or complicated wounds, are not fully understood. The identification of cell culture systems that closely simulate the physiology of damaged tissue in vivo is necessary. We describe the cell culture models that have enhanced our understanding, this far, of the wound healing process or have been used in drug discovery. Cell cultures derived from the epithelium, including corneal, renal, intestinal (IEC-8 cells and IEC-6), skin epithelial cells (keratinocytes, fibroblasts, and multipotent mesenchymal stem cells), and the endothelium (human umbilical vein endothelial cells, primary mouse endothelial cells, endodermal stem cells, human mesenchymal stem cells, and corneal endothelial cells) have played a pivotal role toward our understanding of the mechanisms of wound healing. More studies are necessary to develop co-culture cell models which closely simulate the environment of a wound in vivo. Cell culture models are invaluable tools to promote our understanding of the mechanisms that regulate the wound healing process and provide a platform for drug discovery. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Risk factors for donor endothelial loss in eye bank-prepared posterior lamellar corneal tissue for descemet stripping automated endothelial keratoplasty.

    PubMed

    Liu, Yu-Chi; Alvarez Paraz, Carisa M; Cajucom-Uy, Howard Yu; Agahari, Djoni; Sethuraman, Selvam; Tan, Donald T-H; Mehta, Jodhbir S

    2014-07-01

    The aim of this study was to investigate donor, tissue, and precut procedure risk factors for endothelial cell density (ECD) loss in posterior lamellar corneal tissue preparation by an eye bank for Descemet stripping automated endothelial keratoplasty. A total of 259 corneoscleral rims precut by the Singapore Eye Bank from October 2011 to August 2013 were evaluated. Donor characteristics, tissue characteristics, and precut procedure parameters were analyzed. The mean donor age was 57.18 ± 11.35 years, and the mean cutting transition time was 4.16 ± 0.75 seconds. The mean ECD was 2826 ± 225 and 2787 ± 224 cells per square millimeter before and after precutting, respectively, with an average ECD change of -1.38% ± 3.28%. The precutting procedure failure rate was 1.2%. Mutivariate regression analysis showed that an older donor age, a higher ECD before cutting, and a slower cutting transition speed were significant factors. Corneas with an ECD >2800 cells per square millimeter before precutting, cutting transition time >5.5 seconds, and corneas with donor age >65 years were significantly more likely to have greater than 5% ECD loss after precutting (odds ratio, 6.42, 1.66, and 1.62; 95% confidence interval, 1.44-29.43, 1.45-2.72, and 1.66-5.82, respectively). Donor source, death-to-preservation time (range, 0.67-10.88 hours), death-to-precutting time (range, 0-7 days), and graft thickness (range, 43-232 μm) were not statistically significant factors. The ECD loss in the precut tissue prepared by the eye bank was very low. The risk factors identified provide better understanding of how to improve the quality and safety profiles when preparing graft tissue for Descemet stripping automated endothelial keratoplasty.

  7. Young donor-graft assisted endothelial keratoplasty (PDEK/DMEK) with epithelial debridement for chronic pseudophakic bullous keratopathy.

    PubMed

    Agarwal, Amar; Narang, Priya; Kumar, Dhivya A; Agarwal, Ashvin

    2017-10-01

    The aim of this study was to describe the applicability and report visual outcomes for the treatment of subepithelial fibrosis and anterior stromal scarring in cases of chronic pseudophakic bullous keratopathy (PBK) with epithelial debridement and endothelial keratoplasty (EK) (pre-Descemet endothelial keratoplasty [PDEK]; Descemet membrane endothelial keratoplasty [(DMEK]) using young donor tissue. Prospective, single-centre, interventional study. 6 cases with chronic PBK (> 1 year duration). Case 1 underwent PDEK with glued intraocular lens (IOL) as a single-stage procedure, whereas cases 2 and 3 underwent glued IOL followed by DMEK and PDEK, respectively, as a second-stage procedure. Cases 4 and 6 underwent PDEK, whereas case 5 underwent DMEK. Epithelial debridement was performed in all cases at the time of EK, and young donor grafts were used. The main outcome measures were best spectacle-corrected visual acuity, clearance of corneal scar and haze, central corneal thickness (CCT), specular microscopy, and endothelial cell count (ECC). Postoperatively, all cases demonstrated significant improvement in visual acuity. The mean value of depth of subepithelial haze was 121±71.7 µm and 25.3 ± 19.8 µm in the preoperative and postoperative periods, respectively (p = 0.028). At the 1-month follow-up, the mean preoperative CCT of 676 ± 92.7 µm was reduced to 534.6 ± 21.1µm. At the 6-month follow-up, the mean ECC loss resulting from the procedure was 36.5 ± 10.4%. EK with epithelial debridement performed for the treatment of chronic PBK resulted in significantly improved visual acuity to a functional level, with the clearance of subepithelial fibrosis and anterior stromal scar, in most patients. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  8. Diabetic corneal neuropathy.

    PubMed Central

    Schultz, R O; Peters, M A; Sobocinski, K; Nassif, K; Schultz, K J

    1983-01-01

    Corneal epithelial lesions can be found in approximately one-half of asymptomatic patients with diabetes mellitus. These lesions are transient and clinically resemble the keratopathy seen in staphylococcal keratoconjunctivitis. Staphylococcal organisms, however, can be isolated in equal percentages from diabetic patients without keratopathy. Diabetic peripheral neuropathy was found to be related to the presence of diabetic keratopathy after adjusting for age with analysis of covariance. The strongest predictor of both keratopathy and corneal fluorescein staining was vibration perception threshold in the toes (P less than 0.01); and the severity of keratopathy was directly related to the degree of diminution of peripheral sensation. Other predictors of keratopathy were: reduced tear breakup time (P less than 0.03), type of diabetes (P less than 0.01), and metabolic status as indicated by c-peptide fasting (P less than 0.01). No significant relationships were found between the presence of keratopathy and tear glucose levels, endothelial cell densities, corneal thickness measurements, the presence of S epidermidis, or with duration of disease. It is our conclusion that asymptomatic epithelial lesions in the nontraumatized diabetic cornea can occur as a manifestation of generalized polyneuropathy and probably represent a specific form of corneal neuropathy. Images FIGURE 1 FIGURE 2 FIGURE 3 PMID:6676964

  9. Outcomes of endothelial keratoplasty in pseudophakic corneal oedema: with or without Descemet's membrane stripping.

    PubMed

    Mohamed, Ashik; Ks, Anil Raj; Chaurasia, Sunita; Ramappa, Muralidhar

    2016-06-01

    To evaluate and compare outcomes of Descemet's stripping endothelial keratoplasty (DSEK) with non-DSEK (nDSEK) in pseudophakic corneal oedema (PCE). The study was a prospective, non-consecutive, comparative, interventional case series. Twenty-six patients with PCE were randomised into two groups. Group 1 comprised of those cases that had undergone conventional DSEK, and group 2 consisted of those that had nDSEK for PCE between 2010 and 2012. The data on demographics and clinical characteristics were collected from all patients. Any intraoperative and early and late postoperative complications were also noted. The primary outcome measure was postoperative functional success. Graft survival and complications were analysed as secondary outcomes. The median best-corrected visual acuities at 6 months postoperatively in groups 1 and 2 were 0.18 (IQR 0.10-0.30) and 0.44 (IQR 0.18-0.51), respectively (p=0.11). Corneal oedema cleared in all patients. During the early postoperative period, a patient in group 2 had lenticule detachment managed by rebubbling. nDSEK has outcomes similar to DSEK in PCE with advantages of decreased surgical time and avoidance of inadvertent pull on the posterior stromal fibres that may occur during Descemet's stripping. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. In vivo laser confocal microscopy findings of a cornea with osteogenesis imperfecta.

    PubMed

    Kobayashi, Akira; Higashide, Tomomi; Yokogawa, Hideaki; Yamazaki, Natsuko; Masaki, Toshinori; Sugiyama, Kazuhisa

    2014-01-01

    To report the in vivo laser confocal microscopy findings of a cornea with osteogenesis imperfecta (OI) with special attention to the abnormality of Bowman's layer and sub-Bowman's fibrous structures (K-structures). Two patients (67-year-old male and his 26-year-old son) with OI type I were included in this study. Slit lamp biomicroscopic and in vivo laser confocal microscopic examinations were performed for both patients. Central corneal thickness and central endothelial cell density were also measured. Although the corneas looked clear with normal endothelial density for both eyes in both patients, they were quite thin (386 μm oculus dexter (OD) (the right eye) and 384 μm oculus sinister (OS) (the left eye) in the father and 430 μm OD and 425 μm OS in the son). In both patients, slit lamp biomicroscopic and in vivo laser confocal microscopic examination showed similar results. Anterior corneal mosaics produced by rubbing the eyelid under fluorescein were completely absent in both eyes. In vivo laser confocal microscopy revealed an absent or atrophic Bowman's layer; a trace of a presumed Bowman's layer and/or basement membrane was barely visible with high intensity. Additionally, K-structures were completely absent in both eyes. The absence of K-structures and fluorescein anterior corneal mosaics strongly suggested an abnormality of Bowman's layer in these OI patients.

  11. The effect of an Ahmed glaucoma valve implant on corneal endothelial cell density in children with glaucoma secondary to uveitis.

    PubMed

    Kalinina Ayuso, Viera; Scheerlinck, Laura M; de Boer, Joke H

    2013-03-01

    To assess the effect of Ahmed glaucoma valve implants on corneal endothelial cell density (ECD) in children with uveitic glaucoma. Cross-sectional study. setting: Institutional. patientpopulation: Eighty eyes from 42 patients diagnosed with uveitis before the age of 16. Twenty-eight eyes had an Ahmed glaucoma valve implant because of secondary glaucoma. Fifty-two eyes without an implant served as controls. intervention orobservationprocedure(s): Corneal ECD was examined cross-sectionally using a noncontact specular microscope. Univariate and multivariate generalized estimating equations analyses with correction for paired eyes were performed. mainoutcomemeasure(s): Correlation of ECD with the presence of an Ahmed glaucoma valve implant and with the time following implantation. ECD was significantly lower in the Ahmed glaucoma valve group than in controls (2359 and 3088 cells/mm(2), respectively; P < .001) following an average of 3.5 years after Ahmed glaucoma valve implantation. Presence of an Ahmed glaucoma valve implant, previous intraocular surgery, age, duration of uveitis, and history of corneal touch by the implant tube were all significantly associated with decreased ECD. Following a multivariate analysis, presence of an Ahmed glaucoma valve implant (B = -340; adjusted P < .011) and older age (B = -58; adjusted P = .005) remained independently associated with decreased ECD. Within the implant group, the age-adjusted time interval following Ahmed glaucoma valve implantation was highly correlated with decreased ECD (B = -558, P < .001). Ahmed glaucoma valve implants in children with uveitic glaucoma are independently associated with decreased ECD, and this effect is associated with the time interval following Ahmed glaucoma valve implantation. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Oxygen therapy for corneal edema after cataract surgery.

    PubMed

    Sharifipour, Farideh; Panahi-Bazaz, Mahmoodreza; Idani, Esmaeil; Hajizadeh, Maryam; Saki, Azadeh

    2015-07-01

    To evaluate the effects of oxygen therapy on corneal edema after cataract surgery. Imam Khomeini Hospital, Ahvaz, Iran. Randomized controlled trial. Patients with severe corneal edema were randomized into 3 groups. Group 1 (control) received conventional therapy including topical sodium chloride, timolol, and betamethasone. Group 2 received the same therapy in addition to systemic normobaric oxygen at a flow rate of 10 L/min for 1 hour twice daily for 3 weeks. Group 3 received conventional therapy and transcorneal oxygen at a flow rate of 5 L/min for 1 hour twice daily for 3 weeks. Preoperative pachymetry and specular microscopy were performed. Pachymetry was performed 1, 3, 5, 7, 10, and 14 days postoperatively. At 1, 3 and 12 months, pachymetry and specular microscopy were performed. The study enrolled 45 patients. Preoperatively, there was no significant difference between the groups. Pachymetry was more than 1000 μm 1 day postoperatively in all patients. The preoperative pachymetry was restored in 14 days in Group 3 only. After 1 year, the endothelial cell count (ECC) was 1603 cells/mm(2), 1693 cells/mm(2), and 1911 cells/mm(2) with a loss of 37%, 32%, and 25% in Group 1, Group 2, and Group 3, respectively (P = .034, Groups 1 and 3). Group 3 had a higher ECC than the control group at 3 months (P = .037) and 1 year (P = .025). One patient in Group 1 and 1 patient in Group 2 developed bullous keratopathy. Transcorneal oxygen decreased corneal edema more rapidly than conventional and systemic oxygen therapies and preserved more endothelial cells than conventional therapy. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Involvement of cyclin D and p27 in cell proliferation mediated by ROCK inhibitors Y-27632 and Y-39983 during corneal endothelium wound healing.

    PubMed

    Okumura, Naoki; Nakano, Shinichiro; Kay, EunDuck P; Numata, Ryohei; Ota, Aya; Sowa, Yoshihiro; Sakai, Toshiyuki; Ueno, Morio; Kinoshita, Shigeru; Koizumi, Noriko

    2014-01-15

    To investigate the molecular mechanism of Rho-associated kinase (ROCK) inhibitors Y-27632 and Y-39983 on corneal endothelial cell (CEC) proliferation and their wound-healing effect. The expression of G1 proteins of the cell cycle and expression of phosphorylated Akt in monkey CECs (MCECs) treated with Y-27632 were determined by Western blotting. The effect of Y-39983 on the proliferation of MCECs and human CECs (HCECs) was evaluated by both Ki67 staining and incorporation of BrdU. As an in vivo study, Y-39983 was topically instilled in a corneal-endothelial partially injured rabbit model, and CEC proliferation was then evaluated. Investigation of the molecular mechanism of Y-27632 on CEC proliferation revealed that Y-27632 facilitated degradation of p27Kip1 (p27), and promoted the expression of cyclin D. When CECs were stimulated with Y-27632, a 1.7-fold increase in the activation of Akt was seen in comparison to the control after 1 hour. The presence of LY294002, the PI 3-kinase inhibitor, sustained the level of p27. When the efficacy of Y-39983 on cell proliferation was measured in a rabbit model, Y-39983 eye-drop instillation demonstrated rapid wound healing in a concentration range of 0.095 to 0.95 mM, whereas Y-27632 demonstrated rapid wound healing in a concentration range of 3 to 10 mM. These findings show that ROCK inhibitors employ both cyclin D and p27 via PI 3-kinase signaling to promote CEC proliferation, and that Y-39983 may be a more potent agent than Y-27632 for facilitating corneal endothelium wound healing.

  14. Comparison of corneal endothelial image analysis by Konan SP8000 noncontact and Bio-Optics Bambi systems.

    PubMed

    Benetz, B A; Diaconu, E; Bowlin, S J; Oak, S S; Laing, R A; Lass, J H

    1999-01-01

    Compare corneal endothelial image analysis by Konan SP8000 and Bio-Optics Bambi image-analysis systems. Corneal endothelial images from 98 individuals (191 eyes), ranging in age from 4 to 87 years, with a normal slit-lamp examination and no history of ocular trauma, intraocular surgery, or intraocular inflammation were obtained by the Konan SP8000 noncontact specular microscope. One observer analyzed these images by using the Konan system and a second observer by using the Bio-Optics Bambi system. Three methods of analyses were used: a fixed-frame method to obtain cell density (for both Konan and Bio-Optics Bambi) and a "dot" (Konan) or "corners" (Bio-Optics Bambi) method to determine morphometric parameters. The cell density determined by the Konan fixed-frame method was significantly higher (157 cells/mm2) than the Bio-Optics Bambi fixed-frame method determination (p<0.0001). However, the difference in cell density, although still statistically significant, was smaller and reversed comparing the Konan fixed-frame method with both Konan dot and Bio-Optics Bambi comers method (-74 cells/mm2, p<0.0001; -55 cells/mm2, p<0.0001, respectively). Small but statistically significant morphometric analyses differences between Konan and Bio-Optics Bambi were seen: cell density, +19 cells/mm2 (p = 0.03); cell area, -3.0 microm2 (p = 0.008); and coefficient of variation, +1.0 (p = 0.003). There was no statistically significant difference between these two methods in the percentage of six-sided cells detected (p = 0.55). Cell densities measured by the Konan fixed-frame method were comparable with Konan and Bio-Optics Bambi's morphometric analysis, but not with the Bio-Optics Bambi fixed-frame method. The two morphometric analyses were comparable with minimal or no differences for the parameters that were studied. The Konan SP8000 endothelial image-analysis system may be useful for large-scale clinical trials determining cell loss; its noncontact system has many clinical benefits (including patient comfort, safety, ease of use, and short procedure time) and provides reliable cell-density calculations.

  15. [Ursolic acid inhibits corneal graft rejection following orthotopic allograft transplantation in rats].

    PubMed

    Wang, Bo; Wu, Jing; Ma, Ming; Li, Ping-Ping; Yu, Jian

    2015-04-01

    To investigate the effects of ursolic acid on corneal graft rejection in a rat model of othotopic corneal allograft transplantation. Forty-eight recipient Wistar rats were divided into normal control group with saline treatment (group A), autograft group with saline treatment (group B), SD rat allograft group with saline treatment (group C), and SD rat allograft group with intraperitoneal ursolic acid (UA) treatment group (group D). The rats received saline or UC (20 mg·kg(-1)·d(-1)) treatment for 12 days following othotopic graft transplantation. The grafts were evaluated using the Larkin corneal rejection rating system, and the graft survival was assessed with Kaplan-Meier analysis. On day 14, the grafts were harvested for histological examination, Western blotting, and assessment of expressions of interlukin-2 (IL-2), interferon-γ (IFN-γ), nuclear transcription factor-κB (NF-κB) p65, vascular endothelial growth factor (VEGF) and intercellular adhesion molecule-1 (ICAM-1). The allograft survival was significantly longer in group D than in group C (29.12±9.58 vs 9.67±2.16 days, P<0.05). UC treatment obviously reduced the expression levels of IL-2, IFN-γ, NF-κBp65, ICAM-1 and VEGF and increased inhibitory kappa B alpha (IκB-α) expression in the grafts, where no obvious inflammatory cell infiltration or corneal neovascularization was found. As a NF-κB inhibitor, ursolic acid can prevent corneal neovascularization and corneal allograft rejection to promote graft survival in rats following orthotopic corneal allograft transplantation.

  16. Human tears reveal insights into corneal neovascularization.

    PubMed

    Zakaria, Nadia; Van Grasdorff, Sigi; Wouters, Kristien; Rozema, Jos; Koppen, Carina; Lion, Eva; Cools, Nathalie; Berneman, Zwi; Tassignon, Marie-José

    2012-01-01

    Corneal neovascularization results from the encroachment of blood vessels from the surrounding conjunctiva onto the normally avascular cornea. The aim of this study is to identify factors in human tears that are involved in development and/or maintenance of corneal neovascularization in humans. This could allow development of diagnostic tools for monitoring corneal neovascularization and combination monoclonal antibody therapies for its treatment. In an observational case-control study we enrolled a total of 12 patients with corneal neovascularization and 10 healthy volunteers. Basal tears along with reflex tears from the inferior fornix, superior fornix and using a corneal bath were collected along with blood serum samples. From all patients, ocular surface photographs were taken. Concentrations of the pro-angiogenic cytokines interleukin (IL)-6, IL-8, Vascular Endothelial Growth Factor (VEGF), Monocyte Chemoattractant Protein 1 (MCP-1) and Fas Ligand (FasL) were determined in blood and tear samples using a flow cytometric multiplex assay. Our results show that the concentration of pro-angiogenic cytokines in human tears are significantly higher compared to their concentrations in serum, with highest levels found in basal tears. Interestingly, we could detect a significantly higher concentration of IL- 6, IL-8 and VEGF in localized corneal tears of patients with neovascularized corneas when compared to the control group. This is the first study of its kind demonstrating a significant difference of defined factors in tears from patients with neovascularized corneas as compared to healthy controls. These results provide the basis for future research using animal models to further substantiate the role of these cytokines in the establishment and maintenance of corneal neovascularization.

  17. Human Tears Reveal Insights into Corneal Neovascularization

    PubMed Central

    Wouters, Kristien; Rozema, Jos; Koppen, Carina; Lion, Eva; Cools, Nathalie; Berneman, Zwi; Tassignon, Marie-José

    2012-01-01

    Corneal neovascularization results from the encroachment of blood vessels from the surrounding conjunctiva onto the normally avascular cornea. The aim of this study is to identify factors in human tears that are involved in development and/or maintenance of corneal neovascularization in humans. This could allow development of diagnostic tools for monitoring corneal neovascularization and combination monoclonal antibody therapies for its treatment. In an observational case-control study we enrolled a total of 12 patients with corneal neovascularization and 10 healthy volunteers. Basal tears along with reflex tears from the inferior fornix, superior fornix and using a corneal bath were collected along with blood serum samples. From all patients, ocular surface photographs were taken. Concentrations of the pro-angiogenic cytokines interleukin (IL)-6, IL-8, Vascular Endothelial Growth Factor (VEGF), Monocyte Chemoattractant Protein 1 (MCP-1) and Fas Ligand (FasL) were determined in blood and tear samples using a flow cytometric multiplex assay. Our results show that the concentration of pro-angiogenic cytokines in human tears are significantly higher compared to their concentrations in serum, with highest levels found in basal tears. Interestingly, we could detect a significantly higher concentration of IL- 6, IL-8 and VEGF in localized corneal tears of patients with neovascularized corneas when compared to the control group. This is the first study of its kind demonstrating a significant difference of defined factors in tears from patients with neovascularized corneas as compared to healthy controls. These results provide the basis for future research using animal models to further substantiate the role of these cytokines in the establishment and maintenance of corneal neovascularization. PMID:22590547

  18. Corneal Transplantation in Auckland, New Zealand, 1999-2009: Indications, Patient Characteristics, Ethnicity, Social Deprivation, and Access to Services.

    PubMed

    Crawford, Alexandra Z; McKelvie, James; Craig, Jennifer P; McGhee, Charles N J; Patel, Dipika V

    2017-05-01

    To analyze characteristics and indications for corneal transplantation in patients undergoing penetrating, lamellar, and endothelial keratoplasty in Auckland, New Zealand (NZ). Corneal transplantation data from the NZ National Eye Bank and hospital records of corneal transplant recipients in the Auckland region from January 1, 2000, to December 31, 2009, were collated. Patient demographics, preoperative diagnosis, indication, ocular and medical history, visual acuity, deprivation index, and access to transplantation surgery were analyzed. A total of 941 corneal transplants involving 770 patients were included for analysis. Mean age was 46 years. Age and ethnicity varied according to the transplant indication. A male preponderance and disproportionally high rates of Māori and Pacific ethnicity with a mean age of 30 years were observed in transplants for keratoconus. A total of 67.2% of corneal transplants were completed in the public health system and were associated with higher levels of deprivation than those completed in private facilities. Preoperative visual acuity varied according to the transplant type and indication. The most common clinical indication for corneal transplantation was keratoconus (41.3%), followed by repeat transplantation (21.0%). There was no significant change in the relative proportion of transplant indications in any year over the duration of this study (P = 0.41). A contralateral corneal transplant was present in 24.4% and glaucoma in 12.8% of penetrating keratoplasty recipients. Keratoconus is the leading indication for corneal transplantation in Auckland, NZ, and involves a disproportionately high rate of Māori and Pacific transplant recipients with a male preponderance and comparatively low mean age at the time of surgery.

  19. In vivo architectural analysis of 3.2 mm clear corneal incisions for phacoemulsification using optical coherence tomography.

    PubMed

    Torres, Luis F; Saez-Espinola, Fidelia; Colina, Juner M; Retchkiman, Myriam; Patel, Milan R; Agurto, Ricardo; Garcia, Gerardo; Diaz, Jose L; Huang, David; Schanzlin, David J; Chayet, Arturo S

    2006-11-01

    To analyze in vivo the architecture of clear corneal incisions (CCIs) for phacoemulsification using optical coherence tomography (OCT). Anterior Segment Department, Asociacion Para Evitar la Ceguera en Mexico, Hospital Dr Luis Sanchez Bulnes, Mexico. A prospective masked study analyzed 20 unsutured CCIs placed superiorly and created in a uniplanar fashion with a 3.2 mm slit-angled metal keratome. All wounds were evaluated with a retinal OCT model 1, 3, and 30 days postoperatively. Intraocular pressure (IOP) and incision leakage were checked. The architecture was described according to the angle of incidence, apposition of the epithelial and endothelial margins, and wound sealing. No leakage was detected. The angle varied from 33 to 85 degrees; angles greater than 75 degrees were done by a surgeon in training. Wound apposition at the epithelial margin was achieved in all cases. In contrast, imperfect apposition of the endothelial margin was seen in 45% of incisions on day 1 and in 15% on day 30. Incomplete sealing of the wound was seen by OCT in 25% of cases at 24 hours and persisted in 10% of all cases at 1 month. This gaping occurred on the endothelial side and never translated to the epithelial margin. No statistical correlation was found between gaping and the angle of the incision, IOP variations, or surgeon experience. Although in vivo CCIs caused minor anatomic imperfections, they were clinically stable independent of incision angle, IOP variation, and surgeon experience. Incision stability may be related to careful wound construction, epithelial viability, stromal edema, and efficient endothelial pumping.

  20. Evaluation of endothelial mucin layer thickness after phacoemulsification with next generation ophthalmic irrigating solution.

    PubMed

    Ghate, Deepta A; Holley, Glenn; Dollinger, Harli; Bullock, Joseph P; Markwardt, Kerry; Edelhauser, Henry F

    2008-10-01

    To evaluate human corneal endothelial mucin layer thickness and ultrastructure after phacoemulsification and irrigation-aspiration with either next generation ophthalmic irrigating solution (NGOIS) or BSS PLUS. Paired human corneas were mounted in an artificial anterior chamber, exposed to 3 minutes of continuous ultrasound (US) at 80% power using the Alcon SERIES 20000 LEGACY surgical system (n = 9) or to 2 minutes of pulsed US at 50% power, 50% of the time at 20 pps using the Alcon INFINITI Vision System (n = 5), and irrigated with 250 mL of either NGOIS or BSS PLUS. A control group of paired corneas did not undergo phacoemulsification or irrigation-aspiration (n = 5). Corneas were divided and fixed for mucin staining or transmission electron microscopy. Mucin layer thickness was measured on the transmission electron microscopy prints. The mucin layer thickness in the continuous phaco group was 0.77 +/- 0.02 microm (mean +/- SE) with NGOIS and 0.51 +/- 0.01 microm with BSS PLUS (t test, P < 0.001). The mucin layer thickness in the pulsed phaco group was 0.79 +/- 0.02 microm with NGOIS and 0.54 +/- 0.01 microm with BSS PLUS (P < 0.001). The mucin layer thickness in the untreated control group was 0.72 +/- 0.02 microm. The endothelial ultrastructure was normal in all corneas. In this in vitro corneal model, NGOIS, due to its lower surface tension and higher viscosity, preserved endothelial mucin layer thickness better than BSS PLUS with both the INFINITI Vision System (pulsed US) and the LEGACY surgical system (continuous US).

  1. A Mathematical Model to Predict Endothelial Cell Density Following Penetrating Keratoplasty With Selective Dropout From Graft Failure

    PubMed Central

    Riddlesworth, Tonya D.; Kollman, Craig; Lass, Jonathan H.; Patel, Sanjay V.; Stulting, R. Doyle; Benetz, Beth Ann; Gal, Robin L.; Beck, Roy W.

    2014-01-01

    Purpose. We constructed several mathematical models that predict endothelial cell density (ECD) for patients after penetrating keratoplasty (PK) for a moderate-risk condition (principally Fuchs' dystrophy or pseudophakic/aphakic corneal edema). Methods. In a subset (n = 591) of Cornea Donor Study participants, postoperative ECD was determined by a central reading center. Various statistical models were considered to estimate the ECD trend longitudinally over 10 years of follow-up. A biexponential model with and without a logarithm transformation was fit using the Gauss-Newton nonlinear least squares algorithm. To account for correlated data, a log-polynomial model was fit using the restricted maximum likelihood method. A sensitivity analysis for the potential bias due to selective dropout was performed using Bayesian analysis techniques. Results. The three models using a logarithm transformation yield similar trends, whereas the model without the transform predicts higher ECD values. The adjustment for selective dropout turns out to be negligible. However, this is possibly due to the relatively low rate of graft failure in this cohort (19% at 10 years). Fuchs' dystrophy and pseudophakic/aphakic corneal edema (PACE) patients had similar ECD decay curves, with the PACE group having slightly higher cell densities by 10 years. Conclusions. Endothelial cell loss after PK can be modeled via a log-polynomial model, which accounts for the correlated data from repeated measures on the same subject. This model is not significantly affected by the selective dropout due to graft failure. Our findings warrant further study on how this may extend to ECD following endothelial keratoplasty. PMID:25425307

  2. Corneal incision architecture after IOL implantation with three different injectors: an environmental scanning electron microscopy study.

    PubMed

    Mencucci, Rita; Favuzza, Eleonora; Salvatici, Maria Cristina; Spadea, Leopoldo; Allen, David

    2018-02-01

    To evaluate by Environmental Scanning Electron Microscopy (ESEM) the corneal incision architecture after intraocular lens (IOL) implantation in pig eyes, using manual, automated injectors or preloaded delivery systems. Twenty-four pig eyes underwent IOL implantation in the anterior chamber using three different injectors: manual (Monarch III) (n = 8), automated (AutoSert) (n = 8), or a preloaded system (UltraSert) (n = 8). Acrysof IQ IOLs, 21 Dioptres (D) (n = 12) and 27D (n = 12), were implanted through 2.2 mm clear corneal incisions. Incision width was measured using corneal calipers. The endothelial side of the incision was analyzed with ESEM. In each group, the final size of the corneal wound after IOL implantation, measured by calipers, was 2.3-2.4 mm. The incision architecture resulted more irregular in the Monarch group compared with the other injectors. In every group the 27D IOL-implanted specimens showed more alterations than in 21D IOL-implanted samples, and this was less evident in the UltraSert group. The Descemet tear length was higher in the Monarch group than AutoSert and UltraSert group. The automated and preloaded delivery systems provided a good corneal incision architecture; after high-power IOL implantation the incisions were more regular and less damaged with the preloaded system than with the other devices.

  3. Glaucoma and Corneal Transplant Procedures

    PubMed Central

    Al-Mahmood, Ammar M.; Al-Swailem, Samar A.; Edward, Deepak P.

    2012-01-01

    Glaucoma after corneal transplantation is a leading cause of ocular morbidity after penetrating keratoplasty. The incidence reported is highly variable and a number of etiologic factors have been identified. A number of treatment options are available; surgical intervention for IOP control is associated with a high incidence of graft failure. IOP elevation is less frequently seen following deep anterior lamellar keratoplasty. Descemet's striping-automated endothelial keratoplasty is also associated with postprocedure intraocular pressure elevation and secondary glaucoma and presents unique surgical challenges in patients with preexisting glaucoma surgeries. Glaucoma exists in up to three-quarters of patients who undergo keratoprosthesis surgery and the management if often challenging. The aim of this paper is to highlight the incidence, etiology, and management of glaucoma following different corneal transplant procedures. It also focuses on the challenges in the diagnosis of glaucoma and intraocular pressure monitoring in this group of patients. PMID:22315661

  4. Assessment of the Dutch organ-culture system of corneal preservation within the Eye Bank of South Australia.

    PubMed

    Williams, K A; Noack, L M; Alfrich, S J; Danz, R; Erickson, S A; Coster, D J

    1988-02-01

    Thirteen per cent of all corneas harvested by the Eye Bank of South Australia during 1986 were discarded because storage time in McCarey-Kaufman medium exceeded four days. We have therefore examined the suitability of the Dutch method of long-term corneal storage for our purposes. Twenty-two human corneas that had been discarded from the Eye Bank were assessed using the trypan blue-sucrose staining technique, and then placed into long-term storage for 15 to 17 days. They were then reassessed by vital dye staining before permanent flat-mounts were prepared for silver staining of the endothelium. A good correlation (albeit subjective) was found between the non-destructive and destructive techniques of endothelial cell assessment. Those corneas that failed to survive organ culture storage were easily detected. The Dutch system of corneal preservation and post-storage assessment seems well-suited to Australian eye-banking.

  5. Glutaminolysis is Essential for Energy Production and Ion Transport in Human Corneal Endothelium.

    PubMed

    Zhang, Wenlin; Li, Hongde; Ogando, Diego G; Li, Shimin; Feng, Matthew; Price, Francis W; Tennessen, Jason M; Bonanno, Joseph A

    2017-02-01

    Corneal endothelium (CE) is among the most metabolically active tissues in the body. This elevated metabolic rate helps the CE maintain corneal transparency by its ion and fluid transport properties, which when disrupted, leads to visual impairment. Here we demonstrate that glutamine catabolism (glutaminolysis) through TCA cycle generates a large fraction of the ATP needed to maintain CE function, and this glutaminolysis is severely disrupted in cells deficient in NH 3 :H + cotransporter Solute Carrier Family 4 Member 11 (SLC4A11). Considering SLC4A11 mutations leads to corneal endothelial dystrophy and sensorineural deafness, our results indicate that SLC4A11-associated developmental and degenerative disorders result from altered glutamine catabolism. Overall, our results describe an important metabolic mechanism that provides CE cells with the energy required to maintain high level transport activity, reveal a direct link between glutamine metabolism and developmental and degenerative neuronal diseases, and suggest an approach for protecting the CE during ophthalmic surgeries. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Cornea and anterior eye assessment with slit lamp biomicroscopy, specular microscopy, confocal microscopy, and ultrasound biomicroscopy

    PubMed Central

    Martin, Raul

    2018-01-01

    Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple, and several devices and technologies show signs that help in identification of different diseases thereby, helping in diagnosis, management, and follow-up of patients. The purpose of this review is to present and update readers on the evaluation of cornea and ocular surface. This first part reviews a description of slit lamp biomicroscopy (SLB), endothelial specular microscopy, confocal microscopy, and ultrasound biomicroscopy examination techniques and the second part describes the corneal topography and tomography, providing up-to-date information on the clinical recommendations of these techniques in eye care practice. Although the SLB is a traditional technique, it is of paramount importance in clinical diagnosis and compulsory when an eye test is conducted in primary or specialist eye care practice. Different techniques allow the early diagnosis of many diseases, especially when clinical signs have not yet become apparent and visible with SLB. These techniques also allow for patient follow-up in several clinical conditions or diseases, facilitating clinical decisions and improving knowledge regarding the corneal anatomy. PMID:29380757

  7. Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices

    PubMed Central

    Khan, Salman Nasir; Shiakolas, Panos S.; Mootha, Venkateswara Vinod

    2015-01-01

    This review study provides information regarding the construction, design, and use of six commercially available endothelial allograft insertion devices applied for Descemet's stripping automated endothelial keratoplasty (DSAEK). We also highlight issues being faced in DSAEK and discuss the methods through which medical devices such as corneal inserters may alleviate these issues. Inserter selection is of high importance in the DSAEK procedure since overcoming the learning curve associated with the use of an insertion device is a time and energy consuming process. In the present review, allograft insertion devices were compared in terms of design, construction material, insertion technique, dimensions, incision requirements and endothelial cell loss to show their relative merits and capabilities based on available data in the literature. Moreover, the advantages/disadvantages of various insertion devices used for allograft insertion in DSAEK are reviewed and compared. The information presented in this review can be utilized for better selection of an insertion device for DSAEK. PMID:27051492

  8. Nomogram to Predict Graft Thickness in Descemet Stripping Automated Endothelial Keratoplasty: An Eye Bank Study.

    PubMed

    Bae, Steven S; Menninga, Isaac; Hoshino, Richard; Humphreys, Christine; Chan, Clara C

    2018-06-01

    The purpose of this study was to develop a nomogram to predict postcut thickness of corneal grafts prepared at an eye bank for Descemet stripping automated endothelial keratoplasty (DSAEK). Retrospective chart review was performed of DSAEK graft preparations by 3 experienced technicians from April 2012 to May 2017 at the Eye Bank of Canada-Ontario Division. Variables collected included the following: donor demographics, death-to-preservation time, death-to-processing time, precut tissue thickness, postcut tissue thickness, microkeratome head size, endothelial cell count, cut technician, and rate of perforation. Linear regression models were generated for each microkeratome head size (300 and 350 μm). A total of 780 grafts were processed during the study period. Twelve preparation attempts resulted in perforation (1.5%) and were excluded. Mean precut tissue thickness was 510 ± 49 μm (range: 363-670 μm). Mean postcut tissue thickness was 114 ± 22 μm (range: 57-193 μm). Seventy-nine percent (608/768) of grafts were ≤130 μm. The linear regression models included precut thickness and donor age, which were able to predict the thickness to within 25 μm 80% of the time. We report a nomogram to predict thickness of DSAEK corneal grafts prepared in an eye bank setting, which was accurate to within 25 μm 80% of the time. Other eye banks could consider performing similar analyses.

  9. Learning DMEK From YouTube.

    PubMed

    McKee, Hamish D; Jhanji, Vishal

    2017-12-01

    To evaluate the outcomes of the first cases of Descemet membrane endothelial keratoplasty (DMEK) performed by an anterior segment surgeon, learning the procedure, including graft preparation, primarily from watching YouTube videos. DMEK surgery was not learned during fellowship training; there was no attendance at DMEK courses, no witnessing of live surgery, and no supervision by an experienced DMEK surgeon. All graft tissue was prepared by the surgeon on the day of surgery. This is a retrospective review of the 3-month postoperative results of the first 40 consecutive cases. The success rate of graft preparation, intraoperative and postoperative complications, spectacle-corrected visual acuity, endothelial cell density, and central corneal thickness were evaluated. Grafts were successfully prepared in all cases with no loss of donor tissue. DMEK surgery was successful in 39 of 40 eyes with the one failure occurring in a vitrectomized eye without an intact iris-lens diaphragm. Spectacle-corrected visual acuity was ≥6/6 in 23 of the 25 eyes without comorbidity. Mean endothelial cell density was 1515 (±474) cells/mm. Mean central corneal thickness decreased from 624 (±40) μm preoperatively to 513 (±34) μm postoperatively. Although formal training is desirable, good results can be obtained by an anterior segment surgeon learning DMEK, including graft preparation, without it. DMEK should no longer be considered a procedure with a long learning curve in routine cases.

  10. Hyperpolarization of the plasma membrane potential provokes reorganization of the actin cytoskeleton and increases the stability of adherens junctions in bovine corneal endothelial cells in culture.

    PubMed

    Nin, Verónica; Hernández, Julio A; Chifflet, Silvia

    2009-12-01

    In previous works we showed that the depolarization of the plasma membrane potential (PMP) determines a reorganization of the cytoskeleton of diverse epithelia in culture, consisting mainly of a reallocation of peripheral actin toward the cell center, ultimately provoking intercellular disruption. In view of this evidence, we explored in this study the possible effects of membrane potential hyperpolarization on the cytoskeletal organization and adherens junction (AJ) morphology and the stability of confluent bovine corneal endothelial cells in culture. For this purpose, hyperpolarization was achieved by substitution of extracellular sodium by nondiffusible cations or via the incorporation of valinomycin to the control solution. Actin compactness at the cell periphery was assessed by quantitative analysis of fluorescence microscopy images. The stability of the AJ was challenged by calcium deprivation or temperature decrease. Our results showed that plasma membrane hyperpolarization provokes a compaction of AJ-associated actin filaments toward the plasma membrane and an increase in the stability of the AJs. We also observed that the hyperpolarizing procedures determined similar modifications in the actin cytoskeleton of endothelial cells in whole bovine corneas. Together with our previous work, the results of this study contribute to the idea that modifications in the PMP of nonexcitable cells participate in cellular adaptive responses involving reorganization of cytoskeletal components. (c) 2009 Wiley-Liss, Inc.

  11. Safety of cornea and iris in ocular surgery with 355-nm lasers.

    PubMed

    Wang, Jenny; Chung, Jae Lim; Schuele, Georg; Vankov, Alexander; Dalal, Roopa; Wiltberger, Michael; Palanker, Daniel

    2015-09-01

    A recent study showed that 355-nm nanosecond lasers cut cornea with similar precision to infrared femtosecond lasers. However, use of ultraviolet wavelength requires precise assessment of ocular safety to determine the range of possible ophthalmic applications. In this study, the 355-nm nanosecond laser was evaluated for corneal and iris damage in rabbit, porcine, and human donor eyes as determined by minimum visible lesion (MVL) observation, live/dead staining of the endothelium, and apoptosis assay. Single-pulse damage to the iris was evaluated on porcine eyes using live/dead staining. In live rabbits, the cumulative median effective dose (ED50) for corneal damage was 231 J/cm2, as seen by lesion observation. Appearance of endothelial damage in live/dead staining or apoptosis occurred at higher radiant exposure of 287 J/cm2. On enucleated rabbit and porcine corneas, ED50 was 87 and 52 J/cm2, respectively, by MVL, and 241 and 160 J/cm2 for endothelial damage. In human eyes, ED50 for MVL was 110 J/cm2 and endothelial damage at 453 J/cm2. Single-pulse iris damage occurred at ED 50 of 208 mJ/cm2. These values determine the energy permitted for surgical patterns and can guide development of ophthalmic laser systems. Lower damage threshold in corneas of enucleated eyes versus live rabbits is noted for future safety evaluation.

  12. Oligonucleotides targeting TCF4 triplet repeat expansion inhibit RNA foci and mis-splicing in Fuchs' dystrophy.

    PubMed

    Hu, Jiaxin; Rong, Ziye; Gong, Xin; Zhou, Zhengyang; Sharma, Vivek K; Xing, Chao; Watts, Jonathan K; Corey, David R; Mootha, V Vinod

    2018-03-15

    Fuchs' endothelial corneal dystrophy (FECD) is the most common repeat expansion disorder. FECD impacts 4% of U.S. population and is the leading indication for corneal transplantation. Most cases are caused by an expanded intronic CUG tract in the TCF4 gene that forms nuclear foci, sequesters splicing factors and impairs splicing. We investigated the sense and antisense RNA landscape at the FECD gene and find that the sense-expanded repeat transcript is the predominant species in patient corneas. In patient tissue, sense foci number were negatively correlated with age and showed no correlation with sex. Each endothelial cell has ∼2 sense foci and each foci is single RNA molecule. We designed antisense oligonucleotides (ASOs) to target the mutant-repetitive RNA and demonstrated potent inhibition of foci in patient-derived cells. Ex vivo treatment of FECD human corneas effectively inhibits foci and reverses pathological changes in splicing. FECD has the potential to be a model for treating many trinucleotide repeat diseases and targeting the TCF4 expansion with ASOs represents a promising therapeutic strategy to prevent and treat FECD.

  13. Ion transport mechanisms in cultured bovine corneal endothelial cells.

    PubMed

    Jentsch, T J; Keller, S K; Wiederholt, M

    1985-04-01

    Intracellular potential measurements of confluent monolayers of cultured bovine corneal endothelial cells were used to define passive ion transport processes in these cells. Previous studies (Jentsch et al., J. Membr. Biol. 78:103 (1984); Jentsch et al., J. Membr. Biol. 81:189 (1984] have provided the experimental basis for a cellular model, in which bicarbonate entry across the basolateral membrane is indirectly driven by a Na+/H+-exchanger, which is inhibitable by amiloride (1mM). Bicarbonate and sodium should leave the cell via an electrogenic bicarbonate sodium cotransport, which is inhibitable by the disulfonic stilbene derivates SITS or DIDS. This model is also consistent with results from transendothelial studies. In this paper, we briefly review the evidence we have obtained for this model and demonstrate, that the electrical response to sodium (depolarization upon Na+-removal) is neither due to an inhibition of Na+/K+-ATPase nor explainable in terms of changes in K+-conductance. This is concluded from the observation of these responses in the presence of ouabain (10(-4)M) or barium (1mM).

  14. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty

    PubMed Central

    Zafar, Andleeb; Aslanides, Ioannis M.; Selimis, Vasileios; Tsoulnaras, Konstantinos I.; Tabibian, David; Kymionis, George D.

    2018-01-01

    Purpose We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. Methods The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Results Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. Conclusion A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye. PMID:29643797

  15. Express implant in Urrets-Zavalia syndrome after descemet's stripping automated endothelial keratoplasty.

    PubMed

    Muñoz-Morales, A; del Trigo-Zamora, J R; Sánchez-Vicente, J L; Lozano-Bernal, O; Luchena-López, R

    2015-10-01

    The first case is described on a patient with Urrets-Zavalía syndrome after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in whom an ExPRESS implant was used. The ExPRESS implant is a useful tool for complex cases of post-surgical glaucoma where patients need to avoid post-operative inflammation and risks (corneal transplant patients). It is also very useful in cases with a high risk of fibrosis due to previous interventions. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  16. Human SLC4A11-C functions as a DIDS-stimulatable H+(OH−) permeation pathway: partial correction of R109H mutant transport

    PubMed Central

    Kao, Liyo; Azimov, Rustam; Abuladze, Natalia; Newman, Debra

    2014-01-01

    The SLC4A11 gene mutations cause a variety of genetic corneal diseases, including congenital hereditary endothelial dystrophy 2 (CHED2), Harboyan syndrome, some cases of Fuchs' endothelial dystrophy (FECD), and possibly familial keratoconus. Three NH2-terminal variants of the human SLC4A11 gene, named SLC4A11-A, -B, and -C are known. The SLC4A11-B variant has been the focus of previous studies. Both the expression of the SLC4A11-C variant in the cornea and its functional properties have not been characterized, and therefore its potential pathophysiological role in corneal diseases remains to be explored. In the present study, we demonstrate that SLC4A11-C is the predominant SLC4A11 variant expressed in human corneal endothelial mRNA and that the transporter functions as an electrogenic H+(OH−) permeation pathway. Disulfonic stilbenes, including 4,4′-diisothiocyano-2,2′-stilbenedisulfonate (DIDS), 4,4′-diisothiocyanatodihydrostilbene-2,2′-disulfonate (H2DIDS), and 4-acetamido-4′-isothiocyanato-stilbene-2,2′-disulfonate (SITS), which are known to bind covalently, increased SLC4A11-C-mediated H+(OH−) flux by 150–200% without having a significant effect in mock-transfected cells. Noncovalently interacting 4,4′-diaminostilbene-2,2′-disulfonate (DADS) was without effect. We tested the efficacy of DIDS on the functionally impaired R109H mutant (SLC4A11-C numbering) that causes CHED2. DIDS (1 mM) increased H+(OH−) flux through the mutant transporter by ∼40–90%. These studies provide a basis for future testing of more specific chemically modified dilsulfonic stilbenes as potential therapeutic agents to improve the functional impairment of specific SLC4A11 mutant transporters. PMID:25394471

  17. UV-A Irradiation Activates Nrf2-Regulated Antioxidant Defense and Induces p53/Caspase3-Dependent Apoptosis in Corneal Endothelial Cells.

    PubMed

    Liu, Cailing; Vojnovic, Dijana; Kochevar, Irene E; Jurkunas, Ula V

    2016-04-01

    To examine whether Nrf2-regulated antioxidant defense and p53 are activated in human corneal endothelial cells (CEnCs) by environmental levels of ultraviolet A (UV-A), a known stimulator of oxidative stress. Immortalized human CEnCs (HCEnCi) were exposed to UV-A fluences of 2.5, 5, 10, or 25 J/cm2, then allowed to recover for 3 to 24 hours. Control HCEnCi did not receive UV-A. Reactive oxygen species (ROS) were measured using H2DCFDA. Cell cytotoxicity was evaluated by lactate dehydrogenase (LDH) release. Levels of Nrf2, HO-1, NQO-1, p53, and caspase3 were detected by immunnoblotting or real-time PCR. Activated caspase3 was measured by immunoblotting and a fluorescence assay. Exposure of HCEnCi to 5, 10, and 25 J/cm2 UV-A increased ROS levels compared with controls. Nrf2, HO-1, and NQO-1 mRNA increased 1.7- to 3.2-fold at 3 and 6 hours after irradiation with 2.5 and 5 J/cm2 UV-A. At 6 hours post irradiation, UV-A (5 J/cm2) enhanced nuclear Nrf2 translocation. At 24 hours post treatment, UV-A (5, 10, and 25 J/cm2) produced a 1.8- to 2.8-fold increase in phospho-p53 and a 2.6- to 6.0-fold increase in activated caspase3 compared with controls, resulting in 20% to 42% cell death. Lower fluences of UV-A induce Nrf2-regulated antioxidant defense and higher fluences activate p53 and caspase3, indicating that even near-environmental levels of UV-A may affect normal CEnCs. This data suggest that UV-A may especially damage cells deficient in antioxidant defense, and thus may be involved in the etiology of Fuchs' endothelial corneal dystrophy (FECD).

  18. UV-A Irradiation Activates Nrf2-Regulated Antioxidant Defense and Induces p53/Caspase3-Dependent Apoptosis in Corneal Endothelial Cells

    PubMed Central

    Liu, Cailing; Vojnovic, Dijana; Kochevar, Irene E.; Jurkunas, Ula V.

    2016-01-01

    Purpose To examine whether Nrf2-regulated antioxidant defense and p53 are activated in human corneal endothelial cells (CEnCs) by environmental levels of ultraviolet A (UV-A), a known stimulator of oxidative stress. Methods Immortalized human CEnCs (HCEnCi) were exposed to UV-A fluences of 2.5, 5, 10, or 25 J/cm2, then allowed to recover for 3 to 24 hours. Control HCEnCi did not receive UV-A. Reactive oxygen species (ROS) were measured using H2DCFDA. Cell cytotoxicity was evaluated by lactate dehydrogenase (LDH) release. Levels of Nrf2, HO-1, NQO-1, p53, and caspase3 were detected by immunnoblotting or real-time PCR. Activated caspase3 was measured by immunoblotting and a fluorescence assay. Results Exposure of HCEnCi to 5, 10, and 25 J/cm2 UV-A increased ROS levels compared with controls. Nrf2, HO-1, and NQO-1 mRNA increased 1.7- to 3.2-fold at 3 and 6 hours after irradiation with 2.5 and 5 J/cm2 UV-A. At 6 hours post irradiation, UV-A (5 J/cm2) enhanced nuclear Nrf2 translocation. At 24 hours post treatment, UV-A (5, 10, and 25 J/cm2) produced a 1.8- to 2.8-fold increase in phospho-p53 and a 2.6- to 6.0-fold increase in activated caspase3 compared with controls, resulting in 20% to 42% cell death. Conclusions Lower fluences of UV-A induce Nrf2-regulated antioxidant defense and higher fluences activate p53 and caspase3, indicating that even near-environmental levels of UV-A may affect normal CEnCs. This data suggest that UV-A may especially damage cells deficient in antioxidant defense, and thus may be involved in the etiology of Fuchs' endothelial corneal dystrophy (FECD). PMID:27127932

  19. Comparison of central corneal thickness and endothelial cell measurements by Scheimpflug camera system and two noncontact specular microscopes.

    PubMed

    Karaca, Irmak; Yilmaz, Suzan Guven; Palamar, Melis; Ates, Halil

    2017-07-03

    To investigate the correlation of Scheimpflug camera system and two noncontact specular microscopes in terms of central corneal thickness (CCT) and corneal endothelial cell morphology measurements. One hundred eyes of 50 healthy subjects were examined by Pentacam Scheimpflug Analyzer, CEM-530 (Nidek Co, Ltd, Gamagori, Japan) and CellChek XL (Konan Medical, California, USA) via fully automated image analysis with no corrections made. Measurement differences and agreement between instruments were determined by intraclass correlation analysis. The mean age of the subjects was 36.74 ± 8.59 (range 22-57). CCTs were well correlated among all devices, with having CEM-530 the thinnest and CellChek XL the thickest measurements (intraclass correlation coefficient (ICC) = 0.83; p < 0.001 and ICC = 0.78; p < 0.001, respectively). Mean endothelial cell density (ECD) given by CEM-530 was lower than CellChek XL (2613.17 ± 228.62 and 2862.72 ± 170.42 cells/mm 2 , respectively; ICC = 0.43; p < 0.001). Mean value for coefficient of variation (CV) was 28.57 ± 3.61 in CEM-530 and 30.30 ± 3.53 in CellChek XL. Cell hexagonality (HEX) with CEM-530 was higher than with CellChek XL (68.70 ± 4.16% and 45.19 ± 6.58%, respectively). ECDs with CellChek XL and CEM-530 have good correlation, but the values obtained by CellChek XL are higher than CEM-530. Measurements for HEX and CV differ significantly and show weak correlation. Thus, we do not recommend interchangeable use of CellChek XL and CEM-530. In terms of CCTs, Pentacam, CEM-530 and CellChek XL specular microscopy instruments are reliable devices.

  20. Mitomycin-C in corneal surface excimer laser ablation techniques: a report by the American Academy of Ophthalmology.

    PubMed

    Majmudar, Parag A; Schallhorn, Steven C; Cason, John B; Donaldson, Kendall E; Kymionis, George D; Shtein, Roni M; Verity, Steven M; Farjo, Ayad A

    2015-06-01

    To review the published literature assessing the efficacy and safety of mitomycin-C (MMC) as an adjunctive treatment in corneal surface excimer laser ablation procedures. Literature searches of the PubMed and Cochrane Library databases were last conducted on August 19, 2014, without language or date limitations. The searches retrieved a total of 239 references. Of these, members of the Ophthalmic Technology Assessment Committee Refractive Management/Intervention Panel selected 26 articles that were considered to be of high or medium clinical relevance, and the panel methodologist rated each article according to the strength of evidence. Ten studies were rated as level I evidence, 5 studies were rated as level II evidence, and the remaining 11 studies were rated as level III evidence. The majority of the articles surveyed in this report support the role of MMC as an adjunctive treatment in surface ablation procedures. When MMC is applied in the appropriate concentration and confined to the central cornea, the incidence of post-surface ablation haze is decreased. Although a minority of studies that evaluated endothelial cell density (ECD) reported an MMC-related decrease in ECD, no clinical adverse outcomes were reported. Over the past 15 years, the use of MMC during surgery in surface ablation has become widespread. There is good evidence of the effectiveness of MMC when used intraoperatively as prophylaxis against haze in higher myopic ablations. Although there are reports of decreased endothelial counts after the administration of MMC during surgery, the clinical significance of this finding remains uncertain, because no adverse outcomes were reported with as much as 5 years of follow-up. Optimal dosage, effectiveness as prophylaxis in lower myopic and hyperopic ablations, and long-term safety, particularly in eyes with reduced corneal endothelial cell counts from prior intraocular surgery, have yet to be established. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  1. Mutations in LOXHD1, a Recessive-Deafness Locus, Cause Dominant Late-Onset Fuchs Corneal Dystrophy

    PubMed Central

    Riazuddin, S. Amer; Parker, David S.; McGlumphy, Elyse J.; Oh, Edwin C.; Iliff, Benjamin W.; Schmedt, Thore; Jurkunas, Ula; Schleif, Robert; Katsanis, Nicholas; Gottsch, John D.

    2012-01-01

    Fuchs corneal dystrophy (FCD) is a genetic disorder of the corneal endothelium and is the most common cause of corneal transplantation in the United States. Previously, we mapped a late-onset FCD locus, FCD2, on chromosome 18q. Here, we present next-generation sequencing of all coding exons in the FCD2 critical interval in a multigenerational pedigree in which FCD segregates as an autosomal-dominant trait. We identified a missense change in LOXHD1, a gene causing progressive hearing loss in humans, as the sole variant capable of explaining the phenotype in this pedigree. We observed LOXHD1 mRNA in cultured human corneal endothelial cells, whereas antibody staining of both human and mouse corneas showed staining in the corneal epithelium and endothelium. Corneal sections of the original proband were stained for LOXHD1 and demonstrated a distinct increase in antibody punctate staining in the endothelium and Descemet membrane; punctate staining was absent from both normal corneas and FCD corneas negative for causal LOXHD1 mutations. Subsequent interrogation of a cohort of >200 sporadic affected individuals identified another 15 heterozygous missense mutations that were absent from >800 control chromosomes. Furthermore, in silico analyses predicted that these mutations reside on the surface of the protein and are likely to affect the protein's interface and protein-protein interactions. Finally, expression of the familial LOXHD1 mutant allele as well as two sporadic mutations in cells revealed prominent cytoplasmic aggregates reminiscent of the corneal phenotype. All together, our data implicate rare alleles in LOXHD1 in the pathogenesis of FCD and highlight how different mutations in the same locus can potentially produce diverse phenotypes. PMID:22341973

  2. Peroxynitrite Upregulates Angiogenic Factors VEGF-A, BFGF, and HIF-1α in Human Corneal Limbal Epithelial Cells

    PubMed Central

    Ashki, Negin; Chan, Ann M.; Qin, Yu; Wang, Wei; Kiyohara, Meagan; Lin, Lin; Braun, Jonathan; Wadehra, Madhuri; Gordon, Lynn K.

    2014-01-01

    Purpose. Corneal neovascularization (NV) is a sight-threatening condition often associated with infection, inflammation, prolonged contact lens use, corneal burns, and acute corneal graft rejection. Macrophages recruited to the cornea release nitric oxide (NO) and superoxide anion (O2−), which react together to form the highly toxic molecule peroxynitrite (ONOO−). The role of ONOO− in upregulating multiple angiogenic factors in cultured human corneal limbal epithelial (HCLE) cells was investigated. Methods. Human corneal limbal epithelial cells were incubated with 500 μM of ONOO− donor for various times. VEGF-A, BFGF, and hypoxic-inducible factor-alpha (HIF-1α) were investigated via Western blot and RT-PCR was performed for VEGF. Functional assays using human umbilical vein endothelial cells (HUVEC) used conditioned media from ONOO−-exposed HCLE cells. Secreted VEGF from conditioned media was detected and analyzed using ELISA. Results. Increased angiogenic factors were observed as early as 4 hours after HCLE exposure to ONOO−. HIF-1 expression was seen at 4, 6, and 8 hours post-ONOO− exposure (P < 0.05). BFGF expression was elevated at 4 hours and peaked at 8 hours after treatment with ONOO− (P < 0.005). Increased VEGF-A gene expression was observed at 6 and 8 hours post-ONOO− treatment. Functional assays using conditioned media showed increased HUVEC migration and tube formation. Conclusions. Exposure to elevated extracellular concentrations of ONOO− results in upregulation of angiogenic factors in HCLE cells. It is possible that, in the setting of inflammation or infection, that exposure to ONOO− could be one contributor to the complex initiators of corneal NV. Validation in vivo would identify an additional potential control point for corneal NV. PMID:24398102

  3. Peroxynitrite upregulates angiogenic factors VEGF-A, BFGF, and HIF-1α in human corneal limbal epithelial cells.

    PubMed

    Ashki, Negin; Chan, Ann M; Qin, Yu; Wang, Wei; Kiyohara, Meagan; Lin, Lin; Braun, Jonathan; Wadehra, Madhuri; Gordon, Lynn K

    2014-03-19

    Corneal neovascularization (NV) is a sight-threatening condition often associated with infection, inflammation, prolonged contact lens use, corneal burns, and acute corneal graft rejection. Macrophages recruited to the cornea release nitric oxide (NO) and superoxide anion (O2(-)), which react together to form the highly toxic molecule peroxynitrite (ONOO(-)). The role of ONOO(-) in upregulating multiple angiogenic factors in cultured human corneal limbal epithelial (HCLE) cells was investigated. Human corneal limbal epithelial cells were incubated with 500 μM of ONOO(-) donor for various times. VEGF-A, BFGF, and hypoxic-inducible factor-alpha (HIF-1α) were investigated via Western blot and RT-PCR was performed for VEGF. Functional assays using human umbilical vein endothelial cells (HUVEC) used conditioned media from ONOO(-)-exposed HCLE cells. Secreted VEGF from conditioned media was detected and analyzed using ELISA. Increased angiogenic factors were observed as early as 4 hours after HCLE exposure to ONOO(-). HIF-1 expression was seen at 4, 6, and 8 hours post-ONOO(-) exposure (P < 0.05). BFGF expression was elevated at 4 hours and peaked at 8 hours after treatment with ONOO(-) (P < 0.005). Increased VEGF-A gene expression was observed at 6 and 8 hours post-ONOO(-) treatment. Functional assays using conditioned media showed increased HUVEC migration and tube formation. Exposure to elevated extracellular concentrations of ONOO(-) results in upregulation of angiogenic factors in HCLE cells. It is possible that, in the setting of inflammation or infection, that exposure to ONOO(-) could be one contributor to the complex initiators of corneal NV. Validation in vivo would identify an additional potential control point for corneal NV.

  4. Effect of topical epigallocatechin gallate on corneal neovascularization in rabbits.

    PubMed

    Koh, Chang Hyun; Lee, Hyun Soo; Chung, Sung Kun

    2014-05-01

    The aim of this study was to evaluate the efficacy of topical application of epigallocatechin gallate (EGCG) for the treatment of corneal neovascularization in a rabbit model. Corneal neovascularization was induced in 12 rabbits by placing a black silk suture in the corneal stroma (24 eyes) for a week. After suturing, 1 randomly chosen eye of the 12 rabbits was treated with topical EGCG at 2 different concentrations: 0.01% (group 1) and 0.1% (group 2), whereas the contralateral eyes were treated with sterilized balanced salt solution as the control. All eye drops were applied for 2 weeks after suturing. The suture materials were removed from all eyes on day 7. The surface area of corneal neovascularization was measured and analyzed in all eyes on days 7 and 14. On day 14, all eyes were extracted to measure the concentrations of vascular endothelial growth factor (VEGF) messenger RNA and cyclooxygenase-2 (COX-2) protein. The surface area of induced corneal neovascularization was significantly smaller only in group 2 compared with that of the control group on days 7 and 14 (P < 0.001). The change in surface area of corneal neovascularization after removal of the suture material was not significantly different between all 3 groups. VEGF messenger RNA levels were significantly lower in group 2 than in the control group (P < 0.001). The concentration of COX-2 was significantly lower in group 2 than in the control group (P = 0.043), but no significant difference was observed between group 1 and the control group. Topical administration of EGCG effectively inhibits corneal neovascularization in rabbits. This inhibitory effect is probably related to the suppression of VEGF and COX-2 meditated angiogenesis.

  5. Implementation of Organ Culture storage of donor corneas: a 3 year study of its impact on the corneal transplant wait list at the Lions New South Wales Eye Bank.

    PubMed

    Devasahayam, Raj; Georges, Pierre; Hodge, Christopher; Treloggen, Jane; Cooper, Simon; Petsoglou, Con; Sutton, Gerard; Zhu, Meidong

    2016-09-01

    Organ Culture corneal storage offers an extended storage time and increased donor pool and tissue assessment opportunities. In September 2011, the Lions New South Wales Eye Bank (LNSWEB) moved from hypothermic storage to Organ Culture corneal storage. This study evaluates the impact of implementation of Organ Culture on donor eye retrieval and the corneal transplant waiting list over a 3 year period in NSW, Australia. Retrospective review of the LNSWEB data from September 2011 to August 2014. Tissue collection, waiting list and tissue utilization data were recorded. The data from September 2008 to August 2011 for Optisol-GS storage was used for comparison. The annual donor and cornea collection rate increased 35 % and 44 % respectively with Organ Culture compared to Optisol-GS storage. The utilization rate of corneal tissue increased from 73.4 % with hypothermic storage to 77.2 % with Organ Culture storage. The transplant wait list decreased by 77.3 % from September 2011 to August 2014 and correlated with the increased rate of corneal transplantation (r = -0.9381, p < 0.0001). No other factors impacting the wait list changed over this period. Corneas not used from either storage method were due to unacceptable endothelial cell density/viability. The contamination rate of corneas stored in Organ Culture medium was low at 1.74 %. The Organ Culture storage method increases the corneal donor pool available to Eye banks. The practical benefits of the extended storage time and increased donor assessment opportunities have directly led to an increase in corneal utilization rate and a significant decrease in recipient wait list time.

  6. Candida Endophthalmitis After Descemet Stripping Automated Endothelial Keratoplasty With Grafts From Both Eyes of a Donor With Possible Systemic Candidiasis.

    PubMed

    Palioura, Sotiria; Sivaraman, Kavitha; Joag, Madhura; Sise, Adam; Batlle, Juan F; Miller, Darlene; Espana, Edgar M; Amescua, Guillermo; Yoo, Sonia H; Galor, Anat; Karp, Carol L

    2018-04-01

    To report 2 cases with late postoperative Candida albicans interface keratitis and endophthalmitis after Descemet stripping automated endothelial keratoplasty (DSAEK) with corneal grafts originating from a single donor with a history of presumed pulmonary candidiasis. Two patients underwent uncomplicated DSAEK by 2 corneal surgeons at different surgery centers but with tissue from the same donor and were referred to the Bascom Palmer Eye Institute with multifocal infiltrates at the graft-host cornea interface 6 to 8 weeks later, and anterior chamber cultures that were positive for the same genetic strain of C. albicans. Immediate explantation of DSAEK lenticules and daily intracameral and instrastromal voriconazole and amphotericin injections failed to control the infection. Thus, both patients underwent therapeutic penetrating keratoplasty with intraocular lens explantation, pars plana vitrectomy, and serial postoperative intraocular antifungal injection. Both patients are doing well at 2 years postoperatively with best-corrected vision of 20/20 and 20/30+ with rigid gas permeable lenses. One patient required repeat optical penetrating keratoplasty and glaucoma tube implantation 1 year after the original surgery. Literature review reveals that donor lenticule explantation and intraocular antifungals are often inadequate to control fungal interface keratitis, and a therapeutic graft is commonly needed. Interface fungal keratitis and endophthalmitis due to infected donor corneal tissue is difficult to treat, and both recipients of grafts originating from the same donor are at risk of developing this challenging condition.

  7. In vivo laser confocal microscopy findings of a cornea with osteogenesis imperfecta

    PubMed Central

    Kobayashi, Akira; Higashide, Tomomi; Yokogawa, Hideaki; Yamazaki, Natsuko; Masaki, Toshinori; Sugiyama, Kazuhisa

    2014-01-01

    Objective To report the in vivo laser confocal microscopy findings of a cornea with osteogenesis imperfecta (OI) with special attention to the abnormality of Bowman’s layer and sub-Bowman’s fibrous structures (K-structures). Patients and methods Two patients (67-year-old male and his 26-year-old son) with OI type I were included in this study. Slit lamp biomicroscopic and in vivo laser confocal microscopic examinations were performed for both patients. Central corneal thickness and central endothelial cell density were also measured. Results Although the corneas looked clear with normal endothelial density for both eyes in both patients, they were quite thin (386 μm oculus dexter (OD) (the right eye) and 384 μm oculus sinister (OS) (the left eye) in the father and 430 μm OD and 425 μm OS in the son). In both patients, slit lamp biomicroscopic and in vivo laser confocal microscopic examination showed similar results. Anterior corneal mosaics produced by rubbing the eyelid under fluorescein were completely absent in both eyes. In vivo laser confocal microscopy revealed an absent or atrophic Bowman’s layer; a trace of a presumed Bowman’s layer and/or basement membrane was barely visible with high intensity. Additionally, K-structures were completely absent in both eyes. Conclusion The absence of K-structures and fluorescein anterior corneal mosaics strongly suggested an abnormality of Bowman’s layer in these OI patients. PMID:24591812

  8. Fluid temperature at the corneal endothelium during phacoemulsification: comparison of an ophthalmic viscosurgical device and balanced salt solution using the finite element method.

    PubMed

    Reepolmaha, Somporn; Limtrakarn, Wiroj; Uthaisang-Tanechpongtamb, Wanlaya; Dechaumphai, Pramote

    2010-01-01

    The purpose of this study was to estimate and compare the temperatures of two different anterior chamber solutions at the corneal endothelial level during phacoemulsification. An ophthalmic viscosurgical device (OVD) and balanced salt solution (BSS) were compared using the finite element method (FEM). The thermal properties of an OVD (IAL-F) and BSS were studied in an experimental setting. A computer-aided design model of ocular anatomy was created in two dimensions. The phaco needle was considered to be the only source of heat generation. Then, the FEM was used to demonstrate the transient temperature distribution in the two ocular models at 10, 20, 30, 40, 50 and 60 s. In these models, the anterior chamber was filled with IAL-F (IAL-F model) or BSS (BSS model). The heat generation rate of the phaco needle was 0.0004 cal/s/mm(2). The maximum corneal endothelial temperatures for the two models at 60 s were 52.67 and 41.57 degrees C, respectively. The experimental IAL-F model showed fewer changes in temperature for any given time and location. At larger distances from the heat source, less temperature variation was detected. Phacoemulsification is a potential heat-generating procedure performed between the delicate anterior chamber structures. During this procedure, IAL-F protects the endothelium against heat better than BSS. Copyright 2009 S. Karger AG, Basel.

  9. The relationship between corneal biomechanical properties and confocal microscopy findings in normal and keratoconic eyes.

    PubMed

    Hurmeric, Volkan; Sahin, Afsun; Ozge, Gokhan; Bayer, Atilla

    2010-06-01

    To investigate the relationship between corneal biomechanical properties and confocal microscopy (CM) findings in normal and keratoconic eyes. The study consisted of 28 eyes of 28 healthy volunteers and 23 eyes of 15 patients with keratoconus. The diagnosis of keratoconus was made with corneal topography and clinical findings. The corneal hysteresis (CH) and corneal resistance factor (CRF) were measured by the ocular response analyzer. In vivo CM was performed with NIDEK Confoscan 3. CH and CRF were compared with corneal morphological findings (detailed cell counts of endothelial, stromal, and epithelial cells) in vivo. CH was 10.1 +/- 1.3 mm Hg in normal eyes and 7.4 +/- 1.5 mm Hg in keratoconic eyes (P < 0.0001). CRF was 10.1 +/- 1.8 mm Hg in normal eyes and 6.2 +/- 1.4 mm Hg in keratoconic eyes (P < 0.0001). CH and CRF were negatively correlated with full-thickness stromal keratocyte density (P < 0.01; r = -0.52 and P < 0.001; r = -0.67, respectively) in healthy eyes. Keratocyte density of the posterior half of the stroma was found to be significantly related with CRF in healthy eyes (beta = -0.404; P = 0.01). There was no significant relationship among CH, CRF, and CM findings in eyes with keratoconus. There is a significant relationship between CRF and keratocyte density of the posterior half of the stroma in healthy eyes. Our results suggest that corneal elasticity is related to not only stromal matrix but also cellular structure of the cornea.

  10. Stromal fibroblasts are associated with collagen IV in scar tissues of alkali-burned and lacerated corneas.

    PubMed

    Ishizaki, M; Shimoda, M; Wakamatsu, K; Ogro, T; Yamanaka, N; Kao, C W; Kao, W W

    1997-04-01

    Corneal wound healing frequently leads to the formation of opaque scar tissue. We examined whether stromal fibroblastic cells of injured corneas express collagen IV and contributes to the formation of a basal lamina-like structure. Rabbits were anesthetized, and central corneal alkali burn (8 mm in diameter; 1 M NaOH, 1 min) or laceration (8 mm long) were produced. The injured corneas, which had healed for 1, 7, 21 and 45 days, were subjected to histological and immunohistochemical studies with goat anti-collagen IV antibodies, using light and electron microscopy, and in situ hybridization with an antisense digoxigenin-labeled riboprobe of collagen alpha 1(IV) mRNA. For comparison, twenty-day-old fetal corneas were subjected to immunohistochemical study and transmission electron microscopy (TEM). TEM examinations revealed that the stromal collagenous matrix was organized in orthogonal lamellae during corneal development, whereas that of alkali-burned cornea, which had healed for 3 weeks, was disorganized. The stroma of twenty-day-old fetal cornea was not labeled by the anti-collagen IV antibodies. In contrast, one week after injury, specific collagen IV immunostaining was detected in the injured stroma. As the healing proceeded (21-45 days), the antibodies reacted with fibroblastic cells and the extracellular matrix of scar tissues located in the anterior portion of alkali-burned corneas, as well as the posterior portion of lacerated corneas. The middle portion of the stromal tissues was weakly labeled by the anti-collagen IV antibodies with the exception of the blood vessel wall. Immuno-electron microscopic study showed that collagen IV and fibronectin were closely associated with the fibroblastic cells. In situ hybridization demonstrated that epithelial and endothelial cells and fibroblastic cells in the wounded corneal stroma and retro-corneal membrane expressed alpha 1(IV) mRNA, whereas in normal corneas the expression of alpha 1(IV) mRNA was limited to epithelial and endothelial cells. The enhanced expression of collagen IV by the fibroblastic cells in the stroma of injured corneas is consistent with the notion that they may contribute to the formation of basal lamina-like structures in injured corneas.

  11. Ion Transport Function of SLC4A11 in Corneal Endothelium

    PubMed Central

    Jalimarada, Supriya S.; Ogando, Diego G.; Vithana, Eranga N.; Bonanno, Joseph A.

    2013-01-01

    Purpose. Mutations in SLC4A11, a member of the SLC4 superfamily of bicarbonate transporters, give rise to corneal endothelial cell dystrophies. SLC4A11 is a putative Na+ borate and Na+:OH− transporter. Therefore we ask whether SLC4A11 in corneal endothelium transports borate (B[OH]4−), bicarbonate (HCO3−), or hydroxyl (OH−) anions coupled to Na+. Methods. SLC4A11 expression in cultured primary bovine corneal endothelial cells (BCECs) was determined by semiquantitative PCR, SDS-PAGE/Western blotting, and immunofluorescence staining. Ion transport function was examined by measuring intracellular pH (pHi) or Na+ ([Na+]i) in response to Ringer solutions with/without B(OH)4− or HCO3− after overexpressing or small interfering RNA (siRNA) silencing of SLC4A11. Results. SLC4A11 is localized to the basolateral membrane in BCEC. B(OH)4− (2.5–10 mM) in bicarbonate-free Ringer induced a rapid small acidification (0.01 pH unit) followed by alkalinization (0.05–0.1 pH unit), consistent with diffusion of boric acid into the cell followed by B(OH)4−. However, the rate of B(OH)4−-induced pHi change was unaffected by overexpression of SLC4A11. B(OH)4− did not induce significant changes in resting [Na+i] or the amplitude and rate of acidification caused by Na+ removal. siRNA-mediated knockdown of SLC4A11 (∼70%) did not alter pHi responses to CO2/HCO3−-rich Ringer, Na+-free induced acidification, or the rate of Na+ influx in the presence of bicarbonate. However, in the absence of bicarbonate, siSLC4A11 knockdown significantly decreased the rate (43%) and amplitude (48%) of acidification due to Na+ removal and recovery (53%) upon add-back. Additionally, the rate of acid recovery following NH4+ prepulse was decreased significantly (27%) by SLC4A11 silencing. Conclusions. In corneal endothelium, SLC4A11 displays robust Na+-coupled OH− transport, but does not transport B(OH)4− or HCO3−. PMID:23745003

  12. Fuchs' dystrophy associated with radial keratotomy: Lamellar or perforating keratoplasty?

    PubMed

    Rodriguez-Ausin, P; Antolin-Garcia, D; Santamaria Garcia, L; Blazquez-Fernandez, A-B

    2017-05-01

    A 70 year-old male patient with a history of radial keratotomy suffering from Fuchs' dystrophy and a cataract. The patient received a two-step surgery: lens phacoemulsification and intraocular lens implant, followed by descemet stripping automated endothelial keratoplasty in both eyes, four months later. There were no complications apart from a recurrent cystoid macular oedema in both eyes. The best corrected visual acuity was 20/40 both eyes, and the patient was satisfied. Descemet stripping automated endothelial keratoplasty may be considered as an alternative to penetrating keratoplasty in the case of endothelial dysfunction and radial keratotomy in patients with no corneal ectasia or significant stromal opacity. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. [The transfection and expression of IL-1ra gene to the rabbit cornea in situ via cation polymer mediation].

    PubMed

    Yuan, Jin; Chen, Jia-qi; Zhou, Shi-you; Liu, Zu-guo; Wang, Zhi-chong; Gu, Jian-jun

    2006-08-01

    To investigate the efficiency and safety of transfection of PEGFP-IL-1ra plasmid via cation polymer mediation (poly-ethylenimine, PEI) by injection into the corneal stroma. Human IL-1ra cDNA fragments were cloned by RT-PCR. Plasmid PEGFP-hIL-1ra recombinants were constructed and transferred into corneal endothelial cells (CEC) via cation polymer mediation. Expression of IL-1ra mRNA and IL-1ra was detected by green fluorescent protein (GFP) and Western-blotting. In the experiment group, 20 microl preparation containing 10 microg plasmid PEGFP-hIL-1ra recombinants and PEI-in-vivo was injected into the corneal stroma of Wistar rats (n = 30). Equivalent PEI-in-vivo solution was injected into another 15 corneas as the controls. Corneas were harvested at different time points (day 1, 3, 6, 14 and 21) after injection. The changes of tissue structure and function after IL-1ra in situ transfection were studied by HE staining, transmission electron microscopy, trypan blue-alizarin red staining and immunohistochemistry. The location and intensity of IL-1ra-GFP fusion protein expression were monitored by fluorescence microscopy. The size of the RT-PCR product of hIL-1ra fragments was approximately 500 bp in agarose gel electrophoresis. Restrictive enzyme digestion analysis of PstI, BamHI and DNA sequence analysis showed that expression of plasmid PEGFP-hIL-1ra recombinants had been constructed successfully. Twelve hours after the transfection of PEGFP-hIL-1ra, GFP fluorescence was detected in 10% - 15% endothelial cells. IL-1ra protein (RMW: 44,000) was detected by Western-blotting. In PEGFP-hIL-1ra treated group, fluorescence was appeared at day 1 in cornea basal epithelial cells, peaked at day 6 in whole cornea, began to weaken at day 14, and only weak fluorescence remained in cornea epithelial cells at day 21. No fluorescence appeared in the control group. No significant pathologic changes could be found in HE stained cornea tissues in both transfected group and the controls. p63 immunocytochemical staining in cornea epithelium was positive in both groups. Trypan blue-alizarin red staining confirmed that there was no damage in cornea endothelial cells. IL-1ra-GFP granules could be found by transmission electron microscope in every layer of cornea in the transfected group, but none in the controls. There was no impairment in the ultrastructure of cells in both groups. By direct injection of PEGFP-hIL-1ra into corneal stroma and mediated by cation polymer, IL-1ra genes could be transferred and expressed in corneal tissue efficiently and safely, and might provide a novel technique of gene transfection to cornea in situ.

  14. In-vitro corneal transparency measuring system

    NASA Astrophysics Data System (ADS)

    Ventura, Liliane; da Costa Vieira, Marcelo A.; Isaac, Flavio; Chiaradia, Caio; Faria de Sousa, Sidney J.

    2001-06-01

    A system for measuring the average corneal transparency of preserved corneas has been developed in order to provide a more accurate and standard report of the corneal tissue. The donated cornea transparency is one of the features to be analyzed previously to its indication for the transplant. The small portable system consists of two main parts: the optical and the electronic parts. The optical system consists of a white light, lenses and pin-holes that collimate white light beams that illuminates the cornea in its preservative medium. The light that passes through the cornea is detected by a resistive detector and the average corneal transparency is shown in a display. In order to obtain just the tissue transparency, the electronic circuit was built in a way that there is a baseline input of the preservative medium, previous to the measurement of the corneal transparency. Manipulating the system consists of three steps: (1) Adjusting the zero percentage in the absence of light (at this time the detectors in the dark); (2) Placing the preservative medium in the system and adjusting the 100% value (this is the baseline input); (3) Preserving the cornea and placing it in the system. The system provides the tissue transparency. The system is connected to an endothelium evaluation system for Slit Lamp, that we have developed, and statistics about the relationship of the corneal transparency and density of the endothelial cells will be provided in the next years. The system is being used in a public Eye Bank in Brasil.

  15. Daily Wear Contact Lenses Manufactured in Etafilcon A Are Noninferior to Two Silicone Hydrogel Lens Types With Respect to Hypoxic Stress.

    PubMed

    Szczotka-Flynn, Loretta B; Debanne, Sara; Benetz, Beth Ann; Wilson, Tawnya; Brennan, Noel

    2018-05-01

    This study hypothesized that a traditional high-water contact lens of moderate oxygen transmissibility (Dk/t) is noninferior to common silicone hydrogel (SH) lenses worn for daily wear with respect to measures of hypoxic stress. Thirty-six habitual contact lens wearers completed wear of three lens types worn in a randomized order: etafilcon A (ACUVUE 2, control), lotrafilcon B (Air Optix Aqua), and comfilcon A (Biofinity). Central corneal thickness (CT) and limbal hyperemia were measured >2 hr after waking and after 6 to 8 hr of wear on days 1 and 7. Endothelial bleb formation was measured on day 1 of each lens type. Noninferiority of etafilcon A, with respect to the other two lens types, was assumed if the following difference margins of equivalence were met: <1.5% for corneal swelling, <0.5 grade for limbal hyperemia, and <1% area of endothelial blebs. Outcomes were modeled using generalized linear mixed modeling techniques. All lenses showed reductions in least-square mean estimates of CT on both days: etafilcon A -0.26% at day 1 and -0.31% at day 7; lotrafilcon B -1.11% at day 1 and -1.06% at day 7; comfilcon A -0.63% at day 1 and -0.84% at day 7. The difference in mean swelling between etafilcon A and lotrafilcon B was 0.85% at day 1 (95% confidence interval [0.4%-1.3%]) and 0.75% at day 7 (0.3%-1.2%). The difference in mean swelling between etafilcon A and comfilcon A was 0.37% at day 1 (-0.1% to 0.8%) and 0.53% at day 7 (0.1%-1.0%). For limbal redness, etafilcon A fell within 0.1 grade of lotrafilcon B and 0.18 grade of comfilcon A. For endothelial bleb formation, etafilcon A fell within 0.45% of lotrafilcon B and 0.23% of comfilcon A. The etafilcon A control lens resulted in corneal deswelling throughout the day as did the SH lens types. Limbal hyperemia and endothelial bleb formation with all lenses were negligible, and noninferiority assumptions were met between the lens types for all outcomes. Equivalence of etafilcon A with respect to the two SH lenses for three measures of hypoxic stress was demonstrated.

  16. Involvement of NADPH oxidases in alkali burn-induced corneal injury.

    PubMed

    Gu, Xue-Jun; Liu, Xian; Chen, Ying-Ying; Zhao, Yao; Xu, Man; Han, Xiao-Jian; Liu, Qiu-Ping; Yi, Jing-Lin; Li, Jing-Ming

    2016-07-01

    Chemical burns are a major cause of corneal injury. Oxidative stress, inflammatory responses and neovascularization after the chemical burn aggravate corneal damage, and lead to loss of vision. Although NADPH oxidases (Noxs) play a crucial role in the production of reactive oxygen species (ROS), the role of Noxs in chemical burn-induced corneal injury remains to be elucidated. In the present study, the transcription and expression of Noxs in corneas were examined by RT-qPCR, western blot analysis and immunofluorescence staining. It was found that alkali burns markedly upregulated the transcription and expression of Nox2 and Nox4 in human or mouse corneas. The inhibition of Noxs by diphenyleneiodonium (DPI) or apocynin (Apo) effectively attenuated alkali burn-induced ROS production and decreased 3-nitrotyrosine (3-NT) protein levels in the corneas. In addition, Noxs/CD11b double‑immunofluorescence staining indicated that Nox2 and Nox4 were partially co-localized with CD11b. DPI or Apo prevented the infiltration of CD11b-positive inflammatory cells, and inhibited the transcription of inflammatory cytokines following alkali burn-induced corneal injury. In our mouse model of alkali burn-induced corneal injury, corneal neovascularization (CNV) occurred on day 3, and it affected 50% of the whole area of the cornea on day 7, and on day 14, CNV coverage of the cornea reached maximum levels. DPI or Apo effectively attenuated alkali burn‑induced CNV and decreased the mRNA levels of angiogenic factors, including vascular endothelial growth factor (VEGF), VEGF receptors and matrix metalloproteinases (MMPs). Taken together, our data indicate that Noxs play a role in alkali burn-induced corneal injury by regulating oxidative stress, inflammatory responses and CNV, and we thus suggest that Noxs are a potential therapeutic target in the future treatment of chemical-induced corneal injury.

  17. Semi-quantitative assessments of dextran toxicity on corneal endothelium: conceptual design of a predictive algorithm.

    PubMed

    Filev, Filip; Oezcan, Ceprail; Feuerstacke, Jana; Linke, Stephan J; Wulff, Birgit; Hellwinkel, Olaf J C

    2017-03-01

    Dextran is added to corneal culture medium for at least 8 h prior to transplantation to ensure that the cornea is osmotically dehydrated. It is presumed that dextran has a certain toxic effect on corneal endothelium but the degree and the kinetics of this effect have not been quantified so far. We consider that such data regarding the toxicity of dextran on the corneal endothelium could have an impact on scheduling and logistics of corneal preparation in eye banking. In retrospective statistic analyses, we compared the progress of corneal endothelium (endothelium cell loss per day) of 1334 organ-cultured corneal explants in media with and without dextran. Also, the influence of donor-age, sex and cause of death on the observed dextran-mediated effect on endothelial cell counts was studied. Corneas cultured in dextran-free medium showed a mean endothelium cell count decrease of 0.7% per day. Dextran supplementation led to a mean endothelium cell loss of 2.01% per day; this reflects an increase by the factor of 2.9. The toxic impact of dextran was found to be time dependent; while the prevailing part of the effect was observed within the first 24 h after dextran-addition. Donor age, sex and cause of death did not seem to have an influence on the dextran-mediated toxicity. Based on these findings, we could design an algorithm which approximately describes the kinetics of dextran-toxicity. We reproduced the previously reported toxic effect of dextran on the corneal endothelium in vitro. Additionally, this is the first work that provides an algorithmic instrument for the semi-quantitative calculation of the putative endothelium cell count decrease in dextran containing medium for a given incubation time and could thus influence the time management and planning of corneal transplantations.

  18. Association Between Fungal Contamination and Eye Bank-Prepared Endothelial Keratoplasty Tissue: Temperature-Dependent Risk Factors and Antifungal Supplementation of Optisol-Gentamicin and Streptomycin.

    PubMed

    Brothers, Kimberly M; Shanks, Robert M Q; Hurlbert, Susan; Kowalski, Regis P; Tu, Elmer Y

    2017-11-01

    Fungal contamination and infection from donor tissues processed for endothelial keratoplasty is a growing concern, prompting analysis of donor tissues after processing. To determine whether eyebank-processed endothelial keratoplasty tissue is at higher risk of contamination than unprocessed tissue and to model eyebank processing with regard to room temperature exposure on Candida growth in optisol-gentamicin and streptomycin (GS) with and without antifungal supplementation. An examination of the 2013 Eversight Eyebank Study follow-up database for risk factors associated with post-keratoplasty infection identified an increased risk of positive fungal rim culture results in tissue processed for endothelial keratoplasty vs unprocessed tissue. Processing steps at room temperature were hypothesized as a potential risk factor for promotion of fungal growth between these 2 processes. Candida albicans, Candida glabrata, and Candida parapsilosis endophthalmitis isolates were each inoculated into optisol-GS and subjected to 2 different room temperature incubation regimens reflective of current corneal tissue handling protocols. Eversight Eyebank Study outcomes and measures were follow-up inquiries from 6592 corneal transplants. Efficacy study outcomes and measures were fungal colony-forming units from inoculated vials of optisol-GS taken at 2 different processing temperatures. Donor rim culture results were 3 times more likely to be positive for fungi in endothelial keratoplasty-processed eyes (1.14%) than for other uses (0.37%) (difference, 0.77%; 95% CI, 0.17-.1.37) (P = .009). In vitro, increased room temperature incubation of optisol-GS increased growth of Candida species over time. The addition of caspofungin and voriconazole decreased growth of Candida in a species-dependent manner. Detectable Candida growth in donor rim cultures, associated with a higher rate of post keratoplasty infection, is seen in endothelial keratoplasty tissue vs other uses at the time of transplantation, likely owing in part to eyebank preparation processes extending the time of tissue warming. Reduced room temperature incubation and the addition of antifungal agents decreased growth of Candida species in optisol-GS and should be further explored to reduce the risk of infection.

  19. Millimeter wave absorption in the nonhuman primate eye at 35 GHz and 94 GHz.

    PubMed

    Chalfin, Steven; D'Andrea, John A; Comeau, Paul D; Belt, Michael E; Hatcher, Donald J

    2002-07-01

    The purpose of this study was to evaluate anterior segment bioeffects of pulsed 35 GHz and 94 GHz microwave exposure in the nonhuman primate eye. Five juvenile rhesus monkeys (Macaca mulatta) underwent baseline anterior segment ocular assessment consisting of slit lamp examination, corneal topography, specular microscopy, and pachymetry. These studies were repeated after exposure of one eye to pulsed 35 GHz or 94 GHz microwaves at varied fluences, with the other eye serving as a control. The mean fluence required to produce a threshold corneal lesion (faint epithelial edema and fluorescein staining) was 7.5 J cm(-2) at 35 GHz and 5 J cm(-2) at 94 GHz. Transient changes in corneal topography and pachymetry were noted at these fluences. Endothelial cell counts remained unchanged. Threshold corneal injury from 35 GHz and 94 GHz microwave exposure is produced at fluences below those previously reported for CO2 laser radiation. These data may help elucidate the mechanism of thermal injury to the cornea, and resolve discrepancies between IEEE C95.1 (1999), NCRP (1986), and ICNIRP (1998) safety standards for exposure to non-ionizing radiation at millimeter wavelengths.

  20. Secondary angle closure caused by air migrating behind the pupil in descemet stripping endothelial keratoplasty.

    PubMed

    Lee, Jung S; Desai, Neel R; Schmidt, Gregory W; Jun, Albert S; Schein, Oliver D; Stark, Walter J; Eghrari, Allen O; Gottsch, John D

    2009-07-01

    To report secondary angle closure caused by air migrating behind the pupil in the context of intraocular pressure (IOP) elevation in the early postoperative period after Descemet stripping endothelial keratoplasty (DSEK). A retrospective case series was conducted on 100 consecutive DSEK cases from 90 patients undergoing DSEK because of corneal disease from Fuchs corneal dystrophy, pseudophakic bullous keratopathy, aphakic bullous keratopathy, and iridocorneal endothelial syndrome. Preoperative and postoperative slit-lamp examinations and IOP measurements were ascertained for all 100 eyes. Main outcome measures included preoperative and postoperative IOP. Thirteen of 100 eyes developed an IOP rise of greater than 30 mm Hg on the first postoperative day. Six of these 13 patients developed angle closure from air migrating posterior to the iris and causing iridocorneal adhesions. One of these 13 patients developed pupillary block from air anterior to iris. Six of 13 patients developed increased IOP without pupillary block or iridocorneal adhesions and had a history of preexisting primary or secondary glaucoma. A secondary angle closure associated with DSEK is reported with air migrating behind the iris, resulting in extensive iridocorneal adhesions. An acute increase in IOP after DSEK can also be induced by air anterior to the iris causing pupillary block. IOP spikes are much more common in the first few postoperative days after DSEK. Medical treatment can occasionally resolve air posterior to the iris, but if iridocorneal adhesions are extensive and persistent, air removal and angle reformation may be necessary.

  1. Simultaneous versus sequential penetrating keratoplasty and cataract surgery.

    PubMed

    Hayashi, Ken; Hayashi, Hideyuki

    2006-10-01

    To compare the surgical outcomes of simultaneous penetrating keratoplasty and cataract surgery with those of sequential surgery. Thirty-nine eyes of 39 patients scheduled for simultaneous keratoplasty and cataract surgery and 23 eyes of 23 patients scheduled for sequential keratoplasty and secondary phacoemulsification surgery were recruited. Refractive error, regular and irregular corneal astigmatism determined by Fourier analysis, and endothelial cell loss were studied at 1 week and 3, 6, and 12 months after combined surgery in the simultaneous surgery group or after subsequent phacoemulsification surgery in the sequential surgery group. At 3 and more months after surgery, mean refractive error was significantly greater in the simultaneous surgery group than in the sequential surgery group, although no difference was seen at 1 week. The refractive error at 12 months was within 2 D of that targeted in 15 eyes (39%) in the simultaneous surgery group and within 2 D in 16 eyes (70%) in the sequential surgery group; the incidence was significantly greater in the sequential group (P = 0.0344). The regular and irregular astigmatism was not significantly different between the groups at 3 and more months after surgery. No significant difference was also found in the percentage of endothelial cell loss between the groups. Although corneal astigmatism and endothelial cell loss were not different, refractive error from target refraction was greater after simultaneous keratoplasty and cataract surgery than after sequential surgery, indicating a better outcome after sequential surgery than after simultaneous surgery.

  2. [Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber].

    PubMed

    Schmidinger, G; Pemp, B; Werner, L

    2013-11-01

    A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.

  3. Experimental study of viscoelastic in the prevention of corneal endothelial desiccation injury from vitreal fluid-air exchange.

    PubMed

    Cekiç, Osman; Ohji, Masahito; Zheng, Yuping; Hayashi, Atsushi; Kusaka, Shunji; Tano, Yasuo

    2003-05-01

    To evaluate the usefulness of viscoelastic in protecting the corneal endothelium from desiccation injury associated with fluid-air exchange in a rabbit model. Experimental study. Rabbit eyes undergoing pars plana lensectomy and vitrectomy were insufflated with either dry or humidified air for 20 minutes following introduction of either Opegan (sodium hyaluronate 1.0%; Santen, Osaka, Japan) or Viscoat (sodium hyaluronate 3%-chondroitin sulfate 4%; Alcon, Tokyo, Japan) into the anterior chamber. In two other groups of rabbit eyes, the same procedure was performed without using any viscoelastic agent. Corneas obtained from rabbits undergoing surgery were compared with corneas obtained from rabbits not undergoing surgery. Potential alterations in the corneal endothelium were investigated by scanning electron microscopy, by Phalloidin-FITC staining of actin and by in vitro measurements of corneal permeability for carboxyfluorescein using a diffusion chamber. Scanning electron microscopy displayed less distortion of corneal endothelium with Opegan and Viscoat compared with the dry air-only exposed corneas. Using humidified air in Opegan and Viscoat coated corneas maintained the normal actin cytoskeleton during fluid-air exchange. Paracellular leakage was much less with Opegan and Viscoat use following infusion of dry air comparing to that of dry air-only group (P =.026 and P =.041). The difference was much more striking following humidified air infusion in Opegan or Viscoat coated corneas comparing to dry air-only infused corneas (P <.002 and P <.002). Coating of rabbit corneal endothelium with Opegan or Viscoat before fluid-air exchange largely prevents dry air damage to the endothelium. Infusion of humidified air further protects corneal endothelium during fluid-air exchange in aphakic rabbit eyes.

  4. Gamma-Irradiated Sterile Cornea for Use in Corneal Transplants in a Rabbit Model

    PubMed Central

    Yoshida, Junko; Heflin, Thomas; Zambrano, Andrea; Pan, Qing; Meng, Huan; Wang, Jiangxia; Stark, Walter J.; Daoud, Yassine J.

    2015-01-01

    Purpose: Gamma irradiated corneas in which the donor keratocytes and endothelial cells are eliminated are effective as corneal lamellar and glaucoma patch grafts. In addition, gamma irradiation causes collagen cross inking, which stiffens collagen fibrils. This study evaluated gamma irradiated corneas for use in corneal transplantations in a rabbit model comparing graft clarity, corneal neovascularization, and edema. Methods: Penetrating keratoplasty was performed on rabbits using four types of corneal grafts: Fresh cornea with endothelium, gamma irradiated cornea, cryopreserved cornea, and fresh cornea without endothelium. Slit lamp examination was performed at postoperative week (POW) one, two, and four. Corneal clarity, edema, and vascularization were graded. Confocal microscopy and histopathological evaluation were performed. A P < 0.05 was statistically significant. Results: For all postoperative examinations, the corneal clarity and edema were statistically significantly better in eyes that received fresh cornea with endothelium compared to the other three groups (P < 0.05). At POW 1, gamma irradiated cornea scored better than the cryopreserved and fresh cornea without endothelium groups in clarity (0.9 vs. 1.5 and 2.6, respectively), and edema (0.6 vs. 0.8 and 2.0, respectively). The gamma irradiated corneas, cryopreserved corneas and the fresh corneas without endothelium, developed haze and edema after POW 2. Gamma irradiated cornea remained statistically significantly clearer than cryopreserved and fresh cornea without endothelium during the observation period (P < 0.05). Histopathology indicated an absence of keratocytes in gamma irradiated cornea. Conclusion: Gamma irradiated corneas remained clearer and thinner than the cryopreserved cornea and fresh cornea without endothelium. However, this outcome is transient. Gamma irradiated corneas are useful for lamellar and patch grafts, but cannot be used for penetrating keratoplasty. PMID:26180475

  5. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies

    PubMed Central

    Teper, Sławomir J.; Janiszewska, Dominika A.; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward

    2015-01-01

    Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Methods. Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements. PMID:26457303

  6. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies.

    PubMed

    Nowinska, Anna K; Teper, Sławomir J; Janiszewska, Dominika A; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward

    2015-01-01

    To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.

  7. Evaluation of corneal changes after conventional versus accelerated corneal cross-linking: a randomized controlled trial.

    PubMed

    Hashemian, Hesam; Jabbarvand, Mahmoud; Khodaparast, Mehdi; Ameli, Kambiz

    2014-12-01

    To evaluate the outcome of accelerated and conventional corneal cross-linking (CXL) procedures regarding their effect on morphological and optical properties of the cornea. One hundred fifty-three eyes of 153 patients were evaluated before and during a 15-month follow-up period after CXL (76 eyes in the conventional group and 77 eyes in the accelerated group). Measured variables include corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), refraction, maximum keratometry, endothelial cell density, anterior and posterior stromal keratocyte density, and subbasal nerve density. All variables were compared between the two study groups. Cylindrical and spherical components of refraction improved significantly during 15 months of follow-up. No difference was observed between the two study groups. UDVA and CDVA improved in the same manner, with no intergroup differences. Endothelial cell density did not change significantly during the follow-up period in either group. K-max increased slightly in the first month of the follow-up, but started to decrease at postoperative visits without any significant difference in the two groups. Anterior stromal keratocyte density and subbasal nerve density decreased significantly in both groups 1 month postoperatively. Both variables had a more significant decrease in the conventional group at all visits before the 1-year visit. At the final 15-month visit, there were no significant differences in any value between the two groups. Accelerated and conventional CXL seem to have a comparable and acceptable effect on keratoconus in the short-term follow-up period. Copyright 2014, SLACK Incorporated.

  8. Microcoaxial cataract surgery outcomes: comparison of 1.8 mm system and 2.2 mm system.

    PubMed

    Lee, Kyung-Min; Kwon, Hyung-Goo; Joo, Choun-Ki

    2009-05-01

    To compare clinical outcomes of a 1.8 mm and a 2.2 mm microcoaxial cataract surgery system. Department of Ophthalmology and Visual Science, Kangnam St. Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea. In a prospective study, eyes were randomly selected to have phacoemulsification using a Stellaris system or an Intrepid Infiniti system. The initial incision size was 1.8 mm and 2.2 mm, respectively. Measured intraoperative parameters included phacoemulsification time, mean cumulative dissipated ultrasound energy (CDE), change in incision size at each step of surgery, and total volume of balanced salt solution (BSS) used. The best corrected visual acuity (BCVA), corneal astigmatism, corneal thickness, and endothelial cell count were evaluated preoperatively and postoperatively. The study evaluated 86 eyes of 78 patients (43 eyes in each group). There were no significant differences in postoperative BCVA, surgically induced astigmatism, or amount of BSS used between the 2 systems (P >.05). However, for high-density cataracts, the 1.8 mm group had a greater change between the initial incision size and the incision size after phacoemulsification (P = .019, nuclear opalescence [NO] NO3; P = .001, NO4), a longer phacoemulsification time (P = .013, NO3), greater mean CDE (P = .005, NO3; P = .001, NO4), and greater corneal endothelial cell loss (P = .003, NO4). Both systems were safe and effective in microcoaxial phacoemulsification. The 1.8 mm system performed better with cortical-type cataract and the 2.2 mm system, with high-density nuclear-type cataract.

  9. Subclinical Increased Anterior Stromal Reflectivity With Topical Taprenepag Isopropyl

    PubMed Central

    Schachar, Ronald A.; Raber, Susan; Thomas, Kristina V.; Benetz, Beth Ann M.; Szczotka-Flynn, Loretta B.; Zhang, Min; Howell, Scott J.; Lass, Jonathan H.

    2016-01-01

    Purpose To assess the effect of topical taprenepag isopropyl on each layer of the cornea by confocal microscopy. Methods Thirty-two ocular hypertensive or glaucoma patients were randomized into a 2-period, crossover study of 14 days of 0.1% taprenepag alone and in unfixed combination with 0.005% latanoprost (combination therapy). Baseline and sequential slit-lamp biomicroscopy, fluorescein staining, central ultrasonic pachymetry, and confocal microscopy were performed. Confocal images were analyzed for the density of the central superficial and basal epithelium, midstromal keratocytes, and endothelium, as well as endothelial coefficient of variation and percentage of hexagonal cells, and reflectivity of anterior stromal and midstromal layers. Results Corneal staining increased from baseline, reaching a peak at day 13 (69% and 63% of subjects treated with monotherapy and combination therapy, respectively), which resolved by day 35. A statistically significant increase in mean corneal thickness for both eyes and both treatments occurred on days 7 and 13 (range, 20–27 μm; P < 0.001) but recovered (≤6 μm) by day 35. No statistically significant changes were observed in the basal epithelial, midstromal, or endothelial cells. Mean ratio of average reflectivity of anterior stroma to midstroma increased on days 13 and 35 in period 1 for each treatment (range, 1.2–1.9; P < 0.001), and this increase persisted during period 2. Conclusions Anterior stromal reflectivity may remain increased even when biomicroscopic and confocal images of corneal layers remain normal or have recovered after topical taprenepag. This subclinical measure may be useful to detect a persistent adverse effect of a topical agent on the cornea. PMID:22549238

  10. Fuchs' Endothelial Corneal Dystrophy in Patients With Myotonic Dystrophy, Type 1

    PubMed Central

    Winkler, Nelson S.; Milone, Margherita; Martinez-Thompson, Jennifer M.; Raja, Harish; Aleff, Ross A.; Patel, Sanjay V.; Fautsch, Michael P.; Wieben, Eric D.

    2018-01-01

    Purpose RNA toxicity from CTG trinucleotide repeat (TNR) expansion within noncoding DNA of the transcription factor 4 (TCF4) and DM1 protein kinase (DMPK) genes has been described in Fuchs' endothelial corneal dystrophy (FECD) and myotonic dystrophy, type 1 (DM1), respectively. We prospectively evaluated DM1 patients and their families for phenotypic FECD and report the analysis of CTG expansion in the TCF4 gene and DMPK expression in corneal endothelium. Methods FECD grade was evaluated by slit lamp biomicroscopy in 26 participants from 14 families with DM1. CTG TNR length in TCF4 and DMPK was determined by a combination of Gene Scan and Southern blotting of peripheral blood leukocyte DNA. Results FECD grade was 2 or higher in 5 (36%) of 14 probands, significantly greater than the general population (5%) (P < 0.001). FECD segregated with DM1; six of eight members of the largest family had both FECD and DM1, while the other two family members had neither disease. All DNA samples from 24 subjects, including four FECD-affected probands, were bi-allelic for nonexpanded TNR length in TCF4 (<40 repeats). Considering a 75% prevalence of TCF4 TNR expansion in FECD, the probability of four FECD probands lacking TNR expansion was 0.4%. Neither severity of DM1 nor DMPK TNR length predicted the presence of FECD in DM1 patients. Conclusions FECD was common in DM1 families, and the diseases cosegregated. TCF4 TNR expansion was lacking in DM1 families. These findings support a hypothesis that DMPK TNR expansion contributes to clinical FECD.

  11. [Current approaches to evaluating the anatomic and functional status of the cornea].

    PubMed

    Avetisov, S E; Borodina, N V; Kobzova, M V; Musaeva, G M

    2010-01-01

    The review provides data on current methods for evaluating the anatomic and functional status of the cornea (light refraction, light transmission, and biomechanical properties, in particular). It analyzes the main advantages and disadvantages of basic (biomicroscopy, endothelial microscopy, ophthalmometry, topography, and pachymetry) and special (confocal microscopy, optical coherence tomography, ultrasound biomicroscopy, aberrometry, bidirectional corneal applanation, and keratoesthesiometry) studies.

  12. High Peak Power Microwaves: A Health Hazard

    DTIC Science & Technology

    1993-12-01

    activity and/or neural transmission"I4 1. For example, we I have reported electromagnetically induced effects, such as corneal endothelial lesions...increased permeability of the iris vasculature, altered retinal electrophysiologic activity (visual function), and histopathological changesr. The...level"]. The electromagnetic environment can also alter the drug’s action, as has been demonstrated with the anticholinesterase drug, physostigmineM

  13. Novel method to avoid the open-sky condition in penetrating keratoplasty: covered cornea technique.

    PubMed

    Arslan, Osman S; Unal, Mustafa; Arici, Ceyhun; Cicik, Erdoğan; Mangan, Serhat; Atalay, Eray

    2014-09-01

    The aim of this study was to present a novel technique to avoid the open-sky condition in pediatric and adult penetrating keratoplasty (PK). Seventy-two eyes of 65 infants and children and 44 eyes of 44 adult patients were operated on using this technique. After trephining the recipient cornea up to a depth of 50% to 70%, the anterior chamber was entered at 1 point. Then, only a 2 clock hour segment of the recipient button was incised, and this segment was sutured to the recipient rim with a single tight suture. The procedure was repeated until the entire recipient button was excised and resutured. The donor corneal button was sutured to the recipient corneal rim. The sutures between the recipient button and the rim were then cut off, and the recipient button was drawn out. None of the patients operated on with this technique developed complications related to the open-sky condition. Visual acuities, graft failure rates, and endothelial cell loss were comparable with the findings of studies performed for conventional PK. The technique described avoids the open-sky condition during the entire PK procedure. Endothelial cell loss rates are acceptable.

  14. Cx43-hemichannel function and regulation in physiology and pathophysiology: insights from the bovine corneal endothelial cell system and beyond

    PubMed Central

    D'hondt, Catheleyne; Iyyathurai, Jegan; Himpens, Bernard; Leybaert, Luc; Bultynck, Geert

    2014-01-01

    Intercellular communication in primary bovine corneal endothelial cells (BCECs) is mainly driven by the release of extracellular ATP through Cx43 hemichannels. Studying the characteristics of Ca2+-wave propagation in BCECs, an important form of intercellular communication, in response to physiological signaling events has led to the discovery of important insights in the functional properties and regulation of native Cx43 hemichannels. Together with ectopic expression models for Cx43 hemichannels and truncated/mutated Cx43 versions, it became very clear that loop/tail interactions play a key role in controlling the activity of Cx43 hemichannels. Interestingly, the negative regulation of Cx43 hemichannels by enhanced actin/myosin contractility seems to impinge upon loss of these loop/tail interactions essential for opening Cx43 hemichannels. Finally, these molecular insights have spurred the development of novel peptide tools that can selectively inhibit Cx43 hemichannels, but neither Cx43 gap junctions nor hemichannels formed by other Cx isoforms. These tools now set the stage to hunt for novel physiological functions for Cx43 hemichannels in primary cells and tissues and to tackle disease conditions associated with excessive, pathological Cx43-hemichannel openings. PMID:25309448

  15. Natural Killer Cell Cytotoxicity Against SKOV3 after HLA-G Downregulation by shRNA.

    PubMed

    Nazari, Nazanin; Farjadian, Shirin

    2016-09-01

    HLA-G is a nonclassical HLA class I molecule which, when elevated in tumor cells, is one of the main factors involved in tumor evasion of immune responses including NK and T cells. To evaluate the effect of HLA-G downregulation on NK cell cytotoxicity in tumor cell lines. The expression level of HLA-G was measured by real-time PCR and flowcytometry after transfection of SKOV3 by shRNA.1, which targets specific sequences in exon 4, or shRNA.2, which targets both exons 4 and 6. NK-92MI cell cytotoxicity against transfected or untransfected target cell lines was measured with the lactate dehydrogenase (LDH) release assay. The Jeg-3 cell line was used as a positive control. Membrane-bound HLA-G expression levels decreased significantly in both cell lines after transfection with both shRNAs compared to their corresponding untransfected cells (p<0.05). Jeg-3 cells were better lysed than SKOV3 cells by NK cells during the first 48 h after transfection with both shRNAs. Compared to untransfected cells, shRNA.1-transfected SKOV3 cells were significantly more lysed by NK cells 24 h post-transfection (p=0.043). As a clinical approach, HLA-G downregulation with shRNA may be effective in cancer therapy by improving immune cell activation.

  16. Cellular proliferation after experimental glaucoma filtration surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jampel, H.D.; McGuigan, L.J.; Dunkelberger, G.R.

    1988-01-01

    We used light microscopic autoradiography to determine the time course of cellular incorporation of tritiated thymidine (a correlate of cell division) following glaucoma filtration surgery in seven eyes of four cynomolgus monkeys with experimental glaucoma. Incorporation of tritiated thymidine was detected as early as 24 hours postoperatively. Peak incorporation occurred five days postoperatively and had returned to baseline levels by day 11. Cells incorporating tritiated thymidine included keratocytes, episcleral cells, corneal and capillary endothelial cells, and conjunctival and corneal epithelial cells. Transmission electron microscopy was correlated with the autoradiographic results to demonstrate that fibroblasts were dividing on the corneoscleral margin.more » These findings have potential clinical implications for the use of antiproliferative agents after filtration surgery.« less

  17. How normal is the transparent cornea? Effects of aging on corneal morphology.

    PubMed

    Hillenaar, Toine; van Cleynenbreugel, Hugo; Remeijer, Lies

    2012-02-01

    To ascertain the effects of aging on corneal morphology and to illustrate the morphologic diversity of the different layers in the normal cornea as seen by in vivo confocal microscopy (IVCM). Observational cross-sectional study. A total of 150 healthy subjects, evenly distributed over 5 age categories, comprising 75 men and 75 women. Both transparent corneas (n = 300) of all subjects were examined in duplicate by white light IVCM (Confoscan 4, NIDEK Technologies, Albignasego, Padova, Italy). After reviewing the IVCM examinations for morphologic variations of the corneal layers, we selected the 8 most common features to illustrate the morphologic diversity. Subsequently, all 600 IVCM examinations were assessed for the presence of these features. We used binary logistic regression analyses to assess the age-relatedness of each feature. Age distribution of bright superficial epithelial cells, dendriform cells, alterations characteristic of epithelial basement membrane dystrophy (EBMD), tortuous stromal nerves, stromal microdots in the anterior stroma, folds in the posterior stroma, opacification of Descemet's membrane, and corneal guttae. Four features were found characteristic of the aging cornea: stromal microdots in the anterior stroma (P<0.0001), folds in the posterior stroma (P<0.0001), opacification of Descemet's membrane (P<0.0001), and corneal guttae (P<0.0001). Alterations characteristic of EBMD were found in 3% of all eyes and only detected in subjects aged ≥40 years, suggesting age-relatedness (P = 0.09). Other features, such as bright superficial epithelial cells (n = 38, 13%), dendriform cells (n = 42, 14%), and tortuous stromal nerves (n = 115, 38%), were age-independent. We also found a novel phenotype of corneal endothelium in 4 normal eyes of 2 subjects, which we coined "salt and pepper endothelium." We could not establish whether this novel phenotype represented a morphologic variant of normal endothelium, an early stage of a known corneal endothelial disorder, or a completely new disease entity. Knowledge of the common morphologic variations of the corneal layers and the effects of aging on corneal morphology as seen by IVCM increases our understanding of corneal degenerative disorders and is essential to detect corneal pathology. Our finding of a novel phenotype of corneal endothelium emphasizes the morphologic diversity of this optically transparent tissue. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Post DSAEK Optical Changes: A Comprehensive Prospective Analysis on the Role of Ocular Wavefront Aberrations, Haze, and Corneal Thickness

    PubMed Central

    Hindman, Holly B.; Huxlin, Krystel R.; Pantanelli, Seth M.; Callan, Christine L.; Sabesan, Ramkumar; Ching, Steven S.T.; Miller, Brooke E.; Martin, Tim; Yoon, Geunyoung

    2014-01-01

    Purpose To assess the visual impact of ocular wavefront aberrations, corneal thickness, and corneal light scatter prospectively after Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK) in humans. Methods Data were obtained prospectively from 20 eyes pre-operatively and at 1, 3, 6, and 12 months post- DSAEK. At each visit, best spectacle corrected visual acuity (BSCVA) and visual acuity with glare (Brightness Acuity Testing - BAT) were recorded and ocular wavefront measurements and corneal Optical Coherence Tomography (OCT) performed. Magnitude and sign of individual Zernike terms (higher order aberrations HOA) were determined. Epithelial, host stromal, donor stromal, and total corneal thickness were quantified. Brightness, intensity profiles of OCT images were generated to quantify light scatter in the whole cornea, subepithelial region, anterior and posterior host stroma, interface, and donor stroma. Results Mean BSCVA and glare disability at low light levels improved from 1 to 12 months post-DSAEK. All corneal thicknesses and ocular lower- and HOAs were stable from 1 through 12 months, whereas total corneal, host stromal, and interface brightness intensities decreased significantly over the same period. A repeated measures ANOVA across the follow up period found that the change in scatter, but not the change in higher order aberrations, could account for the variability occurring in acuity from 1 to 12 months post-DSAEK. Conclusions While ocular HOAs and scatter are both elevated over normal post-DSAEK, our results demonstrate that improvements in visual performance occurring over the first year post-DSAEK are associated with decreasing light scatter. In contrast, there were no significant changes in ocular HOAs during this time. Because corneal light scatter decreased between 1 and 12 months despite stable corneal thicknesses over the same period, we conclude that factors that induced light scatter, other than tissue thickness or swelling (corneal edema), significantly impacted the visual improvements that occurred over time post-DSAEK. A better understanding of the cellular and extracellular matrix changes of the subepithelial region and interface, incurred by the surgical creation of a lamellar host -graft interface, and the subsequent healing of these tissues, is warranted. PMID:24162748

  19. Donor cornea tissue in cases of drowning or water submersion: eye banks practice patterns and tissue outcomes.

    PubMed

    Vijayakumar, Nithya P; Parikh, Purak; Mian, Shahzad I; Tennant, Brad; Grossman, Gregory H; Albrecht, Bob; Niziol, Leslie M; Woodward, Maria A

    2018-03-01

    Surgical use of donor corneal tissue from victims of water submersion (drowning or submersion secondary to death) remains controversial due to limited evidence about the quality of these tissues. To assess the safety of donor corneal tissue from victims of water submersion, an investigation of eye banks' practice patterns and tissue outcomes was conducted. All 79 Eye Bank Association of America accredited eye banks were contacted for a phone interview of practices regarding tissue from victims of water submersion. A retrospective review of corneal tissues from 2014 to 2016 from a large eye bank network was performed to identify all donors submerged in water. Corneal epithelial integrity, endothelial cell density (ECD), rim cultures, and adverse events were analyzed for associations with water submersion characteristics. 49 eye banks (62% response) participated in the survey. 55% of these eye banks had specific, written protocol for tissue eligibility from donors submerged in water. With or without specific protocol, eye banks reported considering water type (84%) and length of time submerged (92%) to determine eligibility. 22% of eye banks reported medical director involvement when eligibility determination was unclear. 79 tissues from 40 donors who were submerged were identified in 2014-2016 eye bank data. No donor tissues had pre-processing corneal infiltrates, positive rim cultures, or adverse events post-keratoplasty. Corneal epithelial integrity and ECD were not associated with water type or length of time submerged. In conclusion, data from a large eye bank network showed no adverse events or outcomes, indicating these tissues may be safe.

  20. Image-guided modified deep anterior lamellar keratoplasty (DALK) corneal transplant using intraoperative optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Tao, Yuankai K.; LaBarbera, Michael; Ehlers, Justis P.; Srivastava, Sunil K.; Dupps, William J.

    2015-03-01

    Deep anterior lamellar keratoplasty (DALK) is an alternative to full-thickness corneal transplant and has advantages including the absence of allograft rejection; shortened duration of topical corticosteroid treatment and reduced associated risk of glaucoma, cataract, or infection; and enables use of grafts with poor endothelial quality. DALK begins by performing a trephination of approximately 80% stromal thickness, as measured by pachymetry. After removal of the anterior stoma, a needle is inserted into the residual stroma to inject air or viscoelastic to dissect Descemet's membrane. These procedures are inherently difficult and intraoperative rates of Descemet's membrane perforation between 4-39% have been reported. Optical coherence tomography (OCT) provides high-resolution images of tissue microstructures in the cornea, including Descemet's membrane, and allows quantitation of corneal layer thicknesses. Here, we use crosssectional intraoperative OCT (iOCT) measurements of corneal thickness during surgery and a novel micrometeradjustable biopsy punch to precision-cut the stroma down to Descemet's membrane. Our prototype cutting tool allows us to establish a dissection plane at the corneal endothelium interface, mitigates variability in cut-depths as a result of tremor, reduces procedure complexity, and reduces complication rates. iOCT-guided modified DALK procedures were performed on 47 cadaveric porcine eyes by non-experts and achieved a perforation rate of ~5% with a mean corneal dissection time <18 minutes. The procedure was also successful performed on a human donor eye without perforation. Our data shows the potential for iOCT-guided precision anterior segment surgery without variability as a result of tremor and improvements to standard clinical care.

  1. Endothelial cell density to predict endothelial graft failure after penetrating keratoplasty.

    PubMed

    Lass, Jonathan H; Sugar, Alan; Benetz, Beth Ann; Beck, Roy W; Dontchev, Mariya; Gal, Robin L; Kollman, Craig; Gross, Robert; Heck, Ellen; Holland, Edward J; Mannis, Mark J; Raber, Irving; Stark, Walter; Stulting, R Doyle

    2010-01-01

    To determine whether preoperative and/or postoperative central endothelial cell density (ECD) and its rate of decline postoperatively are predictive of graft failure caused by endothelial decompensation following penetrating keratoplasty to treat a moderate-risk condition, principally, Fuchs dystrophy or pseudophakic corneal edema. In a subset of Cornea Donor Study participants, a central reading center determined preoperative and postoperative ECD from available specular images for 17 grafts that failed because of endothelial decompensation and 483 grafts that did not fail. Preoperative ECD was not predictive of graft failure caused by endothelial decompensation (P = .91). However, the 6-month ECD was predictive of subsequent failure (P < .001). Among those that had not failed within the first 6 months, the 5-year cumulative incidence (+/-95% confidence interval) of failure was 13% (+/-12%) for the 33 participants with a 6-month ECD of less than 1700 cells/mm(2) vs 2% (+/-3%) for the 137 participants with a 6-month ECD of 2500 cells/mm(2) or higher. After 5 years' follow-up, 40 of 277 participants (14%) with a clear graft had an ECD below 500 cells/mm(2). Preoperative ECD is unrelated to graft failure from endothelial decompensation, whereas there is a strong correlation of ECD at 6 months with graft failure from endothelial decompensation. A graft can remain clear after 5 years even when the ECD is below 500 cells/mm(2).

  2. Morphometric changes of corneal endothelial cells following intracameral air for micro perforation of the Descemet Membrane during big-bubble deep anterior lamellar keratoplasty.

    PubMed

    Khattak, Ashbala; Nakhli, Fouad R; Abdullatif Abouollo, Hussam Mohammad

    2016-01-01

    The aim of this study was to assess the effect of intracameral air on the endothelial cell morphometrics. This is a retrospective controlled interventional cohort study of 26 patients (18 males and 8 females) who underwent unilateral deep anterior lamellar keratoplasty (DALK) for moderate keratoconus. The DALK patients were divided into two groups: a treatment group (14), which had micro perforations of the Descemet Membrane (DM) intraoperatively and received intracameral air at the end of the surgery; and an independent control group (12), which had no micro perforation and thus no intracameral air was injected. Postoperative best corrected visual acuity (BCVA), sphere, cylinder, spherical equivalent (SEQ), central corneal thickness, and endothelial cell morphometric features consisted of the endothelial cell density (ECD), polymegathism, and pleomorphism were compared between treatment and control groups. The mean BCVA was 0.36 ± 0.36 logMAR in the treatment group and 0.17 ± 0.11 logMAR in the control group (p = 0.081), and the mean corneal thickness was 507.86 ± 62.69 μm in the treatment group and 525.67 ± 37.54 μm in the control group air (p = 0.399). Furthermore, the mean sphere was -5.14 ± 4.17D and -1.02 ± 3.29D, the mean cylinder was -3.16 ± 2.20D and -2.88 ± 1.21D, and the mean SEQ was -6.72 ± 4.66D and -2.46 ± 3.14D and in the treatment and control groups respectively (p = 0.011, 0.693, and 0.013). As to morphometric features, the mean ECD was 2176.76 ± 549.18 cell/mm(2) and 2257.30 ± 436.12 cell/mm(2) in the treatment and control groups respectively (p = 0.686), and the mean pleomorphism 0.48 ± 0.09 and 0.54 ± 0.10 in the treatment and control groups respectively (p = 0.139). In contrast, the mean polymegathism was 0.37 ± 0.06 and 0.31 ± 0.05 in the treatment and control groups respectively (p = 0.009). The presence of air inside the anterior chamber for a short term may not cause further endothelial cell loss and can be safely performed to prevent postoperative Descemet Membrane detachment in case of micro perforations.

  3. Role of Mesenchymal Stem Cells on Cornea Wound Healing Induced by Acute Alkali Burn

    PubMed Central

    Yao, Lin; Li, Zhan-rong; Su, Wen-ru; Li, Yong-ping; Lin, Miao-li; Zhang, Wen-xin; Liu, Yi; Wan, Qian; Liang, Dan

    2012-01-01

    The aim of this study was to investigate the effects of subconjunctivally administered mesenchymal stem cells (MSCs) on corneal wound healing in the acute stage of an alkali burn. A corneal alkali burn model was generated by placing a piece of 3-mm diameter filter paper soaked in NaOH on the right eye of 48 Sprague-Dawley female rats. 24 rats were administered a subconjunctival injection of a suspension of 2×106 MSCs in 0.1 ml phosphate-buffered saline (PBS) on day 0 and day 3 after the corneal alkali burn. The other 24 rats were administered a subconjunctival injection of an equal amount of PBS as a control. Deficiencies of the corneal epithelium and the area of corneal neovascularization (CNV) were evaluated on days 3 and 7 after the corneal alkali burn. Infiltrated CD68+ cells were detected by immunofluorescence staining. The mRNA expression levels of macrophage inflammatory protein-1 alpha (MIP-1α), tumor necrosis factor-alpha (TNF-α), monocyte chemotactic protein-1 (MCP-1) and vascular endothelial growth factor (VEGF) were analyzed using real-time polymerase chain reaction (real-time PCR). In addition, VEGF protein levels were analyzed using an enzyme-linked immunosorbent assay (ELISA). MSCs significantly enhanced the recovery of the corneal epithelium and decreased the CNV area compared with the control group. On day 7, the quantity of infiltrated CD68+ cells was significantly lower in the MSC group and the mRNA levels of MIP-1α, TNF-α, and VEGF and the protein levels of VEGF were also down-regulated. However, the expression of MCP-1 was not different between the two groups. Our results suggest that subconjunctival injection of MSCs significantly accelerates corneal wound healing, attenuates inflammation and reduces CNV in alkaline-burned corneas; these effects were found to be related to a reduction of infiltrated CD68+ cells and the down-regulation of MIP-1α, TNF-α and VEGF. PMID:22363499

  4. Evidence for coupled transport of bicarbonate and sodium in cultured bovine corneal endothelial cells.

    PubMed

    Jentsch, T J; Keller, S K; Koch, M; Wiederholt, M

    1984-01-01

    Using intracellular microelectrode technique, the response of the voltage V across the plasma membrane of cultured bovine corneal endothelial cells to changes in sodium and bicarbonate concentrations was investigated. (1) The electrical response to changes in [HCO3-]o (depolarization upon lowering and hyperpolarization upon raising [HCO3-]o) was dependent on sodium. Lithium could fairly well be substituted for sodium, whereas potassium or choline were much less effective. (2) Removal of external sodium caused a depolarization, while a readdition led to a hyperpolarization, which increased with time of preincubation in the sodium-depleted medium. (3) The response to changes in [Na+]o was dependent on bicarbonate. In a nominally bicarbonate-free medium, its amplitude was decreased or even reversed in sign. (4) Application of SITS or DIDS (10(-3) M) had a similar effect on the response to sodium as bicarbonate-depleted medium. (5) At [Na+]o = 151 mM and [HCO3-]o = 46 mM, the transients of V depended, with 39.0 +/- 9.0 (SD) mV/decade, on bicarbonate and, with 15.3 +/- 5.8 (SD) mV/decade, on sodium. (6) After the preincubation of cells with lithium, replacement of Li by choline led to similar effects as the replacement of sodium by choline, though the response of V was smaller with Li. This response could be reduced or reversed by the removal of bicarbonate or by the application of SITS. (7) Amiloride (10(-3) M) caused a reversible hyperpolarization of the steady-state potential by 8.5 +/- 2.6 mV (SD). It did not affect the immediate response to changes in [Na+]o or [HCO3-]o, but reduced the speed of regaining the steady-state potential after a change in [HCO3-]o. (8) Ouabain (10(-4) M) caused a fast depolarization of -6.8 +/- 1.1 (SD) mV, which was followed by a continuing slower depolarization. The effect was almost identical at 10(-5) M. (9) It is suggested, that corneal endothelial cells possess a cotransport for sodium and bicarbonate, which transports net negative charge with these ions. It is inhibitable by stilbenes, but not directly affected by amiloride or ouabain. Lithium is a good substitute for sodium with respect to bicarbonate transport and is transported itself. In addition, the effect of amiloride provides indirect evidence for the existence of a Na+/H+-antiport. A model for the transepithelial transport of bicarbonate across the corneal endothelium is proposed.

  5. Vulnerability of corneal endothelial cells to mechanical trauma from indentation forces assessed using contact mechanics and fluorescence microscopy.

    PubMed

    Ramirez-Garcia, Manuel A; Khalifa, Yousuf M; Buckley, Mark R

    2018-06-05

    Corneal endothelial cell (CEC) loss occurs from tissue manipulation during anterior segment surgery and corneal transplantation as well as from contact with synthetic materials like intraocular lenses and tube shunts. While several studies have quantified CEC loss for specific surgical steps, the vulnerability of CECs to isolated, controllable and measurable mechanical forces has not been assessed previously. The purpose of this study was to develop an experimental testing platform where the susceptibility of CECs to controlled mechanical trauma could be measured. The corneal endothelial surfaces of freshly dissected porcine corneas were subjected to a range of indentation forces via a spherical stainless steel bead. A cell viability assay in combination with high-resolution fluorescence microscopy was used to visualize and quantify injured/dead CEC densities before and after mechanical loading. In specimens subjected to an indentation force of 9 mN, the mean ± SD peak contact pressure P 0 was 18.64 ± 3.59 kPa (139.81 ± 26.93 mmHg) in the center of indentation and decreased radially outward. Injured/dead CEC densities were significantly greater (p ≤ 0.001) after mechanical indentation of 9 mN (167 ± 97 cells/mm 2 ) compared to before indentation (39 ± 52 cells/mm 2 ) and compared to the sham group (34 ± 31 cells/mm 2 ). In specimens subjected to "contact only" - defined as an applied indentation force of 0.65 mN - the peak contact pressure P 0 was 7.31 ± 1.5 kPa (54.83 ± 11.25 mmHg). In regions where the contact pressures was below 78% of P 0 (<5.7 kPa or 42.75 mmHg), injured/dead CEC densities were within the range of CEC loss observed in the sham group, suggesting negligible cell death. These findings indicate that CECs are highly susceptible to mechanical trauma via indentation, supporting the established "no-touch" policy for ophthalmological procedures. While CECs can potentially remain viable below contact pressures of 5.7 kPa (42.75 mmHg), this low threshold suggests that prevention of indentation-associated CEC loss may be challenging. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Concurrent Acute Retinal Necrosis in a Patient With Iridocorneal Endothelial Syndrome.

    PubMed

    Vignesh, A P; Srinivasan, Renuka

    2016-11-01

    To report a rare case of concurrent acute retinal necrosis in a patient with iridocorneal endothelial syndrome (ICE). Case report. A 42-year-old woman showed acute diminution of vision in the right eye. Her fundus examination revealed features of acute retinal necrosis. She had also experienced gradual diminution of vision in her left eye for 5 years. The examination of her left eye revealed corneal edema with mild corectopia and increased intraocular pressure with abnormal endothelium on specular microscopy pointing to a diagnosis of ICE. This is a rare case where concurrent acute retinal necrosis and ICE syndrome are present in the same patient, possibly pointing to a common viral etiology causing both entities.

  7. Effects of nicotine on corneal wound healing following acute alkali burn.

    PubMed

    Kim, Jong Won; Lim, Chae Woong; Kim, Bumseok

    2017-01-01

    Epidemiological studies have indicated that smoking is a pivotal risk factor for the progression of several chronic diseases. Nicotine, the addictive component of cigarettes, has powerful pathophysiological properties in the body. Although the effects of cigarette smoking on corneal re-epithelialization have been studied, the effects of nicotine on corneal wound healing-related neovascularization and fibrosis have not been fully demonstrated. The aim of this study was to evaluate the effects of chronic administration of nicotine on corneal wound healing following acute insult induced by an alkali burn. BALB/C female mice randomly received either vehicle (2% saccharin) or nicotine (100 or 200 μg/ml in 2% saccharin) in drinking water ad libitum. After 1 week, animals were re-randomized and the experimental group was subjected to a corneal alkali burn, and then nicotine was administered until day 14 after the alkali burn. A corneal alkali burn model was generated by placing a piece of 2 mm-diameter filter paper soaked in 1N NaOH on the right eye. Histopathological analysis and the expression level of the pro-angiogenic genes vascular endothelial growth factor (VEGF) and matrix metalloproteinase-9 (MMP9) revealed that chronic nicotine administration enhanced alkali burn-induced corneal neovascularization. Furthermore, the mRNA expression of the pro-fibrogenic factors α-smooth muscle actin (αSMA), transforming growth factor-β (TGF-β), and collagen α1 (Col1) was enhanced in the high-concentration nicotine-treated group compared with the vehicle group after corneal injury. Immunohistochemical analysis also showed that the αSMA-positive area was increased in chronic nicotine-treated mice after corneal alkali burn. An in vitro assay found that expression of the α3, α7, and β1 nicotinic acetylcholine receptor (nAChR) subunits was significantly increased by chemical injury in human corneal fibroblast cells. Moreover, alkali-induced fibrogenic gene expression and proliferation of fibroblast cells were further increased by treatment with nicotine and cotinine. The proliferation of such cells induced by treatment of nicotine and cotinine was reduced by inhibition of the PI3K and PKC pathways using specific inhibitors. In conclusion, chronic administration of nicotine accelerated the angiogenic and fibrogenic healing processes in alkali-burned corneal tissue.

  8. [EFFECT OF RECOMBINANT ADENOVIRUS-BONE MORPHOGENETIC PROTEIN 12 TRANSFECTION ON DIFFERENTIATION OF PERIPHERAL BLOOD MESENCHYMAL STEM CELLS INTO TENDON/LIGAMENT CELLS].

    PubMed

    Fu, Weili; Chen, Gang; Tang, Xin; Li, Qi; Ll, Jian

    2015-04-01

    To research the effect of recombinant adenovirus-bone morphogenetic protein 12 (Ad-BMP-12) transfection on the differentiation of peripheral blood mesenchymal stem cells (MSCs) into tendon/ligament cells. Peripheral blood MSCs were isolated from New Zealand rabbits (3-4 months old) and cultured in vitro until passage 3. The recombinant adenoviral vector system was prepared using AdEasy system, then transfected into MSCs at passage 3 (transfected group); untransfected MSCs served as control (untransfected group). The morphological characteristics and growth of transfected cells were observed under inverted phase contrast microscope. The transfection efficiency and green fluorescent protein (GFP) expression were detected by flow cytometry (FCM) and fluorescence microscopy. After cultured for 14 days in vitro, the expressions of tendon/ligament-specific markers were determined by immunohistochemistry and real-time fluorescent quantitative PCR. GFP expression could be observed in peripheral blood MSCs at 8 hours after transfection. At 24 hours after transfection, the cells had clear morphology and grew slowly under inverted phase contrast microscope and almost all expressed GFP at the same field under fluorescence microscopy. FCM analysis showed that the transfection efficiency of the transfected group was 99.57%, while it was 2.46% in the untransfected group. The immunohistochemistry showed that the expression of collagen type I gradually increased with culture time in vitro. Real-time fluorescent quantitative PCR results showed that the mRNA expressions of the tendon/ligament-specific genes (Tenomodulin, Tenascin-C, and Decorin) in the transfected group were significantly higher than those in untransfected group (0.061+/- 0.013 vs. 0.004 +/- 0.002, t = -7.700, P=0.031; 0.029 +/- 0.008 vs. 0.003 +/- 0.001, t = -5.741, P=0.020; 0.679 +/- 0.067 vs. 0.142 +/- 0.024, t = -12.998, P=0.000). Ad-BMP-12 can significantly promote differentiation of peripheral blood MSCs into tendon/ligament fibroblasts and enhance the expressions of tendon/ligament-specific phenotypic differentiation, which would provide the evidence for peripheral blood MSCs applied for tendon/ligament regeneration.

  9. Wavelet analysis of corneal endothelial electrical potential difference reveals cyclic operation of the secretory mechanism.

    PubMed

    Cacace, V I; Montalbetti, N; Kusnier, C; Gomez, M P; Fischbarg, J

    2011-09-01

    The corneal endothelium is a fluid-transporting epithelium. As other similar tissues, it displays an electrical potential of ~1 mV (aqueous side negative) across the entire layer [transendothelial potential difference (TEPD)]. It appears that this electrical potential is mainly the result of the transport of anions across the cell layer (from stroma to aqueous). There is substantial evidence that the TEPD is related linearly to fluid transport; hence, under proper conditions, its measure could serve as a measure of fluid transport. Furthermore, the TEPD is not steady; instead, it displays a spectrum of frequency components (0-15 Hz) recognized recently using Fourier transforms. Such frequency components appear due to charge-separating (electrogenic) processes mediated by epithelial plasma membrane proteins (both ionic channels and ionic cotransporters). In particular, the endothelial TEPD oscillations of the highest amplitude (1-2 Hz) were linked to the operation of so-called sodium bicarbonate cotransporters. However, no time localization of that activity could be obtained with the Fourier methodology utilized. For that reason we now characterize the TEPD using wavelet analysis with the aim to localize in time the variations in TEPD. We find that the mentioned high-amplitude oscillatory components of the TEPD appear cyclically during the several hours that an endothelial preparation survives in vitro. They have a period of 4.6 ± 0.4 s on average (n=4). The wavelet power value at the peak of such oscillations is 1.5 ± 0.1 mV(2) Hz on average (n = 4), and is remarkably narrow in its distribution.

  10. Incision integrity and postoperative outcomes after microcoaxial phacoemulsification performed using 2 incision-dependent systems.

    PubMed

    Vasavada, Vaishali; Vasavada, Abhay R; Vasavada, Viraj A; Srivastava, Samaresh; Gajjar, Devarshi U; Mehta, Siddharth

    2013-04-01

    To compare incision integrity and clinical outcomes of 2 microcoaxial phacoemulsification systems. Iladevi Cataract & IOL Research Centre, Ahmedabad, India. Prospective randomized clinical trial. Eyes were randomized to have phacoemulsification using a 1.8 mm clear corneal incision (CCI) system (Group 1, Stellaris system) or a 2.2 mm CCI system (Group 2, Intrepid Infiniti system). Incision enlargement at end of surgery was measured. At the conclusion of surgery, trypan blue was applied over the conjunctival surface, anterior chamber aspirate withdrawn, and ingress into anterior chamber measured. Postoperative observations included evaluation of the CCI using anterior segment optical coherence tomography (AS-OCT), change in central corneal thickness (CCT), and anterior segment inflammation at 1 day, 1 week, and 1 month and endothelial cell loss and surgically induced astigmatism (SIA) at 3 months. Incision enlargement (P<.001) and trypan blue ingress in the anterior chamber (mean 1.7 log units ± 0.6 [SD] versus 3.8 ± 0.6 log units, P<.001) was significantly greater in Group 1 (n = 50) than in Group 2 (n = 50). On AS-OCT, endothelial misalignment and gaping were more frequent in Group 1 at 1 day (P=.001) and 1 week (P=.018). There were no significant differences in SIA, change in CCT, endothelial cell loss, or anterior segment inflammation (P>.05). At the end of surgery, it is not the initial incision size alone but also the distortion of the incision during subsequent stages of surgery that determine the integrity of the CCI. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Ten-year follow-up of photorefractive keratectomy for myopia.

    PubMed

    Koshimizu, Junko; Dhanuka, Raksha; Yamaguchi, Tatsuo

    2010-12-01

    The aim of this study is to evaluate the long-term (10-year) outcome of excimer laser photorefractive keratectomy (PRK) on myopic eyes. This retrospective study included 42 eyes of 29 patients (13 male, 16 female; mean age 33.4 years, range 21 to 60) who were treated with myopic PRK at St. Luke's International Hospital, Tokyo, Japan, from May 1 1995 to December 31 1998, and followed up for more than 10 years. The main outcome measures were efficacy, predictability, stability, safety, and complications. We also evaluated the progress of intraocular pressure, corneal thickness, and endothelial cell density after the surgery. The cases of retreatments were excluded from this study. Ten years after the surgery, 17 eyes (40%) had 20/20 vision or better, and 35 eyes (81%) had 20/40 or better. With regard to the refractive predictability, 55 percent of the eyes were within ± 1.0D and 76% were within ± 2.0D, 10 years after the surgery. There was myopic regression with a mean change in refraction of-0.51 ± 1.78D. Best spectacle-corrected visual acuity (BCVA) was unchanged or improved in 95%, and only two eyes lost 1 line of BCVA. The mean corneal haze score was 0.19 ± 0.40, and the decreasing rate of endothelial cell was 8.30 ± 9.94% at 10 years, which was slightly higher than the spontaneous decreasing rate with age. PRK is safe and effective in refraction even 10 years after surgery; however, further long-term follow-up is needed to evaluate the decreasing of endothelial cells.

  12. Evaluation of an interlaced triple procedure: penetrating keratoplasty, extracapsular cataract extraction, and nonopen-sky intraocular lens implantation.

    PubMed

    Yang, Shuo; Wang, Bin; Zhang, Yangyang; Zhai, Hualei; Wang, Junyi; Wang, Shuang; Xie, Lixin

    2017-09-01

    To evaluate an interlaced triple procedure that involved penetrating keratoplasty (PKP), extracapsular cataract extraction (ECCE) using diathermy capsulotomy, and nonopen-sky intraocular lens (IOL) implantation.This retrospective study involved data from 34 patients who were diagnosed with severe corneal opacities and cataracts. These patients were divided into an interlaced procedure group (21 patients) and a traditional procedure group (13 patients). In the interlaced group, the method of continuous curvilinear capsulorhexis (CCC) was completed via diathermy capsulotomy. The donor corneal button was sutured at 8 positions (at equal intervals) using 10-0 nylon sutures, and the IOL was inserted into the capsular bag using a closed anterior chamber approach at the 10:30 to 12 o'clock positions between the sutures. In the traditional group, CCC was completed using side-port capsular forceps, and the IOL was implanted using an open anterior chamber approach.In the interlaced group, the CCC, open-sky, and total operation times were significantly shorter than in the traditional group (P < .05). Neither the best-corrected visual acuity (BCVA) nor corneal endothelial cell density was significantly different between the groups at 1 and 6 months after the operation.This interlaced triple procedure for the treatment of corneal diseases with cataracts appears to be feasible and practical.

  13. Chitosan and thiolated chitosan: Novel therapeutic approach for preventing corneal haze after chemical injuries.

    PubMed

    Zahir-Jouzdani, Forouhe; Mahbod, Mirgholamreza; Soleimani, Masoud; Vakhshiteh, Faezeh; Arefian, Ehsan; Shahosseini, Saeed; Dinarvand, Rasoul; Atyabi, Fatemeh

    2018-01-01

    Corneal haze, commonly caused by deep physical and chemical injuries, can greatly impair vision. Growth factors facilitate fibroblast proliferation and differentiation, which leads to haze intensity. In this study, the potential effect of chitosan (CS) and thiolated-chitosan (TCS) nanoparticles and solutions on inhibition of fibroblast proliferation, fibroblast to myofibroblast differentiation, neovascularization, extracellular matrix (ECM) deposition, and pro-fibrotic cytokine expression was examined. Transforming growth factor beta-1 (TGFβ 1 ) was induced by interleukin-6 (IL6) in human corneal fibroblasts and expression levels of TGFβ 1 , Platelet-derived growth factor (PDGF), α-smooth muscle actins (α-SMA), collagen type I (Col I), fibronectin (Fn) and vascular endothelial growth factor (VEGF) were quantified using qRT-PCR. To assess wound-healing capacity, TCS-treated mice were examined for α-SMA positive cells, collagen deposition, inflammatory cells and neovascularization through pathological immunohistochemistry. The results revealed that CS and TCS could down-regulate the expression levels of TGFβ 1 and PDGF comparable to that of TGFβ 1 knockdown experiment. However, down-regulation of TGFβ 1 was not regulated through miR29b induction. Neovascularization along with α-SMA and ECM deposition were significantly diminished. According to these findings, CS and TCS can be considered as potential anti-fibrotic and anti-angiogenic therapeutics. Furthermore, TCS, thiolated derivative of CS, will increase mucoadhesion of the polymer at the corneal surface which makes the polymer efficient and non-toxic therapeutic approach for corneal injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. A Comparison of Endothelial Cell Loss in Combined Cataract and MIGS (Hydrus) Procedure to Phacoemulsification Alone: 6-Month Results

    PubMed Central

    Fea, Antonio M.; Consolandi, Giulia; Pignata, Giulia; Cannizzo, Paola Maria Loredana; Lavia, Carlo; Billia, Filippo; Rolle, Teresa; Grignolo, Federico M.

    2015-01-01

    Purpose. To compare the corneal endothelial cell loss after phacoemulsification, alone or combined with microinvasive glaucoma surgery (MIGS), in nonglaucomatous versus primary open angle glaucoma (POAG) eyes affected by age-related cataract. Methods. 62 eyes of 62 patients were divided into group 1 (n = 25, affected by age-related cataract) and group 2 (n = 37, affected by age-related cataract and POAG). All patients underwent cataract surgery. Group 2 was divided into subgroups A (n = 19, cataract surgery alone) and B (n = 18, cataract surgery and MIGS). Prior to and 6 months after surgery the patients' endothelium was studied. Main outcomes were CD (cell density), SD (standard deviation), CV (coefficient of variation), and 6A (hexagonality coefficient) variations after surgeries. Results. There were no significant differences among the groups concerning preoperative endothelial parameters. The differences in CD before and after surgery were significant in all groups: 9.1% in group 1, 17.24% in group 2A, and 11.71% in group 2B. All endothelial parameters did not significantly change after surgery. Conclusions. Phacoemulsification determined a loss of endothelial cells in all groups. After surgery the change in endothelial parameters after MIGS was comparable to the ones of patients who underwent cataract surgery alone. PMID:26664740

  15. Comparison of graft survival following penetrating keratoplasty and Descemet's stripping endothelial keratoplasty in eyes with a glaucoma drainage device.

    PubMed

    Iverson, Shawn M; Spierer, Oriel; Papachristou, George C; Feuer, William J; Shi, Wei; Greenfield, David S; O'Brien, Terrence P

    2018-02-01

    To compare corneal graft survival rates after penetrating keratoplasty (PK) and Descemet's stripping endothelial keratoplasty (DSEK) in patients with a glaucoma drainage device (GDD) or medically managed glaucoma. A retrospective chart review was conducted on consecutive patients who underwent primary PK or primary DSEK. Inclusion criteria consisted of eyes with a diagnosis of glaucoma prior to corneal transplantation and a minimum of 6 months of follow-up. Graft failure was defined as an edematous cornea with failure to maintain deturgescence lasting beyond a period of 1 month of intense steroid therapy or vascularization and scarring resulting in irreversible loss of central graft clarity. Corneal graft survival was calculated using Kaplan-Meier survival analysis. Patients were divided into four groups: GDD-PK, GDD-DSEK, medical-PK and medical-DSEK. Fifty-six eyes of 56 patients were identified as meeting inclusion criteria. Among eyes with a GDD, there was no difference in the proportion of failures between PK grafts (48%) and DSEK grafts (50%) (p = 0.90). Failure occurred earlier in DSEK recipients compared to PK recipients, 5.82 ± 6.77 months versus 14.40 ± 7.70 months, respectively (p = 0.04). A Kaplan-Meier analysis did not identify a difference between the four groups with respect to graft failure (p = 0.52). There is no significant difference in graft survival rates between medically and surgically treated glaucoma patients for either PK or DSEK grafts. In patients with GDD, graft failure occurs earlier in DSEK compared to PK.

  16. Pore size assessment during corneal endothelial cells permeabilization by femtosecond laser activated carbon nanoparticles

    NASA Astrophysics Data System (ADS)

    Jumelle, C.; Mauclair, C.; Houzet, J.; Bernard, A.; He, Z.; Piselli, S.; Perrache, C.; Egaud, G.; Baubeau, E.; Gain, P.; Thuret, G.

    2015-07-01

    Corneal therapeutic molecules delivery represents a promising solution to maintain human corneal endothelial cells (HCECs) viability, but the difficulty is transport across cell membrane. A new delivery method published recently consists in ephemerally permeabilizing cell membranes using a photo-acoustic reaction produced by carbon nanoparticles (CNPs) and femtosecond laser (FsL). The aim of this work is to investigate the size of pores formed at cell membrane by this technique. To induce cell permeabilization, HCECs were put in contact with CNPs and irradiated with a 500 μm diameter Ti:Sa FsL focalized spot. Four sizes of marker molecules were delivered into HCECs to investigate pore sizes: calcein (1.2 nm), FITC-Dextran 4kDa (2.8 nm) and FITC-Dextran 70kDa (12 nm) and FITC-Dextran 2MDa (50 nm). Delivery of each molecule was assessed by flow cytometry, a technique able to measure their presence into cells. We showed that the delivery rate was dependent of their size. Calcein was delivered in 56.1±8.2% of HCECs, FITC-Dextran 4kDa in 42.2±3.5%, FITC-Dextran 70 kDa in 21.5±2.7% and finally FITC-Dextran 2MDa in 12.9±2.0%. It means that a large number of pores in the size ranging from 1.2 to 2.8 nm were formed. However, 12 nm and larger pores were almost half more infrequent. Pore sizes formed at cell membrane by the technique of cell permeabilization by FsL activated CNPs was investigated. The results indicated that the pore sizes are large enough for the efficient delivery of small, medium and big therapeutics molecules on HCECs by this technique.

  17. Accelerated corneal crosslinking concurrent with laser in situ keratomileusis.

    PubMed

    Celik, H Ugur; Alagöz, Nese; Yildirim, Yusuf; Agca, Alper; Marshall, John; Demirok, Ahmet; Yilmaz, Omer Faruk

    2012-08-01

    To assess accelerated corneal collagen crosslinking (CXL) applied concurrently with laser in situ keratomileusis (LASIK) in a small group of patients. Beyoglu Eye Research and Training Hospital, Istanbul, Turkey. Prospective pilot interventional case series. In May 2010, patients had LASIK with concurrent accelerated CXL in 1 eye and LASIK only in the fellow eye to treat myopia or myopic astigmatism. The follow-up was 12 months. The attempted correction (spherical equivalent) ranged from -5.00 to -8.50 diopters (D) in the LASIK-CXL group and from -3.00 to -7.25 D in the LASIK-only group. Main outcome measures were manifest refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and the endothelial cell count. Eight eyes of 3 women and 1 man (age 22 to 39 years old) were enrolled. At the 12-month follow-up, the LASIK-CXL group had a UDVA and manifest refraction equal to or better than those in the LASIK-only group. No eye lost 1 or more lines of CDVA at the final visit. The endothelial cell loss in the LASIK-CXL eye was not greater than in the fellow eye. No side effects were associated with either procedure. Laser in situ keratomileusis with accelerated CXL appears to be a promising modality for future applications to prevent corneal ectasia after LASIK treatment. The results in this pilot series suggest that evaluation of a larger study cohort is warranted. Drs. Yilmaz and Marshall are paid consultants to Avedro, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Customized humanoptics silicone iris prosthesis in eyes with posttraumatic iris loss: outcomes and complications.

    PubMed

    Spitzer, Martin Stephan; Nessmann, Anja; Wagner, Julia; Yoeruek, Efdal; Bartz-Schmidt, Karl Ulrich; Szurman, Peter; Szurman, Gesine B

    2016-05-01

    Posttraumatic partial or total iris defects often cause significant debilitating glare, photophobia, decreased vision and cosmetic problems. Currently, the best cosmetic results can be obtained with a customized silicone iris prosthesis. However, little is known about the functional results and the rate of complication if this type of iris prosthesis is implanted into severely traumatized eyes. The aim of this study is to analyse the functional and cosmetic outcomes as well as complications after Artificial Iris implantation. A consecutive series of 34 patients who received a customized silicone iris prosthesis after severe globe injury with total or sub-total iris loss was analysed retrospectively. Additionally, patients were interviewed regarding change in subjective complaints. Median follow-up was 24 months (range 12.0-48.8). Mean visual acuity prior to Artificial Iris implantation was 1.1 logMAR (range 0.3-2.6). Five patients (15%) had pre-existing glaucoma and eight patients (24%) had pre-existing hypotony. Visual acuity 12 months after surgery was 1.4 logMAR (range 0.2-2.6). Complications included newly diagnosed glaucoma in three eyes (9%) and hypotony in three eyes (9%), persisting intraocular inflammation or macular oedema in seven patients (21%), and corneal endothelial decompensation requiring corneal transplantation in six patients (18%). Patients' satisfaction increased by reducing glare and enhanced cosmetic appearance. The customized silicone iris prosthesis is an individualized treatment approach with appealing cosmetic results. Therefore, especially traumatized eyes with highly different posttraumatic conditions could benefit. However, in some patients, the implantation of this device may cause an increase of intraocular pressure, corneal endothelial decompensation or persisting inflammation. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. Hypothermic preservation of corneas in a hyperkalaemic solution (CPTES): II. Extended storage in the presence of chondroitin sulphate.

    PubMed Central

    Taylor, M J; Hunt, C J; Madden, P W

    1989-01-01

    Periods of preservation for donor corneas, even for short times, are necessary to facilitate optimum conditions in penetrating keratoplasty. However, current techniques for corneal storage at low temperatures may not provide optimal conditions for maintaining tissue integrity. In particular, the ionic composition of the storage medium has received little attention since it has been assumed throughout that the normal complement of ions in tissue culture media will also be suitable for preservation at reduced temperatures. This study extends our previous investigations on the merits of using CPTES (corneal-potassium-TES), a potassium-rich balanced salt solution containing an impermeant anionic pH buffer (TES), as a storage solution specifically designed to prevent the loss of intracellular potassium and minimise endothelial cell swelling during the time that the normal regulatory processes are switched off. The effect of adding the natural polymer chondroitin sulphate (CS) as a colloid osmotic agent to the hyperkalaemic storage medium is now examined. Corneas stored in CPTES containing 2.5% chondroitin sulphate retained a very high level of structural and functional integrity after three, five, and seven days storage at 0 degrees C; furthermore, stromal swelling was restricted to only 21%. All corneas stored in CPTES + 2.5% CS showed active endothelial function by thinning efficiently at rates that were greater than those previously reported for rabbit corneas stored for similar lengths of time in either M-K medium or K-sol. The zwitterionic buffers TES and HEPES were interchangeable in the hyperkalaemic solution and were non-toxic to corneal endothelium at a concentration of 100 mM. These compounds offer excellent pH buffering in bicarbonate-free medium. Images PMID:2510816

  20. Inhibition of rat corneal angiogenesis by a nuclease-resistant RNA aptamer specific for angiopoietin-2

    PubMed Central

    White, Rebekah R.; Shan, Siqing; Rusconi, Christopher P.; Shetty, Geetha; Dewhirst, Mark W.; Kontos, Christopher D.; Sullenger, Bruce A.

    2003-01-01

    Angiopoietin-2 (Ang2) appears to be a naturally occurring antagonist of the endothelial receptor tyrosine kinase Tie2, an important regulator of vascular stability. Destabilization of the endothelium by Ang2 is believed to potentiate the actions of proangiogenic growth factors. To investigate the specific role of Ang2 in the adult vasculature, we generated a nuclease-resistant RNA aptamer that binds and inhibits Ang2 but not the related Tie2 agonist, angiopoietin-1. Local delivery of this aptamer but not a partially scrambled mutant aptamer inhibited basic fibroblast growth factor-mediated neovascularization in the rat corneal micropocket angiogenesis assay. These in vivo data directly demonstrate that a specific inhibitor of Ang2 can act as an antiangiogenic agent. PMID:12692304

  1. Donor and tissue profile of a community eye bank in Eastern India.

    PubMed

    Ranjan, Abhishek; Das, Sujata; Sahu, Srikant K

    2014-09-01

    The purpose of this study is to analyze the donor and tissue profile of a community eye bank in Eastern India. Eye bank records were analyzed for the period July 2007-June 2011. Variables analyzed included donor demographics (age, gender, and ethnicity), donor cause of death, consent for recovery, death-to-preservation interval, preservation-to-utilization interval, endothelial cell density (ECD), corneal suitability for transplantation, and corneal tissue utilization. During this study period, 743 corneal tissues were retrieved from 373 donors (male:female = 263:110). The mean age of donors was 52 ± 21 years (range: 3-95 years). The most common donor age group was 41-50 and 71-80 years. Most of the donors belonged to one religious faith (99%). The most common causes of death were cardiorespiratory failure (34%) followed by road traffic accident (30%). Majority donors were motivated (n = 320; 86%), and remaining (n = 53; 14%) were voluntary. Most of the consents were given by sons or daughters of the deceased (45%) followed by siblings (18%). Mean death-to-preservation interval was 3.9 ± 1.9 h. Mean preservation-to-utilization interval was 56.0 ± 24.4 h. The mean ECD of donor corneal tissue was 2857 ± 551 cells/mm 2 and the median value was 2898 cells/mm 2 . Of harvested corneas 556 (75%) corneal tissues were utilized. The most common causes of nonutilization were septicemia in donor (n = 56; 30%) and poor quality of tissue (n = 55; 30%). Although, there is significant corneal tissue utilization, there is a need for increased awareness among people in order to augment voluntary donations.

  2. Corneal Thickness as a Predictor of Corneal Transplant Outcome

    PubMed Central

    Verdier, David D.; Sugar, Alan; Baratz, Keith; Beck, Roy; Dontchev, Mariya; Dunn, Steven; Gal, Robin L.; Holland, Edward J.; Kollman, Craig; Lass, Jonathan H.; Mannis, Mark J.; Penta, Jeffrey

    2013-01-01

    Purpose Assess corneal thickness (CT) and correlation with graft outcome after penetrating keratoplasty in the Cornea Donor Study. Methods 887 subjects with a corneal transplant for a moderate risk condition (principally Fuchs or pseudophakic corneal edema) had post-operative CT measurements throughout a 5 year follow up time. Relationships between baseline (recipient, donor, and operative) factors and CT were explored. Proportional hazards models were used to assess association between CT and graft failure. Relationship between CT and cell density was assessed with a longitudinal repeated measures model and Spearman correlation estimates. Results Higher longitudinal CT measurements were associated with diagnosis of pseudophakic or aphakic corneal edema (P<0.001), intraocular pressure > 25mmHg during the first post-operative month (P=0.003), white (non-Hispanic) donor race (P=0.002) and respiratory causes of donor death (P<0.001). Among those without graft failure within the first post-operative year, the 5-year cumulative incidence (±95% CI) of graft failure was 5% ± 5% in those with a 1-year CT ≤500μm, 5% ± 3% for CT 501 – 550μm, 7% ± 4% for CT 551 – 600μm and 20% ± 11% for CT >600μm. In multivariate analysis, both 1 year CT and cell density were associated with subsequent graft failure (P=0.002 and 0.009). CT increase was modestly associated with endothelial cell loss during follow up (r=-0.29). Conclusion During the first 5 years following penetrating keratoplasty, CT can serve as a predictor of graft survival. However, CT is not a substitute for cell density measurement as both measures were independently predictive of graft failure. PMID:23343949

  3. Effect of chemical composition on corneal tissue response to photopolymerized materials comprising 2-hydroxyethyl methacrylate and acrylic acid.

    PubMed

    Lai, Jui-Yang

    2014-01-01

    The purpose of this work was to investigate the relationship between the feed composition of 2-hydroxyethyl methacrylate (HEMA)/acrylic acid (AAc) and hydrogel material compatibility towards ocular anterior segment tissues, particularly the corneal endothelium. The monomer solutions of HEMA and AAc were mixed at varying volume ratios of 92:0, 87:5, 82:10, 77:15, and 72:20, and were subjected to UV irradiation. Then, the 7-mm-diameter membrane implants made from photopolymerized materials were placed into the ocular anterior chamber for 4days and assessed by biomicroscopic examinations, corneal thickness measurements, and quantitative real-time reverse transcription polymerase chain reaction analyses. The poly(HEMA-co-AAc) implants prepared from the solution mixture containing 0-10vol.% AAc displayed good biocompatibility. However, with increasing volume ratio of AAc and HEMA from 15:77 to 20:72, the enhanced inflammatory response, decreased endothelial cell density, and increased ocular score and corneal thickness were observed, probably due to the influence of surface charge of copolymer membranes. On the other hand, the ionic pump function of corneal endothelium exposed to photopolymerized membranes was examined by analyzing the Na(+),K(+)-ATPase alpha 1 subunit (ATP1A1) expression level. The presence of the implants having higher amount of AAc incorporated in the copolymers (i.e., 15.1 to 24.7μmol) and zeta potential (i.e., -38.6 to -56.5mV) may lead to abnormal transmembrane transport. It is concluded that the chemical composition of HEMA/AAc has an important influence on the corneal tissue responses to polymeric biomaterials. © 2013.

  4. The clinical outcomes of surgical management of anterior chamber migration of a dexamethasone implant (Ozurdex®).

    PubMed

    Kang, Hyunseung; Lee, Min Woo; Byeon, Suk Ho; Koh, Hyoung Jun; Lee, Sung Chul; Kim, Min

    2017-09-01

    Our purpose was to describe the clinical course, and individualized management approaches, of patients with migration of a dexamethasone implant into the anterior chamber. This was a retrospective review of four patients with seven episodes of anterior chamber migration of a dexamethasone implant. After 924 intravitreal dexamethasone injections, anterior migration of the implant occurred in four eyes of four patients (0.43%). All four eyes were pseudophakic: one eye had a posterior chamber intraocular lens in the capsular bag but in a post-laser posterior capsulotomy state, two eyes had a sulcus intraocular lens (IOL), and one eye had an iris-fixated retropupillary IOL. All eyes had a prior vitrectomy and no lens capsule. The time interval from injection to detection of the implant migration ranged from 2 to 6 weeks. Of the four eyes with corneal edema, only one eye required a corneal transplantation, although it was unclear whether the implant migration was the direct cause of the corneal decompensation because the patient had a history of bullous keratopathy resulting from an extended history of uveitis. All patients underwent surgical intervention: two patients with a repositioning procedure, and the other two patients with removal due to repeated episodes, although surgical removal was not always necessary to reverse the corneal complications. In our study, not all patients required surgical removal of the implants. Repositioning the implant back into the vitreous cavity may be considered as an option in cases involving the first episode with no significant corneal endothelial decompensation. Considering potential anterior segment complications and the loss of drug effectiveness together, an individualized approach is recommended to obtain the best treatment outcomes and to minimize the risk of corneal complications.

  5. The effect of standard and high-fluence corneal cross-linking (CXL) on cornea and limbus.

    PubMed

    Richoz, Olivier; Tabibian, David; Hammer, Arthur; Majo, François; Nicolas, Michael; Hafezi, Farhad

    2014-07-22

    When treating peripheral ectatic disease-like pellucid marginal degeneration (PMD), corneal cross-linking with UV-A and riboflavin (CXL) must be applied eccentrically to the periphery of the lower cornea, partly irradiating the corneal limbus. Here, we investigated the effect of standard and double-standard fluence corneal cross-linking with riboflavin and UV-A (CXL) on cornea and corneal limbus in the rabbit eye in vivo. Epithelium-off CXL was performed in male New Zealand White rabbits with two irradiation diameters (7 mm central cornea, 13 mm cornea and limbus), using standard fluence (5.4 J/cm(2)) and double-standard fluence (10.8 J/cm(2)) settings. Controls were subjected to epithelial removal and riboflavin instillation, but were not irradiated with UV-A. Following CXL, animals were examined daily until complete closure of the epithelium, and at 7, 14, 21, and 28 days. Animals were killed and a corneoscleral button was excised and processed for light microscopy and immunohistochemistry. For both irradiation diameters and fluences tested, no signs of endothelial damage or limbal vessel thrombosis were observed, and time to re-epithelialization was similar to untreated controls. Histological and immunohistochemical analysis revealed no differences in the p63 putative stem cell marker expression pattern. Even when using fluence twice as high as the one used in current clinical CXL settings, circumferential UV-A irradiation of the corneal limbus does not alter the regenerative capacity of the limbal epithelial cells, and the expression pattern of the putative stem cell marker p63 remains unchanged. This suggests that eccentric CXL may be performed safely in PMD. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  6. Customized Corneal Cross-Linking-A Mathematical Model.

    PubMed

    Caruso, Ciro; Epstein, Robert L; Ostacolo, Carmine; Pacente, Luigi; Troisi, Salvatore; Barbaro, Gaetano

    2017-05-01

    To improve the safety, reproducibility, and depth of effect of corneal cross-linking with the ultraviolet A (UV-A) exposure time and fluence customized according to the corneal thickness. Twelve human corneas were used for the experimental protocol. They were soaked using a transepithelial (EPI-ON) technique using riboflavin with the permeation enhancer vitamin E-tocopheryl polyethylene glycol succinate. The corneas were then placed on microscope slides and irradiated at 3 mW/cm for 30 minutes. The UV-A output parameters were measured to build a new equation describing the time-dependent loss of endothelial protection induced by riboflavin during cross-linking, as well as a pachymetry-dependent and exposure time-dependent prescription for input UV-A fluence. The proposed equation was used to establish graphs prescribing the maximum UV-A fluence input versus exposure time that always maintains corneal endothelium exposure below toxicity limits. Analysis modifying the Lambert-Beer law for riboflavin oxidation leads to graphs of the maximum safe level of UV-A radiation fluence versus the time applied and thickness of the treated cornea. These graphs prescribe UV-A fluence levels below 1.8 mW/cm for corneas of thickness 540 μm down to 1.2 mW/cm for corneas of thickness 350 μm. Irradiation times are typically below 15 minutes. The experimental and mathematical analyses establish the basis for graphs that prescribe maximum safe fluence and UV-A exposure time for corneas of different thicknesses. Because this clinically tested protocol specifies a corneal surface clear of shielding riboflavin on the corneal surface during UV-A irradiation, it allows for shorter UV-A irradiation time and lower fluence than in the Dresden protocol.

  7. A new nanosecond UV laser at 355 nm: early results of corneal flap cutting in a rabbit model.

    PubMed

    Trost, Andrea; Schrödl, Falk; Strohmaier, Clemens; Bogner, Barbara; Runge, Christian; Kaser-Eichberger, Alexandra; Krefft, Karolina; Vogel, Alfred; Linz, Norbert; Freidank, Sebastian; Hilpert, Andrea; Zimmermann, Inge; Grabner, Günther; Reitsamer, Herbert A

    2013-12-03

    A new 355 nm UV laser was used for corneal flap cutting in an animal model and tested for clinical and morphologic alterations. Corneal flaps were created (Chinchilla Bastards; n = 25) with an UV nanosecond laser at 355 nm (150 kHz, pulse duration 850 ps, spot-size 1 μm, spot spacing 6 × 6 μm, side cut Δz 1 μm; cutting depth 130 μm) and pulse energies of 2.2 or 2.5 μJ, respectively. Following slit-lamp examination, animals were killed at 6, 12, and 24 hours after treatment. Corneas were prepared for histology (hematoxylin and eosin [HE], TUNEL-assay) and evaluated statistically, followed by ultrastructural investigations. Laser treatment was tolerated well, flap lift was easier at 2.5 μJ compared with 2.2 μJ. Standard HE at 24 hours revealed intact epithelium in the horizontal cut, with similar increase in corneal thickness at both energies. Irrespective of energy levels, TUNEL assay revealed comparable numbers of apoptotic cells in the horizontal and vertical cut at 6, 12, and 24 hours, becoming detectable in the horizontal cut as an acellular stromal band at 24 hours. Ultrastructural analysis revealed regular morphology in the epi- and endothelium, while in the stroma, disorganized collagen lamellae were detectable representing the horizontal cut, again irrespective of energy levels applied. This new UV laser revealed no epi- nor endothelial damage at energies feasible for corneal flap cutting. Observed corneal swelling was lower compared with existing UV laser studies, albeit total energy applied here was much higher. Observed loss of stromal keratinocytes is comparable with available laser systems. Therefore, this new laser is suitable for refractive surgery, awaiting its test in a chronic environment.

  8. An ophthalmic solution of a peroxisome proliferator-activated receptor gamma agonist prevents corneal inflammation in a rat alkali burn model

    PubMed Central

    Uchiyama, Masaaki; Masuda, Yukinari; Nagasaka, Shinya; Fukuda, Yuh; Takahashi, Hiroshi

    2013-01-01

    Purpose We clarified the effects of an ophthalmic solution of a peroxisome proliferator-activated receptor gamma (PPARγ) agonist on corneal inflammation and wound healing after alkali burn injury in rats. Methods After alkali exposure, either an ophthalmic solution with 0.1% pioglitazone hydrochloride (the PPARγ group) or vehicle (the vehicle group) was topically applied to the cornea until day 14. Histological, immunohistochemical, and real-time reverse transcription polymerase chain reaction analysis were performed. Results After alkali injury, PPARγ expression increased, with the infiltration of many inflammatory cells. The infiltration of neutrophils and macrophages started from the corneal limbus within 6 h, and developed in the corneal center by day 7, with associated neovascularization. The accumulation of α-smooth muscle actin-positive myofibroblasts and the deposition of type III collagen were noted on day 14. The histological changes were suppressed significantly by treatment with the ophthalmic solution of the PPARγ agonist. In addition, the number of infiltrating M2 macrophages in the cornea was increased by PPARγ agonist treatment. In real-time reverse transcription polymerase chain reaction analysis, the messenger ribonucleic acid expression levels of interleukin-1β (IL-1β), IL-6, IL-8, monocyte chemoattractant protein-1, tumor necrosis factor-α, transforming growth factor beta 1, and vascular endothelial growth factor-A were decreased in the PPARγ group compared to the vehicle group in the early periods of corneal inflammation. Conclusions The ophthalmic solution of the PPARγ agonist inhibited inflammation, decreased the fibrotic reaction, and prevented neovascularization in the cornea from the early phase after alkali burn injury. The ophthalmic solution of the PPARγ agonist may provide a new treatment strategy with useful clinical applications for corneal inflammation and wound healing. PMID:24194635

  9. Comparison of femtosecond laser-assisted descemetic and predescemetic lamellar keratoplasty for keratoconus.

    PubMed

    Lu, Yan; Grisolia, Ana Beatriz Diniz; Ge, Yi-Rui; Xue, Chun-Yan; Cao, Qian; Yang, Li-Ping; Huang, Zhen-Ping

    2017-01-01

    The purpose of this study is to compare the outcomes following femtosecond laser-assisted deep anterior lamellar keratoplasty (DALK) with 75% of stromal dissection (predescemetic group) and femtosecond laser-assisted DALK using big-bubble technique with total stromal resection (descemetic group) for the treatment of keratoconus. Twenty eyes of 17 patients with keratoconus were studied. There were 10 eyes of 9 patients in predescemetic group and 10 eyes of 8 patients in descemetic group. The postoperative best-corrected visual acuity (BCVA), manifest refraction, keratometry, endothelial cell density (ECD), and central corneal thickness (CCT) were analyzed. All surgeries were performed uneventfully. At 1 year after surgery, the BCVA, corneal astigmatism, keratometry, CCT, and ECD between two groups were not statistically significant (all P > 0.05). However, the mean manifest refraction was -9.43 ± 7.44 diopter (D) and -1.03 ± 1.13D in predescemetic and descemetic groups, respectively, which was statistically significant between two groups (P < 0.05). The results of BCVA and corneal astigmatism, keratometry, ECD, and CCT were comparable between two groups. However, the mean postoperative manifest refraction was lower in descemetic group.

  10. In vivo laser confocal microscopic analysis of murine cornea and lens microstructures.

    PubMed

    Yuasa, Masashi; Kobayashi, Akira; Yokogawa, Hideaki; Sugiyama, Kazuhisa

    2008-01-01

    The purpose of the current study is to investigate in vivo microstructures of anterior segments of normal murine eyes by new-generation in vivo laser confocal microscopy. Twenty-six corneas and lenses from 13 mice were analyzed by in vivo laser confocal microscopy. Murine corneal superficial cells formed a polygonal cell pattern, with a mean cell density of 577 +/- 115 cells/mm2 (mean +/- standard deviation). Corneal basal epithelial cells had dark cytoplasm and were closely organized (9,312 +/- 1,777 cells/mm2). Sub-basal nerve fiber bundles were arranged in a whorl pattern, with both clockwise and counter-clockwise patterns. In the stroma, keratocytes were observed as numerous reflective stellate structures. The endothelial cells were organized in a honeycomb pattern (2,463 +/- 292 cells/mm2). Deeper inside the eye, murine lens epithelial cells were organized in a regular pattern (4,168 +/- 636 cells/mm2) and numerous lens fibers were observed. In vivo laser confocal microscopy can provide high-resolution images of all corneal layers and lens structures of mice without sacrificing animals or tissue preparation.

  11. The Role of the Reactive Oxygen Species and Oxidative Stress in the Pathomechanism of the Age-Related Ocular Diseases and Other Pathologies of the Anterior and Posterior Eye Segments in Adults

    PubMed Central

    Nita, Małgorzata; Grzybowski, Andrzej

    2016-01-01

    The reactive oxygen species (ROS) form under normal physiological conditions and may have both beneficial and harmful role. We search the literature and current knowledge in the aspect of ROS participation in the pathogenesis of anterior and posterior eye segment diseases in adults. ROS take part in the pathogenesis of keratoconus, Fuchs endothelial corneal dystrophy, and granular corneal dystrophy type 2, stimulating apoptosis of corneal cells. ROS play a role in the pathogenesis of glaucoma stimulating apoptotic and inflammatory pathways on the level of the trabecular meshwork and promoting retinal ganglion cells apoptosis and glial dysfunction in the posterior eye segment. ROS play a role in the pathogenesis of Leber's hereditary optic neuropathy and traumatic optic neuropathy. ROS induce apoptosis of human lens epithelial cells. ROS promote apoptosis of vascular and neuronal cells and stimulate inflammation and pathological angiogenesis in the course of diabetic retinopathy. ROS are associated with the pathophysiological parainflammation and autophagy process in the course of the age-related macular degeneration. PMID:26881021

  12. The Role of Titanium Surface Microtopography on Adhesion, Proliferation, Transformation, and Matrix Deposition of Corneal Cells.

    PubMed

    Zhou, Chengxin; Lei, Fengyang; Chodosh, James; Paschalis, Eleftherios I

    2016-04-01

    Titanium (Ti) is an excellent implantable biomaterial that can be further enhanced by surface topography optimization. Despite numerous data from orthopedics and dentistry, the effect of Ti surface topography on ocular cells is still poorly understood. In light of the recent adaptation of Ti in the Boston Keratoprosthesis artificial cornea, we attempted to perform an extended evaluation of the effect of Ti surface topography on corneal cell adhesion, proliferation, cytotoxicity, transformation, and matrix deposition. Different surface topographies were generated on medical grade Ti-6Al-4V-ELI (extra-low interstitial), with linearly increased roughness (polished to grit blasted). Biological response was evaluated in vitro using human corneal limbal epithelial (HCLE) cells, stromal fibroblasts (HCF), and endothelial cells (HCEnC). None of the Ti surface topographies caused cytotoxicity to any of the three corneal cell types. However, rough Ti surface inhibited HCLE and HCF cell adhesion and proliferation, while HCEnC proliferation was unaffected. Long-term experiments with HCF revealed that rough Ti surface with R(a) (the arithmetic average of the profile height from the mean line) ≥ 1.15 μm suppressed HCF focal adhesion kinase phosphorylation, changed fibroblast morphology, and caused less aligned and reduced deposition of collagen matrix as compared to smooth Ti (R(a) ≤ 0.08 μm). In the presence of transforming growth factor β1 (TGFβ1) stimulation, rough Ti inhibited alpha-smooth muscle actin (α-SMA) expression and collagen deposition, leading to decreased myofibroblast transformation and disorganization of the collagen fibrils as compared to smooth Ti. This study suggests that Ti surface topography regulates corneal cell behavior in a tissue-dependent manner that varies across the corneal strata. Contrary to the accepted paradigm, smooth surface topography can enhance cell adhesion and proliferation and increase matrix deposition by corneal cells.

  13. Evaluation of Biomechanical Changes in Myopia Patients with Unsatisfactory Corneas After Femto Second-Laser In Situ Keratomileusis (FS-LASIK) Concurrent with Accelerated Corneal Collagen Cross-Linking Using Corvis-ST: Two-Year Follow-Up Results.

    PubMed

    Xu, Weiwei; Tao, Ye; Wang, Liqiang; Huang, Yifei

    2017-07-27

    BACKGROUND Some myopia patients with unsatisfactory corneas consider corneal refractive surgery for different reasons. Accelerated corneal collagen crosslinking (ACXL) is an effective method to enhance the resistance of the cornea. The present investigation was designed to evaluate the changes of biomechanical properties in patients with myopia and thin corneas after femtosecond-laser in situ keratomileusis (FS-LASIK) concurrent with ACXL. MATERIAL AND METHODS A prospective study was designed. A total of 22 eyes of 11 myopia astigmatism patients with unsatisfactory corneas were enrolled. The patients were assigned to femtosecond-laser in situ keratomileusis concurrent with accelerated corneal collagen crosslinking (FS-LASIK-ACXL). The follow-up duration was 24 months. Manifest refraction, uncorrected (UDVA), and corrected distance visual acuity (CDVA), ultra-high-speed camera (Corvis-ST), corneal topography, anterior segment OCT (AS-OCT), Pentacam, and endothelial cell density (ECD) were examined before and after the operation. The corneal biomechanical and refractive data was analyzed using SAS9.3. Data were analyzed through normal distribution test and variance of analysis. The difference was considered as statistically significant when p<0.05. RESULTS The steep K (Ks) values, flat K (Kf) values, average keratometry values (Avek) values, and central corneal thickness (CCT) declined significantly after FS-LASIK-ACXL operation. The values of first applanation length (A1L), the second applanation length (A2L), the first applanation velocity (A1V), the second applanation velocity (A2V), deformation amplitude (DA), highest concavity peak distance (PD), and radius of curvature at the time of highest concavity (HCR) did not show significant difference after the operation. CONCLUSIONS FS-LASIK-ACXL is an effective and safe surgery for improving visual acuity for myopic patients with thin corneas, and it does not increase the risk of iatrogenic keratectasia.

  14. Administration of Menadione, Vitamin K3, Ameliorates Off-Target Effects on Corneal Epithelial Wound Healing Due to Receptor Tyrosine Kinase Inhibition.

    PubMed

    Rush, Jamie S; Bingaman, David P; Chaney, Paul G; Wax, Martin B; Ceresa, Brian P

    2016-11-01

    The antiangiogenic receptor tyrosine kinase inhibitor (RTKi), 3-[(4-bromo-2,6-difluorophenyl)methoxy]-5-[[[[4-(1-pyrrolidinyl) butyl] amino] carbonyl]amino]-4-isothiazolecarboxamide hydrochloride, targets VEGFR2 (half maximal inhibitory concentration [IC50] = 11 nM); however, off-target inhibition of epidermal growth factor receptor (EGFR) occurs at higher concentrations. (IC50 = 5.8 μM). This study was designed to determine the effect of topical RTKi treatment on EGF-mediated corneal epithelial wound healing and to develop new strategies to minimize off-target EGFR inhibition. In vitro corneal epithelial wound healing was measured in response to EGF using a transformed human cell line (hTCEpi cells). In vivo corneal wound healing was assessed using a murine model. In these complementary assays, wound healing was measured in the presence of varying RTKi concentrations. Immunoblot analysis was used to examine EGFR and VEGFR2 phosphorylation and the kinetics of EGFR degradation. An Alamar Blue assay measured VEGFR2-mediated cell biology. Receptor tyrosine kinase inhibitor exposure caused dose-dependent inhibition of EGFR-mediated corneal epithelial wound healing in vitro and in vivo. Nanomolar concentrations of menadione, a vitamin K3 analog, when coadministered with the RTKi, slowed EGFR degradation and ameliorated the inhibitory effects on epithelial wound healing both in vitro and in vivo. Menadione did not alter the RTKi's IC50 against VEGFR2 phosphorylation or its inhibition of VEGF-induced retinal endothelial cell proliferation. An antiangiogenic RTKi exhibited off-target effects on the corneal epithelium that can be minimized by menadione without deleteriously affecting its on-target VEGFR2 blockade. These data indicate that menadione has potential as a topical supplement for individuals suffering from perturbations in corneal epithelial homeostasis, especially as an untoward side effect of kinase inhibitors.

  15. Clinical results with two different pharmaceutical preparations of riboflavin in corneal cross-linking: an 18-month follow up.

    PubMed

    Hashemi, Hassan; Seyedian, Mohammad Amin; Miraftab, Mohammad; Bahrmandy, Hooman; Sabzevari, Araz; Asgari, Soheila

    2015-01-24

    Comparison of long-term clinical results of two different pharmaceutical formulations used in corneal cross-linking (CXL) in keratoconus patients. Sixty eyes of 60 keratoconus patients underwent CXL in two groups. We used riboflavin preparations from Sina Darou, Iran in group A, and Streuli Pharma, Switzerland in group B. Here we made inter-group comparison of changes in vision, refraction, Pentacam indices, corneal biomechanical indices, and endothelial cell count (ECC) 18 months after CXL. Since four patients were lost to follow-up, 56 eyes (28 eyes in each group) were compared. Mean improvement in uncorrected visual acuity (UCVA) was 0.31 ± 0.65 LogMAR (P=0.014) in group A and 0.24 ± 0.62 LogMAR (P=0.082) in group B. Best corrected visual acuity (BCVA) remained quite unchanged in both groups (P=0.774). Mean spherical refractive error reduced by 0.45 ± 1.15 diopter (D) (P=0.041) in group A and 0.27 ± 1.73 D (P=0.458) in group B (P=0.655). Cylinder error and spherical equivalent had a similar trend without any change. Max-K (P=0.006) and mean-K (P=0.044) decreased significantly more in group A compared to group B. The reduction in CCT was significantly more in group A than group B (P=0.004). Q-value was quite unchanged in both groups (P=0.704). The inter-group difference in CH reduction was borderline significant statistically (P=0.057). Changes in corneal resistance factor and endothelial cell count were not significantly different between two groups (P=0.117 and P=0.229). Clinical results of CXL with the domestic preparation of riboflavin are similar to that achieved with the Swiss made product in some aspects, and it is the preferred brand in some other aspects. This study will continue to report longer follow-up results. IRCT201212034333N2.

  16. Anterior segment changes in rabbits after experimental aqueous replacement with various amounts of different perfluorocarbon liquids.

    PubMed

    Stolba, U; Krepler, K; Velikay, M; Binder, S

    1999-06-01

    We evaluated biomicroscopic and histological effects on the anterior segment in the rabbit eye after temporary aqueous substitution with various amounts (0.2 cc and 0.025 cc) of perfluorodecaline (PFD) and perfluorophenanthrene (PFP). A quantity of 0.2 cc of the two perfluorocarbon (PFC) liquids was exchanged simultaneously with about 50% of the aqueous in 15 rabbit eyes each for periods of 1, 2, or 4 weeks. At these points some eyes were enucleated for histological examination. After 2 and 4 weeks the substances were removed from the remaining eyes, which were then followed up for 8-10 weeks. In an additional 8 eyes, 0.025 cc PFD or PFP was injected and left for 8 weeks. Four eyes received balanced salt solution and served as controls. Beside biomicroscopic evaluation and measurement of the intraocular pressure, endothelial cell counts and corneal pachymetry were performed regularly during follow-up. The postoperative results were well comparable for PFD and PFP eyes. Within the first 2 weeks postoperatively corneal edema with endothelial cell loss was observed in both groups. Thereafter regression of the edema started independently of whether the substances were removed or not. IOP was not elevated at any time. At the end of follow-up central corneal thickness was the same as initially. In the inferior corneal endothelium cell density decreased to 45-50% of that in normals. Histologically, vacuoles in the iris and chamber angle were found inferiorly after 4 weeks. Chamber angle closures were present between 5 and 7 o'clock in those eyes where the PFC liquids had been removed after 2 and 4 weeks. Eyes with 0.025 cc PFD or PFP droplets showed vacuolization of the inferior trabecular meshwork 8 weeks postoperatively that was comparable with eyes which had a 50% aqueous replacement for 4 weeks. Control eyes remained unchanged in all aspects. Anterior segment damage caused by PFC liquids is a contact-dependent effect seen in the early observation period. Experimentally there was no difference between the products used or between 2 and 4 weeks' duration of the tamponade.

  17. The long term effect of an iris-supported lens on the endothelium.

    PubMed

    Galin, M A; Dotson, R S; Obstbaum, S A; Tuberville, A W

    1982-01-01

    A retrospective study of 104 eyes that had iris-supported Sputnik intraocular lenses implanted and no surgery in the fellow eye and a separate series of 30 implanted eyes whose second eyes underwent surgery but did not receive implants disclosed that endothelial cell densities in the eyes with implants decreased immediately after surgery and then continued to decrease at the same rate as those of the control eyes. There was no sudden decrease in the endothelial cell counts during follow-up periods ranging from three to seven years. The main cause of large cell losses immediately after surgery, and possibly long-term corneal decompensation, was surgical manipulation rather than the presence of this style of intraocular lens.

  18. Retinoic Acid Engineered Amniotic Membrane Used as Graft or Homogenate: Positive Effects on Corneal Alkali Burns.

    PubMed

    Joubert, Romain; Daniel, Estelle; Bonnin, Nicolas; Comptour, Aurélie; Gross, Christelle; Belville, Corinne; Chiambaretta, Frédéric; Blanchon, Loïc; Sapin, Vincent

    2017-07-01

    Alkali burns are the most common, severe chemical ocular injuries, their functional prognosis depending on corneal wound healing efficiency. The purpose of our study was to compare the benefits of amniotic membrane (AM) grafts and homogenates for wound healing in the presence or absence of previous all-trans retinoic acid (atRA) treatment. Fifty male CD1 mice with reproducible corneal chemical burn were divided into five groups, as follows: group 1 was treated with saline solution; groups 2 and 3 received untreated AM grafts or grafts treated with atRA, respectively; and groups 4 and 5 received untreated AM homogenates or homogenates treated with atRA, respectively. After 7 days of treatment, ulcer area and depth were measured, and vascular endothelial growth factor (VEGF) and matrix metalloproteinase 9 (MMP-9) were quantified. AM induction by atRA was confirmed via quantification of retinoic acid receptor β (RARβ), a well-established retinoic acid-induced gene. Significant improvements of corneal wound healing in terms of ulcer area and depth were obtained with both strategies. No major differences were found between the efficiency of AM homogenates and grafts. This positive action was increased when AM was pretreated with atRA. Furthermore, AM induced a decrease in VEGF and MMP-9 levels during the wound healing process. The atRA treatment led to an even greater decrease in the expression of both proteins. Amnion homogenate is as effective as AM grafts in promoting corneal wound healing in a mouse model. A higher positive effect was obtained with atRA treatment.

  19. Thermo-responsive cell culture carriers based on poly(vinyl methyl ether)—the effect of biomolecular ligands to balance cell adhesion and stimulated detachment

    NASA Astrophysics Data System (ADS)

    Teichmann, Juliane; Nitschke, Mirko; Pette, Dagmar; Valtink, Monika; Gramm, Stefan; Härtel, Frauke V.; Noll, Thomas; Funk, Richard H. W.; Engelmann, Katrin; Werner, Carsten

    2015-08-01

    Two established material systems for thermally stimulated detachment of adherent cells were combined in a cross-linked polymer blend to merge favorable properties. Through this approach poly(N-isopropylacrylamide) (PNiPAAm) with its superior switching characteristic was paired with a poly(vinyl methyl ether)-based composition that allows adjusting physico-chemical and biomolecular properties in a wide range. Beyond pure PNiPAAm, the proposed thermo-responsive coating provides thickness, stiffness and swelling behavior, as well as an apposite density of reactive sites for biomolecular functionalization, as effective tuning parameters to meet specific requirements of a particular cell type regarding initial adhesion and ease of detachment. To illustrate the strength of this approach, the novel cell culture carrier was applied to generate transplantable sheets of human corneal endothelial cells (HCEC). Sheets were grown, detached, and transferred onto planar targets. Cell morphology, viability and functionality were analyzed by immunocytochemistry and determination of transepithelial electrical resistance (TEER) before and after sheet detachment and transfer. HCEC layers showed regular morphology with appropriate TEER. Cells were positive for function-associated marker proteins ZO-1, Na+/K+-ATPase, and paxillin, and extracellular matrix proteins fibronectin, laminin and collagen type IV before and after transfer. Sheet detachment and transfer did not impair cell viability. Subsequently, a potential application in ophthalmology was demonstrated by transplantation onto de-endothelialized porcine corneas in vitro. The novel thermo-responsive cell culture carrier facilitates the generation and transfer of functional HCEC sheets. This paves the way to generate tissue engineered human corneal endothelium as an alternative transplant source for endothelial keratoplasty.

  20. Effects of corneal irregular astigmatism on visual acuity after conventional and femtosecond laser-assisted Descemet's stripping automated endothelial keratoplasty.

    PubMed

    Tomida, Daisuke; Yamaguchi, Takefumi; Ogawa, Akiko; Hirayama, Yumiko; Shimazaki-Den, Seika; Satake, Yoshiyuki; Shimazaki, Jun

    2015-07-01

    To compare short-term outcomes of Descemet's stripping automated endothelial keratoplasty (DSAEK) using a graft prepared with either a femtosecond laser or a microkeratome. Thirty-eight patients underwent DSAEK with grafts prepared with either a femtosecond laser (f-DSAEK; 21 eyes) or a microkeratome (m-DSAEK; 17 eyes). Visual acuity, endothelial cell density, regular astigmatism and irregular astigmatism were compared between the two groups preoperatively and at 1, 3, and 6 months post-operatively. Fourier analysis was conducted to calculate astigmatism of the anterior and posterior surfaces, and total cornea, using anterior segment optical coherence tomography (AS-OCT). Visual acuity (logMAR) improved from 1.20 ± 0.60 to 0.43 ± 0.25 after m-DSAEK (P < 0.001) and from 1.20 ± 0.57 to 0.77 ± 0.33 after f-DSAEK (P = 0.0028) at 6 months following DSAEK. Visual acuity after m-DSAEK was significantly better than after f-DSAEK at 1, 3, and 6 months (P < 0.05). AS-OCT corneal images revealed greater irregularities on the posterior surfaces of f-DSAEK grafts compared to m-DSAEK grafts. Irregular astigmatism of the total cornea and the posterior surface was significantly larger after f-DSAEK than after m-DSAEK, although there was no significant difference in irregular astigmatism of the anterior surface at 6 months. Postoperative visual acuity was significantly correlated with the postoperative irregular astigmatism of the total cornea (r = 0.6657 and P < 0.001) and the anterior (r = 0.416, P = 0.016) and posterior surfaces (r = 0.7046, P < 0.001). Visual outcomes after f-DSAEK were poor compared to conventional m-DSAEK due to an increase in irregular astigmatism caused by posterior surface irregularities.

  1. Rate and Localization of Graft Detachment in Descemet Membrane Endothelial Keratoplasty.

    PubMed

    Maier, Anna-Karina B; Gundlach, Enken; Pilger, Daniel; Rübsam, Anne; Klamann, Matthias K J; Gonnermann, Johannes; Bertelmann, Eckart; Joussen, Antonia M; Torun, Necip

    2016-03-01

    To investigate the rate and localization of graft detachment after Descemet membrane endothelial keratoplasty. Sixty-six consecutive cases operated between June and August 2014 at the Charité-Universitätsmedizin Berlin were examined prospectively 1 week postoperatively. A single masked observer analyzed the rate and localization of graft detachment using optical coherence tomography (OCT), and the rebubbling rate was measured. Localization of graft detachment was correlated to the incision approach. Preoperative data were correlated to the rate of graft detachment and rebubbling. Graft detachment occurred in more than 2 clock hours and with postoperative corneal edema in 33.3% and required rebubbling. In 33.3%, graft detachment occurred in more than 2 clock hours and with postoperative corneal edema and required rebubbling. The mean graft detachment rate was 8.3% per clock hour. A significantly higher graft detachment rate was noted in the inferior clock hours (21.1%, P < 0.0001, 16.7%, P = 0.003). Only higher age of the patient correlated to a higher rate of graft detachment (P = 0.022). No correlation was found between localization of graft detachment and the incision approach (P = 0.615). The graft detachment rate is high after Descemet membrane endothelial keratoplasty, but detachment is usually peripheral, partial and mainly inferior and involves only a few clock hours. Only higher age of the patient is strongly associated with a higher rate of graft detachment. The incision approach is not significantly correlated with the localization of graft detachment. Therefore, the postoperative supine position of the patient seems to be of major importance.Clinical Trial Registration-URL: http://www.clinicaltrials.gov. Unique identifier: NCT02020044.

  2. Evolving indications for and trends in keratoplasty in British Columbia, Canada, from 2002 to 2011: a 10-year review.

    PubMed

    Tan, Johnson C H; Holland, Simon P; Dubord, Paul J; Moloney, Gregory; McCarthy, Martin; Yeung, Sonia N

    2014-03-01

    The aim of this study was to report the evolving indications for keratoplasty and the shift in the type of keratoplasty performed in British Columbia, Canada, over a 10-year period from 2002 to 2011. This was a retrospective database review of all the records of corneal transplant tissues at the Eye Bank of British Columbia, Canada, from January 2002 to December 2011. The patient demographics, indications, and types of transplant performed were analyzed. A total of 4843 corneal transplants were performed in 3742 patients (1968 male and 1774 female) from January 2002 to December 2011. The number of keratoplasties performed ranged from 420 in 2008 to 578 in 2011. The top 4 indications over the 10-year period were Fuchs endothelial dystrophy (FED; 18.9%), aphakic/pseudophakic bullous keratopathy (17.4%), regraft (17.1%), and keratoconus (15.5%). Penetrating keratoplasty (PKP) accounted for 86.5% (4191 transplants) of all keratoplasties performed. Since the introduction of Descemet stripping automated endothelial keratoplasty (DSAEK) in 2007, there was a significant increase in the number of DSAEKs (P < 0.0001) performed and a statistical decline in the number of PKPs (P < 0.0001) performed. Despite only 30 deep anterior lamellar keratoplasties being performed, an increasing trend was observed after 2008 (P = 0.0087). A decreasing trend in PKPs and an increasing trend in DSAEKs were observed for surgeries performed for FED, aphakic/pseudophakic bullous keratopathy, and regraft. FED has become the top indication for performing a keratoplasty over the 10-year period. There was a shift from PKP to DSAEK performed for endothelial failure. Although the number of deep anterior lamellar keratoplasty surgeries was small, there was a significant increasing trend.

  3. Thermo-responsive cell culture carriers based on poly(vinyl methyl ether)-the effect of biomolecular ligands to balance cell adhesion and stimulated detachment.

    PubMed

    Teichmann, Juliane; Nitschke, Mirko; Pette, Dagmar; Valtink, Monika; Gramm, Stefan; Härtel, Frauke V; Noll, Thomas; Funk, Richard H W; Engelmann, Katrin; Werner, Carsten

    2015-08-01

    Two established material systems for thermally stimulated detachment of adherent cells were combined in a cross-linked polymer blend to merge favorable properties. Through this approach poly( N -isopropylacrylamide) (PNiPAAm) with its superior switching characteristic was paired with a poly(vinyl methyl ether)-based composition that allows adjusting physico-chemical and biomolecular properties in a wide range. Beyond pure PNiPAAm, the proposed thermo-responsive coating provides thickness, stiffness and swelling behavior, as well as an apposite density of reactive sites for biomolecular functionalization, as effective tuning parameters to meet specific requirements of a particular cell type regarding initial adhesion and ease of detachment. To illustrate the strength of this approach, the novel cell culture carrier was applied to generate transplantable sheets of human corneal endothelial cells (HCEC). Sheets were grown, detached, and transferred onto planar targets. Cell morphology, viability and functionality were analyzed by immunocytochemistry and determination of transepithelial electrical resistance (TEER) before and after sheet detachment and transfer. HCEC layers showed regular morphology with appropriate TEER. Cells were positive for function-associated marker proteins ZO-1, Na + /K + -ATPase, and paxillin, and extracellular matrix proteins fibronectin, laminin and collagen type IV before and after transfer. Sheet detachment and transfer did not impair cell viability. Subsequently, a potential application in ophthalmology was demonstrated by transplantation onto de-endothelialized porcine corneas in vitro . The novel thermo-responsive cell culture carrier facilitates the generation and transfer of functional HCEC sheets. This paves the way to generate tissue engineered human corneal endothelium as an alternative transplant source for endothelial keratoplasty.

  4. Effect of Descemet Membrane Endothelial Keratoplasty on Color Vision in Patients With Fuchs Dystrophy.

    PubMed

    Price, David A; Price, Marianne O; Lopez, Amanda; Price, Francis W

    2016-08-01

    To assess changes in color discernment after Descemet membrane endothelial keratoplasty (DMEK) in patients with Fuchs endothelial corneal dystrophy (FECD). In this prospective, single-center study, the study group was composed of 26 patients with FECD, aged 46 to 85 years, who underwent DMEK as a single surgical procedure; 24 (92%) had pseudophakic and 2 (8%) had phakic eyes. The patients completed a computerized Farnsworth-Munsell 100-hue color vision test before and 1 month after DMEK. A control group of 14 subjects, aged 57 to 85 years, was tested 1 month after cataract surgery. The median number of errors made by patients who had undergone DMEK on the color vision test improved from 64 (range 24-124) before surgery to 48 (range 10-120) after surgery (P = 0.0053). The post-DMEK scores in the 24 patients with pseudophakic eyes (median = 48, range = 10-120) were comparable to those of an age-matched control group of patients with cataract without corneal abnormalities (median = 53, range = 4-104, P = 0.88). The improvement in color vision was not correlated with the amount of improvement in best corrected visual acuity (r = -0.02, P = 0.91) or with the reduction in central pachymetry (r = -0.08, P = 0.71) after DMEK. Consistent with spontaneous comments from some patients with FECD that colors appear more vivid after DMEK, a comparison of pre- and postoperative color vision scores showed that color discernment usually improved after DMEK (81%). The lack of correlation between color vision improvement and pachymetry reduction leads us to hypothesize that color vision improvement may relate to removal of the guttae associated with FECD.

  5. Thermo-responsive cell culture carriers based on poly(vinyl methyl ether)—the effect of biomolecular ligands to balance cell adhesion and stimulated detachment

    PubMed Central

    Teichmann, Juliane; Nitschke, Mirko; Pette, Dagmar; Valtink, Monika; Gramm, Stefan; Härtel, Frauke V; Noll, Thomas; Funk, Richard H W; Engelmann, Katrin; Werner, Carsten

    2015-01-01

    Two established material systems for thermally stimulated detachment of adherent cells were combined in a cross-linked polymer blend to merge favorable properties. Through this approach poly(N-isopropylacrylamide) (PNiPAAm) with its superior switching characteristic was paired with a poly(vinyl methyl ether)-based composition that allows adjusting physico-chemical and biomolecular properties in a wide range. Beyond pure PNiPAAm, the proposed thermo-responsive coating provides thickness, stiffness and swelling behavior, as well as an apposite density of reactive sites for biomolecular functionalization, as effective tuning parameters to meet specific requirements of a particular cell type regarding initial adhesion and ease of detachment. To illustrate the strength of this approach, the novel cell culture carrier was applied to generate transplantable sheets of human corneal endothelial cells (HCEC). Sheets were grown, detached, and transferred onto planar targets. Cell morphology, viability and functionality were analyzed by immunocytochemistry and determination of transepithelial electrical resistance (TEER) before and after sheet detachment and transfer. HCEC layers showed regular morphology with appropriate TEER. Cells were positive for function-associated marker proteins ZO-1, Na+/K+-ATPase, and paxillin, and extracellular matrix proteins fibronectin, laminin and collagen type IV before and after transfer. Sheet detachment and transfer did not impair cell viability. Subsequently, a potential application in ophthalmology was demonstrated by transplantation onto de-endothelialized porcine corneas in vitro. The novel thermo-responsive cell culture carrier facilitates the generation and transfer of functional HCEC sheets. This paves the way to generate tissue engineered human corneal endothelium as an alternative transplant source for endothelial keratoplasty. PMID:27877823

  6. A Two-Piece Microkeratome-Assisted Mushroom Keratoplasty Improves the Outcomes and Survival of Grafts Performed in Eyes with Diseased Stroma and Healthy Endothelium (An American Ophthalmological Society Thesis)

    PubMed Central

    Busin, Massimo; Madi, Silvana; Scorcia, Vincenzo; Santorum, Paolo; Nahum, Yoav

    2015-01-01

    Purpose: To test the hypothesis that a new microkeratome-assisted penetrating keratoplasty (PK) technique employing transplantation of a two-piece mushroom-shaped graft may result in better visual outcomes and graft survival rates than those of conventional PK. Methods: Retrospective chart review of 96 eyes at low risk and 76 eyes at high risk for immunologic rejection (all with full-thickness central corneal opacity and otherwise healthy endothelium) undergoing mushroom PK between 2004 and 2012 at our Institution. Outcome measures were best-corrected visual acuity (BCVA), refraction, corneal topography, endothelial cell density, graft rejection, and survival probability. Results: Five years postoperatively, BCVA of 20/40 and 20/20 was recorded in 100% and over 50% of eyes, respectively. Mean spherical equivalent of refractive error did not vary significantly over a 5-year period; astigmatism averaged always below 4 diopters, with no statistically significant change over time, and was of the regular type in over 90% of eyes. Endothelial cell density decreased to about 40% of the eye bank count 2 years after mushroom PK and did not change significantly thereafter. Five years postoperatively, probabilities of graft immunologic rejection and graft survival were below 5% and above 95%, respectively. There was no statistically significant difference in endothelial cell loss, graft rejection, and survival probability between low-risk and high-risk subgroups. Conclusions: Refractive and visual outcomes of mushroom PK compare favorably with those of conventional full-thickness keratoplasty. In eyes at high risk for immunologic rejection, mushroom PK provides a considerably higher probability of graft survival than conventional PK. PMID:26538771

  7. Genetic covariance between central corneal thickness and anterior chamber volume: a Hungarian twin study.

    PubMed

    Toth, Georgina Zsofia; Racz, Adel; Tarnoki, Adam Domonkos; Tarnoki, David Laszlo; Szekelyhidi, Zita; Littvay, Levente; Suveges, Ildiko; Nemeth, Janos; Nagy, Zoltan Zsolt

    2014-10-01

    Few, and inconsistent, studies have showed high heritability of some parameters of the anterior segment of the eye; however, no heritability of anterior chamber volume (ACV) has been reported, and no study has been performed to investigate the correlation between the ACV and central corneal thickness (CCT). Anterior segment measurements (Pentacam, Oculus) were obtained from 220 eyes of 110 adult Hungarian twins (41 monozygotic and 14 same-sex dizygotic pairs; 80% women; age 48.6 ± 15.5 years) obtained from the Hungarian Twin Registry. Age- and sex-adjusted heritability of ACV was 85% (bootstrapped 95% confidence interval; CI: 69% to 93%), and 88% for CCT (CI: 79% to 95%). Common environmental effects had no influence, and unshared environmental factors were responsible for 12% and 15% of the variance, respectively. The correlation between ACV and CCT was negative and significant (r ph = -0.35, p < .05), and genetic factors accounted for the covariance significantly (0.934; CI: 0.418, 1.061) based on the bivariate Cholesky decomposition model. These findings support the high heritability of ACV and central corneal thickness, and a strong genetic covariance between them, which underscores the importance of identification of the specific genetic factors and the family risk-based screening of disorders related to these variables, such as open-angle and also angle closure glaucoma and corneal endothelial alterations.

  8. b-FGF induces corneal blood and lymphatic vessel growth in a spatially distinct pattern.

    PubMed

    Hajrasouliha, Amir R; Sadrai, Zahra; Chauhan, Sunil K; Dana, Reza

    2012-07-01

    To study the spatial variances in ligand expression and angiogenic effect in response to the inflammatory response induced by basic fibroblast growth factor (b-FGF). b-FGF micropellets (80 ng) were implanted in the temporal side of the cornea of Balb/c mice. On days 1, 3, and 7, blood (heme-) and lymphangiogenesis were observed by immunofluorescence staining of corneal flat mounts with LYVE-1 and CD31 to identify lymphatic and blood vessels, respectively. A second group of corneas were harvested for quantitative real-time polymerase chain reaction. Each cornea was divided into 2 different areas: (1) pre-pellet area and (2) opposite-pellet area. Expression of vascular endothelial growth factor (VEGF) ligands was evaluated using real-time polymerase chain reaction in each respective zone. Blood vessels grew into the cornea from the pre-pellet area, whereas corneal lymphatic vessels grew from the opposite-pellet area toward the center of the cornea. VEGF-A was upregulated in the pre-pellet, whereas VEGF-D expression was mostly observed in the opposite-pellet area. VEGF-C level increased simultaneously in both areas. A single inducing factor, that is, b-FGF, may simultaneously provoke hemangiogenesis and lymphangiogenesis in different locations of the cornea through differential expression of VEGF ligands. This distinctive spatial pattern should be considered while evaluating the corneal predilection for inflammation beyond that which is directly visible by slit lamp examination.

  9. Differential Effects of Bevacizumab, Ranibizumab, and Aflibercept on the Viability and Wound Healing of Corneal Epithelial Cells.

    PubMed

    Kang, Seungbum; Choi, Hyunsu; Rho, Chang Rae

    2016-12-01

    This study compared the effects of 3 antivascular endothelial growth factor (VEGF) agents (bevacizumab, ranibizumab, and aflibercept) on corneal epithelial cell viability and wound healing using human corneal epithelial cells (HCECs). To determine the cytotoxic effects of anti-VEGF agents on HCECs, HCEC viability was determined at various concentrations of these agents. An in vitro migration assay was used to investigate the migration of HCECs treated with 3 anti-VEGF agents. The protein level of extracellular signal-regulated kinase was used to evaluate the effect of anti-VEGF treatment on cell proliferation. The protein levels of p38 mitogen-activated protein kinase (MAPK) were analyzed by Western blotting to investigate cell migration. After 24 or 48 h of exposure, aflibercept treatment showed no apparent effect on cell viability; however, bevacizumab and ranibizumab treatment decreased cell viability at high concentrations (1 and 2 mg/mL). A migration assay showed that HCEC migration was different among the 3 anti-VEGF treatment groups. Bevacizumab significantly delayed HCEC migration. Western blotting showed that bevacizumab treatment decreased the expression levels of phosphorylated p38 MAPK. Bevacizumab, the most widely used and investigated anti-VEGF agent, decreased epithelial cell migration and viability. Anti-VEGF agents other than bevacizumab might therefore be better for treating corneal neovascularization complicated with epithelial defects.

  10. Patients with Fuchs Endothelial Dystrophy and Cataract Undergoing Descemet Stripping Automated Endothelial Keratoplasty and Phacoemulsification with Intraocular Lens Implant: Staged versus Combined Procedure Outcomes.

    PubMed

    Sykakis, Evripidis; Lam, Fook Chang; Georgoudis, Panagiotis; Hamada, Samer; Lake, Damian

    2015-01-01

    Purpose. To compare the surgical outcomes of staged and combined phacoemulsification with intraocular lens implant (phaco+IOL) and Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with Fuchs' endothelial dystrophy and cataract. Setting. Corneoplastic Unit and Eye Bank, Queen Victoria Hospital, East Grinstead, UK. Methods. Retrospective study of patients who had combined phaco+IOL and DSAEK (group 1) or phaco+IOL followed within 2 months by DSAEK (group 2). Patients who had previous eye surgery or any other ocular comorbidities were excluded. Results. There were 28 eyes in group 1 and 31 in group 2. There were no significant differences in the demographics and corneal tissue characteristics of the two groups. The endothelial disc dislocation and rebubbling rate within 1 week in group 1 was 21.42% and in group 2 was 3.2% (P = 0.04), while the endothelial cell density at 12 months was 1510 ± 433 for group 1 and 1535 ± 482 for group 2 (P = 0.89). The mean 12-month logMAR visual acuity was 0.28 ± 0.24 for group 1 and 0.33 ± 0.15 for group 2 (P = 0.38). Conclusions. Although the combined procedure seems to be associated with a higher complication rate the final outcomes seem to be similar to both methods.

  11. Patients with Fuchs Endothelial Dystrophy and Cataract Undergoing Descemet Stripping Automated Endothelial Keratoplasty and Phacoemulsification with Intraocular Lens Implant: Staged versus Combined Procedure Outcomes

    PubMed Central

    Lam, Fook Chang; Georgoudis, Panagiotis; Hamada, Samer; Lake, Damian

    2015-01-01

    Purpose. To compare the surgical outcomes of staged and combined phacoemulsification with intraocular lens implant (phaco+IOL) and Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with Fuchs' endothelial dystrophy and cataract. Setting. Corneoplastic Unit and Eye Bank, Queen Victoria Hospital, East Grinstead, UK. Methods. Retrospective study of patients who had combined phaco+IOL and DSAEK (group 1) or phaco+IOL followed within 2 months by DSAEK (group 2). Patients who had previous eye surgery or any other ocular comorbidities were excluded. Results. There were 28 eyes in group 1 and 31 in group 2. There were no significant differences in the demographics and corneal tissue characteristics of the two groups. The endothelial disc dislocation and rebubbling rate within 1 week in group 1 was 21.42% and in group 2 was 3.2% (P = 0.04), while the endothelial cell density at 12 months was 1510 ± 433 for group 1 and 1535 ± 482 for group 2 (P = 0.89). The mean 12-month logMAR visual acuity was 0.28 ± 0.24 for group 1 and 0.33 ± 0.15 for group 2 (P = 0.38). Conclusions. Although the combined procedure seems to be associated with a higher complication rate the final outcomes seem to be similar to both methods. PMID:26064669

  12. Histologically proven epithelial ingrowth in failed Descemet stripping automated endothelial keratoplasty (DSAEK) managed by repeat DSAEK

    PubMed Central

    Ghosh, Saurabh; Bonshek, Richard; Morgan, Stephen J

    2013-01-01

    Purpose To report a case of corneal graft failure due to epithelial ingrowth after an uneventful combined Descemet stripping automated endothelial keratoplasty (DSAEK) and phacoemulsification cataract surgery with intraocular lens implant treated successfully with a repeat DSAEK. Methods A 77-year-old male patient underwent combined DSAEK and phacoemulsification with intraocular lens implant implantation for Fuchs’ endothelial dystrophy plus cataract in the right eye. The donor cornea was cut on the Moria ALTK system and introduced using a suture pull-through technique. After an episode of endothelial rejection, the graft failed, with signs suggesting epithelial ingrowth. It was stripped from the host cornea using a Descemet’s membrane stripper, and a Simcoe irrigation-aspiration cannula was used to remove all traces of interface material. The excised lenticule was examined histologically using a hematoxylin and eosin stain. Result The patient regained and maintained excellent visual acuity with no sign of recurrence of epithelial ingrowth. Histopathological evaluation of the donor tissue of the first graft showed epithelial ingrowth on the stromal surface of the graft and very few endothelial cells, in keeping with the diagnosis of graft failure. Conclusion Epithelial ingrowth is a possible cause of endothelial graft failure, but histologically proven cases are rare. Surgical intervention can achieve successful clearance, with the potential for cure and an excellent outcome. PMID:23754868

  13. Treatment of alkali-injured cornea by cyclosporine A-loaded electrospun nanofibers - An alternative mode of therapy.

    PubMed

    Cejkova, Jitka; Cejka, Cestmir; Trosan, Peter; Zajicova, Alena; Sykova, Eva; Holan, Vladimir

    2016-06-01

    In this study we tried to develop a new approach to suppress inflammation and neovascularization in the alkali-injured rabbit cornea. For this reason Cyclosporine A (CsA)-loaded electrospun nanofibers were transferred onto the ocular surface injured with alkali (0.25 N NaOH). Damaged corneas were divided into the following groups: untreated, treated with CsA eye drops, treated with nanofibers drug-free and treated with CsA-loaded nanofibers. Healthy rabbit corneas served as controls. Drug-free nanofibers and CsA-loaded nanofibers were transferred onto the damaged corneal surface immediately after the injury and sutured to conjunctiva. On day five after the injury the nanofibers were removed. The animals from all groups were sacrificed on day twelve after the injury. The extent of the inflammatory reaction and corneal healing were examined macroscopically, immunohistochemically and biochemically. The central corneal thickness was measured using an ultrasonic pachymeter. When compared with untreated injured corneas, injured corneas treated with drug-free nanofibers or injured corneas treated with CsA eye drops, the number of CD3-positive cells (T lymphocytes) and the production of pro-inflammatory cytokines were strongly reduced in corneas treated with CsA-loaded nanofibers, which was associated with the significantly decreased expression of matrix metalloproteinase 9, inducible nitric oxide synthase, vascular endothelial growth factor and active caspase-3. CsA-loaded nanofibers effectively suppressed corneal inflammation and corneal neovascularization. Central corneal thickness restored to levels before injury only in corneas treated with CsA-loaded nanofibers. Corneal transparency was highly restored in these corneas. It is suggested that the beneficial effect of CsA-loaded nanofibers was associated with the continuous release of CsA from nanofibers and continuous affection of damaged cornea by CsA. The suture of nanofibers to conjunctiva and the closed eyes contributed to beneficial corneal healing. This is in contrast to CsA eye drops, which are quickly washed from the ocular surface and the contact of CsA with the damaged cornea was limited. In conclusion, the approach with CsA-loaded nanofibers could represent an effective alternative mode of therapy for corneal chemical burns. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Intraocular Lens Opacification After Endothelial Keratoplasty as Analyzed by Environmental Scanning Electron Microscopy.

    PubMed

    Verdaguer, Paula; Gris, Oscar; Casaroli-Marano, Ricardo P; Elies, Daniel; Muñoz-Gutierrez, Gerardo; Güell, Jose L

    2015-08-01

    To describe a case of hydrophilic intraocular lens (IOL) opacification based on IOL analysis after Descemet stripping automated endothelial keratoplasty. A 60-year-old woman had uneventful phacoemulsification after the implantation of a hydrophilic IOL (Akreos-Adapt; Bausch & Lomb) into both eyes. Because of postoperative corneal decompensation in the right eye, 2 Descemet stripping automated endothelial keratoplasty operations were performed within 1 year. After the second procedure, the graft was not well attached, requiring an intracameral injection of air on day 3. After 1 year, opacification was observed on the superior 2/3 of the anterior surface of the IOL, along with a significant decrease in visual acuity. The IOL was explanted 6 months after the opacification. Environmental scanning electron microscopy followed by x-ray microanalysis revealed an organic biofilm on the surface of the IOL. To our knowledge, this is the first reported case in which the material deposited on the lens is organic rather than calcific.

  15. Effect of incision width on graft survival and endothelial cell loss after DSAEK

    PubMed Central

    Price, Marianne O.; Bidros, Maria; Gorovoy, Mark; Price, Francis W.; Benetz, Beth A.; Menegay, Harry J.; Debanne, Sara M.; Lass, Jonathan H.

    2009-01-01

    Purpose To assess the effect of incision width (5.0 and 3.2 mm) on graft survival and endothelial cell loss six months and one year after Descemet stripping automated endothelial keratoplasty (DSAEK). Methods One hundred sixty-seven subjects with endothelial decompensation from a moderate-risk condition (principally Fuchs’ dystrophy or pseudophakic corneal edema) underwent DSAEK by two experienced surgeons. The donor was folded over and inserted with single point fixation forceps. This retrospective analysis assessed graft survival, complications, and endothelial cell loss, which was calculated from baseline donor and 6-month and 1-year postoperative central endothelial images evaluated by an independent specular microscopy reading center. Results No primary graft failures occurred in either group. One-year graft survival rates were comparable (98% vs. 97%) in the 5.0- and 3.2-mm groups, respectively (P=1.0). Complications included graft dislocation, graft rejection episodes, and elevated intraocular pressure and occurred at similar rates in both groups (P ≥ 0.28). Pupillary block glaucoma did not occur in either group. Mean baseline donor endothelial cell density did not differ: 2782 cells/mm2 in the 5.0-mm (n=64) and 2784 cells/mm2 in the 3.2-mm (n=103) groups. Percent endothelial cell loss was 27±20% (n=55) vs. 40±22% (n=71; 6 months) and 31±19% (n=45) vs. 44±22% (n=62; 12 months) in the 5.0-mm and 3.2-mm incision groups, respectively (both P<0.001). Conclusions One year after DSAEK, overall graft success was comparable for the two groups; however, the 5.0-mm incision width resulted in substantially lower endothelial cell loss at 6 and 12 months. PMID:20299973

  16. Soybean agglutinin binding to corneal endothelial cell surfaces disrupts in situ monolayer integrity and actin organization and interferes with wound repair.

    PubMed

    Gordon, Sheldon R; Wood, Meredith

    2009-03-01

    Rat corneal endothelium demonstrates cell-surface soybean agglutinin (SBA) binding during organ-culture or injury. When organ-cultured in medium containing SBA, the endothelial monolayer is disrupted because of cell-cell and cell-matrix alterations. SBA binding disorganizes the circumferential microfilament bundles (CMBs), an effect that is partially prevented by phallacidin preincubation. This disruption is reversible if tissues are returned to standard culture medium. Serum heightens SBA binding, whereas puromycin prevents it. Neither actinomycin D nor alpha-amanitin inhibits SBA binding, suggesting that SBA-binding protein(s) may be post-transcriptionally regulated. During injury-induced cell migration in the presence of SBA, cellular processes are blunted and fail to extend significantly outward. By 72 h post-injury, cells of SBA-treated tissues repopulate the wound but demonstrate little association with neighboring cells. Cells migrating in the presence of N-acetylgalactosamine appear normal but also fail to reassociate with other cells in the jury zone. Immunofluorescent staining for ZO-1 reveals punctuate patterns in cells of control tissues, whereas neither SBA- nor N-acetylgalactosamine-treated tissues exhibit ZO-1 staining. Terminal N-acetylgalactosamine removal fails to affect cell morphology, actin organization, or migration but prevents lectin binding. Our results suggest that SBA binding reflects the synthesis of a stress-induced protein(s) that may play a role in reestablishing cell-cell relationships during monolayer reorganization following injury.

  17. Effect of amniotic fluid on the in vitro culture of human corneal endothelial cells.

    PubMed

    Feizi, Sepehr; Soheili, Zahra-Soheila; Bagheri, Abouzar; Balagholi, Sahar; Mohammadian, Azam; Rezaei-Kanavi, Mozhgan; Ahmadieh, Hamid; Samiei, Shahram; Negahban, Kambiz

    2014-05-01

    The present study was designed to evaluate the effects of human amniotic fluid (HAF) on the growth of human corneal endothelial cells (HCECs) and to establish an in vitro method for expanding HCECs. HCECs were cultured in DMEM-F12 supplemented with 20% fetal bovine serum (FBS). Confluent monolayer cultures were trypsinized and passaged using either FBS- or HAF-containing media. Cell proliferation and cell death ELISA assays were performed to determine the effect of HAF on cell growth and viability. The identity of the cells cultured in 20% HAF was determined using immunocytochemistry (ICC) and real-time reverse transcription polymerase chain reaction (RT-PCR) techniques to evaluate the expression of factors that are characteristic of HCECs, including Ki-67, Vimentin, Na+/K+-ATPase and ZO-1. HCEC primary cultures were successfully established using 20% HAF-containing medium, and these cultures demonstrated rapid cell proliferation according to the cell proliferation and death ELISA assay results. The ICC and real time RT-PCR results indicated that there was a higher expression of Na+/K+-ATPase and ZO-1 in the 20% HAF cell cultures compared with the control (20% FBS) (P < 0.05). The 20% HAF-containing medium exhibited a greater stimulatory effect on HCEC growth and could represent a potential enriched supplement for HCEC regeneration studies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Control of Cross Talk between Angiogenesis and Inflammation by Mesenchymal Stem Cells for the Treatment of Ocular Surface Diseases.

    PubMed

    Li, Fei; Zhao, Shao-Zhen

    2016-01-01

    Angiogenesis is beneficial in the treatment of ischemic heart disease and peripheral artery disease. However, it facilitates inflammatory cell filtration and inflammation cascade that disrupt the immune and angiogenesis privilege of the avascular cornea, resulting in ocular surface diseases and even vision loss. Although great progress has been achieved, healing of severe ocular surface injury and immunosuppression of corneal transplantation are the most difficult and challenging step in the treatment of ocular surface disorders. Mesenchymal stem cells (MSCs), derived from various adult tissues, are able to differentiate into different cell types such as endothelial cells and fat cells. Although it is still under debate whether MSCs could give rise to functional corneal cells, recent results from different study groups showed that MSCs could improve corneal disease recovery through suppression of inflammation and modulation of immune cells. Thus, MSCs could become a promising tool for ocular surface disorders. In this review, we discussed how angiogenesis and inflammation are orchestrated in the pathogenesis of ocular surface disease. We overviewed and updated the knowledge of MSCs and then summarized the therapeutic potential of MSCs via control of angiogenesis, inflammation, and immune response in the treatment of ocular surface disease.

  19. Ophthalmic parameters in adult lowland paca (Cuniculus paca) raised in captivity.

    PubMed

    Balthazar da Silveira, Camila P; Lima, Tiago B; Crivelaro, Roberta M; de Lacerda, Luciana C C; Pádua, Ivan R M; Renzo, Roberta; de Barros Sobrinho, Alexandre A F; Oliveira, Fabrício S; Aldrovani, Marcela; Laus, José L

    2018-01-01

    To investigate the ophthalmic parameters of lowland pacas, including the anatomic features, tear production, intraocular pressure, central corneal thickness, and morphology of the corneal endothelium. Thirteen adult, anesthetized Cuniculus paca. Eyes were evaluated using slit-lamp biomicroscopy, the Schirmer tear test I, digital applanation tonometry, binocular indirect ophthalmoscopy, and noncontact specular microscopy. The biomicroscopy findings showed blue/brown pigmented bulbar conjunctivae, well-developed cilia (only in the upper eyelid margin), superior and inferior lacrimal puncta, brown irides, round pupils, and vestiges of the nictitating membrane. The results of the Schirmer tear test I revealed (mean ± SD) a lacrimation rate of 4.10 ± 0.44 mm/min. The intraocular pressure was 6.34 ± 0.43 mmHg. Central corneal thickness measured by specular microscopy was 0.35 ± 0.01 mm. The mean values of density, hexagonality, and the area of the endothelial cells were 2083.15 ± 42.47 cells/mm 2 , 67.07 ± 3.30%, and 486.30 ± 9.56 μm 2 , respectively. The ocular parameters defined in this study may be used for reference in future studies and might also contribute to therapeutic approaches appropriate to this species. © 2017 American College of Veterinary Ophthalmologists.

  20. A robotic platform for laser welding of corneal tissue

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Micheletti, Filippo; Magni, Giada; Pini, Roberto; Menabuoni, Luca; Leoni, Fabio; Magnani, Bernardo

    2017-07-01

    Robotic surgery is a reality in several surgical fields, such as in gastrointestinal surgery. In ophthalmic surgery the required high spatial precision is limiting the application of robotic system, and even if several attempts have been designed in the last 10 years, only some application in retinal surgery were tested in animal models. The combination of photonics and robotics can really open new frontiers in minimally invasive surgery, improving the precision, reducing tremor, amplifying scale of motion, and automating the procedure. In this manuscript we present the preliminary results in developing a vision guided robotic platform for laser-assisted anterior eye surgery. The robotic console is composed by a robotic arm equipped with an "end effector" designed to deliver laser light to the anterior corneal surface. The main intended application is for laser welding of corneal tissue in laser assisted penetrating keratoplasty and endothelial keratoplasty. The console is equipped with an integrated vision system. The experiment originates from a clear medical demand in order to improve the efficacy of different surgical procedures: when the prototype will be optimized, other surgical areas will be included in its application, such as neurosurgery, urology and spinal surgery.

  1. Wound-Induced Polyploidization: Regulation by Hippo and JNK Signaling and Conservation in Mammals.

    PubMed

    Losick, Vicki P; Jun, Albert S; Spradling, Allan C

    2016-01-01

    Tissue integrity and homeostasis often rely on the proliferation of stem cells or differentiated cells to replace lost, aged, or damaged cells. Recently, we described an alternative source of cell replacement- the expansion of resident, non-dividing diploid cells by wound-induced polyploidization (WIP). Here we show that the magnitude of WIP is proportional to the extent of cell loss using a new semi-automated assay with single cell resolution. Hippo and JNK signaling regulate WIP; unexpectedly however, JNK signaling through AP-1 limits rather than stimulates the level of Yki activation and polyploidization in the Drosophila epidermis. We found that polyploidization also quantitatively compensates for cell loss in a mammalian tissue, mouse corneal endothelium, where increased cell death occurs with age in a mouse model of Fuchs Endothelial Corneal Dystrophy (FECD). Our results suggest that WIP is an evolutionarily conserved homeostatic mechanism that maintains the size and synthetic capacity of adult tissues.

  2. [Construction of injectable tissue engineered adipose tissue with fibrin glue scaffold and human adipose-derived stem cells transfected by lentivirus vector expressing hepatocyte growth factor].

    PubMed

    Zhu, Yuanzheng; Yi, Yangyan; Yang, Shuifa; Zhang, Jing; Wu, Shu; Wang, Zhaohui

    2017-09-01

    To discuss the possibility of constructing injectable tissue engineered adipose tissue, and to provide a new approach for repairing soft tissue defects. Human adipose-derived stem cells (hADSCs) were extracted from the lipid part of human liposuction aspirate by enzymatic digestion and identified by morphological observation, flow cytometry, and adipogenic induction. The hADSCs underwent transfection by lentivirus vector expressing hepatocyte growth factor and green fluorescent protein (HGF-GFP-LVs) of different multiplicity of infection (MOI, 10, 30, 50, and 100), the transfection efficiency was calculated to determine the optimum MOI. The hADSCs transfected by HGF-GFP-LVs of optimal MOI and being adipogenic inducted were combined with injectable fibrin glue scaffold, and were injected subcutaneously into the right side of the low back of 10 T-cell deficiency BALB/c female nude mice (transfected group); non-HGF-GFP-LVs transfected hADSCs (being adipogenic inducted) combined with injectable fibrin glue scaffold were injected subcutaneously into the left side of the low back (untransfected group); and injectable fibrin glue scaffold were injected subcutaneously into the middle part of the neck (blank control group); 0.4 mL at each point. Twelve weeks later the mice were killed and the implants were taken out. Gross observation, wet weight measurement, HE staining, GFP fluorescence labeling, and immunofluorescence staining were performed to assess the in vivo adipogenic ability of the seed cells and the neovascularization of the grafts. The cultured cells were identified as hADSCs. Poor transfection efficiency was observed in MOI of 10 and 30, the transfection efficiency of MOI of 50 and 100 was more than 80%, so the optimum MOI was 50. Adipose tissue-like new-born tissues were found in the injection sites of the transfected and untransfected groups after 12 weeks of injection, and no new-born tissues was found in the blank control group. The wet-weight of new-born tissue in the transfected group [(32.30±4.06) mg] was significantly heavier than that of the untransfected group [(25.27±3.94) mg] ( t =3.929, P =0.001). The mature adipose cells in the transfected group [(126.93±5.36) cells/field] were significantly more than that in the untransfected group [(71.36±4.52) cells/field] ( t =30.700, P =0.000). Under fluorescence microscopy, some of the single cell adipocytes showed a network of green fluorescence, indicating the presence of GFP labeled exogenous hADSCs in the tissue. The vascular density of new-born tissue of the transfected group [(16.37±2.76)/field] was significantly higher than that of the untransfected group [(9.13±1.68)/field] ( t =8.678, P =0.000). The hADSCs extracted from the lipid part after liposuction can be used as seed cells. After HGF-GFP-LVs transfection and adipose induction, the hADSCs combined with injectable fibrin glue scaffold can construct mature adipose tissue in vivo , which may stimulate angiogenesis, and improve retention rate of new-born tissue.

  3. Validation of an endothelial roll preparation for Descemet Membrane Endothelial Keratoplasty by a cornea bank using "no touch" dissection technique.

    PubMed

    Marty, Anne-Sophie; Burillon, Carole; Desanlis, Adeline; Damour, Odile; Kocaba, Viridiana; Auxenfans, Céline

    2016-06-01

    Descemet Membrane Endothelial Keratoplasty (DMEK) selectively replaces the damaged posterior part of the cornea. However, the DMEK technique relies on a manually-performed dissection that is time-consuming, requires training and presents a potential risk of endothelial graft damages leading to surgery postponement when performed by surgeons in the operative room. To validate precut corneal tissue preparation for DMEK provided by a cornea bank in order to supply a quality and security precut endothelial tissue. The protocol was a technology transfer from the Netherlands Institute for Innovative Ocular Surgery (NIIOS) to Lyon Cornea Bank, after formation in NIIOS to the DMEK "no touch" dissection technique. The technique has been validated in selected conditions (materials, microscope) and after a learning curve, cornea bank technicians prepared endothelial tissue for DMEK. Endothelial cells densities (ECD) were evaluated before and after preparation, after storage and transport to the surgery room. Microbiological and histological controls have been done. Twenty corneas were manually dissected; 18 without tears. Nineteen endothelial grafts formed a double roll. The ECD loss after cutting was 3.3 % (n = 19). After transportation 7 days later, we found an ECD loss of 25 % (n = 12). Three days after cutting and transportation, we found 2.1 % of ECD loss (n = 7). Histology found an endothelial cells monolayer lying on Descemet membrane. The mean thickness was 12 ± 2.2 µm (n = 4). No microbial contamination was found (n = 19). Endothelial roll stability has been validated at 3 days in our cornea bank. Cornea bank technicians trained can deliver to surgeons an ECD controlled, safety and ready to use endothelial tissue, for DMEK by "no touch" technique, allowing time saving, quality and security for surgeons.

  4. A practical femtosecond laser procedure for DLEK endothelial transplantation: cadaver eye histology and topography.

    PubMed

    Terry, Mark A; Ousley, Paula J; Will, Brian

    2005-05-01

    The manual dissection technique for deep lamellar endothelial keratoplasty (DLEK) surgery is technically difficult and may not be smooth enough for consistently optimal postoperative vision. We evaluated the feasibility and efficacy of using a femtosecond laser to perform the dissections in the DLEK procedure. The Intralase femtosecond laser (with standard LASIK surgery spot settings) was used to create a 9.4-mm wide, 400-microm deep lamellar pocket dissection and a 5.0-mm wide side cut near-exit incision in 10 "recipient" whole cadaver eyes and in 10 "donor" cadaver corneal-scleral caps mounted onto an artificial anterior chamber. Recipient and donor disks were resected with special scissors, and the donor tissue was transplanted using the small incision (5.0-mm) DLEK technique. Topography of the recipient eyes was measured pre- and postlaser dissection, and the recipient and donor tissues were sent for scanning electron microscopy (SEM) analysis of the smoothness of the dissections. Successful lamellar dissections were obtained in all tissues. The mean recipient topographic corneal curvature postoperatively was 43.3 +/- 1.7 diopters, which was not a significant change from the preoperative curvature of 44.0 +/- 0.8 diopters (P = 0.430). The mean recipient topographic astigmatism postoperatively was 1.7 +/- 0.8 diopters, which was not a significant change from the preoperative recipient astigmatism of 1.6 +/- 0.7 diopters (P = 0.426). Comparison of the histology of the laser-formed stromal dissections by scanning electron microscopy, however, did not appear significantly better than histology after manual DLEK dissections in either the recipient or the donor tissues. A femtosecond laser can create the lamellar dissections for the DLEK procedure, making this procedure easier and faster. As in the manual technique, corneal topography is unchanged by this surgery. More work will need to be done, however, to optimize the laser settings to provide even smoother interface surfaces.

  5. Protective effect and molecular mechanism of liquiritin on oxybuprocaine-induced apoptosis of human corneal endothelial cells

    PubMed Central

    Li, Dan; Zhang, Peng

    2018-01-01

    This study was designed to investigate the protective effect and possible molecular mechanism of liquiritin on oxybuprocaine-induced apoptosis of human corneal endothelial cells (HCECs). In this study, the effect of oxybuprocaine on the proliferation of HCEC-12 was detected using cell counting kit-8 (CCK-8). The inductive effect of oxybuprocaine on HCEC-12 apoptosis and protective effect of liquiritin against oxybuprocaine-induced HCEC-12 apoptosis were tested by Annexin V/propidium iodide (PI) staining and flow cytometry. The production of reactive oxygen species (ROS) was analyzed by 2,7-dichlorodi-hydrofluorescein diacetate (DCFH-DA) staining and fluorescent-activated cell sorting (FACS), and the expression of nuclear factor-κB (NF-κB) p65 and apoptosis-related proteins, caspase-3 and Bax, was determined by western blot analysis. Our results show that liquiritin resisted the inhibitory effect of oxybuprocaine on the proliferation of HCEC-12, and cell activity had the most significant increase in pretreatment with liquiritin group in the concentration of 8 mg/ml; compared with that in oxybuprocaine group. Apoptosis in pretreatment with liquiritin was distinctly decreased and liquiritin resisted the production of ROS in HCEC-12 induced by oxybuprocaine. Investigation of molecular mechanism revealed that the pretreatment with liquiritin and pyrrolidinedithiocarbamic acid (PDTC) obviously blocked the expression of NF-κB p65 in nuclear protein increased by oxybuprocaine and the expression levels of total proteins, caspase-3 and Bax.Moreover, tumor necrosis factor-α (TNF-α) blocked the inhibitory effect of liquiritin on the expression of NF-κB p65 in nuclear protein and total proteins, caspase-3 and Bax, thus obstructing the protective effect of liquiritin on corneal epithelial cells. The results of this study indicated that liquiritin reduces the expression of apoptosis protein and increases the expression of anti-apoptotic protein through inhibiting NF-κB signal pathway, thus resisting HCEC-12 apoptosis induced by oxybuprocaine. PMID:29545865

  6. Protective effect and molecular mechanism of liquiritin on oxybuprocaine-induced apoptosis of human corneal endothelial cells.

    PubMed

    Li, Dan; Zhang, Peng

    2018-04-01

    This study was designed to investigate the protective effect and possible molecular mechanism of liquiritin on oxybuprocaine-induced apoptosis of human corneal endothelial cells (HCECs). In this study, the effect of oxybuprocaine on the proliferation of HCEC-12 was detected using cell counting kit-8 (CCK-8). The inductive effect of oxybuprocaine on HCEC-12 apoptosis and protective effect of liquiritin against oxybuprocaine-induced HCEC-12 apoptosis were tested by Annexin V/propidium iodide (PI) staining and flow cytometry. The production of reactive oxygen species (ROS) was analyzed by 2,7-dichlorodi-hydrofluorescein diacetate (DCFH-DA) staining and fluorescent-activated cell sorting (FACS), and the expression of nuclear factor-κB (NF-κB) p65 and apoptosis-related proteins, caspase-3 and Bax, was determined by western blot analysis. Our results show that liquiritin resisted the inhibitory effect of oxybuprocaine on the proliferation of HCEC-12, and cell activity had the most significant increase in pretreatment with liquiritin group in the concentration of 8 mg/ml; compared with that in oxybuprocaine group. Apoptosis in pretreatment with liquiritin was distinctly decreased and liquiritin resisted the production of ROS in HCEC-12 induced by oxybuprocaine. Investigation of molecular mechanism revealed that the pretreatment with liquiritin and pyrrolidinedithiocarbamic acid (PDTC) obviously blocked the expression of NF-κB p65 in nuclear protein increased by oxybuprocaine and the expression levels of total proteins, caspase-3 and Bax.Moreover, tumor necrosis factor-α (TNF-α) blocked the inhibitory effect of liquiritin on the expression of NF-κB p65 in nuclear protein and total proteins, caspase-3 and Bax, thus obstructing the protective effect of liquiritin on corneal epithelial cells. The results of this study indicated that liquiritin reduces the expression of apoptosis protein and increases the expression of anti-apoptotic protein through inhibiting NF-κB signal pathway, thus resisting HCEC-12 apoptosis induced by oxybuprocaine.

  7. [Management of corneal endothelial decompensation with Descemet's membrane endothelial keratoplasty in a patient with Ahmed glaucoma valve implant].

    PubMed

    Röck, T; Bartz-Schmidt, K-U; Röck, D; Yoeruek, E

    2014-05-01

    Currently, the main causes for developing bullous keratopathy are from problems related to intraocular surgery, trauma, infection, Fuchs' endothelial dystrophy and chronically elevated intraocular pressure. In the 1990s penetrating keratoplasty was once considered the therapy of choice for treatment of bullous keratopathy but in recent years it has been replaced by posterior lamellar keratoplasty. The Descemet membrane endothelial keratoplasty (DMEK) procedure represents the final development of posterior lamellar keratoplasty. The question now arises whether DMEK can be used in patients with bullous keratopathy and Ahmed glaucoma valve implant. A 72-year-old man was referred to our hospital for further evaluation with the diagnosis of bullous keratopathy and pseudoexfoliative glaucoma. The bullous keratopathy was caused by a variety of previous operations as well as decompensation of intraocular pressure. This article describes the therapy of bullous keratopathy by DMEK with existing Ahmed glaucoma valve implant. After surgery the cornea became clear and the best-corrected visual acuity improved from hand movement to 0.2. The intraocular pressure remained normal (10-14 mmHg) without antiglaucoma medication and the endothelial cell count decreased only slightly over a follow-up of 13 months. No complications were encountered. The DMEK surgical procedure seems to be possible in patients with Ahmed glaucoma valve implant and endothelial decompensation. However, further studies with a larger number of patients should follow to validate the replacement of penetrating keratoplasty and other posterior lamellar procedures by DMEK.

  8. Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines

    PubMed Central

    Ataş, Mustafa; Demircan, Süleyman; Karatepe Haşhaş, Arzu Seyhan; Gülhan, Ahmet; Zararsız, Gökmen

    2014-01-01

    AIM To compare and evaluate the phacoemulsification parameters and postoperative endothelial cell changes of two different phacoemulsification machines, each with different modes, but also to assess the relationship between postoperative endothelial cell loss and the phacoemulsification parameters, as well as the other factors in both groups. METHODS This prospective observational study was comprised of consecutive eligible cataract patients operated with phacoemulsification technique performed by the same surgeon using either a WHITESTAR Signature Ellips FX (transversal, group 1) or Infiniti OZil IP (torsional, group 2) machine. RESULTS The study included 86 patients. Baseline characteristics in the groups were similar. The median nuclear sclerosis grade was 3 (2-4) in the first group and 2 (2-4) in the second group (P=0.265). Both groups had similar phacoemulsification needle times (group 1: 60.63±36 s; group 2: 55.98±30 s; P=0.789). The percentage of endothelial cell loss 30d after surgery ranged from 3% to 15% with a median of 7% in group 1, and from 2% to 13% with a median of 6% in group 2; however, there was no statistically significant difference between the groups (P=0.407). Hexagonality (P=0.794) and the coefficient of variation (CV; P=0.142) did not differ significantly between the groups before and 30d after surgery. A significant positive correlation was found between the endothelial cell loss and nuclear sclerosis grade (group 1: P<0.001; group 2: P<0.001) and between the endothelial cell loss and average phacoemulsification power (group 1: P=0.007; group 2: P=0.008). CONCLUSION Both of these machines were efficient, with similar endothelial cell loss. This endothelial cell loss was related to the increased nuclear sclerosis grade and increased phacoemulsification power. PMID:25349800

  9. Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines.

    PubMed

    Ataş, Mustafa; Demircan, Süleyman; Karatepe Haşhaş, Arzu Seyhan; Gülhan, Ahmet; Zararsız, Gökmen

    2014-01-01

    To compare and evaluate the phacoemulsification parameters and postoperative endothelial cell changes of two different phacoemulsification machines, each with different modes, but also to assess the relationship between postoperative endothelial cell loss and the phacoemulsification parameters, as well as the other factors in both groups. This prospective observational study was comprised of consecutive eligible cataract patients operated with phacoemulsification technique performed by the same surgeon using either a WHITESTAR Signature Ellips FX (transversal, group 1) or Infiniti OZil IP (torsional, group 2) machine. The study included 86 patients. Baseline characteristics in the groups were similar. The median nuclear sclerosis grade was 3 (2-4) in the first group and 2 (2-4) in the second group (P=0.265). Both groups had similar phacoemulsification needle times (group 1: 60.63±36 s; group 2: 55.98±30 s; P=0.789). The percentage of endothelial cell loss 30d after surgery ranged from 3% to 15% with a median of 7% in group 1, and from 2% to 13% with a median of 6% in group 2; however, there was no statistically significant difference between the groups (P=0.407). Hexagonality (P=0.794) and the coefficient of variation (CV; P=0.142) did not differ significantly between the groups before and 30d after surgery. A significant positive correlation was found between the endothelial cell loss and nuclear sclerosis grade (group 1: P<0.001; group 2: P<0.001) and between the endothelial cell loss and average phacoemulsification power (group 1: P=0.007; group 2: P=0.008). Both of these machines were efficient, with similar endothelial cell loss. This endothelial cell loss was related to the increased nuclear sclerosis grade and increased phacoemulsification power.

  10. A structural model for the in vivo human cornea including collagen-swelling interaction

    PubMed Central

    Cheng, Xi; Petsche, Steven J.; Pinsky, Peter M.

    2015-01-01

    A structural model of the in vivo cornea, which accounts for tissue swelling behaviour, for the three-dimensional organization of stromal fibres and for collagen-swelling interaction, is proposed. Modelled as a binary electrolyte gel in thermodynamic equilibrium, the stromal electrostatic free energy is based on the mean-field approximation. To account for active endothelial ionic transport in the in vivo cornea, which modulates osmotic pressure and hydration, stromal mobile ions are shown to satisfy a modified Boltzmann distribution. The elasticity of the stromal collagen network is modelled based on three-dimensional collagen orientation probability distributions for every point in the stroma obtained by synthesizing X-ray diffraction data for azimuthal angle distributions and second harmonic-generated image processing for inclination angle distributions. The model is implemented in a finite-element framework and employed to predict free and confined swelling of stroma in an ionic bath. For the in vivo cornea, the model is used to predict corneal swelling due to increasing intraocular pressure (IOP) and is adapted to model swelling in Fuchs' corneal dystrophy. The biomechanical response of the in vivo cornea to a typical LASIK surgery for myopia is analysed, including tissue fluid pressure and swelling responses. The model provides a new interpretation of the corneal active hydration control (pump-leak) mechanism based on osmotic pressure modulation. The results also illustrate the structural necessity of fibre inclination in stabilizing the corneal refractive surface with respect to changes in tissue hydration and IOP. PMID:26156299

  11. Could adverse effects and complications of selective laser trabeculoplasty be decreased by low-power laser therapy?

    PubMed

    Paiva, Alexandre de Carvalho Mendes; da Fonseca, Adenilson de Souza

    2017-11-30

    Selective laser trabeculoplasty (SLT) has been used for treatment of primary open-angle glaucoma, ocular hypertension, pigmenter and pseudoexfoliative glaucoma being considered a low-risk procedure. Therefore, transitory and permanent adverse effects have been reported, including corneal changes, subclinical edema, and reduction in endothelial cells and in central corneal thickness. Despite rarer, serious corneal complications after SLT can be permanent and lead to visual impairment, central corneal haze, opacity and narrowing. The mechanism involves increase of vasoactive and chemotactic cytokines causing inflammatory infiltrate, destruction of stromal collagen by fibroblasts and increase of matrix metalloproteinases type 2, which impair reepithelization. SLT also increases free radical production and reduces antioxidant enzymes, resulting in endothelium damages. Low-power laser therapy (LPLT) has been used in regenerative medicine based on its biostimulatory and anti-inflammatory effects. Biostimulation occurs through the interaction of laser photons with cytochrome C oxidase enzyme, which activates intracellular biochemical cascades causing synthesis of a number of molecules related to anti-inflammatory, regenerative effects, pain relief and reduction in edema. It has been showed that LPLT reduces gene expression related to pro-inflammatory cytokines and matrix metalloproteinases, and it increases expression of growth factors related to its proliferative and healing actions. Although radiations emitted by low-power lasers are considered safe and able to induce therapeutic effects, researches based on experimental models for glaucoma could bring important data if LPLT could be an alternative approach to improve acceptation for patients undergoing SLT.

  12. Factors affecting DSAEK graft lenticle adhesion: an in vitro experimental study.

    PubMed

    Vaddavalli, Pravin K; Diakonis, Vasilios F; Canto, Ana P; Kankariya, Vardhaman P; Pappuru, Rajeev R; Ruggeri, Marco; Banitt, Michael R; Kymionis, George D; Yoo, Sonia H

    2014-06-01

    The aim of this study was to evaluate different factors that affect Descemet stripping automated endothelial keratoplasty (DSAEK) donor graft lenticle adhesion to the recipient cornea. This experimental study included 10 eye bank recipient corneas and 10 donor DSAEK lenticles. Recipient corneas were mounted on an artificial anterior chamber (AC), whereas donor lenticles were placed beneath the host cornea. Using optical coherence tomography and imaging software, the interface gap (IG) between the donor and recipient cornea was quantified to evaluate the effect of variations in AC air fill pressure, AC air fill duration, corneal massage, and corneal venting incisions on DSAEK donor graft lenticle adhesion. Different intraocular pressures (IOP) under air for the same time intervals, do not significantly correlate with the IG; nevertheless, it was noticed that the IG decreases as the IOP increases. With respect to the magnitude of AC IOP, there was no statistically significant difference when comparing 10 mm Hg with 30 mm Hg and assessing IG (P = 0.4). Complete air-fluid exchange resulted in significantly higher IG when compared with AC air bubble of 10 and 30 mm Hg that was sustained for 1 hour (P < 0.05). Furthermore, corneal surface massage did not facilitate DSAEK graft adhesion (P = 0.59). Finally, paracentral venting incisions followed by interface fluid aspiration seemed to significantly decrease the IG (P = 0.014). Corneal venting incisions and higher AC IOP values seem to facilitate DSAEK donor graft lenticle adhesion to the recipient cornea.

  13. In vitro effects of three blood derivatives on human corneal epithelial cells.

    PubMed

    Freire, Vanesa; Andollo, Noelia; Etxebarria, Jaime; Durán, Juan A; Morales, María-Celia

    2012-08-15

    We compared the effects of three blood derivatives, autologous serum (AS), platelet-rich plasma (PRP), and serum derived from plasma rich in growth factors (PRGF), on a human corneal epithelial (HCE) cell line to evaluate their potential as an effective treatment for corneal epithelial disorders. The concentrations of epidermal growth factor (EGF), fibroblast growth factor (FGF), vascular endothelial growth factor (VEGF), hepatocyte growth factor (HGF), platelet-derived growth factor (PDGF), and fibronectin were quantified by ELISA. The proliferation and viability of HCE cells were measured by an 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) colorimetric assay. Cell morphology was assessed by phase-contrast microscopy. The patterns of expression of several connexin, involucrin, and integrin α6 genes were analyzed by real-time RT-PCR. We found significantly higher levels of EGF in PRGF compared to AS and PRP. However, AS and PRGF induced robust proliferation of HCE cells. In addition, PRGF cultured cells grew as heterogeneous colonies, exhibiting differentiated and non-differentiated cell phenotypes, whereas AS- and PRP-treated cultures exhibited quite homogeneous colonies. Finally, PRGF upregulated the expression of several genes associated with communication and cell differentiation, in comparison to AS or PRP. PRGF promotes biological processes required for corneal epithelialization, such as proliferation and differentiation. Since PRGF effects are similar to those associated with routinely used blood derivatives, the present findings warrant further research on PRGF as a novel alternative treatment for ocular surface diseases.

  14. The absorption characteristics of the human cornea in ultraviolet-a crosslinking.

    PubMed

    Koppen, Carina; Gobin, Laure; Tassignon, Marie-José

    2010-03-01

    With respect to the safety of ultraviolet-A (UVA) crosslinking for the corneal endothelium, an absorption coefficient is used that has been calculated in riboflavin soaked porcine corneas. We aim to validate this value for clinical use by measuring the absorption coefficient for UVA 365 nm in postmortem human corneas after instilling riboflavin on the corneal surface. Corneal thickness was measured in nine pairs of human donor eyes of which one eye was subjected to manual removal of the epithelium, whereas the epithelium of the fellow eye was left intact. Both eyes were instilled with riboflavin 0.1% in dextran 20% on the intact globe. After 20 min, the corneas were rinsed, and a corneoscleral button was trephined. The transmission of the cornea for UVA 365 nm was measured by transillumination, which allows calculation of the absorption coefficient. Measurement of average corneal thickness was 658.5 +/- 51.5 microm when the epithelium was removed, and 758.3 +/- 98.8 microm without epithelial removal. The average transmittance for UVA 365 nm was 12.89 +/- 4.10% with epithelial debridement and 28.52 +/- 4.39% without (P<0.05). The resultant average absorption coefficient is 32 +/- 5 cm when the epithelium is removed and 17 +/- 2 cm when it is left intact (P<0.05). Our results show an absorption coefficient for human corneas that is much lower than the values reported in the literature. This finding may be relevant when considering endothelial safety of the clinical crosslinking treatment.

  15. Comparison of sequential vs same-day simultaneous collagen cross-linking and topography-guided PRK for treatment of keratoconus.

    PubMed

    Kanellopoulos, Anastasios John

    2009-09-01

    The safety and efficacy of corneal collagen cross-linking (CXL) and topography-guided photorefractive keratectomy (PRK) using a different sequence and timing were evaluated in consecutive keratoconus cases. This study included a total of 325 eyes with keratoconus. Eyes were divided into two groups. The first group (n=127 eyes) underwent CXL with subsequent topography-guided PRK performed 6 months later (sequential group) and the second group (n=198 eyes) underwent CXL and PRK in a combined procedure on the same day (simultaneous group). Statistical differences were examined for pre- to postoperative changes in uncorrected (UCVA, logMAR) and best-spectacle-corrected visual acuity (BSCVA, logMAR), manifest refraction spherical equivalent (MRSE), keratometry (K), topography, central corneal thickness, endothelial cell count, corneal haze, and ectatic progression. Mean follow-up was 36+/-18 months (range: 24 to 68 months). At last follow-up in the sequential group, the mean UCVA improved from 0.9+/-0.3 logMAR to 0.49+/-0.25 logMAR, and mean BSCVA from 0.41+/-0.25 logMAR to 0.16+/-0.22 logMAR. Mean reduction in spherical equivalent refraction was 2.50+/-1.20 diopters (D), mean haze score was 1.2+/-0.5, and mean reduction in K was 2.75+/-1.30 D. In the simultaneous group, mean UCVA improved from 0.96+/-0.2 logMAR to 0.3+/-0.2 logMAR, and mean BSCVA from 0.39+/-0.3 logMAR to 0.11+/-0.16 logMAR. Mean reduction in spherical equivalent refraction was 3.20+/-1.40 D, mean haze score was 0.5+/-0.3, and mean reduction in K was 3.50+/-1.3 D. Endothelial cell count preoperatively and at last follow-up was unchanged (P<.05) in both groups. Statistically, the simultaneous group did better (P<.05) in all fields evaluated, with improvement in UCVA and BSCVA, a greater mean reduction in spherical equivalent refraction and keratometry, and less corneal haze. Same-day simultaneous topography-guided PRK and CXL appears to be superior to sequential CXL with later PRK in the visual rehabilitation of progressing keratoconus. Copyright 2009, SLACK Incorporated.

  16. Celastrol nanomicelles attenuate cytokine secretion in macrophages and inhibit macrophage-induced corneal neovascularization in rats.

    PubMed

    Li, Zhanrong; Li, Jingguo; Zhu, Lei; Zhang, Ying; Zhang, Junjie; Yao, Lin; Liang, Dan; Wang, Liya

    The aim of the present study was to investigate the inhibitory effects of celastrol-loaded nanomicelles (CNMs) on activated macrophage-induced corneal neovascularization (CNV) in rats and cytokine secretion in macrophages. Using an angiogenesis assay in vitro, we detected the effects of CNMs on human umbilical vein endothelial cell (HUVEC) migration and invasion. In addition, the expression levels of cytokines secreted from hypoxia-induced macrophages were assessed through cytokine array analysis. The expression of hypoxia-inducible factors-1α (HIF-1α), nuclear factor-kappa B p65 (NF-κB p65), phospho-nuclear factor-kappa B p65 (phospho-NF-κB p65), p38 mitogen-activated protein kinase (p38 MAPK), phospho-p38 MAPK, extracellular signal-regulated kinase 1/2 (ERK1/2), and phospho-ERK1/2 was analyzed by western blotting. Activated macrophages were elicited through mineral oil lumbar injection, labeled with 1,19-dioctadecyl-3-3-39,39-tetramethylindocarbocyanine (DiI) and implanted into the corneal micro-pocket to induce CNV and to assess the antiangiogenic effect in rats. CNV was morphometrically analyzed using ImageJ software. Histopathological features were evaluated by immunofluorescence immunostaining for vascular endothelial growth factor (VEGF) and matrix metalloproteinase-9 (MMP-9) on day 2 after surgery. In the present study, the results indicated that CNMs significantly inhibited the migration and invasion of HUVECs; remarkably attenuated the expression of VEGF, tumor necrosis factor-α, interleukin-1α, monocyte chemoattractant protein 1, cytokine-induced neutrophil chemoattractant 3, and MMP-9 protein; and downregulated ERK1/2, p38 MAPK, NF-κB activation, and HIF-1α expression in macrophages. The peritoneal cells elicited using mineral oil were highly purified macrophages, and the length and area of CNV were significantly decreased in the CNMs group compared with the control group. There was a significant reduction in the expression of VEGF and MMP-9 in activated macrophages and corneal tissue after pretreatment with CNMs in this model. In conclusion, CNMs potently suppressed macrophage-induced CNV via the inhibition of VEGF and MMP-9 expression. This effect might be mediated through attenuating macrophages via HIF-1α, MAPK, and NF-κB signaling pathways.

  17. Ocular Toxicity Secondary to Asclepias physocarpa: The Balloon Plant.

    PubMed

    Pina, Susana; Pedrosa, Catarina; Santos, Cristina; Feijóo, Bernardo; Pego, Peter; Vendrell, Cristina; Santos, Maria João; Prieto, Isabel

    2014-01-01

    We report a case of a 65-year-old woman with symptoms of blurred vision and ocular irritation a few hours after accidental contact of the right eye with Asclepias physocarpa milky latex. Observation showed a diffuse conjunctival hyperemia and stromal corneal edema with Descemet's membrane folds. Recovery was fast and apparently complete in less than one month. However, specular microscopy at 6-months follow-up showed an abnormal endothelial morphology as sequelae, suggesting this condition is not as innocuous as it has been suggested.

  18. [Descemet's stripping automated endothelial keratoplasty (DEAEK). Systematic review of clinical-effectiveness and safety].

    PubMed

    Paz-Valiñas, L; de la Fuente-Cid, R; de Rojas-Silva, M V; López-Rodríguez, I; López-García, M

    2015-04-01

    To conduct a systematic review of the efficacy/effectiveness, safety and cost of Descemet's stripping automated endothelial keratoplasty (DSAEK) technique in patients with corneal endothelial failure. Comprehensive literature search conducted in the main biomedical databases from January-May 2012. Following a critical perusal of the total of 485 abstracts retrieved, 16 case series and one economic evaluation study were included. Corrected distance visual acuity and uncorrected distance visual acuity improved after treatment with DSAEK, attaining values of 0.6 to 0.8 and 0.5 respectively. The degree of post-DSAEK astigmatism was not significant with respect to baseline values. The main complications were graft dislocation-detachment (1.5-23%), primary failure (0-12%) and endothelial rejection (0.8-8.5%). In Fuchs' dystrophy and bullous keratopathy, data on the effectiveness of DSAEK indicate post-intervention improvement in uncorrected and corrected distance visual acuity. Astigmatism arising after DSAEK was not significant. The most significant post-DSAEK complications are linked to the viability of the graft, with the most frequent complications being dislocation-detachment and, to a lesser extent, endothelial rejection. The studies that assess DSAEK are case series, and for the most part retrospective. The quality of this type of studies is both low and limited. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  19. Intracapsular lens extraction for the treatment of pupillary block glaucoma associated with anterior subluxation of the crystalline lens.

    PubMed

    Kim, Yong Joon; Ha, Seung Joo

    2013-01-01

    To report a case of pupillary block glaucoma associated with spontaneous crystalline lens subluxation into the anterior chamber in a 34-year-old man. Dry vitrectomy was performed for securing enough retrolental space, and an intracapsular lens extraction was then performed via a corneolimbal incision. Additional endothelial cell damage was avoided with an injection of viscoelastics and gentle extraction of the crystalline lens. After deepening of the anterior chamber, scleral fixation of the intraocular lens was performed with an ab externo technique. Two months after the operation, a well-fixated intraocular lens was observed and intraocular pressure was stable. The postoperative corneal astigmatism was -3.5 dpt, and the patient had a best-corrected visual acuity of 20/25. Postoperative complications included decreased endothelial cell count and sector iris paralysis near the incision site. An anteriorly subluxated crystalline lens can cause pupillary block glaucoma in healthy young adults. To prevent intraoperative complications, intracapsular lens extraction with dry vitrectomy can be a good surgical option. The endothelial cell density should be closely monitored after surgery.

  20. Single-Pass Microkeratome System for Eye Bank DSAEK Tissue Preparation: Is Stromal Bed Thickness Predictable and Reproducible?

    PubMed

    Choulakian, Mazen Y; Li, Jennifer Y; Ramos, Samuel; Mannis, Mark J

    2016-01-01

    To evaluate the predictability and reproducibility of stromal bed thickness for single-pass donor Descemet stripping automated endothelial keratoplasty (DSAEK) tissue preparation, using the ML7 Microkeratome Donor Cornea System (Med-logics Inc, Athens, TX). In this retrospective chart review of 256 consecutive corneal tissue preparations for DSAEK surgery, from June 2013 to August 2014, tissue thicknesses were divided into 3 groups, depending on surgeon preference: <91 μm (group A), 90 to 120 μm (group B), and 120 to 160 μm (group C). Precut and postcut data were recorded. Average postcut donor corneal thickness was 114 ± 30 μm (range 60-183 μm), whereas the average in group A was 97 ± 23 μm (range 60-128), in group B was 113 ± 21 μm (range 77-179), and in group C was 134 ± 43 (range 89-183). Average postcut endothelial cell density was very adequate at 3013 ± 250 cells per square millimeter. There were a total of 7 failed procedures from 256 attempts, which represents a rate of 2.7%. This rate decreases to 1.5% when analyzing the last 200 cuts. The ML7 Microkeratome Donor Cornea System allows for reliable and reproducible DSAEK tissue preparation. Ultrathin DSAEK tissues can be prepared with a single-pass. Aiming for a graft thickness between 90 and 120 μm seems to be most reliable.

  1. Descemet Membrane Endothelial Keratoplasty for Failed Deep Anterior Lamellar Keratoplasty: A Case Series.

    PubMed

    Einan-Lifshitz, Adi; Sorkin, Nir; Boutin, Tanguy; Mednick, Zale; Kreimei, Mohammad; Chan, Clara C; Rootman, David S

    2018-06-01

    To suggest a new surgical approach for posterior opacities or persistent Descemet membrane (DM) detachment in failed deep anterior lamellar keratoplasty (DALK) and to report the outcome of Descemet membrane endothelial keratoplasty (DMEK) in a series of patients with DALK failure. In this retrospective case series of patients who underwent DMEK for failed DALK at Toronto Western Hospital, 4 patients with failed DALK who underwent DMEK surgery were included. In all 4 cases, big bubble formation during initial DALK surgery had failed and the surgical technique was converted to manual dissection using the Melles technique. In 2 cases, the descemetorhexis in DMEK surgery was performed manually, and in 2 cases, the descemetorhexis was performed with the assistance of the femtosecond laser. Four eyes of 4 patients aged 70 ± 4 years were included. Average follow-up time was 9 ± 5 months. Indications for DALK surgery were corneal dystrophy in 2 patients and corneal scars in the other 2. DALK failure was due to persistent DM detachment that created a double chamber in 2 patients and due to posterior lamellar haze in the other 2. After DMEK surgery, 2 patients had graft detachment and required rebubbling. In 1 patient, the DMEK scroll was attached after 1 rebubble attempt, and in the other patient, a second rebubble attempt was needed. The final visual acuities were 20/40, 20/50, 20/70, and 20/200 (because of dense cataract). All procedures were uneventful. DMEK surgery may be effective in managing DALK failure.

  2. A comparison of patient pain and visual outcome using topical anesthesia versus regional anesthesia during cataract surgery.

    PubMed

    Hosoda, Yoshikatsu; Kuriyama, Shoji; Jingami, Yoko; Hattori, Hidetsugu; Hayashi, Hisako; Matsumoto, Miho

    2016-01-01

    The purpose of this study was to compare the level of patient pain during the phacoemulsification and implantation of foldable intraocular lenses while under topical, intracameral, or sub-Tenon lidocaine. This was a retrospective study. Three hundred and one eyes subjected to cataract surgery were included in this study. All eyes underwent phacoemulsification surgery and intraocular lens implantation using topical, sub-Tenon, or intracameral anesthesia. The topical group received 4% lidocaine drops, and the intracameral group received a 0.1-0.2 cc infusion of 1% preservative-free lidocaine into the anterior chamber through the side port combined with topical drops of lidocaine. The sub-Tenon group received 2% lidocaine. Best-corrected visual acuity, corneal endothelial cell loss, and intraoperative pain level were evaluated. Pain level was assessed on a visual analog scale (range 0-2). There were no significant differences in visual outcome and corneal endothelial cell loss between the three groups. The mean pain score in the sub-Tenon group was significantly lower than that in the topical and intracameral groups (P=0.0009 and P=0.0055, respectively). In 250 eyes without high myopia (< -6D), there were no significant differences in mean pain score between the sub-Tenon and intracameral groups (P=0.1417). No additional anesthesia was required in all groups. Intracameral lidocaine provides sufficient pain suppressive effects in eyes without high myopia, while sub-Tenon anesthesia is better for cataract surgery in eyes with high myopia.

  3. The role of corneal endothelial morphology in graft assessment and prediction of endothelial cell loss during organ culture of human donor corneas.

    PubMed

    Hermel, Martin; Salla, Sabine; Fuest, Matthias; Walter, Peter

    2017-03-01

    Endothelial assessment is crucial in the release of corneas for grafting. We retrospectively analysed the role of endothelial morphology parameters in predicting endothelial cell loss during organ culture. Human donor corneas were cultured in minimal essential medium with 2% fetal calf serum and antibiotics. Initial endothelial morphology was assessed microscopically using score parameters polymegethism (POL), pleomorphism (PLE), granulation (GRA), vacuolization (VAC), segmentation of cell membranes (SEG), Descemet's folds (DF), trypan blue-positive cells (TBPC) and endothelial cell-free areas (ECFA). Some corneas were primarily rejected based on endothelial assessment. Endothelial cell density (ECD) was assessed at the beginning (I-ECD) and end of culture. Corneas were then placed in dehydration medium (as above + 5% dextran 500). In a subgroup, ECD was reassessed after dehydration. Endothelial cell loss during culture (ECL@Culture) and culture+dehydration (ECL-Culture&Dehydration) were calculated. Data were given as mean ± SD and analysed using multiple linear and logistic regression. Odds ratios (OR) and 95% confidence intervals (CI) were calculated. I-ECD was 2812 ± 360/mm 2 (n = 2356). The decision to reject a cornea due to endothelial assessment was associated negatively with I-ECD (OR = 0.77/100 cells, CI 0.7-0.82) and positively with ECFA (OR = 2.7, CI 1.69-4.35), SEG (OR =1.3, CI 1.01-1.68) and donor age (OR = 1.26/decade, CI 1.33-1.41). ECL@Culture was 153 ± 201/mm 2 (n = 1277), ECL@Culture&Dehydration was 169 ± 183/mm 2 (n = 918). ECL@Culture was associated positively with donor age, I-ECD, GRA and TBPC, and negatively with PLE, and DF. ECL@Culture&Dehydration was associated positively with age, sex, initial ECD, POL, PLE, VAC and TBPC. Morphological parameters displayed associations with the exclusion of corneas from culture and with endothelial cell loss. Appropriate parameter selection for screening purposes may help improve graft quality. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Stereo-PIV study of flow inside an eye under cataract surgery

    NASA Astrophysics Data System (ADS)

    Sakakibara, Jun; Yamashita, Masaki; Kobayashi, Tatsuya; Kaji, Yuichi; Oshika, Tetsuro

    2012-04-01

    We measured velocity distributions in the anterior chamber of porcine eyes under simulated cataract surgery using stereoscopic particle image velocimetry (stereo-PIV). The surface of the cornea was detected based on the images of laser-induced fluorescent light emitted from fluorescent dye solution introduced in a posterior chamber. A coaxial phacoemulsification procedure was simulated with standard size (standard coaxial phacoemulsification) and smaller (micro coaxial phacoemulsification) surgical instruments. In both cases, an asymmetric flow rate of irrigation was observed, although both irrigation ports had the same dimensions prior to insertion into the eye. In cases where the tip of the handpiece was placed farther away from the top of the cornea, i.e., closer to the crystalline lens, direct impingement of irrigation flow onto the cornea surface was avoided and the flow turned back toward the handpiece along the surface of the corneal endothelium. Viscous shear stress on the corneal endothelium was computed based on the measured mean velocity distribution. The maximum shear stress for most cases exceeded 0.1 Pa, which is comparable to the shear stress that caused detachment of the corneal endothelial cells reported by Kaji et al. in Cornea 24:S55-S58, (2005). When direct impingement of the irrigation flow was avoided, the shear stress was reduced considerably.

  5. VEGF-A expression by HSV-1–infected cells drives corneal lymphangiogenesis

    PubMed Central

    Wuest, Todd R.

    2010-01-01

    Inflammatory lymphangiogenesis plays a crucial role in the development of inflammation and transplant rejection. The mechanisms of inflammatory lymphangiogenesis during bacterial infection, toll-like receptor ligand administration, and wound healing are well characterized and depend on ligands for the vascular endothelial grow factor receptor (VEGFR) 3 that are produced by infiltrating macrophages. But inflammatory lymphangiogenesis in nonlymphoid tissues during chronic viral infection is unstudied. Herpes simplex virus 1 (HSV-1) infection of the cornea is a leading cause of blindness and depends on aberrant host immune responses to antigen within the normally immunologically privileged cornea. We report that corneal HSV-1 infection drives lymphangiogenesis and that corneal lymphatics persist past the resolution of infection. The mechanism of HSV-1–induced lymphangiogenesis was distinct from the described mechanisms of inflammatory lymphangiogenesis. HSV-1–elicited lymphangiogenesis was strictly dependent on VEGF-A/VEGFR-2 signaling but not on VEGFR-3 ligands. Macrophages played no role in the induction of lymphangiogenesis and were not a detectable source of VEGF-A. Rather, using VEGF-A reporter transgenic mice, we have identified infected epithelial cells as the primary source of VEGF-A during HSV-1 infection. Our results indicate that HSV-1 directly induces vascularization of the cornea through up-regulation of VEGF-A expression. PMID:20026662

  6. [Intraoperative Optical Coherence Tomography (MI-OCT) for the Treatment of Corneal Dystrophies].

    PubMed

    Siebelmann, Sebastian; Matthaei, Mario; Heindl, Ludwig M; Bachmann, Björn O; Cursiefen, Claus

    2018-06-01

    The surgical treatment of corneal dystrophies develops rapidly as the use of lamellar corneal grafting techniques continue. While penetrating keratoplasty was the gold standard for treating a variety of dystrophies a few years ago, the affected layers of the cornea can, nowadays, be selectively replaced or ablated using laser technology. Of particular importance for these methods is optical coherence tomography, which has recently been integrated into surgical microscopes (MI-OCT). Literature overview from PubMed and Google.scholar.de supplemented with own imaging data. The MI-OCT enables the intraoperative real-time monitoring of different ophthalmic surgical procedures, such as deep anterior lamellar keratoplasty, Descemet's membrane endothelial keratoplasty, as well as minimally-invasive procedures, such as phototherapeutic keratectomy. In addition, it enables an evaluation of the cornea, but also of structures of the anterior chamber, in situations in which the cornea, for example, is clouded by an edema. Microscope-integrated, intraoperative optical coherence tomography (MI-OCT) represents a useful supplement to the normal surgical microscope. It is superior to the sole surgical microscope, especially in already severely clouded corneas, and represents a sensible supplement, especially for novel lamellar transplantation procedures. Prospective randomized trials are necessary to increase safety and efficacy when using MI-OCT for different indications. Georg Thieme Verlag KG Stuttgart · New York.

  7. Organ culture storage of pre-prepared corneal donor material for Descemet's membrane endothelial keratoplasty

    PubMed Central

    Bhogal, Maninder; Matter, Karl; Balda, Maria S; Allan, Bruce D

    2016-01-01

    Purpose To evaluate the effect of media composition and storage method on pre-prepared Descemet's membrane endothelial keratoplasty (DMEK) grafts. Methods 50 corneas were used. Endothelial wound healing and proliferation in different media were assessed using a standard injury model. DMEK grafts were stored using three methods: peeling with free scroll storage; partial peeling with storage on the stroma and fluid bubble separation with storage on the stroma. Endothelial cell (EC) phenotype and the extent of endothelial overgrowth were examined. Global cell viability was assessed for storage methods that maintained a normal cell phenotype. Results 1 mm wounds healed within 4 days. Enhanced media did not increase EC proliferation but may have increased EC migration into the wounded area. Grafts that had been trephined showed evidence of EC overgrowth, whereas preservation of a physical barrier in the bubble group prevented this. In grafts stored in enhanced media or reapposed to the stroma after trephination, endothelial migration occurred sooner and cells underwent endothelial-mesenchymal transformation. Ongoing cell loss, with new patterns of cell death, was observed after returning grafts to storage. Grafts stored as free scrolls retained more viable ECs than grafts prepared with the fluid bubble method (74.2± 3% vs 60.3±6%, p=0.04 (n=8). Conclusion Free scroll storage is superior to liquid bubble and partial peeling techniques. Free scrolls only showed overgrowth of ECs after 4 days in organ culture, indicating a viable time window for the clinical use of pre-prepared DMEK donor material using this method. Methods for tissue preparation and storage media developed for whole corneas should not be used in pre-prepared DMEK grafts without prior evaluation. PMID:27543290

  8. Visual acuity, refractive error, and endothelial cell density 6 and 12 months after deep lamellar endothelial keratoplasty.

    PubMed

    Fillmore, Parley D; Sutphin, John E; Goins, Kenneth M

    2010-06-01

    To report the visual acuity, refractive outcome, and endothelial cell density (ECD) up to 1 year after deep lamellar endothelial keratoplasty (DLEK) in a large prospective series. Eighty-six DLEK procedures were performed and evaluated in a prospective interventional case series. Subgroup analysis was performed to compare results from large-incision (9 mm) DLEK (n = 7), small-incision (5-8 mm) DLEK (n = 70), and penetrating keratoplasty (PKP) conversion (n = 9). Outcome measures included best-corrected visual acuity (BCVA), manifest refraction, corneal topographic astigmatism, and ECD. The percentage of eyes that achieved a BCVA of 20/40 or better after DLEK was 55% at 6 months, increasing to 61% at 1 year. Topographic astigmatism and spherical equivalent were not significantly different than preoperative measurements up to 1 year after DLEK (P > 0.05). An endothelial cell loss of 40% at 6 months and 48% by 1 year was observed. The mean ECD after DLEK was 1831 +/- 472 cells per square millimeter at 6 months and 1569 +/- 601 cells per square millimeter at 12 months. When evaluated by incision size, the ECD was better at 2066 +/- 558 cells per square millimeter with a 9-mm incision compared with only 1516 +/- 585 cells per square millimeter with a smaller incision at 1 year, although this did not reach significance (P = 0.075). The endothelial cell loss after penetrating keratoplasty conversion was similar to that in the large-incision group (P > 0.05). DLEK provides good visual acuity (> or =20/40) for the majority of patients at 1 year with stable refractive error compared with baseline. Refractive stability was observed with both large- and small-incision DLEKs; however, worrisome endothelial cell loss was observed, especially with a small-incision technique.

  9. Standardization of the Descemet membrane endothelial keratoplasty technique: Outcomes of the first 450 consecutive cases.

    PubMed

    Satué, M; Rodríguez-Calvo-de-Mora, M; Naveiras, M; Cabrerizo, J; Dapena, I; Melles, G R J

    2015-08-01

    To evaluate the clinical outcome of the first 450 consecutive cases after Descemet membrane endothelial keratoplasty (DMEK), as well as the effect of standardization of the technique. Comparison between 3 groups: Group I: (cases 1-125), as the extended learning curve; Group II: (cases 126-250), transition to technique standardization; Group III: (cases 251-450), surgery with standardized technique. Best corrected visual acuity, endothelial cell density, pachymetry and intra- and postoperative complications were evaluated before, and 1, 3 and 6 months after DMEK. At 6 months after surgery, 79% of eyes reached a best corrected visual acuity of≥0.8 and 43%≥1.0. Mean preoperative endothelial cell density was 2,530±220 cells/mm2 and 1,613±495 at 6 months after surgery. Mean pachymetry measured 668±92 μm and 526±46 μm pre- and (6 months) postoperatively, respectively. There were no significant differences in best corrected visual acuity, endothelial cell density and pachymetry between the 3 groups (P > .05). Graft detachment presented in 17.3% of the eyes. The detachment rate declined from 24% to 12%, and the rate of secondary surgeries from 9.6% to 3.5%, from group I to III respectively. Visual outcomes and endothelial cell density after DMEK are independent of the technique standardization. However, technique standardization may have contributed to a lower graft detachment rate and a relatively low number of secondary interventions required. As such, DMEK may become the first choice of treatment in corneal endothelial disease. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Asymptomatic Infection in Decompensated Full-Thickness Corneal Grafts Referred for Repeat Penetrating Keratoplasty.

    PubMed

    Nahum, Yoav; Leon, Pia; Ricci-Filipovic, Benedetta Azzurra; Camposampiero, Davide; Ponzin, Diego; Busin, Massimo

    2017-04-01

    We report a case series of asymptomatic infections affecting failed corneal grafts in patients referred for repeat penetrating keratoplasty (PK). In this retrospective, noncomparative, interventional case series, we reviewed the medical records of all repeat PK procedures performed at Villa Serena-Villa Igea private Hospitals (Forlì, Italy) between January 2011 and March 2016. Specifically, preoperative and postoperative slit-lamp examinations, and the results of histological and bacteriological examinations, were noted. Fifty-three repeat PKs were performed in the study period. All patients were referred because of long-standing graft decompensation with stromal scars or surface irregularities, thus unsuitable for endothelial keratoplasty. None was referred because of presumed infection. Histological examination of the explanted buttons showed the presence of microorganisms of various types in 7 eyes. Cultures were positive in 4 of these cases and in one additional case Staphylococcus aureus was grown in culture, but was not seen in the histology specimen. None of the patients presented with unusual pain, tearing, or discomfort. Preoperative abnormal clinical findings included epithelial defect (n = 6), focal whitening of corneal stroma (n = 5), crystalline keratopathy (n = 1), and an elevated pigmented lesion (n = 1). After repeat PK, recurrence of the infection was seen in 5 of 7 (71%) cases, 2 of which required a third PK procedure. Apparently quiet eyes with failed PK can harbor slow-growing asymptomatic infection. An epithelial defect in a failed PK graft should raise suspicion of infection. Routine cultures and histological examination of the excised corneal buttons are instrumental in the diagnosis of these infections and can guide further treatment.

  11. Effects of 5% sodium chloride ophthalmic ointment on thickness and morphology of the normal canine cornea.

    PubMed

    Samuel, Michelle; Thomasy, Sara M; Calderon, Allison S; Kass, Philip H; Collins, Keith; Murphy, Christopher J

    2018-06-21

    To determine the effect of 5% sodium chloride ophthalmic ointment (5% NaCl) on thickness and morphology of the normal canine cornea using ultrasonic pachymetry (USP), in vivo confocal microscopy (IVCM), and Fourier-domain optical coherence tomography (FD-OCT). Five healthy laboratory Beagles received ophthalmic examinations including USP, IVCM, and FD-OCT prior to and at fixed intervals following treatment. The right and left eyes were treated with 5% NaCl and artificial tears ophthalmic ointment (AT), respectively, every 2 hours for 4 treatments/d (days 2-9), and then hourly for 7 treatments/d (day 10). Treatment groups were statistically compared using mixed-effects linear regression. Treatment with 5% NaCl resulted in a 12 μm decrease in corneal thickness from baseline (P < .001), while there was no significant difference in corneal thickness between values obtained at baseline and following treatment with AT (P = .82). Epithelial cell density significantly increased from baseline (530 ± 52 cells/mm 2 ) to 577 ± 43 and 567 ± 15 cells/mm 2 with 5% NaCl and AT, respectively (P = .003 and .005, respectively). However, keratocyte cell density in the anterior and posterior stroma and endothelial cell density did not significantly differ following treatment with 5% NaCl or AT ointment (P > .05). Short-term topical treatment with 5% NaCl decreased corneal thickness in normal dogs with no observable changes in corneal morphology or signs of ocular toxicity. © 2018 American College of Veterinary Ophthalmologists.

  12. Effect of intracameral injection of fibrin tissue sealant on the rabbit anterior segment

    PubMed Central

    Chew, Annabel C.Y.; Tan, Donald T.H.; Poh, Rebekah; HM, Htoon; Beuerman, Roger W.

    2010-01-01

    Purpose To investigate the effect of intracameral injection of fibrin tissue sealant on the anterior segment structures in a rabbit model. Methods One eye of 10 rabbits received an intracameral injection of fibrin tissue sealant with a thrombin concentration of 500 IU (TISSEEL), and the fellow eye received an intracameral injection of balanced salt solution as a control. The rabbits were followed up with serial slit-lamp examinations, photography, high resolution anterior segment optical coherence tomography scans with pachymetry measurement, and intraocular pressure (IOP) monitoring until complete dissolution of the fibrin sealant. Corneal endothelial cell viability was evaluated using live/dead cell assays. Apoptosis of the cornea and trabecular meshwork were evaluated using TUNEL assays. Ultra-structural examinations of the cornea and trabecular meshwork were performed using electron microscopy. Histology of the trabecular meshwork and iris were analyzed using light microscopy. Results The quantity of the intracameral fibrin sealant was shown to be significantly correlated with increased IOP and pachymetry post-operatively. Complete dissolution of the fibrin sealant occurred between 15 and 30 days. Live/dead cell assays showed no decrease in viability of the corneal endothelium, and TUNEL assays showed no increase in apoptosis of the corneal epithelium, stroma, endothelium, or trabecular meshwork in the eyes with the fibrin sealant. Light and electron microscopy of the anterior segment structures were unremarkable. Conclusion The intracameral use of fibrin glue was associated with a transient increase in IOP and pachymetry. However, there was no evidence of toxicity or structural damage to the corneal endothelium, trabecular meshwork, or iris. PMID:20596250

  13. Factors associated with corneal graft survival in the cornea donor study.

    PubMed

    Sugar, Alan; Gal, Robin L; Kollman, Craig; Raghinaru, Dan; Dontchev, Mariya; Croasdale, Christopher R; Feder, Robert S; Holland, Edward J; Lass, Jonathan H; Macy, Jonathan I; Mannis, Mark J; Smith, Patricia W; Soukiasian, Sarkis H; Beck, Roy W

    2015-03-01

    The Cornea Donor Study (CDS) showed that donor age is not a factor in survival of most penetrating keratoplasties for endothelial disease. Secondary analyses confirm the importance of surgical indication and presence of glaucoma in outcomes at 10 years. To assess the relationship between donor and recipient factors and corneal graft survival in the CDS. Multicenter prospective, double-masked, controlled clinical trial conducted at 80 clinical sites. One hundred five surgeons enrolled 1090 participants undergoing corneal transplant for a moderate-risk condition, principally Fuchs dystrophy or pseudophakic or aphakic corneal edema (PACE). Forty-three eye banks provided corneas. Corneas from donors younger than 66 years and donors 66 years or older were assigned, masked to donor age. Surgery and postoperative care were performed according to the surgeons' usual routines. Participants were followed up for as long as 12 years. Graft failure, defined as a regrafting procedure or a cloudy cornea for 3 consecutive months. The 10-year cumulative probability of graft failure was higher in participants with PACE than in those with Fuchs dystrophy (37% vs 20%; hazard ratio [HR], 2.1 [99% CI, 1.4-3.0]; P < .001) and in participants with a history of glaucoma before penetrating keratoplasty, particularly with prior glaucoma surgery (58% with prior glaucoma surgery and use of medications to lower intraocular pressure at the time of surgery vs 22% with no history of glaucoma surgery or medication use; HR, 4.1 [99% CI, 2.2-7.5]; P < .001). We found trends toward increased graft failure in recipients who were 70 years or older compared with those younger than 60 years (29% vs 19%; HR, 1.2 [99% CI, 0.7-2.1]; P = .04) or were African American (HR, 1.5; P = .11) or who had a history of smoking (35% vs 24%; HR, 1.6 [99% CI, 0.9-2.8]; P = .02). Lower endothelial cell density (ECD) and higher corneal thickness (CT) at 6 months (6% vs 41% for ECD ≥2700 vs <1700 cells/mm2 [P < .001]; 14% vs 36% for CT <500 vs ≥600 μm [P = .001]), 1 year (4% vs 39% for ECD ≥2700 vs <1700 cells/mm2 [P < .001]; 18% vs 28% for CT <500 vs ≥600 μm [P = .04]), and 5 years (2% vs 29% for ECD ≥1500 vs <500 cells/mm2 [P < .001]; 7% vs 34% for CT <550 vs ≥650 μm [P < .001]) were associated with subsequent graft failure. Most penetrating corneal grafts for Fuchs dystrophy or PACE remain clear at 10 years. The risk for failure is greater for graft recipients with PACE and those with a history of glaucoma. Measurements of ECD and CT during the course of postkeratoplasty follow-up are associated with a risk for failure. However, even with very low ECD and high CT at 5 years, most corneas remain clear at 10 years.

  14. [Original method of extracapsule fragmentation of the lens nucleus during phacoemulsification].

    PubMed

    Avetisov, S E; Iusef, Iusef Naim; Mamikonian, V R; Vvedenskiĭ, A S; Iusef, Said Naim; Mutonen, N V

    2002-01-01

    Clinical estimation of different modifications of phacoemulsification revealed the formation of the second tunnel in the nucleus for its division into quadrants in "four-quadrant phaco" increases the required duration of ultrasonography (US) and irrigation, which causes greater endothelial losses associated with the use of nuclear breakdown by means of a chopper tunnel. When the authors used their own methods of "extracapsular half-nuclei" fragmentation, endothelial losses are rather greater than those with the similar method "stop & "chop", which is associated with closer disposition of the US tip to the posterior corneal surface. At the same time nuclear breakdown by means a chapper in the capsular sac by the "stop & chop" method causes dilation of Zinn's ligaments, fraught by their rupture, particularly if latent derangement or defects of the zonular apparatus, and increases the risk of damage to the posterior capsule by the chopper.

  15. Modulation of corneal wound healing after excimer laser keratomileusis using topical mitomycin C and steroids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talamo, J.H.; Gollamudi, S.; Green, W.R.

    1991-08-01

    A 193-nm excimer laser system was used to create deep stromal ablations in seven New Zealand white rabbits and shallow ablations in three. Eyes were randomized for treatment with topical mitomycin C, steroids, and erythromycin; topical steroids and erythromycin; or topical erythromycin only. All treatment regimens were instituted twice daily for 14 days. All eyes reepithelialized normally within 3 to 5 days. During 10 weeks of follow-up, all eyes developed moderate reticular subepithelial haze without significant differences among treatment groups. Results of light, fluorescence, and electron microscopic examination showed anterior stromal scarring and markedly reduced new subepithelial collagen formation inmore » the group treated with mitomycin C, corticosteroids, and erythromycin. Focal abnormalities of Descemet's membrane and endothelial abnormalities were present in all treatment groups. Combination therapy with topical steroids, mitomycin C, and erythromycin to control the corneal wound healing response after refractive laser surgery appears promising and warrants further study.« less

  16. Wound-Induced Polyploidization: Regulation by Hippo and JNK Signaling and Conservation in Mammals

    PubMed Central

    Losick, Vicki P.; Jun, Albert S.; Spradling, Allan C.

    2016-01-01

    Tissue integrity and homeostasis often rely on the proliferation of stem cells or differentiated cells to replace lost, aged, or damaged cells. Recently, we described an alternative source of cell replacement- the expansion of resident, non-dividing diploid cells by wound-induced polyploidization (WIP). Here we show that the magnitude of WIP is proportional to the extent of cell loss using a new semi-automated assay with single cell resolution. Hippo and JNK signaling regulate WIP; unexpectedly however, JNK signaling through AP-1 limits rather than stimulates the level of Yki activation and polyploidization in the Drosophila epidermis. We found that polyploidization also quantitatively compensates for cell loss in a mammalian tissue, mouse corneal endothelium, where increased cell death occurs with age in a mouse model of Fuchs Endothelial Corneal Dystrophy (FECD). Our results suggest that WIP is an evolutionarily conserved homeostatic mechanism that maintains the size and synthetic capacity of adult tissues. PMID:26958853

  17. Effects of benoxinate hydrochloride 0.4% on the morphological appearance of the cornea using confocal microscopy.

    PubMed

    Perez-Gomez, Inma; Hollingsworth, Jo; Efron, Nathan

    2004-03-01

    To investigate whether benoxinate hydrochloride 0.4% used to make confocal microscopy more comfortable alters the morphology of the cornea as viewed with the confocal microscope. Confocal microscopy was performed on both eyes of 10 subjects prior to instillation of either topical anaesthetic or non-preserved sterile saline, on two randomly ordered occasions. Images of all corneal layers were analysed quantitatively and qualitatively in a masked fashion. The images were similar in appearance in 5/10 subjects, there was greater clarity when anaesthetic was instilled in 4/10 subjects, and in the remaining subject there was greater clarity when saline was used. Anaesthetic had no influence on anterior keratocyte density (AKD), posterior keratocyte density (PKD) or endothelial cell density (ECD). Local anaesthetic does not affect corneal morphology as imaged using the confocal microscope. However, failure to use anaesthetic may lead to a degradation of image quality due to patient discomfort and excessive eye movements.

  18. A Case of Bilateral Descemet's Membrane and Subepithelial Opacity: In vivo Laser Confocal Microscopic Study.

    PubMed

    Hatta, Yukiko; Yokogawa, Hideaki; Kobayashi, Akira; Torisaki, Makoto; Sugiyama, Kazuhisa

    2013-01-01

    To report the in vivo laser confocal microscopy findings from a patient with Descemet's membrane and subepithelial opacity OU. A healthy 41-year-old male with Descemet's membrane and subepithelial opacity OU was studied. Routine ophthalmic examination, standard slit-lamp biomicroscopy, and in vivo laser confocal microscopic analysis of the entire corneal layer were performed. Slit-lamp biomicroscopy revealed subepithelial opacity in the mid-peripheral to peripheral cornea and numerous opacities located at the level of Descemet's membrane. It was difficult to distinguish the precise histological location of the opacity. In vivo laser confocal microscopy showed numerous hyperreflective particles in the subepithelium to superficial stroma and hyperreflectivity of Descemet's membrane. No abnormalities could be detected in the epithelial cell layer, midstromal layer, deep stromal layer, or endothelial cell layer. Although the origin of the corneal opacities was unclear, in vivo laser confocal microscopy was useful for observing microstructural abnormalities in a case of Descemet's membrane and subepithelial opacity.

  19. A Case of Bilateral Descemet's Membrane and Subepithelial Opacity: In vivo Laser Confocal Microscopic Study

    PubMed Central

    Hatta, Yukiko; Yokogawa, Hideaki; Kobayashi, Akira; Torisaki, Makoto; Sugiyama, Kazuhisa

    2013-01-01

    Purpose To report the in vivo laser confocal microscopy findings from a patient with Descemet's membrane and subepithelial opacity OU. Case Report A healthy 41-year-old male with Descemet's membrane and subepithelial opacity OU was studied. Routine ophthalmic examination, standard slit-lamp biomicroscopy, and in vivo laser confocal microscopic analysis of the entire corneal layer were performed. Slit-lamp biomicroscopy revealed subepithelial opacity in the mid-peripheral to peripheral cornea and numerous opacities located at the level of Descemet's membrane. It was difficult to distinguish the precise histological location of the opacity. In vivo laser confocal microscopy showed numerous hyperreflective particles in the subepithelium to superficial stroma and hyperreflectivity of Descemet's membrane. No abnormalities could be detected in the epithelial cell layer, midstromal layer, deep stromal layer, or endothelial cell layer. Conclusion Although the origin of the corneal opacities was unclear, in vivo laser confocal microscopy was useful for observing microstructural abnormalities in a case of Descemet's membrane and subepithelial opacity. PMID:23626574

  20. Spontaneous dislocation of a crystalline lens to the anterior chamber with pupillary block glaucoma in Noonan Syndrome: a case report.

    PubMed

    Mukhopadhyaya, Udayaditya; Chakraborti, Chandana; Mondal, Anindita; Pattyanayak, Ujjal; Agarwal, Rajesh Kumar; Tripathi, Partha

    2014-01-01

    We report a 13-year-old child with Noonan Syndrome who developed spontaneous dislocation of the crystalline lens in anterior chamber leading to pupillary block glaucoma in the left eye and subluxation of lens in right eye. Intracapsular extraction of the dislocated lens was done in the left eye. Prompt diagnosis and management is needed in such cases to avoid glaucoma and corneal endothelial cell damage. We could not find any such case after thorough Medline search.

  1. Ocular Toxicity Secondary to Asclepias physocarpa: The Balloon Plant

    PubMed Central

    Pina, Susana; Pedrosa, Catarina; Santos, Cristina; Feijóo, Bernardo; Pego, Peter; Vendrell, Cristina; Santos, Maria João; Prieto, Isabel

    2014-01-01

    We report a case of a 65-year-old woman with symptoms of blurred vision and ocular irritation a few hours after accidental contact of the right eye with Asclepias physocarpa milky latex. Observation showed a diffuse conjunctival hyperemia and stromal corneal edema with Descemet's membrane folds. Recovery was fast and apparently complete in less than one month. However, specular microscopy at 6-months follow-up showed an abnormal endothelial morphology as sequelae, suggesting this condition is not as innocuous as it has been suggested. PMID:25105044

  2. Effects of experimental exposure to triethylamine on vision and the eye

    PubMed Central

    Jarvinen, P.; Engstrom, K.; Riihimaki, V.; Ruusuvaara, P.; Setala, K.

    1999-01-01

    OBJECTIVES: To determine the effect of triethylamine (TEA) on the cornea and to evaluate the cause of blurred vision. To find the lowest observed effect concentration of exposure to TEA. METHODS: Four people were exposed to TEA for 4 hours at concentrations of 40.6, 6.5, and 3.0 mg/m3. Before and after every exposure, symptoms and ocular microscopy findings were recorded. Binocular visual acuity and contrast sensitivity at 2.5% contrast were also measured. Also, before and after the 40.6 mg/m3 exposure, corneal thickness was measured and ocular dimensions were recorded by ultrasonography, endothelial cells of the cornea were analysed, and serum and lacrimal specimens were collected for the analysis of TEA. RESULTS: After exposure to 40.6 mg/m3 TEA there was a marked oedema in the corneal epithelium and subepithelial microcysts. However, corneal thickness increased only minimally because of the epithelial oedema. The lacrimal concentrations of TEA were, on average (range) 41 (18-83) times higher than the serum TEA concentrations. The vision was blurred in all subjects and visual acuity and contrast sensitivity had decreased in three of the four subjects. After exposure to TEA at 6.5 mg/m3 two subjects experienced symptoms, and contrast sensitivity had decreased in three of the four subjects. There were no symptoms or decreases in contrast sensitivity after exposure to a TEA concentration of 3.0 mg/m3. CONCLUSIONS: TEA caused a marked oedema and microcysts in corneal epithelium but only minor increases in corneal thickness. The effects may be mediated by the lacrimal fluid owing to its high TEA concentration. Four hour exposure to a TEA concentration of 3.0 mg/m3 seemed to cause no effects, whereas exposure to 6.5 mg/m3 for the same period caused blurred vision and a decrease in contrast sensitivity.   PMID:10341738

  3. Corneal endothelial cell loss and corneal biomechanical characteristics after two-step sequential or combined phaco-vitrectomy surgery for idiopathic epiretinal membrane.

    PubMed

    Hamoudi, Hassan; Christensen, Ulrik Correll; La Cour, Morten

    2017-08-01

    To assess the impact of sequential and combined surgery [cataract surgery and 23-gauge pars plana vitrectomy (PPV) with peeling] on corneal endothelium cell density (CED) and corneal biomechanical characteristics. Phakic eyes with epiretinal membrane (ERM) were prospectively allocated to (i) cataract surgery and subsequent PPV (CAT group), (ii) PPV and subsequent cataract surgery (VIT group) or (iii) phacovitrectomy (COMBI group). Eyes were examined at baseline, 1 month after each surgery, and at 3 and 12 months follow-up. Corneal endothelium cell density (CED) was assessed with non-contact specular microscopy. Pachymetry [central cornea thickness (CCT)], keratometry and cornea volume (CV) were measured with Pentacam Scheimpflug camera. Primary outcome was change in CED after 12 months; secondary outcomes were changes in CCT and CV after 12 months. Sixty-two eyes were enrolled and allocated to the three groups. The mean preoperative CED was 2776, 2794 and 2653 cells/mm 2, which decreased significantly at 12 months by 15.3, 20.0 and 19.3% in the CAT, VIT and COMBI group. There was no significant difference in percentage cell loss between the groups at final follow-up. The CED decreased significantly after cataract surgery, but was unaffected by PPV. Central cornea thickness (CCT) increased by 10 μm (p = 0.005) and CV by 1.38 mm 3 (2.3%, p < 0.001) in the COMBI group. There were no significant differences in CCT or CV between the groups at final follow-up. Combined and sequential surgery in ERM leads to a small decrease in CED. Performing cataract surgery before, after or in combination with vitrectomy did not make any significant difference with respect to final CED, CCT or CV. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Corneal epithelial and aqueous humor acidification during in vivo contact lens wear in rabbits.

    PubMed

    Giasson, C; Bonanno, J A

    1994-03-01

    Based on contact lens-induced stromal acidification of the cornea, it has been suggested that the corneal epithelial and endothelial cells also become acidotic during contact lens wear. This alleged acidification may have a role in altered cell appearance and metabolism during contact lens wear. This study investigated the effects of anoxia, carbon dioxide retention, and contact lens gas transmissibility on the epithelial and aqueous humor pH in living rabbits. Epithelial intracellular pH (pHi) and aqueous humor pH were fluorophotometrically measured with a pH sensitive-dye (BCECF) during contact lens wear or exposure to various gas mixtures. Polymethylmethacrylate (PMMA) lens wear acidified epithelial cells by preventing CO2 efflux and by inducing hypoxia. Increasing lens oxygen transmissibility decreased epithelial acidification. After initiation of rigid, gas-permeable (RGP) lens wear or CO2-air exposure, pHi dropped transiently and then recovered partially. This recovery of pHi was not observed during anoxia, whether induced by PMMA lens wear or exposure to 100% N2. The aqueous humor also acidified during PMMA lens wear, a phenomenon not observed during RGP lens wear. Changes in aqueous pH were smaller, slower, and delayed when compared to their epithelial counterparts. Hypoxic contact lens wear acidifies the corneal epithelium and aqueous humor. The aqueous humor pH change indicates a probable endothelial acidification during hypoxic contact lens wear; the pH changes are caused by two separate and additive effects, CO2 retention and hypoxic acidosis. Increases in the oxygen transmissibility of the lens decrease the cellular acidosis, which might minimize cellular complications arising from contact lens wear. We estimate that a lens with an oxygen transmissibility (Dk/L) of 300 x 10(-11) (cm/sec)(ml O2/ml x mm Hg) is needed to prevent epithelial pHi changes in the open eye. In contrast, lenses with Dk/L as low as 18 x 10(-9) (cm/sec)(ml O2/ml x mm Hg) can prevent aqueous humor pH changes.

  5. The use of postoperative slit-lamp optical coherence tomography to predict primary failure in descemet stripping automated endothelial keratoplasty.

    PubMed

    Shih, Carolyn Y; Ritterband, David C; Palmiero, Pat-Michael; Seedor, John A; Papachristou, George; Harizman, Noga; Liebmann, Jeffrey M; Ritch, Robert

    2009-05-01

    To determine if central donor lenticle thickness as measured by slit-lamp optical coherence tomography (SL OCT; Heidelberg Engineering, Heidelberg, Germany) is predictive of primary donor failure in patients undergoing Descemet stripping automated endothelial keratoplasty (DSAEK). Retrospective cross-sectional study. Eighty-four patients who underwent DSAEK surgery by 2 surgeons (D.C.R. and J.A.S.) were enrolled. At each postoperative visit (postoperative day 1, week 1, month 1, and month 2), an SL OCT scan was obtained. Statistical differences in SL OCT measurements of successful and failed DSAEK procedures were measured using the Student t test. A successful DSAEK surgery was defined as having an anatomically attached, clear recipient corneal stroma and donor lenticle compatible with good vision 2 months after surgery. A failed DSAEK surgery was defined as an attached donor lenticle with SL evidence of corneal edema and thickening visible at 2 months or more. Ninety-three eyes of 84 consecutive patients who underwent DSAEK surgery also underwent postoperative SL OCT. After 2 months of follow-up, 82 (88%) procedures were successful and 11 (12%) procedures were failures. The average donor lenticle thickness in successful DSAEK eyes was 314 +/- 128 microm on postoperative day 1 as compared with failed DSAEK eyes, which averaged 532 +/- 259 microm (P = .0013). This was independent regardless of whether the lenticle was attached on the first postoperative visit. Seventy-nine (98%) successful DSAEK eyes had a lenticle thickness of < or = 350 microm at the 1-week visit. All of the failed DSAEK eyes (11 eyes) had a lenticle thickness > or = 350 microm at the 1-week postoperative visit. Statistically significant differences in SL OCT thickness measurements were seen between successful and failed DSAEK cases at all examinations after postoperative week 1. Corneal thickness measurements made with SL OCT are an important predictor of DSAEK failure in both attached and detached lenticles within the first week of surgery. DSAEK lenticle thickness of 350 microm or less at 1 week had a predictability of success of more than 98%.

  6. Assessment of central corneal thickness and corneal endothelial morphology using ultrasound pachymetry, non-contact specular microscopy, and Confoscan 4 confocal microscopy

    PubMed Central

    2013-01-01

    Background The aim was to compare the repeatability, reproducibility and inherent precision of ultrasound pachymetry (USP), noncontact specular microscopy (SP-2000P) and the Confoscan 4 confocal microscope (z-ring CS4) in measuring endothelial cell density (ECD), coefficient of variation of cell size (CV), and central corneal thickness (CCT) in normal eyes. Methods In this prospective study, one eye was selected from each of 30 subjects for the measurements of ECD, CV and CCT, which were taken by two observers. Results were analyzed statistically by repeated-measures analysis of variance (ANOVA) for intra-observer repeatability, inter-observer reproducibility, unpaired t-test, paired t-test, and Bland–Altman analyses to determine limits of agreement (LOA) between the three instruments. Results Mean ECD, measured by SP-2000P and z-ring CS4, were 3115.50 ± 279.70 cells/mm2 and 3167.50 ± 264.75 cells/mm2, respectively (observer 1), and 3192.63 ± 249.42 cells/mm2 (z-ring, observer 2). Mean CV measurements were 27.12 ± 2.51 and 27.10 ± 2.41 (SP-2000P and z-ring CS4, respectively; observer 1), and 27.17 ± 2.25 (z-ring, observer 2). Mean CCT values were 555.11 ± 35.83 μm (USP), 535.82 ± 41.10 μm (SP-2000P) and 552.57 ± 36.83 μm (z-ring CS4), and 554.97 ± 36.34 μm (z-ring CS4, observer 2). However, pairwise tests in all cases there was good repeatability and reproducibility as shown by inter-observer and intra-observer analysis of variance for each of the instruments. Conclusions The SP-2000P and the z-ring CS4 can be used interchangeably to measure ECD and CV. For CCT, the sample size was too small to test for differences of the CCT measurements between the three instruments. PMID:24274022

  7. Modulation of matrix metalloproteinase activity by EDTA prevents posterior capsular opacification

    PubMed Central

    Guha, Rajdeep; Jongkey, Geram; Palui, Himangshu; Mishra, Akhilesh; Vemuganti, Geeta K.; Basak, Samar K.; Mandal, Tapan Kumar; Konar, Aditya

    2012-01-01

    Purpose To evaluate the effect of ethylenediaminetetraacetic acid (EDTA) on posterior capsular opacification (PCO) of rabbits and to assess its effect on intraocular tissues. Methods Modulation of matrix metalloproteinase (MMP) activity in the aqueous following cataract surgery in rabbits and its prevention by different doses of EDTA was determined by zymography. For evaluation of PCO, lensectomized rabbits were intracamerally injected with single dose of either 5 mg EDTA or normal saline. After one month, the degree of PCO was determined by slitlamp biomicroscopy, Miyake-Apple view, and histology of the lens capsule. The effect of EDTA on intra ocular pressure (IOP), corneal endothelial cells, and the retina was evaluated by tonometry, specular microscopy and scanning electron microscopy, and electroretinography. The concentration of EDTA in the aqueous was determined by high performance liquid chromatography (HPLC) at different time points. Results The MMP activity was significantly increased in the aqueous of the operated eyes, and EDTA reduced the degree of increase in a dose-dependent manner. EDTA treatment significantly reduced the degree of PCO (p<0.05). Histopathology of the lens capsule showed a reduction in the number of proliferating and migrating cells as well as MMP2 expression in the EDTA-treated eyes. EDTA treatment did not change the IOP; density, morphology and ultrastructure of the corneal endothelial cells; and electroretinography (ERG). EDTA was detectable in the aqueous humor up to 72 h following a single intracameral injection. Conclusions EDTA reduces the degree of PCO by suppressing the MMP activity and it is not toxic to intra ocular structures at the concentration used. PMID:22815623

  8. COMPARISON OF PROLIFERATIVE CAPACITY OF GENETICALLY-ENGINEERED PIG AND HUMAN CORNEAL ENDOTHELIAL CELLS

    PubMed Central

    Fujita, Minoru; Mehra, Ruhina; Lee, Seung Eun; Roh, Danny S.; Long, Cassandra; Funderburgh, James L.; Ayares, David L.; Cooper, David K. C.; Hara, Hidetaka

    2013-01-01

    Purpose The possibility of providing cultured corneal endothelial cells (CECs) for clinical transplantation has gained much attention. However, the worldwide need for human (h) donor corneas far exceeds supply. The pig (p) might provide an alternative source. The aim of this study was to compare the proliferative capacity of CECs from wild-type (WT) pigs, genetically-engineered (GE) pigs, and humans. Methods The following CECs were cultured – hCECs from donors (i) ≤36 years (young), (ii) ≥49 years (old), and WT pCECs from (iii) neonatal (<5 days), (iv) young (<2 months), and (v) old (>20 months) pigs, and CECs from young (vi) GE pigs (GTKO/CD46 and GTKO/CD46/CD55). Proliferative capacity of CECs was assessed by direct cell counting over 15 days of culture and by BrdU assay. Cell viability during culture was assessed by annexin V staining. The MTT assay assessed cell metabolic activity. Results There was significantly lower proliferative capacity of old CECs than of young CECs (p<0.01) in both pigs and humans. There was no significant difference in proliferative capacity/metabolic activity between young pCECs and young hCECs. However, there was a significantly higher percentage of cell death in hCECs compared to pCECs during culture (p<0.01). Young GE pCECs showed similar proliferative capacity/cell viability/metabolic activity to young WT pCECs. Conclusions Because of the greater availability of young pigs and the excellent proliferative capacity of cultured GE pCECs, GE pigs could provide a source of CECs for clinical transplantation. PMID:23258190

  9. Corneal endothelial cell density and morphology in normal Filipino eyes.

    PubMed

    Padilla, Ma Dominga B; Sibayan, Santiago Antonio B; Gonzales, Clarissa S A

    2004-03-01

    To describe the corneal endothelial cell density and morphology in normal adult Filipino eyes. Specular microscopy was performed in 640 eyes of 320 normal Filipino volunteers aged 20 to 86 years. Of these, 163 were male, and 157 were female. Mean cell density (MCD), mean cell area (MCA), coefficient of variation (CV) in cell size (polymegathism), and hexagonality were recorded and analyzed in relation to fellow eyes, gender, and age. MCD was 2798 +/- 307.2 cells/mm, and MCA was 363.0 +/- 40.3 microm. Results showed that women had a MCD 7.8% greater than men (P < 0.01). Regression analysis showed a consistent decrease in MCD (r = -0.47) and increase in MCA (r = 0.45) from 20 to 60 years of age. This was followed by a marked decrease in correlation and apparent trend reversal for both variables in the groups above 60 years (MCD r = 0.18, MCA r = -0.04) accompanied by a marked increase in CV in cell size (20-60 years r = -0.04, >60 years r = 0.33). A very low negative correlation (r = -0.10) was noted between hexagonality and increasing age through all age groups. The first normative data for the endothelium of Filipino eyes are reported. There are statistically significant differences in MCD between genders, and a consistent decrease in MCD and increase in MCA with age only until 60 years old, after which correlation between age and these variables decreases. Polymegathism and correlation between CV in cell size and age markedly increase after age 60.

  10. Long-term cultivation of human corneal endothelial cells by telomerase expression.

    PubMed

    Liu, Zhiping; Zhuang, Jing; Li, Chaoyang; Wan, Pengxia; Li, Naiyang; Zhou, Qiang; Zhou, Chenjing; Huang, Zheqian; Wang, Zhichong

    2012-07-01

    The objective of this study was to explore the potential role of human telomerase reverse transcriptase (TERT) in extending the proliferative lifespan of human corneal endothelial cells (HCECs) under long-term cultivation. A primary culture was initiated with a pure population of HCECs in DMEM/F12 media containing 10% fetal bovine serum and other various supplements. TERT gene was successfully transfected into normal HCECs. A stable HCECs cell line (TERT-HCECs) that expressed TERT was established. The cells could be subcultured for 36 passages. Within this line of cells, TERT not only extended proliferative lifespan and inhibited apoptosis but also enhanced the cell line remaining the normal characteristics similar to HCECs. There were no significantly differences in the expression of the pump function related proteins voltage dependent anion channel 3 (VDAC3), sodium bicarbonate cotransporter member 4 (SLC4A4), chloride channel protein 3 (CLCN3), Na(+)/K(+)-ATPase α1, and ZO-1 in the cell line TERT-HCECs and primary HCECs. TERT-HCECs formed a monolayer cell sheet, maintained similar cell junction formation and pump function with primary HCECs. Karyotype analysis exhibited normal chromosomal numbers. The soft agar colony assay and tumor formation in nude mice assay showed no malignant alterations in TERT-HCECs. Our findings indicated that we had established a cell line with its similar phenotype and properties to primary HCECs. Further study of the TERT-HCECs may be valuable in studying the function of the cells in vivo. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

    PubMed

    Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L

    2017-08-07

    To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.

  12. Photorefractive keratectomy with a small spot laser and tracker.

    PubMed

    Pallikaris, I G; Koufala, K I; Siganos, D S; Papadaki, T G; Katsanevaki, V J; Tourtsan, V; McDonald, M B

    1999-01-01

    The Autonomous Technologies LADARVision excimer laser system utilizes an eye tracking mechanism and a small spot for photorefractive keratectomy. One hundred and two eyes of 102 patients were treated for -1.50 to -6.25 D of spherical myopia at the spectacle plane using a 6-mm diameter ablation zone. One year follow-up was available for 93 eyes (91%). Uncorrected visual acuity for eyes treated for distance vision was 20/40 or better in 99% (n = 90), and 20/20 or better in 70% (n = 64) of eyes at 12 months. Spectacle-corrected visual acuity was 20/25 or better in all 92 eyes reported; no eye lost more than 2 lines of spectacle-corrected visual acuity, and only 1 eye (1.0%) experienced a loss of 2 lines (20/12.5 to 20/20) at 1 year. The refractive result was within +/- 0.50 D of the desired correction in 75% (n = 70), and within +/- 1.00 D in 93% (n = 86) of eyes at 12 months. Refractive stability was achieved between 3 and 6 months. Corneal haze was graded as trace or less in 100% of the 93 eyes. No significant reductions were noted in contrast sensitivity or endothelial cell density. Patients treated with the Autonomous Technologies LADARVision excimer laser system for -1.50 to -6.25 D of spherical myopia with 1 year follow-up had uncorrected visual acuity of 20/20 or better in 70%, no significant loss of spectacle-corrected visual acuity, no reduction of endothelial cell density or contrast sensitivity, and low levels of corneal haze.

  13. Epoxyeicosanoids promote organ and tissue regeneration.

    PubMed

    Panigrahy, Dipak; Kalish, Brian T; Huang, Sui; Bielenberg, Diane R; Le, Hau D; Yang, Jun; Edin, Matthew L; Lee, Craig R; Benny, Ofra; Mudge, Dayna K; Butterfield, Catherine E; Mammoto, Akiko; Mammoto, Tadanori; Inceoglu, Bora; Jenkins, Roger L; Simpson, Mary A; Akino, Tomoshige; Lih, Fred B; Tomer, Kenneth B; Ingber, Donald E; Hammock, Bruce D; Falck, John R; Manthati, Vijaya L; Kaipainen, Arja; D'Amore, Patricia A; Puder, Mark; Zeldin, Darryl C; Kieran, Mark W

    2013-08-13

    Epoxyeicosatrienoic acids (EETs), lipid mediators produced by cytochrome P450 epoxygenases, regulate inflammation, angiogenesis, and vascular tone. Despite pleiotropic effects on cells, the role of these epoxyeicosanoids in normal organ and tissue regeneration remains unknown. EETs are produced predominantly in the endothelium. Normal organ and tissue regeneration require an active paracrine role of the microvascular endothelium, which in turn depends on angiogenic growth factors. Thus, we hypothesize that endothelial cells stimulate organ and tissue regeneration via production of bioactive EETs. To determine whether endothelial-derived EETs affect physiologic tissue growth in vivo, we used genetic and pharmacological tools to manipulate endogenous EET levels. We show that endothelial-derived EETs play a critical role in accelerating tissue growth in vivo, including liver regeneration, kidney compensatory growth, lung compensatory growth, wound healing, corneal neovascularization, and retinal vascularization. Administration of synthetic EETs recapitulated these results, whereas lowering EET levels, either genetically or pharmacologically, delayed tissue regeneration, demonstrating that pharmacological modulation of EETs can affect normal organ and tissue growth. We also show that soluble epoxide hydrolase inhibitors, which elevate endogenous EET levels, promote liver and lung regeneration. Thus, our observations indicate a central role for EETs in organ and tissue regeneration and their contribution to tissue homeostasis.

  14. An "All-laser" Endothelial Transplant.

    PubMed

    Rossi, Francesca; Canovetti, Annalisa; Malandrini, Alex; Lenzetti, Ivo; Pini, Roberto; Menabuoni, Luca

    2015-07-06

    The "all laser" assisted endothelial keratoplasty is a procedure that is performed with a femtosecond laser used to cut the donor tissue at an intended depth, and a near infrared diode laser to weld the corneal tissue. The proposed technique enables to reach the three main goals in endothelial keratoplasty: a precise control in the thickness of the donor tissue; its easy insertion in the recipient bed and a reduced risk of donor lenticule dislocation. The donor cornea thickness is measured in the surgery room with optical coherence tomography (OCT), in order to correctly design the donor tissue dimensions. A femtosecond laser is used to cut the donor cornea. The recipient eye is prepared by manual stripping of the descemetic membrane. The donor endothelium is inserted into a Busin-injector, the peripheral inner side is stained with a proper chromophore (a water solution of Indocyanine Green) and then it is pulled in the anterior chamber. The transplanted tissue is placed in the final and correct location and then diode laser welding is induced from outside the eyeball. The procedure has been performed on more than 15 patients evidencing an improvement in surgery performances, with a good recovery of visual acuity and a reduced donor lenticule dislocation event.

  15. 5-Fluorouracil for epithelial downgrowth after Descemet stripping automated endothelial keratoplasty.

    PubMed

    Wong, Ryan K; Greene, Daniel P; Shield, David R; Eberhart, Charles G; Huang, John J; Shayegani, Aryan

    2013-12-01

    To report the use of intracameral 5-fluorouracil (5-FU) to treat epithelial downgrowth after performing a Descemet-stripping automated endothelial keratoplasty (DSAEK). We describe the case of a 79-year-old woman who underwent a DSAEK for pseudophakic Fuchs endothelial corneal dystrophy. The patient required 2 repeat DSAEKs for graft failure and persistent, visually significant interface haze. Six months after the third and most recent DSAEK, the patient was followed up and found to have a visual acuity of 20/100. On examination, the patient continued to have a persistent interface haze. However, the patient also had a cellular anterior chamber reaction despite the administration of frequent topical corticosteroids, and subtle findings of a translucent, membranous growth over the iris. Argon laser photocoagulation of the area resulted in a whitening response, characteristic of epithelial growth. Epithelial downgrowth was diagnosed, and intracameral 5-FU was administered. One month after the injection was given, the patient's examination results and vision improved to 20/60. Six months after the single injection, the patient had a clear DSAEK graft without interface haze, a quiet chamber, and 20/30 visual acuity. Epithelial downgrowth that occurs after performing a DSAEK can be treated successfully using intracameral 5-FU.

  16. Corneal Structural Changes in Nonneoplastic and Neoplastic Monoclonal Gammopathies.

    PubMed

    Aragona, Pasquale; Allegra, Alessandro; Postorino, Elisa Imelde; Rania, Laura; Innao, Vanessa; Wylegala, Edward; Nowinska, Anna; Ieni, Antonio; Pisani, Antonina; Musolino, Caterina; Puzzolo, Domenico; Micali, Antonio

    2016-05-01

    To investigate corneal confocal microscopic changes in nonneoplastic and neoplastic monoclonal gammopathies. Three groups of subjects were considered: group 1, twenty normal subjects; group 2, fifteen patients with monoclonal gammopathy of undetermined significance (MGUS); group 3, eight patients with smoldering multiple myeloma and eight patients with untreated multiple myeloma. After hematologic diagnosis, patients underwent ophthalmologic exam and in vivo confocal microscopic study. The statistical analysis was performed using ANOVA and Student-Newman-Keuls tests and receiver operating characteristic (ROC) curve analysis. Epithelial cells of gammopathic patients showed significantly higher reflectivity than controls, demonstrated by optical density (P < 0.001). Subbasal nerve density, branching, and beading were significantly altered in gammopathic patients (P = 0.01, P = 0.02, P = 0.02, respectively). The number of keratocytes was significantly reduced in neoplastic patients (P < 0.001 versus both normal and MGUS) in the anterior, medium, and posterior stroma. The ROC curve analysis showed good sensitivity and specificity for this parameter. Group 2 and 3 keratocytes showed higher nuclear and cytoplasmatic reflectivity in the medium and posterior stroma. Endothelial cells were not affected. Patients with neoplastic gammopathies showed peculiar alterations of the keratocyte number, which appeared significantly reduced. A follow-up with corneal confocal microscopy of patients with MGUS is suggested as a useful tool to identify peripheral tissue alterations linked to possible neoplastic disease development.

  17. The effects of sperminated pullulans on cornea permeability to puerarin and the toxicity.

    PubMed

    Yu, Nannan; Dong, Guo; Ge, Hongyan; Jin, Di; Cui, Hao; Liu, Ping

    2012-10-01

    To investigate the varied effects of sperminated pullulans (SP) with different amino residues on cornea permeability and its local toxicity. Three groups of rabbits were used: control, low-amino residue content SP (SP-L), and high-amino residue content SP (SP-H). The in vitro and in vivo spreading assays were combined with high performance liquid chromatography (HPLC) to measure the concentration of puerarin in the external medium or aqueous humor when 0% SP, 0.2% SP-L, and 0.2% SP-H were included. The toxicity of SP was determined by corneal hydration values, Draize score, aqueous humor protein concentration, corneal endothelial evaluation, as well as light microscopy and electron microscopy. The application of 0.2% SP-L and 0.2% SP-H to the cornea in vitro increased puerarin apparent permeability coefficient by 1.96-fold (P<0.05) and 2.95-fold (P<0.01), respectively. SP-H showed stronger effect than SP-L (P<0.05). For the in vivo assay, those were 1.81-fold (P<0.05) and 3.71-fold (P<0.01), respectively. With the SP application, the corneal hydration values were <83% and Draize scores were <4, with no apparent changes in histological observations. SP is one potential adjuvant promoting puerarin permeability to the cornea, and the high-content amino residue SP showed stronger effect, without ocular toxicity.

  18. Cornea lymphatics drive the CD8+ T-cell response to herpes simplex virus-1.

    PubMed

    Gurung, Hem R; Carr, Meghan M; Carr, Daniel J J

    2017-01-01

    Herpes simplex virus-1 (HSV-1) infection of the cornea induces vascular endothelial growth factor A (VEGF-A)-dependent lymphangiogenesis. However, the extent to which HSV-1-induced corneal lymphangiogenesis impacts the adaptive immune response has not been characterized. Here, we used floxed VEGF-A mice to study the importance of newly created corneal lymphatic vessels in the host adaptive immune response to infection. Whereas the mice infected with the parental virus (strain SC16) exhibited robust corneal lymphangiogenesis, mice that received the recombinant virus (SC16 ICP0-Cre) that expresses Cre recombinase under the control of infected cell protein 0 (ICP0), an HSV-1 immediate-early gene, showed a significant reduction in lymphangiogenesis. There was no difference in virus recovered from the cornea of mice infected with SC16 vs SC16 ICP0-Cre. However, viral loads were significantly elevated in the trigeminal ganglia (TG) of mice with reduced corneal lymphangiogenesis. The increase in viral titer correlated with a significant loss of HSV-1-specific CD8 + T cells that traffic to the TG of mice infected with the recombinant virus. Intrastromal delivery of size-exclusion dye (fluorescein isothiocyanate-dextran) revealed a time-dependent defect in the ability of the lymphatic vessels in SC16 ICP0-Cre-infected mice to transport soluble antigen from the cornea to the draining lymph nodes. We interpret these results to suggest that the newly created lymphatic vessels in the cornea driven by HSV-1 infection are critical in the delivery of soluble viral antigen to the draining lymph node and subsequent development of the CD8 + T-cell response to HSV-1.

  19. Surgical outcome of deep anterior lamellar keratoplasty with air-assisted manual dissection for corneas with previous inflammation or fibrosis

    PubMed Central

    Ho, Yi-Ju; Wu, Cheng-Hsiu; Chen, Hung-Chi; Hsiao, Chin-Shi; Hsueh, Yi-Jen; Ma, David Hui-Kang

    2017-01-01

    PURPOSE: To report our experience in air-assisted manual dissection deep anterior lamellar keratoplasty (DALK) for the treatment of corneal scar with previous inflammation and fibrosis. MATERIALS AND METHODS: We retrospectively reviewed the medical history of 21 patients (male:female = 13:8 mean age 41.9 years old) with corneal pathology from previous infection and inflammation. Trephination diameter ranged from 7.0 to 8.0 mm, and the graft was oversized by 0.25–0.50 mm. Debulking technique was performed to expose Descemet's membrane after filling stroma with air. Starting from postoperative 3 months, selective suture removal was performed to reduce corneal astigmatism. RESULTS: The mean follow-up period was 59.9 ± 19.8 (20–96) months. Intraoperative microperforation occurred in 2 eyes (9.5%); however, there was no shift to penetrating keratoplasty. Air-bubble tamponade was performed in 7 eyes (33.3%) for postoperative gapping of the graft. There were 2 failed grafts (9.5%) due to corneal ulcer while all the other grafts remained clear throughout follow-up. The mean preoperative best-corrected visual acuity (BCVA) was 1.84 ± 0.66 logMAR, which improved to 0.74 ± 0.63 (P < 0.01). The average sphere power was − 0.88 ± 3.88 diopter (D), average cylinder power 3.03 ± 1.46D, and average endothelial count 1877 ± 375 cells/mm2. CONCLUSION: In severe ocular surface diseases, big-bubble technique frequently failed to separate predescemtic plane; however, it effectively created air-filled stroma which was easier to remove. Although BCVA was suboptimal due to ocular surface disorders, graft survival and clarity rate is high, justifying the application of DALK in these cases. PMID:29296551

  20. Corneal avascularity is due to soluble VEGF receptor-1

    PubMed Central

    Ambati, Balamurali K.; Nozaki, Miho; Singh, Nirbhai; Takeda, Atsunobu; Jani, Pooja D.; Suthar, Tushar; Albuquerque, Romulo J. C.; Richter, Elizabeth; Sakurai, Eiji; Newcomb, Michael T.; Kleinman, Mark E.; Caldwell, Ruth B.; Lin, Qing; Ogura, Yuichiro; Orecchia, Angela; Samuelson, Don A.; Agnew, Dalen W.; Leger, Judy St.; Green, W. Richard; Mahasreshti, Parameshwar J.; Curiel, David T.; Kwan, Donna; Marsh, Helene; Ikeda, Sakae; Leiper, Lucy J.; Collinson, J. Martin; Bogdanovich, Sasha; Khurana, Tejvir S.; Shibuya, Masabumi; Baldwin, Megan E.; Ferrara, Napoleone; Gerber, Hans-Peter; Falco, Sandro De; Witta, Jassir; Baffi, Judit Z.; Raisler, Brian J.; Ambati, Jayakrishna

    2009-01-01

    Corneal avascularity—the absence of blood vessels in the cornea—is required for optical clarity and optimal vision, and has led to the cornea being widely used for validating pro- and anti-angiogenic therapeutic strategies for many disorders1-4. But the molecular underpinnings of the avascular phenotype have until now remained obscure5-10 and are all the more remarkable given the presence in the cornea of vascular endothelial growth factor (VEGF)-A, a potent stimulator of angiogenesis, and the proximity of the cornea to vascularized tissues. Here we show that the cornea expresses soluble VEGF receptor-1 (sVEGFR-1; also known as sflt-1) and that suppression of this endogenous VEGF-A trap11 by neutralizing antibodies, RNA interference or Cre-lox-mediated gene disruption abolishes corneal avascularity in mice. The spontaneously vascularized corneas of corn1 and Pax6+/− mice12,13 and Pax6+/− patients with aniridia14 are deficient in sflt-1, and recombinant sflt-1 administration restores corneal avascularity in corn1 and Pax6+/− mice. Manatees, the only known creatures uniformly to have vascularized corneas15, do not express sflt-1, whereas the avascular corneas of dugongs, also members of the order Sirenia, elephants, the closest extant terrestrial phylogenetic relatives of manatees, and other marine mammals (dolphins and whales) contain sflt-1, indicating that it has a crucial, evolutionarily conserved role. The recognition that sflt-1 is essential for preserving the avascular ambit of the cornea can rationally guide its use as a platform for angiogenic modulators, supports its use in treating neovascular diseases, and might provide insight into the immunological privilege of the cornea. PMID:17051153

  1. Imaging and quantification of endothelial cell loss in eye bank prepared DMEK grafts using trainable segmentation software.

    PubMed

    Jardine, Griffin J; Holiman, Jeffrey D; Stoeger, Christopher G; Chamberlain, Winston D

    2014-09-01

    To improve accuracy and efficiency in quantifying the endothelial cell loss (ECL) in eye bank preparation of corneal endothelial grafts. Eight cadaveric corneas were subjected to Descemet Membrane Endothelial Keratoplasty (DMEK) preparation. The endothelial surfaces were stained with a viability stain, calcein AM dye (CAM) and then captured by a digital camera. The ECL rates were quantified in these images by three separate readers using trainable segmentation, a plug-in feature from the imaging software, Fiji. Images were also analyzed by Adobe Photoshop for comparison. Mean times required to process the images were measured between the two modalities. The mean ECL (with standard deviation) as analyzed by Fiji was 22.5% (6.5%) and Adobe was 18.7% (7.0%; p = 0.04). The mean time required to process the images through the two different imaging methods was 19.9 min (7.5) for Fiji and 23.4 min (12.9) for Adobe (p = 0.17). Establishing an accurate, efficient and reproducible means of quantifying ECL in graft preparation and surgical techniques can provide insight to the safety, long-term potential of the graft tissues as well as provide a quality control measure for eye banks and surgeons. Trainable segmentation in Fiji software using CAM is a novel approach to measuring ECL that captured a statistically significantly higher percentage of ECL comparable to Adobe and was more accurate in standardized testing. Interestingly, ECL as determined using both methods in eye bank-prepared DMEK grafts exceeded 18% on average.

  2. Visual acuity, endothelial cell density and polymegathism after iris-fixated lens implantation.

    PubMed

    Nassiri, Nader; Ghorbanhosseini, Saeedeh; Jafarzadehpur, Ebrahim; Kavousnezhad, Sara; Nassiri, Nariman; Sheibani, Kourosh

    2018-01-01

    The purpose of this study was to evaluate the visual acuity as well as endothelial cell density (ECD) and polymegathism after iris-fixated lens (Artiflex ® AC 401) implantation for correction of moderate to high myopia. In this retrospective cross-sectional study, 55 eyes from 29 patients undergoing iris-fixated lens implantation for correction of myopia (-5.00 to -15.00 D) from 2007 to 2014 were evaluated. Uncorrected visual acuity, best spectacle-corrected visual acuity, refraction, ECD and polymegathism (coefficient of variation [CV] in the sizes of endothelial cells) were measured preoperatively and 6 months postoperatively. In the sixth month of follow-up, the uncorrected vision acuity was 20/25 or better in 81.5% of the eyes. The best-corrected visual acuity was 20/30 or better in 96.3% of the eyes, and more than 92% of the eyes had a refraction score of ±1 D from the target refraction. The mean corneal ECD of patients before surgery was 2,803±339 cells/mm 2 , which changed to 2,744±369 cells/mm 2 six months after surgery ( p =0.142). CV in the sizes of endothelial cells before the surgery was 25.7%±7.1% and six months after surgery it was 25.9%±5.4% ( p =0.857). Artiflex iris-fixated lens implantation is a suitable and predictable method for correction of moderate to high myopia. There was no statistically significant change in ECD and polymegathism (CV in the sizes of endothelial cells) after 6 months of follow-up.

  3. Effect of deoxyribozymes targeting c-Jun on solid tumor growth and angiogenesis in rodents.

    PubMed

    Zhang, Guishui; Dass, Crispin R; Sumithran, Eric; Di Girolamo, Nick; Sun, Lun-Quan; Khachigian, Levon M

    2004-05-05

    The basic region-leucine zipper protein c-Jun has been linked to cell proliferation, transformation, and apoptosis. However, a direct role for c-Jun in angiogenesis has not been shown. We used human microvascular endothelial cells (HMEC-1) transfected with a DNAzyme targeting the c-Jun mRNA (Dz13), related oligonucleotides, or vehicle in in vitro models of microvascular endothelial cell proliferation, migration, chemoinvasion, and tubule formation, a rat model of corneal neovascularization, and a mouse model of solid tumor growth and vascular endothelial growth factor (VEGF)-induced angiogenesis. All statistical tests were two-sided. Compared with mock-transfected cells, HMEC-1 cells transfected with Dz13 expressed less c-Jun protein and possessed lower DNA-binding activity. Dz13 blocked endothelial cell proliferation, migration, chemoinvasion, and tubule formation. Dz13 inhibited the endothelial cell expression and proteolytic activity of MMP-2, a c-Jun-dependent gene. Dz13 inhibited VEGF-induced neovascularization in the rat cornea compared with vehicle control (Dz13 versus vehicle: 4.0 neovessels versus 30.7 neovessels, difference = 26.7 neovessels; P =.004; area occupied by new blood vessels for Dz13 versus vehicle: 0.35 mm2 versus 1.52 mm2, difference = 1.17 mm2; P =.005) as well as solid melanoma growth in mice (Dz13 versus vehicle at 14 days: 108 mm3 versus 283 mm3, difference = 175 mm3; P =.006) with greatly reduced vascular density (Dz13 versus vehicle: 30% versus 100%, difference = 70%; P<.001). DNAzymes targeting c-Jun may have therapeutic potential as inhibitors of tumor angiogenesis and growth.

  4. Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK).

    PubMed

    Koenig, Steven B; Covert, Douglas J; Dupps, William J; Meisler, David M

    2007-07-01

    To evaluate visual acuity, refractive outcomes, and endothelial cell density 6 months after Descemet stripping and automated endothelial keratoplasty (DSAEK). We performed an institutional review board-approved prospective study of a surgical case series of 34 patients at 2 institutions undergoing DSAEK for Fuchs endothelial dystrophy, pseudophakic bullous keratopathy, or aphakic bullous keratopathy with or without simultaneous phacoemulsification and intraocular lens implantation. Clinical outcomes, including best spectacle-corrected visual acuity (BSCVA), spherical equivalent refraction, and refractive astigmatism and topographic or keratometric astigmatism, were assessed at the 6-month postoperative examination and compared with preoperative values with paired Student t tests. The change in endothelial cell density from the eye bank examination to 6 months after transplantation was similarly evaluated. BSCVA averaged 20/99 preoperatively and 20/42 postoperatively (P < 0.0001). After DSAEK, 30 (88.2%) of 34 patients showed improved BSCVA, and 21 (61.8%) of the 34 patients achieved a BSCVA of 20/40 or better. For patients not undergoing simultaneous phacoemulsification and intraocular lens implantation, a hyperopic shift in refraction of 1.19 +/- 1.32 D was noted. Refractive astigmatism, topographic astigmatism, and keratometry showed no statistically significant change. Endothelial cell density of donor corneas averaged 2826 +/- 370 cells/mm, whereas the mean postoperative density was 1396 +/- 440 cells/mm. This finding corresponded to an average loss of 1426 cells/mm (50% loss; P = 0.0001). The first half of cases experienced an average cell loss of 1674 cells/mm (59% loss) compared with 1181 (41% loss) in the second half of cases (P = 0.005). Three (9%) of 34 grafts experienced iatrogenic graft failure and required reoperation with new donor tissue. Also, 9 (27%) of 34 grafts experienced dislocation in the early postoperative period and required repositioning. In this prospective study of DSAEK for bullous keratopathy and Fuchs endothelial corneal dystrophy, improvement of visual acuity was achieved with only a mild tendency toward hyperopic shift and without significant induced astigmatism. Endothelial cell loss was significant, however, and may be related to surgical experience.

  5. Diclofenac sodium delivery to the eye: in vitro evaluation of novel solid lipid nanoparticle formulation using human cornea construct.

    PubMed

    Attama, Anthony A; Reichl, Stephan; Müller-Goymann, Christel C

    2008-05-01

    Solid lipid nanoparticles (SLNs) were prepared with a combination of homolipid from goat (goat fat) and phospholipid, and evaluated for diclofenac sodium (DNa) delivery to the eye using bio-engineered human cornea, produced from immortalized human corneal endothelial cells (HENC), stromal fibroblasts and epithelial cells CEPI 17 CL 4. Encapsulation efficiency was high and sustained release of DNa and high permeation through the bio-engineered cornea were achieved. Results obtained in this work showed that permeation of DNa through the cornea construct was improved by formulation as SLN modified with phospholipid.

  6. Organ culture storage of pre-prepared corneal donor material for Descemet's membrane endothelial keratoplasty.

    PubMed

    Bhogal, Maninder; Matter, Karl; Balda, Maria S; Allan, Bruce D

    2016-11-01

    To evaluate the effect of media composition and storage method on pre-prepared Descemet's membrane endothelial keratoplasty (DMEK) grafts. 50 corneas were used. Endothelial wound healing and proliferation in different media were assessed using a standard injury model. DMEK grafts were stored using three methods: peeling with free scroll storage; partial peeling with storage on the stroma and fluid bubble separation with storage on the stroma. Endothelial cell (EC) phenotype and the extent of endothelial overgrowth were examined. Global cell viability was assessed for storage methods that maintained a normal cell phenotype. 1 mm wounds healed within 4 days. Enhanced media did not increase EC proliferation but may have increased EC migration into the wounded area. Grafts that had been trephined showed evidence of EC overgrowth, whereas preservation of a physical barrier in the bubble group prevented this. In grafts stored in enhanced media or reapposed to the stroma after trephination, endothelial migration occurred sooner and cells underwent endothelial-mesenchymal transformation. Ongoing cell loss, with new patterns of cell death, was observed after returning grafts to storage. Grafts stored as free scrolls retained more viable ECs than grafts prepared with the fluid bubble method (74.2± 3% vs 60.3±6%, p=0.04 (n=8). Free scroll storage is superior to liquid bubble and partial peeling techniques. Free scrolls only showed overgrowth of ECs after 4 days in organ culture, indicating a viable time window for the clinical use of pre-prepared DMEK donor material using this method. Methods for tissue preparation and storage media developed for whole corneas should not be used in pre-prepared DMEK grafts without prior evaluation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. [The cornea: stasis and dynamics].

    PubMed

    Nishida, Teruo

    2008-03-01

    The physiological roles of the cornea are to conduct external light into the eye, focus it, together with the lens, onto the retina, and to provide rigidity to the entire eyeball. Good vision thus requires maintenance of the transparency and proper refractive shape of the cornea. Although the cornea appears to be a relatively static structure, dynamic processes operate within and around the cornea at the tissue, cell, and molecular level. In this article, I review the mechanisms responsible for maintenance of corneal homeostasis as well as the development of new modes of treatment for various corneal diseases. I. The static cornea: structure and physiological functions. The cornea is derived from ectoderm, so that it can be considered as transparent skin. It is devoid of blood vessels and manifests the highest sensitivity in the entire body. The surface of the cornea is covered by tear fluid, which serves both as a lubricant and as a conduit for regulatory molecules. The cornea is also supplied with oxygen and various nutrients by the aqueous humor and a loop vascular system in addition to tear fluid. The cornea interacts with its surrounding tissues directly as well as indirectly through tear fluid or aqueous humor, with such interactions playing an important role in the regulation of corneal structure and functions. The resident cells of the cornea-epithelial cells, fibroblasts (keratocytes), and endothelial cells--also engage in mutual interactions through network systems. These interactions as well as those with infiltrated cells and regulation by nerves contribute to the maintenance of the normal structure and functions of the cornea as well as to the repair of corneal injuries. II. The dynamic cornea: maintenance of structure and functions by network systems. Developments in laser and computer technology have allowed observation of the cells and collagen fibers within the cornea. Furthermore, progress in cell and molecular biology has allowed characterization of dynamic network systems-including cell-cell and cell-extracellular matrix interactions as well as cytokines and neural factors-that contribute to the maintenance of corneal transparency and shape. III. Disruption of network systems: persistent corneal epithelial defects and corneal ulcer. Selection of the appropriate treatment for pathologic lesions of the cornea and the accompanying decrease in visual acuity requires localization of the lesion with regard to the epithelium, stroma, or endothelium of the cornea. In certain instances, however, it is not possible to determine the cause of the problem within the cornea. In such cases, the cause of the pathologic lesion and the target for treatment may lie in the surrounding tissues or environment. For example, corneal epithelial wound healing may be delayed, leading to the development of persistent epithelial defects, as a result of disruption of intercellular junctions between epithelial cells, an abnormality of the corneal basement membrane, altered concentrations of various cytokines in tear fluid, a lowered corneal sensation, or allergic reactions in the lid conjunctiva. Loss of corneal epithelial barrier function can further allow inflammatory cytokines present in tear fluid, together with infiltrated cells, to activate keratocytes and elicit excessive degradation of collagen in the stroma, thereby giving rise to corneal ulcer. IV. Development of new drugs for corneal diseases. We have attempted to apply the results of basic scientific research to the development of new drugs for corneal diseases that remain difficult to treat. The process of authorization for new drugs from the Ministry of Health, Labor, and Welfare takes more than two decades, however. The path from the bench to clinical practice is thus a long one. 1. Development of eyedrops for treatment of persistent corneal epithelial defects. We demonstrated the clinical efficacy of fibronectin eyedrops for the treatment of persistent epithelial defects of the cornea. However, the possibility of blood-borne infections has interfered with the development of serum-derived fibronectin as a drug. An automated machine for the preparation of autologous fibronectin eyedrops has therefore recently been developed. Furthermore, in seeking an alternative to fibronectin eyedrops, we are investigating the effects of a peptide corresponding to the second cell-binding domain of fibronectin on corneal epithelial wound healing. Considering that urokinase-type plasminogen activator may be expressed at the site of corneal epithelial defects and facilitates epithelial migration, the potential clinical application of annexin V, which stimulates the secretion of urokinase-type plasminogen activator for the treatment of persistent corneal epithelial defects is also now under investigation in Japan. 2. Development of eyedrops for treatment of neurotrophic keratopathy. Substance P, a neurotransmitter, stimulates corneal epithelial migration in a synergistic manner with insulin-like growth factor (IGF)--1. We have shown that eyedrops containing both the substance P-derived peptide FGLM-amide and the IGF-1--derived peptide SSSR are effective for the treatment of persistent corneal epithelial defects in individuals with diabetic keratopathy or neurotrophic keratopathy, both of which are associated with a reduction in corneal sensation. 3. Development of drugs for corneal ulcer. Treatment of corneal infection with antibiotics does not necessarily halt the process of corneal ulceration, which is characterized by excessive degradation of stromal collagen, or resolve persistent corneal epithelial defects. In addition to eyedrops for the treatment of persistent corneal epithelial defects, we have therefore also been working on the development of new drugs for the treatment of corneal ulcer. To this end, we have established an experimental system in which corneal fibroblasts are cultured in a three-dimensional collagen gel. With this system, we have shown that triptolide and steroids inhibit collagen degradation by corneal fibroblasts. Triptolide or its derivatives are thus potential drugs for the treatment of corneal ulcer and would work by acting directly on corneal fibroblasts rather than by inhibiting the secreted enzymes(matrix metalloproteinases) responsible for collagen degradation.

  8. A Randomized Multicenter Clinical Trial of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) versus DSAEK.

    PubMed

    Dickman, Mor M; Kruit, Pieter J; Remeijer, Lies; van Rooij, Jeroen; Van der Lelij, Allegonda; Wijdh, Robert H J; van den Biggelaar, Frank J H M; Berendschot, Tos T J M; Nuijts, Rudy M M A

    2016-11-01

    To compare visual acuity, refraction, endothelial cell density (ECD), and complications after Descemet stripping automated endothelial keratoplasty (DSAEK) and ultrathin DSAEK (UT-DSAEK). A multicenter, prospective, double-masked, randomized, controlled clinical trial. From 66 patients with irreversible corneal endothelial dysfunction dues to Fuchs' dystrophy who enrolled from 4 tertiary medical centers in the Netherlands, 66 eyes were studied. Participants were centrally randomized to undergo either UT-DSAEK or DSAEK, based on preoperative best spectacle-corrected visual acuity (BSCVA), recipient central corneal thickness, patient age, and recruitment center. Donor corneas were precut by a single cornea bank. Participants underwent ophthalmic examinations preoperatively and 3, 6, and 12 months after the operation, including manifest refraction, BSCVA using an Early Treatment Diabetic Retinopathy Study chart, and endothelium imaging. BSCVA 12 months postoperatively. Preoperative BSCVA did not differ between patients undergoing DSAEK (0.35 logarithm of the minimum angle of resolution [logMAR] [95% confidence interval {CI} 0.27-0.43]; n = 32) and UT-DSAEK (0.37 logMAR [95% CI 0.31-0.43]; n = 34; P = 0.8). BSCVA was significantly better after UT-DSAEK compared with that after DSAEK at 3 months (0.17 logMAR [95% CI 0.13-0.21], n = 31 vs. 0.28 logMAR [95% CI 0.23-0.33], n = 31; P = 0.001), 6 months (0.14 logMAR [95% CI 0.10-0.18], n = 30 vs. 0.24 logMAR [95% CI 0.20-0.28], n = 30; P = 0.002), and 12 months (0.13 logMAR [95% CI 0.09-0.17], n = 33 vs. 0.20 logMAR [95% CI 0.15-0.25], n = 29; P = 0.03). Refraction, ECD loss (40% at 3 months; P < 0.001), donor loss (DSAEK n = 2 vs. UT-DSAEK n = 3 [relative risk {RR} 1.4 {95% CI 0.24-7.5}; P = 0.7]), and graft dislocation (DSAEK n = 5 vs. UT-DSAEK n = 5 [RR 1.0 {95% CI 0.34-3.33}; P = 0.9]) did not differ between UT-DSAEK and DSAEK. Donor thickness was significantly thinner for UT-DSAEK (101 μm [95% CI 93-110 μm]; range 50-145 μm) than for DSAEK (209 μm [95% CI 196-222 μm]; range 147-289 μm; P < 0.001). This study indicates that compared with DSAEK, UT-DSAEK results in faster and better recovery of BSCVA with similar refractive outcomes, endothelial cell loss, and incidence of complications. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  9. Randomized Controlled Trial Comparing Transepithelial Corneal Cross-linking Using Iontophoresis with the Dresden Protocol in Progressive Keratoconus.

    PubMed

    Lombardo, Marco; Giannini, Daniela; Lombardo, Giuseppe; Serrao, Sebastiano

    2017-06-01

    To compare clinical outcomes of transepithelial corneal cross-linking using iontophoresis (T-ionto CL) and standard corneal cross-linking (standard CL) for the treatment of progressive keratoconus 12 months after the operation. Prospective randomized controlled clinical trial. Thirty-four eyes of 25 participants with progressive keratoconus were randomized into T-ionto CL (22 eyes) or standard CL (12 eyes). T-ionto CL was performed using an iontophoresis device with dextran-free 0.1% riboflavin-5-phosphate solution with enhancers and by irradiating the cornea with a 10 mW/cm 2 ultraviolet A device for 9 minutes. Standard CL was performed according to the Dresden protocol. The primary outcome measure was stabilization of keratoconus after 12 months through analysis of maximum simulated keratometry readings (K max , diopters). Other outcome measures were corrected distance visual acuity (CDVA, logarithm of the minimum angle of resolution [logMAR]), manifest spherical equivalent refraction (D), central corneal thickness (CCT, micrometers) and endothelial cell density (ECD). Follow-up examinations were arranged at 3 and 7 days and 1, 3, 6, and 12 months. Twelve months after T-ionto CL and standard CL, K max on average flattened by -0.52±1.30 D (P = 0.06) and -0.82±1.20 D (P = 0.04), respectively. The mean change in CDVA was -0.10±0.12 logMAR (P = 0.003) and -0.03±0.06 logMAR (P = 0.10) after T-ionto CL and standard CL, respectively. The manifest spherical equivalent refraction changed on average by +0.71±1.44 D (P = 0.03) and +0.21±0.76 D (P = 0.38), respectively. The CCT and ECD measures did not change significantly in any group at 12 months. Significant differences in the outcome measures between treatments were found in the first week postoperatively. No complications occurred in the T-ionto CL group; 1 eye (8%) had sterile corneal infiltrates, which did not affect the final visual acuity, in the standard CL group. Significant visual and refractive improvements were found 12 months after T-ionto CL, though the average improvement in corneal topography readings was slightly lower than the Dresden protocol in the same period. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. Air-guided manual deep lamellar keratoplasty.

    PubMed

    Caporossi, A; Simi, C; Licignano, R; Traversi, C; Balestrazzi, A

    2004-01-01

    To evaluate the efficacy of a new modified technique of deep lamellar keratoplasty (DLK). Nine eyes of eight patients with keratoconus of moderate degree were included. All patients underwent DLK with manual dissection from a limbal side port after an air bubble injection in the anterior chamber. The patients underwent a complete ophthalmologic examination 6 months after the suture removal, evaluating best-corrected visual acuity, corneal thickness, endothelial cell count, and topographic astigmatism. One case (11.1%) was converted to penetrating keratoplasty because of microperforation. In the eight successful cases, 7 eyes (77.8%) achieved 20/30 or better visual acuity 6 months after suture removal. Mean postoperative pachymetry was 604.76 microm (SD 46.76). Specular microscopy 6 months after suture removal revealed average endothelial cell count of 2273/mm2 (SD 229). This modified DLK technique is a safe and effective procedure and could facilitate, after a short learning curve, this kind of surgery with a low risk of conversion to penetrating keratoplasty.

  11. Imaging of soft material with carbon nanotube tip using near-field scanning microwave microscopy.

    PubMed

    Wu, Zhe; Sun, Wei-Qiang; Feng, Tao; Tang, Shawn Wenjie; Li, Gang; Jiang, Kai-Li; Xu, Sheng-Yong; Ong, Chong Kim

    2015-01-01

    In this manuscript, a near-field scanning microwave microscope (NSMM) of our own design is introduced while using a multi-walled carbon nanotube (MWCNT) bundle as the tip (referred to as 'CNT tip'). Clear images of gold-patterned numbers, photoresist stripes and corneal endothelial cells (cell line B4G12) were obtained by mapping the resonant frequency fr and S11 amplitude of a given area while the NSMM is operating in tapping mode. The CNT tip helps to improve image quality and reveals more information about the sample as compared to a traditional metallic tip. The CNT tip is flexible and does not scratch the surface of the sample during the scan, which is useful for imaging soft material in biological science. In the imaging of the B4G12 endothelial cells, the nuclei and cytoplasm can be clearly distinguished from the rest of the cell and its surrounding medium. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Slit-lamp technique of draining interface fluid following Descemet's stripping endothelial keratoplasty.

    PubMed

    Srinivasan, Sathish; Rootman, David S

    2007-09-01

    To describe a new slit-lamp technique for draining interface fluid to manage complete donor disc detachments following Descemet's stripping (automated) endothelial keratoplasty (DSEK/DSAEK). Interventional case series. Five DSEK/DSAEK patients presented on the first postoperative day with complete detachment of the donor lenticule. Slit-lamp biomicroscopy showed interface fluid preventing attachment of the donor disc to the host stromal bed. A new slit-lamp technique is described to drain the interface fluid. This technique involved completely filling the anterior chamber with an air bubble using a 30-gauge needle on a 3 ml syringe. Following this, a 0.12 forceps was used to open the inferior mid-peripheral corneal drainage slit to drain the interface fluid. This technique was successful in draining the interface fluid in all five patients, leading to immediate complete reattachment of the donor disc. Donor disc detachments following DSEK/DSAEK can be successfully managed by this slit-lamp technique of draining the interface fluid.

  13. Effects of trypan blue on corneal endothelium and anterior lens capsule in albino wistar rats: An investigator-masked, controlled, two-period, experimental study

    PubMed Central

    Ari, Seyhmus; Çaça, Ihsan; Ünlü, Kaan; Nergiz, Yusuf; Aksit, Ihsan

    2006-01-01

    Background: The development of continuous curvilinear capsulorrhexis (CCC) has contributed significantly to the tolerability and effectiveness of cataract extraction and intraocular lens implantation. Staining of the anterior capsule has become a popular method of increasing visibility when performing CCC. Objective: The aim of this study was to determine, using scanning electron microscopy (SEM) and transmission electron microscopy (TEM), the highest concentrations of trypan blue dye that would not cause long-term toxicity after injection into the anterior chamber of rat eyes. Methods: The eyes of healthy female albino Wistar rats were used in this investigator-masked, controlled, 2-period, experimental study conducted over 12 weeks at the Dicle University Experimental Animal Laboratory, Diyarbakir, Turkey. The rats were randomly divided into 5 groups of 4 using a random-number table. Each rat was administered a 0.05-mL injection of trypan blue into the right eye in 1 of the following concentrations: 0.4%, 0.2%, 0.1%, 0.05%, or 0.025%. A 0.05-mL pH-balanced saline solution was injected into the left eye of each rat to act as a control. At 1 day after injection and 4 weeks after injection (early period), 1 rat from each concentration group was euthanized and their eyes were enucleated. At 12 weeks after injection (late period) the remaining 2 rats from each group were euthanized and their eyes were enucleated. Corneal endothelial cells and the anterior lens capsule of the enucleated eyes were analyzed using SEM and TEM, and the results were compared with those of the control group. In the TEM analysis, the primary end point was the histopathologic changes in the cellular organelles when compared with those in the control group. In the SEM analysis, the primary end point was changes in cell shape, intracellular junctions, and density of the microvilli when compared with those in the control group. Results: Forty eyes from 20 albino Wistar rats (mean [SD] age, 8.2 [1.6] weeks; mean [SD] weight, 175.6 [16.5] g) were used in the study. Each group of rats received a different concentration of trypan blue in the right eye. In the early period, both the 0.4% and 0.2% concentrations were associated with the impairment of the hexagonal structure of corneal endothelial cells and intercellular junctions. Those concentrations were also associated with an increased occurrence of cellular vacuolation, cytoplasmic edema, extensive granulation of the endoplasmic reticulum, pyknotic nuclei, and mitochondrial degeneration. In the late period, these changes were observed as persisting in a decreasing manner. With the 0.1% and 0.05% concentrations, the density of microvilli decreased, nuclei appeared normal, granulation of the endoplasmic reticulum and Golgi apparatus was active, and minimal levels of mitochondrial degeneration were observed. Conclusions: In this small experimental study in rat eyes, trypan blue at concentrations >0.025% was associated with impaired morphology and structure of corneal endothelial cells after short-term exposure. This effect continued in a decreasing fashion after long-term exposure. No significant changes were noted in the control group or the group administered the 0.025% concentration. PMID:24678109

  14. Early changes in morphology and intraocular pressure by size of clear corneal incision.

    PubMed

    Cheng, Bing; Liu, Yi; Liu, Yizhi; Xie, Bin Bin; Xi, Lei; Yang, Ye

    2011-06-01

    We compared changes in morphology and intraocular pressure (IOP) induced by clear 2.2-mm and 3.0-mm corneal incisions in a cohort of patients with cataracts. In 160 eyes (from 70 men and 90 women at the Ophthalmic Center of Sun Yat-sen University), optical coherence tomography and tonometry were performed at 1, 5, and 24 hours after cataract surgery. The main outcome measures were IOP, postoperative changes in Descemet membrane detachment (DMD), healing of the surgical incision, and inflammation of the anterior chamber. Five hours after surgery, patients with 2.2-mm and 3.0-mm incisions had lower IOPs (P < 0.017) as measured by noncontact tonometry, but the difference was significant only among patients with grade V cataracts (2.2 mm, 12.6 ± 1.2 mm Hg; 3.0 mm, 14.5 ± 0.9 mm Hg, P < 0.05). The incidence of endothelial gap at 24 hours after surgery was significantly higher in the 2.2-mm (50%) versus 3.0-mm (11.1%) group of patients with grade V cataracts (P < 0.05). The incidence of DMD at 5 hours was also significantly higher in the 2.2-mm group (75%) than in the 3.0-mm group (22.2%) only among patients with this grade (P < 0.05). Incision width made no difference among patients with grade I-IV lens nuclei; but among those with grade V, 3.0-mm incisions had significantly less endothelial gaping, less DMD, and higher mean IOPs. For these patients, smaller incisions may not be optimal, and eyes may be especially vulnerable within 5 hours of surgery.

  15. [Long-term outcomes of Ahmed glaucoma valve implantation for treating refractory glaucoma].

    PubMed

    Xu, Yumei; Hong, Tao; Li, Wanming

    2015-02-10

    To explore the efficacies and complications of Ahmed glaucoma valve implantation for treating refractory glaucoma. A retrospective study of case series was conducted for 24 patients (26 eyes) with refractory glaucoma from February 2001 to July 2008 at our hospital. Ahmed glaucoma valve implantation was performed. Pre- and post-operative best spectacle-corrected visual acuity (BSCVA), intraocular pressure (IOP), number of medications and complications were recorded and analyzed. The follow-up period was 58-159 months. The post-operative values of IOP were 13.02+/-6.79, 11.43+/-5.24 and 18.56+/-6.43 mmHg at 1 day, 1 month and the last follow-up respectively. There were significant difference when compared with pre-operative IOP (37.59+/-10.76 mmHg, P < 0.01). And 65.38% of eyes maintained or gained ≥ 1 line of BSCVA. But there was no significant difference with pre-operative BSCVA (P = 0.110). Twenty eyes required anti-glaucoma drugs after glaucoma valve implantation and the average number of medication was 1.72+/-0.98. There was significant difference with the pre-operative medication number 2.7 ± 0.7 (P = 0.001). The surgical success rate was 73.1%. And the causes of failure were endophthalmitis, corneal endothelial decompensation, persistent conjunctival wound non-healing, glaucoma valve exposure and loss of light perception.Early postoperative complications were ocular hypotony, shallow anterior chamber, hyphema, transient high IOP and tube occlusion. And long-term complications included encapsulated cyst formation, tube exposure, corneal endothelial decompensation and endophthalmitis. Ahmed glaucoma valve implantation is efficacious for refractory glaucoma.However, clinicians should pay attention to the prevention and treatment of complications.

  16. Effect of charge and molecular weight on the functionality of gelatin carriers for corneal endothelial cell therapy.

    PubMed

    Lai, Jui-Yang; Lu, Pei-Lin; Chen, Ko-Hua; Tabata, Yasuhiko; Hsiue, Ging-Ho

    2006-06-01

    Cell transplantation strategies usually involve the use of supporting carrier materials because of the soft and fragile nature of these grafts. In this work, a cell-adhesive gelatin hydrogel carrier was fabricated to deliver cultivated human corneal endothelial cell (HCEC) sheets, which were harvested from thermo-responsive poly(N-isopropylacrylamide) (PNIPAAm)-grafted culture surfaces. The carrier disks, consisting of gelatins with a different isoelectric point (IEP = 5.0 and 9.0) and a molecular weight (MW) ranging from 3 to 100 kDa, were subjected to 16.6 kGy gamma irradiation for sterilization. The effect of IEP and MW of the raw gelatins (i.e., before irradiation) on the functionality of sterilized disks was studied by determinations of mechanical property, water content, dissolution degree, and cytocompatibility. Irrespective of the IEP of raw gelatin, hydrogel disks prepared with high MW (100 kDa) exhibited a greater tensile strength, lower water content, and slower dissolution rate than those made of low MW gelatin (8 and 3 kDa). From the investigation of cellular responses to the disks, the negatively charged gelatin (IEP = 5.0) groups were more cytocompatible when compared with their positively charged counterparts (IEP = 9.0) at the same MW (100 kDa). Additionally, in the negatively charged gelatin groups, only a slight increase in pro-inflammatory cytokine expression was observed with increasing MW of gelatin from 3 to 100 kDa. It is concluded that the gamma-sterilized hydrogel disks made from raw gelatins (IEP = 5.0, MW = 100 kDa) with appropriate dissolution degree and acceptable cytocompatibility are capable of providing stable mechanical support, making these carriers promising candidates for intraocular delivery of cultivated HCEC sheets.

  17. Effect of trapping vascular endothelial growth factor-A in a murine model of dry eye with inflammatory neovascularization.

    PubMed

    Kwon, Jin Woo; Choi, Jin A; Shin, Eun Young; La, Tae Yoon; Jee, Dong Hyun; Chung, Yeon Woong; Cho, Yang Kyung

    2016-01-01

    To evaluate whether trapping vascular endothelial growth factor A (VEGF-A) would suppress angiogenesis and inflammation in dry eye corneas in a murine corneal suture model. We established two groups of animals, one with non-dry eyes and the other with induced dry eyes. In both groups, a corneal suture model was used to induce inflammation and neovascularization. Each of two groups was again divided into three subgroups according to the treatment; subgroup I (aflibercept), subgroup II (dexamethasone) and subgroup III (phosphate buffered saline, PBS). Corneas were harvested and immunohistochemical staining was performed to compare the extents of neovascularization and CD11b+ cell infiltration. Real-time polymerase chain reaction was performed to quantify the expression of inflammatory cytokines and VEGF-A in the corneas. Trapping VEGF-A with aflibercept resulted in significantly decreased angiogenesis and inflammation compared with the dexamethasone and PBS treatments in the dry eye corneas (all P <0.05), but with no such effects in non-dry eyes. The anti-inflammatory and anti-angiogenic effects of VEGF-A trapping were stronger than those of dexamethasone in both dry eye and non-dry eye corneas (all P <0.05). The levels of RNA expression of VEGF-A, TNF-alpha, and IL-6 in the aflibercept subgroup were significantly decreased compared with those in the PBS subgroup in the dry eye group. Compared with non-dry eye corneas, dry eye corneas have greater amounts of inflammation and neovascularization and also have a more robust response to anti-inflammatory and anti-angiogenic agents after ocular surface surgery. Trapping VEGF-A is effective in decreasing both angiogenesis and inflammation in dry eye corneas after ocular surface surgery.

  18. Increased sensitivity of the non-human primate eye to microwave radiation following ophthalmic drug pretreatment.

    PubMed

    Kues, H A; Monahan, J C; D'Anna, S A; McLeod, D S; Lutty, G A; Koslov, S

    1992-01-01

    Previous studies in our laboratory have established that pulsed microwaves at 2.45 GHz and 10 mW/cm2 are associated with production of corneal endothelial lesions and with disruption of the blood-aqueous barrier in the non-human primate eye. In the study reported here we examined ocular damage in monkeys (M. mulatta and M. fascicularis) following topical treatment with one of two ophthalmic drugs (timolol maleate and pilocarpine) that preceded exposure to pulsed microwaves. Anesthetized monkeys were sham exposed or exposed to pulsed, 2.45 GHz microwaves (10 microseconds, 100 pps) at average power densities of 0.2, 1, 5, 10, or 15 mW/cm2 4 h a day for 3 consecutive days (respective SARs were 0.052, 0.26, 1.3, 2.6, and 3.9 W/kg). Immediately before microwave exposure, one or both eyes were treated topically with one drop of 0.5% timolol maleate or of 2% pilocarpine. Following administration of a drug, we observed a significant reduction in the power-density threshold (from 10 to 1 mW/cm2) for induction of corneal endothelial lesions and for increased vascular permeability of the iris. Diagnostic procedures (in vivo specular microscopy and fluorescein iris angiography) were performed following each exposure protocol. In addition, increased vascular permeability was confirmed with horseradish peroxidase tracer techniques. Although we did not measure intraocular temperatures in experimental animals, the results suggest that a mechanism other than significant heating of the eye is involved. Our data indicate that pulsed microwaves at an average SAR of 0.26 W/kg, if administered after pretreatment with ophthalmic drugs, can produce significant ocular effects in the anesthetized primate.

  19. Effect of trapping vascular endothelial growth factor-A in a murine model of dry eye with inflammatory neovascularization

    PubMed Central

    Kwon, Jin Woo; Choi, Jin A; Shin, Eun Young; La, Tae Yoon; Jee, Dong Hyun; Chung, Yeon Woong; Cho, Yang Kyung

    2016-01-01

    AIM To evaluate whether trapping vascular endothelial growth factor A (VEGF-A) would suppress angiogenesis and inflammation in dry eye corneas in a murine corneal suture model. METHODS We established two groups of animals, one with non-dry eyes and the other with induced dry eyes. In both groups, a corneal suture model was used to induce inflammation and neovascularization. Each of two groups was again divided into three subgroups according to the treatment; subgroup I (aflibercept), subgroup II (dexamethasone) and subgroup III (phosphate buffered saline, PBS). Corneas were harvested and immunohistochemical staining was performed to compare the extents of neovascularization and CD11b+ cell infiltration. Real-time polymerase chain reaction was performed to quantify the expression of inflammatory cytokines and VEGF-A in the corneas. RESULTS Trapping VEGF-A with aflibercept resulted in significantly decreased angiogenesis and inflammation compared with the dexamethasone and PBS treatments in the dry eye corneas (all P<0.05), but with no such effects in non-dry eyes. The anti-inflammatory and anti-angiogenic effects of VEGF-A trapping were stronger than those of dexamethasone in both dry eye and non-dry eye corneas (all P<0.05). The levels of RNA expression of VEGF-A, TNF-alpha, and IL-6 in the aflibercept subgroup were significantly decreased compared with those in the PBS subgroup in the dry eye group. CONCLUSION Compared with non-dry eye corneas, dry eye corneas have greater amounts of inflammation and neovascularization and also have a more robust response to anti-inflammatory and anti-angiogenic agents after ocular surface surgery. Trapping VEGF-A is effective in decreasing both angiogenesis and inflammation in dry eye corneas after ocular surface surgery. PMID:27990354

  20. Feeder-free differentiation of cells exhibiting characteristics of corneal endothelium from human induced pluripotent stem cells.

    PubMed

    Wagoner, Michael D; Bohrer, Laura R; Aldrich, Benjamin T; Greiner, Mark A; Mullins, Robert F; Worthington, Kristan S; Tucker, Budd A; Wiley, Luke A

    2018-05-08

    The purpose of this study was to devise a strategy for the derivation of corneal endothelial cells (CEnCs) from adult fibroblast-derived induced pluripotent stem cells (iPSCs). IPSCs were generated from an adult human with normal ocular history via expression of OCT4 , SOX2 , KLF4 and c-MYC Neural crest cells (NCCs) were differentiated from iPSCs via addition of CHIR99021 and SB4315542. NCCs were driven toward a CEnC fate via addition of B27, PDGF-BB and DKK-2 to CEnC media. Differentiation of NCCs and CEnCs was evaluated via rt-PCR, morphological and immunocytochemical analysis. At 17 days post-NCC induction, there were notable changes in cell morphology and upregulation of the neural crest lineage transcripts PAX3 , SOX9 , TFAP2A , SOX10 and p75NTR and the proteins p75/NGFR and SOX10. Exposure of NCCs to B27, PDGF-BB and DKK-2 induced a shift in morphology from a spindle-shaped neural phenotype to a tightly-packed hexagonal appearance and increased expression of the transcripts ATP1A1 , COL8A1 , COL8A2 , AQP1 and CDH2 and the proteins ZO-1, N-Cad, AQP-1 and Na + /K + ATPase. Replacement of NCC media with CEnC media on day 3, 5 or 8 reduced the differentiation time needed to yield CEnCs. IPSC-derived CEnCs could be used for evaluation of cornea endothelial disease pathophysiology and for testing of novel therapeutics. © 2018. Published by The Company of Biologists Ltd.

Top