Sample records for upgrading radiological work

  1. Benign Papillomas Without Atypia Diagnosed on Core Needle Biopsy: Experience From a Single Institution and Proposed Criteria for Excision

    PubMed Central

    Nayak, Anupma; Carkaci, Selin; Gilcrease, Michael Z.; Liu, Ping; Middleton, Lavinia P.; Bassett, Roland L.; Zhang, Jinxia; Zhang, Hong; Coyne, Robin L.; Bevers, Therese B.; Sneige, Nour; Huo, Lei

    2015-01-01

    The management of benign papilloma (BP) without atypia identified on breast core needle biopsy (CNB) is controversial. We describe the clinicopathologic features of 80 patients with such lesions in our institution, with an upgrade rate to malignancy of 3.8%. A multidisciplinary approach to select patients for surgical excision is recommended. Background The management of benign papilloma (BP) without atypia identified on breast core needle biopsy (CNB) is controversial. In this study, we determined the upgrade rate to malignancy for BPs without atypia diagnosed on CNB and whether there are factors associated with upgrade. Methods Through our pathology database search, we studied 80 BPs without atypia identified on CNB from 80 patients from 1997 to 2010, including 30 lesions that had undergone excision and 50 lesions that had undergone ≥ 2 years of radiologic follow-up. Associations between surgery or upgrade to malignancy and clinical, radiologic, and pathologic features were analyzed. Results Mass lesions, lesions sampled by ultrasound-guided CNB, and palpable lesions were associated with surgical excision. All 3 upgraded cases were mass lesions sampled by ultrasound-guided CNB. None of the lesions with radiologic follow-up only were upgraded to malignancy. The overall upgrade rate was 3.8%. None of the clinical, radiologic, or histologic features were predictive of upgrade. Conclusion Because the majority of patients can be safely managed with radiologic surveillance, a selective approach for surgical excision is recommended. Our proposed criteria for excision include pathologic/radiologic discordance or sampling by ultrasound-guided CNB without vacuum assistance when the patient is symptomatic or lesion size is ≥ 1.5 cm. PMID:24119786

  2. Breast intraductal papillomas without atypia in radiologic-pathologic concordant core-needle biopsies: Rate of upgrade to carcinoma at excision.

    PubMed

    Pareja, Fresia; Corben, Adriana D; Brennan, Sandra B; Murray, Melissa P; Bowser, Zenica L; Jakate, Kiran; Sebastiano, Christopher; Morrow, Monica; Morris, Elizabeth A; Brogi, Edi

    2016-09-15

    The surgical management of mammary intraductal papilloma without atypia (IDP) identified at core-needle biopsy (CNB) is controversial. This study assessed the rate of upgrade to carcinoma at surgical excision (EXC). This study identified women with a CNB diagnosis of intraductal papilloma without atypia or carcinoma at a cancer center between 2003 and 2013. Radiologic-pathologic concordance was assessed for all cases, and discordant cases were excluded. The radiologic and clinicopathologic features of patients with a CNB diagnosis of IDP were correlated with an upgrade to carcinoma at EXC. The study population consists of 189 women with 196 IDPs; 166 women (171 IDPs) underwent EXC. The upgrade rate was 2.3% (4 of 171). The upgraded lesions were 2 invasive lobular carcinomas and 2 cases of ductal carcinoma in situ (DCIS). One case of DCIS involved the residual IDP, whereas the other 3 carcinomas were ≥ 8 mm away. Twenty-four women (25 IDPs) did not undergo EXC and had stable imaging on follow-up (median, 23.5 months). The upgrade rate at EXC for IDPs diagnosed at CNB with radiologic-pathologic concordance was 2.3%. These findings suggest that observation is appropriate for patients with radiologic-pathologic concordant CNB yielding IDP, regardless of its size. Cancer 2016. © 2016 American Cancer Society. Cancer 2016;122:2819-2827. © 2016 American Cancer Society. © 2016 American Cancer Society.

  3. LATIN AMERICAN AND CARIBBEAN WORKSHOP ON THE SUSTAINABILITY OF RADIOACTIVE SOURCE PHYSICAL PROTECTION UPGRADES HOSTED IN GUATEMALA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greenberg, Raymond; Watson, Erica E.; Morris, Frederic A.

    2009-10-07

    The Global Threat Reduction Initiative (GTRI) reduces and protects vulnerable nuclear and radiological material located at civilian sites worldwide. The GTRI program has worked successfully to remove and protect nuclear and radioactive materials, including orphaned and disused high-activity sources, and is now working to ensure sustainability. Internationally, over 40 countries are cooperating with GTRI to enhance the security of radiological materials. GTRI is now seeking to develop and enhance sustainability by coordinating its resources with those of the partner country, other donor countries, and international organizations such as the International Atomic Energy Agency (IAEA).

  4. Induced activation studies for the LHC upgrade to High Luminosity LHC

    NASA Astrophysics Data System (ADS)

    Adorisio, C.; Roesler, S.

    2018-06-01

    The Large Hadron Collider (LHC) will be upgraded in 2019/2020 to increase its luminosity (rate of collisions) by a factor of five beyond its design value and the integrated luminosity by a factor ten, in order to maintain scientific progress and exploit its full capacity. The novel machine configuration, called High Luminosity LHC (HL-LHC), will increase consequently the level of activation of its components. The evaluation of the radiological impact of the HL-LHC operation in the Long Straight Sections of the Insertion Region 1 (ATLAS) and Insertion Region 5 (CMS) is presented. Using the Monte Carlo code FLUKA, ambient dose equivalent rate estimations have been performed on the basis of two announced operating scenarios and using the latest available machine layout. The HL-LHC project requires new technical infrastructure with caverns and 300 m long tunnels along the Insertion Regions 1 and 5. The new underground service galleries will be accessible during the operation of the accelerator machine. The radiological risk assessment for the Civil Engineering work foreseen to start excavating the new galleries in the next LHC Long Shutdown and the radiological impact of the machine operation will be discussed.

  5. Benign Intraductal Papilloma without Atypia on Core Needle Biopsy Has a Low Rate of Upgrading to Malignancy after Excision.

    PubMed

    Han, Song-Hee; Kim, Milim; Chung, Yul Ri; Yun, Bo La; Jang, Mijung; Kim, Sun Mi; Kang, Eunyoung; Kim, Eun-Kyu; Park, So Yeon

    2018-03-01

    The management of benign intraductal papilloma (IDP) without atypia diagnosed on core needle biopsy (CNB) remains controversial. This study was performed to evaluate the rate of upgrading to malignancy or high-risk lesions after excision and to identify factors associated with upgrading using a large series of benign IDP cases without atypia. We included patients who were diagnosed as having benign IDP without atypia on CNB and underwent surgical or vacuum-assisted excision between 2010 and 2015. We analyzed the clinical, radiologic, and histopathologic features of IDPs that were upgraded to malignancy or high-risk lesions after excision. A total of 511 benign IDPs without atypia diagnosed via CNB were identified, of which 398 cases were treated with excision. After reviewing these cases, four cases of high-risk lesions in adjacent tissue on CNB, two cases which were revealed as papilloma with atypia, and nine cases of malignancy in the same breast were excluded. In the remaining 383 cases, the rate of upgrading to malignancy and high-risk lesions after excision was 0.8% and 4.4%, respectively. The presence of concurrent contralateral breast cancer, the presence of symptoms, and multifocality were factors significantly associated with upgrading to malignancy on subsequent excision. Surgical excision rather than vacuum-assisted excision was significantly associated with upgrading to high-risk lesions or malignancy. The rate of upgrading to malignancy for benign IDP without atypia was very low, suggesting that close clinical and radiologic observation may be sufficient for patients with benign IDP without atypia on CNB under proper settings.

  6. Benign Intraductal Papilloma without Atypia on Core Needle Biopsy Has a Low Rate of Upgrading to Malignancy after Excision

    PubMed Central

    Han, Song-Hee; Kim, Milim; Chung, Yul Ri; Yun, Bo La; Jang, Mijung; Kim, Sun Mi; Kang, Eunyoung; Kim, Eun-Kyu

    2018-01-01

    Purpose The management of benign intraductal papilloma (IDP) without atypia diagnosed on core needle biopsy (CNB) remains controversial. This study was performed to evaluate the rate of upgrading to malignancy or high-risk lesions after excision and to identify factors associated with upgrading using a large series of benign IDP cases without atypia. Methods We included patients who were diagnosed as having benign IDP without atypia on CNB and underwent surgical or vacuum-assisted excision between 2010 and 2015. We analyzed the clinical, radiologic, and histopathologic features of IDPs that were upgraded to malignancy or high-risk lesions after excision. Results A total of 511 benign IDPs without atypia diagnosed via CNB were identified, of which 398 cases were treated with excision. After reviewing these cases, four cases of high-risk lesions in adjacent tissue on CNB, two cases which were revealed as papilloma with atypia, and nine cases of malignancy in the same breast were excluded. In the remaining 383 cases, the rate of upgrading to malignancy and high-risk lesions after excision was 0.8% and 4.4%, respectively. The presence of concurrent contralateral breast cancer, the presence of symptoms, and multifocality were factors significantly associated with upgrading to malignancy on subsequent excision. Surgical excision rather than vacuum-assisted excision was significantly associated with upgrading to high-risk lesions or malignancy. Conclusion The rate of upgrading to malignancy for benign IDP without atypia was very low, suggesting that close clinical and radiologic observation may be sufficient for patients with benign IDP without atypia on CNB under proper settings. PMID:29628987

  7. Evaluation of radiological dispersion/consequence codes supporting DOE nuclear facility SARs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O`Kula, K.R.; Paik, I.K.; Chung, D.Y.

    1996-12-31

    Since the early 1990s, the authorization basis documentation of many U.S. Department of Energy (DOE) nuclear facilities has been upgraded to comply with DOE orders and standards. In this process, many safety analyses have been revised. Unfortunately, there has been nonuniform application of software, and the most appropriate computer and engineering methodologies often are not applied. A DOE Accident Phenomenology and Consequence (APAC) Methodology Evaluation Program was originated at the request of DOE Defense Programs to evaluate the safety analysis methodologies used in nuclear facility authorization basis documentation and to define future cost-effective support and development initiatives. Six areas, includingmore » source term development (fire, spills, and explosion analysis), in-facility transport, and dispersion/ consequence analysis (chemical and radiological) are contained in the APAC program. The evaluation process, codes considered, key results, and recommendations for future model and software development of the Radiological Dispersion/Consequence Working Group are summarized in this paper.« less

  8. U.S.-CHINA RADIOLOGICAL SOURCE SECURITY PROJECT: CONTINUING AND EXPANDING BILATERAL COOPERATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Zhixuan; Zhou, Qifu; Yang, Yaoyun

    2009-10-07

    The successful radiological security cooperation between the U.S. and China to secure at-risk sites near venues of the 2008 Beijing Summer Olympics has led to an expanded bilateral nonproliferation cooperation scope. The U.S. Department of Energy’s National Nuclear Security Administration, the Chinese Atomic Energy Authority and the China Ministry of Environmental Protection are continuing joint efforts to secure radiological sources throughout China under the U.S.-China Peaceful Uses of Nuclear Technology (PUNT) Agreement. Joint cooperation activities include physical security upgrades of sites with International Atomic Energy Agency (IAEA) Category 1 radiological sources, packaging, recovery, and storage of high activity transuranic andmore » beta gamma sources, and secure transportation practices for the movement of recovered sources. Expansion of cooperation into numerous provinces within China includes the use of integrated training workshops that will demonstrate methodologies and best practices between U.S. and Chinese radiological source security and recovery experts. The fiscal year 2009 expanded scope of cooperation will be conducted similar to the 2008 Olympic cooperation with the Global Threat Reduction Initiative taking the lead for the U.S., PUNT being the umbrella agreement, and Los Alamos, Sandia, and Oak Ridge National Laboratories operating as technical working groups. This paper outlines the accomplishments of the joint implementation and training efforts to date and discusses the possible impact on future U.S./China cooperation.« less

  9. Upgrading of Sergiev Posad department of Moscow NPO Radon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debieve, Pierre; Delecaut, Gregory; Vanleeuw, Daniel

    Available in abstract form only. Full text of publication follows: BELGATOM and IRE Consortium has been awarded by the European Commission end of 2005 to conduct a project entitled 'Upgrading of Sergiev Posad Department of Moscow NPO Radon and the assessment of the radiological impact in the area nearby'. The main aims to achieve in the frame of this Europe-aid Project are: - Improvement of the performance and the safety level of the present radwaste management system, taking into account the additional waste expected from the Kurchatov Institute rehabilitation and from the forecast decommissioning of Research Reactors on the territorymore » of Moscow. - Basic design and assistance for the procurement of upgrading equipment related to: - radwaste sorting and pretreatment - replacement of the hydraulic system of the existing super-compactor - characterisation system for radwaste 'Support for preparing the PSAR and PEIAR for new licensing' Assessment of the radiological impact in an area of 50 km radius around Sergiev Posad Department. - The initial duration of this Project is 3 years, starting beginning of 2006. This paper describes the difficulties encountered to start and implement the Project and its status at the half of the planned time schedule. (authors)« less

  10. REVIEW OF THE RADNET AIR MONITORING NETWORK UPGRADE AND EXPANSION

    EPA Science Inventory

    RadNet, formerly known as ERAMS, has been operating since the 1970's, monitoring environmental radiation across the country, supporting responses to radiological emergencies, and providing important information on background levels of radiation in the environment. The original ...

  11. Telemedicine and pediatric radiology: a new environment for training, learning, and interactive discussions.

    PubMed

    Monteiro, Alexandra M V; Corrêa, Diogo Goulart; Santos, Alair Augusto Sarmet M D; Cavalcanti, Silvio A; Sakuno, Telma; Filgueiras, Tereza; Just, Eduardo; Santos, Munique; Messina, Luiz Ary; Haddad, Ana Estela; Marchiori, Edson

    2011-12-01

    To report the experience of the Brazilian Program of Pediatric Teleradiology in combining teleconferencing and a virtual learning environment for services integration, collaborative research, and continuing education in pediatric radiology. We performed virtual meetings from March 2005 to October 2010 on pediatric radiology-related themes, using a combination of videoconferences and Web conferences, which were recorded and made available in an open-source software (Moodle) for reuse. We performed 58 virtual sessions: 29 anatomical-clinical-radiological sessions, 28 on upgrading themes, and 1 virtual symposium. The average of connected points was 12 by videoconference and 39 by Web conference, and of 450 participants per event. At the time of this writing, 318 physicians and students are registered in the virtual learning environment, with a total of 14,678 accesses. Telemedicine is being included in pediatric radiology practice, as a means for distance education, training, and continuing integration between groups.

  12. Impact assessment of ionizing radiation on human and non-human biota from the vicinity of a near-surface radioactive waste repository.

    PubMed

    Nedveckaite, T; Gudelis, A; Vives i Batlle, J

    2013-05-01

    This work describes the radiological assessment of the near-surface Maisiagala radioactive waste repository (Lithuania) over the period 2005-2012, with focus on water pathways and special emphasis on tritium. The study includes an assessment of the effect of post-closure upgrading, the durability of which is greater than 30 years. Both human and terrestrial non-human biota are considered, with local low-intensity forestry and small farms being the area of concern. The radiological exposure was evaluated using the RESRAD-OFFSITE, RESRAD-BIOTA and ERICA codes in combination with long-term data from a dedicated environmental monitoring programme. All measurements were performed at the Lithuanian Institute of Physics as part of this project. It is determined that, after repository upgrading, radiological exposure to humans are significantly lower than the human dose constraint of 0.2 mSv/year valid in the Republic of Lithuania. Likewise, for non-human biota, dose rates are below the ERICA/PROTECT screening levels. The potential annual effective inhalation dose that could be incurred by the highest-exposed human individual (which is due to tritiated water vapour airborne release over the most exposed area) does not exceed 0.1 μSv. Tritium-labelled drinking water appears to be the main pathway for human impact, representing about 83 % of the exposure. Annual committed effective dose (CED) values for members of the public consuming birch sap as medical practice are calculated to be several orders of magnitude below the CEDs for the same location associated with drinking of well water. The data presented here indicate that upper soil-layer samples may not provide a good indication of potential exposure to terrestrial deep-rooted trees, as demonstrated by an investigation of stratified (3)H in soil moisture, expressed on a wet soil mass basis, in an area with subsurface contamination.

  13. Flat panel detectors--closing the (digital) gap in chest and skeletal radiology.

    PubMed

    Reiff, K J

    1999-08-01

    In the radiological department today the majority of all X-ray procedures on chest and skeletal radiography is performed with classical film-screen-systems. Using digital luminescence radiography (DLR or CR, which stands for Computed Radiography) as a technique has shown a way to replace this 100-year-old procedure of doing general radiography work by acquiring the X-rays digitally via phosphor screens, but this approach has faced criticism from lots of radiologists world wide and therefore has not been widely accepted except in the intensive care environment. A new technology is now rising based on the use of so called flat panel X-ray (FD) detectors. Semi-conducting material detects the X-rays in digital form directly and creates an instantaneous image for display, distribution and diagnosis. This ability combined with a large field of view and compared to existing methods--excellent detective quantum efficiency represents a revolutionary step for chest and skeletal radiography and will put basic X-ray-work back into the focus of radiological solutions. This paper will explain the basic technology of flat panel detectors, possible system solutions based on this new technology, aspects of the user interface influencing the system utilization and versatility as well as the possibility to redefine the patient examination process for chest and skeletal radiography. Furthermore the author discusses limitations for the first released systems, upgrades for the installed base and possible scenarios for the future, e.g. fluoroscopy or angiography application.

  14. All pure flat atypical atypia lesions of the breast diagnosed using percutaneous vacuum-assisted breast biopsy do not need surgical excision.

    PubMed

    Ouldamer, Lobna; Poisson, Elodie; Arbion, Flavie; Bonneau, Carole; Vildé, Anne; Body, Gilles; Michenet, Patrick

    2018-04-14

    The purposes of this study were to evaluate the outcome of women with pure flat atypical atypia (FEA) diagnosed at vacuum-assisted breast biopsy (VABB) targeting microcalcifications and to determine whether clinical, radiological and pathologic parameters are able to predict which lesions will be upgraded to malignancy. 2414 cases of consecutive VABB for microcalcifications using VA 8-, 10- or 11-Gauge stereotactically guided core biopsy performed between January 2005 and December 2011 from two french breast cancer centers were evaluated. Data of women with VABB-diagnosed pure FEA who underwent either excisional surgery or mammographic follow-up were analyzed. Cases with mass lesions or ipsilateral cancers were excluded. Two pathologists (FA,PM) reviewed the results of procedures performed. Clinical, radiological, as well as histological criteria have been studied in order to determine the correlation between these factors and carcinoma underestimation. This study included 70 cases of pure FEA. Twenty women underwent surgical excision and 50 had clinical and mammographic surveillance only. In three women FEA was upgraded to breast cancer on excision. Clinical and mammographic follow-up for a mean of 56 months ± 27 in the group without excision showed two cancers in the same breast (Intermediate grade DCIS, and invasive ductal carcinoma 84 and 48 months respectively after VABB). Three factors were significantly predictive of underestimation or occurence of cancer for pure FEA when the radiologic lesions are calcifications: age≥ 57 years, radiologic size >10 mm and number of FEA foci ≥4. Copyright © 2018. Published by Elsevier Ltd.

  15. Intercampus network of the Department of Radiology, School of Medicine, Indiana University

    NASA Astrophysics Data System (ADS)

    Witt, Robert M.; Gibbs, Thomas; Holden, Robert W.

    1994-05-01

    During the past year, the Department of Radiology, School of Medicine, Indiana University designed, specified, and installed a campus wide network. The network supports three functions: a laser camera network to allow the transfer of hard copy images across the campus; a positron emission tomography (PET) network to allow the interconnection of the workstations comprising the PET system; and a future personal computer network to allow support of departmental administrative functions with an upgrade path to allow the display of soft copy images in physician offices and other locations in the department.

  16. Upgrades of DARWIN, a dose and spectrum monitoring system applicable to various types of radiation over wide energy ranges

    NASA Astrophysics Data System (ADS)

    Sato, Tatsuhiko; Satoh, Daiki; Endo, Akira; Shigyo, Nobuhiro; Watanabe, Fusao; Sakurai, Hiroki; Arai, Yoichi

    2011-05-01

    A dose and spectrum monitoring system applicable to neutrons, photons and muons over wide ranges of energy, designated as DARWIN, has been developed for radiological protection in high-energy accelerator facilities. DARWIN consists of a phoswitch-type scintillation detector, a data-acquisition (DAQ) module for digital waveform analysis, and a personal computer equipped with a graphical-user-interface (GUI) program for controlling the system. The system was recently upgraded by introducing an original DAQ module based on a field programmable gate array, FPGA, and also by adding a function for estimating neutron and photon spectra based on an unfolding technique without requiring any specific scientific background of the user. The performance of the upgraded DARWIN was examined in various radiation fields, including an operational field in J-PARC. The experiments revealed that the dose rates and spectra measured by the upgraded DARWIN are quite reasonable, even in radiation fields with peak structures in terms of both spectrum and time variation. These results clearly demonstrate the usefulness of DARWIN for improving radiation safety in high-energy accelerator facilities.

  17. Majority of flat epithelial atypia diagnosed on biopsy do not require surgical excision.

    PubMed

    Chan, Patrick Mun Yew; Chotai, Niketa; Lai, Eileen Shujuan; Sin, Pei Yi; Chen, Juliana; Lu, Sarah Qinghui; Goh, Mui Heng; Chong, Bee Kiang; Ho, Bernard Chi Shern; Tan, Ern Yu

    2018-02-01

    Borderline risk lesions such as flat epithelial atypia (FEA) are increasingly being diagnosed on biopsy. The need for surgery is being debated. In this study, we determined the frequency of histological upgrade following a diagnosis of FEA on biopsy and evaluated potential predictive factors. Retrospective review was done of 194 women who underwent biopsy of indeterminate lesions (total 195 lesions) that were diagnosed as FEA. The review covered a 10-year period. Cases where malignancy was also present together with FEA within the same biopsy cores were excluded. Lesions diagnosed as FEA on biopsy were mostly asymptomatic and presented as microcalcifications on mammogram. Flat epithelial atypia was the only abnormality detected in one-third of cases, was associated with a benign or another borderline lesion in another third and was associated with atypical ductal hyperplasia (ADH) in another third. Six patients (3.1%) were later found to have ductal carcinoma-in-situ (DCIS) at surgery. The presence of ADH in the biopsy was the only predictor of histological upgrade to malignancy (P = 0.04, OR 11.24, 95% CI 1.10 - 115.10), and was present in 5 of the 6 patients. Surgery was advised in the last patient because of radiology-pathology discordance. Thirty-six lesions (18.5%) were not excised and no interval progression or malignancy was found on follow up. Histological upgrade to malignancy was uncommon in lesions found on biopsy to be FEA. Non-operative management of biopsy-proven FEA can be considered in the absence of ADH and radiology-pathology discordance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Rates of upgrade to malignancy for 271 cases of flat epithelial atypia (FEA) diagnosed by breast core biopsy.

    PubMed

    Peres, Alexandre; Barranger, Emmanuel; Becette, Véronique; Boudinet, Alain; Guinebretiere, Jean-Marc; Cherel, Pascal

    2012-06-01

    Flat epithelial atypia (FEA) is a borderline lesion that might represent an early stage in the development of certain low-grade carcinomas in situ and invasive cancers. There are no guidelines on its management. Our objectives were to determine the upgrade to malignancy rate and identify a subpopulation of patients that might undergo just mammographic surveillance. We retrospectively reviewed the data for 271 FEA cases among 5,555 breast core biopsies obtained over a 7-year period (January 2003-2010). We collated clinical data (age, history of cancer, menopausal status), radiological data (lesion type, size, Bi-Rads category), technical data (number of biopsies, needle gauge, excision quality) and histological data and sought correlations between these factors and upgrade rate. The 271 FEA comprised 128 cases of pure FEA, 135 cases of FEA + atypical ductal hyperplasia, and 8 cases of FEA + atypical lobular hyperplasia. Overall, 184 patients underwent surgery and 46 mammographic surveillance. Surgery detected 34 cases of malignancy (23 CIS, 7 invasive cancers, and 4 mixed cases) giving a 15% upgrade rate. Quality of excision was the only factor associated with under-diagnosis. The presence of FEA at biopsy warrants surgery.

  19. Utilization of the High Flux Isotope Reactor at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selby, Douglas L; Bilheux, Hassina Z; Meilleur, Flora

    2015-01-01

    This paper addresses several aspects of the scientific utilization of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). Topics to be covered will include: 1) HFIR neutron scattering instruments and the formal instrument user program; 2) Recent upgrades to the neutron scattering instrument stations at the reactor, and 3) eMod a new tool for addressing instrument modifications and providing configuration control and design process for scientific instruments at HFIR and the Spallation Neutron Source (SNS). There are 15 operating neutron instrument stations at HFIR with 12 of them organized into a formal user program. Since the last presentationmore » on HFIR instruments at IGORR we have installed a Single Crystal Quasi-Laue Diffractometer instrument called IMAGINE; and we have made significant upgrades to HFIR neutron scattering instruments including the Cold Triple Axis Instrument, the Wide Angle Neutron Diffractometer, the Powder Diffractometer, and the Neutron Imaging station. In addition, we have initiated upgrades to the Thermal Triple Axis Instrument and the Bio-SANS cold neutron instrument detector system. All of these upgrades are tied to a continuous effort to maintain a high level neutron scattering user program at the HFIR. For the purpose of tracking modifications such as those mentioned and configuration control we have been developing an electronic system for entering instrument modification requests that follows a modification or instrument project through concept development, design, fabrication, installation, and commissioning. This system, which we call eMod, electronically leads the task leader through a series of questions and checklists that then identifies such things as ES&H and radiological issues and then automatically designates specific individuals for the activity review process. The system has been in use for less than a year and we are still working out some of the inefficiencies, but we believe that this will become a very effective tool for achieving the configuration and process control believed to be necessary for scientific instrument systems.« less

  20. Radiological Threat Reduction (RTR) program : implementing physical security to protect large radioactive sources worldwide.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowe, Daniel L.

    2004-11-01

    The U.S. Department of Energy's Radiological Threat Reduction (RTR) Program strives to reduce the threat of a Radiological Dispersion Device (RDD) incident that could affect U.S. interests worldwide. Sandia National Laboratories supports the RTR program on many different levels. Sandia works directly with DOE to develop strategies, including the selection of countries to receive support and the identification of radioactive materials to be protected. Sandia also works with DOE in the development of guidelines and in training DOE project managers in physical protection principles. Other support to DOE includes performing rapid assessments and providing guidance for establishing foreign regulatory andmore » knowledge infrastructure. Sandia works directly with foreign governments to establish cooperative agreements necessary to implement the RTR Program efforts to protect radioactive sources. Once necessary agreements are in place, Sandia works with in-country organizations to implement various security related initiatives, such as installing security systems and searching for (and securing) orphaned radioactive sources. The radioactive materials of interest to the RTR program include Cobalt 60, Cesium 137, Strontium 90, Iridium 192, Radium 226, Plutonium 238, Americium 241, Californium 252, and Others. Security systems are implemented using a standardized approach that provides consistency through out the RTR program efforts at Sandia. The approach incorporates a series of major tasks that overlap in order to provide continuity. The major task sequence is to: Establish in-country contacts - integrators, Obtain material characterizations, Perform site assessments and vulnerability assessments, Develop upgrade plans, Procure and install equipment, Conduct acceptance testing and performance testing, Develop procedures, and Conduct training. Other tasks are incorporated as appropriate and commonly include such as support of reconfiguring infrastructure, and developing security plans, etc. This standardized approach is applied to specific country and regional needs. Recent examples (FY 2003-2004) include foreign missions to Lithuania, Russian Federation Navy, Russia - PNPI, Greece (joint mission with IAEA), Tanzania, Iraq, Chile, Ecuador, and Egypt. Some of the ambitions and results of the RTR program may be characterized by the successes in Lithuania, Greece, and Russia.« less

  1. Upgrade of ductal carcinoma in situ on core biopsies to invasive disease at final surgery: a retrospective review across the Scottish Breast Screening Programme.

    PubMed

    Sim, Y T; Litherland, J; Lindsay, E; Hendry, P; Brauer, K; Dobson, H; Cordiner, C; Gagliardi, T; Smart, L

    2015-05-01

    To identify factors affecting upgrade rates from B5a (non-invasive) preoperative core biopsies to invasive disease at surgery and ways to improve screening performance. This was a retrospective analysis of 1252 cases of B5a biopsies across all six Scottish Breast Screening Programmes (BSPs), ranging between 2004 and 2012. Final surgical histopathology was correlated with radiological and biopsy factors. Data were analysed using basic Microsoft Excel and standard Chi-squared test used for evaluating statistical significance. B5a upgrade rates for the units ranged from 19.2% to 29.2%, with an average of 23.6%. Mean sizes of invasive tumours were small (3-11 mm). The upgrade rate was significantly higher for cases where the main mammographic abnormality was mass, distortion, or asymmetry, compared with micro-calcification alone (33.2% versus 21.7%, p = 0.0004). The upgrade rate was significantly lower with the use of large-volume vacuum-assisted biopsy (VAB) devices than 14 G core needles (19.9% versus 26%, p = 0.013); in stereotactic than ultrasound-guided biopsies (21.2% versus 36.1%, p < 0.001). Heterogeneity of data from different centres limited evaluation of other potential factors. Upgrade rates are lower for cases with micro-calcification as the sole mammographic feature with the use of VAB devices. Nevertheless, there is variation in practice across Scottish BSPs, including first-line biopsy technique and/or device; and it is of interest that a few centres maintain low upgrade rates despite not using VAB routinely for biopsy of micro-calcification. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  2. Renewal of radiological equipment.

    PubMed

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a minimum of 5 years, with annual updating.

  3. Liquid Scintillation Counting - Packard Triple-Label Calibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torretto, P. A.

    2017-03-23

    The Radiological Measurements Laboratory (RML) maintains and operates nine Packard Liquid Scintillation Counters (LSCs). These counters were obtained through various sources and were generally purchased as 2500, 2700 or 3100 series counters. In 2004/2005 the software and firmware on the counters were upgraded. The counters are now designated as 3100 series counters running the Quantasmart software package. Thus, a single procedure can be used to calibrate and operate the Packard LSCs.

  4. Radiological Worker II Training, Course 20301 (Live), Course 12909 (Test)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, Jimmy D.

    Radiological worker training is the basic building block for any additional radiological training you may receive. Upon completing radiological worker training, you will have the basic knowledge needed to work safely, using proper radiological practices, in areas where radiological hazards exist. You will also have a better understanding of the hazards and responsibilities associated with radiological work to help prevent the carelessness that can occur when working continually with or around radioactive material. This course does not qualify you for any specific radiological work. You may be required to take additional training at individual facilities to address facility- and job-specificmore » hazards and procedures.« less

  5. PACS technologies and reliability: are we making things better or worse?

    NASA Astrophysics Data System (ADS)

    Horii, Steven C.; Redfern, Regina O.; Kundel, Harold L.; Nodine, Calvin F.

    2002-05-01

    In the process of installing picture archiving and communications (PACS) and speech recognition equipment, upgrading it, and working with previously stored digital image information, the authors encountered a number of problems. Examination of these difficulties illustrated the complex nature of our existing systems and how difficult it is, in many cases, to predict the behavior of these systems. This was found to be true even for our relatively small number of interconnected systems. The purpose of this paper is to illustrate some of the principles of understanding complex system interaction through examples from our experience. The work for this paper grew out of a number of studies we had carried out on our PACS over several years. The complex nature of our systems was evaluated through comparison of our operations with known examples of systems in other industries. Three scenarios: a network failure, a system software upgrade, and attempting to read media from an old archive showed that the major systems used in the radiology departments of many healthcare facilities (HIS, RIS, PACS, and speed recognition) are likely to interact in complex and often unpredictable ways. These interactions may be very difficult or impossible to predict, so that some plans should be made to overcome the negative aspects of the problems that result. Failures and problems, often unpredictable ones, are a likely side effect of having multiple information handling and processing systems interconnected and interoperating. Planning to avoid, or at least not be so vulnerable, to such difficulties is an important aspect of systems planning.

  6. Audience response techniques for 21st century radiology education.

    PubMed

    Richardson, Michael L

    2014-07-01

    Audience response system (ARS) provides an excellent tool for improving interactive learning in radiology residents. However, it is not the technology but the pedagogy that matters the most. It is long past time to upgrade our ARS teaching techniques to match our ARS technology. In this article, several problems with current usage of ARS are discussed and several prescriptions for improving this are presented. Simplifying the ease of use of ARS will get this useful technology into more hands. Using ARS in a bidirectional manner will give us an even better idea of how and what our students are learning. Asking questions on the fly will obviate the usual tedium of multiple-choice questions and allow us to quiz our students in a much more natural manner. It is time to move on to more innovative ARS techniques that are well adapted to radiology and its different styles of learning. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  7. Upgrade/Renovate Clinic Project at Ellsworth Air Force Base, South Dakota Generally Complied with the American Recovery and Reinvestment Act

    DTIC Science & Technology

    2011-01-06

    extended to the staff. Please direct questions to Mr. Michael Joseph at (757) 872-4698. Alice F. Carey Assistant Inspector General Readiness...optometry, dental , flight medicine, mental health, physical therapy, laboratory, pharmacy, and radiology. 3 Project Support Personnel at USACE...plan, dental equipment revisions, a corridor addition, replacement of all basement piping, and $3,374,672 of Operations and Maintenance funds

  8. A web implementation: the good and the not-so-good.

    PubMed

    Bergsneider, C; Piraino, D; Fuerst, M

    2001-06-01

    E-commerce, e-mail, e-greeting, e-this, and e-that everywhere you turn there is a new "e" word for an internet or Web application. We, at the Cleveland Clinic Foundation, have been "e-nlightened" and will discuss in this report the implementation of a web-based radiology information system (RIS) in our radiology division or "e-radiology" division. The application, IDXRad Version 10.0 from IDX Corp, Burlington, VT, is in use at the Cleveland Clinic Foundation and has both intranet (for use in Radiology) and internet (referring physician viewing) modules. We will concentrate on the features of using a web browser for the application's front-end, including easy prototyping for screen review, easier mock-ups of demonstrations by vendors and developers, and easier training as more people become web-addicted. Project communication can be facilitated with an internal project web page, and use of the web browser can accommodate quicker turnaround of software upgrades as the software code is centrally located. Compared with other technologies, including client/server, there is a smaller roll out cost when using a standard web browser. However, the new technology requires a change and changes are never implemented without challenges. A seasoned technologist using a legacy system can enter data quicker using function keys than using a graphical user interface and pointing and clicking through a series of pop-up windows. Also, effective use of a web browser depends on intuitive design for it to be easily implemented and accepted by the user. Some software packages will not work on both of the popular web browsers and then are tailored to specific release levels. As computer-based patient records become a standard, patient confidentiality must be enforced. The technical design and application security features that support the web-based software package will be discussed. Also web technologies have their own implementation issues.

  9. [The Mexican Institute of Social Security Institute (IMSS) in Numbers. Functional inventory of imaging medical equipment, 2003].

    PubMed

    2005-01-01

    Medical technology is a fundamental instrument for the provision of health services in the Mexican Institute of Social Security (IMSS) and as a support for diagnostic and therapeutic interventions. The inventory of relevant medical equipment describes the needs for upgrading the technological infrastructure, organize its distribution and plan its renovation in order to guarantee the quality of health services. In this report we describe the type of equipment used in radiology and other imaging services, its geographical distribution, median age in operation and its productivity. The inventory reported 2091 pieces of equipment, ultrasonography and radiology were the most common types (31%) followed by fluoroscopic equipment (20%). Follow-up in the inventory should help in planning the acquisition and maintenance of sophisticated technology used for medical purposes.

  10. 77 FR 19008 - Guidelines for Home Energy Professionals: Standard Work Specifications for Single Family Energy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-29

    ... Professionals: Standard Work Specifications for Single Family Energy Upgrades AGENCY: Office of Energy...: Standard Work Specifications for Single Family Energy Upgrades. This document is a set of work specifications applicable to energy efficiency retrofits of single family homes. These specifications are...

  11. The Management Strategy of Benign Solitary Intraductal Papilloma on Breast Core Biopsy.

    PubMed

    Ko, Dayoung; Kang, Eunyoung; Park, So Yeon; Kim, Sun Mi; Jang, Mijung; Yun, Bo La; Chae, Sumin; Jang, Yerang; Kim, Hye Jin; Kim, Sung-Won; Kim, Eun-Kyu

    2017-08-01

    Intraductal papilloma (IDP) is well-known as one of the common benign breast lesions requiring excision. However, treatment of IDP without atypia is controversial. The aim of our study was to determine the proper management of solitary IDP by core needle biopsy (CNB). We retrospectively reviewed patients with solitary IDP confirmed by CNB from March 2003 to March 2015. We collected data about final pathology after excision, as well as clinical, histologic, and radiologic findings at initial diagnosis. The final pathology was categorized as benign or malignant. We evaluated the rate of upgrade to malignancy and factors associated with malignancy. We identified 405 patients who presented benign solitary IDP by CNB. The mean age was 46.1 years (range, 15-86 years). In total, 135 patients underwent surgical excision, and 211 underwent vacuum-assisted excision. Of 346 patients, malignant lesions were found in 8 patients (2.3%): 7 underwent surgical excision, and 1 underwent vacuum-assisted excision. Only the size of IDP was significantly associated with cancer upgrade (P = .003). Our study shows that overall malignancy upgrade rate of benign solitary IDP after excision is very low (2.3%). Even when the size of IDP was less than 1 cm, the upgrade rate to cancer was only 0.9%. Therefore, for patients with small solitary IDP, we recommend close follow-up with ultrasound instead of excision. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Healthy Indoor Environment Protocols for Home Energy Upgrades

    EPA Pesticide Factsheets

    This page contains the EPA-developed Healthy Indoor Environment Protocols for Home Energy Upgrades, a PDF guide that provides a set of best practices for improving indoor air quality in conjunction with energy upgrade work in homes.

  13. 78 FR 18576 - Guidelines for Home Energy Professionals: Standard Work Specifications for Single Family Energy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-27

    ... Professionals: Standard Work Specifications for Single Family Energy Upgrades AGENCY: Office of Energy... Single Family Energy Upgrades (SWS). This content is a set of recommended work specifications applicable to energy efficiency retrofits of single family homes. These specifications are intended as a...

  14. Nuclear security and radiological preparedness for the olympic games, athens 2004: lessons learned for organizing major public events.

    PubMed

    Kamenopoulou, Vassiliki; Dimitriou, Panayiotis; Hourdakis, Constantine J; Maltezos, Antonios; Matikas, Theodore; Potiriadis, Constantinos; Camarinopoulos, Leonidas

    2006-10-01

    In light of the exceptional circumstances that arose from hosting the Olympic Games in Athens in 2004 and from recent terrorist events internationally, Greece attributes the highest priority to security issues. According to its statutory role, the Greek Atomic Energy Commission is responsible for emergency preparedness and response in case of nuclear and radiological events, and advises the Government on the measures and interventions necessary to protect the public. In this context, the Commission participated in the Nuclear, Radiological, Biological, and Chemical Threat National Emergency Plan, specially developed for the Olympic Games, and coordinated by the Olympic Games Security Division. The objective of this paper is to share the experience gained during the organization of the Olympic Games and to present the nuclear security program implemented prior to, during, and beyond the Games, in order to prevent, detect, assess, and respond to the threat of nuclear terrorism. This program adopted a multi-area coverage of nuclear security, including physical protection of nuclear and radiological facilities, prevention of smuggling of radioactive materials through borders, prevention of dispersion of these materials into the Olympic venues, enhancement of emergency preparedness and response to radiological events, upgrading of the technical infrastructure, establishment of new procedures for assessing the threat and responding to radiological incidents, and training personnel belonging to several organizations involved in the National Emergency Response Plan. Finally, the close cooperation of Greek Authorities with the International Atomic Energy Agency and the U.S. Department of Energy, under the coordination of the Greek Atomic Energy Commission, is also discussed.

  15. Quality index of radiological devices: results of one year of use.

    PubMed

    Tofani, Alessandro; Imbordino, Patrizia; Lecci, Antonio; Bonannini, Claudia; Del Corona, Alberto; Pizzi, Stefano

    2003-01-01

    The physical quality index (QI) of radiological devices summarises in a single numerical value between 0 and 1 the results of constancy tests. The aim of this paper is to illustrate the results of the use of such an index on all public radiological devices in the Livorno province over one year. The quality index was calculated for 82 radiological devices of a wide range of types by implementing its algorithm in a spreadsheet-based software for the automatic handling of quality control data. The distribution of quality index values was computed together with the associated statistical quantities. This distribution is strongly asymmetrical, with a sharp peak near the highest QI values. The mean quality index values for the different types of device show some inhomogeneity: in particular, mammography and panoramic dental radiography devices show far lower quality than other devices. In addition, our analysis has identified the parameters that most frequently do not pass the quality tests for each type of device. Finally, we sought some correlation between quality and age of the device, but this was poorly significant. The quality index proved to be a useful tool providing an overview of the physical conditions of radiological devices. By selecting adequate QI threshold values for, it also helps to decide whether a given device should be upgraded or replaced. The identification of critical parameters for each type of device may be used to improve the definition of the QI by attributing greater weights to critical parameters, so as to better address the maintenance of radiological devices.

  16. Report of the eRHIC Ring-Ring Working Group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aschenauer, E. C.; Berg, S.; Blaskiewicz, M.

    2015-10-13

    This report evaluates the ring-ring option for eRHIC as a lower risk alternative to the linac-ring option. The reduced risk goes along with a reduced initial luminosity performance. However, a luminosity upgrade path is kept open. This upgrade path consists of two branches, with the ultimate upgrade being either a ring-ring or a linac-ring scheme. The linac-ring upgrade could be almost identical to the proposed linac-ring scheme, which is based on an ERL in the RHIC tunnel. This linac-ring version has been studied in great detail over the past ten years, and its significant risks are known. On the othermore » hand, no detailed work on an ultimate performance ring-ring scenario has been performed yet, other than the development of a consistent parameter set. Pursuing the ring-ring upgrade path introduces high risks and requires significant design work that is beyond the scope of this report.« less

  17. RCT: Module 2.11, Radiological Work Coverage, Course 8777

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillmer, Kurt T.

    2017-07-20

    Radiological work is usually approved and controlled by radiation protection personnel by using administrative and procedural controls, such as radiological work permits (RWPs). In addition, some jobs will require working in, or will have the potential for creating, very high radiation, contamination, or airborne radioactivity areas. Radiological control technicians (RCTs) providing job coverage have an integral role in controlling radiological hazards. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

  18. Web Implementation of Quality Assurance (QA) for X-ray Units in Balkanic Medical Institutions.

    PubMed

    Urošević, Vlade; Ristić, Olga; Milošević, Danijela; Košutić, Duško

    2015-08-01

    Diagnostic radiology is the major contributor to the total dose of the population from all artificial sources. In order to reduce radiation exposure and optimize diagnostic x-ray image quality, it is necessary to increase the quality and efficiency of quality assurance (QA) and audit programs. This work presents a web application providing completely new QA solutions for x-ray modalities and facilities. The software gives complete online information (using European standards) with which the corresponding institutions and individuals can evaluate and control a facility's Radiation Safety and QA program. The software enables storage of all data in one place and sharing the same information (data), regardless of whether the measured data is used by an individual user or by an authorized institution. The software overcomes the distance and time separation of institutions and individuals who take part in QA. Upgrading the software will enable assessment of the medical exposure level to ionizing radiation.

  19. Upgrading Programs for Construction Journeymen. Final Report.

    ERIC Educational Resources Information Center

    Franklin, William S.

    The report describes a study of industry-sponsored upgrading programs for journeymen in construction unions. Interviews with union and training officials, as well as 405 journeymen and 99 contractors, revealed that upgrading activities were concentrated in electrical work, carpentry, and the pipe trades, and that both the number of programs and…

  20. Migration of the digital interactive breast-imaging teaching file

    NASA Astrophysics Data System (ADS)

    Cao, Fei; Sickles, Edward A.; Huang, H. K.; Zhou, Xiaoqiang

    1998-06-01

    The digital breast imaging teaching file developed during the last two years in our laboratory has been used successfully at UCSF (University of California, San Francisco) as a routine teaching tool for training radiology residents and fellows in mammography. Building on this success, we have ported the teaching file from an old Pixar imaging/Sun SPARC 470 display system to our newly designed telemammography display workstation (Ultra SPARC 2 platform with two DOME Md5/SBX display boards). The old Pixar/Sun 470 system, although adequate for fast and high-resolution image display, is 4- year-old technology, expensive to maintain and difficult to upgrade. The new display workstation is more cost-effective and is also compatible with the digital image format from a full-field direct digital mammography system. The digital teaching file is built on a sophisticated computer-aided instruction (CAI) model, which simulates the management sequences used in imaging interpretation and work-up. Each user can be prompted to respond by making his/her own observations, assessments, and work-up decisions as well as the marking of image abnormalities. This effectively replaces the traditional 'show-and-tell' teaching file experience with an interactive, response-driven type of instruction.

  1. Upgrading the Neutron Radiography Facility in South Africa (SANRAD): Concrete Shielding Design Characteristics

    NASA Astrophysics Data System (ADS)

    de Beer, F. C.; Radebe, M. J.; Schillinger, B.; Nshimirimana, R.; Ramushu, M. A.; Modise, T.

    A common denominator of all neutron radiography (NRAD) facilities worldwide is that the perimeter of the experimental chamber of the facility is a radiation shielding structure which,in some cases, also includes flight tube and filter chamber structures. These chambers are normally both located on the beam port floor outside the biological shielding of the neutron source. The main function of the NRAD-shielding structure isto maintain a radiological safe working environment in the entire beam hall according to standards set by individual national radiological safety regulations. In addition, the shielding's integrity and capability should not allow, during NRAD operations, an increase in radiation levels in the beam port hall and thus negatively affectadjacent scientific facilities (e.g. neutron diffraction facilities).As a bonus, the shielding for the NRAD facility should also prevent radiation scattering towards the detector plane and doing so, thus increase thecapability of obtaining better quantitative results. This paper addresses Monte Carlo neutron-particletransport simulations to theoretically optimize the shielding capabilities of the biological barrierfor the SANRAD facility at the SAFARI-1 nuclear research reactor in South Africa. The experimental process to develop the shielding, based on the principles of the ANTARES facility, is described. After casting, the homogeneity distribution of these concrete mix materials is found to be near perfect and first order experimental radiation shielding characteristicsthrough film badge (TLD) exposure show acceptable values and trends in neutron- and gamma-ray attenuation.

  2. Commentary: Should Gender Differences Be Included in the Evolutionary Upgrade to Cognitive Load Theory?

    ERIC Educational Resources Information Center

    Bevilacqua, Andy

    2017-01-01

    Recent upgrades to cognitive load theory suggest that evolutionary processes have shaped the way that working memory processes cultural and social information. According to evolutionarily educational psychologists, some forms of information are processed with lower working memory loads than other forms. The former are evolutionarily salient and…

  3. Habitat Demonstration Unit Medical Operations Workstation Upgrades

    NASA Technical Reports Server (NTRS)

    Trageser, Katherine H.

    2011-01-01

    This paper provides an overview of the design and fabrication associated with upgrades for the Medical Operations Workstation in the Habitat Demonstration Unit. The work spanned a ten week period. The upgrades will be used during the 2011 Desert Research and Technology Studies (Desert RATS) field campaign. Upgrades include a deployable privacy curtain system, a deployable tray table, an easily accessible biological waste container, reorganization and labeling of the medical supplies, and installation of a retractable camera. All of the items were completed within the ten week period.

  4. Building America Expert Meeting Report: Transitioning Traditional HVAC Contractors to Whole House Performance Contractors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burdick, A.

    This report outlines findings resulting from a U.S. Department of Energy Building America expert meeting to determine how HVAC companies can transition from a traditional contractor status to a service provider for whole house energy upgrade contracting. IBACOS has embarked upon a research effort under the Building America Program to understand business impacts and change management strategies for HVAC companies. HVAC companies can implement these strategies in order to quickly transition from a 'traditional' heating and cooling contractor to a service provider for whole house energy upgrade contracting. Due to HVAC service contracts, which allow repeat interaction with homeowners, HVACmore » companies are ideally positioned in the marketplace to resolve homeowner comfort issues through whole house energy upgrades. There are essentially two primary ways to define the routes of transition for an HVAC contractor taking on whole house performance contracting: (1) Sub-contracting out the shell repair/upgrade work; and (2) Integrating the shell repair/upgrade work into their existing business. IBACOS held an Expert Meeting on the topic of Transitioning Traditional HVAC Contractors to Whole House Performance Contractors on March 29, 2011 in San Francisco, CA. The major objectives of the meeting were to: Review and validate the general business models for traditional HVAC companies and whole house energy upgrade companies Review preliminary findings on the differences between the structure of traditional HVAC Companies and whole house energy upgrade companies Seek industry input on how to structure information so it is relevant and useful for traditional HVAC contractors who are transitioning to becoming whole house energy upgrade contractors Seven industry experts identified by IBACOS participated in the session along with one representative from the National Renewable Energy Laboratory (NREL). The objective of the meeting was to validate the general operational profile of an integrated whole house performance contracting company and identify the most significant challenges facing a traditional HVAC contractor looking to transition to a whole house performance contractor. To facilitate the discussion, IBACOS divided the business operations profile of a typical integrated whole house performance contracting company (one that performs both HVAC and shell repair/upgrade work) into seven Operational Areas with more detailed Business Functions and Work Activities falling under each high-level Operational Area. The expert panel was asked to review the operational profile or 'map' of the Business Functions. The specific Work Activities within the Business Functions identified as potential transition barriers were rated by the group relative to the value in IBACOS creating guidance ensuring a successful transition and the relative difficulty in executing.« less

  5. Overview of ICRP Committee 3: protection in medicine.

    PubMed

    Vañó, E; Miller, D L; Rehani, M M

    2016-06-01

    Committee 3 of the International Commission on Radiological Protection (ICRP) develops recommendations and guidance for protection of patients, staff, and the public against radiation exposure when ionising radiation is used for medical diagnosis, therapy, or biomedical research. This paper presents a summary of the work that Committee 3 has accomplished over the past few years, and also describes its current work. The most recent reports published by the Commission that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (Publication 129), 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (Publication 128, in cooperation with Committee 2), 'Radiological protection in ion beam radiotherapy' (Publication 127), 'Radiological protection in paediatric diagnostic and interventional radiology' (Publication 121), 'Radiological protection in cardiology' (Publication 120), and 'Radiological protection in fluoroscopically guided procedures outside the imaging department' (Publication 117). A new report on diagnostic reference levels in medical imaging will provide specific advice for interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and hybrid (multi-modality) imaging procedures, and is expected to be published in 2016. Committee 3 is also working on guidance for occupational radiological protection in brachytherapy, and on guidance on occupational protection issues in interventional procedures, paying particular attention to the 2011 Commission's recommendations on the occupational dose limit for the lens of the eye (Publication 118). Other reports in preparation deal with justification, radiological protection in therapy with radiopharmaceuticals, radiological protection in medicine as related to individual radiosusceptibility, appropriate use of effective dose (in cooperation with other Committees), and guidance for healthcare practitioners on radiological and patient protection. Committee 3 has also suggested specific priorities for research on radiological protection in medicine to the Commission. © The International Society for Prosthetics and Orthotics.

  6. Work plan for the radiological survey for the David Witherspoon, Incorporated, Landfill-1630 site, Knoxville, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-07-01

    This work plan establishes the methods and requirements for performing a radiological survey at the David Witherspoon, Incorporated, Landfill-1630 Site, Knoxville, Tennessee (DWI 1630 Site) in accordance with requirements under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The radiological survey will identify the radiological contamination level of the equipment and debris stored at the DWI 1630 Site. The data generated from the survey activities will support the decisions for characterization of the equipment/debris and aid in subsequent disposition and waste handling. The survey activities to be performed under this work plan include an equipment radiological survey,more » a walkover survey, and an immunoassay testing for polychlorinated biphenyls (PCBs). This work plan includes a quality assurance (QA)/quality control (QC) project plan, a health and safety (H&S) plan, and a waste management plan.« less

  7. Positive train control test bed interoperability upgrades.

    DOT National Transportation Integrated Search

    2013-02-01

    Transportation Technology Center, Inc. (TTCI) upgraded the Positive Train Control (PTC) Test Bed to support additional PTC testing configurations under Federal Railroad Administration (FRA) Task Order 270. The scope of work provided additional PTC Co...

  8. Water Shortage: Lessons in Conservation From the Great California Drought, 1976-1977

    NASA Astrophysics Data System (ADS)

    Showstack, Randy

    Legislation moving quickly through both houses of the U.S. Congress would establish a fund to promote and support research and development to increase the security of the nation's water infrastructure from source to faucet.The House of Representatives bill, "The Water Infrastructure Security and Research and Development Act" (HR 3178), would provide $12 million per year for fiscal years 2002-2006 for a number of research areas. These include assessing water supply systems for physical vulnerabilities, including biological, chemical, and radiological contamination; devising real-time systems to monitor water for contamination; determining mitigation options; and upgrading security technologies.

  9. [Survey on medical information education for radiologic technologists working at hospitals].

    PubMed

    Ikeda, Ryuji; Ogasawara, Katsuhiko; Okuda, Yasuo; Konishi, Yasuhiko; Ohoba, Hisateru; Hoshino, Shuhei; Hosoba, Minoru

    2011-01-01

    Recently, the importance of medical information for radiologic technologists has increased. The purpose of this questionnaire survey was to clarify the method of acquiring skill in medical information for radiologic technologists from the point of view of the managers of radiology departments. The questionnaire was sent to 260 hospitals that had introduced picture archiving and communication systems (PACSs) for the person responsible for medical information in the radiology department. The response rate was 35.4% (92 hospitals). The results of this survey clarified that few hospital have staff for medical information in the radiology department. Nevertheless, the excellent staff who have the skills to troubleshoot and develop systems are earnestly needed in radiology departments. To solve this problem, many technologists should understand the content, work load, and necessity of medical information. In addition, cooperation between radiologic technologist schools and hospitals is important in the field of medical information education.

  10. infoRAD: computers for clinical practice and education in radiology. Teleradiology, information transfer, and PACS: implications for diagnostic imaging in the 1990s.

    PubMed

    Schilling, R B

    1993-05-01

    Picture archiving and communication systems (PACS) provide image viewing at diagnostic, reporting, consultation, and remote workstations; archival on magnetic or optical media by means of short- or long-term storage devices; communications by means of local or wide area networks or public communication services; and integrated systems with modality interfaces and gateways to health care facilities and departmental information systems. Research indicates three basic needs for image and report management: (a) improved communication and turnaround time between radiologists and other imaging specialists and referring physicians, (b) fast reliable access to both current and previously obtained images and reports, and (c) space-efficient archival support. Although PACS considerations are much more complex than those associated with single modalities, the same basic purchase criteria apply. These criteria include technical leadership, image quality, throughput, life cost (eg, initial cost, maintenance, upgrades, and depreciation), and total service. Because a PACS takes much longer to implement than a single modality, the customer and manufacturer must develop a closer working relationship than has been necessary in the past.

  11. Energy Efficiency Upgrades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roby Williams

    2012-03-29

    The energy efficiency upgrades project at Hardin County General Hospital did not include research nor was it a demonstration project. The project enabled the hospital to replace outdated systems with modern efficient models. Hardin County General Hospital is a 501c3, nonprofit hospital and the sole community provider for Hardin and Pope Counties of Illinois. This project provided much needed equipment and facility upgrades that would not have been possible through locally generated funding. Task 1 was a reroofing of the hospital. The hospital architect designed the replacement to increase the energy efficiency of the hospital roof/ceiling structure. Task 2 wasmore » replacement and installation of a new more efficient CT scanner for the hospital. Included in the project was replacement of HVAC equipment for the entire radiological suite. Task 5 was a replacement and installation of a new higher capacity diesel-fueled emergency generator for the hospital replacing a 50+ year old gas-fired generator. Task 7 was the replacement of 50+ year-old walk-in cooler/freezer with a newer, energy efficient model. Task 8 was the replacement of 10+ year-old washing machines in the hospital laundry with higher capacity, energy efficient models. Task 9 was replacement of 50-year old single pane curtain window system with double-pane insulated windows. Additionally, insulation was added around ventilation systems and the curtain wall system.« less

  12. Formation of an environmental restoration user group for radiological controls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, R.L.

    1993-12-31

    An Environmental Restoration User Group for Radiological Controls will be proposed. Article 116 of the Radiological Control Manual encourages contractors to establish informal working associations that promote dialogue among similar facilities. Chem-Nuclear Geotech, Inc., is willing to initially organize and lead a users group to work on common problems, define standard methods, publish a Radiological Work Practices Handbook, and recommend regulatory changes to make environmental restoration programs more cost effective without compromising radiological control. A charter for the users group will be proposed. A questionnaire will be distributed to interested persons to assist in development of focus groups and agendamore » items for the first meeting. The first meeting is planned for May 25-26, 1993, in Grand Junction Colorado. All interested persons are welcome to attend.« less

  13. Prostate Upgrading Team Project — EDRN Public Portal

    Cancer.gov

    Aim 1: We will develop a risk assessment tool using commonly-collected clinical information from a series of contemporary radical prostatectomies to predict the risk of prostate cancer upgrading to high grade cancer at radical prostatectomy. These data will be combined as a part of our Early Detection Research Network (EDRN) GU Working Group into a risk assessment tool; this tool will be named the EDRN Prostatectomy Upgrading Calculator or (EPUC).

  14. Evaluation of Stress and a Stress-Reduction Program Among Radiologic Technologists.

    PubMed

    Reingold, Lynn

    2015-01-01

    To investigate stress levels and causes of stress among radiologic technologists and determine whether an intervention could reduce stress in a selected radiologic technologist population. Demographic characteristics and data on preintervention stress sources and levels were collected through Internet-based questionnaires. A 6-week, self-administered, mindfulness-based stress-reduction program was conducted as a pilot intervention with 42 radiologic technologists from the Veterans Administration Medical Center. Data also were collected postintervention. Identified sources of stress were compared with findings from previous studies. Some radiologic technologists experienced improvement in their perceptions of stress after the intervention. Sources of stress for radiologic technologists were similar to those shown in earlier research, including inconsistent management, poor management communication, conflicting demands, long work hours, excessive workloads, lack of work breaks, and time pressures. The mindfulness-based stress-reduction program is an example of an inexpensive method that could improve personal well-being, reduce work errors, improve relationships in the workplace, and increase job satisfaction. More research is needed to determine the best type of intervention for stress reduction in a larger radiologic technologist population.

  15. Concordant, non-atypical breast papillomas do not require surgical excision: A 10-year multi-institution study and review of the literature.

    PubMed

    Grimm, Lars J; Bookhout, Christine E; Bentley, Rex C; Jordan, Sheryl G; Lawton, Thomas J

    2018-05-01

    Non-atypical papillomas (NAPs) diagnosed on core needle biopsy (CNB) frequently undergo surgical excision due to highly variable upstaging rates. The purpose of this study is to document our dual-institution upgrade rates of NAPs diagnosed on core needle biopsy and review the upgrade rates reported in the literature. Following IRB approval, CNB results from Duke University (7/1/2004-6/30/2014) and the University of North Carolina Chapel Hill (1/1/04-6/30/2013) were reviewed to identify non-atypical papillomas. All cases with surgical excision or 2 years of imaging follow up were included. In addition, a literature review identified 60 published studies on upgrades of NAPs diagnosed at CNB. Cases in our cohort and the published literature were reviewed for confounding factors: [1] missing radiologic-pathologic concordance and/or discordance, [2] papillomas included with high-risk lesions, [3] high risk lesions counted as upgrades, [4] review by a nonspecialized breast pathologist, and [5] cancer incidentally detected. Of the 388 CNBs in our dual-institution cohort, 136 (35%) patients underwent surgical excision and 252 (65%) patients had imaging follow up. After controlling for confounders, no cancers (0/388) were found at surgical excision or during follow up imaging. The literature review upstaging rate was 4.0% (166/4157) but 1.8% (4/227) after excluding studies with confounders. The combined upstaging rate from the literature and this study was 0.6% (4/615). The upstaging rate for CNB diagnosed NAPs was 0% in our cohort and 0.6% overall after adjusting for confounders. This low rate does not warrant reflexive surgical excision and diagnostic imaging follow up should be discretionary. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Asymptomatic Benign Papilloma Without Atypia Diagnosed at Ultrasonography-Guided 14-Gauge Core Needle Biopsy: Which Subgroup can be Managed by Observation?

    PubMed

    Kim, Soo-Yeon; Kim, Eun-Kyung; Lee, Hye Sun; Kim, Min Jung; Yoon, Jung Hyun; Koo, Ja Seung; Moon, Hee Jung

    2016-06-01

    For asymptomatic benign papillomas detected at ultrasonography-guided 14-gauge core-needle biopsy (US-CNB), the decision to perform excision versus observation has been a topic of debate. We sought to determine which subgroup of asymptomatic benign papillomas without atypia diagnosed at US-CNB can be safely managed by observation versus immediate excision. Overall, 230 asymptomatic benign papillomas in 197 women (mean age 46.6 ± 9.5 years; range 22-78), diagnosed at US-CNB using immunohistochemistry staining when needed and then managed by surgery (n = 144) or vacuum-assisted excision (VAE) with at least 12 months of follow-up after benign VAE results (n = 86) were included in this study. The upgrade rate to malignancy was calculated. Clinical and radiological variables, including age, size, Breast Image Reporting and Data System (BI-RADS) category, and imaging-pathology correlation were evaluated to find associations with malignancy using multivariate analysis. The upgrade rate to malignancy was 2.6 % (6 of 230): four were ductal carcinomas in situ and two were 1.5- and 9-mm-sized invasive ductal carcinomas without lymph node metastasis. The upgrade rates of papillomas with a BI-RADS category 3-4a and imaging-pathology concordance were 1.4 and 1.8 %, respectively. Category 4b-5 and imaging-pathology discordance were independently associated with malignancy, with upgrade rates of 13 and 50 %, respectively. Age and lesion size were not associated with malignancy. Asymptomatic benign papillomas with probable benign or low suspicious US features or imaging-pathology concordance can be followed-up as opposed to immediate excision.

  17. 2016 Annual Site Environmental Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finley, Virginia

    This report provides the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory’s (PPPL) operations. The results of the 2016 environmental surveillance and monitoring program for PPPL’s are presented and discussed. The report also summarizes environmental initiatives, assessments, and community involvement programs that were undertaken in 2016. PPPL has engaged in fusion energy research since 1951. The vision of the Laboratory is to create innovations to make fusion power a practical reality – a clean,more » alternative energy source. 2016 marked the eighteenth year of National Spherical Torus Experiment and the first year of NSTX-U (Upgrade) operations. The NSTX-U Project is a collaboration among national laboratories, universities, and national and international research institutions and is a major element in the US Fusion Energy Sciences Program. Its design tests the physics principles of spherical torus (ST) plasmas, playing an important role in the development of smaller, more economical fusion reactors. NSTX-U began operations after its first upgrade that installed the new center stack magnets and second neutral beam, which would allow for hotter plasmas and greater field strength to maintain the fusion reaction longer. Due to operational issues with a poloidal coil, NSTX-U operated briefly in 2016. In 2016, PPPL’s radiological environmental monitoring program measured tritium in the air at the NSTX-U Stack and at on -site sampling stations. Using highly sensitive monitors, PPPL is capable of detecting small changes in the ambient levels of tritium. The operation of an in- stack monitor located on D-site is used to demonstrate compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations. Also included in PPPL’s radiological environmental monitoring program, are water monitoring – ground and surface, and waste waters. PPPL’s radiological monitoring program characterized the background levels of tritium in the environment; the data are presented in this report. Ground water monitoring continued under the New Jersey Department of Environmental Protection’s Site Remediation Program. PPPL monitored for non-radiological contaminants, mainly volatile organic compounds (components of chlorinated degreasing solvents). In 2016, PPPL was in compliance with its permit limits for surface and sanitary discharges, excepting two elevated chlorine-produced oxidant concentration. PPPL was honored with awards for its waste reduction and recycling program, and its “EPEAT” electronics purchasing for the third consecutive year.« less

  18. Who will be the Radiologists of Tomorrow? A survey of radiology during the "Practical Year" in Germany.

    PubMed

    Dettmer, Sabine; Fischer, Volkhard; Paeßens, Carolin; Meyer, Simone; Wacker, Frank K; Rodt, Thomas

    2017-10-01

    Purpose  Aim of our study was to evaluate the motivation of medical students in their final year of medical school to choose radiology for further specialization by means of a Germany-wide survey. Materials and Methods  The survey was performed during the 2015/16 semester among German medical students in their four months radiology elective during the final year. Invitations for the study were distributed by the Student Secretariats of each university. The survey was web-based with EvaSys 7.0 software. Questions on radiology contents during medical studies and "practical year" were part of the survey. Plans for residency and possible advantages and disadvantages of radiology as medical specialty were inquired. Descriptive statistics and group comparisons were used as analysis methods. Results  89 students participated in the survey at the beginning and 60 students at the end of the practical year. Of these 39 students could be identified who answered both questionnaires. Most students were satisfied with their final year radiology elective (mean 1.8 on a range from 1 to 5). Nevertheless, they criticized mentoring during routine work (mean 2.1) and a lack of educational courses (mean 2.1). Most students (83 %) were uncertain about their residency choice at the beginning of their "practical year" and about one fifth changed their plans. From the students' point of view main advantages of radiology included contact with many other clinical disciplines (87 %) and the working conditions (68 %). The reduced patient contact (42 %), the large amount of work at a computer (43 %), and the dependency on referring physicians (42 %) were regarded as the main disadvantages. The students regarded the way radiology is taught during the studies as not practical enough. With regard to radiology the majority of students (63 %) felt poorly prepared for their future work. Conclusion  The "practical year" is important regarding the choice of future specialization. There was a high degree of satisfaction with the "practical year" in radiology. The mentoring during routine work and a lack of educational courses was mildly criticized. These factors provide room for improvement to foster students' interest in radiology. Key Points   · The "practical year" is important regarding the choice of further specialization.. · Criticisms of radiology in the "practical year" were mentoring and courses.. · Students feel poorly prepared for their future work regarding practical radiological skills.. Citation Format · Dettmer S, Fischer V, Paeßens C et al. Who will be the Radiologists of Tomorrow? A survey of radiology during the "Practical Year" in Germany. Fortschr Röntgenstr 2017; 189: 967 - 976. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Biogas upgrading and utilization: Current status and perspectives.

    PubMed

    Angelidaki, Irini; Treu, Laura; Tsapekos, Panagiotis; Luo, Gang; Campanaro, Stefano; Wenzel, Henrik; Kougias, Panagiotis G

    Biogas production is an established sustainable process for simultaneous generation of renewable energy and treatment of organic wastes. The increasing interest of utilizing biogas as substitute to natural gas or its exploitation as transport fuel opened new avenues in the development of biogas upgrading techniques. The present work is a critical review that summarizes state-of-the-art technologies for biogas upgrading and enhancement with particular attention to the emerging biological methanation processes. The review includes comprehensive description of the main principles of various biogas upgrading methodologies, scientific and technical outcomes related to their biomethanation efficiency, challenges that have to be addressed for further development and incentives and feasibility of the upgrading concepts. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Artifice, Interpretation and Nature: Key Categories in Radiology Work

    NASA Astrophysics Data System (ADS)

    Nyce, James M.

    This paper extends on some prior work on nature, culture and computation. This paper will look at “image work” in a radiology department, i.e, how radiologists use images and other kinds of knowledge in daily clinical work. In particular, the paper will look at the role tacit knowledge and categories have in the work radiologists carry out. How radiologists make use of and contrast analog and digital representations of nature will be explored here because this is key to how radiologists work and think. In other words, the role that computer derived artifacts, correspondence theory and mimesis play in the clinical work of radiology will be discussed.

  1. Specialising in radiology in Switzerland: still attractive for medical school graduates?

    PubMed

    Buddeberg-Fischer, B; Hoffmann, A; Christen, S; Weishaupt, D; Kubik-Huch, R A

    2012-07-01

    To gain insight into the professional characteristics of radiologists in Switzerland and to determine how to enhance the attractiveness of radiology to medical graduates as a specialty. Data from 262 members of the Swiss Society of Radiology (m:f = 76:24%) obtained in a questionnaire survey were analysed regarding socio-demographic variables, working status, specialty, main fields of interest, career success, mentoring and reasons for the shortage of radiologists. 35 (56.4%) female and 85 (45.5%) male radiologists were aged ≤ 45 years. 228 (87%) were board-certified; 44 (17.9%) had completed a sub-specialisation. Men worked part-time mostly just before retirement, while women worked part-time at a younger age. As reasons for specialty choice, the wide range of clinical work and the combination of technology and medicine were ranked highest. Women reported significantly less career success and support. To improve the attractiveness of radiology to graduates, radiology should be visible on medical school curricula. In Switzerland, more female radiologists work part-time than male ones, and there is less career success and support for women. In order to make radiology more attractive to medical graduates as a specialty, structured residency programmes and reliable gender-respecting career support are needed. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. 47 CFR 27.1164 - The cost-sharing formula.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...); installation; systems testing; FCC filing costs; site acquisition and civil works; zoning costs; training... upgrades for interference control; power plant upgrade (if required); electrical grounding systems; Heating Ventilation and Air Conditioning (HVAC) (if required); alternate transport equipment; and leased facilities...

  3. Upgrading the Underemployed in the Work Environment: Volume 1 through 4 and Summary of the 4-Volume Report. Final Report.

    ERIC Educational Resources Information Center

    Skill Achievement Inst., Lake Success, NY.

    This is a report on 18 months of work done in an experimental and demonstration project designed to develop ways to meet in-plant skill needs by upgrading the job skills of entry level (mostly minority group) workers and by improving capacity for better employee-supervisor relationships. Project activity took place in three cities--Newark,…

  4. Factors influencing career choices in radiology trainees in Queensland, Australia.

    PubMed

    Ip, S W; Ko, H S; Applegate, K E

    2010-04-01

    The aim of this study was to investigate factors influencing career choices in radiology trainees. We distributed a 27-question written survey to all radiology registrars in Queensland. The questions investigated whether radiology was their first specialty choice, career satisfaction, ideal working conditions and attitudes regarding having children during the time of training. Forty-four of 51 surveys were returned (86% participation rate, 73% men, P = 0.048055) with 100% reporting a high job satisfaction; 28% of male registrars compared to 8% of female registrars did extra work outside of training to earn extra money (P = 0.000003), and 17% of female registrars took a leave of absence during their training, while no male registrar did (P = 0.087923). Only one female trainee worked part-time (P = 0.272727). In addition, 58% of female registrars planned a pregnancy (P = 0.731789) before completion of training; 83% of women versus 75% of men had no children (P = 0.329263). Only 5% of trainees agreed that it was easy to arrange part-time training, only 14% stated that it was easy to negotiate flexible work schedules and 7% agreed that it was easy to return to work after a period of absence. 'Time spent with immediate family' was rated the most important lifestyle factor, followed by 'work hours' and 'on-call duty'. The least important factors were 'being away from extended family', 'availability of part-time work' and whether 'work was in a rural location'. Overall job satisfaction is high among radiology trainees. Nevertheless, lifestyle factors, particularly those related to work time, are becoming more important for career decisions. This should be taken into account when designing and structuring radiology training to ensure that it is considered an attractive career choice.

  5. Management of intraductal papilloma without atypia of the breast diagnosed on core biopsy: Size and sampling matter.

    PubMed

    Symbol, Brittany; Ricci, Andrew

    2018-04-23

    Due to the potential for atypia (atypical ductal or lobular hyperplasia) or carcinoma (in situ or invasive) on excision, aggressive reflex surgical excision protocols following core biopsy diagnosis of papillary lesions of the breast (ie, intraductal papilloma) are commonplace. Concepts in risk stratification, including radiologic-pathologic correlation, are emerging in an effort to curb unnecessary surgeries. To this end, we examined all excised intraductal papillomas diagnosed at our institution from 2010-2015 (N = 336) and found an overall atypia rate of 20%. To investigate further, we stratified all excised papillomas according to total lesion size (range = 1-40 mm) and found that the atypia rate for lesions ≤1.2 cm (16% with atypia) was statistically significantly lower (P = .008) than the atypia rate for lesions >1.2 cm (36% with atypia). To explore to effects of radiologic-pathologic correlation on the ability of the core biopsy to accurately predict nonatypical lesions we assessed thirteen consecutive paired nonatypical core biopsy/follow-up surgical excision specimens for the percent of the total lesion (on imaging) sampled by the core biopsy (measured histologically). None of the thirteen paired specimens showed upgrade on excision (0/13); the percent of total lesion sampled by biopsy in this cohort averaged 59%. We propose that in the absence of discordant clinical/radiological findings, small lesions (≤1.2 cm) with radiologic-pathologic concordance (>50% sampling of total lesion by core biopsy) may safely forego surgery for close clinical and radiographic follow-up. © 2018 Wiley Periodicals, Inc.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillmer, Kurt T.

    This course presents information on radiological work permits (RWPs), various types of postings used in radiological areas, radiological area setups, access controls, and releases of material from radiological areas. All of these are fundamental duties of RCTs. This course will prepare the student with the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and providing in-thefield skills.

  7. Westinghouse corporate development of a decision software program for Radiological Evaluation Decision Input (REDI)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bush, T.S.

    1995-03-01

    In December 1992, the Department of Energy (DOE) implemented the DOE Radiological Control Manual (RCM). Westinghouse Idaho Nuclear Company, Inc. (WINCO) submitted an implementation plan showing how compliance with the manual would be achieved. This implementation plan was approved by DOE in November 1992. Although WINCO had already been working under a similar Westinghouse RCM, the DOE RCM brought some new and challenging requirements. One such requirement was that of having procedure writers and job planners create the radiological input in work control procedures. Until this time, that information was being provided by radiological engineering or a radiation safety representative.more » As a result of this requirement, Westinghouse developed the Radiological Evaluation Decision Input (REDI) program.« less

  8. USP <800> Adds Significant Safety Standards: Facility Upgrades Needed to Protect Employees From Hazardous Drugs.

    PubMed

    Beans, Bruce E

    2017-05-01

    The new USP standard for handling hazardous drugs (HDs) will require millions of dollars in capital outlays for facility and equipment upgrades and also requires in-depth assessments of each HD that facilities handle, significant workflow and work practice changes, and thorough staff training.

  9. Characterization of detector-systems based on CeBr3, LaBr3, SrI2 and CdZnTe for the use as dosemeters

    NASA Astrophysics Data System (ADS)

    Kessler, P.; Behnke, B.; Dombrowski, H.; Neumaier, S.

    2017-11-01

    For the upgrade of existing dosimetric early warning networks in Europe spectrometric detectors based on CeBr3, LaBr3, SrI2, and CdZnTe are investigated as possible substitutes for the current detector generation which is mainly based on gas filled detectors. The additional information on the nuclide vector which can be derived from the spectra of γ-radiation is highly useful for an appropriate response in case of a nuclear or radiological accident. The measured γ-spectra will be converted into ambient dose equivalent H* (10) using a method where the spectrum is subdivided into multiple energy bands. For each band the conversion coefficients from count rate to dose rate is determined. The derivation of these conversion coefficients is explained in this work. Both experimental and simulative approaches are investigated using quasi-mono-energetic γ-sources and synthetic spectra from Monte-Carlo simulations to determine the conversion coefficients for each detector type. Finally, precision of the obtained characterization is checked by irradiation of the detectors in different well-known photon fields with traceable dose rates.

  10. Radiation protection challenges in the management of radioactive waste from high-energy accelerators.

    PubMed

    Ulrici, Luisa; Algoet, Yvon; Bruno, Luca; Magistris, Matteo

    2015-04-01

    The European Laboratory for Particle Physics (CERN) has operated high-energy accelerators for fundamental physics research for nearly 60 y. The side-product of this activity is the radioactive waste, which is mainly generated as a result of preventive and corrective maintenance, upgrading activities and the dismantling of experiments or accelerator facilities. Prior to treatment and disposal, it is common practice to temporarily store radioactive waste on CERN's premises and it is a legal requirement that these storage facilities are safe and secure. Waste treatment typically includes sorting, segregation, volume and size reduction and packaging, which will depend on the type of component, its chemical composition, residual activity and possible surface contamination. At CERN, these activities are performed in a dedicated waste treatment centre under the supervision of the Radiation Protection Group. This paper gives an overview of the radiation protection challenges in the conception of a temporary storage and treatment centre for radioactive waste in an accelerator facility, based on the experience gained at CERN. The CERN approach consists of the classification of waste items into 'families' with similar radiological and physical-chemical properties. This classification allows the use of specific, family-dependent techniques for radiological characterisation and treatment, which are simultaneously efficient and compliant with best practices in radiation protection. The storage was planned on the basis of radiological and other possible hazards such as toxicity, pollution and fire load. Examples are given of technical choices for the treatment and radiological characterisation of selected waste families, which could be of interest to other accelerator facilities. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Attitudes of Radiologic Science Students, Technologists, and Clinical Instructors Regarding Their Experiential Learning and Career Capacity

    ERIC Educational Resources Information Center

    Burns, Caroline

    2012-01-01

    Radiologic science is an essential part of the healthcare continuum and preparing radiologic science students with experiential learning is essential. It is from this experience working with the patient that students begin to prepare for entry-level practice. The purpose of the study was to examine the attitudes of current radiologic science…

  12. Upgrade of ROV Super GNOME Pro for Underwater Monitoring in the Caspian Sea

    NASA Astrophysics Data System (ADS)

    Rozman, B. Ya.; Elkin, A. V.; Kaptsov, A. S.; Ermakov, I. D.; Ermakov, D. I.; Krasnov, V. G.; Kondrashov, L. S.

    2018-01-01

    A description and characteristics of the small-size remotely operated underwater vehicle Super GNOME pro are given. The main technical innovations and upgrades of the vehicle are considered along with the reasons and aims of these improvements. The innovations were evaluated during expedition work in northern Caspian Sea in 2016, which demonstrated good results. Further upgrades include installation of a sediment-penetrating thermometer for measuring the thermal background of benthonic soil and an underwater dosimeter/radiometer for assessing the radiation background of water areas.

  13. ALPHA: A Case Study in Upgrading.

    ERIC Educational Resources Information Center

    Granick, Leonard P. R.; And Others

    An industry-focused upgrading model, based upon job redesigns of entry-level and higher skill positions and a multi-step diagonal/vertical progression ladder was installed in a company having a 150-employee blue collar work force. The model provided for rapid promotion and wage increases of both present employees and new hires, supported by skills…

  14. Psychological Selection of NASA Astronauts for International Space Station Missions

    NASA Technical Reports Server (NTRS)

    Galarza, Laura

    1999-01-01

    During the upcoming manned International Space Station (ISS) missions, astronauts will encounter the unique conditions of living and working with a multicultural crew in a confined and isolated space environment. The environmental, social, and mission-related challenges of these missions will require crewmembers to emphasize effective teamwork, leadership, group living and self-management to maintain the morale and productivity of the crew. The need for crew members to possess and display skills and behaviors needed for successful adaptability to ISS missions led us to upgrade the tools and procedures we use for astronaut selection. The upgraded tools include personality and biographical data measures. Content and construct-related validation techniques were used to link upgraded selection tools to critical skills needed for ISS missions. The results of these validation efforts showed that various personality and biographical data variables are related to expert and interview ratings of critical ISS skills. Upgraded and planned selection tools better address the critical skills, demands, and working conditions of ISS missions and facilitate the selection of astronauts who will more easily cope and adapt to ISS flights.

  15. Feedback-controlled NTM stabilization on ASDEX Upgrade

    NASA Astrophysics Data System (ADS)

    Stober, J.; Barrera, L.; Behler, K.; Bock, A.; Buhler, A.; Eixenberger, H.; Giannone, L.; Kasparek, W.; Maraschek, M.; Mlynek, A.; Monaco, F.; Poli, E.; Rapson, C. J.; Reich, M.; Schubert, M.; Treutterer, W.; Wagner, D.; Zohm, H.

    2015-03-01

    On ASDEX Upgrade a concept for real-time stabilization of NTMs has been realized and successfully applied to (3,2)- and (2,1)-NTMs. Since most of the work has meanwhile been published elsewhere, a short summary with the appropriate references is given. Limitations, deficits and future extensions of the system are discussed. In a second part the recent work on using modulated ECCD for NTM stabilisation is described in some detail. In these experiments ECCD power is modulated according to a magnetic footprint of the rotating NTM. In agreement with earlier results it could be shown that O-point heating reduces the necessary average power for stabilisation whereas X-point heating hampers stabilisation. Although this modulated scheme is not relevant for routine NTM stabilisation on ASDEX Upgrade it may be mandatory for ITER or DEMO. On ASDEX Upgrade it has been re-developed to demonstrate the usage of a FAst DIrectional Switch to continously heat the O-point of the rotating island with only one gyrotron switching between two launchers which target the mode at locations separated in phase by 180 degrees as described in [1].

  16. Neutronographic investigations of supramolecular structures on upgraded small-angle spectrometer YuMO

    NASA Astrophysics Data System (ADS)

    Kuklin, A. I.; Rogachev, A. V.; Soloviov, D. V.; Ivankov, O. I.; Kovalev, Yu S.; Utrobin, P. K.; Kutuzov, S. A.; Soloviev, A. G.; Rulev, M. I.; Gordeliy, V. I.

    2017-05-01

    Abstract.The work is a review of neutronographic investigations of supramolecular structures on upgraded small-angle spectrometer YuMO. Here, key parameters of small-angle spectrometers are considered. It is shown that two-detector system is the basis of YuMO upgrade. It allows to widen the dynamic q-range twice. In result, the available q-range is widened and dynamic q-range and data collection rate are doubled. The detailed description of YuMO spectrometer is given.The short review of experimental researches made on the spectrometer in the polymers field, biology, material science and physical chemistry is given. The current investigations also have a methodological aspect. It is shown that upgraded spectrometer provides advanced world level of research of supramolecular structures.

  17. The quality and impact of computer supported collaborative learning (CSCL) in radiology case-based learning.

    PubMed

    Kourdioukova, Elena V; Verstraete, Koenraad L; Valcke, Martin

    2011-06-01

    The aim of this research was to explore (1) clinical years students' perceptions about radiology case-based learning within a computer supported collaborative learning (CSCL) setting, (2) an analysis of the collaborative learning process, and (3) the learning impact of collaborative work on the radiology cases. The first part of this study focuses on a more detailed analysis of a survey study about CSCL based case-based learning, set up in the context of a broader radiology curriculum innovation. The second part centers on a qualitative and quantitative analysis of 52 online collaborative learning discussions from 5th year and nearly graduating medical students. The collaborative work was based on 26 radiology cases regarding musculoskeletal radiology. The analysis of perceptions about collaborative learning on radiology cases reflects a rather neutral attitude that also does not differ significantly in students of different grade levels. Less advanced students are more positive about CSCL as compared to last year students. Outcome evaluation shows a significantly higher level of accuracy in identification of radiology key structures and in radiology diagnosis as well as in linking the radiological signs with available clinical information in nearly graduated students. No significant differences between different grade levels were found in accuracy of using medical terminology. Students appreciate computer supported collaborative learning settings when tackling radiology case-based learning. Scripted computer supported collaborative learning groups proved to be useful for both 5th and 7th year students in view of developing components of their radiology diagnostic approaches. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  18. Space Station Upgrades Continue on This Week @NASA – March 31, 2017

    NASA Image and Video Library

    2017-03-31

    Work continues aboard the International Space Station on upgrades to prepare it for future operational activities. Ground controllers, using the station’s robotic arm, moved the Pressurized Mating Adapter-3 (PMA-3) from the Tranquility module to the station’s Harmony module March 26. PMA-3 will be outfitted with one of two International Docking Adapters to accommodate U.S. commercial spacecraft carrying astronauts on future missions. Four days after the PMA-3 move, NASA’s Shane Kimbrough and Peggy Whitson conducted the second in a series of three planned spacewalks to complete work related to the upgrades. The third spacewalk is planned in April. Also, James Webb Space Telescope Completes Acoustic and Vibration Tests, MAVEN Data Helps Measure Loss of Mars’ Atmosphere, Getting Excited About STEM, and New NASA App for Amazon Fire TV!

  19. Differential Motivations for Pursuing Diagnostic Radiology by Gender: Implications for Residency Recruitment.

    PubMed

    Grimm, Lars J; Lowell, Dorothy A; Cater, Sarah W; Yoon, Sora C

    2017-10-01

    The purpose of this study is to determine how the motivations to pursue a career in radiology differ by gender. In addition, the influence of medical school radiology education will be assessed. Radiology applicants to our institution from the 2015-2016 interview season were offered an online survey in February 2016. Respondents scored the influence of 24 aspects of radiology on their decision to pursue radiology. Comparisons were made between male and female respondents. Respondents were also asked the type of medical school radiology education they received and to score the influence this experience had on their decision to pursue radiology. There were 202 total respondents (202/657) including 47 women and 155 men. Compared to men, the following factors had a more negative impact on women: flexible work hours (P = 0.04), work environment (P = 0.04), lifestyle (P = 0.04), impact on patient care (P = 0.05), high current debt load (P = 0.02), gender distribution of the field (P = 0.04), and use of emerging/advanced technology (P = 0.02). In contrast, women felt more favorably about the opportunities for leadership (P = 0.04) and research (P < 0.01). Dedicated radiology exposure was as follows: 20% (n = 20) none, 48% (n = 96) preclinical exposure, 55% (n = 111) elective rotation, and 18% (n = 37) core rotation. More intensive radiology exposure via a core rotation had a significantly positive impact on the decision to pursue radiology (P < 0.01). Male and female radiology applicants are motivated by different aspects of radiology, which may influence residency recruitment practices. In addition, more intensive radiology exposure has a net positive impact on the decision to pursue radiology. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  20. Technologies for Upgrading Light Water Reactor Outlet Temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel S. Wendt; Piyush Sabharwall; Vivek Utgikar

    Nuclear energy could potentially be utilized in hybrid energy systems to produce synthetic fuels and feedstocks from indigenous carbon sources such as coal and biomass. First generation nuclear hybrid energy system (NHES) technology will most likely be based on conventional light water reactors (LWRs). However, these LWRs provide thermal energy at temperatures of approximately 300°C, while the desired temperatures for many chemical processes are much higher. In order to realize the benefits of nuclear hybrid energy systems with the current LWR reactor fleets, selection and development of a complimentary temperature upgrading technology is necessary. This paper provides an initial assessmentmore » of technologies that may be well suited toward LWR outlet temperature upgrading for powering elevated temperature industrial and chemical processes during periods of off-peak power demand. Chemical heat transformers (CHTs) are a technology with the potential to meet LWR temperature upgrading requirements for NHESs. CHTs utilize chemical heat of reaction to change the temperature at which selected heat sources supply or consume thermal energy. CHTs could directly utilize LWR heat output without intermediate mechanical or electrical power conversion operations and the associated thermodynamic losses. CHT thermal characteristics are determined by selection of the chemical working pair and operating conditions. This paper discusses the chemical working pairs applicable to LWR outlet temperature upgrading and the CHT operating conditions required for providing process heat in NHES applications.« less

  1. Evaluation of awareness on radiation protection and knowledge about radiological examinations in healthcare professionals who use ionized radiation at work.

    PubMed

    Yurt, Ayşegül; Cavuşoğlu, Berrin; Günay, Türkan

    2014-06-01

    In this study, we evaluated the knowledge and perception and mitigation of hazards involved in radiological examinations, focusing on healthcare personnel who are not in radiation-related occupations, but who use ionising radiation as a part of their work. A questionnaire was applied to physicians, nurses, technicians and other staff working in different clinics that use radiation in their work, in order to evaluate their knowledge levels about ionizing radiation and their awareness about radiation doses resulting from radiological examinations. The statistical comparisons between the groups were analyzed with the Kruskal Wallis test using the SPSS program. Ninety two participants took part in the study. Their level of knowledge about ionizing radiation and doses in radiological examinations were found to be very weak. The number of correct answers of physicians, nurses, medical technicians and other personnel groups were 15.7±3.7, 13.0±4.0, 10.1±2.9 and 11.8±4.0, respectively. In the statistical comparison between the groups, the level of knowledge of physicians was found to be significantly higher than the level of the other groups (p=0.005). The present study demonstrated that general knowledge in relation to radiation, radiation protection, health risks and doses used for radiological applications are insufficient among health professions using with ionizing radiation in their work.

  2. D0 Silicon Upgrade: Lower Cleanroom Roof Quick Load Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rucinski, Russ; /Fermilab

    1995-11-17

    This engineering note documents calculations done to determine the margin of safety for the lower clean room roof. The analysis was done to give me a feeling of what the loads, stresses and capacity of the roof is prior to installation and installation work to be done for the helium refrigerator upgrade. The result of this quick look showed that the calculated loads produce stress values and loads at about half the allowables. Based on this result, I do not think that special precautions above personal judgement are required for the installation work.

  3. Detection Performance of Upgraded "Polished Panel" Optical Receiver Concept on the Deep-Space Network's 34 Meter Research Antenna

    NASA Technical Reports Server (NTRS)

    Vilnrotter, Victor A.

    2012-01-01

    Initial optical communications experiments with a Vertex polished aluminum panel have been described. The polished panel was mounted on the main reflector of the DSN's research antenna at DSS-13. The PSF was recorded via remotely controlled digital camera mounted on the subreflector structure. Initial PSF generated by Jupiter showed significant tilt error and some mechanical deformation. After upgrades, the PSF improved significantly, leading to much better concentration of light. Communications performance of the initial and upgraded panel structure were compared. After the upgrades, simulated PPM symbol error probability decreased by six orders of magnitude. Work is continuing to demonstrate closed-loop tracking of sources from zenith to horizon, and better characterize communications performance in realistic daytime background environments.

  4. SLHC, the High-Luminosity Upgrade (public event)

    ScienceCinema

    None

    2017-12-09

    In the morning of June 23rd a public event is organised in CERN's Council Chamber with the aim of providing the particle physics community with up-to-date information about the strategy for the LHC luminosity upgrade and to describe the current status of preparation work. The presentations will provide an overview of the various accelerator sub-projects, the LHC physics prospects and the upgrade plans of ATLAS and CMS. This event is organised in the framework of the SLHC-PP project, which receives funding from the European Commission for the preparatory phase of the LHC High Luminosity Upgrade project. Informing the public is among the objectives of this EU-funded project. A simultaneous transmission of this meeting will be broadcast, available at the following address: http://webcast.cern.ch/

  5. [The application of radiological image in forensic medicine].

    PubMed

    Zhang, Ji-Zong; Che, Hong-Min; Xu, Li-Xiang

    2006-04-01

    Personal identification is an important work in forensic investigation included sex discrimination, age and stature estimation. Human identification depended on radiological image technique analysis is a practice and proper method in forensic science field. This paper intended to understand the advantage and defect by reviewed the employing of forensic radiology in forensic science field broadly and provide a reference to perfect the application of forensic radiology in forensic science field.

  6. Sample Based Unit Liter Dose Estimates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    JENSEN, L.

    The Tank Waste Characterization Program has taken many core samples, grab samples, and auger samples from the single-shell and double-shell tanks during the past 10 years. Consequently, the amount of sample data available has increased, both in terms of quantity of sample results and the number of tanks characterized. More and better data is available than when the current radiological and toxicological source terms used in the Basis for Interim Operation (BIO) (FDH 1999a) and the Final Safety Analysis Report (FSAR) (FDH 1999b) were developed. The Nuclear Safety and Licensing (NS and L) organization wants to use the new datamore » to upgrade the radiological and toxicological source terms used in the BIO and FSAR. The NS and L organization requested assistance in producing a statistically based process for developing the source terms. This report describes the statistical techniques used and the assumptions made to support the development of a new radiological source term for liquid and solid wastes stored in single-shell and double-shell tanks. The results given in this report are a revision to similar results given in an earlier version of the document (Jensen and Wilmarth 1999). The main difference between the results in this document and the earlier version is that the dose conversion factors (DCF) for converting {mu}Ci/g or {mu}Ci/L to Sv/L (sieverts per liter) have changed. There are now two DCFs, one based on ICRP-68 and one based on ICW-71 (Brevick 2000).« less

  7. Investigation of cloud/water vapor motion winds from geostationary satellite

    NASA Technical Reports Server (NTRS)

    1993-01-01

    This report summarizes the research work accomplished on the NASA grant contract NAG8-892 during 1992. Research goals of this contract are the following: to complete upgrades to the Cooperative Institute for Meteorological Satellite Studies (CIMSS) wind system procedures for assigning heights and incorporating first guess information; to evaluate these modifications using simulated tracer fields; to add an automated quality control system to minimize the need for manual editing, while maintaining product quality; and to benchmark the upgraded algorithm in tests with NMC and/or MSFC. Work progressed on all these tasks and is detailed. This work was done in collaboration with CIMSS NOAA/NESDIS scientists working on the operational winds software, so that NASA funded research can benefit NESDIS operational algorithms.

  8. Assembly and commissioning of a new SRF cryomodule for the ATLAS intensity upgrade

    NASA Astrophysics Data System (ADS)

    Conway, Z. A.; Barcikowski, A.; Cherry, G. L.; Fischer, R. L.; Fuerst, J. D.; Jansma, W. G.; Gerbick, S. M.; Kedzie, M. J.; Kelly, M. P.; Kim, S. H.; MacDonald, S. W. T.; Murphy, R. C.; Ostroumov, P. N.; Reid, T. C.; Shepard, K. W.

    2014-01-01

    The Argonne National Laboratory Physics Division is in the final stages of a major upgrade to the Argonne Tandem Linear Accelerator System national user facility, referred to as the intensity upgrade. The intensity upgrade project will substantially increase beam currents for experimenters working with the existing ATLAS stable and in-flight rare isotope beams and for the neutron-rich beams from the Californium Rare Isotope Breeder Upgrade. This project includes the replacement of three existing cryomodules, containing 18 superconducting accelerator cavities and 9 superconducting solenoids, with a single cryomodule with seven SC 72.75 MHz accelerator cavities optimized for ion velocities of 7.7% the speed of light and 4 SC solenoids all operating at 4.5 K. This presentation will report: how we minimized the heat load into the 4 K and 80 K coolant streams feeding the cryomodule, a comparison of the calculated and measured static heat loads at 80 K and the mechanical design of the vacuum vessel.

  9. ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.

    PubMed

    Vano, E; Faulkner, K

    2005-01-01

    The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protection for cardiologists performing fluoroscopically guided procedures, will be produced during 2005. This paper highlights some of the topics of the published reports, their relevance to European legislation on medical exposures and the importance of radiation protection research in underpinning the ICRP task groups' work in to producing these documents. It is also anticipated that the results, obtained in the cardiology work package of the European research project, will be used in the new document on radiation protection for cardiologists.

  10. The radiology digital dashboard: effects on report turnaround time.

    PubMed

    Morgan, Matthew B; Branstetter, Barton F; Lionetti, David M; Richardson, Jeremy S; Chang, Paul J

    2008-03-01

    As radiology departments transition to near-complete digital information management, work flows and their supporting informatics infrastructure are becoming increasingly complex. Digital dashboards can integrate separate computerized information systems and summarize key work flow metrics in real time to facilitate informed decision making. A PACS-integrated digital dashboard function designed to alert radiologists to their unsigned report queue status, coupled with an actionable link to the report signing application, resulted in a 24% reduction in the time between transcription and report finalization. The dashboard was well received by radiologists who reported high usage for signing reports. Further research is needed to identify and evaluate other potentially useful work flow metrics for inclusion in a radiology clinical dashboard.

  11. Common procedures and strategies for anaesthesia in interventional radiology.

    PubMed

    Landrigan-Ossar, Mary

    2015-08-01

    This review describes the range of cases now available in the interventional radiology suite and summarizes suggestions for their anaesthetic and perioperative management. The type and complexity of interventional radiology cases being performed increases from year to year. Anaesthesiologists' presence in interventional radiology is increasing in turn, due to increasingly ill patients and intricate procedures requiring more than local anaesthesia for well tolerated completion. The literature available describing this is largely written by radiologists, with little attention paid to anaesthetic considerations. Cases in interventional radiology are complex in terms of the logistics of working in an unfamiliar area, frequency of patient comorbidity and unfamiliar procedures. Ensuring familiarity with the variety of interventional radiology procedures and their periprocedure requirements can increase anaesthesiologists' comfort in interventional radiology.

  12. Early resident-to-resident physics education in diagnostic radiology.

    PubMed

    Kansagra, Akash P

    2014-01-01

    The revised ABR board certification process has updated the method by which diagnostic radiology residents are evaluated for competency in clinical radiologic physics. In this work, the author reports the successful design and implementation of a resident-taught physics course consisting of 5 weekly, hour-long lectures intended for incoming first-year radiology residents in their first month of training. To the author's knowledge, this is the first description of a course designed to provide a very early framework for ongoing physics education throughout residency without increasing the didactic burden on faculty members. Twenty-six first-year residents spanning 2 academic years took the course and reported subjective improvement in their knowledge (90%) and interest (75%) in imaging physics and a high level of satisfaction with the use of senior residents as physics educators. Based on the success of this course and the minimal resources required for implementation, this work may serve as a blueprint for other radiology residency programs seeking to develop revised physics curricula. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. The mandate and work of ICRP Committee 3 on radiological protection in medicine.

    PubMed

    Miller, D L; Martin, C J; Rehani, M M

    2018-01-01

    The mandate of Committee 3 of the International Commission on Radiological Protection (ICRP) is concerned with the protection of persons and unborn children when ionising radiation is used in medical diagnosis, therapy, and biomedical research. Protection in veterinary medicine has been newly added to the mandate. Committee 3 develops recommendations and guidance in these areas. The most recent documents published by ICRP that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (ICRP Publication 129) and 'Radiological protection in ion beam radiotherapy' (ICRP Publication 127). A report in cooperation with ICRP Committee 2 entitled 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (ICRP Publication 128) has also been published. 'Diagnostic reference levels in medical imaging' (ICRP Publication 135), published in 2017, provides specific advice on the setting and use of diagnostic reference levels for diagnostic and interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and multi-modality procedures. 'Occupational radiological protection in interventional procedures' was published in March 2018 as ICRP Publication 139. A document on radiological protection in therapy with radiopharmaceuticals is likely to be published in 2018. Work is in progress on several other topics, including appropriate use of effective dose in collaboration with the other ICRP committees, guidance for occupational radiological protection in brachytherapy, justification in medical imaging, and radiation doses to patients from radiopharmaceuticals (an update to ICRP Publication 128). Committee 3 is also considering the development of guidance on radiological protection in medicine related to individual radiosusceptibility, in collaboration with ICRP Committee 1.

  14. Project RavenCare: global multimedia telemedicine in Alaska

    NASA Astrophysics Data System (ADS)

    Tohme, Walid G.; Collmann, Jeff R.; Mun, Seong K.; Vastola, David J.

    1995-05-01

    Project RavenCare is a testbed for assessing the utility of teleradiology, telemedicine and electronic patient records systems for delivering health care to Native Alaskans in remote villages. It is being established as a joint project between the department of radiology at Georgetown University Medical Center and the Southeast Alaska Regional Health Corporation (SEARHC) in Sitka, Alaska. This initiative will establish a sustained routine clinical multimedia telemedicine support for a village clinic in Hoonah, Alaska and a regional hospital in Sitka. It will link the village clinic in Hoonah to Mt. Edgecumbe Hospital in Sitka. This regional hospital will in turn be linked to Georgetown University Hospital through the T1- VSAT (very small aperture terminal) of the NASA-ACTS (Advanced Communication Technology Satellite). Regional physicians in Hoonah lack support in providing relatively routine care in areas such as radiology and pathology. This project is an initial step in a general plan to upgrade telecommunications in the health care system of the Southeast Alaska region and will address aspects of two problems; limited communication between the village health clinics and the hospital and lack of subspecialty support for hospital-based physicians in Sitka.

  15. 40 CFR 35.2152 - Federal share.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... a primary, secondary, or advanced treatment facility or its interceptors, or infiltration/inflow... works required to train and upgrade waste treatment works operations and maintenance personnel may be up...

  16. 40 CFR 35.2152 - Federal share.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... a primary, secondary, or advanced treatment facility or its interceptors, or infiltration/inflow... works required to train and upgrade waste treatment works operations and maintenance personnel may be up...

  17. Gender and the radiology workforce: results of the 2014 ACR workforce survey.

    PubMed

    Bluth, Edward I; Bansal, Swati; Macura, Katarzyna J; Fielding, Julia; Truong, Hang

    2015-02-01

    As part of the 2014 ACR Human Resources Commission Workforce Survey, an assessment of the gender of the U.S. radiologist workforce was undertaken. Radiologist gender in relation to type of practice, work location, leadership roles, and full- versus part-time employment have not previously been assessed by this survey. The survey was completed by group leaders in radiology identified through the Practice of Radiology Environment Database. The response rate to the survey was 22%, representing 35% of all practicing radiologists. The survey found that 78% of the radiology workforce is male, and 22% female. Among the men, 58% work in private practice, and 18% in the academic/university environment; among women, percentages were 43% and 31%, respectively. Of all physician leads, 85% are men, 15% women. Of the full-time radiologists, 15% of men are practice leaders compared with 11% of women. Fewer women than men are in private practice. More women than men practice in academic/university environments. Among part-time radiologists, there are more men than women, but significantly more women work part time than men. Women are in the minority among practice leaders. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  18. Safety and efficacy for new techniques and imaging using new equipment to support European legislation: an EU coordination action.

    PubMed

    Zoetelief, J; Faulkner, K

    2008-01-01

    The past two decades have witnessed a technologically driven revolution in radiology. At the centre of these developments has been the use of computing. These developments have also been driven by the introduction of new detector and imaging devices in radiology and nuclear medicine, as well as the widespread application of computing techniques to enhance and extract information within the images acquired. Further advances have been introduced into digital practice. These technological developments, however, have not been matched by justification and optimisation studies to ensure that these new imaging devices and techniques are as effective as they might be, or performed at the lowest possible dose. The work programme of the SENTINEL Coordination Action was subdivided into eight work packages: functional performance and standards; efficacy and safety in digital radiology, dentistry and nuclear medicine, cardiology, interventional radiology, population screening/sensitive groups; justification, ethics and efficacy; good practice guidance and training; and project management. The intention of the work programme was to underwrite the safety, efficacy and ethical aspects of digital practice as well as to protect and add value to the equipment used in radiology.

  19. Working Group 5: Measurements technology and active experiments

    NASA Technical Reports Server (NTRS)

    Whipple, E.; Barfield, J. N.; Faelthammar, C.-G.; Feynman, J.; Quinn, J. N.; Roberts, W.; Stone, N.; Taylor, W. L.

    1986-01-01

    Technology issues identified by working groups 5 are listed. (1) New instruments are needed to upgrade the ability to measure plasma properties in space. (2) Facilities should be developed for conducting a broad range of plasma experiments in space. (3) The ability to predict plasma weather within magnetospheres should be improved and a capability to modify plasma weather developed. (4) Methods of control of plasma spacecraft and spacecraft plasma interference should be upgraded. (5) The space station laboratory facilities should be designed with attention to problems of flexibility to allow for future growth. These issues are discussed.

  20. Upgrading of the LGD cluster at JINR to support DLNP experiments

    NASA Astrophysics Data System (ADS)

    Bednyakov, I. V.; Dolbilov, A. G.; Ivanov, Yu. P.

    2017-01-01

    Since its construction in 2005, the Computing Cluster of the Dzhelepov Laboratory of Nuclear Problems has been mainly used to perform calculations (data analysis, simulation, etc.) for various scientific collaborations in which DLNP scientists take an active part. The Cluster also serves to train specialists. Much has changed in the past decades, and the necessity has arisen to upgrade the cluster, increasing its power and replacing the outdated equipment to maintain its reliability and modernity. In this work we describe the experience of performing this upgrading, which can be helpful for system administrators to put new equipment for clusters of this type into operation quickly and efficiently.

  1. Interactive Radiology teaching file system: the development of a MIRC-compliant and user-centered e-learning resource.

    PubMed

    dos-Santos, M; Fujino, A

    2012-01-01

    Radiology teaching usually employs a systematic and comprehensive set of medical images and related information. Databases with representative radiological images and documents are highly desirable and widely used in Radiology teaching programs. Currently, computer-based teaching file systems are widely used in Medicine and Radiology teaching as an educational resource. This work addresses a user-centered radiology electronic teaching file system as an instance of MIRC compliant medical image database. Such as a digital library, the clinical cases are available to access by using a web browser. The system has offered great opportunities to some Radiology residents interact with experts. This has been done by applying user-centered techniques and creating usage context-based tools in order to make available an interactive system.

  2. [Attitude survey of radiological technologists toward qualification acquisition of licentiate and degrees in Mie prefecture].

    PubMed

    Nakanishi, Satoshi; Kamigiri, Akira; Yamada, Tsuyoshi; Nanba, Kazuyoshi; Kitano, Tokio; Ito, Morihiro

    2011-01-01

    We conducted a questionnaire consciousness survey concerning qualification acquisition of licentiate and degrees among 406 radiological technologists working for medical facility in Mie Prefecture. We employed a mail-back questionnaire method. Then we analyzed relationships between progressive purpose and gender, age, and membership of the Japanese Society of Radiological Technology (JSRT). Results derived note the most common licentiate the participants wanted to acquire was the license concerning emergency medical care. On the other hand, they had limited interest in radiation therapy, nuclear medicine areas and the working environment measurement expert class I. In conclusion, the results of this study revealed the present condition that the necessity of qualification acquisition of licentiate is not recognized incorrectly. In addition, there was a mountain of issues for working radiological technologists to attend graduate school to get degrees. It is important to utilize the results of this study to enlighten their consciousness for limited interest licentiate, and interest them in attending graduate schools.

  3. INL@Work Radiological Search & Response Training

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turnage, Jennifer

    Dealing with radiological hazards is just part of the job for many INL scientists and engineers. Dodging bullets isn't. But some Department of Defense personnel may have to do both. INL employee Jennifer Turnage helps train soldiers in the art of detecting radiological and nuclear material. For more information about INL's research projects, visit http://www.facebook.com/idahonationallaboratory.

  4. INL@Work Radiological Search & Response Training

    ScienceCinema

    Turnage, Jennifer

    2017-12-13

    Dealing with radiological hazards is just part of the job for many INL scientists and engineers. Dodging bullets isn't. But some Department of Defense personnel may have to do both. INL employee Jennifer Turnage helps train soldiers in the art of detecting radiological and nuclear material. For more information about INL's research projects, visit http://www.facebook.com/idahonationallaboratory.

  5. Technology as an Occasion for Structuring: Evidence from Observations of CT Scanners and the Social Order of Radiology Departments.

    ERIC Educational Resources Information Center

    Barley, Stephen R.

    1986-01-01

    New technologies such as the CT scanner are challenging traditional role relations among radiology workers and may be altering the organizational and occupational structure of radiological work. This paper expands recent sociological thought by showing how identical CT scanners occasion similar structuring processes and created divergent forms of…

  6. Experiment Needs and Facilities Study Appendix A Transient Reactor Test Facility (TREAT) Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The TREAT Upgrade effort is designed to provide significant new capabilities to satisfy experiment requirements associated with key LMFBR Safety Issues. The upgrade consists of reactor-core modifications to supply the physics performance needed for the new experiments, an Advanced TREAT loop with size and thermal-hydraulics capabilities needed for the experiments, associated interface equipment for loop operations and handling, and facility modifications necessary to accommodate operations with the Loop. The costs and schedules of the tasks to be accomplished under the TREAT Upgrade project are summarized. Cost, including contingency, is about 10 million dollars (1976 dollars). A schedule for execution ofmore » 36 months has been established to provide the new capabilities in order to provide timely support of the LMFBR national effort. A key requirement for the facility modifications is that the reactor availability will not be interrupted for more than 12 weeks during the upgrade. The Advanced TREAT loop is the prototype for the STF small-bundle package loop. Modified TREAT fuel elements contain segments of graphite-matrix fuel with graded uranium loadings similar to those of STF. In addition, the TREAT upgrade provides for use of STF-like stainless steel-UO{sub 2} TREAT fuel for tests of fully enriched fuel bundles. This report will introduce the Upgrade study by presenting a brief description of the scope, performance capability, safety considerations, cost schedule, and development requirements. This work is followed by a "Design Description". Because greatly upgraded loop performance is central to the upgrade, a description is given of Advanced TREAT loop requirements prior to description of the loop concept. Performance requirements of the upgraded reactor system are given. An extensive discussion of the reactor physics calculations performed for the Upgrade concept study is provided. Adequate physics performance is essential for performance of experiments with the Advanced TREAT loop, and the stress placed on these calculations reflects this. Additional material on performance and safety is provided. Backup calculations on calculations of plutonium-release limits are described. Cost and schedule information for the Upgrade are presented.« less

  7. 2008 Mississippi Curriculum Framework: Postsecondary Radiologic Technology. (Program CIP: 51.0911 - Radiologic Technology/Science - Radiographer)

    ERIC Educational Resources Information Center

    Armstrong, David; Cochran, Timothy; Compton, Steve; Davis, Jennifer; Edgerton, Seena Shazowee; Kisner, Christie; Lewis, Judy; Sartin, Billie Faye; Shell, Deborah

    2008-01-01

    As the world economy continues to evolve, businesses and industries must adopt new practices and processes in order to survive. Quality and cost control, work teams and participatory management, and an infusion of technology are transforming the way people work and do business. Employees are now expected to read, write, and communicate…

  8. "It depends on us": employee perspective of healthy working conditions during continual reorganisations in a radiology department.

    PubMed

    Nilsson, Kerstin; Hertting, Anna; Petterson, Inga-Lill

    2009-01-01

    This study focuses on employees' experience of occupational health in a radiology department within a Swedish university hospital during years of continual reorganisations. This department's stable personal health trends in terms of self-rated mental health and sick-leave rates diverged from the general trends of deteriorating working conditions in the hospital. The aim was to identify dimensions of working conditions as positive determinants contributing to occupational health in a department of radiology undergoing continual reorganisations. Open-ended interviews with twelve employees were transcribed and analyzed using content-analysis. The employees experienced their new stimulating working tasks and a supporting organizational climate as important contributors to the healthy work condition. The positive effects of handling new technical challenges and the positive organisational climate, which were characterized by mutual trust, as well as work-confidence and respect for each others' competence, seem to function as buffering factors, balancing the negative effects of parallel downsizing and restructuring processes.

  9. Bio-Oil Deployment in the Home Heating Market

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butcher, T. A.; Trojanowski, R.; Mante, O.

    Distillate fuel oil is used in many stationary heating applications, predominantly in the Northeastern part of the United States. Total estimated non-transportation distillate use in 2014 was estimated to be 10.9 billion gallons. This study has focused on potentially displacing part of this petroleum use with biofuel derived from woody biomass. The fuel production route considered is pyrolysis which creates a liquid fuel high in oxygen, organic acids, and water. While this fuel can be used in stationary applications without significant further processing, to do so would require significant upgrades in current heating equipment. Alternatively this raw pyrolysis oil canmore » be upgraded through catalytic hydrogenation to produce a bio-oil with near-negligible oxygen, water, and acidity. The focus of this work has been exploration of such upgraded fuels. The quality of upgraded fuels is affected by process conditions and there is a cost /quality tradeoff.« less

  10. Relativity Screens for Misvalued Medical Services: Impact on Noninvasive Diagnostic Radiology.

    PubMed

    Rosenkrantz, Andrew B; Silva, Ezequiel; Hawkins, C Matthew

    2017-11-01

    In 2006, the AMA/Specialty Society Relative Value Scale Update Committee (RUC) introduced ongoing relativity screens to identify potentially misvalued medical services for payment adjustments. We assess the impact of these screens upon the valuation of noninvasive diagnostic radiology services. Data regarding relativity screens and relative value unit (RVU) changes were obtained from the 2016 AMA Relativity Assessment Status Report. All global codes in the 2016 Medicare Physician Fee Schedule with associated work RVUs were classified as noninvasive diagnostic radiology services versus remaining services. The frequency of having ever undergone a screen was compared between the two groups. Screened radiology codes were further evaluated regarding the RVU impact of subsequent revaluation. Of noninvasive diagnostic radiology codes, 46.0% (201 of 437) were screened versus 22.2% (1,460 of 6,575) of remaining codes (P < .001). Most common screens for which radiology codes were identified as potentially misvalued were (1) high expenditures (27.5%) and (2) high utilization (25.6%). The modality and body region most likely to be identified in a screen were CT (82.1%) and breast (90.9%), respectively. Among screened radiology codes, work RVUs, practice expense RVUs, and nonfacility total RVUs decreased in 20.3%, 65.9%, and 75.3%, respectively. All screened CT, MRI, brain, and spine codes exhibited decreased total RVUs. Policymakers' ongoing search for potentially misvalued medical services has disproportionately impacted noninvasive diagnostic radiology services, risking the introduction of unintended or artificial shifts in physician practice. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. A scalable and continuous-upgradable optical wireless and wired convergent access network.

    PubMed

    Sung, J Y; Cheng, K T; Chow, C W; Yeh, C H; Pan, C-L

    2014-06-02

    In this work, a scalable and continuous upgradable convergent optical access network is proposed. By using a multi-wavelength coherent comb source and a programmable waveshaper at the central office (CO), optical millimeter-wave (mm-wave) signals of different frequencies (from baseband to > 100 GHz) can be generated. Hence, it provides a scalable and continuous upgradable solution for end-user who needs 60 GHz wireless services now and > 100 GHz wireless services in the future. During the upgrade, user only needs to upgrade their optical networking unit (ONU). A programmable waveshaper is used to select the suitable optical tones with wavelength separation equals to the desired mm-wave frequency; while the CO remains intact. The centralized characteristics of the proposed system can easily add any new service and end-user. The centralized control of the wavelength makes the system more stable. Wired data rate of 17.45 Gb/s and w-band wireless data rate up to 3.36 Gb/s were demonstrated after transmission over 40 km of single-mode fiber (SMF).

  12. Upgrade of a GEP50 robot control system

    NASA Astrophysics Data System (ADS)

    Alounai, Ali T.; Gharsalli, Imed

    2000-03-01

    Recently the ASL at Tennessee Technological University was donated a GEP50 welder. The welding is done via off line point-to-point teaching. A state of the art robot was needed for research but because money was not available to purchase such an expensive item. It was therefore decided to upgrade the GEP50 control system to make the welder a multitasking robot. The robot has five degrees of freedom can be sufficient to pursue some research in robotics control. The problem was that the control system of the welder is limited to point-to-point control, using off-line teaching. To make the GEP50 a multitasking robot that can be controlled using different control strategies, the existing control system of the welder had to be replaced. The upgrade turned to be a low cost operation. This robot is currently in sue to test different advanced control strategies in the ASL. This work discusses all the steps and tasks undertaken during the upgrade operation. The hardware and software required or the upgrade are provided in this paper. The newly developed control system has been implemented and tested successfully.

  13. Deployment of IPv6-only CPU resources at WLCG sites

    NASA Astrophysics Data System (ADS)

    Babik, M.; Chudoba, J.; Dewhurst, A.; Finnern, T.; Froy, T.; Grigoras, C.; Hafeez, K.; Hoeft, B.; Idiculla, T.; Kelsey, D. P.; López Muñoz, F.; Martelli, E.; Nandakumar, R.; Ohrenberg, K.; Prelz, F.; Rand, D.; Sciabà, A.; Tigerstedt, U.; Traynor, D.

    2017-10-01

    The fraction of Internet traffic carried over IPv6 continues to grow rapidly. IPv6 support from network hardware vendors and carriers is pervasive and becoming mature. A network infrastructure upgrade often offers sites an excellent window of opportunity to configure and enable IPv6. There is a significant overhead when setting up and maintaining dual-stack machines, so where possible sites would like to upgrade their services directly to IPv6 only. In doing so, they are also expediting the transition process towards its desired completion. While the LHC experiments accept there is a need to move to IPv6, it is currently not directly affecting their work. Sites are unwilling to upgrade if they will be unable to run LHC experiment workflows. This has resulted in a very slow uptake of IPv6 from WLCG sites. For several years the HEPiX IPv6 Working Group has been testing a range of WLCG services to ensure they are IPv6 compliant. Several sites are now running many of their services as dual-stack. The working group, driven by the requirements of the LHC VOs to be able to use IPv6-only opportunistic resources, continues to encourage wider deployment of dual-stack services to make the use of such IPv6-only clients viable. This paper presents the working group’s plan and progress so far to allow sites to deploy IPv6-only CPU resources. This includes making experiment central services dual-stack as well as a number of storage services. The monitoring, accounting and information services that are used by jobs also need to be upgraded. Finally the VO testing that has taken place on hosts connected via IPv6-only is reported.

  14. Pyrolysis of Woody Residue Feedstocks: Upgrading of Bio-Oils from Mountain-Pine-Beetle-Killed Trees and Hog Fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zacher, Alan H.; Elliott, Douglas C.; Olarte, Mariefel V.

    Liquid transportation fuel blend-stocks were produced by pyrolysis and catalytic upgrading of woody residue biomass. Mountain pine beetle killed wood and hog fuel from a saw mill were pyrolyzed in a 1 kg/h fluidized bed reactor and subsequently upgraded to hydrocarbons in a continuous fixed bed hydrotreater. Upgrading was performed by catalytic hydrotreatment in a two-stage bed at 170°C and 405°C with a per bed LHSV between 0.17 and 0.19. The overall yields from biomass to upgraded fuel were similar for both feeds: 24-25% despite the differences in bio-oil (intermediate) mass yield. Pyrolysis bio-oil mass yield was 61% from MPBKmore » wood, and subsequent upgrading of the bio-oil gave an average mass yield of 41% to liquid fuel blend stocks. Hydrogen was consumed at an average of 0.042g/g of bio-oil fed, with final oxygen content in the product fuel ranging from 0.31% to 1.58% over the course of the test. Comparatively for hog fuel, pyrolysis bio-oil mass yield was lower at 54% due to inorganics in the biomass, but subsequent upgrading of that bio-oil had an average mass yield of 45% to liquid fuel, resulting in a similar final mass yield to fuel compared to the cleaner MPBK wood. Hydrogen consumption for the hog fuel upgrading averaged 0.041 g/g of bio-oil fed, and the final oxygen content of the product fuel ranged from 0.09% to 2.4% over the run. While it was confirmed that inorganic laded biomass yields less bio-oil, this work demonstrated that the resultant bio-oil can be upgraded to hydrocarbons at a higher yield than bio-oil from clean wood. Thus the final hydrocarbon yield from clean or residue biomass pyrolysis/upgrading was similar.« less

  15. The 64 meter antenna operation at K sub A band

    NASA Technical Reports Server (NTRS)

    Potter, P. D.

    1980-01-01

    The future potential of the 32 GHz K sub A band frequency region to planetary exploration, and the expected performance of the 64 m antenna network at 32 GHz is addressed. A modest level of noninterference upgrade work is assumed to achieve reasonable antenna aperture efficiency and alleviate antenna pointing difficulties. Electronic compensation of antenna aperture phasing errors is briefly considered as an alternative to the physical upgrade.

  16. Operational present status and reliability analysis of the upgraded EAST cryogenic system

    NASA Astrophysics Data System (ADS)

    Zhou, Z. W.; Y Zhang, Q.; Lu, X. F.; Hu, L. B.; Zhu, P.

    2017-12-01

    Since the first commissioning in 2005, the cryogenic system for EAST (Experimental Advanced Superconducting Tokamak) has been cooled down and warmed up for thirteen experimental campaigns. In order to promote the refrigeration efficiencies and reliability, the EAST cryogenic system was upgraded gradually with new helium screw compressors and new dynamic gas bearing helium turbine expanders with eddy current brake to improve the original poor mechanical and operational performance from 2012 to 2015. Then the totally upgraded cryogenic system was put into operation in the eleventh cool-down experiment, and has been operated for the latest several experimental campaigns. The upgraded system has successfully coped with various normal operational modes during cool-down and 4.5 K steady-state operation under pulsed heat load from the tokamak as well as the abnormal fault modes including turbines protection stop. In this paper, the upgraded EAST cryogenic system including its functional analysis and new cryogenic control networks will be presented in detail. Also, its operational present status in the latest cool-down experiments will be presented and the system reliability will be analyzed, which shows a high reliability and low fault rate after upgrade. In the end, some future necessary work to meet the higher reliability requirement for future uninterrupted long-term experimental operation will also be proposed.

  17. Core curriculum for medical physicists in radiology. Recommendations from an EFOMP/ESR working group.

    PubMed

    Geleijns, Jacob; Breatnach, Eamann; Cantera, Alfonso Calzado; Damilakis, John; Dendy, Philip; Evans, Anthony; Faulkner, Keith; Padovani, Renato; Van Der Putten, Wil; Schad, Lothar; Wirestam, Ronnie; Eudaldo, Teresa

    2012-06-01

    Some years ago it was decided that a European curriculum should be developed for medical physicists professionally engaged in the support of clinical diagnostic imaging departments. With this in mind, EFOMP (European Federation of Organisations for Medical Physics) in association with ESR (European Society of Radiology) nominated an expert working group. This curriculum is now to hand. The curriculum is intended to promote best patient care in radiology departments through the harmonization of education and training of medical physicists to a high standard in diagnostic radiology. It is recommended that a medical physicist working in a radiology department should have an advanced level of professional expertise in X-ray imaging, and additionally, depending on local availability, should acquire knowledge and competencies in overseeing ultrasound imaging, nuclear medicine, and MRI technology. By demonstrating training to a standardized curriculum, medical physicists throughout Europe will enhance their mobility, while maintaining local high standards of medical physics expertise. This document also provides the basis for improved implementation of articles in the European medical exposure directives related to the medical physics expert. The curriculum is divided into three main sections: The first deals with general competencies in the principles of medical physics. The second section describes specific knowledge and skills required for a medical physicist (medical physics expert) to operate clinically in a department of diagnostic radiology. The final section outlines research skills that are also considered to be necessary and appropriate competencies in a career as medical physicist.

  18. Gun Shot Wound to the Chest of a Military Working Dog

    DTIC Science & Technology

    2009-06-01

    special care ought to be taken when either human or dog is on isolation precautions. Also, animals without airway compromise should be muzzled , as...Gun Shot Wound to Chest of Military Working Dog Military Medicine Radiology Corner, Volume 174, June, 2009 Radiology Corner Gun Shot Wound to...the Chest of a Military Working Dog Guarantor: 2LT Meghan Galer, MSC, USA1 Contributors: 2LT Meghan Galer, MSC, USA1; Donna Magid, MD, MEd2; Les

  19. Software tools for interactive instruction in radiologic anatomy.

    PubMed

    Alvarez, Antonio; Gold, Garry E; Tobin, Brian; Desser, Terry S

    2006-04-01

    To promote active learning in an introductory Radiologic Anatomy course through the use of computer-based exercises. DICOM datasets from our hospital PACS system were transferred to a networked cluster of desktop computers in a medical school classroom. Medical students in the Radiologic Anatomy course were divided into four small groups and assigned to work on a clinical case for 45 minutes. The groups used iPACS viewer software, a free DICOM viewer, to view images and annotate anatomic structures. The classroom instructor monitored and displayed each group's work sequentially on the master screen by running SynchronEyes, a software tool for controlling PC desktops remotely. Students were able to execute the assigned tasks using the iPACS software with minimal oversight or instruction. Course instructors displayed each group's work on the main display screen of the classroom as the students presented the rationale for their decisions. The interactive component of the course received high ratings from the students and overall course ratings were higher than in prior years when the course was given solely in lecture format. DICOM viewing software is an excellent tool for enabling students to learn radiologic anatomy from real-life clinical datasets. Interactive exercises performed in groups can be powerful tools for stimulating students to learn radiologic anatomy.

  20. The upgraded Large Plasma Device, a machine for studying frontier basic plasma physics.

    PubMed

    Gekelman, W; Pribyl, P; Lucky, Z; Drandell, M; Leneman, D; Maggs, J; Vincena, S; Van Compernolle, B; Tripathi, S K P; Morales, G; Carter, T A; Wang, Y; DeHaas, T

    2016-02-01

    In 1991 a manuscript describing an instrument for studying magnetized plasmas was published in this journal. The Large Plasma Device (LAPD) was upgraded in 2001 and has become a national user facility for the study of basic plasma physics. The upgrade as well as diagnostics introduced since then has significantly changed the capabilities of the device. All references to the machine still quote the original RSI paper, which at this time is not appropriate. In this work, the properties of the updated LAPD are presented. The strategy of the machine construction, the available diagnostics, the parameters available for experiments, as well as illustrations of several experiments are presented here.

  1. The key image and case log application: new radiology software for teaching file creation and case logging that incorporates elements of a social network.

    PubMed

    Rowe, Steven P; Siddiqui, Adeel; Bonekamp, David

    2014-07-01

    To create novel radiology key image software that is easy to use for novice users, incorporates elements adapted from social networking Web sites, facilitates resident and fellow education, and can serve as the engine for departmental sharing of interesting cases and follow-up studies. Using open-source programming languages and software, radiology key image software (the key image and case log application, KICLA) was developed. This system uses a lightweight interface with the institutional picture archiving and communications systems and enables the storage of key images, image series, and cine clips. It was designed to operate with minimal disruption to the radiologists' daily workflow. Many features of the user interface have been inspired by social networking Web sites, including image organization into private or public folders, flexible sharing with other users, and integration of departmental teaching files into the system. We also review the performance, usage, and acceptance of this novel system. KICLA was implemented at our institution and achieved widespread popularity among radiologists. A large number of key images have been transmitted to the system since it became available. After this early experience period, the most commonly encountered radiologic modalities are represented. A survey distributed to users revealed that most of the respondents found the system easy to use (89%) and fast at allowing them to record interesting cases (100%). Hundred percent of respondents also stated that they would recommend a system such as KICLA to their colleagues. The system described herein represents a significant upgrade to the Digital Imaging and Communications in Medicine teaching file paradigm with efforts made to maximize its ease of use and inclusion of characteristics inspired by social networking Web sites that allow the system additional functionality such as individual case logging. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  2. Upgrade of the TITAN EBIT High Voltage Operation

    NASA Astrophysics Data System (ADS)

    Foster, Matt; Titan Collaboration

    2016-09-01

    TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) is a setup dedicated to highly precise mass measurements of short-lived isotopes down to 10ms. TITAN's Electron Beam Ion Trap (EBIT) is a charge breeder integrated into the setup to perform in-trap decay spectroscopy of highly charged ions and increase the precision of mass measurements. In its previous configuration TITAN's EBIT could not fulfil its maximum design specification due to high voltage safety restrictions, limiting its obtainable charge states. A recently completed upgrade of the high voltage operation that will allow the EBIT to fulfil its design specification and achieve higher charge states for heavier species is undergoing preliminary tests with stable beam. Simulations were performed to optimise the injection and extraction efficiency at high voltage and initial tests have involved using a Ge detector to identify x-rays produced by charge breeding stable ions. Future work comprises exploring electron capture rates of Ne-, He- and H-like charge states of 64Cu and higher masses, which were not previously accessible. The function of the EBIT within the TITAN setup, the work carried out on the upgrade thus far and its scope for future work will be presented.

  3. Fluor Hanford ALARA Center is a D and D Resource

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waggoner, L.O.

    2008-01-15

    The mission at the Hanford Nuclear Reservation changed when the last reactor plant was shut down in 1989 and work was started to place all the facilities in a safe condition and begin decontamination, deactivation, decommissioning, and demolition (D and D). These facilities consisted of old shutdown reactor plants, spent fuel pools, processing facilities, and 177 underground tanks containing 53 million gallons of highly radioactive and toxic liquids and sludge. New skills were needed by the workforce to accomplish this mission. By 1995, workers were in the process of getting the facilities in a safe condition and it became obviousmore » improvements were needed in their tools, equipment and work practices. The Hanford ALARA Program looked good on paper, but did little to help contractors that were working in the field. The Radiological Control Director decided that the ALARA program needed to be upgraded and a significant improvement could be made if workers had a place they could visit that had samples of the latest technology and could talk to experienced personnel who have had success doing D and D work. Two senior health physics personnel who had many years experience in doing radiological work were chosen to obtain tools and equipment from vendors and find a location centrally located on the Hanford site. Vendors were asked to loan their latest tools and equipment for display. Most vendors responded and the Hanford ALARA Center of Technology opened on October 1, 1996. Today, the ALARA Center includes a classroom for conducting training and a mockup area with gloveboxes. Two large rooms have a containment tent, several glove bags, samples of fixatives/expandable foam, coating displays, protective clothing, heat stress technology, cutting tools, HEPA filtered vacuums, ventilation units, pumps, hydraulic wrenches, communications equipment, shears, nibblers, shrouded tooling, and several examples of innovative tools developed by the Hanford facilities. See Figures I and II. The ALARA Center staff routinely researches and tests new technology, sponsor vendor demonstrations, and redistribute tools, equipment and temporary shielding that may not be needed at one facility to another facility that needs it. The ALARA Center staff learns about new technology in several ways. This includes past radiological work experience, interaction with vendors, lessons learned, networking with other DOE sites, visits to the Hanford Technical Library, attendance at off-site conferences and ALARA Workshops. Personnel that contact the ALARA Center for assistance report positive results when they implement the tools, equipment and work practices recommended by the ALARA Center staff. This has translated to reduced exposure for workers and reduced the risk of contamination spread. For example: using a hydraulic shear on one job saved 16 Rem of exposure that would have been received if workers had used saws-all tools to cut piping in twenty-nine locations. Currently, the ALARA Center staff is emphasizing D and D techniques on size-reducing materials, decontamination techniques, use of remote tools/video equipment, capture ventilation, fixatives, using containments and how to find lessons learned. The ALARA Center staff issues a weekly report that discusses their interaction with the workforce and any new work practices, tools and equipment being used by the Hanford contractors. Distribution of this weekly report is to about 130 personnel on site and 90 personnel off site. This effectively spreads the word about ALARA throughout the DOE Complex. DOE EM-23, in conjunction with the D and D and Environmental Restoration work group of the Energy Facility Contractors Organization (EFCOG) established the Hanford ALARA Center as the D and D Hotline for companies who have questions about how D and D work is accomplished. The ALARA Center has become a resource to the nuclear industry and routinely helps contractors at other DOE Sites, power reactors, DOD sites, and sites in England, Europe and Indonesia. Other ALARA Centers are located at the Savannah River Site and Los Alamos National Lab.« less

  4. Stress management for the radiologic technologist.

    PubMed

    Romano, Jeannine M

    2012-01-01

    Changes in technology in the radiology department and an emphasis on multitasking can lead to stress and burnout, along with the potential for medical errors. A shift in viewpoint and exercises in self-evaluation can help radiologic technologists learn to manage change in a positive manner. Learning to approach change through a series of transitions and positive steps can reduce stress at work and at home.

  5. Preparing a business justification for going electronic.

    PubMed

    Ortiz, A Orlando; Luyckx, Michael P

    2002-01-01

    Exponential advances in the technology sector and computer industry have benefited the science and practice of radiology. Modalities such as digital radiography, computed radiography, computed tomography, magnetic resonance imaging, ultrasound, digital angiography, and gamma cameras are all capable of producing DICOM compliant images. Text can likewise be acquired using voice recognition technology (VRT) and efficiently rendered into a digital format. All of these digital data sets can subsequently be transferred over a network between machines for display and further manipulation on workstations. Large capacity archiving units are required to store these voluminous data sets. The enterprise components of radiology departments and imaging centers--radiology information systems (RIS) and picture archiving and communications systems (PACS)--have thus undergone a transition from hardcopy to softcopy. When preparing to make transition to a digital environment, the first step is introspective. A detailed SWOT (strengths, weaknesses, opportunities and threats) analysis, with a focus on the status of "electronic preparedness," ensues. The next step in the strategic planning process is to formulate responses to the following questions: Will this technology acquisition provide sufficient value to my organization to justify the expense? Is there a true need for the new technology? What issues or problems does this technology address? What customer needs will this technology satisfy today and tomorrow? How will the organization's shareholders benefit from this technology? The answers to these questions and the questions that they in turn generate will stimulate the strategic planning process to define demands, investigate technology and investment options, identify resources and set goals. The mission of your radiology center will determine what you will demand from the electronic environment. All radiology practices must address the demand of clinical service. Additional demands based on your mission may include education and research. The investigation of options is probably the most time consuming portion of the analysis. It is in this stage where the system architecture is drafted. Important contributions must be solicited from your information technology division, radiologists and other physicians, hospital administration and any other service where the use of imaging technology information is required and beneficial. Vendors and consultants can be extremely valuable in generating workflow diagrams, which include imaging acquisition components and imaging display components. A request for proposal (RFP) may facilitate this step. A detailed inventory of imaging equipment, imaging equipment locations and use, imaging equipment DICOM compatibility, imaging equipment upgrade requirements, reading locations and user locations must be obtained and confirmed. It is a good idea to take a careful inventory of your resources during the process of investigating system architecture and financial options. An often-ignored issue is the human resource allocation that is required to implement, maintain and upgrade the system. These costs must be estimated and included in the financial analysis. Further, to predict the finances of your operation in the future, a solid understanding of your center's historical financial data is required. This will enable you to make legitimate and reasonable financial calculations using incremental volumes. The radiology center must formulate and articulate discrete clinical and business goals for the transition to a digital environment that are consistent with the institutional or enterprise mission. Once goals are set, it is possible to generate a strategic plan. It is necessary to establish individual accountability for all aspects of the planning and implementation process. A realistic timetable should be implemented. Keep in mind that this is a dynamic process; technology is rapidly changing, as are clinical service demands and regulatory initiatives. It is therefore prudent to monitor the process, make appropriate revisions when necessary and address contingencies as they arise.

  6. A new 3D viewer as an interface between the ASDEX Upgrade CAD models and data from plasma modelling and experiment

    NASA Astrophysics Data System (ADS)

    Lunt, T.; Fuchs, J. C.; Mank, K.; Feng, Y.; Brochard, F.; Herrmann, A.; Rohde, V.; Endstrasser, N.; ASDEX Upgrade Team

    2010-11-01

    A generally available and easy-to-use viewer for the simultaneous visualisation of the ASDEX Upgrade vacuum vessel computer aided design models, diagnostics and magnetic geometry, solutions of 3D plasma simulation codes and 2D camera images was developed. Here we report on the working principle of this software and give several examples of its technical and scientific application.

  7. What is the relation between number of sessions worked and productivity of radiologists-a pilot study?

    PubMed

    Khan, Shah H M; Hedges, William P

    2016-04-01

    Increasing workloads and the current austerity measures are putting UK radiology departments under considerable stress. We need to look at the most efficient ways to manage radiology departments in order to cope with increasing demand. Consequently, a system is needed that can compare productivity between radiologists with different jobs. We measured workload in a UK radiology department and compared the productivities of consultants working different numbers of sessions, which are called programmed activities (PAs), to identify the optimal job plan structure for reporting productivity. Reporting data was gathered from electronic records for 14 consultants working different numbers of PA during the period April 2010-March 2011. These were converted into relative value unit (RVU) scores using a modified RCSI RVU system. Crude and net workloads were calculated for each consultant by dividing their total RVU score by the number of PAs they were contracted for and how many they spent reporting. The consultants reported 118,001 imaging studies. There was statistically significant variation in productivity between consultants working different numbers of PAs on χ (2) analysis (p < 0.05). Consultants working 12 PAs were more productive than consultants working 11 PAs, with net workloads of 7636 RVU/PA/year versus net 6146 RVU/PA/year, p < 0.05. Although UK consultants working 12 PAs per week are more productive than their colleagues, the reasons why are unclear. We have identified a method that can be developed further to identify efficient working practices in UK radiology departments. However, a UK-specific RVU system would make this productivity analysis more accurate.

  8. A presentation system for just-in-time learning in radiology.

    PubMed

    Kahn, Charles E; Santos, Amadeu; Thao, Cheng; Rock, Jayson J; Nagy, Paul G; Ehlers, Kevin C

    2007-03-01

    There is growing interest in bringing medical educational materials to the point of care. We sought to develop a system for just-in-time learning in radiology. A database of 34 learning modules was derived from previously published journal articles. Learning objectives were specified for each module, and multiple-choice test items were created. A web-based system-called TEMPO-was developed to allow radiologists to select and view the learning modules. Web services were used to exchange clinical context information between TEMPO and the simulated radiology work station. Preliminary evaluation was conducted using the System Usability Scale (SUS) questionnaire. TEMPO identified learning modules that were relevant to the age, sex, imaging modality, and body part or organ system of the patient being viewed by the radiologist on the simulated clinical work station. Users expressed a high degree of satisfaction with the system's design and user interface. TEMPO enables just-in-time learning in radiology, and can be extended to create a fully functional learning management system for point-of-care learning in radiology.

  9. Modification of the Electromagnetic Levitator (EML) Hardware

    NASA Technical Reports Server (NTRS)

    Frost, R. T.

    1985-01-01

    The goals of this project are: (1) to study the upgrade requirements and approaches needed for incorporation of an Electromagnetic Levitator (EML) into the shuttle orbiter, (2) to work with members of the Electromagnetic Containerless Processing science working group (SWG) to define future experiments for the EML, and (3) to assist these investigators in further development of ground-based experiment techniques to the limits possible in the terrestrial gravitational environment. Present work is directed toward: (1) upgrading the EML flight apparatus to meet requirements of safety and integration interfaces with the MSL orbiter carrier, (2) development of new experiment components required to carry out approved experiments in undercooled solidification and associated fluid flow studies directed by MIT, and (3) construction, test, qualification and integration assistance for the EML MSL flight package.

  10. Thyroid cancer and employment as a radiologic technologist.

    PubMed

    Zabel, Erik W; Alexander, Bruce H; Mongin, Steven J; Doody, Michele M; Sigurdson, Alice J; Linet, Martha S; Freedman, D Michal; Hauptmann, Michael; Mabuchi, Kiyohiko; Ron, Elaine

    2006-10-15

    The association between chronic occupational ionizing radiation exposure in the medical field and thyroid cancer is not well characterized. Thyroid cancer incidence was ascertained for 2 periods in a cohort of radiologic technologists certified for a minimum 2 years and enumerated in 1983: (i) cases identified prospectively in 73,080 radiologic technologists who were free of thyroid cancer at the baseline survey and completed a second questionnaire a decade later (N = 121), and (ii) cases occurring prior to cohort enumeration among 90,245 technologists who completed the baseline survey and were thyroid cancer free 2 years after certification (N = 148). Survival analyses estimated risks associated with employment as a radiologic technologist, including duration of employment, period of employment, types of procedures and work practices. The only occupational history characteristic associated with prospectively identified thyroid cancer was a history of holding patients for X-ray procedures at least 50 times (HR = 1.47, 95% CI = 1.01-2.15). Total years worked as a radiologic technologist, years performing diagnostic, therapeutic, and nuclear medicine procedures, employment under age 20 and calendar period of first employment were not associated with thyroid cancer risk. Risk of thyroid cancers diagnosed before the baseline questionnaire was inversely associated with decade first employed as a technologist, and was elevated, albeit imprecisely, among those working more than 5 years prior to 1950 (HR = 3.04, 95% CI = 1.01-10.78). These data provide modest evidence of an association between employment as a radiologic technologist and thyroid cancer risk; however, the findings require confirmation with more accurate exposure models. Copyright 2006 Wiley-Liss, Inc.

  11. A portrait of interventional radiologists in the United States.

    PubMed

    Sunshine, Jonathan H; Lewis, Rebecca S; Bhargavan, Mythreyi

    2005-11-01

    In recognition of the emergence of interventional radiology as an important "new component of...radiology," the objective of our study was to provide an extensive and detailed portrait of interventional radiologists, their professional activities, and the practices in which they work. We tabulated data from the American College of Radiology's 2003 Survey of Radiologists, a stratified random-sample survey that oversampled interventionalists and achieved a 63% response rate with a total of 1,924 responses. Responses were weighted to make them representative of all radiologists in the United States. We compared information about interventionalists with that for other radiologists. Depending on the definition of who is an interventionalist, 8.5-11.5% of radiologists are interventionalists. By most definitions, only slightly under half of interventionalists spend 70% or more of their clinical work time performing interventional procedures. Interventionalists work, on average, 56-58 hr weekly, a few hours longer than other radiologists. The average interventionalist performs procedures in five of the seven categories of procedures into which we divided interventional radiology, compared with one or two categories for other radiologists. The average interventionalist performs procedures in five of the seven broad categories (such as MRI, CT, and nuclear medicine) into which we divided all of radiology, much the same breadth of practice as other subspecialists and also as nonsubspecialists. Interventionalists have become a sizable group within radiology. They are in some ways like other radiologists and in other ways different, but they do not spend as much of their time in their subspecialty as some assume and, overall, are not as different.

  12. DR AVRAM JOZEF VINAVER (1862-1915) - PIONEER OF RADIOLOGY IN SERBIA.

    PubMed

    Babić, Rade Radomir; Stanković Babić, Gordana

    2015-01-01

    Dr Abraham Joseph Vinaver (1862-1915), a Jew from Poland, was a pioneer of radiology in Serbia. He graduated from the Faculty of Medicine in Warsaw (1887), but lived and worked in abac (the Kingdom of Serbia) since 1890. Dr Abraham Joseph Vinarev - Career Development. He procured the first X-ray machine and developed radiological service in Sabac five years after the discovery of X-rays. These were the beginnings of radiology in Serbia. He introduced the application of artesian wells. Dr Abraham Joseph Vinarev - a Participant at the First Congress of Serbian Physicians and Naturalists, Belgrade 1904. "The diagnostic importance of X-rays in lung disease, especially in initial tuberculosis" and "Five Years of Treatment by X-Ray Machines" were the first works in the field of radiology in Serbia by this author. Dr Abraham Joseph Vinaver - Reserve Medical Officer in the Serbian Army. During the Balkan Wars, he was a volunteer with the rank of major engaged in military corps and he participated in the First World War as well. He died of malaria in 1915 in Gevgelija. "Dr Avram Vinaver"- Stanislav Vinarev. His dedication to work during the typhus epidemics was put into verses of a poem by his son Stanislav Vinarev. Dr Avram Vinaver Joseph was a noble man with a great heart, who selflessly sacrificed himself for the Serbian people and Serbia. He gave his contribution to the development of health services in Serbia, both in peacetime and wartime conditions. Dr Abraham Joseph Vinaver laid the foundations for today's radiology in Serbia.

  13. Knee degeneration in concrete reinforcement workers.

    PubMed Central

    Wickström, G; Hänninen, K; Mattsson, T; Niskanen, T; Riihimäki, H; Waris, P; Zitting, A

    1983-01-01

    The loads on the knees in concrete reinforcement work and maintenance painting were analysed on eight construction work sites. A total of 352 reinforcement workers and 231 painters. Finnish men aged 20-64, were clinically and radiologically examined to determine the condition of the knee joints in active workers. The loads on the knees and the occurrence of minor injuries and accidents were higher in reinforcement work than in painting, but the occurrence of symptoms, clinical signs, and radiological findings was equally common in both groups. Reinforcement work seemed to provoke more symptoms from degenerated knees than painting. PMID:6830721

  14. Competency-Based Education and the World of Work.

    ERIC Educational Resources Information Center

    Huff, Sheila M.

    Some issues in connection with competency-based education (CBE) and the world of work discussed by the author include the relevance of CBE programs to work, the changing attitudes of students and young workers toward work, "credentialism" or the continual upgrading of educational requirements for employment, underemployment and CBE, and others.…

  15. Use of personal digital assistants in diagnostic radiology resident education.

    PubMed

    Nishino, Mizuki; Busch, James M; Wei, Jesse; Barbaras, Larry; Yam, Chun-Shan; Hatabu, Hiroto

    2004-10-01

    Personal digital assistants (PDAs) are gaining widespread use in the medical community. We introduced a PDA-based mobile system that provides departmental and educational information with a seamless connection to the intranet. The objective of this study is to determine the impact a PDA has on educational resources (learning or data reference) brought to work and used at home by a radiology resident based on user surveys. Survey was performed on 32 radiology residents in our department before and 6 months after the release of the PDA-based system. We assessed the changes in (1) sources of learning at home and at work, and in (2) data reference. The second survey also evaluated the usefulness of each component of the system. After the release of the PDA-based mobile system, the use of "digital books and references" as data references and educational resources that were brought to work every day significantly increased (P = .016, P < .0001, respectively). "Traditional books and references" remained the "most useful source in learning radiology"; however, "digital books and references" increased as the residents' first choice from 0% to 16% within 6 months of introducing the package (P = .125). The introduction of a PDA-based system consisting of educational and departmental information had a statistically significant impact in increasing the use of digitized information in radiology resident education.

  16. Radiology preparedness in ebola virus disease: guidelines and challenges for disinfection of medical imaging equipment for the protection of staff and patients.

    PubMed

    Mollura, Daniel J; Palmore, Tara N; Folio, Les R; Bluemke, David A

    2015-05-01

    The overlap of early Ebola virus disease (EVD) symptoms (eg, fever, headache, abdominal pain, diarrhea, emesis, and fatigue) with symptoms of other more common travel-related diseases (eg, malaria, typhoid fever, pneumonia, and meningococcemia) may result in delayed diagnosis of EVD before isolation of infected patients. Radiology departments should consider policies for and approaches to decontamination of expensive and potentially easily damaged radiology equipment. In addition, the protection of radiology personnel must be considered during the work-up phase of undiagnosed EVD patients presenting to emergency departments. The purpose of this article is to consider the effect of EVD on radiology departments and imaging equipment, with particular consideration of guidelines currently available from the Centers for Disease Control and Prevention that may be applicable to radiology. (©) RSNA, 2015.

  17. Secure vendor environment (SVE) for PACS

    NASA Astrophysics Data System (ADS)

    Honeyman-Buck, Janice; Frost, Meryll

    2005-04-01

    A Secure Vendor Environment (SVE) was created to protect radiology modalities from network intrusion, worms, viruses, and other forms of damaging attacks. Many vendors do not attempt any form of network security and if an institution demands a non-standard and secure installation, a future system upgrade could and frequently does eliminate any security measures installed during the initial installation. The SVE isolates the vendor equipment behind a virtual firewall on a private network that is invisible to the outside world. All interactions must go though a device containing two network interface cards called an Application Processor that acts as a store-and forward router, performs DICOM repair, proxies modality worklist, and isolates the vendor modalities. A small VPN appliance can open the device temporarily for remote access by vendor engineers. Prior to the routine installation of the SVE, vendor equipment was often attacked by hostile network intruders and viruses or worms, sometimes rendering the equipment unusable until the vendor could reload the system. The resulted in considerable clinical downtime and loss of revenue. Since the relatively low cost SVE solution has routinely been installed with all new equipment, no intrusions have occurred, although our network sniffers and intrusion detectors indicate that we are constantly being scanned for vulnerability. Purpose: To provide a secure network for vendor equipment in a PACS environment while allowing vendor access for upgrades and system repairs. Method: The network administrators at our university believe that network security should be implemented at the machine level rather than relying on a firewall. A firewall solution could conceivably block unwanted intrusion from outside the university network, but would still allow literally thousands of potential network users to get through to the PACS network. All the PACS archive, display and routing systems are individually protected from intrusion, but vendors of image producing modalities such as CT, MRI, and CR typically do not protect their equipment from network intrusion. Most vendors use the same user-ids and passwords for their service and administrative accounts which makes it easy for them to get to their systems for remote repairs and upgrades, but also makes it easy for hackers and other unwelcome intruders to gain access. We use a device with two network interface cards to isolate the vendor network from the main PACS / university / hospital network. This device is a store and forward PACS routing device, a DICOM repair device, a modality worklist proxy device, and a de-facto firewall. This device is named an Application Processor (AP). In addition, a small virtual private network (VPN) device is placed on the system that can be controlled only by the PACS administration. If a vendor engineer needs remote access to upgrade or service the equipment, a temporary connection is enabled for only the computer the engineer is using at the time, then is closed when he/she has completed their work. Results: The secure vendor environment (SVE) consists of a computer and a VPN appliance and costs approximately 2,000 USD to build. With software, the total system costs approximately 2800 - $3500. The SVE is typically deployed as part of every equipment installation. Since the SVE has been used, we have had no intrusion and no downtime due to hackers, viruses, worms, etc. This is now a part of every project plan for equipment that will become part of the PACS. New work: The SVE is a unique and new work by our group, developed as a solution totally within our group. Conclusions: Our results have convinced our administration that this small cost to protect vendor equipment is well worth the investment. Prior to developing this solution, there were numerous occasions where intruders invaded our equipment and rendered it unusable until the software could be reloaded, sometimes resulting in the loss of a day or more of clinical use.

  18. A Platform-Independent Plugin for Navigating Online Radiology Cases.

    PubMed

    Balkman, Jason D; Awan, Omer A

    2016-06-01

    Software methods that enable navigation of radiology cases on various digital platforms differ between handheld devices and desktop computers. This has resulted in poor compatibility of online radiology teaching files across mobile smartphones, tablets, and desktop computers. A standardized, platform-independent, or "agnostic" approach for presenting online radiology content was produced in this work by leveraging modern hypertext markup language (HTML) and JavaScript web software technology. We describe the design and evaluation of this software, demonstrate its use across multiple viewing platforms, and make it publicly available as a model for future development efforts.

  19. Upgrading Custom Simulink Library Components for Use in Newer Versions of Matlab

    NASA Technical Reports Server (NTRS)

    Stewart, Camiren L.

    2014-01-01

    The Spaceport Command and Control System (SCCS) at Kennedy Space Center (KSC) is a control system for monitoring and launching manned launch vehicles. Simulations of ground support equipment (GSE) and the launch vehicle systems are required throughout the life cycle of SCCS to test software, hardware, and procedures to train the launch team. The simulations of the GSE at the launch site in conjunction with off-line processing locations are developed using Simulink, a piece of Commercial Off-The-Shelf (COTS) software. The simulations that are built are then converted into code and ran in a simulation engine called Trick, a Government off-the-shelf (GOTS) piece of software developed by NASA. In the world of hardware and software, it is not uncommon to see the products that are utilized be upgraded and patched or eventually fade away into an obsolete status. In the case of SCCS simulation software, Matlab, a MathWorks product, has released a number of stable versions of Simulink since the deployment of the software on the Development Work Stations in the Linux environment (DWLs). The upgraded versions of Simulink has introduced a number of new tools and resources that, if utilized fully and correctly, will save time and resources during the overall development of the GSE simulation and its correlating documentation. Unfortunately, simply importing the already built simulations into the new Matlab environment will not suffice as it will produce results that may not be expected as they were in the version that is currently being utilized. Thus, an upgrade execution plan was developed and executed to fully upgrade the simulation environment to one of the latest versions of Matlab.

  20. Radiology information system: a workflow-based approach.

    PubMed

    Zhang, Jinyan; Lu, Xudong; Nie, Hongchao; Huang, Zhengxing; van der Aalst, W M P

    2009-09-01

    Introducing workflow management technology in healthcare seems to be prospective in dealing with the problem that the current healthcare Information Systems cannot provide sufficient support for the process management, although several challenges still exist. The purpose of this paper is to study the method of developing workflow-based information system in radiology department as a use case. First, a workflow model of typical radiology process was established. Second, based on the model, the system could be designed and implemented as a group of loosely coupled components. Each component corresponded to one task in the process and could be assembled by the workflow management system. The legacy systems could be taken as special components, which also corresponded to the tasks and were integrated through transferring non-work- flow-aware interfaces to the standard ones. Finally, a workflow dashboard was designed and implemented to provide an integral view of radiology processes. The workflow-based Radiology Information System was deployed in the radiology department of Zhejiang Chinese Medicine Hospital in China. The results showed that it could be adjusted flexibly in response to the needs of changing process, and enhance the process management in the department. It can also provide a more workflow-aware integration method, comparing with other methods such as IHE-based ones. The workflow-based approach is a new method of developing radiology information system with more flexibility, more functionalities of process management and more workflow-aware integration. The work of this paper is an initial endeavor for introducing workflow management technology in healthcare.

  1. Canadian Association of Radiologists White Paper on Artificial Intelligence in Radiology.

    PubMed

    Tang, An; Tam, Roger; Cadrin-Chênevert, Alexandre; Guest, Will; Chong, Jaron; Barfett, Joseph; Chepelev, Leonid; Cairns, Robyn; Mitchell, J Ross; Cicero, Mark D; Poudrette, Manuel Gaudreau; Jaremko, Jacob L; Reinhold, Caroline; Gallix, Benoit; Gray, Bruce; Geis, Raym

    2018-05-01

    Artificial intelligence (AI) is rapidly moving from an experimental phase to an implementation phase in many fields, including medicine. The combination of improved availability of large datasets, increasing computing power, and advances in learning algorithms has created major performance breakthroughs in the development of AI applications. In the last 5 years, AI techniques known as deep learning have delivered rapidly improving performance in image recognition, caption generation, and speech recognition. Radiology, in particular, is a prime candidate for early adoption of these techniques. It is anticipated that the implementation of AI in radiology over the next decade will significantly improve the quality, value, and depth of radiology's contribution to patient care and population health, and will revolutionize radiologists' workflows. The Canadian Association of Radiologists (CAR) is the national voice of radiology committed to promoting the highest standards in patient-centered imaging, lifelong learning, and research. The CAR has created an AI working group with the mandate to discuss and deliberate on practice, policy, and patient care issues related to the introduction and implementation of AI in imaging. This white paper provides recommendations for the CAR derived from deliberations between members of the AI working group. This white paper on AI in radiology will inform CAR members and policymakers on key terminology, educational needs of members, research and development, partnerships, potential clinical applications, implementation, structure and governance, role of radiologists, and potential impact of AI on radiology in Canada. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  2. JOURNAL CLUB: Redefining the Radiology Curriculum in Medical School: Vertical Integration and Global Accessibility.

    PubMed

    Retrouvey, Michele; Trace, Anthony Paul; Goodmurphy, Craig W; Shaves, Sarah

    2018-01-01

    Radiology interconnects medical disciplines given that a working understanding of imaging is essential to clinicians of every specialty. Using online education, we created a globally accessible, web-based undergraduate medical radiology curriculum modeled after the National Medical Student Curriculum in Radiology program of the Alliance of Medical Student Educators in Radiology. Seventy-four radiology faculty-mentored video modules were produced, 50 of which were integrated into the 1st-year anatomy course. We administered tests to medical students before and after students saw the videos to assess the effectiveness of the modules. We surveyed students on their interests in pursuing radiology as a career before and after participating in this curriculum. On the preexamination questions, the mean score was 58.0%, which increased to 83.6% on the pair-matched imaging-related questions on the actual examination. Before participating in the new curriculum, 88% of students did not express an interest in radiology, and 9% were undecided about radiology as a future career. There was an increase in students who reported that they would definitely or most likely pursue a career in radiology (7%) after they had viewed the lectures. Radiology education is now available to a greater number of multidisciplinary learners worldwide. This project produced a comprehensive, globally accessible radiology curriculum in a self-paced, flexible learning format for new generations of physicians.

  3. A Distance Blended Learning Program to Upgrade the Clinical Competence of District Non-doctor Anesthesia Providers in Nepal.

    PubMed

    Shah, Shristi; Knoble, Stephen; Ross, Oliver; Pickering, Stephen

    2017-12-01

    Across Nepal, anesthesia at a district level is provided mostly by non-doctor anesthesia providers (anesthesia assistants-AAs). Nepal's Government recognized the need to sustain competence with continuous professional development and to upgrade 6-month trained working AAs to professional equivalence with the new national standard of 12-month training. As they are essential district health workers and AA clinical training sites are full, an innovative distance blended learning, competency-based, upgrade 1-year course was developed and conducted in 2014-2017 for two batches. The course content was developed over 18 months by a team of Nepali and overseas AA training experts. The 1-year course started with a refresher course, continued with tablet-based 12-month self-learning modules and clinical case logs, regular educational mentor communication, midcourse 2-week contact time in an AA training site, regular text messaging and ended with clinical examination and multiple-choice questions. Tablet content included 168 new case studies, pre- and posttests, video lectures, matching exercises and a resource library. All module work and logged clinical cases were uploaded centrally, where clinical mentors were able to review work. Clinical skills were upgraded, as needed, through direct clinical contact midway through the course. Quantitative and qualitative course assessments were included. Fourteen working AAs in first batch and eight working AAs in second batch from district, zonal and mission hospitals across Nepal were enrolled. All remained working at their hospitals throughout the course, and there were no significant tablet problems inhibiting course completion. Twenty-one AAs completed all modules successfully with time required for module completion averaging 19.2 h (range 11.2-32). One AA left the course after 3 months with a personal problem. Subjectively, AAs felt that the obstetric and pediatric modules were more difficult; lowest marks were objectively seen in the airway module. Clinical mentors averaged 8.2 h mentoring review work per module with direct student communication of 2.9 h per module per month. Participants logged a total of 5473 clinical cases, ranging between 50 and 788 cases each. Complications were recorded; outcomes were good. Challenges were the national IT infrastructure making data synchronization difficult and the lack of clinical exposure at some AA's hospitals. Nineteen AAs attended the final examination, and all passed. Two AAs withdrew before the final examination period due to personal and logistic reasons. This is the first use of distance blended learning to upgrade district health workers in Nepal and perhaps for non-doctor anesthesia providers globally. Key success factors were motivated students, cultural and contextualized clinical content, good educational mentoring relationships with regular communication, central IT and motivational support, and face-to-face midcourse clinical contact time.

  4. 77 FR 23238 - Guidelines for Home Energy Professionals: Standard Work Specifications for Single Family Energy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-18

    ... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy Guidelines for Home Energy... for Home Energy Professionals: Standard Work Specifications for Single Family Energy Upgrades was...: Comments on the Guidelines for Home Energy Professionals: Standard Work Specifications for Single Family...

  5. Adoption of alternative financing strategies to increase the diffusion of picture archiving and communication systems into the radiology marketplace.

    PubMed

    Reiner, B; Siegel, E; McKay, P

    2000-05-01

    The objective of the study was to evaluate current marketplace conditions and strategies employed by major picture archiving and communication systems (PACS) vendors in the creation of alternative financing strategies, to enhance the diffusion of filmless imaging. Data were collected from the major PACS vendors in the forms of survey questionnaires and review of existing leases. Topics evaluated in the survey included current financing options available, foreseeable changes in PACS financing, role of third-party financiers, and creation of risk-sharing arrangements. Generic leases were also reviewed evaluating the presence or absence of several key variables including technology obsolescence protection, hardware/software upgrades, end-of-term options, determination of fair market value, functionality/acceptance testing, uptime guarantees, and workflow management consulting. Eight of the 10 PACS vendors surveyed participated in the data collection. The vast majority of current PACS implementations (60% to 90%) occur through direct purchase, with conventional leasing (operating or capital) accounting for only 5% to 30% of PACS installations. The majority of respondents view fee-for-lease arrangements and other forms of risk sharing as increasing importance for future PACS financing. The specific targets for such risk-sharing arrangements consist of small hospital and privately owned imaging centers. Leases currently offered range in duration from 3 to 5 years and frequently offer technology obsolescence protection with upgrades, multiple end-of-term options, and some form of acceptance testing. A number of important variables frequently omitted from leases include uptime guarantees, flexibility in changing financing or vendors, and incorporation of expected productivity/operational efficiency gains. As vendors strive to increase the penetration of PACS into the radiology marketplace, there will be a shift from conventional financing (loan or purchase) to leasing. Fee-for-use leasing and other forms of risk sharing have the greatest potential in smaller hospitals, which do not have the financial resources to pursue conventional financing options. Potential PACS customers must be cautious when entering into these alternative financing strategies, to ensure that appropriate safeguards are incorporated, in order to minimize downside risk.

  6. [The future of radiology: What can we expect within the next 10 years?].

    PubMed

    Nensa, F; Forsting, M; Wetter, A

    2016-03-01

    More than other medical discipline, radiology is marked by technical innovation and continuous development, as well as the optimization of the underlying physical principles. In this respect, several trends that will crucially change and develop radiology over the next decade can be observed. Through the use of ever faster computer tomography, which also shows an ever-decreasing radiation exposure, the "workhorse" of radiology will have an even greater place and displace conventional X‑ray techniques further. In addition, hybrid imaging, which is based on a combination of nuclear medicine and radiological techniques (keywords: PET/CT, PET/MRI) will become much more established and, in particular, will improve oncological imaging further, allowing increasingly individualized imaging for specific tracers and techniques of functional magnetic resonance imaging for a particular tumour. Future radiology will be strongly characterized by innovations in the software and Internet industry, which will enable new image viewing and processing methods and open up new possibilities in the context of the organization of radiological work.

  7. Space Shuttle Projects

    NASA Image and Video Library

    2002-03-08

    After five days of service and upgrade work on the Hubble Space Telescope (HST), the STS-109 crew photographed the giant telescope in the shuttle's cargo bay. The telescope was captured and secured on a work stand in Columbia's payload bay using Columbia's robotic arm, where 4 of the 7-member crew performed 5 space walks completing system upgrades to the HST. Included in those upgrades were: The replacement of the solar array panels; replacement of the power control unit (PCU); replacement of the Faint Object Camera (FOC) with a new advanced camera for Surveys (ACS); and installation of the experimental cooling system for the Hubble's Near-Infrared Camera and Multi-object Spectrometer (NICMOS), which had been dormant since January 1999 when its original coolant ran out. The Marshall Space Flight Center had the responsibility for the design, development, and construction of the the HST, which is the most complex and sensitive optical telescope ever made, to study the cosmos from a low-Earth orbit. Launched March 1, 2002, the STS-109 HST servicing mission lasted 10 days, 22 hours, and 11 minutes. It was the 108th flight overall in NASA's Space Shuttle Program.

  8. n/a

    NASA Image and Video Library

    2002-03-09

    After five days of service and upgrade work on the Hubble Space Telescope (HST), the STS-109 crew photographed the giant telescope returning to its normal routine. The telescope was captured and secured on a work stand in Columbia's payload bay using Columbia's robotic arm, where 4 of the 7-member crew performed 5 space walks completing system upgrades to the HST. Included in those upgrades were: The replacement of the solar array panels; replacement of the power control unit (PCU); replacement of the Faint Object Camera (FOC) with a new advanced camera for Surveys (ACS); and installation of the experimental cooling system for the Hubble's Near- Infrared Camera and Multi-object Spectrometer (NICMOS), which had been dormant since January 1999 when its original coolant ran out. The Marshall Space Flight Center had the responsibility for the design, development, and construction of the the HST, which is the most complex and sensitive optical telescope ever made, to study the cosmos from a low-Earth orbit. Launched March 1, 2002, the STS-109 HST servicing mission lasted 10 days, 22 hours, and 11 minutes. It was the 108th flight overall in NASA's Space Shuttle Program.

  9. Ineffective Leadership.

    PubMed

    Itri, Jason N; Lawson, Leslie M

    2016-07-01

    Radiology leaders can have a profound impact on the success and working environment of a radiology department, promoting core values and inspiring staff members to achieve the organization's mission. On the other hand, ineffective leaders can have a devastating effect on a radiology department by impairing communication among members, undermining staff commitment to the organization's success, and stifling the development of other staff members and leaders in the organization. One of the most important investments a radiology department can make is in identifying, cultivating, and promoting new leaders. The authors describe 13 habits and characteristics of new leaders that lead these individuals to address situations in both ineffective and counterproductive ways, impeding the performance of a radiology department and its capacity to play a meaningful role in shaping the future of radiology. New leaders must continually learn and improve their leadership skills if they are to avoid the destructive habits of ineffective leaders and successfully overcome the challenges facing radiology today. Senior leaders may also benefit from understanding the pitfalls that make leaders ineffective and should strive to continually improve their leadership skills given the critical role of leadership in the success of radiology departments. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Radiation risk assessment in professionals working in dental radiology area using buccal micronucleus cytome assay.

    PubMed

    Sadatullah, Syed; Dawasaz, Ali Azhar; Luqman, Master; Assiry, Ali A; Almeshari, Ahmed A; Togoo, Rafi Ahmad

    2013-11-01

    The aim of this study was to assess the incidence of micronuclei (MN) in buccal mucosal cells of professionals working in radiology area to determine the risk of stochastic effects of radiation. All the professionals and students working in King Khalid University - College of Dentistry radiology area were included in the Risk Group (RG = 27). The Control Group (CG = 27) comprised of healthy individual matching the gender and age of the RG. Buccal mucosal scraping from all the 54 subjects of RG and CG were stained with Papanicolaou stain and observed under oil immersion lens (×100) for the presence of micronuclei (MN) in the exfoliated epithelial cells. There was no significant difference between the incidence of MN in RG and CG (p = >0.05) using t-test. Routine radiation protection protocol does minimize the risk of radiation induced cytotoxicity, however, screening of professionals should be carried out at regular intervals.

  11. Radiology corner. Answer to last month's radiology case and image: gun shot wound to the chest of a military working dog.

    PubMed

    Galer, Meghan; Magid, Donna; Folio, Les

    2009-06-01

    This Military Working Dog (MWD) was shot in the chest during combat operations in Iraq. Military Working Dogs are critical to the safety and well-being of deployed troops in combat operations and, as such, they are triaged and treated in our combat hospitals just like any other soldier; their speciation is not a factor in their triage status. This case familiarizes military physicians with the basic canine anatomy, positioning, and radiological technique they should be aware of before deploying. We also strive to raise awareness of the vital roles that these MWDs play for our forces, counterany concerns that may arise over the issue of treating these dogs in human facilities, and leave the reader feeling better prepared to handle the situation should they ever find themselves poised to save one of our four-legged warriors.

  12. Radiology Preparedness in Ebola Virus Disease: Guidelines and Challenges for Disinfection of Medical Imaging Equipment for the Protection of Staff and Patients

    PubMed Central

    Palmore, Tara N.; Folio, Les R.; Bluemke, David A.

    2015-01-01

    The overlap of early Ebola virus disease (EVD) symptoms (eg, fever, headache, abdominal pain, diarrhea, emesis, and fatigue) with symptoms of other more common travel-related diseases (eg, malaria, typhoid fever, pneumonia, and meningococcemia) may result in delayed diagnosis of EVD before isolation of infected patients. Radiology departments should consider policies for and approaches to decontamination of expensive and potentially easily damaged radiology equipment. In addition, the protection of radiology personnel must be considered during the work-up phase of undiagnosed EVD patients presenting to emergency departments. The purpose of this article is to consider the effect of EVD on radiology departments and imaging equipment, with particular consideration of guidelines currently available from the Centers for Disease Control and Prevention that may be applicable to radiology. © RSNA, 2015 PMID:25654616

  13. Acquainting Future Office Employees with Productivity-Improvement Techniques.

    ERIC Educational Resources Information Center

    Quible, Zane K.

    1982-01-01

    Examines factors affecting productivity (government regulations, energy costs, decline in the work ethic, capital investment, number of service workers, work force characteristics, management practices, and unions), and techniques to improve productivity (employee involvement, job structure, communication, flexitime, employee upgrading, incentive…

  14. NETL- Severe Environment Corrosion Erosion Facility

    ScienceCinema

    None

    2018-01-16

    NETL's Severe Environment Corrosion Erosion Facility in Albany studies how new and old materials will stand up to new operating conditions. Work done in the lab supports NETL's oxy-fuel combustion oxidation work, refractory materials stability work, and the fuels program, in particular the hydrogen membrane materials stability work, to determine how best to upgrade existing power plants.

  15. Alternative Work Patterns. Facts on U.S. Working Women. Fact Sheet No. 86-3.

    ERIC Educational Resources Information Center

    Women's Bureau (DOL), Washington, DC.

    Alternative work schedules can help parents of young children. They are also attractive to students, older workers, handicapped persons, couples desiring to share work and home responsibilities, persons wishing to upgrade skills or switch careers through a return to school, and employers needing to serve the public outside the traditional workday,…

  16. Cryogenic testing of Planck sorption cooler test facility

    NASA Technical Reports Server (NTRS)

    Zhang, B.; Pearson, D.; Borders, J.; Franklin, B.; Prina, M.; Hardy, J.; Crumb, D.

    2004-01-01

    A test facility has been upgraded in preparation for testing of two hydrogen sorption cryocoolers operating at 18/20 K. these sorption coolers are currently under development at the Jet Propulsion Laboratory. This work summarizes the scope of the test facility upgrade, including design for cryogenic cooling power delivery, system thermal management, insulation schemes, and data acquisition techniques. Ground support equipment for the sorption coolers, structural features of the test chamber, and the vacuum system involved for system testing will also be described in detail.

  17. Medical examinations for radiation workers

    NASA Technical Reports Server (NTRS)

    Alexander, R. E.

    1969-01-01

    The NASA radiological protection policy allows an employee to be assigned work in a radiologically controlled area only if all of the following conditions are met: (1) The area must be radiologically safe for the intended operations; (2) the employee must be medically fit; (3) the employee must be properly trained; (4) appropriate radiation protection procedures must be prepared; (5) appropriate dosimetric, survey, surveillance and reporting procedures must be implemented; and (6) adequate controls and records must be established.

  18. Radiological protection in computed tomography and cone beam computed tomography.

    PubMed

    Rehani, M M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  19. Assessment of the occupational eye lens dose for clinical staff in interventional radiology, cardiology and neuroradiology.

    PubMed

    Omar, Artur; Kadesjö, Nils; Palmgren, Charlotta; Marteinsdottir, Maria; Segerdahl, Tony; Fransson, Annette

    2017-03-20

    In accordance with recommendations by the International Commission on Radiological Protection, the current European Basic Safety Standards has adopted a reduced occupational eye lens dose limit of 20 mSv yr -1 . The radiation safety implications of this dose limit is of concern for clinical staff that work with relatively high dose x-ray angiography and interventional radiology. Presented in this work is a thorough assessment of the occupational eye lens dose based on clinical measurements with active personal dosimeters worn by staff during various types of procedures in interventional radiology, cardiology and neuroradiology. Results are presented in terms of the estimated equivalent eye lens dose for various medical professions. In order to compare the risk of exceeding the regulatory annual eye lens dose limit for the widely different clinical situations investigated in this work, the different medical professions were separated into categories based on their distinct work pattern: staff that work (a) regularly beside the patient, (b) in proximity to the patient and (c) typically at a distance from the patient. The results demonstrate that the risk of exceeding the annual eye lens dose limit is of concern for staff category (a), i.e. mainly the primary radiologist/cardiologist. However, the results also demonstrate that the risk can be greatly mitigated if radiation protection shields are used in the clinical routine. The results presented in this work cover a wide range of clinical situations, and can be used as a first indication of the risk of exceeding the annual eye lens dose limit for staff at other medical centres.

  20. NNSA B-Roll: Second Line of Defense

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2010-05-21

    The NNSA Office of Second Line of Defense (SLD) works to prevent illicit trafficking in nuclear and radiological materials by securing international land borders, seaports and airports that may be used as smuggling routes for materials needed for a nuclear device or a radiological dispersal device.

  1. Doctor-patient communication in radiology: a great opportunity for future radiology.

    PubMed

    Bazzocchi, M

    2012-04-01

    This text discusses several aspects of doctor-patient communication in radiology, including the origins, advantages, and ethical and legal aspects. Over the last 10 years, radiologists have assumed increasing responsibilities towards patients and society. Patients, who are becoming better informed and more aware about medical issues, have a right to be given a timely diagnosis and want to receive as much information as possible from the radiologist. This has implications for several levels of everyday radiological practice, including the organisation of work, legal and ethical aspects and radiologist training. Better interaction with the patient helps to build a closer, more trusting, relationship with the result that the radiologist will be more motivated in his or her work. Until now, radiologists were not adequately trained to communicate the diagnosis directly and verbally to patients, especially when the diagnosis was unfavourable. It is important to emphasise the need for more specific and practical training in this respect, which is indispensable for future developments of the discipline.

  2. Hand-held digital books in radiology: convenient access to information.

    PubMed

    D'Alessandro, M P; Galvin, J R; Santer, D M; Erkonen, W E

    1995-02-01

    Radiologists need constant, convenient access to current information throughout the course of their daily work. Today most learning in radiology is obtained from the printed word in books, journals, and teaching files, supplemented by the spoken word in lectures and conferences. Although learning from printed material and lectures has been proved efficacious over time, these media share the disadvantage of not being conveniently available for reference during the course of daily work at the alternator or in the examination room when accurate and up-to-date information is needed the most. As a result, many important questions about patient care go unanswered. We have developed a technique--hand-held digital books--to lower this barrier to searching and retrieval. When radiologists have a digital library that can be carried with them, they will be able to incorporate current radiology information into their daily decision making. We describe a technique for creating hand-held digital books and their future use in radiology.

  3. [Quality of life and job performance resulting from operatively treated tibial plateau fractures].

    PubMed

    Roßbach, B P; Faymonville, C; Müller, L P; Stützer, H; Isenberg, J

    2016-01-01

    The aim of this article is to present the functional results and the effect on quality of life of surgically treated tibial plateau fractures in physically active and working patients with multiple and serious injuries. In addition, the relationships between functional and radiological outcome were evaluated and compared with activity in daily and professional life. In all, 41 injured patients were followed up a mean of 47 months after surgical treatment and examined with radiological, functional, as well as quality of life score. In the radiological scoring, a mean value of 72 points (max 100 points) was achieved. In the activity score, there was an average of 63.5 points (max 100 points). When evaluating the health-related quality of life, an average score of 69.6 points was achieved. There was a significant relationship between radiological and activity scores and the radiological and life quality scores. Furthermore, the relationship between activity and quality of life scores was considered significant. Surgeon's influence on the functional outcome could be confirmed. The functional and the radiological results were moderate. Quality of life was permanently affected by the consequences of tibial plateau fracture in 12 patients; 11 patients were not re-employed. However, the quality of life was assessed as good or very good and 28 patients had returned to work. The quality of life was firmly linked to the radiological and functional parameters, which tended to be influenced by the quality of the primary surgical treatment when looking at the overall population.

  4. 3D simulation as a tool for improving the safety culture during remediation work at Andreeva Bay.

    PubMed

    Chizhov, K; Sneve, M K; Szőke, I; Mazur, I; Mark, N K; Kudrin, I; Shandala, N; Simakov, A; Smith, G M; Krasnoschekov, A; Kosnikov, A; Kemsky, I; Kryuchkov, V

    2014-12-01

    Andreeva Bay in northwest Russia hosts one of the former coastal technical bases of the Northern Fleet. Currently, this base is designated as the Andreeva Bay branch of Northwest Center for Radioactive Waste Management (SevRAO) and is a site of temporary storage (STS) for spent nuclear fuel (SNF) and other radiological waste generated during the operation and decommissioning of nuclear submarines and ships. According to an integrated expert evaluation, this site is the most dangerous nuclear facility in northwest Russia. Environmental rehabilitation of the site is currently in progress and is supported by strong international collaboration. This paper describes how the optimization principle (ALARA) has been adopted during the planning of remediation work at the Andreeva Bay STS and how Russian-Norwegian collaboration greatly contributed to ensuring the development and maintenance of a high level safety culture during this process. More specifically, this paper describes how integration of a system, specifically designed for improving the radiological safety of workers during the remediation work at Andreeva Bay, was developed in Russia. It also outlines the 3D radiological simulation and virtual reality based systems developed in Norway that have greatly facilitated effective implementation of the ALARA principle, through supporting radiological characterisation, work planning and optimization, decision making, communication between teams and with the authorities and training of field operators.

  5. Comparison of acoustic fields produced by the original and upgraded HM-3 lithotripter

    NASA Astrophysics Data System (ADS)

    Zhou, Yufeng; Zhu, Songlin; Dreyer, Thomas; Liebler, Marko; Zhong, Pei

    2003-10-01

    To reduce tissue injury in shock wave lithotripsy (SWL) while maintaining satisfactory stone comminution, an original HM-3 lithotripter was upgraded by a reflector insert to suppress large intraluminal bubble expansion, which is a primary mechanism of vascular injury in SWL. The pressure waveforms produced by the original and upgraded HM-3 lithotripter were measured by using a fiber optical probe hydrophone (FOPH), which was scanned both along and transverse to the lithotripter axis at 1-mm step using a computer-controlled 3-D positioning system. At F2, the pressure waveform produced by the upgraded HM-3 lithotripter at 22 kV has a distinct dual-pulse structure, with a leading shock wave of ~45 MPa from the reflector insert and a 4-μs delayed second pulse of ~15 MPa reflected from the uncovered bottom surface of the original HM-3 reflector. The beam sizes of the original and upgraded HM-3 lithotripter are comparable in both axial and lateral directions. The pressure waveforms measured at the reflector aperture will be used as input to the KZK equation to predict the lithotripter shock wave at F2. Furthermore, bubble dynamics predicted by the Gilmore model will be compared with experimental observation by high-speed imaging. [Work supported by NIH.

  6. Radiological Safety Handbook.

    ERIC Educational Resources Information Center

    Army Ordnance Center and School, Aberdeen Proving Ground, MD.

    Written to be used concurrently with the U.S. Army's Radiological Safety Course, this publication discusses the causes, sources, and detection of nuclear radiation. In addition, the transportation and disposal of radioactive materials are covered. The report also deals with the safety precautions to be observed when working with lasers, microwave…

  7. New trends in radiology workstation design

    NASA Astrophysics Data System (ADS)

    Moise, Adrian; Atkins, M. Stella

    2002-05-01

    In the radiology workstation design, the race for adding more features is now morphing into an iterative user centric design with the focus on ergonomics and usability. The extent of the list of features for the radiology workstation used to be one of the most significant factors for a Picture Archiving and Communication System (PACS) vendor's ability to sell the radiology workstation. Not anymore is now very much the same between the major players in the PACS market. How these features work together distinguishes different radiology workstations. Integration (with the PACS/Radiology Information System (RIS) systems, with the 3D tool, Reporting Tool etc.), usability (user specific preferences, advanced display protocols, smart activation of tools etc.) and efficiency (what is the output a radiologist can generate with the workstation) are now core factors for selecting a workstation. This paper discusses these new trends in radiology workstation design. We demonstrate the importance of the interaction between the PACS vendor (software engineers) and the customer (radiologists) during the radiology workstation design. We focus on iterative aspects of the workstation development, such as the presentation of early prototypes to as many representative users as possible during the software development cycle and present the results of a survey of 8 radiologists on designing a radiology workstation.

  8. Towards case-based medical learning in radiological decision making using content-based image retrieval

    PubMed Central

    2011-01-01

    Background Radiologists' training is based on intensive practice and can be improved with the use of diagnostic training systems. However, existing systems typically require laboriously prepared training cases and lack integration into the clinical environment with a proper learning scenario. Consequently, diagnostic training systems advancing decision-making skills are not well established in radiological education. Methods We investigated didactic concepts and appraised methods appropriate to the radiology domain, as follows: (i) Adult learning theories stress the importance of work-related practice gained in a team of problem-solvers; (ii) Case-based reasoning (CBR) parallels the human problem-solving process; (iii) Content-based image retrieval (CBIR) can be useful for computer-aided diagnosis (CAD). To overcome the known drawbacks of existing learning systems, we developed the concept of image-based case retrieval for radiological education (IBCR-RE). The IBCR-RE diagnostic training is embedded into a didactic framework based on the Seven Jump approach, which is well established in problem-based learning (PBL). In order to provide a learning environment that is as similar as possible to radiological practice, we have analysed the radiological workflow and environment. Results We mapped the IBCR-RE diagnostic training approach into the Image Retrieval in Medical Applications (IRMA) framework, resulting in the proposed concept of the IRMAdiag training application. IRMAdiag makes use of the modular structure of IRMA and comprises (i) the IRMA core, i.e., the IRMA CBIR engine; and (ii) the IRMAcon viewer. We propose embedding IRMAdiag into hospital information technology (IT) infrastructure using the standard protocols Digital Imaging and Communications in Medicine (DICOM) and Health Level Seven (HL7). Furthermore, we present a case description and a scheme of planned evaluations to comprehensively assess the system. Conclusions The IBCR-RE paradigm incorporates a novel combination of essential aspects of diagnostic learning in radiology: (i) Provision of work-relevant experiences in a training environment integrated into the radiologist's working context; (ii) Up-to-date training cases that do not require cumbersome preparation because they are provided by routinely generated electronic medical records; (iii) Support of the way adults learn while remaining suitable for the patient- and problem-oriented nature of medicine. Future work will address unanswered questions to complete the implementation of the IRMAdiag trainer. PMID:22032775

  9. Towards case-based medical learning in radiological decision making using content-based image retrieval.

    PubMed

    Welter, Petra; Deserno, Thomas M; Fischer, Benedikt; Günther, Rolf W; Spreckelsen, Cord

    2011-10-27

    Radiologists' training is based on intensive practice and can be improved with the use of diagnostic training systems. However, existing systems typically require laboriously prepared training cases and lack integration into the clinical environment with a proper learning scenario. Consequently, diagnostic training systems advancing decision-making skills are not well established in radiological education. We investigated didactic concepts and appraised methods appropriate to the radiology domain, as follows: (i) Adult learning theories stress the importance of work-related practice gained in a team of problem-solvers; (ii) Case-based reasoning (CBR) parallels the human problem-solving process; (iii) Content-based image retrieval (CBIR) can be useful for computer-aided diagnosis (CAD). To overcome the known drawbacks of existing learning systems, we developed the concept of image-based case retrieval for radiological education (IBCR-RE). The IBCR-RE diagnostic training is embedded into a didactic framework based on the Seven Jump approach, which is well established in problem-based learning (PBL). In order to provide a learning environment that is as similar as possible to radiological practice, we have analysed the radiological workflow and environment. We mapped the IBCR-RE diagnostic training approach into the Image Retrieval in Medical Applications (IRMA) framework, resulting in the proposed concept of the IRMAdiag training application. IRMAdiag makes use of the modular structure of IRMA and comprises (i) the IRMA core, i.e., the IRMA CBIR engine; and (ii) the IRMAcon viewer. We propose embedding IRMAdiag into hospital information technology (IT) infrastructure using the standard protocols Digital Imaging and Communications in Medicine (DICOM) and Health Level Seven (HL7). Furthermore, we present a case description and a scheme of planned evaluations to comprehensively assess the system. The IBCR-RE paradigm incorporates a novel combination of essential aspects of diagnostic learning in radiology: (i) Provision of work-relevant experiences in a training environment integrated into the radiologist's working context; (ii) Up-to-date training cases that do not require cumbersome preparation because they are provided by routinely generated electronic medical records; (iii) Support of the way adults learn while remaining suitable for the patient- and problem-oriented nature of medicine. Future work will address unanswered questions to complete the implementation of the IRMAdiag trainer.

  10. Prototypes and system test stands for the Phase 1 upgrade of the CMS pixel detector

    DOE PAGES

    Hasegawa, S.

    2016-04-23

    The CMS pixel phase-1 upgrade project replaces the current pixel detector with an upgraded system with faster readout electronics during the extended year-end technical stop of 2016/2017. New electronics prototypes for the system have been developed, and tests in a realistic environment for a comprehensive evaluation are needed. A full readout test stand with either the same hardware as used in the current CMS pixel detector or the latest prototypes of upgrade electronics has been built. The setup enables the observation and investigation of a jitter increase in the data line associated with trigger rate increases. This effect is duemore » to the way in which the clock and trigger distribution is implemented in CMS. A new prototype of the electronics with a PLL based on a voltage controlled quartz crystal oscillator (QPLL), which works as jitter filter, in the clock distribution path was produced. With the test stand, it was confirmed that the jitter increase is not seen with the prototype, and also good performance was confirmed at the expected detector operation temperature ($-$20 °C).« less

  11. The performance of the upgraded Los Alamos Neutron Source

    NASA Astrophysics Data System (ADS)

    Ito, Takeyasu; LANL UCN Source Collaboration

    2017-09-01

    Los Alamos National Laboratory has been operating an ultracold (UCN) source based on a solid deuterium (SD2) UCN converter driven by spallation neutrons for over 10 years. It has recently been successfully upgraded, by replacing the cryostat that contains the cold neutron moderator, SD2 volume, and vertical UCN guide. The horizontal UCN guide that transports UCN out of the radiation shield was also replaced. The new design reflects lessons learned from the 10+ year long operation of the previous version of the UCN source and is optimized to maximize the cold neutron flux at the SD2 volume, featuring a close coupled cold neutron moderator, and maximize the transport of the UCN to experiments. During the commissioning of the upgraded UCN source, data were collected to measure its performance, including cold neutron spectra as a function of the cold moderator temperature, and the UCN density in a vessel outside the source. In this talk, after a brief overview of the design of the upgraded source, the results of the performance tests and comparison to prediction will be presented. This work was funded by LANL LDRD.

  12. Conceptual Design of the Cryogenic System for the High-luminosity Upgrade of the Large Hadron Collider (LHC)

    NASA Astrophysics Data System (ADS)

    Brodzinski, K.; Claudet, S.; Ferlin, G.; Tavian, L.; Wagner, U.; Van Weelderen, R.

    The discovery of a Higgs boson at CERN in 2012 is the start of a major program of work to measure this particle's properties with the highest possible precision for testing the validity of the Standard Model and to search for further new physics at the energy frontier. The LHC is in a unique position to pursue this program. Europe's top priority is the exploitation of the full potential of the LHC, including the high-luminosity upgrade of the machine and detectors with an objective to collect ten times more data than in the initial design, by around 2030. To reach this objective, the LHC cryogenic system must be upgraded to withstand higher beam current and higher luminosity at top energy while keeping the same operation availability by improving the collimation system and the protection of electronics sensitive to radiation. This paper will present the conceptual design of the cryogenic system upgrade with recent updates in performance requirements, the corresponding layout and architecture of the system as well as the main technical challenges which have to be met in the coming years.

  13. 76 FR 58520 - Proposed Collection; Comment Request; Cancer Risk in U.S. Radiologic Technologists: Fourth Survey...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-21

    ... medical outcomes, personal medical radiation procedures, and other risk factors from all participants... worked with radioisotopes and interventional radiography procedures, and new or updated risk factors that... Request; Cancer Risk in U.S. Radiologic Technologists: Fourth Survey (NCI) SUMMARY: In compliance with the...

  14. [Radiologic risk and INAIL insurance].

    PubMed

    Matarasso, S; Coraggio, F; Martuscelli, R; D'Antonio, F

    1990-09-01

    The Authors examine in this scientific work the radiological risk to which the dentist is exposed during his daily professional activity. They underline, moreover, the partial interpretation of the regulation in force by INAIL and ANPEQ that bind the dentist to a series of accomplishments that seem unjustified as regards the laws in force.

  15. Work history and mortality risks in 90,268 US radiological technologists.

    PubMed

    Liu, Jason J; Freedman, D Michal; Little, Mark P; Doody, Michele M; Alexander, Bruce H; Kitahara, Cari M; Lee, Terrence; Rajaraman, Preetha; Miller, Jeremy S; Kampa, Diane M; Simon, Steven L; Preston, Dale L; Linet, Martha S

    2014-12-01

    There have been few studies of work history and mortality risks in medical radiation workers. We expanded by 11 years and more outcomes our previous study of mortality risks and work history, a proxy for radiation exposure. Using Cox proportional hazards models, we estimated mortality risks according to questionnaire work history responses from 1983 to 1989 through 2008 by 90,268 US radiological technologists. We controlled for potential confounding by age, birth year, smoking history, body mass index, race and gender. There were 9566 deaths (3329 cancer and 3020 circulatory system diseases). Mortality risks increased significantly with earlier year began working for female breast (p trend=0.01) and stomach cancers (p trend=0.01), ischaemic heart (p trend=0.03) and cerebrovascular diseases (p trend=0.02). The significant trend with earlier year first worked was strongly apparent for breast cancer during baseline through 1997, but not 1998-2008. Risks were similar in the two periods for circulatory diseases. Radiological technologists working ≥5 years before 1950 had elevated mortality from breast cancer (HR=2.05, 95% CI 1.27 to 3.32), leukaemia (HR=2.57, 95% CI 0.96 to 6.68), ischaemic heart disease (HR=1.13, 95% CI 0.96 to 1.33) and cerebrovascular disease (HR=1.28, 95% CI 0.97 to 1.69). No other work history factors were consistently associated with mortality risks from specific cancers or circulatory diseases, or other conditions. Radiological technologists who began working in early periods and for more years before 1950 had increased mortality from a few cancers and some circulatory system diseases, likely reflecting higher occupational radiation exposures in the earlier years. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Measuring and improving productivity in general radiology.

    PubMed

    Wilt, Michelle A; Miranda, Rafael; Johnson, C Daniel; Love, Peggy Sue

    2010-10-01

    The aim of this study was to determine a method of measuring productivity among general radiographers in a moderate-sized hospital and to improve and sustain productivity within that work area. The average times needed to perform the 13 most common examinations were measured. Performance of the various examinations was tracked and multiplied by the time allocated per procedure; this measure was divided by the length of the work shift to determine productivity. Productivity measures were shared among the work group, and decisions to improve productivity (eg, whether to fill open positions) were made by group members. Average time spent per examination type was calculated (range, 10 minutes to 1 hour 16 minutes). At baseline (February 2008), group productivity was 50%. Productivity increased during the first year of monitoring and was sustained through November 2009 (productivity range, 57%-63%). Yearly savings from not filling open positions were estimated to be $174,000. Productivity in a general radiology work area can be measured. Consensus among the work group helped increase productivity and assess progress. This methodology, if widely adopted, could be standardized and used to compare productivity across departments and institutions. Copyright © 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Radiological emergency: Malaysian preparedness and response.

    PubMed

    Yusof, Mohd Abd Wahab; Ali, Hamrah Mohd

    2011-07-01

    Planning and preparation in advance for radiological emergencies can help to minimise potential public health and environmental threats if and when an actual emergency occurs. During the planning process, emergency response organisations think through how they would respond to each type of incident and the resources that will be needed. In Malaysia, planning, preparation for and response to radiological emergencies involve many parties. In the event of a radiological emergency and if it is considered a disaster, the National Security Council, the Atomic Energy Licensing Board and the Malaysian Nuclear Agency (Nuclear Malaysia) will work together with other federal agencies, state and local governments, first responders and international organisations to monitor the situation, contain the release, and clean up the contaminated site. Throughout the response, these agencies use their protective action guidelines. This paper discusses Malaysian preparedness for, and response to, any potential radiological emergency.

  18. Ergonomics in radiology.

    PubMed

    Goyal, N; Jain, N; Rachapalli, V

    2009-02-01

    The use of computers is increasing in every field of medicine, especially radiology. Filmless radiology departments, speech recognition software, electronic request forms and teleradiology are some of the recent developments that have substantially increased the amount of time a radiologist spends in front of a computer monitor. Computers are also needed for searching literature on the internet, communicating via e-mails, and preparing for lectures and presentations. It is well known that regular computer users can suffer musculoskeletal injuries due to repetitive stress. The role of ergonomics in radiology is to ensure that working conditions are optimized in order to avoid injury and fatigue. Adequate workplace ergonomics can go a long way in increasing productivity, efficiency, and job satisfaction. We review the current literature pertaining to the role of ergonomics in modern-day radiology especially with the development of picture archiving and communication systems (PACS) workstations.

  19. Upgrade of the neutral particle analyzers for the TJ-II stellarator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fontdecaba, J. M., E-mail: josepmaria.fontdecaba@ciemat.es; Ros, A.; McCarthy, K. J.

    2014-11-15

    The TJ-II stellarator, a magnetically confined plasma device, is equipped with a broad range of diagnostics for plasma characterization. These include 4 neutral particle analyzers (NPAs), consisting of two Acord-12's, to perform poloidal measurements, plus a compact NPA, and an Acord-24, these in tangential viewing positions. The Acord-12's were originally equipped with two rows of 6 channels each, one for hydrogen neutrals and the other for deuterium neutrals but were changed to a single row of 12 detectors for hydrogen, the principal working gas in TJ-II. With this upgrade the resultant improved energy resolution spectrum has allowed more reliable ionmore » temperature estimates to be obtained. Here we present the upgrades undertaken and present results to demonstrate the improved performance of this diagnostic.« less

  20. Emergency Radiology Practice Patterns: Shifts, Schedules, and Job Satisfaction.

    PubMed

    Hanna, Tarek N; Shekhani, Haris; Lamoureux, Christine; Mar, Hanna; Nicola, Refky; Sliker, Clint; Johnson, Jamlik-Omari

    2017-03-01

    To assess the practice environment of emergency radiologists with a focus on schedule, job satisfaction, and self-perception of health, wellness, and diagnostic accuracy. A survey drawing from prior radiology and health care shift-work literature was distributed via e-mail to national societies, teleradiology groups, and private practices. The survey remained open for 4 weeks in 2016, with one reminder. Data were analyzed using hypothesis testing and logistic regression modeling. Response rate was 29.6% (327/1106); 69.1% of respondents (n = 226) were greater than 40 years old, 73% (n = 240) were male, and 87% (n = 284) practiced full time. With regard to annual overnight shifts (NS): 36% (n = 118) did none, 24.9% (n = 81) did 182 or more, and 15.6% (n = 51) did 119. There was a significant association between average NS worked per year and both perceived negative health effects (P < .01) and negative impact on memory (P < .01). There was an inverse association between overall job enjoyment and number of annual NS (P < .05). The odds of agreeing to the statement "I enjoy my job" for radiologists who work no NS is 2.21 times greater than for radiologists who work at least 119 NS, when shift length is held constant. Radiologists with 11+ years of experience who work no NS or 1 to 100 NS annually have lower odds of feeling overwhelmed when compared with those working the same number of NS with <10 years' experience. There is significant variation in emergency radiology practice patterns. Annual NS burden is associated with lower job satisfaction and negative health self-perception. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. The Interventional Radiology (IR) Gender Gap: A Prospective Online Survey by the Cardiovascular and Interventional Radiological Society of Europe (CIRSE).

    PubMed

    Wah, Tze Min; Belli, Anna Maria

    2018-05-22

    A prospective online survey was conducted by the Cardiovascular Interventional Radiological Society of Europe (CIRSE) to evaluate the gender gap within interventional radiology (IR) and the barriers facing women in IR. A questionnaire ("Appendix") was devised by the authors and the CIRSE communication and publication team and sent electronically to 750 identifiable female members of CIRSE. Responses were collected from 7 August to 24 August 2017. The response rate was 19.9% (n = 149) with highest responses from UK (18%), Italy (11%), Germany (11%), Spain (7%), Netherlands (5%), France (5%), Sweden (4%), USA (4%). 91% of the respondents were between 31 and 46 years, 83% work full time, 62% spend > 50% of their working time in IR, and 67% practice in a university or tertiary referral institution. 85% were in the minority in their department. 52% had no leadership role in their department, but 67% expressed willingness to consider a leadership position. Their main concerns were work/family life balance, the risks of radiation exposure, the effect of pregnancy on training and practice and the male-dominated work environment. This survey highlights issues experienced by women in IR. Clear guidance on concerns regarding radiation exposure particularly during pregnancy is needed. Structured and supportive training is required for female IRs who may wish to train or work flexibly. The male-dominated environment is discouraging, and a scheme to promote female IRs would encourage women to take on senior leadership positions and attract more women into the specialty.

  2. Best Practices for the Security of Radioactive Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coulter, D.T.; Musolino, S.

    2009-05-01

    This work is funded under a grant provided by the US Department of Health and Human Services, Centers for Disease Control. The Department of Health and Mental Hygiene (DOHMH) awarded a contract to Brookhaven National Laboratory (BNL) to develop best practices guidance for Office of Radiological Health (ORH) licensees to increase on-site security to deter and prevent theft of radioactive materials (RAM). The purpose of this document is to describe best practices available to manage the security of radioactive materials in medical centers, hospitals, and research facilities. There are thousands of such facilities in the United States, and recent studiesmore » suggest that these materials may be vulnerable to theft or sabotage. Their malevolent use in a radiological-dispersion device (RDD), viz., a dirty bomb, can have severe environmental- and economic- impacts, the associated area denial, and potentially large cleanup costs, as well as other effects on the licensees and the public. These issues are important to all Nuclear Regulatory Commission and Agreement State licensees, and to the general public. This document outlines approaches for the licensees possessing these materials to undertake security audits to identify vulnerabilities in how these materials are stored or used, and to describe best practices to upgrade or enhance their security. Best practices can be described as the most efficient (least amount of effort/cost) and effective (best results) way of accomplishing a task and meeting an objective, based on repeatable procedures that have proven themselves over time for many people and circumstances. Best practices within the security industry include information security, personnel security, administrative security, and physical security. Each discipline within the security industry has its own 'best practices' that have evolved over time into common ones. With respect to radiological devices and radioactive-materials security, industry best practices encompass both physical security (hardware and engineering) and administrative procedures. Security regimes for these devices and materials typically use a defense-in-depth- or layered-security approach to eliminate single points of failure. The Department of Energy, the Department of Homeland Security, the Department of Defense, the American Society of Industrial Security (ASIS), the Security Industry Association (SIA) and Underwriters Laboratory (UL) all rovide design guidance and hardware specifications. With a graded approach, a physical-security specialist can tailor an integrated security-management system in the most appropriate cost-effective manner to meet the regulatory and non-regulatory requirements of the licensee or client.« less

  3. Accelerating the Delivery of Home Performance Upgrades through a Synergistic Business Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schirber, Tom; Ojczyk, Cindy

    Achieving Building America energy savings goals (40% by 2030) will require many existing homes to install energy upgrades. Engaging large numbers of homeowners in building science-guided upgrades during a single remodeling event has been difficult for a number of reasons. Performance upgrades in existing homes tend to occur over multiple years and usually result from component failures (furnace failure) and weather damage (ice dams, roofing, siding). This research attempted to: A) understand the homeowner's motivations regarding investing in building science based performance upgrades; B) determining a rapidly scalable approach to engage large numbers of homeowners directly through existing customer networks;more » and C) access a business model that will manage all aspects of the contractor-homeowner-performance professional interface to ensure good upgrade decisions over time. The solution results from a synergistic approach utilizing networks of suppliers merging with networks of homeowner customers. Companies in the $400 to $800 billion home services industry have proven direct marketing and sales proficiencies that have led to the development of vast customer networks. Companies such as pest control, lawn care, and security have nurtured these networks by successfully addressing the ongoing needs of homes. This long-term access to customers and trust established with consistent delivery has also provided opportunities for home service providers to grow by successfully introducing new products and services like attic insulation and air sealing. The most important component for success is a business model that will facilitate and manage the process. The team analyzes a group that developed a working model.« less

  4. Building America Case Study: Accelerating the Delivery of Home-Performance Upgrades Using a Synergistic Business Model, Minneapolis, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Achieving Building America energy savings goals (40 percent by 2030) will require many existing homes to install energy upgrades. Engaging large numbers of homeowners in building science-guided upgrades during a single remodeling event has been difficult for a number of reasons. Performance upgrades in existing homes tend to occur over multiple years and usually result from component failures (furnace failure) and weather damage (ice dams, roofing, siding). This research attempted to: A) Understand the homeowner's motivations regarding investing in building science based performance upgrades. B) Determining a rapidly scalable approach to engage large numbers of homeowners directly through existing customermore » networks. C) Access a business model that will manage all aspects of the contractor-homeowner-performance professional interface to ensure good upgrade decisions over time. The solution results from a synergistic approach utilizing networks of suppliers merging with networks of homeowner customers. Companies in the $400 to $800 billion home services industry have proven direct marketing and sales proficiencies that have led to the development of vast customer networks. Companies such as pest control, lawn care, and security have nurtured these networks by successfully addressing the ongoing needs of homes. This long-term access to customers and trust established with consistent delivery has also provided opportunities for home service providers to grow by successfully introducing new products and services like attic insulation and air sealing. The most important component for success is a business model that will facilitate and manage the process. The team analyzes a group that developed a working model.« less

  5. Improving Radiation Awareness and Feeling of Personal Security of Non-Radiological Medical Staff by Implementing a Traffic Light System in Computed Tomography.

    PubMed

    Heilmaier, C; Mayor, A; Zuber, N; Fodor, P; Weishaupt, D

    2016-03-01

    Non-radiological medical professionals often need to remain in the scanning room during computed tomography (CT) examinations to supervise patients in critical condition. Independent of protective devices, their position significantly influences the radiation dose they receive. The purpose of this study was to assess if a traffic light system indicating areas of different radiation exposure improves non-radiological medical staff's radiation awareness and feeling of personal security. Phantom measurements were performed to define areas of different dose rates and colored stickers were applied on the floor according to a traffic light system: green = lowest, orange = intermediate, and red = highest possible radiation exposure. Non-radiological medical professionals with different years of working experience evaluated the system using a structured questionnaire. Kruskal-Wallis and Spearman's correlation test were applied for statistical analysis. Fifty-six subjects (30 physicians, 26 nursing staff) took part in this prospective study. Overall rating of the system was very good, and almost all professionals tried to stand in the green stickers during the scan. The system significantly increased radiation awareness and feeling of personal protection particularly in staff with ≤ 5 years of working experience (p < 0.05). The majority of non-radiological medical professionals stated that staying in the green stickers and patient care would be compatible. Knowledge of radiation protection was poor in all groups, especially among entry-level employees (p < 0.05). A traffic light system in the CT scanning room indicating areas with lowest, intermediate, and highest possible radiation exposure is much appreciated. It increases radiation awareness, improves the sense of personal radiation protection, and may support endeavors to lower occupational radiation exposure, although the best radiation protection always is to re-main outside the CT room during the scan. • A traffic light system indicating areas with different radiation exposure within the computed tomography scanner room is much appreciated by non-radiological medical staff. • The traffic light system increases non-radiological medical staff's radiation awareness and feeling of personal protection. • Knowledge on radiation protection was poor in non-radiological medical staff, especially in those with few working experience. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Radiology Physician Extenders: A Literature Review of the History and Current Roles of Physician Extenders in Medical Imaging.

    PubMed

    Sanders, Vicki L; Flanagan, Jennifer

    2015-01-01

    The purpose of the literature review was to assess the origins of radiology physician extenders and examine the current roles found in the literature of advanced practice physician extenders within medical imaging. Twenty-six articles relating to physician assistants (PAs), nurse practitioners (NPs), radiologist assistants (RAs), and nuclear medicine advanced associates (NMAAs) were reviewed to discern similarities and differences in history, scope of practice, and roles in the medical imaging field. The literature showed PAs and NPs are working mostly in interventional radiology. PAs, NPs, and RAs perform similar tasks in radiology, including history and physicals, evaluation and management, preprocedure work-up, obtaining informed consent, initial observations/reports, and post-procedure follow-up. NPs and PAs perform a variety of procedures but most commonly vascular access, paracentesis, and thoracentesis. RAs perform gastrointestinal, genitourinary, nonvascular invasive fluoroscopy procedures, and vascular access procedures. The review revealed NMAAs are working in an advanced role, but no specific performances of procedures was found in the literature, only suggested tasks and clinical competencies. PAs, NPs, and RAs are currently the three main midlevel providers used in medical imaging. These midlevel providers are being used in a variety of ways to increase the efficiency of the radiologist and provide diagnostic and therapeutic radiologic procedures to patients. NMAAs are being used in medical imaging but little literature is available on current roles in clinical practice. More research is needed to assess the exact procedures and duties being performed by these medical imaging physician extenders.

  7. Natural Language Processing Techniques for Extracting and Categorizing Finding Measurements in Narrative Radiology Reports.

    PubMed

    Sevenster, M; Buurman, J; Liu, P; Peters, J F; Chang, P J

    2015-01-01

    Accumulating quantitative outcome parameters may contribute to constructing a healthcare organization in which outcomes of clinical procedures are reproducible and predictable. In imaging studies, measurements are the principal category of quantitative para meters. The purpose of this work is to develop and evaluate two natural language processing engines that extract finding and organ measurements from narrative radiology reports and to categorize extracted measurements by their "temporality". The measurement extraction engine is developed as a set of regular expressions. The engine was evaluated against a manually created ground truth. Automated categorization of measurement temporality is defined as a machine learning problem. A ground truth was manually developed based on a corpus of radiology reports. A maximum entropy model was created using features that characterize the measurement itself and its narrative context. The model was evaluated in a ten-fold cross validation protocol. The measurement extraction engine has precision 0.994 and recall 0.991. Accuracy of the measurement classification engine is 0.960. The work contributes to machine understanding of radiology reports and may find application in software applications that process medical data.

  8. Radiology employees' quality of work life.

    PubMed

    Dargahi, Hussein; Changizi, Vahid; Jazayeri Gharabagh, Elaheh

    2012-01-01

    Quality of work Life (QWL) originates from interactions between employees' needs and relative organizational resources. QWL is aimed to improve and retain employees' satisfaction, productivity and effectiveness of all organizations. A cross-sectional descriptive study was conducted among 15 Tehran University of Medical Sciences. A Cross-Sectional, descriptive study was conducted among 15 Tehran University of Medical Sciences' Hospitals' Radiology Departments' Employees by QWL questionnaire. Respondents were asked to express their attitudes about a range of key factors as the most important issues impacting their QWL. The data was collected and analyzed by SPSS version 15 software. Most of the respondents indicated that they were unsatisfied and very unsatisfied with key factors of their QWL. Comparison of QWL key factors of TUMS radiology employees with the other countries indicated that most of the employees are unsatisfied with their poor QWL factors. We hope, the implications of these findings deliberate to improve QWL within each of TUMS hospitals radiology departments and also be relevant and value to policymakers of healthcare organizations in Iran. © 2012 Tehran University of Medical Sciences. All rights reserved.

  9. Screening of microalgae for integral biogas slurry nutrient removal and biogas upgrading by different microalgae cultivation technology.

    PubMed

    Wang, Xue; Bao, Keting; Cao, Weixing; Zhao, Yongjun; Hu, Chang Wei

    2017-07-14

    The microalgae-based technology has been developed to reduce biogas slurry nutrients and upgrade biogas simultaneously. In this work, five microalgal strains named Chlorella vulgaris, Scenedesmus obliquus, Selenastrum capricornutum, Nitzschia palea, and Anabaena spiroides under mono- and co-cultivation were used for biogas upgrading. Optimum biogas slurry nutrient reduction could be achieved by co-cultivating microalgae (Chlorella vulgaris, Scenedesmus obliquus, and Nitzschia palea) with fungi using the pelletization technology. In addition, the effects of different ratio of mixed LED light wavelengths applying mixed light-emitting diode during algae strains and fungi co-cultivation on CO 2 and biogas slurry nutrient removal efficiency were also investigated. The results showed that the COD (chemical oxygen demand), TN (total nitrogen), and TP (total phosphorus) removal efficiency were 85.82 ± 5.37%, 83.31 ± 4.72%, and 84.26 ± 5.58%, respectively at red: blue = 5:5 under the co-cultivation of S. obliquus and fungi. In terms of biogas upgrading, CH 4 contents were higher than 90% (v/v) for all strains, except the co-cultivation with S. obliquus and fungi at red: blue = 3:7. The results indicated that co-cultivation of microalgae with fungi under mixed light wavelengths treatments was most successful in nutrient removal from wastewater and biogas upgrading.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piekarski, D.; Brad, D.

    This report is about a work effort where the overall objectives were to establish a methodology and approach for selected transmission and distribution (T&D) grid modernization; monitor the results; and report on the findings, recommendations, and lessons learned. The work reported addressed T&D problems and solutions, related reliability issues, equipment and operation upgrades, and respective field testing.

  11. Work Life Improvements for Home Care Workers: Impact and Feasibility.

    ERIC Educational Resources Information Center

    Feldman, Penny Hollander

    1993-01-01

    Evaluated four work life demonstration projects designed to upgrade home aide employment, reduce turnover, and increase continuity of care. Found that projects reduced worker turnover in experimental groups from 10 to 44 percentage points. Where it was measured, continuity of care also significantly improved. Local political, economic, and…

  12. Factors Underlying the Need for In-Service Development Programs in Student Personnel Work.

    ERIC Educational Resources Information Center

    Truitt, John W.

    Definitions, objectives, and concepts of in-service development programs in student personnel work are discussed. A structured, in-service development program p"ovides: (1) continuity for constantly changing staff; (2) enhances orientation and upgrading of new staff; (3) increases staff morale through shared responsibility; (4) encourages…

  13. The Waiter and Waitress Training Manual. Revised Edition.

    ERIC Educational Resources Information Center

    Mitchell, Barbara J.

    This manual is intended for use in pre-employment or upgrading training programs for persons who are planning to work or are presently working in the hotel and restaurant food service industry. Eleven chapters cover interpersonal relationships with employers, fellow employees, and customers; grooming and personal hygiene; sanitary food handling;…

  14. Spending an Evening in the Dark: The Radiology Medical Student Call Experience.

    PubMed

    Monks, Dennis; Pagano, Brian; Hartman, Matthew

    The level of independent decision-making required of a radiology resident, as well as the acuity of studies populating the worklist, differ between the normal workday and a call shift. However, unlike clerkships where call is standard, medical students in radiology typically only have half of the true resident experience. To expose our rotating medical students to what a future career in radiology might actually look like, we implemented a required call shift as part of our medical student curriculum. All rotating third- and fourth-year medical students were assigned a single 3-hour short call shift alongside a radiology resident during the final week of their rotation. Following this shift, students answered questions via anonymous online survey regarding their perceptions of radiology (primary end point) as well as workload and role of radiology in the clinical care of patients (secondary end points). Following medical student call, 63% of students reported a more positive view of radiology as a career. Additionally, 57% felt that radiology residents work as much or more than other specialties while one call, and several students identified communication issues regarding indications or appropriateness of studies. While we hope that this overwhelmingly positive experience will draw more students into radiology as a career, we also believe that many participating medical students will benefit from a greater understanding of what a radiologist׳s job entails, as well as how this may be affected by communication issues or increased utilization of imaging. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. A Comparative Study Using Numerical Methods for Surface X Ray Doses with Conventional and Digital Radiology Equipment in Pediatric Radiology

    NASA Astrophysics Data System (ADS)

    Dan, Posa Ioan; Florin, Georgescu Remus; Virgil, Ciobanu; Antonescu, Elisabeta

    2011-09-01

    The place of the study is a pediatrics clinic which realizes a great variety of emergency, ambulatory ad hospital examinations. The radiology compartment respects work procedures and a system to ensure the quality of X ray examinations. The results show a constant for the programmator of the digital detector machine for the tension applied to the tube. For the screen-film detector machine the applied tension increases proportionally with the physical development of the child considering the trunk thickness.

  16. [Intranet applications in radiology].

    PubMed

    Knopp, M V; von Hippel, G M; Koch, T; Knopp, M A

    2000-01-01

    The aim of the paper is to present the conceptual basis and capabilities of intranet applications in radiology. The intranet, which is the local brother of the internet can be readily realized using existing computer components and a network. All current computer operating systems support intranet applications which allow hard and software independent communication of text, images, video and sound with the use of browser software without dedicated programs on the individual personal computers. Radiological applications for text communication e.g. department specific bulletin boards and access to examination protocols; use of image communication for viewing and limited processing and documentation of radiological images can be achieved on decentralized PCs as well as speech communication for dictation, distribution of dictation and speech recognition. The intranet helps to optimize the organizational efficiency and cost effectiveness in the daily work of radiological departments in outpatients and hospital settings. The general interest in internet and intranet technology will guarantee its continuous development.

  17. NegBio: a high-performance tool for negation and uncertainty detection in radiology reports.

    PubMed

    Peng, Yifan; Wang, Xiaosong; Lu, Le; Bagheri, Mohammadhadi; Summers, Ronald; Lu, Zhiyong

    2018-01-01

    Negative and uncertain medical findings are frequent in radiology reports, but discriminating them from positive findings remains challenging for information extraction. Here, we propose a new algorithm, NegBio, to detect negative and uncertain findings in radiology reports. Unlike previous rule-based methods, NegBio utilizes patterns on universal dependencies to identify the scope of triggers that are indicative of negation or uncertainty. We evaluated NegBio on four datasets, including two public benchmarking corpora of radiology reports, a new radiology corpus that we annotated for this work, and a public corpus of general clinical texts. Evaluation on these datasets demonstrates that NegBio is highly accurate for detecting negative and uncertain findings and compares favorably to a widely-used state-of-the-art system NegEx (an average of 9.5% improvement in precision and 5.1% in F1-score). https://github.com/ncbi-nlp/NegBio.

  18. Togetherness Profit Report

    ERIC Educational Resources Information Center

    Ross, Stan

    1970-01-01

    Traces the evolution of a program of vocational education in which local firms' advice and surplus equipment have upgraded the school's program through teaching aids, summer work experiences for teachers, and curriculum materials. (RH)

  19. Exposure to radiation from the natural radioactivity in Tunisian building materials.

    PubMed

    Gharbi, F; Oueslati, M; Abdelli, W; Samaali, M; Ben Tekaya, M

    2012-12-01

    Building materials can expose public and workers to radiation because of their content of radium, thorium and potassium isotopes. This is why it is very important from the radiological point of view to survey the natural radioactivity content of commonly used building materials in any country. This work consists of the measurement of (226)Ra, (232)Th and (40)K activity concentrations in a variety of commonly used building materials in Tunisia and on the estimation of their radiological hazard. The maximum value of radium equivalent for the studied materials was equal to 169 Bq kg(-1) and corresponds to the clay brick, which is lower than the recommended value of 370 Bq kg(-1). In this work, several radiological indexes were calculated and were found to be under their highest permitted limit.

  20. Haptic interface of web-based training system for interventional radiology procedures

    NASA Astrophysics Data System (ADS)

    Ma, Xin; Lu, Yiping; Loe, KiaFock; Nowinski, Wieslaw L.

    2004-05-01

    The existing web-based medical training systems and surgical simulators can provide affordable and accessible medical training curriculum, but they seldom offer the trainee realistic and affordable haptic feedback. Therefore, they cannot offer the trainee a suitable practicing environment. In this paper, a haptic solution for interventional radiology (IR) procedures is proposed. System architecture of a web-based training system for IR procedures is briefly presented first. Then, the mechanical structure, the working principle and the application of a haptic device are discussed in detail. The haptic device works as an interface between the training environment and the trainees and is placed at the end user side. With the system, the user can be trained on the interventional radiology procedures - navigating catheters, inflating balloons, deploying coils and placing stents on the web and get surgical haptic feedback in real time.

  1. Physician-directed software design: the role of utilization statistics and user input in enhancing HELP results review capabilities.

    PubMed

    Michael, P A

    1993-01-01

    The M.D. Rounds Report program was developed and implemented in June of 1992 as an adjunct to the HELP System at Rex Hospital. The program facilitates rapid access to information on allergies and current medications, laboratory results, radiology reports and therapist notes for a list of patients without physicians having to make additional menu or submenu selections. In planning for an upgrade of the program, utilization statistics and user feedback provided valuable information in terms of frequency of access, features used and unused, and the value of the program as a reporting tool in comparison to other online results reporting applications. A brief description of the functionality of the M.D. Rounds Report, evaluation of the program audit trail and user feedback, planned enhancements to the program, and a discussion of the prototyping and monitoring experience and the impact on future physician subsystem development will be presented.

  2. Data Fusion for a Vision-Radiological System: a Statistical Calibration Algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Enqvist, Andreas; Koppal, Sanjeev; Riley, Phillip

    2015-07-01

    Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development of calibration algorithms for characterizing the fused sensor system as a single entity. There is an apparent need for correcting for a scene deviation from the basic inverse distance-squared law governing the detection rates even when evaluating system calibration algorithms. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked, to which the time-dependent radiological datamore » can be incorporated by means of data fusion of the two sensors' output data. (authors)« less

  3. The RABiT: a rapid automated biodosimetry tool for radiological triage. II. Technological developments.

    PubMed

    Garty, Guy; Chen, Youhua; Turner, Helen C; Zhang, Jian; Lyulko, Oleksandra V; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Lawrence Yao, Y; Brenner, David J

    2011-08-01

    Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. The RABiT analyses fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cut-off dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day.

  4. REVIEW OF THE RADNET AIR MONITORING NETWORK ...

    EPA Pesticide Factsheets

    RadNet, formerly known as ERAMS, has been operating since the 1970's, monitoring environmental radiation across the country, supporting responses to radiological emergencies, and providing important information on background levels of radiation in the environment. The original purpose of the system was to monitor fallout from weapons testing. Even though upgrades to and reconfiguration of the system have been planned for some time, the events of 9/11/01 gave impetus to a thorough upgrade of RadNet, primarily directed at providing more timely data and covering a larger portion of the nation's population. Moreover, the demands upon RadNet are now based upon homeland security support in addition to existing EPA monitoring responsibilities. Beginning in FY05 and continuing into FY13 up to135 near real-time air monitors will be put into operation across the country to provide decision making-data to EPA officials. Data will be transmitted from the monitors in all 50 states to a central database at the National Air and Radiation Environmental Laboratory (NAREL) in Montgomery, Alabama. The data will then be assessed and verified and made available to federal and state officials and, eventually, the public. A data flow model is being constructed to provide the most effective and efficient use of verified data obtained from the new radNet system The objective of the near-real time air monitoring component of RadNet is to provide verified decision-making data to fed

  5. The RABiT: A Rapid Automated Biodosimetry Tool For Radiological Triage. II. Technological Developments

    PubMed Central

    Garty, Guy; Chen, Youhua; Turner, Helen; Zhang, Jian; Lyulko, Oleksandra; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Yao, Y. Lawrence; Brenner, David J.

    2011-01-01

    Purpose Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. Materials and methods The RABiT analyzes fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cutoff dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. Results We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Conclusions Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day. PMID:21557703

  6. X-ray intensity and source size characterizations for the 25 kV upgraded Manson source at Sandia National Laboratories

    NASA Astrophysics Data System (ADS)

    Loisel, G.; Lake, P.; Gard, P.; Dunham, G.; Nielsen-Weber, L.; Wu, M.; Norris, E.

    2016-11-01

    At Sandia National Laboratories, the x-ray generator Manson source model 5 was upgraded from 10 to 25 kV. The purpose of the upgrade is to drive higher characteristics photon energies with higher throughput. In this work we present characterization studies for the source size and the x-ray intensity when varying the source voltage for a series of K-, L-, and M-shell lines emitted from Al, Y, and Au elements composing the anode. We used a 2-pinhole camera to measure the source size and an energy dispersive detector to monitor the spectral content and intensity of the x-ray source. As the voltage increases, the source size is significantly reduced and line intensity is increased for the three materials. We can take advantage of the smaller source size and higher source throughput to effectively calibrate the suite of Z Pulsed Power Facility crystal spectrometers.

  7. Electron Accelerators for Research at the Frontiers of Nuclear Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartline, Beverly; Grunder, Hermann

    1986-10-01

    Electron accelerators for the frontiers of nuclear physics must provide high duty factor (gte 80) for coincidence measurements; few-hundred-MeV through few-GeV energy for work in the nucleonic, hadronic, and confinement regimes; energy resolution of ~ 10 -4; and high current (gte 100 zA). To fulfill these requirements new machines and upgrades of existing ones are being planned or constructed. Representative microtron-based facilities are the upgrade of MAMI at the University of Mainz (West Germany), the proposed two-stage cascade microtron at the University of Illinois (U.S.A.), and the three-stage Troitsk ``polytron'' (USSR). Representative projects to add pulse stretcher rings to existingmore » linacs are the upgrades at MIT-Bates (U.S.A.) and at NIKHEF-K (Netherlands). Recent advances in superconducting rf technology, especially in cavity design and fabrication, have made large superconducting cw linacs become feasible. Recirculating superconducting cw linacs are under construc« less

  8. Environmental impact assessment as a complement of life cycle assessment. Case study: Upgrading of biogas.

    PubMed

    Morero, Betzabet; Rodriguez, María B; Campanella, Enrique A

    2015-08-01

    This work presents a comparison between an environmental impact assessment (EIA) and a life cycle assessment (LCA) using a case study: upgrading of biogas. The upgrading of biogas is studied using three solvents: water, physical solvent and amine. The EIA follows the requirements of the legislation of Santa Fe Province (Argentina), and the LCA follows ISO 14040. The LCA results showed that water produces a minor impact in most of the considered categories whereas the high impact in the process with amines is the result of its high energy consumptions. The positive results obtained in the EIA (mainly associated with the cultural and socioeconomic components) make the project feasible and all the negative impacts can be mitigated by preventive and remedial measures. From the strengths and weaknesses of each tool, it is inferred that the EIA is a procedure that can complement the LCA. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. The radiologic technologists' health study in South Korea: study design and baseline results.

    PubMed

    Lee, Won Jin; Ha, Mina; Hwang, Seung-sik; Lee, Kyoung-Mu; Jin, Young-Woo; Jeong, Meeseon; Jun, Jae Kwan; Cha, Eun Shil; Ko, Yousun; Choi, Kyung-Hwa; Lee, Jung-Eun

    2015-08-01

    To describe the study design, methods, and baseline results of a prospective cohort of radiologic technologists which we have initiated in South Korea. The cohort participants were enrolled through a self-administered questionnaire survey administered from April 2012 to May 2013. Survey data were linked with radiation dosimetry, a cancer registry, and health insurance data by personal identification numbers. A nationwide representative survey was also conducted using a stratified random sampling design with face-to-face interviews. A total of 12,387 radiologic technologists were enrolled, which accounted for approximately 63% of all diagnostic radiologic technologists working in South Korea. For nationwide survey, 585 workers were interviewed using the detailed questionnaire, and buccal cells were also collected by scraping the inside of the cheek. The majority of study subjects were under 50-year-old and male workers. The average annual effective dose of radiation declined both men (from 2.75 to 1.43 mSv) and women (from 1.34 to 0.95 mSv) over the period of 1996-2011. A total of 99 cancers (66 cancers in men and 33 in women) were reported from 1992 to 2010. The standardized incidence ratio of all cancer combined was significantly lower in men (SIR = 0.75, 95% CI 0.58-0.96) than general population, but the ratios for thyroid cancer were significantly higher than expected among both men and women. This cohort provides comprehensive information on work activities and health status of diagnostic radiologic technologists. In addition, the nationwide representative sample provides unique opportunities compared with previous radiologic technologist studies.

  10. 40 CFR 35.930-1 - Types of projects.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... assistance awarded solely for the acquisition of eligible land, the following provisions are deferred until... required to train and upgrade waste treatment works operations and maintenance personnel and for the costs...

  11. 40 CFR 35.930-1 - Types of projects.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... assistance awarded solely for the acquisition of eligible land, the following provisions are deferred until... required to train and upgrade waste treatment works operations and maintenance personnel and for the costs...

  12. 40 CFR 35.930-1 - Types of projects.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... assistance awarded solely for the acquisition of eligible land, the following provisions are deferred until... required to train and upgrade waste treatment works operations and maintenance personnel and for the costs...

  13. 40 CFR 35.930-1 - Types of projects.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... assistance awarded solely for the acquisition of eligible land, the following provisions are deferred until... required to train and upgrade waste treatment works operations and maintenance personnel and for the costs...

  14. 40 CFR 35.930-1 - Types of projects.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... assistance awarded solely for the acquisition of eligible land, the following provisions are deferred until... required to train and upgrade waste treatment works operations and maintenance personnel and for the costs...

  15. Home-based radiology transcription and a productivity pay plan.

    PubMed

    Kerr, K

    1997-01-01

    Shands Hospital in Gainesville, Fla., decided to evaluate the way it provided transcription services in its radiology department. It identified four goals: increased productivity, decreased operating expense, finding much needed space in the radiology department and increasing employee morale. The department performs 165,000 procedures annually, with 66 radiologists, 29 faculty, and 37 residents and fellows on staff. Six FTEs comprised the transcription pool in the radiology department, with transcription their only duty. Transcriptionists were paid an hourly rate based on their years of service, not their productivity. Evaluation and measurement studies were undertaken by the hospital's management systems engineering department. The transcriptionists' hours were then changed to provide coverage during the periods of heaviest dictation. The productivity level of the transcription staff was also measured and various methods of measurement reviewed. The goal was a pure incentive pay plan that would reward employees for every increase in productivity. The incentive pay plan was phased in over a three-month period. Transcriptionists were paid for work performed, with no base pay beyond minimum wage. The move to home-based transcription was planned. The necessary equipment was identified and various issues specific to working at home were addressed. Approximately six months later, the transcriptionists were set up to work at home. The astounding results achieved are presented: 28% increase in productivity, operational cost savings exceeding $25,000 and a space savings of 238 square feet.

  16. NCRP Program Area Committee 3: Nuclear and Radiological Security and Safety [Update on the Ncrp Program Area Committee 3 Activities: Nuclear And Radiological Security and Safety

    DOE PAGES

    Ansari, Armin; Buddemeier, Brooke

    2018-02-01

    The National Council on Radiation Protection and Measurements (NCRP) Program Area Committee (PAC) 3 covers the broad subject of nuclear and radiological security and safety and provides guidance and recommendations for response to nuclear and radiological incidents of both an accidental and deliberate nature. In 2017, PAC 3 Scientific Committee 3-1 completed the development of Guidance for Emergency Responder Dosimetry, and began development of a companion commentary on operational aspects of that guidance. PAC 3 members also organized the technical program for the 2017 Annual Meeting of the NCRP on “Assessment of National Efforts in Emergency Preparedness for Nuclear Terrorism:more » Is There a Need for Realignment to Close Remaining Gaps.” Based on discussions and presentations at the annual meeting, PAC 3 is working to develop a commentary on the subject that could serve as a roadmap for focusing our national efforts on the most pressing needs for preparing the nation for nuclear and radiological emergencies. PAC 3 is also engaged in active discussions, exploring the landscape of priority issues for its future activities. Lastly, an important consideration in this discussion is the extent of NCRP’s present and potential future resources to support the work of its scientific committees.« less

  17. NCRP Program Area Committee 3: Nuclear and Radiological Security and Safety [Update on the Ncrp Program Area Committee 3 Activities: Nuclear And Radiological Security and Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ansari, Armin; Buddemeier, Brooke

    The National Council on Radiation Protection and Measurements (NCRP) Program Area Committee (PAC) 3 covers the broad subject of nuclear and radiological security and safety and provides guidance and recommendations for response to nuclear and radiological incidents of both an accidental and deliberate nature. In 2017, PAC 3 Scientific Committee 3-1 completed the development of Guidance for Emergency Responder Dosimetry, and began development of a companion commentary on operational aspects of that guidance. PAC 3 members also organized the technical program for the 2017 Annual Meeting of the NCRP on “Assessment of National Efforts in Emergency Preparedness for Nuclear Terrorism:more » Is There a Need for Realignment to Close Remaining Gaps.” Based on discussions and presentations at the annual meeting, PAC 3 is working to develop a commentary on the subject that could serve as a roadmap for focusing our national efforts on the most pressing needs for preparing the nation for nuclear and radiological emergencies. PAC 3 is also engaged in active discussions, exploring the landscape of priority issues for its future activities. Lastly, an important consideration in this discussion is the extent of NCRP’s present and potential future resources to support the work of its scientific committees.« less

  18. Barriers to enrolment into a professional upgrading programme for enrolled nurses in Kenya

    PubMed Central

    Lakati, Alice; Ngatia, Peter; Mbindyo, Caroline; Mukami, Diana; Oywer, Elizabeth

    2012-01-01

    Introduction Nurses play a key role in the provision of health care. Over 70% of the nurses in Kenya are Enrolled Community Health Nurses (ECHNs). AMREF in partnership with Nursing Council of Kenya and the Ministry of Health pioneered an eLearning Nurse Upgrading Programme. The purpose of this study was to identify barriers that hindered enrolment into the programme. Methods A descriptive cross-sectional design was used. A sample of 532 ECHNs was interviewed from four provinces. Data was collected using a pre-tested self administered questionnaire. Analysis was done using SPSS computer software. Descriptive statistics were calculated for all variables and chi-square tests used to determine variables that were associated with enrolment. Mann Whitney U-test was used for continuous variables. Results A third (29.7%) of the nurses were from Rift Valley province and 17.9% from Coast. Majority (75%) were from public health facilities. The mean age of the nurses was 40.6 years. The average monthly income was KES 22,497.68 (USD 294). Awareness of the upgrading programme was high (97%) among the nurses. The cost of fees was the main (74.1%) barrier to enrolment in all the provinces and across all the health facilities. The type of health facility was significantly (p < 0.05) associated with enrolment. Nurses from faith-based health facilities were less likely to have enrolled. Conclusion Awareness of the upgrading programme is high. The cost of upgrading programme, age and working in a faith-based health facility are the main barriers to enrolment. Intervention that fund nurses to upgrade would increase nurse enrolment. PMID:23467717

  19. Contribution for new genetic markers of rheumatoid arthritis activity and severity: sequencing of the tumor necrosis factor-alpha gene promoter.

    PubMed

    Fonseca, João Eurico; Cavaleiro, João; Teles, José; Sousa, Elsa; Andreozzi, Valeska L; Antunes, Marília; Amaral-Turkman, Maria A; Canhão, Helena; Mourão, Ana F; Lopes, Joana; Caetano-Lopes, Joana; Weinmann, Pamela; Sobral, Marta; Nero, Patrícia; Saavedra, Maria J; Malcata, Armando; Cruz, Margarida; Melo, Rui; Braña, Araceli; Miranda, Luis; Patto, José V; Barcelos, Anabela; da Silva, José Canas; Santos, Luís M; Figueiredo, Guilherme; Rodrigues, Mário; Jesus, Herberto; Quintal, Alberto; Carvalho, Teresa; da Silva, José A Pereira; Branco, Jaime; Queiroz, Mário Viana

    2007-01-01

    The objective of this study was to assess whether clinical measures of rheumatoid arthritis activity and severity were influenced by tumor necrosis factor-alpha (TNF-alpha) promoter genotype/haplotype markers. Each patient's disease activity was assessed by the disease activity score using 28 joint counts (DAS28) and functional capacity by the Health Assessment Questionnaire (HAQ) score. Systemic manifestations, radiological damage evaluated by the Sharp/van der Heijde (SvdH) score, disease-modifying anti-rheumatic drug use, joint surgeries, and work disability were also assessed. The promoter region of the TNF-alpha gene, between nucleotides -1,318 and +49, was sequenced using an automated platform. Five hundred fifty-four patients were evaluated and genotyped for 10 single-nucleotide polymorphism (SNP) markers, but 5 of these markers were excluded due to failure to fall within Hardy-Weinberg equilibrium or to monomorphism. Patients with more than 10 years of disease duration (DD) presented significant associations between the -857 SNP and systemic manifestations, as well as joint surgeries. Associations were also found between the -308 SNP and work disability in patients with more than 2 years of DD and radiological damage in patients with less than 10 years of DD. A borderline effect was found between the -238 SNP and HAQ score and radiological damage in patients with 2 to 10 years of DD. An association was also found between haplotypes and the SvdH score for those with more than 10 years of DD. An association was found between some TNF-alpha promoter SNPs and systemic manifestations, radiological progression, HAQ score, work disability, and joint surgeries, particularly in some classes of DD and between haplotypes and radiological progression for those with more than 10 years of DD.

  20. Contribution for new genetic markers of rheumatoid arthritis activity and severity: sequencing of the tumor necrosis factor-alpha gene promoter

    PubMed Central

    Fonseca, João Eurico; Cavaleiro, João; Teles, José; Sousa, Elsa; Andreozzi, Valeska L; Antunes, Marília; Amaral-Turkman, Maria A; Canhão, Helena; Mourão, Ana F; Lopes, Joana; Caetano-Lopes, Joana; Weinmann, Pamela; Sobral, Marta; Nero, Patrícia; Saavedra, Maria J; Malcata, Armando; Cruz, Margarida; Melo, Rui; Braña, Araceli; Miranda, Luis; Patto, José V; Barcelos, Anabela; da Silva, José Canas; Santos, Luís M; Figueiredo, Guilherme; Rodrigues, Mário; Jesus, Herberto; Quintal, Alberto; Carvalho, Teresa; da Silva, José A Pereira; Branco, Jaime; Queiroz, Mário Viana

    2007-01-01

    The objective of this study was to assess whether clinical measures of rheumatoid arthritis activity and severity were influenced by tumor necrosis factor-alpha (TNF-α) promoter genotype/haplotype markers. Each patient's disease activity was assessed by the disease activity score using 28 joint counts (DAS28) and functional capacity by the Health Assessment Questionnaire (HAQ) score. Systemic manifestations, radiological damage evaluated by the Sharp/van der Heijde (SvdH) score, disease-modifying anti-rheumatic drug use, joint surgeries, and work disability were also assessed. The promoter region of the TNF-α gene, between nucleotides -1,318 and +49, was sequenced using an automated platform. Five hundred fifty-four patients were evaluated and genotyped for 10 single-nucleotide polymorphism (SNP) markers, but 5 of these markers were excluded due to failure to fall within Hardy-Weinberg equilibrium or to monomorphism. Patients with more than 10 years of disease duration (DD) presented significant associations between the -857 SNP and systemic manifestations, as well as joint surgeries. Associations were also found between the -308 SNP and work disability in patients with more than 2 years of DD and radiological damage in patients with less than 10 years of DD. A borderline effect was found between the -238 SNP and HAQ score and radiological damage in patients with 2 to 10 years of DD. An association was also found between haplotypes and the SvdH score for those with more than 10 years of DD. An association was found between some TNF-α promoter SNPs and systemic manifestations, radiological progression, HAQ score, work disability, and joint surgeries, particularly in some classes of DD and between haplotypes and radiological progression for those with more than 10 years of DD. PMID:17408492

  1. Radiology workstation design for the medical intensive care unit.

    PubMed

    Moise, Adrian; Atkins, Stella M

    2002-01-01

    The "one-size-fits-all" approach for radiology workstation design is not good enough anymore. While most of the picture archiving and communication system (PACS) vendors are racing to add more features to the radiology workstation, there is little interest in addressing the specific needs of other hospital departments. Significant delays in the availability of radiology reports are often caused by the fact there is not enough Intensive Care Unit (ICU) volume to justify a full time radiologist. Consequently, the radiologist assigned to cover the ICU exams, most likely working from a different building, will read the ICU exams only at certain times, depending on the limitations for remote image availability. This paper addresses the main objectives in designing a digital radiology workstation for use in the medical ICU (MICU), requiring enhancements to current PACS systems. Our suggestions for PACS improvement follow the ICU digital workflow starting with the transfer of the images from the modality, continuing with the presentation of the radiology examination to different types of users (radiologists or ICU staff), up to the creation and distribution of the reports.

  2. Building the body: active learning laboratories that emphasize practical aspects of anatomy and integration with radiology.

    PubMed

    Zumwalt, Ann C; Lufler, Rebecca S; Monteiro, Joseph; Shaffer, Kitt

    2010-01-01

    Active learning exercises were developed to allow advanced medical students to revisit and review anatomy in a clinically meaningful context. In our curriculum, students learn anatomy two to three years before they participate in the radiology clerkship. These educational exercises are designed to review anatomy content while highlighting its relevance to the study of radiology. Laboratory exercises were developed using inexpensive materials in the form of hands-on stations designed for use by students working together in small groups. Station exercises include model building, exploring relevant radiological imaging, and practicing clinical techniques. Students are encouraged to move from abstract conceptualization of the anatomy using models to applying knowledge to living tissues by using a portable ultrasound to explore superficial anatomy on each other. Stations are designed to integrate knowledge and reemphasize concepts in different contexts, so that upon completion students have a reinforced understanding of the three-dimensional anatomy of the region in question, the appearance of the anatomy on radiological images, and an appreciation of the relevance of the anatomy to radiological procedures. (c) 2010 American Association of Anatomists.

  3. Double-double bend achromat cell upgrade at the Diamond Light Source: From design to commissioning

    NASA Astrophysics Data System (ADS)

    Bartolini, R.; Abraham, C.; Apollonio, M.; Bailey, C. P.; Cox, M. P.; Day, A.; Fielder, R. T.; Hammond, N. P.; Heron, M. T.; Holdsworth, R.; Kay, J.; Martin, I. P. S.; Mhaskar, S.; Miller, A.; Pulampong, T.; Rehm, G.; Rial, E. C. M.; Rose, A.; Shahveh, A.; Singh, B.; Thomson, A.; Walker, R. P.

    2018-05-01

    Diamond has recently successfully commissioned a major change in the lattice consisting of the substitution of a standard double-bend achromat (DBA) cell with a modified four-bend achromat (4BA) cell called "double-double bend achromat" (DDBA). This work stems from the original studies initiated in 2012 towards a Diamond upgrade and provides the benefit of an additional straight section in the ring available for insertion devices. This paper reviews the DDBA design and layout, the implications for technical subsystems, the associated engineering challenges and the main results of the commissioning completed in April 2017.

  4. Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab

    DOE PAGES

    Friend, M.; Parno, D.; Benmokhtar, F.; ...

    2012-06-01

    The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped Gd 2SiO 5 crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.

  5. Another Powerful Spacewalk on This Week @NASA – January 13, 2017

    NASA Image and Video Library

    2017-01-13

    Outside the International Space Station, Expedition 50 Commander Shane Kimbrough of NASA and Flight Engineer Thomas Pesquet of the European Space Agency conducted a spacewalk on Jan. 13, to complete an upgrade that included installing adapter plates and hooking up electrical connections for six new lithium-ion batteries, which were delivered to the station in December. Kimbrough and fellow NASA astronaut Peggy Whitson began the upgrade work during a spacewalk on Jan. 6. Also, NASA at SciTech 2017, Testing How the SLS Deals with Shock, New Earth Science Field Experiments, and NASA Sees Storms Affecting the Western U.S.

  6. Investing in Florida's Economy. Florida's School-to-Work Continuum. Second Edition.

    ERIC Educational Resources Information Center

    Florida State Dept. of Education, Tallahassee. Div. of Vocational, Adult, and Community Education.

    This booklet describes programs designed to offer a comprehensive system to improve Florida's work force. Through these programs, students and workers in Florida are prepared to enter the labor force, attend technical training programs, enroll in other postsecondary programs, or upgrade their skills on the job. The following are discussed: the…

  7. 40 CFR 35.935-17 - Training facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.935-17 Training facility. If assistance has been provided for the construction of a treatment works required to train and upgrade waste treatment personnel under §§ 35.930-1(b) and 35.920-3(e), the grantee must...

  8. 40 CFR 35.935-17 - Training facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.935-17 Training facility. If assistance has been provided for the construction of a treatment works required to train and upgrade waste treatment personnel under §§ 35.930-1(b) and 35.920-3(e), the grantee must...

  9. Asynchronous Online Peer Assistance: Telephone Messages of Encouragement in Post Licensure Nursing Programs

    ERIC Educational Resources Information Center

    Melrose, Sherri; Swettenham, Steve

    2012-01-01

    Peer assistance activities can strengthen online learning environments. And yet, like other professional adult learners, working post licensure nurses attending university part time to upgrade their credentials may have limited interest in student-to-student interaction. Some intentionally choose asynchronous self-paced courses so they can work on…

  10. Career Adaptability and Intention to Leave among ICT Professionals: An Exploratory Study

    ERIC Educational Resources Information Center

    Omar, Safiah; Noordin, Fauziah

    2013-01-01

    Adaptability was found to be one of the important aspects for employees in order for them to survive in their career especially to those in the ICT industry. The ICT work nature involved with consistent work changes, intensive creative thinking, and advanced technological upgrading. Although organizations supposed to encourage career adaptability…

  11. Energy-Efficient Homes (Done Right)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2017-07-31

    Home energy upgrade measures allow individuals to enjoy a safe, comfortable, and energy-efficient home. But how do you know if the work is done right? Learn how the U.S Department of Energy and its National Renewable Energy Laboratory are working to ensure that energy efficient measures are being installed correctly across the United States.

  12. Educational treasures in radiology: a free online program for Radiology Boards preparation.

    PubMed

    Talanow, Roland

    2011-01-01

    An objective tool is desired, which optimally prepares for Radiology boards examination. Such program should prepare examinees with pertinent radiological contents and simulations as expected in the real examination. Many countries require written boards examinations for Radiology certification eligibility. No objective measure exists to tell if the examinee is ready to pass the exam or not. Time pressure and computer environment might be unfamiliar to examinees. Traditional preparation lectures don't simulate the "real" Radiology exam because they don't provide the special environment with multiple choice questions and timing. This online program consists of 4 parts. The entry section allows to create questions with additional fields for comprehensive information. Sections include Pediatrics/Mammography/GI/IR/Nucs/Thoracic/Musculoskeletal/GU/Neuro/Ultrasound/Cardiac/OB/GYN and Miscellaneous. Experienced radiologists and educators evaluate and release/delete these entries in the administrator section. In the exam section users can create (un)timed customized exams for individual needs and learning pace. Exams can either include all sections or only specific sections to gear learning towards areas with weaker performance. Comprehensive statistics unveil the user's strengths and weaknesses to help focussing on "weak" areas. In the search section a comprehensive search and review can be performed by searching the entire database for keywords/topics or only searching within specific sections. www.RadiologyBoards.org is a new working concept of Radiology boards preparation to detect and improve the examinee's weaknesses and finally to increase the examinee's confidence level for the final exam. It is beneficial for Radiology residents and also board certified radiologists to refresh/maintain radiological knowledge.

  13. KSC-2013-2892

    NASA Image and Video Library

    2013-06-25

    CAPE CANAVERAL, Fla. – Inside the Vehicle Assembly Building at NASA’s Kennedy Space Center in Florida, technicians position equipment and forklifts as work continues to install new roller shaft bearings in crawler-transporter 2, or CT-2. Work continues in high bay 2 to upgrade CT-2. The modifications are designed to ensure CT-2’s ability to transport launch vehicles currently in development, such as the agency’s Space Launch System, to the launch pad. The Ground Systems Development and Operations Program office at Kennedy is overseeing the upgrades. For more than 45 years the crawler-transporters were used to transport the mobile launcher platform and the Apollo-Saturn V rockets and, later, space shuttles to Launch Pads 39A and B. For more information, visit: http://www.nasa.gov/exploration/systems/ground/crawler-transporter_bearings.html. Photo credit: NASA/Jim Grossmann

  14. Biomass Direct Liquefaction Options. TechnoEconomic and Life Cycle Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tews, Iva J.; Zhu, Yunhua; Drennan, Corinne

    The purpose of this work was to assess the competitiveness of two biomass to transportation fuel processing routes, which were under development in Finland, the U.S. and elsewhere. Concepts included fast pyrolysis (FP), and hydrothermal liquefaction (HTL), both followed by hydrodeoxygenation, and final product refining. This work was carried out as a collaboration between VTT (Finland), and PNNL (USA). The public funding agents for the work were Tekes in Finland and the Bioenergy Technologies Office of the U.S. Department of Energy. The effort was proposed as an update of the earlier comparative technoeconomic assessment performed by the IEA Bioenergy Directmore » Biomass Liquefaction Task in the 1980s. New developments in HTL and the upgrading of the HTL biocrude product triggered the interest in reinvestigating this comparison of these biomass liquefaction processes. In addition, developments in FP bio-oil upgrading had provided additional definition of this process option, which could provide an interesting comparison.« less

  15. Strategy development for anticipating and handling a disruptive technology.

    PubMed

    Chan, Stephen

    2006-10-01

    The profession of radiology has greatly benefited from the introduction of new imaging technologies throughout its history. Therefore, it would seem reasonable for radiologists to believe that the emergence of a new imaging technology can generally be foreseen with sufficient advance notice to allow the appropriate levels of time, effort, and money to be devoted toward incorporating it into radiology practice. However, in his seminal work, Christiansen characterized a new form of technologic innovation, known as "disruptive technology," whose emergence often heralds the replacement of market leaders in an industry by competitors who are quicker in adopting and deploying the new technology. This article briefly describes the phenomenon of disruptive technology and addresses the challenges that organizations face in dealing with disruptive technology. The article raises 4 questions about the future of radiology: (1) Are health care and radiology vulnerable to disruptive technology? (2) What kinds of change may be in store for the radiology profession? (3) Can the radiology profession prepare itself to recognize and respond to a disruptive innovation among a group of new imaging technologies? and (4) How should a radiology organization decide whether to invest significant resources in a potentially disruptive technology? This article addresses these questions by reviewing key insights from leading "gurus" in the fields of competitive strategy and technology management and applying them to radiology. This illustrates how and why (despite past successes) the radiology profession may still have a blind spot in recognizing and handling disruptive technologies.

  16. Radiological anatomy - evaluation of integrative education in radiology.

    PubMed

    Dettmer, S; Schmiedl, A; Meyer, S; Giesemann, A; Pabst, R; Weidemann, J; Wacker, F K; Kirchhoff, T

    2013-09-01

    Evaluation and analysis of the integrative course "Radiological Anatomy" established since 2007 at the Medical School Hannover (MHH) in comparison with conventional education. Anatomy and radiology are usually taught separately with a considerable time lag. Interdisciplinary teaching of these associated subjects seems logical for several reasons. Therefore, the integrative course "Radiological Anatomy" was established in the second year of medical education, combining these two closely related subjects. This interdisciplinary course was retrospectively evaluated by consideration of a student questionnaire and staff observations. The advantages and disadvantages of integrative teaching in medical education are discussed. The course ratings were excellent (median 1; mean 1.3 on a scale of 1 to 6). This is significantly (p < 0.001) better than the average of all evaluated courses in the respective term (grade 2.8). The course improved the anatomical comprehension (90 %) and the students stated that the topics were relevant for their future medical education (90 %). Furthermore, interest in the subject's anatomy and radiology increased during the course (88 %). According to the students' suggestions the course was enhanced by a visitation in the Department of Radiology and the additional topic central nervous system. Integrative teaching of anatomy and radiology was well received by the students. Both, anatomical and radiological comprehension and the motivation to learn were improved. However, it should be considered, that the amount of work and time required by the teaching staff is considerably increased compared to traditional teaching. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Herbert M. Parker: Publications and contributions to radiological and health physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kathren, R.L.; Baalman, R.W.; Bair, W.J.

    For more than a half century, Herbert M. Parker was a leading force in radiological physics. As a scientist, he was codeveloper of a systematic dosimetry scheme for implant therapy and the innovative proposer of radiological units with unambiguous physical and biological bases. He made seminal contributions to the development of scientifically based radiation protection standards and, as an administrator and manager as well as scientist, helped the Hanford Laboratories to achieve preeminance in several areas, including radiation biology, radioactive waste disposal, and environmental radioactivity. This volume brings together, sometimes from obscure sources, his works.

  18. [Development of clinical radiology in the Military field therapy Department of the Military Medical Academy (the 90th anniversary of the birth of G. I. Alekseyev)].

    PubMed

    Khalimov, Iu Sh; Vlasenko, A N; Matveev, S Iu

    2012-08-01

    On August 18, 2012, 90 years have passed since the birth of the former head of the Military field therapy Department of The Military-Medical Academy named after S. M. Kirov--the main radiologist of the Ministry of Defence of Russian Federation, the corresponding member of the Soviet Union Academy of Medical Science and the Russian Academy of Medical Science, the major- general of a medical service G. I. Alekseyev, who had been working in the department since its foundation till the last day of his life. Being the head of the department for twelve years, G. I. Alekseyev made a considerable contribution to the formation and development of native military radiology, training of medical and scientific skilled specialists. Professor G. I. Alekseyev's scientific ideas and views in the sphere of radiology were realized and developed in further educational, research and medical work of the department. Nowadays the staff of the Military field therapy Department remembers G. I. Alekseyev with special gratitude and appreciation and successfully realizes his ideas and plans in work.

  19. Successful Strategies for Rapidly Upgrading PTC Windchill 9.1 to Windchill 10.1 on a Light Budget

    NASA Technical Reports Server (NTRS)

    Shearrow, Charles A.

    2013-01-01

    Topics covered include: The Frugal Times Historical Upgrade Process; Planning for Possible Constraints; PTC Compatibility Matrix; In-Place Upgrade Process; Pre-Upgrade Activities; Upgrade Activities; Post Upgrade Activities; Results of the Upgrade; Tips for an Upgrade On a Shoestring Budget.

  20. Graduates' Transition from Study to Employment of Radiologic Technology Graduates of the Lyceum University of the Philippines--Batangas

    ERIC Educational Resources Information Center

    Valdez, Anacleta P.

    2012-01-01

    A ten-year tracer study of Radiologic Technology graduates of Lyceum of the Philippines University SY 1997-2007 using a survey-structured questionnaire was conducted to examine retrospective contribution of their education to their current work. The objectives of the study included the determination of graduates' job-placement profile; how…

  1. Standardization of pediatric uroradiological terms: a multidisciplinary European glossary.

    PubMed

    Vivier, Pierre-Hugues; Augdal, Thomas A; Avni, Fred E; Bacchetta, Justine; Beetz, Rolf; Bjerre, Anna K; Blickman, Johan; Cochat, Pierre; Coppo, Rosana; Damasio, Beatrice; Darge, Kassa; El-Ghoneimi, Alaa; Hoebeke, Piet; Läckgren, Göran; Leclair, Marc-David; Lobo, Maria-Luisa; Manzoni, Gianantonio; Marks, Stephen D; Mattioli, Girolamo; Mentzel, Hans-Joachim; Mouriquand, Pierre; Nevéus, Tryggve; Ntoulia, Aikaterini; Ording-Muller, Lil-Sofie; Oswald, Josef; Papadopoulou, Frederica; Porcellini, Gabriella; Ring, Ekkehard; Rösch, Wolfgang; Teixeira, Ana F; Riccabona, Michael

    2018-02-01

    To promote the standardization of nephro-uroradiological terms used in children, the European Society of Paediatric Radiology uroradiology taskforce wrote a detailed glossary. This work has been subsequently submitted to European experts in pediatric urology and nephrology for discussion and acceptance to improve the quality of radiological reports and communication between different clinicians involved in pediatric urology and nephrology.

  2. Offshore teleradiology.

    PubMed

    Bradley, William G

    2004-04-01

    Radiologists are responsible for providing prompt emergency radiology interpretations 24 hours a day, every day of the year. As a result of the increasing use of multidetector computed tomography, emergency radiology has increased significantly in volume over the past 5 years. Simultaneously, radiologists are working harder during the day because of the workforce shortage. Although teleradiology services located in the continental United States have been providing efficient coverage until recently, they are now having increasing difficulty recruiting radiologists who are willing to work at night. Addressing this problem is "offshore teleradiology." With the increasing use of several enabling technologies--Digital Imaging and Communication in Medicine, the picture archiving and communication system, and the Internet-it is now possible to cover a domestic radiology practice at night from any location in the world where it is daytime. Setting up such a practice is nontrivial, however. The radiologists must all be American trained and certified by the American Board of Radiology. They must have medical licenses in every state and privileges at every hospital they cover. This article describes some of the details involved in setting up an offshore teleradiology practice. It also attempts to make a financial case for using such a practice, particularly in the current economic environment.

  3. Building a leadership team that works.

    PubMed

    Blomenberg, Emily M

    2005-01-01

    Radiology administrators often are challenged to do more with less. In today's fast-paced work environment, leaders must be creative. They must surround themselves with good people in order to successfully achieve their organizations' goals. Once a radiology administrator is satisfied and comfortable that he or she has, the right staff involved, a leadership team can be formally establislished. Howard Regional Health System established an Imaging Services Leadership Team with a vision to provide leaders for the staff to "follow," just as team members learn from the radiology administrator. In addition, team members are vital in assisting the radiology administrator in managing the department The process of building the team consisted of 3 steps: selecting team members (the most challenging and time-consuming component), formalizing a functional team, and putting the team into action. Finding the right people, holding regular meetings, and making those team meetings meaningful are keys to a successful leadership team. The implementation of the team has had a positive effect on imaging services: the number of procedures has increased, the team is used as a communication tool for front-line staff, front-line staff are becoming more comfortable with making decisions.

  4. Upgrade of optical WDM transport systems introducing linerates at 40 Gbit/s per channel

    NASA Astrophysics Data System (ADS)

    Schneiders, Malte; Vorbeck, Sascha; Aust, Nora

    2006-10-01

    Driven by high growth rates of internet traffic the question of upgrading existing optical metro-, regio- and long haul transport networks introducing 40 Gbit/s/λ is one of the most important questions today and in the near future. Current WDM Systems in photonic networks are commonly operated at linerates of 2.5 and 10 Gbit/s/λ. Induced by market analyses and the historical development of transport systems some work has already been carried out to evaluate update scenarios from 10 to 40 Gbit/s channel data rates. Due to the inherent quadruplication of the bandwidth per channel, limitations due to linear and non-linear transmission impairments become stronger resulting in a highly increased complexity of link engineering, potentially increasing the capital and operational expenditures. A lot of work is therefore in progress, which targets at the relaxation of constraints for 40 Gbit/s transmission to find the most efficient upgrade strategies. One approach towards an increased robustness against signal distortions is the introduction of more advanced modulation formats. Different modulation schemes show strongly different optical WDM transmission characteristics. The choice of the appropriate format does not only depend on the technical requirements, but also on economical considerations as an increased transmitter- and receiver-complexity will drive the transponder price. This article presents investigations on different modulation formats for the upgrade of existing metro-/ regio and long haul transport networks. Tolerances and robustness against the main degrading effects dispersion, noise and nonlinearities are considered together with mitigation strategies like the adaptation of dispersion maps. Results from numerical simulations are provided for some of the most promising modulation formats like NRZ, RZ, CS-RZ, Optical Duobinary and DPSK.

  5. Real-Time Electronic Dashboard Technology and Its Use to Improve Pediatric Radiology Workflow.

    PubMed

    Shailam, Randheer; Botwin, Ariel; Stout, Markus; Gee, Michael S

    The purpose of our study was to create a real-time electronic dashboard in the pediatric radiology reading room providing a visual display of updated information regarding scheduled and in-progress radiology examinations that could help radiologists to improve clinical workflow and efficiency. To accomplish this, a script was set up to automatically send real-time HL7 messages from the radiology information system (Epic Systems, Verona, WI) to an Iguana Interface engine, with relevant data regarding examinations stored in an SQL Server database for visual display on the dashboard. Implementation of an electronic dashboard in the reading room of a pediatric radiology academic practice has led to several improvements in clinical workflow, including decreasing the time interval for radiologist protocol entry for computed tomography or magnetic resonance imaging examinations as well as fewer telephone calls related to unprotocoled examinations. Other advantages include enhanced ability of radiologists to anticipate and attend to examinations requiring radiologist monitoring or scanning, as well as to work with technologists and operations managers to optimize scheduling in radiology resources. We foresee increased utilization of electronic dashboard technology in the future as a method to improve radiology workflow and quality of patient care. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Turbo FRMAC 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fulton, John; Gallagher, Linda K.; Whitener, Dustin

    The Turbo FRMAC (TF) software automates the calculations described in volumes 1-3 of "The Federal Manual for Assessing Environmental Data During a Radiological Emergency" (2010 version). This software automates the process of assessing radiological data during a Federal Radiological Emergency. The manual upon which the software is based is unclassified and freely available on the Internet. TF takes values generated by field samples or computer dispersion models and assesses the data in a way which is meaningful to a decision maker at a radiological emergency; such as, do radiation values exceed city, state, or federal limits; should the crops bemore » destroyed or can they be utilized; do residents need to be evacuated, sheltered in place, or should another action taken. The software also uses formulas generated by the EPA, FDA, and other federal agencies to generate field observable values specific to the radiological event that can be used to determine where regulatory limit values are exceeded. In addition to these calculations, TF calculates values which indicate how long an emergency worker can work in the contaminated area during a radiological emergency, the dose received from drinking contaminated water or milk, the dose from eating contaminated food, the does expected down or upwind of a given field sample, along with a significant number of other similar radiological health values.« less

  7. RADIOLOGY EDUCATION: A PILOT STUDY TO ASSESS KNOWLEDGE OF MEDICAL STUDENTS REGARDING IMAGING IN TRAUMA.

    PubMed

    Siddiqui, Saad; Saeed, Muhammad Anwar; Shah, Noreen; Nadeem, Naila

    2015-01-01

    Trauma remains one of the most frequent presentations in emergency departments. Imaging has established role in setting of acute trauma with ability to identify potentially fatal conditions. Adequate knowledge of health professionals regarding trauma imaging is vital for improved healthcare. In this work we try to assess knowledge of medical students regarding imaging in trauma as well as identify most effective way of imparting radiology education. This cross-sectional pilot study was conducted at Aga Khan University Medical College & Khyber Girls Medical College, to assess knowledge of medical students regarding imaging protocols practiced in initial management of trauma patients. Only 40 & 20% respectively were able to identify radiographs included in trauma series. Very few had knowledge of correct indication for Focused abdominal sonography in trauma. Clinical radiology rotation was reported as best way of learning radiology. Change in curricula & restructuring of clinical radiology rotation structure is needed to improve knowledge regarding Trauma imaging.

  8. Complications of Non-Operating Room Procedures: Outcomes From the National Anesthesia Clinical Outcomes Registry.

    PubMed

    Chang, Beverly; Kaye, Alan D; Diaz, James H; Westlake, Benjamin; Dutton, Richard P; Urman, Richard D

    2015-04-07

    This study examines the impact of procedural locations and types of anesthetics on patient outcomes in non-operating room anesthesia (NORA) locations. The National Anesthesia Clinical Outcomes Registry database was examined to compare OR to NORA anesthetic complications and patient demographics. The National Anesthesia Clinical Outcomes Registry database was examined for all patient procedures from 2010 to 2013. A total of 12,252,846 cases were analyzed, with 205 practices contributing information, representing 1494 facilities and 7767 physician providers. Cases were separated on the basis of procedure location, OR, or NORA. Subgroup analysis examined outcomes from specific subspecialties. Non-OR anesthesia procedures were performed on a higher percentage of patients older than 50 years (61.92% versus 55.56%, P < 0.0001). Monitored anesthesia care (MAC) (20.15%) and sedation (2.05%) were more common in NORA locations. The most common minor complications were postoperative nausea and vomiting (1.06%), inadequate pain control (1.01%), and hemodynamic instability (0.62%). The most common major complications were serious hemodynamic instability (0.10%) and upgrade of care (0.10%). There was a greater incidence of complications in cardiology and radiology locations. Overall mortality was higher in OR versus NORA (0.04% versus 0.02%, P < 0.0001). Subcategory analysis showed increased incidence of death in cardiology and radiology locations (0.05%). Non-OR anesthesia procedures have lower morbidity and mortality rates than OR procedures, contrary to some previously published studies. However, the increased complication rates in both the cardiology and radiology locations may need to be the target of future safety investigations. Providers must ensure proper monitoring of patients, and NORA locations need to be held to the same standard of care as the main operating room. Further studies need to identify at-risk patients and procedures that may predispose patients to complications.

  9. Interventional Procedures Outside of the Operating Room: Results From the National Anesthesia Clinical Outcomes Registry.

    PubMed

    Chang, Beverly; Kaye, Alan D; Diaz, James H; Westlake, Benjamin; Dutton, Richard P; Urman, Richard D

    2018-03-01

    This study examines the impact of procedural locations and types of anesthetics on patient outcomes in non-operating room anesthesia (NORA) locations. The National Anesthesia Clinical Outcomes Registry database was examined to compare OR to NORA anesthetic complications and patient demographics. The National Anesthesia Clinical Outcomes Registry database was examined for all patient procedures from 2010 to 2013. A total of 12,252,846 cases were analyzed, with 205 practices contributing information, representing 1494 facilities and 7767 physician providers. Cases were separated on the basis of procedure location, OR, or NORA. Subgroup analysis examined outcomes from specific subspecialties. NORA procedures were performed on a higher percentage of patients older than 50 years (61.92% versus 55.56%, P < 0.0001). Monitored anesthesia care (MAC) (20.15%) and sedation (2.05%) were more common in NORA locations. The most common minor complications were postoperative nausea and vomiting (1.06%), inadequate pain control (1.01%), and hemodynamic instability (0.62%). The most common major complications were serious hemodynamic instability (0.10%) and upgrade of care (0.10%). There was a greater incidence of complications in cardiology and radiology locations. Overall mortality was higher in OR versus NORA (0.04% versus 0.02%, P < 0.0001). Subcategory analysis showed increased incidence of death in cardiology and radiology locations (0.05%). NORA procedures have lower morbidity and mortality rates than OR procedures, contrary to some previously published studies. However, the increased complication rates in both the cardiology and radiology locations may need to be the target of future safety investigations. Providers must ensure proper monitoring of patients, and NORA locations need to be held to the same standard of care as the main operating room. Further studies need to identify at-risk patients and procedures that may predispose patients to complications.

  10. Medical isotope identification with large mobile detection systems

    NASA Astrophysics Data System (ADS)

    Mukhopadhyay, Sanjoy; Maurer, Richard

    2012-10-01

    The Remote Sensing laboratory (RSL) of National Security Technologies Inc. has built an array of large (5.08 - cm x 10.16 - cm x 40.6 - cm) thallium doped sodium iodide (NaI: Tl) scintillators to locate and screen gamma-ray emitting radioisotopes that are of interests to radiological emergency responders [1]. These vehicle mounted detectors provide the operators with rapid, simple, specific information for radiological threat assessment. Applications include large area inspection, customs inspection, border protection, emergency response, and monitoring of radiological facilities. These RSL mobile units are currently being upgraded to meet the Defense Threat Reduction Agency mission requirements for a next-generation system capable of detecting and identifying nuclear threat materials. One of the challenging problems faced by these gamma-ray detectors is the unambiguous identification of medical isotopes like 131I (364.49 keV [81.7%], 636.99 keV [7.17%]), 99Tcm (140.51 keV [89.1%]) and 67Ga (184.6 keV [19.7%], 300.2 [16.0%], 393.5 [4.5%] that are used in radionuclide therapy and often have overlapping gamma-ray energy regions of interest (ROI). The problem is made worse by short (about 5 seconds) acquisition time of the spectral data necessary for dynamic mobile detectors. This article describes attempts to identify medical isotopes from data collected from this mobile detection system in a short period of time (not exceeding 5 secs) and a large standoff distance (typically 10 meters) The mobile units offer identification capabilities that are based on hardware auto stabilization of the amplifier gain. The 1461 keV gamma-energy line from 40K is tracked. It uses gamma-ray energy windowing along with embedded mobile Gamma Detector Response and Analysis Software (GADRAS) [2] simultaneously to deconvolve any overlapping gamma-energy ROIs. These high sensitivity detectors are capable of resolving complex masking scenarios and exceed all ANSI N42.34 (2006) requirements for the identification of bare, shielded and multiple isotopes.

  11. The Stability of Factors Influencing the Choice of Medical Specialty Among Medical Students and Postgraduate Radiology Trainees.

    PubMed

    Yen, Adam J; Webb, Emily M; Jordan, Eric J; Kallianos, Kimberly; Naeger, David M

    2018-06-01

    To investigate whether general psychological motivating factors that guide career selection of a medical specialty differ over the course of medical school and to compare differences in motivating factors among students choosing "controllable" lifestyle specialties, students choosing "uncontrollable" lifestyle specialties, and a cohort of radiology residents. An anonymous survey was distributed to first- through fourth-year medical students and radiology residents at a single institution. Participants were asked to select their top three of seven factors that most influenced their choice of medical specialty. Fourth-year students were asked to designate the specialty to which they had applied. The survey was distributed to 259 students and 47 radiology residents with a response rate of 93.8% (243 of 259) and 95.7% (45 of 47), respectively. The top three factors indicated by medical students were finding the daily work fulfilling, work-life balance, and interest in the subject. These top three factors were common to all medical student classes and did not differ between students choosing "controllable" versus "uncontrollable" fields. The factors uncommonly selected were similar personality to others in the field, attending income, competitiveness or prestige, and job market conditions. For radiology residents, the top three motivating factors were the same as for medical students. Three out of seven motivating factors were universally important to trainees, regardless of their stage of medical training or their selection of a controllable versus uncontrollable lifestyle specialty. These data suggest the variety of career choices made by students may not derive from differing underlying values. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  12. Using Technology with Classroom Instruction that Works. Second Edition

    ERIC Educational Resources Information Center

    Kuhn, Matt; Hubbell, Elizabeth R.; Pitler, Howard

    2012-01-01

    If you've upgraded to the second edition of the landmark book "Classroom Instruction That Works," you need this companion guide to help you use technology to support research-based instruction. The authors follow the revised Instructional Planning Guide that makes it easier for you to know when to emphasize each of the instructional strategies,…

  13. Occupational musculoskeletal pain in cardiac sonographers compared to peer employees: a multisite cross-sectional study.

    PubMed

    Orme, Nicholas M; Geske, Jeffrey B; Pislaru, Sorin V; Askew, John Wells; Lennon, Ryan J; Lewis, Bradley R; Rihal, Charanjit S; Pellikka, Patricia A; Singh, Mandeep

    2016-11-01

    The purpose of this study was to compare the prevalence and impact of work-related musculoskeletal pain in cardiac sonographers to a large control group of peer employees with similar demographics. Cardiac sonographers are known to have high levels of occupational musculoskeletal pain. Comparative studies with other employees within cardiology/radiology departments have never been performed. An electronic survey was administered to Mayo Clinic employees at six major patient care facilities in four different states. There were 2682 employees within the departments of cardiology and radiology who were contacted, and 1532 (57%) completed the survey. After excluding those who wore protective lead aprons, 517 employees comprised the control group and 66 cardiac sonographers made up the study group. Cardiac sonographers reported work-related musculoskeletal pain more frequently than the control group (88% vs 40%; P<.001). This association persisted after multivariable adjustment for age, sex, body mass index, length of current employment, and history of preexisting musculoskeletal pain (OR 11.6; [95% CI 5.32, 25.5]; P<.001). Cardiac sonographers sought medical care for their work-related pain more often (55% vs 21%; P<.001) and missed more work due to pain (35% vs 12%, P<.001). In a secondary analysis, cardiac sonographers also experienced more work-related musculoskeletal pain than nurses, technicians, and physicians working in the interventional laboratory who regularly wear a protective lead apron (P<.001). In this multisite cross-sectional study, cardiac sonographers experienced significantly more work-related pain and missed more work due to pain than peer employees within cardiology/radiology departments. © 2016, Wiley Periodicals, Inc.

  14. Marketing and Distributive Education. Community/Work-Based Programs. An Instructor's Guide to Program Strategies. Cooperative Vocational Education; Vocational Work Experience Education; Community Classroom.

    ERIC Educational Resources Information Center

    Holzkamper, Charlot

    Designed for use in high school and adult education programs, this manual was developed to help marketing and distributive education teachers to develop or upgrade community/work-based programs; and to assist teachers who operate these programs to use legal operational practices and to meet the occupational needs of their students and communities.…

  15. Understanding and Applying the Concept of Value Creation in Radiology.

    PubMed

    Larson, David B; Durand, Daniel J; Siegal, Daniel S

    2017-04-01

    The concept of value in radiology has been strongly advocated in recent years as a means of advancing patient care and decreasing waste. This article explores the concept of value creation in radiology and offers a framework for how radiology practices can create value according to the needs of their referring clinicians. Value only exists in the eyes of a customer. We propose that the primary purpose of diagnostic radiology is to answer clinical questions using medical imaging to help guide management of patient care. Because they are the direct recipient of this service, we propose that referring clinicians are the direct customers of a radiology practice and patients are indirect customers. Radiology practices create value as they understand and fulfill their referring clinicians' needs. To narrow those needs to actionable categories, we propose a framework consisting of four major dimensions: (1) how quickly the clinical question needs to be answered, (2) the degree of specialization required to answer the question, (3) how often the referring clinician uses imaging, and (4) the breadth of imaging that the referring clinician uses. We further identify three major settings in which referring clinicians utilize radiological services: (1) emergent or urgent care, (2) primary care, and (3) specialty care. Practices best meet these needs as they engage with their referring clinicians, create a shared vision, work together as a cohesive team, structure the organization to meet referring clinicians' needs, build the tools, and continually improve in ways that help referring clinicians care for patients. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. TRENCADIS--a WSRF grid MiddleWare for managing DICOM structured reporting objects.

    PubMed

    Blanquer, Ignacio; Hernandez, Vicente; Segrelles, Damià

    2006-01-01

    The adoption of the digital processing of medical data, especially on radiology, has leaded to the availability of millions of records (images and reports). However, this information is mainly used at patient level, being the extraction of information, organised according to administrative criteria, which make the extraction of knowledge difficult. Moreover, legal constraints make the direct integration of information systems complex or even impossible. On the other side, the widespread of the DICOM format has leaded to the inclusion of other information different from just radiological images. The possibility of coding radiology reports in a structured form, adding semantic information about the data contained in the DICOM objects, eases the process of structuring images according to content. DICOM Structured Reporting (DICOM-SR) is a specification of tags and sections to code and integrate radiology reports, with seamless references to findings and regions of interests of the associated images, movies, waveforms, signals, etc. The work presented in this paper aims at developing of a framework to efficiently and securely share medical images and radiology reports, as well as to provide high throughput processing services. This system is based on a previously developed architecture in the framework of the TRENCADIS project, and uses other components such as the security system and the Grid processing service developed in previous activities. The work presented here introduces a semantic structuring and an ontology framework, to organise medical images considering standard terminology and disease coding formats (SNOMED, ICD9, LOINC..).

  17. Architecture of next-generation information management systems for digital radiology enterprises

    NASA Astrophysics Data System (ADS)

    Wong, Stephen T. C.; Wang, Huili; Shen, Weimin; Schmidt, Joachim; Chen, George; Dolan, Tom

    2000-05-01

    Few information systems today offer a clear and flexible means to define and manage the automated part of radiology processes. None of them provide a coherent and scalable architecture that can easily cope with heterogeneity and inevitable local adaptation of applications. Most importantly, they often lack a model that can integrate clinical and administrative information to aid better decisions in managing resources, optimizing operations, and improving productivity. Digital radiology enterprises require cost-effective solutions to deliver information to the right person in the right place and at the right time. We propose a new architecture of image information management systems for digital radiology enterprises. Such a system is based on the emerging technologies in workflow management, distributed object computing, and Java and Web techniques, as well as Philips' domain knowledge in radiology operations. Our design adapts the approach of '4+1' architectural view. In this new architecture, PACS and RIS will become one while the user interaction can be automated by customized workflow process. Clinical service applications are implemented as active components. They can be reasonably substituted by applications of local adaptations and can be multiplied for fault tolerance and load balancing. Furthermore, it will provide powerful query and statistical functions for managing resources and improving productivity in real time. This work will lead to a new direction of image information management in the next millennium. We will illustrate the innovative design with implemented examples of a working prototype.

  18. An ion accelerator for undergraduate research and teaching

    NASA Astrophysics Data System (ADS)

    Monce, Michael

    1997-04-01

    We have recently upgraded our 400kV, single beam line ion accelerator to a 1MV, multiple beam line machine. This upgrade has greatly expanded the opportunities for student involvement in the laboratory. We will describe four areas of work in which students now participate. The first is the continuing research being conducted in excitations produced in ion-molecule collisions, which recently involved the use of digital imaging. The second area of research now opened up by the new accelerator involves PIXE. We are currently beginning a cross disciplinary study of archaeological specimens using PIXE and involving students from both anthropology and physics. Finally, two beam lines from the accelerator will be used for basic work in nuclear physics: Rutherford scattering and nuclear resonances. These two nuclear physics experiments will be integrated into our sophomore-junior level, year-long course in experimental physics.

  19. Monte Carlo generators for hadron physics: updates on PHOKHARA and EKHARA generators

    NASA Astrophysics Data System (ADS)

    Czyż, Henryk; Kisza, Patrycja; Tracz, Szymon

    2017-04-01

    A short review of current upgrades of the PHOKHARA and EKHARA generators is presented together with a report on the work in progress. The upgrades are based on a newly constructed model of the χci - γ* - γ* and χci - J/ψ* - γ* form factors. Within this model predictions were made for the electronic widths of χc1 and χc2 and, based on the event generators results, cross sections e+e- → χc1 (→ J/ψ(→ μ+μ-)γ), e+e-→ e+e-χc1 and e+e-→ e+e-χc1 (→ J/ψ(→ μ+μ-)γ). Work supported in part by the Polish National Science Centre, grant number DEC-2012/07/B/ST2/03867 and German Research Foundation DFG under Contract No. Collaborative Research Center CRC-1044.

  20. Image Sharing in Radiology-A Primer.

    PubMed

    Chatterjee, Arindam R; Stalcup, Seth; Sharma, Arjun; Sato, T Shawn; Gupta, Pushpender; Lee, Yueh Z; Malone, Christopher; McBee, Morgan; Hotaling, Elise L; Kansagra, Akash P

    2017-03-01

    By virtue of its information technology-oriented infrastructure, the specialty of radiology is uniquely positioned to be at the forefront of efforts to promote data sharing across the healthcare enterprise, including particularly image sharing. The potential benefits of image sharing for clinical, research, and educational applications in radiology are immense. In this work, our group-the Association of University Radiologists (AUR) Radiology Research Alliance Task Force on Image Sharing-reviews the benefits of implementing image sharing capability, introduces current image sharing platforms and details their unique requirements, and presents emerging platforms that may see greater adoption in the future. By understanding this complex ecosystem of image sharing solutions, radiologists can become important advocates for the successful implementation of these powerful image sharing resources. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  1. Standardization of pediatric uroradiological terms: A multidisciplinary European glossary.

    PubMed

    Vivier, Pierre-Hugues; Augdal, Thomas A; Avni, Fred E; Bacchetta, Justine; Beetz, Rolf; Bjerre, Anna K; Blickman, Johan; Cochat, Pierre; Coppo, Rosana; Damasio, Beatrice; Darge, Kassa; El-Ghoneimi, Alaa; Hoebeke, Piet; Läckgren, Göran; Leclair, Marc-David; Lobo, Maria-Luisa; Manzoni, Gianantonio; Marks, Stephen D; Mattioli, Girolamo; Mentzel, Hans-Joachim; Mouriquand, Pierre; Nevéus, Tryggve; Ntoulia, Aikaterini; Ording-Muller, Lil-Sofie; Oswald, Josef; Papadopoulou, Frederica; Porcellini, Gabriella; Ring, Ekkehard; Rösch, Wolfgang; Teixeira, Ana F; Riccabona, Michael

    2017-12-01

    To promote the standardization of nephro-uroradiological terms used in children, the European Society of Pediatric Radiology uroradiology taskforce wrote a detailed glossary. This work has been subsequently submitted to European experts in pediatric urology and nephrology for discussion and acceptance to improve the quality of radiological reports and communication among different clinicians involved in pediatric urology and nephrology. Copyright © 2017. Published by Elsevier Ltd.

  2. Novel Application of FTIR Spectroscopy for the Passive Standoff Detection of Radiological Materials

    DTIC Science & Technology

    2006-08-01

    possibility of applying the long-wave passive standoff detection technique to the identification of radiological materials. This work is based on...infrared (FTIR) radiometry is a well-known technique for detecting and identifying chemical warfare agents. In addition to these potential threats...necessary tools and techniques available for detecting and identifying radioactive products. At present, the main detection techniques depend on methods

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elliott, Douglas C.; Neuenschwander, Gary G.; Hart, Todd R.

    Fast pyrolysis of biomass can be used to produce a raw bio-oil product, which can be upgraded by catalytic hydroprocessing to hydrocarbon liquid products. In this study the upgraded products were distilled to recover light naphtha and oils and to produce a distillation resid with useful properties for coker processing and production of renewable, low-sulfur electrode carbon. For this hydroprocessing work, phase separation of the bio-oil was applied as a preparatory step to concentrate the heavier, more phenolic components thus generating a more amenable feedstock for resid production. Low residual oxygen content products were produced by continuous-flow, catalytic hydroprocessing ofmore » the phase separated bio-oil.« less

  4. Progress on the Design of the Storage Ring Vacuum System for the Advanced Photon Source Upgrade Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stillwell, B.; Billett, B.; Brajuskovic, B.

    2017-06-20

    Recent work on the design of the storage ring vacuum system for the Advanced Photon Source Upgrade project (APS-U) includes: revising the vacuum system design to accommodate a new lattice with reverse bend magnets, modifying the designs of vacuum chambers in the FODO sections for more intense incident synchrotron radiation power, modifying the design of rf-shielding bellows liners for better performance and reliability, modifying photon absorber designs to make better use of available space, and integrated planning of components needed in the injection, extraction and rf cavity straight sections. An overview of progress in these areas is presented.

  5. Time Synchronization Prototype, Server Upgrade Procedure Support and Remote Software Development

    NASA Technical Reports Server (NTRS)

    Sanders, Shania R.

    2014-01-01

    Networks are roadways of communication that connect devices. Like all roadways, there are rules and regulations that govern whatever (information in this case) travels along them. One type of rule that is commonly used is called a protocol. More specifically, a protocol is a standard that specifies how data should be transmitted over a network. The project outlined in this document seeks to implement one protocol in particular, Precision Time Protocol, within the Kennedy Ground Control Subsystem network at Kennedy Space Center. This document also summarizes work completed for server upgrades, remote software developer training and how all three assignments demonstrated the importance of accountability and security.

  6. Preventing tuberculosis in healthcare workers of the radiology department: a Malaysian perspective.

    PubMed

    Tan, Lh; Kamarulzaman, A

    2006-01-01

    Tuberculosis (TB) is a well recognised occupational hazard for healthcare workers (HCWs). Concerns on the safety of healthcare settings in Malaysia was raised following a report of 25 HCWs working in 11 general hospitals in Malaysia who were infected with TB in 2004 being publicised in the media recently. As the disease burden in general is high in Malaysia, due attention should be given to this disease in our healthcare facilities including the radiology department, an often neglected area in TB infection control programmes. This article focuses on the key control measures that can be implemented in radiology departments in a developing country with limited resources.

  7. An honest day's work: pay for performance in a pediatric radiology department.

    PubMed

    Bisset, George S

    2017-06-01

    Compensation models in radiology take a variety of forms, but regardless of practice type, successful models must reward productivity, be simple, and epitomize fairness. The ideal model should also be flexible enough to transition, based upon the changing strategic goals of a department. The plan should be constructed around rewarding the behaviors that the organization values. In this minisymposium article the author presents the value of different types of compensation plans and discusses advantages and disadvantages. Finally, the author presents a pay-for-performance model that has had long-term success at a private-turned-academic practice in pediatric radiology.

  8. Cultivating Future Radiology Educators: Development and Implementation of a Clinician-Educator Track for Residents.

    PubMed

    Mendoza, Dexter; Peterson, Ryan; Ho, Christopher; Harri, Peter; Baumgarten, Deborah; Mullins, Mark E

    2018-05-03

    Effective and dedicated educators are critical to the preservation and advancement of the practice of radiology. The need for innovative and adaptable educators is increasingly being recognized, with several institutions granting academic promotions through clinician-educator tracks. The implementation of resident "clinician-educator tracks" or "teaching tracks" should better prepare residents aspiring to become academic radiologists focused on teaching. In this work, we describe our experience in the development and implementation of a clinician-educator track for diagnostic radiology residents at our institution. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  9. My road on interventional radiology

    PubMed Central

    Li, Yan-Hao

    2010-01-01

    The author tells a story of how he has become an expert of interventional radiotherapy from a graduate of middle school. In his childhood, he wanted to become an astronomer. However, he was forced to go to the countryside as a school graduate. In 1974, he was enrolled as a “worker-peasant-soldier” student in Henan Medical College. After graduated from the college, he was assigned to the Radiology Department of the First Affiliated Hospital of Henan Medical College where he worked hard as an assistant doctor. Then, he was transferred to Nanfang Hospital (Guangzhou, China) where he achieved great successes and thus has become an expert of interventional radiology. PMID:21161028

  10. Completion of the LANSCE Proton Storage Ring Control System Upgrade -- A Successful Integration of EPICS Into a Running Control System

    NASA Astrophysics Data System (ADS)

    Schaller, S. C.; Bjorklund, E. A.; Carr, G. P.; Faucett, J. A.; Oothoudt, M. A.

    1997-05-01

    The Los Alamos Neutron Scattering Center (LANSCE) Proton Storage Ring (PSR) control system upgrade was completed in 1996. In previous work, much of a PDP-11-based control system was replaced with Experimental Physics and Industrial Control System (EPICS) controls. Several parts of the old control system which used a VAX for operator displays and direct access to a CAMAC serial highway still remained. The old system was preserved as a "fallback" if the new EPICS-based system had problems. The control system upgrade completion included conversion of several application programs to EPICS-based operator interfaces, moving some data acquisition hardware to EPICS Input-Output Controllers (IOCs), and the implementation of new gateway software to complete the overall control system interoperability. Many operator interface (OPI) screens, written by LANSCE operators, have been incorporated in the new system. The old PSR control system hardware was removed. The robustness and reliability of the new controls obviated the need for a fallback capability.

  11. Hydrothermal conversion of xylose, glucose, and cellulose under the catalysis of transition metal sulfates.

    PubMed

    Cao, Xuefei; Peng, Xinwen; Sun, Shaoni; Zhong, Linxin; Chen, Wei; Wang, Sha; Sun, Run-Cang

    2015-03-15

    Hydrothermal conversion (HTC) is an important thermochemical process to upgrade low-cost biomass into valuable chemicals or fuels. As compared with non-catalytic HTC, catalytic HTC shows high energy efficiency on biomass upgradation. In this work, the catalytic performances of various transition metal sulfates (Mn(2+), Fe(2+), Fe(3+), Co(2+), Ni(2+), Cu(2+), and Zn(2+)) in the HTCs of xylose, glucose, and cellulose under different conditions were explored. Among these catalysts, Zn(2+) and Ni(2+) showed obvious effects on the conversions of xylose, glucose, and cellulose into lactic acid, while Cu(2+) and Fe(3+), which could significantly accelerate the hydrolysis of cellulose into glucose at 200°C, displayed high efficiency on converting glucose and cellulose into levulinic acid and formic acid at high temperature. Additionally, significant positive correlative relationships among xylose, glucose, and cellulose degradations were observed. This study is helpful for screening appropriate catalysts for biomass upgradation through catalytic HTC of monosaccharide. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Improved methane removal in exhaust gas from biogas upgrading process using immobilized methane-oxidizing bacteria.

    PubMed

    Sun, Meng-Ting; Yang, Zhi-Man; Fu, Shan-Fei; Fan, Xiao-Lei; Guo, Rong-Bo

    2018-05-01

    Methane in exhaust gas from biogas upgrading process, which is a greenhouse gas, could cause global warming. The biofilter with immobilized methane-oxidizing bacteria (MOB) is a promising approach for methane removal, and the selections of inoculated MOB culture and support material are vital for the biofilter. In this work, five MOB consortia were enriched at different methane concentrations. The MOB-20 consortium enriched at the methane concentration of 20.0% (v/v) was then immobilized on sponge and two particle sizes of volcanic rock in biofilters to remove methane in exhaust gas from biogas upgrading process. Results showed that the immobilized MOB performed more admirable methane removal capacity than suspended cells. The immobilized MOB on sponge reached the highest methane removal efficiency (RE) of 35%. The rough surface, preferable hydroscopicity, appropriate pore size and particle size of support material might favor the MOB immobilization and accordingly methane removal. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. ATLAS trigger operations: Upgrades to ``Xmon'' rate prediction system

    NASA Astrophysics Data System (ADS)

    Myers, Ava; Aukerman, Andrew; Hong, Tae Min; Atlas Collaboration

    2017-01-01

    We present ``Xmon,'' a tool to monitor trigger rates in the Control Room of the ATLAS Experiment. We discuss Xmon's recent (1) updates, (2) upgrades, and (3) operations. (1) Xmon was updated to modify the tool written for the three-level trigger architecture in Run-1 (2009-2012) to adapt to the new two-level system for Run-2 (2015-current). The tool takes as input the beam luminosity to make a rate prediction, which is compared with incoming rates to detect anomalies that occur both globally throughout a run and locally within a run. Global offsets are more commonly caught by the predictions based upon past runs, where offline processing allows for function adjustments and fit quality through outlier rejection. (2) Xmon was upgraded to detect local offsets using on-the-fly predictions, which uses a sliding window of in-run rates to make predictions. (3) Xmon operations examples are given. Future work involves further automation of the steps to provide the predictive functions and for alerting shifters.

  14. The upgrade system of BESIII ETOF with MRPC technology

    NASA Astrophysics Data System (ADS)

    Wang, X. Z.; Sun, Y. J.; Li, C.; Heng, Y. K.; Wu, Z.; Cao, P.; Dai, H. L.; Ji, X. L.; Gong, W. X.; Liu, Z.; Luo, X. L.; Sun, W. J.; Wang, S. Y.; Wang, Y.; Yang, R. X.; Ye, M.; Zhao, J. L.

    2016-08-01

    An upgrade, based on Multigap Resistive Plate Chamber (MRPC) technology, of the endcap Time-Of-Flight (ETOF) detector of the Beijing Spectrometer III (BESIII) has been proposed for the replacement of the current scintillator + PMT based ETOF, with the aim of improving the time resolution down to 80 ps sigma. This improvement will enhance the particle identification capability to meet the higher precision requirements of physics. The ETOF system including MRPC modules, Front End Electronics (FEE), CLOCK module, fast control boards and Time to Digital modules (TDIG), has been designed, constructed and parts of the ETOF system have seperately tested. Aiming at examining the quality of entire ETOF system and training the operation of all participated instruments, a cosmic ray test system was built and tested in the laboratory for about three months to guarantee the performance. In this paper the results of the test are presented indicating that the entire ETOF system works well and satisfies the requirements of the upgrade.

  15. Recent Upgrades at the Fermilab Test Beam Facility

    NASA Astrophysics Data System (ADS)

    Rominsky, Mandy

    2016-03-01

    The Fermilab Test Beam Facility is a world class facility for testing and characterizing particle detectors. The facility has been in operation since 2005 and has undergone significant upgrades in the last two years. A second beam line with cryogenic support has been added and the facility has adopted the MIDAS data acquisition system. The facility also recently added a cosmic telescope test stand and improved tracking capabilities. With two operational beam lines, the facility can deliver a variety of particle types and momenta ranging from 120 GeV protons in the primary beam line down to 200 MeV particles in the tertiary beam line. In addition, recent work has focused on analyzing the beam structure to provide users with information on the data they are collecting. With these improvements, the Fermilab Test Beam facility is capable of supporting High Energy physics applications as well as industry users. The upgrades will be discussed along with plans for future improvements.

  16. X-ray intensity and source size characterizations for the 25 kV upgraded Manson source at Sandia National Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loisel, G., E-mail: gploise@sandia.gov; Lake, P.; Gard, P.

    2016-11-15

    At Sandia National Laboratories, the x-ray generator Manson source model 5 was upgraded from 10 to 25 kV. The purpose of the upgrade is to drive higher characteristics photon energies with higher throughput. In this work we present characterization studies for the source size and the x-ray intensity when varying the source voltage for a series of K-, L-, and M-shell lines emitted from Al, Y, and Au elements composing the anode. We used a 2-pinhole camera to measure the source size and an energy dispersive detector to monitor the spectral content and intensity of the x-ray source. As themore » voltage increases, the source size is significantly reduced and line intensity is increased for the three materials. We can take advantage of the smaller source size and higher source throughput to effectively calibrate the suite of Z Pulsed Power Facility crystal spectrometers.« less

  17. Biogas desulfurization and biogas upgrading using a hybrid membrane system--modeling study.

    PubMed

    Makaruk, A; Miltner, M; Harasek, M

    2013-01-01

    Membrane gas permeation using glassy membranes proved to be a suitable method for biogas upgrading and natural gas substitute production on account of low energy consumption and high compactness. Glassy membranes are very effective in the separation of bulk carbon dioxide and water from a methane-containing stream. However, the content of hydrogen sulfide can be lowered only partially. This work employs process modeling based upon the finite difference method to evaluate a hybrid membrane system built of a combination of rubbery and glassy membranes. The former are responsible for the separation of hydrogen sulfide and the latter separate carbon dioxide to produce standard-conform natural gas substitute. The evaluation focuses on the most critical upgrading parameters like achievable gas purity, methane recovery and specific energy consumption. The obtained results indicate that the evaluated hybrid membrane configuration is a potentially efficient system for the biogas processing tasks that do not require high methane recoveries, and allows effective desulfurization for medium and high hydrogen sulfide concentrations without additional process steps.

  18. Radial scars diagnosed on breast core biopsy: Frequency of atypia and carcinoma on excision and implications for management.

    PubMed

    Donaldson, Alana R; Sieck, Leah; Booth, Christine N; Calhoun, Benjamin C

    2016-12-01

    The risk of finding carcinoma in excisions following a core needle biopsy diagnosis of radial scar is not well defined and clinical management is variable. The aim of this study is to determine the frequency of high-risk lesions, ductal carcinoma in situ, and invasive carcinoma in excisions following a core biopsy diagnosis of radial scar. Dedicated breast pathologists and radiologists correlated the histologic and radiologic findings and categorized radial scars as the target lesion or an incidental finding. High-risk lesions were defined as atypical hyperplasia or classical lobular carcinoma in situ. Of the 79 radial scars identified over a 14-year period, 22 were associated with atypia or carcinoma in the core biopsy. Thirty-seven (37) of the 57 benign radial scars underwent excision with benign findings in 30 (81%), high-risk lesions in six (16%), and flat epithelial atypia in one (3%). There were no upgrades to carcinoma. One patient with a benign radial scar developed a 3-mm focus of intermediate-grade estrogen receptor-positive ductal carcinoma in situ in the same quadrant of the ipsilateral breast 72 months after excision. One patient with an incidental un-excised benign radial scar was diagnosed with ductal carcinoma in situ at a separate site of suspicious calcifications. In this series, none of the benign radial scars was upgraded to carcinoma. Radial scar was the targeted lesion in all cases with high-risk lesions on excision. Surgical excision may not be mandatory for patients with benign incidental radial scars on core biopsy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Kinematic optimization of upgrade to the Hobby-Eberly Telescope through novel use of commercially available three-dimensional CAD package

    NASA Astrophysics Data System (ADS)

    Wedeking, Gregory A.; Zierer, Joseph J.; Jackson, John R.

    2010-07-01

    The University of Texas, Center for Electromechanics (UT-CEM) is making a major upgrade to the robotic tracking system on the Hobby Eberly Telescope (HET) as part of theWide Field Upgrade (WFU). The upgrade focuses on a seven-fold increase in payload and necessitated a complete redesign of all tracker supporting structure and motion control systems, including the tracker bridge, ten drive systems, carriage frames, a hexapod, and many other subsystems. The cost and sensitivity of the scientific payload, coupled with the tracker system mass increase, necessitated major upgrades to personnel and hardware safety systems. To optimize kinematic design of the entire tracker, UT-CEM developed novel uses of constraints and drivers to interface with a commercially available CAD package (SolidWorks). For example, to optimize volume usage and minimize obscuration, the CAD software was exercised to accurately determine tracker/hexapod operational space needed to meet science requirements. To verify hexapod controller models, actuator travel requirements were graphically measured and compared to well defined equations of motion for Stewart platforms. To ensure critical hardware safety during various failure modes, UT-CEM engineers developed Visual Basic drivers to interface with the CAD software and quickly tabulate distance measurements between critical pieces of optical hardware and adjacent components for thousands of possible hexapod configurations. These advances and techniques, applicable to any challenging robotic system design, are documented and describe new ways to use commercially available software tools to more clearly define hardware requirements and help insure safe operation.

  20. Rail Modernization Study

    DOT National Transportation Integrated Search

    1987-04-01

    This study summarizes the results of a multi-year assessment of the rail transit and commuter rail systems. The work was based on an earlier study design effort. The purposes of the study were to determine the costs of upgrading and modernizing urban...

  1. Salary Surveys: How to Conduct One in Your Community and Child Care Staff Salary and Working Conditions Survey.

    ERIC Educational Resources Information Center

    Bellm, Dan; Whitebook, Marcy

    Intended for use by child care advocates, this booklet describes ways to gather local information about existing salaries, benefits, and working conditions among child care workers for the purpose of coordinating efforts to upgrade the field. The booklet begins by presenting the rationale behind conducting salary surveys, noting that surveys can…

  2. Youth Apprenticeships: Can They Work in America? EQW Issues Number 3.

    ERIC Educational Resources Information Center

    Tifft, Susan E.

    1992-01-01

    Youth apprenticeships have the potential to address simultaneously two national dilemmas: how to prepare U.S. business and its workers for a high skills future and how to upgrade the academic skills of all students. The highly successful German model may require some modification to work well in the United States. The biggest change may have to…

  3. Toward a Career Ladder in Nursing: Upgrading Nurse's Aides to LPNs Through a Work-Study Program. Final Progress Report.

    ERIC Educational Resources Information Center

    Medical and Health Research Association of New York City, Inc., NY.

    To arrange a program that would enable nurse's aides to undertake licensed practical nurse (LPN) training without financial sacrifice, a 3-year experimental and demonstration project, funded by the Manpower Administration, was conducted in New York City between October 1967 and September 1969. Through a work-study arrangement, 422 nurse's aides in…

  4. Edith (1869-1938) and Florence (1870-1932) Stoney, two Irish sisters and their contribution to radiology during the World War I.

    PubMed

    Guy, Jean M

    2013-05-01

    Edith and Florence Stoney, two sisters born in Dublin and working in London, responded to the summons of suffragists and offered themselves for medical service in World War I. Each had a strong scientific background and experience that they were able to use in setting up and running radiological services in Belgium, France, Serbia and Macedonia. The British War Office was reluctant to employ women doctors but the work Florence and her colleagues achieved persuaded Sir Alfred Keogh that Florence should be the first woman doctor to be employed in a military hospital in England.

  5. The private-practice perspective of the manpower crisis in radiology: greener pastures?

    PubMed

    Swayne, Lawrence C

    2004-11-01

    Rising consumer expectations and a rapidly aging population point to a long-term shortage of all physicians, including radiologists. While attention has been drawn to the escalating manpower crisis in academic radiology departments, the private-practice perspective has been generally overlooked. Although clinical workloads and income are higher in private practice, studies have shown higher satisfaction levels (likely because of a greater variety of work) among academic radiologists. As the distinction between community and teaching hospitals has become increasingly blurred, there is now considerable overlap in the skill sets, sources of job satisfaction, and stresses that are encountered in both practice settings. Perhaps more than at any time in the recent past, diagnostic radiologists in academic and private practice share more in common than any perceived differences. Both groups must work together in concert with the ACR to address the growing manpower shortage, as well as the other challenges that confront diagnostic radiology at the beginning of the 21st century.

  6. Machinery-related deaths: relevance of workplace investigation and antemortem radiological data in reconstructing the fatality.

    PubMed

    Cecchetto, Giovanni; Viel, Guido; De Lotto, Federica; Manara, Renzo; Montisci, Massimo; Zancaner, Silvano; Ferrara, S Davide

    2010-05-01

    Machinery-related fatalities are one of the leading causes of traumatic occupational deaths. In our report, we present the case of a 40-year-old male who suffered a severe head trauma while working in a cut-foam industry and died despite an early craniectomy. The radiological reconstruction of the skull based on preoperative computed tomography scans disclosed a large depressed conical fracture of the left parietal bone. The 3D-reconstruction of the work area, combined with a fit-matching analysis between the machinery and the depressed skull fracture allowed us to conclude that the head was crushed between the sliding bar of the cutting device and the metallic protuberance on the opposite side. The case underlines the importance of a detailed workplace investigation and of a thorough evaluation of all circumstantial, clinical, radiological, and autopsy data in the reconstruction of machinery-related fatalities to identify any possible legal responsibilities of the worker and/or the employer.

  7. Informatics in radiology: automated structured reporting of imaging findings using the AIM standard and XML.

    PubMed

    Zimmerman, Stefan L; Kim, Woojin; Boonn, William W

    2011-01-01

    Quantitative and descriptive imaging data are a vital component of the radiology report and are frequently of paramount importance to the ordering physician. Unfortunately, current methods of recording these data in the report are both inefficient and error prone. In addition, the free-text, unstructured format of a radiology report makes aggregate analysis of data from multiple reports difficult or even impossible without manual intervention. A structured reporting work flow has been developed that allows quantitative data created at an advanced imaging workstation to be seamlessly integrated into the radiology report with minimal radiologist intervention. As an intermediary step between the workstation and the reporting software, quantitative and descriptive data are converted into an extensible markup language (XML) file in a standardized format specified by the Annotation and Image Markup (AIM) project of the National Institutes of Health Cancer Biomedical Informatics Grid. The AIM standard was created to allow image annotation data to be stored in a uniform machine-readable format. These XML files containing imaging data can also be stored on a local database for data mining and analysis. This structured work flow solution has the potential to improve radiologist efficiency, reduce errors, and facilitate storage of quantitative and descriptive imaging data for research. Copyright © RSNA, 2011.

  8. Verification of Minimum Detectable Activity for Radiological Threat Source Search

    NASA Astrophysics Data System (ADS)

    Gardiner, Hannah; Myjak, Mitchell; Baciak, James; Detwiler, Rebecca; Seifert, Carolyn

    2015-10-01

    The Department of Homeland Security's Domestic Nuclear Detection Office is working to develop advanced technologies that will improve the ability to detect, localize, and identify radiological and nuclear sources from airborne platforms. The Airborne Radiological Enhanced-sensor System (ARES) program is developing advanced data fusion algorithms for analyzing data from a helicopter-mounted radiation detector. This detector platform provides a rapid, wide-area assessment of radiological conditions at ground level. The NSCRAD (Nuisance-rejection Spectral Comparison Ratios for Anomaly Detection) algorithm was developed to distinguish low-count sources of interest from benign naturally occurring radiation and irrelevant nuisance sources. It uses a number of broad, overlapping regions of interest to statistically compare each newly measured spectrum with the current estimate for the background to identify anomalies. We recently developed a method to estimate the minimum detectable activity (MDA) of NSCRAD in real time. We present this method here and report on the MDA verification using both laboratory measurements and simulated injects on measured backgrounds at or near the detection limits. This work is supported by the US Department of Homeland Security, Domestic Nuclear Detection Office, under competitively awarded contract/IAA HSHQDC-12-X-00376. This support does not constitute an express or implied endorsement on the part of the Gov't.

  9. Use of In-Situ and Remotely Sensed Snow Observations for the National Water Model in Both an Analysis and Calibration Framework.

    NASA Astrophysics Data System (ADS)

    Karsten, L. R.; Gochis, D.; Dugger, A. L.; McCreight, J. L.; Barlage, M. J.; Fall, G. M.; Olheiser, C.

    2017-12-01

    Since version 1.0 of the National Water Model (NWM) has gone operational in Summer 2016, several upgrades to the model have occurred to improve hydrologic prediction for the continental United States. Version 1.1 of the NWM (Spring 2017) includes upgrades to parameter datasets impacting land surface hydrologic processes. These parameter datasets were upgraded using an automated calibration workflow that utilizes the Dynamic Data Search (DDS) algorithm to adjust parameter values using observed streamflow. As such, these upgrades to parameter values took advantage of various observations collected for snow analysis. In particular, in-situ SNOTEL observations in the Western US, volunteer in-situ observations across the entire US, gamma-derived snow water equivalent (SWE) observations courtesy of the NWS NOAA Corps program, gridded snow depth and SWE products from the Jet Propulsion Laboratory (JPL) Airborne Snow Observatory (ASO), gridded remotely sensed satellite-based snow products (MODIS,AMSR2,VIIRS,ATMS), and gridded SWE from the NWS Snow Data Assimilation System (SNODAS). This study explores the use of these observations to quantify NWM error and improvements from version 1.0 to version 1.1, along with subsequent work since then. In addition, this study explores the use of snow observations for use within the automated calibration workflow. Gridded parameter fields impacting the accumulation and ablation of snow states in the NWM were adjusted and calibrated using gridded remotely sensed snow states, SNODAS products, and in-situ snow observations. This calibration adjustment took place over various ecological regions in snow-dominated parts of the US for a retrospective period of time to capture a variety of climatological conditions. Specifically, the latest calibrated parameters impacting streamflow were held constant and only parameters impacting snow physics were tuned using snow observations and analysis. The adjusted parameter datasets were then used to force the model over an independent period for analysis against both snow and streamflow observations to see if improvements took place. The goal of this work is to further improve snow physics in the NWM, along with identifying areas where further work will take place in the future, such as data assimilation or further forcing improvements.

  10. Radiologic-pathologic Correlation-An Advanced Fourth-year Elective: How We Do It.

    PubMed

    Hartman, Matthew; Silverman, Jan; Spruill, Laura; Hill, Jeanne

    2016-07-01

    Traditionally, the radiology elective has been designed to teach medical students the fundamentals of radiologic interpretation. When questioned, many students state that they want to take a radiology elective so they can "interpret images." For the students on radiology, rotation/elective education was often passive, consisting of didactic conferences and observational shadowing of radiologists as they interpreted images. Students had only a superficial appreciation of how radiologists interacted with clinical services, multidisciplinary teams, and pathology. There was very little emphasis on imaging appropriateness or the most efficient and effective imaging for various clinical problems. With the expansion of numerous imaging modalities and the emphasis on patient-centered care, including imaging safety and dose reduction, it is important to change the focus of radiology education from interpretation to the optimal integration of imaging into clinical medicine. Radiology-pathology (rad path) electives were created at Allegheny General Hospital and the Medical University of South Carolina as a new option to provide a high-quality advanced elective for fourth-year medical students. These electives enable students to correlate radiologic images with gross and microscopic pathology specimens, thus increasing their knowledge and understanding of both. The rad path elective combines aspects of surgery, radiology, and pathology and requires students to be active learners. The implementation of this elective is an exciting work in progress that has been evolving over the past 2 and 4 years at Medical University of South Carolina and Allegheny General Hospital, respectively. We will discuss the historical basis for the elective, the advantages and challenges of having such an integrated course, and some different strategies for creating a rad path elective. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  11. [Case-based interactive PACS learning: introduction of a new concept for radiological education of students].

    PubMed

    Scherer, A; Kröpil, P; Heusch, P; Buchbender, C; Sewerin, P; Blondin, D; Lanzman, R S; Miese, F; Ostendorf, B; Bölke, E; Mödder, U; Antoch, G

    2011-11-01

    Medical curricula are currently being reformed in order to establish superordinated learning objectives, including, e.g., diagnostic, therapeutic and preventive competences. This requires a shifting from traditional teaching methods towards interactive and case-based teaching concepts. Conceptions, initial experiences and student evaluations of a novel radiological course Co-operative Learning In Clinical Radiology (CLICR) are presented in this article. A novel radiological teaching course (CLICR course), which combines different innovative teaching elements, was established and integrated into the medical curriculum. Radiological case vignettes were created for three clinical teaching modules. By using a PC with PACS (Picture Archiving and Communication System) access, web-based databases and the CASUS platform, a problem-oriented, case-based and independent way of learning was supported as an adjunct to the well established radiological courses and lectures. Student evaluations of the novel CLICR course and the radiological block course were compared. Student evaluations of the novel CLICR course were significantly better compared to the conventional radiological block course. Of the participating students 52% gave the highest rating for the novel CLICR course concerning the endpoint overall satisfaction as compared to 3% of students for the conventional block course. The innovative interactive concept of the course and the opportunity to use a web-based database were favorably accepted by the students. Of the students 95% rated the novel course concept as a substantial gain for the medical curriculum and 95% also commented that interactive working with the PACS and a web-based database (82%) promoted learning and understanding. Interactive, case-based teaching concepts such as the presented CLICR course are considered by both students and teachers as useful extensions to the radiological course program. These concepts fit well into competence-oriented curricula.

  12. Radiology: "killer app" for next generation networks?

    PubMed

    McNeill, Kevin M

    2004-03-01

    The core principles of digital radiology were well developed by the end of the 1980 s. During the following decade tremendous improvements in computer technology enabled realization of those principles at an affordable cost. In this decade work can focus on highly distributed radiology in the context of the integrated health care enterprise. Over the same period computer networking has evolved from a relatively obscure field used by a small number of researchers across low-speed serial links to a pervasive technology that affects nearly all facets of society. Development directions in network technology will ultimately provide end-to-end data paths with speeds that match or exceed the speeds of data paths within the local network and even within workstations. This article describes key developments in Next Generation Networks, potential obstacles, and scenarios in which digital radiology can become a "killer app" that helps to drive deployment of new network infrastructure.

  13. Forecasting the Effect of the Change in Timing of the ABR Diagnostic Radiology Examinations: Results of the ACR Survey of Practice Leaders.

    PubMed

    Bluth, Edward I; Muroff, Lawrence R; Cernigliaro, Joseph G; Moore, Arl V; Smith, Geoffrey G; Flug, Jonathan; DeStigter, Kristen K; Allen, Bibb; Thorwarth, William T; Roberts, Anne C

    2015-05-01

    The results of a survey sent to practice leaders in the ACR Practice of Radiology Environment Database show that the majority of responding groups will continue to hire recently trained residents and fellows even though they have been unable to take the final ABR diagnostic radiology certifying examination. However, a significant minority of private practice groups will not hire these individuals. The majority of private practices expect the timing change for the ABR certifying examinations to affect their groups' function. In contrast, the majority of academic medical school practices expect little or no impact. Residents and fellows should not expect work time off or protected time to study for the certifying examination or for their maintenance of certification examinations in the future. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, Nicholas; McCaw, Erica E.; Wright, Kyle A.

    The Global Threat Reduction Initiative (GTRI) reduces and protects vulnerable nuclear and radiological material located at civilian sites worldwide from sabotage, theft or diversion. The GTRI has worked successfully with foreign countries to remove and protect nuclear and radioactive materials including high-activity sources used in medical, commercial, and research applications. There are many barriers to successful bilateral cooperation that must be overcome including language, preconceived perceptions, long distances, and different views on the threat and protection requirements. Successful cooperation is often based on relationships and building trusting relationships takes time. In the case of Dominican Republic, the GTRI first receivedmore » contact in 2008 from the Government of Dominican Republic. They requested cooperation that was similar to the tri-partite cooperation between Colombia, Mexico and the United States. Throughout the region it was widely known that the GTRI’s cooperation with the Government of Colombia was a resounding success resulting in the securing of forty sites; the consolidation of numerous disused/orphan sources at a secure national storage facility; and, the development of a comprehensive approach to security including, inter alia, training and sustainability. The Government of Colombia also showcased this comprehensive approach to thirteen Central American and Caribbean countries at a GTRI regional security conference held in Panama in October 2004. In 2007, Colombia was an integral component of GTRI multi-lateral cooperation initiation in Mexico. As a result, twenty two of Mexico’s largest radioactive sites have been upgraded in the past eighteen months. These two endeavors served as catalysts for cooperation opportunities in the Dominican Republic. Representatives from the Colombian government were aware of GTRI’s interest in initiating cooperation with the Government of Dominican Republic and to facilitate this cooperation, they traveled to the Dominican Republic and provided briefings and presentations which demonstrated its successful cooperation with the GTRI. Shortly after that visit, the Government of Dominican Republic agreed to move forward and requested that the cooperative efforts in Dominican Republic be performed in a tripartite manner, leveraging the skills, experience, and resources of the Colombians, and the financial and technical support of the United States. As a result, two of Dominican Republic’s largest radioactive sites had security upgrades in place within 90 days of the cooperation visit in December 2008.« less

  15. Teaching and Working With Millennial Trainees: Impact on Radiological Education and Work Performance.

    PubMed

    Lourenco, Ana P; Cronan, John J

    2017-01-01

    Many feel that the generational differences encountered with Millennial trainees are novel; the reality is that prior generations have always bemoaned generational differences. This is not a new problem; some of the same things may even have been said about us during our own training! There are a variety of myths and misconceptions about the Millennial generation (also known as Generation Y). In this article we review some of the differences frequently encountered as we educate and work alongside our Millennial colleagues, dispelling some of the myths and misconceptions. With increased understanding of this talented group of individuals, we hope to be more effective teachers and have more successful professional relationships. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Road Weather Systems [SD .WMV (720x480/29fps/25.2 MB)

    DOT National Transportation Integrated Search

    2009-01-01

    Iowas road weather information system at work. The Iowa DOT will install new sensors and upgrades to most road weather information system (RWIS) sites. These include: : color cameras, new precipitation sensors, new speed sensors, revised weathervi...

  17. Denver RTD's computer aided dispatch/automatic vehicle location system : the human factors consequences

    DOT National Transportation Integrated Search

    1999-09-01

    This report documents what happened to employees' work procedures when their employer when their employer installed Computer Aided Disptach/Automatic Vehicle Locator (CAD/AVL) technology to provide real-time surveillance of vehicles and to upgrade ra...

  18. Mammographic findings of women recalled for diagnostic work-up in digital versus screen-film mammography in a population-based screening program.

    PubMed

    Lipasti, Seppo; Anttila, Ahti; Pamilo, Martti

    2010-06-01

    Limited information is available concerning differences in the radiological findings of women recalled for diagnostic work-up in digital mammography (DM) versus screen-film mammography (SFM) screening. To compare the radiological findings, their positive predictive values (PPVs) for cancer and other process indicators of DM screening performed by computed radiography (CR) technology and SFM screening in a population-based program. The material consisted of women, 50-59 years of age, who were invited for screening: 30 153 women with DM in 2007-2008 and 32 939 women with SFM in 1999-2000. The attendance rate was 77.7% (23 440) in the DM arm and 83.8% (27 593) in the SFM arm. In the DM arm, 1.71% of those screened (401) and in the SFM arm 1.59% (438) were recalled for further work-up. The images resulting in the recall were classified as: 1) tumor-like mass, 2) parenchymal distortion/asymmetry, 3) calcifications, and 4) combination of mass and calcifications. The distributions of the various radiological findings and their PPVs for cancer were compared in both study groups. The recall rates, cancer detection rates, test specificities, and PPVs of the DM and SFM groups were also compared. Women were recalled for diagnostic work-up most often due to tumor-like mass. It was more common in SFM (1.08% per woman screened) than in DM (0.93%). The second most common finding was parenchymal distortion and asymmetry, more often in DM (0.58%) than in SFM (0.37%). Calcifications were the third most common finding. DM exposed calcifications more often (0.49%) than SFM (0.26%). The PPVs for cancer of the recalls were higher in DM than in SFM in all subgroups of radiological findings. The test specificities were similar (DM 98.9%, SFM 98.8%). Significantly more cancers were detected by DM (cancer detection rate 0.623% per woman screened, n=146) than by SFM (cancer detection rate 0.406% per woman screened, n=112). The PPVs for cancer of all recalls for diagnostic work-up were significantly higher in DM (36%) than in SFM (26%). In DM women were recalled for diagnostic work-up more often for calcifications, parenchymal distortions, and asymmetries than in SFM. In the case of tumor-like masses, more women were recalled in SFM. DM detected more cancers than SFM, and the PPVs for cancer were higher in DM than in SFM in all subgroups of radiological findings.

  19. Classification of visual signs in abdominal CT image figures in biomedical literature

    NASA Astrophysics Data System (ADS)

    Xue, Zhiyun; You, Daekeun; Antani, Sameer; Long, L. Rodney; Demner-Fushman, Dina; Thoma, George R.

    2014-03-01

    "Imaging signs" are a critical part of radiology's language. They not only are important for conveying diagnosis, but may also aid in indexing radiology literature and retrieving relevant cases and images. Here we report our work towards representing and categorizing imaging signs of abdominal abnormalities in figures in the radiology literature. Given a region-of-interest (ROI) from a figure, our goal was to assign a correct imaging sign label to that ROI from the following seven: accordion, comb, ring, sandwich, small bowel feces, target, or whirl. As training and test data, we created our own "gold standard" dataset of regions containing imaging signs. We computed 2997 feature attributes to represent imaging sign characteristics for each ROI in training and test sets. Following feature selection they were reduced to 70 attributes and were input to a Support Vector Machine classifier. We applied image-enhancement methods to compensate for variable quality of the images in radiology articles. In particular we developed a method for automatic detection and removal of pointers/markers (arrows, arrowheads, and asterisk symbols) on the images. These pointers/markers are valuable for approximately locating ROIs; however, they degrade the classification because they are often (partially) included in the training ROIs. On a test set of 283 ROIs, our method achieved an overall accuracy of 70% in labeling the seven signs, which we believe is a promising result for using imaging signs to search/retrieve radiology literature. This work is also potentially valuable for the creation of a visual ontology of biomedical imaging entities.

  20. Radiologic signs of weapons and munitions: How will noncombatants recognize them?

    PubMed

    Maizlin, Zeev V; Kuruvilla, Mathew; Clement, Jason J; Vos, Patrick M; Brown, Jacqueline A

    2010-08-01

    The purpose of this work was to show the radiologic signs named after weapons and munitions along with their military counterparts to help radiologists recognize these signs, which will allow confident interpretation and diagnosis. Numerous pathologic conditions have classic radiologic manifestations that resemble weapons and ammunition. Most of these signs are highly memorable and easy to recognize. However, the names of the weapons (some of them antique and some not commonly known) may confuse radiologists who are not familiar with the appearance of such weapons as the scimitar, bayonet, or dagger. The value of the signs is reduced if the radiologist is unfamiliar with the appearance of the corresponding weapon.

  1. Learning Cue Phrase Patterns from Radiology Reports Using a Genetic Algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patton, Robert M; Beckerman, Barbara G; Potok, Thomas E

    2009-01-01

    Various computer-assisted technologies have been developed to assist radiologists in detecting cancer; however, the algorithms still lack high degrees of sensitivity and specificity, and must undergo machine learning against a training set with known pathologies in order to further refine the algorithms with higher validity of truth. This work describes an approach to learning cue phrase patterns in radiology reports that utilizes a genetic algorithm (GA) as the learning method. The approach described here successfully learned cue phrase patterns for two distinct classes of radiology reports. These patterns can then be used as a basis for automatically categorizing, clustering, ormore » retrieving relevant data for the user.« less

  2. NIKOLA TESLA AND MEDICINE: 160TH ANNIVERSARY OF THE BIRTH OF THE GENIUS WHO GAVE LIGHT TO THE WORLD - PART I.

    PubMed

    Vucevic, Danijela; Dordevic, Drago; Radosavljevic, Tatjana

    2016-09-01

    The interest in Nikola Tesla, a scientist, physicist, engineer and inventor, is constantly growing. In the millennialong history of human civilization, it is almost impossible to find another person whose life and work has been under so much scrutiny of such a wide range of researchers, medical professionals included. Although Tesla was not primarily dedicated to biomedical research, his work significantly contributed to the development of radiology, and high frequency electrotherapy. This paper deals with the impact of Tesla's work on the development of a new medical branch - radiology. Nikola Tesla and the Discovery of X-ray radiation. Tesla pioneered the use of X-rays for medical purposes, practically laying the foundations of radiology. Namely, since 1887, Tesla periodically experimented with X-rays, at that time still unknown and unnamed, which he called "shadowgraphs". Moreover, at the end of 1894, lie conducted extensive research focusing on X-rays, but unfortunately it was inlerrupted after the fire burning down his laboratory in 1895. In 1896 and 1897, Tesla published ten papers on the biologic effects of X-ray radiation. All his studies on X-rays were experimental. During 1896 and 1897, Tesla continued improving X-ray devices. Apart from this, Tesla was the first to point out the harmful effects of exposure to X-ray radiation on human body. Nikola Tesla was a visionary genius of the future. Tesla's pioneer steps, made more than a century ago in the domain of radiology, are still being used today.

  3. Emotional Wellness of Current Musculoskeletal Radiology Fellows.

    PubMed

    Porrino, Jack; Mulcahy, Michael J; Mulcahy, Hyojeong; Relyea-Chew, Annemarie; Chew, Felix S

    2017-06-01

    Burnout is a psychological syndrome composed of emotional exhaustion, depersonalization, and sense of lack of personal accomplishment, as a result of prolonged occupational stress. The purpose of our study was to determine the prevalence of burnout among current musculoskeletal radiology fellows and to explore causes of emotional stress. A 24-item survey was constructed on SurveyMonkey using the Maslach Burnout Inventory. We identified 82 musculoskeletal radiology fellowship programs. We recruited subjects indirectly through the program director or equivalent. Fifty-eight respondents (48 male, 10 female) identified themselves as current musculoskeletal radiology fellows and completed the survey. Comparison of the weighted subscale means in our data to the Maslach normative subscale thresholds for medical occupations indicates that musculoskeletal radiology fellows report relatively high levels of burnout with regard to lack of personal accomplishment and depersonalization, whereas emotional exhaustion levels in our sample are within the average range reported by Maslach. Although male musculoskeletal radiology fellows experience relatively high levels in two of the three dimensions of burnout (depersonalization and personal accomplishment), female musculoskeletal radiology fellows experience relatively high burnout across all three dimensions. Job market-related stress and the effort required providing care for dependents significantly affect personal accomplishment. Conversely, imbalances in the work-life relationship and feelings of powerlessness are significantly associated with depersonalization and emotional exhaustion. Musculoskeletal radiology fellows report relatively high levels of burnout. Because the consequences of burnout can be severe, early identification and appropriate intervention should be a priority. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  4. Risk communication and radiological/nuclear terrorism: a strategic view.

    PubMed

    Becker, Steven M

    2011-11-01

    It is now widely recognized that effective communication is a crucial element in radiological/nuclear terrorism preparedness. Whereas in the past, communication and information issues were sometimes viewed as secondary in comparison with technical concerns, today the need to improve risk communication, public information, and emergency messaging is seen as a high priority. The process of improving radiological/nuclear terrorism risk communication can be conceptualized as occurring in four overlapping phases. The first phase involves the recognition that communication and information issues will be pivotal in shaping how a radiological/nuclear terrorism incident unfolds and in determining its outcome. This recognition has helped shape the second phase, in which various research initiatives have been undertaken to provide an empirical basis for improved communication. In the third and most recent phase, government agencies, professional organizations and others have worked to translate research findings into better messages and informational materials. Like the first and second phases, the third phase is still unfolding. The fourth phase in risk communication for radiological/nuclear terrorism-a mature phase-is only now just beginning. Central to this phase is a developing understanding that for radiological/nuclear terrorism risk communication to be fully effective, it must go beyond crafting better messages and materials (as essential as that may be). This emerging fourth phase seeks to anchor radiological/nuclear communication in a broader approach: one that actively engages and partners with the public. In this article, each of the four stages is discussed, and future directions for improving radiological/nuclear terrorism risk communication are explored.

  5. [No exchange of information without technology : modern infrastructure in radiology].

    PubMed

    Hupperts, H; Hermann, K-G A

    2014-01-01

    Modern radiology cannot accomplish the daily numbers of examinations without supportive technology. Even though technology seems to be becoming increasingly more indispensable, business continuity should be ensured at any time and if necessary even with a limited technical infrastructure by business continuity management. An efficient information security management system forms the basis. The early radiology information systems were islands of information processing. A modern radiology department must be able to be modularly integrated into an informational network of a bigger organization. The secondary use of stored data for clinical decision-making support poses new challenges for the integrity of the data or systems because medical knowledge is displayed and provided in a context of treatment. In terms of imaging the creation and distribution radiology services work in a fully digital manner which is often different for radiology reports. Legally secure electronic diagnostic reports require a complex technical infrastructure; therefore, diagnostic findings still need to be filed as a paper document. The internal exchange and an improved dose management can be simplified by systems which continuously and automatically record the doses and thus provide the possibility of permanent analysis and reporting. Communication between patient and radiologist will gain ongoing importance. Intelligent use of technology will convey this to the radiologist and it will facilitate the understanding of the information by the patient.

  6. ICRP Publication 139: Occupational Radiological Protection in Interventional Procedures.

    PubMed

    López, P Ortiz; Dauer, L T; Loose, R; Martin, C J; Miller, D L; Vañó, E; Doruff, M; Padovani, R; Massera, G; Yoder, C

    2018-03-01

    In recent publications, such as Publications 117 and 120, the Commission provided practical advice for physicians and other healthcare personnel on measures to protect their patients and themselves during interventional procedures. These measures can only be effective if they are encompassed by a framework of radiological protection elements, and by the availability of professionals with responsibilities in radiological protection. This framework includes a radiological protection programme with a strategy for exposure monitoring, protective garments, education and training, and quality assurance of the programme implementation. Professionals with responsibilities in occupational radiological protection for interventional procedures include: medical physicists; radiological protection specialists; personnel working in dosimetry services; clinical applications support personnel from the suppliers and maintenance companies; staff engaged in training, standardisation of equipment, and procedures; staff responsible for occupational health; hospital administrators responsible for providing financial support; and professional bodies and regulators. This publication addresses these elements and these audiences, and provides advice on specific issues, such as assessment of effective dose from dosimeter readings when an apron is worn, estimation of exposure of the lens of the eye (with and without protective eyewear), extremity monitoring, selection and testing of protective garments, and auditing the interventional procedures when occupational doses are unusually high or low (the latter meaning that the dosimeter may not have been worn).

  7. Physician-directed software design: the role of utilization statistics and user input in enhancing HELP results review capabilities.

    PubMed Central

    Michael, P. A.

    1993-01-01

    The M.D. Rounds Report program was developed and implemented in June of 1992 as an adjunct to the HELP System at Rex Hospital. The program facilitates rapid access to information on allergies and current medications, laboratory results, radiology reports and therapist notes for a list of patients without physicians having to make additional menu or submenu selections. In planning for an upgrade of the program, utilization statistics and user feedback provided valuable information in terms of frequency of access, features used and unused, and the value of the program as a reporting tool in comparison to other online results reporting applications. A brief description of the functionality of the M.D. Rounds Report, evaluation of the program audit trail and user feedback, planned enhancements to the program, and a discussion of the prototyping and monitoring experience and the impact on future physician subsystem development will be presented. PMID:8130443

  8. Ex vivo investigation on the postoperative integrity of the apical constriction after the sole use of electronic working length determination.

    PubMed

    Wolgin, Michael; Grundmann, Markus J; Tchorz, Jörg P; Frank, Wilhelm; Kielbassa, Andrej M

    2017-09-01

    The present study investigated the accuracy of root canal preparation with regard to the integrity of the apical constriction (AC) using two different working length determination approaches: (1) the electronic method of working length determination (EWLD), and (2) the radiologic "gold standard" method (GS). Simulation models were constructed by arranging extracted human teeth by means of silicon bolstered gingiva masks, along with a conductive medium (alginate). Electronic working length determination (group 1; EWLD) and radiologic plus initial electronic working length determination for posterior comparability (group 2; GS) preceded manual root canal preparation of teeth in both groups. Master cones were inserted according to working lengths obtained from the group specific method. Subsequently, root apices (n=36) were longitudinally sectioned using a diamond-coated bur. The distance between the achieved apical endpoint of the endodontic preparation and the apical constriction (AC) was measured using digital photography. Then, distances between radiologically identified apical endpoints and AC (GS-AC) were compared with the corresponding distances EWLD-AC. Moreover, the postoperative status of the AC was examined with regard to both preparation approaches. Differences between distances GS-AC and EWLD-AC were not statistically significant (p >0.401) (Mann-Whitney-U). Among EWLD samples, 83% of the master cones exhibiting tugback at final insertion terminated close to the apical constriction (±0.5 mm), and no impairment of the minor diameter's integrity was observed. The sole use of EWLD allowed for a high accuracy of measurements and granted precise preparation of the apical regions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Automotive Stirling engine systems development

    NASA Technical Reports Server (NTRS)

    Richey, A. E.

    1984-01-01

    The objective of the Automotive Stirling Engine (ASE) program is to develop a Stirling engine for automotive use that provides a 30 percent improvement in fuel economy relative to a comparable internal-combustion engine while meeting emissions goals. This paper traces the engine systems' development efforts focusing on: (1) a summary of engine system performance for all Mod I engines; (2) the development, program conducted for the upgraded Mod I; and (3) vehicle systems work conducted to enhance vehicle fuel economy. Problems encountered during the upgraded Mod I test program are discussed. The importance of the EPA driving cycle cold-start penalty and the measures taken to minimize that penalty with the Mod II are also addressed.

  10. Development of an ATCA IPMI controller mezzanine board to be used in the ATCA developments for the ATLAS Liquid Argon upgrade

    NASA Astrophysics Data System (ADS)

    Dumont Dayot, Nicolas

    2012-01-01

    In the context of the LHC upgrade, we develop a new Read Out Driver (ROD) for the ATLAS Liquid Argon (LAr) community. ATCA and μTCA (Advanced/Micro Telecom Computing Architecture) is becoming a standard in high energy physics and a strong candidate to be used for boards and crates. We work to master ATCA and to integrate a large number of high speed links (96 links at 8.5 Gbps) on a ROD evaluation ATCA board. A versatile ATCA IPMI controller for ATCA boards which is FPGA Mezzanine Card (FMC) compliant has been developed to control the ROD evaluation board.

  11. Turn Basin Construction

    NASA Image and Video Library

    2017-06-14

    Modifications are underway at the Launch Complex 39 turn basin wharf at NASA's Kennedy Space Center in Florida to prepare for the arrival of the agency's massive Space Launch System (SLS) core booster aboard the barge Pegasus. Construction workers with Southeast Cherokee Construction Inc. work to shore up the turn basin area. A crane will be used to lift up precast concrete poles and position them to be driven to a depth of about 70 feet into the bedrock below the water around the turn basin. The upgrades are necessary to accommodate the 300,000-pound core booster aboard the modified Pegasus barge. The Ground Systems Development and Operations Program is overseeing the upgrades to the turn basin wharf.

  12. ML Construction Progress

    NASA Image and Video Library

    2014-12-17

    Modifications continue on the Mobile Launcher, or ML, at the Mobile Launcher Park Site at NASA’s Kennedy Space Center in Florida. Scaffolding, or work platforms, have been installed around the base of the tower on the ML to continue upgrades and modifications to the structure. The ML is being modified and strengthened to accommodate the weight, size and thrust at launch of NASA's Space Launch System, or SLS, and Orion spacecraft. The ML is one of the key elements of ground support equipment that is being upgraded by the Ground Systems Development and Operations Program at Kennedy. The ML will carry the SLS rocket and Orion spacecraft to Launch Pad 39B for its first uncrewed mission, Exploration Mission-1, in 2018.

  13. Dutch guideline for clinical foetal-neonatal and paediatric post-mortem radiology, including a review of literature.

    PubMed

    Sonnemans, L J P; Vester, M E M; Kolsteren, E E M; Erwich, J J H M; Nikkels, P G J; Kint, P A M; van Rijn, R R; Klein, W M

    2018-06-01

    Clinical post-mortem radiology is a relatively new field of expertise and not common practice in most hospitals yet. With the declining numbers of autopsies and increasing demand for quality control of clinical care, post-mortem radiology can offer a solution, or at least be complementary. A working group consisting of radiologists, pathologists and other clinical medical specialists reviewed and evaluated the literature on the diagnostic value of post-mortem conventional radiography (CR), ultrasonography, computed tomography (PMCT), magnetic resonance imaging (PMMRI), and minimally invasive autopsy (MIA). Evidence tables were built and subsequently a Dutch national evidence-based guideline for post-mortem radiology was developed. We present this evaluation of the radiological modalities in a clinical post-mortem setting, including MIA, as well as the recently published Dutch guidelines for post-mortem radiology in foetuses, neonates, and children. In general, for post-mortem radiology modalities, PMMRI is the modality of choice in foetuses, neonates, and infants, whereas PMCT is advised in older children. There is a limited role for post-mortem CR and ultrasonography. In most cases, conventional autopsy will remain the diagnostic method of choice. Based on a literature review and clinical expertise, an evidence-based guideline was developed for post-mortem radiology of foetal, neonatal, and paediatric patients. What is Known: • Post-mortem investigations serve as a quality check for the provided health care and are important for reliable epidemiological registration. • Post-mortem radiology, sometimes combined with minimally invasive techniques, is considered as an adjunct or alternative to autopsy. What is New: • We present the Dutch guidelines for post-mortem radiology in foetuses, neonates and children. • Autopsy remains the reference standard, however minimal invasive autopsy with a skeletal survey, post-mortem computed tomography, or post-mortem magnetic resonance imaging can be complementary thereof.

  14. Defense: FY2012 Budget Request, Authorization and Appropriations

    DTIC Science & Technology

    2012-02-13

    current counterinsurgency and dismounted operations in [Iraq and Afghanistan] place service women in direct combat action with the enemy. The ...vehicles, including the EFV and a modified version of the AAV-7. However, the provision bars any other amphibious vehicle development work until the ...would allow information technology companies other than the original developer to bid for maintenance and upgrade work on the system

  15. 1994 Activity Report, National Synchrotron Light Source. Annual report, October 1, 1993-September 30, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rothman, E.Z.

    1995-05-01

    This report is a summary of activities carried out at the National Synchrotron Light Source during 1994. It consists of sections which summarize the work carried out in differing scientific disciplines, meetings and workshops, operations experience of the facility, projects undertaken for upgrades, administrative reports, and collections of abstracts and publications generated from work done at the facility.

  16. Pawcatuck School.

    ERIC Educational Resources Information Center

    Randall, Kathleen

    1993-01-01

    Describes how renovation can transform a school to a state-of-the-art facility without having to work from the ground up. Examined are the planning and design phases, the outer structure upgrading, the installation of more efficient heating, ventilation, and air conditioning systems, and renovation costs. (GR)

  17. The Pegasus-Upgrade Experiment

    NASA Astrophysics Data System (ADS)

    Fonck, R. J.; Bongard, M. W.; Barr, J. L.; Frerichs, H. G.; Lewicki, B. T.; Reusch, J. A.; Schmitz, O.; Winz, G. R.

    2015-11-01

    Tokamak operation at near-unity aspect ratio provides access to advanced tokamak physics at modest parameters. High plasma current is accessible at very low toroidal field. This offers H-mode performance at Te levels that allow use of electrostatic and magnetic probe arrays through the edge pedestal region into the plasma core. An upgrade to the Pegasus ST is planned to exploit these features and pursue unique studies in three areas: local measurements of pedestal and ELM dynamics at Alfvenic timescales; direct measurement of the local plasma response to application of 3D magnetic perturbations with high spectral flexibility; and extension of Local Helicity Injection for nonsolenoidal startup to NSTX-U-relevant confinement and stability regimes. Significant but relatively low-cost upgrades to the facility are proposed: a new centerstack with larger solenoid and 2x the number of toroidal field conductors; a new TF power supply and conversion of the 200 MVA OH power supply to a cascaded multilevel inverter configuration; and installation of an extensive 3D-magnetic perturbation coil system for ELM mitigation and suppression studies. The upgraded facility will provide 0.3 MA plasmas with pulse lengths of 50-100 msec flattop, aspect ratio <1.25, and toroidal field up to 0.4 T. These research activities will be integrated into related efforts on DIII-D and NSTX-U. Work supported by US DOE grant DE-FG02-96ER54375.

  18. Results of using the NSTX-U Plasma Control System for scenario development

    NASA Astrophysics Data System (ADS)

    Boyer, M. D.; Battaglia, D. J.; Gates, D. A.; Gerhardt, S.; Menard, J.; Mueller, D.; Myers, C. E.; Ferron, J.; Sabbagh, S.; NSTX-U Team

    2016-10-01

    To best use the new capabilities of NSTX-U (e.g., higher toroidal field and additional, more distributed heating and current drive sources) and to achieve the operational goals of the program, major upgrades to the Plasma Control System have been made. These include improvements to vertical control, real-time equilibrium reconstruction, and plasma boundary shape control and the addition of flexible algorithms for beam modulation and gas injection to control the upgraded actuators in real-time, enabling their use in algorithms for stored energy and profile control. Control system commissioning activities have so far focused on vertical position and shape control. The upgraded controllers have been used to explore the vertical stability limits in inner wall limited and diverted discharges, and control of X-point and strike point locations has been demonstrated and is routinely used. A method for controlling the mid-plane inner gap, a challenge for STs, has also been added to improve reproducible control of diverted discharges. A supervisory shutdown handling algorithm has also been commissioned to ramp the plasma down and safely turn off actuators after an event such as loss of vertical control. Use of the upgrades has contributed to achieving 1MA, 0.65T scenarios with greater than 1s pulse length. Work supported by U.S. D.O.E. Contract No. DE-AC02-09CH11466.

  19. Microbial Electrolytic Capture, Separation and Regeneration of CO2 for Biogas Upgrading.

    PubMed

    Jin, Xiangdan; Zhang, Yifeng; Li, Xiaohu; Zhao, Nannan; Angelidaki, Irini

    2017-08-15

    Biogas upgrading to natural gas quality is essential for the efficient use of biogas in various applications. Carbon dioxide (CO 2 ) which constitutes a major part of the biogas is generally removed by physicochemical methods. However, most of the methods are expensive and often present environmental challenges. In this study, an innovative microbial electrolytic system was developed to capture, separate and regenerate CO 2 for biogas upgrading without external supply of chemicals, and potentially to treat wastewater. The new system was operated at varied biogas flow rates and external applied voltages. CO 2 was effectively separated from the raw biogas and the CH 4 content in the outlet reached as high as 97.0 ± 0.2% at the external voltage of 1.2 V and gas flow rate of 19.6 mL/h. Regeneration of CO 2 was also achieved in the regeneration chamber with low pH (1.34 ± 0.04). The relatively low electric energy consumption (≤0.15 kWh/m 3 biogas) along with the H 2 production which can contribute to the energy input makes the overall energy need of the system low, and thereby makes the technology promising. This work provides the first attempt for development of a sustainable biogas upgrading technology and potentially expands the application of microbial electrochemical technologies.

  20. Terminology and reporting criteria for radiofrequency ablation of tumors in the scientific literature: systematic review of compliance with reporting standards.

    PubMed

    Kang, Tae Wook; Rhim, Hyunchul; Lee, Min Woo; Kim, Young-sun; Choi, Dongil; Lim, Hyo Keun

    2014-01-01

    To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. The proposal for standardization of terminology and reporting criteria for RF tumor ablation has been gaining support according to the recently published scientific reports, especially in the field of radiology. However, more work is still needed for the complete standardization of terminology.

  1. Terminology and Reporting Criteria for Radiofrequency Ablation of Tumors in the Scientific Literature: Systematic Review of Compliance with Reporting Standards

    PubMed Central

    Kang, Tae Wook; Lee, Min Woo; Kim, Young-sun; Choi, Dongil; Lim, Hyo Keun

    2014-01-01

    Objective To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. Materials and Methods Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. Results Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. Conclusion The proposal for standardization of terminology and reporting criteria for RF tumor ablation has been gaining support according to the recently published scientific reports, especially in the field of radiology. However, more work is still needed for the complete standardization of terminology. PMID:24497798

  2. Ballistic-Failure Mechanisms in Gas Metal Arc Welds of Mil A46100 Armor-Grade Steel: A Computational Investigation

    NASA Astrophysics Data System (ADS)

    Grujicic, M.; Snipes, J. S.; Galgalikar, R.; Ramaswami, S.; Yavari, R.; Yen, C.-F.; Cheeseman, B. A.

    2014-09-01

    In our recent work, a multi-physics computational model for the conventional gas metal arc welding (GMAW) joining process was introduced. The model is of a modular type and comprises five modules, each designed to handle a specific aspect of the GMAW process, i.e.: (i) electro-dynamics of the welding-gun; (ii) radiation-/convection-controlled heat transfer from the electric-arc to the workpiece and mass transfer from the filler-metal consumable electrode to the weld; (iii) prediction of the temporal evolution and the spatial distribution of thermal and mechanical fields within the weld region during the GMAW joining process; (iv) the resulting temporal evolution and spatial distribution of the material microstructure throughout the weld region; and (v) spatial distribution of the as-welded material mechanical properties. In the present work, the GMAW process model has been upgraded with respect to its predictive capabilities regarding the spatial distribution of the mechanical properties controlling the ballistic-limit (i.e., penetration-resistance) of the weld. The model is upgraded through the introduction of the sixth module in the present work in recognition of the fact that in thick steel GMAW weldments, the overall ballistic performance of the armor may become controlled by the (often inferior) ballistic limits of its weld (fusion and heat-affected) zones. To demonstrate the utility of the upgraded GMAW process model, it is next applied to the case of butt-welding of a prototypical high-hardness armor-grade martensitic steel, MIL A46100. The model predictions concerning the spatial distribution of the material microstructure and ballistic-limit-controlling mechanical properties within the MIL A46100 butt-weld are found to be consistent with prior observations and general expectations.

  3. RADIOLOGICAL SEALED SOURCE LIBRARY: A NUCLEAR FORENSICS TOOL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Canaday, Jodi; Chamberlain, David; Finck, Martha

    If a terrorist were to obtain and possibly detonate a device that contained radiological material, radiological forensic analysis of the material and source capsule could provide law enforcement with valuable clues about the origin of the radiological material; this information could then provide further leads on where the material and sealed source was obtained, and the loss of control point. This information could potentially be utilized for attribution and prosecution. Analyses of nuclear forensic signatures for radiological materials are generally understood to include isotopic ratios, trace element concentrations, the time since irradiation or purification, and morphology. Radiological forensic signatures formore » sealed sources provide additional information that leverages information on the physical design and chemical composition of the source capsule and containers, physical markings indicative of an owner or manufacturer. Argonne National Laboratory (Argonne), in collaboration with Idaho National Laboratory (INL), has been working since 2003 to understand signatures that could be used to identify specific source manufacturers. These signatures include the materials from which the capsule is constructed, dimensions, weld details, elemental composition, and isotopic abundances of the radioactive material. These signatures have been compiled in a library known as the Argonne/INL Radiological Sealed Source Library. Data collected for the library has included open-source information from vendor catalogs and web pages; discussions with source manufacturers and touring of production facilities (both protected through non-disclosure agreements); technical publications; and government registries such as the U.S. Nuclear Regulatory Commission’s Sealed Source and Device Registry.« less

  4. 36 CFR 68.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... upgrading of mechanical, electrical and plumbing systems and other code-required work to make properties... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Definitions. 68.2 Section 68.2 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR THE...

  5. 36 CFR 68.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... upgrading of mechanical, electrical and plumbing systems and other code-required work to make properties... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Definitions. 68.2 Section 68.2 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR THE...

  6. Staying Secure for School Safety

    ERIC Educational Resources Information Center

    Youngkin, Minu

    2012-01-01

    Proper planning and preventive maintenance can increase school security and return on investment. Preventive maintenance begins with planning. Through careful planning, education institutions can determine what is working and if any equipment, hardware or software needs to be replaced or upgraded. When reviewing a school's safety and security…

  7. KSC-2014-2224

    NASA Image and Video Library

    2014-04-17

    CAPE CANAVERAL, Fla. - Inside the Vehicle Assembly Building at NASA’s Kennedy Space Center in Florida, work continues to remove the sprocket shaft assembly from the C truck of crawler-transporter 2, or CT-2. The sprocket assemblies will be placed into shipping cradles on pallets and positioned on a flatbed trailer. They will be sent to a vendor for inspections and refurbishment. Work continues in high bay 2 to upgrade CT-2. The modifications are designed to ensure CT-2’s ability to transport launch vehicles currently in development, such as the agency’s Space Launch System, to the launch pad. The Ground Systems Development and Operations Program office at Kennedy is overseeing the upgrades. For more than 45 years the crawler-transporters were used to transport the mobile launcher platform and the Apollo-Saturn V rockets and, later, space shuttles to Launch Pads 39A and B. For more information, visit: http://www.nasa.gov/exploration/systems/ground/crawler-transporter. Photo credit: NASA/Dimitri Gerondidakis

  8. KSC-2014-2214

    NASA Image and Video Library

    2014-04-17

    CAPE CANAVERAL, Fla. - Inside the Vehicle Assembly Building at NASA’s Kennedy Space Center in Florida, ground support technicians use a special work stand to guide a roller bearing shaft for insertion on the C truck of crawler-transporter 2, or CT-2. A section of the treads on the C truck were removed to allow access to the bearings. Work continues in high bay 2 to upgrade CT-2. The modifications are designed to ensure CT-2’s ability to transport launch vehicles currently in development, such as the agency’s Space Launch System, to the launch pad. The Ground Systems Development and Operations Program office at Kennedy is overseeing the upgrades. For more than 45 years the crawler-transporters were used to transport the mobile launcher platform and the Apollo-Saturn V rockets and, later, space shuttles to Launch Pads 39A and B. For more information, visit: http://www.nasa.gov/exploration/systems/ground/crawler-transporter. Photo credit: NASA/Dimitri Gerondidakis

  9. KSC-2014-2213

    NASA Image and Video Library

    2014-04-17

    CAPE CANAVERAL, Fla. - Inside the Vehicle Assembly Building at NASA’s Kennedy Space Center in Florida, ground support technicians use a special work stand to guide a roller bearing shaft for insertion on the C truck of crawler-transporter 2, or CT-2. A section of the treads on the C truck were removed to allow access to the bearings. Work continues in high bay 2 to upgrade CT-2. The modifications are designed to ensure CT-2’s ability to transport launch vehicles currently in development, such as the agency’s Space Launch System, to the launch pad. The Ground Systems Development and Operations Program office at Kennedy is overseeing the upgrades. For more than 45 years the crawler-transporters were used to transport the mobile launcher platform and the Apollo-Saturn V rockets and, later, space shuttles to Launch Pads 39A and B. For more information, visit: http://www.nasa.gov/exploration/systems/ground/crawler-transporter. Photo credit: NASA/Dimitri Gerondidakis

  10. Properties of Alfven Eigenmodes in the TAE range on the National Spherical Torus Experiment-Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2013-04-24

    A second Neutral Beam (NB) injection line is being installed on the NSTX Upgrade device, resulting in six NB sources with di erent tangency radii that will be available for heating and current drive. This work explores the properties of instabilities in the frequency range of the Toroidal Alfv en Eigenmode (TAE) for NSTX-U scenarios with various NB injection geometries, from more perpendicular to more tangential, and with increased toroidal magnetic eld with respect to previous NSTX scenarios. Predictions are based on analysis through the ideal MHD code NOVA-K. For the scenarios considered in this work, modi cations of themore » Alfv en continuum result in a frequency upshift and a broadening of the radial mode structure. The latter e ect may have consequences for fast ion transport and loss. Preliminary stability considerations indicate that TAEs are potentially unstable, with ion Landau damping representing the dominant damping mechanism« less

  11. Absorption degree analysis on biogas separation with ionic liquid systems.

    PubMed

    Zhang, Xin; Zhang, Suojiang; Bao, Di; Huang, Ying; Zhang, Xiangping

    2015-01-01

    For biogas upgrading, present work mainly focuses on either thermodynamics or mass transfer properties. A systematical study on these two aspects is important for developing a new biogas separation process. In this work, a new criterion "absorption degree", which combines both thermodynamics and mass transfer properties, was proposed for the first time to comprehensively evaluate the absorption performance. Henry's law constants of CO2 and CH4 in ionic liquids-polyethylene glycol dimethyl ethers mixtures were investigated. The liquid-side mass transfer coefficients (kL) were determined. The results indicate that IL-NHD mixtures exhibit not only a high CO2/CH4 selectivity, but also a fast kL for CO2 absorption. The [bmim][NO3]+NHD mixtures present a high absorption degree value for CO2 but a low value for CH4. For presenting a highest relative absorption degree value, the 50wt% [bmim][NO3]+50wt% NHD mixture is recommended for biogas upgrading. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Contrast and Intensity upgrades to the Texas Petawatt laser for hadron generation and non-linear QED experiments

    NASA Astrophysics Data System (ADS)

    Hegelich, Bjorn M.; Arefiev, Alexey; Ditmire, Todd; Donovan, Michael E.; Dyer, Gillis; Gaul, Erhard; Labun, Lance; Luedtke, Scott; Martinez, Mikael; McCarry, Edward; Stark, David; Pomerantz, Ishay; Tiwari, Ganesh; Toncian, Toma

    2015-11-01

    Advances in laser-based hadron generation, especially with respect to particle energy, as well as reaching the new regime of radiation dominated plasmas and non-linear QED, require laser fields of Petavolts per meter that preferably interact with very high density, overcritical plasmas. To achieve these conditions we are upgrading the Texas Petawatt Laser both respect to on-target laser intensity and laser-contrast, aiming to reach intensities of ~ 5x1022 W/cm2 and pulse contrast parameters allowing the interaction with overcritical, yet ultrathin, sub-micron targets. We will report on the planned experiments aimed at ion acceleration, neutron generation and the first experimental measurement of radiation reactions to motivate the chosen upgrade parameters. We will further report on the technical changes to the laser and present first measurements of the achieved intensity and contrast parameters. This work was supported by NNSA cooperative agreement DE-NA0002008, the Defense Advanced Research Projects Agency's PULSE program (12-63-PULSE-FP014), the Air Force Office of Scientific Research (FA9550-14-1-0045) and the National Institute of Health SBIR.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasegawa, S.

    The CMS pixel phase-1 upgrade project replaces the current pixel detector with an upgraded system with faster readout electronics during the extended year-end technical stop of 2016/2017. New electronics prototypes for the system have been developed, and tests in a realistic environment for a comprehensive evaluation are needed. A full readout test stand with either the same hardware as used in the current CMS pixel detector or the latest prototypes of upgrade electronics has been built. The setup enables the observation and investigation of a jitter increase in the data line associated with trigger rate increases. This effect is duemore » to the way in which the clock and trigger distribution is implemented in CMS. A new prototype of the electronics with a PLL based on a voltage controlled quartz crystal oscillator (QPLL), which works as jitter filter, in the clock distribution path was produced. With the test stand, it was confirmed that the jitter increase is not seen with the prototype, and also good performance was confirmed at the expected detector operation temperature ($-$20 °C).« less

  14. Energetic-environmental-economic assessment of the biogas system with three utilization pathways: Combined heat and power, biomethane and fuel cell.

    PubMed

    Wu, Bin; Zhang, Xiangping; Shang, Dawei; Bao, Di; Zhang, Suojiang; Zheng, Tao

    2016-08-01

    A typical biogas system with three utilization pathways, i.e., biogas upgrading, biogas combined heat and power (CHP), biogas solid oxide fuel cells (SOFCs) were designed. It was assessed from the viewpoint of energy, environment and economy by using energy efficiency, green degree and net present value index respectively. The assessment considered the trade-off relationships among these indexes, which is more comprehensive than previous systematic evaluation work only included single or two of the pathway(s) by using one or two of the index(es). Assessment results indicated that biogas upgrading pathway has the highest systematic energy efficiency (46.5%) and shortest payback period (8.9year) with the green degree production is the lowest (9.29gd/day). While for biogas SOFC pathway, although the green degree production is the highest (21.77gd/day), the payback period is longer (14.5year) and the energy efficiency is 13.6% lower than the biogas upgrading pathway. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Cryogenics for HL-LHC

    NASA Astrophysics Data System (ADS)

    Tavian, L.; Brodzinski, K.; Claudet, S.; Ferlin, G.; Wagner, U.; van Weelderen, R.

    The discovery of a Higgs boson at CERN in 2012 is the start of a major program of work to measure this particle's properties with the highest possible precision for testing the validity of the Standard Model and to search for further new physics at the energy frontier. The LHC is in a unique position to pursue this program. Europe's top priority is the exploitation of the full potential of the LHC, including the high-luminosity upgrade of the machine and detectors with an objective to collect ten times more data than in the initial design, by around 2030. To reach this objective, the LHC cryogenic system must be upgraded to withstand higher beam current and higher luminosity at top energy while keeping the same operation availability by improving the collimation system and the protection of electronics sensitive to radiation. This chapter will present the conceptual design of the cryogenic system upgrade with recent updates in performance requirements, the corresponding layout and architecture of the system as well as the main technical challenges which have to be met in the coming years.

  16. Assessing the water quality response to an alternative sewage disposal strategy at bathing sites on the east coast of Ireland.

    PubMed

    Bedri, Zeinab; O'Sullivan, John J; Deering, Louise A; Demeter, Katalin; Masterson, Bartholomew; Meijer, Wim G; O'Hare, Gregory

    2015-02-15

    A three-dimensional model is used to assess the bathing water quality of Bray and Killiney bathing sites in Ireland following changes to the sewage management system. The model, firstly calibrated to hydrodynamic and water quality data from the period prior to the upgrade of the Wastewater Treatment Works (WwTW), was then used to simulate Escherichia coli (E. coli) distributions for discharge scenarios of the periods prior to and following the upgrade of the WwTW under dry and wet weather conditions. E. coli distributions under dry weather conditions demonstrate that the upgrade in the WwTW has remarkably improved the bathing water quality to a Blue Flag status. The new discharge strategy is expected to drastically reduce the rainfall-related incidents in which environmental limits of the Bathing Water Directive are breached. However, exceedances to these limits may still occur under wet weather conditions at Bray bathing site due to storm overflows that may still be discharged through two sea outfalls offshore of Bray bathing site. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. The Predictive Value of Selected Extrinsic and Intrinsic Indicators of Overall Job Satisfaction in Diagnostic Radiological Technology, Radiation Therapy, and Nuclear Medicine Technology Allied Health Faculty

    ERIC Educational Resources Information Center

    Beavers, Gregory S.

    2010-01-01

    Healthcare is the largest industry in the United States and 60 percent of its 14 million workers are in allied health jobs. The need to attract and retain allied health faculty is critical to preparing a competent workforce in healthcare. This study reports the results of a survey of 259 faculty members working in diagnostic radiologic technology,…

  18. MO-AB-204-01: IHE RO Overview [Health Care

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hadley, S.

    You’ve experienced the frustration: vendor A’s device claims to work with vendor B’s device, but the practice doesn’t match the promise. Getting devices working together is the hidden art that Radiology and Radiation Oncology staff have to master. To assist with that difficult process, the Integrating the Healthcare Enterprise (IHE) effort was established in 1998, with the coordination of the Radiological Society of North America. Integrating the Healthcare Enterprise (IHE) is a consortium of healthcare professionals and industry partners focused on improving the way computer systems interconnect and exchange information. This is done by coordinating the use of published standardsmore » like DICOM and HL7. Several clinical and operational IHE domains exist in the healthcare arena, including Radiology and Radiation Oncology. The ASTRO-sponsored IHE Radiation Oncology (IHE-RO) domain focuses on radiation oncology specific information exchange. This session will explore the IHE Radiology and IHE RO process for; IHE solicitation process for new profiles. Improving the way computer systems interconnect and exchange information in the healthcare enterprise Supporting interconnectivity descriptions and proof of adherence by vendors Testing and assuring the vendor solutions to connectivity problems. Including IHE profiles in RFPs for future software and hardware purchases. Learning Objectives: Understand IHE role in improving interoperability in health care. Understand process of profile development and implantation. Understand how vendors prove adherence to IHE RO profiles. S. Hadley, ASTRO Supported Activity.« less

  19. MO-AB-204-02: IHE RAD [Health care

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seibert, J.

    You’ve experienced the frustration: vendor A’s device claims to work with vendor B’s device, but the practice doesn’t match the promise. Getting devices working together is the hidden art that Radiology and Radiation Oncology staff have to master. To assist with that difficult process, the Integrating the Healthcare Enterprise (IHE) effort was established in 1998, with the coordination of the Radiological Society of North America. Integrating the Healthcare Enterprise (IHE) is a consortium of healthcare professionals and industry partners focused on improving the way computer systems interconnect and exchange information. This is done by coordinating the use of published standardsmore » like DICOM and HL7. Several clinical and operational IHE domains exist in the healthcare arena, including Radiology and Radiation Oncology. The ASTRO-sponsored IHE Radiation Oncology (IHE-RO) domain focuses on radiation oncology specific information exchange. This session will explore the IHE Radiology and IHE RO process for; IHE solicitation process for new profiles. Improving the way computer systems interconnect and exchange information in the healthcare enterprise Supporting interconnectivity descriptions and proof of adherence by vendors Testing and assuring the vendor solutions to connectivity problems. Including IHE profiles in RFPs for future software and hardware purchases. Learning Objectives: Understand IHE role in improving interoperability in health care. Understand process of profile development and implantation. Understand how vendors prove adherence to IHE RO profiles. S. Hadley, ASTRO Supported Activity.« less

  20. MO-AB-204-04: Connectathons and Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosch, W.

    You’ve experienced the frustration: vendor A’s device claims to work with vendor B’s device, but the practice doesn’t match the promise. Getting devices working together is the hidden art that Radiology and Radiation Oncology staff have to master. To assist with that difficult process, the Integrating the Healthcare Enterprise (IHE) effort was established in 1998, with the coordination of the Radiological Society of North America. Integrating the Healthcare Enterprise (IHE) is a consortium of healthcare professionals and industry partners focused on improving the way computer systems interconnect and exchange information. This is done by coordinating the use of published standardsmore » like DICOM and HL7. Several clinical and operational IHE domains exist in the healthcare arena, including Radiology and Radiation Oncology. The ASTRO-sponsored IHE Radiation Oncology (IHE-RO) domain focuses on radiation oncology specific information exchange. This session will explore the IHE Radiology and IHE RO process for; IHE solicitation process for new profiles. Improving the way computer systems interconnect and exchange information in the healthcare enterprise Supporting interconnectivity descriptions and proof of adherence by vendors Testing and assuring the vendor solutions to connectivity problems. Including IHE profiles in RFPs for future software and hardware purchases. Learning Objectives: Understand IHE role in improving interoperability in health care. Understand process of profile development and implantation. Understand how vendors prove adherence to IHE RO profiles. S. Hadley, ASTRO Supported Activity.« less

  1. MO-AB-204-03: Profile Development and IHE Process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pauer, C.

    You’ve experienced the frustration: vendor A’s device claims to work with vendor B’s device, but the practice doesn’t match the promise. Getting devices working together is the hidden art that Radiology and Radiation Oncology staff have to master. To assist with that difficult process, the Integrating the Healthcare Enterprise (IHE) effort was established in 1998, with the coordination of the Radiological Society of North America. Integrating the Healthcare Enterprise (IHE) is a consortium of healthcare professionals and industry partners focused on improving the way computer systems interconnect and exchange information. This is done by coordinating the use of published standardsmore » like DICOM and HL7. Several clinical and operational IHE domains exist in the healthcare arena, including Radiology and Radiation Oncology. The ASTRO-sponsored IHE Radiation Oncology (IHE-RO) domain focuses on radiation oncology specific information exchange. This session will explore the IHE Radiology and IHE RO process for; IHE solicitation process for new profiles. Improving the way computer systems interconnect and exchange information in the healthcare enterprise Supporting interconnectivity descriptions and proof of adherence by vendors Testing and assuring the vendor solutions to connectivity problems. Including IHE profiles in RFPs for future software and hardware purchases. Learning Objectives: Understand IHE role in improving interoperability in health care. Understand process of profile development and implantation. Understand how vendors prove adherence to IHE RO profiles. S. Hadley, ASTRO Supported Activity.« less

  2. Information management of a department of diagnostic imaging.

    PubMed

    Vincenzoni, M; Campioni, P; Vecchioli Scaldazza, A; Capocasa, G; Marano, P

    1998-01-01

    It is well-known that while RIS allows the management of all input and output data of a Radiology service, PACS plays a major role in the management of all radiologic images. However, the two systems should be closely integrated: scheduling of a radiologic exam requires direct automated integration with the system of image management for retrieval of previous exams and storage of the exam just completed. A modern information system of integration of data and radiologic images should be based on an automated work flow management in al its components, being at the same time flexible and compatible with the ward organization to support and computerize each stage of the working process. Similarly, standard protocols (DICOM 3.0, HL7) defined for interfacing with the Diagnostic Imaging (D.I.) department and the other components of modules of a modern HIS, should be used. They ensure the system to be expandable and accessible to ensure share and integration of information with HIS, emergency service or wards. Correct RIS/PACS integration allows a marked improvement in the efficiency of a modern D.I. department with a positive impact on the daily activity, prompt availability of previous data and images with sophisticated handling of diagnostic images to enhance the reporting quality. The increased diffusion of internet and intranet technology predicts future developments still to be discovered.

  3. Summary of the Italian inter-society recommendations for radiation protection optimization in interventional radiology.

    PubMed

    Compagnone, Gaetano; Padovani, Renato; D'Avanzo, Maria Antonietta; Grande, Sveva; Campanella, Francesco; Rosi, Antonella

    2018-05-01

    A Working Group coordinated by the Italian National Institute of Health (Istituto Superiore di Sanità) and the National Workers Compensation Authority (Istituto Nazionale per l'Assicurazione contro gli Infortuni sul Lavoro, INAIL) and consisting of 11 Italian scientific/professional societies involved in the fluoroscopically guided interventional practices has been established to define recommendations for the optimization of patients and staff radiation protection in interventional radiology. A summary of these recommendations is here reported. A multidisciplinary approach was used to establish the Working Group by involving radiologists, interventional radiologists, neuroradiologists, interventional cardiologists, occupational health specialists, medical physicists, radiation protection experts, radiographers and nurses. The Group operated as a "Consensus Conference". Three main topics have been addressed: patient radiation protection (summarized in ten "golden rules"); staff radiation protection (summarized in ten "golden rules"); and education/training of interventional radiology professionals. In the "golden rules", practical and operational recommendations were provided to help the professionals in optimizing dose delivered to patients and reducing their own exposure. Operative indications dealt also with continuing education and training, and recommendations on professional accreditation and certification. The "Consensus Conference" was the methodology adopted for the development of these recommendations. Involvement of all professionals is a winning approach to improve practical implementation of the recommendations, thus getting a real impact on the optimization of the interventional radiology practices.

  4. Slum upgrading strategies involving physical environment and infrastructure interventions and their effects on health and socio-economic outcomes.

    PubMed

    Turley, Ruth; Saith, Ruhi; Bhan, Nandita; Rehfuess, Eva; Carter, Ben

    2013-01-31

    Slums are densely populated, neglected parts of cities where housing and living conditions are exceptionally poor. In situ slum upgrading, at its basic level, involves improving the physical environment of the existing area, such as improving and installing basic infrastructure like water, sanitation, solid waste collection, electricity, storm water drainage, access roads and footpaths, and street lighting, as well as home improvements and securing land tenure. To explore the effects of slum upgrading strategies involving physical environment and infrastructure interventions on the health, quality of life and socio-economic wellbeing of urban slum dwellers in low and middle income countries (LMIC). Where reported, data were collected on the perspectives of slum dwellers regarding their needs, preferences for and satisfaction with interventions received. We searched for published and unpublished studies in 28 bibliographic databases including multidisciplinary (for example Scopus) and specialist databases covering health, social science, urban planning, environment and LMIC topics. Snowballing techniques included searching websites, journal handsearching, contacting authors and reference list checking. Searches were not restricted by language or publication date. We included studies examining the impact of slum upgrading strategies involving physical environment or infrastructure improvements (with or without additional co-interventions) on the health, quality of life and socio-economic wellbeing of LMIC urban slum dwellers. Randomised controlled trials (RCTs), controlled before and after studies (CBAs) and interrupted time series (ITS) were eligible for the main analysis. Controlled studies with only post-intervention data (CPI) and uncontrolled before and after (UBA) studies were included in a separate narrative to examine consistency of results and to supplement evidence gaps in the main analysis. Two authors independently extracted data and assessed risk of bias for each study. Differences between the included study interventions and outcomes precluded meta-analysis so the results were presented in a narrative summary with illustrative harvest plots. The body of evidence for outcomes within the main analysis was assessed according to GRADE as very low, low, moderate or high quality. We identified 10,488 unique records, with 323 screened as full text. Five studies were included for the main analysis: one RCT with a low risk, two CBAs with a moderate risk and two CBAs with a high risk of bias. Three CBAs evaluated multicomponent slum upgrading strategies. Road paving only was evaluated in one RCT and water supply in one CBA. A total of 3453 households or observations were included within the four studies reporting sample sizes.Most health outcomes in the main studies related to communicable diseases, for which the body of evidence was judged to be low quality. One CBA with a moderate risk of bias found that diarrhoeal incidence was reduced in households which received water connections from a private water company (risk ratio (RR) 0.53; 95% confidence interval (CI) 0.27 to 1.04) and the severity of diarrhoeal episodes (RR 0.48; 95% CI 0.19 to 1.22). There was no effect for duration of diarrhoea. Road paving did not result in changes in parasitic infections or sickness in one RCT. After multicomponent slum upgrading, claims for a waterborne disease as opposed to a non-waterborne disease reduced (RR 0.64; 95% CI 0.27 to 0.98) in one CBA with a high risk of bias but there was no change in sanitation-related mortality in a CBA with a moderate risk of bias.The majority of socio-economic outcomes reported within the main studies related to financial poverty, for which the body of evidence was of very low quality. Results were mixed amongst the main studies; one RCT and two CBAs reported no effect on the income of slum dwellers following slum upgrading. One further CBA found significant reduction in monthly water expenditure (mean difference (MD) -17.11 pesos; 95% CI -32.6 to -1.62). One RCT also showed mixed results for employment variables, finding no effect on unemployment levels but increased weekly worked hours (MD 4.68; 95% CI -0.46 to 9.82) and lower risk of residents intending to migrate for work (RR 0.78; 95% CI 0.60 to 1.01).There was no evidence available to assess the impact of slum upgrading on non-communicable diseases or social capital. Maternal and perinatal conditions, infant mortality, nutritional deficiencies, injuries, self-reported quality of life, education and crime were evaluated in one study each.Nine supporting studies were included that measured varying outcomes (6794 households or observations within eight studies reporting sample sizes). One CPI evaluated cement flooring only while three UBAs and five CPIs evaluated multicomponent slum upgrading strategies. All studies but one had a high risk of bias.The studies reinforced main study findings for diarrhoea incidence and water-related expenditure. Findings for parasitic infections and financial poverty were inconsistent with the main studies. In addition, supporting studies reported a number of disparate outcomes that were not evaluated in the main studies.Five supporting studies included some limited information on slum dweller perspectives. They indicated the importance of appropriate siting of facilities, preference for private facilities, delivering synergistic interventions together, and ensuring that infrastructure was fit for purpose and systems were provided for cleaning, maintenance and repair. A high risk of bias within the included studies, heterogeneity and evidence gaps prevent firm conclusions on the effect of slum upgrading strategies on health and socio-economic wellbeing. The most common health and socio-economic outcomes reported were communicable diseases and indicators of financial poverty. There was a limited but consistent body of evidence to suggest that slum upgrading may reduce the incidence of diarrhoeal diseases and water-related expenditure. The information available on slum dwellers' perspectives provided some insight to barriers and facilitators for successful implementation and maintenance of interventions.The availability and use of reliable, comparable outcome measures to determine the effect of slum upgrading on health, quality of life and socio-economic wellbeing would make a useful contribution to new research in this important area. Given the complexity in delivering slum upgrading, evaluations should look to incorporate process and qualitative information alongside quantitative effectiveness data to determine which particular interventions work (or don't work) and for whom.

  5. The top 100 articles in the radiology of trauma: a bibliometric analysis.

    PubMed

    Dolan, Ryan Scott; Hanna, Tarek N; Warraich, Gohar Javed; Johnson, Jamlik-Omari; Khosa, Faisal

    2015-12-01

    The purpose of this study was to identify the 100 top-cited articles in the radiology of trauma, analyze the resulting database to understand factors resulting in highly cited works, and establish trends in trauma imaging. An initial database was created via a Web of Science (WOS) search of all scientific journals using the search terms "trauma" and either "radiology" or a diagnostic modality. Articles were ranked by citation count and screened by two attending radiologists plus a tiebreaker for appropriateness. The following information was collected from each article: WOS all database citations, year, journal, authors, department affiliation, study type and design, sample size, imaging modality, subspecialty, organ, and topic. Citations for the top 100 articles ranged from 82-252, and citations per year ranged from 2.6-37.2. A plurality of articles were published in the 1990s (n = 45) and 1980s (n = 31). Articles were published across 24 journals, most commonly Radiology (n = 31) and Journal of Trauma-Injury, Infection, and Critical Care (n = 28). Articles had an average of five authors and 35 % of first authors were affiliated with a department other than radiology. Forty-six articles had sample sizes of 100 or fewer. Computed tomography (CT) was the most common modality (n = 67), followed by magnetic resonance (MR; n = 22), and X-ray (XR; n = 11). Neuroradiology (n = 48) and abdominal radiology (n = 36) were the most common subspecialties. The 100 top-cited articles in the radiology of trauma are diverse. Subspecialty bibliometric analyses identify the most influential articles of a particular field, providing more implications to clinical radiologists, trainees, researchers, editors, and reviewers than radiology-wide lists.

  6. Radiology Reporting System Data Exchange With the Electronic Health Record System: A Case Study in Iran.

    PubMed

    Ahmadi, Maryam; Ghazisaeidi, Marjan; Bashiri, Azadeh

    2015-03-18

    In order to better designing of electronic health record system in Iran, integration of health information systems based on a common language must be done to interpret and exchange this information with this system is required. This study provides a conceptual model of radiology reporting system using unified modeling language. The proposed model can solve the problem of integration this information system with the electronic health record system. By using this model and design its service based, easily connect to electronic health record in Iran and facilitate transfer radiology report data. This is a cross-sectional study that was conducted in 2013. The study population was 22 experts that working at the Imaging Center in Imam Khomeini Hospital in Tehran and the sample was accorded with the community. Research tool was a questionnaire that prepared by the researcher to determine the information requirements. Content validity and test-retest method was used to measure validity and reliability of questioner respectively. Data analyzed with average index, using SPSS. Also Visual Paradigm software was used to design a conceptual model. Based on the requirements assessment of experts and related texts, administrative, demographic and clinical data and radiological examination results and if the anesthesia procedure performed, anesthesia data suggested as minimum data set for radiology report and based it class diagram designed. Also by identifying radiology reporting system process, use case was drawn. According to the application of radiology reports in electronic health record system for diagnosing and managing of clinical problem of the patient, with providing the conceptual Model for radiology reporting system; in order to systematically design it, the problem of data sharing between these systems and electronic health records system would eliminate.

  7. Fuzzy risk analysis of a modern γ-ray industrial irradiator.

    PubMed

    Castiglia, F; Giardina, M

    2011-06-01

    Fuzzy fault tree analyses were used to investigate accident scenarios that involve radiological exposure to operators working in industrial γ-ray irradiation facilities. The HEART method, a first generation human reliability analysis method, was used to evaluate the probability of adverse human error in these analyses. This technique was modified on the basis of fuzzy set theory to more directly take into account the uncertainties in the error-promoting factors on which the methodology is based. Moreover, with regard to some identified accident scenarios, fuzzy radiological exposure risk, expressed in terms of potential annual death, was evaluated. The calculated fuzzy risks for the examined plant were determined to be well below the reference risk suggested by International Commission on Radiological Protection.

  8. User and Performance Impacts from Franklin Upgrades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Yun

    2009-05-10

    The NERSC flagship computer Cray XT4 system"Franklin" has gone through three major upgrades: quad core upgrade, CLE 2.1 upgrade, and IO upgrade, during the past year. In this paper, we will discuss the various aspects of the user impacts such as user access, user environment, and user issues etc from these upgrades. The performance impacts on the kernel benchmarks and selected application benchmarks will also be presented.

  9. [Telecommunications, health and radiology: potential synergies for the new millennium].

    PubMed

    Lagalla, R

    2001-01-01

    Healthcare telematics, or telemedicine, is a new methodology that applies the potentialities of telecommunications technologies to the needs of medicine, thereby greatly contributing to improving the management of clinical data and medical information for the benefit of the individual patient and the community at large. The fields of application of Telemedicine are becoming increasingly vast, and this gives rise to technical problems (interconnections) as well as professional, ethical, medico-legal and legal problems. The dissemination of Telemedicine will require changes to be made to the organisation and delivery of the medical/administrative services connected to the management of patient data, the remote provision of care, and the impact of Telemedicine itself (e.g. need to standardise the nomenclature for telemedicine services). In addition, it will also call for a careful analysis of costs and benefits for both healthcare providers and patients. One of the most interesting experiences in terms of impact is Teleradiology. This is neither a new discipline nor a (sub)specialty: the practice of Teleradiology must comply with the rules regulating any radiological medical act, the primary aim of which is to contribute to establishing - rapidly and accurately - a diagnosis that will affect treatment strategies. It may be anticipated that in some situations Teleradiology will significantly change the working practices of Radiology Specialists and Radiology Technicians. Because it is better to anticipate problems rather than wait for them to arise, our Scientific Society, which is always sensitive to emerging issues, intends to propose the following recommendations/guidelines for the use of Teleradiology in the common interest of the community and healthcare workers. The invitation to take part in the initiative proposed by the Italian Society of Medical Radiology (SIRM), the Italian Association of Nuclear Medicine (AIMN) and the Italian Association of Neuroradiology (AINR) was received with great satisfaction and is proof that we are working towards common goals. As on other occasions, this was reflected in the excellent collaboration between the National Radiologists' Union (SNR), the Italian Association of Medical Physics (AIFM) and the National Federation of Radiology Technicians (F.N.C.TSRM) in drafting the document. The document aims to highlight the potentialities and limitations in the use of Teleradiology and to provide a set of recommendations/guidelines, which are not, however, to be intended as strict, absolute rules. Because this field is continually evolving both in structural and regulatory terms, and because it is very difficult to establish universal criteria to rigidly define behavioural models for implementing and managing Teleradiology-related activities (which in any case fall into the category of radiological medical acts), the recommendations/guidelines proposed necessarily have an informative rather than prescriptive nature. The document starts by defining the meaning of the following currently used terms: Teleconsultation; Telediagnosis; Teledidactics. It then goes on to analyse the following aspects of Teleradiology: Technological requirements; Qualifications and training of Medical Personnel; Qualifications, training and competences of Radiology Technicians. Based on the regulations in force in Italy, these recommendations are structured in terms of rationale and possible professional issues arising from the use of Teleradiology. A section is devoted to data security and confidentiality, including legal implications, an area which is currently evolving and being studied in Italy and abroad. Finally, the professional liabilities of all the healthcare providers involved in Teleradiology (imprudence, incompetence, negligence) are outlined, as well as the responsibilities related to the necessary maintenance of equipment. The aim of the document is to propose recommendations/guidelines for the correct use and validation of Teleradiology. The Scientific Societies SIRM-AIMN-AINR and the Academic Institutions, together with the SNR, AIFM and the F.N.C.TSRM, the Regional Bodies and the Italian National Health Trusts are required to make a positive and constructive commitment to this new field, which has become the object of considerable attention and interests. While confirming that, if used correctly, this methodology will no doubt increase the overall efficiency of Diagnostic Imaging - in the primary interest of the patient's right to health - it is felt that attention should also be paid to the working practices of the Radiology Specialists and Radiology Technicians and to the training of both. It is necessary to standardise training and practice, and to make an integrated and coherent use of resources with respect to the healthcare goals we wish to attain. Many have described the undisputed advantages of Teleradiology, but there have been relatively few reports on the related risks and recommendations for its use. It is certain that an improper use of the method (forced& interpretation of the bill on complementary diagnostic activities, operational misunderstandings between Radiology Specialists and Radiology Technicians, rarefaction of the relationship between Radiologist and Patient, obligation to use teleconsultation in all situations) will lead to considerable disadvantages for all those working in the field of Radiology, specialists and radiology technicians alike. Therefore, by adopting this document, which is by no means against Teleradiology but for a rational use of the method and full awareness of what it actually implies, the Scientific Society intends on the one hand to participate actively and concretely in the process of regulating all those aspects of Teleradiology for which it is competent - rather than waiting for regulations to be imposed from above - and, on the other, to provide, through its highly qualified Study Group (Specialists in Radiology, Nuclear Medicine, Legal Medicine, Medical Physics, and Radiology Technicians), Radiologists, Specialists in Nuclear Medicine, Neuroradiologists and Radiology Technicians with practical recommendations for use/guidelines for the correct and rational performance of their (tele)radiological acts. These indications and recommendations are also being submitted to the Italian Government. Teleradiology has attracted so much attention that, even as a result of pressure from Industry, an international consensus conference is needed to regulate the rational and informed use of this new methodology.

  10. UTILIZATION OF MOBILE FACILITIES FOR DEVELOPMENT OF ENTRY WORK SKILLS FOR ARKANSAS' RURAL UNEMPLOYED AND LOW INCOME EARNERS, A FEASIBILITY STUDY.

    ERIC Educational Resources Information Center

    Nevada Univ., Reno. School Planning Lab.

    THE FEASIBILITY AND METHODS OF USING MOBILE FACILITIES IN UPGRADING THE WORK SKILLS OF RURAL LOW INCOME WAGE EARNERS ARE EXPLORED. SUCH MOBILE FACILITIES WOULD BE DIRECTED TOWARD 3 SPECIFIC GROUPS OF PEOPLE--SMALL ACREAGE FARMERS WHO PRODUCED ONLY A MINIMAL INCOME, THE RURAL LOW-INCOME NEGRO POPULATION, AND YOUNG RURAL SCHOOL DROPOUTS WITH LITTLE…

  11. Honorary authorship in radiologic research articles: assessment of frequency and associated factors.

    PubMed

    Eisenberg, Ronald L; Ngo, Long; Boiselle, Philip M; Bankier, Alexander A

    2011-05-01

    To quantify the frequency of perceived honorary authorship in radiologic journals and to identify specific factors that increase its prevalence. This study qualified for exempt status by the institutional review board. An electronic survey was sent to first authors of all original research articles published in Radiology and European Radiology over 3 years. Questions included guidelines used for determining authorship, contributions of coauthors, the perception of honorary authorship, and demographic information. Univariable analysis of sample proportions was performed by using χ(2) tests. Multivariable logistic regression models were used to assess the independent factors that were associated with the probability of perceiving honorary authorship. Of the 392 (29.3%) of 1338 first authors who responded to the survey, 102 (26.0%) perceived that one or more coauthors did not make sufficient contributions to merit being included as an author. Of the 392 respondents, 231 (58.9%) stated that one or more coauthors performed only "nonauthor" tasks according to International Committee of Medical Journal Editors criteria. Factors associated with an increased first-author perception of honorary authorship included lower academic rank (adjusted odds ratio [OR]: 2.89; 95% confidence interval [CI]: 1.66, 5.06), as well as working in an environment in which the section or department head was automatically listed as an author (adjusted OR: 3.80; 95% CI: 2.13, 6.79). The percentage of honorary authorship was significantly higher (P = .019) among respondents who did not follow journal requirements for authorship. The rate of perceived honorary authorship (overall, 26.0%) was substantially more frequent among respondents of lower academic rank and in those working in an environment in which their section or department head was automatically listed as an author. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101500/-/DC1. RSNA, 2011

  12. Cutting costs: the impact of price lists on the cost development at the emergency department.

    PubMed

    Schilling, Ulf Martin

    2010-12-01

    It was shown that physicians working at the Swedish emergency department (ED) are unaware of the costs for investigations performed. This study evaluated the possible impact of price lists on the overall laboratory and radiology costs at the ED of a Swedish university hospital. Price lists including the most common laboratory analyses and radiological investigations at the ED were created. The lists were distributed to all internal medicine physicians by e-mail and exposed above their working stations continually. No lists were provided for the orthopaedic control group. The average costs for laboratory and radiological investigations during the months of June and July 2007 and 2008 were calculated. Neither clinical nor admission procedures were changed. The physicians were blinded towards the study. Statistical analysis was performed using the Student's t-test. A total of 1442 orthopaedic and 1585 medical patients were attended to in 2007. In 2008, 1467 orthopaedic and 1637 medical patients required emergency service. The average costs per patient were 980.27 SKR (98€)/999.41 SKR (100€, +1.95%) for orthopaedic and 1081.36 SKR (108€)/877.3 SKR (88€, -18.8%) for medical patients. Laboratory costs decreased by 9% in orthopaedic and 21.4% in medical patients. Radiology costs changed +5.4% in orthopaedic and -20.59% in medical patients. The distribution and promotion of price lists as a tool at the ED to heighten cost awareness resulted in a major decrease in the investigation costs. A significant decrease in radiological costs could be observed. It can be concluded that price lists are an effective tool to cut costs in public healthcare.

  13. A Platform for Innovation and Standards Evaluation: a Case Study from the OpenMRS Open-Source Radiology Information System.

    PubMed

    Gichoya, Judy W; Kohli, Marc; Ivange, Larry; Schmidt, Teri S; Purkayastha, Saptarshi

    2018-05-10

    Open-source development can provide a platform for innovation by seeking feedback from community members as well as providing tools and infrastructure to test new standards. Vendors of proprietary systems may delay adoption of new standards until there are sufficient incentives such as legal mandates or financial incentives to encourage/mandate adoption. Moreover, open-source systems in healthcare have been widely adopted in low- and middle-income countries and can be used to bridge gaps that exist in global health radiology. Since 2011, the authors, along with a community of open-source contributors, have worked on developing an open-source radiology information system (RIS) across two communities-OpenMRS and LibreHealth. The main purpose of the RIS is to implement core radiology workflows, on which others can build and test new radiology standards. This work has resulted in three major releases of the system, with current architectural changes driven by changing technology, development of new standards in health and imaging informatics, and changing user needs. At their core, both these communities are focused on building general-purpose EHR systems, but based on user contributions from the fringes, we have been able to create an innovative system that has been used by hospitals and clinics in four different countries. We provide an overview of the history of the LibreHealth RIS, the architecture of the system, overview of standards integration, describe challenges of developing an open-source product, and future directions. Our goal is to attract more participation and involvement to further develop the LibreHealth RIS into an Enterprise Imaging System that can be used in other clinical imaging including pathology and dermatology.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Del Bianco, M.; Wiehagen, J.

    This project evaluated the effectiveness and affordability of integrating retrofit insulated panels into a re-siding project. The Partnership for Home Innovation (PHI) teamed with New York State Energy Research and Development Authority (NYSERDA), the Albany Housing Authority (AHA), and the New York State Weatherization Assistance Program (WAP) administered by Albany Community Action Partnership to demonstrate an energy retrofit and siding upgrade on a two-story, seven unit, multifamily building in Albany New York (CZ 5). The project focused on accomplishing three goals - doubling the existing wall thermal resistance (from approximately R-13 to a weighted average of R-27), reduction of buildingmore » air leakage, and completion of the retrofit within a budget where the additional cost for upgrading wall's thermal resistance is equal to the cost of the standard re-siding effort (i.e., the total cost of the energy efficient re-siding scope of work is not more than double the cost of the standard re-siding effort). Lessons learned from the project strongly indicate that the retrofit panel technology can be installed using common installation practices and with minimal training. Other lessons learned include limitation on the use of standard air sealing materials during cold weather installations and the need to develop better installation guidance for trades working with the level of tolerances that may be present in the existing structure. This technology demonstration showed that exterior retrofit panels provide a viable and reasonable option for the siding trades to increase market opportunities and achieve synergistic benefits for aesthetic upgrades to a building's exterior.« less

  15. Robonaut 2 on the International Space Station: Status Update and Preparations for IVA Mobility

    NASA Technical Reports Server (NTRS)

    Ahlstrom, Thomas D.; Diftler, Myron E.; Berka, Reginald B.; Badger, Julia M.; Yayathi, Sandeep; Curtis, Andrew W.; Joyce, Charles A.

    2013-01-01

    Robotics engineers, ground controllers and International Space Station (ISS) crew have been running successful experiments using Robonaut 2 (R2) on-board the ISS for more than a year. This humanoid upper body robot continues to expand its list of achievements and its capabilities to safely demonstrate maintenance and servicing tasks while working alongside human crewmembers. The next phase of the ISS R2 project will transition from a stationary Intra Vehicular Activity (IVA) upper body using a power/data umbilical, to an IVA mobile system with legs for repositioning, a battery backpack power supply, and wireless communications. These upgrades will enable the R2 team to evaluate hardware performance and to develop additional control algorithms and control verification techniques with R2 inside the ISS in preparation for the Extra Vehicular Activity (EVA) phase of R2 operations. As R2 becomes more capable in assisting with maintenance tasks, with minimal supervision, including repositioning itself to different work sites, the ISS crew will be burdened with fewer maintenance chores, leaving them more time to conduct other activities. R2's developers at the Johnson Space Center (JSC) are preparing the R2 IVA mobility hardware and software upgrades for delivery to the ISS in late 2013. This paper summarizes R2 ISS achievements to date, briefly describes the R2 IVA mobility upgrades, and discusses the R2 IVA mobility objectives and plans.

  16. Practical solutions for staff recruitment & retention.

    PubMed

    Vander Hoek, N

    2001-01-01

    There are three essential topics for radiology managers to consider in light of persistent staffing shortages: support of the profession and educational programs, perks as recruitment tools and incentives as retention tools. Some activities that can help support departments and educational programs for radiologic technologists are job shadowing, training for volunteer services, advanced placement for school applicants, sponsoring an educational program or clinical training site, creating a positive work environment and supporting outreach projects geared to local high schools. Traditional perks used in recruitment efforts have included relocation assistance, travel and lodging expenses during the interview process, loan repayment, scholarships and sign-on bonuses. Some common incentives for retaining employees are tuition reimbursement, cross training, availability of educational resources, continuing education opportunities, professional development and incremental increases in salary. There are many other tools that can be used, such as career ladders, creating an environment conducive to teamwork or a more personal atmosphere and showcasing talents of various staff members. There is much overlap among these suggestions in support of the profession and educational programs, recruitment and retention of qualified staff radiologic technologists. Radiology managers can and should be creative in developing different programs to build loyalty and commitment to a radiology department.

  17. Analyzing the glass ceiling effect among radiologic technologists.

    PubMed

    Belinsky, Susan B; Blagg, James D

    2011-01-01

    The literature has suggested that advancement within politics, academia and the health professions is influenced by gender. Purpose The authors conducted a survey to determine whether advancement was equal by gender in the radiologic science disciplines of nuclear medicine technology, radiation therapy and radiography. The survey was mailed to 900 subjects, 300 from each discipline. The discipline groups were further stratified by initial year of American Registry of Radiologic Technology certification; the authors selected 100 subjects from each discipline who initially were certified in 1978, 100 in 1988 and 100 in 1998. Approximately 33% of those selected responded. The findings of the study provided no evidence that men are promoted differentially than women. Women perceived that men were paid more for the same work. It appears that gender bias is pervasive outside of promotion decisions and, indeed, that some illegal actions (eg, sexual harassment, inappropriate gender-related interview questions) take place in radiologic science clinical settings. It is hoped that this study will set a baseline for future research on whether there is a glass ceiling effect in radiologic clinical practice and stimulate discussion of the importance of equal opportunity regardless of gender.

  18. Characterizing Hospital Workers' Willingness to Respond to a Radiological Event

    PubMed Central

    Balicer, Ran D.; Catlett, Christina L.; Barnett, Daniel J.; Thompson, Carol B.; Hsu, Edbert B.; Morton, Melinda J.; Semon, Natalie L.; Watson, Christopher M.; Gwon, Howard S.; Links, Jonathan M.

    2011-01-01

    Introduction Terrorist use of a radiological dispersal device (RDD, or “dirty bomb”), which combines a conventional explosive device with radiological materials, is among the National Planning Scenarios of the United States government. Understanding employee willingness to respond is critical for planning experts. Previous research has demonstrated that perception of threat and efficacy is key in the assessing willingness to respond to a RDD event. Methods An anonymous online survey was used to evaluate the willingness of hospital employees to respond to a RDD event. Agreement with a series of belief statements was assessed, following a methodology validated in previous work. The survey was available online to all 18,612 employees of the Johns Hopkins Hospital from January to March 2009. Results Surveys were completed by 3426 employees (18.4%), whose demographic distribution was similar to overall hospital staff. 39% of hospital workers were not willing to respond to a RDD scenario if asked but not required to do so. Only 11% more were willing if required. Workers who were hesitant to agree to work additional hours when required were 20 times less likely to report during a RDD emergency. Respondents who perceived their peers as likely to report to work in a RDD emergency were 17 times more likely to respond during a RDD event if asked. Only 27.9% of the hospital employees with a perception of low efficacy declared willingness to respond to a severe RDD event. Perception of threat had little impact on willingness to respond among hospital workers. Conclusions Radiological scenarios such as RDDs are among the most dreaded emergency events yet studied. Several attitudinal indicators can help to identify hospital employees unlikely to respond. These risk-perception modifiers must then be addressed through training to enable effective hospital response to a RDD event. PMID:22046238

  19. Upgrading in an Industrial Setting. Final Report.

    ERIC Educational Resources Information Center

    Russell, Wendell

    The project objectives were: (1) to assess existing industrial upgrading practices in an Atomic Energy Commission contractor organization, (2) to design new alternative upgrading methods, (3) to experiment with new upgrading methods, (4) to plan for utilization of proven upgrading programs, and (5) to document and disseminate activities. A twelve…

  20. Extending DICOM imaging to new clinical specialties in the healthcare enterprise

    NASA Astrophysics Data System (ADS)

    Kuzmak, Peter M.; Dayhoff, Ruth E.

    2002-05-01

    DICOM is a success for radiology and cardiology and it is now starting to be used for the other clinical specialties. The US Department of Veterans Affairs has been instrumental in promoting this advancement. We have worked with a number of non-radiology clinical speciality imaging vendors over the past two years, encouraging them to support DICOM, providing requirement specifications. Validating their implementations, using their products, and integrating their systems with the VA healthcare enterprise. We require each new clinical speciality vendor to support the DICOM Modality Worklist and Storage services and insist that they perform validation testing with us over the Internet. Two years ago we began working with two commercial DICOM image acquisition applications in ophthalmology and endoscopy. We are now dealing with over a dozen: five in ophthalmology, two in endoscopy, and six in dental. This has been a very productive endeavor. Because mature software development toolkits now exist, the vendors can quickly integrate DICOM with their existing imaging products. Each of the dental vendors, for example, was able to accomplish this task in less than three months. Getting the imaging modality vendors to support DICOM is only part of the story, however. We are also working on getting the VistA hospital information system to properly handle DICOM interfaces to various clinical specialties. This has been more difficult than expected because the workflow in clinical specialties is much more varied than that in radiology. This required us to develop software that is much more flexible than that used for radiology. Fortunately, the standard DICOM Modality Worklist and Storage services can be used without change. In addition to a more variable workflow, the use of structured reporting is much more advanced in clinical specialties than in radiology, and significant work is needed to define templates and communicate this data using DICOM. Since some speciality modules of our hospital information system currently store only report text, we also have to figure out how to store and display the discrete structured report data. The work involved in extending DICOM to the clinical specialties, and in integrating them with the hospital information system is an ongoing and worthwhile challenge. Our goal is to incorporate al of the patient's data into the electronic record, and DICOM is making this easier for everyone. Considerable investment, however, has to be made in the hospital information system software to accrue the full benefit.

  1. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.

  2. Enterprise-wide PACS: beyond radiology, an architecture to manage all medical images.

    PubMed

    Bandon, David; Lovis, Christian; Geissbühler, Antoine; Vallée, Jean-Paul

    2005-08-01

    Picture archiving and communication systems (PACS) have the vocation to manage all medical images acquired within the hospital. To address the various situations encountered in the imaging specialties, the traditional architecture used for the radiology department has to evolve. We present our preliminarily results toward an enterprise-wide PACS intended to support all kind of image production in medicine, from biomolecular images to whole-body pictures. Our solution is based on an existing radiologic PACS system from which images are distributed through an electronic patient record to all care facilities. This platform is enriched with a flexible integration framework supporting digital image communication in medicine (DICOM) and DICOM-XML formats. In addition, a generic workflow engine highly customizable is used to drive work processes. Echocardiology; hematology; ear, nose, and throat; and dermatology, including wounds, follow-up is the first implemented extensions outside of radiology. We also propose a global strategy for further developments based on three possible architectures for an enterprise-wide PACS.

  3. Deep Learning in Radiology.

    PubMed

    McBee, Morgan P; Awan, Omer A; Colucci, Andrew T; Ghobadi, Comeron W; Kadom, Nadja; Kansagra, Akash P; Tridandapani, Srini; Auffermann, William F

    2018-03-29

    As radiology is inherently a data-driven specialty, it is especially conducive to utilizing data processing techniques. One such technique, deep learning (DL), has become a remarkably powerful tool for image processing in recent years. In this work, the Association of University Radiologists Radiology Research Alliance Task Force on Deep Learning provides an overview of DL for the radiologist. This article aims to present an overview of DL in a manner that is understandable to radiologists; to examine past, present, and future applications; as well as to evaluate how radiologists may benefit from this remarkable new tool. We describe several areas within radiology in which DL techniques are having the most significant impact: lesion or disease detection, classification, quantification, and segmentation. The legal and ethical hurdles to implementation are also discussed. By taking advantage of this powerful tool, radiologists can become increasingly more accurate in their interpretations with fewer errors and spend more time to focus on patient care. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  4. Issues around radiological protection of the environment and its integration with protection of humans: promoting debate on the way forward.

    PubMed

    Brownless, G P

    2007-12-01

    This paper explores issues to consider around integrating direct, explicit protection of the environment into the current system of radiological protection, which is focused on the protection of humans. Many issues around environmental radiological protection have been discussed, and ready-to-use toolboxes have been constructed for assessing harm to non-human biota, but it is not clear how (or even if) these should be fitted into the current system of protection. Starting from the position that the current approach to protecting the environment (namely that it follows from adequately protecting humans) is generally effective, this paper considers how explicit radiological protection of the environment can be integrated with the current system, through developing a 'worked example' of how this could be done and highlighting issues peculiar to protection of the environment. The aim of the paper is to promote debate on this topic, with the ultimate aim of ensuring that any changes to the system are consensual and robust.

  5. Radiology operations: what you don't know could be costing you millions.

    PubMed

    Joffe, Sam; Drew, Donna; Bansal, Manju; Hase, Michael

    2007-01-01

    Rapid growth in advanced imaging procedures has left hospital radiology departments struggling to keep up with demand, resulting in loss of patients to facilities that can offer service more quickly. While the departments appear to be working at full capacity, an operational analysis of over 400 hospital radiology departments in the US by GE Healthcare has determined that, paradoxically, many departments are in fact underutilized and operating for below their potential capacity. While CT cycle time in hospitals that were studied averaged 35 minutes, top performing hospitals operated the same equipment at a cycle time of 15 minutes, yielding approximately double the throughput volume. Factors leading to suboptimal performance include accounting metrics that mask true performance, leadership focus on capital investment rather than operations, under staffing, under scheduling, poorly aligned incentives, a fragmented view of operations, lack of awareness of latent opportunities, and lack of sufficient skills and processes to implement improvements. The study showed how modest investments in radiology operations can dramatically improve access to services and profitability.

  6. Teaching surgery, radiology and anatomy together: the mix enhances motivation and comprehension.

    PubMed

    Dettmer, Sabine; Tschernig, Thomas; Galanski, Michael; Pabst, Reinhard; Rieck, Bernd

    2010-10-01

    Preclinical and clinical topics are often separated in medical education. For example, surgery and radiology are often taught much later than anatomy. The aim of this study was to establish and to evaluate an interdisciplinary course combining these closely related subjects to enhance medical comprehension. Two tutorials each lasting one term were offered to second year medical students, in which clinical topics were implemented linking anatomy to surgical and radiological knowledge. A questionnaire was used to evaluate the success of this approach. The motivation of the students was above average and the practical work was done accurately. The students confirmed that the course improved anatomical comprehension (>95%) and that the learned matters were relevant for their future (90%). Furthermore, interest in the subjects was higher after the course (>85%). Critical suggestions were to extend the course and to include more topics. A mix of surgery, radiology and anatomy is a teaching concept, which leads to high acceptance and interest in medical students.

  7. Hydrodeoxygenation of fast-pyrolysis bio-oils from various feedstocks using carbon-supported catalysts

    USDA-ARS?s Scientific Manuscript database

    While much work has been accomplished in developing hydrodeoxygenation technologies for bio-oil upgrading, very little translation has occurred to other biomass feedstocks and feedstock processing technologies. In this paper, we sought to elucidate the relationships between the feedstock type and th...

  8. Selling to Industry for Sheltered Workshops.

    ERIC Educational Resources Information Center

    Rehabilitation Services Administration (DHEW), Washington, DC.

    Intended for staffs of sheltered workshops for handicapped individuals, the guide presents a plan for selling the workshop idea to industry, hints on meeting obstacles, and ideas for expanding and upgrading workshop contract promotion. Brief sections cover the following topics (example subtopics are in parentheses): finding work contract prospects…

  9. 75 FR 68781 - Workforce Guidelines for Home Energy Upgrades

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-09

    ... Work Specifications (SWSs), Job Task Analyses (JTAs) and essential Knowledge, Skills and Abilities..., organized labor, healthy homes and worker safety experts, and other professionals in the building trades and... reviews, a healthy homes review coordinated by the EPA, and a worker health and safety review coordinated...

  10. 23 CFR 645.105 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... phase of a project. The date of authorization establishes the date of eligibility for Federal funds to participate in the costs incurred on that phase of work. Betterment—any upgrading of the facility being... new location, moving, rearranging or changing the type of existing facilities and taking any necessary...

  11. 23 CFR 645.105 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... phase of a project. The date of authorization establishes the date of eligibility for Federal funds to participate in the costs incurred on that phase of work. Betterment—any upgrading of the facility being... new location, moving, rearranging or changing the type of existing facilities and taking any necessary...

  12. 23 CFR 645.105 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... phase of a project. The date of authorization establishes the date of eligibility for Federal funds to participate in the costs incurred on that phase of work. Betterment—any upgrading of the facility being... new location, moving, rearranging or changing the type of existing facilities and taking any necessary...

  13. 23 CFR 645.105 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... phase of a project. The date of authorization establishes the date of eligibility for Federal funds to participate in the costs incurred on that phase of work. Betterment—any upgrading of the facility being... new location, moving, rearranging or changing the type of existing facilities and taking any necessary...

  14. Final Flame Trench Brick Installation at Launch Pad 39B

    NASA Image and Video Library

    2017-05-09

    A view of the north side of the flame trench at Launch Complex 39B at NASA's Kennedy Space Center in Florida. The final brick was installed in the flame trench, completing about a year's worth of work to upgrade the walls to withstand the intense heat and fire at launch of NASA's Space Launch System rocket with Orion atop. About 96,000 heat-resistant bricks, in three different sizes, were secured to the walls using bonding mortar in combination with adhesive anchors. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to Pad 39B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1 and NASA’s journey to Mars.

  15. ML Construction Progress

    NASA Image and Video Library

    2014-12-17

    Modifications continue on the Mobile Launcher, or ML, at the Mobile Launcher Park Site at NASA’s Kennedy Space Center in Florida. A crane is being used to move scaffolding, or work platforms, around the base of the tower on the ML to continue upgrades and modifications to the structure. The ML is being modified and strengthened to accommodate the weight, size and thrust at launch of NASA's Space Launch System, or SLS, and Orion spacecraft. The ML is one of the key elements of ground support equipment that is being upgraded by the Ground Systems Development and Operations Program at Kennedy. The ML will carry the SLS rocket and Orion spacecraft to Launch Pad 39B for its first uncrewed mission, Exploration Mission-1, in 2018.

  16. Lessons Learned from the Construction of Upgrades to the NASA Glenn Icing Research Tunnel and Re-activation Testing

    NASA Technical Reports Server (NTRS)

    Sheldon, David W.; Andracchio, Charles R.; Krivanek, Thomas M.; Spera, David A.; Austinson, Todd A.

    2001-01-01

    Major upgrades were made in 1999 to the 6- by 9-Foot (1.8- by 2.7-m) Icing Research Tunnel (IRT) at the NASA Glenn Research Center. These included replacement of the electronic controls for the variable-speed drive motor, replacement of the heat exchanger, complete replacement and enlargement of the leg of the tunnel containing the new heat-exchanger, the addition of flow-expanding and flow-contracting turning vanes upstream and downstream of the heat exchanger, respectively, and the addition of fan outlet guide vanes (OGV's). This paper presents an overview of the construction and reactivation testing phases of the project. Important lessons learned during the technical and contract management work are documented.

  17. Information extraction from multi-institutional radiology reports.

    PubMed

    Hassanpour, Saeed; Langlotz, Curtis P

    2016-01-01

    The radiology report is the most important source of clinical imaging information. It documents critical information about the patient's health and the radiologist's interpretation of medical findings. It also communicates information to the referring physicians and records that information for future clinical and research use. Although efforts to structure some radiology report information through predefined templates are beginning to bear fruit, a large portion of radiology report information is entered in free text. The free text format is a major obstacle for rapid extraction and subsequent use of information by clinicians, researchers, and healthcare information systems. This difficulty is due to the ambiguity and subtlety of natural language, complexity of described images, and variations among different radiologists and healthcare organizations. As a result, radiology reports are used only once by the clinician who ordered the study and rarely are used again for research and data mining. In this work, machine learning techniques and a large multi-institutional radiology report repository are used to extract the semantics of the radiology report and overcome the barriers to the re-use of radiology report information in clinical research and other healthcare applications. We describe a machine learning system to annotate radiology reports and extract report contents according to an information model. This information model covers the majority of clinically significant contents in radiology reports and is applicable to a wide variety of radiology study types. Our automated approach uses discriminative sequence classifiers for named-entity recognition to extract and organize clinically significant terms and phrases consistent with the information model. We evaluated our information extraction system on 150 radiology reports from three major healthcare organizations and compared its results to a commonly used non-machine learning information extraction method. We also evaluated the generalizability of our approach across different organizations by training and testing our system on data from different organizations. Our results show the efficacy of our machine learning approach in extracting the information model's elements (10-fold cross-validation average performance: precision: 87%, recall: 84%, F1 score: 85%) and its superiority and generalizability compared to the common non-machine learning approach (p-value<0.05). Our machine learning information extraction approach provides an effective automatic method to annotate and extract clinically significant information from a large collection of free text radiology reports. This information extraction system can help clinicians better understand the radiology reports and prioritize their review process. In addition, the extracted information can be used by researchers to link radiology reports to information from other data sources such as electronic health records and the patient's genome. Extracted information also can facilitate disease surveillance, real-time clinical decision support for the radiologist, and content-based image retrieval. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    Homeland Security Presidential Directive HSPD-5 requires all federal departments and agencies to adopt a National Incident Management System (NIMS)/Incident Command System (ICS) and use it in their individual domestic incident management and emergency prevention, preparedness, response, recovery, and mitigation programs and activities, as well as in support of those actions taken to assist state and local entities. This system provides a consistent nationwide template to enable federal, state, local, and tribal governments, private-sector, and nongovernmental organizations to work together effectively and efficiently to prepare for, prevent, respond to, and recover from domestic incidents, regardless of cause, size, or complexity, includingmore » acts of catastrophic terrorism. This document identifies the operational concepts of the Federal Radiological Monitoring and Assessment Center's (FRMAC) implementation of the NIMS/ICS response structure under the National Response Plan (NRP). The construct identified here defines the basic response template to be tailored to the incident-specific response requirements. FRMAC's mission to facilitate interagency environmental data management, monitoring, sampling, analysis, and assessment and link this information to the planning and decision staff clearly places the FRMAC in the Planning Section. FRMAC is not a mitigating resource for radiological contamination but is present to conduct radiological impact assessment for public dose avoidance. Field monitoring is a fact-finding mission to support this effort directly. Decisions based on the assessed data will drive public protection and operational requirements. This organizational structure under NIMS is focused by the mission responsibilities and interface requirements following the premise to provide emergency responders with a flexible yet standardized structure for incident response activities. The coordination responsibilities outlined in the NRP are based on the NIMS/ICS construct and Unified Command (UC) for management of a domestic incident. The NRP Nuclear/Radiological Incident Annex (NUC) further provides requirements and protocols for coordinating federal government capabilities to respond to nuclear/radiological Incidents of National Significance (INS) and other radiological incidents. When a FRMAC is established, it operates under the parameters of NIMS as defined in the NRP. FRMAC and its operations have been modified to reflect NIMS/ICS concepts and principles and to facilitate working in a Unified Command structure. FRMAC is established at or near the scene of the incident to coordinate radiological monitoring and assessment and is established in coordination with the U.S. Department of Homeland Security (DHS); the coordinating agency; other federal agencies; and state, local, and tribal authorities. However, regardless of the coordinating agency designation, U.S. Department of Energy (DOE) coordinates radiological monitoring and assessment activities for the initial phases of the offsite federal incident response through the Radiological Assistance Program (RAP) and FRMAC assets. Monitoring and assessment data are managed by FRMAC in an accountable, secure, and retrievable format. Monitoring data interpretations, including exposure rate contours, dose projections, and any requested radiological assessments are to be provided to the DHS; to the coordinating agency; and to state, local, and tribal government agencies.« less

  19. Design of an image-distribution service from a clinical PACS

    NASA Astrophysics Data System (ADS)

    Gehring, Dale G.; Persons, Kenneth R.; Rothman, Melvyn L.; Felmlee, Joel P.; Gerhart, D. J.; Hangiandreou, Nicholas J.; Reardon, Frank J.; Shirk, M.; Forbes, Glenn S.; Williamson, Byrn, Jr.

    1994-05-01

    A PACS system has been developed through a multi-phase collaboration between the Mayo Clinic and IBM/Rochester. The current system has been fully integrated into the clinical practice of the Radiology Department for the primary purpose of digital image archival, retrieval, and networked workstation review. Work currently in progress includes the design and implementation of a gateway device for providing digital image data to third-party workstations, laser printers, and other devices, for users both within and outside of the Radiology Department.

  20. Increasing diversity in radiologic technology.

    PubMed

    Carwile, Laura

    2003-01-01

    Diversity is increasingly important in the radiologic technology workplace. For significant changes to occur in work force diversity, educators must first recruit and retain students from a wide variety of backgrounds. This article examines personality, race and gender as factors affecting career choice and how educators can use these factors to increase diversity in their programs. An overview of the ASRT's efforts to improve diversity within the profession is presented, along with suggestions for developing effective recruitment and retention plans to increase diversity.

  1. Multiservice Tactics, Techniques, and Procedures for Chemical, Biological, Radiological and Nuclear Contamination Avoidance

    DTIC Science & Technology

    2006-02-01

    Radiological and Nuclear Contamination Avoidance 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK...NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND ADDRESS(ES) Federation of American Scientists 1717 K St., NW Suite 209 Washington...DC 20036 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM( S ) 11

  2. Managerial accounting applications in radiology.

    PubMed

    Lexa, Frank James; Mehta, Tushar; Seidmann, Abraham

    2005-03-01

    We review the core issues in managerial accounting for radiologists. We introduce the topic and then explore its application to diagnostic imaging. We define key terms such as fixed cost, variable cost, marginal cost, and marginal revenue and discuss their role in understanding the operational and financial implications for a radiology facility by using a cost-volume-profit model. Our work places particular emphasis on the role of managerial accounting in understanding service costs, as well as how it assists executive decision making.

  3. Serving, Following, and Leading in Health Care.

    PubMed

    Penny, Steven M

    2017-07-01

    Radiologic technologists often perform diverse roles throughout the workday, and they should have at least a minimal understanding of the responsibility and effects of these roles on the patient and organization. Although technologists can practice independently or as part of a work group, individuals should be prepared to improve patient care and to function as a servant, follower, and leader for the overall success of the organization. This article examines those roles, emphasizing servantship. ©2017 American Society of Radiologic Technologists.

  4. Using experience with bidirectional HL7-ACR-NEMA interfaces between the federal government HIS/RIS and commercial PACS to plan for DICOM

    NASA Astrophysics Data System (ADS)

    Kuzmak, Peter M.; Norton, Gary S.; Dayhoff, Ruth E.

    1995-05-01

    The Department of Veterans Affairs has developed a bidirectional HL7 - ACR-NEMA V 2.0 interface for connecting existing federal government hospital/radiology information systems (HIS/RIS) to commercial picture archive and communication systems (PACS). The interface has been in use since October 1993 at the Baltimore VAMC between the VA's HIS/RIS (DHCP) and a commercial PACS, and handles both text and image transfer. The text-only portion of the interface has been ported to work with a second vendor's PACS, and to work with the Department of Defense HIS/RIS (CHCS). Currently the interface is in production at two VA and three DoD sites. The common benefit experienced at all these sites is that passing patient, order, and report information directly from the HIS/RIS to the PACS greatly improves the flow of work in the Radiology Department. Image transfer to the DHCP Imaging System at the Baltimore VAMC demonstrated the advantage of providing `reference quality' (1K X 1K X 8-bit) radiology images to treating clinicians throughout the hospital. Experience has shown that the gateway must handle transactions between the HIS/RIS and the PACS quickly in order to keep up with the volume, and must provide an audit trail for system diagnostic purposes. Work is underway to construct a HL7 - DICOM gateway built upon the operational experience gathered from the existing interface.

  5. Clinical and radiological analysis of a series of periapical cysts and periapical granulomas diagnosed in a Brazilian population.

    PubMed

    Tavares, Daniel-Petitet; Rodrigues, Janderson-Teixeira; Dos Santos, Teresa-Cristina-Ribeiro-Bartholomeu; Armada, Luciana; Pires, Fábio-Ramôa

    2017-01-01

    Periapical cysts (PC) and periapical granulomas (PG) are the two most common chronic inflammatory periapical diseases, but their clinicoradiological characteristics can vary depending on the methods employed in each study. The aim of the present work was to analyze the clinical and radiological profile of a series of PC and PG diagnosed in a Brazilian population. The files of two Oral Pathology laboratories were reviewed and all cases diagnosed as PG and PC were selected for the study. Clinical and radiological information were retrieved and data were tabulated and descriptively and comparatively analyzed. Final sample was composed by 647 inflammatory periapical lesions, including 244 PG (38%) and 403 PC (62%). The number of women affected by PG was significantly higher than the number of women affected by PC ( p =0.037). Anterior region of the maxilla was the most common affected area for both entities (39% of the cases), but the most common anatomical location of PG (anterior maxilla and posterior maxilla) was different from PC (anterior maxilla and posterior mandible) ( p <0.0001). Upper lateral incisor was the most affected tooth. The mean radiological size of the PC was larger than the mean radiological size of the PG ( p <0.0001) and PC showed well-defined radiological images more frequently than PG ( p <0.0001). PC were more common than PG, both showed predilection for adult females, most lesions affected predominantly the anterior maxilla and PC presented larger mean radiological diameter and well-defined images when compared with PG. Key words: Periapical granuloma, periapical cyst, radicular cyst, diagnosis, Oral Pathology.

  6. PATHWAYS TO HEALTH CAREERS, EXPLORING HEALTH OCCUPATIONS AND PROFESSIONS.

    ERIC Educational Resources Information Center

    Health Careers Council of Illinois, Chicago.

    CAREERS IN THE AREAS OF DENTISTRY, DIETETICS, MEDICAL RECORD LIBRARY SCIENCE, MEDICAL LABORATORY WORK, MEDICINE, NURSING, OCCUPATIONAL THERAPY, OPTOMETRY, PHARMACY, PHYSICAL THERAPY, PODIATRY, PUBLIC HEALTH, RADIOLOGIC TECHNOLOGY, SOCIAL WORK, VETERINARY MEDICINE, HOSPITAL ADMINISTRATION, AND OTHER HEALTH OCCUPATIONS ARE DESCRIBED IN TERMS OF THE…

  7. HOW DO RADIOLOGISTS USE THE HUMAN SEARCH ENGINE?

    PubMed

    Wolfe, Jeremy M; Evans, Karla K; Drew, Trafton; Aizenman, Avigael; Josephs, Emilie

    2016-06-01

    Radiologists perform many 'visual search tasks' in which they look for one or more instances of one or more types of target item in a medical image (e.g. cancer screening). To understand and improve how radiologists do such tasks, it must be understood how the human 'search engine' works. This article briefly reviews some of the relevant work into this aspect of medical image perception. Questions include how attention and the eyes are guided in radiologic search? How is global (image-wide) information used in search? How might properties of human vision and human cognition lead to errors in radiologic search? © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Opening

    ScienceCinema

    Bruning, Oliver

    2018-05-23

    Overview of the operation and upgrade plans for the machine. Upgrade studies and taskforces. The Chamonix 2010 discussions led to five new task forces: planning for a long shut down in 2012 for splice consolidation; long term consolidation planning for the injector complex; SPS upgrade task force (accelerated program for SPS upgrade); PSB upgrade and its implications for the PS (e.g. radiation etc.); LHC High Luminosity project (investigate planning for ONE upgrade by 2018-2020); Launch of a dedicated study for doubling the beam energy in the LHC->HE-LHC.

  9. Integrated science building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conklin, Shane

    2013-09-30

    Shell space fit out included faculty office advising space, student study space, staff restroom and lobby cafe. Electrical, HVAC and fire alarm installations and upgrades to existing systems were required to support the newly configured spaces. These installations and upgrades included audio/visual equipment, additional electrical outlets and connections to emergency generators. The project provided increased chilled water capacity with the addition of an electric centrifugal chiller. Upgrades associated with chiller included upgrade of exhaust ventilation fan, electrical conductor and breaker upgrades, piping and upgrades to air handling equipment.

  10. Airborne Warning and Control System Block 40/45 Upgrade (AWACS Blk 40/45 Upgrade)

    DTIC Science & Technology

    2015-12-01

    Selected Acquisition Report ( SAR ) RCS: DD-A&T(Q&A)823-277 Airborne Warning and Control System Block 40/45 Upgrade (AWACS Blk 40/45 Upgrade) As of...Upgrade December 2015 SAR March 23, 2016 16:04:37 UNCLASSIFIED 2 Table of Contents Common Acronyms and Abbreviations for MDAP Programs 3 Program...Acquisition Unit Cost AWACS Blk 40/45 Upgrade December 2015 SAR March 23, 2016 16:04:37 UNCLASSIFIED 3 PB - President’s Budget PE - Program Element

  11. The Plate Boundary Observatory Cascadia Network: Development and Installation of a Large Scale Real-time GPS Network

    NASA Astrophysics Data System (ADS)

    Austin, K. E.; Blume, F.; Berglund, H. T.; Feaux, K.; Gallaher, W. W.; Hodgkinson, K. M.; Mattioli, G. S.; Mencin, D.

    2014-12-01

    The EarthScope Plate Boundary Observatory (PBO), through a NSF-ARRA supplement, has enhanced the geophysical infrastructure in in the Pacific Northwest by upgrading a total of 282 Plate Boundary Observatory GPS stations to allow the collection and distribution of high-rate (1 Hz), low-latency (<1 s) data streams (RT-GPS). These upgraded stations supplemented the original 100 RT-GPS stations in the PBO GPS network. The addition of the new RT-GPS sites in Cascadia should spur new volcano and earthquake research opportunities in an area of great scientific interest and high geophysical hazard. Streaming RT-GPS data will enable researchers to detect and investigate strong ground motion during large geophysical events, including a possible plate-interface earthquake, which has implications for earthquake hazard mitigation. A Mw 6.9 earthquake occurred on March 10, 2014, off the coast of northern California. As a response, UNAVCO downloaded high-rate GPS data from Plate Boundary Observatory stations within 500 km of the epicenter of the event, providing a good test of network performance.In addition to the 282 stations upgraded to real-time, 22 new meteorological instruments were added to existing PBO stations. Extensive testing of BGAN satellite communications systems has been conducted to support the Cascadia RT-GPS upgrades and the installation of three BGAN satellite fail over systems along the Cascadia margin will allow for the continuation of data flow in the event of a loss of primary communications during in a large geophysical event or other interruptions in commercial cellular networks. In summary, with these additional upgrades in the Cascadia region, the PBO RT-GPS network will increase to 420 stations. Upgrades to the UNAVCO data infrastructure included evaluation and purchase of the Trimble Pivot Platform, servers, and additional hardware for archiving the high rate data, as well as testing and implementation of GLONASS and Trimble RTX positioning on the receivers. UNAVCO staff is working closely with the UNAVCO community to develop data standards, protocols, and a science plan for the use of RT-GPS data.

  12. Social and health outcomes following upgrades to a national housing standard: a multilevel analysis of a five-wave repeated cross-sectional survey.

    PubMed

    Poortinga, Wouter; Jones, Nikki; Lannon, Simon; Jenkins, Huw

    2017-12-02

    While existing research indicates that housing improvements are associated with health improvements, less is known about the wider social and health benefits of meeting national housing standards, as well as those of their specific constituent measures. This study evaluates the impacts of a managed housing upgrade programme through a repeated cross-sectional survey design. A five-wave repeated cross-sectional survey was conducted over a seven-year period from 2009 to 2016 (n = 2075; n = 2219; n = 2015; n = 1991; and n = 1709, respectively). The study followed a managed upgrade programme designed to meet a national social housing standard over an extended period. The data were analysed from a multilevel perspective to take account of the time-dependent nature of the observations and differences in socio-demographic composition. The installation of the majority of individual housing measures (new windows and doors; boilers; kitchens; bathrooms; electrics; loft insulation; and cavity/external wall insulation) were associated with improvements in several social (housing suitability, satisfaction, and quality; thermal comfort and household finances) and health (mental, respiratory and general health) outcomes; and analyses showed relationships between the number of measures installed and the total amount invested on the one hand and the social and health outcomes on the other. There were however a few exceptions. Most notably, the installation of cavity wall insulation was associated with poorer health outcomes, and did not lead to better social outcomes. Also, no association was found between the number of measures installed and respiratory health. The study suggests that substantial housing investments through a managed upgrade programme may result in better social and health outcomes, and that the size of the improvements are proportionate to the number of measures installed and amount invested. However, there may be risks associated with specific measures; and more attention is needed for mechanical ventilation when upgrading energy efficiency of houses through fabric work. In addition to providing new evidence regarding the wider social and health outcomes, the study provides an analytical approach to evaluate upgrade programmes that are delivered over multiple years.

  13. Get a winning Oracle upgrade session using the quarterback approach

    NASA Technical Reports Server (NTRS)

    Anderson, G.

    2002-01-01

    Upgrades, upgrades... too much customer down time. Find out how we shrunk our production upgrade schedule 40% from our estimate of 10 days 12 hours to 6 days 2 hours using the quarterback approach. So your upgrade is not that complex, come anyway. This approach is scalable to any size project and will be extremely valuable.

  14. Evaluation of two selection tests for recruitment into radiology specialty training.

    PubMed

    Patterson, Fiona; Knight, Alec; McKnight, Liam; Booth, Thomas C

    2016-07-11

    This study evaluated whether two selection tests previously validated for primary care General Practice (GP) trainee selection could provide a valid shortlisting selection method for entry into specialty training for the secondary care specialty of radiology. We conducted a retrospective analysis of data from radiology applicants who also applied to UK GP specialty training or Core Medical Training. The psychometric properties of the two selection tests, a clinical problem solving (CPS) test and situational judgement test (SJT), were analysed to evaluate their reliability. Predictive validity of the tests was analysed by comparing them with the current radiology selection assessments, and the licensure examination results taken after the first stage of training (Fellowship of the Royal College of Radiologists (FRCR) Part 1). The internal reliability of the two selection tests in the radiology applicant sample was good (α ≥ 0.80). The average correlation with radiology shortlisting selection scores was r = 0.26 for the CPS (with p < 0.05 in 5 of 11 shortlisting centres), r = 0.15 for the SJT (with p < 0.05 in 2 of 11 shortlisting centres) and r = 0.25 (with p < 0.05 in 5 of 11 shortlisting centres) for the two tests combined. The CPS test scores significantly correlated with performance in both components of the FRCR Part 1 examinations (r = 0.5 anatomy; r = 0.4 physics; p < 0.05 for both). The SJT did not correlate with either component of the examination. The current CPS test may be an appropriate selection method for shortlisting in radiology but would benefit from further refinement for use in radiology to ensure that the test specification is relevant. The evidence on whether the SJT may be appropriate for shortlisting in radiology is limited. However, these results may be expected to some extent since the SJT is designed to measure non-academic attributes. Further validation work (e.g. with non-academic outcome variables) is required to evaluate whether an SJT will add value in recruitment for radiology specialty training and will further inform construct validity of SJTs as a selection methodology.

  15. Burbank works on the EPIC in the Node 2

    NASA Image and Video Library

    2012-02-28

    ISS030-E-114433 (29 Feb. 2012) --- In the International Space Station?s Destiny laboratory, NASA astronaut Dan Burbank, Expedition 30 commander, upgrades Multiplexer/Demultiplexer (MDM) computers and Portable Computer System (PCS) laptops and installs the Enhanced Processor & Integrated Communications (EPIC) hardware in the Payload 1 (PL-1) MDM.

  16. Bosch CO2 Reduction System Development

    NASA Technical Reports Server (NTRS)

    Holmes, R. F.; King, C. D.; Keller, E. E.

    1976-01-01

    Development of a Bosch process CO2 reduction unit was continued, and, by means of hardware modifications, the performance was substantially improved. Benefits of the hardware upgrading were demonstrated by extensive unit operation and data acquisition in the laboratory. This work was accomplished on a cold seal configuration of the Bosch unit.

  17. Business-Industry-Labor Involvement in Lifelong Vocational-Technical Education.

    ERIC Educational Resources Information Center

    Warmbrod, Catharine P.

    The knowledge explosion dramatizes the need for education throughout peoples' lives, while technological change in particular fuels business, industry, and labor's imperative to cooperate closely with education to prepare people for work. In order to obtain the training, retraining, upgrading, and recycling of persons and skills, changes in work…

  18. Rewiring a Working Library or Teaching an Old Dog New Tricks.

    ERIC Educational Resources Information Center

    White, Robert L.; Jaffe, Lee David

    1995-01-01

    This case study describes the planning, funding, and implementation of a complete data-wiring renovation at the University of California, Santa Cruz library. Highlights include design principles; project schedule; benefits for staff's electronic mail and network use and for upgraded public terminals; and the importance of planning and…

  19. Institutional Renewal: A Necessity for Survival.

    ERIC Educational Resources Information Center

    Stone, Gordon L.

    A Professional Development Committee at Sault College of Applied Arts and Technology developed a renewal program to allow faculty members to upgrade their skills and abilities through participation in workshops, conferences, academic classes, and various off-campus work projects. Any faculty member desiring renewal funds was required to submit an…

  20. The MOUSE Squad

    ERIC Educational Resources Information Center

    Borja, Rhea R.

    2004-01-01

    This article presents a New York city after-school program started by MOUSE (Making Opportunities for Upgrading Schools and Education), a national nonprofit group that teaches students how to fix computers, and equips them with the communication and problem-solving skills to help them in the working world. The MOUSE program is part of a trend…

  1. Student Support that Works: A Solid Approach.

    ERIC Educational Resources Information Center

    Lang, Kathy J.; Bielejeski, Ruth

    The College of Saint Benedict and Saint John's University (Minnesota), two coordinate, liberal arts colleges, have implemented a cost-effective student information technology (IT) support system. Project IMPACT (Implementing Academic Technology), a 5-year, $10 million plan to upgrade the technology for student and faculty use, was implemented in…

  2. 75 FR 79418 - Request for Certification of Compliance-Rural Industrialization Loan and Grant Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-20

    ... 4279-2) for the following: Applicant/Location: Mt. Vernon Seafoods, LLC, Burlington, Washington... ship; purchase equipment, materials and machinery; perform upgrades to factory processor and company owned ship; and to create working capital. The office is to be located in Burlington, Washington. The...

  3. Upgrade Your Teaching Creds

    ERIC Educational Resources Information Center

    Blumenfeld, Lucinda

    2007-01-01

    A teacher has to keep going to school just to keep his or her job, so it pays to know the most interesting and convenient programs available. This article presents 11 professional development options that "work" for teachers' real-life schedules: (1) Best for Children's Literature: Penn State University; (2) Best for Science & Technology: PBS…

  4. Health Care Industry. Workforce & Workplace Literacy Series.

    ERIC Educational Resources Information Center

    BCEL Brief, 1991

    1991-01-01

    This brief gives an overview of the topic of workplace literacy in the health care industry and lists program contacts. The following 35 organizations operate basic skills upgrading programs for health care workers: American Hospital Association; Chinese American Civic Association; Massachusetts Department of Employment and Training; BostonWorks;…

  5. Confronting a Career Myth: The Case of Rhonda.

    ERIC Educational Resources Information Center

    Johnson, Richard W.; Silva, Santiago

    1990-01-01

    Responds to case of 34-year-old White female employee relations assistant who lost her job when it was upgraded to a position for which she was unqualified. Discusses information needed by counselor who might work with this client through the corporation's Employee Assistance Program and considers an intervention strategy. (NB)

  6. Carpentry. Performance Objectives. Basic Course.

    ERIC Educational Resources Information Center

    Downing, C. L.; Adcox, John W., Jr.

    Several intermediate performance objectives and corresponding criterion measures are listed for each of 12 terminal objectives in this course guide in basic carpentry. The guide is designed to prepare persons for initial employment, or to upgrade or retrain persons already employed, or to provide the apprenticeship related course work necessary to…

  7. A nuclear scanning method for estimating wear level nonuniformities

    NASA Astrophysics Data System (ADS)

    Ivanov, E. A.; Pascovici, G.; Racolta, P. M.

    1993-09-01

    The residual radioactivity measuring method has been upgraded to estimate wear level nonuniformities in the circumference of a piston ring after a certain working time in the combustion engine testing bench. The piston ring was irradiated by the thin layer activation (TLA) technique and its radioactivity was continuously monitored.

  8. New Careers, A Basic Strategy Against Poverty.

    ERIC Educational Resources Information Center

    Riessman, Frank

    The New Careers concept involves helping the disadvantaged to help themselves by offering them entry level jobs with the opportunity for training and advancement. New Careers provides the means to upgrade from entry level to professional occupations, with time made available during the work day for the education and training necessary for…

  9. Assessing task-technology fit in a PACS upgrade: do users' and developers' appraisals converge?

    PubMed

    Lepanto, Luigi; Sicotte, Claude; Lehoux, Pascale

    2011-12-01

    The purpose of this study was to measure users' perceived benefits of a picture archiving and communication system (PACS) upgrade, and compare their responses to those predicted by developers. The Task-Technology Fit (TTF) model served as the theoretical framework to study the relation between TTF, utilization, and perceived benefits. A self-administered survey was distributed to radiologists working in a university hospital undergoing a PACS upgrade. Four variables were measured: impact, utilization, TTF, and perceived net benefits. The radiologists were divided into subgroups according to their utilization profiles. Analysis of variance was performed and the hypotheses were tested with regression analysis. Interviews were conducted with developers involved in the PACS upgrade who were asked to predict impact and TTF. Users identified only a moderate fit between the PACS enhancements and their tasks, while developers predicted a high level of TTF. The combination of a moderate fit and an underestimation of the potential impact of changes in the PACS led to a low score for perceived net benefits. Results varied significantly among user subgroups. Globally, the data support the hypotheses that TTF predicts utilization and perceived net benefits, but not that utilization predicts perceived net benefits. TTF is a valid tool to assess perceived benefits, but it is important to take into account the characteristics of users. In the context of a technology that is rapidly evolving, there needs to be an alignment of what users perceive as a good fit and the functionality developers incorporate into their products.

  10. Tritium Plasma Experiment Upgrade and Improvement of Surface Diagnostic Capabilities at STAR Facility for Enhancing Tritium and Nuclear PMI Sciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shimada, M.; Taylor, C. N.; Pawelko, R. J.

    2016-04-01

    The Tritium Plasma Experiment (TPE) is a unique high-flux linear plasma device that can handle beryllium, tritium, and neutron-irradiated plasma facing materials, and is the only existing device dedicated to directly study tritium retention and permeation in neutron-irradiated materials with tritium [M. Shimada et.al., Rev. Sci. Instru. 82 (2011) 083503 and and M. Shimada, et.al., Nucl. Fusion 55 (2015) 013008]. The plasma-material-interaction (PMI) determines a boundary condition for diffusing tritium into bulk PFCs, and the tritium PMI is crucial for enhancing fundamental sciences that dictate tritium fuel cycles and safety and are high importance to an FNSF and DEMO. Recentlymore » the TPE has undergone major upgrades in its electrical and control systems. New DC power supplies and a new control center enable remote plasma operations from outside of the contamination area for tritium, minimizing the possible exposure risk with tritium and beryllium. We discuss the electrical upgrade, enhanced operational safety, improved plasma performance, and development of optical spectrometer system. This upgrade not only improves operational safety of the worker, but also enhances plasma performance to better simulate extreme plasma-material conditions expected in ITER, Fusion Nuclear Science Facility (FNSF), and Demonstration reactor (DEMO). This work was prepared for the U.S. Department of Energy, Office of Fusion Energy Sciences, under the DOE Idaho Field Office contract number DE-AC07-05ID14517.« less

  11. TCS and peripheral robotization and upgrade on the ESO 1-meter telescope at La Silla Observatory

    NASA Astrophysics Data System (ADS)

    Ropert, S.; Suc, V.; Jordán, A.; Tala, M.; Liedtke, P.; Royo, S.

    2016-07-01

    In this work we describe the robotization and upgrade of the ESO 1m telescope located at La Silla Observatory. The ESO 1m telescope was the first telescope installed in La Silla, in 1966. It now hosts as a main instrument the FIber Dual EchellE Optical Spectrograph (FIDEOS), a high resolution spectrograph designed for precise Radial Velocity (RV) measurements on bright stars. In order to meet this project's requirements, the Telescope Control System (TCS) and some of its mechanical peripherals needed to be upgraded. The TCS was also upgraded into a modern and robust software running on a group of single board computers interacting together as a network with the CoolObs TCS developed by ObsTech. One of the particularities of the CoolObs TCS is that it allows to fuse the input signals of 2 encoders per axis in order to achieve high precision and resolution of the tracking with moderate cost encoders. One encoder is installed on axis at the telescope and the other on axis at the motor. The TCS was also integrated with the FIDEOS instrument system so that all the system can be controlled through the same remote user interface. Our modern TCS unit allows the user to run observations remotely through a secured internet web interface, minimizing the need of an on-site observer and opening a new age in robotic astronomy for the ESO 1m telescope.

  12. CD-based image archival and management on a hybrid radiology intranet.

    PubMed

    Cox, R D; Henri, C J; Bret, P M

    1997-08-01

    This article describes the design and implementation of a low-cost image archival and management solution on a radiology network consisting of UNIX, IBM personal computer-compatible (IBM, Purchase, NY) and Macintosh (Apple Computer, Cupertino, CA) workstations. The picture archiving and communications system (PACS) is modular, scaleable and conforms to the Digital Imaging and Communications in Medicine (DICOM) 3.0 standard for image transfer, storage and retrieval. Image data is made available on soft-copy reporting workstations by a work-flow management scheme and on desktop computers through a World Wide Web (WWW) interface. Data archival is based on recordable compact disc (CD) technology and is automated. The project has allowed the radiology department to eliminate the use of film in magnetic resonance (MR) imaging, computed tomography (CT) and ultrasonography.

  13. The Relative Value Unit: History, Current Use, and Controversies.

    PubMed

    Baadh, Amanjit; Peterkin, Yuri; Wegener, Melanie; Flug, Jonathan; Katz, Douglas; Hoffmann, Jason C

    2016-01-01

    The relative value unit (RVU) is an important measuring tool for the work performed by physicians, and is currently used in the United States to calculate physician reimbursement. An understanding of radiology RVUs and current procedural terminology codes is important for radiologists, trainees, radiology managers, and administrators, as this knowledge would help them to understand better their current productivity and reimbursement, as well as controversies regarding reimbursement, and permit them to adapt to reimbursement changes that may occur in the future. This article reviews the components of the RVU and how radiology payment is calculated, highlights trends in RVUs and resultant payment for diagnostic and therapeutic imaging and examinations, and discusses current issues involving RVU and current procedural terminology codes. Copyright © 2015 Mosby, Inc. All rights reserved.

  14. Weld Repair of a Stamped Pressure Vessel in a Radiologically Controlled Zone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cannell, Gary L.; Huth, Ralph J.; Hallum, Randall T.

    2013-08-26

    In September 2012 an ASME B&PVC Section VIII stamped pressure vessel located at the DOE Hanford Site Effluent Treatment Facility (ETF) developed a through-wall leak. The vessel, a steam/brine heat exchanger, operated in a radiologically controlled zone (by the CH2MHill PRC or CHPRC), had been in service for approximately 17 years. The heat exchanger is part of a single train evaporator process and its failure caused the entire system to be shut down, significantly impacting facility operations. This paper describes the activities associated with failure characterization, technical decision making/planning for repair by welding, logistical challenges associated with performing work inmore » a radiologically controlled zone, performing the repair, and administrative considerations related to ASME code requirements.« less

  15. Complementary roles of interventional radiology and therapeutic endoscopy in gastroenterology

    PubMed Central

    Ray, David M; Srinivasan, Indu; Tang, Shou-Jiang; Vilmann, Andreas S; Vilmann, Peter; McCowan, Timothy C; Patel, Akash M

    2017-01-01

    Acute upper and lower gastrointestinal bleeding, enteral feeding, cecostomy tubes and luminal strictures are some of the common reasons for gastroenterology service. While surgery was initially considered the main treatment modality, the advent of both therapeutic endoscopy and interventional radiology have resulted in the paradigm shift in the management of these conditions. In this paper, we discuss the patient’s work up, indications, and complementary roles of endoscopic and angiographic management in the settings of gastrointestinal bleeding, enteral feeding, cecostomy tube placement and luminal strictures. These conditions often require multidisciplinary approaches involving a team of interventional radiologists, gastroenterologists and surgeons. Further, the authors also aim to describe how the fields of interventional radiology and gastrointestinal endoscopy are overlapping and complementary in the management of these complex conditions. PMID:28396724

  16. Performance of the upgraded Orroral laser ranging system

    NASA Technical Reports Server (NTRS)

    Luck, John M.

    1993-01-01

    The topics discussed include the following: upgrade arrangements, system prior to 1991, elements of the upgrade, laser performance, timing system performance, pass productivity, system precision, system accuracy, telescope pointing and future upgrades and extensions.

  17. Work productivity in rheumatoid arthritis: relationship with clinical and radiological features.

    PubMed

    Chaparro Del Moral, Rafael; Rillo, Oscar Luis; Casalla, Luciana; Morón, Carolina Bru; Citera, Gustavo; Cocco, José A Maldonado; Correa, María de Los Ángeles; Buschiazzo, Emilio; Tamborenea, Natalia; Mysler, Eduardo; Tate, Guillermo; Baños, Andrea; Herscovich, Natalia

    2012-01-01

    Objective. To assess the relationship between work productivity with disease activity, functional capacity, life quality and radiological damage in patients with rheumatoid arthritis (RA). Methods. The study included consecutive employed patients with RA (ACR'87), aged over 18. Demographic, disease-related, and work-related variables were determined. The reduction of work productivity was assessed by WPAI-RA. Results. 90 patients were evaluated, 71% women. Age average is 50 years old, DAS28 4, and RAQoL 12. Median SENS is 18 and HAQ-A 0.87. Mean absenteeism was of 14%, presenting an average of 6.30 work hours wasted weekly. The reduction in performance at work or assistance was of 38.4% and the waste of productivity was of 45%. Assistance correlated with DAS28 (r = 0.446; P < 0.001), HAQ-A (r = 0.545; P < 0.001) and RAQoL (r = 0.475; P < 0.001). Lower total productivity was noticed in higher levels of activity and functional disability. Patients with SENS > 18 showed lower work productivity than those with SENS < 18 (50 versus 34; P = 0.04). In multiple regression analysis, variables associated with reduction of total work productivity were HAQ-A and RAQoL. Conclusion. RA patients with higher disease severity showed higher work productivity compromise.

  18. Work Productivity in Rheumatoid Arthritis: Relationship with Clinical and Radiological Features

    PubMed Central

    Chaparro del Moral, Rafael; Rillo, Oscar Luis; Casalla, Luciana; Morón, Carolina Bru; Citera, Gustavo; Cocco, José A. Maldonado; Correa, María de los Ángeles; Buschiazzo, Emilio; Tamborenea, Natalia; Mysler, Eduardo; Tate, Guillermo; Baños, Andrea; Herscovich, Natalia

    2012-01-01

    Objective. To assess the relationship between work productivity with disease activity, functional capacity, life quality and radiological damage in patients with rheumatoid arthritis (RA). Methods. The study included consecutive employed patients with RA (ACR'87), aged over 18. Demographic, disease-related, and work-related variables were determined. The reduction of work productivity was assessed by WPAI-RA. Results. 90 patients were evaluated, 71% women. Age average is 50 years old, DAS28 4, and RAQoL 12. Median SENS is 18 and HAQ-A 0.87. Mean absenteeism was of 14%, presenting an average of 6.30 work hours wasted weekly. The reduction in performance at work or assistance was of 38.4% and the waste of productivity was of 45%. Assistance correlated with DAS28 (r = 0.446; P < 0.001), HAQ-A (r = 0.545; P < 0.001) and RAQoL (r = 0.475; P < 0.001). Lower total productivity was noticed in higher levels of activity and functional disability. Patients with SENS > 18 showed lower work productivity than those with SENS < 18 (50 versus 34; P = 0.04). In multiple regression analysis, variables associated with reduction of total work productivity were HAQ-A and RAQoL. Conclusion. RA patients with higher disease severity showed higher work productivity compromise. PMID:23320166

  19. MO-AB-204-00: Interoperability in Radiation Oncology: IHE-RO Committee Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    You’ve experienced the frustration: vendor A’s device claims to work with vendor B’s device, but the practice doesn’t match the promise. Getting devices working together is the hidden art that Radiology and Radiation Oncology staff have to master. To assist with that difficult process, the Integrating the Healthcare Enterprise (IHE) effort was established in 1998, with the coordination of the Radiological Society of North America. Integrating the Healthcare Enterprise (IHE) is a consortium of healthcare professionals and industry partners focused on improving the way computer systems interconnect and exchange information. This is done by coordinating the use of published standardsmore » like DICOM and HL7. Several clinical and operational IHE domains exist in the healthcare arena, including Radiology and Radiation Oncology. The ASTRO-sponsored IHE Radiation Oncology (IHE-RO) domain focuses on radiation oncology specific information exchange. This session will explore the IHE Radiology and IHE RO process for; IHE solicitation process for new profiles. Improving the way computer systems interconnect and exchange information in the healthcare enterprise Supporting interconnectivity descriptions and proof of adherence by vendors Testing and assuring the vendor solutions to connectivity problems. Including IHE profiles in RFPs for future software and hardware purchases. Learning Objectives: Understand IHE role in improving interoperability in health care. Understand process of profile development and implantation. Understand how vendors prove adherence to IHE RO profiles. S. Hadley, ASTRO Supported Activity.« less

  20. The discovery of radium in 1898 by Maria Sklodowska-Curie (1867-1934) and Pierre Curie (1859-1906) with commentary on their life and times.

    PubMed

    Mould, R F

    1998-12-01

    This review celebrates the events of 100 years ago to the month of publication of this December 1998 issue of the British Journal of Radiology, when radium was discovered by the Curies. This followed the earlier discovery in November 1895 of X-rays by Röntgen, which has already been reviewed in the British Journal of Radiology [1] and the discovery in March 1896, by Becquerel, of the phenomenon of radioactivity, which introduces this review. This is particularly relevant as Marie Curie was in 1897 a research student in Becquerel's laboratory. Marie Curie's life in Poland prior to her 1891 departure for Paris is included in this review as are other aspects of her life and work such as her work in World War I with radiological ambulances (known as "Little Curies") on the battlefields of France and Belgium, early experiments with radium and the founding of the Institut du Radium in Paris and of the Radium Institute in Warsaw. Wherever possible I have included appropriate quotations in Marie Curie's own words [2-4] and each section is related in some way to the life and work of Maria or Pierre. This review is completed with details of the re-interment of the bodies of Pierre and Marie on 20 April 1995 in The Panthéon, Paris.

  1. Commissioning of the CMS Hadron Forward Calorimeters Phase I Upgrade

    NASA Astrophysics Data System (ADS)

    Bilki, B.; Onel, Y.

    2018-03-01

    The final phase of the CMS Hadron Forward Calorimeters Phase I Upgrade was performed during the Extended Year End Technical Stop of 2016-2017. In the framework of the upgrade, the PMT boxes were reworked to implement two channel readout in order to exploit the benefits of the multi-anode PMTs in background tagging and signal recovery. The front-end electronics were also upgraded to QIE10-based electronics which implement larger dynamic range and a 6-bit TDC. Following this major upgrade, the Hadron Forward Calorimeters were commissioned for operation readiness in 2017. Here we describe the details and the components of the upgrade, and discuss the operational experience and results obtained during the upgrade and commissioning.

  2. 10 CFR 72.126 - Criteria for radiological protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... exposed to radiation or airborne radioactive materials. Structures, systems, and components for which... accessible work areas as appropriate to warn operating personnel of radiation and airborne radioactive...

  3. 76 FR 63622 - Meeting of the National Biodefense Science Board

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-13

    ... chemical, biological, nuclear, and radiological agents, whether naturally occurring, accidental, or... of the report and recommendations from the NBSB's Anthrax Vaccine Working Group. Subsequent agenda...

  4. Clinical compliance of viewing conditions in radiology reporting environments against current guidelines and standards

    NASA Astrophysics Data System (ADS)

    Daly, S.; Rainford, L.; Butler, M. L.

    2014-03-01

    Several studies have demonstrated the importance of environmental conditions in the radiology reporting environment, with many indicating that incorrect parameters could lead to error and misinterpretation. Literature is available with recommendations as to the levels that should be achieved in clinical practice, but evidence of adherence to these guidelines in radiology reporting environments is absent. This study audited the reporting environments of four teleradiologist and eight hospital based radiology reporting areas. This audit aimed to quantify adherence to guidelines and identify differences in the locations with respect to layout and design, monitor distance and angle as well as the ambient factors of the reporting environments. In line with international recommendations, an audit tool was designed to enquire in relation to the layout and design of reporting environments, monitor angle and distances used by radiologists when reporting, as well as the ambient factors such as noise, light and temperature. The review of conditions were carried out by the same independent auditor for consistency. The results obtained were compared against international standards and current research. Each radiology environment was given an overall compliance score to establish whether or not their environments were in line with recommended guidelines. Poor compliance to international recommendations and standards among radiology reporting environments was identified. Teleradiology reporting environments demonstrated greater compliance than hospital environments. The findings of this study identified a need for greater awareness of environmental and perceptual issues in the clinical setting. Further work involving a larger number of clinical centres is recommended.

  5. Decision theory applied to image quality control in radiology.

    PubMed

    Lessa, Patrícia S; Caous, Cristofer A; Arantes, Paula R; Amaro, Edson; de Souza, Fernando M Campello

    2008-11-13

    The present work aims at the application of the decision theory to radiological image quality control (QC) in diagnostic routine. The main problem addressed in the framework of decision theory is to accept or reject a film lot of a radiology service. The probability of each decision of a determined set of variables was obtained from the selected films. Based on a radiology service routine a decision probability function was determined for each considered group of combination characteristics. These characteristics were related to the film quality control. These parameters were also framed in a set of 8 possibilities, resulting in 256 possible decision rules. In order to determine a general utility application function to access the decision risk, we have used a simple unique parameter called r. The payoffs chosen were: diagnostic's result (correct/incorrect), cost (high/low), and patient satisfaction (yes/no) resulting in eight possible combinations. Depending on the value of r, more or less risk will occur related to the decision-making. The utility function was evaluated in order to determine the probability of a decision. The decision was made with patients or administrators' opinions from a radiology service center. The model is a formal quantitative approach to make a decision related to the medical imaging quality, providing an instrument to discriminate what is really necessary to accept or reject a film or a film lot. The method presented herein can help to access the risk level of an incorrect radiological diagnosis decision.

  6. Elevation of water table and various stratigraphic surfaces beneath e area low level waste disposal facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bagwell, Laura; Bennett, Patti

    2017-11-02

    This memorandum describes work that supports revision of the Radiological Performance Assessment (PA) for the E Area Low Level Radioactive Waste Disposal Facility (LLRWDF). The work summarized here addresses portions of the PA Strategic Planning Team's recommendation #148b (Butcher and Phifer, 2016).

  7. Radiological clinical trials: Proposal of a problem-finding questionnaire to improve study success.

    PubMed

    Valdora, Francesca; Bignotti, Bianca; Calabrese, Massimo; Houssami, Nehmat; Tagliafico, Alberto

    2016-12-26

    To develop a survey to help define the main problems in radiological clinical trials. Since 2006, we have managed seven different radiological clinical trials recruiting patients in academic and non-academic centres. We developed a preliminary questionnaire using a four-round Delphi approach to identify problems occurring in radiological clinical trials run at our centre. We investigated the recruitment experience, involvement of all multi-disciplinary team members and main obstacles to completing the projects. A final round of Delphi processes elucidated solutions to the identified problems. Among 19/20 (95%) respondents, 10 (53%) were young physicians (under 35 years old), and the respondents included non-faculty members, fellows, residents, and undergraduate students. Ninety-four percent (18/19) of respondents showed interest in conducting clinical trials. On a scale of 1 to 10, the problems with higher/worse scores (8-9) were related to technical or communication problems. The most frequent problems across all studies were technical problems related to clinical trial equipment, insufficient willingness to participate, obstacles to understanding the design of electronic-case report form and extra work. The developed questionnaire identified the main recurring problems in radiological clinical trials as perceived by end-users and helped define possible solutions that are mostly related to having dedicated clinical trial research staff.

  8. Improving Patient Safety: Avoiding Unread Imaging Exams in the National VA Enterprise Electronic Health Record.

    PubMed

    Bastawrous, Sarah; Carney, Benjamin

    2017-06-01

    In the current digital and filmless age of radiology, rates of unread radiology exams remain low, however, may still exist in unique environments. Veterans Affairs (VA) health care systems may experience higher rates of unread exams due to coexistence of Veterans Health Information Systems and Technology Architecture (VistA) imaging and commercial picture archiving and communication systems (PACS). The purpose of this patient safety initiative was to identify any unread exams and causes leading to unread exams. Following approval by departmental quality assurance committee, a comprehensive review was performed of all radiology exams within VistA imaging from July 1, 2009 to June 30, 2014 to identify unread radiology exams. Over the 5-year period, the total unread exam rate was calculated to be 0.17%, with the highest yearly unread exam rate of 0.25%. The leading majority of unread exam type was plain radiographs. Analysis revealed unfinished dictations, unassociated accession numbers, technologist errors, and inefficient radiologist work lists as top contributors to unread exams. Once unread radiology exams were discovered and the causes identified, valuable process changes were implemented within our department to ensure simultaneous tracking of all unread exams in VistA imaging as well as the commercial PACS.

  9. International Data on Radiological Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martha Finck; Margaret Goldberg

    2010-07-01

    ABSTRACT The mission of radiological dispersal device (RDD) nuclear forensics is to identify the provenance of nuclear and radiological materials used in RDDs and to aid law enforcement in tracking nuclear materials and routes. The application of databases to radiological forensics is to match RDD source material to a source model in the database, provide guidance regarding a possible second device, and aid the FBI by providing a short list of manufacturers and distributors, and ultimately to the last legal owner of the source. The Argonne/Idaho National Laboratory RDD attribution database is a powerful technical tool in radiological forensics. Themore » database (1267 unique vendors) includes all sealed sources and a device registered in the U.S., is complemented by data from the IAEA Catalogue, and is supported by rigorous in-lab characterization of selected sealed sources regarding physical form, radiochemical composition, and age-dating profiles. Close working relationships with global partners in the commercial sealed sources industry provide invaluable technical information and expertise in the development of signature profiles. These profiles are critical to the down-selection of potential candidates in either pre- or post- event RDD attribution. The down-selection process includes a match between an interdicted (or detonated) source and a model in the database linked to one or more manufacturers and distributors.« less

  10. Comprehensive innovative solution for resident education using the Intranet Journal of Chest Radiology.

    PubMed

    Nishino, Mizuki; Wolfe, Donna; Yam, Chun-Shan; Larson, Michael; Boiselle, Phillip M; Hatabu, Hiroto

    2004-10-01

    Because of the rapid increase in clinical workload in academic radiology departments, time for teaching rotating residents is getting more and more limited. As a solution to this problem, we introduced the Intranet Journal of Chest Radiology as a comprehensive innovative tool for assisting resident education. The Intranet Journal of Chest Radiology is constructed using Microsoft FrontPage version 2002 (Microsoft Corp, Redmond, WA) and is hosted in our departmental web server (Beth Israel Deaconess Medical Center, Boston, MA). The home page of the intranet journal provides access to the main features, "Cases of the Month," "Teaching File," "Selected Articles for Residents," "Lecture Series," and "Current Publications." These features provide quick access to the selected radiology articles, the interesting chest cases, and the lecture series and current publication from the chest section. Our intranet journal has been well utilized for 6 months after its introduction. It enhances residents' interest and motivation to work on case collections, to search and read articles, and to generate interest in research. Frequent updating is necessary for the journal to be kept current, relevant, and well-utilized. The intranet journal serves as a comprehensive innovative solution for resident education, providing basic educational resources and opportunities of interactive participation by residents.

  11. Work history and radioprotection practices in relation to cancer incidence and mortality in US radiologic technologists performing nuclear medicine procedures.

    PubMed

    Bernier, Marie Odile; Doody, Michele M; Van Dyke, Miriam E; Villoing, Daphné; Alexander, Bruce H; Linet, Martha S; Kitahara, Cari M

    2018-05-02

    Technologists working in nuclear medicine (NM) are exposed to higher radiation doses than most other occupationally exposed populations. The aim of this study was to estimate the risk of cancer in NM technologists in relation to work history, procedures performed and radioprotection practices. From the US Radiologic Technologists cohort study, 72 755 radiologic technologists who completed a 2003-2005 questionnaire were followed for cancer mortality through 31 December 2012 and for cancer incidence through completion of a questionnaire in 2012-2013. Multivariable-adjusted models were used to estimate HRs for total cancer incidence and mortality by history of ever performing NM procedures and frequency of performing specific diagnostic or therapeutic NM procedures and associated radiation protection measures by decade. During follow-up (mean=7.5 years), 960 incident cancers and 425 cancer deaths were reported among the 22 360 technologists who worked with NM procedures. We observed no increased risk of cancer incidence (HR 0.96, 95% CI 0.89 to 1.04) or death (HR 1.05, 95% CI 0.93 to 1.19) among workers who ever performed NM procedures. HRs for cancer incidence but not mortality were higher for technologists who began performing therapeutic procedures in 1960 and later compared with the 1950s. Frequency of performing diagnostic or therapeutic NM procedures and use of radioprotection measures were not consistently associated with cancer risk. No clear associations were observed for specific cancers, but results were based on small numbers. Cancer incidence and mortality were not associated with NM work history practices, including greater frequency of procedures performed. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Application of Oversampling to obtain the MTF of Digital Radiology Equipment.

    NASA Astrophysics Data System (ADS)

    Narváez, M.; Graffigna, J. P.; Gómez, M. E.; Romo, R.

    2016-04-01

    Within the objectives of theproject Medical Image Processing for QualityAssessment ofX Ray Imaging, the present research work is aimed at developinga phantomX ray image and itsassociated processing algorithms in order to evaluatethe image quality rendered by digital X ray equipment. These tools are used to measure various image parameters, among which spatial resolution shows afundamental property that can be characterized by the Modulation Transfer Function (MTF)of an imaging system [1]. After performing a thorough literature surveyon imaging quality control in digital X film in Argentine and international publications, it was decided to adopt for this work the Norm IEC 62220 1:2003 that recommends using an image edge as a testingmethod. In order to obtain the characterizing MTF, a protocol was designedfor unifying the conditions under which the images are acquired for later evaluation. The protocol implied acquiring a radiography image by means of a specific referential technique, i.e. referred either to voltage, current, time, distance focus plate (/film?) distance, or other referential parameter, and to interpret the image through a system of computed radiology or direct digital radiology. The contribution of the work stems from the fact that, even though the traditional way of evaluating an X film image quality has relied mostly on subjective methods, this work presents an objective evaluative toolfor the images obtained with a givenequipment, followed by a contrastive analysis with the renderings from other X filmimaging sets.Once the images were obtained, specific calculations were carried out. Though there exist some methods based on the subjective evaluation of the quality of image, this work offers an objective evaluation of the equipment under study. Finally, we present the results obtained on different equipment.

  13. Medical student radiology curriculum: what skills do residency program directors believe are essential for medical students to attain?

    PubMed

    Kondo, Kimi L; Swerdlow, Mathew

    2013-03-01

    The purpose of this study was to identify radiology topics considered essential by residency program directors who will be working with our graduates. Secondary goals were to survey their satisfaction with incoming residents' radiology knowledge, inquire if radiology training was provided in their programs, and identify differences among specialties. A questionnaire was mailed to all residency program directors in emergency medicine, family medicine, internal medicine, pediatrics, and general surgery programs that accepted our graduates between 2005 and 2010. Program directors were asked to rate a list of radiology knowledge and skills topics as essential or nonessential and to answer several questions regarding their residents and programs. Ninety-nine surveys were completed (51.3% response rate). Seven skills were considered essential by 90% or more of all respondents. On average, program directors identified 18/28 topics as essential prior to beginning their residency. The mean number identified as essential did not differ by program (F4, 93 = 0.732, P = .572). Based on analyses of variance comparing each topic by program, the importance of six topics differed significantly. Program directors generally agreed that incoming residents had adequate radiology skills and knowledge when they started their residencies. One hundred percent of the responding emergency medicine, family medicine, and pediatrics programs and 70% to 80% of the general surgery and internal medicine programs provide radiology training. There is high agreement among program directors regarding imaging topics they consider essential. Topics considered essential by more than 60% should comprise our core curriculum for all students while less essential topics can be included in elective or program specific curricula. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  14. Severe contrast reaction emergencies high-fidelity simulation training for radiology residents and technologists in a children's hospital.

    PubMed

    Tofil, Nancy M; White, Marjorie Lee; Grant, Matthew; Zinkan, J Lynn; Patel, Bhavik; Jenkins, Lynsey; Youngblood, Amber Q; Royal, Stuart A

    2010-07-01

    Severe reactions to radiographic contrast agents can be life threatening, and although they are rare, effective recognition and management are essential to improving outcomes. A high-fidelity radiology simulation course for radiology residents and technologists focusing on severe contrast reactions and immediate treatments was designed to test the hypothesis that knowledge would improve with this educational intervention. A prospective pretest and posttest study design was used. Residents and technologists worked in teams of three to five members. Learning objectives focused on demonstrating when and how to use basic life support skills and epinephrine auto-injectors. Each resident and technologist was administered a pretest prior to the start of the case scenarios and a posttest following the debriefing session. Scores from the pretest and posttest for the residents and technologists were compared using a paired-samples t test. Nineteen radiology residents and 11 radiology technologists participated. The average test scores were higher and improved significantly following the simulation experience for both the radiology residents (57% vs 82%, P < .001) and technologists (47% vs 72%, P = .006). Anonymous evaluations demonstrated that the experience was well received by residents and technologists, with 97% of learners (29 of 30) rating the experience as extremely or very helpful. Important learning themes included the knowledge of epinephrine auto-injector use and basic life support skills. High-fidelity simulation for radiology residents and technologists focusing on epinephrine auto-injector use and basic life support skills during the first 5 minutes of a severe contrast reaction can significantly improve recognition and knowledge in treating patients having severe contrast reactions. 2010 AUR. Published by Elsevier Inc. All rights reserved.

  15. Clinical and radiological analysis of a series of periapical cysts and periapical granulomas diagnosed in a Brazilian population

    PubMed Central

    Tavares, Daniel-Petitet; Rodrigues, Janderson-Teixeira; dos Santos, Teresa-Cristina-Ribeiro-Bartholomeu; Armada, Luciana

    2017-01-01

    Background Periapical cysts (PC) and periapical granulomas (PG) are the two most common chronic inflammatory periapical diseases, but their clinicoradiological characteristics can vary depending on the methods employed in each study. The aim of the present work was to analyze the clinical and radiological profile of a series of PC and PG diagnosed in a Brazilian population. Material and Methods The files of two Oral Pathology laboratories were reviewed and all cases diagnosed as PG and PC were selected for the study. Clinical and radiological information were retrieved and data were tabulated and descriptively and comparatively analyzed. Results Final sample was composed by 647 inflammatory periapical lesions, including 244 PG (38%) and 403 PC (62%). The number of women affected by PG was significantly higher than the number of women affected by PC (p=0.037). Anterior region of the maxilla was the most common affected area for both entities (39% of the cases), but the most common anatomical location of PG (anterior maxilla and posterior maxilla) was different from PC (anterior maxilla and posterior mandible) (p<0.0001). Upper lateral incisor was the most affected tooth. The mean radiological size of the PC was larger than the mean radiological size of the PG (p<0.0001) and PC showed well-defined radiological images more frequently than PG (p<0.0001). Conclusions PC were more common than PG, both showed predilection for adult females, most lesions affected predominantly the anterior maxilla and PC presented larger mean radiological diameter and well-defined images when compared with PG. Key words:Periapical granuloma, periapical cyst, radicular cyst, diagnosis, Oral Pathology. PMID:28149477

  16. Optics education for machine operators in the semiconductor industry: moving beyond button pushing

    NASA Astrophysics Data System (ADS)

    Karakekes, Meg; Currier, Deborah

    1995-10-01

    In the competitive semiconductor manufacturing industry, employees who operate equipment are able to make greater contributions if they understand how the equipment works. By understanding the 'why' behind the 'what', the equipment operators can better partner with other technical staff to produce quality integrated circuits efficiently and effectively. This additional knowledge also opens equipment operators to job enrichment and enlargement opportunities. Advanced Micro Devices (AMD) is in the process of upgrading the skills of its equipment operators. This paper is an overview of a pilot program that employs optics education to upgrade stepper operators' skills. The paper starts with stepper tasks that require optics knowledge, examines teaching methods, reports both end-of-course and three months post-training knowledge retention, and summarizes how the training has impacted the production floor.

  17. KSC-2014-1955

    NASA Image and Video Library

    2014-04-01

    CAPE CANAVERAL, Fla. – Inside the Vehicle Assembly Building at NASA’s Kennedy Space Center in Florida, ground support technicians install new roller bearings on the C truck of crawler-transporter 2, or CT-2. Work continues in high bay 2 to upgrade CT-2. The modifications are designed to ensure CT-2’s ability to transport launch vehicles currently in development, such as the agency’s Space Launch System, to the launch pad. The Ground Systems Development and Operations Program office at Kennedy is overseeing the upgrades. For more than 45 years the crawler-transporters were used to transport the mobile launcher platform and the Apollo-Saturn V rockets and, later, space shuttles to Launch Pads 39A and B. For more information, visit: http://www.nasa.gov/exploration/systems/ground/crawler-transporter. Photo credit: NASA/Cory Huston

  18. Upgrading of Intermediate Bio-Oil Produced by Catalytic Pyrolysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdullah, Zia; Chadwell, Brad; Taha, Rachid

    2015-06-30

    The objectives of this project were to (1) develop a process to upgrade catalytic pyrolysis bio-oil, (2) investigate new upgrading catalysts suited for upgrading catalytic pyrolysis bio-oil, (3) demonstrate upgrading system operation for more than 1,000 hours using a single catalyst charge, and (4) produce a final upgraded product that can be blended to 30 percent by weight with petroleum fuels or that is compatible with existing petroleum refining operations. This project has, to the best of our knowledge, for the first time enabled a commercially viable bio-oil hydrotreatment process to produce renewable blend stock for transportation fuels.

  19. Mass Storage System Upgrades at the NASA Center for Computational Sciences

    NASA Technical Reports Server (NTRS)

    Tarshish, Adina; Salmon, Ellen; Macie, Medora; Saletta, Marty

    2000-01-01

    The NASA Center for Computational Sciences (NCCS) provides supercomputing and mass storage services to over 1200 Earth and space scientists. During the past two years, the mass storage system at the NCCS went through a great deal of changes both major and minor. Tape drives, silo control software, and the mass storage software itself were upgraded, and the mass storage platform was upgraded twice. Some of these upgrades were aimed at achieving year-2000 compliance, while others were simply upgrades to newer and better technologies. In this paper we will describe these upgrades.

  20. Study of ELM Density Turbulence using the Upgraded Phase Contrast Imaging on DIII-D

    NASA Astrophysics Data System (ADS)

    Rost, J. C.; Davis, E. M.; Marinoni, A.; Porkolab, M.; Burrell, K. H.

    2016-10-01

    Recent studies of the turbulent density fluctuations accompanying ELMs in mixed ELM-type discharges have exploited the expanded wavenumber range of the upgraded Phase Contrast Imaging (PCI) diagnostic. The PCI data demonstrate the difference between the fluctuations generated by Type I ELMs, which are broadband in frequency and wavelength, and those generated by Type III ELMs, which are similar in amplitude but restricted to long wavelengths, suggesting that turbulence may play a significant role in Type I ELM transport. The high frequency response of PCI makes it ideal for studying the ELM-associated density fluctuations, which are observed at frequencies up to several MHz, evolve on time scales of 10s of μs, and persist after the magnetic component of the ELM has decayed away. The upgraded PCI, with independent systems for long and short wavelength detection (k < 5 cm-1 and 1 < k < 30 cm-1 respectively), demonstrated coverage of the full wavenumber range of interest. Work supported in part by the US Department of Energy under DE-FG02-94ER54235, DE-FC02-04ER54698, and DE-FC02-99ER54512.

  1. Space Shuttle Projects

    NASA Image and Video Library

    2002-03-03

    The Hubble Space Telescope (HST), with its normal routine temporarily interrupted, is about to be captured by the Space Shuttle Columbia prior to a week of servicing and upgrading by the STS-109 crew. The telescope was captured by the shuttle's Remote Manipulator System (RMS) robotic arm and secured on a work stand in Columbia's payload bay where 4 of the 7-member crew performed 5 space walks completing system upgrades to the HST. Included in those upgrades were: The replacement of the solar array panels; replacement of the power control unit (PCU); replacement of the Faint Object Camera (FOC) with a new advanced camera for Surveys (ACS); and installation of the experimental cooling system for the Hubble's Near-Infrared Camera and Multi-object Spectrometer (NICMOS), which had been dormant since January 1999 when its original coolant ran out. The Marshall Space Flight Center had the responsibility for the design, development, and construction of the the HST, which is the most complex and sensitive optical telescope ever made, to study the cosmos from a low-Earth orbit. Launched March 1, 2002, the STS-109 HST servicing mission lasted 10 days, 22 hours, and 11 minutes. It was the 108th flight overall in NASA's Space Shuttle Program.

  2. RBDMS, FracFocus, and Gateway Initiatives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yates, Dan

    Award DE-FE-0000880 from the Department of Energy to the Ground Water Protection Council (GWPC) focuses on state and federal priorities in the areas of state RBDMS development, connectivity between state systems and FracFocus.org, and data sharing initiatives across agencies. The overarching goals of these projects are to: - upgrade the Risk Based Data Management System (RBDMS) to a web based application; - upgrade the RBDMS user interface to make it more intuitive and easier to use - increase connectivity between state RBDMS systems and FracFocus; - provide outreach to states and agencies through training programs, special meetings, and state bymore » state outreach on all deliverables; - provide greater functionality for non-IT users; - update and install RBDMS modules in additional state programs (IL, CA, WY, WV); and; - help make data access more transparent. The primary objective is to enhance the Risk Based Data Management System (RBDMS) by adding new components relevant to current environmental topics such as hydraulic fracturing, increasing field inspection capabilities, creating linkages between FracFocus and state programs, upgrading eForm capabilities, and analyzing potential for data sharing. The GWPC will work with state agencies to develop an RBDMS module(s) that meets these needs.« less

  3. Diagnostic and Hardware Upgrades for the US-PRC PMI Collaboration on EAST

    NASA Astrophysics Data System (ADS)

    Tritz, Kevin; Maingi, R.; Andruczyk, D.; Canik, J.; Wang, Z.; Wirth, B.; Zinkle, S.; Woller, K.; Hu, J. S.; Luo, G. N.; Gong, X. Z.; EAST Team

    2017-10-01

    Several collaborative diagnostic and hardware upgrades are planned to improve understanding and control of Plasma-Material Interactions on EAST, as part of the US-PRC PMI collaboration. Dual-band thermography adapters, designed by UT-K and ORNL, are being designed for existing IR cameras to improve the accuracy of the divertor heat flux measurements by reducing sensitivity to surface emissivity. These measurements should improve power accounting for EAST discharges, which can show a large gap between input power and divertor exhaust power. MIT is preparing tungsten tiles with fluorine depth markers to measure net erosion of PFC tiles. JHU plans to improve the electronics of the Multi-Energy Soft X-ray diagnostic as well as expand the present edge system to a full core-edge measurement; this will enhance the assessment of the effect of Li injection on tungsten accumulation and transport. In addition to PPPL-developed upgrades to the lithium granule and pellet delivery systems, LANL is assessing core-shell micropellets for pellet ablation analysis. Finally, UIUC and PPPL are developing flowing liquid lithium limiters, both with and without LiMIT tile features, for deployment on EAST. Work supported by DoE award DE-SC0016553.

  4. New Outreach Initiatives at the Princeton Plasma Physics Laboratory

    NASA Astrophysics Data System (ADS)

    Zwicker, Andrew; Dominguez, Arturo; Greco, Shannon; Ortiz, Deedee; Delooper, John

    2015-11-01

    In FY15, PPPL concentrated its efforts on a portfolio of outreach activities centered around plasma science and fusion energy that have the potential to reach a large audience and have a significant and measurable impact. The overall goal of these outreach activities is to expose the public (within New Jersey, the US and the world) to the Department of Energy's scientific endeavors and specifically to PPPL's research regarding fusion and plasma science. The projects include several new activities along with upgrades to existing ones. The new activities include the development of outreach demos for the plasma physics community and the upgrade of the Internet Plasma Physics Experience (IPPEX). Our first plasma demo is a low cost DC glow discharge, suitable for tours as well as for student laboratories (plasma breakdown, spectroscopy, probes). This has been field tested in a variety of classes and events. The upgrade to the IPPEX web site includes a new template and a new interactive virtual tokamak. Future work on IPPEX will provide users limited access to data from NSTX-U. Finally, our Young Women's Conference was expanded and improved. These and other new outreach activities will be presented.

  5. Building America Case Study: Trade-Friendly Retrofit Insulated Panels for Existing Buildings, Albany, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    This project evaluated the effectiveness and affordability of integrating retrofit insulated panels into a re-siding project. The Partnership for Home Innovation (PHI) teamed with New York State Energy Research and Development Authority (NYSERDA), the Albany Housing Authority (AHA), and the New York State Weatherization Assistance Program (WAP) administered by Albany Community Action Partnership to demonstrate an energy retrofit and siding upgrade on a two-story, seven unit, multifamily building in Albany New York (CZ 5). The project focused on accomplishing three goals - doubling the existing wall thermal resistance (from approximately R-13 to a weighted average of R-27), reduction of buildingmore » air leakage, and completion of the retrofit within a budget where the additional cost for upgrading wall's thermal resistance is equal to the cost of the standard re-siding effort (i.e., the total cost of the energy efficient re-siding scope of work is not more than double the cost of the standard re-siding effort). Lessons learned from the project strongly indicate that the retrofit panel technology can be installed using common installation practices and with minimal training. Other lessons learned include limitation on the use of standard air sealing materials during cold weather installations and the need to develop better installation guidance for trades working with the level of tolerances that may be present in the existing structure. This technology demonstration showed that exterior retrofit panels provide a viable and reasonable option for the siding trades to increase market opportunities and achieve synergistic benefits for aesthetic upgrades to a building's exterior.« less

  6. Measuring bio-oil upgrade intermediates and corrosive species with polarity-matched analytical approaches

    DOE PAGES

    Connatser, Raynella M.; Lewis, Sr., Samuel Arthur; Keiser, James R.; ...

    2014-10-03

    Integrating biofuels with conventional petroleum products requires improvements in processing to increase blendability with existing fuels. This work demonstrates analysis techniques for more hydrophilic bio-oil liquids that give improved quantitative and qualitative description of the total acid content and organic acid profiles. To protect infrastructure from damage and reduce the cost associated with upgrading, accurate determination of acid content and representative chemical compound analysis are central imperatives to assessing both the corrosivity and the progress toward removing oxygen and acidity in processed biomass liquids. Established techniques form an ample basis for bio-liquids evaluation. However, early in the upgrading process, themore » unique physical phases and varied hydrophilicity of many pyrolysis liquids can render analytical methods originally designed for use in petroleum-derived oils inadequate. In this work, the water solubility of the organic acids present in bio-oils is exploited in a novel extraction and titration technique followed by analysis on the water-based capillary electrophoresis (CE) platform. The modification of ASTM D664, the standard for Total Acid Number (TAN), to include aqueous carrier solvents improves the utility of that approach for quantifying acid content in hydrophilic bio-oils. Termed AMTAN (modified Total Acid Number), this technique offers 1.2% relative standard deviation and dynamic range comparable to the conventional ASTM method. Furthermore, the results of corrosion product evaluations using several different sources of real bio-oil are discussed in the context of the unique AMTAN and CE analytical approaches developed to facilitate those measurements.« less

  7. Resource Management Strategy in the French Navy

    DTIC Science & Technology

    1991-06-01

    central question is whether the French Navy will be able to both upgrade an ageing fleet, and man that projected new fleet with qualified personnel...figures are given in French francs and the dollar equivalent, using an exchange rate of 5.5 francs per dollar. In the most general terms, this thesis...hours worked. The other 240 million francs ($43.6 million) includes projected DCN work hours and the cost of outfitting the ship (i.e. radars, guns

  8. Multiple Award, Multiple Order Contracts - The Future of Navy Surface Maintenance Procurement

    DTIC Science & Technology

    2015-06-01

    example, in October 2004, Australia’s North West Shelf Shipping signed a long-term maintenance and upgrade contract for its fleet of liquefied natural ...fuel tank during shipyard corrosion control activities (e.g., grinding and/or sanding) and there was already a work item in the contract for crack...is not related to items in the original contract. An example of new work is adding fuel tank repair to a combat systems equipment-specific

  9. 76 FR 51369 - Meeting of the National Biodefense Science Board

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-18

    ... future chemical, biological, nuclear, and radiological agents, whether naturally occurring, accidental... of the NBSB's Anthrax Vaccine Working Group. Subsequent agenda topics will be added as priorities...

  10. Assessing potential radiological harm to fukushima recovery workers.

    PubMed

    Scott, Bobby R

    2011-01-01

    A radiological emergency exists at the Fukushima Daiichi (Fukushima I) nuclear power plant in Japan as a result of the March 11, 2011 magnitude 9.0 earthquake and the massive tsunami that arrived later. News media misinformation related to the emergency triggered enormous social fear worldwide of the radioactivity that is being released from damaged fuel rods. The heroic recovery workers are a major concern because they are being exposed to mostly gamma radiation during their work shifts and life-threatening damage to the radiosensitive bone marrow could occur over time. This paper presents a way in which the bone marrow equivalent dose (in millisieverts), as estimated per work shift, could be used along with the hazard function model previously developed for radiological risk assessment to repeatedly check for potential life-threatening harm (hematopoietic system damage) to workers. Three categories of radiation hazard indication are proposed: 1, life-threatening damage unlikely; 2, life-threatening damage possible; 3, life-threatening damage likely. Categories 2 and 3 would be avoided if the whole body effective dose did not exceed the annual effective dose limit of 250 mSv. For down-wind populations, hormetic effects (activated natural protective processes) are much more likely than are deleterious effects.

  11. A radiology department intranet: development and applications.

    PubMed

    Willing, S J; Berland, L L

    1999-01-01

    An intranet is a "private Internet" that uses the protocols of the World Wide Web to share information resources within a company or with the company's business partners and clients. The hardware requirements for an intranet begin with a dedicated Web server permanently connected to the departmental network. The heart of a Web server is the hypertext transfer protocol (HTTP) service, which receives a page request from a client's browser and transmits the page back to the client. Although knowledge of hypertext markup language (HTML) is not essential for authoring a Web page, a working familiarity with HTML is useful, as is knowledge of programming and database management. Security can be ensured by using scripts to write information in hidden fields or by means of "cookies." Interfacing databases and database management systems with the Web server and conforming the user interface to HTML syntax can be achieved by means of the common gateway interface (CGI), Active Server Pages (ASP), or other methods. An intranet in a radiology department could include the following types of content: on-call schedules, work schedules and a calendar, a personnel directory, resident resources, memorandums and discussion groups, software for a radiology information system, and databases.

  12. Assessing the initial adaptability and impact of a mobile dictation and reporting system in the radiology department of an academic hospital

    NASA Astrophysics Data System (ADS)

    Gali, Raja L.; Dave, Jaydev K.

    2017-03-01

    Mobile Radiologist 360, rolled out as part of the voice dictation system upgrade from Nuance Powerscribe 5.0 to PS360 allows an attending radiologist to edit and sign-off a report assigned by a trainee or that has been started by the radiologist on a workstation. The purpose of this study was to evaluate the adoptability and impact of this application. Report turnaround time data was extracted from the RIS (GE-Centricity RIS-IC) for 60 days before- (period-1) and 60 days after- (period-2) the application implementation and then, for 60 days after end of period-2 (period-3). Adoptability of the application was evaluated using two metrics; first, the number of attending radiologists who signed-off reports using the application in periods 2 and 3, and second, the proportion of reports signed-off by the top five users of the mobile application using the application. Impact of the application was evaluated by comparing the time from initial dictation to final sign-off (time_PF) for the top five users of the mobile application to the time_PF by other five radiologists who did not use the application. 41% radiologists used the mobile application at least once during the study period; the proportion of cases signed-off using the mobile application ranged from 1% to 20%. ANOVA revealed no statistically significant effect of the mobile application system on time_PF (p=0.842). In conclusion, there was low initial adoptability and no impact of the mobile dictation and reporting system in reducing the time from initial dictation to final sign-off on a radiology report.

  13. The upgrade of the H.E.S.S. cameras

    NASA Astrophysics Data System (ADS)

    Giavitto, Gianluca; Ashton, Terry; Balzer, Arnim; Berge, David; Brun, Francois; Chaminade, Thomas; Delagnes, Eric; Fontaine, Gerard; Füßling, Matthias; Giebels, Berrie; Glicenstein, Jean-Francois; Gräber, Tobias; Hinton, Jim; Jahnke, Albert; Klepser, Stefan; Kossatz, Marko; Kretzschmann, Axel; Lefranc, Valentin; Leich, Holger; Lüdecke, Hartmut; Lypova, Iryna; Manigot, Pascal; Marandon, Vincent; Moulin, Emmanuel; Naurois, Mathieu de; Nayman, Patrick; Ohm, Stefan; Penno, Marek; Ross, Duncan; Salek, David; Schade, Markus; Schwab, Thomas; Simoni, Rachel; Stegmann, Christian; Steppa, Constantin; Thornhill, Julian; Toussnel, Francois

    2017-12-01

    The High Energy Stereoscopic System (HESS) is an array of imaging atmospheric Cherenkov telescopes (IACTs) located in the Khomas highland in Namibia. It was built to detect Very High Energy (VHE > 100 GeV) cosmic gamma rays. Since 2003, HESS has discovered the majority of the known astrophysical VHE gamma-ray sources, opening a new observational window on the extreme non-thermal processes at work in our universe. HESS consists of four 12-m diameter Cherenkov telescopes (CT1-4), which started data taking in 2002, and a larger 28-m telescope (CT5), built in 2012, which lowers the energy threshold of the array to 30 GeV . The cameras of CT1-4 are currently undergoing an extensive upgrade, with the goals of reducing their failure rate, reducing their readout dead time and improving the overall performance of the array. The entire camera electronics has been renewed from ground-up, as well as the power, ventilation and pneumatics systems, and the control and data acquisition software. Only the PMTs and their HV supplies have been kept from the original cameras. Novel technical solutions have been introduced, which will find their way into some of the Cherenkov cameras foreseen for the next-generation Cherenkov Telescope Array (CTA) observatory. In particular, the camera readout system is the first large-scale system based on the analog memory chip NECTAr, which was designed for CTA cameras. The camera control subsystems and the control software framework also pursue an innovative design, exploiting cutting-edge hardware and software solutions which excel in performance, robustness and flexibility. The CT1 camera has been upgraded in July 2015 and is currently taking data; CT2-4 have been upgraded in fall 2016. Together they will assure continuous operation of HESS at its full sensitivity until and possibly beyond the advent of CTA. This contribution describes the design, the testing and the in-lab and on-site performance of all components of the newly upgraded HESS camera.

  14. Integrating Learner-Driven and Organization-Driven Agendas: A Workplace Study.

    ERIC Educational Resources Information Center

    Lessard, Richard

    For the past 4 years, Alpena Community College (ACC) in Michigan has been involved in the Workplace Partnership Project (WPP), a federally funded program which brings basic skills classes into the worksite to help upgrade employees' math, reading, writing, problem-solving, and science knowledge. The college works with partner companies to help…

  15. Building the Capacity of School Leaders and Teachers to Implement Reform at All Levels

    ERIC Educational Resources Information Center

    Southern Regional Education Board (SREB), 2010

    2010-01-01

    Leaders of successful high schools, middle grades schools and technology centers are strengthening their skills and involving the entire school in plans to raise student achievement. The best school leaders establish an environment of continuous progress in which teachers and leaders work together to upgrade curriculum and instruction, examine…

  16. 20 CFR 668.500 - What services may INA grantees provide to or for employers under section 166?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-employment training; (4) Customized training; (5) On-the-Job training (OJT); (6) Post-employment services, including training and support services to encourage job retention and upgrading; (7) Work experience for... participants, including job restructuring services; (2) Recruitment and assessment of potential employees, with...

  17. Seat belt use, especially among low-use drivers, increases as Florida upgrades to primary seat belt enforcement : traffic tech.

    DOT National Transportation Integrated Search

    2012-08-01

    As a secondary seat belt law State, Florida had worked : for many years to encourage more drivers to wear : their seat belts by participating in annual Click It or : Ticket (CIOT) mobilizations, and by conducting special : programs in rural areas of ...

  18. Existing Whole-House Solutions Case Study: Habitat for Humanity of Palm Beach County, Lake Worth, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2012-03-01

    PNNL and Florida Solar Energy Center worked with Habitat for Humanity of Palm Beach County to upgrade an empty 1996 home with a 14.5 SEER AC, heat pump water heater, CFLs, more attic insulation, and air sealing to cut utility bills $872 annually.

  19. A Suggested In-Service Training Model Based on Turkish Preschool Teachers' Conceptions for Sustainable Development

    ERIC Educational Resources Information Center

    Kabadayi, Abdulkadir

    2016-01-01

    Nowadays, teacher professionalization has been upgrading and the status, training and working conditions of teachers have received a great deal of interest for sustainable education. It is recognized that if teachers are equipped with adequate professional knowledge and personal practical knowledge, they will become active curriculum planners at…

  20. Paying for Itself

    ERIC Educational Resources Information Center

    Wilkinson, Ron

    2009-01-01

    Many schools and universities want the U.S. Green Building Council's LEED certification for their facilities, but they are concerned about cost. This certification is tangible evidence that a facility is designed to conserve resources and use energy more efficiently. "Low-cost/no-cost" upgrades can be worked into a capital plan that provides a 3-…

  1. What Facilitates and Impedes Collaborative Work during Higher Education Software Implementation Projects?

    ERIC Educational Resources Information Center

    Cramer, Sharon F.; Tetewsky, Sheldon J.; Marczynski, Kelly S.

    2010-01-01

    Implementations of new or major upgrades of existing student information systems require incorporation of new paradigms and the exchange of familiar routines for new methods. As a result, implementations are almost always time consuming and expensive. Many people in the field of information technology have identified some of the challenges faced…

  2. Reference News Release:Southern Coal Corporation to Make System-Wide Upgrades to Reduce Water Pollution from Mining Operations in Appalachia

    EPA Pesticide Factsheets

    The settlement also requires the establishment of a $4.5 million letter of credit and a standby trust that will guarantee sufficient funding for, and a mechanism to accomplish, compliance with the Clean Water Act and the work the companies.

  3. Technology Counts 2013: Building the Digital District

    ERIC Educational Resources Information Center

    Education Week, 2013

    2013-01-01

    Schools are working to incorporate more multimedia into classrooms, upgrade online professional development, and do a better job using data to improve student achievement. Even though nearly every school in the country is now connected to the Internet, not all of them have the kind of connections that allow teachers and students to make full use…

  4. What Is a Day's Work? A Personnel Practices Guide for Household Employees and Employers.

    ERIC Educational Resources Information Center

    Bowen, Uvelia S. A.

    The guide presents the policies of the Household Employment Association for Reevaluation and Training (HEART) for upgrading the status of household employment. An overview is given of the association's methods of recruitment, training (in its licensed, private trade school), community education, job development, and post-placement counseling. The…

  5. Due Processors: Educators Seek a Digital Upgrade for Teaching Law

    ERIC Educational Resources Information Center

    Monaghan, Peter

    2008-01-01

    In 1871, Christopher Columbus Langdell, a prominent jurist who had joined the law faculty at Harvard University, hit on the idea of compiling thick, imposing "casebooks" with hundreds of appeals-court rulings on particular areas of law--contracts, constitutional law, torts, and others. Today, the hefty tomes and related works have become the…

  6. Lifelong Learning: Proceedings of a Symposium. 16 May 2002

    ERIC Educational Resources Information Center

    Selby Smith, Chris, Ed.; Ferrier, Fran, Ed.

    2003-01-01

    The Educational Research Centre for the Economics of Education and Training (CEET) conducted a survey focusing on lifelong learning and the world of work, particularly on the need for retraining and upgrading of skills and knowledge. The survey involved five different approaches: surveys of the available quantitative and qualitative material; a…

  7. Indexing Anatomical Phrases in Neuro-Radiology Reports to the UMLS 2005AA

    PubMed Central

    Bashyam, Vijayaraghavan; Taira, Ricky K.

    2005-01-01

    This work describes a methodology to index anatomical phrases to the 2005AA release of the Unified Medical Language System (UMLS). A phrase chunking tool based on Natural Language Processing (NLP) was developed to identify semantically coherent phrases within medical reports. Using this phrase chunker, a set of 2,551 unique anatomical phrases was extracted from brain radiology reports. These phrases were mapped to the 2005AA release of the UMLS using a vector space model. Precision for the task of indexing unique phrases was 0.87. PMID:16778995

  8. Radiological Defense. Volume 4. An Introduction to Radiological Instruments for Military Use

    DTIC Science & Technology

    1950-01-01

    alpha admission. Thin mica and stretched nylon walls with nonmetals of low atomic number and and rubber hydrochloride films about 5 microns writing...individual pulse. This process is called qu •,cIh1ng and can be ac- R, 5ME.OH, , • .. complished by using external electronic methods ’-""::_:-:Ž-:- " or...counter tubes field survey work. Mica windows down to 0.5 )resentliy employed in survey meters are " inch in mg/cm 2 are available, although in normal

  9. An active pixel sensor to detect diffused X-ray during Interventional Radiology procedure

    NASA Astrophysics Data System (ADS)

    Servoli, L.; Battisti, D.; Biasini, M.; Checcucci, B.; Conti, E.; Di Lorenzo, R.; Esposito, A.; Fanò, L.; Paolucci, M.; Passeri, D.; Pentiricci, A.; Placidi, P.

    2012-04-01

    Interventional radiologists and staff members are frequently exposed to protracted and fractionated low doses of ionizing radiation due to diffused X-ray radiation. The authors propose a novel approach to monitor on line staff during their interventions by using a device based on an Active Pixel Sensor developed for tracking applications. Two different photodiode configurations have been tested in standard Interventional Radiology working conditions. Both options have demonstrated the capability to measure the photon flux and the energy flux to a sufficient degree of uncertainty.

  10. Vibrational spectroscopy with neutrons: Recent developments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Stewart F.; Ramirez-Cuesta, Anibal J.; Daemen, Luke L.

    Here in this short review, we will briefly summarise the differences between INS spectroscopy and conventional infrared and Raman spectroscopies. We will illustrate these with the current state-of-the art, using C 70 as an example. The main focus of the article will be on the key advances in INS spectroscopy over the last ten years or so, that are driving new areas of research. The developments fall into three broad categories: (i) new sources, (ii) new and/or upgraded instrumentation and (iii) novel uses for existing instruments. For (i) we summarise the new neutron sources that are now, or will be,more » operating. For (ii) we show the capabilities of new or upgraded instruments. These offer unprecedented levels of sensitivity: sub-millimole quantities of hydrogen can be measured and millimole quantities of low cross section materials. Recent work on hexahalo metallates and adsorbed CO 2 is used to demonstrate what is now feasible. For (iii), instruments that were designed for studies of magnetism, are now being used for molecular spectroscopy, especially for catalysts. This is illustrated with work on CuH and methanol synthesis catalysts.« less

  11. Vibrational spectroscopy with neutrons: Recent developments

    DOE PAGES

    Parker, Stewart F.; Ramirez-Cuesta, Anibal J.; Daemen, Luke L.

    2017-09-21

    Here in this short review, we will briefly summarise the differences between INS spectroscopy and conventional infrared and Raman spectroscopies. We will illustrate these with the current state-of-the art, using C 70 as an example. The main focus of the article will be on the key advances in INS spectroscopy over the last ten years or so, that are driving new areas of research. The developments fall into three broad categories: (i) new sources, (ii) new and/or upgraded instrumentation and (iii) novel uses for existing instruments. For (i) we summarise the new neutron sources that are now, or will be,more » operating. For (ii) we show the capabilities of new or upgraded instruments. These offer unprecedented levels of sensitivity: sub-millimole quantities of hydrogen can be measured and millimole quantities of low cross section materials. Recent work on hexahalo metallates and adsorbed CO 2 is used to demonstrate what is now feasible. For (iii), instruments that were designed for studies of magnetism, are now being used for molecular spectroscopy, especially for catalysts. This is illustrated with work on CuH and methanol synthesis catalysts.« less

  12. Vibrational spectroscopy with neutrons: Recent developments

    NASA Astrophysics Data System (ADS)

    Parker, Stewart F.; Ramirez-Cuesta, Anibal J.; Daemen, Luke

    2018-02-01

    In this short review, we will briefly summarise the differences between INS spectroscopy and conventional infrared and Raman spectroscopies. We will illustrate these with the current state-of-the art, using C70 as an example. The main focus of the article will be on the key advances in INS spectroscopy over the last ten years or so, that are driving new areas of research. The developments fall into three broad categories: (i) new sources, (ii) new and/or upgraded instrumentation and (iii) novel uses for existing instruments. For (i) we summarise the new neutron sources that are now, or will be, operating. For (ii) we show the capabilities of new or upgraded instruments. These offer unprecedented levels of sensitivity: sub-millimole quantities of hydrogen can be measured and millimole quantities of low cross section materials. Recent work on hexahalo metallates and adsorbed CO2 is used to demonstrate what is now feasible. For (iii), instruments that were designed for studies of magnetism, are now being used for molecular spectroscopy, especially for catalysts. This is illustrated with work on CuH and methanol synthesis catalysts.

  13. Incidence, predictors, and procedural results of upgrade to resynchronization therapy: the RAFT upgrade substudy.

    PubMed

    Essebag, Vidal; Joza, Jacqueline; Birnie, David H; Sapp, John L; Sterns, Laurence D; Philippon, Francois; Yee, Raymond; Crystal, Eugene; Kus, Teresa; Rinne, Claus; Healey, Jeffrey S; Sami, Magdi; Thibault, Bernard; Exner, Derek V; Coutu, Benoit; Simpson, Chris S; Wulffhart, Zaev; Yetisir, Elizabeth; Wells, George; Tang, Anthony S L

    2015-02-01

    The resynchronization-defibrillation for ambulatory heart failure trial (RAFT) study demonstrated that adding cardiac resynchronization therapy (CRT) in selected patients requiring de novo implantable cardiac defibrillators (ICD) reduced mortality as compared with ICD therapy alone, despite an increase in procedure-related adverse events. Data are lacking regarding the management of patients with ICD therapy who develop an indication for CRT upgrade. Participating RAFT centers provided data regarding de novo CRT-D (CRT with ICD) implant, upgrade to CRT-D during RAFT (study upgrade), and upgrade within 6 months after presentation of study results (substudy). Substudy centers enrolled 1346 (74.9%) patients in RAFT, including 644 de novo, 80 study upgrade, and 60 substudy CRT attempts. The success rate (initial plus repeat attempts) was 95.2% for de novo versus 96.3% for study upgrade and 90.0% for substudy CRT attempts (P=0.402). Acute complications occurred among 26.2% of de novo versus 18.8% of study upgrade and 3.4% of substudy CRT implantation attempts (P<0.001). The most common complication was left ventricular lead dislodgement. The principal reasons for not yet attempting upgrade in the substudy were patient preference (31.9%), New York Heart Association Class I (17.0%), and a QRS<150 ms (13.1%). Among a broad group of implant physicians, CRT upgrades were performed in patients with an ICD in situ with no difference in implant success rate and a reduced acute complication rate as compared with a de novo CRT implant. Decisions to upgrade were influenced by predictors of benefit in subgroup analyses of the RAFT study and other trials. © 2014 American Heart Association, Inc.

  14. Herbert M. Parker: Publications and other contributions to radiological and health physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kathren, R.L.; Baalman, R.W.; Bair, W.J.

    For more than a half century, Herbert M. Parker was a leading force in radiological physics. This book brings together all of Parker's published and unpublished papers and is divided into six parts. The second edition is on his work in medical physics. The third part is on his contribution to the evolution of radiological units. The fourth and largest portion of the book is on radiation protection: the Manhattan Project and beyond. There are no less than 31 subsections to this part of the book, and it includes: possible hazards of repeated fluoroscopy in infants, health protection, health physicsmore » implementation and radiation protection, radiation protection in the atomic energy industry, radiation exposure from environmental hazards, personnel dosimetry for radiation accidents, and an article on the dilemma of lung dosimetry.« less

  15. Paradigms of perception in clinical practice.

    PubMed

    Jacobson, Francine L; Berlanstein, Bruce P; Andriole, Katherine P

    2006-06-01

    Display strategies for medical images in radiology have evolved in tandem with the technology by which images are made. The close of the 20th century, nearly coincident with the 100th anniversary of the discovery of x-rays, brought radiologists to a new crossroad in the evolution of image display. The increasing availability, speed, and flexibility of computer technology can now revolutionize how images are viewed and interpreted. Radiologists are not yet in agreement regarding the next paradigm for image display. The possibilities are being explored systematically through the Society for Computer Applications in Radiology's Transforming the Radiological Interpretation Process initiative. The varied input of radiologists who work in a large variety of settings will enable new display strategies to best serve radiologists in the detection and quantification of disease. Considerations and possibilities for the future are presented in this paper.

  16. [Ergonomics of the workplace in radiology].

    PubMed

    García-Lallana, A; Viteri-Ramírez, G; Saiz-Mendiguren, R; Broncano, J; Dámaso Aquerreta, J

    2011-01-01

    The replacement of conventional films and view boxes with digital images and computer monitors managed by PACS has clearly improved the diagnostic imaging workplace. The new setup has many advantages, including increased productivity brought about by decreased overall time required for image interpretation. On the other hand, the implementation of the digital workplace has increased the importance of factors like background lighting and the position of the chair, work table, mouse, keyboard, and monitor to prevent lesions that can disable the radiologist. The influence of these factors is often undervalued in the design and implementation of the radiological workplace. This article provides recommendations for the design of the radiological workplace based on ergonomics, which is the science that studies interactions among humans and other elements of a system. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  17. Work-Related Injuries of Radiologists and Possible Ergonomic Solutions: Recommendations From the ACR Commission on Human Resources.

    PubMed

    Sze, Gordon; Bluth, Edward I; Bender, Claire E; Parikh, Jay R

    2017-10-01

    Increasingly, radiologists' workplaces revolve around PACS and digital imaging. Use of these technologies can lead to repetitive strain injuries, many of which can be exacerbated by specific features of a radiology practice environment. Ergonomic approaches, such as proper reading room structure, lighting, temperature, noise, and equipment setup, can help decrease the frequency and severity of repetitive strain injuries and improve radiologist productivity. However, ergonomic approaches are complex, include all aspects of the radiology practice environment, and are best implemented along with proper training of the practicing radiologists. The ergonomic approaches considered most important by members of the ACR Commission on Human Resources are presented in this report, and this information may serve as an aid in departmental planning. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  18. Environmental monitoring in interventional radiology

    NASA Astrophysics Data System (ADS)

    Del Sol, S.; Garcia, R.; Sánchez-Guzmán, D.; Ramirez, G.; Chavarin, E. U.; Rivera, T.

    2017-01-01

    The procedures in Interventional Radiology involve long times of exposure and high number of radiographic images that bring higher radiation doses to patients, staff and environmental than those received in conventional Radiology. Currently for monitoring the dose, the thermoluminescent dosimetry use is recommended. The aim of this work was to carry out the monitoring of the environmental scattered radiation inside the IR room using two types of thermoluminescent dosimeters, TLD-100 (reference dosimeter), CaSO4:Dy (synthesized in our laboratory). The results indicate that the TLD-100 is not effective for the environmental monitoring of low-energy Rx rooms. The CaSO4:Dy presented good behaviour over the 6 months of study. The results will be specific to each room so it is recommended such studies as part of the program of quality control of each Rx room.

  19. A poloidal section neutron camera for MAST upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sangaroon, S.; Weiszflog, M.; Cecconello, M.

    2014-08-21

    The Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade) is intended as a demonstration of the physics viability of the Spherical Tokamak (ST) concept and as a platform for contributing to ITER/DEMO physics. Concerning physics exploitation, MAST Upgrade plasma scenarios can contribute to the ITER Tokamak physics particularly in the field of fast particle behavior and current drive studies. At present, MAST is equipped with a prototype neutron camera (NC). On the basis of the experience and results from previous experimental campaigns using the NC, the conceptual design of a neutron camera upgrade (NC Upgrade) is being developed. As part ofmore » the MAST Upgrade, the NC Upgrade is considered a high priority diagnostic since it would allow studies in the field of fast ions and current drive with good temporal and spatial resolution. In this paper, we explore an optional design with the camera array viewing the poloidal section of the plasma from different directions.« less

  20. [PACS: storage and retrieval of digital radiological image data].

    PubMed

    Wirth, S; Treitl, M; Villain, S; Lucke, A; Nissen-Meyer, S; Mittermaier, I; Pfeifer, K-J; Reiser, M

    2005-08-01

    Efficient handling of both picture archiving and retrieval is a crucial factor when new PACS installations as well as technical upgrades are planned. For a large PACS installation for 200 actual studies, the number, modality,and body region of available priors were evaluated. In addition, image access time of 100 CT studies from hard disk (RAID), magneto-optic disk (MOD), and tape archives (TAPE) were accessed. For current examinations priors existed in 61.1% with an averaged quantity of 7.7 studies. Thereof 56.3% were within 0-3 months, 84.9% within 12 months, 91.7% within 24 months, and 96.2% within 36 months. On average, access to images from the hard disk cache was more than 100 times faster then from MOD or TAPE. Since only PACS RAID provides online image access, at least current imaging of the past 12 months should be available from cache. An accurate prefetching mechanism facilitates effective use of the expensive online cache area. For that, however, close interaction of PACS, RIS, and KIS is an indispensable prerequisite.

  1. Hybrid emergency radiation detection: a wireless sensor network application for consequence management of a radiological release

    NASA Astrophysics Data System (ADS)

    Kyker, Ronald D.; Berry, Nina; Stark, Doug; Nachtigal, Noel; Kershaw, Chris

    2004-08-01

    The Hybrid Emergency Radiation Detection (HERD) system is a rapidly deployable ad-hoc wireless sensor network for monitoring the radiation hazard associated with a radiation release. The system is designed for low power, small size, low cost, and rapid deployment in order to provide early notification and minimize exposure. The many design tradeoffs, decisions, and challenges in the implementation of this wireless sensor network design will be presented and compared to the commercial systems available. Our research in a scaleable modular architectural highlights the need and implementation of a system level approach that provides flexibility and adaptability for a variety of applications. This approach seeks to minimize power, provide mission specific specialization, and provide the capability to upgrade the system with the most recent technology advancements by encapsulation and modularity. The implementation of a low power, widely available Real Time Operating System (RTOS) for multitasking with an improvement in code maintenance, portability, and reuse will be presented. Finally future design enhancements technology trends affecting wireless sensor networks will be presented.

  2. Slum Upgrading and Health Equity.

    PubMed

    Corburn, Jason; Sverdlik, Alice

    2017-03-24

    Informal settlement upgrading is widely recognized for enhancing shelter and promoting economic development, yet its potential to improve health equity is usually overlooked. Almost one in seven people on the planet are expected to reside in urban informal settlements, or slums, by 2030. Slum upgrading is the process of delivering place-based environmental and social improvements to the urban poor, including land tenure, housing, infrastructure, employment, health services and political and social inclusion. The processes and products of slum upgrading can address multiple environmental determinants of health. This paper reviewed urban slum upgrading evaluations from cities across Asia, Africa and Latin America and found that few captured the multiple health benefits of upgrading. With the Sustainable Development Goals (SDGs) focused on improving well-being for billions of city-dwellers, slum upgrading should be viewed as a key strategy to promote health, equitable development and reduce climate change vulnerabilities. We conclude with suggestions for how slum upgrading might more explicitly capture its health benefits, such as through the use of health impact assessment (HIA) and adopting an urban health in all policies (HiAP) framework. Urban slum upgrading must be more explicitly designed, implemented and evaluated to capture its multiple global environmental health benefits.

  3. Slum Upgrading and Health Equity

    PubMed Central

    Corburn, Jason; Sverdlik, Alice

    2017-01-01

    Informal settlement upgrading is widely recognized for enhancing shelter and promoting economic development, yet its potential to improve health equity is usually overlooked. Almost one in seven people on the planet are expected to reside in urban informal settlements, or slums, by 2030. Slum upgrading is the process of delivering place-based environmental and social improvements to the urban poor, including land tenure, housing, infrastructure, employment, health services and political and social inclusion. The processes and products of slum upgrading can address multiple environmental determinants of health. This paper reviewed urban slum upgrading evaluations from cities across Asia, Africa and Latin America and found that few captured the multiple health benefits of upgrading. With the Sustainable Development Goals (SDGs) focused on improving well-being for billions of city-dwellers, slum upgrading should be viewed as a key strategy to promote health, equitable development and reduce climate change vulnerabilities. We conclude with suggestions for how slum upgrading might more explicitly capture its health benefits, such as through the use of health impact assessment (HIA) and adopting an urban health in all policies (HiAP) framework. Urban slum upgrading must be more explicitly designed, implemented and evaluated to capture its multiple global environmental health benefits. PMID:28338613

  4. Catalytic upgrading of bio-oil produced from hydrothermal liquefaction of Nannochloropsis sp.

    PubMed

    Shakya, Rajdeep; Adhikari, Sushil; Mahadevan, Ravishankar; Hassan, El Barbary; Dempster, Thomas A

    2018-03-01

    Upgrading of bio-oil obtained from hydrothermal liquefaction (HTL) of algae is necessary for it to be used as a fuel. In this study, bio-oil obtained from HTL of Nannochloropsis sp. was upgraded using five different catalysts (Ni/C, ZSM-5, Ni/ZSM-5, Ru/C and Pt/C) at 300 °C and 350 °C. The upgraded bio-oil yields were higher at 300 °C; however, higher quality upgraded bio-oils were obtained at 350 °C. Ni/C gave the maximum upgraded bio-oil yield (61 wt%) at 350 °C. However, noble metal catalysts (Ru/C and Pt/C) gave the better upgraded bio-oils in terms of acidity, heating values, and nitrogen values. The higher heating value of the upgraded bio-oils ranged from 40 to 44 MJ/kg, and the nitrogen content decreased from 5.37 to 1.29 wt%. Most of the upgraded bio-oils (35-40 wt%) were in the diesel range. The major components present in the gaseous products were CH 4 , CO, CO 2 and lower alkanes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, Nicholas; Watson, Erica E.; Wright, Kyle A.

    The Global Threat Reduction Initiative (GTRI) reduces and protects vulnerable nuclear and radiological material located at civilian sites worldwide from sabotage, theft or diversion. The GTRI program has worked successfully with foreign countries to remove and protect nuclear and radioactive materials including high-activity sources used in medical, commercial, and research applications. There are many barriers to successful bilateral cooperation that must be overcome including language, preconceived perceptions, long distances, and different views on the threat and protection requirements. Successful cooperation is often based on relationships and building trusting relationships takes time. In the case of Mexico, GTRI first made contactmore » in 2005. The project then lost momentum and stalled. At the same time, GTRI’s cooperation with the Republic of Colombia was a resounding success resulting in the securing of forty sites; the consolidation of numerous disused/orphan sources at a secure national storage facility; and, the development of a comprehensive approach to security including, inter alia, training and sustainability. The government of Colombia also showcased this comprehensive approach to thirteen Central American and Caribbean countries at a GTRI regional security conference held in Panama in October 2004. Representatives from the Colombian government were aware of GTRI’s interest in initiating cooperation with the Government of Mexico and to facilitate this cooperation, they offered to invite their Mexican counterparts to Colombia to observe its successful cooperation with GTRI. Shortly after that visit, the Government of Mexico agreed to move forward and requested that the cooperative efforts in Mexico be performed in a tripartite manner, leveraging the skills, experience, and resources of the Colombians. As a result, 22 of Mexico’s largest radioactive sites have had security upgrades in place within 18 months of cooperation.« less

  6. Conception of a New Recoil Proton Telescope for Real-Time Neutron Spectrometry in Proton-Therapy

    NASA Astrophysics Data System (ADS)

    Combe, Rodolphe; Arbor, Nicolas; el Bitar, Ziad; Higueret, Stéphane; Husson, Daniel

    2018-01-01

    Neutrons are the main type of secondary particles emitted in proton-therapy. Because of the risk of secondary cancer and other late occurring effects, the neutron dose should be included in the out-of-field dose calculations. A neutron spectrometer has to be used to take into account the energy dependence of the neutron radiological weighting factor. Due to its high dependence on various parameters of the irradiation (beam, accelerator, patient), the neutron spectrum should be measured independently for each treatment. The current reference method for the measurement of the neutron energy, the Bonner Sphere System, consists of several homogeneous polyethylene spheres with increasing diameters equipped with a proportional counter. It provides a highresolution reconstruction of the neutron spectrum but requires a time-consuming work of signal deconvolution. New neutron spectrometers are being developed, but the main experimental limitation remains the high neutron flux in proton therapy treatment rooms. A new model of a real-time neutron spectrometer, based on a Recoil Proton Telescope technology, has been developed at the IPHC. It enables a real-time high-rate reconstruction of the neutron spectrum from the measurement of the recoil proton trajectory and energy. A new fast-readout microelectronic integrated sensor, called FastPixN, has been developed for this specific purpose. A first prototype, able to detect neutrons between 5 and 20 MeV, has already been validated for metrology with the AMANDE facility at Cadarache. The geometry of the new Recoil Proton Telescope has been optimized via extensive Geant4 Monte Carlo simulations. Uncertainty sources have been carefully studied in order to improve simultaneously efficiency and energy resolution, and solutions have been found to suppress the various expected backgrounds. We are currently upgrading the prototype for secondary neutron detection in proton therapy applications.

  7. ERATOSTHENES: excellence research Centre for Earth surveillance and space-based monitoring of the environment, the EXCELSIOR Horizon 2020 teaming project

    NASA Astrophysics Data System (ADS)

    Hadjimitsis, Diofantos G.; Kontoes, Haris; Schreier, Gunter; Ansmann, Albert; Komodromos, George; Themistocleous, Kyriacos; Mamouri, Rodanthi; Michaelides, Silas; Nisantzi, Argyro; Papoutsa, Christiana; Neocleous, Kyriacos; Mettas, Christodoulos; Tzouvaras, Marios; Evagorou, Evagoras; Christofe, Andreas; Melillos, George; Papoutsis, Ioannis

    2017-10-01

    The aim of this paper is to present the strategy and vision to upgrade the existing ERATOSTHENES Research Centre (ERC) established within the Cyprus University of Technology (CUT) into a sustainable, viable and autonomous Centre of Excellence (CoE) for Earth Surveillance and Space-Based Monitoring of the Environment, which will provide the highest quality of related services on the National, European and International levels. EXCELSIOR is a Horizon 2020 Teaming project which addresses a specific challenge defined by the work program, namely, the reduction of substantial disparities in the European Union by supporting research and innovation activities and systems in low performing countries. It also aims at establishing long-term and strategic partnerships between the Teaming partners, thus reducing internal research and innovation disparities within European Research and Innovation landscape. The proposed CoE envisions the upgrading of the existing ERC into an inspiring environment for conducting basic and applied research and innovation in the areas of the integrated use of remote sensing and space-based techniques for monitoring the environment. Environment has been recognized by the Smart Specialization Strategy of Cyprus as the first horizontal priority for future growth of the island. The foreseen upgrade will regard the expansion of this vision to systematic monitoring of the environment using Earth Observation, space and ground based integrated technologies. Such an approach will lead to the systematic monitoring of all three domains of the Environment (Air, Land, Water). Five partners have united to upgrade the existing ERC into a CoE, with the common vision to become a world-class innovation, research and education centre, actively contributing to the European Research Area (ERA). More specifically, the Teaming project is a team effort between the Cyprus University of Technology (CUT, acting as the coordinator), the German Aerospace Centre (DLR), the National Observatory of Athens (NOA), the German Leibniz Institute for Tropospheric Research (TROPOS) and the Cyprus Department of Electronic Communications of the Ministry of Transport, Communications and Works (DEC-MTCW).

  8. Bioelectrochemical removal of carbon dioxide (CO2): an innovative method for biogas upgrading.

    PubMed

    Xu, Heng; Wang, Kaijun; Holmes, Dawn E

    2014-12-01

    Innovative methods for biogas upgrading based on biological/in-situ concepts have started to arouse considerable interest. Bioelectrochemical removal of CO2 for biogas upgrading was proposed here and demonstrated in both batch and continuous experiments. The in-situ biogas upgrading system seemed to perform better than the ex-situ one, but CO2 content was kept below 10% in both systems. The in-situ system's performance was further enhanced under continuous operation. Hydrogenotrophic methanogenesis and alkali production with CO2 absorption could be major contributors to biogas upgrading. Molecular studies showed that all the biocathodes associated with biogas upgrading were dominated by sequences most similar to the same hydrogenotrophic methanogen species, Methanobacterium petrolearium (97-99% sequence identity). Conclusively, bioelectrochemical removal of CO2 showed great potential for biogas upgrading. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Heterogeneous catalysis in complex, condensed reaction media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantu, David C.; Wang, Yang-Gang; Yoon, Yeohoon

    Many reactions required for the upgrading of biomass into fuels and chemicals—hydrogenation, hydrodeoxygenation, hydrocracking—are ostensibly similar to those practiced in the upgrading of petroleum into fuels. But, repurposing hydroprocessing catalysts from refinery operations to treat bio-oil has proved to be unsatisfactory. New catalysts are needed because the composition of the biogenic reactants differs from that of petroleum-derived feedstocks (e.g. the low concentration of sulfur in cellulose-derived biomass precludes use of metal sulfide catalysts unless sulfur is added to the reaction stream). New processes are needed because bio-oils oligomerize rapidly, forming intractable coke and “gunk”, at temperatures so low that themore » desired upgrading reactions are impractically slow, and so low that the bio-oil upgrading must be handled as a condensed fluid. Ideally, the new catalysts and processes would exploit the properties of the multiple phases present in condensed bio-oil, notably the polarizability and structure of the fluid near a catalyst’s surface in the cybotactic region. The results of preliminary modeling of the cybotactic region of different catalyst surfaces in the hydrogenation of phenol suggest that Pd catalysts supported on hydrophilic surfaces are more active than catalysts based on lipophilic supports because the former serve to enhance the concentration of the phenol in the vicinity of the Pd. The effect stems from thermodynamics, not the rate of mass transport. This work was supported by the US Department of Energy, Office of Energy Efficiency and Renewable Energy, Bioenergy Technologies Office. Pacific Northwest National Laboratory (PNNL) is a multiprogram national laboratory operated for DOE by Battelle.« less

  10. Extreme Gleason Upgrading From Biopsy to Radical Prostatectomy: A Population-based Analysis.

    PubMed

    Winters, Brian R; Wright, Jonathan L; Holt, Sarah K; Lin, Daniel W; Ellis, William J; Dalkin, Bruce L; Schade, George R

    2016-10-01

    To examine the risk factors associated with the odds of extreme Gleason upgrading at radical prostatectomy (RP) (defined as a Gleason prognostic group score increase of ≥2), we utilized a large, population-based cancer registry. The Surveillance, Epidemiologic, and End Results database was queried (2010-2011) for all patients diagnosed with Gleason 3 + 3 or 3 + 4 on prostate needle biopsy. Available clinicopathologic factors and the odds of upgrading and extreme upgrading at RP were evaluated using multivariate logistic regression. A total of 12,459 patients were identified, with a median age of 61 (interquartile range: 56-65) and a diagnostic prostate-specific antigen (PSA) of 5.5 ng/mL (interquartile range: 4.3-7.5). Upgrading was observed in 34% of men, including 44% of 7402 patients with Gleason 3 + 3 and 19% of 5057 patients with Gleason 3 + 4 disease. Age, clinical stage, diagnostic PSA, and % prostate needle biopsy cores positive were independently associated with odds of any upgrading at RP. In baseline Gleason 3 + 3 disease, extreme upgrading was observed in 6%, with increasing age, diagnostic PSA, and >50% core positivity associated with increased odds. In baseline Gleason 3 + 4 disease, extreme upgrading was observed in 4%, with diagnostic PSA and palpable disease remaining predictive. Positive surgical margins were significantly higher in patients with extreme upgrading at RP (P < .001). Gleason upgrading at RP is common in this large population-based cohort, including extreme upgrading in a clinically significant portion. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Flattening the organization: implementing self-directed work groups.

    PubMed

    Brandon, G M

    1996-01-01

    In response to tremendous growth of managed care and threats to financial stability and job security, the Greater Baltimore Medical Center (GBMC) restructured itself into independent business units. The radiology department at GBMC resolved to reduce cost per unit-of-service, improve service, determine optimal staffing levels and reduce the number of layers of organization. It was decided to achieve those goals by implementing self-directed work groups. Staff buy-in was critical to success of the project. To begin, the staff was educated intensively about current trends in healthcare, managed care and potential changes in the job market. The radiology department was allowed to reduce the size of its staff through attrition and worked hard to focus staff concern on the impact each individual could have on the bottom line and the resultant effect on job security. Self-directed work groups were designed on a matrix that used small "service teams" in combinations to form larger "work groups." Actual work and daily activities occur at the service team level; information exchange and major decisions occue at the work group level. Seventeen months after beginning the project and 10 months after implementation, the organization has flattened, staff members have adjusted well to new roles, there have been no lay-offs, and the matrix system of small and large groups have proved particularly valuable.

  12. Technostress Effect on Task Productivity in Radiologic Healthcare

    ERIC Educational Resources Information Center

    Furniss, Richard D.

    2014-01-01

    Long recognized as a form of maladaptation to Technology in work settings, the Topic of Technostress has garnered attention from numerous researchers in an attempt to both quantify and codify relationships and impact in the work setting. The intention of conducting research on the topic of Technostress was to build upon the current knowledge base…

  13. Personal Branding: A Primer for Radiology Trainees and Radiologists.

    PubMed

    Kalia, Vivek; Patel, Amy K; Moriarity, Andrew K; Canon, Cheri L

    2017-07-01

    A radiologist's personal brand is a composite of many parts in one's professional life. In an age where work quality and digital footprints are tracked and measured more than ever before, it behooves radiologists to develop and curate their own individual brands in effective ways. Personal branding consists of the decisions we make, both consciously and unconsciously, which affect our reputation and the likelihood of seeking our services in the future for both patients and referring providers. As hospital systems are increasingly adjusting their systems to cater to better patient experiences, it is imperative that radiologists similarly adjust our practice patterns to accommodate the needs of the new paradigm of value-based care. It is no longer sufficient to only practice excellent clinical radiology; one's service experience to clinical providers, report quality, and digital presence must all be robust and compelling. Defining your brand and promoting your vision and quality standards have become as important to radiologists' future as keeping up with advancements in radiologic technology. One must select the proper platforms and types of interactions in which to engage from available social media options. Developing a consistent brand and presence in the work setting, on social media accounts, and in professional organizations at the local, national, and international levels is the ultimate goal. At present, very little, if any, formal training is provided on personal branding skills such as these in current residency curricula, and it is critical for radiologists to fill their gaps in knowledge through additional means. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  14. Proceedings of the nineteenth LAMPF Users Group meeting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bradbury, J.N.

    1986-02-01

    Separate abstracts were prepared for eight invited talks on various aspects of nuclear and particle physics as well as status reports on LAMPF and discussions of upgrade options. Also included in these proceedings are the minutes of the working groups for: energetic pion channel and spectrometer; high resolution spectrometer; high energy pion channel; neutron facilities; low-energy pion work; nucleon physics laboratory; stopped muon physics; solid state physics and material science; nuclear chemistry; and computing facilities. Recent LAMPF proposals are also briefly summarized. (LEW)

  15. Instrumentation and control upgrade plan for Browns Ferry nuclear plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belew, M.R.; Langley, D.T.; Torok, R.C.

    1992-01-01

    A comprehensive upgrade of the instrumentation and control (I C) systems at a power plant represents a formidable project for any utility. For a nuclear plant, the extra safety and reliability requirements along with regulatory constraints add further complications and cost. The need for the upgrade must, therefore, be very compelling, and the process must be well planned from the start. This paper describes the steps taken to initiate the I C upgrade process for Tennessee Valley Authority's (TVA's) Browns Ferry 2 nuclear plant. It explains the impetus for the upgrade, the expected benefits, and the process by which systemmore » upgrades will be selected and implemented.« less

  16. Radiological progression and its predictive risk factors in silicosis

    PubMed Central

    Lee, H; Phoon, W; Ng, T

    2001-01-01

    OBJECTIVES—To investigate the risk factors predicting radiological progression in silicosis in a prospective cohort study of patients with silicosis who were previously exposed to silica from granite dust.
METHODS—From among a total of 260 patients with silicosis contracted from granite work, 141 with available serial chest x ray films of acceptable quality taken over a period of 2 to 17 (mean 7.5) years, were selected for study. Ninety four (66.7%) had ended exposure 5 or more years perviously (mean 10.1 years, maximum 28 years). Radiological progression was assessed by paired comparison of the initial and most recent radiographs, with two or more steps of increase in profusion of small opacities according to the 12 point scale of the International Labour Organisation (ILO) classification of radiographs of pneumoconiosis, taken from the majority reading by a panel of three independent readers.
RESULTS—Overall, 37% of patients with silicosis had radiological evidence of progression. From the initial radiographs, 24 (31.6%) of those with radiological profusion category 1, 15 (37.5%) of those with radiological profusion category 2, and 13 (52%) of those with complicated silicosis (including all seven with category 3 profusion of small opacities) showed radiological progression. As expected, progression was more likely to be found after longer periods of follow up (the interval between the two chest x ray films) with a 20% increased odds of progression for every additional year of follow up. After adjustment for varying intervals of follow up, the probability of radiological progression was found to be significant if large opacities were present in the initial chest x ray film. Progression was also less likely to be found among those who had ended exposure to silica longer ago, although the result was of borderline significance (p=0.07). Tuberculosis was also associated with increased likelihood of progression (borderline significance).
CONCLUSIONS—There is a high probability of radiological progression in silicosis after high levels of exposure to granite dust among workers who were followed up for up to 17 years. A significant risk factor is the extent of radiological opacities in the initial chest x ray film. The probability of progression is also likely to be reduced with longer periods after the end of exposure.


Keywords: silicosis; radiological progression; granite quarry PMID:11404452

  17. Results of the radiological survey at the former ALCOA New Kensington Works, Pine and Ninth Streets, New Kensington, Pennsylvania (ANK002)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foley, R.D.; Brown, K.S.

    1992-10-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at the former ALCOA New Kensington Works, Pine and Ninth Streets, New Kensington, Pennsylvania. The survey was performed on November 12, 1991. The purpose of the survey was to determine whether the property was contaminated with radioactive residues, principally, as a result of work done for the Manhattan Engineer District in 1944. The survey included a gamma scan of three bays inside Building 18; measurement of direct alpha and beta-gamma levels in the same area; and collection of amore » dust sample for radionuclide analysis from the center of each bay. Results of the survey demonstrated no radionuclide concentrations or radiation measurements in excess of the DOE Formerly Utilized Sites Remedial Action Program guidelines for uranium. The radionuclide distributions were not significantly different from typical background levels in the Pittsburgh, Pennsylvania area.« less

  18. Analysis of fission and activation radionuclides produced by a uranium-fueled nuclear detonation and identification of the top dose-producing radionuclides.

    PubMed

    Kraus, Terry; Foster, Kevin

    2014-08-01

    The radiological assessment of the nuclear fallout (i.e., fission and neutron-activation radionuclides) from a nuclear detonation is complicated by the large number of fallout radionuclides. This paper provides the initial isotopic source term inventory of the fallout from a uranium-fueled nuclear detonation and identifies the significant and insignificant radiological dose producing radionuclides over 11 dose integration time periods (time phases) of interest. A primary goal of this work is to produce a set of consistent, time phase-dependent lists of the top dose-producing radionuclides that can be used to prepare radiological assessment calculations and data products (e.g., maps of areas that exceed protective action guidelines) in support of public and worker protection decisions. The ranked lists of top dose-producing radionuclides enable assessors to perform atmospheric dispersion modeling and radiological dose assessment modeling more quickly by using relatively short lists of radionuclides without significantly compromising the accuracy of the modeling and the dose projections. This paper also provides a superset-list of the top dose-producing fallout radionuclides from a uranium-fueled nuclear detonation that can be used to perform radiological assessments over any desired time phase. Furthermore, this paper provides information that may be useful to monitoring and sampling and laboratory analysis personnel to help understand which radionuclides are of primary concern. Finally, this paper may be useful to public protection decision makers because it shows the importance of quickly initiating public protection actions to minimize the radiological dose from fallout.

  19. Uncited Research Articles in Popular United States General Radiology Journals.

    PubMed

    Rosenkrantz, Andrew B; Chung, Ryan; Duszak, Richard

    2018-05-03

    This study aimed to characterize articles in popular general radiology journals that go uncited for a decade after publication. Using the Web of Science database, we identified annual citation counts for 13,459 articles published in Radiology, American Journal of Roentgenology, and Academic Radiology between 1997 and 2006. From this article cohort, we then identified all original research articles that accrued zero citations within a decade of publication. A concurrent equal-sized cohort of most cited articles was created. Numerous characteristics of the uncited and most cited articles were identified and compared. Only 47 uncited articles went uncited for a decade after publication. When compared to the 47 most cited articles over that same window, the uncited articles were significantly (P < .05) less likely to have a clinical focus, include a nonradiologist author and authors from multiple institutions and multiple nations, report research funding support and statistically significant findings, and include punctuation marks in their titles. Compared to the most cited articles, uncited articles also had significantly (P < .05) fewer authors, abstract words, manuscript words, references, tables, figure parts, and pages, as well as smaller subject sample sizes. Of articles published in popular general radiology journals, only a very small number of original research investigations remained uncited a decade after publication. Given that citations reflect the impact of radiology research, this observation suggests that journals are appropriately selecting meaningful work. Investigators seeking to avoid futile publication might consider their research initiatives in light of these characteristics. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  20. Post-deployment usability evaluation of a radiology workstation.

    PubMed

    Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi A; Oudkerk, Matthijs; Van Ooijen, Peter M A

    2016-01-01

    To determine the number, nature and severity of usability issues radiologists encounter while using a commercially available radiology workstation in clinical practice, and to assess how well the results of a pre-deployment usability evaluation of this workstation generalize to clinical practice. The usability evaluation consisted of semi-structured interviews and observations of twelve users using the workstation during their daily work. Usability issues and positive usability findings were documented. Each issue was given a severity rating and its root cause was determined. Results were compared to the results of a pre-deployment usability evaluation of the same workstation. Ninety-two usability issues were identified, ranging from issues that cause minor frustration or delay, to issues that cause significant delays, prevent users from completing tasks, or even pose a potential threat to patient safety. The results of the pre-deployment usability evaluation had limited generalizability to clinical practice. This study showed that radiologists encountered a large number and a wide variety of usability issues when using a commercially available radiology workstation in clinical practice. This underlines the need for effective usability engineering in radiology. Given the limitations of pre-deployment usability evaluation in radiology, which were confirmed by our finding that the results of a pre-deployment usability evaluation of this workstation had limited generalizability to clinical practice, it is vital that radiology workstation vendors devote significant resources to usability engineering efforts before deployment of their workstation, and to continue these efforts after the workstation is deployed in a hospital. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

Top