Qian, Feizhong; Zhu, Libo; Xu, Nengbin; Feng, Jiayong; Hong, Zhengfang; Xu, Lihong; Chen, Zhongquan; Wang, Shengle
2014-05-01
An ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/ MS) method was developed for the determination of picric acid and its reductive transformation product picramic acid in aqueous samples. A hydrophilic interaction liquid chromatography (HILIC) column (Acquity UPLC BEH HILIC; 100 mm x 2.1 mm, 1.7 microm) was used for the separation. Surface water samples could be injected into the UPLC system just after being filtered through a 0.2 microm membrane. The satisfactory recoveries of picric acid and picramic acid were in the range of 89% - 107%. Waste water samples were purified by solid phase extraction (SPE), and then were analyzed. The recoveries of picric acid and picramic acid in waste water were 72%-101%. The reproducibility of the method was good with the RSDs of 4.9% - 14.7%. The limits of detection (LODs) of picric acid and picramic acid were 0.1 microg/L and 0.3 microg/L, respectively. This proposed method is rapid, highly specific and suitable for the confirmation and quantitative determination of picric acid and picramic acid in surface water and waste water.
Lang, Lang; Meng, Zhaorui; Sun, Lan; Xiao, Wei; Zhao, Longshan; Xiong, Zhili
2018-02-01
Guizhi Fuling capsule (GFC), developed from the traditional Chinese prescription of Guizhi Fuling Wan, has been commonly used for the treatment of primary dysmenorrhea (PD). However, the intervention effective mechanism in vivo has not been well elucidated. In this study, an integrated plasma metabonomic strategy based on RP-UPLC-MS coupled with HILIC-UPLC-MS technique has been developed to investigate the global therapeutic effects and intervention mechanisms of GFC on dysmenorrhea rats induced by oxytocin. The 20 potential biomarkers were identified and primarily related to sphingolipid metabolism, steroid hormone biosynthesis, glycerophospholipid metabolism, amino acid metabolism, lipid metabolism and energy metabolism. The results showed that the GFC has therapeutic effects on rats with dysmenorrhea via the regulation of multiple metabolic pathways. Some new potential biomarkers associated with primary dysmenorrhea such as phenylalanine, tryptophan, taurine, carnitine, betaine, creatine and creatinine have been discovered in this study for the first time. This study provides a metabonomic platform based on RP-UPLC-MS complementary to HILIC-UPLC-MS technique to investigate both nonpolar and polar compounds, so as to get a more comprehensive metabolite information to yield insight into the pathophysiology of PD and assessing the efficacy of GFC on PD rats. Copyright © 2017 John Wiley & Sons, Ltd.
Xie, Honglei; Li, Chun; Liu, Ning
2013-08-01
The method for analysing sialic acid in infant formulas by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been established. Sialic acid in milk was released via acid hydrolysis, and purified by an HLB solid phase extraction cartridge. The UPLC separation was performed on an ACQUITY UPLC BEH HILIC column (50 mm x 2.1 mm, 1.7 microm) utilizing a gradient elution program of acetonitrile and water (containing 0.1% formic acid) as the mobile phases at a flow rate of 0.25 mL/min. Injection volume and column temperature were set at 5 microL and 30 degrees C, respectively. The identification and quantification were achieved by using electrospray ionisation (ESI)-MS/MS in positive ion mode and multiple reaction monitoring (MRM) mode. The linear range was from 0.05 to 5.0 mg/L for sialic acid and the correlation coefficient (R(2)) was greater than 0.99. The average recoveries spiked at the four concentration levels of 0.1, 0.5, 2.5 and 5.0 mg/L ranged between 84.3% and 98.9% with the relative standard deviations from 4.9% to 8.2%. The limit of detection was 0.01 mg/L. Therefore, this method has the characteristics of simple operation, high reproducibility and sensitivity. It can be widely applied to determine the total contents of sialic acid in infant formula, cow milk and human milk.
Cheng, Zai-Xing; Wu, Jin-Jun; Liu, Zhong-Qiu; Lin, Na
2013-03-01
Trigonelline (Tr) is the second most abundant alkaloid in coffee beans. This study developed an assay combining hydrophilic interaction chromatography with ultra performance liquid chromatography (HILIC-UPLC) for the quantification of Tr in rat plasma to determine its pharmacokinetic behavior. After the administration of Tr by gavage as well as intravenous injection and that of methanol extract of coffee beans (MECB) orally, blood samples from the experimental rats were analyzed using the HILIC-UPLC assay. Pharmacokinetic parameters were determined using the standard non-compartmental method and calculated using Practical Pharmacokinetic Program Version 87/97. The HILIC-UPLC assay was validated with the linear range of 0.12-100 μg·mL(-1) and a lower limit of quantitation of 0.12 μg·mL(-1). Its accuracy, precision, recovery, and stability were within acceptable limits. The AUC(0-∞) (where AUC is the area under the plasma concentration-time curve) values were determined to be (4 066.83 ± 1 244.41) and (3 544.29 ± 908.80) min·μg·mL(-1) after Tr was orally and intravenously administered, respectively. It was (4 566.75 ± 1 435.64) min·μg·mL(-1) after MECB was orally administered. The absolute bioavailability of Tr alone reached 57.37%, whereas that of Tr in MECB was 64.42%. The relative bioavailability of the alkaloid was 112.29%. The HILIC-UPLC assay for Tr determination is simple and accurate, and also exhibits good reproducibility. The bioavailability of stand-alone Tr and that of Tr in MECB were both good. Tr alone and that in MECB orally administered did not exhibit any significant difference. Copyright © 2013 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
Advances in analytical methodologies to guide bioprocess engineering for bio-therapeutics.
Saldova, Radka; Kilcoyne, Michelle; Stöckmann, Henning; Millán Martín, Silvia; Lewis, Amanda M; Tuite, Catherine M E; Gerlach, Jared Q; Le Berre, Marie; Borys, Michael C; Li, Zheng Jian; Abu-Absi, Nicholas R; Leister, Kirk; Joshi, Lokesh; Rudd, Pauline M
2017-03-01
This study was performed to monitor the glycoform distribution of a recombinant antibody fusion protein expressed in CHO cells over the course of fed-batch bioreactor runs using high-throughput methods to accurately determine the glycosylation status of the cell culture and its product. Three different bioreactors running similar conditions were analysed at the same five time-points using the advanced methods described here. N-glycans from cell and secreted glycoproteins from CHO cells were analysed by HILIC-UPLC and MS, and the total glycosylation (both N- and O-linked glycans) secreted from the CHO cells were analysed by lectin microarrays. Cell glycoproteins contained mostly high mannose type N-linked glycans with some complex glycans; sialic acid was α-(2,3)-linked, galactose β-(1,4)-linked, with core fucose. Glycans attached to secreted glycoproteins were mostly complex with sialic acid α-(2,3)-linked, galactose β-(1,4)-linked, with mostly core fucose. There were no significant differences noted among the bioreactors in either the cell pellets or supernatants using the HILIC-UPLC method and only minor differences at the early time-points of days 1 and 3 by the lectin microarray method. In comparing different time-points, significant decreases in sialylation and branching with time were observed for glycans attached to both cell and secreted glycoproteins. Additionally, there was a significant decrease over time in high mannose type N-glycans from the cell glycoproteins. A combination of the complementary methods HILIC-UPLC and lectin microarrays could provide a powerful and rapid HTP profiling tool capable of yielding qualitative and quantitative data for a defined biopharmaceutical process, which would allow valuable near 'real-time' monitoring of the biopharmaceutical product. Copyright © 2016 Elsevier Inc. All rights reserved.
Prokopenko, Yuliya; Jakštas, Valdas; Žvikas, Vaidotas; Georgiyants, Victoriya; Ivanauskas, Liudas
2018-05-18
The aim of research was to study the content of amino acids using in extracts of Fumaria schleicheri L., Ocimum basilicum L., and Corylus avellana L. by HILIC MS/MS method. Separation of amino acids in the samples was carried out with Acquity H-class UPLC system (Waters, Milford, USA) equipped with SeQuant ZIC-Hilic collumn (2.1 × 150 mm, 3.5 μm) (Merck Millipore, Darmstadt, Germany). The MS/MS fragment ion chromatograms of the test solutions established the presence of 19 amino acids. The obtained results have shown that O. basilicum L. characterized the highest concentrations of different neurogenic amino acids (128.1 mg/kg), comparing with F. schleicheri L. and C. avellana L. (57.72 and 52.91 mg/kg, respectively).
Gritti, Fabrice; Sehajpal, Jyotsna; Fairchild, Jacob
2017-03-17
The peak distortion observed in hydrophilic interaction chromatography (HILIC) may be caused by the sample diluent to mobile phase mismatch. The United States Pharmacopeia (USP) method for organic impurities in cetirizine HCl tablets calls for such a mismatch, having a higher concentration of strong solvent in the sample diluent than in the mobile phase. A significant peak deformation is reported for cetirizine (a second-generation antihistamine) when it is purified on a Ethylene Bridged Hybrid (BEH) HILIC column (4.6mm×100mm, 2.5μm particles) using an acetonitrile-water eluent mixture and a sample diluent containing 7% and 9% water (in volume), respectively. The mechanism and physical origin of such peak distortion are related to (1) the diluent-to-eluent excess of water that propagates along the column at a velocity similar to that of the analyte, (2) the significant drop of the Henry's constant of the analyte upon increasing water concentration in the eluent, (3) the sample volume injected, and (4) to the pre-column sample dilution factor that depends on the characteristics of the LC instrument used. This proposed mechanism is validated from the calculation of the concentration profiles of cetirizine and water by using the equilibrium-dispersive (ED) model of chromatography. The observed distortion of cetirizine peaks is successfully predicted from the measurement of (1) the excess adsorption isotherm of water from acetonitrile onto the BEH HILIC adsorbent, (2) the retention factor of cetirizine as a function of the volume fraction (7, 8, and 9%) of water in the mobile phase, and (3) of the pre-column sample dispersion related to the instrument used (HPLC or UHPLC). The results of the calculations enables the user to anticipate the impacts of the diluent-to-eluent mismatch in water content, the injection volume, the analyte retention under infinite dilution, and of the pre-column sample dispersion on the amplitude of peak distortion in HILIC. Appropriate and permitted alterations of the USP method are then suggested based on a sound physico-chemical approach. Copyright © 2017 Elsevier B.V. All rights reserved.
Prinsen, Hubertus C M T; Schiebergen-Bronkhorst, B G M; Roeleveld, M W; Jans, J J M; de Sain-van der Velden, M G M; Visser, G; van Hasselt, P M; Verhoeven-Duif, N M
2016-09-01
Amino acidopathies are a class of inborn errors of metabolism (IEM) that can be diagnosed by analysis of amino acids (AA) in plasma. Current strategies for AA analysis include cation exchange HPLC with post-column ninhydrin derivatization, GC-MS, and LC-MS/MS-related methods. Major drawbacks of the current methods are time-consuming procedures, derivative problems, problems with retention, and MS-sensitivity. The use of hydrophilic interaction liquid chromatography (HILIC) columns is an ideal separation mode for hydrophilic compounds like AA. Here we report a HILIC-method for analysis of 36 underivatized AA in plasma to detect defects in AA metabolism that overcomes the major drawbacks of other methods. A rapid, sensitive, and specific method was developed for the analysis of AA in plasma without derivatization using HILIC coupled with tandem mass-spectrometry (Xevo TQ, Waters). Excellent separation of 36 AA (24 quantitative/12 qualitative) in plasma was achieved on an Acquity BEH Amide column (2.1×100 mm, 1.7 μm) in a single MS run of 18 min. Plasma of patients with a known IEM in AA metabolism was analyzed and all patients were correctly identified. The reported method analyzes 36 AA in plasma within 18 min and provides baseline separation of isomeric AA such as leucine and isoleucine. No separation was obtained for isoleucine and allo-isoleucine. The method is applicable to study defects in AA metabolism in plasma.
Sotgia, Salvatore; Pisanu, Elisabetta; Cambedda, Debora; Pintus, Gianfranco; Carru, Ciriaco; Zinellu, Angelo
2014-09-01
A new efficient and sensitive precolumn hydrophilic interaction ultra-performance liquid chromatography (HILIC-UPLC) method was established for the quantitative determination of L-ergothioneine (ERT) in milk. After derivatization of ERT with 7-diethylamino-3-[4-(iodoacetamido)phenyl]-4-methylcoumarin, chromatographic separation was achieved in a fairly short time, less than 5 min, on a 100 × 2.1 mm Waters Cortecs UPLC HILIC 1.6-μm column, by using a mixture of 30 mmol/L ammonium acetate/acetonitrile (10:90, v/v) as a mobile phase flowing isocratically at 0.9 mL/min. Limit of detection and the limit of quantification were 0.03 and 0.10 μmol/L, respectively. The method exhibited linearity in a concentration range of 0.16 and 5.08 μmol/L. Mean recovery was 106.66%, whereas intra- and interassay precisions were determined to be within 6 RSD%. On average, ERT concentration in different commercially available classes of cow milk was found to be 0.442 ± 0.191 μmol/L, with the highest levels in the ultra-high temperature milks and low values in the unprocessed and HTST whole milks. In this light, our experiments suggest that ERT could be used as a marker for the heat treatment of milk. © 2014 Institute of Food Technologists®
Li, Kun-Yan; Zhou, Yan-Gang; Ren, Hua-Yi; Wang, Feng; Zhang, Bi-Kui; Li, Huan-De
2007-05-01
The ultra-performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-ESI-MS/MS) method has been developed to perform the determination of quetiapine, perospirone, aripiprazole and quetiapine sulfoxide in in vitro samples in less than 3 min. The UPLC separation was carried out using an Acquity UPLC BEH C18 column (100 mm x 2.1mm i.d., 1.7 microm particle size) that provided high efficiency and resolution in combination with high linear velocities. The UPLC system was coupled to a Waters Micromass Quattro Premier XE tandem quadrupole mass spectrometer. This system permits high-speed data acquisition without peak intensity degradation, and produces sharp and narrow chromatographic peaks (w(h) about 2.5s) of compounds. The determination was performed in multiple reaction monitoring (MRM) mode. The quantification parameters of the developed method were established, obtaining instrumental LODs lower than 0.005 microg/l and a repeatability at a low concentration level lower than 10% CV (n=10). Finally, the method was successfully applied to the analysis of atypical antipsychotics and some metabolites in in vitro samples.
Nie, Hui; Yan, Hui; Qian, Da-Wei; Duan, Jin-Ao; Ou, Yang-Zhen; Qian, Ye-Fei; Guan, Han-Liang
2013-07-01
To establish the UPLC specific chromatogram of Lily and analyze the specific peaks compositions by ESI-QTOF-MS. The samples were conducted by ACQUITY UPLC BEH C18 Column (2.1 mm x 100 mm, 1.7 microm) and eluted with acetonitrile and 0.1% formic acid at the flow rate of 0.4 mL/min. The detection wavelength was set at 320 nm and column temperature was 35 degrees C. Negative ion mode was chosen for qualitative analysis. The capillary voltage was set at 3.0 kV. The nebulization gas was set to 600 L/h at 350 degrees C, and the source temperature was 120 degrees C. The specific chromatogram of Lily was obtained. There were 19 common peaks. Twelve phenylpropenoid glycerides compositions were identified. Among them, 6 compositions were identified by comparison with the reference substances and others were identified by MS and MS2 data. UPLC specific chromatogram can be used for the quality evaluation of Lily, giving support to quality control comprehensively.
Tang, Ce; Wen, Jian; Wang, Jing; Zhao, Ke-Hui; Fan, Gang; Meng, Xian-Li; Zou, Zhong-Mei; Zhang, Yi
2017-04-01
This study is to develop an UPLC-PDA method for determination of 10 major components in Pterocephalus. The UPLC-PDA assay was performed on a Waters Acquity UPLCR BEH C₁₈(2.1 mm ×100 mm,1.7 μm), and the column temperature was at 30 ℃. The mobile phase consists of water containing 0.2% phosphoric acid (A) and acetonitrile (B) in gradient elution at a flow rate of 0.4 mL•min⁻¹. The detection wave length was set at 237 and 325 nm, and the injection volume was 1 μL in the UPLC system. The linear range of 10 detected compounds were good (r≥0.999 7), and the overall recoveries ranged from 96.30% to 103.0%, with the RSD ranging from 0.72% to 2.9%. The method was simple, accurate and reproducible, which can be used for the simultaneous determination of the content of ten major components in P. hookeri. Copyright© by the Chinese Pharmaceutical Association.
[Serum pharmacochemistry of Qinbai Qingfei concentrated pellets based on UPLC-Q-TOF-MS].
Liu, Ye; Wei, Wen-Feng; Huo, Jin-Hai; Wang, Wei-Ming
2017-02-01
To analyze the main components of Qinbai Qingfei concentrated pellets in rat serum with UPLC-Q-TOF-MS technology and serum pharmacochemistry theory. After gavage administration with Qinbai Qingfei concentrated pellets, blood was collected from hepatic portal vein. ACQUITY UPLC BEH C₁₈(2.1 mm×100 mm, 1.7 μm) was used, with 0.1% formic acid agueous solution(A)-0.1%formic acid and acetonitrile(B) as the mobile phase for gradient elution. The flow rate was 0.3 mL•min⁻¹, the column temperature was maintained at 35 ℃. Through the comparative analysis fingerprints of Qinbai Qingfei concentrated pellets, drug containing-serum and blank serum, and with the help Peakview and Metabolitepilot software, components in serum were defined. A total of 28 compounds were identified, including 18 prototypes and 10 metabolites. As a result, UPLC-Q-TOF-MS technology and serum pharmacochemistry theory were applied to comprehensively expound Qinbai Qingfei concentrated pellets'constituents migrating to rat serum, and provide scientific basis for further studies for in vivo metabolic process and effective material base. Copyright© by the Chinese Pharmaceutical Association.
Dinç, Erdal; Büker, Eda
2012-01-01
A new application of continuous wavelet transform (CWT) to overlapping peaks in a chromatogram was developed for the quantitative analysis of amiloride hydrochloride (AML) and hydrochlorothiazide (HCT) in tablets. Chromatographic analysis was done by using an ACQUITY ultra-performance LC (UPLC) BEH C18 column (50 x 2.1 mm id, 1.7 pm particle size) and a mobile phase consisting of methanol-0.1 M acetic acid (21 + 79, v/v) at a constant flow rate of 0.3 mL/min with diode array detection at 274 nm. The overlapping chromatographic peaks of the calibration set consisting of AML and HCT mixtures were recorded rapidly by using an ACQUITY UPLC H-Class system. The overlapping UPLC data vectors of AML and HCT drugs and their samples were processed by CWT signal processing methods. The calibration graphs for AML and HCT were computed from the relationship between concentration and areas of chromatographic CWT peaks. The applicability and validity of the improved UPLC-CWT approaches were confirmed by recovery studies and the standard addition technique. The proposed UPLC-CWT methods were applied to the determination of AML and HCT in tablets. The experimental results indicated that the suggested UPLC-CWT signal processing provides accurate and precise results for industrial QC and quantitative evaluation of AML-HCT tablets.
Abdulla, Alan; Bahmany, Soma; Wijma, Rixt A; van der Nagel, Bart C H; Koch, Birgit C P
2017-08-15
Contemporary β-lactam antibiotic dosing is debatable in severely ill patients, since the occurrence of pathophysiological changes in critical illness can result in great inter-individual variability. Therapeutic drug monitoring (TDM) is a commonly used dosing strategy to optimize exposure and thereby minimize toxicity and maximize the efficacy. Currently, TDM of β-lactam antibiotics is rarely performed, due to poor availability in clinical practice. We describe an ultrafast Hydrophilic-Interaction Chromatography (HILIC) based UPLC-MS/MS method for the determination of amoxicillin, benzylpenicillin, cefotaxime, cefuroxime, ceftazidime, flucloxacillin, imipenem, meropenem and piperacillin in human plasma. This method involves simple sample preparation steps and was comprehensively validated according to standard FDA guidelines. For all analytes, mean accuracy and precision values were within the acceptance value. The lower and upper limits of quantification were found to be sufficient to cover the therapeutic range for all antibiotics. Finally, the method was successfully applied in a large pharmacokinetic study performed in the intensive care setting, and the feasibility of the analytical procedure was demonstrated in routine clinical practice. To the best of our knowledge, we report here the first HILIC-based UPLC-MS/MS assay for the determination of β-lactam antibiotics in human plasma. This simple, sensitive and ultrafast assay requires small-volume samples and can easily be implemented in clinical laboratories to promote the TDM of β-lactam antibiotics. Copyright © 2017 Elsevier B.V. All rights reserved.
Qiu, Xiangjun; Zhao, Jian-Long; Hao, Cong; Yuan, Canli; Tian, Nuan; Xu, Zhi-Sheng; Zou, Ruan-Min
2016-05-30
In this study, a sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed to determine mangiferin and neomangiferin in rat plasma simultaneously. Chromatographic separation was carried out on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a Xevo TQD triple quadruple mass spectrometer coupled with an electrospray ionization (ESI) source. The MRM transitions of m/z 423.2 → 303.1 and m/z 585.0 → 273.1 were used to quantify for mangiferin and neomangiferin, respectively. The linearity of this method was found to be within the concentration range of 5-2000 ng/mL for mangiferin, and 2-1000 ng/mL for neomangiferin in rat plasma, respectively. Only 3.0 min was needed for an analytical run. This assay was used to support a preclinical study to investigate the pharmacokinetics of mangiferin and neomangiferin in rats. Copyright © 2016 Elsevier B.V. All rights reserved.
Jamalapuram, Seshulatha; Vuppala, Pradeep K.; Mesangeau, Christophe; McCurdy, Christopher R.; Avery, Bonnie A.
2014-01-01
A selective, rapid and sensitive ultra performance liquid chromatography mass spectrometry (UPLC/MS) method was developed and validated to quantitate a highly selective mixed-affinity sigma receptor ligand, CM156 (3-(4-(4-cyclohexylpiperazin-1-yl)butyl)benzo[d] thiazole-2(3H)-thione), in rat plasma. CM156 and the internal standard (aripiprazole) were extracted from plasma samples by a single step liquid–liquid extraction using chloroform. The analysis was carried out on an ACQUITY UPLCTM BEH HILIC column (1.7 µm, 2.1 mm × 50 mm) with isocratic elution at flow rate of 0.2 mL/min using 10 mM ammonium formate in 0.1% formic acid and acetonitrile (10:90) as the mobile phase. The detection of the analyte was performed on a mass spectrometer operated in selected ion recording (SIR) mode with positive electrospray ionization (ESI). The validated analytical method resulted in a run time of 4 min and the retention times observed were 2.6 ± 0.1 and 2.1 ± 0.1 min for CM156 and the IS, respectively. The calibration curve exhibited excellent linearity over a concentration range of 5–4000 ng/mL with the lower limit of quantification of 5 ng/mL. The intra- and inter-day precision values were below 15% and accuracy ranged from −6.5% to 5.0%. The mean recovery of CM156 from plasma was 96.8%. The validated method was applied to a pilot intravenous pharmacokinetic study in rats. PMID:22406103
Zhao, Yu-Jiao; Xu, Wen-Hui; Shen, Xiao-Li; Tian, Jun-Sheng; Qin, Xue-Mei
2017-02-01
This research is to establish TLC and UPLC methods for simultaneous determination of 3 atractylenolides in Atractylodes macrocephala. Silica gel GF254 plate was used for identification of A. macrocephala, and UPLC-PDA gradient elution method was used to simultaneously determine atractylenolide Ⅰ, Ⅱ and Ⅲ. The Waters BEH C₁₈ column(2.1 mm×100 mm,1.7 μm)with acetonitrile-water as mobile phase and the wavelength of UV detector of 235 nm were performed. The quality control study showed that the characteristic for identification by TLC was distinct and highly specific. The method of content determination was in accordance with the regulations. The quantitative evaluation of atractylenolide Ⅰ,Ⅱ and Ⅲ was in good linear range(r>0.999 9), and the average recovery was 93.48%(RSD 1.4%),94.97%(RSD 1.6%),92.71%(RSD 1.2%),respectively. TLC identification was in good specificity and repeatability, and the UPLC-PDA method for the simultaneous determination of 3 atractylenolides was simple and reliable for the quality control of A.macrocephala. Copyright© by the Chinese Pharmaceutical Association.
Sharma, Upendra K; Sharma, Nandini; Sinha, Arun K; Kumar, Neeraj; Gupta, Ajai P
2009-10-01
In this study, two novel chromatographic methods based on monolithic column high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were developed for the ultrafast determination of principal flavor compounds namely vanillin, vanillic acid, p-hydroxybenzoic acid, and p-hydroxybenzaldehyde in ethanolic extracts of Vanilla planifolia pods. Good separation was achieved within 2.5 min using Chromolith RP18e column (100 mm x 4.6 mm) for HPLC and Acquity BEH C-18 (100 mm x 2.1 mm, 1.7 microm) column for UPLC. Both methods were compared in terms of total analysis time, mobile phase consumption, sensitivity, and validation parameters like precision, accuracy, LOD, and LOQ. Further, system suitability test data including resolution, capacity factor, theoretical plates, and tailing factor was determined for both the methods by ten replicate injections. Monolithic column based HPLC gave better results for most of the selected parameters while UPLC was found to be more eco-friendly with low mobile phase consumption and better sensitivity. Both methods may be used conveniently for the high throughput analysis of large number of samples in comparison to traditional particulate column.
Qin, Feng; Huang, Jun; Qiu, Xinjian; Hu, Sihang; Huang, Xi
2011-01-01
A simple, sensitive, and reliable ultra-performance liquid chromatography (UPLC) method has been developed for simultaneous determination of 22 major constituents in modified xiaoyao san (MXS), a multiherbal formula. The chromatographic separation was performed on an ACQUITY UPLC BEH C18 column (150 x 2.1 mm, 1.7 microm, particle size), with an aqueous 0.5% acetic acid and acetonitrile mobile phase gradient. The method was validated for linearity (r2 >0.9937), intraday and interday precision (RSD <8.51%), recovery (91.18-107.73%), LOD (0.02-4.17 ng/mL), and LOQ (0.05-12.50 ng/mL). The established method was successfully applied to quantify the 22 marker compounds in MXS, which provided a useful basis of overall evaluation of the quality of MXS.
Zhang, Hui-ye; Xu, Xiao-fei; Huang, Yong; Wamg, De-qin; Deng, Qiao-hua
2014-06-01
To establish an analytical method for characteristic fingerprint and determination of main components of Andrographis paniculata Extract by UPLC. The chromatographic conditions were Waters ACQUITY UPLC BEH-C18 (2. 1 mm x 0 mm,1.7 μm)by gradient elute using acetonitrile-water as mobile phase(0 -2 min,20% ~ 25% A;2 ~ 5 min,25% ~ 35% A;5 ~ 7 min,35% A;7 ~10 min,35%~ 55% A) at a flow rate of 0. 5 min/mL,detecting wavelength at 220 nm. Results:Contents of the andrographolide, neoandrographolide, 14-deoxyandrographolide and 14-deoxy-l11,12-didehydroandrographolide had good resolution with the correlation coefficients exceed 0. 9999 and the average percent recovery lied in 97. 2% to 103.9%, RSD was less than 3.0% (n = 6). The chromatograms of Andrographis paniculata Extract shared seven common peaks in which four of them were recognized by reference standard with the similarities over 0. 9. It is a fast,accurate and validated method,and can be useful in quality evaluations of Andrographis paniculata Extract.
[Determination of terpene lactones in Ginkgo biloba leaves in different ages by UPLC-TQ-MS].
Yao, Xin; Zhou, Gui-Sheng; Tang, Yu-Ping; Qian, Ye-Fei; Shang, Er-Xin; Su, Shu-Lan; Qian, Da-Wei; Duan, Jin-Ao
2013-02-01
To establish an ultra-high performance liquid chromatography coupled with triple quadrupole mass (UPLC-TQ-MS) for determination of four terpene lactones. Chromatographic separation was carried out on a ACQUITY UPLC BEH C18 column (2.1 mm x 100 mm, 1.7 microm) with isocratic elution of 70% methanol at a flow rate of 0.4 mL x min(-1), the column temperature was set at 30 degrees C; Waters Xevo TQ worked in multiple reaction monitoring mode. All calibration curves were linear (r > 0.990 3) over the tested ranges. The average recoveries ranged from 98.83% to 103.9% with RSD value below 3.0%. The contents of total terpene lactones in Ginkgo biloba leaves were significantly different in different ages. The contents in the leaves of young ginkgo tree were higher than that in old tree. The method was simple and fast with high precision, sensitivity and repeatability, which can be used for qualitative and quantitative analysis of terpene lactones in G. biloba leaves.
Quantitative analysis of boeravinones in the roots of Boerhaavia Diffusa by UPLC/PDA.
Bairwa, Khemraj; Srivastava, Amit; Jachak, Sanjay Madhukar
2014-01-01
Boerhaavia diffusa is a perennial herb belonging to Nyctaginaceae. Various classes of chemical constituents such as phenolics (boeravinones), terpenoids and organic acids have been reported in B. diffusa roots. As boeravinones have been proposed as putative active constituents for the anti-cancer, spasmolytic and anti-inflammatory activities exhibited by B. diffusa extracts, it is worthwhile developing and validating an ultra-performance liquid chromatography (UPLC) method for analysis of boeravinones in B. diffusa roots. To develop and validate a simple, accurate, robust and rapid UPLC analytical method for quality control of B. diffusa roots. Samples for analysis were prepared by refluxing powdered root material with methanol for 2 h. The extracts were concentrated, dried and stored at -20°C until their use. A UPLC with photodiode array (PDA) method was developed and validated for the quantification of boeravinones in the roots of B. diffusa. The separation of boeravinones was achieved using a BEH Shield C18 -column (2.1 × 100 mm, 1.7 µm) with gradient elution of methanol and water (0.1% acetic acid), at a flow rate of 0.4 mL/min and detection was carried out at λmax 273 nm. The UPLC method developed showed good linearity (r(2) ≥ 0.9999), accuracy and precision. The UPLC method developed provided a selective, sensitive and rapid analytical method for the quantification of boeravinones in B. diffusa roots. All the validation parameters were found to be within the permissible limits as per International Conference on Harmonisation guidelines. Copyright © 2014 John Wiley & Sons, Ltd.
Determination and pharmacokinetic study of Enasidenib in rat plasma by UPLC-MS/MS.
Pang, Ni-Hong; Liu, Qian; Lu, Xiang-Ran; Yang, Su-Fen; Lin, Dong-Dong; Hu, Guo-Xin
2018-04-27
Enasidenib, an oral product for treating Acute Myeloid Leukemia, has been approved by FDA in Aug, 2017. In this study, we set up an ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS) method for measuring Enasidenib and imatinib (internal standard, IS), simultaneously. Enasidenib and imatinib were separated on an ACQUITY UPLC BEH C 18 Column (2.1 mm × 50 mm, 1.7 μm, 132 Å). Mass detection was carried out by electrospray ionization in the position mode, and the multiple reaction monitoring transitions were m/z 474.23 → 456.17 and m/z 494.30 → 394.20 for Enasidenib and imatinib, respectively. Linearity (2 - 500 ng·mL -1 , R 2 > 0.999), precision and accuracy (RE < ± 15%), extraction recovery (≥ 96.69%), matrix effect (≥ 96.47%) and stability (RE < ± 10%) were validated which demonstrated the robustness of our method. This rapid, efficient and reliable UPLC-MS/MS method shows specificity and repeatability of Enasidenib in rat plasma and can be used in further pharmacokinetic studies. Copyright © 2018 Elsevier B.V. All rights reserved.
Tao, Huang; Yun-Hai, Guo; He-Xiang, Liu; Yi, Zhang
2018-04-19
To establish a method for the quantitative determination of serotonin and dopamine in the nervous system of Biomphalaria glabrata by using ultra high performance liquid chromatography-tandem quadrupole mass spectrometry (UPLC MS/MS) . The B. glabrata nervous system was broken in the pure methanol solution after obtaining it by dissecting with microscope. Then, the supernatant containing the target substance after twice high speed centrifugation was got. The extraction was separated on an ACQUITY UPLC BEH Amide column with Waters TQ-XS series mass spectrometry detector, with ESI source and positive electrospray ionization mode when the machine testing. The detection limit of serotonin was 0.03 ng/ml and the limit of quantification was 0.1 ng/ml. The detection limit of dopamine was 0.05 ng/ml and the limit of quantification was 0.15 ng/ml. The recoveries of serotonin ranged from 90.68% to 94.72% over the range of 1 to 40 ng/ml. The recoveries of dopamine ranged from 91.68% to 96.12% over the range of 1.0 ng/ml to 40 ng/ml. The established UPLC MS/MS method is simple, stable and reproducible. It can be used for the quantitative analysis of serotonin and dopamine in the nervous system of B. glabrata snails.
Ultrafast quantification of β-lactam antibiotics in human plasma using UPLC-MS/MS.
Carlier, Mieke; Stove, Veronique; De Waele, Jan J; Verstraete, Alain G
2015-01-26
There is an increasing interest in monitoring plasma concentrations of β-lactam antibiotics. The objective of this work was to develop and validate a fast ultra-performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS) for simultaneous quantification of amoxicillin, cefuroxime, ceftazidime, meropenem and piperacillin with minimal turn around time. Sample clean-up included protein precipitation with acetonitrile containing 5 deuterated internal standards, and subsequent dilution of the supernatant with water after centrifugation. Runtime was only 2.5 min. Chromatographic separation was performed on a Waters Acquity UPLC system using a BEH C18 column (1.7 μm, 100 mm × 2.1 mm) applying a binary gradient elution of water and methanol both containing 0.1% formic acid and 2 mmol/L ammonium acetate on a Water TQD instrument in MRM mode. All compounds were detected in electrospray positive ion mode and could be quantified between 1 and 100 mg/L for amoxicillin and cefuroxime, between 0.5 and 80 mg/L for meropenem and ceftazidime, and between 1 and 150 mg/L for piperacillin. The method was validated in terms of precision, accuracy, linearity, matrix effect and recovery and has been compared to a previously published UPLC-MS/MS method. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, Hong; Gao, Yu-Mei; Zhang, Jing; Wang, Lin; Wang, Xiao-Xin
2013-01-01
Objective: To establish an ultra-performance liquid chromatography (UPLC) fingerprinting method for quality control of Phragmitis rhizoma from Baiyangdian. Materials and Methods: Ultrasonic extraction with 70% methanol was performed on 10 samples of P. rhizoma collected from 10 different villages in Baiyangdian. The sample solutions were analyzed by Waters UPLC equipped with the ACQUITY UPLC BEH C18 column and photodiode array (PDA) detector, and gradient eluted with acetonitrile/water as the mobile phase. The flow rate was set to 0.1 mL/min; the column temperature was set to 25°C; and the detection wavelength was set to 285 nm. Results: The chromatograms of the 10 samples showed 27 common peaks, of which one was identified as the ferulic acid standard. The similarity indexes were all above 0.82. Hierarchical cluster analysis showed that the constituents and their quantities differed according to the diameter of the original plant, which is related to its age. Conclusion: The UPLC fingerprinting method had the advantages of being fast, accurate, and highly efficient; this indicated that it can be used for quality control of P. rhizoma produced in Baiyangdian. Also, the relation between the quality and diameter/age of the plant needs to be further investigated. PMID:24124278
Dubey, Sunil Kumar; Saha, R N; Jangala, Hemanth; Pasha, S
2013-12-01
A new ultra-performance liquid chromatography-electrospray ionization mass spectrometry (UPLC-MS/ESI) method for simultaneous determination of venlafaxine (VEN) and its metabolite O-desmethylvenlafaxine (ODV) in rat plasma has been developed and validated using Venlafaxine d6 as the internal standard. The compounds and internal standard were extracted from plasma by solid phase extraction. The UPLC separation of the analytes was performed on ACQUITY UPLC ® BEH Shield RP18 (1.7 µm, 100 mm×2.1 mm) column, using isocratic elution with mobile phase constituted of water (containing 2 mM ammonium acetate): acetonitrile (20:80, v/v) at a flow rate of 0.3 mL/min. All of the analytes were eluted within 1.5 min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer, operating in multiple reaction monitoring (MRM) and positive ion mode. The precursor to product ion transitions monitored for VEN, ODV and Venlafaxine d6 were m / z 278.3→121.08, 264.2→107.1 and 284.4→121.0, respectively. The developed and validated method was used for the pharmacokinetic study of VEN in rats.
[Comparison of chemical composition between fresh and processed Bufonis Venenum by UPLC-TQ-MS].
Wang, Zi-yue; Wang, Hong-lan; Zhou, Jing; Ma, Hong-yue; Gong, Yan; Yan, Wen-li; Qian, Da-wei
2015-10-01
Toad venom is the Bufo bufo gargarizans or B. melanostictus after the ears of the gland secretion, used in the treatment of various cancers in recent years. Research shows that the main anti-tumor components in bufadienolide. Bufadienolide have free type structure and conjunct type structure. To identify and clarify the difference between bufogenin and bufotoxin contained in Bufonis Venenum, which was from B. bufo gargarizans, an UPLC-TQ-MS method has been established. UPLC-TQ-MS method was used to identify and quantify the major bufadienolides in Bufonis Venenum. UPLC-TQ-MS assay with positive ion mode was performed on a Waters ACQUITY UPLC BEH C, (2.1 mm x 100 mm, 1.7 µm) with the mobile phase consisting of 0. 1% aqueous formic and acidacetonitrile in gradient elution at a flow rate of 0.4 mL · min⁻¹ and the column temperature was set at 35 °C. By comparing their retention time and high resolution mass data of Bufonis Venenum extracts, 37 effective components were primarily identified by MS/MS analysis in positive ion mode. Twenty-six of them were free-type bufadienolides (bufogenin), 11 of them were conjugated bufadienolides. There were significant differences in the main composition between fresh and processed Bufonis Venenum. The study found that the chemical composition of toad venom through great changes after processing, conjunct type content is much less, free type content as well change.
Klevorn, Claire M; Dean, Lisa L
2018-02-01
Raw peanuts in the USA are subjected to thermal processing, such as dry-roasting, prior to consumption. A multi-instrument metabolomics-based platform along with targeted analyses was used to determine changes in the low-molecular-weight compound composition of peanuts due to dry-roasting. Runner and virginia-type peanut seeds were characterized using several analytical platforms including (RP)/UPLC-MS/MS (positive and negative ion mode ESI) and HILIC/UPLC-MS/MS with negative ion mode ESI. Of the 383 compounds identified, 16 compounds were unique to the roasted peanuts. Using pathway analysis, compounds associated with arginine and proline metabolism were found to be the most changed. Products of chemical degradation and compounds contained within the vesicular bodies of the peanut increased after roasting. Dry-roasting had a significant impact on the levels and types of low-molecular-weight compounds present. These findings provide useful information about composition changes due to roasting. Published by Elsevier Ltd.
Miller, Julie V; LeBouf, Ryan F; Kelly, Kimberly A; Michalovicz, Lindsay T; Ranpara, Anand; Locker, Alicia R; Miller, Diane B; O'Callaghan, James P
2018-05-28
Many veterans of the 1991 Persian Gulf War (GW) returned with a chronic multisymptom illness that has been termed Gulf War Illness (GWI). Previous GWI studies have suggested that exposure to acetylcholinesterase inhibitors (AChEIs) in theater, such as sarin and/or pesticides, may have contributed to the symptomatology of GWI. Additionally, concomitant high physiological stress experienced during the war may have contributed to the initiation of the GWI phenotype. While inhibition of AChE leading to accumulation of acetylcholine (ACh) will activate the cholinergic anti-inflammatory pathway, the signature symptomatology of GWI has been shown to be associated with neuroinflammation. To investigate the relationship between ACh and neuroinflammation in discrete brain regions, we used our previously established mouse model of GWI, which combines an exposure to a high physiological stress mimic, corticosterone (CORT), with GW-relevant AChEIs. The AChEIs used in this study were diisopropyl fluorophosphate (DFP), chlorpyrifos oxon (CPO), and physostigmine (PHY). After AChEI exposure, ACh concentrations for cortex (CTX), hippocampus (HIP), and striatum (STR) were determined using hydrophilic interaction liquid chromatography (HILIC) with ultra-performance liquid chromatography (UPLC)-tandem-mass spectrometry (MS/MS). CORT pretreatment ameliorated the DFP-induced ACh increase in HIP and STR, but not CTX. CORT pretreatment did not significantly alter ACh levels for CPO and PHY. Further analysis of STR neuroinflammatory biomarkers revealed an exacerbated CORT+AChEI response, which does not correspond to measured brain ACh. By utilizing this new analytical method for discrete brain region analysis of ACh, this work suggests the exacerbated neuroinflammatory effects in our mouse model of GWI are not driven by the accumulation of brain region-specific ACh.
Sun, Yanchun; Xu, Xianzhu; Mou, Zhenbo; Wang, Jing; Tan, Zhijun; Wu, Song
2012-12-01
A rapid, sensitive, and reliable ultra-performance liquid chromatography (UPLC) coupled with photodiode array detection method was developed for the amino acid analysis of Amur sturgeon (Acipenser schrenckii Brandt). The method uses minimal sample volume and automated online precolumn derivitization of amino acids with fluorescent 6-aminoquinolyl-carbamyl reagent. The chromatographic separation was achieved by UPLC, which used a column with 1.7 μm particle packing that enabled higher speed of analysis, peak capacity, greater resolution, and increased sensitivity. Amino acid derivatives obtained under optimal conditions were separated on a Waters UPLC BEH C(18) column with Acetonitrile-acetate buffer as mobile phase. Matrix effects were investigated and good linearities with correlation coefficients better than 0.9949 were obtained over a wide range of 5-1000 μmol/L for all amino acids. The simple sample preparation and minimal sample volume make the method useful for the quantitation of 17 amino acids in Amur sturgeon samples. It is concluded that a rapid and robust platform based on UPLC was established, and a total of 17 amino acids of Amur sturgeon were tentatively detected. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Miller, Tricia M; Poloyac, Samuel M; Anderson, Kacey B; Waddell, Brooke L; Messamore, Erik; Yao, Jeffrey K
2017-01-18
A rapid and sensitive method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed to simultaneously quantify hydroxyeicosatetraenoic (HETE), dihydroxyeicosatrienoic (DiHETrE), epoxyeicosatrienoic acid (EET), and prostaglandin metabolites of arachidonic acid in human plasma. Sample preparation consisted of solid phase extraction with Oasis HLB (30mg) cartridges for all metabolites. Separation of HETEs, EETs, and DiHETrEs was achieved on an Acquity UPLC BEH C18, 1.7µm (100×2.1mm) reversed-phase column (Waters Corp, Millford, MA) with negative electrospray ionization mass spectrometric detection. A second injection of the same extracted sample allowed for separation and assessment of prostaglandin metabolites under optimized UPLC-MS/MS conditions. Additionally, the endogenous levels of these metabolites in five different matrices were determined in order to select the optimal matrix for assay development. Human serum albumin was shown to have the least amount of endogenous metabolites, a recovery efficiency of 79-100% and a matrix effect of 71 - 100%. Linear calibration curves ranging from 0.416 to 66.67ng/ml were validated. Inter-assay and intra-assay variance was less than 15% at most concentrations. This method was successfully applied to quantify metabolite levels in plasma samples of healthy control subjects receiving niacin administration to evaluate the association between niacin administration and eicosanoid plasma level response. Published by Elsevier Ltd.
Boelaert, Jente; Schepers, Eva; Glorieux, Griet; Eloot, Sunny; Vanholder, Raymond; Lynen, Frédéric
2016-05-13
Asymmetric dimethylarginine (ADMA), an endogenous inhibitor of nitric oxide (NO) synthesis, and its structural isomer symmetric dimethylarginine (SDMA) are uremic toxins accumulating in chronic kidney disease (CKD) patients. The objective of this study was to develop and validate a robust UPLC-MS/MS method for the simultaneous determination of ADMA and SDMA in human serum. Chromatographic separation after butyl ester derivatization was achieved on an Acquity UPLC BEH C18 column, followed by tandem mass spectrometric detection. After validation, the applicability of the method was evaluated by the analysis of serum samples from 10 healthy controls and 77 CKD patients on hemodialysis (CKD5HD). Both ADMA (0.84 ± 0.19 µM vs. 0.52 ± 0.07 µM) and SDMA concentrations (2.06 ± 0.82 µM vs. 0.59 ± 0.13 µM) were significantly (p < 0.001) elevated in CKD5HD patients compared to healthy controls. In general, low degrees of protein binding were found for both ADMA and SDMA. In addition, an established commercially available ELISA kit was utilized on the same samples (n = 87) to compare values obtained both with ELISA and UPLC-MS/MS. Regression analysis between these two methods was significant (p < 0.0001) but moderate for both ADMA (R = 0.78) and SDMA (R = 0.72).
Determination and pharmacokinetic study of pirfenidone in rat plasma by UPLC-MS/MS.
Sun, Wei; Jiang, Zhe-li; Zhou, Lei; Chen, Rui-min; Wang, Zhe; Li, Wan-shu; Jiang, Shuo-min; Hu, Guo-xin; Chen, Rui-jie
2015-02-15
A rapid, sensitive and selective ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for the determination and pharmacokinetic investigation of pirfenidone in rat plasma. Sample preparation was accomplished through a simple one-step deproteinization procedure with 0.2 mL of acetonitrile to a 0.1 mL plasma sample. Plasma samples were separated by UPLC on an Acquity UPLC BEH C18 column using a mobile phase consisting of acetonitrile-0.1% formic acid in water with gradient elution. The total run time was 3.0 min and the elution of pirfenidone was at 1.39 min. The detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction-monitoring (MRM) mode using the respective transitions m/z 186.2→92.1 for pirfenidone and m/z 237.1→194.2 for carbamazepine (IS), respectively. The calibration curve was linear over the range of 5-2000 ng/mL with a lower limit of quantitation (LLOQ) of 5 ng/mL. Mean recovery of pirfenidone in plasma was in the range of 80.4-84.3%. Intra-day and inter-day precision were both <12.1%. This method was successfully applied in pharmacokinetic study after oral administration of 10.0mg/kg pirfenidone in rats. Copyright © 2015 Elsevier B.V. All rights reserved.
Kong, Weijun; Jin, Cheng; Xiao, Xiaohe; Zhao, Yanling; Liu, Wei; Li, Zulun; Zhang, Ping
2010-06-01
A fast ultra-performance liquid chromatography-evaporative light scattering detection (UPLC-ELSD) method was established for simultaneous quantification of seven components in natural Calculus bovis (C. bovis) and its substitutes or spurious breeds. On a Waters Acquity UPLC BEH C(18) column, seven analytes were efficiently separated using 0.2% aqueous formic acid-acetonitrile as the mobile phase in a gradient program. The evaporator tube temperature of ELSD was set at 100 degrees C with the nebulizing gas flow-rate of 1.9 L/min. The results showed that this established UPLC-ELSD method was validated to be sensitive, precise and accurate with the LODs of seven analytes at 2-11 ng, and the overall intra-day and inter-day variations less than 3.0%. The recovery of the method was in the range of 97.8-101.6%, with RSD less than 3.0%. Further results of PCA on the contents of seven investigated analytes suggested that compounds of cholic acid, deoxycholic acid and chenodeoxycholic acid or cholesterol should be added as chemical markers to UPLC analysis of C. bovis samples for quality control and to discriminate natural C. bovis sample and its substitutes or some spurious breeds, then normalize the use of natural C. bovis and ensure its clinical efficacy.
Avula, Bharathi; Wang, Yan-Hong; Smillie, Troy J; Khan, Ikhlas A
2009-03-01
A UPLC-UV/ELSD method has been developed for analysis of major triterpenoids and formononetin in ACTAEA RACEMOSA L. (family Ranunculaceae) samples. The best results were obtained with an Acquity UPLC BEH C18 (100 mmx2.1 mm, i. d., 1 microm) column system using gradient elution with a mobile phase consisting of water and acetonitrile:methanol (7:3) at a constant flow rate of 0.3 mL/min. Owing to their low UV absorption, the triterpene saponins were detected by evaporative light scattering. Within 5.5 minutes, three main triterpenoid glycosides [cimiracemoside A, 23- EPI-26-deoxyactein, and actein] and an isoflavonoid, formononetin, could be separated, with detection limits of 5, 5, 10, and 0.01 microg/mL, respectively. The method was successfully used to analyze different Actaea racemosa market products as well as to distinguish between two other ACTAEA species. There was a significant variability in the amounts of the selected triterpene glycosides for the products containing black cohosh and rhizomes of black cohosh. The isoflavone formononetin was not detected in the samples analyzed. LC-MS coupled with the electrospray ionization (ESI) interface method is described for the identification of formononetin and triterpenoid glycosides in plant samples and dietary supplements that claim to contain black cohosh and different species of Actaea.
Carlier, Mieke; Stove, Veronique; Roberts, Jason A; Van de Velde, Eric; De Waele, Jan J; Verstraete, Alain G
2012-11-01
There is an increasing interest in monitoring plasma concentrations of β-lactam antibiotics. The objective of this work was to develop and validate a rapid ultra-performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS) for simultaneous quantification of amoxicillin, ampicillin, cefuroxime, cefazolin, ceftazidime, meropenem, piperacillin, clavulanic acid and tazobactam. Sample clean-up included protein precipitation with acetonitrile and back-extraction of acetonitrile with dichloromethane. Six deuterated β-lactam antibiotics were used as internal standards. Chromatographic separation was performed on a Waters ACQUITY UPLC system using a BEH C(18) column (1.7 μm, 100 mm×2.1 mm) applying a binary gradient elution of water and acetonitrile both containing 0.1% formic acid. The total run time was 5.5 min. The developed method was validated in terms of precision, accuracy, linearity, matrix effect and recovery. The assay has now been successfully used to determine concentrations of amoxicillin/clavulanic acid, cefuroxime and meropenem in plasma samples from intensive care patients. Copyright © 2012 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula L N; Ramaiah, Parimi Atchuta
2012-01-01
A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one.
Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula. L. N.; Ramaiah, Parimi Atchuta
2012-01-01
A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one. PMID:22396907
Dobrinas, Maria; Choong, Eva; Noetzli, Muriel; Cornuz, Jacques; Ansermot, Nicolas; Eap, Chin B
2011-11-15
A sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of nicotine, its metabolites cotinine and trans-3'-hydroxycotinine and varenicline in human plasma was developed and validated. Sample preparation was realized by solid phase extraction of the target compounds and of the internal standards (nicotine-d4, cotinine-d3, trans-3'-hydroxycotinine-d3 and CP-533,633, a structural analog of varenicline) from 0.5 mL of plasma, using a mixed-mode cation exchange support. Chromatographic separations were performed on a hydrophilic interaction liquid chromatography column (HILIC BEH 2.1×100 mm, 1.7 μm). A gradient program was used, with a 10 mM ammonium formate buffer pH 3/acetonitrile mobile phase at a flow of 0.4 mL/min. The compounds were detected on a triple quadrupole mass spectrometer, operated with an electrospray interface in positive ionization mode and quantification was performed using multiple reaction monitoring. Matrix effects were quantitatively evaluated with success, with coefficients of variation inferior to 8%. The procedure was fully validated according to Food and Drug Administration guidelines and to Société Française des Sciences et Techniques Pharmaceutiques. The concentration range was 2-500 ng/mL for nicotine, 1-1000 ng/mL for cotinine, 2-1000 ng/mL for trans-3'-hydroxycotinine and 1-500 ng/mL for varenicline, according to levels usually measured in plasma. Trueness (86.2-113.6%), repeatability (1.9-12.3%) and intermediate precision (4.4-15.9%) were found to be satisfactory, as well as stability in plasma. The procedure was successfully used to quantify nicotine, its metabolites and varenicline in more than 400 plasma samples from participants in a clinical study on smoking cessation. Copyright © 2011 Elsevier B.V. All rights reserved.
Zhao, Ai-qin; Zhao, Ji-hong; Zhang, Shu-qing; Pan, Yong-yang; Huo, Xu-lei
2016-02-05
A rapid, sensitive and selective ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination and pharmacokinetic investigation of parthenolide in rat plasma. Sample preparation was accomplished through a simple one-step deproteinization procedure with 0.2mL of acetonitrile containing 30ng/mL of pirfenidone (IS), and to a 0.1mL plasma sample. Plasma samples were separated by UPLC on an Acquity UPLC BEH C18 column using a mobile phase consisting of acetonitrile-0.1% formic acid in water with gradient elution. The total run time was 3.0min and the elution of parthenolide was at 1.33min. The detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction-monitoring (MRM) mode using the respective transitions m/z 249.2→231.1 for parthenolide and m/z 186.2→92.1 for pirfenidone (IS), respectively. The calibration curve was linear over the range of 2.0-500ng/mL with a lower limit of quantitation (LLOQ) of 2.0ng/mL. Mean recovery of parthenolide in plasma was in the range of 78.2-86.6%. Intra-day and inter-day precision were both <8.3%. This method was successfully applied in pharmacokinetic study after oral and intravenous administration of parthenolide in rats. Copyright © 2015 Elsevier B.V. All rights reserved.
Siva Selva Kumar, M; Ramanathan, M
2016-02-01
A simple and sensitive ultra-performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of olanzapine (OLZ), risperidone (RIS) and 9-hydroxyrisperidone (9-OHRIS) in human plasma in vitro. The sample preparation was performed by simple liquid-liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP18 column maintained at 40°C. Quantification was performed on a photodiode array detector set at 277 nm and clozapine was used as internal standard (IS). OLZ, RIS, 9-OHRIS and IS retention times were found to be 0.9, 1.4, .1.8 and 3.1 min, respectively, and the total run time was 4 min. The method was validated for selectivity, specificity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 1-100 ng/mL for OLZ, RIS and 9-OHRIS. Intra- and inter-day precisions for OLZ, RIS and 9-OHRIS were found to be good with the coefficient of variation <6.96%, and the accuracy ranging from 97.55 to 105.41%, in human plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of RIS and 9-OHRIS in human plasma. Copyright © 2015 John Wiley & Sons, Ltd.
Ramanujam, N; Sivaselvakumar, M; Ramalingam, S
2017-11-01
A simple, sensitive and reproducible ultra-performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of polychlorinated biphenyl (PCB) 77 and PCB 180 in mouse plasma. The sample preparation was performed by simple liquid-liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP 18 column maintained at 35°C. Quantification was performed on a photodiode array detector set at 215 nm and PCB 101 was used as internal standard (IS). PCB 77, PCB 180, and IS retention times were 2.6, 4.7 and 2.8 min, respectively, and the total run time was 6 min. The method was validated for specificity, selectivity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 10-3000 ng/mL for PCB 77 and PCB 180. Intra- and inter-day precisions for PCBs 77 and 180 were found to be good with CV <4.64%, and the accuracy ranged from 98.90 to 102.33% in mouse plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of PCBs 77 and 180 in mouse plasma. Copyright © 2017 John Wiley & Sons, Ltd.
Xiao, Rong; Lin, Yan; Lei, Si-Min; Zhang, Ying; Huang, Jie; Xia, Bo-Hou; Li, Chun; Liao, Duan-Fang; Wu, Ping; Lin, Li-Mei
2017-06-01
To establish a content determination method for 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside (TSG) of the crude/processed root of Polygonum multiflorum from different habitats in China and set up the fingerprint by using UPLC. Various samples were pretreated by macro-porous resin. Then UPLC analysis was performed on Waters ACQUITY UPLC@BEH C18 chromatographic column (2.1 mm×50 mm, 1.7 μm) at (25±5) ℃. A binary gradient elution system was composed of acetonitrile (phase A) and 0.5% acetic acid solution (phase B). Detection was performed at the wavelength of 254 nm, and the mobile flow rate was set at 0.3 mL•min⁻¹. Results showed that the yield of extraction of the 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside from root of P. multiflorum was all over 25.0% after macro-porous resin separation; an exclusive UPLC fingerprint method of the crude/processed root of P. multiflorum from different habitats was successfully set up and 17 chromatographic peaks were calibrated. Cluster analysis can not entirely distinguish the crude one from the processed one, while principal component analysis absolutely can. 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside is the composition that has largest differences in variable importance in projection (VIP) between crude and processed root of P. multiflorum. The separating method can gain high-purity 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside, and the determination method is simple, sensitive, reliable and can be used in fast identifying the crude/processed root of P. multiflorum or as a method for overall quality control of root of P. multiflorum. Copyright© by the Chinese Pharmaceutical Association.
[Rapidly identify oligosaccharides in Morinda officinalis by UPLC-Q-TOF-MSE].
Hao, Qing-Xiu; Kang, Li-Ping; Zhu, Shou-Dong; Yu, Yi; Hu, Ming-Hua; Ma, Fang-Li; Zhou, Jie; Guo, Lan-Ping
2018-03-01
In this paper, an approach was applied for separation and identification of oligosaccharides in Morinda officinalis How by Ultra performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS) with collision energy. The separation was carried out on an ACQUITY UPLC BEH Amide C₁₈(2.1mm×100 mm,1.7 μm) with gradient elution using acetonitrile(A) and water(B) containing 0.1% ammonia as mobile phase at a flow rate of 0.2 mL·min⁻¹. The column temperature was maintained at 40 °C. The information of accurate mass and characteristic fragment ion were acquired by MSE in ESI negative mode in low and high collision energy. The chemical structures and formula of oligosaccharides were obtained and identified by the software of UNIFI and Masslynx 4.1 based on the accurate mass, fragment ions, neutral losses, mass error, reference substance, isotope information, the intensity of fragments, and retention time. A total of 19 inulin oligosaccharide structures were identified including D(+)-sucrose, 1-kestose, nystose, 1F-fructofuranosyl nystose and other inulin oligosaccharides (DP 5-18). This research provided important information about the inulin oligosaccharides in M. officinalis. The results would provide scientific basis for innovative utilization of M. officinalis. Copyright© by the Chinese Pharmaceutical Association.
Qian, Chang-Min; Song, Zhao-Hui; Zhang, Lan-Lan; Zhou, Shui-Ping; Feng, Feng
2013-09-01
An ultra performance liquid chromatography (UPLC) method was established and validated to simultaneously determine the contents of six aconitum alkaloids in mother, daughter and fibrous roots of 19 batches of Aconitum carmichaelii from Sichuan province. The separation of the six alkaloids was achieved on a ACQUITY UPLC BEH C18 (2.1 mm x 100 mm, 1.7 microm) column at 40 degrees C with a mobile phase consisting of acetonitrile in 30 mmol x L(-1) ammonium acetate buffer solution (adjusted to pH 10.0 with aqueous ammonia) in gradient mode. The data and plots showed that the six aconitum alkaloids have different distributions. Four aconitum alkaloids were almost same in mother and daughter root except benzoylmesaconine and mesaconitine, while the fibrous root differed from the other two roots. The comparisons of significant differences of six aconitum alkaloids between the mother and daughter roots definitely demonstrated that benzoylmesaconine and mesaconitine were the representative components. The 38 detecting samples were classified as two clusters by hierarchical clustering analysis (HCA) and principle component analysis (PCA), the results indicated that the mother root was different from the daughter root on chemical material basis. The study might contribute to the reasonable clinical application of A. carmichaelii.
Hedaya, Mohsen A; Thomas, Vidhya; Abdel-Hamid, Mohamed E; Kehinde, Elijah O; Phillips, Oludotun A
2017-01-01
Linezolid is the first approved oxazolidinone antibacterial agent, whereas PH027 is a novel compound of the same class that exhibits good in vitro antibacterial activity. The objective of this study was to develop an UPLC-MS/MS assay for the analysis of linezolid and PH027 in plasma and to apply the method for comparative pharmacokinetic and tissue distribution studies of both compounds. Plasma samples and calibrators were extracted with diethyl ether after addition of the internal standard solution. After evaporation of the ether layer, the residue was reconstituted in mobile phase and injected into UPLC-MS/MS. The mobile phase consisted of 2mM ammonium acetate buffer solution and acetonitrile (70:30) at a flow rate of 0.2ml/min. Separation was achieved using UPLC BEH C 18 column, and quantitative determination of the analytes was performed using multiple-reaction monitoring (MRM) scanning mode. The method was validated by analyzing quality control tissue homogenate samples, and was applied to analyze tissue homogenate samples obtained following IV injections of linezolid and PH027 in rabbits. The developed UPLC-MS/MS method was linear in the concentration range of 50-5000ng/ml. Validation of the method proved that the method's precision, selectivity and stability were all within the acceptable limits. Linezolid and PH027 concentrations were accurately determined in the quality control tissue homogenate samples, and analysis of samples obtained following IV administration of the two compounds showed that the tissue to plasma concentration ratio of PH027 was higher than that of linezolid probably due to its higher lipophilicity. The developed UPLC-MS/MS method for the analysis of linezolid and PH027 in rabbit's plasma can accurately determine the concentrations of these compounds in different tissues. Copyright © 2016 Elsevier B.V. All rights reserved.
Determination of atmospheric organosulfates using HILIC chromatography with MS detection
NASA Astrophysics Data System (ADS)
Hettiyadura, A. P. S.; Stone, E. A.; Kundu, S.; Baker, Z.; Geddes, E.; Richards, K.; Humphry, T.
2014-12-01
Measurements of organosulfates in ambient aerosols provide insight to the extent of secondary organic aerosol (SOA) formation from mixtures of biogenic gases and anthropogenic pollutants. Organosulfates have, however, proved analytically challenging to measure. This study presents a sensitive new analytical method for the quantification of organosulfates based upon ultra-performance liquid chromatography with negative electrospray ionization mass spectrometry (UPLC-ESI-MS/MS). The separation is based upon hydrophilic interaction liquid chromatography (HILIC) with an amide stationary phase that provides excellent retention of carboxy-organosulfates and methyltetrol-derived organosulfates. The method is validated using six model compounds: methyl sulfate, ethyl sulfate, benzyl sulfate, hydroxyacetone sulfate, lactic acid sulfate, and glycolic acid sulfate. A straightforward protocol for preparation of highly pure organosulfate potassium salts for use as quantification standards is presented. This highly efficient method of separating and quantifying organosulfates is used to evaluate the efficiency and precision of two methods of ambient PM2.5 sample extraction. Spike recoveries averaged 98 ± 8% for extraction by sonication and 98 ± 10% for extraction by rotary-shaking. Sonication was determined to be the superior method for its better precision. Analysis of ambient PM2.5 samples collected 10-11 July 2013 in Centreville, AL, USA during the Southeast Atmosphere Study (SAS) confirms the presence of hydroxyacetone sulfate in ambient aerosol for the first time. Glycolic acid sulfate was the most abundant compound measured (ranging 8-14 ng m-3), followed by hydroxyl acetone sulfate (2.7-5.8 ng m-3) and lactic acid sulfate (1.4-2.9 ng m-3). Trace amounts of methyl sulfate were detected, while ethyl sulfate and benzyl sulfate were not detected. Future research will focus on the development of additional organosulfates standards, expansion of this UPLC-MS/MS to include more target molecules, and the application of this method to assess temporal variations in organosulfates in ambient environments.
Shi, Zhihong; Li, Zhimin; Zhang, Shulan; Fu, Hongna; Zhang, Hongyi
2015-09-01
Based on the phase separation phenomenon of acetonitrile-water system at subzero temperature, a subzero-temperature liquid-liquid extraction coupled with ultra-performance liquid chromatography tandem quadrupole mass spectrometry : UPLC-MS-MS) method was developed for the simultaneous determination of 12 bioactive components in Gegen-Qinlian decoction. After optimization, the extraction conditions were set as follows: 3.0 mL of aqueous sample solution (pH 5.86) was extracted with 2 mL of acetonitrile at -35°C for 35 min. The separated acetonitrile phase was diluted 10-fold with water before UPLC-MS-MS analysis. Separation was performed on a Waters ACQUITY UPLC(®)BEH C18 column (2.1 × 100 mm i.d., 1.7 µm) with ammonium formate buffer solution (20 mmol L(-1), pH 3.2, adjusted by formic acid) and acetonitrile as mobile phase with gradient elution. Twelve target components could be separated within 10 min and quantified in multiple reaction monitoring mode, both positive and negative ionization modes were employed. Limits of detection were in the range of 0.0003-0.0451 μg mL(-1). Relative standard deviation values for intra- and interday precision were <2.71 and 8.94%, respectively. The established method provides a simple and effective framework for the quality control of Gegen-Qinlian decoction and related traditional Chinese medicinal preparations. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Li-Bo, Dai; Miao, Yan; Huan-De, Li; Ping-Fei, Fang; Feng, Wang; Yang, Deng
2013-09-01
A simple and sensitive analytical method based on ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been developed for determination of moclobemide in human brain cell monolayer as an in vitro model of blood-brain barrier. Brucine was employed as the internal standard. Moclobemide and internal standard were extracted from cell supernatant by ethyl acetate after alkalinizing with sodium hydroxide. The UPLC separation was performed on an Acquity UPLC(TM) BEH C18 column (50 × 2.1 mm, 1.7 µm, Waters, USA) with a mobile phase consisting of methanol-water (29.5:70.5, v/v); the water in the mobile phase contained 0.05% ammonium acetate and 0.1% formic acid. Detection of the analytes was achieved using positive ion electrospray via multiple reaction monitoring mode. The mass transitions were m/z 269.16 → 182.01 for moclobemide and m/z 395.24 → 324.15 for brucine. The extraction recovery was 83.0-83.4% and the lower limit of quantitation (LLOQ) was 1.0 ng/mL for moclobemide. The method was validated from LLOQ to 1980 ng/mL with a coefficient of determination greater than 0.999. Intra- and inter-day accuracies of the method at three concentrations ranged from 89.1 to 100.9% for moclobemide with precision of 1.1-9.6%. This validated method was successfully applied to bidirectional transport study of moclobemide blood-brain barrier permeability. Copyright © 2013 John Wiley & Sons, Ltd.
[Content determination of twelve major components in Tibetan medicine Zuozhu Daxi by UPLC].
Qu, Yan; Li, Jin-hua; Zhang, Chen; Li, Chun-xue; Dong, Hong-jiao; Wang, Chang-sheng; Zeng, Rui; Chen, Xiao-hu
2015-05-01
A quantitative analytical method of ultra-high performance liquid chromatography (UPLC) was developed for simultaneously determining twelve components in Tibetan medicine Zuozhu Daxi. SIMPCA 12.0 software was used a principal component analysis PCA) and partial small squares analysis (PLSD-DA) on the twelve components in 10 batches from four pharmaceutical factories. Acquity UPLC BEH C15 column (2.1 mm x 100 mm, 1.7 µm) was adopted at the column temperature of 35 °C and eluted with acetonitrile (A) -0.05% phosphate acid solution (B) as the mobile phase with a flow rate of 0. 3 mL · min(-1). The injection volume was 1 µL. The detection wavelengths were set at 210 nm for alantolactone, isoalantolactone and oleanolic; 260 nm for trychnine and brucine; 288 nm for protopine; 306 nm for protopine, resveratrol and piperine; 370 nm for quercetin and isorhamnetin. The results showed a good separation among index components, with a good linearity relationship (R2 = 0.999 6) within the selected concentration range. The average sample recovery rates ranged between 99.44%-101.8%, with RSD between 0.37%-1.7%, indicating the method is rapid and accurate with a good repeatability and stability. The PCA and PLSD-DA analysis on the sample determination results revealed a great difference among samples from different pharmaceutical factories. The twelve components included in this study contributed significantly to the quantitative determination of intrinsic quality of Zuozhu Daxi. The UPLC established for to the quantitative determination of the twelve components can provide scientific basis for the comprehensive quality evaluation of Zuozhu Daxi.
Wu, Xiao; Huang, Yue; Sun, Jinghan; Wen, Yongqing; Qin, Feng; Zhao, Longshan; Xiong, Zhili
2018-01-01
A HILIC-UHPLC-MS/MS untargeted urinary metabonomic method combined with quantitative analysis of five potential polar biomarkers in rat urine was developed and validated, to further understand the anti-osteoporosis effect of Gushudan(GSD) and its mechanism on prednisolone-induced osteoporosis(OP) rats in this study. The metabolites were separated and identified on Waters BEH HILIC (2.1mm×100mm, 1.7μm) column using the Waters ACQUITY™ ultra performance liquid chromatography system (Waters Corporation, Milford, USA) coupled with a Micromass Quattro Micro™ API mass spectrometer (Waters Corp, Milford, MA, USA). Principal component analysis (PCA) was used to identify potential biomarkers. Primary potential polar biomarkers including creatinine, taurine, betaine, hypoxanthine and cytosine, which were related to energy metabolism, lipid metabolism and amino acid metabolism, were found in the untargeted metabonomic research. Moreover, these targeted biomarkers were further separated and quantified in multiple-reaction monitoring (MRM) with positive ionization mode, using tinidazole as internal standard (I.S.). Good linearities (r>0.99) were obtained for all the analytes with the low limit of quantification from 1.00 to 12.8μg/mL. The relative standard deviation (RSD) of the intra-day and inter-day precisions were within 15.0% and the accuracy ranged from -14.3% to 13.5%. The recovery was more than 85.0%. And the validated method was successfully applied to investigate the urine samples of the control group, prednisolone-induced osteoporosis model group and Gushudan-treatment group in rats. Compared to the control group, the level of creatinine, taurine, betaine, hypoxanthine and cytosine in the model group revealed a significant decrease trend (p<0.05), while the Gushudan-treatment group showed no statistically differences by an independent sample t-test. This paper provided a better understanding of the therapeutic effect and mechanism of GSD on prednisolone-induced osteoporosis rats. Copyright © 2017. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Tolstikov, Vladimir V.
Analysis of the metabolome with coverage of all of the possibly detectable components in the sample, rather than analysis of each individual metabolite at a given time, can be accomplished by metabolic analysis. Targeted and/or nontargeted approaches are applied as needed for particular experiments. Monitoring hundreds or more metabolites at a given time requires high-throughput and high-end techniques that enable screening for relative changes in, rather than absolute concentrations of, compounds within a wide dynamic range. Most of the analytical techniques useful for these purposes use GC or HPLC/UPLC separation modules coupled to a fast and accurate mass spectrometer. GC separations require chemical modification (derivatization) before analysis, and work efficiently for the small molecules. HPLC separations are better suited for the analysis of labile and nonvolatile polar and nonpolar compounds in their native form. Direct infusion and NMR-based techniques are mostly used for fingerprinting and snap phenotyping, where applicable. Discovery and validation of metabolic biomarkers are exciting and promising opportunities offered by metabolic analysis applied to biological and biomedical experiments. We have demonstrated that GC-TOF-MS, HPLC/UPLC-RP-MS and HILIC-LC-MS techniques used for metabolic analysis offer sufficient metabolome mapping providing researchers with confident data for subsequent multivariate analysis and data mining.
Fan, Sai; Zou, Jianhong; Li, Liping; Zhang, Nan; Liu, Wei; Li, Bing; Zhao, Xudong; Wu, Guohua; Xue, Ying; Zhao, Rong
2014-09-01
An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed to identify and determine 11 industrial antioxidants in the aqueous simulants. A ProElut PLS SPE column was used for the enrichment, and an ACQUITY UPLC BEH C18 UPLC column (100 mm x 2.1 mm, 1.7 μm) was used for separation by the gradient elution with pure water and acetonitrile as the mobile phases. The MS/MS detection was performed with an electrospray ionization (ESI) source in negative mode. The external standard method was used for quantitation in the present study. The linear ranges of the 11 analytes were from 5.0 to 100 μg/L. The coefficients of correlation were greater than 0.995. The recoveries of blank aqueous simulants fortified with the 11 analytes at the levels of 5.0, 10.0 and 20.0 μg/L were 61.4% to 109.4% with the relative standard deviations varied from 3.9% to 18.2% (n = 6). The LODs and LOQs of the 11 analytes in aqueous simulants were 0.2-1.0 μg/L and 0.5-3.0 μg/L, respectively. This method is highly sensitive and accurate, and can be applied to the determination of the 11 trace industrial antioxidants in the aqueous simulants.
Qiu, Xiangjun; Lou, Dan; Su, Ding; Liu, Zebin; Gao, Pengtao; Zhang, Nan-sheng
2015-06-15
An ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to determine acetaminophen (AAP) and dihydrocodeine (DHC) in human plasma simultaneously. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard midazolam were separated on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 151.2→110.0 and m/z 302.3→199.2 were used to quantify for AAP and DHC, respectively. The linearity of this method was found to be within the concentration range of 50-10000ng/mL for AAP, and 1-100ng/mL for DHC in human plasma, respectively. The lower limit of quantification (LLOQ) was 50ng/mL and 1ng/mL for AAP and DHC in human plasma, respectively. The relative standard deviations (RSD) of intra and inter precision were less than 10% for both AAP and DHC. The analysis time of per sample was 1.0min. The developed and validated method was successfully applied to a pharmacokinetic study of AAP (500mg) with DHC (20mg) capsule in Chinese healthy volunteers (N=20). Copyright © 2015 Elsevier B.V. All rights reserved.
Zhang, Ming; Tang, Fangliang; Yu, Yayun; Chen, Feng; Xu, Jianfen; Ye, Yonggen
2014-05-01
A high-throughput detection method has been developed for the determination of sixteen perfluorinated organic compounds (PFCs) in surface water by solid phase extraction-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (SPE-UPLC-ESI-MS/MS). The water samples were concentrated and purified through WAX solid phase extraction cartridges. The UPLC separation was performed on an ACQUITY UPLC BEH C18 column utilizing a gradient elution program of methanol (containing 2 mmol/L ammonium acetate) and water (containing 2 mmol/L ammonium acetate) as the mobile phases at a flow rate of 0.4 mL/min. The MS/MS detection was performed under negative electrospray ionization ( ESI ) in multiple reaction monitoring (MRM) mode. Good linearities were observed in the range of 0.5-100 gg/L or 1.0 - 100 microg/L with correlation coefficients from 0.998 7 to 0.999 9. The limits of detection (LODs) for the sixteen perfluorinated organic compounds were in the range of 0.06-0.46 ng/L. The recoveries ranged from 67.6% to 103% with the relative standard deviations between 2.94% and 12.0%. This method was characterized by high sensitivity and precision, extensive range and high speed, and can be applied for the analysis of PFC contaminants in surface water.
Pharmacokinetic study of indocyanine Green after intravenous administration by UPLC-MS/MS.
Chen, Yu; Chen, Dongxin; Hu, Wenhao; Lin, Guanyang; Huang, Shiyong
2015-01-01
Indocyanine Green is widely used in medical diagnosis and to evaluate liver function and other regional blood flows in clinical application or animal experiments. In this work, a sensitive and selective ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determination of Indocyanine Green in rat plasma was developed and validated. After addition of rutin as an internal standard (IS), protein precipitation by acetonitrile-methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm) with 0.1% formic acid and acetonitrile as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reactions monitoring (MRM) mode was used for quantification using target fragment ions m/z 753.4→330.2 for Indocyanine Green, and m/z 611.1→303.1 for IS. Calibration plots were linear throughout the range 20-5000 ng/mL for Indocyanine Green in rat plasma. Mean recoveries of Indocyanine Green in rat plasma ranged from 79.5% to 85.4%. RSD of intra-day and inter-day precision were both < 12%. The accuracy of the method was between 95.9% and 113.9%. The method was successfully applied to pharmacokinetic study of Indocyanine Green after intravenous administration.
Pharmacokinetic study of indocyanine Green after intravenous administration by UPLC-MS/MS
Chen, Yu; Chen, Dongxin; Hu, Wenhao; Lin, Guanyang; Huang, Shiyong
2015-01-01
Indocyanine Green is widely used in medical diagnosis and to evaluate liver function and other regional blood flows in clinical application or animal experiments. In this work, a sensitive and selective ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determination of Indocyanine Green in rat plasma was developed and validated. After addition of rutin as an internal standard (IS), protein precipitation by acetonitrile-methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm) with 0.1% formic acid and acetonitrile as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reactions monitoring (MRM) mode was used for quantification using target fragment ions m/z 753.4→330.2 for Indocyanine Green, and m/z 611.1→303.1 for IS. Calibration plots were linear throughout the range 20-5000 ng/mL for Indocyanine Green in rat plasma. Mean recoveries of Indocyanine Green in rat plasma ranged from 79.5% to 85.4%. RSD of intra-day and inter-day precision were both < 12%. The accuracy of the method was between 95.9% and 113.9%. The method was successfully applied to pharmacokinetic study of Indocyanine Green after intravenous administration. PMID:26629038
Gong, Zhilong; Chandler, Kiresha; Webster, Stephen; Kerley, Remy; Buist, Susan; McCort-Tipton, Melanie
2012-03-15
We report for the first time an ultra performance liquid chromatographic method with tandem mass spectrometric detection (UPLC/MS/MS) for the determination of norethindrone alone in human plasma over the concentration range of 50.0-25000 pg mL(-1) using a sample volume of 0.250 mL. Norethindrone and its internal standard (ISTD), norethindrone-(13)C(2), were extracted from human plasma by supported liquid extraction (SLE). After evaporation of the organic solvent, samples were reconstituted and analyzed on an UPLC/MS/MS system. The UPLC system used a Waters BEH C18 (100 mm × 2.1mm, 1.7 μm) column with mobile phase A of 0.05% formic acid in water:acetonitrile (65:35, v/v) and mobile phase B of 0.05% formic acid in methanol:acetonitrile (50:50, v/v). The flow rate was 0.500 mL min(-1). The method was fully validated. The inter-run accuracy and precision at the lower limit of quantitation (LLOQ), low, mid and high quality control (QC) concentration levels were 99.2-108.4% with a <8.1% CV (coefficient of variation), respectively. The validated method has been successfully applied to analysis of thousands of pharmacokinetic samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Rezk, Mamdouh R; Badr, Kamal A
2018-07-01
A robust, rapid and sensitive UPLC-MS/MS method has been developed, optimized and validated for the determination of amlodipine (AML) and atorvastatin (ATO) in human plasma using eplerenone as an internal standard (IS). Multiple-reaction monitoring in positive electrospray ionization mode was utilized in Xevo TQD LC-MS/MS. Double extraction was used in sample preparation using diethyl ether and ethyl acetate. The prepared samples were analyzed using an Acquity UPLC BEH C 18 (50 × 2.1 mm, 1.7 μm) column. Ammonium formate and acetonitrile, pumped isocraticaly at a flow rate of 0.25 mL/min, were used as a mobile phase. Method validation was done as per the US Food and Drug Administration guidelines. Linearity was achieved in the range of 0.1-10 ng/mL for AML and 0.05-50 ng/mL for ATO. Intra-day and inter-day accuracy and precision were calculated and found to be within the acceptable range. A short run time, of <1.5 min, permits analysis of a large number of plasma samples per batch. The developed and validated method was applied to estimate AML and ATO in a bioequivalence study in healthy human volunteers. Copyright © 2018 John Wiley & Sons, Ltd.
Yao, Xin; Zhou, Guisheng; Tang, Yuping; Li, Zhenhao; Su, Shulan; Qian, Dawei; Duan, Jin-Ao
2013-03-07
A sensitive and accurate ultra-performance liquid chromatography coupled with triple quadrupole mass (UPLC-MS/MS) method was developed for the determination of quercetin-3-O-β-D-glucopyranoside-(4→1)-α-L-rhamnoside (QGR) in rat plasma using rutin as internal standard. Chromatographic separation was achieved on a Acquity BEH C18 column (100 mm × 2.1 mm, 1.7 μm) with a gradient elution of acetonitrile and 0.10% formic acid (v/v) at a flow rate of 0.4 mL/min. QGR and rutin were detected using electrospray negative ionization mass spectrometry in the multiple reaction monitoring (MRM) mode. The method demonstrated good linearity and did not show any endogenous interference with the QGR and rutin peaks. This method was successfully applied to a pharmacokinetic study of QGR in rats after intravenous (20 mg/kg) and oral (40 mg/kg) administration, and the results showed that the compound was poorly absorbed, with an absolute bioavailability of approximately 3.41%.
Rao, Dantu Durga; Satyanarayana, N V; Malleswara Reddy, A; Sait, Shakil S; Chakole, Dinesh; Mukkanti, K
2010-02-05
A novel stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the determination of purity of desloratadine in presence of its impurities and forced degradation products. The method was developed using Waters Aquity BEH C18 column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 280nm. The run time was 8min within which desloratadine and its five impurities were well separated. Desloratadine was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Desloratadine was found to degrade significantly in oxidative and thermal stress conditions and stable in acid, base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, thus proved the stability-indicating power of the method. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of desloratadine in pharmaceutical dosage forms.
Shibata, Mai; Hashi, Sachiyo; Nakanishi, Haruka; Masuda, Satohiro; Katsura, Toshiya; Yano, Ikuko
2012-12-01
The purpose of this study was to develop an ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method of 22 antiepileptics for routine therapeutic monitoring. The antiepileptics used in the analyses were carbamazepine, carbamazepine-10,11-epoxide, clobazam, N-desmethylclobazam, clonazepam, diazepam, N-desmethyldiazepam, ethosuximide, felbamate, gabapentin, lamotrigine, levetiracetam, N-desmethylmesuximide, nitrazepam, phenobarbital, phenytoin, primidone, tiagabine, topiramate, valproic acid, vigabatrin and zonisamide. After protein precipitation of 50 μL plasma with methanol, the supernatant was diluted with water or was evaporated to dryness and reconstituted with mobile phase in the case of benzodiazepines. Separation was achieved on an Acquity UPLC BEH C₁₈ column with a gradient mobile phase of 10 mm ammonium acetate containing 0.1% formic acid and methanol at a flow rate of 0.4 mL/min. An Acquity TQD instrument in multiple reaction monitoring mode with ion mode switching was used for detection. All antiepileptics were detected and quantified within 10 min, with no endogenous interference. All the calibration curves showed good linearity in the therapeutic range (r² < 0.99). The precision and accuracy values for intra- and inter-assays were within ±15% except for phenobarbital and tiagabine. A good correlation was observed between the concentration of clinical samples measured by the new method described here and the conventional methods. The values of carbamazepine and phenytoin by UPLC-MS/MS were lower than those detected by the immunoassays, which might be caused by the cross-reaction of antibodies with their metabolites. In conclusion, we developed a simple and selective UPLC-MS/MS method suitable for routine therapeutic monitoring of antiepileptics. Copyright © 2012 John Wiley & Sons, Ltd.
Pandey, Renu; Chandra, Preeti; Srivastava, Mukesh; Mishra, D K; Kumar, Brijesh
2015-01-01
Ocimum sanctum L., with phenolic acids, flavonoids, propenyl phenols and terpenoids as active pharmacological constituents, is a popular medicinal herb and is present as an ingredient in many herbal formulations. Therefore, development of a reliable analytical method for simultaneous determination of the pharmacologically active constituents of O. sanctum is of high importance. To develop and validate a new, rapid, sensitive and selective UPLC-ESI/MS/MS method for simultaneous determination of 23 bioactive markers including phenolic acids, flavonoids, propenyl phenol and terpenoid in the leaf extract and marketed herbal formulations of O. sanctum. An UPLC-ESI/MS/MS method using negative electrospray ionisation (ESI) in multiple-reaction-monitoring (MRM) mode was used for simultaneous determination. Chromatographic separation was achieved on an Acquity UPLC BEH C18 -column using a gradient elution with 0.1% formic acid in water and 0.1% formic acid in acetonitrile. Principal component analysis (PCA) was applied to correlate and discriminate eight geographical collections of O. sanctum based on quantitative data of the analytes. The developed method was validated as per International Conference on Harmonization guidelines and found to be accurate, with overall recovery in the range 95.09-104.84% (RSD ≤ 1.85%), precise (RSD ≤ 1.98%) and linear (r(2) ≥ 0.9971) over the concentration range of 0.5-1000 ng/mL. Ursolic acid was found to be the most abundant marker in all the samples investigated, except for the marketed tablet. The method established is simple, rapid and sensitive, hence it can be reliably utilised for the quality control of O. sanctum and derived herbal formulations. Copyright © 2015 John Wiley & Sons, Ltd.
Zheng, Mengjing; Gu, Shubo; Chen, Jin; Luo, Yongli; Li, Wenqian; Ni, Jun; Li, Yong; Wang, Zhenlin
2017-06-15
A method to determine the lignin monomers (p-hydroxybenzaldehyde, vanillin and syringaldehyde) in plant cell wall of wheat internode was developed and validated using a high-throughput nitrobenzene oxidation step and ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) for quantification. UPLC analyses were carried out using an reversed phase C 18 column (ACQUITY UPLC BEH, 1.7μm, 2.1×100mm) and gradient elution with water and acetonitrile. This method was completely validated in terms of analyzing speed, linearity, sensitivity, limits of detection (LODs) and limits of quantification (LOQs).The three lignin monomers were successfully separated within 6min and only 2min were required to regain its equilibrium. The method linearity with regression coefficients values (R2) greater than 0.997. Additionally, LODs ranged from 0.21 to 0.89μgL -1 and LOQs ranged from 0.69 to 2.95μgL -1 . The applicability of this analytical approach for determining the three lignin monomers was confirmed by the successful analysis of real samples of wheat stem internodes. The nitrobenzene oxidation method was used for the analysis of lignin monomers. We have optimized the treatment temperature (170°C, 1h) and realized the high-throughput using the microwave digestion instrument. Recovery of this extraction method ranged from 68.4% to 77.7%. The analysis result showed that the guaiacyl unit (G) was the major component of lignin and there was a higher content of the syringyl unit (S) than that of the hydroxybenzyl unit (H). Copyright © 2017. Published by Elsevier B.V.
Wang, Xiaoyang; Wang, Mi; Zhang, Keyu; Hou, Ting; Zhang, Lifang; Fei, Chenzong; Xue, Feiqun; Hang, Taijun
2018-06-01
A reliable UPLC-MS/MS method with high sensitivity was developed and validated for the determination of virginiamycin M1 in muscle, fat, liver, and kidney samples of chicken and swine. Analytes were extracted using acetonitrile and extracts were defatted by N-hexane. Chromatographic separation was performed on a BEH C18 liquid chromatography column. The analytes were then detected using triplequadrupole mass spectrometry in positive electrospray ionization and multiple reaction monitoring mode. Calibration plots were constructed using standard working solutions and showed good linearity. Limits of quantification ranged from 2 to 60 ng mL -1 . Copyright © 2018 Elsevier Ltd. All rights reserved.
2015-01-01
Metabolic profiling studies aim to achieve broad metabolome coverage in specific biological samples. However, wide metabolome coverage has proven difficult to achieve, mostly because of the diverse physicochemical properties of small molecules, obligating analysts to seek multiplatform and multimethod approaches. Challenges are even greater when it comes to applications to tissue samples, where tissue lysis and metabolite extraction can induce significant systematic variation in composition. We have developed a pipeline for obtaining the aqueous and organic compounds from diseased arterial tissue using two consecutive extractions, followed by a different untargeted UPLC-MS analysis method for each extract. Methods were rationally chosen and optimized to address the different physicochemical properties of each extract: hydrophilic interaction liquid chromatography (HILIC) for the aqueous extract and reversed-phase chromatography for the organic. This pipeline can be generic for tissue analysis as demonstrated by applications to different tissue types. The experimental setup and fast turnaround time of the two methods contributed toward obtaining highly reproducible features with exceptional chromatographic performance (CV % < 0.5%), making this pipeline suitable for metabolic profiling applications. We structurally assigned 226 metabolites from a range of chemical classes (e.g., carnitines, α-amino acids, purines, pyrimidines, phospholipids, sphingolipids, free fatty acids, and glycerolipids) which were mapped to their corresponding pathways, biological functions and known disease mechanisms. The combination of the two untargeted UPLC-MS methods showed high metabolite complementarity. We demonstrate the application of this pipeline to cardiovascular disease, where we show that the analyzed diseased groups (n = 120) of arterial tissue could be distinguished based on their metabolic profiles. PMID:25664760
Joo, Kyung-Mi; Han, Ji Yeon; Son, Eui Dong; Nam, Gae-Won; Chung, Han Young; Jeong, Hye-Jin; Cho, Jun-Cheol; Lim, Kyung-Min
2012-05-15
A rapid, sensitive and specific hydrophilic interaction liquid chromatography coupled to tandem mass spectrometric (HILIC-MS/MS) method for the simultaneous determination of pyroglutamic acid, cis- and trans-urocanic acid in human skin stratum corneum (SC) were developed and validated. This method was carried out without derivatization or addition of ion-pair additives in mobile phase. The analytes were extracted by PBS buffer solution and analyzed using an electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode. Chromatographic separation was performed on an AQUITY UPLC amide column using gradient elution with the mobile phase of water and acetonitrile. The standard curves were linear over the concentration range of 1.0-250 ng/mL with a correlation coefficient higher than 0.999 with an LLOQ of 0.5 ng/mL. The lower limits of detection (LLOD) of these analytes were lower than 0.2 ng/mL. The intra- and inter-day precisions were measured to be below 7.7% and accuracies were within the range of 94.3-102.6%. The validated method was successfully applied to determine the level of pyroglutamic acid and cis-/trans-urocanic acid in the SC samples from forearm and forehead region of 19 human volunteers. Copyright © 2012 Elsevier B.V. All rights reserved.
Vanol, Pravin G; Singhal, Puran; Shah, Priyanka A; Shah, Jaivik V; Shrivastav, Pranav S; Sanyal, Mallika
2016-08-01
A rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method is described for determination of letrozole in human plasma. Following solid phase extraction (SPE) of letrozole and letrozole-d4 on Orochem DVB-LP cartridges, chromatography was performed on Acquity UPLC BEH C 18 (50 mm×2.1 mm, 1.7 µm) column using methanol-0.1% formic acid in water (85:15, v/v) as the mobile phase. Detection was carried out on a triple quadrupole mass spectrometer with an electrospray source, operated under positive ionization mode. Quantitation of letrozole and letrozole-d4 was done using multiple reaction monitoring (MRM) following the transitions at m/z 286.2→217.0 and m/z 290.2→221.0, respectively. The calibration plots were linear through the concentration range of 0.10-100 ng/mL ( r 2 ≥0.9990) using 100 µL human plasma. The extraction recovery of letrozole ranged from 94.3% to 96.2% and the intra-batch and inter-batch precision was ≤5.2%. The method was successfully applied to a bioequivalence study of letrozole after oral administration of 2.5 mg tablet formulation to 16 healthy postmenopausal Indian women. The assay reproducibility was also established through incurred sample reanalysis (ISR) of 74 subject samples.
Geng, Peiwu; Luo, Jun; Weng, Ziwei; Fan, Zhehua; Zhang, Bin; Ma, Jianshe; Wang, Xianqin; Zhang, Meiling
2018-05-03
The purpose of this study was to develop an ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) method to determine armepavine in mouse blood. Nuciferine was used as internal standard. Chromatographic separation was performed on a UPLC BEH (2.1 × 50 mm, 1.7 μm) column with a gradient elution of acetonitrile and 10 mmol/L ammonium acetate solution (containing 0.1% formic acid). The quantitative analysis was conducted in multiple reaction monitoring mode with m/z 314.1 → 106.9 for armepavine and m/z 296.2 → 265.1 for nuciferine. Calibration curves were linear (r > 0.995) over the concentration range 1-1000 ng/mL in mouse blood with a lowest limit of quantitation of 1 ng/mL. The intra- and inter-day precisions of armepavine in mouse were < 13.5 and 10.8%, respectively. The accuracy ranged between 86.8 and 103.3%. Meanwhile, the average recovery was >70.7% and the matrix effect was within the range 109.5-113.7%. All of the obtained data confirmed the satisfactory sensitivity and selectivity of the developed method which was then successfully applied to evaluate the pharmacokinetic behavior of armepavine in mouse for the first time. The bioavailability of armepavine in mouse was calculated to be 11.3%. Copyright © 2018 John Wiley & Sons, Ltd.
Su, Chong; Sun, Hui; Yang, Hong; Yin, Lei; Zhang, Jiwen; Fawcett, John Paul; Gu, Jingkai
2017-11-01
Porcine relaxin is a 6 kDa peptide hormone of pregnancy with important physiological and pharmacological effects. It contains a number of analogs of which porcine relaxin B29 is one of the most important. To support the development of porcine relaxin B29 as a new drug, we established an UPLC-MS/MS method for its quantitation in dog plasma. Sample preparation by protein precipitation and ion exchange solid phase extraction was followed by UPLC on an XBridge™ BEH300 C18 column at 40 °C in a run time of only 5.5 min. Detection was performed on a Qtrap 6500 mass spectrometer using ESI in the positive ion mode with MRM of the transitions at m/z 831.7 [M+7H] 7+ → 505.4 and m/z 1162.4 [M+5H] 5+ → 226 for pRLX B29 and internal standard (recombinant human insulin), respectively. The method was linear over the concentration range 30-2000 ng/mL with no matrix effects. Intra- and inter-day precisions were < 15% with accuracies in the range 98.8-100.6%. The method was successfully applied to a pharmacokinetic study in beagle dogs after administration of a 0.15 mg/kg intravenous dose. Graphical abstract Sample preparation and detection procedure.
Xian, Yanping; Dong, Hao; Wu, Yuluan; Guo, Xindong; Hou, Xiangchang; Wang, Bin
2016-12-01
QuEChERS-based purification coupled with UPLC-MS/MS method, was developed for six quaternary ammonium compounds (QACs) determination in dairy products. Powder samples were firstly dispersed by water. Protein in liquid milk was precipitated and sample solution was extracted by acetonitrile. QuEChERS-based purification was used to purify the solution. QACs were finally separated by HILIC column and detected in MRM mode of MS/MS under ESI(+). The stable isotope benzyl-2,3,4,5,6-d5-dimethyltetradecylammonium bromide (C14-BAC-d5) was used as an internal standard. This method was validated in terms of linearity, sensitivity, precision, accuracy. Linear relations were favorable for QACs over the selected concentration ranges of 0.2-50μg/L, with correlation coefficients greater than 0.999. The limits of detection (LODs) were in the range of 0.4-14.5μg/kg. Recoveries were between 91.2% and 115% with RSDs of 2.8-7.5% for intra-day precision and 3.7-6.7% for inter-day precision. This validated method was successfully applied to determine the QACs concentrations in dairy products. Copyright © 2016 Elsevier Ltd. All rights reserved.
Determination of atmospheric organosulfates using HILIC chromatography with MS detection
NASA Astrophysics Data System (ADS)
Hettiyadura, A. P. S.; Stone, E. A.; Kundu, S.; Baker, Z.; Geddes, E.; Richards, K.; Humphry, T.
2015-06-01
Measurements of organosulfates in ambient aerosols provide insight to the extent of secondary organic aerosol (SOA) formation from mixtures of biogenic gases and anthropogenic pollutants. Organosulfates have, however, proved analytically challenging to quantify, due to lack of authentic standards and the complex sample matrix in which organosulfates are observed. This study presents a sensitive and accurate new analytical method for the quantification of organosulfates based upon ultra-performance liquid chromatography (UPLC) with negative electrospray ionization mass spectrometry (MS) with the aid of synthesized organosulfate standards. The separation is based upon hydrophilic interaction liquid chromatography (HILIC) with an amide stationary phase that provides excellent retention of carboxy-organosulfates and isoprene-derived organosulfates. The method is validated using six model compounds: methyl sulfate, ethyl sulfate, benzyl sulfate, hydroxyacetone sulfate, lactic acid sulfate and glycolic acid sulfate. A straightforward protocol for synthesis of highly pure organosulfate potassium salts for use as quantification standards is presented. This method is used to evaluate the efficiency and precision of two methods of ambient PM2.5 sample extraction. Spike recoveries averaged 98 ± 8% for extraction by ultra-sonication and 98 ± 10% for extraction by rotary shaking. Ultra-sonication was determined to be a better method due to its higher precision compared to rotary shaking. Analysis of ambient PM2.5 samples collected on 10-11 July 2013 in Centreville, AL, USA during the Southeast Atmosphere Study (SAS) confirms the presence of hydroxyacetone sulfate in ambient aerosol for the first time. Lactic acid sulfate was the most abundant compound measured (9.6-19 ng m-3), followed by glycolic acid sulfate (8-14 ng m-3) and hydroxyacetone sulfate (2.7-5.8 ng m-3). Trace amounts of methyl sulfate were detected, while ethyl sulfate and benzyl sulfate were not. Application of this HILIC separation method to ambient aerosol samples further demonstrates its utility in resolving additional biogenic organosulfates.
Zhong, Liping; Cheng, Fei; Lu, Xiaoyong; Duan, Yixiang; Wang, Xiaodong
2016-09-01
Breast cancer (BC) is not only the most frequently diagnosed cancer, but also the leading cause of cancer death among women worldwide. This study aimed to screen the potential salivary biomarkers for breast cancer diagnosis, staging, and biomarker discovery. For the first time, a UPLC-MS based method along with multivariate data analysis, was proposed for the global saliva metabonomics analysis and diagnosis of BC, which used both hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) separations and operated in both positive (ESI+) and negative (ESI-) ionization modes. On account of different polarities of endogenous metabolites, this method was established to overcome the boundedness of a single chromatographic approach. As a result, 18 potential metabolites for diagnosing BC were identified. A nonparametric Mann-Whitney U test, heat map, and the receiver operating characteristic (ROC) were exploited to analyze the data with the purpose of evaluating the predictive power of the 18 biomarkers. Significant differences (P<0.05) were disclosed in terms of the levels of the 18 potential biomarkers between BC patients and healthy controls (HC). Among the 18 biomarkers, three up-regulated metabolites, LysoPC (18:1), LysoPC (22:6) and MG (0:0/14:0/0:0) displayed the area under the curve (AUC) values of 0.920, 0.920 and 0.929, respectively, indicating the high accuracy of this method to predict BC. In this study, an integrated metabonomics analysis in human saliva for identifying potential biomarkers to diagnose and stage BC was successfully eastablished, which was non-invasive, reliable, low-cost, and simple. The HILIC was demonstrated to be essential for a comprehensive saliva metabonomics profiling as well as RPLC separation. This saliva metabonomics technique may provide new insight into the discovery and identification of diagnostic biomarkers for BC. Copyright © 2016. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Kumar, Nitin; Sangeetha, D.; Kalyanraman, L.
2017-11-01
For determination of process related impurities and degradation products of asenapine maleate in asenapine sublingual Tablets, a reversed phase, stability indicating UPLC method was developed. Acetonitrile, methanol and potassium dihydrogen phosphate buffer with tetra-n- butyl ammonium hydrogen sulphate as ion pair (pH 2.2; 0.01 M) at flow rate of 0.2 ml/min were used in gradient elution mode. Separation was achieved by using acquity BEH Shield RP18 column (1.7 μm, 2.1 mm×100 mm) at 35 ºC. UV detection was performed at 228 nm. Subsequently the liquid chromatography method was validated as per ICH. The drug product was exposed to the stress conditions of acid hydrolysis, base hydrolysis, water hydrolysis, oxidative, thermal, and photolytic. In oxidative stress and thermal stress significant degradation was observed. All the degradation products were well separated from analyte peak and its impurities. Stability indicating nature of the method was proved by demonstrating the peak purity of Asenapine peak in all the stressed samples. The mass balance was found >95% for all the stress conditions. Based on method validation, the method was found specific, linear, accurate, precise, rugged and robust.
Zheng, Yunliang; Chen, Yong; Ren, Yiping; Luan, Lianjun; Wu, Yongjiang
2012-01-25
An ultra-high pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the quantification of three major ingredients in Chinese lantern preparations (CLP) in rat plasma. Following extraction by ethyl acetate, the analytes were separated on an Acquity UPLC BEH Shield RP C(18) column using a gradient mobile phase system of acetonitrile-water. Electrospray ionization (ESI) tandem interface was employed prior to mass spectrometric detection. The calibration curves were linear over the range of 5.0-500.0 ng/ml for physalin D, 2.3-230.0 ng/ml for physalin G and 0.71-71.0 ng/ml for 4,7-didehydroneophysalin B. The average extraction recoveries, examined at four concentration levels, carried from 57.1% to 76.9%, and the accuracies ranged from 94.0% to 113.3% with precision (RSD) <15%. The validated method was successfully applied to the determination of the three physalins in rat plasma after intragastric administration of CLP suspension. Copyright © 2011 Elsevier B.V. All rights reserved.
Konieczna, Lucyna; Roszkowska, Anna; Niedźwiecki, Maciej; Bączek, Tomasz
2016-01-29
A simple and sensitive method using dispersive liquid-liquid microextraction (DLLME) followed by liquid chromatography coupled to mass spectrometry (LC-MS) with a hydrophilic interaction chromatography (HILIC) column was developed for the simultaneous determination of 13 compounds of different polarities, comprising monoamine neurotransmitters (dopamine, norepinephrine, epinephrine and serotonin) along with their respective precursors and metabolites, in human urine samples. The microextraction procedure was based on the fast injection of a mixture of ethanol (disperser solvent) and dichloromethane (extraction solvent) into a human urine sample, forming a cloudy solution in the Eppendorf tube. After centrifugation, the sedimented phase was collected and subsequently analyzed by LC-HILIC-MS in about 12min without a derivatization step. The separation was performed on an XBridge Amide™ BEH column 3.0×100mm, 3.5mm and the mobile phase consisted of phase A: 10mM ammonium formate buffer in water pH 3.0 and phase B: 10 mM ammonium formate buffer in acetonitrile, under gradient program elution. Tyrosine, tryptophan, 5-hydroxytryptophan, dopamine, epinephrine, norepinephrine, serotonin, 3-methoxytyramine, 5-hydroxyindole-3-acetic acid, 3,4-dihydroxy-l-phenylalanine and norvaline (internal standard) were detected in the positive ionization mode. While vanillylmandelic acid, homovanillic acid, 3,4-dihydroxyphenylacetic acid and 3,4-dihydroxybenzylamine (internal standard) were detected in the negative ionization mode. Parameters influencing DLLME and LC-HILIC-MS were investigated. Under the optimum conditions, the proposed method exhibited a low detection limit (5-10ngmL(-1)), and good linearity with R between 0.9991 and 0.9998. The recoveries in human urine samples were 99.0%±3.6%. for the 13 studied biogenic amines with intra- and inter-day RSDs of 0.24-9.55% and 0.31-10.0%, respectively. The developed DLLME-LC-MS method could be successfully applied for the determination of trace amounts of polar endogenous compounds, such as neurotransmitters, in human urine samples, including samples with a reduced volume obtained from pediatric patients. Copyright © 2015 Elsevier B.V. All rights reserved.
Man, Zhengyin; Wang, Quanlin; Li, Hesheng; Zhang, Aizhi
2014-12-01
A comprehensive analytical method based on ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry (UPLC-MS/MS) has been developed for the simultaneous determination of 33 primary aromatic amines (PAAs) in fine pigments such as gouache paint, oil painting pigment and acrylic paint. The primary aromatic amines in samples were extracted with acetonitrile. Then the extract was concentrated by centrifugation and nitrogen blow, finally diluted to 2 mL with methanol-water (1:9, v/v) and filtered through 0. 22 im membrane before UPLC-MS/MS analysis. The analytes were separated on a BEH Phenyl column (100 mm x 2. 1 mm, 1. 7 1µm) with 0. 07% (v/v) formic acid in methanol-water as mobile phases in gradient elution. The PAAs were detected by UPLC-MS/MS under multiple reaction monitoring (MRM) mode and quantified by the internal standard method. The separation conditions, fragment voltages and collision energies were optimized. The impacts of extraction times, extraction solvents and concentration methods on recoveries were studied. The limits of detection and limits of quantitation for the 33 primary aromatic amines were 5-50 µg/kg and 15-150 µg/kg respectively. The mean recoveries of three different dye products at three spiked levels were 70. 1% - 115. 8%. The relative standard deviations were 2. 1% - 15%. The expenmental results indicated that the method is simple, rapid, sensitive, accurate and can meet the requirements for the determination.
Wang, Zhi; Shi, Zongwei; Xi, Cunxian; Wang, Guomin; Cao, Shurui; Zhang, Lei; Tang, Bobin; Mu, Zhaode
2017-12-01
An analytical method was established for the rapid detection of antibiotic growth promoters (AGPs) in bovine muscle, and bovine blood and bovine urine, using ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). After the addition of an aqueous solution of EDTA-Na 2 , the pH of bovine urine samples was directly adjusted to 5.2 by acetic acid-ammonium acetate and purified by HLB solid-phase extraction cartridge; bovine muscle and bovine blood samples processing were extracted with acetonitrile (ACN) and ACNwater (90:10; v/v) without any purification step. The samples were then centrifuged, concentrated and analysed by UPLC-MS/MS on an ACQUITY UPLC® BEH C18 column using gradient elution. The developed method was validated and mean recovery percentages at three spiked levels were 74-119%, 76-115% and 76-119%, respectively, in bovine muscle, bovine blood, and bovine urine. The relative standard deviation (RSD) ranged from 1.0% to 14.7% in spiked bovine muscle, bovine blood and bovine urine. The limits of detection (LOD) of all analytes were in the ranges 0.11-3.82 µg kg -1 , 0.10-2.49 µg kg -1 and 0.06-4.53 µg kg -1 in bovine muscle, bovine blood, and bovine urine, respectively. The method was sensitive, accurate and was applied to monitor real samples. To the best of our knowledge, this is first method available for simultaneous determination of several classes of APGs in bovine muscle, and bovine blood and bovine urine.
2018-01-01
So-Cheong-Ryong-Tang, which is a standardized Korean medicine of the National Health Insurance, is a traditional prescription for the treatment of allergic rhinitis, bronchitis, and bronchial asthma. Simultaneous analysis and development of SCRT is essential for its stability, efficacy, and risk management. In this study, a simple, reliable, and accurate method using ultrahigh-performance liquid chromatography (UPLC) fingerprinting with a diode array detector (DAD) was developed for the simultaneous analysis. The chromatographic separation of the analytes was performed by an ACQUITY UPLC BEH C18 column (1.7 μM, 2.1 × 100 mm, Waters) with a mobile phase of water containing 0.01% (v/v) phosphoric acid and acetonitrile containing 0.01% (v/v) phosphoric acid. The flow rate and detection wavelength were set at 0.4 mL/min and 215, 230, 254, and 280 nm. All calibration curves of the thirteen components showed good linearity (R2 > 0.999). The limit of detection and limit of quantification ranged 0.001–0.360 and 0.004–1.200 µg/mL, respectively. The relative standard deviation (RSD) of intra- and interday was less than 2.60%, and the recoveries were within the range 76.08–103.79% with an RSD value of 0.03–1.50%. The results showed that the developed method was simple, reliable, accurate, sensitive, and precise for the quantification of bioactive components of SCRT. PMID:29854559
Yanamandra, R.; Vadla, C. S.; Puppala, U. M.; Patro, B.; Murthy, Y. L. N.; Parimi, A. R.
2012-01-01
A rapid, simple, sensitive and selective analytical method was developed by using reverse phase ultra performance liquid chromatographic technique for the simultaneous estimation of bambuterol hydrochloride and montelukast sodium in combined tablet dosage form. The developed method is superior in technology to conventional high performance liquid chromatography with respect to speed, resolution, solvent consumption, time, and cost of analysis. Elution time for the separation was 6 min and ultra violet detection was carried out at 210 nm. Efficient separation was achieved on BEH C18 sub-2-μm Acquity UPLC column using 0.025% (v/v) trifluoro acetic acid in water and acetonitrile as organic solvent in a linear gradient program. Resolutions between bambuterol hydrochloride and montelukast sodium were found to be more than 31. The active pharmaceutical ingredient was extracted from tablet dosage from using a mixture of methanol, acetonitrile and water as diluent. The calibration graphs were linear for bambuterol hydrochloride and montelukast sodium in the range of 6.25-37.5 μg/ml. The percentage recoveries for bambuterol hydrochloride and montelukast sodium were found to be in the range of 99.1-100.0% and 98.0-101.6%, respectively. The test solution was found to be stable for 7 days when stored in the refrigerator between 2-8°. Developed UPLC method was validated as per International Conference on Harmonization specifications for method validation. This method can be successfully employed for simultaneous estimation of bambuterol hydrochloride and montelukast sodium in bulk drugs and formulations. PMID:23325991
Jamalapuram, Seshulatha; Vuppala, Pradeep Kumar; Abdelazeem, Ahmed H; McCurdy, Christopher R; Avery, Bonnie A
2013-08-01
Methamphetamine abuse continues as a major problem in the USA owing to its powerful psychological addictive properties. AZ66, 3-[4-(4-cyclohexylpiperazine-1-yl)pentyl]-6-fluorobenzo[d]thiazole-2(3H)-one, an optimized sigma receptor ligand, is a promising therapeutic agent against methamphetamine. To study the in vivo pharmacokinetics of this novel sigma receptor ligand in rats, a sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed in rat plasma and validated. The developed method requires a small volume of plasma (100 μL) and a simple liquid-liquid extraction. The chromatographic separations were achieved in 3.3 min using an Acquity UPLC BEH Shield RP18 column. The mass spectrophotometric detection was carried out using a Waters Micromass Quattro MicroTM triple-quadrupole system. Multiple reaction monitoring was used for the quantitation with transitions m/z 406 → m/z 181 for AZ66 and m/z 448 → m/z 285 for aripiprazole. The method was validated over a concentration range of 1-3500 ng/mL and the lower limit of quantitation was determined to be 1 ng/mL. Validation of the assay demonstrated that the developed UPLC/MS/MS method was sensitive, accurate and selective for the determination of AZ66 in rat plasma. The present method has been successfully applied to an i.v. pharmacokinetic study in Sprague-Dawley rats. Copyright © 2013 John Wiley & Sons, Ltd.
Yin, Gang; Cheng, Xiaolan; Tao, Weiwei; Dong, Yu; Bian, Yong; Zang, Wenhua; Tang, Decai
2018-01-30
The herb-pair, Astragali Radix (AR) and Curcumae Rhizoma (CR), often occurs in traditional herbal prescriptions used for cancer treatment in Asian areas. In clinical application, the AR-CR herb pair was often produced by different preparation methods or with raw materials from different sources, which raised a challenge for quality control of the herb-pair medicines. In this paper, ultra high performance liquid chromatography coupled to triple quadrupole tandem mass spectrometry method (UPLC-QQQ-MS) was applied for the first time to simultaneously determine 17 main bioactive components for quality control of AR-CR herb pair. The chromatographic separation was studied on an ACQUITY UPLC BEH C 18 column (100mm×2.1mm, 1.7μm) with a mobile phase composed of 0.1% aqueous formic acid and acetonitrile using a gradient elution in 12min. The proposed method was optimized and validated by good linearity (r 2 >0.9970), limit of detection (0.33-10.78ng/mL), limit of quantification (0.81-2.54ng/mL), intra- and inter-day precisions (RSD≤3.64%, RSD≤5.68%), stability (RSD≤4.29%), repeatability (RSD≤5.98%), recovery (90.20-107.60%). The established method was successfully applied to comparative analysis of main bioactive components in AR-CR herb pair and its single herbs, and quality evaluation of different batches of clinical dispensing granules. Compared to the single herb, the content of most liposoluble constituents such as curcumenol, curdione, isocurcumenol, furanodienone, curcumol, and germacrone were remarkable increased in their herb pair, suggesting mixed preparation produced synergistic effects on promoting the extraction of bioactive ingredients. This study is the first time to report the rapid and simultaneous analysis of 17 compounds in AR-CR herb pair by UPLC-QQQ-MS, and provides a feasible method for holistic quality control of preparations containing AR-CR herb-pair. Copyright © 2017 Elsevier B.V. All rights reserved.
Liu, Haiyan; Xu, Hongjiang; Song, Wei; Zhang, Yinsheng; Yu, Sen; Huang, Xin
2016-03-15
Rapid, sensitive, selective and accurate ultra performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantification of elbasvir (ELB) in rat plasma with deuterated elbasvir (ELB-D6) as internal standard (IS).Sample preparation was done by protein precipitation using acetonitrile containing 50 ng/mL IS. Chromatographic separation was achieved by an UPLC BEH C18 column (2.1 mm × 50 mm, 1.7 μm) column with a gradient mobile phase consisting of acetonitrile-water (containing 5.0mM ammonium acetate with 0.01% acetic acid, pH 4.5) as mobile phase at a flow rate of 0.3 mL/min for 3 min. ELB was monitored using positive electrospray triple quadrupole mass spectrometer (Waters Xevo TQ-S) via multiple reaction monitoring (MRM) mode. The monitored transitions were set at m/z 882.51→656.42 and m/z 888.49→662.43 for ELB and ELB-D6, respectively. The achieved lower limit of quantification was 1.0 ng/mL. The validated method had an excellent linearity in the range of 1.0-2000 ng/mL (r(2)>0.996). Recovery efficiency at three levels QC concentrations of 2.0 (low), 160 (medium) and 1600 (high) ng/mLwas in the range of 98.29-106.40% for ELB. Matrix effect was found to be minimal. The intra- and inter-day precisions were less than 7.01%. The intra- and inter-day accuracies were determined to be within ±6.23% for all accuracy measurements. The validated simple and rapid UPLC-MS/MS method was successfully used to the pharmacokinetics study of ELB in rats, providing its applicability in relevant preclinical studies. Copyright © 2016 Elsevier B.V. All rights reserved.
Noetzli, Muriel; Ansermot, Nicolas; Dobrinas, Maria; Eap, Chin B
2012-05-01
A previously developed high performance liquid chromatography mass spectrometry (HPLC-MS) procedure for the simultaneous determination of antidementia drugs, including donepezil, galantamine, memantine, rivastigmine and its metabolite NAP 226-90, was transferred to an ultra performance liquid chromatography system coupled to a tandem mass spectrometer (UPLC-MS/MS). The drugs and their internal standards ([(2)H(7)]-donepezil, [(13)C,(2)H(3)]-galantamine, [(13)C(2),(2)H(6)]-memantine, [(2)H(6)]-rivastigmine) were extracted from 250 μL human plasma by protein precipitation with acetonitrile. Chromatographic separation was achieved on a reverse phase column (BEH C18 2.1 mm × 50 mm; 1.7 μm) with a gradient elution of an ammonium acetate buffer at pH 9.3 and acetonitrile at a flow rate of 0.4 mL/min and an overall run time of 4.5 min. The analytes were detected on a tandem quadrupole mass spectrometer operated in positive electrospray ionization mode, and quantification was performed using multiple reaction monitoring. The method was validated according to the recommendations of international guidelines over a calibration range of 1-300 ng/mL for donepezil, galantamine and memantine, and 0.2-50 ng/mL for rivastimgine and NAP 226-90. The trueness (86-108%), repeatability (0.8-8.3%), intermediate precision (2.3-10.9%) and selectivity of the method were found to be satisfactory. Matrix effects variability was inferior to 15% for the analytes and inferior to 5% after correction by internal standards. A method comparison was performed with patients' samples showing similar results between the HPLC-MS and UPLC-MS/MS procedures. Thus, this validated UPLC-MS/MS method allows to reduce the required amount of plasma, to use a simplified sample preparation, and to obtain a higher sensitivity and specificity with a much shortened run-time. Copyright © 2012 Elsevier B.V. All rights reserved.
Wang, Ting; Hu, Xiao-Chun; Cai, Zhi-Peng; Voglmeir, Josef; Liu, Li
2017-09-06
Recent progress in the relationship between carbohydrate cross-reactive determinants (CCDs) and allergic response highlights the importance of carbohydrate moieties in the innate immune system. Previous research pointed out that the protein allergen in Ginkgo biloba seeds is glycosylated, and the oligosaccharides conjugated to these proteins might also contribute to the allergy. The aim of this study was to analyze carbohydrate moieties, especially N-linked glycans, of glycoproteins from Ginkgo seeds originating from different places for detailed structures, to enable further research on the role played by N-glycans in Ginkgo-caused allergy. Results of monosaccharide composition and immunoblotting assays indicated the existence of N-glycans. Detailed structural elucidation of the N-glycans was further carried out by means of hydrophilic interaction ultraperformance liquid chromatography (HILIC-UPLC) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In total, 14 out of 16 structures detected by UPLC were confirmed by MALDI-TOF-MS and tandem mass spectrometry, among which complex-type N-glycans bearing Lewis A determinants and high-mannose-type N-glycans were identified from Ginkgo seeds for the first time. Precise quantification of N-glycans was performed by use of an external standard, and both the absolute amount of each N-glycan and the percentage of different types of N-glycan showed significant diversity among the samples without any pattern of geographic variation.
Determination of higenamine in dietary supplements by UHPLC/MS/MS method.
Stajić, A; Anđelković, M; Dikić, N; Rašić, J; Vukašinović-Vesić, M; Ivanović, D; Jančić-Stojanović, B
2017-11-30
From 1st January 2017 higenamine was added on the WADA (World Anti-doping Agency) Prohibited list under S3 group beta-2 agonists as at all times banned substance for the athletes. The main origine of higenamine (or norcoclaurine) are different plants including Nandina domestica, Aconitum carmichaelii, Asarum heterotropioides, Galium divaricatum, Annona squamosa, Nelumbo nucifera etc. Higenamine main use is related to weight loss and it could be found (un)labeled in different dietary supplements. The objective of this study was development of sensitive and reliable UHPLC/MS/MS method for determination of higenamine in various dietary supplement samples. In order to obtain high method sensitivity, hydrophilic interaction liquid chromatography (HILIC) mode was applied. Separation was carried out on UHPLC Acquity BEH HILIC analytical column (2.1mm×100mm, 1.7μm particle size). Mobile phase consisted of 0.1% formic acid in water and acetonitrile, respectively, was mixed in ratio of 30:70, v/v. Flow rate was set at 0.2mLmin -1 . Quercetin was used as an internal standard. ESI (+) source ionization mode using multi reaction monitoring (MRM) mode was utilized and three ion transitions of higenamine were followed 272.08→107.01, 272.08→161.07 and 272.08→77.08. Developed method was fully validated and applied for identification and quantification of higenamine in different dietary supplements. According to the results, the most of investigated supplements were free of higenamine, and on the other hand, presence of higenamine was confirmed in some samples while it was not declared on the label. Copyright © 2017 Elsevier B.V. All rights reserved.
Xu, Pan; Du, Shou-Ying; Lu, Yang; Bai, Jie; Liu, Hui-Min; Du, Qiu; Chen, Zhen-Zhen; Wang, Zhen
2014-06-01
To establish a UPLC-MS/MS method for the simultaneous determination of geniposide, genipin 1-O-beta-D-gentiobioside and geniposidic acid in rat brains and study the brain pharmacokinetics of the three iridoid glycosides in stroke rat after the oral administration of Xingnaojing. In this experiment, brain samples were precipitated with protein for twice. Acquity BEH C18 column was adopted, with acetonitrile-0.1% formic acid-water as the mobile phase for gradient elution. ESI source was adopted for mass spectra; multiple reaction monitoring (MRM) was conducted to detect negative ions. The time for sample analysis was 3.5 min. the results showed good linear relations among the three iridoid glycosides, with the extraction recovery between 99.6% and 114.3%, good intra- and inter-day precisions and accuracies and stability in line with the requirements. The t1/2 and MRT in the three components were similar in brains of stroke rats. Geniposide and genipin 1-O-beta-D-gentiobioside showed double peaks; where as geniposidic acid showed a single peak. In conclusion, the method is so specific, sensitive, accurate and reliable that it can be used to study the brain pharmacokinetics of Xingnaojing oral preparation.
Wang, Yanjuan; Wen, Jing; Zheng, Weihua; Zhao, Longshan; Fu, Xiaohuan; Wang, Zhenzhong; Xiong, Zhili; Li, Famei; Xiao, Wei
2015-01-01
A simple, specific and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was established and validated for simultaneous determination of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid and geniposide in rat plasma using puerarin as an internal standard (IS). Plasma samples were pretreated by a one-step direct protein precipitation procedure with acetonitrile after acidified using as little as 50 μL plasma. Chromatographic separation was performed on an Acquity BEH C18 column (100 × 2.1 mm, 1.7 µm) at a flow rate of 0.2 mL/min by a gradient elution, using 0.2% acetic acid-methanol as mobile phase. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via electrospray ionization source with negative ion mode. Calibration curves showed good linearity (r > 0.995) over wide concentration ranges. The intra- and inter-day precisions were <15%, and the accuracy was within ±8.0%. The validated method was successfully applied to a pharmacokinetic study of the four bioactive components in rats after intravenous administration of Reduning injection. Copyright © 2014 John Wiley & Sons, Ltd.
Krishnaiah, Ch; Reddy, A Raghupathi; Kumar, Ramesh; Mukkanti, K
2010-11-02
A simple, precise, accurate stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the quantitative determination of purity of Valsartan drug substance and drug products in bulk samples and pharmaceutical dosage forms in the presence of its impurities and degradation products. The method was developed using Waters Aquity BEH C18 (100 mm x 2.1 mm, 1.7 microm) column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 225 nm, the run time was within 9.5 min, which Valsartan and its seven impurities were well separated. Valsartan was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Valsartan was found to degrade significantly in acid and oxidative stress conditions and stable in base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per international conference on harmonization (ICH) guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of Valsartan in pharmaceutical dosage forms.
Garbis, Spiros D; Roumeliotis, Theodoros I; Tyritzis, Stavros I; Zorpas, Kostas M; Pavlakis, Kitty; Constantinides, Constantinos A
2011-02-01
The current proof-of-principle study was aimed toward development of a novel multidimensional protein identification technology (MudPIT) approach for the in-depth proteome analysis of human serum derived from patients with benign prostate hyperplasia (BPH) using rational chromatographic design principles. This study constituted an extension of our published work relating to the identification and relative quantification of potential clinical biomarkers in BPH and prostate cancer (PCa) tissue specimens. The proposed MudPIT approach encompassed the use of three distinct yet complementary liquid chromatographic chemistries. High-pressure size-exclusion chromatography (SEC) was used for the prefractionation of serum proteins followed by their dialysis exchange and solution phase trypsin proteolysis. The tryptic peptides were then subjected to offline zwitterion-ion hydrophilic interaction chromatography (ZIC-HILIC) fractionation followed by their online analysis with reversed-phase nano-ultraperformance chromatography (RP-nUPLC) hyphenated to nanoelectrospray ionization-tandem mass spectrometry using an ion trap mass analyzer. For the spectral processing, the sequential use of the SpectrumMill, Scaffold, and InsPecT software tools was applied for the tryptic peptide product ion MS(2) spectral processing, false discovery rate (FDR) assessment, validation, and protein identification. This milestone serum analysis study allowed the confident identification of over 1955 proteins (p ≤ 0.05; FDR ≤ 5%) with a broad spectrum of biological and physicochemical properties including secreted, tissue-specific proteins spanning approximately 12 orders of magnitude as they occur in their native abundance levels in the serum matrix. Also encompassed in this proteome was the confident identification of 375 phosphoproteins (p ≤ 0.05; FDR ≤ 5%) with potential importance to cancer biology. To demonstrate the performance characteristics of this novel MudPIT approach, a comparison was made with the proteomes resulting from the immunodepletion of the high abundant albumin and IgG proteins with offline first dimensional tryptic peptide separation with both ZIC-HILIC and strong cation exchange (SCX) chromatography and their subsequent online RP-nUPLC-nESI-MS(2) analysis.
Krishnaiah, Ch; Vishnu Murthy, M; Kumar, Ramesh; Mukkanti, K
2011-03-25
A simple, sensitive and reproducible ultra performance liquid chromatography (UPLC) coupled with a photodiode array detector method was developed for the quantitative determination of olanzapine (OLN) in API and pharmaceutical dosage forms. The method is applicable to the quantification of related substances and assays of drug substances. Chromatographic separation was achieved on Acquity UPLC BEH 100-mm, 2.1-mm, and 1.7-μm C-18 columns, and the gradient eluted within a short runtime, i.e., within 10.0 min. The eluted compounds were monitored at 250 nm, the flow rate was 0.3 mL/min, and the column oven temperature was maintained at 27°C. The resolution of OLN and eight (potential, bi-products and degradation) impurities was greater than 2.0 for all pairs of components. The high correlation coefficient (r(2)>0.9991) values indicated clear correlations between the investigated compound concentrations and their peak areas within the test ranges. The repeatability and intermediate precision, expressed by the RSD, were less than 2.4%. The accuracy and validity of the method were further ascertained by performing recovery studies via a spike method. The accuracy of the method expressed as relative error was satisfactory. No interference was observed from concomitant substances normally added to the tablets. The drug was subjected to the International Conference on Harmonization (ICH)-prescribed hydrolytic, oxidative, photolytic and thermal stress conditions. The performance of the method was validated according to the present ICH guidelines for specificity, limit of detection, limit of quantification, linearity, accuracy, precision, ruggedness and robustness. Copyright © 2010 Elsevier B.V. All rights reserved.
Li, Guofei; Cai, Cuifang; Ren, Tianyang; Tang, Xing
2014-01-01
With the purpose to carry out the pharmacokinetic studies of 10-hydroxy camptothecin (10-HCPT) and hydroxyethyl starch (10-HCPT-HES) conjugate, an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated. The analytes, 10-HCPT and the internal standard, Diphenhydramine hydrochloride were extracted with ethyl acetate-isopropanol (95:5, v/v) and separated on an ACQUITY UPLC™ BEH C18 column using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) with a linear gradient program. With positive ion electrospray ionization (ESI), the analytes were monitored on a triple quadrupole mass spectrometer in the multiple reaction monitoring (MRM) mode. Linear calibration curves were obtained over the concentration ranges of 0.5-2500ng/mL. The intra- and inter-day precisions were less than 9.8% and 10.8%, respectively. The accuracy was within 12.1%. The mean recoveries of 10-HCPT at three concentrations of 2.5, 100, 2000ng/mL were higher than 87.2%. Commercial 10-HCPT injection and 10-HCPT-HES conjugate were administered intravenously at an equal dose of 10-HCPT at 0.5mg/kg. The biological half-life of conjugate was increased significantly from 10min to 3.15h and the bioavailability was 40 times higher than 10-HCPT injection. Consequently, the proposed UPLC-ESI-MS/MS method was proved to be sensitive, specific and reliable to analyze 10-HCPT in biological samples; 10-HCPT and HES conjugate is a promising strategy for delivery of 10-HCPT with prolonged half time and improved bioavailability. Copyright © 2013 Elsevier B.V. All rights reserved.
Zhang, Aizhi; Wang, Quanlin; Cao, Lili; Li, Yu; Shen, Hao; Shen, Jian; Zhang, Shufen; Man, Zhengyin
2016-02-01
A multiresidue analytical method for the determination of 250 pesticide residues in vegetables was developed by using QuEChERS-ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The target compounds were extracted with acetonitrile containing 1% (v/v) acetic acid, purified by a mixed sorbent of MgSO4, primary secondary amine (PSA), graphitized carbon black (GCB) and C18, separated on a Waters ACQUITY™ UPLC BEH C18 column (100 mm x 2. 1 mm, 1.7 µm) and detected by UPLC-MS/MS. Anhydrous magnesium sulfate was used as a dewatering agent. The effects of the amounts of MgSO4, PSA, GCB and C18 added on the recoveries of 250 pesticides were investigated. The results showed that the purification effect was best when 300 mg MgSO4, 200 mg PSA, 10 mg GCB and 100 mg C18 in 2 mL of the extract were added. For the 250 pesticide residues, the limits of detection (LODs) of the method were from 0. 01 to 50. 00 g/kg. The recoveries obtained ranged from 60. 1% to 120% at three spiked levels in Chinese chives with the relative standard deviations between 3. 5% and 19. 5% using matrix matched external standard method. The results showed that the method is able to meet requirements of the multiresidue detection of the 250 pesticides in vegetable. The method has the advantages of rapidity, simplicity, high sensitivity and better purification effect. It is suitable for the rapid determination of the common pesticides in vegetables, and it provides a strong guarantee for the risk assessments of the quality and safety of vegetables.
Zheng, Yunliang; Chen, Yong; Ren, Yiping; Luan, Lianjun; Wu, Yongjiang
2012-01-01
Chinese lantern is the calyx or calyx-with-fruit of the plant Physalis alkekengi .var. franchetii (Solanaceae), and is potential material for the food and pharmaceutical industries. Physalins are the most active and representative secondary metabolites of Chinese lantern. A separation and quantification method based on UPLC-ESI-MS/MS was developed for the quantitative analysis of five active physalins. The transformation products were also detected and identified for the first time. To establish a LC-MS/MS method to quantify five physalins in Chinese lantern for the purpose of quality control, and to identify the transformation products of 4,7-didehydrophysalin B. The separation was carried out on an Acquity UPLC BEH Shield RP C₁₈-column with water and acetonitrile as the mobile phase under gradient conditions. ESI-MS/MS was used as the detector to quantify the five physalins. The transformation products of 4,7-didehydroneophysalin B were detected by UPLC-PDA-ESI-MS/MS and identified through comparing their HRMS and MS² ion fragmentations with corresponding references. All the compounds showed good linearity (R² > 0.998). The recoveries, measured at three concentration levels, varied from 98.8 to 101.4% with RSDs < 4.5%. The total contents of the five physalins in Chinese lantern varied significantly. Three transformation products of 4,7-didehydroneophysalin B were detected and tentatively identified. The present study developed a highly effective analytical method for the quality control of Chinese lantern, and it could provide comprehensive information for quality evaluation and new drug development of Chinese lantern. Copyright © 2011 John Wiley & Sons, Ltd.
Man, Zhengyin; Wang, Quanlin; Li, Hesheng; Zhang, Aizhi; Shen, Jian
2015-03-01
A comprehensive analytical method based on ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry (UPLC-MS/MS) has been developed for the simultaneous determination of 33 primary aromatic amines (PAAs) in polystyrene (PS) and polyethylene (PE) masterbatches for foods. The PS masterbatches were dissolved with dichloromethane, and methanol was added to precipitate after extraction by ultrasound extraction. Then the extract was purified by passing through a carbon graphite solid phase extraction column. The PE masterbatches were swelled and extracted with dichloromethane by ultrasound. The purified PS solution and PE extract were concentrated, and diluted to 2 mL with methanol-water (1:9, v/v), and filtered through the membranes of 0.22 µm before UPLC-MS/MS analysis. The analytes were separated on a BEH Phenyl column (100 mm x 2.1 mm, 1.7 µm), eluted by gradient with 0.07% (v/v) formic acid in methanol-water (1:9, v/v). The PAAs were detected by UPLC-MS/MS under multiple reaction monitoring (MRM) mode and quantified by the internal standard method. The separation conditions, fragment voltages and collision energies were optimized. The impacts of extraction times, extraction solvents and concentration methods on recoveries were studied. The limits of detection for the 33 primary aromatic amines were 6-10 µg/kg, and the limits of quantitation were 20-30 µg/kg. The mean recoveries of the two different masterbatch products at three spiked levels of 20, 100, 200 µg/kg were 61.3%-119.8%, and the relative standard deviations were 1.4%-14.8%. The experimental results indicated that the method is simple, rapid, sensitive, accurate, and can meet the related requirements for determination.
[Quality control of Guci tablets using UPLC-ELSD fingerprint analysis coupled with chemometrics].
Wang, Ya-Dan; Dai, Zhong; Sun, Cai-Lin; Wu, Xian-Fu; Ma, Shuang-Cheng
2018-03-01
Ultra-performance liquid chromatography-evaporative light scattering detection (UPLC-ELSD) fingerprint analysis method was established for quality control of Guci tablets. Chromatographic separation was performed on Waters Acquity UPLC BEH C₁₈ column (2.1 mm×100 mm, 1.7 μm) at 30 °C of column temperature. Acetonitrile-0.1% formic acid solution was adopted as mobile phase for gradient elution. The flow rate was set at 0.3 mL·min⁻¹, and the injection volume was 3 μL. Detection was carried out on an ELSD with a nitrogen pressure of 0.28 MPa, drift tube temperature of 60 °C, and gain of 400. A total of 39 batches of samples produced by six manufacturers were measured by using the above method and the data were analyzed by ChemPattern software. The peak present in more than 75% of the samples was defined as a common peak, and 30 common peaks were determined. Among them, 19 peaks were identified by rapid resolution liquid chromatography/tandem mass spectrometry (RRLC-MS/MS) method, 16 of which were confirmed by reference substances. The similarity of the tested samples was 0.47-0.98, suggesting that the quality of the samples from different manufacturers varied greatly. Furthermore, principal component analysis (PCA) and hierarchical analysis (HCA) were performed to clarify the main different components in samples. The results indicated that there might be some feeding problems about Paeoniae Radix Alba, Notoginseng Radix et Rhizoma, and Clematidis Radix et Rhizoma in a few manufacturers. This study provided some evidences for the overall quality control of Guci tablets, as well as its quality standard improvements. Copyright© by the Chinese Pharmaceutical Association.
Wang, Jiang; Pavurala, Naresh; Xu, Xiaoming; Krishnaiah, Yellela S R; Faustino, Patrick J
2018-05-04
To evaluate the bioavailability and pharmacokinetic profiles of two novel galantamine formulations as medical countermeasure products, an ultra-performance liquid chromatography-single quadrupole mass spectrometry (UPLC-MS) method was developed and validated for quantifying galantamine in guinea pig plasma using solid-phase extraction with a mixed mode strong cation exchange reversed-phase cartridge. Chromatographic separation was achieved on a Waters Acquity UPLC BEH C 18 column maintained at 40°C. The mobile phases were solution A, acetonitrile-water, 5:95 (v/v) and solution B, acetonitrile-water 90:10 (v/v), both containing 2 mM ammonium formate and 0.2% formic acid. The mobile phase was delivered utilizing a 3 min gradient program start with 95%A-5%B at a flow rate of 0.6 mL/min. The analyte and internal standard, galantamine-d3, were detected by selected ion monitoring mode on a Waters 3100 single quadrupole mass spectrometer with positive electrospray ionization. The method was validated according to the US Food and Drug Administration bioanalytical guidance. The method was selective and was linear over the analytical range of 2-2000 ng/mL. Accuracy and precision were acceptable with intra- and inter-day accuracies between 96.8 and 101% and precisions (RSD) <4.88%. The method was successfully implemented to measure galantamine plasma levels in a series of pre-clinical bioavailability studies for the evaluation of novel galantamine formulations. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Zhang, Qiao; Zhang, Kai-Cheng; Lou, Jian-Wei; Guo, Shu-Chen; Zhang, Yi; Yao, Wei-Feng; Tang, Yu-Ping; Wu, Jian-Hua; Zhang, Li
2018-06-05
The dried roots of Euphorbia kansui T.N. Liou ex T.P. Wang have been traditionally used for edema in China. However, the severe toxicity caused by Euphorbia kansui has seriously restricted its clinical application. Therefore, in order to study the material basis of the toxicity attenuation effect of processing with vinegar, a rapid, sensitive, validated and reliable UPLC-MS/MS method was developed to determine twelve compounds in ethyl acetate extracts of Euphorbia kansui before and after fry-baked with vinegar simultaneously. Meanwhile, the study of their toxic effect on zebrafish was conducted. Chromatographic separation was accomplished on Waters BEH C 18 UPLC column. 0.3% formic acid in water and acetonitrile were used as mobile phase with a flow rate of 0.40 mL/min and a temperature at 30 °C. The analysis was performed in multiple reaction monitoring (MRM) mode using positive electrospray ionization (ESI). Furthermore, the toxic research results indicated that the toxicity of Euphorbia kansui was decreased after vinegar-processed, which might because of the increase in the content of 5-O-benzoyl-20-deoxyingenol and the decrease in the contents of the remaining terpenoids in ethyl acetate extracts of Euphorbia kansui fry-baked with vinegar. This study demonstrated that the method used is a powerful approach to determine the content of twelve compounds that responsible for the toxic effect of Euphorbia kansui at the same instant. And provided the experimental evidence for the rationale behind the reduction of toxicity. Copyright © 2018 Elsevier B.V. All rights reserved.
Stragierowicz, Joanna; Daragó, Adam; Brzeźnicki, Sławomir; Kilanowicz, Anna
2017-07-26
Glutamate (Glu) and γ-aminobutyric acid (GABA) are the main neurotransmitters in the central nervous system for excitatory and inhibitory processes, respectively. Monitoring these neurotransmitters is an essential tool in establishing pathological functions, among others in terms of occupational exposure to toxic substances. We present modification of the HPLC (high-performance liquid chromatography) to the UPLC (ultra-performance liquid chromatography) method for the simultaneous determination of glutamate and γ-aminobutyric acid in a single injection. The isocratic separation of these neurotransmitter derivatives was performed on Waters Acquity BEH (ethylene bridged hybrid) C18 column with particle size of 1.7 μm at 35°C using a mobile phase consisting of 0.1 M acetate buffer (pH 6.0) and methanol (60:40, v/v) at a flow rate of 0.3 ml/min. The analytes were detected with the fluorescence detector (FLD) using derivatization with o-phthaldialdehyde (OPA), resulting in excitation at 340 nm and emission at 455 nm. Several validation parameters including linearity (0.999), accuracy (101.1%), intra-day precision (1.52-1.84%), inter-day precision (2.47-3.12%), limit of detection (5-30 ng/ml) and quantification (100 ng/ml) were examined. The developed method was also used for the determination of these neurotransmitters in homogenates of selected rat brain structures. The presented UPLC-FLD is characterized by shorter separation time (3.5 min), which is an adaptation of the similar HPLC methods and is an alternative for more expensive references techniques such as liquid chromatography coupled with tandem mass-spectrometry (LC-MS/MS) methods. Med Pr 2017;68(5):583-591. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Determination of 25-OCH3-PPD and the related substances by UPLC-MS/MS and their cytotoxic activity.
Ding, Meng; Lu, Jingjing; Zhao, Chen; Zhang, Sainan; Zhao, Yuqing
2016-06-01
20(R)-25-methoxyl-dammarane-3β,12β,20-triol (25-OCH3-PPD) is a promising antitumor compound belonging to triterpenoid saponins isolated from radix notoginseng. A systematic research on the related impurities in raw material of 25-OCH3-PPD has not been conducted. In this study, three impurities obtained by HPLC-ELSD and characterized by (13)C NMR and MS were observed in the raw material of 25-OCH3-PPD. Cytotoxic activities of the related substances were also evaluated, of which impurity B with 25-OCH3-PPD showed synergistic inhibitory activity against BGC-823 with IC50 values of 8.33μM. Furthermore, a rapid and selective UPLC-MS/MS method was developed for simultaneous determination of the principal component and three related substances in the raw material of 25-OCH3-PPD. Multiple reaction monitoring scan mode was used for the quantification of 20(R)-25-OCH3-PPD and its three related substances. The four constituents were separated within 11min on a BEH C18 column (100 mm×2.1mm, 1.7μm) using a mobile phase comprising methanol and 0.03% formic acid water (82:18, v/v) at a flow rate of 0.2mL/min. The proposed UPLC-MS/MS method displayed acceptable levels of linearity, precision, repeatability, and accuracy. In addition, the proposed method was successfully applied for the establishment of a rational quality control standard for the raw material of 25-OCH3-PPD. Copyright © 2016 Elsevier B.V. All rights reserved.
Chen, Wei-Ying; Zhou, Xian-Zhen; Wu, Li-Lan; Wu, Yun-Shan; Wang, Shu-Mei; Liu, Bo; Guo, De-An
2017-07-01
Caesalpinia sappan L. is a traditional medicinal plant which is used for promoting blood circulation and cerebral apoplexy therapy in China. Previous reports showed that the extracts of Caesalpinia sappan L. could exert vasorelaxant activity and anti-inflammation activity. Protosappanin B is a major constituent of C. sappan L., and showed several important bioactivities. The separation was achieved by an Acquity UPLC BEH Symmetry Shield RP 18 column (1.7 μm, 2.1 × 100 mm) column with the gradient mobile phase consisting of 5 mm ammonium acetate aqueous solution and acetonitrile. Detection was carried out by using negative-ion electrospray tandem mass spectrometry via multiple reaction monitoring. Plasma samples were preprocessed by an extraction with ethyl acetate, and apigenin was used as internal standard. The current UPLC-MS/MS assay was validated for linearity, accuracy, intraday and interday precisions, stability, matrix effects and extraction recovery. After oral and intravenous administration, the main pharmacokinetic parameters were as follows: peak concentrations, 83.5 ± 46.2 and 1329.6 ± 343.6 ng/mL; areas under the concentration-time curve, 161.9 ± 69.7 and 264.9 ± 56.3 μg h/L; and half-lives, 3.4 ± 0.9 and 0.3 ± 0.1 h, respectively. The absolute bioavailability in rats of protosappanin B was 12.2%. The method has been successfully applied to a pharmacokinetic and bioavailability study of protosappanin B in rats. Copyright © 2016 John Wiley & Sons, Ltd.
Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masae; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Seno, Hiroshi
2011-06-01
In this report, a high-throughput and sensitive method for analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) in the positive and negative ionization modes using tolbutamide as internal standard is presented. After pretreatment of a plasma sample by solid-phase extraction with an Oasis HLB cartridge, muscle relaxants were analyzed by UPLC with Acquity UPLC BEH C(18) column and Acquity TQD tandem quadrupole mass spectrometer equipped with an electrospray ionization interface. The calibration curves for muscle relaxants spiked into human plasma equally showed good linearities in the nanogram per milliliter order range. The detection limits (signal-to-noise ratio = 3) was as low as 0.1-2 ng/mL. The method gave satisfactory recovery rates, accuracy, and precision for quality control samples spiked with muscle relaxants. To further validate the present method, 250 mg of chlorphenesin carbamate was orally administered to a healthy male volunteer, and the concentrations of chlorphenesin carbamate in plasma were measured 0.5, 1, 2, 4, 6, and 8 h after dosing; their concentrations in human plasma were between 0.62 and 2.44 μg/mL. To our knowledge, this is the first report describing simultaneous analysis of over more than two central-acting muscle relaxants by liquid chromatography-tandem mass spectrometry. This has been realized by the capability of our instrument for simultaneous multiple reaction monitoring of the target compounds in both positive and negative ionization modes. Therefore, the present method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.
NASA Astrophysics Data System (ADS)
Wabaidur, Saikh Mohammad; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan
2013-05-01
In present study, a rapid and sensitive method using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet. The optimum chromatographic separation was carried out on a reversed phase Waters® Acquity UPLC BEH C18 column (1.7 μm particle size, 100 mm × 2.1 mm ID) with an isocratic elution profile and mobile phase consisting of 0.1% formic acid in water and acetonitrile (75:25, v/v, pH 3.5) at flow rate of 0.5 mL min-1. The influences of mobile phase composition, flow rate and pH on chromatographic resolution were investigated. The total chromatographic analysis time was as short as 2 min with excellent resolution. Detection and quantification of the target compounds were carried out with a triple quadrupole mass spectrometer using negative electrospray ionization (ESI) and multiple reaction monitoring (MRM) modes. The performance of the method was evaluated and very low limits of detection less than 0.09 μg g-1, excellent coefficient correlation (r2 > 0.999) with liner range over a concentration range of 0.1-1.0 μg g-1 for both L-ascorbic acid and acetylsalicylic acid, and good intraday and interday precisions (relative standard deviations (R.S.D.) <3%), were obtained. Comparison of system performance with traditional liquid chromatography-photo diode array detector (HPLC-PDA) was made with respect to analysis time, sensitivity, linearity and precisions. The proposed UPLC-MS/MS method was found to be reproducible and appropriate for quantitative analysis of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet.
Boundy, Michael J; Selwood, Andrew I; Harwood, D Tim; McNabb, Paul S; Turner, Andrew D
2015-03-27
Routine regulatory monitoring of paralytic shellfish toxins (PST) commonly employs oxidative derivitisation and complex liquid chromatography fluorescence detection methods (LC-FL). The pre-column oxidation LC-FL method is currently implemented in New Zealand and the United Kingdom. When using this method positive samples are fractionated and two different oxidations are required to confirm the identity and quantity of each PST analogue present. There is a need for alternative methods that are simpler, provide faster turnaround times and have improved detection limits. Hydrophilic interaction liquid chromatography (HILIC) HPLC-MS/MS analysis of PST has been used for research purposes, but high detection limits and substantial sample matrix issues have prevented it from becoming a viable alternative for routine monitoring purposes. We have developed a HILIC UPLC-MS/MS method for paralytic shellfish toxins with an optimised desalting clean-up procedure on inexpensive carbon solid phase extraction cartridges for reduction of matrix interferences. This represents a major technical breakthrough and allows sensitive, selective and rapid analysis of paralytic shellfish toxins from a variety of sample types, including many commercially produced bivalve molluscan shellfish species. Additionally, this analytical approach avoids the need for complex calculations to determine sample toxicity, as unlike other methods each PST analogue is able to be quantified as a single resolved peak. This article presents the method development and optimisation information. A thorough single laboratory validation study has subsequently been performed and this data will be presented elsewhere. Copyright © 2015 Elsevier B.V. All rights reserved.
Tylová, Tereza; Kolařík, Miroslav; Olšovská, Jana
2011-07-01
A new simple ultra-high-performance liquid chromatography method with diode array detection (UHPLC-DAD) was developed for chemical fingerprinting analysis of extracellular metabolites in fermentation broth of Geosmithia spp. The SPE method employing Oasis MCX strong cation-exchange mixed-mode polymeric sorbent was chosen for extraction of the metabolites. The analyses were performed on an Acquity UPLC BEH C18 column (100 × 2.1 mm i.d.; particle size, 1.7 μm; Waters) using a gradient elution program with an aqueous solution of trifluoroacetic acid and acetonitrile as the mobile phase. The applicability of the method was proved by analysis of 38 strains produced by different species and isolated from different sources (hosts). The results revealed the correlation of obtained UHPLC-DAD fingerprints with taxonomical identity.
Li, Zhe; Xing, Yuping; Guo, Xingjie; Cui, Yan
2017-07-15
There are significant differences in d-amino acid concentrations between healthy people and Alzheimer's disease patients. In order to investigate the potential correlation between d-amino acids and Alzheimer's disease, a simple and sensitive ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed. The method was applied to simultaneous determination of 11 d-amino acids in different regions of rat brain. Rat brain homogenates were firstly pretreated with protein precipitation procedure and then derivatized with (S)-N-(4-nitrophenoxycarbonyl) phenylalanine methoxyethyl ester [(S)-NIFE]. Baseline separation of the derivatives was achieved on an ACQUITY UPLC BEH C 18 column (2.1 mm×50mm, 1.7μm). The mobile phase consisted of acetonitrile and water (containing 8mM ammonium hydrogen carbonate) and the flow rate was 0.6mLmin -1 . The derived analytes were sensitively detected by multiple reaction monitoring in the positive ion mode. The lower limits of quantitation ranged from 0.06 to 10ngmL -1 with excellent linearity (r≥0.9909). The intra- and inter-day RSD were in the range of 3.6-12% and 5.7-12%, respectively. The recovery rate was 82.5%-95.3%. With this UPLC-MS/MS method, the 11 d-amino acids in hippocampus, cerebral cortex, olfactory bulb and cerebellum from Alzheimer's disease rats and age-matched controls could be simultaneously determined. Compared with the normal controls, the concentrations of d-serine, d-alanine, d-leucine, and d-proline in hippocampus and cerebral cortex of Alzheimer's disease rat brain were significantly decreased, while no differences in olfactory bulb and cerebellum of all the d-amino acids were observed. The different amounts and distribution of d-amino acids in brain between the two groups, which regulated by particular pathological changes of Alzheimer's disease, would give new insights into further study in neuropathogenesis and provide novel therapeutic targets of Alzheimer's disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Chen, Mengchun; Zhang, Xiaoqian; Wang, Hao; Lin, Baoli; Wang, Shuanghu; Hu, Guoxin
2015-04-01
A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS-MS) method for the determination of rutin in rat plasma was developed and validated. After addition of tolbutamide as internal standard (IS), protein precipitation by acetonitrile was used as sample preparation. The chromatographic separation was performed on an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm particle size), using acetonitrile-0.1% formic acid as the mobile phase with gradient elution, delivered at a flow-rate of 0.4 mL/min. Mass spectrometric analysis was performed using a XEVO TQD mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 610.91→302.98 and m/z 271.2→155.1 were used to quantify for rutin and tolbutamide, respectively. This assay method has been fully validated in terms of specificity, linearity, recovery and matrix effect, accuracy, precision and stability. Calibration curves were linear in the concentration ranges of 25-2000 ng/mL for rutin. Only 3 min was needed for an analytical run. This developed method was successfully used for determination of rutin in rat plasma for pharmacokinetic study. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zhou, Yao; Yang, Huiqin; Shi, Yiyin; Chen, Jiaxian; Zhu, Jian; Deng, Xiaojun; Guo, Dehua
2017-09-08
A method was developed for the simultaneous determination of six strobilurin fungicide ( E -metominostrobin, azoxystrobin, kresoxim-methyl, picoxystrobin, pyraclostrobin and trifloxystrobin) residues in orange, banana, apple and pineapple samples by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The fragmentation routes of all the compounds were explained by the aid of a fragment predicting software ACD Lab/MS Fragmenter. The samples were extracted by acetonitrile, then cleaned up by amino solid phase extraction cartridges (SupelClean LC-NH 2 ). The extracts were separated on a ACQUITY UPLC BEH C 18 column (50 mm×2.1 mm, 1.7 μm) with gradient elution. Acetonitrile containing 0.1% (v/v) formic acid and 10 mmol/L ammonium acetate containing 0.1% (v/v) formic acid were used as mobile phases. The samples were detected by electrospray ionization (ESI)-MS/MS in positive ion and multiple reaction monitoring (MRM) mode, quantified by external standard method. Good linearities were obtained in the range of 5-100 μg/L (for pyraclostrobin, 1-20 μg/L) with correlation coefficients ( r 2 ) greater than 0.999. The recoveries ranged from 60.4% to 120% with the relative standard deviations between 2.15% and 15.1% ( n =6). The developed method can meet the inspection of the six strobilurin residues in the orange, banana, apple and pineapple samples.
Janzen, Nils; Sander, Stefanie; Terhardt, Michael; Steuerwald, Ulrike; Peter, Michael; Das, Anibh M; Sander, Johannes
2011-12-11
Newborn screening for congenital adrenal hyperplasia (CAH) is usually done by quantifying 17α-hydroxyprogesterone using immunoassay. However, this test produces high rates of false positive results caused by cross reacting steroids. Therefore we have developed a selective and specific method with a short run time (1.25 min) for quantification of 17α-hydroxyprogesterone, 21-deoxycortisol, 11-deoxycortisol, 11-deoxycorticosterone and cortisol from dried blood spots. The extraction procedure is very simple and steroid separation is ensured on a BEH C18 column and an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Analysis was done in positive ionization mode (ESI+) and recorded in multiple reaction monitoring mode (MRM). The method gave linear results for all steroids over a range of 5-200 (cortisol: 12.5-500)nmol/L with coefficients of regression >0.992. Absolute recovery was >64.1%. Across the analytical range the inter-assay coefficient of variation (CV) was <3%. Newborn blood samples of patients with confirmed 21-CAH and 11-CAH could clearly be distinguished from samples of unaffected newborns falsely positive on immunoassay. The method is not influenced by cross reactions as found on immunoassay. Analysis of dried blood spots shows that this method is sensitive and fast enough to allow rapid analysis and can therefore improve the newborn screening program. Copyright © 2011 Elsevier Inc. All rights reserved.
Gou, Xinlei; Gao, Xia; Hu, Guanghui; Chi, Haitao; Le, Shengfeng; Wang, Wei; Liu, Weili
2014-09-01
A sensitive method was developed for the simultaneous determination of 11 bisphenols in plastic bottled drinking water by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The samples were freeze-dried under vacuum and then dissolved with methanol. The separation was performed on a UPLC BEH C18 column (100 mm x 2.1 mm, 1.7 μm) by using 0.1% (v/v) NH3 · H2O and methanol as mobile phases with gradient elution at a flow rate of 0.2 mL/min. The electrospray ionization (ESI) source in negative ion mode was used for the analysis of the 11 bisphenols in the multiple reaction monitoring (MRM) mode. The results verified that the standard curves for the 11 bisphenols were obtained with good correlation coefficients (R2) > 0.997 in their concentration ranges. The limits of detection (LOD, S/N = 3) for the 11 bisphenols were in the range of 0.01-1.00 μg/L. The mean recoveries for the 11 bisphenols at three spiked levels (low, middle, high) were 75.3%-102.1% with the relative standard deviations of 1.5%-8.9%. Seven plastic bottled drinking water samples were tested, and no bisphenol was found. The method is accurate, simple, rapid and feasible for the simultaneous determination of bisphenols in plastic bottled drinking water.
Li, Zhaoyong; Wang, Fengmei; Niu, Zengyuan; Luo, Xin; Zhang, Gang; Chen, Junhui
2014-05-01
A method of ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry (UPLC-LTQ/Orbitrap MS) was established to screen and confirm 24 hormones in cosmetics. Various cosmetic samples were extracted with methanol. The extract was loaded onto a Waters ACQUITY UPLC BEH C18 column (50 mm x 2.1 mm, 1.7 microm) using a gradient elution of acetonitrile/water containing 0.1% (v/v) formic acid for the separation. The accurate mass of quasi-molecular ion was acquired by full scanning of electrostatic field orbitrap. The rapid screening was carried out by the accurate mass of quasi-molecular ion. The confirmation analysis for targeted compounds was performed with the retention time and qualitative fragments obtained by data dependent scan mode. Under the optimal conditions, the 24 hormones were routinely detected with mass accuracy error below 3 x 10(-6) (3 ppm), and good linearities were obtained in their respective linear ranges with correlation coefficients higher than 0.99. The LODs (S/N = 3) of the 24 compounds were < or = 10 microg/kg, which can meet the requirements for the actual screening of cosmetic samples. The developed method was applied to screen the hormones in 50 cosmetic samples. The results demonstrate that the method is a useful tool for the rapid screening and identification of the hormones in cosmetics.
Huang, Xiaochen; Su, Shulan; Cui, Wenxia; Liu, Pei; Duan, Jin-ao; Guo, Jianming; Li, Zhenhao; Shang, Erxin; Qian, Dawei; Huang, Zhijun
2014-07-01
In this present study, a sensitive and rapid UPLC-MS/MS method was developed for simultaneous quantification of paeoniflorin, albiflorin, ferulic acid, tetrahydropalmatine, protopine, typhaneoside and senkyunolide I in Beagle dog plasma after oral administration of the Shao-Fu-Zhu-Yu Decoction. Chloramphenicol and clarithromycin were used as internal standards. Plasma samples were processed by protein precipitation with methanol. The separation was performed on an Acquity BEH C18 column (100mm×2.1mm, 1.7μm) at a flow-rate of 0.4mL/min, using 0.1% formic acid-acetonitrile as mobile phase. Method validation was performed as per Food and Drug Administration guidelines and the results met the acceptance criteria. After validation, this method was successfully applied to a pharmacokinetic study. The results showed that the apparent plasma clearance of paeoniflorin, albiflorin, typhaneoside and senkyunolide I were significantly higher than others. Double peak was observed in plasma concentration curves of tetrahydropalmatine, the ferulic acid had a good absorption in Beagle dog plasma, and senkyunolide I was detected in plasma from the first blood sampling time (15min) and rapidly reached Tmax. The compound of typhaneoside has a low bioavailability according to the results. Copyright © 2014. Published by Elsevier B.V.
Shan, Xiao Mei; Shen, Deng Hui; Wang, Bing Shuang; Lu, Bei Bei; Huang, Fa Yuan
2014-06-01
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0 μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%. Relative standard deviations (RSDs) were between 1.26% and 3.67%. Applying this method to detect the source water of Chaohu Lake and drinking water of Hefei, six target compounds were detected in different levels. This method is simple with high sensitivity and selectivity, could be suitable for the determination of these compounds in source and drinking water. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
El-Bagary, Ramzia; Hashem, Hanaa; Fouad, Marwa; Tarek, Sally
2016-09-01
A sensitive, rapid and simple liquid chromatographic-electrospray ionization tandem mass spectrometric (LC-ESI-MS-MS) method was developed for the quantitative determination of vilazodone in human plasma and for the study of the pharmacokinetic behavior of vilazodone in healthy Egyptian volunteers. With escitalopram as internal standard (IS), liquid-liquid extraction was used for the purification and preconcentration of analytes from human plasma matrix using diethyl ether. The separation was performed on an Acquity UPLC BEH shield RP C18 column (1.7 µm, 2.1 × 150 mm). Isocratic elution was applied using methanol-0.2% formic acid (90:10, v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer with multiple reaction monitoring mode via an electrospray ionization source at m/z 442.21 → 155.23 for vilazodone and m/z 325.14 → 109.2 for escitalopram. Linear calibration curves were obtained over the range of 1-200 ng/mL with the lower limit of quantification at 1 ng/mL. The intra- and inter-day precision showed relative standard deviation ≤3.3%. The total run time was 1.5 min. This method was successfully applied for clinical pharmacokinetic investigation, and a preliminary metabolic study was also carried out. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Hydrophilic interaction chromatography (HILIC) in the analysis of antibiotics.
Kahsay, Getu; Song, Huiying; Van Schepdael, Ann; Cabooter, Deirdre; Adams, Erwin
2014-01-01
This paper presents a general overview of the application of hydrophilic interaction chromatography (HILIC) in the analysis of antibiotics in different sample matrices including pharmaceutical, plasma, serum, fermentation broths, environmental water, animal origin, plant origin, etc. Specific applications of HILIC for analysis of aminoglycosides, β-lactams, tetracyclines and other antibiotics are reviewed. HILIC can be used as a valuable alternative LC mode for separating small polar compounds. Polar samples usually show good solubility in the mobile phase containing some water used in HILIC, which overcomes the drawbacks of the poor solubility often encountered in normal phase LC. HILIC is suitable for analyzing compounds in complex systems that elute near the void in reversed-phase chromatography. Ion-pair reagents are not required in HILIC which makes it convenient to couple with MS hence its increased popularity in recent years. In this review, the retention mechanism in HILIC is briefly discussed and a list of important applications is provided including main experimental conditions and a brief summary of the results. The references provide a comprehensive overview and insight into the application of HILIC in antibiotics analysis. Copyright © 2013 Elsevier B.V. All rights reserved.
Tissue Multiplatform-Based Metabolomics/Metabonomics for Enhanced Metabolome Coverage.
Vorkas, Panagiotis A; Abellona U, M R; Li, Jia V
2018-01-01
The use of tissue as a matrix to elucidate disease pathology or explore intervention comes with several advantages. It allows investigation of the target alteration directly at the focal location and facilitates the detection of molecules that could become elusive after secretion into biofluids. However, tissue metabolomics/metabonomics comes with challenges not encountered in biofluid analyses. Furthermore, tissue heterogeneity does not allow for tissue aliquoting. Here we describe a multiplatform, multi-method workflow which enables metabolic profiling analysis of tissue samples, while it can deliver enhanced metabolome coverage. After applying a dual consecutive extraction (organic followed by aqueous), tissue extracts are analyzed by reversed-phase (RP-) and hydrophilic interaction liquid chromatography (HILIC-) ultra-performance liquid chromatography coupled to mass spectrometry (UPLC-MS) and nuclear magnetic resonance (NMR) spectroscopy. This pipeline incorporates the required quality control features, enhances versatility, allows provisional aliquoting of tissue extracts for future guided analyses, expands the range of metabolites robustly detected, and supports data integration. It has been successfully employed for the analysis of a wide range of tissue types.
Gritti, Fabrice; Guiochon, Georges
2013-07-05
The effective diffusion coefficients of five low molecular weigh compounds (naphthalene, uracil, uridine, adenosine, and cytosine) were measured at room temperature in a 4.6mm×100mm column packed with 3.5μm XBridge HILIC particles. The mobile phase was an acetonitrile-water mixture (92.5/7.5, v/v) containing 10mM ammonium acetate and 0.02% acetic acid. Using a physically reliable model of effective diffusion in binary composite media (Torquato's model), accurate estimates of the intra-particle diffusivities in the HILIC particles were obtained as a function of the retention of these analytes. The HILIC diffusion coefficients were compared to those previously obtained for endcapped RPLC-C18 particles (5.0μm Gemini-C18). The experimental results confirm that adsorption sites are not localized in RPLC whereas they are so in the HILIC mode. In contrast to RPLC columns, HILIC columns provide longitudinal diffusion B/u terms that increase very little with increasing retention factors. This confirms the absence of surface diffusion in HILIC. The impact of intra-particle diffusivity on the column efficiency was projected in HILIC and RPLC on the basis of the measured intra-particle diffusivities and on the well established theory of band broadening in particulate columns. Accordingly, RPLC columns generate short-range eddy dispersion and solid-liquid mass transfer resistance Cu terms that increase less than do HILIC column with increasing retention factors. The HETP contribution caused by the trans-column structure heterogeneity is smaller in the HILIC than in the RPLC modes because the transverse excursion length is smaller in HILIC. Even though the overall column efficiencies are comparable in HILIC and RPLC, this study shows that the individual mass transfer phenomena are inherently different in the HILIC and the RPLC retention modes. Copyright © 2013 Elsevier B.V. All rights reserved.
Madhukar, Garg; Tamboli, Ennus Tajuddin; Rabea, Parveen; Ansari, S. H.; Abdin, M. Z.; Sayeed, Ahmad
2014-01-01
Background: Adhatoda vasica a perennial herb has been used in Ayurvedic and Unani system of medicines since last 2000 years and has been employed for the treatment of respiratory tract ailments. Objective: To develop and validate new, rapid, and highly sensitive high throughput ultra-performance liquid chromatography/quadrupole-time-of-flight mass-spectrometry (UPLC/Q-TOF-MS) method for the quantitative estimation of vasicine in the leaves and to establish in vitro cultures of Adhatoda vasica for production of vasicine. Materials and Methods: The chromatographic separation was achieved on a Waters ACQUITY UPLC™ BEH C8 (100.0 × 2.1 mm; 1.7 μm) column packing using isocratic mobile phase consisting of acetonitrile: 20 mM ammonium acetate (90:10; v/v) in a multiple reactions monitoring mode using the transitions m/z 189.09 → 171.08 for vasicine. Results: The vasicine was eluted at 2.58 ± 0.05 min and established a dynamic range of linearity over the concentration range of 1-1000 ng/ml (r2 = 0.999 ± 0.0005). The lower limit of detection and quantification was 0.68 and 1.0 ng/ml, respectively. There was no significant difference observed in the content of vasicine (0.92-1.04%w/w) among the eleven samples collected from different locations of India. The in vitro cultures developed showed that addition of extra 28 mM KNO3 and 100 mM NaCl in MS medium supplemented with 2,4-dichlorophenoxyacetic acid (2,4-D) + benzyladenine (BA) + indole acetic acid (IAA) (1 ppm each) produces faster biomass and higher amount of quinazoline alkaloids. Conclusion: Rapid, efficient, and sensitive UPLC/Q-TOF-MS method was developed for the estimation of vasicine and an efficient protocol for development of in vitro cultures was proposed, which can be used at large scale for industrial production of vasicine using bioreactors. PMID:24914304
A, Vijaya Bhaskar Reddy; Yusop, Zulkifli; Jaafar, Jafariah; Aris, Azmi B; Majid, Zaiton A; Umar, Khalid; Talib, Juhaizah
2016-09-05
In this study a sensitive and selective gradient reverse phase UPLC-MS/MS method was developed for the simultaneous determination of six process related impurities viz., Imp-I, Imp-II, Imp-III, Imp-IV, Imp-V and Imp-VI in darunavir. The chromatographic separation was performed on Acquity UPLC BEH C18 (50 mm×2.1mm, 1.7μm) column using gradient elution of acetonitrile-methanol (80:20, v/v) and 5.0mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4mL/min. Both negative and positive electrospray ionization (ESI) modes were operated simultaneously using multiple reaction monitoring (MRM) for the quantification of all six impurities in darunavir. The developed method was fully validated following ICH guidelines with respect to specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, robustness and sample solution stability. The method was able to quantitate Imp-I, Imp-IV, Imp-V at 0.3ppm and Imp-II, Imp-III, and Imp-VI at 0.2ppm with respect to 5.0mg/mL of darunavir. The calibration curves showed good linearity over the concentration range of LOQ to 250% for all six impurities. The correlation coefficient obtained was >0.9989 in all the cases. The accuracy of the method lies between 89.90% and 104.60% for all six impurities. Finally, the method has been successfully applied for three formulation batches of darunavir to determine the above mentioned impurities, however no impurity was found beyond the LOQ. This method is a good quality control tool for the trace level quantification of six process related impurities in darunavir during its synthesis. Copyright © 2016 Elsevier B.V. All rights reserved.
Kok, Miranda G M; Somsen, Govert W; de Jong, Gerhardus J
2015-01-01
In order to assess the utility of a recently developed capillary electrophoresis-mass spectrometry (CE-MS) method for the study of anionic metabolites in urine, a comparison was made with hydrophilic interaction chromatography-MS (HILIC-MS) using negative electrospray ionization. After optimization of the HILIC conditions, a gradient employing 10mM ammonium acetate (pH 6.8) in acetonitrile-water (5 min 90% acetonitrile followed by 90%-50% acetonitrile in 10 min) was selected, providing baseline separation of five representative anionic test metabolites. Relative standard deviations (RSDs) for HILIC retention times and peak areas were below 0.2% and 7.7%, respectively, and detection limits were in the range 0.04-2.21 μM. Metabolites in rat urine could also be analysed in a reproducible way with retention time and peak area RSDs below 0.6% and 13.6%, respectively. The CE-MS and HILIC-MS methods were compared in terms of reproducibility, sensitivity, selectivity and coverage of the anionic urinary metabolome. In general, peak area RSDs were similar whereas HILIC-MS yielded better retention-time repeatability and up to 80 times lower detection limits (expressed in injected concentration) for test metabolites as compared to CE-MS. Rat urine analysis by HILIC-MS provided detection of 1360 molecular features compared to 347 molecular features revealed with CE-MS. Of these, a number of 144 molecular features were found with both HILIC-MS and CE-MS, which showed on average 10 times higher peak areas in HILIC-MS. The HILIC retention and CE migration times of the common features were clearly not correlated. The HILIC and CE behavior of the test metabolites and 16 putatively identified common features were evaluated involving their physicochemical properties, indicating a markedly different separation selectivity, and thus significant degree of orthogonality of HILIC and CE. Copyright © 2014 Elsevier B.V. All rights reserved.
Kubica, Paweł; Namieśnik, Jacek; Wasik, Andrzej
2016-08-05
Hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass spectrometry (MS/MS) was used to separate artificial and natural sweeteners approved for use in European Union (EU). Among three tested HILIC columns (BlueOrchid PAL-HILIC, Ascentis Express Si and Acclaim™ Trinity™ P2) the last one was selected for the development of HILIC method due to the best results obtained with it. Early eluting and coeluting compounds in HILIC (acesulfame-K, saccharin, cyclamate, sucralose and aspartame) were successfully separated by the HILIC-based approach for the first time. The developed HILIC method allows for determination of all high potency sweeteners in one analytical run. The calibration curves for all analytes had good linearity within the tested ranges. The limits of detection and quantitation were in the range 0.81-3.30ng/mL and 2.32-9.89ng/mL, respectively. The obtained recoveries used for trueness and precision estimation were from 98.6% to 106.2% with standard deviation less than 4.1%. Sample preparation was reduced to a necessary minimum and contained only proper dilution and centrifugation. More than twenty samples of beverages were analyzed with the developed HILIC method. Finally, the chromatographic parameters of peaks (reduced retention time, width at baseline, width at 50% of peak height, tailing factor and efficiency) obtained in HILIC mode and in RPLC mode were compared. Developed HILIC method along with RPLC method can be applied for rapid evaluation of sweeteners' content, quality and safety control. Copyright © 2016 Elsevier B.V. All rights reserved.
Siddiqui, Masoom Raza; Wabaidur, Saikh Mohammad; Khan, Moonis Ali; ALOthman, Zeid A; Rafiquee, M Z A; Alqadami, Ayoub Abdullah
2018-01-01
Quantitative assessment of nitrite (NO 2 - ) anion was performed using a newly developed high throughput ultra performance liquid chromatography-mass spectrometric (UPLC-MS) method. The nitrite determination with the proposed method using micellar mobile phase was unknown. Selected ion reaction mode using negative electrospray ionization was adopted for the identification and quantitative analysis of nitrite. The chromatographic separation was performed using BEH C-18 column and a micellar mobile phase consisted of sodium dodecyl sulphate and acetonitrile in ratio 30:70 was used. The elution of nitrite anion was accomplished in less than 1 min. Under the optimal analysis conditions, the linearity of the developed method was checked in the concentration range of 0.5-20 mg kg -1 NO 2 - with an excellent correlation coefficient of 0.996. The precisions of the method with relative standard deviation <2% was observed when standard at concentration of 1 mg kg -1 was used. The limit of detection and limit of quantitation of the developed mass spectrometric method was found to be 0.114 and 0.346 mg kg -1 , respectively. The developed UPLC/MS method was applied to quantify this anion in processed meats and poultries from various super market of Saudi Arabia (Riyadh region). The recoveries of the nitrite in the various samples were found in the range of 100.03-103.5%.
Wang, Ying; Xu, Ranchi; Xiao, Juan; Zhang, Jian; Wang, Xinhong; An, Rui; Ma, Yueming
2014-01-01
Banxia Xiexin decoction (BXD) is an effective Chinese Medicinal Prescription in treating gastroenteritis diseases. In this study an ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed to separate and determine 18 major active ingredients of BXD in order to guarantee quality. The separation of ten flavonoids, four alkaloids and four saponins was accomplished on an Acquity BEH C18 (2.1mm×100mm, 1.7μm) column using gradient elution with 0.1% (v/v) formic acid water (A) and 0.1% (v/v) formic acid in methanol (B). All the analytes were detected in positive electrospray ionization tandem mass spectrometry by selective reaction monitoring (SRM) mode. A good linear regression relationship for each analyte was obtained over the range from 2.41-438ng/ml to 20.75-4150ng/ml. The precision was evaluated by intra- and inter-day assays with relative standard deviation (RSD) less than 7.7%. The recovery measured at three concentration levels varied from 92.4% to 107.8%. The method sensitivity expressed as LOQ was typically 0.97-4.15ng/ml. The assay was successfully applied for determination of the 18 bioactive compounds in BXD. The results indicated that the new UPLC-MS/MS method was rapid and accurate, and could be reliably utilized as a quality control method for BXD. Copyright © 2013 Elsevier B.V. All rights reserved.
Wang, Haidong; Yang, Guangsheng; Zhou, Jinyu; Pei, Jiang; Zhang, Qiangfeng; Song, Xingfa; Sun, Zengxian
2016-08-01
In this study, a simple and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for quantitation of droxidopa in human plasma for the first time. A simple plasma protein precipitation method using methanol containing 3% formic acid was selected, and the separation was achieved by an Acquity UPLC™ BEH Amide column (2.1mm×50mm, 1.7μm) with a gradient elution using acetonitrile, ammonium formate buffer and formic acid as mobile phase. The detection of droxidopa and benserazide (internal standard, IS) was performed using positive-ion electrospray tandem mass spectrometry via multiple reaction monitoring (MRM). The precursor-to-product ion transitions m/z 214.2→m/z 152.0 for droxidopa, and m/z 258.1→m/z 139.1 for IS were used for quantification. A lower limit of quantification of 5.00ng/mL was achieved and the linear curve range was 5.00-4000ng/mL using a weighted (1/x(2)) linear regression model. Intra-assay and inter-assay precision was less than 10.2%, and the accuracy ranged from 0.1% to 2.1%. Stability, recovery and matrix effects were within the acceptance criteria recommended by the regulatory bioanalytical guidelines. The method was successfully applied to a pharmacokinetic study of droxidopa in healthy Chinese volunteers. Copyright © 2016. Published by Elsevier B.V.
Wang, Shuo; Zhang, Xiangming; Zhang, Jing; Shao, Bing; Li, Shuming
2015-07-01
A method for the determination of 54 drugs in drinking water samples was developed by using ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI MS/MS). The target drugs in drinking water samples were enriched and cleaned-up by HLB solid-phase extraction (SPE) cartridges and then eluted with 5 mL methanol. The elute was collected, concentrated under a gentle stream of nitrogen gas, diluted with 0.4 mL 0.1% formic acid solution, and analyzed by UPLC-ESI MS/MS. The separation of the 54 drugs was performed on an ACQUITY UPLC™ BEH C18 column using mobile phases of 0.1% formic acid and methanol by gradient elution. The multiple reaction monitoring (MRM) mode was employed in mass spectrometry acquisition. The matrix-matched external standard calibration was used for quantitation. The results showed that the average recoveries of the drugs in ground water, tap water and surface water were 58.7%-104.4%, 53.1%-109.5%, and 50.7%-118.8%, respectively, and the corresponding relative standard deviations (RSD, n=6) were 0.3%-12.8%, 1.0%-15.5%, and 0.4%-19.3%, respectively. The method quantification limits (MQL) for target compounds were in the range of 0.002-5.000 ng/L. The developed method was applied to analyze the water samples from Beijing. The results showed that 26 drugs were detected in ground water samples.
Wang, Tianjiao; Wu, Pinggu; Hu, Zhengyan; Wang, Liyuan; Tang, Jun; Jiang, Wei; Wang, Zhiyuan
2016-07-01
To establish a new qualitative and quantitative ultraperformance liquid chromatography-fluorescence detector / photodiode array detector with series double-detector method for the determination of eleven fluorescent whitening agents in paper food packaging materials. The sample was extracted with 40%acetonitrile water solution, separated by Waters ACQUITY UPLC BEH C_(18)column( 1. 7μm, 2. 1 mm × 100 mm) and eluted gradient. The excitation wavelength and emission wavelength of fluorescence detector( FLD) were 350 nm and 430 nm, and the wavelength of photodiode array detector( PDA) was 350 nm. The detectors were used in series to achieve qualitative and quantitative detection. In the substrates of paper cups, paper bowls, paper trays and paper boxes, those eleven fluorescent whitening agents were separated properly. For both detectors, in the linear range of 25- 1000 ng / m L, the correlation coefficient was greater than 0. 99, and the recoveries of spiked recoveries were between 82. 2%- 104. 1% with the RSD less than 10%( n = 6). The detection limits ofthose eleven fluorescent whitening agents were 0. 20- 0. 28 mg / kg for FLD and 1. 4- 2. 5mg / kg for PDA. The eleven fluorescent whitening agents could be separated properly with complete separation, good shapes and high recovery rate. This method is easy to operate also. Thus it's an effective method to detect the fluorescent whitening agents in paper food packaging materials.
Wang, Lijuan; Ke, Runhui; Wang, Bing; Yin, Jianjun; Song, Quanhou
2012-09-01
An ultra performance liquid chromatography-electrospray ionization tandem mass spectrometric (UPLC-ESI-MS/MS) method was established for the direct determination of ethyl carbamate in Chinese rice wine and grape wine. The Chinese rice wine and grape wine samples were diluted with distilled water, filtered through 0. 22 microm microporous membrane. The LC separation was performed on a Waters Acquity UPLC system with a BEH C18 column, acetonitrile and 0. 1% (v/v) acetic acid aqueous solution as the mobile phase. The ethyl carbamate was determined in the mode of electrospray positive ionization (ESI+) and multiple reaction monitoring (MRM). The butyl carbamate (BC) was used as the internal standard for the quantitative determination. The calibration curve showed good linearity in the range of 2 - 500 microg/L with the correlation coefficient greater than 0.995. The limit of detection (LOD) was 1.7 microg/L and the limit of quantification (LOQ) was 5.0 microg/L. The recoveries of the ethyl carbamate in Chinese rice wine and grape wine was in the range of 90% - 102%. The relative standard deviations (RSDs) of intra-day and inter-day determinations were 0. 8% - 4.5% and 1.4% - 5.6% (n = 6). The results indicated that the proposed method is easy, fast, sensitive, and suitable for the determination of ethyl carbamate in Chinese rice wine and grape wine.
A simple graphical representation of selectivity in hydrophilic interaction liquid chromatography.
Ibrahim, Mohammed E A; Liu, Yang; Lucy, Charles A
2012-10-19
This paper uses the HILIC selectivity data of Dinh et al. (J. Chromatogr. A 1218 (2011) 5880) to yield simple and easy to understand plots analogous to Neue plots for selectivity in HILIC. The plots categorize 21 previously studied HILIC phases (data from Dinh et al.), 8 additional HILIC columns and 4 reversed phase columns (our data) using selected probes for specific interactions. The relative retention of cytosine vs. uracil is used to probe the "hydrophilicity" of the HILIC phases; adenosine vs. adenine is used to probe the ability of the stationary phase to participate in hydrogen bonding; and benzyltrimethylammonium (BTMA) vs. cytosine is used to probe the cation exchange and anion exchange character of the column. Plots of kBTMA/kcytosine vs. kcytosine/kuracil successfully classify silica, amide, zwitterionic, diol and reverse phase columns in terms of their HILIC behavior. Polymeric columns including polymer substrate and polymer coated columns show low ion exchange character, but vary widely in their hydrophilicity. Alternatively a HILIC-Phase Selectivity Chart, in analogy to the Neue plot, is constructed by plotting log(kBTMA/kcytosine) vs. log(kcytosine). This plot enables classification of HILIC columns that will yield similar or significantly different separations. Copyright © 2012 Elsevier B.V. All rights reserved.
Wang, Manman; Wang, Lijuan; Sun, Jinghan; Zhang, Lili; Zhao, Longshan; Xiong, Zhili
2018-03-01
A specific, rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method was developed for simultaneous determination of vinpocetine (VP) and its active metabolite, apovincaminic acid (AVA) in rat brain regions, such as hypothalamus, striatum, cortex, cerebellum and hippocampus. Phenacetin was used as internal standard (IS). Brain tissue samples were precipitated protein by using 500 μL methanol. The separation was achieved on a Waters ACQUITY UPLC BEH C18 column (100 mm × 2.1 mm, 1.7 μm), using a methanol-water gradient elution at the flow rate of 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring (MRM) mode via positive electrospray ionization source (ESI). The quantification was operated using the transitions of m/z 351 → m/z 280 for VP, m/z 323 → m/z 280 for AVA and m/z 180 → m/z 110 for IS, respectively. The calibration curve was linear in concentration range from 0.100 to 60.0 ng/mL for VP and 0.103 to 6.18 ng/mL for AVA. The intra-day and inter-day precision (relative standard deviation, RSD) values were within 11.8%, the accuracy (relative error, RE) was from -1.7% to 3.0% for VP and 2.7% to 9.5% for AVA at all the three concentration levels of quality-control (QC) samples. The improved UPLC-MS/MS method was specific, rapid and sensitive, which was further successfully applied to simultaneous determination of VP and AVA in different rat brain regions after intragastric administration of 4 mg/kg VP. It was indicated that VP could be eliminated quickly in brain, while the elimination of AVA was slow and it could be maintained for more than 12 h in brain. Moreover, it was found that the contents of VP and AVA were much higher in the hypothalamus, striatum and cortex than those in the cerebellum and hippocampus, which verified the distribution characteristics of VP and AVA in different brain regions from the point of quantitation in rats.
Song, Huiying; Desmet, Gert; Cabooter, Deirdre
2017-11-10
A recently developed stripping protocol to completely remove the stationary phase of reversed-phase liquid chromatography (RPLC) columns and turn them into hydrophilic interaction liquid chromatography (HILIC) columns with identical packing characteristics is used to study the underlying mechanisms of intra-particle diffusion in RPLC and HILIC. The protocol is applied to a column with a large geometrical volume (250×4.6mm, 5μm) to avoid extra-column effects and for compounds with a broad range in retention factors (k" from ∼0.6 to 8). Three types of behavior for the intra-particle diffusion (D part /D m ) in RPLC versus HILIC can be distinguished: for nearly unretained compounds (k"<0.6), intra-particle diffusion in HILIC is larger than in RPLC; for compounds with intermediate retention behavior (k"∼0.9-1.2), intra-particle diffusion in HILIC and RPLC are similar; and for well retained compounds (k">1.8), intra-particle diffusion in RPLC is larger than in HILIC. To explain these observations, diffusion in the stationary phase (γ s D s ) and in the stagnant mobile phase in the mesopore zone (γ mp D m ) are deduced from experimentally determined values of the intra-particle diffusion, using models derived from the Effective Medium Theory. It is demonstrated that the larger intra-particle diffusion obtained for slightly retained compounds under HILIC conditions is caused by the higher mesopore diffusion in HILIC (γ mp =0.474 for HILIC versus 0.435 for RPLC), while the larger intra-particle diffusion obtained for strongly retained compounds under RPLC conditions can be related to the much higher stationary phase diffusion in RPLC (γ s D s /D m =0.200 for RPLC versus 0.113 for HILIC). Copyright © 2017 Elsevier B.V. All rights reserved.
Yang, Wei; Laaksonen, Oskar; Kallio, Heikki; Yang, Baoru
2017-02-01
Sea buckthorn (Hippophaë rhamnoides ssp. rhamnoides) of varieties 'Terhi' and 'Tytti' and one of wild origin were cultivated in southern and northern Finland, harvested during 2007-2013. Proanthocyanidins (PAs) were analyzed with HILIC UPLC-ESI-MS. The southern and northern samples were separated in the partial least squares discriminant analysis model (four factors, R(2) 0.75, Q(2) 0.70). The total PAs were more abundant in berries from the north (610-970mg/100gDW) than in those from the south (340-450mg/100gDW) (p<0.05). In northern Finland, the length of the growth season as well as the temperature sum and radiation sum of the growth season until harvest were negatively correlated with the total PAs in all the samples but positively with PA oligomers in 'Tytti' and 'Terhi'. In southern Finland no respective correlations were seen. 'Terhi' and 'Tytti' had different trends in the content of total PA and oligomers in overripe stages. Copyright © 2016 Elsevier Ltd. All rights reserved.
Alagesan, Kathirvel; Khilji, Sana Khan; Kolarich, Daniel
2017-01-01
Glycopeptide enrichment is a crucial step in glycoproteomics for which hydrophilic interaction chromatography (HILIC) has extensively been applied due to its low bias towards different glycan types. A systematic evaluation of applicable HILIC mobile phases on glycopeptide enrichment efficiency and selectivity is, to date, however, still lacking. Here, we present a novel, simplified technique for HILIC enrichment termed "Drop-HILIC", which was applied to systematically evaluate the mobile phase effect on ZIC-HILIC (zwitterionic type of hydrophilic interaction chromatography) glycopeptide enrichment. The four most commonly used MS compatible organic solvents were investigated: (i) acetonitrile, (ii) methanol, (iii) ethanol and (iv) isopropanol. Glycopeptide enrichment efficiencies were evaluated for each solvent system using samples of increasing complexity ranging from well-defined synthetic glycopeptides spiked into different concentrations of tryptic BSA peptides, followed by standard glycoproteins, and a complex sample derived from human (depleted and non-depleted) serum. ZIC-HILIC glycopeptide efficiency largely relied upon the used solvent. Different organic mobile phases enriched distinct glycopeptide subsets in a peptide backbone hydrophilicity-dependant manner. Acetonitrile provided the best compromise for the retention of both hydrophilic and hydrophobic glycopeptides, whereas methanol was confirmed to be unsuitable for this purpose. The enrichment efficiency of ethanol and isopropanol towards highly hydrophobic glycopeptides was compromised as considerable co-enrichment of unmodified peptides occurred, though for some hydrophobic glycopeptides isopropanol showed the best enrichment properties. This study shows that even minor differences in the peptide backbone and solvent do significantly influence HILIC glycopeptide enrichment and need to be carefully considered when employed for glycopeptide enrichment. Graphical Abstract The organic solvent plays a crucial role in ZIC-HILIC glycopeptide enrichment.
Kang, Jae-Hyun; Kim, Suna; Moon, BoKyung
2016-08-15
In this study, we used response surface methodology (RSM) to optimize the extraction conditions for recovering lutein from paprika leaves using accelerated solvent extraction (ASE). The lutein content was quantitatively analyzed using a UPLC equipped with a BEH C18 column. A central composite design (CCD) was employed for experimental design to obtain the optimized combination of extraction temperature (°C), static time (min), and solvent (EtOH, %). The experimental data obtained from a twenty sample set were fitted to a second-order polynomial equation using multiple regression analysis. The adjusted coefficient of determination (R(2)) for the lutein extraction model was 0.9518, and the probability value (p=0.0000) demonstrated a high significance for the regression model. The optimum extraction conditions for lutein were temperature: 93.26°C, static time: 5 min, and solvent: 79.63% EtOH. Under these conditions, the predicted extraction yield of lutein was 232.60 μg/g. Copyright © 2016 Elsevier Ltd. All rights reserved.
Loukotková, Lucie; VonTungeln, Linda S; Vanlandingham, Michelle; da Costa, Gonçalo Gamboa
2018-01-01
According to the World Health Organization, the consumption of tobacco products is the single largest cause of preventable deaths in the world, exceeding the total aggregated number of deaths caused by diseases such as AIDS, tuberculosis, and malaria. An important element in the evaluation of the health risks associated with the consumption of tobacco products is the assessment of the internal exposure to the tobacco constituents responsible for their addictive (e.g. nicotine) and carcinogenic (e.g. N-nitrosamines such as NNN and NNK) properties. However, the assessment of the serum levels of these compounds is often challenging from an analytical standpoint, in particular when limited sample volumes are available and low detection limits are required. Currently available analytical methods often rely on complex multi-step sample preparation procedures, which are prone to low analyte recoveries and ex-vivo contamination due to the ubiquitous nature of these compounds as background contaminants. In order to circumvent these problems, we report a facile and highly sensitive method for the simultaneous quantification of nicotine, cotinine, NNN, and NNK in serum samples. The method relies on a simple "one pot" liquid-liquid extraction procedure and isotope dilution ultra-high pressure (UPLC) hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass spectrometry. The method requires only 10μL of serum and presents a limit of quantification of 0.02nmol (3000pg/mL) nicotine, 0.6pmol (100pg/mL) cotinine, 0.05pmol NNK (10pg/mL), and 0.06pmol NNN (10pg/mL), making it appropriate for pharmacokinetic evaluations. Published by Elsevier B.V.
Human leukocyte antigen B27 and B51 double-positive Behçet uveitis.
Ahn, Jae Kyoun; Park, Yeoung Geol
2007-10-01
To describe the clinical characteristics of human leukocyte antigen (HLA) B27 and B51 double-positive Behçet uveitis and to determine whether the coexistence of HLA-B27 can affect Behçet uveitis. We retrospectively reviewed the medical records of patients with Behçet uveitis and patients with HLA-B27-associated non-Behçet uveitis who underwent HLA-B27 and HLA-B51 typing and were followed up for more than 3 years. We divided the patients into 3 groups according to HLA-B27/B51 status and compared the clinical outcomes. Main outcome measures were demographic features, uveitis characteristics, complications, treatments, and visual prognosis. Fourteen patients with HLA-B27(+)B51(+) Behçet uveitis, 43 patients with HLA-B27(-)B51(+) Behçet uveitis, and 41 patients with HLA-B27(+)B51(-) non-Behçet uveitis were identified. HLA-B27(+)B51(+) Behçet uveitis showed the demographic features similar to HLA-B27(-) counterparts. However, HLA-B27(+)B51(+) Behçet uveitis showed less involvement of posterior segments, a less chronic course, fewer complications in posterior segments, and less use of systemic medication or surgical intervention for inflammatory control, similar to HLA-B27(+)B51(-) non-Behçet uveitis. The long-term vision prognosis of HLA-B27(+)B51(+) Behçet uveitis was more favorable than that of HLA-B27(-)B51(+) Behçet uveitis. Our results indicate that HLA-B27(+)B51(+) Behçet uveitis is a benign subgroup of Behçet uveitis. The positivity of HLA-B27 may be a good prognostic factor in Behçet uveitis.
Jafari, M; Mirzaie, M; Khodabandeh, M; Rezadoost, H; Ghassempour, A; Aboul-Enein, H Y
2016-07-01
During recent decades, hydrophilic interaction liquid chromatography (HILIC) ahs been introduced to fractionate or purify especially polar solutes such as peptides and proteins while reversed-phase liquid chromatography (RPLC) is also a common strategy. RPLC is also a common dimension in multidimensional chromatography. In this study, the potential of HILIC vs RPLC chromatography was compared for proteome mapping of human peripheral blood mononuclear cell extract. In HILIC a silica-based stationary phase and for RPLC a C18 column were applied. Then separated proteins were eluted to an ion trap mass spectrometry system. Our results showed that the HILIC leads to more proteins being identified in comparison to RPLC. Among the total 181 identified proteins, 56 and 38 proteins were fractionated specifically by HILIC and RPLC, respectively. In order to demonstrate this, the physicochemical properties of identified proteins such as polarity and hydrophobicity were considered. This analysis indicated that polarity may play a major role in the HILIC separation of proteins vs RPLC. Using gene ontology enrichment analysis, it was also observed that differences in physicochemical properties conform to the cellular compartment and biological features. Finally, this study highlighted the potential of HILIC and the great orthogonality of RPLC in gel-free proteomic studies. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Huang, Zongyun; Francis, Robert; Zha, Yan; Ruan, Joan
2015-01-01
A simple, sensitive and robust method using HILIC-ESI-MS has been developed for the determination of methane sulfonic acid (MSA) at low ppm level in order to verify the effectiveness of controlling the formation of genotoxic sulfonate esters in the downstream synthetic step, by which produces active pharmaceutical ingredient (API). Stationary phases with positively charged functional groups such as triazole and amino phases were evaluated for the retention of alkyl sulfonic acids. The MSA was quantitated at 1-10 ppm relative to the API using a Cosmosil column (triazole stationary phase) in HILIC mode and the control of MSA can be monitored effectively using the HILIC-ESI-MS methodology. In addition, to provide general guidance for the HILIC-ESI-MS method development, the retention behavior of propanesulfonic acid (PSA) in HILIC mode was investigated using a Unison UK-Amino column to have a better understanding of the HILIC separation mechanism. The results showed reasonable evidence that the combined effect of surface adsorption and ion-exchange played a dominant role for sulfonic acids when using a mobile phase within typical HILIC operation range (0.05-0.20 aqueous volume fraction) while the ion-exchange effect becomes increasingly important in a mobile phase with higher water content. The advantage of using ESI-MS detection in HILIC mode was also demonstrated by the observation that the sensitivity of PSA increased substantially with increasing acetonitrile fraction in mobile phase from 0.80 to 0.95. Copyright © 2014 Elsevier B.V. All rights reserved.
Lu, Yuejuan; Li, Ning; Deng, Ying; Zhao, Longshan; Guo, Xingjie; Li, Famei; Xiong, Zhili
2015-07-01
A rapid, sensitive and selective ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of icariin, naringin and osthole in rat plasma. Plasma samples pretreatment involved a one-step liquid-liquid extraction with a mixture of ethyl acetate-methyl tert-butyl ether (3:1, ν/ν). The separation was performed on an ACQUITY UPLC™ BEH C18 column with a gradient mobile phase system of methanol and water. The detection was performed on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization (ESI) by multiple reactions monitoring (MRM), with the transitions at m/z 513.3→366.8 (icariin), m/z 579.3→150.9 (naringin), m/z 245.1→189.0 (osthole) and m/z 237.1→194.1 (IS), respectively. A good linear response was observed over the concentration ranges of 1.06-424ng/ml, 2.10-525ng/ml and 1.05-1.05×10(3)ng/ml with lower limit of quantification (LLOQ) of 1.06, 2.10 and 1.05ng/ml for icariin, naringin and osthole, respectively. The intra- and inter-day precisions (R.S.D.) were within 14.3%, and the accuracy (R.E.) ranged from -4.1% to 4.6% at three quality control levels. The sensitive and selective method was applied to a pharmacokinetic study of icarrin, naringin and osthole in rats after oral administration of Gushudan capsule. Copyright © 2015 Elsevier B.V. All rights reserved.
Kryczyk, Agata; Żmudzki, Paweł; Hubicka, Urszula
2016-11-01
A simple and reproducible UPLC-MS/MS method for the determination of itraconazole (ITZ) and its photodegradation products formed during exposure to UV-A radiation was developed. Chromatographic separations were carried out using an Acquity UPLC BEH C 18 column (2.1 × 100 mm, 1.7 μm particle size). The column was maintained at 40°C, and eluted under gradient conditions from 100% to 50% of eluent A over 13 min, at a flow rate of 0.3 mL min -1 . Eluent A was 0.1% (v/v) formic acid in water; eluent B was 0.1% (v/v) formic acid in acetonitrile. The linear regression analysis for the calibration curve showed a good linear correlation over the concentration range 0.0066-0.15 mg mL -1 with determination coefficient > 0.99. The activities of some photocatalysts during degradation process of ITZ were compared. It was found that indirect photodegradation of ITZ was more effective than direct photolysis. Under our experimental conditions the photodegradation rate constant depended on the applied catalysts with catalytic activity decreasing in the following pattern: FeCl 3 > TiO 2 /FeCl 3 > TiO 2 . The kinetic analysis of the photodegradation data revealed that the degradation of the ITZ follows first-order kinetics. The photodegradation products of ITZ were identified, and their fragmentation pathways, derived from MS/MS data, were proposed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Giménez, Estela; Gay, Marina; Vilaseca, Marta
2017-01-30
Here we demonstrate the potential of nano-UPLC-LTQ-FT-MS and the Byonic™ proteomic search engine for the separation, detection, and identification of N- and O-glycopeptide glycoforms in standard glycoproteins. The use of a BEH C18 nanoACQUITY column allowed the separation of the glycopeptides present in the glycoprotein digest and a baseline-resolution of the glycoforms of the same glycopeptide on the basis of the number of sialic acids. Moreover, we evaluated several acquisition strategies in order to improve the detection and characterization of glycopeptide glycoforms with the maximum number of identification percentages. The proposed strategy is simple to set up with the technology platforms commonly used in proteomic labs. The method allows the straightforward and rapid obtention of a general glycosylated map of a given protein, including glycosites and their corresponding glycosylated structures. The MS strategy selected in this work, based on a gas phase fractionation approach, led to 136 unique peptides from four standard proteins, which represented 78% of the total number of peptides identified. Moreover, the method does not require an extra glycopeptide enrichment step, thus preventing the bias that this step could cause towards certain glycopeptide species. Data are available via ProteomeXchange with identifier PXD003578. We propose a simple and high-throughput glycoproteomics-based methodology that allows the separation of glycopeptide glycoforms on the basis of the number of sialic acids, and their automatic and rapid identification without prior knowledge of protein glycosites or type and structure of the glycans. Copyright © 2016 Elsevier B.V. All rights reserved.
Liu, Ping; Fan, Sai; Wu, Guohua; Zhao, Rong; Liu, Wei; Zhao, Xudong
2016-05-01
A method for the simultaneous determination of 6 plant growth regulator (PGR) residues in bean sprout was developed by ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). 6-Benzylaminopurine, isopentennyladenine, 4-chlorophenoxyacetic acid, 4-fluorophenoxyacetic acid, indole-3- acetic acid and indole-3-butyric acid were concerned. Bean sprout samples were extracted by acetonitrile and QuEChERS extraction kit, purified by C18 powers. After centrifugation, the sample liquids was diluted 10 times by ultrapure water. The chromatographic analysis was carried out on an waters acquity UPLC BEH C18 column( 100 mm x 2.1 mm, 1.7 microm). The analyzer confirmed and quantified by mass spectrum of triple quadrupole in the multiple reaction monitoring (MRM) mode and quantified by matrix-matched external standard method. The calibration curves showed good linearity in each range with correlation coefficients greater than 0.998. 3 levels spiked recoveries were carried out using blank bean sprout extraction as substrate, the recoveries ranged from 84.2% to 107.5%, the relative standard deviations (RSDs) ranged from 3.08% to 12.71%. The qualitative limits of detections (S/N = 3) were 0.03-3.0 microg/kg and the quantitative limits(S/N = 10) were 0.1-10.0 microg/kg for the 6 PGRs. The method is simple and easy to operate, with less organic reagent, high sensitivity and good stability. It is suitable for the detection of 6 kinds of plant growth regulators in bean sprouts.
Kumar, Namala Durga Atchuta; Babu, K. Sudhakar; Gosada, Ullas; Sharma, Nitish
2012-01-01
Introduction: A selective, specific, and sensitive “Ultra High-Pressure Liquid Chromatography” (UPLC) method was developed for determination of candesartan cilexetil impurities as well asits degradent in tablet formulation. Materials and Methods: The chromatographic separation was performed on Waters Acquity UPLC system and BEH Shield RP18 column using gradient elution of mobile phase A and B. 0.01 M phosphate buffer adjusted pH 3.0 with Orthophosphoric acid was used as mobile phase A and 95% acetonitrile with 5% Milli Q Water was used as mobile phase B. Ultraviolet (UV) detection was performed at 254 nm and 210 nm, where (CDS-6), (CDS-5), (CDS-7), (Ethyl Candesartan), (Desethyl CCX), (N-Ethyl), (CCX-1), (1 N Ethyl Oxo CCX), (2 N Ethyl Oxo CCX), (2 N Ethyl) and any unknown impurity were monitored at 254 nm wavelength, and two process-related impurities, trityl alcohol and MTE impurity, were estimated at 210 nm. Candesartan cilexetil andimpurities were chromatographed with a total run time of 20 min. Results: Calibration showed that the response of impurity was a linear function of concentration over the range limit of quantification to 2 μg/mL (r2≥0.999) and the method was validated over this range for precision, intermediate precision, accuracy, linearity, and specificity. For the precision study, percentage relative standard deviation of each impurity was <15% (n=6). Conclusion: The method was found to be precise, accurate, linear, and specific. The proposed method was successfully employed for estimation of candesartan cilexetil impurities in pharmaceutical preparations. PMID:23781475
Bihan, Kevin; Sauzay, Chloé; Goldwirt, Lauriane; Charbonnier-Beaupel, Fanny; Hulot, Jean-Sebastien; Funck-Brentano, Christian; Zahr, Noël
2015-02-01
Vemurafenib (Zelboraf) is a new tyrosine kinase inhibitor that selectively targets activated BRAF V600E gene and is indicated for the treatment of advanced BRAF mutation-positive melanoma. We developed a simple method for vemurafenib quantification using liquid chromatography-tandem mass spectrometry. A stability study of vemurafenib in human plasma was also performed. (13)C(6)-vemurafenib was used as the internal standard. A single-step protein precipitation was used for plasma sample preparation. Chromatography was performed on an Acquity UPLC system (Waters) with chromatographic separation by the use of an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7-mm particle size; Waters). Quantification was performed using the monitoring of multiple reactions of following transitions: m/z 488.2 → 381.0 for vemurafenib and m/z 494.2 → 387.0 for internal standard. This method was linear over the range from 1.0 to 100.0 mcg/mL. The lower limit of quantification was 0.1 mcg/mL for vemurafenib in plasma. Vemurafenib remained stable for 1 month at all levels tested, when stored indifferently at room temperature (20 °C), at +4 °C, or at -20 °C. This method was used successfully to perform a plasma pharmacokinetic study of vemurafenib in a patient after oral administration at a steady state. This liquid chromatography-tandem mass spectrometry method for vemurafenib quantification in human plasma is simple, rapid, specific, sensitive, accurate, precise, and reliable.
Schuster, Georg; Lindner, Wolfgang
2011-06-01
Novel saccharide-based stationary phases were developed by applying non-enzymatic browning (Maillard Reaction) on aminopropyl silica material. During this process, the reducing sugars glucose, lactose, maltose, and cellobiose served as "ligand primers". The reaction cascade using cellobiose resulted in an efficient chromatographic material which further served as our model Chocolate HILIC column. (Chocolate refers to the fact that these phases are brownish.) In this way, an amine backbone was introduced to facilitate convenient manipulation of selectivity by additional attractive or repulsive ionic solute-ligand interactions in addition to the typical HILIC retention mechanism. In total, six different test sets and five different mobile phase compositions were investigated, allowing a comprehensive evaluation of the new polar column. It became evident that, besides the so-called HILIC retention mechanism based on partition phenomena, additional adsorption mechanisms, including ionic interactions, take place. Thus, the new column is another example of a HILIC-type column characterized by mixed-modal retention increments. The glucose-modified materials exhibited the relative highest overall hydrophobicity of all grafted Chocolate HILIC columns which enabled retention of lipophilic analytes with high water content mobile phases.
Headache in Behçet's syndrome: review of literature and NYU Behçet's syndrome center experience.
Vishwanath, Vijay; Wong, Ericka; Crystal, Sara C; Robbins, Matthew S; Filopoulos, Maria; Lipton, Richard B; Yazici, Yusuf; Kister, Ilya
2014-09-01
Headache, a common and disabling symptom in Behçet's syndrome, may be associated with a variety of neurologic syndromes and ocular inflammation, or may present as an isolated feature. Our objective is to describe the various neurologic and ocular syndromes of Behçet's syndrome of which headache is a symptom, and to review the features of isolated headaches in Behçet's. We also report results of a study of headache in Behçet's syndrome patients who are followed at NYU Hospital for Joint Diseases, the first study of its kind in North American patients, and the first to document prevalence of both episodic and chronic daily headache in Behçet's.
Mauko, Lea; Nordborg, Anna; Hutchinson, Joseph P; Lacher, Nathan A; Hilder, Emily F; Haddad, Paul R
2011-01-15
We present a new method for the analysis of glycans enzymatically released from monoclonal antibodies (MAbs) employing a zwitterionic-type hydrophilic interaction chromatography (ZIC-HILIC) column coupled with electrospray ionization mass spectrometry (ESI-MS). Both native and reduced glycans were analyzed, and the developed procedure was compared with a standard HILIC procedure used in the pharmaceutical industry whereby fluorescent-labeled glycans are analyzed using a TSK Amide-80 column coupled with fluorescence detection. The separation of isobaric alditol oligosaccharides present in monoclonal antibodies and ribonuclease B is demonstrated, and ZIC-HILIC is shown to have good capability for structural recognition. Glycan profiles obtained with the ZIC-HILIC column and ESI-MS provided detailed information on MAb glycosylation, including identification of some less abundant glycan species, and are consistent with the profiles generated with the standard procedure. This new ZIC-HILIC method offers a simpler and faster approach for glycosylation analysis of therapeutic antibodies. Copyright © 2010 Elsevier Inc. All rights reserved.
Jadhav, Sushant Bhimrao; Kumar, C Kiran; Bandichhor, Rakeshwar; Bhosale, P N
2016-01-25
A new UPLC-TOF/MS compatible, reverse phase-stability indicating method was developed for determination of Omeprazole (OMP) and its related substances in pharmaceutical dosage forms by implementing Design of Experiment (DoE) i.e. two level full factorial Design (2(3)+3 center points=11 experiments) to understand the Critical Method Parameters (CMP) and its relation with Critical Method Attribute (CMA); to ensure robustness of the method. The separation of eleven specified impurities including conversion product of OMP related compound F (13) and G (14) i.e. Impurity-I (1), OMP related compound-I (11) and OMP 4-chloro analog (12) was achieved in a single method on Acquity BEH shield RP18 100 × 2.1 mm, 1.7 μm column, with inlet filter (0.2 μm) using gradient elution and detector wavelength at 305 nm and validated in accordance with ICH guidelines and found to be accurate, precise, reproducible, robust and specific. The drug was found to degrade extensively in heat, humidity and acidic conditions and forms unknown degradation products during stability studies. The same method was used for LC-MS analysis to identify m/z and fragmentation of maximum unknown impurities (Non-Pharmacopoeial) i.e. Impurity-I (1), Impurity-III (3), Impurity-V (5) and Impurity-VIII (9) formed during stability studies. Based on the results, degradation pathway for the drug has been proposed and synthesis of identified impurities i.e. impurities (Impurity-I (1), Impurity-III (3), Impurity-V (5) and Impurity-VIII (9)) are discussed in detail to ensure in-depth understanding of OMP and its related impurities and optimum performance during lifetime of the product. Copyright © 2015. Published by Elsevier B.V.
Wang, Weicong; Zheng, Xin; Wang, Hanping; Wang, Lu; Jiang, Ji; Hu, Pei
2017-05-30
Avitinib (AC0010) is a mutant-selective epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKI), designed to be a targeted therapeutic agent for non-small cell lung cancer (NSCLC) patients harboring EGFR active and T790M resistant mutations. A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination of Avitinib and its five metabolites (M1, M2, M4, M7, MII-6) in human cerebrospinal fluid (CSF). The samples were purified by protein precipitation and separated on a BEH C 18 column (2.1×50mm, 1.7μm). Electrospray ionization (ESI) in positive ion mode and multiple reaction monitoring (MRM) were used to monitor the ion transitions at m/z 488/257, 474/403, 504/487, 434/377, 490/405, 476/391. The results indicated that the method had excellent sensitivity and specificity. The linear range covered from 0.05 to 50ng/mL for Avitinib, M1, M4, M7, and MII-6, and from 0.01 to 10ng/mL for M2. Intra-day and inter-day precisions (in terms of% RSD) were all <15% and the accuracies (in terms of% RE) were within the range of ±15%. The lower limit of quantification (LLOQ), matrix effect, extraction recovery, stability and dilution integrity were also validated and satisfied with the criteria of validation. Finally, the method was successfully applied to a blood-brain barrier (BBB) penetration rate research of NSCLC patients after an oral administration of Avitinib. Copyright © 2017. Published by Elsevier B.V.
Tang, Huaibo; Yan, Miao; Li, Huande; Xun, Tianrong; Deng, Yang; Zhao, Yeye; Deng, Long
2014-04-01
Semen Strychni, a known toxic drug in Chinese pharmacopoeia, is notable for its therapeutic effects on local muscle and joint pain. However, oral administration can be risky. Topically administered drugs accumulate in the topical muscles and knee joints without any major increase in plasma levels; only non-protein-bound drugs in the biological fluids of target tissues are effective for therapeutic effects. A sensitive and rapid ultra performance liquid chromatography - mass spectrometry (UPLC-MS) method coupled with a microdialysis technique was developed to determine the non-protein-bound strychnine (Str) and brucine (Bru) in rabbit muscle and synovial fluid microdialysate. The UPLC separation was carried out using a 1.7μm BEH C18 column (50 mm × 2.1 mm) with a mobile phase consisting of methanol: water (29.5:70.5, v/v) with 0.1% formic acid and 20 mM ammonium acetate in water. The method was validated at concentrations ranging from 0.58 ng/ml to 467.20 ng/ml for Str and from 0.42 ng/ml to 422.40 ng/ml for Bru. Intra-day and inter-day accuracy ranged from 99.1% to 103.2% for Str and from 95.8% to 108.8% for Bru with intra-day and inter-day precision within 9.7%. The proposed method was successfully applied to determine non-protein-bound Str and Bru, and the analysates concentration remained stable in rabbit muscle and synovial fluid after topical application of total Strychnos alkaloid patches, which indicated that total Strychnos alkaloid patches could substitute for the traditional oral administration of Semen Strychni. Copyright © 2013 John Wiley & Sons, Ltd.
Lu, Baiyi; Ren, Yiping; Huang, Baifen; Liao, Wenqun; Cai, Zengxuan; Tie, Xiaowei
2008-03-01
A novel ultra-performance liquid chromatography electrospray ionization tandem triple quadrupole mass spectrometry method for the simultaneous determination of four water-soluble vitamins, including vitamin B5 (VB5), vitamin B8 (VB8), vitamin B9 (VB9), and vitamin B12 (VB12) in fortified infant foods is developed and validated. A reverse phase UPLC separation system consisting of a Waters ACQUITY UPLC BEH C-18 column (2.1 mm x 100 mm i.d., 1.7 microm) and a binary gradient acetonitrile-water mobile phase is applied for the separation of the four water-soluble vitamins. Formic acid is spiked into the mobile phase to enhance the ionization efficiency. Tandem MS-MS analysis is performed in multi-reaction monitoring mode (MRM). Product-ion traces at m/z 220.1 --> 89.9 for VB5, 245.1 --> 227.1 for VB8, 442.3 --> 295.2 for VB9, and 678.9 --> 147.0 for VB12 are used for quantitation of the corresponding vitamins, and traces at m/z 455.5 --> 308.0 are used for methotrexate (internal standard). Limits of quantitation (LOQs) are 0.016, 0.090, 0.020, and 0.019 microg/L for VB5, VB8, VB9, and VB12, respectively. Intra- and inter-day precisions for the determination of the four vitamins are better than 6.84% and 12.26% in relative standard deviations, and recoveries for the four vitamins are in the range of 86.0~101.5%. The developed approach is applied for the determination of the trace amounts of the vitamins in fortified milk powers and fortified rice powers.
Fernández, P; González, M; Regenjo, M; Ares, A M; Fernández, A M; Lorenzo, R A; Carro, A M
2017-02-17
A miniaturized and simple method based on digitally programmed microextraction by packed sorbent (eVol ® -MEPS) coupled to ultra-performance liquid chromatography (UPLC) has been developed for quantitative determination of three synthetic cathinones and seven conventional drugs of abuse and metabolites. The influence of several extraction parameters, such as washing and elution solvents were tested. In addition important variables affecting MEPS performance, namely sample volume, sorbent drying time, washing solvent volume, elution volume, number of extraction cycles, sorbent phase and pH, were evaluated using an asymmetrical screening design. The optimal experimental conditions involved 300μL of plasma, loading 10×100μL of sample through a C8/SCX sorbent in a MEPS syringe placed in the semi-automatic eVol ® system, washing using 150μL H 2 O:MeOH (90:10, v/v), drying for 0.5min and elution using 200μL dichloromethane:2-propanol:ammonium hydroxide (78:20:2, v/v/v). The drugs separation was achieved using an ACQUITY BEH Shield RP18 column (2.1mm×100mm×1.7μm) in 3min. Under optimized conditions the proposed method was validated in terms of selectivity, linearity, limits of detection (LOD) and quantitation (LOQ), precision and matrix effect, using standard addition calibration. The combination of MEPS and UPLC provides a method for the primary screening of the analytes in 18min with excellent recoveries at three concentration levels, ranging between 80 and 104% (relative standard deviation <11%). The developed methodology has been successfully applied to plasma samples from polydrug abusers. Copyright © 2017 Elsevier B.V. All rights reserved.
Wu, Li-Lan; Wu, Yun-Shan; Chen, Wei-Ying; Zhou, Wen; Tang, Lipeng; Li, Ben; Liu, Bo
2017-07-15
Artemisitene shows a wide variety of pharmacological activities, such as antioxidant protection in vitro and in vivo. It has been identified as a novel Nrf2 inducer. However, there is no report on an ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method to quantitate artemisitene in rat plasma and its application to a pharmacokinetic profile study. An ACQUITY UPLC™ BEH Symmetry Shield RP18 column (1.7 μm, 2.1 mm × 100 mm) was used at a flow rate of 0.3 mL·min -1 . Mass detection was performed by electrospray ionization tandem mass spectrometry via multiple reaction monitoring (MRM) in positive mode. Plasma samples were pre-treated by a single-step extraction with 0.1% formic acid aqueous solutions-acetonitrile, and tolbutamide was used as internal standard. The calibration curve was from 0.98 to 1000 ng∙mL -1 (r 2 = 0.995). The extraction recoveries were 61.5-79.4% and 81.7-94.6% for artemisitene and tolbutamide, respectively. The lower limit of quantification (LLOQ) was 0.98 ng∙mL -1 . The absolute bioavailability of artemisitene was 3.7% after intravenous and oral administration in rats. The UPLC/MS/MS assay was validated for linearity, accuracy, stability, extraction recovery, matrix effects, and intra-day and inter-day precision. The method, for the first time, achieved some pharmacokinetic parameters and was successfully applied to a pharmacokinetic study Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Effect of aspirin on the pharmacokinetics and absorption of panax notoginseng saponins.
Tian, Zhihao; Pang, Huanhuan; Zhang, Qiang; Du, Shouying; Lu, Yang; Zhang, Lin; Bai, Jie; Li, Pengyue; Li, Danqi; Zhao, Mengdi; Chen, Xiaonan
2018-02-01
Panax notoginseng saponins, a traditional Chinese medicine extraction, and aspirin are both widely used to treat cerebral infarction in China. Good results in clinical practice have been achieved, when Panax notoginseng saponins was taken together with aspirin. To investigate the interaction of the two drugs in vivo, the concentration of notoginsenoside R 1 , ginsenoside Rg 1 , Rb 1 , Re and Rd. in blood were simultaneously measured by UPLC/MS/MS. Sample preparation was carried out by the protein precipitation technique with an internal standard saikosaponin A standard. The separation of six components was achieved by using an ACQUITY UPLC ®BEH C18 column (1.7μm 2.1×100mm) by gradient elution using water (containing 0.2% formic acid) and acetonitrile (containing 0.2% formic acid) as the mobile phase at a flow rate of 0.2mL/min. The pharmacokinetic parameters were determined using non-compartmental analysis. The transport of notoginsenoside R 1 , ginsenoside Rg 1 , Rb 1 , Re and Rd. in MDCK -MDR1 cell monolayer was also used to verify the conclusion of pharmacokinetic drug-drug interaction and study the mechanism of drug interaction. The concentrations of the five components increased in a certain extent when the two drugs administered together in rats. The values of apparent permeability coefficients were significantly increased when the two drugs were used together. Aspirin and salicylic acid could destroy the tight junction protein and open the intercellular space to increase the absorption of Panax notoginseng saponins. Pharmacokinetic drug-drug interaction in vivo existed between Panax notoginseng saponins and aspirin. The drug-drug interaction mainly occurred in the process of absorption. Copyright © 2018 Elsevier B.V. All rights reserved.
Severe panuveitis in neuro-Behçet's disease in Malaysia: a case series.
Othman, Khairuddin; Liza-Sharmini, Ahmad Tajudin; Ibrahim, Mohtar; Tharakan, John; Yanai, Ryoji; Zunaina, Embong
2017-01-01
Behçet's disease (BD) is a multisystemic disease that is very rare in Malaysia. About 5% of patients develop central nervous system involvement, termed neuro-Behçet's. Neuro-Behçet's is one of the most serious causes of long-term morbidity and mortality. We report two cases of neuro-Behçet's associated with uveitis (ocular BD) highlighting the clinical presentation, diagnostic measurement, and therapeutic management of these cases.
Sun, Ying; Jiang, Yi-Na; Xu, Chang-Fu; Du, Yun-Xia; Zhang, Jiao-Jiao; Yan, Yang; Gao, Xiao-Li
2014-02-01
Applying a model of bladder epithelial hyperplasia (BEH) caused by melamine-induced bladder calculus (BC), the recovery of BEH after melamine withdrawal was investigated. One experiment, comprising untreated, melamine and recovery groups, was conducted in Balb/c mice. Each group included 4 subgroups. Mice were fed normal-diet in untreated or a melamine-diet in other groups. The melamine-diet was then substituted with normal-diet in recovery group. Both of BC and BEH were observed after 14 and 56 days of melamine-diet. The BC is relatively uniform at the same melamine-diet durations. The BEH was diffuse with many mitotic figures, 4-7 rows of nuclei, and well-defined umbrella/intermediate cells. No marked differences in BEH degree were observed in the two different melamine-diet durations. On 4-42 days after melamine withdrawal, BC was not found, as the progressive regression with complete regression of BEH was observed, along with well-defined ageing/apoptotic cells in the superficial regions of BEH regression tissue. Conclusion, the melamine-induced BEH is relatively uniform, may be self-limiting in rows of nuclei, and can return to normal. Melamine withdrawal duration is critical for the BEH regression. Tissue of the BEH and its regression is ideal for exploring the renewal as well as growth biology of mammalian urothelium. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
[An aortic and femoral aneurysm revealing Behçet's disease].
Lyazidi, Y; Abissegue, Y; Chtata, H T; Taberkant, M
2015-12-01
Vascular involvement in Behçet's disease is rare, but may be inaugural in many cases. We report a case of Behçet's disease revealed by two pre-rupture aneurysms - a subrenal abdominal aortic aneurysm and a femoral aneurysm. This patient had only one of the International Study Group for Behçet's disease diagnostic criteria: pseudofolliculitis. Behçet's disease must be considered as a possible diagnosis in patients with unexplained inflammatory arteriopathy. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Murakami, Hiroya; Horiba, Ruri; Iwata, Tomoko; Miki, Yuta; Uno, Bunji; Sakai, Tadao; Kaneko, Kazuhiro; Ishihama, Yasushi; Teshima, Norio; Esaka, Yukihiro
2018-01-15
Acetaldehyde (AA), which is present in tobacco smoke, automobile exhaust gases and alcohol beverage, is a mutagen and carcinogen. AA reacts with 2'-deoxyguanosine (dG) in DNA to form N 2 -ethyl-dG (EtdG) and cyclic, 1, N 2 -propano-dG (CPrdG), which are considered to have a critical role in carcinogenesis induced by AA. In this study, we have developed a highly sensitive method for the quantitation of the two AA-derived DNA adducts by using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) in which hydrophilic interaction chromatography (HILIC) employing mobile phases of high organic solvent concentration was selected to improve the ionization efficiency in the ESI process. Fourteen times and 11 times larger peak areas for EtdG and CPrdG, respectively, in HILIC-ESI-MS/MS were obtained compared with those in reversed phase (RP)-LC-ESI-MS/MS. Furthermore, 6.9 times (for EtdG) and 2.4 times (for CPrdG) larger peak areas were also obtained as additional enhancement by varying additive compounds in the HILIC mobile phases from ammonium acetate to ammonium bicarbonate. In total, the enhancements in detected MS signal intensities by exchanging from the RP-LC system to the HILIC system are 97 times for EtdG and 26 times for CPrdG, respectively. Three commercially available HILIC columns with different polar functional groups were examined and sufficient separation between normal 2'-deoxynucleosides and the AA-derived DNA adducts was achieved by a carbamoyl-bonded HILIC column. Finally, we applied the established method to quantify EtdG and CPrdG in the damaged calf thymus DNA. Copyright © 2017 Elsevier B.V. All rights reserved.
Turrell, Elizabeth; Stobo, Lesley; Lacaze, Jean-Pierre; Piletsky, Sergey; Piletska, Elena
2008-01-01
The combination of hydrophilic interaction liquid chromatography (HILIC) and liquid chromatography/mass spectrometry (LC/MS) for the determination of paralytic shellfish poisoning (PSP) toxins has been proposed for use in routine monitoring of shellfish. In this study, methods for the detection of multiple PSP toxins [saxitoxin (STX), neosaxitoxin (NEO), decarbamoyl saxitoxin (dcSTX), decarbamoyl neosaxitoxin (dcNEO), gonyautoxins 1-5 (GTX1, GTX2, GTX3, GTX4, GTX5), decarbamoyl gonyautoxins (dcGTX2 and dcGTX3), and the N-sulfocarbamoyl C toxins (C1 and C2)] were optimized using single (MS) and triple quadrupole (MS/MS) instruments. Chromatographic separation of the toxins was achieved by using a TSK-gel Amide-80 analytical column, although superior chromatography was observed through application of a ZIC-HILIC column. Preparative procedures used to clean up shellfish extracts and concentrate PSP toxins prior to analysis were investigated. The capacity of computationally designed polymeric (CDP) materials and HILIC solid-phase extraction (SPE) cartridges to retain highly polar PSP toxins was explored. Three CDP materials and 2 HILIC cartridges were assessed for the extraction of PSP toxins from aqueous solution. Screening of the CDPs showed that all tested polymers adsorbed PSP toxins. A variety of elution procedures were examined, with dilute 0.01% acetic acid providing optimum recovery from a CDP based on 2-(trifluoromethyl)acrylic acid as the monomer. ZIC-HILIC SPE cartridges were superior to the PolyLC equivalent, with recoveries ranging from 70 to 112% (ZIC-HILIC) and 0 to 90% (PolyLC) depending on the PSP toxin. It is proposed that optimized SPE and HILIC-MS methods can be applied for the quantitative determination of PSP toxins in shellfish.
Ibrahim, Mohammed E A; Wahab, M Farooq; Lucy, Charles A
2014-04-11
Hydrophilic interaction liquid chromatography (HILIC) is a fast growing separation technique for hydrophilic and polar analytes. In this work, we combine the unique selectivity of carbon surfaces with the high efficiency of core-shell silica. First, 5 μm core-shell silica is electrostatically coated with 105 nm cationic latex bearing quaternary ammonium groups. Then 50 nm anionic carbon nanoparticles are anchored onto the surface of the latex coated core-shell silica particles to produce a hybrid carbon-silica phase. The hybrid phase shows different selectivity than ten previously classified HILIC column chemistries and 36 stationary phases. The hybrid HILIC phase has shape selectivity for positional isomeric pairs (phthalic/isophthalic and 1-naphthoic/2-naphthoic acids). Fast and high efficiency HILIC separations of biologically important carboxylates, phenols and pharmaceuticals are reported with efficiencies up to 85,000 plates m(-1). Reduced plate height of 1.9 (95,000 plates m(-1)) can be achieved. The hybrid phase is stable for at least 3 months of usage and storage under typical HILIC eluents. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhao, Heng-Qiang; Wang, Xiao; Li, Hong-Mei; Yang, Bin; Yang, Hong-Jun; Huang, Luqi
2013-08-15
A method combining hydrophilic interaction chromatography (HILIC) and electrospray ionization mass spectrometry (ESI-MS) was developed for the characterization and determination of natural Cordyceps. Separation was achieved on a Waters Xbridge Amide column with gradient elution. Identification of 15 target nucleosides and nucleobases was based on retention time, UV spectra and mass measurements of the protonated molecules ([M+H]⁺) and main fragment ions (ESI-TOF/MS). Eight non-target compounds were tentatively identified by ESI-TOF/MS. The 15 target compounds were quantified by HILIC-ESI-MS/MS using time-programmed selective ion monitoring or multiple reaction monitoring in positive-ion mode under optimized mass conditions. This technique showed good linearity, repeatability and recovery. This approach was also successfully implemented in the analysis of nucleosides and nucleobases in 12 batches of natural Cordyceps samples that were collected from different regions in China. The developed HILIC-ESI-MS method exhibited clear advantages in identifying and determining highly polar bioactive components in Cordyceps, as well as their quality control.
Behçet's syndrome patients exhibit specific microbiome signature.
Consolandi, Clarissa; Turroni, Silvia; Emmi, Giacomo; Severgnini, Marco; Fiori, Jessica; Peano, Clelia; Biagi, Elena; Grassi, Alessia; Rampelli, Simone; Silvestri, Elena; Centanni, Manuela; Cianchi, Fabio; Gotti, Roberto; Emmi, Lorenzo; Brigidi, Patrizia; Bizzaro, Nicola; De Bellis, Gianluca; Prisco, Domenico; Candela, Marco; D'Elios, Mario M
2015-04-01
Behçet syndrome is a systemic inflammatory condition characterized by muco-cutaneous and ocular manifestations, with central nervous system, vascular and/or gastro-intestinal involvement. The association of microbiota with Behçet syndrome has not been shown yet. Our work was aimed to compare the gut microbiota structure and the profiles of short-chain fatty acids production in Behçet syndrome patients and healthy control relatives. Here, we compared the fecal microbiota of 22 patients with Behçet syndrome and that of 16 healthy co-habiting controls, sharing the same diet and lifestyle by pyrosequencing of the V3-V4 hypervariable regions of the 16 rDNA gene and biochemical analyses. Our analyses showed significant differences in gut microbiota between Behçet patients and healthy cohabitants. In particular we found that Behçet's patients were significantly depleted in the genera Roseburia and Subdoligranulum. Roseburia showed a relative abundance value of 10.45±6.01% in healthy relatives and 4.97±5.09% in Behçet's patients, and Subdoligranulum, which reached a relative abundance of 3.28±2.20% in healthy controls, was only at 1.93±1.75% of abundance in Behçet's patients. Here we report, for the first time, that a peculiar dysbiosis of the gut microbiota is present in patients with Behçet syndrome and this corresponds to specific changes in microbiome profile. A significant decrease of butyrate production (P=0.0033) in Behçet's patients was demonstrated. Butyrate is able to promote differentiation of T-regulatory cells, and consequently the results obtained prompt us to speculate that a defect of butyrate production might lead to both reduced T-reg responses and activation of immuno-pathological T-effector responses. Altogether, our results indicate that both a peculiar dysbiosis of the gut microbiota and a significant decrease of butyrate production are present in patients with Behçet syndrome. Published by Elsevier B.V.
Shang, Tanya Q; Saati, Andrew; Toler, Kelly N; Mo, Jianming; Li, Heyi; Matlosz, Tonya; Lin, Xi; Schenk, Jennifer; Ng, Chee-Keng; Duffy, Toni; Porter, Thomas J; Rouse, Jason C
2014-07-01
A highly robust hydrophilic interaction liquid chromatography (HILIC) method that involves both fluorescence and mass spectrometric detection was developed for profiling and characterizing enzymatically released and 2-aminobenzamide (2-AB)-derivatized mAb N-glycans. Online HILIC/mass spectrometry (MS) with a quadrupole time-of-flight mass spectrometer provides accurate mass identifications of the separated, 2-AB-labeled N-glycans. The method features a high-resolution, low-shedding HILIC column with acetonitrile and water-based mobile phases containing trifluoroacetic acid (TFA) as a modifier. This column and solvent system ensures the combination of robust chromatographic performance and full compatibility and sensitivity with online MS in addition to the baseline separation of all typical mAb N-glycans. The use of TFA provided distinct advantages over conventional ammonium formate as a mobile phase additive, such as, optimal elution order for sialylated N-glycans, reproducible chromatographic profiles, and matching total ion current chromatograms, as well as minimal signal splitting, analyte adduction, and fragmentation during HILIC/MS, maximizing sensitivity for trace-level species. The robustness and selectivity of HILIC for N-glycan analyses allowed for method qualification. The method is suitable for bioprocess development activities, heightened characterization, and clinical drug substance release. Application of this HILIC/MS method to the detailed characterization of a marketed therapeutic mAb, Rituxan(®), is described. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Remoroza, C; Cord-Landwehr, S; Leijdekkers, A G M; Moerschbacher, B M; Schols, H A; Gruppen, H
2012-09-01
The combined action of endo-polygalacturonase (endo-PGII), pectin lyase (PL), pectin methyl esterase (fungal PME) and RG-I degrading enzymes enabled the extended degradation of methylesterified and acetylated sugar beet pectins (SBPs). The released oligomers were separated, identified and quantified using hydrophilic interaction liquid chromatography (HILIC) with online electrospray ionization ion trap mass spectrometry (ESI-IT-MS(n)) and evaporative light scattering detection (ELSD). By MS(n), the structures of galacturonic acid (GalA) oligomers having an acetyl group in the O-2 and/or O-3 positions eluting from the HILIC column were elucidated. The presence of methylesterified and/or acetylated galacturonic acid units within an oligomer reduced the interaction with the HILIC column significantly compared to the unsubstituted GalA oligomers. The HILIC column enables a good separation of most oligomers present in the digest. The use of ELSD to quantify oligogalacturonides was validated using pure GalA standards and the signal was found to be independent of the chemical structure of the oligomer being detected. The combination of chromatographic and enzymatic strategies enables to distinguish SBPs having different methylesters and acetyl group distribution. Copyright © 2012 Elsevier Ltd. All rights reserved.
Vass, Andrea; Robles-Molina, José; Pérez-Ortega, Patricia; Gilbert-López, Bienvenida; Dernovics, Mihaly; Molina-Díaz, Antonio; García-Reyes, Juan F
2016-07-01
The aim of the study was to evaluate the performance of different chromatographic approaches for the liquid chromatography/mass spectrometry (LC-MS(/MS)) determination of 24 highly polar pesticides. The studied compounds, which are in most cases unsuitable for conventional LC-MS(/MS) multiresidue methods were tested with nine different chromatographic conditions, including two different hydrophilic interaction liquid chromatography (HILIC) columns, two zwitterionic-type mixed-mode columns, three normal-phase columns operated in HILIC-mode (bare silica and two silica-based chemically bonded columns (cyano and amino)), and two standard reversed-phase C18 columns. Different sets of chromatographic parameters in positive (for 17 analytes) and negative ionization modes (for nine analytes) were examined. In order to compare the different approaches, a semi-quantitative classification was proposed, calculated as the percentage of an empirical performance value, which consisted of three main features: (i) capacity factor (k) to characterize analyte separation from the void, (ii) relative response factor, and (iii) peak shape based on analytes' peak width. While no single method was able to provide appropriate detection of all the 24 studied species in a single run, the best suited approach for the compounds ionized in positive mode was based on a UHPLC HILIC column with 1.8 μm particle size, providing appropriate results for 22 out of the 24 species tested. In contrast, the detection of glyphosate and aminomethylphosphonic acid could only be achieved with a zwitterionic-type mixed-mode column, which proved to be suitable only for the pesticides detected in negative ion mode. Finally, the selected approach (UHPLC HILIC) was found to be useful for the determination of multiple pesticides in oranges using HILIC-ESI-MS/MS, with limits of quantitation in the low microgram per kilogram in most cases. Graphical Abstract HILIC improves separation of multiclass polar pesticides.
Fu, Qing; Wang, Jun; Liang, Tu; Xu, Xiaoyong; Jin, Yu
2013-11-01
A systematic evaluation of retention behavior of carbohydrates in hydrophilic interaction liquid chromatography (HILIC) was performed. The influences of mobile phase, stationary phase and buffer salt on the retention of carbohydrates were investigated. According to the results, the retention time of carbohydrates decreased as the proportion of acetonitrile in mobile phase decreased. Increased time of carbohydrates was observed as the concentration of buffer salt in mobile phase increased. The retention behavior of carbohydrates was also affected by organic solvent and HILIC stationary phase. Furthermore, an appropriate retention equation was used in HILIC mode. The retention equation lnk = a + blnC(B) + cC(B) could quantitatively describe the retention factors of carbohydrates of plant origin with good accuracy: the relative error of the predicted time to actual time was less than 0.3%. The evaluation results could provide guidance for carbohydrates to optimize the experimental conditions in HILIC method development especially for carbohydrate separation
Qi, Chao; Cai, Qianqian; Zhao, Pan; Jia, Xiuna; Lu, Nan; He, Lu; Hou, Xiaohong
2016-06-03
Metal-organic framework MIL-101(Cr) was successfully used as an efficient sorbent in a vortex-assisted dispersive solid-phase extraction (VA-DSPE) and applied for the determination and the pharmacokinetic of imatinib mesylate in rat plasma by UPLC-MS/MS. In the enrichment of imatinib from rat plasma, the analyte was efficiently adsorbed on MIL-101(Cr) and simply recovered by using initial mobile phase (0.1% formic acid-methanol (6:4 v/v)) as elution solvent. Meanwhile, the protein in the plasma samples was excluded from the porous structure of MIL-101(Cr), leading to direct extraction of drug molecule from protein-rich biological samples without any other pretreatment procedure. After being removed, the supernatant was filtered and directly injected into the UPLC-MS/MS for the analysis of the target. The experimental parameters, including nature of MOFs, amount of MIL-101(Cr), pH value of aqueous solution, extraction time, type and volume of elution solvent, were systematically optimized. After VA-DSPE, chromatographic separation was performed on an ACQUITY UPLC(®) BEH C18 column (2.1mm×100mm, 1.7μm) with a 3min gradient elution using 0.1% formic acid and methanol as mobile phase at a flow rate of 0.3mL/min. The detection was accomplished on a tandem mass spectrometer via an electrospray ionization (ESI) source by multiple reaction monitoring (MRM) in the positive ionization mode. The lower limit of quantification of 1ng/mL was achieved and the mean recovery of the analyte was higher than 81.2%. Moreover, computational simulation was primarily applied to predict the adsorption behavior and revealed the molecular interactions and free binding energies between MIL-101(Cr) and imatinib with the molecular modeling method, providing certain explanation of the adsorption mechanism. The originally established pretreatment and detection method has some merits, such as less solvent consumption, easy operation, higher sensitivity and lower matrix effect. And the MIL-101(Cr) exhibited a potential as an efficient sorbent in the enrichment of the analyte from complex biosamples. Copyright © 2016 Elsevier B.V. All rights reserved.
Sugiura, Koichi; Min, Jun Zhe; Toyo'oka, Toshimasa; Inagaki, Shinsuke
2008-09-26
The rapid, sensitive and simultaneous determination of six polyamines, i.e., ornithine (ORN), 1,3-diaminopropane (DAP), putrescine (PUT), cadaverine (CAD), spermidine (SPD) and spermine (SPM), in human hairs was performed by ultra-performance liquid chromatography (UPLC) with fluorescence (FL) detection and electrospray-ionization time-of-flight mass spectrometry (ESI-TOF-MS). The primary (-NH(2)) and secondary (-NH) amines in the polyamine structures were first labeled with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) at 60 degrees C for 30 min in the mixture of 0.1M borax (pH 9.3) and acetonitrile (CH(3)CN). The resulting derivatives were perfectly separated using an ACQUITY UPLC BEH C(18) column (1.7 microm, 100 mm x 2.1mm i.d.) by a gradient elution with a mixture of water-acetonitrile containing 0.1% formic acid (HCOOH). The separated polyamine derivatives were sensitively detected with both FL and TOF-MS. The detection limits in FL and TOF-MS were 11-86 and 2-5 fmol, respectively. However, the determination of several polyamines by FL detection was interfered with by endogenous substances in the hair. Therefore, the simultaneous determination in hair was carried out by the combination of UPLC separation and the ESI-TOF-MS detection. The structures of the polyamines were identified from the protonated-molecular ions [M+H](+) obtained from the TOF-MS measurement. A good linearity was achieved from the calibration curves, that was obtained by plotting the peak area ratios of the analytes relative to the internal standard (IS), i.e., 1,6-diaminohexane (DAH), against the injected amounts of each polyamine (0.05-50 pmol, r(2)>0.999). The proposed method was applied to the determination in the hairs of healthy volunteers. The mean concentrations of ORN, DAP, PUT, CAD, SPD and SPM in 1mg of human hairs (n=20) were 1.46, 0.18, 1.18, 0.11, 1.97 and 0.98 pmol, respectively. Because the proposed method provides a good mass accuracy and the trace detection of the polyamines in hair, this analytical technique seems to be applicable for the determination of various biological compounds in hair.
Hearing loss in Behçet syndrome.
Bakhshaee, Mehdi; Mahdi, Bakhshaee; Ghasemi, Mohammad Mehdi; Mehdi, Ghasemi Mohammad; Hatef, Mohammad Reza; Reza, Hatef Mohammad; Talebmehr, Mahdieh; Mahdieh, Talebmehr; Shakeri, Mohammad Taghi; Taghi, Shakeri Mohammad
2007-09-01
To determine the prevalence and characteristics of hearing loss in Behçet syndrome. This study included 27 patients with Behçet syndrome and 35 sex-and age-matched controls. A complete audiological evaluation was performed. The average pure-tone audiograms from both groups showed a statistically significant hearing loss in the Behçet group. Sixteen patients (59.26%) showed some degrees of sensorineural hearing loss (SNHL), with the high-frequency type (4, 8, 10, and 12 kHz) being the most common pattern (93.75%). Hearing loss was the fourth most common manifestation. Although the patient's age, sex, and the duration of the disease were not related to hearing loss, there was a significant correlation between a negative pathergy test and hearing loss in patients with Behçet syndrome. We should consider audiovestibular involvement in Behçet syndrome as a common finding.
HILIC separation mechanisms of tetracyclines on amino bonded silica column
USDA-ARS?s Scientific Manuscript database
Effects of mobile phase variations on the chromatographic separation on amino bonded silica column in hydrophilic interaction chromatography (HILIC) were investigated for four zwitterionic tetracyclines (TCs): oxytetracycline, doxycycline, chlortetracycline and tetracycline. A mixed-mode retention m...
Hilliard, Mark; Alley, William R; McManus, Ciara A; Yu, Ying Qing; Hallinan, Sinead; Gebler, John; Rudd, Pauline M
Glycosylation is an important attribute of biopharmaceutical products to monitor from development through production. However, glycosylation analysis has traditionally been a time-consuming process with long sample preparation protocols and manual interpretation of the data. To address the challenges associated with glycan analysis, we developed a streamlined analytical solution that covers the entire process from sample preparation to data analysis. In this communication, we describe the complete analytical solution that begins with a simplified and fast N-linked glycan sample preparation protocol that can be completed in less than 1 hr. The sample preparation includes labelling with RapiFluor-MS tag to improve both fluorescence (FLR) and mass spectral (MS) sensitivities. Following HILIC-UPLC/FLR/MS analyses, the data are processed and a library search based on glucose units has been included to expedite the task of structural assignment. We then applied this total analytical solution to characterize the glycosylation of the NIST Reference Material mAb 8761. For this glycoprotein, we confidently identified 35 N-linked glycans and all three major classes, high mannose, complex, and hybrid, were present. The majority of the glycans were neutral and fucosylated; glycans featuring N-glycolylneuraminic acid and those with two galactoses connected via an α1,3-linkage were also identified.
Kubica, Paweł; Kot-Wasik, Agata; Wasik, Andrzej; Namieśnik, Jacek
2013-05-10
Two analytical procedures are proposed where HILIC and RPLC techniques are coupled with tandem mass spectrometry detection for rapid determination of trace amounts of nicotine in zero-level liquids for electronic cigarettes. Samples are prepared on the basis of the approach "dilute & shoot" which makes this important step quick and not complicated. The chromatographic separation was carried out on a Zorbax XDB column (RPLC method) and Ascentis Si column (HILIC mode). Within-run precisions (CVs) measured at three concentration levels were as follows: 0.73%, 0.98% and 1.44% for RPLC method and 1.39%, 1.44% and 0.57% (HILIC mode). Between-run CVs were as follows: 1.94%, 1.02% and 1.22% for RPLC mode and 1.49%, 1.20% and 1.22% for HILIC mode. The detection limits of RPLC and HILIC modes were 4.08 and 3.90 ng/mL respectively. The proposed procedures are rapid, not complicated, sensitive and are suitable for fast determination of trace amounts of nicotine in zero-level liquids for electronic cigarettes. Copyright © 2013 Elsevier B.V. All rights reserved.
Concurrent profiling of polar metabolites and lipids in human plasma using HILIC-FTMS
NASA Astrophysics Data System (ADS)
Cai, Xiaoming; Li, Ruibin
2016-11-01
Blood plasma is the most popularly used sample matrix for metabolite profiling studies, which aim to achieve global metabolite profiling and biomarker discovery. However, most of the current studies on plasma metabolite profiling focused on either the polar metabolites or lipids. In this study, a comprehensive analysis approach based on HILIC-FTMS was developed to concurrently examine polar metabolites and lipids. The HILIC-FTMS method was developed using mixed standards of polar metabolites and lipids, the separation efficiency of which is better in HILIC mode than in C5 and C18 reversed phase (RP) chromatography. This method exhibits good reproducibility in retention times (CVs < 3.43%) and high mass accuracy (<3.5 ppm). In addition, we found MeOH/ACN/Acetone (1:1:1, v/v/v) as extraction cocktail could achieve desirable gathering of demanded extracts from plasma samples. We further integrated the MeOH/ACN/Acetone extraction with the HILIC-FTMS method for metabolite profiling and smoking-related biomarker discovery in human plasma samples. Heavy smokers could be successfully distinguished from non smokers by univariate and multivariate statistical analysis of the profiling data, and 62 biomarkers for cigarette smoke were found. These results indicate that our concurrent analysis approach could be potentially used for clinical biomarker discovery, metabolite-based diagnosis, etc.
Assessment of altered lipid homeostasis by HILIC-ion mobility-mass spectrometry-based lipidomics[S
Hines, Kelly M.; Herron, Josi; Xu, Libin
2017-01-01
Ion mobility-mass spectrometry (IM-MS) has proven to be a highly informative technique for the characterization of lipids from cells and tissues. We report the combination of hydrophilic-interaction liquid chromatography (HILIC) with traveling-wave IM-MS (TWIM-MS) for comprehensive lipidomics analysis. Main lipid categories such as glycerolipids, sphingolipids, and glycerophospholipids are separated on the basis of their lipid backbones in the IM dimension, whereas subclasses of each category are mostly separated on the basis of their headgroups in the HILIC dimension, demonstrating the orthogonality of HILIC and IM separations. Using our previously established lipid calibrants for collision cross-section (CCS) measurements in TWIM, we measured over 250 CCS values covering 12 lipid classes in positive and negative modes. The coverage of the HILIC-IM-MS method is demonstrated in the analysis of Neuro2a neuroblastoma cells exposed to benzalkonium chlorides (BACs) with C10 or C16 alkyl chains, which we have previously shown to affect gene expression related to cholesterol and lipid homeostasis. We found that BAC exposure resulted in significant changes to several lipid classes, including glycerides, sphingomyelins, phosphatidylcholines, and phosphatidylethanolamines. Our results indicate that BAC exposure modifies lipid homeostasis in a manner that is dependent upon the length of the BAC alkyl chain. PMID:28167702
Kośliński, Piotr; Jarzemski, Piotr; Markuszewski, Michał J; Kaliszan, Roman
2014-03-01
Pterins are a class of potential cancer biomarkers. New methods involving hydrophilic interaction liquid chromatography (HILIC) and reversed phase (RP) high-performance liquid chromatography have been developed for analysis of eight pterin compounds: 6,7-dimethylpterin, pterin, 6-OH-methylpterin, biopterin, isoxanthopterin, neopterin, xanthopterin, and pterin-6-carboxylic acid. The effect of mobile phase composition, buffer type, pH and concentration on retention using HILIC, C8 and C18 RP stationary phases were examined. Separation of pterins on RP and HILIC stationary phase was performed and optimized. Eight pterins were successfully separated on HILIC Luna diol-bonded phases, Aquasil C18 RP column and LiChrospher C8 RP column. Determination and separation of the pterins from urine samples were performed on HILIC Luna and LiChrospher C8 RP columns which were chosen as the most appropriate ones. Finally, LiChrospher C8 RP column with fluorescence detection was selected for further validation of the method. The optimum chromatographic condition was mobile phase methanol (A)/phosphoric buffer pH 7, 10mM (B), isocratic elution 0-15min 5% A flow=0.5ml/min 15-17min. 5% A, flow=0.5-1ml/min the linearity (R(2)>0.997) and retention time repeatability (RSD%<1) were at satisfactory level. The precision of peak areas expressed as RSD in % was between 0.55 and 14. Pterins detection limits varied from 0.041ng/ml to 2.9ng/ml. Finally, HPLC method was used for the analysis of pterins in urine samples with two different oxidation procedures. Concentration levels of pterin compounds in bladder cancer patients and healthy subjects were compared. Copyright © 2013 Elsevier B.V. All rights reserved.
[Determination of aconitine, hypaconitine and mesaconitine in Shenfu injection].
Zhang, Pan-Pan; Zhang, Jun-Zhen; Wang, Zhao-Hong; Lu, Yong-Jiang; Jiang, Ye
2013-05-01
To establish a method for the content determination of indexes for measuring aconitic compounds contained in Shenfu injection, in order to provide basis for the evaluation of the curative effect of monkshood in Shenfu injection. The sample were purified and enriched with HF-LPME. ACQUITY UPLC BEH C18 column (2.1 mm x 50 mm, 1.7 microm) was adopted and eluted with a gradient program, with acetonitrile-10 mmol x L(-1) NH4HCO3 (pH 10) as the mobile phases. The flow rate was 0.45 mL x min(-1). The content was determined with ESI and MRM. The results showed that aconitine, hypaconitine and mesaconitine showed a good linear relationship, with r > 0.999, within the range of 0.1-100 ng x L(-1). The recoveries were detected to be 100.1%, 97.4%, 97.5%, with RSD being 1.2%, 1.1%, 1.5%, respectively. This method was used to prove the safety of Shenfu injection, and provide scientific basis for correct evaluation of curative effect of monkshood, as well as a reliable, simple and practical means for quality control of monkshood-containing Chinese materia medica preparations.
LC-MS/MS assay for the quantitation of the tyrosine kinase inhibitor neratinib in human plasma.
Kiesel, Brian F; Parise, Robert A; Wong, Alvin; Keyvanjah, Kiana; Jacobs, Samuel; Beumer, Jan H
2017-02-05
Neratinib is an orally available tyrosine kinase inhibitor targeting HER2 (ERBB2) and EGFR (ERBB). It is being clinically evaluated for the treatment of breast and other solid tumors types as a single agent or in combination with other chemotherapies. In support of several phase I/II clinical trials investigating neratinib combinations, we developed and validated a novel LC-MS/MS assay for the quantification of neratinib in 100μL of human plasma with a stable isotopic internal standard. Analytes were extracted from plasma using protein precipitation and evaporation of the resulting supernatant followed by resuspension. Chromatographic separation was achieved using an Acquity UPLC BEH Shield RP18 column and a gradient methanol-water mobile phase containing 10% ammonium acetate. An ABI 4000 mass spectrometer and electrospray positive mode ionization were used for detection. The assay was linear from 2 to 1,000ng/mL and proved to be accurate (98.9-106.5%) and precise (<6.2%CV), and met the FDA guidance for bioanalytical method validation. This LC-MS/MS assay will be an essential tool to further define the pharmacokinetics of neratinib. Copyright © 2016 Elsevier B.V. All rights reserved.
Baltusnikas, Juozas; Kilikevicius, Audrius; Venckunas, Tomas; Fokin, Andrej; Bünger, Lutz; Lionikas, Arimantas; Ratkevicius, Aivaras
2015-08-01
Myostatin dysfunction promotes muscle hypertrophy, which can complicate assessment of muscle properties. We examined force generating capacity and creatine kinase (CK) efflux from skeletal muscles of young mice before they reach adult body and muscle size. Isolated soleus (SOL) and extensor digitorum longus (EDL) muscles of Berlin high (BEH) mice with dysfunctional myostatin, i.e., homozygous for inactivating myostatin mutation, and with a wild-type myostatin (BEH+/+) were studied. The muscles of BEH mice showed faster (P < 0.01) twitch and tetanus contraction times compared with BEH+/+ mice, but only EDL displayed lower (P < 0.05) specific force. SOL and EDL of age-matched but not younger BEH mice showed greater exercise-induced CK efflux compared with BEH+/+ mice. In summary, myostatin dysfunction leads to impairment in muscle force generating capacity in EDL and increases susceptibility of SOL and EDL to protein loss after exercise.
Periat, Aurélie; Kohler, Isabelle; Thomas, Aurélien; Nicoli, Raul; Boccard, Julien; Veuthey, Jean-Luc; Schappler, Julie; Guillarme, Davy
2016-03-25
Reversed phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the gold standard technique in bioanalysis. However, hydrophilic interaction chromatography (HILIC) could represent a viable alternative to RPLC for the analysis of polar and/or ionizable compounds, as it often provides higher MS sensitivity and alternative selectivity. Nevertheless, this technique can be also prone to matrix effects (ME). ME are one of the major issues in quantitative LC-MS bioanalysis. To ensure acceptable method performance (i.e., trueness and precision), a careful evaluation and minimization of ME is required. In the present study, the incidence of ME in HILIC-MS/MS and RPLC-MS/MS was compared for plasma and urine samples using two representative sets of 38 pharmaceutical compounds and 40 doping agents, respectively. The optimal generic chromatographic conditions in terms of selectivity with respect to interfering compounds were established in both chromatographic modes by testing three different stationary phases in each mode with different mobile phase pH. A second step involved the assessment of ME in RPLC and HILIC under the best generic conditions, using the post-extraction addition method. Biological samples were prepared using two different sample pre-treatments, i.e., a non-selective sample clean-up procedure (protein precipitation and simple dilution for plasma and urine samples, respectively) and a selective sample preparation, i.e., solid phase extraction for both matrices. The non-selective pretreatments led to significantly less ME in RPLC vs. HILIC conditions regardless of the matrix. On the contrary, HILIC appeared as a valuable alternative to RPLC for plasma and urine samples treated by a selective sample preparation. Indeed, in the case of selective sample preparation, the compounds influenced by ME were different in HILIC and RPLC, and lower and similar ME occurrence was generally observed in RPLC vs. HILIC for urine and plasma samples, respectively. The complementary of both chromatographic modes was also demonstrated, as ME was observed only scarcely for urine and plasma samples when selecting the most appropriate chromatographic mode. Copyright © 2015 Elsevier B.V. All rights reserved.
Ethyl glucuronide: unusual distribution between head hair and pubic hair.
Kintz, Pascal; Villain, Marion; Vallet, Emilie; Etter, Mathieu; Salquebre, Guillaume; Cirimele, Vincent
2008-03-21
Ethyl glucuronide (EtG) is a minor metabolite of ethanol that can be detected in hair. In some specific situations, head hair can be missing, and therefore, alternative anatomical locations of hair are of interest. In this study, paired hair specimens (head hair and pubic hair) from eight social drinkers were analyzed for EtG. Each sample was decontaminated by two dichloromethane bathes (5 ml) for 2 min. After cutting into small pieces, about 50 mg of hair was incubated in 2 ml water in the presence of 10 ng of EtG-d5, used as internal standard and submitted to ultra-sonication for 2 h. The aqueous phase was extracted by SPE using Oasis MAX columns. The hair extract was separated on an ACQUITY BEH HILIC column using a gradient of acetonitrile and formate buffer. Detection was based on two daughter ions: transitions m/z 221-85 and 75 and m/z 226-75 for EtG and the IS, respectively. This laboratory is using a positive cut-off at 50 pg/mg. All eight head hair specimens were negative for EtG at a limit of quantitation fixed at 10 pg/mg. Surprisingly, EtG was identified at high concentrations in pubic hair, in the range 12-1370 pg/mg. It appears, therefore, that it is not possible to document the drinking status of a subject by simply switching from head hair to pubic hair.
Qiao, Lizhen; Li, Hua; Shan, Yuanhong; Wang, Shuangyuan; Shi, Xianzhe; Lu, Xin; Xu, Guowang
2014-02-21
In the present study, several geminal dicationic ionic liquids based on 1,4-bis(3-allylimidazolium)butane and 1,8-bis(3-allylimidazolium)octane in combination with different anions bromide and bis(trifluoromethanesulphonyl)imide were prepared and then bonded to the surface of 3-mercaptopropyl modified silica materials through the "thiol-ene" click chemistry as stationary phases for hydrophilic interaction chromatography (HILIC). Compared with their monocationic analogues, the dicationic ionic liquids stationary phases presented effective retention and good selectivity for typical hydrophilic compounds under HILIC mode with the column efficiency as high as 130,000 plates/m. Moreover, the influence of different alkyl chain spacer between dications and combined anions on the retention behavior and selectivity of the dicationic ionic liquids stationary phases under HILIC mode was displayed. The results indicated that the longer linkage chain would decrease the hydrophilicity and retention on the dicationic ionic liquid stationary phase, and while differently combined anions had no difference due to the exchangeability under the common HILIC mobile phase with buffer salt. Finally, the retention mechanism was investigated by evaluating the effect of chromatographic factors on retention, including the water content in the mobile phase, the mobile phase pH and buffer salt concentration. The results showed that the dicationic ionic liquids stationary phases presented a mixed-mode retention behavior with HILIC mechanism and anion exchange. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Ren-Qi; Bao, Kai; Croué, Jean-Philippe; Ng, Siu Choon
2013-11-21
Natural occurring organic compounds from food, natural organic matter, as well as metabolic products have received intense attention in current chemical and biological studies. Examination of unknown compounds in complex sample matrices is hampered by the limited choices for data readout and molecular elucidation. Herein, we report a generic method of hydrophilic interaction chromatography (HILIC) coupled with matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) for the rapid characterization of ingredients in pharmaceutical compounds, tea, and coffee. The analytes were first fractionated using a cationic HILIC column prior to MALDI-MS analyses. It was found that the retention times of a compound arising from different samples were consistent under the same conditions. Accordingly, molecules can be readily characterized by both the mass and chromatographic retention time. The retention behaviors of acidic and basic compounds on the cationic HILIC column were found to be significantly influenced by the pH of mobile phases, whereas neutral compounds depicted a constant retention time at different pH. The general HILIC-MALDI-MS method is feasible for fast screening of naturally occurring organic compounds. A series of homologs can be determined if they have the same retention behavior. Their structural features can be elucidated by considering their mass differences and hydrophilic properties as determined by HILIC chromatogram.
Horie, Kanta; Ikegami, Tohru; Hosoya, Ken; Saad, Nabil; Fiehn, Oliver; Tanaka, Nobuo
2007-09-14
Monolithic silica capillary columns for hydrophilic interaction liquid chromatography (HILIC) were prepared by on-column polymerization of acrylic acid on monolithic silica in a fused silica capillary modified with anchor groups. The products maintained the high permeability (K=5 x 10(-14)m(2)) and provided a plate height (H) of less than 10 microm at optimum linear velocity (u) and H below 20 microm at u=6mm/s for polar solutes including nucleosides and carbohydrates. The HILIC mode monolithic silica capillary column was able to produce 10000 theoretical plates (N) with column dead time (t(0)) of 20s at a pressure drop of 20 MPa or lower. The total performance was much higher than conventional particle-packed HILIC columns currently available. The gradient separations of peptides by a capillary LC-electrospray mass spectrometry system resulted in very different retention selectivity between reversed-phase mode separations and the HILIC mode separations with a peak capacity of ca. 100 in a 10 min gradient time in either mode. The high performance observed with the monolithic silica capillary column modified with poly(acrylic acid) suggests that the HILIC mode can be an alternative to the reversed-phase mode for a wide range of compounds, especially for those of high polarity in isocratic as well as gradient elution.
Structural Analysis of N- and O-glycans Using ZIC-HILIC/Dialysis Coupled to NMR Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qu, Yi; Feng, Ju; Deng, Shuang
2014-11-19
Protein glycosylation, an important and complex post-translational modification (PTM), is involved in various biological processes including the receptor-ligand and cell-cell interaction, and plays a crucial role in many biological functions. However, little is known about the glycan structures of important biological complex samples, and the conventional glycan enrichment strategy (i.e., size-exclusion column [SEC] separation,) prior to nuclear magnetic resonance (NMR) detection is time-consuming and tedious. In this study, we employed SEC, Zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC), and ZIC-HILIC coupled with dialysis strategies to enrich the glycopeptides from the pronase E digests of RNase B, followed by NMR analysis ofmore » the glycoconjugate. Our results suggest that the ZIC-HILIC enrichment coupled with dialysis is the most efficient, which was thus applied to the analysis of biological complex sample, the pronase E digest of the secreted proteins from the fungi Aspergillus niger. The NMR spectra revealed that the secreted proteins from A. niger contain both N-linked glycans with a high-mannose core and O-linked glycans bearing mannose and glucose with 1->3 and 1->6 linkages. In all, our study provides compelling evidence that ZIC-HILIC separation coupled to dialysis is superior to the commonly used SEC separation to prepare glycopeptides for the downstream NMR analysis, which could greatly facilitate the future NMR-based glycoproteomics research.« less
Colon perforation and Budd-Chiari syndrome in Behçet's disease.
Baş, Yılmaz; Güney, Güven; Uzbay, Pınar; Zobacı, Ethem; Ardalı, Selin; Özkan, Ayşegül Taylan
2015-05-02
Behçet's disease is a chronic inflammatory disease involving multiple systems, with vasculitis being the most important pathological feature. Multiple colon perforations are thought to be secondary to vasculitis and they occur in patients with ulcers. These may be encountered within the entire colon but most commonly in the ileocecal region. Intestinal perforation and Budd-Chiari syndrome are infrequent in Behçet's disease, and are associated with high mortality and morbidity. Budd-Chiari syndrome results from occlusion of either hepatic veins or adjacent inferior vena cava, or both. We report a patient with Behçet's disease having multiple perforations in the transverse colon, descending colon, and sigmoid colon. The patient also had Budd-Chiari syndrome due to inferior vena cava thrombosis extending into the right and middle hepatic vein. Our observations are presented with a review of the literature. In Behçet's disease, treatment of colon perforation necessitates urgent surgery, whereas management of Budd-Chiari syndrome is directed towards the underlying cause. Behçet's disease, as a chronic multisystemic disease with various forms of vasculitis, is resistant to medical and surgical treatment. Prognosis is worse in Behçet's disease with colon perforation than that in Budd-Chiari syndrome alone.
[Pathophysiology and new treatment of uveitis].
Yanai, Ryoji; Takeda, Atsunobu; Yoshimura, Takeru; Sonoda, Koh-Hei
2014-01-01
Uveitis is narrow-defined inflammation of the uvea, also clinically include all inflammatory conditions in the eye. Uveitis may occur as a consequence of various causes and background, such as autoimmune diseases, infections, and hematopoietic malignancy. We have to treat uveitis not only controlling the inflammation but also maintaining up the visual function of the eye because the most uveitis is chronic and relapsing inflammatory disorder. Behçét's disease is a systemic disease and results in loss of vision without adequate treatment. Behçét's disease was a representative of vision loss uveitis because Behçét's patient usually had treatment resistance of conventional treatment, such as colchicine and cyclosporine. However, biological therapy with TNF-α, which started from 2007, has revolutionized the treatment strategy of Behçét's disease. It is not too much to say that Behçét's patient is free from fear of vision loss by the dramatic decrease of ocular attach. Biological therapy is not approved as a treatment of uveitis except Behçét's disease. Some protracted cases of Sarcoidosis and Vogt-Koyanagi-Harada disease are resistant to corticosteroid therapy and require new treatment. In this review, we discuss the pathophysiology of uveitis and report new treatment of Behçét's disease by biological therapy.
Yu, Mingming; Hassan, Hazem E; Ibrahim, Ahmed; Bauer, Kenneth S; Kelly, Deanna L; Wang, Jia Bei
2014-08-15
Currently, there are no FDA approved medications for treatment of cocaine addiction underscoring the dire need to develop such a product. There is an accumulating body of evidence that l-tetrahydropalmatine (l-THP), a non-selective dopamine antagonist, can be used for the treatment of cocaine addiction. Indeed, the FDA recently approved its usage in a Phase I study in cocaine abusers and it was indispensable to develop a simple and sensitive method for the simultaneous determination of l-THP and cocaine in human plasma. We developed a UPLC-FLD method for quantitation of these molecules using an ACQUITY BEH C18 column (2.1 mm × 50mm, 1.7 μm) and a mobile phase that consisted of 10mM ammonium phosphate (pH=4.75), methanol, and acetonitrile (v:v:v, 78:16:6). Venlafaxine was used as the internal standard while hexane was used for the liquid-liquid extraction. The flow rate was 0.4 mL/min with fluorescence detection using an excitation wavelength of 230 nm and emission detection wavelength of 315 nm. This method was selective, linear and sensitive with a lower limit of quantification of 2.5 ng/mL for both cocaine and l-THP. The intra-day precision of cocaine and l-THP was <9.50% while the accuracy was <4.29%. The inter-day precision of cocaine and l-THP was <9.14%, and the accuracy was <12.49%. The recovery for cocaine and l-THP ranged from 43.95 to 50.02% and 54.65 to 58.31%, respectively. In comparison to forty reported cocaine quantitation methods this method is simple, sensitive and cost-effective and can be used for simultaneous quantitation of l-THP and cocaine. This method meets the FDA guidelines and can be used in current and future clinical studies. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhao, Yu; Zhao, Min; Jiang, Qi; Qin, Feng; Wang, Chengying; Xiong, Zhili; Wang, Shaojie; He, Zhonggui; Guo, Xingjie; Zhao, Longshan
2018-06-02
MP3950 is being developed as a gastroprokinetic candidate compound. To illustrate the pharmacokinetic profiles, absolute bioavailability after intravenous administration and oral administration with MP3950 as well as tissue distribution in vivo, an UPLC-MS/MS approach which was rapid and selective was developed to determine MP3950 in plasma and tissue of rat. Sample pre-treatment of plasma sample was one-step protein precipitation. 0.1% formic acid containing 5 mmol/L ammonium acetate-methanol(55/45,v/v) was used for isocratic elution on a Waters ACQUITY UPLC® BEH C18 (50 mm × 2.1 mm, 1.7 μm) to achieve the separation. The analysis was performed in MRM mode via positive ESI mode. LLOQ of the method was 10 ng/mL, and the linearity up to 10,000 ng/mL. The intra-day precision (relative standard deviation, RSD) was 4.0-9.0% and the inter-day precision was 4.2-10.6%. The accuracy (relative error, RE) was -1.2-2.4%. Tissue samples were collected from the brain, heart, liver, spleen, lung, kidney, stomach, duodenum, small intestine, large intestine, appendix and skeletal muscle. The same liquid chromatographic and mass spectrometric conditions were used, and it's proven that this method was feasible to analyze the MP3950 in tissues with good precision and accuracy over the range from 10 to 5000 ng·mL -1 . It was found that the concentration of MP3950 is higher in digestive system. The tissue distribution, pharmacokinetic and bioavailability of MP3950 in rats were carried out by the method for the first time, which can provide enough information for the further development and investigation of MP3950. Copyright © 2018. Published by Elsevier B.V.
Dong, Song-Tao; Niu, Hui-Min; Wu, Yin; Jiang, Jia-Lei; Li, Ying; Jiang, Kun-Yu; Wang, Xin; Zhang, Mao-Fan; Han, Ming-Feng; Meng, Sheng-Nan
2018-05-20
Canagliflozin is a novel, orally selective inhibitor of sodium-dependent glucose co-transporter-2 (SGLT2) for the treatment of patients with type 2 diabetes mellitus. In this study, a sensitive and efficient UPLC-MS/MS method for the quantification of canagliflozin and its metabolites in rat plasma was established and applied to pharmacokinetics in a type 2 diabetic rat model. We firstly investigated the pharmacokinetic changes of canagliflozin and its metabolites in type 2 diabetic rats in order to use canagliflozin more safely, reasonably and effectively. We identified three types of O-glucuronide metabolites (M5, M7 and M17), two kinds of oxidation metabolites (M8 and M9) and one oxidation and glucuronide metabolite (M16) using API 5600 triple-TOF-MS/MS. Following liquid⁻liquid extraction by tert-butyl methyl ether, chromatographic separation of canagliflozin and its metabolites were performed on a Waters XBridge BEH C18 column (100 × 2.1 mm, 2.5 μm) using 0.1% acetonitrile⁻formic acid (75:15, v / v ) as the mobile phase at a flow rate of 0.7 mL/min. Selected ion monitoring transitions of m / z 462.00→191.10, 451.20→153.10, 638.10→191.10 and 478.00→267.00 were chosen to quantify canagliflozin, empagliflozin (IS), O-glucuronide metabolites (M5, M7 and M17), and oxidation metabolites (M9) using an API 5500-triple-MS/MS in the positive electrospray ionization mode. The validation of the method was found to be of sufficient specificity, accuracy and precision. The pathological condition of diabetes could result in altered pharmacokinetic behaviors of canagliflozin and its metabolites. The pharmacokinetic parameters (AUC 0⁻t , AUC 0⁻∞ , CL z /F, and V z /F) of canagliflozin were significantly different between the CTRL and DM group rats ( p < 0.05 or p < 0.01), which may subsequently cause different therapeutic effects.
Kumar, Manoj; Sharma, Gaurav; Singla, Dinesh; Singh, Sukhjeet; Sahwney, Sudhir; Chauhan, Anurag S; Singh, Gagandeep; Kaur, Indu Pal
2014-03-01
A sensitive ultra-performance liquid chromatography (UPLC) method was developed for simultaneous estimation of all-trans retinoic acid (ATRA) and cholecalciferol (vitamin D3) in rat plasma. The method was validated over the linear range of 1.0-5000ng/ml (r(2)=0.999) for both vitamins with a limit of detection of 0.5ng/ml. Chromatographic separation was achieved using liquid-liquid extraction (LLE) on an Acquity BEH RP 18 column (2.1mm×50mm, I.D. 1.7μm), with mobile phase comprising of acetonitrile:methanol:water (90:8:2, v/v/v), at a flow rate of 0.20ml/min and a total run time of 5min. Intra and inter-day variability (RSD) was ≤3.1%, and the accuracy varied between 95.4-99.9% and 95.3-101.1% respectively, for ATRA and 98.5-100.8% and 99.3-101.7%, respectively for vitamin D3. High recovery of ≥96.0% for ATRA and ≥87.80% for vitamin D3 was achieved. ATRA and vitamin D3 were stable in plasma under different storage and processing conditions. The method was applied to estimate the total drug content and entrapment efficiency of ATRA and vitamin D3 loaded solid lipid nanoparticles (SLNs). Concentration of these two agents was determined in rat plasma after simultaneous subcutaneous administration in free form or when loaded into SLNs thus establishing pharmacokinetic application of the developed procedure. Results indicated an improvement in AUC0-∞ by 5.4 times and 29.4 times for ATRA and vitamin D3, respectively, upon their incorporation into SLNs. Simultaneous administration of these two vitamins and their improved and prolonged bioavailability has scope for their use in treatment and control of tuberculosis. Copyright © 2014 Elsevier B.V. All rights reserved.
Seroprevalence of Borrelia burgdorferi in patients with Behçet's disease.
Onen, Fatos; Tuncer, Dilek; Akar, Servet; Birlik, Merih; Akkoc, Nurullah
2003-11-01
Turkey is one of the countries where Behçet's disease is most prevalent. Although its pathogenesis is not defined clearly, infectious agents are thought to play a role in the etiology. In one study of a group of uveitis patients, including those with Behçet's disease, increased seropositivity to B. burgdorferi was reported by enzyme-linked immunosorbent assay (ELISA). The seroprevalence of B. burgdorferi has been found to be as high as 36% in some rural areas of Turkey, although Lyme disease caused by B. burgdorferi is quite rare. In this study, we investigated the seroreactivity to B. burgdorferi antigens in patients with Behçet's disease and compared it with that of healthy and disease controls. This study was conducted in Izmir in western Turkey. B. burgdorferi immunoglobulin (Ig)M and IgG antibodies were tested by ELISA in the sera of patients with Behçet's disease ( n=30), rheumatoid arthritis patients as disease controls ( n=31), and healthy controls ( n=31). Positive results were confirmed by Western blotting. The difference in B. burgdorferi seropositivity between the groups was not significant by any method. Seroreactivity to B. burgdorferi antigens by ELISA was detected in 26.7% of the patients with Behçet's disease, 35.5% of those with rheumatoid arthritis, and 19.4% of the healthy controls. Immunoblots were positive in 13.3% of the Behçet's disease patients, 22.6% of the rheumatoid arthritis patients, and 12.9% of healthy controls. These results suggest no association between Behçet's disease and B. burgdorferi infection.
Differential diagnosis and management of Behçet syndrome.
Ambrose, Nicola L; Haskard, Dorian O
2013-02-01
Behçet syndrome (also known as Behçet disease) is a rare condition that is associated with considerable morbidity. Cases of Behçet syndrome have been reported worldwide, but the highest prevalence occurs in countries that border the ancient Silk Route, such as Turkey and Iran. Although oral ulceration, genital ulceration and eye disease are the classic triad of manifestations, the cardiovascular, gastrointestinal, musculoskeletal and central nervous systems can also be affected. The syndrome is chronic and relapsing with some patients having benign episodes whereas others have more serious complications, including blindness or the rupture of a pulmonary arterial aneurysm. Diagnosing Behçet syndrome, particularly outside of endemic regions, often incurs a considerable delay owing to the rarity of this condition. Furthermore, a paucity exists of data from randomized controlled trials on the optimal therapeutic approaches to use in patients, as well as a lack of informative laboratory surrogate markers to monitor disease progression. This Review discusses the issues surrounding the diagnosis and differential diagnosis of Behçet syndrome and presents the current approaches to managing patients with this complex group of disorders.
Wilson, Paul; Larminie, Christopher; Smith, Rona
2016-01-01
To use literature mining to catalogue Behçet's associated genes, and advanced computational methods to improve the understanding of the pathways and signalling mechanisms that lead to the typical clinical characteristics of Behçet's patients. To extend this technique to identify potential treatment targets for further experimental validation. Text mining methods combined with gene enrichment tools, pathway analysis and causal analysis algorithms. This approach identified 247 human genes associated with Behçet's disease and the resulting disease map, comprising 644 nodes and 19220 edges, captured important details of the relationships between these genes and their associated pathways, as described in diverse data repositories. Pathway analysis has identified how Behçet's associated genes are likely to participate in innate and adaptive immune responses. Causal analysis algorithms have identified a number of potential therapeutic strategies for further investigation. Computational methods have captured pertinent features of the prominent disease characteristics presented in Behçet's disease and have highlighted NOD2, ICOS and IL18 signalling as potential therapeutic strategies.
Oğuz, Ali Kemal; Yılmaz, Seda; Akar, Nejat; Özdağ, Hilal; Gürler, Aysel; Ateş, Aşkın; Oygür, Çağdaş Şahap; Kılıçoğlu, Sibel Serin; Demirtaş, Selda
2015-08-01
C-type lectin domain family 12, member A (CLEC12A) is a C-type lectin-like pattern recognition receptor capable of recognizing monosodium urate crystals. Monosodium urate crystals, the causative agents of gout are also among the danger-associated molecular patterns reflecting cellular injury/cell death. In response to monosodium urate crystals, CLEC12A effectively inhibits granulocyte and monocyte/macrophage functions and hence acts as a negative regulator of inflammation. Behçet's syndrome and gout are autoinflammatory disorders sharing certain pathological (neutrophilic inflammation), clinical (exaggerated response to monosodium urate crystals) and therapeutic (colchicine) features. We propose the hypothesis that decreased expression of CLEC12A is a common denominator in the hyperinflammatory responses observed in Behçet's syndrome and gout. Major lines of evidence supporting this hypothesis are: (1) Downregulation/deficiency of CLEC12A is associated with hyperinflammatory responses. (2) CLEC12A polymorphisms with functional and clinical implications have been documented in other inflammatory diseases. (3) Colchicine, a fundamental therapeutic agent used both in Behçet's syndrome and gout is shown to oppose the downregulation of CLEC12A. (4) Behçet's syndrome and gout are characterized by a hyperinflammatory response to monosodium urate crystals and other than gout, Behçet's syndrome is the only inflammatory condition exhibiting this exaggerated response. (5) Genomewide linkage and association studies of Behçet's syndrome collectively point to 12p12-13, the chromosomal region harboring CLEC12A. (6) Patients with severe forms of Behçet's syndrome underexpress CLEC12A with respect to patients with mild forms of the disease. If supported by well-designed, rigorous experiments, the forementioned hypothesis pertinent to CLEC12A will carry important implications for therapy, designing experimental models, and uncovering immunopathogenic mechanisms in Behçet's syndrome and gout. Copyright © 2015 Elsevier Ltd. All rights reserved.
Behçet's disease with endocarditis and the Budd-Chiari syndrome.
McDonald, G S; Gad-Al-Rab, J
1980-01-01
Endocarditis of the mitral and aortic valves is described for the first time in a patient with Behçet's disease. A second patient had minor changes in the mitral valve similar to that seen in the vasculitis which occurs in this condition. Valvulitis in Behçet's disease probably has the same pathogenesis as the vasculitis. The second patient also had a rare combination of Behçet's disease and the Budd-Chiari syndrome, and the necropsy findings are described. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 PMID:7430372
Study on behaviors and performances of universal N-glycopeptide enrichment methods.
Xue, Yu; Xie, Juanjuan; Fang, Pan; Yao, Jun; Yan, Guoquan; Shen, Huali; Yang, Pengyuan
2018-04-16
Glycosylation is a crucial process in protein biosynthesis. However, the analysis of glycopeptides through MS remains challenging due to the microheterogeneity and macroheterogeneity of the glycoprotein. Selective enrichment of glycopeptides from complex samples prior to MS analysis is essential for successful glycoproteome research. In this work, we systematically investigated the behaviors and performances of boronic acid chemistry, ZIC-HILIC, and PGC of glycopeptide enrichment to promote understanding of these methods. We also optimized boronic acid chemistry and ZIC-HILIC enrichment methods and applied them to enrich glycopeptides from mouse liver. The intact N-glycopeptides were interpreted using the in-house analysis software pGlyco 2.0. We found that boronic acid chemistry in this study preferred to capture glycopeptides with high mannose glycans, ZIC-HILIC enriched most N-glycopeptides and did not show significant preference during enrichment and PGC was not suitable for separating glycopeptides with a long amino acid sequence. We performed a detailed study on the behaviors and performances of boronic acid chemistry, ZIC-HILIC, and PGC enrichment methods and provide a better understanding of enrichment methods for further glycoproteomics research.
Leijdekkers, A G M; Sanders, M G; Schols, H A; Gruppen, H
2011-12-23
Analysis of complex mixtures of plant cell wall derived oligosaccharides is still challenging and multiple analytical techniques are often required for separation and characterization of these mixtures. In this work it is demonstrated that hydrophilic interaction chromatography coupled with evaporative light scattering and mass spectrometry detection (HILIC-ELSD-MS(n)) is a valuable tool for identification of a wide range of neutral and acidic cell wall derived oligosaccharides. The separation potential for acidic oligosaccharides observed with HILIC is much better compared to other existing techniques, like capillary electrophoresis, reversed phase and porous-graphitized carbon chromatography. Important structural information, such as presence of methyl esters and acetyl groups, is retained during analysis. Separation of acidic oligosaccharides with equal charge yet with different degrees of polymerization can be obtained. The efficient coupling of HILIC with ELSD and MS(n)-detection enables characterization and quantification of many different oligosaccharide structures present in complex mixtures. This makes HILIC-ELSD-MS(n) a versatile and powerful additional technique in plant cell wall analysis. Copyright © 2011 Elsevier B.V. All rights reserved.
Jovanović, Marko; Stojanović, Biljana Jančić
2013-08-02
In this paper detailed analysis of a mixture of four amides (tropicamide, nicotinamide, tiracetam, and piracetam) and six sulfonamides (sulfanilamide, sulfacetamide, sulfamethoxazole, sulfafurazole, furosemide, and bumetanide) on aminopropyl column in hydrophilic interaction chromatography (HILIC) was carried out. Since, there are no papers on the topic of the assessment of the contribution of ion-exchange retention mechanism involved in the separation of the acidic compounds on aminopropyl column in HILIC mode, the authors utilized the retention data of the acidic sulfonamides for this purpose. Next, broad range of the aqueous buffer concentrations in the mobile phase was examined providing the separation under either HILIC or RP conditions. Turning points between these two mechanisms were determined and then the fitting of the experimental data in the localized and non-localized adsorption models in both RP and HILIC regions was assessed. Since not many papers in the literature were dealing with the estimation of factor influence on the retention behavior of neutral and acidic compounds on aminopropyl column in HILIC, Box-Behnken design and Response Surface Methodology were applied. On the basis of the obtained data, ten quadratic models were proposed and their adequacy was confirmed using ANOVA test. Furthermore, retention data was graphically evaluated by the construction of 3D response surface plots. Finally, good predictive ability of the suggested models was proved with five additional verification experiments. Copyright © 2013 Elsevier B.V. All rights reserved.
Wang, Fei; Yang, Fan; Tian, Yang; Liu, Jiawei; Shen, Jiwei; Bai, Quan
2018-01-01
A stoichiometric displacement model for retention (SDM-R) of small solutes and proteins based on hydrophilic interaction chromatography (HILIC) was presented. A linear equation that related the logarithm of the capacity factor of the solute to the logarithm of the concentration of water in the mobile phase was derived. The stoichiometric displacement parameters, Z (the number of water molecules required to displace a solute from ligands) and lgI (containing a number of constants that relate to the affinity of solute to the ligands) could be obtained from the slope and the intercept of the linear plots of lgk' vs. lg[H 2 O]. The retention behaviors and retention mechanism of 15 kinds of small solutes and 6 kinds of proteins on 5 kinds HILIC columns with different ligands were investigated with SDM-R in typical range of water concentration in mobile phase. A good linear relationship between lgk' and lg[H 2 O] demonstrated that the most rational retention mechanism of solute in HILIC was a stoichiometric displacement process between solute and solvent molecules with water as displacing agents, which was not only valid for small solutes, but also could be used to explain the retention mechanism of biopolymers in HILIC. Comparing with the partition and adsorption models in HILIC, SDM-R was superior to them. Copyright © 2017 Elsevier B.V. All rights reserved.
Liu, Hui-Miao; Dong, Ci; Zhang, Yong-Zhi; Tian, Ya-Yun; Chen, Hong-Xu; Zhang, Sai; Li, Na; Gu, Ping
2017-10-01
To investigate the clinical and MRI characteristics of spinal cord nerve Behçet's disease. One patient with spinal cord nerve Behçet's disease was admitted to our hospital at October 20, 2015. Spinal cord nerve Behçet's disease. Retrospective analysis was performed on such case as well as 16 cases of spinal cord nerve Behçet's disease reported in China or abroad. Seventeen cases of spinal cord type of neuro Behçet's disease include 13 men and 4 women, with an average age of onset of 34.8 years old. The mean time from Behçet's disease symptoms to spinal cord involvement were 10.8 years. The initial symptom in one case was spinal cord injury, and another 4 cases had a recurrence course. The most common performance of spinal cord injury was sensory disturbance (82.4%), following by weakness (76.5%), sphincter or sexual dysfunction (58.8%), and pain in back, backside of neck or lower chest (29.4%). The number of cells was slightly increased or the protein level was increased in cerebrospinal fluid test. And the water channel protein antibody and oligoclonal band of serum levels were all negative. The spinal cord injury involved more than 3 vertebral bodies in 10 cases, and involved more than half of spinal cord in sagittal plane in 8 cases. In acute stage, shock therapy with large dose of glucocorticoid was generally applied both in China and abroad. The clinical features of spinal cord nerve Behçet's disease were various, making it easily misdiagnosed. Longitudinal extensive transverse myelitis performs as a characteristic manifestation.
Analysis of illegal peptide drugs via HILIC-DAD-MS.
Janvier, Steven; De Sutter, Evelien; Wynendaele, Evelien; De Spiegeleer, Bart; Vanhee, Celine; Deconinck, Eric
2017-11-01
Biopharmaceuticals have established themselves as highly efficient medicines, and are still one of the fastest growing parts of the health-product industry. Unfortunately, the introduction of these promising new drugs went hand in hand with the creation of a black market for illegal and counterfeit biotechnology drugs. Particularly popular are the lyophilised peptides with a molecular weight of less than 5kDa. Most of them are meant for subcutaneous injection and are easily accessible via the internet. In recent years, different methods based on reversed phase liquid chromatography have been developed to detect and quantify these peptides. The emerging of more polar peptides however requires the introduction of other separation techniques. Therefore, we set out to develop and validate an analytical method based on hydrophilic interaction liquid chromatography (HILIC) to identify and quantify the most frequently encountered illegal peptides on the European market. For this objective, five different HILIC columns were selected and screened for their chromatographic performance. Among those columns, the ZIC HILIC column showed the best performance under the tested screening conditions in terms of resolution and symmetry factor for the targeted peptide set. Hence, the operational conditions were further optimised for the identification of illegal preparations via mass spectrometry (MS) and quantification via UV. Validation was performed via accuracy profiles based on the ISO 17025 guideline. The obtained validated HILIC-method allows for the detection and quantification of the most frequently encountered illegal peptides on the internet in a total run time of 35min including post gradient equilibration and online cleaning step. Combined with a previously developed RPLC-method, the ZIC HILIC system allows for the detection and quantification of a wide spectrum of illicit peptide drugs available on the internet. Furthermore, the developed method could also be envisaged for the detection of new emerging polar peptide drugs. Copyright © 2017 Elsevier B.V. All rights reserved.
2-ethylhexyltetrabromobenzoate (EH-TBB) and bis(2-ethylhexyl)tetrabromophthalate (BEH-TEBP) are novel brominated flame retardants (FRs). BEH-TEBP is used alone as a plasticizer or with EH-TBB in polyurethane foams; both are contaminants in the indoor and outdoor environments. In ...
Schwartz, Roy; Borok, Sara; Goldstein, Michaella; Kesler, Anat; Regev, Keren; Elkayam, Ori; Habot-Wilner, Zohar
2016-01-01
To report a unique case of Behçet's disease that presented with atypical ocular manifestations. Case report. A 23-year-old homosexual male presented with bilateral anterior uveitis, vitritis, neuroretinitis and a unilateral superior hemivein occlusion with frosted branch angiitis pattern. These were accompanied by systemic findings of recurrent oral aphthous ulcers, erythema nodosum, and neurological and gastrointestinal involvement. A positive HLA-B51 examination supported the diagnosis of Behçet's disease. Neuroretinitis and frosted branch angiitis may be the clinical manifestations of Behçet's disease and may present simultaneously.
Schwartz, Roy; Borok, Sara; Goldstein, Michaella; Kesler, Anat; Regev, Keren; Elkayam, Ori; Habot-Wilner, Zohar
2016-01-01
Purpose To report a unique case of Behçet's disease that presented with atypical ocular manifestations. Methods Case report. Results A 23-year-old homosexual male presented with bilateral anterior uveitis, vitritis, neuroretinitis and a unilateral superior hemivein occlusion with frosted branch angiitis pattern. These were accompanied by systemic findings of recurrent oral aphthous ulcers, erythema nodosum, and neurological and gastrointestinal involvement. A positive HLA-B51 examination supported the diagnosis of Behçet's disease. Conclusion Neuroretinitis and frosted branch angiitis may be the clinical manifestations of Behçet's disease and may present simultaneously. PMID:27065852
Behçet's Disease and Intracardiac Thrombosis: A Report of Three Cases
Düzgün, Nurşen; Küçükşahin, Orhan; Atasoy, Kayhan Çetin; Togay Işıkay, Canan; Gerede, Demet Menekşe; Erden, Ayşe; Şahap, Seda Kaynak; İbiş, Muhammed Arif; Ateş, Aşkın
2013-01-01
We present three patients with Behçet's disease associated with intracardiac thrombus and pulmonary vascular involvement. One of these patients had also Budd-Chiari syndrome. All patients were treated with corticosteroid plus monthly intravenous cyclophosphamide as first line treatment and with no recurrences. Immunosuppressive therapy was successful in the treatment of intracardiac thrombus and also in the regression of pulmonary vascular thromboses in these patients. Intracardiac thrombus in Behçet's disease is rarely seen. Behçet's disease should be remembered in the differential diagnosis of the patients with intracardiac mass, especially in patients from the Mediterranean and Middle East populations. PMID:23936717
Green hydrophilic interaction chromatography using ethanol-water-carbon dioxide mixtures.
Pereira, Alberto dos Santos; Girón, Ana Jiménez; Admasu, Engdawork; Sandra, Pat
2010-03-01
In hydrophilic interaction chromatography (HILIC), best results are obtained with high concentrations of acetonitrile. In the framework of green chromatography, different concentrations of carbon dioxide were added to the mobile phases acetonitrile-water and ethanol-water and the impact on retention and separation in HILIC using bare silica as stationary phase was explored. The features of HILIC using enhanced-fluidity mobile phases are illustrated with the analysis of the nucleobases and a mixture containing the nucleobases and cortisol, flurbiprofen, theophylline and caffeine. For both organic constituents, the elution window is widened in function of the carbon dioxide concentration and selectivity changes. At high concentrations of carbon dioxide in ethanol, separations were similar to those obtained with acetonitrile without carbon dioxide addition.
Detecting buried explosive hazards with handheld GPR and deep learning
NASA Astrophysics Data System (ADS)
Besaw, Lance E.
2016-05-01
Buried explosive hazards (BEHs), including traditional landmines and homemade improvised explosives, have proven difficult to detect and defeat during and after conflicts around the world. Despite their various sizes, shapes and construction material, ground penetrating radar (GPR) is an excellent phenomenology for detecting BEHs due to its ability to sense localized differences in electromagnetic properties. Handheld GPR detectors are common equipment for detecting BEHs because of their flexibility (in part due to the human operator) and effectiveness in cluttered environments. With modern digital electronics and positioning systems, handheld GPR sensors can sense and map variation in electromagnetic properties while searching for BEHs. Additionally, large-scale computers have demonstrated an insatiable appetite for ingesting massive datasets and extracting meaningful relationships. This is no more evident than the maturation of deep learning artificial neural networks (ANNs) for image and speech recognition now commonplace in industry and academia. This confluence of sensing, computing and pattern recognition technologies offers great potential to develop automatic target recognition techniques to assist GPR operators searching for BEHs. In this work deep learning ANNs are used to detect BEHs and discriminate them from harmless clutter. We apply these techniques to a multi-antennae, handheld GPR with centimeter-accurate positioning system that was used to collect data over prepared lanes containing a wide range of BEHs. This work demonstrates that deep learning ANNs can automatically extract meaningful information from complex GPR signatures, complementing existing GPR anomaly detection and classification techniques.
Double pylorus in a patient with Behçet's syndrome.
Hatemi, Ibrahim; Hatemi, Gulen; Erzin, Yusuf Z; Celik, Aykut Ferhat
2015-01-01
We report a patient with Behçet's syndrome who presented with upper gastrointestinal haemorrhage. Gastroduodenoscopy showed a gastroduodenal fistula which caused the appearance of double pylorus in the antrum. The possibility of peptic ulcer disease related to non-steroidal anti-inflammatory drug use or Behçet's syndrome itself, as the cause of this rare condition in this patient is discussed.
Ferreira, Bruno Fortaleza de Aquino; Rodriguez, Ever Ernesto Caso; Prado, Leandro Lara do; Gonçalves, Celio Roberto; Hirata, Carlos Eduardo; Yamamoto, Joyce Hisae
2017-04-15
Frosted branch angiitis is a rare, severe condition. It can be either a primary or a secondary condition and is characterized by rapid deterioration of vision and fulminant retinal vasculitis that manifests as diffuse sheathing of retinal vessels, macular edema, papillitis, vitritis and anterior uveitis. We aimed to describe a case of frosted branch angiitis and cerebral venous sinus thrombosis as an initial neuro-Behçet's disease onset. Diagnosis of Behçet's disease was based on the current 2014 International Criteria for Behçet's Disease and the International consensus recommendation criteria for neuro-Behçet's disease. In addition, a literature review using search parameters of "frosted branch angiitis", "Behçet" and "neuro-Behçet" in the PubMed database is presented. A 28-year-old Brazilian pardo woman presented to our hospital with abrupt bilateral vision loss associated with recurrent aphthous oral ulcers 6 months before visual symptom onset. A fundus examination showed bilateral widespread retinal vasculitis with venous and arterial white sheathing, optic disc swelling, macular edema, and retinal hemorrhages, leading to the diagnosis of frosted branch angiitis. An extensive systemic workup for retinal vasculitis was uneventful, except for brain magnetic resonance imaging demonstrating cerebral venous sinus thrombosis and lymphocytic aseptic meningitis. A diagnosis of neuro-Behçet's disease was made, and treatment was started with methylprednisolone therapy 1 g/day for 5 consecutive days, followed by oral mycophenolate mofetil and infliximab 5 mg/kg infusion. The patient's response was rapid, with improvement of visual acuity to hand movement and counting fingers by day 7 and final visual acuity of counting fingers and 20/130. Frosted branch angiitis may be associated with infectious, noninfectious, or idiopathic causes. An extensive workup should be done to exclude systemic vasculitis such as Behçet's disease. Treatment with systemic steroids must be promptly initiated in association with specific treatment aimed at inflammation control and blindness risk reduction.
Miura, Chitose; Matsunaga, Hisami; Haginaka, Jun
2016-08-05
Molecularly imprinted polymers (MIPs) for caffeic acid (CA) were prepared using 4-vinylpyridine and methacrylamide (MAM) as functional monomers, divinylbenzene as a crosslinker and acetonitrile-toluene (3:1, v/v) as a porogen by precipitation polymerization. The use of MAM as the co-monomer resulted in the formation of microsphere MIPs and non-imprinted polymers (NIPs) with ca. 3- and 5-μm particle diameters, respectively. Binding experiments and Scatchard analyses revealed that the binding capacity and affinity of the MIP to CA are higher than those of the NIP. The retention and molecular-recognition properties of the prepared MIPs were evaluated using water-acetonitrile and sodium phosphate buffer-acetonitrile as mobile phases in hydrophilic interaction chromatography (HILIC) and reversed-phase chromatography, respectively. In HILIC mode, the MIP showed higher molecular-recognition ability for CA than in reversed-phase mode. In addition to shape recognition, hydrophilic interactions seem to work for the recognition of CA on the MIP in HILIC mode, while hydrogen bonding and hydrophobic interactions seem to work for the recognition of CA in reversed-phase mode. The MIP had a specific molecular-recognition ability for CA in HILIC mode, while other structurally related compounds, such as chlorogenic acid (CGA), gallic acid, protocatechuic acid and vanillic acid, could not be recognized by the MIP. Furthermore, the MIP was successfully applied for extraction of CA and CGA in the leaves of Eucommia ulmodies in HILIC mode. Copyright © 2015 Elsevier B.V. All rights reserved.
Iverson, Chad D; Lucy, Charles A
2014-12-19
Most stationary phases for hydrophilic interaction liquid chromatography (HILIC) and reversed phase liquid chromatography (RPLC) are based on silica. Porous graphitic carbon (PGC) is an attractive alternative to silica-based phases due to its chemical and thermal stability, and unique selectivity. However, native PGC is strongly hydrophobic and in some instances excessively retentive. PGC particles with covalently attached aniline groups (Dimethylaniline-PGC and Aniline-PGC) were synthesized to alter the surface polarity of PGC. First, the diazonium salt of N,N-dimethyl-p-phenylenediamine or 4-nitroaniline was adsorbed onto the PGC surface. The adsorbed salt was reduced with sodium borohydride and (Aniline-PGC only) the nitro group was further reduced with iron powder to the aniline. X-ray photoelectron spectroscopy confirmed the surface functionalities and that these moieties were introduced to the surface at concentrations of 0.9 and 2.1molecules/nm(2), respectively. These modified PGC phases (especially Aniline-PGC) were evaluated as HILIC and reversed phases. The Dimethylaniline-PGC phase displayed only weak HILIC retention of phenolic solutes. In contrast, the Aniline-PGC phase displayed up to nearly a 7-fold increase in HILIC retention vs. an aniline-silica phase and selectivity that differed from 10 other HILIC phases. Introduction of aniline groups to the PGC surface reduced the RPLC retentivity of PGC up to more than 5-fold and improved the separation efficiency up to 6-fold. The chromatographic performance of Aniline-PGC is demonstrated by separations of nucleotides, nucleosides, carboxylic acids, basic pharmaceuticals, and other compounds. Copyright © 2014 Elsevier B.V. All rights reserved.
Behçet's syndrome pathophysiology and potential therapeutic targets.
Emmi, Giacomo; Silvestri, Elena; Squatrito, Danilo; D'Elios, Mario Milco; Ciucciarelli, Lucia; Prisco, Domenico; Emmi, Lorenzo
2014-04-01
Behçet syndrome is a systemic inflammatory disorder characterized by multiorgan involvement such as oral and genital ulcers, uveitis, skin lesions as well as by less frequent, but often more severe, central nervous system and vascular manifestations. The pathogenetic mechanisms are still incompletely known; however the interaction between a specific genetic background and environmental or infectious factors certainly contributes to the immune dysregulation that characterizes this disease. The discovery of new immunological pathways in Behçet syndrome pathogenesis may help us to set up new treatments. In this review, we will focus our attention on the possible mechanisms underlying Behçet syndrome pathogenesis and their potential role as novel therapeutic targets.
New Insights in the Clinical Understanding of Behçet's Disease
Cho, Sung Bin; Cho, Suhyun
2012-01-01
Behçet's disease is a chronic relapsing multisystemic inflammatory disorder characterized by four major symptoms (oral aphthous ulcers, genital ulcers, skin lesions, and ocular lesions) and occasionally by five minor symptoms (arthritis, gastrointestinal ulcers, epididymitis, vascular lesions, and central nervous system symptoms). Although the etiology of Behçet's disease is still unknown, there have been recent advances in immunopathogenic studies, genome-wide association studies, animal models, diagnostic markers, and new biological agents. These advances have improved the clinical understanding of Behçet's disease and have enabled us to develop new treatment strategies for this intractable disease, which remains one of the leading causes of blindness. PMID:22187230
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knudsen, Gabriel A., E-mail: gabriel.knudsen@nih.g
2-Ethylhexyl-2,3,4,5-tetrabromobenzoate (EH-TBB) and bis(2-ethylhexyl)tetrabromophthalate (BEH-TEBP) are novel brominated flame retardants used in consumer products. A parallelogram approach was used to predict human dermal absorption and flux for EH-TBB and BEH-TEBP. [{sup 14}C]-EH-TBB or [{sup 14}C]-BEH-TEBP was applied to human or rat skin at 100 nmol/cm{sup 2} using a flow-through system. Intact rats received analogous dermal doses. Treated skin was washed and tape-stripped to remove “unabsorbed” [{sup 14}C]-radioactivity after continuous exposure (24 h). “Absorbed” was quantified using dermally retained [{sup 14}C]-radioactivity; “penetrated” was calculated based on [{sup 14}C]-radioactivity in media (in vitro) or excreta + tissues (in vivo). Human skin absorbedmore » EH-TBB (24 ± 1%) while 0.2 ± 0.1% penetrated skin. Rat skin absorbed more (51 ± 10%) and was more permeable (2 ± 0.5%) to EH-TBB in vitro; maximal EH-TBB flux was 11 ± 7 and 102 ± 24 pmol-eq/cm{sup 2}/h for human and rat skin, respectively. In vivo, 27 ± 5% was absorbed and 13% reached systemic circulation after 24 h (maximum flux was 464 ± 65 pmol-eq/cm{sup 2}/h). BEH-TEBP in vitro penetrance was minimal (< 0.01%) for rat or human skin. BEH-TEBP absorption was 12 ± 11% for human skin and 41 ± 3% for rat skin. In vivo, total absorption was 27 ± 9%; 1.2% reached systemic circulation. In vitro maximal BEH-TEBP flux was 0.3 ± 0.2 and 1 ± 0.3 pmol-eq/cm{sup 2}/h for human and rat skin; in vivo maximum flux for rat skin was 16 ± 7 pmol-eq/cm{sup 2}/h. EH-TBB was metabolized in rat and human skin to tetrabromobenzoic acid. BEH-TEBP-derived [{sup 14}C]-radioactivity in the perfusion media could not be characterized. < 1% of the dose of EH-TBB and BEH-TEHP is estimated to reach the systemic circulation following human dermal exposure under the conditions tested. Chemical compounds studied in this article: 2-Ethylhexyl 2,3,4,5-tetrabromobenzoate (PubChem CID: 71316600; CAS No. 183658-27-7 FW: 549.92 g/mol logP{sub est}: 7.73–8.75 (12)) Abdallah et al., 2015a. Other published abbreviations for 2-ethylhexyl-2,3,4,5-tetrabromobenzoate are TBB EHTeBB or EHTBB Abdallah and Harrad, 2011. bis(2-ethylhexyl) tetrabromophthalate (PubChem CID: 117291; CAS No. 26040-51-7 FW: 706.14 g/mol logP{sub est}: 9.48-11.95 (12)). Other published abbreviations for bis(2-ethylhexyl)tetrabromophthalate are TeBrDEPH TBPH or BEHTBP. - Highlights: • Human skin maximal flux was 11 ± 7 (EH-TBB) & 0.3 ± 0.2 (BEH-TEBP) pmol-eq/cm{sup 2}/h. • Predicted systemic bioavailability was < 1% for either chemical after 24 h. • Skin retained EH-TBB & BEH-TEBP after 24 h dermal exposure. • EH-TBB was hydrolyzed to tetrabromobenzoic acid; BEH-TEBP was not metabolized. • Skin contact is an important route of human exposure to EH-TBB & BEH-TEBP.« less
Behçet's disease (syndrome) with myalgia and its response to intravenous amino acids: a case series.
Bryan, Thomas
2011-09-01
To present a case series of patients with refractory Behçet's disease who presented with myalgia and with signs such as mouth and genital ulcerations and skin lesions and were treated with intravenous amino acids. Case series of patients with Behçet's Disease who presented to a clinical practice devoted to Pain Medicine and Neurology between 2000 and 2009 for treatment of myalgia. All patients were treated with prednisone 60 mg by mouth daily for exacerbations of their disease. When this failed, eleven patients received intravenous administration of amino acids (Procalamine). Ten of eleven patients had a complete resolution of their Behçet's exacerbation, including myalgia; their painful ulcers became painless and began to heal with the infusion of amino acids for 2-5 days. Physicians treating myalgia should observe for signs of Behçet's disease, such as oral and genital ulcerations, and consider intravenous amino acids if steroids are not effective. Wiley Periodicals, Inc.
Management of Behçet's syndrome.
Ozguler, Yesim; Hatemi, Gulen
2016-01-01
Current trends in the management of Behçet's syndrome will be reviewed in this article. Biologic agents have gained increasing importance over the years in the management of Behçet's syndrome. Long-term results of observational studies have shown that anti-tumor necrosis factor agents may be effective in Behçet's syndrome patients with refractory eye involvement. Case series reporting about use of anti-tumor necrosis factor agents in vascular and gastrointestinal involvement have also shown good results. Caution is required for infectious complications with these agents. Apremilast is an immunomodulatory agent that works through phosphodiesterase 4 inhibition. A randomized controlled trial has shown that it is effective for the management of oral and genital ulcers and is generally well tolerated. The outcome of Behçet's syndrome with major organ involvement has improved with more effective management strategies, especially with the use of biologic agents in severe cases. Controlled trials are needed to guide physicians in making treatment decisions.
Major vessel involvement in Behçet disease.
Calamia, Kenneth T; Schirmer, Michael; Melikoglu, Melike
2005-01-01
Large vessel vasculitis occurs in a subgroup of patients with Behçet disease at high risk for disease-related morbidity and mortality. Recognition of patients at risk, early detection of vasculitis, and the need for aggressive treatment are essential for optimal care of these patients. The authors review the clinical spectrum and management of large vessel problems in Behçet disease, highlighting contributions over the past year. Vasculo-Behçet patients are at risk for multiple vessel-related complications including thromboses, stenoses, occlusions, and aneurysms. A number of factors may contribute to thrombosis in individual cases, but the primary reason for clot seems to reside in the inflammatory process in the arterial wall, still incompletely understood. An appreciation for the challenges in the perioperative period requires the joint efforts of physicians and surgeons, and fuels the study of alternate, less invasive procedures for Behçet patients. Because of earlier recognition, aggressive medical treatment, and novel surgical procedures, the morbidity and mortality of large vessel vasculitis in Behçet disease are beginning to change. In the absence of controlled treatment studies, reports of clinical experience remain an important source of information for clinicians. Identification of patients at risk for vascular complications remains a priority.
Complete temperature profiles in ultra-high-pressure liquid chromatography columns.
Gritti, Fabrice; Guiochon, Georges
2008-07-01
The temperature profiles were calculated along and across seven packed columns (lengths 30, 50, 100, and 150 mm, i.d., 1 and 2.1 mm, all packed with Acquity UPLC, BEH-C 18 particles, average d(p) approximately 1.7 microm) and their stainless steel tubes (o.d. 4.53 and 6.35 mm). These columns were kept horizontal and sheltered from forced air convection (i.e., under still air conditions), at room temperature. They were all percolated with pure acetonitrile, either under the maximum pressure drop (1034 bar) or at the maximum flow rate (2 mL/min) permitted by the chromatograph. The heat balance equation of chromatographic columns was discretized and solved numerically with minimum approximation. Both the compressibility and the thermal expansion of the eluent were taken into account. The boundary conditions were determined from the experimental measurements of the column inlet pressure and of the temperature profile along the column wall, which were made with a precision better than +/-0.1 K. These calculation results provide the 3-D temperature profiles along and across the columns. The axial and radial temperature gradients are discussed in relationship with the experimental conditions used. The temperature map obtained permits a prediction of the chromatographic data obtained under a very high pressure gradient.
Chandra, Preeti; Kannujia, Rekha; Saxena, Ankita; Srivastava, Mukesh; Bahadur, Lal; Pal, Mahesh; Singh, Bhim Pratap; Kumar Ojha, Sanjeev; Kumar, Brijesh
2016-09-10
An ultra-high performance liquid chromatography electrospray ionization tandem mass spectrometry method has been developed and validated for simultaneous quantification of six major bioactive compounds in five varieties of Withania somnifera in various plant parts (leaf, stem and root). The analysis was accomplished on Waters ACQUITY UPLC BEH C18 column with linear gradient elution of water/formic acid (0.1%) and acetonitrile at a flow rate of 0.3mLmin(-1). The proposed method was validated with acceptable linearity (r(2), 0.9989-0.9998), precision (RSD, 0.16-2.01%), stability (RSD, 1.04-1.62%) and recovery (RSD ≤2.45%), under optimum conditions. The method was also successfully applied for the simultaneous determination of six marker compounds in twenty-six marketed formulations. Hierarchical cluster analysis and principal component analysis were applied to discriminate these twenty-six batches based on characteristics of the bioactive compounds. The results indicated that this method is advance, rapid, sensitive and suitable to reveal the quality of Withania somnifera and also capable of performing quality evaluation of polyherbal formulations having similar markers/raw herbs. Copyright © 2016 Elsevier B.V. All rights reserved.
Cantarini, Luca; Vitale, Antonio; Bersani, Giulia; Nieves, Laura Martin; Cattalini, Marco; Lopalco, Giuseppe; Caso, Francesco; Costa, Luisa; Iannone, Florenzo; Lapadula, Giovanni; Galeazzi, Mauro; Ceribelli, Angela; Brunetta, Enrico; Selmi, Carlo; Rigante, Donato
2016-02-01
The pediatric syndrome characterized by periodic fever, aphthous stomatitis, pharyngitis, and cervical adenitis (PFAPA) and adult Behçet's disease share some clinical manifestations and are both polygenic autoinflammatory disorders with interleukin-1β showing to play a pivotal role. However, the diagnosis is mostly clinical and we hypothesize that specific criteria may be addressed differently by different physicians. To determine the diagnostic variability, we compared the answers of 80 patients with a definite diagnosis of Behçet's disease (age 42.1 ± 13.7 years) obtained by separate telephone interviews conducted by a rheumatologist, a pediatrician, and an internist working largely in the field of autoinflammatory disorders. Questions were related to the age of symptom onset, the occurrence of recurrent fevers during childhood, and the association with oral aphthosis, cervical adenitis and/or pharyngitis, previous treatments, possible growth impairment, the time lapse between PFAPA-like symptoms and the onset of Behçet's disease, and the occurrence of Behçet-related manifestation during childhood. The rheumatologist identified 30 % of patients with Behçet's disease fulfilling PFAPA syndrome diagnostic criteria, compared to the pediatrician and the internist identifying 10 and 7.5 %, respectively. Most of the patients suffered from recurrent oral aphthosis in childhood also without fever (50, 39, and 48 % with each interviewer), yet no patient fulfilled the Behçet's disease diagnostic criteria. Our data suggest that physician awareness and expertise are central to the diagnosis of autoinflammatory disorders through an accurate collection of the medical history.
Hydrophilic interaction liquid chromatography in the speciation analysis of selenium.
Sentkowska, Aleksandra; Pyrzynska, Krystyna
2018-02-01
The hydrophilic interaction liquid chromatography (HILIC) coupled to mass spectrometry was employed to study retention behavior of selected selenium compounds using two different HILIC stationary phases: silica and zwitterionic. Two organic solvents - acetonitrile and methanol - were compared as a component of mobile phase. Separation parameters such as a content of organic modifier, the eluent pH and inorganic buffer concentration were investigated. Based on all observations, methanol seems to be beneficial for the separation of studied compounds. The optimal HILIC separation method involved silica column and eluent composed of 85% MeOH and CH 3 COONH 4 (8 mM, pH 7) was compared to RP method in terms of time of the single run, the separation efficiency and limit of detection. Copyright © 2018 Elsevier B.V. All rights reserved.
Vascular endothelial function and oxidative stress mechanisms in patients with Behçet's syndrome.
Chambers, J C; Haskard, D O; Kooner, J S
2001-02-01
We sought to test the hypothesis that vascular endothelial function is impaired in Behçet's syndrome and reflects increased levels of oxidative stress. Behçet's syndrome is a multisystem inflammatory disorder commonly complicated by vascular thrombosis and arterial aneurysm formation. The precise mechanisms underlying vascular disease in Behçet's syndrome are not known. We studied 19 patients with Behçet's syndrome (18 to 50 years old, 9 men) and 21 healthy volunteers (18 to 50 years old, 10 men). Brachial artery flow-mediated dilation (endothelium-dependent), and nitroglycerin (NTG)-induced dilation (endothelium-independent) were measured. To investigate oxidative stress mechanisms, vascular studies were repeated 1 h after administration of vitamin C (1 g, intravenous) in 12 patients and 12 control subjects. Flow-mediated dilation was reduced in patients with Behcet's syndrome as compared with control subjects (0.7 +/- 0.9% vs. 5.7 +/- 0.9%, p = 0.001). In contrast, there were no significant differences in the brachial artery diameter (4.2 +/- 0.2 vs. 4.0 +/- 0.2 mm, p = 0.47) or NTG-induced dilation (19.7 +/- 1.9% vs. 19.7 +/- 1.2%, p = 0.98). In regression analysis, Behçet's syndrome was associated with impaired flow-mediated dilation independent of age, gender, brachial artery diameter, blood pressure, cholesterol and glucose. Vitamin C increased flow-mediated dilation in Behçet's syndrome (0.2 +/- 0.7% to 3.5 +/- 1.0%, p = 0.002), but not in control subjects (4.3 +/- 0.6% to 4.7 +/- 0.4%, p = 0.51). In both groups, NTG-induced dilation and brachial artery diameter were unchanged after vitamin C treatment. Vascular endothelial function is impaired in Behcet's syndrome and can be rapidly improved by vitamin C treatment. Our results support a role for oxidative stress in the pathophysiology of Behçet's syndrome and provide a rationale for therapeutic studies aimed at reducing vascular complications in this disorder.
Update on the therapy of Behçet disease
Saleh, Zeinab
2014-01-01
Behçet disease is a chronic inflammatory systemic disorder, characterized by a relapsing and remitting course. It manifests with oral and genital ulcerations, skin lesions, uveitis, and vascular, central nervous system and gastrointestinal involvement. The main histopathological finding is a widespread vasculitis of the arteries and veins of any size. The cause of this disease is presumed to be multifactorial involving infectious triggers, genetic predisposition, and dysregulation of the immune system. As the clinical expression of Behçet disease is heterogeneous, pharmacological therapy is variable and depends largely on the severity of the disease and organ involvement. Treatment of Behçet disease continues to be based largely on anecdotal case reports, case series, and a few randomized clinical trials. PMID:24790727
Knudsen, Gabriel A.; Hughes, Michael F.; Sanders, J. Michael; Hall, Samantha M.; Birnbaum, Linda S.
2016-01-01
2-ethylhexyl-2,3,4,5-tetrabromobenzoate (EH-TBB) and bis(2-ethylhexyl)tetrabromophthalate (BEH-TEBP) are novel brominated flame retardants used in consumer products. A parallelogram approach was used to predict human dermal absorption and flux for EH-TBB and BEH-TEBP. [14C]-EH-TBB or [14C]-BEH-TEBP was applied to human or rat skin at 100 nmol/cm2 using a flow-through system. Intact rats received analogous dermal doses. Treated skin was washed and tape-stripped to remove “unabsorbed” [14C]-radioactivity after continuous exposure (24h). “Absorbed” was quantified using dermally retained [14C]-radioactivity; “penetrated” was calculated based on [14C]-radioactivity in media (in vitro) or excreta+tissues (in vivo). Human skin absorbed EH-TBB (24±1%) while 0.2±0.1% penetrated skin. Rat skin absorbed more (51±10%) and was more permeable (2±0.5%) to EH-TBB in vitro; maximal EH-TBB flux was 11±7 and 102±24 pmol-eq/cm2/h for human and rat skin, respectively. In vivo, 27±5% was absorbed and 13% reached systemic circulation after 24 h (maximum flux was 464±65 pmol-eq/cm2/h). BEH-TEBP in vitro penetrance was minimal (<0.01%) for rat or human skin. BEH-TEBP absorption was 12±11% for human skin and 41±3% for rat skin. In vivo, total absorption was 27±9%; 1.2% reached systemic circulation. In vitro maximal BEH-TEBP flux was 0.3±0.2 and 1±0.3 pmol-eq/cm2/h for human and rat skin; in vivo maximum flux for rat skin was 16±7 pmol-eq/cm2/h. EH-TBB was metabolized in rat and human skin to tetrabromobenzoic acid. BEH-TEBP-derived [14C]-radioactivity in the perfusion media could not be characterized. Less than 1% of the dose of EH-TBB and BEH-TEHP is estimated to reach the systemic circulation following human dermal exposure under the conditions tested. PMID:27732871
Gu, Liqiang; Hou, Pengyi; Zhang, Ruowen; Liu, Ziying; Bi, Kaishun; Chen, Xiaohui
2016-10-15
A Previous metabolomics study has demonstrated that tyrosine metabolism might be disrupted by treating with Semen Strychni on the cell nephrotoxicity model. To investigate the relationship between Semen Strychni alkaloids (SAs) and endogenous tyrosine, tyramine under the nephrotoxicity condition, an HILIC-ESI-MS/MS based analytical strategy was applied in this study. Based on the established Semen Strychni nephrotoxicity cell model, strychnine and brucine were identified and screened as the main SAs by an HPLC-Q Exactive hybrid quadrupole Orbitrap mass system. Then, a sensitive HILIC-ESI-MS/MS method was developed to simultaneously monitor strychnine, brucine, tyrosine and tyramine in cell lysate. The analytes were separated by a Shiseido CAPCELL CORE PC (150mm×2.1mm, 2.7μm) HILIC column in an acetonitrile/0.1% formic acid gradient system. All the calibration curves were linear with regression coefficients above 0.9924. The absolute recoveries were more than 80.5% and the matrix effects were between 91.6%-107.0%. With the developed method, analytes were successfully determined in cell lysates. Decreased levels of tyrosine and tyramine were observed only in combination with increased levels of SAs, indicating that the disturbance of tyrosine metabolism might be induced by the accumulation of SAs in kidney cell after exposure of Semen Strychni. The HILIC-ESI-MS/MS based analytical strategy is a useful tool to reveal the relationships between the toxic herb components and the endogenous metabolite profiling in the toxicity investigation of herb medicines. Copyright © 2016 Elsevier B.V. All rights reserved.
Mixed mode HILIC/anion exchange separations on latex coated silica monoliths.
Ibrahim, Mohammed E A; Lucy, Charles A
2012-10-15
Bare silica monoliths do not possess anion exchange sites hence they show low retention for anions. Moreover, bare silica monoliths show low retention in hydrophilic interaction liquid chromatography (HILIC). Coating the silica surface with cationic nanoparticles e.g. AS9-SC (latex A), AS12A (latex B) and DNApac (latex C) increases the thickness of the water layer on the Onyx silica monolith 8-10 times enabling HILIC retention when a high % acetonitrile (ACN) mobile phase is used. The formed water layer by itself is not sufficient to perform good separation of the studied anions (acetate, formate, nitrate, bromate, thiocyanate and iodide). On the other hand, the latex nanoparticles introduce positively charged sites, making anion exchange chromatography possible, with the anion exchange capacity varying with the latex adsorbed (44.1 ± 0.2, 4.4 ± 0.1 and 14.0 ± 0.7 μeq/column for latex A, B and C, respectively). Latex A nanoparticles which provided the highest ion exchange capacity separated all tested anions with reasonable resolution. Fast separation (2.5 min) of acetate, formate, nitrate, bromate, thiocyanate and iodide was performed using the latex A coated silica monolith. The obtained efficiencies are 13,000-50,000 plates/m at 3 mL/min with a minimum resolution of 0.85. Retention is mixed mode under HILIC conditions with HILIC dominating for the kosmotropic anions and ion exchange dominating for the chaotropic anions. The two different brands of silica monoliths (Merck Chromolith and Phenomenex Onyx) coated with the same latex A nanoparticles displayed similar water layer volumes, ion exchange capacity and selectivity. Copyright © 2012 Elsevier B.V. All rights reserved.
Perrenoud, Alexandre Grand-Guillaume; Farrell, William P; Aurigemma, Christine M; Aurigemma, Nicole C; Fekete, Szabolcs; Guillarme, Davy
2014-09-19
Superficially porous particles (SPP), or core shell particles, which consist of a non-porous silica core surrounded by a thin shell of porous silica, have gained popularity as a solid support for chromatography over the last decade. In the present study, five unbonded silica, one diol, and two ethylpyridine (2-ethyl and 4-ethyl) SPP columns were evaluated under SFC conditions using two mixtures, one with 17 drug-like compounds and the other one with 7 drug-like basic compounds. Three of the SPP phases, SunShell™ 2-ethylpyridine (2-EP), Poroshell™ HILIC, and Ascentis(®) Express HILIC, exhibited superior performances relative to the others (reduced theoretical plate height (hmin) values of 1.9-2.5 for neutral compounds). When accounting for both achievable plate count and permeability of the support using kinetic plot evaluation, the Cortecs™ HILIC 1.6μm and Ascentis(®) Express HILIC 2.7μm phases were found to be the best choices among tested SPPs to reach efficiencies up to 30,000 plates in the minimum amount of time. For desired efficiencies ranging from 30,000 to 60,000 plates, the SunShell™ 2-EP 2.6μm column clearly outperformed all other SPPs. With the addition of a mobile phase additive such as 10mM ammonium formate, which was required to elute the basic components with sharp peaks, the Poroshell™ HILIC, SunShell™ Diol and SunShell™ 2-EP phases represent the most orthogonal SPP columns with the highest peak capacities. This study demonstrates the obvious benefits of using columns packed with SPP on current SFC instrumentation. Copyright © 2014 Elsevier B.V. All rights reserved.
Banas, Tomasz; Pitynski, Kazimierz; Mikos, Marcin; Cielecka-Kuszyk, Joanna
2017-09-13
DNA fragmentation factor 40 (DFF40) is a key executor of apoptosis. It localizes to the nucleus together with DNA fragmentation factor 45 (DFF45), which acts as a DFF40 inhibitor and chaperone. B-cell lymphoma (Bcl-2) protein is a proven antiapoptotic factor present in the cytoplasm. In this study, we aimed to investigate DFF40, DFF45, and Bcl-2 immunoexpression in endometrial polyps (EPs) and benign endometrial hyperplasia (BEH) tissue compared with that in normal proliferative endometrium (NPE) and normal secretory endometrium (NSE) as well as normal post menopausal endometrium (NAE). This study used archived samples from 65 and 62 cases of EPs and BEH, respectively. The control group consisted of 52 NPE, 54 NSE, and 54 NAE specimens. Immunohistochemistry was used to detect DFF40, DFF45, and Bcl-2. DFF40, DFF45, and Bcl-2 were more highly expressed in the glandular layer of EPs and BEH compared with the stroma, and this was not influenced by menopausal status. Both glandular and stromal expression of DFF40, DFF45, and Bcl-2 were significantly higher in EPs compared with NPE, NSE, and NAE. Glandular BEH tissue showed significantly higher DFF40, DFF45, and Bcl-2 expression than in NPE, NSE, and NAE. No differences in the glandular expression of DFF40, DFF45, and Bcl-2 were observed between EP and BEH tissues, while Bcl-2 stromal expression in BEH was significantly lower than in EPs. Glandular, menopause-independent DFF40, DFF45, and Bcl-2 overexpression may play an important role in the pathogenesis of EPs and BEH.
Heart-Rate Recovery Index Is Impaired in Behçet's Disease
Kaya, Ergun Baris; Yorgun, Hikmet; Akdogan, Ali; Ates, Ahmet Hakan; Canpolat, Ugur; Sunman, Hamza; Aytemir, Kudret; Tokgozoglu, Lale; Kabakci, Giray; Calguneri, Meral; Ozkutlu, Hilmi; Oto, Ali
2009-01-01
Behçet's disease, a multisystemic inflammatory disorder, has been associated with a number of cardiovascular dysfunctions, including ventricular arrhythmias and sudden cardiac death. Heart-rate recovery after exercise can provide both an estimate of impaired parasympathetic tone and a prognosis in regard to all-cause and cardiovascular death. The aim of our study was to evaluate heart-rate recovery in Behçet's disease From January through July 2008, we examined at our outpatient clinic and prospectively enrolled 30 consecutive patients with Behçet's disease and 50 healthy control participants who were matched for age and sex. Basal electrocardiography, echocardiography, and treadmill exercise testing were performed in all patients and control participants. The heart-rate recovery index was calculated in the usual manner, by subtracting the 1st-minute (Rec1), 2nd-minute (Rec2), and 3rd-minute (Rec3) recovery heart rates from the maximal heart rate after exercise stress testing. Patients with Behçet's disease exhibited significantly lower heart-rate recovery numbers, compared with healthy control participants: Rec1, 24.28 ± 8.2 vs 34.4 ± 7.6, P = 0.002; Rec2, 49.28 ± 11.2 vs 57.5 ± 7.0, P < 0.05; and Rec3, 56.2 ± 12.11 vs 67.4 ± 8.7, P = 0.014. To our knowledge, this is the 1st study that shows an impaired heart-rate recovery index (indicative of reduced parasympathetic activity) among patients with Behçet's disease. Given the independent prognostic value of the heart-rate recovery index, our results may explain the increased occurrence of arrhythmias and sudden cardiac death in Behçet's patients. Therefore, this index may be clinically useful in the identification of high-risk patients. PMID:19693299
Constitutional trisomy 8 and Behçet syndrome.
Becker, Kristin; Fitzgerald, Oliver; Green, Andrew J; Keogan, Mary; Newbury-Ecob, Ruth; Greenhalgh, Lynn; Withers, Stephen; Hollox, Edward J; Aldred, Patricia M R; Armour, John A L
2009-05-01
The characteristic clinical features of constitutional trisomy 8 include varying degrees of developmental delay, joint contractures and deep palmar and plantar creases. There is an established literature, which describes features of Behçet syndrome occurring in phenotypically normal individuals with myelodysplastic syndromes and trisomy 8 in their bone marrow. In this article, we describe four patients with constitutional trisomy 8, all with varying clinical phenotypes, who developed features of Behçet, in particular but not exclusively mucocutaneous ulceration. In addition, we examined gene copy numbers of the variable-number neutrophil defensin genes DEFA1A3 in one of the cases (case 1) and her parents, together with 14 cases of Behçet syndrome in comparison with 121 normal controls. The gene copy number was highest in case 1 (copy number 14) and was also increased in her parents (both copy number 9). However the mean copy number for DEFA1A3 among the 14 Behçet syndrome patients was actually lower (5.1) than among the controls (mean of 6.8 copies). Thus, we conclude that patients with constitutional trisomy 8 and those with trisomy 8 confined to the bone marrow are both at increased risk of developing features of Behçet syndrome. The mechanism may relate to increased chromosome 8 gene dosage with further analysis of candidate genes on chromosome 8 required.
Deep learning algorithms for detecting explosive hazards in ground penetrating radar data
NASA Astrophysics Data System (ADS)
Besaw, Lance E.; Stimac, Philip J.
2014-05-01
Buried explosive hazards (BEHs) have been, and continue to be, one of the most deadly threats in modern conflicts. Current handheld sensors rely on a highly trained operator for them to be effective in detecting BEHs. New algorithms are needed to reduce the burden on the operator and improve the performance of handheld BEH detectors. Traditional anomaly detection and discrimination algorithms use "hand-engineered" feature extraction techniques to characterize and classify threats. In this work we use a Deep Belief Network (DBN) to transcend the traditional approaches of BEH detection (e.g., principal component analysis and real-time novelty detection techniques). DBNs are pretrained using an unsupervised learning algorithm to generate compressed representations of unlabeled input data and form feature detectors. They are then fine-tuned using a supervised learning algorithm to form a predictive model. Using ground penetrating radar (GPR) data collected by a robotic cart swinging a handheld detector, our research demonstrates that relatively small DBNs can learn to model GPR background signals and detect BEHs with an acceptable false alarm rate (FAR). In this work, our DBNs achieved 91% probability of detection (Pd) with 1.4 false alarms per square meter when evaluated on anti-tank and anti-personnel targets at temperate and arid test sites. This research demonstrates that DBNs are a viable approach to detect and classify BEHs.
Ren, Shu-Ting; Xu, Chang-Fu; Du, Yun-Xia; Gao, Xiao-Li; Sun, Ying; Jiang, Yi-Na
2012-07-01
The natural outcome of melamine-induced bladder stones (cystoliths) with bladder epithelial hyperplasia (BEH) after melamine withdrawn is unclear. Using an ideal dual-model system, three experiments were conducted in BALB/c mice. Each experiment included a control, model 1 and model 2 groups. The mice were fed a regular diet in controls or a 9373 ppm melamine diet in models, and the first day was designated as dosing day 1. The melamine diet was then replaced by the regular diet in the model 2 groups, and the first day was designated as post-dosing day 1. On dosing days 12, 35 and 49, the incidence of cystoliths and diffusely active BEH was 8/8 in the mice of three model 1 groups. On post-dosing days 1, 4 and 8, in the mice of three model 2 groups, the incidence of cystoliths was 2/8, 0/8 and 1/8, respectively, and the progressive regression of BEH was observed. In conclusion, both the stones and BEH have the natural property of rapid development and rapid regression, and melamine withdrawn plays a key role in the stone dissolution-discharge necessary for BEH regression. BEH may be reversible after the discharge of the stones. The conventionally conservative therapy is thus reasonable. Copyright © 2012 Elsevier Ltd. All rights reserved.
Simultaneous determination of three anticonvulsants using hydrophilic interaction LC-MS.
Oertel, Reinhard; Arenz, Norman; Pietsch, Jörg; Kirch, Wilhelm
2009-01-01
A specific and automated method was developed to quantify the anticonvulsants gabapentin, pregabalin and vigabatrin simultaneously in human serum. Samples were prepared with a protein precipitation. The hydrophilic interaction chromatography (HILIC) with a mobile phase gradient was used to divide off ions of the matrix and for separation of the analytes. Four different HILIC-columns and two different column temperatures were tested. The Tosoh-Amid column gave the best results: single small peaks. The anticonvulsants were detected in the multiple reaction monitoring mode (MRM) with ESI-MS-MS. Using a volume of 100 microL biological sample the lowest point of the standard curve, i.e. the lower LOQs were 312 ng/mL. The described HILIC-MS-MS method is suitable for therapeutic drug monitoring and for clinical and pharmcokinetical investigations of the anticonvulsives.
Drug screening in medical examiner casework by high-resolution mass spectrometry (UPLC-MSE-TOF).
Rosano, Thomas G; Wood, Michelle; Ihenetu, Kenneth; Swift, Thomas A
2013-10-01
Postmortem drug findings yield important analytical evidence in medical examiner casework, and chromatography coupled with nominal mass spectrometry (MS) serves as the predominant general unknown screening approach. We report screening by ultra performance liquid chromatography (UPLC) coupled with hybrid quadrupole time-of-flight mass spectrometer (MS(E)-TOF), with comparison to previously validated nominal mass UPLC-MS and UPLC-MS-MS methods. UPLC-MS(E)-TOF screening for over 950 toxicologically relevant drugs and metabolites was performed in a full-spectrum (m/z 50-1,000) mode using an MS(E) acquisition of both molecular and fragment ion data at low (6 eV) and ramped (10-40 eV) collision energies. Mass error averaged 1.27 ppm for a large panel of reference drugs and metabolites. The limit of detection by UPLC-MS(E)-TOF ranges from 0.5 to 100 ng/mL and compares closely with UPLC-MS-MS. The influence of column recovery and matrix effect on the limit of detection was demonstrated with ion suppression by matrix components correlating closely with early and late eluting reference analytes. Drug and metabolite findings by UPLC-MS(E)-TOF were compared with UPLC-MS and UPLC-MS-MS analyses of postmortem blood in 300 medical examiner cases. Positive findings by all methods totaled 1,528, with a detection rate of 57% by UPLC-MS, 72% by UPLC-MS-MS and 80% by combined UPLC-MS and UPLC-MS-MS screening. Compared with nominal mass screening methods, UPLC-MS(E)-TOF screening resulted in a 99% detection rate and, in addition, offered the potential for the detection of nontargeted analytes via high-resolution acquisition of molecular and fragment ion data.
Isogai, E; Ohno, S; Kotake, S; Isogai, H; Tsurumizu, T; Fujii, N; Yokota, K; Syuto, B; Yamaguchi, M; Matsuda, H
1990-01-01
Zymosan-induced chemiluminescence was investigated in whole blood and in neutrophils: in both, the peak count was frequently elevated in Behçet's disease, and was significantly higher than in healthy controls; similarly the peak time was shorter. There were more uncommon serotypes of Streptococcus sanguis in the oral flora of patients with Behçet's disease. Common serotypes were present in the flora of healthy controls, but not in patients with the disease. The percentage of Strep. sanguis in the oral flora was significantly correlated with the level of chemiluminescence response. Thus infection with uncommon serotypes of Strep. sanguis may play a role in the aetiology of Behçet's disease.
Wang, Jixia; Kong, Song; Yan, Jingyu; Jin, Gaowa; Guo, Zhimou; Shen, Aijin; Xu, Junyan; Zhang, Xiuli; Zou, Lijuan; Liang, Xinmiao
2014-06-01
Peptide drugs play a critical role in therapeutic treatment. However, as the complexity of plasma, determination of peptide drugs using liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a daunting task. To solve this problem, hydrophilic interaction liquid chromatography-solid phase extraction (HILIC-SPE) directly combined with protein precipitation (PPT) was developed for the selective extraction of triptorelin from plasma. The extracts were analyzed by reversed-phase liquid chromatography (RPLC). Proteins, phospholipids and highly polar interferences could be removed from plasma by the efficient combination of PPT, HILIC-SPE and RPLC-MS/MS. This method was evaluated by matrix effect, recovery and process efficiency at different concentration levels (50, 500 and 5,000 ng/mL) of triptorelin. Furthermore, the performance of HILIC-SPE was compared with that of reversed-phase C18 SPE and hydrophilic lipophilic balance (Oasis HLB) SPE. Among them, HILIC-SPE provided the minimum matrix effect (ranging from 96.02% to 103.41%), the maximum recovery (ranging from 80.68% to 90.54%) and the satisfactory process efficiency (ranging from 82.83% to 92.95%). The validated method was successfully applied to determine triptorelin in rat plasma. Copyright © 2014 Elsevier B.V. All rights reserved.
HILIC separation and quantitation of water-soluble vitamins using diol column.
Karatapanis, Andreas E; Fiamegos, Yiannis C; Stalikas, Constantine D
2009-04-01
Hydrophilic interaction liquid-chromatography (HILIC) in conjunction with diode array detection has been applied for the separation of selected-water-soluble vitamins using an end-capped HILIC-diol column. Vitamins with significant biological importance, such as thiamine (B(1)), riboflavin (B(2)), nicotinic acid (B(3)), nicotinamide (B(3)), pyridoxine (B(6)), folic acid (B(9)), cyanocobalamin (B(12)) and ascorbic acid (vitamin C) were simultaneously separated. Chromatographic conditions including type and percentage of organic modifier in the mobile phase, pH, type and concentration of buffer salt and flow rate were investigated. ACN was shown to offer superior separation for the compounds tested as compared to methanol, isopropanol and THF. Isocratic separation and analysis were achieved for six vitamins (B(1), B(2), nicotinic acid/nicotinamide, B(6) and C) at ACN-H(2)O 90:10, containing ammonium acetate 10 mM, triethylamine 20 mM, pH 5.0, using a flow rate of 0.8 mL/min, while a gradient was necessary to resolve a mixture of all eight water-soluble vitamins. The HILIC method was validated and successfully applied to the analysis of a pharmaceutical formulation and an energy drink negating the need for time consuming clean-up steps.
Right Ventricular Thrombus with Behçet's Syndrome
Dogan, Sait M.; Birdane, Alparslan; Korkmaz, Cengiz; Ata, Necmi; Timuralp, Bilgin
2007-01-01
Behçet's syndrome is a chronic multisystem disease that presents with recurrent oral and genital ulceration and recurrent uveitis. Cardiac involvement is an extremely rare manifestation of this disorder. A 33-year-old man with Behçet's syndrome was admitted to our department with a history of cough, fever, chest pain, hemoptysis, and weight loss. Transthoracic and transesophageal echocardiography revealed a right ventricular thrombus. After 1 month of treatment with warfarin, cyclophosphamide, and corticosteroid, the intracardiac thrombus resolved. PMID:17948088
Dogan, Sait M; Birdane, Alparslan; Korkmaz, Cengiz; Ata, Necmi; Timuralp, Bilgin
2007-01-01
Behçet's syndrome is a chronic multisystem disease that presents with recurrent oral and genital ulceration and recurrent uveitis. Cardiac involvement is an extremely rare manifestation of this disorder. A 33-year-old man with Behçet's syndrome was admitted to our department with a history of cough, fever, chest pain, hemoptysis, and weight loss. Transthoracic and transesophageal echocardiography revealed a right ventricular thrombus. After 1 month of treatment with warfarin, cyclophosphamide, and corticosteroid, the intracardiac thrombus resolved.
Gritti, Fabrice; Guiochon, Georges
2010-07-30
Surprisingly, the mass transfer kinetic properties of columns packed with superficially porous particles are markedly different from those of columns packed with fully porous particles. The performances of 2.1mmx150mm columns packed with a new type of sub-2microm particles, the superficially porous 1.7microm Kinetex-C(18), and with the classical 1.7microm BEH-C(18) fully porous particles were measured and are discussed. The sample was naphtho[2,3-a]pyrene; the use of different mobile phase compositions allowed a comparison between data measured with retention factors of k(') approximately 2 and k(') approximately 20. The minimum reduced height equivalent to a theoretical plate (HETP) of the two columns were similar, at h(min)=2.0. However, this minimum HETP was observed at a markedly shorter reduced linear velocity for the column packed with totally porous particles, between 5 and 7 for BEH, than for the one packed with shell particles, between 8 and 10 for Kinetex. This result is explained by the combination of (1) a 35% smaller B term for the Kinetex column than for the BEH column, due to the 37% lower porous volume of the former; (2) a larger reduced A term for the Kinetex column (1.6), showing a relatively poorly packed column with significant trans-column velocity biases than for the BEH column (ca. 1.0); and (3) a much lesser dependance of the efficiency on the mobile phase velocity at high velocities for the Kinetex than for the BEH column, when these columns are placed in the oven of the instrument under still-air conditions. The heat friction affects significantly more the efficiency of the BEH column than that of the Kinetex column. This unexpected result is accounted for by the three times smaller heat conductivity of the BEH bed (lambda(BEH) approximately 0.25 W/m/K) than that of the Kinetex bed (lambda(Kinetex) approximately 0.75W/m/K).
Wahab, M Farooq; Ibrahim, Mohammed E A; Lucy, Charles A
2013-06-18
Stationary phases for hydrophilic interaction liquid chromatography (HILIC) are predominantly based on silica and polymer supports. We present porous graphitic carbon particles with covalently attached carboxylic acid groups (carboxylate-PGC) as a new HILIC stationary phase. PGC particles were modified by adsorbing the diazonium salt of 4-aminobenzoic acid onto the PGC, followed by reduction of the adsorbed salt with sodium borohydride. The newly developed carboxylate-PGC phase exhibits different selectivity than that of 35 HPLC columns, including bare silica, zwitterionic, amine, reversed, and unmodified PGC phases. Carboxylate-PGC is stable from pH 2.0 to 12.6, yielding reproducible retention even at pH 12.6. Characterization of the new phase is presented by X-ray photoelectron spectroscopy, thermogravimetry, zeta potentials, and elemental analysis. The chromatographic performance of carboxylate-PGC as a HILIC phase is illustrated by separations of carboxylic acids, nucleotides, phenols, and amino acids.
Short-Chain Polysaccharide Analysis in Ethanol-Water Solutions.
Yan, Xun
2017-07-01
This study demonstrates that short-chain polysaccharides, or oligosaccharides, could be sufficiently separated with hydrophilic interaction LC (HILIC) conditions and quantified by evaporative light-scattering detection (ELSD). The multianalyte calibration approach improved the efficiency of calibrating the nonlinear detector response. The method allowed easy quantification of short-chain carbohydrates. Using the HILIC method, the oligosaccharide solubility and its profile in water/alcohol solutions at room temperature were able to be quantified. The results showed that the polysaccharide solubility in ethanol-water solutions decreased as ethanol content increased. The results also showed oligosaccharides to have minimal solubility in pure ethanol. In a saturated maltodextrin ethanol (80%) solution, oligosaccharide components with a degree of polymerization >12 were practically insoluble and contributed less than 0.2% to the total solute dry weight. The HILIC-ELSD method allows for the identification and quantification of low-MW carbohydrates individually and served as an alternative method to current gel permeation chromatography procedures.
Separation of carbohydrates using hydrophilic interaction liquid chromatography.
Fu, Qing; Liang, Tu; Li, Zhenyu; Xu, Xiaoyong; Ke, Yanxiong; Jin, Yu; Liang, Xinmiao
2013-09-20
A strategy was developed to rapidly evaluate chromatographic properties of hydrophilic interaction chromatography (HILIC) columns for separating carbohydrates. Seven HILIC columns (Silica, Diol, TSK Amide-80, XAmide, Click Maltose, Click β-CD, and Click TE-Cys columns) were evaluated by using three monosaccharide and seven disaccharides as probes. The influence of column temperature on the peak shape and tautomerization of carbohydrates, as well as column selectivity were investigated. The influence of surface charge property on the retention was also studied by using glucose, glucuronic acid, and glucosamine, which indicated that buffer salt concentration and pH value in mobile phase was necessary to control the ionic interactions between ionic carbohydrates and HILIC columns. According to evaluation results, the XAmide column was selected as an example to establish experimental schemes for separation of complex mixtures of oligosaccharide. Copyright © 2013 Elsevier Ltd. All rights reserved.
Behçet's syndrome: facts and controversies.
Mat, Cem; Yurdakul, Sebahattin; Sevim, Ayşegül; Özyazgan, Yılmaz; Tüzün, Yalçın
2013-01-01
Behçet's syndrome is a systemic vasculitis of small and large vessels affecting both veins and arteries. Almost all patients with Behçet's syndrome have recurrent oral aphthae, followed by genital ulcers, variable skin lesions, such as erythema nodosum and papulopustuler lesions, arthritis, uveitis, thrombophlebitis, and gastrointestinal and central nervous system involvement. Recent epidemiologic works suggest that genetic factors are more important than environmental factors in its pathogenesis. European League Against Rheumatism guidelines were recently published for the treatment of Behçet's syndrome. Although these are quite useful for the management of mucocutaneous, eye, and joint involvement, treatment of vascular, neurological, and gastrointestinal involvement are still problematic as there are no controlled studies for these manifestations. This contribution addresses the epidemiology, mucocutaneous manifestations, diagnostic criteria, and evidence-based therapies, including biologic agents. Copyright © 2013 Elsevier Inc. All rights reserved.
Chen, Huang-Chi; Chiu, Ying-Ming
2012-03-14
Behçet's disease is characterized by recurrent oral ulcers, genital ulcers, uveitis and skin lesions. Myelodysplastic syndrome (MDS) is characterized by problems due to ineffective hematopoiesis. Several studies have identified a relationship between MDS and Behçet's disease, especially intestinal Behçet's disease. Trisomy 8 seems to play an important role in these disorders as well. The present case was a 24-year-old woman who had a huge tonsil ulcer with initial symptoms of odynophagia and intermittent fever. We also noted folliculitis on her upper back. Five days later, she began to experience diarrhea and abdominal pain. Abdominal computed tomography and subsequent surgery revealed ileum perforation and enterocolitis with multiple ulcers. Later, she was admitted again for a vulvar suppurative ulcer and suspicious Bartholin's cyst infection. The patient's clinical presentations met the criteria for Behçet's disease. Six months after the bowel perforation event, we noted the development of pancytopenia in a routine laboratory examination. All the examinations led to the diagnosis of MDS with trisomy 8. The most unusual finding was that multiple large vessel thrombi developed during follow-up. Previous studies have suggested that trisomy 8 in MDS leads to concurrent intestinal Behçet's disease. Moreover, the inflammatory and immune genes related to thrombus formation are overexpressed in cases of MDS with trisomy 8. Trisomy 8 must play a role in thrombosis. Further studies are needed to help clarify the pathophysiology and pathogenesis of these disorders.
Resolution of Behçet's syndrome associated pulmonary arterial aneurysms with infliximab.
Schreiber, Benjamin E; Noor, Nadim; Juli, Christoph F; Haskard, Dorian O
2011-12-01
We describe the successful treatment of pulmonary arterial aneurysms in Behçet's syndrome using a tumor necrosis factor (TNF) inhibitor. A case is reported of Behçet's syndrome complicated by pulmonary arterial aneurysms that responded to anti-TNF therapy. This is accompanied by a literature review of previously published cases. We searched the English language medical literature using the PubMed and Medline search terms: "Behçet's," "Pulmonary aneurysms," and "infliximab," "etanercept," or "adalimumab." A 43-year-old man with a 6-month history of oral and genital ulcers, weight loss, and fatigue developed arterial aneurysms in the common carotid and common iliac arteries and thromboses in a femoral vein and pulmonary arteries. Treatment with high-dose oral corticosteroids and pulsed intravenous cyclophosphamide was initiated but while on treatment he developed pulmonary arterial aneurysms with hemoptysis. His treatment was changed to intravenous infliximab with methotrexate to which he showed a good response with marked clinical improvement, reduction in his inflammatory markers, and regression of the pulmonary arterial aneurysms. The review of the literature identified 3 reported cases of treatment of pulmonary arterial aneurysms in Behçet's syndrome with anti-TNF therapy, with good outcomes in each case. Pulmonary artery aneurysms are important complications of Behçet's syndrome. Anti-TNF inhibitors should be considered in patients who do not respond to treatment with corticosteroids and cyclophosphamide. Copyright © 2011 Elsevier Inc. All rights reserved.
Stability-indicating UPLC method for determining related substances and degradants in dronedarone.
Pydimarry, Surya Prakash Rao; Cholleti, Vijay Kumar; Vangala, Ranga Reddy
2014-08-01
A simple, sensitive and reproducible method was developed on ultra-performance liquid chromatography coupled with photodiode array detection for the quantitative determination of dronedarone hydrochloride (DRO) in drug substance and pharmaceutical dosage forms. The method is applicable for the quantification of related substances and assays of drug substances. Chromatographic separation was achieved on Acquity UPLC BEH C8 100 mm, 2.1 mm and 1.7 µm columns, using gradient elution within a short run time of 10.0 min. The eluted compounds were monitored at 288 nm, the flow rate was 0.5 mL/min and the column oven temperature was maintained at 40°C. The resolution of DRO and 11 impurities (potentials and by-products) was greater than 2.0 for all pairs of components. The high correlation coefficient value (>0.9995) indicates the clear correlations between the concentrations of investigated compound and their peak areas within the test ranges. The repeatability and intermediate precision, expressed by the relative standard deviation, were less than 2.5%. The accuracy and validity of the method were further ascertained by performing recovery studies via a spike method. The accuracy of the method, expressed as relative error, was satisfactory. No interference was observed from concomitant substances normally added to the tablets. DRO was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. DRO was found to degrade significantly in acid and base stress conditions and to remain stable in thermal, photolytic degradation, oxidative and hydrolytic conditions. The degradation products were well resolved from primary peak and its impurities, proving that the method is stability indicating. The developed method was validated as per International Conference on Harmonization guidelines with respect to specificity, limit of detection, limit of quantification, linearity, accuracy, precision, solution stability and robustness. This method is also suitable for the determination of DRO drug substance and pharmaceutical dosage forms. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ultra high pressure liquid chromatography. Column permeability and changes of the eluent properties.
Gritti, Fabrice; Guiochon, Georges
2008-04-11
The behavior of four similar liquid chromatography columns (2.1mm i.d. x 30, 50, 100, and 150 mm, all packed with fine particles, average d(p) approximately 1.7 microm, of bridged ethylsiloxane/silica hybrid-C(18), named BEH-C(18)) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of +/-0.2 degrees C in still air and +/-0.1 degrees C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144+/-3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured DeltaT=25-30 K, (Deltaeta/eta) approximately 100%, and (Deltarho/rho) approximately 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in UPLC is discussed.
Morikawa, Satoru; Ouchi, Takehito; Asoda, Seiji; Horie, Nobuyuki; Tsunoda, Kazuyuki; Kawana, Hiromasa; Nakagawa, Taneaki
2018-05-01
Behçet's disease is a systemic disorder of unknown etiology. It involves multiple organ systems and is characterized by recurring episodes of oral ulcers as well as ocular, genital, and skin lesions. Oral ulcers can affect tooth brushing and impair proper oral hygiene. As a result, a dental biofilm accumulates, and the condition of the teeth and periodontal tissue deteriorates. The aim of this case report is to highlight the efficacy of periodontal treatment for patients with Behçet's disease. A 51-year-old man with Behçet's disease presented with generalized severe periodontitis. After basic treatment of the periodontal tissues, periodontal surgery was performed at several sites with bony defects. However, the patient developed severe stomatitis in the oral mucosa and gingiva after periodontal surgery. Administration of the antimicrobial agent cefdinir had little effect on recovery; however, subsequent administration of sitafloxacin resulted in significant improvement of the stomatitis. This case demonstrates that periodontal therapy is very useful for alleviating the oral signs and symptoms of Behçet's disease. Systemic antibiotic treatment with sitafloxacin (but not cefdinir) and mechanical debridement were effective in preventing the recurrence of aphthous ulcer outbreaks after periodontal surgery.
Genetics Home Reference: Behçet disease
... of Behçet disease has been reported in northern Turkey, where the disorder affects up to 420 in ... Updated Pages Reviewed : June 2017 Published : June 19, 2018 The resources on this site should not be ...
Rituximab is effective in severe treatment-resistant neurological Behçet's syndrome.
Kidd, D P
2015-12-01
The objective of this study is to describe a case of severe and treatment-resistant neurological Behçet's syndrome responsive to a novel therapy. This case report describes the patient who failed to respond to conventional therapy but the brain stem lesion resolved with the anti-CD20 biological agent rituximab. Neurological complications are uncommon in Behçet's syndrome; 80% involve a meningoencephalitis which can be severe and relapsing. This is the first report of effectiveness of rituximab in this uncommon disease.
Chen, Mengchun; Song, Wenjie; Wang, Shuanghu; Chen, Qiulei; Pan, Peipei; Xu, Tao; Hu, Guoxin; Zheng, Zhiqiang
2016-08-01
A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for the simultaneous determination of bosentan (BOS), glimepiride (GLP), hydroxyl bosentan (HYBOS) and hydroxyl glimepiride (M1) in rat plasma using one-step protein precipitation was developed and validated. After addition of ambrisentan as an internal standard (IS), protein precipitation by acetonitrile was used in sample preparation. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm particle size, Waters Corp., Milford, MA, USA) and inline 0.2 μm stainless steel frit filter (Waters Corp.) with acetonitrile-0.1% formic acid as the mobile phase at a flow rate of 0.4 mL/min with gradient elution. The column temperature was maintained at 40°C. Only 4 min was needed for an analytical run. The retention times were ∼3.29 min for BOS, 3.56 min for GLP, 1.42 min for HYBOS, 1.53 min for M1 and 3.22 min for IS. Electrospray ionization source was employed and operated in positive-ion mode; multiple reaction monitoring mode was applied to target fragment ions m/z 552 → 202, m/z 568 → 202, m/z 491 → 352, m/z 507 → 352 and m/z 379 → 347 for BOS, HYBOS, GLP, M1 and IS, respectively. The assay was validated over concentration ranges of 25-5,000 ng/mL (r(2) = 0.9984) for BOS, 1-200 ng/mL (r(2) = 0.9999) for GLP, 0.5-100 ng/mL (r(2) = 0.9999) for HYBOS and 0.1-20 ng/mL (r(2) = 0.9984) for M1. Intra- and interday precision values for replicate quality control samples were within 14.2% for all analytes during the assay validation. Mean quality control accuracy values were within -3.3 to 14.4% of nominal values for all analytes. The mean recoveries of BOS, GLP, HYBOS, M1 and ambrisentan from the plasma exceeded 90.4%. The analytes were stable in rat plasma for at least 2 h at room temperature, 30 days at -40°C and following at least three freeze-thaw cycles (-40°C to room temperature). This method was successfully applied to a pharmacokinetic study of coadministeration of BOS and GLP in rats. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Hatemi, Ibrahim; Hatemi, Gulen; Pamuk, Omer Nuri; Erzin, Yusuf; Celik, Aykut Ferhat
2015-01-01
Gastrointestinal involvement of Behçet's syndrome is usually treated with glucocorticoids, 5-aminosalicylic acid compounds and azathioprine. However, some patients are refractory to these conventional therapy modalities. In this paper we report our experience on 13 patients with gastrointestinal involvement of Behçet's syndrome who were refractory to the conventional therapy and who were treated with TNF-alpha antagonists and/or thalidomide. We reviewed the charts of our Behçet's syndrome patients with gastrointestinal involvement and identified those who were treated with TNF-alpha antagonists and/or thalidomide. Demographic features, previous and concomitant drugs, previous surgery, time to remission and duration of remission were tabulated. We also performed a systematic review of publications on gastrointestinal involvement of Behçet's syndrome patients treated with TNF-alpha antagonists and/or thalidomide. Among our 64 patients with gastrointestinal involvement of Behçet's syndrome, we identified 13 (20%) (7 women, 6 men, mean age 27.4±9.4) who had been treated with TNF-alpha antagonists and/or thalidomide. Their previous medications were glucocorticoids (13/13), azathioprine (13/13), 5-aminosalicylic acid derivatives (3/13) and budesonide (1/13). Clinical and endoscopic remission was obtained in 10 patients. One patient died with sepsis. The systematic literature search revealed 91 cases who had used TNF-alpha antagonists and 15 who had used thalidomide. Among the patients who had received TNF-alpha antagonists, clinical remission was obtained in 47/91 patients (51%), while endoscopic remission was observed in 21/46 (45%) who had a control colonoscopy. One fifth of our Behçet's syndrome patients with gastrointestinal involvement were refractory to conventional treatment modalities. Remission was obtained with TNF-alpha antagonists and/or thalidomide in about 75% of the cases.
Role of IL-22– and TNF-α–Producing Th22 Cells in Uveitis Patients with Behçet’s Disease
Kawazoe, Yuko; Imai, Ayano; Kawaguchi, Tatsushi; Horie, Shintaro; Keino, Hiroshi; Takahashi, Masayo; Mochizuki, Manabu
2013-01-01
Behçet’s disease is a systemic inflammatory disorder with recurrent episodes of oral ulceration, skin lesions, genital ulceration, and intraocular inflammation (uveitis). The intraocular inflammation is strictly associated with Th effector cells. IL-22 is a member of the IL-10 cytokine family that is involved in inflammatory processes. Recently, Th22 cells were identified as a Th cell population that produces IL-22 and TNF-α and are distinct from Th1, Th2, and Th17 cells. In this study, we established Th22-type T cell clones from ocular samples taken from Behçet’s disease patients with active uveitis. These clones produced large amounts of IL-22 and TNF-α but not the Th1 cytokine IFN-γ and the Th17 cytokine IL-17. CD4+ T cells from the peripheral blood of Behçet’s disease patients differentiated into Th22 cells in the presence of IL-6 and TNF-α in vitro. The polarized Th22 cell lines produced large amounts of IL-22, and the polarized Th1 and Th17 cells also produced IL-22. In the presence of anti–TNF-α– and anti–IL-6–blocking Abs, Behçet’s disease Th22-type T cells failed to produce IL-22. In addition, infliximab-pretreated Th22 cells and Th22-type ocular T cells produced less IL-22 and TNF-α. Moreover, IL-22–producing T cells were isolated from mice with experimental autoimmune uveitis, an animal model of Behçet’s disease, and the intraocular T cells from uveitis models produced large amounts of IL-22 in the presence of retinal Ags. Our results suggest that inflammatory cytokines IL-22 and TNF-α may play a key role in the ocular immune response in Behçet’s disease. PMID:23630362
Ouyang, Yilan; Wu, Chengling; Sun, Xue; Liu, Jianfen; Linhardt, Robert J; Zhang, Zhenqing
2016-01-30
Heparin and low molecular weight heparin (LMWH) are widely used as clinical anticoagulants. The determination of their composition and structural heterogeneity still challenges analysts. Disaccharide compositional analysis, utilizing heparinase-catalyzed depolymerization, is one of the most important ways to evaluate the sequence, structural composition and quality of heparin and LMWH. Hydrophilic interaction chromatography coupled with quadruple time-of-flight mass spectrometry (HILIC/QTOFMS) has been developed to analyze the resulting digestion products. HILIC shows good resolution and excellent MS compatibility. Digestion products of heparin and LMWHs afforded up to 16 compounds that were separated using HILIC and analyzed semi-quantitatively. These included eight common disaccharides, two disaccharides derived from chain termini, three 3-O-sulfo-group-containing tetrasaccharides, along with three linkage region tetrasaccharides and their derivatives. Structures of these digestion products were confirmed by mass spectral analysis. The disaccharide compositions of a heparin, two batches of the LMWH, enoxaparin, and two batches of the LMWH, nadroparin, were compared. In addition to identifying disaccharides, 3-O-sulfo-group-containing tetrasaccharides, linkage region tetrasaccharides were observed having slightly different compositions and contents in these heparin products suggesting that they had been prepared using different starting materials or production processes. Thus, compositional analysis using HILIC/QTOFMS offers a unique insight into different heparin products. Copyright © 2015 John Wiley & Sons, Ltd.
Singh, Rashmi; Trivedi, Priyanka; Bawankule, Dnyaneshwar Umrao; Ahmad, Ateeque; Shanker, Karuna
2012-05-07
Evening primrose (Oenothera biennis L.) is a wild medicinal herb of Central American origin that is now globally widespread. Its traditional uses include treatment of rheumatoid arthritis and premenopausal pain both of which have an inflammatory component. The present study demonstrates the in vitro anti-inflammatory activity of three Oenothera biennis compounds. Oenotheralanosterol A and B (Oen-A & Oen-B) along with gallic acid (GA) were isolated and characterized using column chromatography and NMR. The compounds were tested with LPS stimulated peritoneal mouse macrophages assaying for suppression of IL-6, TNF-α and NO synthesis. An HILIC method for the simultaneous quantitation of GA, Oen-A, and Oen-B in Oenothera biennis plant material was also developed as a means of monitoring quality of plant material. Significant inhibition of TNF-α and IL-6 by GA, Oen-A and Oen-B was observed (p<0.05). Inhibition was concentration dependent and no synergistic or antagonistic effect on pro-inflammatory cytokines was found when used in combination (1:1) (p>0.05). The HILIC analysis method was validated using Oenothera biennis root. The study demonstrates the anti-inflammatory activity of Oenothera biennis root compounds and supports its traditional use in arthritis management. Active anti-inflammatory compounds were identified and quantified by the HILIC method. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Association of myasthenia gravis and Behçet's disease: A case report.
Kisabay, Aysin; Sari, Ummu Serpil; Boyaci, Recep; Batum, Melike; Yilmaz, Hikmet; Selcuki, Deniz
2016-01-01
Myasthenia gravis is a disease of neuromuscular junction due to auto-immune destruction of the acetylcholine receptors. Behçet's disease, on the other hand, is a multisystemic vascular-inflammatory disease. Both conditions are not common in the general population although their association has not been reported in the literature. We wanted to present our patient who developed clinical course of myasthenia gravis following discontinuation of medications due to complications of corticosteroid for Behçet's disease. It was observed that clinical findings of myasthenia gravis recovered following restarting steroid treatment and he did not experience attacks of both conditions. Although Myasthenia gravis and Behçet's disease are distinct entities clinically as well as in terms of pathogenesis, they share common physiopathological features and their treatment is based on their common features. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
Endo, Masatsugu; Sekikawa, Akira; Tsumura, Takehiko; Maruo, Takanori; Osaki, Yukio
2015-11-21
BACKGROUND Intestinal Behçet's disease-like symptoms are rare complications of myelodysplastic syndrome and are often refractory to immunosuppressive therapies. We described a case of myelodysplastic syndrome complicated by Behçet's disease-like symptoms treated with prednisolone and azacitidine. CASE REPORT A 68-year-old Japanese woman was admitted to our hospital because of persistent high fever and lower abdominal pain. Oral ulcerations developed after admission, and multiple ulcers were found in her terminal ileum by endoscopic examination. She was diagnosed with myelodysplastic syndrome with trisomy 8 by bone marrow examination. Her symptoms diminished after administration of prednisolone, but relapsed afterwards. She began azacitidine therapy and her symptoms have been controlled for at least 10 months. CONCLUSIONS This case might suggest the possibility of azacitidine as a treatment option for myelodysplastic syndrome complicated by Behçet's disease-like symptoms.
Bir, Levent Sinan; Özdemir Eşmeli, Fatma; Cenikli, Utku; Erdoğan, Çağgdaş; Değirmenci, Eylem
2007-01-01
Case report: A 25-year-old man with Behçet's disease was admitted because of weakness of the lower limbs and difficulty in urination. He had received a rabies vaccination 2 months previous because he had been bitten by a dog. Findings: Clinical and laboratory findings supported acute transverse myelitis. A hyperintense lesion and expansion at the level of conus medullaris was detected on spinal magnetic resonance imaging. Conclusion: Although neurologic involvement is one of the main causes of mortality and morbidity in Behçet's disease, the factors that aggravate the involvement of the nervous system are still unclear. Vaccination may have been the factor that had activated autoimmune mechanisms in this case. To our knowledge, involvement of the conus medullaris in Behçet's disease after rabies vaccination has not been reported. PMID:17684898
Endovascular aneurysm exclusion along a femorodistal venous bypass in active Behçet's disease.
Gretener, Silvia B; Do, Dai-Do; Baumgartner, Iris; Dinkel, Hans-Peter; Schmidli, Jürg; Birrer, Manuela
2002-10-01
To report the endovascular repair of dual aneurysms along a femorodistal venous bypass graft in a patient with Behçet's disease. A 55-year-old man of middle European ancestry with Behçet's disease had dual aneurysms evolve along the proximal segment of a femorodistal venous bypass that had been implanted 2.5 years earlier for recurrent false aneurysm formation. Owing to the lack of suitable venous conduits and the active nature of the disease, the aneurysms were successfully excluded with overlapping Hemobahn and Jostent endografts; the immunosuppressive therapy was intensified. Rupture of the aneurysms was successfully prevented, but the stent-grafts thrombosed 6 weeks later owing to exacerbation of the underlying disease. Endovascular exclusion of aneurysm in venous bypass grafts in Behçet's disease is feasible. Although the stent-grafts thrombosed, they did prevent rupture of the aneurysms.
Görgens, Christian; Guddat, Sven; Orlovius, Anne-Katrin; Sigmund, Gerd; Thomas, Andreas; Thevis, Mario; Schänzer, Wilhelm
2015-07-01
In the field of LC-MS, reversed phase liquid chromatography is the predominant method of choice for the separation of prohibited substances from various classes in sports drug testing. However, highly polar and charged compounds still represent a challenging task in liquid chromatography due to their difficult chromatographic behavior using reversed phase materials. A very promising approach for the separation of hydrophilic compounds is hydrophilic interaction liquid chromatography (HILIC). Despite its great potential and versatile advantages for the separation of highly polar compounds, HILIC is up to now not very common in doping analysis, although most manufacturers offer a variety of HILIC columns in their portfolio. In this study, a novel multi-target approach based on HILIC high resolution/high accuracy mass spectrometry is presented to screen for various polar stimulants, stimulant sulfo-conjugates, glycerol, AICAR, ethyl glucuronide, morphine-3-glucuronide, and myo-inositol trispyrophosphate after direct injection of diluted urine specimens. The usage of an effective online sample cleanup and a zwitterionic HILIC analytical column in combination with a new generation Hybrid Quadrupol-Orbitrap® mass spectrometer enabled the detection of highly polar analytes without any time-consuming hydrolysis or further purification steps, far below the required detection limits. The methodology was fully validated for qualitative and quantitative (AICAR, glycerol) purposes considering the parameters specificity; robustness (rRT < 2.0%); linearity (R > 0.99); intra- and inter-day precision at low, medium, and high concentration levels (CV < 20%); limit of detection (stimulants and stimulant sulfo-conjugates < 10 ng/mL; norfenefrine; octopamine < 30 ng/mL; AICAR < 10 ng/mL; glycerol 100 μg/mL; ETG < 100 ng/mL); accuracy (AICAR 103.8-105.5%, glycerol 85.1-98.3% at three concentration levels) and ion suppression/enhancement effects.
Behçet disease and protein-losing enteropathy due to intestinal lymphangiectasia.
Rodríguez-Muguruza, Samantha; Caballero, Noemí; Horneros, Judith; Domenech, Eugeni; Mateo, Lourdes
2015-01-01
We report an unusual case of a patient with Behçet's disease that developed protein-losing enteropathy due to intestinal lymphangiectasia. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.
Pandey, Renu; Chandra, Preeti; Arya, Kamal Ram; Kumar, Brijesh
2014-12-01
A rapid and sensitive ultra high performance liquid chromatography electrospray ionization tandem mass spectrometry method was developed and validated for the simultaneous determination of 13 flavonoids in leaf, stem, and fruit extracts of male and female trees of Ginkgo biloba to investigate gender- and age-related variations of flavonoids content. Chromatographic separation was accomplished on an Acquity UPLC BEH C18 column (50 mm × 2.1 mm id, 1.7 μm) in 5 min. Quantitation was performed using negative electrospray ionization mass spectrometry in multiple reaction monitoring mode. The calibration curves of all analytes showed a good linear relationship (r(2) ≥ 0.9977) over the concentration range of 1-1000 ng/mL. The precision evaluated by an intra- and interday study showed RSD ≤ 1.98% and good accuracy with overall recovery in the range from 97.90 to 101.09% (RSD ≤ 1.67%) for all analytes. The method sensitivity expressed as the limit of quantitation was typically 0.25-3.57 ng/mL. The results showed that the total content of 13 flavonoids was higher in the leaf extract of an old male Ginkgo tree compared to young female Ginkgo trees. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Junnotula, Venkatraman; Licea-Perez, Hermes
2013-05-01
A simple, selective, and sensitive quantitative method has been developed for the simultaneous determination of levodopa and carbidopa in rat and monkey plasma by protein precipitation using acetonitrile containing the derivatizing reagent, flourescamine. Derivatized products of levodopa and carbidopa were separated on a BEH C18 column (2.1 mm × 50 mm; 1.7 μm particle size) using ultra high performance liquid chromatography (UHPLC) without any further purification. Tandem mass spectrometry (MS/MS) was used for detection. The method was validated over the concentration range of 5-5000 ng/mL and 3-3000 ng/mL for levodopa and carbidopa, respectively in rat and monkey plasma. Due to the poor stability of the investigated analytes in biological matrices, a mixture of sodium metabisulfite and hydrazine dihydrochloride was used as a stabilizer. This method was successfully utilized to support pharmacokinetic studies in both species. The results from assay validations and incurred samples re-analysis show that the method is selective, sensitive and robust. To our knowledge, this is the first UHPLC-MS/MS based method that utilizes derivatization with fluorescamine and provides adequate sensitivity for both levodopa and carbidopa with 50 μL of sample and a run time of 3.5 min. Copyright © 2013 Elsevier B.V. All rights reserved.
Diagnostic dilemma: Intracardiac mass in a woman with Behçet's syndrome.
Núñez-Cabarcas, Edilberto; López-Ruiz, Nilson; Ramírez-Rincón, Alex
2014-01-01
Intracardiac thrombosis is a rare manifestation of cardiac involvement in Behçet's disease, and it may be mistaken for a heart tumor. In this letter we present the case of a patient diagnosed with Behçet's disease who was incidentally found to have a mass in the right atrium suspicious of a cardiac tumor. Nevertheless, cardiac magnetic resonance showed a cardiac thrombus. Immunosuppressive therapy and anticoagulation were effective for thrombus resolution. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.
Transcatheter embolization of renal artery aneurysm in Behçet's disease.
Planer, D; Verstandig, A; Chajek-Shaul, T
2001-01-01
A 20-year-old man with Behçet's disease presented with a ruptured renal artery aneurysm. This patient had previously had aneurysms of the coronary arteries and coronary vein thrombosis that were treated with immunosuppression. A selective transcatheter embolization of the renal artery branch was done successfully and treatment with corticosteroids and methotrexate was added. Presented here is a rare complication of Behçet's disease, with discussion on the pathophysiology, differential diagnosis, and the advantages and disadvantages of the angiographic treatment. This paper is supplemented with a comprehensive review of the literature.
Protracted fever of unknown origin as the presenting symptom of Behçet's disease. Report of a case.
Niamane, Radouane; Karim Moudden, Mohamed; Zyani, Mahamed; Hda, Ali
2005-03-01
We report a case of Behçet's disease that presented as protracted fever of unknown origin. The diagnosis was established when a thromboembolic event and ora3l aphthous ulcers occurred simultaneously. Antibiotics had no effect on the fever, which resolved when glucocorticoid and anticoagulant therapy was given. Among causes of protracted fever of unknown origin, Behçet's disease is exceedingly rare but should be considered together with the other vasculitides. Above all, the presence of a fever should prompt a search for a thromboembolic complication.
Knudsen, Gabriel A; Hughes, Michael F; Sanders, J Michael; Hall, Samantha M; Birnbaum, Linda S
2016-11-15
2-Ethylhexyl-2,3,4,5-tetrabromobenzoate (EH-TBB) and bis(2-ethylhexyl)tetrabromophthalate (BEH-TEBP) are novel brominated flame retardants used in consumer products. A parallelogram approach was used to predict human dermal absorption and flux for EH-TBB and BEH-TEBP. [ 14 C]-EH-TBB or [ 14 C]-BEH-TEBP was applied to human or rat skin at 100nmol/cm 2 using a flow-through system. Intact rats received analogous dermal doses. Treated skin was washed and tape-stripped to remove "unabsorbed" [ 14 C]-radioactivity after continuous exposure (24h). "Absorbed" was quantified using dermally retained [ 14 C]-radioactivity; "penetrated" was calculated based on [ 14 C]-radioactivity in media (in vitro) or excreta+tissues (in vivo). Human skin absorbed EH-TBB (24±1%) while 0.2±0.1% penetrated skin. Rat skin absorbed more (51±10%) and was more permeable (2±0.5%) to EH-TBB in vitro; maximal EH-TBB flux was 11±7 and 102±24pmol-eq/cm 2 /h for human and rat skin, respectively. In vivo, 27±5% was absorbed and 13% reached systemic circulation after 24h (maximum flux was 464±65pmol-eq/cm 2 /h). BEH-TEBP in vitro penetrance was minimal (<0.01%) for rat or human skin. BEH-TEBP absorption was 12±11% for human skin and 41±3% for rat skin. In vivo, total absorption was 27±9%; 1.2% reached systemic circulation. In vitro maximal BEH-TEBP flux was 0.3±0.2 and 1±0.3pmol-eq/cm 2 /h for human and rat skin; in vivo maximum flux for rat skin was 16±7pmol-eq/cm 2 /h. EH-TBB was metabolized in rat and human skin to tetrabromobenzoic acid. BEH-TEBP-derived [ 14 C]-radioactivity in the perfusion media could not be characterized. <1% of the dose of EH-TBB and BEH-TEHP is estimated to reach the systemic circulation following human dermal exposure under the conditions tested. 2-Ethylhexyl 2,3,4,5-tetrabromobenzoate (PubChem CID: 71316600; CAS No. 183658-27-7 FW: 549.92g/mol logP est : 7.73-8.75 (12)) Abdallah et al., 2015a. Other published abbreviations for 2-ethylhexyl-2,3,4,5-tetrabromobenzoate are TBB EHTeBB or EHTBB Abdallah and Harrad, 2011. bis(2-ethylhexyl) tetrabromophthalate (PubChem CID: 117291; CAS No. 26040-51-7 FW: 706.14g/mol logP est : 9.48-11.95 (12)). Other published abbreviations for bis(2-ethylhexyl)tetrabromophthalate are TeBrDEPH TBPH or BEHTBP. Published by Elsevier Inc.
Purves, Randy W; Khazaei, Hamid; Vandenberg, Albert
2018-02-01
Faba bean (Vicia faba L.) provides environmental and health benefits; however, the presence of the pyrimidine glycosides vicine and convicine (v-c) in its seeds limits consumption. Low v-c genotypes have been introduced, but the convicine levels in these genotypes have not been quantified. To improve detection, the polar nature of v-c was exploited by implementing hydrophilic interaction liquid chromatography (HILIC). A sample preparation method using a two-step extraction was developed for use with UV and/or tandem mass spectrometry (SRM) detection. The HILIC-UV method was suitable for over three orders of magnitude, covering the range of v-c concentrations in faba bean seeds across all genotypes tested. The linear range of HILIC-SRM was slightly less (∼3 orders of magnitude), but improved sensitivity and selectivity make it more suitable for quantifying low v-c samples. The analysis of 13 genotypes suggests that v-c concentrations in faba bean seeds may be independent quantitative traits. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sun, Yongming; Xia, Biqi; Chen, Xiangzhun; Duanmu, Chuansong; Li, Denghao; Han, Chao
2015-01-01
The identification and quantification of four anthocyanins (cyanidin-3-O-glucoside, peonidin-3-O-glucoside, delphinidin-3-O-glucoside, and malvidin-3-O-glucoside) in red grape wine were carried out by hydrophilic interaction liquid chromatography/triple quadrupole linear ion trap MS (HILIC/QTrap-MS/MS). Samples were diluted directly and separated on a Merck ZIC HILIC column with 20 mM ammonium acetate solution-acetonitrile mobile phase. Quantitative data acquisition was carried out in the multiple reaction monitoring mode. Additional identification and confirmation of target compounds were performed using the enhanced product ion mode of the linear ion trap. The LOQs were in the range 0.05-1.0 ng/mL. The average recoveries were in the range 94.6 to 104.5%. The HILIC/QTrap-MS/MS platform offers the best sensitivity and specificity for characterization and quantitative determination of the four anthocyanins in red grape wines and fulfills the quality criteria for routine laboratory application.
Behçet's disease in the United States: A single center descriptive and comparative study.
Kilian, Nathan C; Sawalha, Amr H
2017-12-01
Behçet's disease is heterogeneous with clinical variability across ethnicities and geographic locations. The goal of this study was to analyze the clinical characteristics of our multi-ethnic Behçet's disease cohort at the University of Michigan. A detailed patient characterization was performed. Differences in disease characteristics between men and women, and between patients fulfilling the International Criteria for Behçet's Disease (ICBD) and the International Study Group criteria (ISG) were determined in our cohort. A total of 114 patients with a male to female ratio of ~ 1:4 were included. All patients met the ICBD criteria, including 76 who also met the ISG criteria. Over 95% of patients had recurrent genital ulcers, which is higher than generally reported. Retinitis was 5.3 times more likely in men than in women (p=0.009), and arthralgia was 3.3 times more likely in women than men (p=0.048). When comparing cohorts derived from the two different criteria, the ISG cohort had more skin manifestations (OR=3.3, p=0.0006). Acneiform lesions were associated with ~8 times higher odds of developing retinitis in our patients (p=0.0008), and superficial thrombophlebitis was associated with a trend for higher odds of developing uveitis (OR=4.1, p=0.057). Using the ICBD criteria, 38 additional patients were identified compared to only using the ISG criteria. Of these patients, 28 presented with only mucosal ulceration with or without joint involvement. We characterize Behçet's disease in a multi-ethnic cohort from North America. Using ICBD criteria in the United States significantly increases the likelihood of identifying Behçet's disease, particularly in patients with isolated mucosal involvement who constitute a substantial subset of patients in this region.
Zheng, Xiaobo; Xu, Fuchao; Luo, Xiaojun; Mai, Bixian; Covaci, Adrian
2016-05-01
Phosphate flame retardants (PFRs) and novel brominated flame retardants (NBFRs) (2-ethylhexyl-2,3,4,5-tetrabromo-benzoate (EH-TBB) and bis-(2-ethylhexyl)-3,4,5,6-tetrabromo-phthalate (BEH-TEBP)) were measured in free-range chicken eggs from three e-waste recycling sites and a negative control site located in Guangdong province, Southern China. BEH-TEBP, tris-(chloroethyl)-phosphate (TCEP), tris-(chloropropyl)-phosphate (∑TCPP, two isomers) and tris-(1,3-dichloroisopropyl)-phosphate (TDCIPP) were detected in more than 50% of eggs samples with low concentrations. The median values of BEH-TEBP and total PFRs were 0.17-0.46 ng/g ww (wet weight) and 1.62-2.59 ng/g ww in eggs from the e-waste sites, respectively. The results indicate that EH-TBB, BEH-TEBP and PFRs are less persistent and bioaccumulative than polybrominated diphenyl ethers (PBDEs) in chicken eggs, and possibly also in other bio-matrices. Triphenyl phosphate (TPHP) were identified in albumen with higher frequencies, but at similar concentrations compared to yolk, while BEH-TEBP was mainly detected in yolk. The estimated daily intake (EDI) of BEH-TEBP and total PFRs from consumption of chicken eggs ranged from 0.03 to 0.09 and 0.32-0.52 ng/kg bw/day for adults, and 0.20-0.54 and 1.89-3.02 ng/kg bw/day for children in e-waste sites, respectively. Indoor dust ingestion seems to be a more important pathway for the intake of these FRs, while egg consumption is probably a more important exposure pathway for PBDEs. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kim, Sang Jin; Lee, Seungbok; Park, Changho; Seo, Jeong-Sun; Kim, Jong-Il; Yu, Hyeong Gon
2013-10-18
Behçet's disease (BD) is a chronic systemic inflammatory disorder characterized by four major manifestations: recurrent uveitis, oral and genital ulcers and skin lesions. To identify some pathogenic variants associated with severe Behçet's uveitis, we used targeted and massively parallel sequencing methods to explore the genetic diversity of target regions. A solution-based target enrichment kit was designed to capture whole-exonic regions of 132 candidate genes. Using a multiplexing strategy, 32 samples from patients with a severe type of Behçet's uveitis were sequenced with a Genome Analyzer IIx. We compared the frequency of each variant with that of 59 normal Korean controls, and selected five rare and eight common single-nucleotide variants as the candidates for a replication study. The selected variants were genotyped in 61 cases and 320 controls and, as a result, two rare and seven common variants showed significant associations with severe Behçet's uveitis (P<0.05). Some of these, including rs199955684 in KIR3DL3, rs1801133 in MTHFR, rs1051790 in MICA and rs1051456 in KIR2DL4, were predicted to be damaging by either the PolyPhen-2 or SIFT prediction program. Variants on FCGR3A (rs396991) and ICAM1 (rs5498) have been previously reported as susceptibility loci of this disease, and those on IFNAR1, MTFHR and MICA also replicated the previous reports at the gene level. The KIR3DL3 and KIR2DL4 genes are novel susceptibility genes that have not been reported in association with BD. In conclusion, this study showed that target enrichment and next-generation sequencing technologies can provide valuable information on the genetic predisposition for Behçet's uveitis.
Pecher, Daniel; Dokupilová, Svetlana; Zelinková, Zuzana; Peppelenbosch, Maikel; Mikušová, Veronika; Mikuš, Peter
2017-08-05
Thiopurine S-methyltransferase (TPMT) plays an important role in the metabolism of thiopurines used in the therapy of inflammatory bowel diseases (IBD). In this work a new progressive method for the determination of TPMT activity in red blood cells lysates was developed. Analysis was carried out by means of hydrophilic interaction liquid chromatography (HILIC) hyphenated with mass spectrometry (MS). In comparison with reversed-phase high-performance liquid chromatography (RP-HPLC), that has been typically applied in determination of TPMT activity, the HILIC significantly improved the analytical signal provided by MS, shortened analysis time, and improved chromatographic resolution. The HILIC-HPLC-MS method was optimized and validated, providing favorable parameters of detection and quantitation limits (5.5 and 16.5pmol/mL, respectively), linearity (coefficient of determination 0.9999 in the range of 0.01-1.0nmol/mL), recovery and precision (93.25-100.37% with RSD 1.06-1.32% in the whole concentration range of QC samples). Moreover, in contrast to the conventional RP-HPLC-UV approach, the complex phenotype TPMT profiles can be reliably and without interferences monitored using the HILIC-HPLC-MS method. Such advanced monitoring can provide valuable detail information on the thiopurines (e.g. evaluating ratio of methylated and non-methylated 6-mercaptopurine) and, by that, TPMT action in biological systems before and during the therapy of IBD. Copyright © 2017 Elsevier B.V. All rights reserved.
Silina, Yuliya E; Welck, Jennifer; Kraegeloh, Annette; Koch, Marcus; Fink-Straube, Claudia
2016-09-01
This paper reports a rapid HILIC-ESI-MS assay to quantify dipalmitoylphosphatidylcholine (DPPC) as component of lung surfactant for nanosafety studies. The technique was used to investigate the concentration-dependent sorption of DPPC to two-sizes of amorphous SiO2 nanoparticles (SiO2-NPs) in a MeOH:H2O (50/50v/v) mixture and in cell culture medium. In MeOH:H2O (50/50v/v), the sorption of DPPC was positively correlated with the nanoparticles concentration. A substantial affinity of small amorphous SiO2-NPs (25nm) to DPPC standard solution compared to bigger SiO2-NPs (75nm) was not confirmed for biological specimens. After dispersion of SiO2-NPs in DPPC containing cell culture medium, the capacity of the SiO2-NPs to bind DPPC was reduced in comparison to a mixture of MeOH:H2O (50/50v/v) regardless from the nanoparticles size. Furthermore, HILIC-ESI-MS revealed that A549 cells internalized DPPC during growth in serum containing medium complemented with DPPC. This finding was in a good agreement with the potential of alveolar type II cells to recycle surfactant components. Binding of lipids present in the cell culture medium to amorphous SiO2-NPs was supported by means of HILIC-ESI-MS, TEM and ICP-MS independently. Copyright © 2016 Elsevier B.V. All rights reserved.
Behçet syndrome: a contemporary view.
Yazici, Hasan; Seyahi, Emire; Hatemi, Gulen; Yazici, Yusuf
2018-02-01
The presence of symptom clusters, regional differences in disease expression and similarities with, for example, Crohn's disease suggest multiple pathological pathways are involved in Behçet syndrome. These features also make formulating disease criteria difficult. Genetic studies have identified HLA-B*51 to be the important genetic risk factor. However, the low prevalence of HLA-B*51 in many patients with bone fide disease, especially in non-endemic regions, suggests other factors must also be operative in Behçet syndrome. This consideration is also true for the newly proposed 'MHC-I-opathy' concept. Despite lacking a clear aetiological mechanism and definition, management of manifestations that include major vascular disease (such as Budd-Chiari syndrome and pulmonary artery involvement), eye disease and central nervous system involvement has improved with the help of new technology. Furthermore, even with our incomplete understanding of disease mechanisms, the prognoses of patients with Behçet syndrome, including those with eye disease, continue to improve.
Fractalkine (CX3CL1) levels in patients with Behçet's disease and neuro-Behçet's disease.
Ceyla, Irkec; Tuba, Teksut Kuz; Adisen, Esra; Esra, Adisen; Banu, Ozturk; Isil, Fidan; Ali, Gurer M; Turgut, Imir; Banu, Bozkurt
2012-04-15
The aim of the present study was to assess the role of CX3CL1 in patients with active and inactive Behçet's Disease (BD), Neuro-Behçet's Disease (NBD) and control subjects. Fifty-six patients admitted to the BD and NBD Outpatient Clinics, and 30 healthy controls were enrolled in the study. Serum CX3CL1 levels were measured by an enzyme linked immunosorbent assay (ELISA). No significant difference was found between the serum CX3CL1 levels of control subjects, and patients with active and inactive BD or NBD, regardless of treatment. To our knowledge, this is the first study analyzing CX3CL1 levels in patients with BD and NBD. Our results demonstrated that serum CX3CL1 levels were not changed in active and inactive BD and NBD. However, further large-scale studies are needed to confirm our results. Copyright © 2011 Elsevier B.V. All rights reserved.
Life story of Dr. Hulusi Behçet.
Saylan, T
1997-12-01
Dr. Hulusi Behçet was born on February 20, 1889 in Istanbul. He graduated from Gülhane Military Medical Academy in 1910 and then he specialized in Dermatology and Venereal Diseases. He served in the Edirne Military Hospital between 1914-1918 and then went to Budapest and Berlin to improve his knowledge. In 1923, he started at the Istanbul Medical Faculty as an academic staff and with university reform in 1933, he was appointed as a professor to Department of Dermatology and Venereal Diseases and continued his career there until his death in 1948. Three patients whom he had consulted for years and who shared similar symptoms made him suspect a new disease and a viral etiology which may play a role in the appearance of this disease. After several discussions and publications, medical literature had accepted Behçet's Disease as a special entity. Dr. Behçet published a total of 196 articles, 53 of which were published in prestigious international journals.
Ghosh, Partha S; Ghosh, Debabrata
2011-10-01
Benign external hydrocephalus (BEH) is considered a self-limiting condition in infants. Subdural hematoma (SDH) in infants without a history of trauma indicates nonaccidental injury (NAI). The authors studied whether SDH can complicate BEH without apparent trauma. Out of 45 children younger than 3 years with nontraumatic SDH, 9 (7 boys) with mean age 6 months had BEH as risk factor. Symptoms included increasing head size (8), fussiness, and irritability (3). Three had up-gaze restriction, 1 axial hypotonia, and 6 normal examination. Neuroimaging showed prominent extra-axial spaces; SDH was bilateral (6), subacute (5). Other etiological workup for SDH was negative except NAI in 1. Two required evacuation of SDH and subdural-peritoneal shunt; others managed conservatively. Development was normal in 8 on follow-up. On follow-up imaging of 8, SDH completely resolved in 3, markedly reduced in 3, and remained stable in 2. BEH is a risk factor for SDH in infants, thus not always benign.
Evaluation of cochlear involvement by distortion product otoacoustic emission in Behçet's disease.
Dagli, Muharrem; Eryilmaz, Adil; Tanrikulu, Salih; Aydin, Acar; Gonul, Muzeyyen; Gul, Ulker; Gocer, Celil
2008-09-01
The aim of this study was to investigate cochlear involvement in patients with Behçet's disease. Twenty-six Behçet's disease patients (52 ears) and 24 sex and age-matched healthy control subjects (48 ears) were included in the study. Pure-tone audiometry at frequencies 250, 500, 1000, 2000, 4000, 6000 Hz, immittance measures including tympanometry and acoustic reflex testing and DPOAE (distortion product otoacoustic emission) testing were performed in the patients and controls. A sensorineural hearing loss was found in eight patients (30.7%) as it was bilateral in five and unilateral in three patients. Although no typical audiometric configuration was found, one patient had a flat type audiogram, and the others had a high frequency hearing loss. The DPOAE responses of the patients and controls were significantly different in all frequencies (p<0.05). These results indicate that cochlea is affected by damage of outer hair cells in Behçet's disease.
Elbes, Delphine; Denost, Quentin; Robert, Benjamin; Köhler, Max O; Tanter, Mickaël; Bruno, Quesson
2014-05-01
Bubble-enhanced heating (BEH) may be exploited to improve the heating efficiency of high-intensity focused ultrasound in liver and to protect tissues located beyond the focal point. The objectives of this study, performed in ex vivo pig liver, were (i) to develop a method to determine the acoustic power threshold for induction of BEH from displacement images measured by magnetic resonance acoustic radiation force imaging (MR-ARFI), and (ii) to compare temperature distribution with MR thermometry for HIFU protocols with and without BEH. The acoustic threshold for generation of BEH was determined in ex vivo pig liver from MR-ARFI calibration curves of local tissue displacement resulting from sonication at different powers. Temperature distributions (MR thermometry) resulting from "conventional" sonications (20 W, 30 s) were compared with those from "composite" sonications performed at identical parameters, but after a HIFU burst pulse (0.5 s, acoustic power over the threshold for induction of BEH). Displacement images (MR-ARFI) were acquired between sonications to measure potential modifications of local tissue displacement associated with modifications of tissue acoustic characteristics induced by the burst HIFU pulse. The acoustic threshold for induction of BEH corresponded to a displacement amplitude of approximately 50 μm in ex vivo liver. The displacement and temperature images of the composite group exhibited a nearly spherical pattern, shifted approximately 4 mm toward the transducer, in contrast to elliptical shapes centered on the natural focal position for the conventional group. The gains in maximum temperature and displacement values were 1.5 and 2, and the full widths at half-maximum of the displacement data were 1.7 and 2.2 times larger than in the conventional group in directions perpendicular to ultrasound propagation axes. Combination of MR-ARFI and MR thermometry for calibration and exploitation of BEH appears to increase the efficiency and safety of HIFU treatment. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
[Diagnosis and surgical treatment results of angio-Behçet syndrome: an analysis of 26 patients].
Shen, Chen-yang; He, Chang-shun; Pan, Hao; Zhang, Xiao-ming
2012-03-01
To analyze the diagnosis and surgical treatment results of angio-Behçet syndrome. The clinical data of pre-operation diagnosis, surgical treatment methods and prospective efficacy of 26 patients who were diagnosed as Behçet syndrome between January 2003 and April 2011 was analyzed retrospectively. There were 23 male and 3 female patients, aging from 20 to 76 years with a mean of (37 ± 6) years. Among them, 3 patients showed the clinical symptoms as arterial stenosis or occlusion, 9 patients had aneurysm, 13 patients had phlebitis or phlebothrombosis. One patient had both aneurysm and venous thrombosis. Totally 11 patients had experienced 22 cases surgical treatment including interventional therapy for 8 cases, open operation for 13 cases and hybrid operation for 1 case. Twenty-two patients (84.6%) were followed up from 3 months to 96 months after various surgical treatment methods. The average follow-up periond was 39.3 months. Totally, perioperative mortality was 1/11 after surgical treatment. Healing rates were 7/8 and 8/13, recurrence rates were 5/8 and 7/8 in patients with interventional therapy compared with that of experiencing open surgery respectively. Behçet syndrome patients combined with various vascular lesions should be thought of angio-Behçet syndrome. Choosing correct surgical treatment according to patient's condition and timing of pathological changes are the keys of gaining satisfactory results.
Turkstra, F; van Vugt, R M; Dijkmans, B A C; Yazici, Y; Yazici, H
2012-01-01
To determine the preferred treatment for patients with Behçet's syndrome. A questionnaire was given to all participants of the 2010 meeting of the International Society for Behçet's Disease. Forty-one respondents from 6 different subspecialties. In the case of a patient with (severe) posterior uveitis or parenchymal central nervous system (CNS) disease no consensus was seen. A diffuse spectrum of different schedules were given. In both uveitis and CNS disease the majority of respondents preferred treatment options consisting of combination systemic therapy and systemic corticosteroids. TNF was preferred as first line drug in uveitis in 7.5% and in severe uveitis in 32.5% of respondents. In parenchymal CNS disease TNF blockage was given by 17% of the respondents. EULAR guidelines regarding uveitis were followed by 12/40 physicians. In patients with a new deep vein thrombosis, 90% of respondents would intensify immunosuppression. More than half would also anticoagulate. Although consensus about how to treat patients with Behçet syndrome in different clinical situations is far from present, treatment has become more intensive when compared to 10-20 years ago. More uniformity should be sought for in the decision process in individual patients with Behçet's syndrome, regarding their treatment, as well as adhering to evidence, as presented in the EULAR guidelines, when present.
Behçet's syndrome in Iranian Azari people.
Shahneh, Fatemeh Zare; Babaloo, Zohreh; Baradaran, Behzad; Hamzavi, Fatemeh; Bayazi, Babak; Bandehagh, Ali
2012-11-01
Behçet's Syndrome (BS) is a chronic recurrent multisystemic inflammatory disorder characterized by oral and genital ulcers, ocular inflammation. Behçet's syndrome has a complex genetic etiology. However, epidemiological studies recommend that genetic factors have a significant influence to its pathogenesis, alike to other autoinflammatory disorders. Epidemiological statistics, clinical records and HLA typing were studied in Iranian Azari patients with Behçet's syndrome. This investigation considered HLA associations with BS and HLA with certain clinical characteristics, age and sex in the (Tabriz) Iran which has an ethnically homogeneous population. HLA-A and HLA-B typing was performed in 290 BS patients, conforming to International Study Group criteria and in 300 blood donors, as controls. Patient records were retrospectively reviewed and patients reassessed clinically. HLA-B5, HLA-B35, HLA-51, HLA-B52 and HLA-CW4 presented significantly high frequencies in all patients. No other HLA type was associated. There was a significant HLA link with male sex in BS patients and Mean age (34 +/- 1.1) was determined. We present the frequency and correlation between Iranian Azari patients with Behçet's syndrome and particular HLA antigens. Ninety nine percent had mouth ulceration, 64% genital ulceration, 72% skin lesions and 52% ocular involvement. This study supports HLA-B5, HLA-B35, HLA-51, HLA-B52 and HLA-CW4 immunogenetic predisposition in an ethnically homogeneous (Iranian Azari) population.
ERIC Educational Resources Information Center
Friar, John T.
Two factors of predicted learning disorders were investigated: (1) inability to maintain appropriate classroom behavior (BEH), (2) perceptual discrimination deficit (PERC). Three groups of first-graders (BEH, PERC, normal control) were administered measures of impulse control, distractability, auditory discrimination, and visual discrimination.…
Willemse, Chandré M; Stander, Maria A; Vestner, Jochen; Tredoux, Andreas G J; de Villiers, André
2015-12-15
Changes in anthocyanin chemistry represent some of the most important transformations involved in red wine aging. However, accurate analysis of the derived pigments, as required to study the evolution of anthocyanins and tannins during aging, is hampered by their extreme structural diversity, low levels, and the fact that many of these compounds have identical mass spectral characteristics. In this context, chromatographic separation is critical. In this contribution, the application of online hydrophilic interaction chromatography (HILIC) × reversed-phase liquid chromatography (RP-LC) separation coupled to high-resolution mass spectrometry (MS) is described for the detailed characterization of anthocyanins and their derived pigments in aged red wine. A systematic approach was followed for the optimization of HILIC × RP-LC separation parameters using a capillary liquid chromatography (LC) system in the first dimension and an ultrahigh-pressure LC system in the second dimension to ensure maximum sensitivity and performance. Ninety four (94) anthocyanin-derived pigments were tentatively identified in one- and six-year-old Pinotage wines using accurate mass and fragmentation information obtained using quadrupole-time-of-flight mass spectrometry (Q-TOF-MS). Online HILIC × RP-LC-MS was found to offer high-resolution separation, because of the combination of two different separation modes, while the structured elution order observed improved the certainty in compound identification. Therefore, this approach shows promise for the detailed elucidation of the chemical alteration of anthocyanins during wine aging.
Thachil, Jecko V; Salim, Rahuman; Field, Anne; Moots, Robert; Bolton-Maggs, Paula
2008-03-01
Myelodysplastic syndrome (MDS) in children is often associated with chromosomal anomalies and trisomy 8 is a characteristic karyotypic feature in up to 20% of the cases. Behçet disease is a rare multisystem inflammatory disorder characterized by recurrent mouth and genital ulcers. MDS with trisomy 8 has been observed in adult patients with Behçet syndrome with some cases developing prior to the clinical manifestations of the latter. We present a female with a similar association and explain the importance of identifying the coexisting conditions. The immunological abnormalities, which may be observed in MDS and their possible mechanisms, are also discussed. (c) 2007 Wiley-Liss, Inc.
Ortiz-Villanueva, Elena; Tauler, Romà
2017-01-01
Metabolomics is a powerful and widely used approach that aims to screen endogenous small molecules (metabolites) of different families present in biological samples. The large variety of compounds to be determined and their wide diversity of physical and chemical properties have promoted the development of different types of hydrophilic interaction liquid chromatography (HILIC) stationary phases. However, the selection of the most suitable HILIC stationary phase is not straightforward. In this work, four different HILIC stationary phases have been compared to evaluate their potential application for the analysis of a complex mixture of metabolites, a situation similar to that found in non-targeted metabolomics studies. The obtained chromatographic data were analyzed by different chemometric methods to explore the behavior of the considered stationary phases. ANOVA-simultaneous component analysis (ASCA), principal component analysis (PCA) and partial least squares regression (PLS) were used to explore the experimental factors affecting the stationary phase performance, the main similarities and differences among chromatographic conditions used (stationary phase and pH) and the molecular descriptors most useful to understand the behavior of each stationary phase. PMID:29064436
Qiao, Lizhen; Shi, Xianzhe; Lu, Xin; Xu, Guowang
2015-05-29
Two tricationic ionic liquids were prepared and then bonded onto the surface of supporting silica materials through "thiol-ene" click chemistry as new stationary phases for high-performance liquid chromatography. The obtained columns of tricationic ionic liquids were evaluated respectively in the reversed-phase liquid chromatography (RPLC) mode and hydrophilic interaction liquid chromatography (HILIC) mode, and possess ideal column efficiency of 80,000 plates/m in the RPLC mode with naphthalene as the test solute. The tricationic ionic liquid stationary phases exhibit good hydrophobic and shape selectivity to hydrophobic compounds, and RPLC retention behavior with multiple interactions. In the HILIC mode, the retention and selectivity were evaluated through the efficient separation of nucleosides and bases as well as flavonoids, and the typical HILIC retention behavior was demonstrated by investigating retention changes of hydrophilic solutes with water volume fraction in mobile phase. The results show that the tricationic ionic liquid columns possess great prospect for applications in analysis of hydrophobic and hydrophilic samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Kallio, Heikki; Yang, Wei; Liu, Pengzhan; Yang, Baoru
2014-08-06
A rapid and sensitive method for profiling of proanthocyanidins (PAs) of sea buckthorn (Hippophaë rhamnoides) berries was established based on aqueous, acidified acetone extraction. The extract was purified by Sephadex column chromatography and analyzed using reversed-phase, normal-phase, and hydrophilic interaction liquid chromatography (HILIC). Negative ion electrospray ionization mass spectrometry (ESI-MS) in single ion recording (SIR) and full scan modes combined with UV detection were used to define the combinations and ratios of PA oligomer classes. PAs with degree of polymerization from 2 to 11 were detected by HILIC-ESI-MS. Quantification of dimeric, trimeric, and tetrameric PAs was carried out with ESI-MS-SIR, and their molar proportions were 40, 40, and 20%, respectively. Only B-type PAs were found, and (epi)gallocatechins were the main monomeric units. More than 60 combinations of (epi)catechins and (epi)gallocatechins of proanthocyanidin dimers and trimers were found. A majority of the PAs were shown to be higher polymers based on the HILIC-UV analysis.
Inoue, Koichi; Tanada, Chihiro; Sakamoto, Tasuku; Tsutsui, Haruhito; Akiba, Takashi; Min, Jun Zhe; Todoroki, Kenichiro; Yamano, Yutaka; Toyo'oka, Toshimasa
2015-08-15
In this study including the field of metabolomics approach for food, the evaluation of untargeted compounds using HILIC-ESI/TOF/MS and multivariate statistical analysis method is proposed for the assessment of classification, contamination and degradation of infant formula. HILIC mode is used to monitor more detected numbers in infant formulas in the ESI-positive scan mode than the reversed phase. The repeatability of the non-targeted contents from 4 kinds of infant formulas based on PCA was less than the relative standard deviation of 15% in all groups. The PCA pattern showed that significant differences in the classification of types and origins, the contamination of melamine and the degradations for one week were evaluated using HILIC-ESI/TOF/MS. In the S-plot from the degradation test, we could identify two markers by comparison to standards as nicotinic acid and nicotinamide. With this strategy, the differences from the untargeted compounds could be utilized for quality and safety assessment of infant formula. Copyright © 2015 Elsevier Ltd. All rights reserved.
Sommella, Eduardo; Pepe, Giacomo; Pagano, Francesco; Ostacolo, Carmine; Tenore, Gian Carlo; Russo, Maria Teresa; Novellino, Ettore; Manfra, Michele; Campiglia, Pietro
2015-10-01
Annurca apple, a Southern Italian cultivar, possesses not only a particular taste and flavor, different from other types of apple, but also several healthy properties. With the aim to thoroughly elucidate the polyphenolic profile of this variety, listed as Protected Geographical Indication product, an extensive qualitative profiling of Annurca apple polyphenolic peel extract was carried out, by employing a combination of ultra high performance reversed phase (RP-UHPLC) and hydrophilic liquid chromatography (HILIC) coupled to ion trap-time of flight (IT-TOF) mass spectrometry. A total of 63 compounds were tentatively identified, 25 of which not reported in Annurca apple extract so far. Furthermore, thanks to the different selectivity obtained with the HILIC, in combination with accurate mass measurements, an improved separation and detection of procyanidins, was obtained. Moreover, the obtained profiles were compared with those of a conventional variety, such as Red Delicious (RD), highlighting their differences. This work contributes to increase the knowledge about the polyphenolic fingerprint of this typical apple variety. Copyright © 2015 Elsevier Ltd. All rights reserved.
Belguendouz, H; Messaoudene, D; Lahmar-Belguendouz, K; Djeraba, Z; Otmani, F; Terahi, M; Tiar, M; Hartani, D; Lahlou-Boukoffa, O S; Touil-Boukoffa, C
2015-03-01
Uveitis represents one of the major diagnostic criteria in Behçet's disease. It is most prevalent in the countries of the Mediterranean area, including Algeria, and along the Silk Road. Clinical features include oral and genital ulcers, ocular and skin lesions, as well as central nervous system, joint, vascular, gastrointestinal, or pulmonary manifestations. Many studies have reported that Th1 immune responses are involved in the physiopathology. We have previously studied the production of IL-12 and IFN-γ, cytokine markers in the Th1 pathway involved in Behçet's disease. In our study, we investigate in vivo and in vitro IL-18 production in Algerian patients with Behçet's disease with ocular manifestations in various stages of the disease. We examined the effect of glucocorticoids on IL-18 production during the active stage of the disease. Our results suggest that IL-18 could be a good biomarker for monitoring disease activity and its regression, demonstrating the effectiveness of treatment on the underlying immunopathologic process. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Sazzini, Marco; Garagnani, Paolo; Sarno, Stefania; De Fanti, Sara; Lazzano, Teresa; Yang Yao, Daniele; Boattini, Alessio; Pazzola, Giulia; Maramotti, Sally; Boiardi, Luigi; Franceschi, Claudio; Salvarani, Carlo; Luiselli, Donata
2015-01-01
Behçet's disease is a multifactorial vasculitis that shows its highest prevalence in geographical areas historically involved in the Silk Road, suggesting that it might have originated somewhere along these ancient trade routes. This study aims to provide a first clue towards genetic evidence for this hypothesis by testing it via an anthropological evolutionary genetics approach. Behçet's disease variation at ancestry informative mitochondrial DNA control region and haplogroup diagnostic sites was characterised in 185 disease subjects of Italian descent and set into the Eurasian mitochondrial landscape by comparison with nearly 9,000 sequences representative of diversity observable in Italy and along the main Silk Road routes. Dissection of the actual genetic ancestry of disease individuals by means of population structure, spatial autocorrelation and haplogroup analyses revealed their closer relationships with some Middle Eastern and Central Asian groups settled along the Silk Road than with healthy Italians. These findings support the hypothesis that the Behçet's disease genetic risk has migrated to western Eurasia in parallel with ancestry components typical of Silk Road-related groups. This provided new insights that are useful to improve the understanding of disease origins and diffusion, as well as to inform future association studies aimed at properly accounting for the actual genetic ancestry of the examined Behçet's disease samples in order to minimise the detection of spurious associations and to improve the identification of genetic variants with actual clinical relevance.
Şenel, E; Demir, E; Alkan, R M
2017-03-01
Behçet disease (BD) is a chronic and multisystemic vasculitis characterized with recurrent oral and genital ulcers, uveitis, arthritis and skin manifestations. The highest prevalence of the disease has been reported in regions historically involved in the Silk Road routes. We aimed to analyse Behçet literature and evaluate whether there is a concordance between ancient Silk Road regions and the distribution of publication productivity. The bibliometric analysis of the publications published during 1980-2014 using Thomson Reuters Web of Science database was performed. We generated infographics of productivity and also analysed the correlations among economical productivities, technological advancement levels and humanity index and productivity performances of 78 countries in Behçet literature. Turkey ranked first in Behçet literature with 1837 articles followed by Japan and the USA. Turkey, Tunisia and Israel occupied the first three places in productivity. Significant correlations were noted between 2014 gross economic and technological indices and publication numbers of the countries. We found that European countries had high productivity, although they had low prevalence of BD. We detected no concordance between the productivity density of the countries and the ancient Silk Road routes. Most publications were reported from developed countries although undeveloped or developing countries had higher prevalence of BD. Physicians in undeveloped and developing countries should be supported and encouraged to perform novel studies on BD. © 2016 European Academy of Dermatology and Venereology.
Surgical treatment of Behçet's disease involving aortic regurgitation.
Ando, M; Kosakai, Y; Okita, Y; Nakano, K; Kitamura, S
1999-12-01
Behçet's disease involving aortic regurgitation is rare, and prosthetic valve detachment after aortic valve replacement is one of the most serious complications reported. We investigated the surgical results in 10 patients with aortic regurgitation caused by Behçet's disease. Between 1981 and 1997, 10 patients with aortic regurgitation secondary to Behçet's disease had surgery. There were 8 men and 2 women, and their ages ranged from 33 to 60 years (mean, 46+/-8 years). The surgical procedures for aortic regurgitation were aortic valve replacement in 6 patients and Bentall type operation in 4. No patient died during the hospital stay. The follow-up periods ranged from 11 to 185 months (mean, 87 months). Two patients died during the follow-up period. The acturial survival rate was 89% at 5 years and 67% at 10 years. Prosthetic valve detachment or suture detachment requiring redo operation occurred in 4 patients, 3 of whom had redo operations twice. Four patients had a composite graft replacement, and 1 patient died after the operation. No prosthetic valve detachment was noted in 64% of the patients at 5 years and in 43% at 10 years. The rate of prosthetic valve detachment was 40% (4 of 10 patients), with a higher incidence in patients with Behçet's disease than in those treated during the same period at the same hospital for aortitis caused by other diseases. Surgical techniques for treatment of this condition should be modified to improve the surgical outcome in these patients.
The immunogenetics of Behçet’s disease: A comprehensive review
Takeuchi, Masaki; Kastner, Daniel L; Remmers, Elaine F
2015-01-01
Behçet’s disease is a chronic multisystem inflammatory disorder characterized mainly by recurrent oral ulcers, ocular involvement, genital ulcers, and skin lesions, presenting with remissions and exacerbations. It is thought that both environmental and genetic factors contribute to its onset and development. Although the etiology of Behçet’s disease remains unclear, recent immunogenetic findings are providing clues to its pathogenesis. In addition to the positive association of HLA-B*51, which was identified more than four decades ago, and which has since been confirmed in multiple populations, recent studies report additional independent associations in the major histocompatibility complex class I region. HLA-B*15, -B*27, -B*57, and -A*26 are independent risk factors for Behçet’s disease, while HLA-B*49 and – A*03 are independent class I alleles that are protective for Behçet’s disease. Genome-wide association studies have identified associations with genome-wide significance (P < 5 × 10−8) in the IL23R–IL12RB2, IL10, STAT4, CCR1-CCR3, KLRC4, ERAP1, TNFAIP3, and FUT2 loci. In addition, targeted next-generation sequencing has revealed the involvement of rare nonsynonymous variants of IL23R, TLR4, NOD2, and MEFV in Behçet’s disease pathogenesis. Significant differences in gene function or mRNA expression associated with the risk alleles of the disease susceptibility loci suggest which genes in a disease-associated locus influence disease pathogenesis. These genes encompass both innate and adaptive immunity and confirm the importance of the predominant polarization towards helper T cell (Th) 1 versus Th2 cells, and the involvement of Th17 cells. In addition, epistasis observed between HLA-B*51 and the risk coding haplotype of the endoplasmic reticulum-associated protease, ERAP1, provides a clue that an HLA class I-peptide presentation-based mechanism contributes to this complex disease. PMID:26347074
Revisiting an old disease? Risk factors for bovine enzootic haematuria in the Kingdom of Bhutan.
Hidano, Arata; Sharma, Basant; Rinzin, Karma; Dahal, Narapati; Dukpa, Kinzang; Stevenson, Mark A
2017-05-01
Bovine enzootic haematuria (BEH) is a debilitating disease of cattle caused by chronic ingestion of bracken fern. Control of BEH is difficult when bracken fern is abundant and fodder resources are limited. To fill a significant knowledge gap on modifiable risk factors for BEH, we conducted a case-control study to identify cattle management practices associated with BEH in the Bhutanese cattle population. A case-control study involving 16 of the 20 districts of Bhutan was carried out between March 2012 and June 2014. In Bhutan sodium acid phosphate and hexamine (SAP&H) is used to treat BEH-affected cattle. All cattle greater than three years of age and treated with SAP&H in 2011 were identified from treatment records held by animal health offices. Households with at least one SAP&H-treated cattle were defined as probable cases. Probable case households were visited and re-classified as confirmed case households if the BEH status of cattle was confirmed following clinical examination and urinalysis. Two control households were selected from the same village as the case household. Households were eligible to be controls if: (1) householders reported that none of their cattle had shown red urine during the previous five years, and (2) haematuria was absent in a randomly selected animal from the herd following clinical examination. Details of cattle management practices were elicited from case and control householders using a questionnaire. A conditional logistic regression model was used to quantify the association between exposures of interest and household BEH status. A total of 183 cases and 345 controls were eligible for analysis. After adjusting for known confounders, the odds of free-grazing for two and three months in the spring were 3.81 (95% CI 1.27-11.7) and 2.28 (95% CI 1.15-4.53) times greater, respectively, in case households compared to controls. The odds of using fresh fern and dry fern as bedding in the warmer months were 2.05 (95% CI 1.03-4.10) and 2.08 (95% CI 0.88-4.90) times greater, respectively, in cases compared to controls. This study identified two husbandry practices that could be modified to reduce the risk of BEH in Bhutanese cattle. Avoiding the use of bracken fern as bedding is desirable, however, if fern is the only available material, it should be harvested during the colder months of the year. Improving access to alternative fodder crops will reduce the need for householders to rely on free-grazing as the main source of metabolisable energy for cattle during the spring. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, Hanxue; Yang, Tao; Cheng, Xuemei; Kwong, Sukfan; Liu, Chenghai; An, Rui; Li, Guowen; Wang, Xinhong; Wang, Changhong
2018-03-01
Usnea longissima Ach. (Usnea) is used in pharmaceuticals, food and cosmetics. Evernic acid (EA), barbatic acid (BA), diffractaic acid (DA) and usnic acid (UA) are the most typical ingredients in U. longissima and exert a wide variety of biological functions. The study aimed to develop a sensitive method for simultaneous analysis of EA, BA, DA and UA in rat plasma and was applied to pharmacokinetic studies after consumption of UA and ethanol extract from U. longissima (UE). The samples were separated on a BEH C 18 column by gradient elution with 0.5% formic acid in water and in methanol. The relative molecular masses of analytes were obtained in full-scan range from 50.0 to 750.0 m/z under negative ionization mode by UPLC-Q-Exactive Orbitrap MS. All validation parameters, such as lower limit of quantitation, linearity, specificity, precision, accuracy, extraction recovery, matrix effect and stability, were within acceptable ranges and the method was appropriate for biological specimen analysis. The pharmacokinetic results indicated that the absolute bioavailabilities of UA after oral administration of UA and UE reached 69.2 and 146.9%, respectively. Compared with UA in UE, the relative bioavailability of DA, BA and EA reached 103.7, 10.4 and 0.7% after oral administration of UE. Copyright © 2017 John Wiley & Sons, Ltd.
Cheng, Jian; Di, Liu-Qing; Shan, Jin-Jun; Zhao, Xiao-Li; Kang, An; Bi, Xiao-Lin; Li, Jun-Song
2014-04-01
To study on the effects of Achyranthes bidentata on Tongsaimai pellets main active ingredients chlorogenic acid, isoliquiritin, harpagoside and glycyrrhizin in rats in vivo pharmacokinetic behaviors, a method for the simultaneous determination of chlorogenic acid, isoliquiritin, harpagoside and liquiritigenin in rat plasma was established by UPLC-MS/MS. The analysis was performed on a waters Acquity BEH C18 column (2.1 mm x 100 mm, 1.7 microm) with the mixture of acetonitrile and 0.1% formic acid/water as mobile phase, and the gradient elution at a flow rate of 0.3 mL x min(-1). The analytes were detected by tandem mass spectrometry with the electrospray ionization (ESI) source and in the multiple reaction monitoring (MRM) mode. It turned out that the analytes of Tongsaimai pellets groups C(max) and AUC(Q-infinity) values were higher than that with A. bidentata group, and the C(max) values of chlorogenic acid had significantly difference (P < 0.05), the AUC(0-infinity) values of chlorogenic acid and glycyrrhizin had significantly difference (P < 0.05); The T(max) and CL values of two groups had no significantly difference. Results showed that the established method was specific, rapid, accurate and sensitive for the studies of Tongsaimai pellets four main active ingredients in rat in vivo pharmacokinetic, and A. bidentata have varying degrees of effects on Tongsaimai pellets four main active ingredients in rat in vivo pharmacokinetic behaviors.
Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Pingili Sunil; Prakash, Lakkireddy
2012-01-01
A novel, sensitive and selective stability-indicating gradient reverse phase ultra performance liquid chromatographic method was developed and validated for the quantitative determination of desloratadine and sodium benzoate in pharmaceutical oral liquid formulation. The chromatographic separation was achieved on Acquity BEH C8 (100 mm × 2.1 mm) 1.7 μm column by using mobile phase containing a gradient mixture of solvent A (0.05 M KH(2)PO(4) and 0.07 M triethylamine, pH 3.0) and B (50:25:25 v/v/v mixture of acetonitrile, methanol and water) at flow rate of 0.4 mL/min. Column temperature was maintained at 40°C and detection was carried out at a wavelength of 272 nm. The described method shows excellent linearity over a range of 0.254 μg/mL to 76.194 μg/mL for desloratadine and 1.006 μg/mL to 301.67 μg/mL for sodium benzoate. The correlation coefficient for desloratadine and sodium benzoate was more than 0.999. To establish stability-indicating capability of the method, drug product was subjected to the stress conditions of acid, base, oxidative, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from desloratadine and sodium benzoate. The developed method was validated as per international ICH guidelines with respect to specificity, linearity, LOD, LOQ, accuracy, precision and robustness.
Han, Zheng; Zheng, Yunliang; Chen, Na; Luan, Lianjun; Zhou, Changxin; Gan, Lishe; Wu, Yongjiang
2008-11-28
A new separation and quantification method using liquid chromatography under ultra-high-pressure in combination with tandem mass spectrometry (MS/MS) was developed for simultaneous determination of four alkaloids in Lindera aggregata. The analysis was performed on an Acquity UPLC BEH C(18) column (50mmx2.1mm, 1.7microm particle size; Waters, Milford, MA, USA) utilizing a gradient elution profile and a mobile phase consisting of (A) water containing 10mM ammonium acetate adjusted to pH 3 with acetic acid and (B) acetonitrile. An electrospray ionization (ESI)-tandem interface in the positive mode was employed prior to mass spectrometric detection. The calibration curve was linear over the range of 17.1-856ng for boldine, 42.4-2652ng for norboldine, 6.1-304ng for reticuline and 0.5-50ng for linderegatine, respectively. The average recoveries ranged from 99.2 to 101.4% with RSDs< or =2.7%. Then, four L. aggregata samples from different batches were analyzed using the established method. The results indicated that ultra-high-pressure liquid chromatography-tandem mass spectrometry provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LOQs) for most of target analytes compared to previous method employing conventional high-performance liquid chromatography (HPLC) separation. So, the established method was validated, sensitive and reliable for the determination of four alkaloids in L. aggregata.
Han, Miaomiao; Tian, Ying; Li, Zhen; Chen, Yiqiang; Yang, Wenjun; Zhang, Liying
2017-12-01
Chromium picolinate is one of the important Cr 3+ resources and is widely used in animal production. A convenient, reliable and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative determination of chromium picolinate in animal feeds. Feed samples were extracted with acetonitrile and subsequently cleaned up by solid phase extraction cartridges Supelclean™ LC-18. Chromium picolinate was efficiently separated with a Waters ACQUITY UPLC ® BEH C18 column, ionized with electrospray ion source in positive mode (ESI + ), and quantitatively determined by tandem mass spectrometry in multiple reaction monitoring mode. Standard calibration curve of chromium picolinate in the concentration range from 0.5 to 1000ng/mL was obtained with good linearity correlation coefficient (R 2 =0.9982). Average recoveries ranged from 95.37%∼105.54%, as detected by spiking 0.02∼640mg/kg of chromium picolinate in complete feed, concentrated feed and premix. Intra-day and inter-day coefficient of variation were 0.59%∼6.67% and 2.36%∼6.97%, respectively. The limits of quantitation were 0.02mg/kg, 0.025mg/kg, and 2mg/kg for complete feed, concentrated feed, and premix, respectively. Actual sample analysis indicated that the developed method can be an effective tool to monitoring CrPic content in animal feed. Copyright © 2017. Published by Elsevier B.V.
Guo, Zhening; Chen, Yangsheng; Ding, Xiaoliang; Huang, Chenrong; Miao, Liyan
2016-11-01
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry assay method was developed for simultaneous determination of ambroxol and salbutamol in human plasma using citalopram hydrobromide as internal standard (IS). The sample was alkalinized with ammonia water (33:67, v/v) and extracted by single liquid-liquid extraction with ethyl acetate. Separation was achieved on Waters Acquity UPLC BEH C 18 column using a gradient program at a flow rate of 0.2 mL/min. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the ion transitions m/z 378.9 → 263.6 (ambroxol), m/z 240.2 → 147.7 (salbutamol) and m/z 325.0 → 261.7 (IS). The total analytical run time was relatively short (3 min). Calibration curves were linear in the concentration range of 0.5-100.0 ng/mL for ambroxol and 0.2-20.0 ng/mL for salbutamol, with intra- and inter-run precision (relative standard deviation) <15% and accuracy (relative error) ranging from 97.7 to 112.1% for ambroxol and from 94.5 to 104.1% for salbutamol. The method was successfully applied in a clinical pharmacokinetic study of the compound ambroxol and salbutamol tablets. Copyright © 2016 John Wiley & Sons, Ltd.
Development of Immunopathogenesis Strategies to Treat Behçet's Disease
Köse, Osman
2012-01-01
Behçet disease is a chronic relapsing vasculitis with unclear etiology and immunopathogenesis. Antigenic stimuli, antigen presenting cells, T cells, monocyte, and neutrophil and endothelial cells are major parts of the pathology of the disease. Understanding of the new pathogenic mechanisms based on molecular structure of the disease helps us in improving the novel therapeutic modalities. These drugs target specific and nonspecific inhibition of the immun system. These therapies include biologic agents, new topical and systemic immunosuppressants, tolerizing agents, and immunoablation. Novel treatment will be promising to treat the especially recalcitrant cases to conventional therapy. In this paper, new aspect of the immunopathogenesis of Behçet's diseases and novel treatment modalities will be discussed. PMID:22550612
Plasma-Mediated Release of Morphine from Synthesized Prodrugs
2013-01-01
UPLC )9 (Waters Inc.) was utilized for measurements of morphine, PDA and PDB. UPLC has the capability to perform rapid (< 10 min) and reproducible...for UPLC versus ~30-50 µL for HPLC. The term “morphine” refers to the free morphine alkaloid base (Malinkrodt, etc.) unless otherwise stated...Baseline UPLC profiles were obtained for phosphate buffered saline (PBS), morphine and PDA in esterase de-activated plasma. Plasma was precipitated by the
Maher, Hadir M; Alzoman, Nourah Z; Shehata, Shereen M; Abahussain, Ashwag O
2017-04-15
Neratinib (NER) and pelitinib (PEL) are irreversible tyrosine kinase inhibitors (TKIs) that have been recently employed in cancer treatment. Apigenin (API), among other flavonoids, is known to have antioxidant, anti-proliferative, and carcinogenic effect. API can potentiate the antitumor effect of chemotherapeutic agents and/or alleviate the side effects of many anticancer agents. Since TKIs are mostly metabolized by CYP3A4 enzymes and that API could alter the enzymatic activity, potential drug interactions could be expected following their co-aministration. In the present study, a bioanalytical UPLC-MS/MS method has been developed and validated for the quantification of NER and PEL in rat plasma, using domperidone (DOM) as an internal standard. Sample preparation was carried out using solid phase extraction (SPE) with C18 cartridges with good extraction recovery of not less than 92.42% (NER) and 89.73% (PEL). Chromatographic analysis was performed on a Waters BEH C18 column with a mobile phase composed of acetonitrile and water, (70:30, v/v), each with 0.1% formic acid. Quantitation was performed using multiple reaction monitoring (MRM) of the transitions from protonated precursor ions [M+H] + , at m/z 557.30 (NER), m/z 468.21 (PEL), and at m/z 426.27 (DOM), to selected product ions at m/z 112.05 (NER), m/z 395.22 (PEL), and at m/z 175.18 (DOM). The method was fully validated as per the FDA guidelines over the concentration range of 0.5-200ng/mL with very low lower limit of quantification (LLOQ) of 0.5ng/mL for both NER and PEL. The intra- and inter-day assay precision and accuracy were evaluated for both drugs and the calculated values of percentage relative standards deviations (%RSD) and relative errors (%E r ) were within the acceptable limits (<15%) for concentrations other than LLOQ and 20% for LLOQ. The applicability of the method was extended to study the possibility of drug interactions following the oral co-administration of NER/PEL with API. Thus, this study could be readily applied in therapeutic drug monitoring (TDM) of cancerous patients receiving such drug combinations. Copyright © 2017 Elsevier B.V. All rights reserved.
Binkhorst, Lisette; Mathijssen, Ron H J; Ghobadi Moghaddam-Helmantel, Inge M; de Bruijn, Peter; van Gelder, Teun; Wiemer, Erik A C; Loos, Walter J
2011-12-15
In view of future pharmacokinetic studies, a highly sensitive ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method has been developed for the simultaneous quantification of tamoxifen and three of its main phase I metabolites in human lithium heparinized plasma. The analytical method has been thoroughly validated in agreement with FDA recommendations. Plasma samples of 200 μl were purified by liquid-liquid extraction with 1 ml n-hexane/isopropanol, after deproteination through addition of 50 μl acetone and 50 μl deuterated internal standards in acetonitrile. Tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and endoxifen were chromatographically separated on an Acquity UPLC(®) BEH C18 1.7 μm 2.1 mm×100 mm column eluted at a flow-rate of 0.300 ml/min on a gradient of 0.2mM ammonium formate and acetonitrile, both acidified with 0.1% formic acid. The overall run time of the method was 10 min, with elution times of 2.9, 3.0, 4.1 and 4.2 min for endoxifen, 4-hydroxy-tamoxifen, N-desmethyl-tamoxifen and tamoxifen, respectively. Tamoxifen and its metabolites were quantified by triple-quadrupole mass spectrometry in the positive ion electrospray ionization mode. The multiple reaction monitoring transitions were set at 372>72 (m/z) for tamoxifen, 358>58 (m/z) for N-desmethyl-tamoxifen, 388>72 (m/z) for 4-hydroxy-tamoxifen and 374>58 (m/z) for endoxifen. The analytical method was highly sensitive with the lower limit of quantification validated at 5.00 nM for tamoxifen and N-desmethyl-tamoxifen and 0.500 nM for 4-hydroxy-tamoxifen and endoxifen, which is equivalent to 1.86, 1.78, 0.194 and 0.187 ng/ml for tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and endoxifen, respectively. The method was also precise and accurate, with within-run and between-run precisions within 12.0% and accuracy ranging from 89.5 to 105.3%. The method has been applied to samples from a clinical study and cross-validated with a validated LC-MS/MS method in serum. Copyright © 2011 Elsevier B.V. All rights reserved.
Quantification of 21 antihypertensive drugs in serum using UHPLC-MS/MS.
Gundersen, Per Ole M; Helland, Arne; Spigset, Olav; Hegstad, Solfrid
2018-04-28
Poor drug adherence in hypertensive patients can lead to treatment failure and increased cardiovascular morbidity, as well as increased costs to society. An analytical method based on ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MSMS) was developed and validated for use in routine therapeutic drug monitoring (TDM). The method includes 21 antihypertensive drugs or active metabolites from the groups beta blockers (n=5), calcium antagonists (n=5), angiotensin II receptor antagonists (n=4), angiotensin converting enzyme (ACE) inhibitors (n=3) and diuretics (n = 3), in addition to one α1-selective alpha blocker. A 200 µL serum sample was handled automatically using a pipetting robot. Protein precipitation was performed with 600 µL of 1% formic acid in acetonitrile (v:v) and phospholipid removal was carried out using a Waters OSTRO™ 96-well plate. After evaporation and reconstitution the eluent was injected thrice with different inlet and mass spectrometric methods to cover the different physico-chemical properties of the drugs and the variations in therapeutic concentration ranges between drugs. Acquity UPLC BEH C18 (2.1x50mm, 1.7 µm) column equipped with a corresponding pre-column was used for chromatographic separation. For every analyte an isotopically labelled analogue served as internal standard, except for lisinopril where enalaprilat-d5 was used. Accuracies were in the range of -13.7 to 13.2% and intra-day and inter-day precisions in the range of 1.1 to 10.5%. The linearity within the calibration ranges expressed as coefficient of determination was higher than 0.995 for all compounds. Matrix effects and recovery efficiencies were within acceptable limits. The limits of quantitation varied from 0.02 to 10.7 µg/L. The stability of the drugs in serum at different conditions was tested. Diltiazem was not stable at 4-8 °C with up to 23.5 % loss after six days. Degradation of atenolol, irbesartan, bendroflumethiazide, hydrochlorothiazide and diltiazem was observed when stored at 30 °C. The suitability of the method was demonstrated in a routine TDM setting, analysing samples from 127 patients undergoing antihypertensive drug treatment. Copyright © 2018 Elsevier B.V. All rights reserved.
Xu, Qun; Tan, Shane; Petrova, Katya
2016-01-25
The European Pharmacopeia (EP) metoprolol impurities M and N are polar, nonchromophoric α-hydroxyamines, which are poorly retained in a conventional reversed-phase chromatographic system and are invisible for UV detection. Impurities M and N are currently analyzed by TLC methods in the EP as specified impurities and in the United States Pharmacopeia-National Formulary (USP-NF) as unspecified impurities. In order to modernize the USP monographs of metoprolol drug substances and related drug products, a hydrophilic interaction chromatography (HILIC) method coupled with a charged aerosol detector (CAD) was explored for the analysis of the two impurities. A comprehensive column screening that covers a variety of HILIC stationary phases (underivatized silica, amide, diol, amino, zwitterionic, polysuccinimide, cyclodextrin, and mixed-mode) and optimization of HPLC conditions led to the identification of a Halo Penta HILIC column (4.6 × 150 mm, 5 μm) and a mobile phase comprising 85% acetonitrile and 15% ammonium formate buffer (100 mM, pH 3.2). Efficient separations of metoprolol, succinic acid, and EP metoprolol impurities M and N were achieved within a short time frame (<8 min). The HILIC-CAD method was subsequently validated per USP validation guidelines with respect to specificity, robustness, linearity, accuracy, and precision, and could be incorporated into the current USP-NF monographs to replace the outdated TLC methods. Furthermore, the developed method was successfully applied to determine organic impurities in metoprolol drug substance (metoprolol succinate) and drug products (metoprolol tartrate injection and metoprolol succinate extended release tablets). Copyright © 2015 Elsevier B.V. All rights reserved.
West, Caroline; Auroux, Emeline
2016-08-26
Quantitative structure-retention relationships (QSRRs) furnish a detailed and reliable description of the role and extent of different molecular interactions that can be established between the analytes and the chromatographic system. Among QSRRs, the solvation parameter model using Abraham descriptors has gained acceptance as a general tool to explore the factors affecting retention in chromatographic systems. We have previously shown how a modified version of the solvation parameter model, with two extra terms to take account of interactions occurring with ionic and ionizable species (with positive and/or negative charges), could be applied to the characterization of hydrophilic interaction chromatographic (HILIC) systems. In the present study, we will show how this methodology can be used to evaluate the effects of increasing buffer salt concentration on retention and separation in a HILIC system. A commercial stationary phase possessing a sulfobetaine zwitterionic bonded ligand (Nucleodur HILIC) was used with a mobile phase composed of 80% acetonitrile and 20% pwwH4 ammonium acetate buffer, with aqueous buffer concentrations varying from 10 to 100mM, resulting in overall concentrations ranging from 2 to 20mM in the mobile phase. Retention factors were measured for a selection of 76 probe analytes. The chosen compounds are small molecules presenting a wide diversity of molecular structures and are relevant to biomedical and pharmaceutical applications. The QSRR models obtained allow for a rationalization of the interactions contributing to retention and separation in the HILIC system considered and shed some light on the effect of varying buffer salt concentration, namely the progressive transition from ion-exchange and electrostatic-repulsion mechanisms to hydrophilic partitioning. Copyright © 2016 Elsevier B.V. All rights reserved.
Balkatzopoulou, P; Fasoula, S; Gika, H; Nikitas, P; Pappa-Louisi, A
2015-05-29
In the present work the retention of three highly polar and ionizable solutes - uric acid, nicotinic acid and ascorbic acid - was investigated on a mixed-mode reversed-phase and weak anion-exchange (RP/WAX) stationary phase in buffered aqueous acetonitrile (ACN) mobile phases. A U-shaped retention behavior was observed for all solutes with respect to the eluent organic modifier content studied in a range of 5-95% (v/v). This retention behavior clearly demonstrates the presence of a HILIC-type retention mechanism at ACN-rich hydro-organic eluents and an RP-like retention at aqueous-rich hydro-organic eluents. Hence, this column should be promising for application under both RP and HILIC gradient elution modes. For this reason, a series of programmed elution runs were carried out with increasing (RP) and decreasing (HILIC) organic solvent concentration in the mobile phase. This dual gradient process was successfully modeled by two retention models exhibiting a quadratic or a cubic dependence of the logarithm of the solute retention factor (lnk) upon the organic modifier volume fraction (φ). It was found that both models produced by gradient retention data allow the prediction of solute retention times for both types of programmed elution on the mixed-mode column. Four, in the case of the quadratic model, or five, in the case of the cubic model, initial HILIC- and RP-type gradient runs gave satisfactory retention predictions of any similar kind elution program, even with different flow rate, with an overall error of only 2.5 or 1.7%, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.
Comparison of UPLC and HPLC methods for determination of vitamin C.
Klimczak, Inga; Gliszczyńska-Świgło, Anna
2015-05-15
Ultra performance liquid chromatography (UPLC) and high-performance liquid chromatography (HPLC) methods for determination of ascorbic acid (AA) and total AA (TAA) contents (as the sum of AA and dehydroascorbic acid (DHAA) after its reduction to AA) in fruit beverages and in pharmaceutical preparations were compared. Both methods are rapid: total time of analysis was 15 and 6 min for HPLC and UPLC methods, respectively. The methods were validated in terms of linearity, instrument precision, limits of detection (LOD) and quantification (LOQ), accuracy and recovery. Intra- and inter-day instrument precisions for fruit juices, expressed as RSD, were 2.2% and 2.4% for HPLC, respectively, and 1.7% and 1.9% for UPLC, respectively. For vitamin C tablets, inter- and intra-day precisions were 0.4% and 0.5%, respectively (HPLC), and 0.5% and 0.3%, respectively (UPLC). Both methods were sensitive: LOD was 0.049 μg/mL for HPLC and 0.024 μg/mL for UPLC while LOQs were 0.149 and 0.073 μg/mL for HPLC and UPLC, respectively. These methods could be useful in the routine qualitative and quantitative analysis of AA or TAA in pharmaceutical preparations or fruit beverages. However, UPLC method is more sensitive, faster and consumes less eluent. Copyright © 2014 Elsevier Ltd. All rights reserved.
Adherence to guidelines for the treatment of Behçet's syndrome in New York and Amsterdam.
Kerstens, Floor G; Turkstra, Franktien; Atalay, Selma; van Vugt, Richard M; Swearingen, Christopher J; Yazici, Yusuf
2017-01-01
To assess adherence to published guidelines for the treatment of Behçet's syndrome (BS) in two geographic areas. We extracted guideline statements from the 2008 EULAR recommendations. Adherence to these statements was evaluated retrospectively in both New York (USA) and Amsterdam (The Netherlands), by reviewing records from patients fulfilling the ISG criteria. We analysed data per statement and event, and divided data according to the year in which an event occurred. We compared events prior to 2009 to those after publication of the EULAR recommendations (2009 and later). 474 patients were evaluated, 24 of whom were from Amsterdam. Treatment adherence varied substantially across various Behçet's manifestations, ranging from 21% vs. 31% in posterior uveitis, 50% vs. 25% in arterial disease, 29% vs. 29% in arthritis and 38% vs. 55% in erythema nodosum to 65% vs. 67% in deep venous thrombosis (DVT), before and after publication of the guidelines respectively. Topical treatment of mucocutaneous disease was only 2% vs. 8%, whereas adherence in neuro-Behçet was ≥ 94% and 100% in gastrointestinal disease. Adherence to treatment guidelines varies substantially by Behçet's manifestation. Lack of adherence in manifestations such as eye disease and arthritis suggests that current recommendations are not sufficient or other concurrent manifestations require more aggressive treatment. The extensive use of anti-TNF agents might indicate a shift towards more aggressive treatment. Thus, our results suggest the 2008 guidelines were not in line with treatment in clinical practice over the past years and the recent revision of the recommendations was indeed needed.
Hydrogen mobility in the lightest reversible metal hydride, LiBeH 3
Mamontov, Eugene; Kolesnikov, Alexander I.; Sampath, Sujatha; ...
2017-11-24
Lithium-beryllium metal hydrides, which are structurally related to their parent compound, BeH 2, offer the highest hydrogen storage capacity by weight among the metal hydrides (15.93 wt. % of hydrogen for LiBeH 3). Challenging synthesis protocols have precluded conclusive determination of their crystallographic structure to date, but here we analyze directly the hydrogen hopping mechanisms in BeH 2 and LiBeH 3 using quasielastic neutron scattering, which is especially sensitive to single-particle dynamics of hydrogen. We find that, unlike its parent compound BeH 2, lithium-beryllium hydride LiBeH 3 exhibits a sharp increase in hydrogen mobility above 265 K, so dramatic thatmore » it can be viewed as melting of hydrogen sublattice. We perform comparative analysis of hydrogen jump mechanisms observed in BeH 2 and LiBeH 3 over a broad temperature range. As microscopic diffusivity of hydrogen is directly related to its macroscopic kinetics, a transition in LiBeH 3 so close to ambient temperature may offer a straightforward and effective mechanism to influence hydrogen uptake and release in this very lightweight hydrogen storage compound.« less
Keogan, M T
2009-01-01
Patients presenting with recurrent orogenital ulcers may have complex aphthosis, Behçet's disease, secondary complex aphthosis (e.g. Reiter's syndrome, Crohn's disease, cyclical neutropenia) or non-aphthous disease (including bullous disorders, erythema multiforme, erosive lichen planus). Behçet's syndrome is a multi-system vasculitis of unknown aetiology for which there is no diagnostic test. Diagnosis is based on agreed clinical criteria that require recurrent oral ulcers and two of the following: recurrent genital ulcers, ocular inflammation, defined skin lesions and pathergy. The condition can present with a variety of symptoms, hence a high index of suspicion is necessary. The most common presentation is with recurrent mouth ulcers, often with genital ulcers; however, it may take some years before diagnostic criteria are met. All patients with idiopathic orogenital ulcers should be kept under review, with periodic focused assessment to detect evolution into Behçet's disease. There is often a delay of several years between patients fulfilling diagnostic criteria and a diagnosis being made, which may contribute to the morbidity of this condition. Despite considerable research effort, the aetiology and pathogenesis of this condition remains enigmatic. PMID:19210521
Uygunoğlu, Uğur; Benbir, Gulcin; Saip, Sabahattin; Kaynak, Hakan; Siva, Aksel
2014-01-01
Brainstem is the most common site of involvement in neuro-Behçet syndrome (NBS). On the other hand, the critical importance of this anatomical region in the regulation of sleep has been disregarded in the literature. We aimed to investigate the microstructure of sleep in patients with Behçet syndrome (BS) and NBS. Patients were allocated to 2 groups: (1) BS without any neurological involvement and (2) NBS with brainstem lesions only. A control group was also enrolled in this study. The comparison of polysomnographic parameters between all patients (BS and NBS) with the control group showed that sleep onset was longer (p = 0.006), the duration of superficial NREM sleep stage (N2) was significantly longer (p = 0.018), and the respiratory disturbance index was significantly higher (p = 0.034) in patients. Sleep apnea and restless legs syndrome are more commonly observed in BS and NBS. Our findings emphasize the importance of questioning the quality of sleep and its disorders in patients with BS in order to better handle the common somatic complaints in these patients, such as fatigue or daytime sleepiness . © 2014 S. Karger AG, Basel.
Intestinal Behçet and Crohn's disease: two sides of the same coin.
Valenti, Simona; Gallizzi, Romina; De Vivo, Dominique; Romano, Claudio
2017-04-20
Behçet's disease (BD) and Crohn's disease (CD) are chronic immune-mediated, inflammatory disorders affecting many different systems (joints, skin, eyes, gastrointestinal and biliary tracts). Both disorders have fluctuating courses and when gastrointestinal symptoms are prevalent, differential diagnosis can be difficult. BD involves the gastrointestinal tract in 10-15% of cases with localized lesions in the ileocecal region. The clinical picture is heterogeneous with various clusters of disease expression. CD is a chronic inflammatory disorder, which can affect any part of the intestinal tract, as well as extra-intestinal tissue. Factors that contribute towards the pathogenesis of both disease include the host's genetic profile, and immune system, and environmental factors such as the gut microbiota. The aim of this manuscript is to provide a narrative review of clinical features of BD and CD, highlighting the importance of differential diagnosis and therapeutic approach, especially in the presence of gastrointestinal involvement. A comprehensive search of published literature using the Pubmed ( http://www.ncbi.nlm.nih.gov/pubmed/ ) database was carried out to identify all articles published in English from 1999 to October 2016, using 4 key terms: "Behçet Disease", "Intestinal Behçet's Disease", "Crohn's Disease" and" Inflammatory Bowel Disease".
Bos, Sandra; Viranaicken, Wildriss; Turpin, Jonathan; El-Kalamouni, Chaker; Roche, Marjolaine; Krejbich-Trotot, Pascale; Desprès, Philippe; Gadea, Gilles
2018-03-01
Mosquito-borne Zika virus (ZIKV) recently emerged in South Pacific islands and Americas where large epidemics were documented. In the present study, we investigated the contribution of the structural proteins C, prM and E in the permissiveness of human host cells to epidemic strains of ZIKV. To this end, we evaluated the capacity of the epidemic strain BeH819015 to infect epithelial A549 and neuronal SH-SY5Y cells in comparison to the African historical MR766 strain. For that purpose, we generated a molecular clone of BeH819015 and a chimeric clone of MR766 which contains the BeH819015 structural protein region. We showed that ZIKV containing BeH819015 structural proteins was much less efficient in cell-attachment leading to a reduced susceptibility of A549 and SH-SY5Y cells to viral infection. Our data illustrate a previously underrated role for C, prM, and E in ZIKV epidemic strain ability to initiate viral infection in human host cells. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Hydrogen mobility in the lightest reversible metal hydride, LiBeH 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mamontov, Eugene; Kolesnikov, Alexander I.; Sampath, Sujatha
Lithium-beryllium metal hydrides, which are structurally related to their parent compound, BeH 2, offer the highest hydrogen storage capacity by weight among the metal hydrides (15.93 wt. % of hydrogen for LiBeH 3). Challenging synthesis protocols have precluded conclusive determination of their crystallographic structure to date, but here we analyze directly the hydrogen hopping mechanisms in BeH 2 and LiBeH 3 using quasielastic neutron scattering, which is especially sensitive to single-particle dynamics of hydrogen. We find that, unlike its parent compound BeH 2, lithium-beryllium hydride LiBeH 3 exhibits a sharp increase in hydrogen mobility above 265 K, so dramatic thatmore » it can be viewed as melting of hydrogen sublattice. We perform comparative analysis of hydrogen jump mechanisms observed in BeH 2 and LiBeH 3 over a broad temperature range. As microscopic diffusivity of hydrogen is directly related to its macroscopic kinetics, a transition in LiBeH 3 so close to ambient temperature may offer a straightforward and effective mechanism to influence hydrogen uptake and release in this very lightweight hydrogen storage compound.« less
[Neuro-neutrophilic Disease and Dementia].
Hisanaga, Kinya
2016-04-01
Neuro-neutrophilic diseases are multisystem inflammatory disorders that include neuro-Behçet and neuro-Sweet disease. These disorders ectopically damage the nervous system due to the abnormal chemotaxis of neutrophils. The neutrophils' chemotaxis is induced by oral muco-cutaneous bacterial infections and the dysregulation of cytokines, including interleukins. The frequencies of human leukocyte antigen (HLA)-B51 in neuro-Behçet disease and HLA-B54 as well as Cw1 in neuro-Sweet disease significantly higher than the levels present in Japanese normal controls. Notably, their frequencies are also higher in patients exhibiting neurological complications than in patients without neurological complications. These HLA types are considered risk factors that are directly related to the etiology of these diseases. Prednisolone and colchicine, which suppress neutrophil activation, are used to treat the acute phase of both diseases. Alternatively, dapsone is prescribed to prednisolone-dependent recurrent cases of neuro-Sweet disease. Dementia is a neurological symptom of these disorders, especially in the chronic progressive subtype of neuro-Behçet disease. Other immunosuppressant drugs, including methotrexate and infliximab, are administered to patients with the chronic progressive type of neuro-Behçet disease. Neuro-neutrophilic diseases are a form of dementia considered treatable.
A Clinical Picture of the Visual Outcome in Adamantiades-Behçet's Disease
Figus, Michele; Albert, Timothy G.; Talarico, Rosaria; Nardi, Marco
2015-01-01
Adamantiades-Behçet's disease is a multisystemic vasculitis with multiorgan involvement. Ocular disorders occur often in this syndrome typically in the form of a relapsing-remitting panuveitis and vasculitis and can lead to blindness as one of its most disabling complications if left untreated. There are known risk factors related with the worst visual prognosis, which require early and intensive treatment in order to obtain a rapid suppression of inflammation and to prevent future relapses. The management strategy to avoid vision loss and blindness currently involves the use of local and systemic drugs including steroids and immunosuppressive and biologic agents. This review aims to demonstrate how the introduction and the use of biologic agents improves the visual outcome of patients with Adamantiades-Behçet's disease. PMID:26558256
Cífková, Eva; Hájek, Roman; Lísa, Miroslav; HolĿapek, Michal
2016-03-25
The goal of this work is a systematic optimization of hydrophilic interaction liquid chromatography (HILIC) separation of acidic lipid classes (namely phosphatidic acids-PA, lysophosphatidic acids-LPA, phosphatidylserines-PS and lysophosphatidylserines-LPS) and other lipid classes under mass spectrometry (MS) compatible conditions. The main parameters included in this optimization are the type of stationary phases used in HILIC, pH of the mobile phase, the type and concentration of mobile phase additives. Nine HILIC columns with different chemistries (unmodified silica, modified silica using diol, 2-picolylamine, diethylamine and 1-aminoanthracene and hydride silica) are compared with the emphasis on peak shapes of acidic lipid classes. The optimization of pH is correlated with the theoretical calculation of acidobasic equilibria of studied lipid classes. The final method using the hydride column, pH 4 adjusted by formic acid and the gradient of acetonitrile and 40 mmol/L of aqueous ammonium formate provides good peak shapes for all analyzed lipid classes including acidic lipids. This method is applied for the identification of lipids in real samples of porcine brain and kidney extracts. Copyright © 2016 Elsevier B.V. All rights reserved.
Hetrick, Evan M; Kramer, Timothy T; Risley, Donald S
2017-03-17
Based on a column-screening exercise, a column ranking system was developed for sample mixtures containing any combination of 26 sugar and sugar alcohol analytes using 16 polar stationary phases in the HILIC mode with acetonitrile/water or acetone/water mobile phases. Each analyte was evaluated on the HILIC columns with gradient elution and the subsequent chromatography data was compiled into a statistical software package where any subset of the analytes can be selected and the columns are then ranked by the greatest separation. Since these analytes lack chromophores, aerosol-based detectors, including an evaporative light scattering detector (ELSD) and a charged aerosol detector (CAD) were employed for qualitative and quantitative detection. Example qualitative applications are provided to illustrate the practicality and efficiency of this HILIC column ranking. Furthermore, the design-space approach was used as a starting point for a quantitative method for the trace analysis of glucose in trehalose samples in a complex matrix. Knowledge gained from evaluating the design-space led to rapid development of a capable method as demonstrated through validation of the following parameters: specificity, accuracy, precision, linearity, limit of quantitation, limit of detection, and range. Copyright © 2017 Elsevier B.V. All rights reserved.
Inoue, Koichi; Miyazaki, Yasuto; Unno, Keiko; Min, Jun Zhe; Todoroki, Kenichiro; Toyo'oka, Toshimasa
2016-01-01
In this study, we developed the stable isotope dilution hydrophilic interaction liquid chromatography with tandem mass spectrometry (HILIC-MS/MS) technique for the accurate, reasonable and simultaneous quantification of glutamic acid (Glu), glutamine (Gln), pyroglutamic acid (pGlu), γ-aminobutyric acid (GABA) and theanine in mouse brain tissues. The quantification of these analytes was accomplished using stable isotope internal standards and the HILIC separating mode to fully correct the intramolecular cyclization during the electrospray ionization. It was shown that linear calibrations were available with high coefficients of correlation (r(2) > 0.999, range from 10 pmol/mL to 50 mol/mL). For application of the theanine intake, the determination of Glu, Gln, pGlu, GABA and theanine in the hippocampus and central cortex tissues was performed based on our developed method. In the region of the hippocampus, the concentration levels of Glu and pGlu were significantly reduced during reality-based theanine intake. Conversely, the concentration level of GABA increased. This result showed that transited theanine has an effect on the metabolic balance of Glu analogs in the hippocampus. Copyright © 2015 John Wiley & Sons, Ltd.
Leijdekkers, Antonius G M; Huang, Jie-Hong; Bakx, Edwin J; Gruppen, Harry; Schols, Henk A
2015-03-02
Separation and characterization of complex mixtures of pectic oligosaccharides still remains challenging and often requires the use of multiple analytical techniques, especially when isomeric structures are present. In this work, it is demonstrated that the coupling of hydrophilic interaction chromatography (HILIC) to traveling-wave ion mobility mass spectrometry (TWIMMS) enabled the simultaneous separation and characterization of complex mixtures of various isomeric pectic oligosaccharides. Labeling of oligosaccharides with 3-aminoquinoline (3-AQ) improved MS-ionization efficiency of the oligosaccharides and reduced the complexity of the product ion mass spectra, without losing resolution of the HILIC separation. In addition, labeling enabled quantification of oligosaccharides on molar basis using in-line fluorescence detection. Isomeric structures were distinguished using TWIMMS. The 3-AQ-HILIC-TWIMMS method was used to characterize a series of isomeric sugar beet rhamnogalacturonan I derived oligosaccharides carrying a glucuronic acid substituent. Thereby, some novel structural features were identified for the first time: glucuronic acid was attached to O-3 or to O-2 of galacturonic acid residues and a single galacturonic acid residue within an oligomer could contain both an acetyl group and a glucuronic acid substituent. Copyright © 2014 Elsevier Ltd. All rights reserved.
Li, Fangbing; Wang, Hui; Xin, Huaxia; Cai, Jianfeng; Fu, Qing; Jin, Yu
2016-12-01
Purified standards of xylooligosaccharides (XOSs) (DP2-6) were first prepared from a mixture of XOSs using solid phase extraction (SPE), followed by semi-preparative liquid chromatography both under hydrophilic interaction liquid chromatography (HILIC) modes. Then, an accurate quantitative analysis method based on hydrophilic interaction liquid chromatography-evaporative light scattering detection (HILIC-ELSD) was developed and validated for simultaneous determination of xylose (X1), xylobiose (X2), xylotriose (X3), xylotetraose (X4), xylopentaose (X5), and xylohexaose (X6). This developed HILIC-ELSD method was applied to the comparison of different hydrolysis methods for xylans and assessment of XOSs contents from different agricultural wastes. The result indicated that enzymatic hydrolysis was preferable with fewer by-products and high XOSs yield. The XOSs yield (48.40%) from sugarcane bagasse xylan was the highest, showing conversions of 11.21g X2, 12.75g X3, 4.54g X4, 13.31g X5, and 6.78g X6 from 100g xylan. Copyright © 2016 Elsevier Ltd. All rights reserved.
Aral, Tarık; Aral, Hayriye; Ziyadanoğulları, Berrin; Ziyadanoğulları, Recep
2015-01-01
A novel mixed-mode stationary phase was synthesised starting from N-Boc-glutamine, aniline and spherical silica gel (4 µm, 60 Å). The prepared stationary phase was characterized by IR and elemental analysis. The new stationary phase bears an embedded amide group into phenyl ring, highly polar a terminal amide group and non-polar groups (phenyl and alkyl groups). At first, this new mixed-mode stationary phase was used for HILIC separation of four nucleotides and five nucleosides. The effects of different separation conditions, such as pH value, mobile phase and temperature, on the separation process were investigated. The optimum separation for nucleotides was achieved using HILIC isocratic elution with aqueous mobile phase and acetonitrile with 20°C column temperature. Under these conditions, the four nucleotides could be separated and detected at 265 nm within 14 min. Five nucleosides were separated under HILIC isocratic elution with aqueous mobile phase containing pH=3.25 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 265 nm within 14 min. Chromatographic parameters as retention factor, selectivity, theoretical plate number and peak asymmetry factor were calculated for the effect of temperature and water content in mobile phase on the separation process. The new column was also tested for nucleotides and nucleosides mixture and six analytes were separated in 10min. The chromatographic behaviours of these polar analytes on the new mixed-model stationary phase were compared with those of HILIC columns under similar conditions. Further, phytohormones and phenolic compounds were separated in order to see influence of the new stationary phase in reverse phase conditions. Eleven plant phytohormones were separated within 13 min using RP-HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 230 or 278 nm. The best separation conditions for seven phenolic compounds was also achieved using reversed-phase HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and seven phenolic compounds could be separated and detected at 230 nm within 16 min. Copyright © 2014 Elsevier B.V. All rights reserved.
Gritti, Fabrice; Guiochon, Georges
2013-03-22
The adsorption behaviors of a neutral (caffeine) and a positively charged compound (nortriptylinium) are investigated on two RPLC/hybrid stationary phases, eluted with a low ionic strength buffer (phosphate buffer, W(S)pH 2.63, I=10mM). The first phase, bridge ethylene hybrid (BEH), is neutral at all pHs whereas the second, charged surface hybrid (CSH), contains a protonated ligand at W(W)pH <7. The band profiles of these two compounds eluted by mixture of acetonitrile and water were recorded under overloaded conditions. The adsorption isotherms of the neutral compound on both columns were well accounted for by a heterogeneous Linear-Langmuir (LL) model, which has an adsorption-desorption equilibrium constants about twice larger for caffeine on the CSH than on the BEH, due to charge-dipole interactions. In contrast, at low loadings (0.3 and 1.2μL, C=30g/L), the adsorption isotherm of the charged compound can be accounted for by a homogeneous electrostatically modified Langmuir (EML) or by a heterogeneous bi-EML implicit isotherms onto the CSH and BEH adsorbent, respectively. Electrostatic repulsions definitely account the lesser retention of the ionizable compound on CSH than on BEH. This is explained by the surface potential of CSH-C18 at 20mV and by the subsequent decrease of the equilibrium constant of weak adsorption sites (C18 environment) and removal of the strong adsorption sites (accessible silanols). At the highest sample loadings (5 and 20μL, C=30g/L), the EML and the bi-EML isotherms failed because some adsorbate-adsorbate interactions take place when bulk concentrations exceed 0.2g/L. The experimental data were then successively fitted to an empirical heterogeneous Langmuir-Moreau (LM) explicit isotherm. The best saturation capacities of the empirical heterogeneous LM isotherm is consistent with the manufacturer's estimate of the surface concentration of residual silanols onto the BEH- and CSH-C18 endcapped adsorbent (<0.1μmol/m(2)). Copyright © 2013 Elsevier B.V. All rights reserved.
[UPLC characteristic chromatographic profile of Poria].
Zhang, Qi; Wang, Zhenzhong; Xiao, Wei; Zhang, Liangqi; Bi, Kaishun; Jia, Ying
2012-04-01
To establish a UPLC characteristic chromatographic profile analysis method to quickly assess Poria quality and provide basis fro controlling Poria quality. The UPLC characteristic chromatographic profiles of fifteen batches of Poria were determined by ACQUITY UPLC, with HSS T3 Column (2.1 mm x 100 mm, 1.8 microm) eluted with the mobile phases of water containing 0.05% phosphoric acid and acetonitrile in gradient mode. The detection wavelength was set at 243 nm. The common mode of the UPLC characteristic chromatographic profile was set up. There were 20 common peaks, seven of which were identified, and the similar degrees of the fifteen samples to the common mode were between 0.787 and 0.974. The method was so time-saving that it can be used for the quality control of Poria.
Churchwell, Mona I; Twaddle, Nathan C; Meeker, Larry R; Doerge, Daniel R
2005-10-25
Recent technological advances have made available reverse phase chromatographic media with a 1.7 microm particle size along with a liquid handling system that can operate such columns at much higher pressures. This technology, termed ultra performance liquid chromatography (UPLC), offers significant theoretical advantages in resolution, speed, and sensitivity for analytical determinations, particularly when coupled with mass spectrometers capable of high-speed acquisitions. This paper explores the differences in LC-MS performance by conducting a side-by-side comparison of UPLC for several methods previously optimized for HPLC-based separation and quantification of multiple analytes with maximum throughput. In general, UPLC produced significant improvements in method sensitivity, speed, and resolution. Sensitivity increases with UPLC, which were found to be analyte-dependent, were as large as 10-fold and improvements in method speed were as large as 5-fold under conditions of comparable peak separations. Improvements in chromatographic resolution with UPLC were apparent from generally narrower peak widths and from a separation of diastereomers not possible using HPLC. Overall, the improvements in LC-MS method sensitivity, speed, and resolution provided by UPLC show that further advances can be made in analytical methodology to add significant value to hypothesis-driven research.
Sibley, Cailin; Yazici, Yusuf; Tascilar, Koray; Khan, Nafiz; Bata, Yasmin; Yazici, Hasan; Goldbach-Mansky, Raphaela; Hatemi, Gulen
2014-07-01
To compare clinical manifestations and activity of Behçet syndrome (BS) in the United States versus Turkey using validated outcome measures. Consecutive patients with BS from the US National Institutes of Health (NIH), New York University, and the University of Istanbul were evaluated. Disease activity was measured using the Behçet's Syndrome Activity Scale (BSAS) and the Behçet's Disease Current Activity Form (BDCAF) with quality of life measured by the Behçet Disease Quality of Life (BDQOL) form. One-way ANOVA, t-tests, and multivariate regression analyses were performed. Mean age did not differ between sites; however, more women were seen in the United States versus in Turkey (p < 0.001), and disease duration was longer in the United States (p = 0.02). Organ manifestations were similar for oral and genital ulcers, skin disease, arthralgia, eye disease, and thrombosis. However, more gastrointestinal (p < 0.001) and neurologic disease (p = 0.003) was seen in the United States. BSAS and BDCAF scores were worse in the United States compared to Turkey (p = 0.013 and < 0.001, respectively). Worse mean BDQOL scores were observed at the NIH compared to Istanbul (not significant). Multivariable regression models showed worse scores in ethnically atypical patients for BSAS and BDCAF (p = 0.04 and p = 0.001), American patients for BDCAF (p = 0.01), older age for BDCAF (p = 0.005), and women for BDQOL (p = 0.01). Demographic and clinical manifestations of BS differ between sites with higher disease activity in the United States compared to Turkey. Referral patterns, age, sex, ethnicity, and country of origin may be important in these differences. These observations raise the question of whether pathogenic mechanisms differ in Turkish and American patients.
Use of ultra-wide-field retinal imaging in the management of active Behçet retinal vasculitis.
Mesquida, Marina; Llorenç, Victor; Fontenla, José Ramón; Navarro, Manuel Javier; Adán, Alfredo
2014-10-01
Retinal vasculitis (RV) is an important component of Behçet disease. It may be difficult to detect either clinically or with conventional retinal imaging. The role of ultra-wide-field (UWF) retinal imaging was assessed in the diagnosis and management of RV associated with Behçet disease. A total of 38 eyes of 20 patients with active RV associated to Behçet disease underwent UWF imaging with the Optos scanning laser ophthalmoscope, fundus autofluorescence, and/or fluorescein angiography. This study determined the UWF findings and percentage of patients in whom this imaging modality assisted in diagnosing the extent of vasculitis, planning treatment, and monitoring disease activity. Optos UWF imaging assisted in diagnosing and quantifying the extent of RV in 16 patients (80%), planning medical treatment or laser photocoagulation in 13 of 20 patients (65%), and enhanced disease monitoring in 11 of 20 patients (55%). UWF fluorescein angiography revealed vasculitis not clinically evident in 28 of 33 eyes (84.8%). Predominant angiographic findings were diffuse vascular leakage (75.7%), peripheral retinal nonperfusion (66.7%), optic disk leakage (63.6%), macular leakage (30.3%), and macular edema (27.3%). Eighteen patients (34 eyes) underwent UWF fundus autofluorescence, showing multiple hyperfluorescent spots in retinal periphery in 28 eyes (82.3%). Ultra-wide-field imaging is a valuable tool in the management of patients with RV associated to Behçet disease and can be used for the diagnosis, treatment, and follow-up. Additional studies, including longitudinal evaluations, are needed to elucidate whether these findings or the subsequent management alterations may improve patients' outcomes.
NASA Astrophysics Data System (ADS)
Beach, Daniel G.
2017-08-01
Paralytic shellfish toxins (PSTs) are neurotoxins produced by dinoflagellates and cyanobacteria that cause paralytic shellfish poisoning in humans. PST quantitation by LC-MS is challenging because of their high polarity, lability as gas-phase ions, and large number of potentially interfering analogues. Differential mobility spectrometry (DMS) has the potential to improve the performance of LC-MS methods for PSTs in terms of selectivity and limits of detection. This work describes a comprehensive investigation of the separation of 16 regulated PSTs by DMS and the development of highly selective LC-DMS-MS methods for PST quantitation. The effects of all DMS parameters on the separation of PSTs from one another were first investigated in detail. The labile nature of 11α-gonyautoxin epimers gave unique insight into fragmentation of labile analytes before, during, and after the DMS analyzer. Two sets of DMS parameters were identified that either optimized the resolution of PSTs from one another or transmitted them at a limited number of compensation voltage (CV) values corresponding to structural subclasses. These were used to develop multidimensional LC-DMS-MS/MS methods using existing HILIC-MS/MS parameters. In both cases, improved selectivity was observed when using DMS, and the quantitative capabilities of a rapid UPLC-DMS-MS/MS method were evaluated. Limits of detection of the developed method were similar to those without DMS, and differences were highly analyte-dependant. Analysis of shellfish matrix reference materials showed good agreement with established methods. The developed methods will be useful in cases where specific matrix interferences are encountered in the LC-MS/MS analysis of PSTs in complex biological samples.
Evidence for an imidazoline by-product from glycans using tandem mass spectrometry.
Duff, Robert J; Smith, Elaine; Li, Wenzhou; Fodor, Szilan
2017-06-09
Herein is reported the separation and identification of a previously unknown imidazoline by-product originating from the fluorescent labeling procedure when applied to enzymatically released N-linked glycans of a human IgG1. The imidazoline by-product was generated via the reductive amination procedure with either sodium cyanoborohydride or 2-picoline borane. Using ultra performance liquid chromatography (UPLC) in conjunction with hydrophilic interaction-based chromatography (HILIC), the 2-aminobenzoic acid (2-AA)-labeled glycans were well-resolved from imidazoline by-products to facilitate direct identification utilizing electrospray ionization mass spectrometry (ESI-MS) with fragmentation. It was found that this minor species (∼2%) was 18.0105u less than the neighboring peak GlcNAc 2 Man 3 GlcNAc 2 Fuc peak, abbreviated as A2G0F at 1582.5899u. While this mass loss corresponds to the mass of a water molecule, the molecular location of loss of water was not straightforward in consideration of the biantennary A2G0F structure. Model studies were carried out using A2G0F standard and N-acetyllactosamine to identify the impurity as an imidazoline ring structure located at the reducing end of the glycan as confirmed by high resolution mass fragment ions. Imidazoline content decreased when the reductant concentration was increased. To conclude, evidence for the imidazoline structure was accomplished through high resolution, high accuracy mass spectrometry (HRAM), and experiments showing chemical susceptibility and isotopically labeled tracers. This study is the first to identify these minor species which likely impact all N-acetylglucosamine-type N-linked glycans from biologics. Copyright © 2017 Elsevier B.V. All rights reserved.
Behçet syndrome: from pathogenesis to novel therapies.
Mazzoccoli, Gianluigi; Matarangolo, Angela; Rubino, Rosa; Inglese, Michele; De Cata, Angelo
2016-02-01
Behçet syndrome is a chronic disease hallmarked by inflammation of the blood vessels that is related to an autoimmune reaction caused by inherited susceptibility due to specific genes and environmental factors, probably components of infectious microorganisms, which turn on or get going the disease in genetically susceptible subjects. The more common clinical expression of the disease is represented by a triple-symptom complex of recurrent oral aphthous ulcers, genital ulcers, and uveitis, sometimes associated with inflammatory arthritis, phlebitis, iritis, as well as inflammation of the digestive tract, brain, and spinal cord. The treatment strategies used to manage the manifestations of Behçet syndrome have gradually progressed, and a number of new therapeutic resources have been implemented in recent years, allowing better control of pathogenic mechanisms, reducing symptoms and suffering, and ameliorating patient's outcome.
Ludwig, Katelyn R.; Sun, Liangliang; Zhu, Guijie; Dovichi, Norman J.; Hummon, Amanda B.
2015-01-01
Ultra-performance liquid chromatography (UPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) is typically employed for phosphoproteome analysis. Alternatively, capillary zone electrophoresis (CZE) - ESI-MS/MS has great potential for phosphoproteome analysis due to the significantly different migration times of phosphorylated and unphosphorylated forms of peptides. In this work, we systematically compared UPLC-MS/MS and CZE-MS/MS for phosphorylated peptide identifications (IDs) using an enriched phosphoproteome from the MCF-10A cell line. When the sample loading amount of UPLC was 10 times higher than that of CZE (2 μg vs. 200 ng), UPLC generated more phosphorylated peptide IDs than CZE (3,313 vs. 1,783). However, when the same sample loading amounts were used for CZE and UPLC (2–200 ng), CZE-MS/MS consistently and significantly outperformed UPLC-MS/MS in terms of phosphorylated peptide and total peptide IDs. This superior performance is most likely due to the higher peptide intensity generated by CZE-MS/MS. More importantly, compared with UPLC data from 2 μg sample, CZE-MS/MS can identify over 500 unique phosphorylated peptides from 200 ng sample, suggesting that CZE and UPLC are complementary for phosphorylated peptide IDs. With further improved loading capacity via a dynamic pH junction method, 2,313 phosphorylated peptides were identified with single-shot CZE-MS/MS in a 100 min analysis. This number of phosphorylated peptide IDs is over one order of magnitude higher than the number of phosphorylated peptide IDs previously reported by single-shot CZE-MS/MS. PMID:26399161
Miranda, Tiago A; Silva, Pedro H R; Pianetti, Gerson A; César, Isabela C
2015-01-28
Chloroquine and primaquine are the first-line treatment recommended by World Health Organization for malaria caused by Plasmodium vivax. Since the problem of counterfeit or substandard anti-malarials is well established all over the world, the development of rapid and reliable methods for quality control analysis of these drugs is essential. Thus, the aim of this study was to develop and validate a novel UPLC-DAD method for simultaneously quantifying chloroquine and primaquine in tablet formulations. The UPLC separation was carried out using a Hypersil C18 column (50 × 2.1 mm id; 1.9 μm particle size) and a mobile phase composed of acetonitrile (A) and 0.1% aqueous triethylamine, pH 3.0 adjusted with phosphoric acid (B), at a flow rate 0.6 mL/min. Gradient elution was employed. UV detection was performed at 260 nm. UPLC method was fully validated and the results were compared to a conventional HPLC-DAD method for the analysis of chloroquine and primaquine in tablet formulations. UPLC method was shown to be linear (r2 > 0.99), precise (CV < 2.0%), accurate (recovery rates from 98.11 to 99.83%), specific, and robust. No significant differences were observed between the chloroquine and primaquine contents obtained by UPLC and HPLC methods. However, UPLC method promoted faster analyses, better chromatographic performance and lower solvent consumption. The developed UPLC method was shown to be a rapid and suitable technique to quantify chloroquine and primaquine in pharmaceutical preparations and may be successfully employed for quality control analysis.
Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A.; Chen, Hao
2015-01-01
This study presents the development of ultra-performance liquid chromatography/mass spectrometry (UPLC/MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of disulfide bond-containing proteins/peptides. In our approach, a protein/peptide mixture sample undergoes fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and MS/MS analyses. The electrochemical cell is coupled to MS using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, disulfide bond-containing peptides can be differentiated from those without disulfide bonds as the former are electroactive and reducible. Tandem MS analysis of the disulfide-reduced peptide ions provides increased sequence and disulfide linkage pattern information. In a reactive DESI-MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which would be useful in top-down protein structure analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1~2 orders of magnitude by using UPLC for the LC/EC/MS platform, in comparison to the previously used high performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis. PMID:26307715
NASA Astrophysics Data System (ADS)
Dattani, Nike
For large internuclear distances, the potential energy between two atoms is known analytically, based on constants that are calculated from atomic ab initio rather than molecular ab initio. This analytic form can be built into models for molecular potentials that are fitted to spectroscopic data. Such empirical potentials constitute the most accurate molecular potentials known. For HeH+, and BeH+, the long-range form of the potential is based only on the polarizabilities for He and H respectively, for which we have included up to 4th order QED corrections. For BeH, the best ab initio potential matches all but one observed vibrational spacing to < 1 cm- accuracy, and for Li2 the discrepancy in the spacings is < 0.08 cm-1 for all vibrational levels. But experimental methods such as photoassociation require the absolute energies, not spacings, and these are still several in several cm-1 disagreement. So empirical potentials are still the only reliable way to predict energies for few-electron systems. We also give predictions for various unobserved ''halo nucleonic molecules'' containing the ''halo'' isotopes: 6,8He, 11Li, 11,14Be and 8 , 17 , 19B.
Low prevalence of juvenile-onset Behcet's disease with uveitis in East/South Asian people.
Kitaichi, N; Miyazaki, A; Stanford, M R; Iwata, D; Chams, H; Ohno, S
2009-11-01
There is little information on the demographic and clinical characteristics of Behçet's disease in children in different parts of the world. We sought to provide this information through a questionnaire survey of specialist eye centres. Descriptive questionnaires were collected from 25 eye centres in 14 countries. The questionnaire surveyed details of juvenile-onset Behçet's disease with uveitis. Ethnic groups, clinical features, treatments and prognosis of paediatric-age Behçet's disease were examined on a worldwide scale. The clinical data of 135 juvenile-onset and 1227 adult-onset patients with uveitis were collected. The average age of disease diagnosis in the children was 11.7 years old. Of the ethnic groups identified 54% were from Middle East, 43% from Europe, but only 2% from East/South Asian countries. By contrast, 19.2% of adult patients were from East or South Asia. The frequency of genital ulcers in juvenile patients was 38.7%, which was significantly lower than in adult cases (53.5%; p<0.01). Behçet's disease with uveitis was less common in children than in adults in East/South Asia. Although the clinical features of the systemic disease were similar in children and adults, there was a lower frequency of genital ulceration in children.
Interferon Alpha-2a Therapy in Patients with Refractory Behçet Uveitis.
Hasanreisoglu, Murat; Cubuk, Mehmet Ozgur; Ozdek, Sengul; Gurelik, Gokhan; Aktas, Zeynep; Hasanreisoglu, Berati
2017-02-01
To report the results of IFNα2a therapy in patients with Behçet uveitis refractory to azathioprine-cyclosporine combination treatment. In a retrospective study, 39 patients treated with either azathioprine-cyclosporine combination treatment (group 1, n = 23) or IFNα2a (group 2, n = 16) with a diagnosis of ocular Behçet disease (BD), were included in the study. Group 2 consisted of patients who did not respond to conventional combination therapy, and were therefore treated with IFNα2a. Clinical response and relapse rates were recorded for each group. The mean number of uveitis attacks/year per patient was 0.8 ± 1.6 in Group 1. In Group 2, a significant decrease in the mean number of uveitis attacks/year per patient was observed after initiation of IFNα2a (2.4 ± 1.8 vs 1.3 ± 2.0) (p<0.05). When the two groups were compared after administration of IFNα2a therapy, no statistical difference was found in terms of uveitis attack/year and attack-free intervals, with a partial response to both treatments. IFNα2a therapy is an effective alternative for Behçet uveitis patients where conventional combination therapy fails.
A novel isoflavone profiling method based on UPLC-PDA-ESI-MS.
Zhang, Shuang; Zheng, Zong-Ping; Zeng, Mao-Mao; He, Zhi-Yong; Tao, Guan-Jun; Qin, Fang; Chen, Jie
2017-03-15
A novel non-targeted isoflavone profiling method was developed using the diagnostic fragment-ion-based extension strategy, based on ultra-high performance liquid chromatography coupled with photo-diode array detector and electrospray ionization-mass spectrometry (UPLC-PDA-ESI-MS). 16 types of isoflavones were obtained in positive mode, but only 12 were obtained in negative mode due to the absence of precursor ions. Malonyldaidzin and malonylgenistin glycosylated at the 4'-O position or malonylated at the 4″-O position of glucose were indicated by their retention behavior and fragmentation pattern. Three possible quantification methods in one run based on UPLC-PDA and UPLC-ESI-MS were validated and compared, suggesting that methods based on UPLC-ESI-MS possess remarkable selectivity and sensitivity. Impermissible quantitative deviations induced by the linearity calibration with 400-fold dynamic range was observed for the first time and was recalibrated with a 20-fold dynamic range. These results suggest that isoflavones and their stereoisomers can be simultaneously determined by positive-ion UPLC-ESI-MS in soymilk. Copyright © 2016. Published by Elsevier Ltd.
Ok, Hyun Ee; Choi, Sung-Wook; Kim, Meehye; Chun, Hyang Sook
2014-11-15
High-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were compared to validate a method for determination of zearalenone (ZON) in noodles, cereal snacks, and infant formulas. The limits of detection and quantification in HPLC and UPLC were found to be 4.0 and 13.0 μg kg(-1) and 2.5 and 8.3 μg kg(-1), respectively. The average recoveries of ZON by HPLC and UPLC ranged from 79.1% to 105.3% and from 85.1% to 114.5%, respectively. The measurement uncertainties of the two methods for ZON determination were within the maximum standard uncertainty. The two methods showed that the levels of ZON in 163 naturally contaminated samples ranged from 4.3 to 8.3 μg kg(-1) by HPLC and 3.1 to 17.6 μg kg(-1) by UPLC. These findings indicate that either method is suitable for the determination of ZON in noodles, cereal snacks, and infant formulas, but UPLC gives faster results with better sensitivity. Copyright © 2014 Elsevier Ltd. All rights reserved.
Validation of an ultra-fast UPLC-UV method for the separation of antituberculosis tablets.
Nguyen, Dao T-T; Guillarme, Davy; Rudaz, Serge; Veuthey, Jean-Luc
2008-04-01
A simple method using ultra performance LC (UPLC) coupled with UV detection was developed and validated for the determination of antituberculosis drugs in combined dosage form, i. e. isoniazid (ISN), pyrazinamide (PYR) and rifampicin (RIF). Drugs were separated on a short column (2.1 mm x 50 mm) packed with 1.7 mum particles, using an elution gradient procedure. At 30 degrees C, less than 2 min was necessary for the complete separation of the three antituberculosis drugs, while the original USP method was performed in 15 min. Further improvements were obtained with the combination of UPLC and high temperature (up to 90 degrees C), namely HT-UPLC, which allows the application of higher mobile phase flow rates. Therefore, the separation of ISN, PYR and RIF was performed in less than 1 min. After validation (selectivity, trueness, precision and accuracy), both methods (UPLC and HT-UPLC) have proven suitable for the routine quality control analysis of antituberculosis drugs in combined dosage form. Additionally, a large number of samples per day can be analysed due to the short analysis times.
Sample preparation and UHPLC-FD analysis of pteridines in human urine.
Tomšíková, H; Solich, P; Nováková, L
2014-07-01
Elevated levels of pteridines can indicate the activation of cellular immune system by certain diseases. No work dealing with the simultaneous determination of urinary neopterin, biopterin and their reduced forms has been published. Therefore, a new SPE-UHPLC-FD method for the analysis of these compounds has been developed. The main emphasis was put on the stability of dihydroforms during the sample processing and storage. As a stabilizing agent, dithiothreitol, at various concentrations, and various pH values (3.8-9.8) of working solutions were tested. Chromatographic separation was performed under HILIC isocratic conditions on BEH Amide column. The method was linear for the calibration standard solutions in the range of 10-10,000 ng/ml (dihydroforms) and 0.5-1000 ng/ml (oxidized forms), and for real samples in the range of 25-1000 ng/ml (dihydroforms) and 1-100 ng/ml (oxidized forms). The development of a new SPE sample preparation method was carried out on different types of sorbents (based on a mixed-mode cation exchange, porous graphitic carbon and a polymer comprising hydrophilic and hydrophobic components). Final validation was performed on a MCAX SPE column. Method accuracy ranged from 76.9 to 121.9%. The intra- and inter-day precision did not exceed 10.7%. The method provided high sensitivity for the use in routine clinical measurements of urine (LLOQ 1 ng/ml for oxidized forms and 25 ng/ml for dihydroforms). Average concentrations of biopterin, neopterin, and dihydrobiopterin found in urine of healthy persons were related to the mol of creatinine (66.8, 142.3, and 257.3 μmol/mol of creatinine, respectively) which corresponded to the literature data. The concentration of dihydroneopterin obtained using our method was 98.8 μmol/mol of creatinine. Copyright © 2014 Elsevier B.V. All rights reserved.
Mei, Shenghui; Wang, Jiaqing; Zhu, Leting; Chen, Ruiling; Li, Xingang; Chen, Kai; Chen, Guangqiang; Zhou, Jianxin; Wang, Qiang; Zhao, Zhigang
2017-08-01
Vancomycin (VCM) is clinically used in treating patients with postoperative intracranial infections. The cerebrospinal fluid (CSF) concentration of VCM varies greatly among patients. To guide the dosage regimens, monitoring of VCM in CSF is needed. However a method for analysis of VCM in human CSF is lacking. An ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for analysis of VCM in human CSF, and the agreement of UPLC-MS/MS and chemiluminescence immunoassay (CLIA) in the analysis of CSF VCM was evaluated. The ion transitions were m/z 725.5 > 144.1 for VCM and m/z 455.2 > 308.2 for methotrexate (internal standard). The agreement between UPLC-MS/MS and CLIA was evaluated by Bland-Altman plot in 179 samples. The calibration range of the UPLC-MS/MS method was 1-400 mg/L. The inaccuracy and imprecision were -0.69-10.80% and <4.95%. The internal standard normalized recovery and matrix factor were 86.14-99.31 and 85.84-92.07%, respectively. The measurements of CLIA and UPLC-MS/MS were strongly correlated (r > 0.98). The 95% limit of agreement of the ratio of CLIA to UPLC-MS/MS was 61.66-107.40%. Further studies are warranted to confirm the results. Copyright © 2017 John Wiley & Sons, Ltd.
Li, Guoyun; Li, Lingyun; Xue, Changhu; Middleton, Dustin; Linhardt, Robert J.; Avci, Fikri Y.
2015-01-01
Pneumococcal type-3 polysaccharide (Pn3P) is considered a major target for the development of a human vaccine to protect against Streptococcus pneumonia infection. Thus, it is critical to develop methods for the preparation and analysis of Pn3P-derived oligosaccharides to better understand its immunological properties. In this paper, we profile oligosaccharides, generated by the free radical depolymerization of Pn3P, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS). Hydrophilic liquid interaction chromatography (HILIC)-mass spectrometry (MS) revealed a series of oligosaccharides with an even- and odd-number of saccharide residues, ranging from monosaccharide, degree of polymerization (dp1) to large oligosaccharides up to dp 20, generated by free radical depolymerization. Isomers of oligosaccharides with an even number of sugar residues were easily separated on a HILIC column, and their sequences could be distinguished by comparing MS/MS of these oligosaccharides and their reduced alditols. Fluorescent labeling with 2-aminoacridone (AMAC) followed by reversed phase (RP)-LC-MS/MS was applied to analyze and sequence poorly separated product mixtures, as RP-LC affords higher resolution of AMAC-labeled oligosaccharides than does HILIC-based separation. The present methodology can be potentially applied to profiling other capsular polysaccharides. PMID:25913329
Iverson, Chad D; Gu, Xinyun; Lucy, Charles A
2016-08-05
This work systematically investigates the selectivity changes on many HILIC phases from w(w)pH 3.7-6.8, at 5 and 25mM buffer concentrations. Hydrophilicity (kcytosine/kuracil) vs. ion interaction (kBTMA/kuracil) selectivity plots developed by Ibrahim et al. (J. Chromatogr. A 1260 (2012) 126-131) are used to investigate the effect of mobile phase changes on the selectivity of 18 HILIC columns from various classes. "Selectivity change plots" focus on the change in hydrophilicity and ion interaction that the columns exhibit upon changing mobile phase conditions. In general, the selectivity behavior of most HILIC columns is dominated by silanol activity. Minimal changes in selectivity are observed upon changing pH between w(w)pH 5 and 6.8. However, a reduction in ionic interaction is observed when the buffer concentration is increased at w(w)pH≥5.0 due to ionic shielding. Reduction of the w(w)pH to<5.0 results in decreasing cation exchange activity due to silanol protonation. Under all eluent conditions, the majority of phases show little change in their hydrophilicity. Copyright © 2016 Elsevier B.V. All rights reserved.
Top-down approach for the direct characterization of low molecular weight heparins using LC-FT-MS.
Li, Lingyun; Zhang, Fuming; Zaia, Joseph; Linhardt, Robert J
2012-10-16
Low molecular heparins (LMWHs) are structurally complex, heterogeneous, polydisperse, and highly negatively charged mixtures of polysaccharides. The direct characterization of LMWH is a major challenge for currently available analytical technologies. Electrospray ionization (ESI) liquid chromatography-mass spectrometry (LC-MS) is a powerful tool for the characterization complex biological samples in the fields of proteomics, metabolomics, and glycomics. LC-MS has been applied to the analysis of heparin oligosaccharides, separated by size exclusion, reversed phase ion-pairing chromatography, and chip-based amide hydrophilic interaction chromatography (HILIC). However, there have been limited applications of ESI-LC-MS for the direct characterization of intact LMWHs (top-down analysis) due to their structural complexity, low ionization efficiency, and sulfate loss. Here we present a simple and reliable HILIC-Fourier transform (FT)-ESI-MS platform to characterize and compare two currently marketed LMWH products using the top-down approach requiring no special sample preparation steps. This HILIC system relies on cross-linked diol rather than amide chemistry, affording highly resolved chromatographic separations using a relatively high percentage of acetonitrile in the mobile phase, resulting in stable and high efficiency ionization. Bioinformatics software (GlycReSoft 1.0) was used to automatically assign structures within 5-ppm mass accuracy.
Kathriarachchi, Udani L; Vidhate, Sagar S; Al-Tannak, Naser; Thomson, Alison H; da Silva Neto, Michael J J; Watson, David G
2018-07-01
A method was developed for the determination of amoxicillin and metronidazole in human serum. The procedure used was hydrophilic interaction chromatography (HILIC) followed by mass spectrometric (MS) detection. Chromatographic separation was achieved on a ZIC-HILIC column and the mobile phase consisted of a mixture of 0.1% (v/v) formic acid in water and 0.1% (v/v) formic acid in acetonitrile. The method was validated with regard to selectivity, accuracy, precision, calibration, lower limit of quantification (LOQ), extraction recovery and matrix effect. The LOQs were 0.0138 and 0.008 μg/ml for amoxicillin and metronidazole respectively, while for quantification purposes linearity was achieved in the range of 0.1 μg/ml to 6.4 μg/ml for both drugs with correlation coefficients >0.9990. The intraday precision (expressed as %RSD) and the accuracy (expressed as the % deviation from the nominal value) was <15% for both antibiotics at all QC levels. Extraction recoveries for both drugs and internal standards were >80%, while a considerable matrix effect (<60%) was observed for amoxicillin. Finally, the method was applied to the determination of amoxicillin and metronidazole concentrations in serum for 20 patients. Copyright © 2018 Elsevier B.V. All rights reserved.
Bennett, Raffeal; Olesik, Susan V
2017-04-01
Enhanced fluidity liquid chromatography using the hydrophilic interaction retention mechanism (EFLC-HILIC) is studied as an alternative separation mode for analyzing oligosaccharides and other sugars. These carbohydrates, which are important for the study of foods and biological systems, are difficult to comprehensively profile and either require a non-green, expensive solvent (i.e. acetonitrile) or derivatization of the analytes at the expense of time, sample loss, and loss of quantitative information. These difficulties arise from the diverse isomerism, mutarotation, and lack of a useable chromophore/fluorophore for spectroscopic detection. Enhanced fluidity liquid chromatography is an alternative separation method that involves the use of conventional polar solvents, such as methanol/water mixtures, as the primary mobile phase component and liquid carbon dioxide (CO 2 ) as the modifier in subcritical conditions. The addition of liquid CO 2 enhances diffusivity and decreases viscosity while maintaining mixture polarity, which typically results in reduced time of analysis and higher efficiency. This work illustrates an optimized EFLC-HILIC separation of a test mixture of oligosaccharides and simple sugars with a resolution greater than 1.3 and an analysis time decrease of over 35% compared to a conventional HPLC HILIC-mode analysis using acetonitrile/water mobile phases. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Guoyun; Li, Lingyun; Xue, Changhu; Middleton, Dustin; Linhardt, Robert J; Avci, Fikri Y
2015-06-05
Pneumococcal type-3 polysaccharide (Pn3P) is considered a major target for the development of a human vaccine to protect against Streptococcus pneumoniae infection. Thus, it is critical to develop methods for the preparation and analysis of Pn3P-derived oligosaccharides to better understand its immunological properties. In this paper, we profile oligosaccharides, generated by the free radical depolymerization of Pn3P, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS). Hydrophilic liquid interaction chromatography (HILIC)-mass spectrometry (MS) revealed a series of oligosaccharides with an even- and odd-number of saccharide residues, ranging from monosaccharide, degree of polymerization (dp1) to large oligosaccharides up to dp 20, generated by free radical depolymerization. Isomers of oligosaccharides with an even number of sugar residues were easily separated on a HILIC column, and their sequences could be distinguished by comparing MS/MS of these oligosaccharides and their reduced alditols. Fluorescent labeling with 2-aminoacridone (AMAC) followed by reversed phase (RP)-LC-MS/MS was applied to analyze and sequence poorly separated product mixtures, as RP-LC affords higher resolution of AMAC-labeled oligosaccharides than does HILIC-based separation. The present methodology can be potentially applied to profiling other capsular polysaccharides. Copyright © 2015 Elsevier B.V. All rights reserved.
Mallik, Abul K; Cheah, Wee Keat; Shingo, Kaori; Ejzaki, Aika; Takafuji, Makoto; Ihara, Hirotaka
2014-07-01
A new hydrophilic and nonionic poly(2-vinyloxazoline)-grafted silica (Sil-VOX(n)) phase was synthesized and applied for the separation of nucleosides and nucleobases in hydrophilic interaction chromatography (HILIC). Polymerization and immobilization onto silica were confirmed by using characterization techniques including (1)H NMR spectroscopy, elemental analysis, and diffuse reflectance infrared Fourier transform spectroscopy. The hydrophilicity or wettability of Sil-VOX(n) was observed by measuring the contact angle (59.9°). The chromatographic results were compared with those obtained with a conventional HILIC silica column. The Sil-VOX(n) phase showed much better separation of polar test analytes than the silica column, and the elution order was different. Differences in selectivity between these two columns indicate that the stationary phase cannot function merely as an inert support for a water layer into which the solutes are partitioned from the bulk mobile phase. To elucidate the interaction mechanism, the separation of dihydroxybenzene isomers was performed on both columns in normal-phase liquid chromatography. Sil-VOX(n) was very sensitive to the dipole moments of the positional isomers of polycyclic aromatic compounds in normal-phase liquid chromatography. The interaction mechanism for Sil-VOX(n) in HILIC separation is also described.
Zhu, Hongbin; Wang, Chunyan; Qi, Yao; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2013-01-15
A fingerprinting approach was developed by means of UPLC-ESI/MS(n) (ultra-performance liquid chromatography-electrospray ionization/mass spectrometry) for the quality control of processed Radix Aconiti, a widely used toxic traditional herbal medicine. The present fingerprinting approach was based on the two processing methods recorded in Chinese Pharmacopoeia for the purpose of reducing the toxicity and ensuring the clinical therapeutic efficacy. Similarity evaluation, hierarchical cluster analysis and principal component analysis were performed to evaluate the similarity and variation of the samples. The results showed that the well processed, unqualified processed and the raw Radix Aconiti could be clustered reasonably corresponding to the contents of their constituents. The loading plot shows that the main chemical markers having the most influence on the discrimination amongst the qualified and unqualified samples were mainly some monoester diterpenoid aconitines and diester diterpenoid aconitines. Finally, the UPLC-UV and UPLC-ESI/MS(n) characteristic fingerprints were established according to the well processed and purchased qualified samples. At the same time, a complementary quantification method of six Aconitine-type alkaloids was developed using UPLC-UV and UPLC-ESI/MS. The average recovery of the monoester diterpenoid aconitines was 95.4-99.1% and the average recovery of the diester diterpenoid aconitines was 103-112%. The proposed combined quantification method by UPLC-UV and UPLC-ESI/MS allows the samples analyzed in a wide concentration range. Therefore, the established fingerprinting approach in combination with chemometric analysis provides a flexible and reliable method for quality assessment of toxic herbal medicine. Copyright © 2012 Elsevier B.V. All rights reserved.
Marmet, Cynthia; Actis-Goretta, Lucas; Renouf, Mathieu; Giuffrida, Francesca
2014-01-01
Chlorogenic acids and derivatives like phenolic acids are potentially bioactive phenolics, which are commonly found in many foods. Once absorbed, chlorogenic and phenolic acids are highly metabolized by the intestine and the liver, producing glucuronidated and/or sulphated compounds. These metabolites were analyzed in human plasma using a validated liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method. After protein precipitation, phenolic acids and their metabolites were extracted by using ethanol and chromatographic separation was achieved by reversed-phase using an Acquity UPLC BEH C18 column combined with a gradient elution system using 1% acetic acid aqueous solution and 1% acetic acid with 100% acetonitrile. The method was able to quantify 56 different compounds including 24 phenolic acids, 4 lactones, 15 sulfates and 13 glucuronides metabolites between 5 and 1000nM in plasma for most of them, except for m-dihydrocoumaric acid, 5-ferulloylquinic-glucuronide, 4-methoxycinnamic acid, 3-phenylpropionic acid, 3-(4-methoxyphenyl)propionic acid (25 to 1000nM) and p-dihydrocoumaric acid (50-1000nM). Values of repeatability and intermediate reproducibility were below 15% of deviation in general, and maximum 20% for the lowest concentrations. The validated method was successfully applied to quantify phenolic acids and their metabolites in plasma obtained after oral ingestion of soluble coffee. In conclusion, the developed and validated method is proved to be very sensitive, accurate and precise for the quantification of these possible dietary phenols. Copyright © 2013 Elsevier B.V. All rights reserved.
Rodríguez-Gómez, R; Zafra-Gómez, A; Camino-Sánchez, F J; Ballesteros, O; Navalón, A
2014-07-04
In the present work, two specific, accurate and sensitive methods for the determination of endocrine disrupting chemicals (EDCs) in human breast milk are developed and validated. Bisphenol A and its main chlorinated derivatives, five benzophenone-UV filters and four parabens were selected as target analytes. The method involves a stir-bar sorptive extraction (SBSE) procedure followed by a solvent desorption prior to GC-MS/MS or UHPLC-MS/MS analysis. A derivatization step is also necessary when GC analysis is performed. The GC column used was a capillary HP-5MS with a run time of 26min. For UHPLC analysis, the stationary phase was a non-polar Acquity UPLC(®) BEH C18 column and the run time was 10min. In both cases, the analytes were detected and quantified using a triple quadrupole mass spectrometer (QqQ). Quality parameters such as linearity, accuracy (trueness and precision), sensitivity and selectivity were examined and yielded good results. The limits of quantification (LOQs) ranged from 0.3 to 5.0ngmL(-1) for GC and from 0.2 to 1.0ngmL(-1) for LC. The relative standard deviation (RSD) was lower than 15% and the recoveries ranged from 92 to 114% in all cases, being slightly unfavorable the results obtained with LC. The methods were satisfactorily applied for the determination of target compounds in human milk samples from 10 randomly selected women. Copyright © 2014 Elsevier B.V. All rights reserved.
Rathore, Atul S; Sathiyanarayanan, L; Deshpande, Shreekant; Mahadik, Kakasaheb R
2016-11-01
A rapid and sensitive method for the extraction and determination of four major polyphenolic components in Euphoria longana Lam. seeds is presented for the first time based on matrix solid-phase dispersion extraction followed by ultra high performance liquid chromatography with hybrid triple quadrupole linear ion trap mass spectrometry. Matrix solid-phase dispersion method was designed for the extraction of Euphoria longana seed constituents and compared with microwave-assisted extraction and ultrasonic-assisted extraction methods. An Ultra high performance liquid chromatography with hybrid triple quadrupole linear ion-trap mass spectrometry method was developed for quantitative analysis in multiple-reaction monitoring mode in negative electrospray ionization. The chromatographic separation was accomplished using an ACQUITY UPLC BEH C 18 (2.1 mm × 50 mm, 1.7 μm) column with gradient elution of 0.1% aqueous formic acid and 0.1% formic acid in acetonitrile. The developed method was validated with acceptable linearity (r 2 > 0.999), precision (RSD ≤ 2.22%) and recovery (RSD ≤ 2.35%). The results indicated that matrix solid-phase dispersion produced comparable extraction efficiency compared with other methods nevertheless was more convenient and time-saving with reduced requirements on sample and solvent volumes. The proposed method is rapid and sensitive in providing a promising alternative for extraction and comprehensive determination of active components for quality control of Euphoria longana products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Daping; Wu, Lei; Chow, Diana S-L; Tam, Vincent H; Rios, Danielle R
2016-01-05
The determination of dopamine facilitates better understanding of the complex brain disorders in the central nervous system and the regulation of endocrine system, cardiovascular functions and renal functions in the periphery. The purpose of this study was to develop a highly sensitive and reliable assay for the quantification of dopamine in human neonate plasma. Dopamine was extracted from human plasma by strong cation exchange (SCX) solid phase extraction (SPE), and subsequently derivatized with propionic anhydride. The derivatized analyte was separated by a Waters Acquity UPLC BEH C18 column using gradient elution at 0.4 ml/min with mobile phases A (0.2% formic acid in water [v/v]) and B (MeOH-ACN [v/v, 30:70]). Analysis was performed under positive electrospray ionization tandem mass spectrometer (ESI-MS/MS) in the multiple reaction monitoring (MRM) mode. The stable and relatively non-polar nature of the derivatized analyte enables reliable quantification of dopamine in the range of 10-1000 pg/ml using 200 μl of plasma sample. The method was validated with intra-day and inter-day precision less than 7%, and the intra-day and inter-day accuracy of 91.9-101.9% and 92.3-102.6%, respectively. The validated assay was applied to quantify dopamine levels in two preterm neonate plasma samples. In conclusion, a sensitive and selective LC-MS/MS method has been developed and validated, and successfully used for the determination of plasma dopamine levels in preterm neonates. Copyright © 2015 Elsevier B.V. All rights reserved.
You, Chao; Song, Lili; Xu, Baiqing; Gao, Shaopeng
2016-02-01
A method is developed for determination of levoglucosan at trace concentration levels in complex matrices of snow and ice samples. This method uses an injection mixture comprising acetonitrile and melt sample at a ratio of 50/50 (v/v). Samples are analyzed using ultra-performance liquid chromatography system combined with triple tandem quadrupole mass spectrometry (UPLC-MS/MS). Levoglucosan is analyzed on BEH Amide column (2.1 mm × 100 mm, 1.7 um), and a Z-spray electrospray ionization source is used for levoglucosan ionization. The polyether sulfone filter is selected for filtrating insoluble particles due to less impact on levoglucosan. The matrix effect is evaluated by using a standard addition method. During the method validation, limit of detection (LOD), linearity, recovery, repeatability and reproducibility were evaluated using standard addition method. The LOD of this method is 0.11 ng mL(-1). Recoveries vary from 91.2% at 0.82 ng mL(-1) to 99.3% at 4.14 ng mL(-1). Repeatability ranges from 17.9% at a concentration of 0.82 ng mL(-1) to 2.8% at 4.14 ng mL(-1). Reproducibility ranges from 15.1% at a concentration of 0.82 ng mL(-1) to 1.9% at 4.14 ng mL(-1). This method can be implemented using less than 0.50 mL sample volume in low and middle latitude regions like the Tibetan Plateau. Copyright © 2015 Elsevier B.V. All rights reserved.
Liu, Xiao-hua; Zhao, Jian-bang; Guo, Long; Yang, Ying-lai; Hu, Fang; Zhu, Rui-juan; Feng, Shi-lan
2014-09-01
A sensitive and reliable ultra-pressure liquid chromatography with tandem mass spectrometry (UPLC-MS) was developed and validated for simultaneous quantification of six main bioactive components, i.e., calycosin-7-O-β-D-glucoside, ononin, calycosin, formononetin, astragaloside IV, and astragaloside II in rat plasma after oral administration of the 95 % ethanol extraction from Radix Astragali. Plasma samples were extracted with Waters Oasis(TM) HLB 1 cc (30 mg) Extraction Cartridges (SPE) separated on an UPLC™ BEH C18 column and detected by MS with electro spray ionization interface in positive selective ion monitoring mode. Calibration curves offered linear ranges of two orders of magnitude with r (2) > 0.99. The method had the lower limit quantification of 1.30, 0.73, 1.17, 2.33, 0.63, and 0.83 ng/mL for ononin, calycosin, calycosin-7-O-β-D-glucoside, formononetin, astragaloside IV, and astragaloside II, respectively, with precision less than 10 %. The RSD of intra- and inter-day variations ranged from 1.66 to 6.46 and 3.39 to 6.58 %. This developed method was applied subsequently to pharmacokinetic studies of the six compounds in rats successfully. The proposed method was for the first time to compare the pharmacokinetic difference between calycosin-7-O-β-D-glucoside and calycosin in rat plasma, so as between ononin and formononetin, and studied to the astragaloside II pharmacokinetics in rat plasma.
[CARDIOVASCULAR INVOLVEMENTS IN BEHÇET'S DISEASE: "ANGIO-BEHÇET"].
Tridetti, J; Benoit, A; Borgoens, P; Hoffer, E
2016-01-01
Behçet's disease is a relapsing, immune-mediated systemic vasculitis that may affect blood vessels of all types and sizes. Nowadays, the etiology remains unclear. In the absence of a biological marker or pathognomonic radiology, the diagnosis is mainly based on clinical manifestations. The cardiovascular involvement, known as "angio-Behçet", is relatively common and affects up to 40% of patients. It typi- cally occurs in a young male, usually during the onset of the disease. In general, immunosuppressive and anticoagulant therapies initiated early are likely to induce a remarkable cli- nical improvement. Nevertheless, prompt recognition of the polymorphous cardiovascular manifestations of the disease is challenging and may be responsible for some considerable delay prior to initiation of adequate therapy. The aim of this article is to describe the spectrum of cardiovascular involve- ments of Behçet's disease in order to optimize detection and therapeutic management.
Gezici, Orhan; Kara, Hüseyin
2011-09-15
The stationary phase characteristics of the material obtained through immobilization of humic acid (HA) to aminopropyl silica (APS) via amide-bond formation were investigated. The material was characterized in terms of elemental analysis, FTIR, thermogravimetric analyses, pH point of zero charge measurements, potentiometric titrations, and contact angle measurements. Amount of HA bonded to APS was determined from the elemental analysis results, and found as 170 mgHA/gAPS. Stability of the material was studied in aqueous media at different pH values, and amount of HA released at pH=8 did not exceed 2% of the total immobilized HA. Stationary phase characteristics of the well-characterized material were investigated in an HPLC system by using some low-molecular weight polar compounds (i.e. some nucleosides and nucleobases) as test solutes. Effect of some experimental variables such as column conditioning, composition of mobile phase, and temperature on the chromatographic behavior of the studied compounds was studied. Role of ammonium solutions at different pH values on retentive properties of the species was also studied. Retention factors (k') versus volume percentage of organic modifier exhibited a U-curve, which was evaluated as an indication for RPLC/HILIC mixed-mode behavior of the stationary phase. Orthogonality between RPLC and HILIC modes was analyzed through geometric approach, and found as 48.5%. Base-line separation for the studied groups of compounds was achieved under each studied mode, and some differentiations were observed in elution order of the compounds depending on the HPLC mode applied. Chromatograms recorded under RPLC and HILIC modes were compared with those recorded on APS under similar conditions, and thus the influence/importance of HA immobilization process was evaluated in detail. In light of the obtained results, immobilized HA is represented as a useful stationary phase for HPLC separations. Copyright © 2011 Elsevier B.V. All rights reserved.
Koch, Wendelin; Forcisi, Sara; Lehmann, Rainer; Schmitt-Kopplin, Philippe
2014-09-26
The application of ammonia acetate buffered liquid chromatography (LC) eluents is known to concomitantly lead to ion suppression when electrospray ionization mass spectrometry (ESI-MS) detection is used. In negative ESI mode, post column infusion of 2-(2-methoxyethoxy)ethanol (2-MEE) was shown in the literature to help to compensate this adverse effect occurring in reversed phase liquid chromatography mass spectrometry (RP-LC-MS) analyses. Here a setup of direct infusion and hydrophilic interaction chromatography (HILIC) post-column infusion experiments was established in order to investigate systematically the beneficial effects of 2-MEE. We demonstrate that, 2-MEE can help to improve ESI-MS sensitivity in HILIC too and reveal analyte structure specific behaviors. Our study indicates that 2-MEE especially improves ESI response for small and polar molecules. The ESI response of stable isotope labeled amino acids spiked into biological matrices increases up to 50-fold (i.e. D5-l-glutamic acid) when post column infusion of 2-MEE is applied. A non-targeted analysis of a pooled urine sample via HILIC-ESI-QTOF-MS supports this hypothesis. In direct infusion, the combined application of an ammonia acetate buffered solution together with 2-MEE results in an improved ESI response compared to a non-buffered solution. We observed up to 60-fold increased ESI response of l-lysine. We propose this effect is putatively caused by the formation of smaller ESI droplets and stripping of positive charge from ESI droplets due to evaporation of acetic acid anions. In summary, post-column infusion of 2-MEE especially enhances ESI response of small and polar molecules. Therefore it can be regarded as a valuable add-on in targeted or non-targeted metabolomic HILIC-MS studies since this method sets a focus on this molecule category. Copyright © 2014 Elsevier B.V. All rights reserved.
Investigating the stability of gadolinium based contrast agents towards UV radiation.
Birka, Marvin; Roscher, Jörg; Holtkamp, Michael; Sperling, Michael; Karst, Uwe
2016-03-15
Since the 1980s, the broad application of gadolinium(Gd)-based contrast agents for magnetic resonance imaging (MRI) has led to significantly increased concentrations of Gd in the aqueous environment. Little is known about the stability of these highly polar xenobiotics under environmental conditions, in wastewater and in drinking water treatment. Therefore, the stability of frequently applied Gd-based MRI contrast agents towards UV radiation was investigated. The hyphenation of hydrophilic interaction liquid chromatography (HILIC) with inductively coupled plasma mass spectrometry (ICP-MS) and of HILIC with electrospray ionization mass spectrometry (ESI-MS) provided quantitative elemental information as well as structural information. The contrast agents Gd-DTPA, Gd-DOTA and Gd-BT-DO3A showed a high stability in irradiation experiments applying a wavelength range from 220 nm to 500 nm. Nevertheless, the degradation of Gd-BOPTA as well as the formation of Gd-containing transformation products was observed by means of HILIC-ICP-MS. Matrix-dependent irradiation experiments showed a degradation of Gd-BOPTA down to 3% of the initial amount in purified water after 300 min, whereas the degradation was slowed down in drinking water and surface water. Furthermore, it was observed that the sum of species continuously decreased with proceeding irradiation in all matrices. After irradiation in purified water for 300 min only 16% of the sum of species was left. This indicates a release of Gd(III) ions from the complex in course of irradiation. HILIC-ESI-MS measurements revealed that the transformation products mostly resulted from O-dealkylation and N-dealkylation reactions. In good correlation with retention times, the majority of transformation products were found to be more polar than Gd-BOPTA itself. Based on accurate masses, sum formulas were obtained and structures could be proposed. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tyrosine Phosphorylation of Botulinum Neurotoxin Protease Domains
2012-06-01
trifluoroacetic acid; Tm: melting temperature; TMB, 3,3′,5,5′-tetramethylbenzidine; UPLC , ultra performance liquid chromatography; VAMP, vesicle...activity determination by UPLC . Alternately, in large-scale preparations, phosphoryla- tion reaction was stopped by removing the Src with sepharose beads...peptides. ENZYMATIC ACTIVITY ASSAYS Activity assays were based on UPLC separation and measurement of the cleaved products from a 17-residue SNAP-25
Wechsler, Bertrand; Du-Boutin, Lê Thi Huong; Amoura, Zahir
2005-02-15
Behçet's disease is a vasculitis of unknown origine. Mucocutaneous manifestations are necessary for diagnosis. Ocular and neurological involvements can lead to severe impairment. Arterial involvement may be lethal. Treatment is only symptomatic using steroids, colchicine and antiaggregant therapy. Immunosuppressive drugs are generally given for severe manifestations resistant to conventional therapy. Alpha interferon and infliximab are interesting in case of failure or relapses despite treatment. As in all chronic diseases, education and good observance are needed to improve prognosis.
Petit, A; Dadzie, O E
2013-10-01
We present an overview of the association between ethnicity and the clinical and epidemiological aspects of four multisystemic diseases: lupus erythematosus, systemic sclerosis, sarcoidosis and Behçet disease. In particular, we highlight observed ethnic differences in cutaneous manifestations of these diseases. This article should help guide clinical management, as well as serve to highlight future areas for research. © 2013 The Authors BJD © 2013 British Association of Dermatologists.
The role of infections in Behçet disease and neuro-Behçet syndrome.
Marta, Monica; Santos, Ernestina; Coutinho, Ester; Silva, Ana Martins; Correia, João; Vasconcelos, Carlos; Giovannoni, Gavin
2015-07-01
Infections are considered an environmental trigger for exacerbations of immune-mediated diseases. We aimed to establish if common viral infections could be identified as a precipitant of Behçet disease (BD) with or without neurological involvement and to assess the variability of the immune response to common viruses. We also investigated whether cytokines and chemokines could be markers of neurological involvement. Finally, we explored if anti-basal ganglia antibodies (ABGAs) would be associated with neurological involvement in BD. Our study included 14 individuals with BD with neurological involvement (neuroBehçet syndrome - NBS), 16 individuals with BD without neurological involvement and 18 healthy controls (HC). Overall we found a tendency for increased levels of anti-viral IgG antibody levels in BD, more evident in NBS patients versus HC. Epstein-Barr viral-capsid antigen IgG titres were increased in NBS patients versus other BD patients (p=0.032). Anti-measles antibody titres induced by vaccination were similarly elevated. ABGAs were not detected in the serum of our cohort. Raised levels of serum IL-8 in some BD patients did not reflect clinical activity or severity. In conclusion, there was evidence for a polyclonal immune activation rather than a specific virus effect in the sera of individuals with BD or NBS. Copyright © 2015 Elsevier B.V. All rights reserved.
Brassinosteroid biosynthesis and signalling in Petunia hybrida.
Verhoef, Nathalie; Yokota, Takao; Shibata, Kyomi; de Boer, Gert-Jan; Gerats, Tom; Vandenbussche, Michiel; Koes, Ronald; Souer, Erik
2013-05-01
Brassinosteroids (BRs) are steroidal plant hormones that play an important role in the growth and development of plants. The biosynthesis of sterols and BRs as well as the signalling cascade they induce in plants have been elucidated largely through metabolic studies and the analysis of mutants in Arabidopsis and rice. Only fragmentary details about BR signalling in other plant species are known. Here a forward genetics strategy was used in Petunia hybrida, by which 19 families with phenotypic alterations typical for BR deficiency mutants were identified. In all mutants, the endogenous BR levels were severely reduced. In seven families, the tagged genes were revealed as the petunia BR biosynthesis genes CYP90A1 and CYP85A1 and the BR receptor gene BRI1. In addition, several homologues of key regulators of the BR signalling pathway were cloned from petunia based on homology with their Arabidopsis counterparts, including the BRI1 receptor, a member of the BES1/BZR1 transcription factor family (PhBEH2), and two GSK3-like kinases (PSK8 and PSK9). PhBEH2 was shown to interact with PSK8 and 14-3-3 proteins in yeast, revealing similar interactions to those during BR signalling in Arabidopsis. Interestingly, PhBEH2 also interacted with proteins implicated in other signalling pathways. This suggests that PhBEH2 might function as an important hub in the cross-talk between diverse signalling pathways.
Nanoscale Morphology of PTB7 Based Organic Photovoltaics as a Function of Fullerene Size
Roehling, John D.; Baran, Derya; Sit, Joseph; ...
2016-08-08
High efficiency polymer:fullerene photovoltaic device layers self-assemble with hierarchical features from ångströms to 100’s of nanometers. The feature size, shape, composition, orientation, and order all contribute to device efficiency and are simultaneously difficult to study due to poor contrast between carbon based materials. This study seeks to increase device efficiency and simplify morphology measurements by replacing the typical fullerene acceptor with endohedral fullerene Lu 3N@PC 80BEH. The metal atoms give excellent scattering contrast for electron beam and x-ray experiments. Additionally, Lu 3N@PC 80BEH has a lower electron affinity than standard fullerenes, which can raise the open circuit voltage of photovoltaicmore » devices. Electron microscopy techniques are used to produce a detailed account of morphology evolution in mixtures of Lu 3N@PC 80BEH with the record breaking donor polymer, PTB7 and coated using solvent mixtures. We demonstrate that common solvent additives like 1,8-diiodooctane or chloronapthalene do not improve the morphology of endohedral fullerene devices as expected. The poor device performance is attributed to the lack of mutual miscibility between this particular polymer:fullerene combination and to co-crystallization of Lu 3N@PC 80BEH with 1,8-diiodooctane. This negative result explains why solvent additives mixtures are not necessarily a morphology cure-all.« less
Nanoscale Morphology of PTB7 Based Organic Photovoltaics as a Function of Fullerene Size
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roehling, John D.; Baran, Derya; Sit, Joseph
High efficiency polymer:fullerene photovoltaic device layers self-assemble with hierarchical features from ångströms to 100’s of nanometers. The feature size, shape, composition, orientation, and order all contribute to device efficiency and are simultaneously difficult to study due to poor contrast between carbon based materials. This study seeks to increase device efficiency and simplify morphology measurements by replacing the typical fullerene acceptor with endohedral fullerene Lu 3N@PC 80BEH. The metal atoms give excellent scattering contrast for electron beam and x-ray experiments. Additionally, Lu 3N@PC 80BEH has a lower electron affinity than standard fullerenes, which can raise the open circuit voltage of photovoltaicmore » devices. Electron microscopy techniques are used to produce a detailed account of morphology evolution in mixtures of Lu 3N@PC 80BEH with the record breaking donor polymer, PTB7 and coated using solvent mixtures. We demonstrate that common solvent additives like 1,8-diiodooctane or chloronapthalene do not improve the morphology of endohedral fullerene devices as expected. The poor device performance is attributed to the lack of mutual miscibility between this particular polymer:fullerene combination and to co-crystallization of Lu 3N@PC 80BEH with 1,8-diiodooctane. This negative result explains why solvent additives mixtures are not necessarily a morphology cure-all.« less
Chang, H K; Lee, S S; Bai, H J; Lee, Y W; Yoon, B Y; Lee, C H; Lee, Y H; Song, G G; Chung, W T; Lee, S W; Choe, J Y; Kim, C G; Chang, D K
2004-01-01
Recently we have proposed a modified set of criteria to settle the questions raised regarding the International Study Group (ISG) criteria for Behçet's disease (BD). The aim of the present study was to validate the two pre-existing criteria sets commonly used in Korea, the ISG criteria and the criteria of the Behçet's Disease Research Committee of Japan (Japanese criteria), as well as the proposed modified criteria. The study population included 155 consecutive patients with BD and 170 controls with non-Behçet's rheumatic diseases. Detailed data for all of the subjects were recorded prospectively by the participating physicians on a standard form that listed the clinical features of BD. The sensitivity, specificity, and accuracy of each set of the criteria were measured. Of the three criteria sets employed, the modified criteria were the most accurate, with an accuracy of 96.3%. The ISG criteria often failed to classify the following patients with BD: patients with only oral and genital ulcerations, certain patients with intestinal ulcerations, patients who did not manifest oral ulcerations, and patients with acute disease but fewer than three recurrent oral ulceration relapses in a 1-year period. The Japanese criteria also failed to categorize the following patients with BD: patients with oral and genital ulcerations, and patients with oral ulcerations, skin lesions, and a positive pathergy reaction. In addition, the Japanese criteria misclassified some of the control subjects with non-Behçet's uveitis as having BD. The results of this study suggest that there are some points that need to be reconsidered in the clinical application of the two pre-existing sets of criteria. Although the modified criteria were the most accurate, further validation studies will be required in other ethnic populations.
Sibley, Cailin; Yazici, Yusuf; Tascilar, Koray; Khan, Nafiz; Bata, Yasmin; Yazici, Hasan; Goldbach-Mansky, Raphaela; Hatemi, Gulen
2015-01-01
Objective To compare clinical manifestations and activity of Behçet syndrome (BS) in the United States versus Turkey using validated outcome measures. Methods Consecutive patients with BS from the US National Institutes of Health (NIH), New York University, and the University of Istanbul were evaluated. Disease activity was measured using the Behçet’s Syndrome Activity Scale (BSAS) and the Behçet’s Disease Current Activity Form (BDCAF) with quality of life measured by the Behçet Disease Quality of Life (BDQOL) form. One-way ANOVA, t-tests, and multivariate regression analyses were performed. Results Mean age did not differ between sites; however, more women were seen in the United States versus in Turkey (p < 0.001), and disease duration was longer in the United States (p = 0.02). Organ manifestations were similar for oral and genital ulcers, skin disease, arthralgia, eye disease, and thrombosis. However, more gastrointestinal (p < 0.001) and neurologic disease (p = 0.003) was seen in the United States. BSAS and BDCAF scores were worse in the United States compared to Turkey (p = 0.013 and < 0.001, respectively). Worse mean BDQOL scores were observed at the NIH compared to Istanbul (not significant). Multivariable regression models showed worse scores in ethnically atypical patients for BSAS and BDCAF (p = 0.04 and p = 0.001), American patients for BDCAF (p = 0.01), older age for BDCAF (p = 0.005), and women for BDQOL (p = 0.01). Conclusion Demographic and clinical manifestations of BS differ between sites with higher disease activity in the United States compared to Turkey. Referral patterns, age, sex, ethnicity, and country of origin may be important in these differences. These observations raise the question of whether pathogenic mechanisms differ in Turkish and American patients. PMID:24931953
Experimental investigations of recent anomalous results in superconductivity
NASA Astrophysics Data System (ADS)
Souw, Victor K.
2000-12-01
This thesis examines three recent anomalous results associated with irreversibility in type-II superconductivity: (1) The magnetic properties of the predicted superconductors LiBeH3 and Li2BeH 4, (2) the paramagnetic transition near T = Tc in Nb, and (3) a noise transition in a YBa2Cu3O7-delta thin film near the vortex-solid transition. The investigation of Li 2BeH4 and LiBeH3 was prompted by theoretical predictions of room-temperature superconductivity for Li2BeH4 and LiBeH3 and a recent report that Li2BeH4 showed magnetic irreversibilities similar to those of type-II superconductors. A modified experimental method is introduced in order to avoid artifacts due to background signals. The resulting data is suggestive of a superparamagnetic impurity from one of the reagents used in the synthesis and after subtracting this contribution, the temperature-dependent susceptibilities of Li2 BeH4 and LiBeH3 are estimated. However, no magnetic irreversibility suggestive of superconductivity is observed. The anomalous paramagnetic transition in Nb is intriguing because Nb does not share the d-wave order parameter symmetry often invoked to explain the phenomenon in other superconductors. A modified experimental method was developed in order to avoid instrumental artifacts known to produce a similar apparently paramagnetic response, but the results of this method indicate that the paramagnetic response is a physical property of the sample. Finally, a very sharp noise transition in a YBa2Cu3O7-delta thin film was found to be distinct from previously reported features in the voltage noise commonly associated with vortex fluctuations near the irreversibility line. In each of these three cases the examination of experimental techniques is an integral part of the investigation of novel vortex behavior near the onset of irreversibility.
Altiner, Ahmet; Mandal, Rajni
2010-11-15
We present a 34-year-old man with a two-year history of aphthous stomatitis, who later developed painful, erythematous nodules on his lower extremities. A pathergy test was positive, and the diagnosis of Behçet syndrome (BS) was made. It is important for the dermatologist to recognize the wide variety of cutaneous manifestations of this disorder. A pathergy test is a simple diagnostic tool that may assist in making a diagnosis. Case reports of other unusual skin manifestations in BS also are reviewed.
Lipid Storage Myopathy in Behçet's Disease: A Rare Cause of Elevated Serum Creatine Kinases Levels
Yilmaz, Sedat; Cinar, Muhammet; Karslioglu, Yıldırım; Simsek, Ismail; Erdem, Hakan; Pay, Salih; Dinc, Ayhan
2012-01-01
Muscular involvement in Behçet's disease is rare and there are only a few case reports in the literature. The causes of elevated muscle enzymes in a patient with Behcet's disease are many, including myositis, drug-induced myopathy, metabolic myopathy, and the disease itself. We herein have defined an algorithmic approach to a patient with Behcet's disease and elevated muscle enzymes and report a case of coexisting of lipid storage myopathy. PMID:22937450
Chen, Chu; Xue, Ying; Li, Qing-Miao; Wu, Yan; Liang, Jian; Qing, Lin-Sen
2018-04-01
Amorfrutins with a 2-hydroxybenzoic acid core structure are promising natural PPARγ agonists with potent antidiabetic activity. Owing to the complex matrix and low concentration in botanical material, the identification of unknown amorfrutins remains a challenge. In the present study, a combined application of UPLC-Q-TOF-MS and UPLC-QqQ-MS was developed to discover unknown amorfrutins from fruits of Amorpha fruticosa. First, reference compounds of amorfrutin A (AA), amorfrutin B (AB), and 2-carboxy-3,5-dihydroxy-4-geranylbibenzyl (AC) were analyzed using UPLC-Q-TOF-MS to reveal the characteristic fragment ions and the possible neutral loss. Second, the extract of A. fruticosa was separated and screened by UPLC-QqQ-MS using neutral loss scan to find out suspect compounds associated with the specified neutral fragment Δm/z 44. Third, the extract was re-analyzed by UPLC-Q-TOF-MS to obtain the exact mass of quasi-molecular ion and fragment ions of each suspect compound, and to subsequently calculate their corresponding molecular formulas. Finally, according to the molecular formula of suspect compound and its fragment ions and comparing with literature data, structure elucidation of four unidentified amorfrutins was achieved. The results indicated that the combination of QqQ-MS neutral loss scan and Q-TOF-MS molecular formula calculation was proven to be a powerful tool for unknown natural product identification, and this strategy provides an effective solution to discover natural products or metabolites of trace content. Graphical Abstract ᅟ.
Zhou, Fei; Zhao, Yajing; Peng, Jiyu; Jiang, Yirong; Li, Maiquan; Jiang, Yuan; Lu, Baiyi
2017-07-01
Osmanthus fragrans flowers are used as folk medicine and additives for teas, beverages and foods. The metabolites of O. fragrans flowers from different geographical origins were inconsistent in some extent. Chromatography and mass spectrometry combined with multivariable analysis methods provides an approach for discriminating the origin of O. fragrans flowers. To discriminate the Osmanthus fragrans var. thunbergii flowers from different origins with the identified metabolites. GC-MS and UPLC-PDA were conducted to analyse the metabolites in O. fragrans var. thunbergii flowers (in total 150 samples). Principal component analysis (PCA), soft independent modelling of class analogy analysis (SIMCA) and random forest (RF) analysis were applied to group the GC-MS and UPLC-PDA data. GC-MS identified 32 compounds common to all samples while UPLC-PDA/QTOF-MS identified 16 common compounds. PCA of the UPLC-PDA data generated a better clustering than PCA of the GC-MS data. Ten metabolites (six from GC-MS and four from UPLC-PDA) were selected as effective compounds for discrimination by PCA loadings. SIMCA and RF analysis were used to build classification models, and the RF model, based on the four effective compounds (caffeic acid derivative, acteoside, ligustroside and compound 15), yielded better results with the classification rate of 100% in the calibration set and 97.8% in the prediction set. GC-MS and UPLC-PDA combined with multivariable analysis methods can discriminate the origin of Osmanthus fragrans var. thunbergii flowers. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Integration of electrochemistry with ultra-performance liquid chromatography/mass spectrometry.
Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A; Chen, Hao
2015-01-01
This study presents the development of ultra-performance liquid chromatography (UPLC) mass spectrometry (MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of proteins/peptides that contain disulfide bonds. In our approach, a protein/peptide mixture sample undergoes a fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and tandem mass spectrometry (MS/MS) analyses. The electrochemical cell is coupled to the mass spectrometer using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, peptides that contain disulfide bonds can be differentiated from those without disulfide bonds, as the former are electroactive and reducible. MS/MS analysis of the disulfide-reduced peptide ions provides increased information on the sequence and disulfide-linkage pattern. In a reactive DESI- MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which will be useful in top- down protein structure MS analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1(~)2 orders of magnitude by using UPLC for the liquid chromatography (LC)/EC/MS platform, in comparison to the previously used high- performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion, and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis.
NASA Astrophysics Data System (ADS)
Chen, Chu; Xue, Ying; Li, Qing-Miao; Wu, Yan; Liang, Jian; Qing, Lin-Sen
2018-02-01
Amorfrutins with a 2-hydroxybenzoic acid core structure are promising natural PPARγ agonists with potent antidiabetic activity. Owing to the complex matrix and low concentration in botanical material, the identification of unknown amorfrutins remains a challenge. In the present study, a combined application of UPLC-Q-TOF-MS and UPLC-QqQ-MS was developed to discover unknown amorfrutins from fruits of Amorpha fruticosa. First, reference compounds of amorfrutin A (AA), amorfrutin B (AB), and 2-carboxy-3,5-dihydroxy-4-geranylbibenzyl (AC) were analyzed using UPLC-Q-TOF-MS to reveal the characteristic fragment ions and the possible neutral loss. Second, the extract of A. fruticosa was separated and screened by UPLC-QqQ-MS using neutral loss scan to find out suspect compounds associated with the specified neutral fragment Δm/z 44. Third, the extract was re-analyzed by UPLC-Q-TOF-MS to obtain the exact mass of quasi-molecular ion and fragment ions of each suspect compound, and to subsequently calculate their corresponding molecular formulas. Finally, according to the molecular formula of suspect compound and its fragment ions and comparing with literature data, structure elucidation of four unidentified amorfrutins was achieved. The results indicated that the combination of QqQ-MS neutral loss scan and Q-TOF-MS molecular formula calculation was proven to be a powerful tool for unknown natural product identification, and this strategy provides an effective solution to discover natural products or metabolites of trace content.
Yu, Kate; Little, David; Plumb, Rob; Smith, Brian
2006-01-01
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. Copyright 2006 John Wiley & Sons, Ltd.
Cho, Yuko; Tsuchiya, Shigeki; Yoshioka, Renpei; Omura, Takuo; Konoki, Keiichi; Oshima, Yasukatsu; Yotsu-Yamashita, Mari
2016-11-25
Hydrophilic-interaction chromatography (HILIC) is reportedly useful for the analysis of saxitoxin (STX) analogues, collectively known as paralytic shellfish toxins. Column switching and two-step gradient elution using HILIC combined with mass spectrometry enabled the simultaneous analysis of the 15 primary STX analogues and their biosynthetic intermediates, arginine, Int-A', and Int-C'2, and the shunt product, Cyclic-C'. Crude extracts of toxin-producing dinoflagellates can be injected without any treatment except filtration. Enrichment of the compounds using this method was highly reproducible with respect to retention times (% RSD was under 1%) and highly sensitive (limits of detection (LODs) were in the range 0.9 (Int-C'2) - 116 (C3) μM) in terms of avoiding matrix effects associated with co-eluting substances. Validation studies demonstrated acceptable performance of this method for specificity, repeatability, linearity and recovery. A comparison of the quantitative results for STX analogues in Alexandrium tamarense using HPLC with post-column fluorescent derivatization and the column-switching HILIC-MS method revealed good agreement. The presence of Int-A', Int-C'2, and Cyclic-C' in toxic dinoflagellate species with different toxin profiles was confirmed using this method. Our data support the hypothesis that the early stages of the STX biosynthesis and shunt pathways are the same in dinoflagellates and cyanobacteria. Copyright © 2016 Elsevier B.V. All rights reserved.
Simultaneous determination of metformin and vildagliptin in human plasma by a HILIC-MS/MS method.
Pontarolo, Roberto; Gimenez, Ana Carolina; de Francisco, Thais Martins Guimarães; Ribeiro, Rômulo Pereira; Pontes, Flávia Lada Degaut; Gasparetto, João Cleverson
2014-08-15
The objective of this work was to develop and validate a HILIC-MS/MS method for the simultaneous determination of metformin and vildagliptin in human plasma. Chromatographic separation was achieved using an Atlantis HILIC Silica 150-mm × 2.1-mm, 3-μm particle size column maintained at 40°C. The isocratic mobile phase consisted of 20% water and 80% acetonitrile/water solution 95:5 (v/v), containing both 0.1% formic acid and 3mM ammonium formate. The flow rate was maintained at 400 μL min(-1). Data from validation studies demonstrated that the new method is highly selective, sensitive (limits of detection <1.5 ng mL(-1)) and free of matrix and residual effects. The new method was also precise (RSD<9.0%), accurate (RE<11.2%) and linear (r ≥ 0.99) over the ranges of 5-500 ng mL(-1) for each compound. The developed method was successfully applied to determine metformin and vildagliptin in plasma volunteers who orally received a single dose of metformin (850 mg), vildagliptin (50mg) or drug association (metformin 850 mg+vildagliptin 50mg). The new method can thus also be used as a tool for the clinical monitoring of metformin and vildagliptin. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Qing; Long, Yao; Yao, Lin; Xu, Li; Shi, Zhi-Guo; Xu, Lanying
2016-01-01
A mixed-mode chromatographic stationary phase, C18-DTT (dithiothreitol) silica (SiO2) was prepared through "thiol-ene" click chemistry. The obtained material was characterized by fourier transform infrared spectroscope, nitrogen adsorption analysis and contact angle analysis. Chromatographic performance of the C18-DTT was systemically evaluated by studying the effect of acetonitrile content, pH, buffer concentration of the mobile phase and column temperature. It was demonstrated that the novel stationary phase possessed reversed phase liquid chromatography (RPLC)/hydrophilic interaction liquid chromatography (HILIC) mixed-mode property. The stop-flow test revealed that C18-DTT exhibited excellent compatibility with 100% aqueous mobile phase. Additionally, the stability and column-to-column reproducibility of the C18-DTT material were satisfactory, with relative standard deviations of retention factor of the tested analytes (verapamil, fenbufen, guanine, tetrandrine and nicotinic acid) in the range of 1.82-3.72% and 0.85-1.93%, respectively. Finally, the application of C18-DTT column was demonstrated in the separation of non-steroidal anti-inflammatory drugs, aromatic carboxylic acids, alkaloids, nucleo-analytes and polycyclic aromatic hydrocarbons. It had great resolving power in the analysis of various compounds in HILIC and RPLC chromatographic conditions and was a promising RPLC/HILIC mixed-mode stationary phase. Copyright © 2015 Elsevier B.V. All rights reserved.
Ushimaru, Kazunori; Hamano, Yoshimitsu; Katano, Hajime
2017-04-10
ε-Poly-l-lysine (ε-PL) is one of the few homopoly(amino-acid)s occurring in nature. ε-PL, which possesses multiple amino groups, is highly soluble in water, where it forms the antimicrobial polycationic chain (PL n+ ). Although the high water-solubility is advantageous for the use of ε-PL as a food preservative, it has limited the applicability of ε-PL as a biopolymer plastic. Here, we report on the preparation and availability of a water-insoluble complex formed with PL n+ and an anionic surfactant, bis(2-ethylhexyl) sulfosuccinate (BEHS - , is also commercialized as AOT) anion. The PL n+ /BEHS - -complex, which is soluble in organic solvents, was successfully used as a coating material for a cellulose acetate membrane to create a water-resistant antimicrobial membrane. In addition, the thermoplastic PL n+ /BEHS - -complex was able to be uniformly mixed with polypropylene by heating, resulting in materials exhibiting antimicrobial activities.
Behçet disease in Western Algeria.
Ghembaza, M E A; Bouabdallah, N; Lounici, A
2017-02-01
The aim of the current study was to describe the epidemiological and clinical features of Behçet disease in western Algeria. This observational retrospective study examined records for patients with Behçet disease seen in our department from 1990 to 2015. Of the 61 patients included in the study, 80.3% were men, for a sex ratio of 4.08. The mean age at onset was 27.2±7 years, and the mean interval between the onset of symptoms and diagnosis was 4.8±6.3 years. Dermatologic manifestations were the most common finding. Oral ulcers were seen in all patients, genital ulcers in 60%, pseudofolliculitis in 56.4%, and erythema nodosum in 13.5%. A pathergy test was positive in 20% of the patients. The frequencies of the remaining manifestations were as follows: joint involvement 50%, ocular involvement 71.2%, vascular complications 29.6%, neurological involvement 19%, and gastrointestinal complications 7.5%. Besides dermatological manifestations, ocular and vascular complications were the most common features observed in our patients.
Neurological manifestations of Behçet's disease: Case report and literature review.
López Bravo, Alba; Parra Soto, Carlos; Bellosta Diago, Elena; Cecilio Irazola, Álvaro; Santos-Lasaosa, Sonia
2017-05-22
Neurological involvement in Behçet's disease is rare, especially at the onset. It can present in the form of parenchymal changes or as damage to the vascular structures in its nonparenchymal form. The coexistence of both kinds of manifestations in the same patient is exceptional. We report the case of a 32-year-old patient with a history of deep venous thrombosis, who was being treated for holocranial headache, apathy, and oral and genital ulcers. Brain magnetic resonance imaging showed hyperintense lesions in the basal ganglia and white matter, and the vascular study evidenced venous thrombosis of the left transverse sinus. After confirming the diagnosis of Behçet's disease with parenchymal and nonparenchymal cerebral involvement, immunosuppressive and corticosteroid therapy was started, resulting in the remission of the symptoms. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.
Quantitation of sweet steviol glycosides by means of a HILIC-MS/MS-SIDA approach.
Well, Caroline; Frank, Oliver; Hofmann, Thomas
2013-11-27
Meeting the rising consumer demand for natural food ingredients, steviol glycosides, the sweet principle of Stevia rebaudiana Bertoni (Bertoni), have recently been approved as food additives in the European Union. As regulatory constraints require sensitive methods to analyze the sweet-tasting steviol glycosides in foods and beverages, a HILIC-MS/MS method was developed enabling the accurate and reliable quantitation of the major steviol glycosides stevioside, rebaudiosides A-F, steviolbioside, rubusoside, and dulcoside A by using the corresponding deuterated 16,17-dihydrosteviol glycosides as suitable internal standards. This quantitation not only enables the analysis of the individual steviol glycosides in foods and beverages but also can support the optimization of breeding and postharvest downstream processing of Stevia plants to produce preferentially sweet and least bitter tasting Stevia extracts.
NASA Astrophysics Data System (ADS)
Badgett, Majors J.; Boyes, Barry; Orlando, Ron
2017-05-01
Peptides with deamidated asparagine residues and oxidized methionine residues are often not resolved sufficiently to allow quantitation of their native and modified forms using reversed phase (RP) chromatography. The accurate quantitation of these modifications is vital in protein biotherapeutic analysis because they can affect a protein's function, activity, and stability. We demonstrate here that hydrophilic interaction liquid chromatography (HILIC) adequately and predictably separates peptides with these modifications from their native counterparts. Furthermore, coefficients describing the extent of the hydrophilicity of these modifications have been derived and were incorporated into a previously made peptide retention prediction model that is capable of predicting the retention times of peptides with and without these modifications.
Badgett, Majors J; Boyes, Barry; Orlando, Ron
2017-05-01
Peptides with deamidated asparagine residues and oxidized methionine residues are often not resolved sufficiently to allow quantitation of their native and modified forms using reversed phase (RP) chromatography. The accurate quantitation of these modifications is vital in protein biotherapeutic analysis because they can affect a protein's function, activity, and stability. We demonstrate here that hydrophilic interaction liquid chromatography (HILIC) adequately and predictably separates peptides with these modifications from their native counterparts. Furthermore, coefficients describing the extent of the hydrophilicity of these modifications have been derived and were incorporated into a previously made peptide retention prediction model that is capable of predicting the retention times of peptides with and without these modifications. Graphical Abstract ᅟ.
Buyuktas, Deram; Hatemi, Gulen; Yuksel-Findikoglu, Sukran; Ugurlu, Serdal; Yazici, Hasan; Yurdakul, Sebahattin
2015-01-01
Fatigue is an important problem in inflammatory diseases and affects the quality of life (QoL). We aimed to evaluate the severity and impact of fatigue in Behçet's syndrome (BS) and to determine its association with type of organ involvement and gender. One hundred and fifty-two BS, 51 rheumatoid arthritis (RA), 51 systemic lupus erythematosus (SLE), 51 ankylosing spondylitis (AS) patients and 65 healthy controls were evaluated by the fatigue severity scale, fatigue impact scale, fibromyalgia impact questionnaire (FIQ), RAPID3, SF-36 and Behçet's syndrome activity scale (the latter only in BS patients). We also analysed subgroups of BS patients with predominantly eye, vascular, joint and mucocutaneous involvement and did an additional gender analysis. Fatigue severity and fatigue impact scores were similar among BS, RA, SLE and AS patients and significantly higher than that in healthy controls (F4df=8.51; p<0.001 and F4df=8.67; p<0.001, respectively). The fatigue severity and fatigue impact scores were similarly high in BS subgroups with different types of organ involvement, and in both genders. Fatigue is an important problem in BS, as it is in other inflammatory conditions. It is similarly severe in subgroups of patients with eye, vascular, joint and mucocutaneous involvement and in either gender. Fatigue is a candidate outcome measure for clinical trials, to assess the life impact of Behçet's syndrome.
Brassinosteroid biosynthesis and signalling in Petunia hybrida
Verhoef, Nathalie; Yokota, Takao; Shibata, Kyomi; de Boer, Gert-Jan; Gerats, Tom; Vandenbussche, Michiel; Koes, Ronald; Souer, Erik
2013-01-01
Brassinosteroids (BRs) are steroidal plant hormones that play an important role in the growth and development of plants. The biosynthesis of sterols and BRs as well as the signalling cascade they induce in plants have been elucidated largely through metabolic studies and the analysis of mutants in Arabidopsis and rice. Only fragmentary details about BR signalling in other plant species are known. Here a forward genetics strategy was used in Petunia hybrida, by which 19 families with phenotypic alterations typical for BR deficiency mutants were identified. In all mutants, the endogenous BR levels were severely reduced. In seven families, the tagged genes were revealed as the petunia BR biosynthesis genes CYP90A1 and CYP85A1 and the BR receptor gene BRI1. In addition, several homologues of key regulators of the BR signalling pathway were cloned from petunia based on homology with their Arabidopsis counterparts, including the BRI1 receptor, a member of the BES1/BZR1 transcription factor family (PhBEH2), and two GSK3-like kinases (PSK8 and PSK9). PhBEH2 was shown to interact with PSK8 and 14-3-3 proteins in yeast, revealing similar interactions to those during BR signalling in Arabidopsis. Interestingly, PhBEH2 also interacted with proteins implicated in other signalling pathways. This suggests that PhBEH2 might function as an important hub in the cross-talk between diverse signalling pathways. PMID:23599276
Martín-Sómer, Ana; Mó, Otilia; Yáñez, Manuel; Guillemin, Jean-Claude
2015-01-21
The intrinsic acidity of CH2[double bond, length as m-dash]CHXH2, HC[triple bond, length as m-dash]CXH2 (X = N, P, As, Sb) derivatives and of their complexes with BeH2 and BH3 has been investigated by means of high-level density functional theory and molecular orbital ab initio calculations, using as a reference the ethyl saturated analogues. The acidity of the free systems steadily increases down the group for the three series of derivatives, ethyl, vinyl and ethynyl. The association with both beryllium dihydride and borane leads to a very significant acidity enhancement, being larger for BeH2 than for BH3 complexes. This acidity enhancement, for the unsaturated compounds, is accompanied by a change in the acidity trends down the group, which do not steadily decrease but present a minimum value for both the vinyl- and the ethynyl-phosphine. When the molecule acting as the Lewis acid is beryllium dihydride, the π-type complexes in which the BeH2 molecules interact with the double or triple bond are found, in some cases, to be more stable, in terms of free energies, than the conventional complexes in which the attachment takes place at the heteroatom, X. The most important finding, however, is that P, As, and Sb ethynyl complexes with BeH2 do not behave as P, As, or Sb Brønsted acids, but unexpectedly as Be acids.
Mallik, Abul K; Qiu, Hongdeng; Oishi, Tomohiro; Kuwahara, Yutaka; Takafuji, Makoto; Ihara, Hirotaka
2015-07-07
For the first time, we synthesized multiple embedded polar groups (EPGs) containing linear C18 organic phases. The new materials were characterized by elemental analysis, IR spectroscopy, (1)H NMR, diffuse reflectance infrared Fourier transform (DRIFT), solid-state (13)C cross-polarization magic angle spinning (CP/MAS) NMR, suspended-state (1)H NMR, and differential scanning calorimetry (DSC). (29)Si CP/MAS NMR was carried out to investigate the degree of cross-linking of the silane and silane functionality of the modified silica. Solid-state (13)C CP/MAS NMR and suspended-state (1)H NMR spectroscopy indicated a higher alkyl chain order for the phase containing four EPGs than for the phase with three EPGs. To correlate the NMR results with temperature-dependent chromatographic studies, standard reference materials (SRM 869b and SRM 1647e), a column selectivity test mixture for liquid chromatography was employed. A single EPG containing the C18 phase was also prepared in a similar manner to be used as a reference column especially for the separation of basic and polar compounds in reversed-phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC), respectively. Detailed chromatographic characterization of the new phases was performed in terms of their surface coverage, hydrophobic selectivity, shape selectivity, hydrogen bonding capacity, and ion-exchange capacity at pH 2.7 and 7.6 for RPLC as well as their hydrophilicity, the selectivity for hydrophilic-hydrophobic substituents, the selectivity for the region and configurational differences in hydrophilic substituents, the evaluation of electrostatic interactions, and the evaluation of the acidic-basic nature for HILIC-mode separation. Furthermore, peak shapes for the basic analytes propranolol and amitriptyline were studied as a function of the number of EPGs on the C18 phases in the RPLC. The chromatographic performance of multiple EPGs containing C18 HILIC phases is illustrated by the separation of sulfa drugs, β-blockers, xanthines, nucleic acid bases, nucleosides, and water-soluble vitamins. Both of the phases showed the best performance for the separation of shape-constrained isomers, nonpolar, polar, and basic compounds in RPLC- and HILIC-mode separation of sulfa drugs, and other polar and basic analytes compared to the conventional alkyl phases with and without embedded polar groups and HILIC phases. Surprisingly, one phase would be able to serve the performance of three different types of phases with very high selectivity, and we named this phase the "smart phase". Versatile applications with a single column will reduce the column purchasing cost for the analyst as well as achieve high separation, which is challenging with the commercially available columns.
Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P
2015-06-01
A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zhou, Shujun; Cao, Jiliang; Qiu, Feng; Kong, Weijun; Yang, Shihai; Yang, Meihua
2013-01-01
Glycyrrhizae species are popular ingredients of herbal medicine in most traditional Chinese medicine prescriptions, and they mainly contain flavonoids and triterpene saponins. The contents of these bioactive compounds may vary in different batches and affect the therapeutic effects. Thus comprehensive quality control and monitoring of their herbal formulation are of paramount concern. To establish a rapid, effective pressurised liquid extraction (PLE) and ultra-performance liquid chromatography coupled with photodiode array (UPLC-PDA) method to evaluate the quality of Glycyrrhizae species. Radix Glycyrrhizae was extracted by PLE using 70% ethanol at 100°C for 15 min during three static extraction cycles. Separation was performed using an UPLC system to quantify five bioactive compounds, namely liquiritin apioside, liquiritin, liquiritigenin, glycyrrhizic acid and glycyrrhetinic acid, in 12 batches of samples of different origins in China. Furthermore, the samples were analysed using an ultra-performance liquid chromatography coupled with electrospray ionisation and time-of-flight mass spectrometry (UPLC/ESI-QTOF-MS) system to confirm the results. The calibration curves of all five analytes showed good linearity (R(2) > 0.9997). Accuracy, precision and repeatability were all within required limits. The mean recoveries measured at the three concentrations were higher than 93.7% with RSDs lower than < 3.33% for the targets. The established PLE and UPLC-PDA method could serve as a rapid and effective method for quality evaluation of Radix Glycyrrhizae. The UPLC technique can be considered as an attractive alternative to HPLC in routine quality control of Chinese medicine, especially in situations where high sample throughput and fast analytical speed are required. Copyright © 2013 John Wiley & Sons, Ltd.
High throughput screening of active pharmaceutical ingredients by UPLC.
Al-Sayah, Mohammad A; Rizos, Panagiota; Antonucci, Vincent; Wu, Naijun
2008-07-01
Ultra performance LC (UPLC) was evaluated as an efficient screening approach to facilitate method development for drug candidates. Three stationary phases were screened: C-18, phenyl, and Shield RP 18 with column dimensions of 150 mm x 2.1 mm, 1.7 microm, which should theoretically generate 35,000 plates or 175% of the typical column plate count of a conventional 250 mm x 4.6 mm, 5 microm particle column. Thirteen different active pharmaceutical ingredients (APIs) were screened using this column set with a standardized mobile-phase gradient. The UPLC method selectivity results were compared to those obtained for these compounds via methods developed through laborious trial and error screening experiments using numerous conventional HPLC mobile and stationary phases. Peak capacity was compared for columns packed with 5 microm particles and columns packed with 1.7 microm particles. The impurities screened by UPLC were confirmed by LC/MS. The results demonstrate that simple, high efficiency UPLC gradients are a feasible and productive alternative to more conventional multiparametric chromatographic screening approaches for many compounds in the early stages of drug development.
Gunn, Josh; Kriger, Scott; Terrell, Andrea R
2010-01-01
The simultaneous determination and quantification of cocaine and its major metabolite, benzoylecgonine, in meconium using UPLC-MS/MS is described. Ultra-performance liquid chromatography (UPLC) is an emerging analytical technique which draws upon the principles of chromatography to run separations at higher flow rates for increased speed, while simultaneously achieving superior resolution and sensitivity. Extraction of cocaine and benzoylecgonine from the homogenized meconium matrix was achieved with a preliminary protein precipitation or protein 'crash' employing cold acetonitrile, followed by a mixed mode solid phase extraction (SPE). Following elution from the SPE cartridge, eluents were dried down under nitrogen, reconstituted in 200 microL of DI water:acetonitrile (ACN) (75:25), and injected onto the UPLC/MS/MS for analysis. The increased speed and separation efficiency afforded by UPLC, allowed for the separation and subsequent quantification of both analytes in less than 2 min. Analytes were quantified using multiple reaction monitoring (MRM) and six-point calibration curves constructed in negative blood. Limits of detection for both analytes were 3 ng/g and the lower limit of quantitation (LLOQ) was 30 ng/g.
Farag, Mohamed A; Gad, Haidy A; Heiss, Andreas G; Wessjohann, Ludger A
2014-05-15
Nigella sativa, commonly known as black cumin seed, is a popular herbal supplement that contains numerous phytochemicals including terpenoids, saponins, flavonoids, alkaloids. Only a few of the ca. 15 species in the genus Nigella have been characterized in terms of phytochemical or pharmacological properties. Here, large scale metabolic profiling including UPLC-PDA-MS and GC-MS with further multivariate analysis was utilized to classify 6 Nigella species. Under optimized conditions, we were able to annotate 52 metabolites including 8 saponins, 10 flavonoids, 6 phenolics, 10 alkaloids, and 18 fatty acids. Major peaks in UPLC-MS spectra contributing to the discrimination among species were assigned as kaempferol glycosidic conjugates, with kaempferol-3-O-[glucopyranosyl-(1→2)-galactopyranosyl-(1→2)-glucopyranoside, identified as potential taxonomic marker for N. sativa. Compared with GC-MS, UPLC-MS was found much more efficient in Nigella sample classification based on genetic and geographical origin. Nevertheless, both GC-MS and UPLC-MS support the remote position of Nigella nigellastrum in relation to the other taxa. Copyright © 2013 Elsevier Ltd. All rights reserved.
Zhuang, Bo; Bi, Zhi-Ming; Wang, Zi-Yuan; Duan, Li; Lai, Chang-Jiang-Sheng; Liu, E-Hu
2018-05-30
Platycladi Cacumen (PC) is a traditional Chinese medicine used for the treatment of hemorrhages, cough, asthma and hair loss. To get a better understanding of the chemical constituents in PC, ultra-high performance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry (UPLC-Q-TOF-MS/MS) and diagnostic ion filtering strategy were firstly employed for chemical profiling of PC. A total of 43 compounds including organic acids and derivatives, flavonoids as well as phenylpropanolds were unambiguously or reasonably identified. Coumarin and lignan were reported for the first time in PC. Chemical variation of 39 batches of PC from different geographical origins and 10 batches of processed product of PC was subsequently investigated by quantitation of nine major flavonoids. The results determined by UPLC coupled with diode array detection (UPLC-DAD) and hierarchical cluster analysis (HCA) indicated that the contents of flavonoids in PC samples differ greatly. This work provides an efficient approach to comprehensively evaluate the quality of PC. Copyright © 2018 Elsevier B.V. All rights reserved.
Mei, Shenghui; Zhu, Leting; Li, Xingang; Wang, Jiaqing; Jiang, Xueyun; Chen, Haiyan; Huo, Jiping; Yang, Li; Lin, Song; Zhao, Zhigang
2017-01-01
Methotrexate (MTX) plasma concentration is routinely monitored to guide the dosage regimen of rescue drugs. This study aims to develop and validate an ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for plasma MTX analysis, and to establish its agreement with the fluorescence polarization immunoassay (FPIA) in patients with high-dose MTX therapy. Separation was achieved by gradient elution with methanol and water (0.05% formic acid) at 40°C with a run time of 3 min. The intra- and inter-day inaccuracy and imprecision of the UPLC-MS/MS method were -4.25 to 3.1 and less than 7.63%, respectively. The IS-normalized recovery and matrix effect were 87.05 to 92.81 and 124.43 to 134.57%. The correlation coefficients between UPLC-MS/MS and FPIA were greater than 0.98. The UPLC-MS/MS method was in agreement with the FPIA at high levels of MTX (1.0 - 100 μmol/L), but not at low levels (0.01 - 1.0 μmol/L). Further studies are warranted to confirm these results.
Zhang, Rong; Watson, David G; Wang, Lijie; Westrop, Gareth D; Coombs, Graham H; Zhang, Tong
2014-10-03
It has been reported that HILIC column chemistry has a great effect on the number of detected metabolites in LC-HRMS-based untargeted metabolite profiling studies. However, no systematic investigation has been carried out with regard to the optimisation of mobile phase characteristics. In this study using 223 metabolite standards, we explored the retention mechanisms on three zwitterionic columns with varied mobile phase composition, demonstrated the interference from poor chromatographic peak shapes on the output of data extraction, and assessed the quality of chromatographic signals and the separation of isomers under each LC condition. As expected, on the ZIC-cHILIC column the acidic metabolites showed improved chromatographic performance at low pH which can be attributed to the opposite arrangement of the permanently charged groups on this column in comparison with the ZIC-HILIC column. Using extracts from the protozoan parasite Leishmania, we compared the numbers of repeatedly detected LC-HRMS features under different LC conditions with putative identification of metabolites not amongst the standards being based on accurate mass (±3ppm). Besides column chemistry, the pH of the mobile phase plays a key role in not only determining the retention mechanisms of solutes but also the output of the LC-HRMS data processing. Fast evaporation of ammonium carbonate produced less ion suppression in ESI source and consequently improved the detectability of the metabolites in low abundance in comparison with other ammonium salts. Our results show that the combination of a ZIC-pHILIC column with an ammonium carbonate mobile phase, pH 9.2, at 20mM in the aqueous phase or 10mM in both aqueous and organic mobile phase components, provided the most suitable LC conditions for LC-HRMS-based untargeted metabolite profiling of Leishmania parasite extracts. The signal reliability of the mass spectrometer used in this study (Exactive Orbitrap) was also investigated. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Nu; Boswell, Paul G
2017-10-20
Gradient retention times are difficult to project from the underlying retention factor (k) vs. solvent composition (φ) relationships. A major reason for this difficulty is that gradients produced by HPLC pumps are imperfect - gradient delay, gradient dispersion, and solvent mis-proportioning are all difficult to account for in calculations. However, we recently showed that a gradient "back-calculation" methodology can measure these imperfections and take them into account. In RPLC, when the back-calculation methodology was used, error in projected gradient retention times is as low as could be expected based on repeatability in the k vs. φ relationships. HILIC, however, presents a new challenge: the selectivity of HILIC columns drift strongly over time. Retention is repeatable in short time, but selectivity frequently drifts over the course of weeks. In this study, we set out to understand if the issue of selectivity drift can be avoid by doing our experiments quickly, and if there any other factors that make it difficult to predict gradient retention times from isocratic k vs. φ relationships when gradient imperfections are taken into account with the back-calculation methodology. While in past reports, the accuracy of retention projections was >5%, the back-calculation methodology brought our error down to ∼1%. This result was 6-43 times more accurate than projections made using ideal gradients and 3-5 times more accurate than the same retention projections made using offset gradients (i.e., gradients that only took gradient delay into account). Still, the error remained higher in our HILIC projections than in RPLC. Based on the shape of the back-calculated gradients, we suspect the higher error is a result of prominent gradient distortion caused by strong, preferential water uptake from the mobile phase into the stationary phase during the gradient - a factor our model did not properly take into account. It appears that, at least with the stationary phase we used, column distortion is an important factor to take into account in retention projection in HILIC that is not usually important in RPLC. Copyright © 2017 Elsevier B.V. All rights reserved.
Min, Jun Zhe; Shimizu, Yoshiha; Toyo'oka, Toshimasa; Inagaki, Shinsuke; Kikura-Hanajiri, Ruri; Goda, Yukihiro
2008-10-01
To avoid the spreading of illegal drugs, a designated drug regulation system was introduced along with revision of the Pharmaceutical Affairs Law in Japan in 2006, and 32 substances including phenethylamine-type drugs were listed in April 2007. In this study, a new simultaneous determination method, based on ultra-fast liquid chromatography coupled with fluorescence detection (UFLC-FL), was developed for the 11 designated phenethylamine drugs. The phenethylamines were labeled with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) at 60 degrees C for 2h in 0.1M borax (pH 9.3). The resulting 11 fluorophores were completely separated by reversed-phase chromatography using an ACQUITY UPLC BEH C(18) column (2.1 mm x 100 mm 1.7 microm) and fluorometrically detected at 550 nm (excitation at 450 nm). The calibration curves obtained from the peak areas versus the injection amounts of the phenethylamines showed a good linearity. The limits of detection (signal-to-noise ratio of 3: S/N=3) on the chromatogram were in the range from 10 fmol (PMMA) to 2.5pmol (MMDA-2). Good accuracy (%) and precision (CV) by intra-day assay and inter-day assay were also obtained using the present procedure. The method was applied to the qualitative and quantitative analyses of phenethylamine in real products obtained from the Japanese market. As the results, BDB (0.24 mg/mg), MMDA-2 (0.98 mg/mL) and 2C-I (0.016 mg/mg) were identified from the different products (powder, liquid and mushroom like). Because the procedure is simple, selective and sensitive, the present method seems to be useful for the qualitative and quantitative analyses of the designated phenethylamines in various samples including biological specimens.
Xu, Beibei; Yang, Guanyi; Ge, Shufan; Yin, Taijun; Hu, Ming; Gao, Song
2013-11-01
The purpose of this study is to develop an UPLC-MS/MS method to quantify 3-hydroxyflavone (3-HF) and its metabolite, 3-hydroxyflavone-glucuronide (3-HFG) from biological samples. A Waters BEH C8 column was used with acetonitrile/0.1% formic acid in water as mobile phases. The mass analysis was performed in an API 5500 Qtrap mass spectrometer via multiple reaction monitoring (MRM) with positive scan mood. The one-step protein precipitation by acetonitrile was used to extract the analytes from blood. The results showed that the linear response range was 0.61-2500.00 nM for 3-HF and 0.31-2500.00 nM for 3-HFG. The intra-day variance is less than 16.5% and accuracy is in 77.7-90.6% for 3-HF and variance less than 15.9%, accuracy in 85.1-114.7% for 3-HFG. The inter-day variance is less than 20.2%, accuracy is in 110.6-114.2% for 3-HF and variance less than 15.6%, accuracy in 83.0-89.4% for 3-HFG. The analysis was done within 4.0 min. Only 10 μl of blood is needed due to the high sensitivity of this method. The validated method was successfully used to pharmacokinetic study in A/J mouse, transport study in the Caco-2 cell culture model, and glucuronidation study using mice liver and intestine microsomes. The applications revealed that this method can be used for 3-HF and 3-HFG analysis in blood as well as in bioequivalent buffers such HBSS and KPI. Copyright © 2013 Elsevier B.V. All rights reserved.
Hou, Xiao-Lin; Chen, Guo; Zhu, Li; Yang, Ting; Zhao, Jian; Wang, Lei; Wu, Yin-Liang
2014-07-01
A simple, sensitive and reliable analytical method was developed for the simultaneous determination of 38 veterinary drugs (18 sulfonamides, 11 quinolones and 9 benzimidazoles) and 8 metabolites of benzimidazoles in bovine milk by ultra high performance liquid chromatography-positive electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS). Samples were extracted with acidified acetonitrile, cleaned up with Oasis(®) MCX cartridges, and analyzed by LC-MS/MS on an Acquity UPLC(®) BEH C18 column with gradient elution. The method allows such multi-analyte measurements within a 13min runtime while the specificity is ensured through the MRM acquisition mode. The method was validated according to the European Commission Decision 2002/657/EC determining specificity, decision limit (CCα), detection capability (CCβ), recovery, precision, linearity and stability. For compounds which have MRLs in bovine milk, the CCα values fall into a range from 11 to 115μg/kg, and the CCβ values fall within a range of 12-125μg/kg. For compounds which have not MRLs in bovine milk, the CCα values fall into a range from 0.01 to 0.08μg/kg, and the CCβ values fall within a range of 0.02-0.11μg/kg. The mean recoveries of the 46 analytes were between 87 and 119%. The calculated RSD values of repeatability and within-laboratory reproducibility experiments were below 11% and 15% for the 46 compounds, respectively. The method was demonstrated to be suitable for the simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk. Copyright © 2014 Elsevier B.V. All rights reserved.
Xu, Beibei; Yang, Guanyi; Ge, Shufan; Yin, Taijun; Hu, Ming; Gao, Song
2015-01-01
The purpose of this study is to develop an UPLC-MS/MS method to quantify 3-hydroxy-flavone (3-HF) and its metabolite, 3-hydroxyflavone-glucuronide (3-HFG) from biological samples. A Waters BEH C8 column was used with acetonitrile/0.1 % formic acid in water as mobile phases. The mass analysis was performed in an API 5500 Qtrap mass spectrometer via multiple reaction monitoring (MRM) with positive scan mood. The one-step protein precipitation by acetonitrile was used to extract the analytes from plasma. The results showed that the linear response range was 0.61– 2,500.00 nM for 3-HF and 0.31– 2,500.00 nM for 3-HFG. The intra-day variance is less 16.48 % and accuracy is in 77.70–90.64 % for 3-HF and variance less than 15.86%, accuracy in 85.08–114.70 % for 3-HFG. The inter-day variance is less than 20.23 %, accuracy is in 110.58–114.2 % for 3-HF and variance less than 15.59 %, accuracy in 83.00–89.40% for 3-HFG. The analysis was done within 4.0 min. Only 10 μL of blood is needed due to the high sensitivity of this method. The validated method was successfully used to pharmacokinetic study in A/J mouse, transport study in the Caco-2 cell culture model, and glucuronidation study using mice liver and intestine microsomes. The applications revealed that this method can be used for 3-HF and 3-HFG analysis in blood as well as in bioequivalent buffers such HBSS and KPI. PMID:23973631
Chen, Xiaopeng; Walter, Kyla M; Miller, Galen W; Lein, Pamela J; Puschner, Birgit
2018-06-01
Environmental toxicants that interfere with thyroid hormone (TH) signaling can impact growth and development in animals and humans. Zebrafish represent a model to study chemically induced TH disruption, prompting the need for sensitive detection of THs. Simultaneous quantification of 3,3',5-triiodo-l-thyronine (T3), thyroxine (T4), 3,3',5'-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (3,5-T2) and 3,3'-diiodo-l-thyronine (3,3'-T2) in zebrafish larvae was achieved by ultra-performance liquid chromatography-tandem mass spectrometry in positive ion mode. Solid-phase extraction with SampliQ cartridges and derivatization with 3 m hydrochloric acid in n-butanol reduced matrix effects. Derivatized compounds were separated on an Acquity UPLC BEH C 18 column with mobile phases consisting of 0.1% acetic acid in deionized water and 0.1% acetic acid in methanol. The limits of detection ranged from 0.5 to 0.6 pg injected on column. The method was validated by evaluating recovery (77.1-117.2%), accuracy (87.3-123.9%) and precision (0.5-12.4%) using diluted homogenized zebrafish embryos spiked with all target compounds. This method was then applied to zebrafish larvae collected after 114 h of exposure to polychlorinated biphenyls (PCBs), including PCB 28, PCB 66 and PCB 95, or the technical mixture Aroclor 1254. Exposure to PCB 28 and PCB 95 increased the T4:T3 ratio and decreased the T3:rT3 ratio, demonstrating that this method can effectively detect PCB-induced alterations in THs. Copyright © 2018 John Wiley & Sons, Ltd.
Zheng, Zhijie; Yan, Tongmeng; Chen, Weiying; Ye, Ling; Tang, Lan; Liu, Zhongqiu
2012-08-01
A rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry method was developed and validated for the determination and quantification of ephedrine in rat plasma samples. An Acquity UPLC BEH C18 column (1.7 μm, 2.1 mm × 50 mm) was used for chromatographic separation. Electrospray ionization in the positive mode was used, and the precursor-fragment ion pairs of m/z 166/148 and m/z 289/97 were adopted to characterize ephedrine and testosterone (internal standard), respectively. The method was validated using 10, 100 and 500 ng/mL of ephedrine. It demonstrated adequate levels of precision and accuracy, matrix effect, extraction recovery and stability. Linearity over the concentration range of 0.5-2000 ng/mL was acceptable with a correlation coefficient (r²) better than 0.990. To determine the pharmacokinetic behaviour of this sympathomimetic compound in the Sprague-Dawley rats, ephedrine hydrochloride, Herba Ephedrae single-herb and Wu Tou Tang decoctions were administered orally, and ephedrine hydrochloride was also administered by intravenous injection, and blood samples were collected over 24 h. Ephedrine was measured in plasma and pharmacokinetic parameters were determined by using the standard non-compartmental method and calculated by using Practical Pharmacokinetic Program-Version 87/97. The AUC(0-t) and T(max) values were significantly different (p < 0.05). Ephedrine AUC(0-t) values were significantly lower following the Wu Tou Tang decoction compared to the other oral treatments, suggesting that some components in the decoction may reduce the bioavailability of ephedrine.
Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Sunil P
2012-10-01
The objective of the current investigation was to study the degradation behavior of irinotecan hydrochloride under different International Conference on Harmonization (ICH) recommended stress conditions using ultra-performance liquid chromatography and liquid chromatography-mass spectrometry and to establish a validated stability-indicating reverse-phase ultra-performance liquid chromatographic method for the quantitative determination of irinotecan hydrochloride and its seven impurities and degradation products in pharmaceutical dosage forms. Irinotecan hydrochloride was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Irinotecan hydrochloride was found to degrade significantly in oxidative and base hydrolysis and photolytic degradation conditions. The degradation products were well resolved from the main peak and its impurities, thus proving the stability-indicating power of the method. Chromatographic separation was achieved on a Waters Acquity BEH C8 (100 × 2.1 mm) 1.7-µm column with a mobile phase containing a gradient mixture of solvent A (0.02M KH(2)PO(4) buffer, pH 3.4) and solvent B (a mixture of acetonitrile and methanol in the ratio of 62:38 v/v). The mobile phase was delivered at a flow rate of 0.3 mL/min with ultraviolet detection at 220 nm. The run time was 8 min, within which irinotecan and its seven impurities and degradation products were satisfactorily separated. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of irinotecan hydrochloride in pharmaceutical dosage forms.
Emory, Joshua F.; Seserko, Lauren A.; Marzinke, Mark A.
2014-01-01
Background Maraviroc is a CCR5 antagonist that has been utilized as a viral entry inhibitor in the management of HIV-1. Current clinical trials are pursuing maraviroc drug efficacy in both oral and topical formulations. Therefore, in order to fully understand drug pharmacokinetics, a sensitive method is required to quantify plasma drug concentrations. Methods Maraviroc-spiked plasma was combined with acetonitrile containing an isotopically-labeled internal standard, and following protein precipitation, samples were evaporated to dryness and reconstituted for liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. Chromatographic separation was achieved on a Waters BEH C8, 50 × 2.1 mm UPLC column, with a 1.7 μm particle size and the eluent was analyzed using an API 4000 mass analyzer in selected reaction monitoring mode. The method was validated as per FDA Bioanalytical Method Validation guidelines. Results The analytical measuring range of the LC-MS/MS method is 0.5-1000 ng/ml. Calibration curves were generated using weighted 1/x2 quadratic regression. Inter-and intra-assay precision was ≤ 5.38% and ≤ 5.98%, respectively; inter-and intra-assay accuracy (%DEV) was ≤ 10.2% and ≤ 8.44%, respectively. Additional studies illustrated similar matrix effects between maraviroc and its internal standard, and that maraviroc is stable under a variety of conditions. Method comparison studies with a reference LC-MS/MS method show a slope of 0.948 with a Spearman coefficient of 0.98. Conclusions Based on the validation metrics, we have generated a sensitive and automated LC-MS/MS method for maraviroc quantification in human plasma. PMID:24561264
Lien, Guang-Wen; Wen, Ting-Wen; Hsieh, Wu-Shiun; Wu, Kuen-Yuh; Chen, Chia-Yang; Chen, Pau-Chung
2011-03-15
Perfluorinated compounds (PFCs) can cross the placental barrier and enter fetal circulation. This study aimed at developing a fast and sensitive ultra-high performance liquid chromatography/tandem mass spectrometry method for the determination of twelve perfluorinated compounds in cord blood. Samples were processed with protein precipitation using formic acid and methanol, mixed with stable isotope labeled standard, followed by sonication and centrifugation, and were analyzed using a Waters ACQUITY UPLC coupled with a Waters Quattro Premier XE triple-quadrupole mass spectrometer. The instrument was operated in selected reaction monitoring (SRM) with negative electrospray ionization. Using BEH C(18) column (2.1 mm×50 mm, 1.7 μm) with 10-mM N-methylmorpholine/methanol gradient elution provided a fast chromatographic separation (5.5 min) and sharp peaks. Intra- and inter-day calibration bias was less than 7% and intra- and inter-day calibration of relative standard deviations were within 0.02-8.22% for all the analytes and concentrations. The recoveries of PFCs spiked into bovine serum ranged from 85 to 104% with relative standard deviations from 0.02 to 6.37%. The limits of quantitation (LOQs), defined as a signal-to-noise ratio of ten, ranged from 0.15 to 3.1 ng/mL for the twelve PFCs. Perfluorooctanoic acid (PFOA), perfluorooctyl sulfonate (PFOS), perfluoroundecanoic acid (PFUA) and perfluorononanoic acid (PFNA) were detected in up to 68% of umbilical cord plasma (n=444) in Taiwan Birth Panel Study and the health effect of these chemicals on children developmental deserves further investigation. Copyright © 2011 Elsevier B.V. All rights reserved.
Luque-Muñoz, A; Vílchez, J L; Zafra-Gómez, A
2017-07-21
An analytical method for the analysis of 16 pharmaceuticals and personal care products in compost from sewage sludge is successfully validated. Ultrasound assisted extraction with a mixture of acetonitrile:ethyl acetate (1:1, v/v) containing 10% (v/v) of acetic acid was carried out. Two cycles of extraction of 10min were applied. A clean-up of the extracts using salt-assisted liquid-liquid extraction (SALLE) was also included. Experimental design was used for the optimization of the main parameters involved in the extraction and cleaned-up steps. The chromatographic separation was carried out by ultrahigh performance liquid chromatography using a mobile phase gradient mixture of a 13mM buffer ammonium formate solution (pH 9.25) (solvent A) and methanol (solvent B). An ACQUITY UPLC ® BEH C18 column (1.7μm; 2.1×50mm) column was used. Analytes were separated in less than 11min. The compounds were detected and quantified using single reaction monitoring electrospray tandem mass spectrometry. The limits of detection calculated ranged from 0.5 to 4ngg -1 d.w., and the limits of quantification from 2 to 13ngg -1 d.w. Recoveries from 93% to 111%, with relative standar deviations lower than 11% in all cases, were obtained. The method was applied to natural compost samples. High concentrations of some analytes were found. Ketoprofen (510ngg -1 d.w.), methylparaben (240ngg -1 d.w.), diclofenac (175ngg -1 d.w.) and flufenamic acid (128ngg -1 d.w.) were the most abundant. Copyright © 2017 Elsevier B.V. All rights reserved.
Dong, Hao; Zeng, Xiaofang; Bai, Weidong
2018-08-30
The present study reports an ultra high-performance liquid chromatography tandem mass spectrometry method for the simultaneous determination of six bisphenols (bisphenol A, bisphenol B and bisphenol F) and alkylphenols (4-nonylphenol, 4-n-nonylphenol and octylphenol) in hotpot seasoning. Samples were dispersed in n-hexane after addition of internal standards bisphenol A-d 4 and 4-n-nonylphenol-d 4 . Sample solutions were then centrifuged, and the supernatants purified using solid phase extraction with high polarity Carb/PSA composite fillers. Six target analytes were separated on a Waters ACQUITY BEH C18 column by gradient elution with methanol and 0.05% ammonium hydroxide in water as the mobile phase, and determined under multiple reactions monitoring mode. The limits of detection and quantitation, matrix effect, recovery and precision of the method were investigated. Results were linear in the concentration range 0.1-250 µg/L for all compounds of interest, with R 2 > 0.9950. Limits of detection were in the range 0.1-0.4 μg/kg, and limits of quantitation were between 0.5 μg/kg and 1.0 μg/kg. The mean recoveries for negative samples at three spiked concentrations were in the range 87.9%-102.4%, and the intra-day precision and inter-day precision were in the ranges 2.1-8.2% and 4.8-11.2%, respectively. This method is accurate and sensitive, and had good clean-up characteristics, which might apply to screening and quantitation of target bisphenols and alkylphenols in hotpot seasoning. Copyright © 2018 Elsevier Ltd. All rights reserved.
Leng, Ping; Yang, Zhao; Ma, Baohua; Li, Jing; Sun, Jialin; Xie, Yiming; Sun, Yong
2018-03-05
A compound (WJD-A-1) was previously reported as a candidate prodrug of Am80 (tamibarotene), which was approved in Japan in 2005 as a therapeutic agent for recurrent refractory acute promyelocytic leukaemia. A rapid, selective and sensitive ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the first time to simultaneously determine WJD-A-1 and its major phase-I metabolites AM80 in rat plasma. After a simple sample preparation procedure by protein precipitation with methanol and acetonitrile, WJD-A-1, AM80 and the internal standard were chromatographed on an ACQUITY UPLC TM BEH C 18 column. The mobile phase consisted of methanol-0.1% formic acid (80:20, v/v) and the flow rate was 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. Each plasma sample was chromatographed within 2.6 min. The linear calibration curves for WJD-A-1 and the AM80 were obtained in the concentration range of 5.40-5.40 × 10 3 and 5.08-5.08 × 10 3 ng/mL, respectively (r ≥ 0.99). The intra- and inter-day precision (relative standard deviation, RSD) values were less than 8% and the accuracy (relative error, RE) was within ±6.8%, determined from quality control (QC) samples for the analytes. The method herein described was fully validated and successfully applied to pharmacokinetic study of WJD-A-1 following an intravenous administration of 300 μg/kg WJD-A-1 to rats.
Karinen, Ritva; Vindenes, Vigdis; Hasvold, Inger; Olsen, Kirsten Midtbøen; Christophersen, Asbjørg S; Øiestad, Elisabeth
2015-07-01
Quantitative determination of anti-epileptic drug concentrations is of great importance in forensic toxicology cases. Although the drugs are not usually abused, they are important post-mortem cases where the question of both lack of compliance and accidental or deliberate poisoning might be raised. In addition these drugs can be relevant for driving under the influence cases. A reversed phase ultra-performance liquid chromatography-tandem mass spectrometry method has been developed for the quantitative analysis of the anti-epileptic compounds carbamazepine, carbamazepine-10,11-epoxide, gabapentin, lamotrigine, levetiracetam, oxcarbazepine, 10-OH-carbazepine, phenobarbital, phenytoin, pregabalin, and topiramate in whole blood, using 0.1 mL sample volume with methaqualone as internal standard. Sample preparation was a simple protein precipitation with acetonitrile and methanol. The diluted supernatant was directly injected into the chromatographic system. Separation was performed on an Acquity UPLC® BEH Phenyl column with gradient elution and a mildly alkaline mobile phase. The mass spectrometric detection was performed in positive ion mode, except for phenobarbital, and multiple reaction monitoring was used for drug quantification. The limits of quantification for the different anti-epileptic drugs varied from 0.064 to 1.26 mg/L in blood, within-day and day-to-day relative standard deviations from 2.2 to 14.7% except for phenobarbital. Between-day variation for phenobarbital was 20.4% at the concentration level of 3.5 mg/L. The biases for all compounds were within ±17.5%. The recoveries ranged between 85 and 120%. The corrected matrix effects were 88-106% and 84-110% in ante-mortem and post-mortem whole blood samples, respectively. Copyright © 2014 John Wiley & Sons, Ltd.
Zhang, Yan; Liu, Peng; Li, Ning; Wu, Di; Feng, Yun; Song, Yuanyuan; Shi, Yuankai; Han, Xiaohong
2016-07-01
To support a novel anthracycline agent - Sabarubicin's pharmacokinetics study in Chinese small cell lung cancer patients, a rapid, sensitive, and high throughput ultra-performance liquid chromatography tandem mass spectrometry method using Doxorubicin hydrochloride as internal standard (IS) was developed and validated for simultaneously quantifying Sabarubicin and its alcohol metabolite M3 in human plasma. Plasma samples were pre-extracted with n-hexane to remove hydrophobic interferences and the target compounds were extracted into a 1ml mixture of chloroform and isopropanol (1:1, v/v) and separated on an ACQUITY UPLC BEH Shield RP18 (100mm×2.1mm, 1.7μm) column with gradient mobile phase composed of acetonitrile and water containing 0.1% formic acid. Detection was performed by electrospray ionization in the positive ionization mode under multiple reaction monitoring of the transitions at m/z 644→130 for Sabarubicin, m/z 646→333.2 for M3, and m/z 544→360 for IS. For Sabarubicin and M3, calibration curves over 2-400ng/ml and 0.5-100ng/ml could achieve excellent linearity respectively(r>0.99). Intra- and inter-day precisions were 1.5%-9.1% and 2.2%-12.8%, and accuracy were -9.6% to 0.7% and -4.8% to 5.9% for Sabarubicin and M3 respectively at four concentration levels. The mean recovery for Sabarubicin was 62.4%, 71.9% for M3, and 58.8% for IS. This method was completely validated and successfully applied in the pharmacokinetics study of Sabarubicin and M3 in Chinese small cell lung cancer patients. Copyright © 2016 Elsevier B.V. All rights reserved.
Ansermot, Nicolas; Brawand-Amey, Marlyse; Kottelat, Astrid; Eap, Chin B
2013-05-31
A sensitive and selective ultra-high performance liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was developed for the fast quantification of ten psychotropic drugs and metabolites in human plasma for the needs of our laboratory (amisulpride, asenapine, desmethyl-mirtazapine, iloperidone, mirtazapine, norquetiapine, olanzapine, paliperidone, quetiapine and risperidone). Stable isotope-labeled internal standards were used for all analytes, to compensate for the global method variability, including extraction and ionization variations. Sample preparation was performed by generic protein precipitation with acetonitrile. Chromatographic separation was achieved in less than 3.0min on an Acquity UPLC BEH Shield RP18 column (2.1mm×50mm; 1.7μm), using a gradient elution of 10mM ammonium formate buffer pH 3.0 and acetonitrile at a flow rate of 0.4ml/min. The compounds were quantified on a tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring. The method was fully validated according to the latest recommendations of international guidelines. Eight point calibration curves were used to cover a large concentration range 0.5-200ng/ml for asenapine, desmethyl-mirtazapine, iloperidone, mirtazapine, olanzapine, paliperidone and risperidone, and 1-1500ng/ml for amisulpride, norquetiapine and quetiapine. Good quantitative performances were achieved in terms of trueness (93.1-111.2%), repeatability (1.3-8.6%) and intermediate precision (1.8-11.5%). Internal standard-normalized matrix effects ranged between 95 and 105%, with a variability never exceeding 6%. The accuracy profiles (total error) were included in the acceptance limits of ±30% for biological samples. This method is therefore suitable for both therapeutic drug monitoring and pharmacokinetic studies. Copyright © 2013 Elsevier B.V. All rights reserved.
Witt, Lukas; Suzuki, Yosuke; Hohmann, Nicolas; Mikus, Gerd; Haefeli, Walter E; Burhenne, Jürgen
2016-08-01
Chlorzoxazone is a probe drug to assess cytochrome P450 (CYP) 2E1 activity (phenotyping). If the pharmacokinetics of the probe drug is linear, pharmacologically ineffective doses are sufficient for the purpose of phenotyping and adverse effects can thus be avoided. For this reason, we developed and validated an assay for the ultrasensitive quantification of chlorzoxazone and 6-hydroxychlorzoxazone in human plasma. Plasma (0.5mL) and liquid/liquid partitioning were used for sample preparation. Extraction recoveries ranged between 76 and 93% for both analytes. Extracts were separated within 3min on a Waters BEH C18 Shield 1.7μm UPLC column with a fast gradient consisting of aqueous formic acid and acetonitrile. Quantification was achieved using internal standards labeled with deuterium or (13)C and tandem mass spectrometry in the multiple reaction monitoring mode using negative electrospray ionization, which yielded lower limits of quantification of 2.5pgmL(-1), while maintaining a precision always below 15%. The calibrated concentration ranges were linear for both analytes (2.5-1000pgmL(-1)) with correlation coefficients of >0.99. Within-batch and batch-to-batch precision in the calibrated ranges for both analytes were <15% and <11% and plasma matrix effects always were below 50%. The assay was successfully applied to assess the pharmacokinetics of chlorzoxazone in two human volunteers after administration of single oral doses (2.5-5000μg). This ultrasensitive assay allowed the determination of chlorzoxazone pharmacokinetics for 8h after microdosing of 25μg chlorzoxazone. Copyright © 2016 Elsevier B.V. All rights reserved.
Viidanoja, Jyrki
2017-01-13
A new liquid chromatography-electrospray ionization-tandem Mass Spectrometry (LC-ESI-MS/MS) method was developed for the determination of more than 20 C 1 -C 6 alkyl and alkanolamines in aqueous matrices. The method employs Hydrophilic Interaction Liquid Chromatography Multiple Reaction Monitoring (HILIC-MRM) with a ZIC-pHILIC column and four stable isotope labeled amines as internal standards for signal normalization and quantification of the amines. The method was validated using a refinery process water sample that was obtained from a cooling cycle of crude oil distillation. The averaged within run precision, between run precision and accuracy were generally within 2-10%, 1-9% and 80-120%, respectively, depending on the analyte and concentration level. Selected aqueous process samples were analyzed with the method. Copyright © 2016 Elsevier B.V. All rights reserved.
Apremilast for Behçet's syndrome--a phase 2, placebo-controlled study.
Hatemi, Gulen; Melikoglu, Melike; Tunc, Recep; Korkmaz, Cengiz; Turgut Ozturk, Banu; Mat, Cem; Merkel, Peter A; Calamia, Kenneth T; Liu, Ziqi; Pineda, Lilia; Stevens, Randall M; Yazici, Hasan; Yazici, Yusuf
2015-04-16
Oral ulcers, the hallmark of Behçet's syndrome, can be resistant to conventional treatment; therefore, alternative agents are needed. Apremilast is an oral phosphodiesterase-4 inhibitor that modulates several inflammatory pathways. We conducted a phase 2, multicenter, placebo-controlled study in which 111 patients with Behçet's syndrome who had two or more oral ulcers were randomly assigned to receive 30 mg of apremilast twice daily or placebo for 12 weeks. This regimen was followed by a 12-week extension phase in which the placebo group was switched to apremilast and a 28-day post-treatment observational follow-up phase. The patients and clinicians were unaware of the study assignments throughout the trial. The primary end point was the number of oral ulcers at week 12. Secondary outcomes included pain from these ulcers (measured on a 100-mm visual-analogue scale, with higher scores indicating worse pain), the number of genital ulcers, overall disease activity, and quality of life. The mean (±SD) number of oral ulcers per patient at week 12 was significantly lower in the apremilast group than in the placebo group (0.5±1.0 vs. 2.1±2.6) (P<0.001). The mean decline in pain from oral ulcers from baseline to week 12 was greater with apremilast than with placebo (-44.7±24.3 mm vs. -16.0±32.5 mm) (P<0.001). Nausea, vomiting, and diarrhea were more common in the apremilast group (with 22, 9, and 12 incidents, respectively, among 55 patients) than in the placebo group (with 10, 1, and 2 incidents, respectively, among 56 patients), findings that were similar to those in previous studies of apremilast. There were two serious adverse events in patients receiving apremilast. Apremilast was effective in treating oral ulcers, which are the cardinal manifestation of Behçet's syndrome. This preliminary study was neither large enough nor long enough to assess long-term efficacy, the effect on other manifestations of Behçet's syndrome, or the risk of uncommon serious adverse events. (Funded by Celgene; ClinicalTrials.gov number, NCT00866359.).
Bodaghi, Bahram; Gendron, Gael; Wechsler, Bertrand; Terrada, Céline; Cassoux, Nathalie; Du Le Thi Huong; Lemaitre, Claire; Fradeau, Christine; LeHoang, Phuc
2007-01-01
Aim Severe uveitis is potentially associated with visual impairment or blindness in young patients. Therapeutic strategies remain controversial. The efficacy of interferon alpha‐2a (IFN‐α2a) in severe uveitis, refractory to steroids and conventional immunosuppressive agents, was evaluated. Patients and methods Patients were included after a major relapse of uveitis following corticosteroids and immunosuppressants. IFN‐α2a (3 million units three times a week) was administered subcutaneously. Efficacy was assessed by improvement in visual acuity, decrease in vitreous haze, resolution of retinal vasculitis and macular oedema, assessed by fundus examination and fluorescein angiography, and decrease in oral prednisone threshold. Results 45 patients were included. Median age was 32.3 years (range 8–58) and sex ratio (F/M) was 0.66. Uveitis was associated with Behçet's disease in 23 cases (51.1%) and with other entities in 22 cases (48.9%). Median duration of uveitis before interferon therapy was 34.9 months (range 3.4–168.7) and an average of 3.26 relapses following corticosteroids and immunosuppressants was noted. Uveitis was controlled in 82.6% of patients with Behçet's disease and 59% of patients with other types of uveitis (p = 0.07). During a mean follow‐up of 29.6 months (range 14–55), median oral prednisone threshold decreased significantly from 23.6 mg/day (range 16–45) to 10 mg/d (range 4–14) (p<0.001). Interferon was discontinued in 10 patients (22.2%) with Behçet's disease and in four patients without Behçet's disease. Relapses occurred in four and one cases, respectively. Conclusions Interferon therapy appears to be an efficient strategy in severe and relapsing forms of Behçet's disease but also in other uveitic entities. However, it seems to act more to suspend rather than cure the disease. Therefore, IFN‐α2a may be proposed as a secondline strategy after failure of conventional immunosuppressants. PMID:17050581
Rehman, Shaheed Ur; Kim, In Sook; Choi, Min Sun; Luo, Zengwei; Yao, Guangming; Xue, Yongbo; Zhang, Yonghui; Yoo, Hye Hyun
2016-02-20
Kinsenoside is a major bioactive constituent isolated from Anoectochilus formosanus and is investigated as an antihyperlipidemic candidate. In this study, a rapid, sensitive, and reliable bioanalytical method was developed for the determination of kinsenoside in rat plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). The plasma sample was pretreated with 1% acetic acid, followed by protein precipitation with acetonitrile:methanol (70:30). Chromatographic separation was performed on a HILIC silica column (2.1mm×100mm, 3μm). The mobile phases consisted of 0.1% acetic acid in distilled water (solvent A) and 0.1% acetic acid in acetonitrile (solvent B). A gradient program was used at a flow rate of 0.2mL/min. For mass spectrometric detection, the multiple reaction monitoring mode was used; the MRM transitions were m/z 265.2→m/z 102.9 for kinsenoside and m/z 163.3→m/z 132.1 for the internal standard (IS) nicotine in the positive ionization mode. A calibration curve was constructed in the range of 2-500ng/mL. The intra- and interday precision and accuracy were within 5%. The HILIC-MS/MS method was specific, accurate, and reproducible and was successfully applied in a pharmacokinetic study of kinsenoside in rats. Copyright © 2015 Elsevier B.V. All rights reserved.
Szczesny, Damian; Bartosińska, Ewa; Jacyna, Julia; Patejko, Małgorzata; Siluk, Danuta; Kaliszan, Roman
2018-02-01
Trigonelline is a pyridine alkaloid found in fenugreek seeds and coffee beans. Most of the previous studies are concerned with the quantification of trigonelline along with other constituents in coffee herbs or beverages. Only a few have focused on its determination in animal or human tissues by applying different modes of HPLC with UV or MS detection. The aim of the study was to develop and validate a fast and simple method for trigonelline determination in serum by the use of hydrophilic interaction liquid chromatography (HILIC) with ESI-MS/MS detection. Separation of trigonelline was achieved on a Kinetex HILIC column operated at 35°C with acetonitrile-ammonium formate (10 mm, pH = 3) buffer mixture (55:45, v/v) as the mobile phase. The developed method was successfully applied to determine trigonelline concentration in mouse serum after intravenous administration of 10 mg/kg. The developed assay is sensitive (limit of detection = 1.5 ng/mL, limit of quantification = 5.0 ng/mL) and linear in a concentration range from 5.0 to 250.0 ng/mL. Sample preparation is limited to deproteinization, centrifugation and filtration. The application of the HILIC mode of chromatography with MS detection and selection of deuterated trigonelline as internal standard allowed a rapid and precise method of trigonelline quantification to be to developed. Copyright © 2017 John Wiley & Sons, Ltd.
Johnson, Caroline H.; Patterson, Andrew D.; Krausz, Kristopher W.; Lanz, Christian; Kang, Dong Wook; Luecke, Hans; Gonzalez, Frank J.; Idle, Jeffrey R.
2011-01-01
Radiation metabolomics has aided in the identification of a number of biomarkers in cells and mice by ultra-performance liquid chromatography-coupled time-of-flight mass spectrometry (UPLC-ESI-QTOFMS) and in rats by gas chromatography-coupled mass spectrometry (GCMS). These markers have been shown to be both dose- and time-dependent. Here UPLC-ESI-QTOFMS was used to analyze rat urine samples taken from 12 rats over 7 days; they were either sham-irradiated or γ-irradiated with 3 Gy after 4 days of metabolic cage acclimatization. Using multivariate data analysis, nine urinary biomarkers of γ radiation in rats were identified, including a novel mammalian metabolite, N-acetyltaurine. These upregulated urinary biomarkers were confirmed through tandem mass spectrometry and comparisons with authentic standards. They include thymidine, 2′-deoxyuridine, 2′deoxyxanthosine, N1-acetylspermidine, N-acetylglucosamine/galactosamine-6-sulfate, N-acetyltaurine, N-hexanoylglycine, taurine and, tentatively, isethionic acid. Of these metabolites, 2′-deoxyuridine and thymidine were previously identified in the rat by GCMS (observed as uridine and thymine) and in the mouse by UPLC-ESI-QTOFMS. 2′Deoxyxanthosine, taurine and N-hexanoylglycine were also seen in the mouse by UPLC-ESI-QTOFMS. These are now unequivocal cross-species biomarkers for ionizing radiation exposure. Downregulated biomarkers were shown to be related to food deprivation and starvation mechanisms. The UPLC-ESI-QTOFMS approach has aided in the advance for finding common biomarkers of ionizing radiation exposure. PMID:21309707
Tian, Jingzhi; Rustum, Abu
2018-02-01
Imidacloprid is used as an active pharmaceutical ingredient (API) in veterinary drugs to control fleas and ticks for dogs and cats. Here we are reporting for the first time a validated stability-indicating reversed-phase UPLC-UV method for the assay of imidacloprid and estimation of its related compounds. The stability-indicating capability of this method has been demonstrated by a forced degradation study. All related compounds including processing impurities, imidacloprid API and degradates from stressed samples were well separated from each other. Structures of major degradates from forced degradation study were elucidated through UPLC-MS/MS and key degradation pathways were proposed from the proposed chemical structures of major degradates. The UPLC-UV method is carried out using an HSS T3 column (C18, 2.1 × 30 mm, 1.8 μm particle size) maintained at 30°C with mobile phase A (0.05% v/v of phosphoric acid in water) and mobile phase B (methanol/acetonitrile 75/25 v/v). Analytes are separated by a gradient elution and detected at 270 nm. The UPLC method is green and fast with only 6.5 min run time and about 3.5 ml mobile phase consumption for each sample analysis. The UPLC-UV method was validated according to ICH guidelines. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Esatoglu, Sinem Nihal; Hatemi, Gulen; Salihoglu, Ayse; Hatemi, Ibrahim; Soysal, Teoman; Celik, Aykut Ferhat
2015-01-01
A number of patients with Behçet's disease (BD) associated with myelodysplastic syndrome (MDS) with or without trisomy 8 have been reported. A high frequency of gastrointestinal (GI) involvement was reported in such patients. The aim of this systematic literature review was to delineate whether GI involvement is an inherent feature of BD associated with MDS, whether these patients do actually have BD rather than GI symptoms related to MDS, and whether the presence of trisomy 8 plays a role in the disease expression of BD associated with MDS. A systematic literature review was performed in PubMed using the keywords (Behçet's disease OR Behçet's syndrome) AND (myelodysplastic syndrome OR trisomy 8) until December 2013. Data from 39 manuscripts that met the inclusion criteria, reporting on 52 patients were analysed. GI involvement was common in reports from both the Far East and non-Far East countries (75% vs. 50.0%, p=0.15). These patients had typical BD manifestations, except for 1 patient who had only oral ulcers and gastrointestinal involvement. The presence of trisomy 8 seems to be associated with an increased frequency of fever (79.5% vs. 33.3%, p=0.005). GI involvement seems to be an inherent feature of BD associated with MDS regardless of geographic differences. Despite the increased frequency of GI involvement in these patients, MDS does not seem to modify the clinical expression of gastrointestinal involvement. Presence of trisomy 8 seems to modify the disease expression with an increased frequency of fever.
McLean, B N; Miller, D; Thompson, E J
1995-01-01
A retrospective study of CSF and serum analysis from a total of 43 patients with sarcoidosis, 20 with systemic lupus erythematosus, and 12 with Behçet's disease with neurological involvement found local synthesis of oligoclonal IgG using isoelectric focusing and immunoblotting in 51%, 25%, and 8% respectively at some stage in their disease. Blood-brain barrier breakdown, when assessed with an albumin ratio found 47% of patients with sarcoidosis, 30% of those with systemic lupus erythematosus, and 42% of patients with Behçet's disease exhibiting abnormal barrier function at some time. Serial CSF analysis showed that clinical relapses were associated with worsening barrier function and in some patients the development of local oligoclonal IgG synthesis; conversely steroid treatment led to a statistically significant improvement in barrier function, and in two patients a loss of oligoclonal IgG bands. A higher proportion of patients had MRI abnormalities than oligoclonal IgG or blood-brain barrier breakdown, MRI being abnormal in 16 of 19 patients with sarcoidosis, three of four patients with systemic lupus erythematosus, and seven of nine patients with Behçet's disease, although this may have been due to temporal factors. In the differential diagnosis of chronic neurological disorders, locally synthesised oligoclonal IgG cannot distinguish between diseases, but the loss of bands seen in two patients contrasts with what is seen in multiple sclerosis, and thus may be a useful diagnostic clue. PMID:7745401
Clinical Experience of Interferon Alfa-2a Treatment for Refractory Uveitis in Behçet's Disease.
Park, Ji-Youn; Chung, Yoo-Ri; Lee, Kihwang; Song, Ji Hun; Lee, Eun-So
2015-07-01
Behçet's disease (BD) involves multisystem vasculitis of unknown origin. Ocular manifestations of BD mostly include bilateral panuveitis and retinal vasculitis, which are very challenging to treat. Interferon alfa-2a (IFN) has been recently introduced for treating refractory Behçet uveitis, mainly in Germany and Turkey. Nonetheless, there is so far no consensus about the ideal treatment regimen of IFN for Behçet uveitis. We report our experience of IFN treatment in five Korean BD patients with refractory uveitis. All patients complained of oral ulcers; one patient had a positive pathergy test and 2 showed the presence of HLA-B51. Immunosuppressive agents used prior to IFN treatment included cyclosporine and methotrexate. The IFN treatment was commenced with a dose of 6-9 MIU/day for 7 days, adjusted according to individual ocular manifestations, tapered down to 3 MIU three times in a week, and then discontinued. All patients showed positive response to IFN treatment; 50% of them showed complete response without additional major ocular inflammation during the follow-up period. Other BD symptoms also improved after IFN treatment in most cases. After treatment, the relapse rate and the required dose of oral corticosteroid were decreased in most cases, showing a significant steroid-sparing effect. However, the visual acuity was not improved in most cases due to irreversible macular sequelae. Despite the small sample size of this study, we suggest that, in Korean patients, IFN is an effective treatment modality for BD uveitis as was observed in German and Turkish patients.
Update on the Medical Management of Gastrointestinal Behçet's Disease
Venerito, Vincenzo; Franceschini, Rossella; Lapadula, Giovanni; Galeazzi, Mauro; Frediani, Bruno; Iannone, Florenzo
2017-01-01
Behçet's disease (BD) is a multisystemic disorder of unknown etiology mainly defined by recurrent oral aphthosis, genital ulcers, and chronic relapsing bilateral uveitis, all of which represent the “stigmata” of disease. However, many other organs including the vascular, neurological, musculoskeletal, and gastrointestinal systems can be affected. The gastrointestinal involvement in Behçet's disease (GIBD), along with the neurological and vascular ones, represents the most feared clinical manifestation of BD and shares many symptoms with inflammatory bowel diseases, such as Crohn's disease and ulcerative colitis. Consequently, the differential diagnosis is often a daunting task, albeit the presence of typical endoscopic and pathologic findings may be a valuable aid to the exact diagnosis. To date, there are no standardized medical treatments for GIBD; therefore therapy should be tailored to the single patient and based on the severity of the clinical features and their complications. This work provides a digest of all current experience and evidence about pharmacological agents suggested by the medical literature as having a potential role for managing the dreadful features of GIBD. PMID:28210071
Bell's palsy during interferon alpha 2a treatment in a case with Behçet uveitis.
Yalçindağ, Fatime Nilüfer; Alay, Cem
2013-01-01
To present a case who developed Bell's palsy while using interferon alpha 2a for Behçet uveitis. A patient with Behçet disease presented with decreased vision in his right eye. Ophthalmic examination, fundus fluorescein angiography and optical coherence tomography were performed. After developing facial paralysis while on interferon therapy, the patient was referred to our neurology service for differential diagnosis and treatment. Examination of right eye revealed panuveitis with branch retinal vein occlusion, so high dose steroids were prescribed. In three days there was no improvement in terms of vitreous inflammation and so steroids were replaced with interferon. At the seventh month, patient experienced a facial paralysis. After eliminating other causes, including viral infections, trauma, cold exposure and neurological evaluation with cranial MRI, the patient was diagnosed to have Bell's palsy by a neurologist. Interferon was replaced with mycophenolate mofetil and the Bell's palsy was treated with oral steroids. It is important to be alert to both common and rare complications while treating with interferon.
Ulcerative colitis followed by the development of typical intestinal Behçet disease: A case report.
Zhu, Zhenhua; Shu, Xu; Long, Shunhua; Jiang, Xiaozhen; Lu, Nonghua; Zhu, Xuan; Liao, Wangdi
2018-02-01
Intestinal Behçet disease (intestinal BD) and inflammatory bowel disease (IBD) share a lot of characteristics, including genetic background, clinical manifestations, and therapeutic strategies, especially the extraintestinal manifestations, such as oral ulcers, arthralgia, eye lesions, skin lesions, etc, but the coexistence of these 2 diseases are uncommon. Behçet disease with gastrointestinal involvement in ulcerative colitis (UC) patient has been reported in just 1 previous case report, but, which can not be diagnosed as definite intestinal BD based on Korean novel diagnositic criteria due to lacking the typical ileocecal ulcer. We present a 23-year-old woman with ulcerative disease who developed typical intestinal BD, which is the first case report of patient with coexisting UC and typical intestinal BD. This patient was diagnosed as coexistence of intestinal BD and UC base on the clinical manifestations, extra intestinal manifestations and typical colonoscopic findings. Steroid and methotrexate were administered. This patient achieved clinical remission and mucosal healing. Coexistence of intestinal BD and UC is uncommon, and the combination with steroid, methotrexate, and 5-aminosalicylic acids is an effective therapy.
Wang, Shuya; Li, Ding; Pi, Jiaxin; Li, Wen; Zhang, Bing; Qi, Dongli; Li, Nan; Guo, Pan; Liu, Zhidong
2017-11-01
The purpose of this work was to determine and investigate the absorption of ginkgo terpenoids (GT) in plasma and aqueous humour after oral administration of ginkgo biloba extract (GBE) by UPLC-MS/MS method. The UPLC-MS/MS determination of GT employed the multiple reaction monitoring mode using an electrospray negative ionization. The rabbits were orally administered the suspension of GBE at a dose of 500 mg/kg. Serial plasma and dialysate samples were collected at the corresponding time and then analysed by UPLC-MS/MS. In plasma, the mean AUC from 0 to 48 h was 14.12, 12.59, 23.75, 1.51 h μg/ml for GLJ and 5.34 h μg/ml for GLA, GLB, GLC, GLJ and BLL, respectively. In aqueous humour, the five ginkgo terpenoids have been detected. Compared with the other four GT, BLL has better absorption in the eyes. A selective and reproducible UPLC-MS/MS method was developed and validated to determine and investigate the absorption of ginkgo terpenoids in plasma and aqueous humour of rabbits after oral administration of GBE. The main five ginkgo terpenoids could be absorbed into eyes. © 2017 Royal Pharmaceutical Society.
Zhang, Li; Shen, Hong; Xu, Jun; Xu, Jin-Di; Li, Zhen-Ling; Wu, Jie; Zou, Ye-Ting; Liu, Li-Fang; Li, Song-Lin
2018-04-25
In this study, a novel ultra-performance liquid chromatography coupled with quadrupole/time-of-flight mass spectrometry (UPLC-QTOF-MS/MS)-guidance strategy was proposed for preparation of sulfur-containing derivatives in sulfur-fumigated edible herbs. Being versatile in both chromatographic separation and mass spectrometric detection, UPLC-QTOF-MS/MS was inducted into each experimental step for multifaceted purposes including finding, tracking, purity determination and structural elucidation of targeted compounds as well as UPLC-HPLC chromatographic conditions transplantation, whereby the isolation and purification procedures were greatly facilitated. Using this strategy, a new sulfur-containing ginsenoside Rg 1 derivative (named compound I) was obtained from sulfur-fumigated ginseng. The chemical structure of compound I was elucidated to be (3β, 6α, 12β)-3, 12-dihydroxydammar-25-ene-6, 20-diylbis-β-d-glucopyranoside, 24-sulfonic acid by QTOF-MS/MS, 1 H-NMR and 13 C-NMR analysis, and its generation mechanisms by sulfur-fumigation were accordingly discussed. The research deliverable suggests that the UPLC-QTOF-MS/MS-guidance strategy is promising for targeted preparation of sulfur-containing derivatives from sulfur-fumigated edible herbs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Schmitz, E M H; Boonen, K; van den Heuvel, D J A; van Dongen, J L J; Schellings, M W M; Emmen, J M A; van der Graaf, F; Brunsveld, L; van de Kerkhof, D
2014-10-01
Three novel direct oral anticoagulants (DOACs) have recently been registered by the Food and Drug Administration and European Medicines Agency Commission: dabigatran, rivaroxaban, and apixaban. To quantify DOACs in plasma, various dedicated coagulation assays have been developed. To develop and validate a reference ultra-performance liquid chromatography - tandem mass spectrometry (UPLC-MS/MS) method and to evaluate the analytical performance of several coagulation assays for quantification of dabigatran, rivaroxaban, and apixaban. The developed UPLC-MS/MS method was validated by determination of precision, accuracy, specificity, matrix effects, lower limits of detection, carry-over, recovery, stability, and robustness. The following coagulation assays were evaluated for accuracy and precision: laboratory-developed (LD) diluted thrombin time (dTT), Hemoclot dTT, Pefakit PiCT, ECA, Liquid anti-Xa, Biophen Heparin (LRT), and Biophen DiXal anti-Xa. Agreement between the various coagulation assays and UPLC-MS/MS was determined with random samples from patients using dabigatran or rivaroxaban. The UPLC-MS/MS method was shown to be accurate, precise, sensitive, stable, and robust. The dabigatran coagulation assay showing the best precision, accuracy and agreement with the UPLC-MS/MS method was the LD dTT test. For rivaroxaban, the anti-factor Xa assays were superior to the PiCT-Xa assay with regard to precision, accuracy, and agreement with the reference method. For apixaban, the Liquid anti-Xa assay was superior to the PiCT-Xa assay. Statistically significant differences were observed between the various coagulation assays as compared with the UPLC-MS/MS reference method. It is currently unknown whether these differences are clinically relevant. When DOACs are quantified with coagulation assays, comparison with a reference method as part of proficiency testing is therefore pivotal. © 2014 International Society on Thrombosis and Haemostasis.
Heo, Seok; Yoo, Geum Joo; Choi, Ji Yeon; Park, Hyoung Joon; Do, Jung-Ah; Cho, Sooyeul; Baek, Sun Young; Park, Sung-Kwan
2016-06-01
The primary purpose of this study was to develop and validate a method based on UPLC with UV and UPLC-MS-MS for the simultaneous analysis of different cannabinoids and synthetic cannabinoids in food as well as in herbal and dietary supplements. The limits of detection and quantitation of the method ranged from 0.1 to 0.3 and 0.3 to 0.9 μg/mL by UPLC with UV, respectively. The coefficient of determination was >0.999; the intra- and interday precision of the method were 0.1-3.7 and 0.9-4.1%, respectively. The intra- and interday accuracy were 94.8-103.1 and 98.3-100.9%, respectively. The mean recoveries of nine cannabinoids obtained from tablet samples ranged from 81.1 to 105.4%. The mean extraction recoveries of nine target cannabinoids obtained from various types of samples (tablets, capsules, powders, liquids, cookies and candies) ranged from 82.26 to 112.40%. The relative standard deviation (RSD) of the stability of the prepared sample solutions was <1.80%. Identification and quantification of the nine cannabinoids were accomplished by ion spray UPLC-MS-MS using multiple reaction monitoring. The UPLC-MS-MS method was validated for linearity (R(2) > 0.99); the precision was 0.1-4.0% (intraday) and 0.1-2.8% (interday), and the accuracy was 98.0-103.5% (intraday) and 97.1-103.2% (interday). The mean extraction recoveries of six types of samples were 82.2-114.5% and the RSD of stability was <6.54%, complying with the established international guidelines. The results indicated that the method can be used for rapid and accurate screening of cannabinoids present in food. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Deng, Haishan; Shang, Erxin; Xiang, Bingren; Xie, Shaofei; Tang, Yuping; Duan, Jin-ao; Zhan, Ying; Chi, Yumei; Tan, Defei
2011-03-15
The stochastic resonance algorithm (SRA) has been developed as a potential tool for amplifying and determining weak chromatographic peaks in recent years. However, the conventional SRA cannot be applied directly to ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC/TOFMS). The obstacle lies in the fact that the narrow peaks generated by UPLC contain high-frequency components which fall beyond the restrictions of the theory of stochastic resonance. Although there already exists an algorithm that allows a high-frequency weak signal to be detected, the sampling frequency of TOFMS is not fast enough to meet the requirement of the algorithm. Another problem is the depression of the weak peak of the compound with low concentration or weak detection response, which prevents the simultaneous determination of multi-component UPLC/TOFMS peaks. In order to lower the frequencies of the peaks, an interpolation and re-scaling frequency stochastic resonance (IRSR) is proposed, which re-scales the peak frequencies via linear interpolating sample points numerically. The re-scaled UPLC/TOFMS peaks could then be amplified significantly. By introducing an external energy field upon the UPLC/TOFMS signals, the method of energy gain was developed to simultaneously amplify and determine weak peaks from multi-components. Subsequently, a multi-component stochastic resonance algorithm was constructed for the simultaneous quantitative determination of multiple weak UPLC/TOFMS peaks based on the two methods. The optimization of parameters was discussed in detail with simulated data sets, and the applicability of the algorithm was evaluated by quantitative analysis of three alkaloids in human plasma using UPLC/TOFMS. The new algorithm behaved well in the improvement of signal-to-noise (S/N) compared to several normally used peak enhancement methods, including the Savitzky-Golay filter, Whittaker-Eilers smoother and matched filtration. Copyright © 2011 John Wiley & Sons, Ltd.
Accurate ab initio quartic force fields for borane and BeH2
NASA Technical Reports Server (NTRS)
Martin, J. M. L.; Lee, Timothy J.
1992-01-01
The quartic force fields of BH3 and BeH2 have been computed ab initio using an augmented coupled cluster (CCSD(T)) method and basis sets of spdf and spdfg quality. For BH3, the computed spectroscopic constants are in very good agreement with recent experimental data, and definitively confirm misassignments in some older work, in agreement with recent ab initio studies. Using the computed spectroscopic constants, the rovibrational partition function for both molecules has been constructed using a modified direct numerical summation algorithm, and JANAF-style thermochemical tables are presented.
Reactive collisions of electrons with H2+ , HD+, BeH+, BeD+ and SH+
NASA Astrophysics Data System (ADS)
Pop, Nicolina; Iacob, Felix; Mezei, János Zsolt; Motapon, Ousmanou; Niyonzima, Sebastien; Kashinski, David O.; Talbi, Dahbia; Hickman, Albert Peet; Schneider, Ioan F.
2017-12-01
In numerous cold ionized gases the dissociative recombination (DR), the elastic collisions (EC), the vibrational excitation (VE) (inelastic collisions) and the vibrational de-excitation (VdE) (super-elastic collisions) of molecular cations with electrons are major elementary processes. Using a stepwise method based on the Multichannel Quantum Defect Theory (MQDT), cross sections and rate coefficients have been obtained for reactions induced on HD+, H2+, BeH+, BeD+ and SH+. Moreover, the relative importance of the different reaction mechanisms, direct vs. indirect and rotational vs. non-rotational, have been studied for these molecular systems.
Wang, Zhenlei; Jiang, Ji; Hu, Pei; Zhao, Qian
2017-02-01
Fotagliptin is a novel dipeptidyl peptidase IV inhibitor under clinical development for the treatment of Type II diabetes mellitus. The objective of this study was to develop and validate a specific and sensitive ultra-performance liquid chromatography (UPLC)-MS/MS method for simultaneous determination of fotagliptin and its two major metabolites in human plasma and urine. Methodology & results: After being pretreated using an automatized procedure, the plasma and urine samples were separated and detected using a UPLC-ESI-MS/MS method, which was validated following the international guidelines. A selective and sensitive UPLC-MS/MS method was first developed and validated for quantifying fotagliptin and its metabolite in human plasma and urine. The method was successfully applied to support the clinical study of fotagliptin in Chinese healthy subjects.
Mora, Leticia; Sentandreu, Miguel Angel; Toldrá, Fidel
2007-06-13
A new HPLC procedure based on hydrophilic interaction chromatography (HILIC) has been developed for the simultaneous determination of carnosine, anserine, balenine, creatine, and creatinine in meat. This is the first time that HILIC has been directly applied to the study of meat components, having the advantage of not requiring complex cleanup and/or sample derivatization procedures. The chromatographic separation has been developed using a silica column (4.6 x 150 mm, 3 microm), and the proposed methodology is simple, reliable, and fast (<13 min per sample). The method has been validated in terms of linearity, repeatability, reproducibility, and recovery and represents an interesting alternative to methods currently in use for determining the mentioned compounds and other polar substances. The detection limits are 5.64, 8.23, 3.66, 3.99, and 0.06 microg/mL for carnosine, anserine, balenine, creatine, and creatinine, respectively.
Singer, David; Kuhlmann, Julia; Muschket, Matthias; Hoffmann, Ralf
2010-08-01
The separation of isomeric phosphorylated peptides is challenging and often impossible for multiphosphorylated isomers using chromatographic and capillary electrophoretic methods. In this study we investigated the separation of a set of single-, double-, and triple-phosphorylated peptides (corresponding to the human tau protein) by ion-pair reversed-phase chromatography (IP-RPC) and hydrophilic interaction chromatography (HILIC). In HILIC both hydroxyl and aminopropyl stationary phases were tested with aqueous acetonitrile in order to assess their separation efficiency. The hydroxyl phase separated the phosphopeptides very well from the unphosphorylated analogue, while on the aminopropyl phase even isomeric phosphopeptides attained baseline separation. Thus, up to seven phosphorylated versions of a given tau domain were separated. Furthermore, the low concentration of an acidic ammonium formate buffer allowed an online analysis with electrospray ionization tandem mass spectrometry (ESI-MS/MS) to be conducted, enabling peptide sequencing and identification of phosphorylation sites.
Predicting the Retention Behavior of Specific O-Linked Glycopeptides.
Badgett, Majors J; Boyes, Barry; Orlando, Ron
2017-09-01
O -Linked glycosylation is a common post-translational modification that can alter the overall structure, polarity, and function of proteins. Reverse-phase (RP) chromatography is the most common chromatographic approach to analyze O -glycosylated peptides and their unmodified counterparts, even though this approach often does not provide adequate separation of these two species. Hydrophilic interaction liquid chromatography (HILIC) can be a solution to this problem, as the polar glycan interacts with the polar stationary phase and potentially offers the ability to resolve the peptide from its modified form(s). In this paper, HILIC is used to separate peptides with O - N -acetylgalactosamine ( O -GalNAc), O - N -acetylglucosamine ( O -GlcNAc), and O -fucose additions from their native forms, and coefficients representing the extent of hydrophilicity were derived using linear regression analysis as a means to predict the retention times of peptides with these modifications.
Badgett, Majors J; Boyes, Barry; Orlando, Ron
2018-02-16
A model that predicts retention for peptides using a HALO ® penta-HILIC column and gradient elution was created. Coefficients for each amino acid were derived using linear regression analysis and these coefficients can be summed to predict the retention of peptides. This model has a high correlation between experimental and predicted retention times (0.946), which is on par with previous RP and HILIC models. External validation of the model was performed using a set of H. pylori samples on the same LC-MS system used to create the model, and the deviation from actual to predicted times was low. Apart from amino acid composition, length and location of amino acid residues on a peptide were examined and two site-specific corrections for hydrophobic residues at the N-terminus as well as hydrophobic residues one spot over from the N-terminus were created. Copyright © 2017 Elsevier B.V. All rights reserved.
Predicting the Retention Behavior of Specific O-Linked Glycopeptides
Badgett, Majors J.; Boyes, Barry; Orlando, Ron
2017-01-01
O-Linked glycosylation is a common post-translational modification that can alter the overall structure, polarity, and function of proteins. Reverse-phase (RP) chromatography is the most common chromatographic approach to analyze O-glycosylated peptides and their unmodified counterparts, even though this approach often does not provide adequate separation of these two species. Hydrophilic interaction liquid chromatography (HILIC) can be a solution to this problem, as the polar glycan interacts with the polar stationary phase and potentially offers the ability to resolve the peptide from its modified form(s). In this paper, HILIC is used to separate peptides with O-N-acetylgalactosamine (O-GalNAc), O-N-acetylglucosamine (O-GlcNAc), and O-fucose additions from their native forms, and coefficients representing the extent of hydrophilicity were derived using linear regression analysis as a means to predict the retention times of peptides with these modifications. PMID:28785176
Mass spectrometric based approaches in urine metabolomics and biomarker discovery.
Khamis, Mona M; Adamko, Darryl J; El-Aneed, Anas
2017-03-01
Urine metabolomics has recently emerged as a prominent field for the discovery of non-invasive biomarkers that can detect subtle metabolic discrepancies in response to a specific disease or therapeutic intervention. Urine, compared to other biofluids, is characterized by its ease of collection, richness in metabolites and its ability to reflect imbalances of all biochemical pathways within the body. Following urine collection for metabolomic analysis, samples must be immediately frozen to quench any biogenic and/or non-biogenic chemical reactions. According to the aim of the experiment; sample preparation can vary from simple procedures such as filtration to more specific extraction protocols such as liquid-liquid extraction. Due to the lack of comprehensive studies on urine metabolome stability, higher storage temperatures (i.e. 4°C) and repetitive freeze-thaw cycles should be avoided. To date, among all analytical techniques, mass spectrometry (MS) provides the best sensitivity, selectivity and identification capabilities to analyze the majority of the metabolite composition in the urine. Combined with the qualitative and quantitative capabilities of MS, and due to the continuous improvements in its related technologies (i.e. ultra high-performance liquid chromatography [UPLC] and hydrophilic interaction liquid chromatography [HILIC]), liquid chromatography (LC)-MS is unequivocally the most utilized and the most informative analytical tool employed in urine metabolomics. Furthermore, differential isotope tagging techniques has provided a solution to ion suppression from urine matrix thus allowing for quantitative analysis. In addition to LC-MS, other MS-based technologies have been utilized in urine metabolomics. These include direct injection (infusion)-MS, capillary electrophoresis-MS and gas chromatography-MS. In this article, the current progresses of different MS-based techniques in exploring the urine metabolome as well as the recent findings in providing potentially diagnostic urinary biomarkers are discussed. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 36:115-134, 2017. © 2015 Wiley Periodicals, Inc.
Suicidal ideation among patients with Behçet's syndrome.
Saygin, Caner; Uzunaslan, Didem; Hatemi, Gulen; Hamuryudan, Vedat
2015-01-01
To evaluate the frequency of suicidal ideation among Behçet's syndrome (BS) patients compared to healthy and diseased controls and to delineate possible factors predicting an increase in suicidal ideation. We included consecutive BS patients attending our outpatient clinic, patients with ankylosing spondylitis (AS) and healthy hospital staff as controls. Suicidal ideation was assessed by a standard questionnaire. Linear regression was used to identify the factors associated with suicidal ideation, such as demographic and clinical features, drugs, disease activity assessed using the Behçet's disease current activity form (BDCAF) for BS patients and BASDAI for AS patients, Behçet's disease quality of life (BDQoL) and Beck depression inventory (BDI) score. We surveyed 303 BS patients, 52 AS patients and 106 healthy controls. Suicidal thoughts, as reflected by a positive response to the first three items of the questionnaire, were higher among BS patients with major organ involvement (42%) than those with mucocutaneous involvement (35%) and the control groups. There were significantly more BS patients with active major organ involvement who had thought to terminate their lives without plans within the last year (25.5%) compared to those with active mucocutaneous involvement (8.7%) and active AS patients (10%) (p=0.012). Patient-reported joint pain (β=-0.155, p=0.046), BDQoL (β=0.176, p=0.032), and BDI (β=0.017, p<0.0001) scores, suicidal thoughts before the onset of BS (β=-0.124, p=0.043), neurologic involvement (β=0.119, p=0.047) and past prednisone use (β=0.212, p=0.005) were independent predictors of suicidal thoughts. BS patients with major organ involvement have increased thoughts of suicide during the active stages of their disease. A number of risk factors could help physicians to identify patients with increased suicidal thoughts.
Senusi, Amal A; Ola, Dennis; Mather, Jan; Mather, John; Fortune, Farida
2017-01-01
Behçet's syndrome (BS) is a chronic multisystemic disorder. The complex pattern of BS symptoms can effect negatively on patients' quality of life. The aim of this study is to evaluate the influence of BS symptoms, oral health related lifestyles and employment status on Health Related Quality of Life (HRQoL). A questionnaire was mailed to a cohort of 641 adult members of the Behçet's Syndrome Society (BSS) and patients attending a Behçet's syndrome centre in the UK. Respondents gave information on socio-demographic characteristics, disease duration, current symptoms, symptom control, health related lifestyle, diet, smoking and alcohol, employment status and quality of life (the EQ-5D index). 315 out of 426 BS participants (Males: Females=136:179) were recruited. BS symptoms and EQ-5D score model (R=0.67 and R2=0.45) and standardised coefficients for symptoms were; arthropathy (-0.336), headache (-0.227), neurological problems (-0.135), pathergy reaction (-0.119) and skin lesions (-0.107) in decreasing order. This finding was similar to a 2009 study of the same cohort. Regression analysis of tobacco consumption revealed that tobacco use was a risk factor for decreasing the EQ-5D score (beta value = - 0.72, p=0.001). Using an effective mouthwash has a positive impact on HRQoL (beta value= 0.149 and p=0.012). The mean EQ-5D in patients who continued in employment and who were not receiving benefits was better compared to other sub groups. BS symptoms, employment status, a healthy lifestyle combined with a good oral health have a significant impact on the HRQoL of BS patients.
Adalimumab for treatment of severe Behçet's uveitis: a retrospective long-term follow-up study.
Interlandi, Emanuela; Leccese, Pietro; Olivieri, Ignazio; Latanza, Loredana
2014-01-01
Behçet's disease (BD) is a chronic multisystem inflammatory disorder associated to uveitis that may represent a serious sight-threatening condition. The purpose of the present study is to assess the effectiveness of adalimumab as new strategic therapeutic approach in patients affected by severe Behçet's uveitis. Clinical data from twelve selected patients (22 eyes) were retrospectively analysed. All patients received 40 mg of adalimumab subcutaneously, once every 2 weeks, in addition to traditional immunosuppressive on-going therapy and eight of them were switched to adalimumab after failure of infliximab therapy. Primary outcome measures included ocular inflammatory activity, frequency of uveitis attacks and steroid-sparing effect. Secondary outcomes were changes of best-corrected visual acuity (BCVA), impact on traditional immunosuppressive therapy and occurrence of adalimumab-related side effects. Mean age of patients (11 males and 1 female) at the onset of disease was 24.34 years (±8.62 SD). Ocular involvement resulted bilateral in 83% of cases and mainly consisted in panuveitis (68% of eyes). After mean follow-up of 21 months (±9.63 SD) all patients but one (92%) achieved uveitis remission with BCVA improvement at least in one eye. Average uveitis attacks decreased from 2 to 0,42 during adalimumab (p<0.001) and daily-steroid dose was tapered in all adalimumab responders up to suspension in seven of them. No patient developed related side effects during adalimumab administration. Our results demonstrate that adalimumab is a very effective and safe option for treatment of patients with severe and resistant Behçet's uveitis, providing an appropriate and long-term control of ocular inflammation.
Chemical Fingerprint Analysis and Quantitative Analysis of Rosa rugosa by UPLC-DAD.
Mansur, Sanawar; Abdulla, Rahima; Ayupbec, Amatjan; Aisa, Haji Akbar
2016-12-21
A method based on ultra performance liquid chromatography with a diode array detector (UPLC-DAD) was developed for quantitative analysis of five active compounds and chemical fingerprint analysis of Rosa rugosa . Ten batches of R. rugosa collected from different plantations in the Xinjiang region of China were used to establish the fingerprint. The feasibility and advantages of the used UPLC fingerprint were verified for its similarity evaluation by systematically comparing chromatograms with professional analytical software recommended by State Food and Drug Administration (SFDA) of China. In quantitative analysis, the five compounds showed good regression (R² = 0.9995) within the test ranges, and the recovery of the method was in the range of 94.2%-103.8%. The similarities of liquid chromatography fingerprints of 10 batches of R. rugosa were more than 0.981. The developed UPLC fingerprint method is simple, reliable, and validated for the quality control and identification of R. rugosa . Additionally, simultaneous quantification of five major bioactive ingredients in the R. rugosa samples was conducted to interpret the consistency of the quality test. The results indicated that the UPLC fingerprint, as a characteristic distinguishing method combining similarity evaluation and quantification analysis, can be successfully used to assess the quality and to identify the authenticity of R. rugosa .
Liu, Kuangyi; Song, Yonggui; Liu, Yali; Peng, Mi; Li, Hanyun; Li, Xueliang; Feng, Bingwei; Xu, Pengfei; Su, Dan
2017-05-30
Currently the pharmacokinetic (PK) research of herbal medicines is still limited and facing critical technical challenges on quantitative analysis of multi-components from biological matrices which often accompanied by lacking of authentic standards and low concentration. This present work contributes to the development of an integrated strategy for extensive pharmacokinetics assessments, and a selective and sensitive method independent of authentic standards for multi-components analysis based on the use of ultra-performance liquid chromatography/quadrupole-time-of-flight/MS E (UPLC-TOF-MS E ) and UPLC-TOF-MRM (rnhanced target). Initially, phytochemicals were identified by UPLC-TOF-MS E analysis, subsequently the identified components were matched with authentic standards and pre-classified, and UPLC-QTOF-MRM method optimized and developed. To guarantee reliable results, three rules are necessary: (1) detection with a mass error of less than 5ppm; (2) same class chemical compositions with structural high similarity between analytes with and without authentic reference substance; (3) a matching retention time between TOF-MRM mode and TOF-MS E within 0.2min. The developed and validated method was applied for the simultaneous determination of 12 lignans in rat plasma after administered with wine processed Schisandra Chinensis fructus (WPSCF) extract. Such an approach was found capable of providing extensive pharmacokinetic profiles of multi-components absorbed into blood after oral administrated with WPSCF extract. The results also indicated that significant difference in pharmacokinetics parameters of dibenzocyclooctadiene lignans was observed between schizandrin and gomisin compounds. For lignans, the absorption via gastrointestinal tract were all rapid and maintained relatively long retention time, especially for schisantherin A and schisantherin B with higher plasma exposure. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhao, Xia; Wang, Bo; Xie, Kaizhou; Liu, Jianyu; Zhang, Yangyang; Wang, Yajuan; Guo, Yawen; Zhang, Genxi; Dai, Guojun; Wang, Jinyu
2018-06-15
A high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method and an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determining eight coccidiostat (halofuginone, lasalocid, maduramicin, monensin, narasin, nigericin, robenidine and salinomycin) residues in beef were developed and compared. Samples were extracted with a mixture of acetic acid, acetonitrile and ethyl acetate and were then purified on a C 18 solid-phase extraction (SPE) column. The purified samples were analyzed by HPLC-MS/MS and UPLC-MS/MS, using 0.1% formic acid-water solution (A) and pure methanol (B) as the mobile phase. The samples were fractionated on a C 18 column using different gradient elution procedures, followed by qualitative analysis using a mass spectrometer operated in multiple reaction monitoring (MRM) mode with positive electrospray ionization; the external standard method was used for quantitation. At spiked levels that ranged from the limit of quantification (LOQ) to 100 μg/kg, the average recoveries were 71.96%-100.32% and 71.24%-89.24%, with relative standard deviations (RSDs) of 2.65%-12.38% and 2.98%-14.86% for UPLC-MS/MS and HPLC-MS/MS, respectively. The limits of detection (LODs) and LOQs of the eight coccidiostats were 0.14-0.32 μg/kg and 0.43-1.21 μg/kg, respectively, for UPLC-MS/MS analysis and 0.16-0.58 μg/kg and 0.53-1.92 μg/kg, respectively, for HPLC-MS/MS analysis. Both methods had good accuracy and precision, but UPLC-MS/MS had higher sensitivity than HPLC-MS/MS. Copyright © 2018 Elsevier B.V. All rights reserved.
Antihepatotoxic Effect and Metabolite Profiling of Panicum turgidum Extract via UPLC-qTOF-MS.
Farag, Mohamed A; El Fishawy, Ahlam M; El-Toumy, Sayed A; Amer, Khadiga F; Mansour, Ahmed M; Taha, Hala E
2016-07-01
Panicum turgidum , desert grass, has not reported any detailed phytochemical or biological study as yet. To establish P. turgidum secondary metabolite profile and to assess its antihepatotoxic effect. Ultra-performance liquid chromatography (UPLC) coupled to quadrupole high-resolution time of flight mass spectrometry (qTOF-MS) was used for large-scale secondary metabolites profiling in P. turgidum extract, alongside assessing median lethal dose (LD 50 ) and hepatoprotective effect against carbon tetrachloride (CCl 4 ) intoxication. A total of 39 metabolites were identified with flavonoids as the major class present as O/C -glycosides of luteolin, apigenin, isorhamnetin and naringenin, most of which are first time to be reported in Panicum sp. Antihepatotoxic effect of P. turgidum crude extract was revealed via improving several biochemical marker levels and mitigation against oxidative stress in the serum and liver tissues, compared with CCl4 intoxicated group and further confirmed by histopathological examination. This study reveals that P. turgidum , enriched in C -flavonoids, presents a novel source of safe antihepatotoxic agents and further demonstrates the efficacy of UPLC-MS metabolomics in the field of natural products drug discovery. UPLC coupled to qTOF-MS was used for large scale secondary metabolites profiling in P. turgidum .A total of 39 metabolites were identified with flavonoids amounting as the major metabolite class.Anti-hepatotoxic effect of P. turgidum extract was revealed via several biochemical markers and histopathological examination.This study reveals that P. turgidum , enriched in C -flavonoids, present a novel source of antihepatotoxic agents. Abbreviations used: UPLC: Ultra-performance liquid chromatography (UPLC), LD50: median lethal dose, MDA: malondialdehyde, GSH: glutathione reductase, CAT: catalase, SOD: superoxide dismutase, ALT: alanine aminotransferase, AST: aspartate aminotransferase, ALP: alkaline phosphatase, TG: triglycerides.
Antihepatotoxic Effect and Metabolite Profiling of Panicum turgidum Extract via UPLC-qTOF-MS
Farag, Mohamed A.; El Fishawy, Ahlam M.; El-Toumy, Sayed A.; Amer, Khadiga F.; Mansour, Ahmed M.; Taha, Hala E.
2016-01-01
Background: Panicum turgidum, desert grass, has not reported any detailed phytochemical or biological study as yet Objective: To establish P. turgidum secondary metabolite profile and to assess its antihepatotoxic effect Materials and Methods: Ultra-performance liquid chromatography (UPLC) coupled to quadrupole high-resolution time of flight mass spectrometry (qTOF-MS) was used for large-scale secondary metabolites profiling in P. turgidum extract, alongside assessing median lethal dose (LD50) and hepatoprotective effect against carbon tetrachloride (CCl4) intoxication Results: A total of 39 metabolites were identified with flavonoids as the major class present as O/C-glycosides of luteolin, apigenin, isorhamnetin and naringenin, most of which are first time to be reported in Panicum sp. Antihepatotoxic effect of P. turgidum crude extract was revealed via improving several biochemical marker levels and mitigation against oxidative stress in the serum and liver tissues, compared with CCl4 intoxicated group and further confirmed by histopathological examination. Conclusion: This study reveals that P. turgidum, enriched in C-flavonoids, presents a novel source of safe antihepatotoxic agents and further demonstrates the efficacy of UPLC-MS metabolomics in the field of natural products drug discovery. SUMMARY UPLC coupled to qTOF-MS was used for large scale secondary metabolites profiling in P. turgidum.A total of 39 metabolites were identified with flavonoids amounting as the major metabolite class.Anti-hepatotoxic effect of P. turgidum extract was revealed via several biochemical markers and histopathological examination.This study reveals that P. turgidum, enriched in C-flavonoids, present a novel source of antihepatotoxic agents. Abbreviations used: UPLC: Ultra-performance liquid chromatography (UPLC), LD50: median lethal dose, MDA: malondialdehyde, GSH: glutathione reductase, CAT: catalase, SOD: superoxide dismutase, ALT: alanine aminotransferase, AST: aspartate aminotransferase, ALP: alkaline phosphatase, TG: triglycerides. PMID:27761073
Reitzle, Lukas; Maier, Barbara; Stojanov, Silvia; Teupser, Daniel; Muntau, Ania C; Vogeser, Michael; Gersting, Søren W
2015-08-01
Mevalonate kinase deficiency, a rare autosomal recessive autoinflammatory disease, is caused by mutations in the MVK gene encoding mevalonate kinase (MK). MK catalyzes the phosphorylation of mevalonic acid to mevalonate-5-phosphate (MVAP) in the pathway of isoprenoid and sterol synthesis. The disease phenotype correlates with residual activity ranging from <0.5% for mevalonic aciduria to 1-7% for the milder hyperimmunoglobulinemia D and periodic fever syndrome (HIDS). Hence, assessment of loss-of-function requires high accuracy measurements. We describe a method using isotope dilution UPLC-MS/MS for precise and sensitive determination of MK activity. Wild-type MK and the variant V261A, which is associated with HIDS, were recombinantly expressed in Escherichia coli. Enzyme activity was determined by formation of MVAP over time quantified by isotope dilution UPLC-MS/MS. The method was validated according to the FDA Guidance for Bioanalytical Method Validation. Sensitivity for detection of MAVP by UPLC-MS/MS was improved by derivatization with butanol-HCl (LLOQ, 5.0 fmol) and the method was linear from 0.5 to 250 μmol/L (R(2) > 0.99) with a precision of ≥ 89% and an accuracy of ± 2.7%. The imprecision of the activity assay, including the enzymatic reaction and the UPLC-MS/MS quantification, was 8.3%. The variant V261A showed a significantly decreased activity of 53.1%. Accurate determination of MK activity was enabled by sensitive and reproducible detection of MVAP using UPLC-MS/MS. The novel method may improve molecular characterization of MVK mutations, provide robust genotype-phenotype correlations, and accelerate compound screening for drug candidates restoring variant MK activity. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Dinç, Erdal; Ertekin, Zehra Ceren
2016-01-01
An application of parallel factor analysis (PARAFAC) and three-way partial least squares (3W-PLS1) regression models to ultra-performance liquid chromatography-photodiode array detection (UPLC-PDA) data with co-eluted peaks in the same wavelength and time regions was described for the multicomponent quantitation of hydrochlorothiazide (HCT) and olmesartan medoxomil (OLM) in tablets. Three-way dataset of HCT and OLM in their binary mixtures containing telmisartan (IS) as an internal standard was recorded with a UPLC-PDA instrument. Firstly, the PARAFAC algorithm was applied for the decomposition of three-way UPLC-PDA data into the chromatographic, spectral and concentration profiles to quantify the concerned compounds. Secondly, 3W-PLS1 approach was subjected to the decomposition of a tensor consisting of three-way UPLC-PDA data into a set of triads to build 3W-PLS1 regression for the analysis of the same compounds in samples. For the proposed three-way analysis methods in the regression and prediction steps, the applicability and validity of PARAFAC and 3W-PLS1 models were checked by analyzing the synthetic mixture samples, inter-day and intra-day samples, and standard addition samples containing HCT and OLM. Two different three-way analysis methods, PARAFAC and 3W-PLS1, were successfully applied to the quantitative estimation of the solid dosage form containing HCT and OLM. Regression and prediction results provided from three-way analysis were compared with those obtained by traditional UPLC method. Copyright © 2015 Elsevier B.V. All rights reserved.
Hatemi, Gulen; Yazici, Yusuf; Yazici, Hasan
2013-05-01
Behçet's syndrome (BS) shows a peculiar distribution, with a much higher prevalence in countries along the ancient Silk Road compared with rest of the world. BS also seems to follow a more severe course in ethnic groups with higher prevalence. Diagnosis depends on clinical findings. Criteria sets may not help in patients with less frequent types of involvement. Management strategies should be modified according to the age and sex of the patient and the organs involved. Being a serious health problem in endemic areas, BS also attracts global attention as a model to study inflammatory diseases of unknown cause. Copyright © 2013 Elsevier Inc. All rights reserved.
Zhang, Lingshu; Xu, Yuan; Peng, Yun; Yan, Bing; Liu, Yi
2015-01-01
Behçet's disease (BD)-like syndrome is an extremely rare situation occurred after Mycobacterium tuberculosis infection and virus infection. We reported a 45-year-old woman who visited our hospital complaining of swollen left ankle, painful genital ulcer, redness in the left eye and skin rash on lower limbs. The patient had a history of pleural tuberculosis and had received anti-tuberculous therapy for one year. Her left cervical lymph node sample demonstrated tubercle bacilli DNA fragmentation. The diagnosis of tuberculous lymphadenitis and Behçet's disease (BD)-like syndrome were made. This patient's symptoms remitted following treatment with anti-tuberculous therapy. This case indicates that some microbial infection can trigger the onset of BD-like syndrome in genetically susceptible subjects. However, treatment strategy of BD-like syndrome secondary to infection is totally different from primary BD. The aim of this case report is to present our experience of the different clinical signs and treatment of BD-like syndrome to expedite its early diagnosis in future. Combination of clinical, radiological, immunophenotypic, pathological, and genetic data contribute to improving the rate of diagnosis.
Uygunoğlu, Uğur; Pasha, Maarya; Saip, Sabahattin; Siva, Aksel
2015-01-01
Spinal cord involvement is not common, but can be seen in neuro-Behçet's syndrome (NBS). The major site of involvement is the cervical spinal cord with the myelitis-like inflammatory lesions continuing more than two segments, and extending to the brainstem. A 30-year-old male patient who has been followed with a diagnosis of Behçet's syndrome admitted to our neurology department clinically and radiologically suggestive of recurrent and extensive longitudinal myelitis. His anti-aquaporine antibody was negative. Because of insufficient effect of azathioprine, cyclophosphamide, and corticosteroids, infliximab was started. His clinical and radiological status is stationary for 3 years under infliximab treatment. Myelitis such as that occurring in our patient may have a similar presentation like neuromyelitis optica (NMO), which should therefore be included in differential diagnosis. Myelitis observed in both NMO and NBS shows spinal cord lesions longer than three or more vertebrae. Anti-aquaporine antibody must be evaluated in all patients presenting with longitudinal myelitis. Anti-tumor necrosis factor agent infliximab might be an alternative treatment in severe form of NBS such as myelitis. In our case, successful treatment of recurrent and extensive longitudinal transverse myelitis in NBS with infliximab was demonstrated.
de Souza, Nathalia Leslie Albanez Rodrigues; Siqueira, Daniel Emílio Dalledone; Cantador, Alex Aparecido; Rossetti, Leandro Pablos; Molinari, Giovani José Dal Poggetto; Guillaumon, Ana Terezinha
2017-01-01
Resumo A doença de Behçet é uma doença sistêmica, multifatorial e autoimune com diversas manifestações clínicas, entre elas o acometimento vascular. Aneurisma de aorta associado a erosão de vértebra lombar é condição rara na literatura, existindo apenas quatro relatos de caso nas bases de dados da PubMed. O presente artigo relata o caso de paciente do sexo feminino com diagnóstico de Doença de Behçet de longa data e aneurisma sacular de aorta abdominal infrarrenal com erosão de vértebra lombar. O caso foi tratado por meio de técnica endovascular com colocação de endoprótese monoilíaca e enxerto fêmoro-femoral cruzado, devido a limitações anatômicas da bifurcação aórtica. O artigo aborda a raridade desse tipo de apresentação da doença e o desfecho do tratamento e apresenta revisão da literatura sobre esse tema. PMID:29930640
Ocular Behçet disease: current therapeutic approaches.
Evereklioglu, Cem
2011-11-01
To alert physician to timely recognition and current treatment of recurrent hypopyon iridocyclitis or panuveitis in ocular Behçet disease (OBD). Interferon-α, rituximab, intravitreal triamcinolone, and biological response modifiers by tumor necrosis factor inhibitors such as infliximab and adalimumab are being used increasingly for the treatment of severe sight-threatening ocular inflammation including retinal vasculitis and cystoid macular edema (CME). Biological agents offer tremendous potential in the treatment of OBD. Given that OBD predominantly afflicts the younger adults in their most productive years, dermatologist, rheumatologist, internist, or general practitioners supervising patients with oculo-articulo-oromucocutaneous syndromes should be aware of systemic Behçet disease. Early recognition of ocular involvement is important and such patients should strongly be instructed to visit immediately an ophthalmologist, as uveitis management differs from extraocular involvements with high ocular morbidity from sight-threatening complications due to relapsing inflammatory attacks in the posterior segment of the eye. A single infliximab infusion should be considered for the control of acute panuveitis, whereas repeated long-term infliximab infusions were proved to be more effective in reducing the number of episodes in refractory uveoretinitis with faster regression and complete remission of CME.
Rosenbaum, James T.; Sibley, Cailin H.; Lin, Phoebe
2016-01-01
Purpose of review Ophthalmologists and rheumatologists frequently miscommunicate in consulting on patients with retinal vasculitis. This report seeks to establish a common understanding of the term, retinal vasculitis, and to review recent papers on this diagnosis. Recent findings 1) The genetic basis of some rare forms of retinal vascular disease have recently been described. Identified genes include CAPN5, TREX1, and TNFAIP3; 2) Behçet’s disease is a systemic illness that is very commonly associated with occlusive retinal vasculitis; 3) retinal imaging including fluorescein angiography and other newer imaging modalities has proven crucial to the identification and characterization of retinal vasculitis and its complications; 4) although monoclonal antibodies to IL-17A or IL-1 beta failed in trials for Behçet’s disease, antibodies to TNF alpha, either infliximab or adalimumab, have demonstrated consistent benefit in managing this disease. Interferon treatment and B cell depletion therapy via rituximab may be beneficial in certain types of retinal vasculitis. Summary Retinal vasculitis is an important entity for rheumatologists to understand. Retinal vasculitis associated with Behçet’s disease responds to monoclonal antibodies that neutralize TNF, but the many other forms of non-infectious retinal vasculitis may require alternate therapeutic management. PMID:26945335
Aykutlu, E; Baykan, B; Akman-Demir, G; Topcular, B; Ertas, M
2006-02-01
The aim of this study was to investigate the characteristics of headache in patients with Behçet's disease (BD) seeking neurological consultation. Consecutive patients with BD seen within 1 year at the neuro-Behçet's out-patient clinic were studied using an electronic database according to the classification criteria of the International Headache Society. During a 12-month period 118 BD patients were admitted, and 98 had headaches. Migraine was the most common type of primary headache diagnosed in 45 patients (46.4%) in the whole headache group, followed by tension-type headache (TTH) in 26 cases (26.8%). Thirty-seven patients had secondary headaches mainly due to cerebral venous thrombosis or parenchymal neurological involvement of BD. Of these patients, 15 had both primary and secondary headaches. The primary headaches of 13 patients were exacerbated with systemic BD flare-ups, and four patients had migraine attacks triggered only by systemic BD activation which showed a good response to the treatment of systemic inflammation. The majority of the headaches of patients with BD do not indicate any neurological involvement; they are usually due to migraine or TTH. In a minority of patients, migraine associated with systemic inflammation of BD is notable.
ABO blood groups, Rhesus factor, and Behçet's disease.
Ozyurt, Kemal; Oztürk, Perihan; Gül, Mustafa; Benderli, Yasemin Cihan; Cölgeçen, Emine; Inci, Rahime
2013-09-01
Recently, numerous studies have been carried out to explain the genetics and immunopathogenesis of Behçet's disease (BD). There is still insufficient understanding of its etiopathogenesis, but substantial genetic and immune system abnormalities have been suggested. Several studies have shown remarkable associations of ABO blood groups with various diseases. This study investigated the relationship between ABO and Rhesus (D) blood groups and Behçet's disease in Turkish patients. Clinical data on gender, ABO, and Rhesus blood type of patients with BD were collected at the Kayseri Education and Research Hospital from 2005 to 2012. A total of 115 patients with BD were assessed for their association with ABO or Rhesus (D) blood groups and compared with the distribution of the blood groups of 25,701 healthy donors admitted to the Kayseri Education and Research Hospital Blood Center in 2010 and 2011. The distribution of ABO and Rhesus blood groups in patients with BD was similar to the healthy donors. No relationship was found between ABO or Rhesus blood groups and BD at our hospital. Further studies with a larger series and in different centers may be valuable for identifying the association between ABO or Rhesus (D) blood groups and BD.
Global Profiling of Various Metabolites in Platycodon grandiflorum by UPLC-QTOF/MS.
Lee, Jae Won; Ji, Seung-Heon; Kim, Geum-Soog; Song, Kyung-Sik; Um, Yurry; Kim, Ok Tae; Lee, Yi; Hong, Chang Pyo; Shin, Dong-Ho; Kim, Chang-Kug; Lee, Seung-Eun; Ahn, Young-Sup; Lee, Dae-Young
2015-11-09
In this study, a method of metabolite profiling based on UPLC-QTOF/MS was developed to analyze Platycodon grandiflorum. In the optimal UPLC, various metabolites, including major platycosides, were separated well in 15 min. The metabolite extraction protocols were also optimized by selecting a solvent for use in the study, the ratio of solvent to sample and sonication time. This method was used to profile two different parts of P. grandiflorum, i.e., the roots of P. grandiflorum (PR) and the stems and leaves of P. grandiflorum (PS), in the positive and negative ion modes. As a result, PR and PS showed qualitatively and quantitatively different metabolite profiles. Furthermore, their metabolite compositions differed according to individual plant samples. These results indicate that the UPLC-QTOF/MS-based profiling method is a good tool to analyze various metabolites in P. grandiflorum. This metabolomics approach can also be applied to evaluate the overall quality of P. grandiflorum, as well as to discriminate the cultivars for the medicinal plant industry.
Chen, Lin-Wei; Wang, Qin; Qin, Kun-Ming; Wang, Xiao-Li; Wang, Bin; Chen, Dan-Ni; Cai, Bao-Chang; Cai, Ting
2016-02-01
The present study was designed to develop and validate a sensitive and reliable ultra high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UPLC-QTOF/MS) method to separate and identify the chemical constituents of Qixue Shuangbu Tincture (QXSBT), a classic traditional Chinese medicine (TCM) prescription. Under the optimized UPLC and QTOF/MS conditions, 56 components in QXSBT, including chalcones, triterpenoids, protopanaxatriol, flavones and flavanones were identified and tentatively characterized within a running time of 42 min. The components were identified by comparing the retention times, accurate mass, and mass spectrometric fragmentation characteristic ions, and matching empirical molecular formula with that of the published compounds. In conclusion, the established UPLC-QTOF/MS method was reliable for a rapid identification of complicated components in the TCM prescriptions. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
Global Profiling of Various Metabolites in Platycodon grandiflorum by UPLC-QTOF/MS
Lee, Jae Won; Ji, Seung-Heon; Kim, Geum-Soog; Song, Kyung-Sik; Um, Yurry; Kim, Ok Tae; Lee, Yi; Hong, Chang Pyo; Shin, Dong-Ho; Kim, Chang-Kug; Lee, Seung-Eun; Ahn, Young-Sup; Lee, Dae-Young
2015-01-01
In this study, a method of metabolite profiling based on UPLC-QTOF/MS was developed to analyze Platycodon grandiflorum. In the optimal UPLC, various metabolites, including major platycosides, were separated well in 15 min. The metabolite extraction protocols were also optimized by selecting a solvent for use in the study, the ratio of solvent to sample and sonication time. This method was used to profile two different parts of P. grandiflorum, i.e., the roots of P. grandiflorum (PR) and the stems and leaves of P. grandiflorum (PS), in the positive and negative ion modes. As a result, PR and PS showed qualitatively and quantitatively different metabolite profiles. Furthermore, their metabolite compositions differed according to individual plant samples. These results indicate that the UPLC-QTOF/MS-based profiling method is a good tool to analyze various metabolites in P. grandiflorum. This metabolomics approach can also be applied to evaluate the overall quality of P. grandiflorum, as well as to discriminate the cultivars for the medicinal plant industry. PMID:26569219
Yang, Yuan-Gui; Zhang, Ji; Zhao, Yan-Li; Zhang, Jin-Yu; Wang, Yuan-Zhong
2017-07-01
A rapid method was developed and validated by ultra-performance liquid chromatography-triple quadrupole mass spectroscopy with ultraviolet detection (UPLC-UV-MS) for simultaneous determination of paris saponin I, paris saponin II, paris saponin VI and paris saponin VII. Partial least squares discriminant analysis (PLS-DA) based on UPLC and Fourier transform infrared (FT-IR) spectroscopy was employed to evaluate Paris polyphylla var. yunnanensis (PPY) at different harvesting times. Quantitative determination implied that the various contents of bioactive compounds with different harvesting times may lead to different pharmacological effects; the average content of total saponins for PPY harvested at 8 years was higher than that from other samples. The PLS-DA of FT-IR spectra had a better performance than that of UPLC for discrimination of PPY from different harvesting times. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Hu, Yuntao; Richter, Andreas; Wanek, Wolfgang
2016-04-01
Soil organic matter (SOM) decomposition is one of the most important processes of the global nitrogen cycle, having strong implications on soil N availability, terrestrial carbon cycling and soil carbon sequestration. During SOM decomposition low-molecular weight organic nitrogen (LMWON) is released which can be taken up by microbes (and plants). The breakdown of high-molecular weight organic nitrogen (HMWON, e.g. proteins, peptidoglycan, chitin, nucleic acids) represents the bottleneck of soil HMWON decomposition and is performed by extracellular enzymes released mainly by soil microorganisms. Despite that, the current understanding of the controls of these processes is incomplete. The only way to measure gross decomposition rates of these polymers is to use isotope pool dilution (IPD) techniques. In IPD approaches the product pool is isotopically enriched (by e.g. 15N) and the isotope dilution of this pool is measured over time. We have pioneered an IPD for protein and cellulose depolymerization, but IPD approaches for other polymers, specifically for important microbial necromass components such as chitin (fungi) and peptidoglycan (bacteria), or nucleic acids have not yet been developed. Here we present a workflow based on a universally applicable technical platform that allows to estimate the gross depolymerization rate of SOM (HMWON) at the molecular level, using ultra high performance liquid chromatography/high resolution Orbitrap mass spectrometry (UPLC/HRMS) combined with IPD techniques. The necessary isotopically labeled organic polymers (chitin, peptidoglycan and others) are extracted from laboratory bacterial and fungal cultures grown in fully isotopically labeled nutrient media (15N, 13C or both). A purification scheme for the different polymers is currently established. Labeled potential decomposition products (e.g. amino sugars and muropeptides from peptidoglycan, amino sugars and chitooligosaccharides from chitin, nucleotides and nucleosides from nucleic acids) are prepared by enzymatic and/or acid digestion of the polymers. Different UPLC separation columns (Hypercarb, HiliC and C18) make it possible to separate more than 100 related monomers and oligomers produced during polymer decomposition, a prerequisite for analyzing the concentrations and isotope kinetics of decomposition products in complex soil samples. The benchtop Orbitrap mass analyzer has a nominal mass resolving power of 100,000 (FWHM at m/z 200), which enables us to separate compounds that are 13C- and 15N-labelled (mass difference: 0.00632) in the same compound, allowing tracing carbon and nitrogen isotopes in the same compound in IPD experiments. With the accurate masses, retention times and the isotopic pattern we can quantify and qualify the target decomposition products and their isotope kinetics during soil incubation experiments. This will enable us to estimate in situ decomposition rates of the major organic nitrogen polymers in soils, allowing new insights into the major controls of the most important step in soil organic nitrogen recycling.
Dai, Sheng-Yun; Xu, Bing; Shi, Xin-Yuan; Xu, Xiang; Sun, Ying-Qiang; Qiao, Yan-Jiang
2017-03-01
This study is aimed to propose a continual improvement strategy based on quality by design (QbD). An ultra high performance liquid chromatography (UPLC) method was developed to accomplish the method transformation from HPLC to UPLC of Panax notogineng saponins (PNS) and achieve the continual improvement of PNS based on QbD, for example. Plackett-Burman screening design and Box-Behnken optimization design were employed to further understand the relationship between the critical method parameters (CMPs) and critical method attributes (CMAs). And then the Bayesian design space was built. The separation degree of the critical peaks (ginsenoside Rg₁ and ginsenoside Re) was over 2.0 and the analysis time was less than 17 min by a method chosen from the design space with 20% of the initial concentration of the acetonitrile, 10 min of the isocratic time and 6%•min⁻¹ of the gradient slope. At last, the optimum method was validated by accuracy profile. Based on the same analytical target profile (ATP), the comparison of HPLC and UPLC including chromatograph method, CMA identification, CMP-CMA model and system suitability test (SST) indicated that the UPLC method could shorten the analysis time, improve the critical separation and satisfy the requirement of the SST. In all, HPLC method could be replaced by UPLC for the quantity analysis of PNS. Copyright© by the Chinese Pharmaceutical Association.
Zang, Qing-Ce; Wang, Jia-Bo; Kong, Wei-Jun; Jin, Cheng; Ma, Zhi-Jie; Chen, Jing; Gong, Qian-Feng; Xiao, Xiao-He
2011-12-01
The fingerprints of artificial Calculus bovis extracts from different solvents were established by ultra-performance liquid chromatography (UPLC) and the anti-bacterial activities of artificial C. bovis extracts on Staphylococcus aureus (S. aureus) growth were studied by microcalorimetry. The UPLC fingerprints were evaluated using hierarchical clustering analysis. Some quantitative parameters obtained from the thermogenic curves of S. aureus growth affected by artificial C. bovis extracts were analyzed using principal component analysis. The spectrum-effect relationships between UPLC fingerprints and anti-bacterial activities were investigated using multi-linear regression analysis. The results showed that peak 1 (taurocholate sodium), peak 3 (unknown compound), peak 4 (cholic acid), and peak 6 (chenodeoxycholic acid) are more significant than the other peaks with the standard parameter estimate 0.453, -0.166, 0.749, 0.025, respectively. So, compounds cholic acid, taurocholate sodium, and chenodeoxycholic acid might be the major anti-bacterial components in artificial C. bovis. Altogether, this work provides a general model of the combination of UPLC chromatography and anti-bacterial effect to study the spectrum-effect relationships of artificial C. bovis extracts, which can be used to discover the main anti-bacterial components in artificial C. bovis or other Chinese herbal medicines with anti-bacterial effects. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yan, Xiaojing; Sun, Liangliang; Zhu, Guijie; Cox, Olivia F.; Dovichi, Norman J.
2016-01-01
A tryptic digest generated from Xenopus laevis fertilized embryos was fractionated by reversed phase liquid chromatography. One set of 30 fractions was analyzed by 100-min CZE-ESI-MS/MS separations (50 hr total instrument time), and a second set of 15 fractions was analyzed by 3-hr UPLC-ESI-MS/MS separations (45 hr total instrument time). CZE-MS/MS produced 70% as many protein IDs (4,134 vs. 5,787) and 60% as many peptide IDs (22,535 vs. 36,848) as UPLC-MS/MS with similar instrument time (50 h vs. 45 h) but with 50 times smaller total consumed sample amount (1.5 μg vs. 75 μg). Surprisingly, CZE generated peaks that were 25% more intense than UPLC for peptides that were identified by both techniques, despite the 50-fold lower loading amount; this high sensitivity reflects the efficient ionization produced by the electrokinetically-pumped nanospray interface used in CZE. This report is the first comparison of CZE-MS/MS and UPLC-MS/MS for large-scale eukaryotic proteomic analysis. The numbers of protein and peptide identifications produced by CZE-ESI-MS/MS approach those produced by UPLC-MS/MS, but with nearly two orders of magnitude lower sample amounts. PMID:27723263
Determination of anthelmintic drug residues in milk using UPLC-MS/MS with rapid polarity switching
USDA-ARS?s Scientific Manuscript database
A new UPLC-MS/MS (ultra-performance liquid chromatography coupled to tandem mass spectrometry) method was developed and validated to detect 38 anthelmintic drug residues, consisting of benzimidazoles, avermectins and flukicides. A modified QuEChERS-type extraction method was developed with an added...
Kalogria, Eleni; Pistos, Constantinos; Panderi, Irene
2013-12-30
A hydrophilic interaction liquid chromatography/positive ion electrospray-mass spectrometry (HILIC-ESI/MS) has been developed and fully validated for the quantification of alprazolam and its main metabolite, α-hydroxy-alprazolam, in human plasma. The assay is based on 50μL plasma samples, following liquid-liquid extraction. All analytes and the internal standard (tiamulin) were separated by hydrophilic interaction liquid chromatography using an X-Bridge-HILIC analytical column (150.0mm×2.1mm i.d., particle size 3.5μm) under isoscratic elution. The mobile phase was composed of a 7% 10mM ammonium formate water solution in acetonitrile and pumped at a flow rate of 0.20mLmin(-1). Running in positive electrospray ionization and selected ion monitoring (SIM) the mass spectrometer was set to analyze the protonated molecules [M+H](+) at m/z 309, 325 and 494 for alprazolam, α-hydroxy-alprazolam and tiamulin (ISTD) respectively. The assay was linear over the concentration range of 2.5-250ngmL(-1) for alprazolam and 2.5-50ngmL(-1) for α-hydroxy alprazolam. Intermediate precision was less than 4.1% over the tested concentration ranges. The method is the first reported application of HILIC in the analysis benzodiazepines in human plasma. With a small sample size (50μL human plasma) and a run time less than 10.0min for each sample the method can be used to support a wide range of clinical studies concerning alprazolam quantification. Copyright © 2013 Elsevier B.V. All rights reserved.
Maksić, Jelena; Tumpa, Anja; Stajić, Ana; Jovanović, Marko; Rakić, Tijana; Jančić-Stojanović, Biljana
2016-05-10
In this paper separation of granisetron and its two related substances in HILIC mode is presented. Separation was done on silica column derivatized with sulfoalkylbetaine groups (ZIC-HILIC). Firstly, retention mechanisms were assessed whereby retention factors of substances were followed in wide range of acetonitrile content (80-97%), at constant concentration of aqueous buffer (10mM) as well as at constant pH value of 3.0. Further, in order to developed optimal HILIC method, Design of Experiments (DoE) methodology was applied. For optimization full factorial design 3(2) was employed. Influence of acetonitrile content and ammonium acetate concentration were investigated while pH of the water phase was kept at 3.3. Adequacy of obtained mathematical models was confirmed by ANOVA. Optimization goals (α>1.15 and minimal run time) were accomplished with 94.7% of acetonitrile in mobile phase and 70 mM of ammonium acetate in water phase. Optimal point was in the middle of defined Design Space. In the next phase, robustness was experimetally tested by Rechtschaffen design. The investigated factors and their levels were: acetonitrile content (±1%), ammonium acetate molarity in water phase (±2 mM), pH value of water phase (±0.2) and column temperature (±4 °C). The validation scope included selectivity, linearity, accuracy and precision as well as determination of limit of detection (LOD) and limit of quantification (LOQ) for the related substances. Additionally, the validation acceptance criteria were met in all cases. Finally, the proposed method could be successfully utilized for estimation of granisetron HCl and its related substances in tablets and parenteral dosage forms, as well as for monitoring degradation under various stress conditions. Copyright © 2016 Elsevier B.V. All rights reserved.
Baker, Teesha C; Tymm, Fiona J M; Murch, Susan J
2018-01-01
β-N-Methylamino-L-alanine (BMAA) is a naturally occurring non-protein amino acid produced by cyanobacteria, accumulated through natural food webs, found in mammalian brain tissues. Recent evidence indicates an association between BMAA and neurological disease. The accurate detection and quantification of BMAA in food and environmental samples are critical to understanding BMAA metabolism and limiting human exposure. To date, there have been more than 78 reports on BMAA in cyanobacteria and human samples, but different methods give conflicting data and divergent interpretations in the literature. The current work was designed to determine whether orthogonal chromatography and mass spectrometry methods give consistent data interpretation from a single sample matrix using the three most common analytical methods. The methods were recreated as precisely as possible from the literature with optimization of the mass spectrometry parameters specific to the instrument. Four sample matrices, cyanobacteria, human brain, blue crab, and Spirulina, were analyzed as 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) derivatives, propyl chloroformate (PCF) derivatives separated by reverse phase chromatography, or underivatized extracts separated by HILIC chromatography. The three methods agreed on positive detection of BMAA in cyanobacteria and no detected BMAA in the sample of human brain matrix. Interpretation was less clear for a sample of blue crab which was strongly positive for BMAA by AQC and PCF but negative by HILIC and for four spirulina raw materials that were negative by PCF but positive by AQC and HILIC. Together, these data demonstrate that the methods gave different results and that the choices in interpretation of the methods determined whether BMAA was detected. Failure to detect BMAA cannot be considered proof of absence.
Boudah, Samia; Olivier, Marie-Françoise; Aros-Calt, Sandrine; Oliveira, Lydie; Fenaille, François; Tabet, Jean-Claude; Junot, Christophe
2014-09-01
This work aims at evaluating the relevance and versatility of liquid chromatography coupled to high resolution mass spectrometry (LC/HRMS) for performing a qualitative and comprehensive study of the human serum metabolome. To this end, three different chromatographic systems based on a reversed phase (RP), hydrophilic interaction chromatography (HILIC) and a pentafluorophenylpropyl (PFPP) stationary phase were used, with detection in both positive and negative electrospray modes. LC/HRMS platforms were first assessed for their ability to detect, retain and separate 657 metabolite standards representative of the chemical families occurring in biological fluids. More than 75% were efficiently retained in either one LC-condition and less than 5% were exclusively retained by the RP column. These three LC/HRMS systems were then evaluated for their coverage of serum metabolome. The combination of RP, HILIC and PFPP based LC/HRMS methods resulted in the annotation of about 1328 features in the negative ionization mode, and 1358 in the positive ionization mode on the basis of their accurate mass and precise retention time in at least one chromatographic condition. Less than 12% of these annotations were shared by the three LC systems, which highlights their complementarity. HILIC column ensured the greatest metabolome coverage in the negative ionization mode, whereas PFPP column was the most effective in the positive ionization mode. Altogether, 192 annotations were confirmed using our spectral database and 74 others by performing MS/MS experiments. This resulted in the formal or putative identification of 266 metabolites, among which 59 are reported for the first time in human serum. Copyright © 2014 Elsevier B.V. All rights reserved.
Naser, Fuad J; Mahieu, Nathaniel G; Wang, Lingjue; Spalding, Jonathan L; Johnson, Stephen L; Patti, Gary J
2018-02-01
Although it is common in untargeted metabolomics to apply reversed-phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC) methods that have been systematically optimized for lipids and central carbon metabolites, here we show that these established protocols provide poor coverage of semipolar metabolites because of inadequate retention. Our objective was to develop an RPLC approach that improved detection of these metabolites without sacrificing lipid coverage. We initially evaluated columns recently released by Waters under the CORTECS line by analyzing 47 small-molecule standards that evenly span the nonpolar and semipolar ranges. An RPLC method commonly used in untargeted metabolomics was considered a benchmarking reference. We found that highly nonpolar and semipolar metabolites cannot be reliably profiled with any single method because of retention and solubility limitations of the injection solvent. Instead, we optimized a multiplexed approach using the CORTECS T3 column to analyze semipolar compounds and the CORTECS C 8 column to analyze lipids. Strikingly, we determined that combining these methods allowed detection of 41 of the total 47 standards, whereas our reference RPLC method detected only 10 of the 47 standards. We then applied credentialing to compare method performance at the comprehensive scale. The tandem method showed more than a fivefold increase in credentialing coverage relative to our RPLC benchmark. Our results demonstrate that comprehensive coverage of metabolites amenable to reversed-phase separation necessitates two reconstitution solvents and chromatographic methods. Thus, we suggest complementing HILIC methods with a dual T3 and C 8 RPLC approach to increase coverage of semipolar metabolites and lipids for untargeted metabolomics. Graphical abstract Analysis of semipolar and nonpolar metabolites necessitates two reversed-phase chromatography (RPLC) methods, which extend metabolome coverage more than fivefold for untargeted profiling. HILIC hydrophilic interaction liquid chromatography.
Comprehensive Optimization of LC-MS Metabolomics Methods Using Design of Experiments (COLMeD).
Rhoades, Seth D; Weljie, Aalim M
2016-12-01
Both reverse-phase and HILIC chemistries are deployed for liquid-chromatography mass spectrometry (LC-MS) metabolomics analyses, however HILIC methods lag behind reverse-phase methods in reproducibility and versatility. Comprehensive metabolomics analysis is additionally complicated by the physiochemical diversity of metabolites and array of tunable analytical parameters. Our aim was to rationally and efficiently design complementary HILIC-based polar metabolomics methods on multiple instruments using Design of Experiments (DoE). We iteratively tuned LC and MS conditions on ion-switching triple quadrupole (QqQ) and quadrupole-time-of-flight (qTOF) mass spectrometers through multiple rounds of a workflow we term COLMeD (Comprehensive optimization of LC-MS metabolomics methods using design of experiments). Multivariate statistical analysis guided our decision process in the method optimizations. LC-MS/MS tuning for the QqQ method on serum metabolites yielded a median response increase of 161.5% (p<0.0001) over initial conditions with a 13.3% increase in metabolite coverage. The COLMeD output was benchmarked against two widely used polar metabolomics methods, demonstrating total ion current increases of 105.8% and 57.3%, with median metabolite response increases of 106.1% and 10.3% (p<0.0001 and p<0.05 respectively). For our optimized qTOF method, 22 solvent systems were compared on a standard mix of physiochemically diverse metabolites, followed by COLMeD optimization, yielding a median 29.8% response increase (p<0.0001) over initial conditions. The COLMeD process elucidated response tradeoffs, facilitating improved chromatography and MS response without compromising separation of isobars. COLMeD is efficient, requiring no more than 20 injections in a given DoE round, and flexible, capable of class-specific optimization as demonstrated through acylcarnitine optimization within the QqQ method.
Li, Chunmei; Jin, Fen; Yu, Zhiyong; Qi, Yamei; Shi, Xiaomei; Wang, Miao; Shao, Hua; Jin, Maojun; Wang, Jing; Yang, Mingqi
2012-07-11
A rapid method for analyzing trace levels of chlormequat (CQ) in meat samples by hydrophilic interaction liquid chromatography (HILIC)-electrospray tandem mass spectrometry was developed. The samples were extracted with acetonitrile, followed by a rapid cleanup through a dispersive solid-phase extraction (DSPE) technique with octadecyl (C18) DSPE sorbents. The chromatographic separation was achieved within 6 min using a HILIC column with 10 mM ammonium acetate and 0.1% (v/v) formic acid in water/acetonitrile (v/v, 40:60) as the mobile phase. Quantification was performed using a matrix-matched calibration curve, which was linear in the range of the 0.05-100 μg/L. The limit of detection (LOD) was estimated at 0.03 μg/kg for CQ on the basis of a peak to peak signal noise (S/N = 3). The limit of quantification (LOQ) was 0.1 μg/kg on the basis of the lowest spiked concentration with suitable precision and accuracy. The average recovery of CQ in spiked meat samples was 86.4-94.7% at 2, 20, and 200 μg/kg. Finally, this method was applied to determine CQ in the livestock and poultry meats purchased from markets in Beijing in 2011. CQ was detected in all 12 samples, and the concentration was 0.4-636.0 μg/kg. Concentrations in a chicken sample (636.0 μg/kg) and a goat meat sample (486.0 μg/kg) were found to be 15.9 and 2.43 times the corresponding Codex maximum residue limits, respectively.
Comprehensive Optimization of LC-MS Metabolomics Methods Using Design of Experiments (COLMeD)
Rhoades, Seth D.
2017-01-01
Introduction Both reverse-phase and HILIC chemistries are deployed for liquid-chromatography mass spectrometry (LC-MS) metabolomics analyses, however HILIC methods lag behind reverse-phase methods in reproducibility and versatility. Comprehensive metabolomics analysis is additionally complicated by the physiochemical diversity of metabolites and array of tunable analytical parameters. Objective Our aim was to rationally and efficiently design complementary HILIC-based polar metabolomics methods on multiple instruments using Design of Experiments (DoE). Methods We iteratively tuned LC and MS conditions on ion-switching triple quadrupole (QqQ) and quadrupole-time-of-flight (qTOF) mass spectrometers through multiple rounds of a workflow we term COLMeD (Comprehensive optimization of LC-MS metabolomics methods using design of experiments). Multivariate statistical analysis guided our decision process in the method optimizations. Results LC-MS/MS tuning for the QqQ method on serum metabolites yielded a median response increase of 161.5% (p<0.0001) over initial conditions with a 13.3% increase in metabolite coverage. The COLMeD output was benchmarked against two widely used polar metabolomics methods, demonstrating total ion current increases of 105.8% and 57.3%, with median metabolite response increases of 106.1% and 10.3% (p<0.0001 and p<0.05 respectively). For our optimized qTOF method, 22 solvent systems were compared on a standard mix of physiochemically diverse metabolites, followed by COLMeD optimization, yielding a median 29.8% response increase (p<0.0001) over initial conditions. Conclusions The COLMeD process elucidated response tradeoffs, facilitating improved chromatography and MS response without compromising separation of isobars. COLMeD is efficient, requiring no more than 20 injections in a given DoE round, and flexible, capable of class-specific optimization as demonstrated through acylcarnitine optimization within the QqQ method. PMID:28348510
Themelis, Thomas; Gotti, Roberto; Gatti, Rita
2017-10-25
Amino acids playing important roles in metabolic processes are often included in dietary supplements whose use has largely expanded over the last 20 years not only in patients with particular deficiencies, but also in athletes and even common people that want to enrich their regular daily diet. In the present study, a bare silica Kinetex core-shell 2.6μm HILIC column was used for separation of some important hydrophilic amino acids and amino acids-like molecules i.e., aspartic acid, creatine, carnitine, arginine and the tripeptide glutathione (GSH), by optimizing the chromatographic conditions for their determination in complex alimentary supplements. The contribution of partition, adsorption and ion exchange on the retention mechanism was studied by varying parameters such as water content and the counter-ion concentration in the mobile phase. Optimum conditions employed a Phenomenex Kinetex core-shell 2.6μm HILIC (100×4.6mm i.d.) column and a mobile phase of acetonitrile/potassium phosphate buffer (12.5mM; pH=2.8) 85:15, v/v, at the flow rate of 1.4mL/min, using UV detection at 200nm. A reference HPLC method for the selective determination of GSH by using 1,4-naphthoquinone as derivatization reagent was also introduced for comparative purposes. The developed HILIC method was validated and applied to the analysis of the considered compounds in dietary supplements. Interestingly, in some of the real samples, oxidized glutathione which is an inactive impurity of GSH, was found at the level of about 20%. The proposed study confirms the importance of simple analytical methods for a rigorous quality control of dietary supplements containing unstable active ingredients. Copyright © 2017 Elsevier B.V. All rights reserved.
Balog, Crina I A; Stavenhagen, Kathrin; Fung, Wesley L J; Koeleman, Carolien A; McDonnell, Liam A; Verhoeven, Aswin; Mesker, Wilma E; Tollenaar, Rob A E M; Deelder, André M; Wuhrer, Manfred
2012-09-01
Colorectal cancer is the third most common cancer worldwide with an annual incidence of ~1 million cases and an annual mortality rate of ~655,000 individuals. There is an urgent need for identifying novel targets to develop more sensitive, reliable, and specific tests for early stage detection of colon cancer. Post-translational modifications are known to play an important role in cancer progression and immune surveillance of tumors. In the present study, we compared the N-glycan profiles from 13 colorectal cancer tumor tissues and corresponding control colon tissues. The N-glycans were enzymatically released, purified, and labeled with 2-aminobenzoic acid. Aliquots were profiled by hydrophilic interaction liquid chromatography (HILIC-HPLC) with fluorescence detection and by negative mode MALDI-TOF-MS. Using partial least squares discriminant analysis to investigate the N-glycosylation changes in colorectal cancer, an excellent separation and prediction ability were observed for both HILIC-HPLC and MALDI-TOF-MS data. For structure elucidation, information from positive mode ESI-ion trap-MS/MS and negative mode MALDI-TOF/TOF-MS was combined. Among the features with a high separation power, structures containing a bisecting GlcNAc were found to be decreased in the tumor, whereas sulfated glycans, paucimannosidic glycans, and glycans containing a sialylated Lewis type epitope were shown to be increased in tumor tissues. In addition, core-fucosylated high mannose N-glycans were detected in tumor samples. In conclusion, the combination of HILIC and MALDI-TOF-MS profiling of N-glycans with multivariate statistical analysis demonstrated its potential for identifying N-glycosylation changes in colorectal cancer tissues and provided new leads that might be used as candidate biomarkers.
N-glycosylation of Colorectal Cancer Tissues
Balog, Crina I. A.; Stavenhagen, Kathrin; Fung, Wesley L. J.; Koeleman, Carolien A.; McDonnell, Liam A.; Verhoeven, Aswin; Mesker, Wilma E.; Tollenaar, Rob A. E. M.; Deelder, André M.; Wuhrer, Manfred
2012-01-01
Colorectal cancer is the third most common cancer worldwide with an annual incidence of ∼1 million cases and an annual mortality rate of ∼655,000 individuals. There is an urgent need for identifying novel targets to develop more sensitive, reliable, and specific tests for early stage detection of colon cancer. Post-translational modifications are known to play an important role in cancer progression and immune surveillance of tumors. In the present study, we compared the N-glycan profiles from 13 colorectal cancer tumor tissues and corresponding control colon tissues. The N-glycans were enzymatically released, purified, and labeled with 2-aminobenzoic acid. Aliquots were profiled by hydrophilic interaction liquid chromatography (HILIC-HPLC) with fluorescence detection and by negative mode MALDI-TOF-MS. Using partial least squares discriminant analysis to investigate the N-glycosylation changes in colorectal cancer, an excellent separation and prediction ability were observed for both HILIC-HPLC and MALDI-TOF-MS data. For structure elucidation, information from positive mode ESI-ion trap-MS/MS and negative mode MALDI-TOF/TOF-MS was combined. Among the features with a high separation power, structures containing a bisecting GlcNAc were found to be decreased in the tumor, whereas sulfated glycans, paucimannosidic glycans, and glycans containing a sialylated Lewis type epitope were shown to be increased in tumor tissues. In addition, core-fucosylated high mannose N-glycans were detected in tumor samples. In conclusion, the combination of HILIC and MALDI-TOF-MS profiling of N-glycans with multivariate statistical analysis demonstrated its potential for identifying N-glycosylation changes in colorectal cancer tissues and provided new leads that might be used as candidate biomarkers. PMID:22573871
Coexistence of Guillain-Barré syndrome and Behçet's disease.
Shugaiv, Erkingul; Kiyat-Atamer, Asli; Tüzün, Erdem; Deymeer, Feza; Oflazer, Piraye; Parman, Yesim; Akman-Demir, Gulsen
2013-01-01
Behçet's disease (BD) is a multisystemic, recurrent and inflammatory disorder. Neurological involvement is rare and affects mainly the central nervous system (CNS) in the form of brainstem meningoencephalitis or dural sinus thrombosis. Peripheral neuropathy is usually not observed during the course of BD but some reports have shown electrophysiologic evidence of subclinical neuropathy, mononeuritis multiplex and cranial neuropathy in BD patients. The co-occurrence of Guillain-Barré syndrome (GBS), an acute inflammatory demyelinating neuropathy, with other autoimmune or systemic diseases is rare. We present a case of BD with clinical and electrophysiological diagnosis of GBS. The findings of the patient were discussed with reference to literature.
Recurrent Pulmonary Aneurysms: Hughes-Stovin Syndrome on the Spectrum of Behçet Disease.
Bennji, Sami M; du Preez, Leonard; Griffith-Richards, Stephanie; Smit, Derrick P; Rigby, Jonathan; Koegelenberg, Coenraad F N; Irusen, Elvis M; Allwood, Brian W
2017-11-01
In this report, we describe a male patient who presented with recurrent life-threatening hemoptysis due to the sequential formation of multiple pulmonary aneurysms. Both pulmonary artery coil embolization and right lower lobectomy were performed, with limited success. The patient experienced extensive bilateral femoral DVT extending into the inferior vena cava, with massive hemoptysis, fulfilling the diagnosis of Hughes-Stovin syndrome. A final diagnosis of Behçet disease was made following extensive investigation, and the patient responded well to prednisone 20 mg orally and azathioprine 100 mg orally. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Shen, Qing; Dai, Zhiyuan; Huang, Yao-Wen; Cheung, Hon-Yeung
2016-08-15
Dried seahorse is a precious raw food material for cooking soups. In this study, a lipidomics strategy using the techniques of solid-phase extraction (SPE) and hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-QTOF/MS) was developed for extraction, visualization, and quantification of phospholipids in dried seahorses. The parameters of SPE were optimized, and 1 mL of sample and chloroform/methanol (1:2, v/v) were found to be the best loading volume and eluting solvent, respectively. Afterwards, each phospholipid class was successfully separated on a HILIC column and analyzed by mass spectrometry. A total of 50 phospholipid molecular species were identified and determined, including 15 phosphatidylcholines (PCs), 14 phosphatidylethanolamines (PEs), 12 phosphatidylinositols (PIs) and 9 phosphatidylserines (PSs). In comparison to previously methods, this strategy was robust and efficient in extraction, characterization, and determination of phospholipids. The dried seahorse was found to contain large amounts of polyunsaturated fatty acyl phospholipids which are beneficial to human health. Copyright © 2016 Elsevier Ltd. All rights reserved.
Silica, hybrid silica, hydride silica and non-silica stationary phases for liquid chromatography.
Borges, Endler M
2015-04-01
Free silanols on the surface of silica are the "villains", which are responsible for detrimental interactions of those compounds and the stationary phase (i.e., bad peak shape, low efficiency) as well as low thermal and chemical stability. For these reasons, we began this review describing new silica and hybrid silica stationary phases, which have reduced and/or shielded silanols. At present, in liquid chromatography for the majority of analyses, reversed-phase liquid chromatography is the separation mode of choice. However, the needs for increased selectivity and increased retention of hydrophilic bases have substantially increased the interest in hydrophilic interaction chromatography (HILIC). Therefore, stationary phases and this mode of separation are discussed. Then, non-silica stationary phases (i.e., zirconium oxide, titanium oxide, alumina and porous graphitized carbon), which afford increased thermal and chemical stability and also selectivity different from those obtained with silica and hybrid silica, are discussed. In addition, the use of these materials in HILIC is also reviewed. © Crown copyright 2014.
Viidanoja, Jyrki
2015-09-15
A new, sensitive and selective liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS/MS) method was developed for the analysis of Phospholipids (PLs) in bio-oils and fats. This analysis employs hydrophilic interaction liquid chromatography-scheduled multiple reaction monitoring (HILIC-sMRM) with a ZIC-cHILIC column. Eight PL class selective internal standards (homologs) were used for the semi-quantification of 14 PL classes for the first time. More than 400 scheduled MRMs were used for the measurement of PLs with a run time of 34min. The method's performance was evaluated for vegetable oil, animal fat and algae oil. The averaged within-run precision and between-run precision were ≤10% for all of the PL classes that had a direct homologue as an internal standard. The method accuracy was generally within 80-120% for the tested PL analytes in all three sample matrices. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai
2017-01-01
In this paper, by coupling reversed phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC), a two-dimensional liquid chromatography system was developed for separation and identification of the active ingredients in Gardenia jasminoides Ellis (GJE). By applying the semi-preparative C18 column as the first dimension and the core-shell column as the second dimension, a total of 896 peaks of GJE were separated. Among the 896 peaks, 16 active ingredients including geniposide, gardenoside, gardoside, etc. were identified by mass spectrometry analysis. The results indicated that the proposed two-dimensional RPLC/HILIC system was an effective method for the analysis of GJE and might hold a high potential to become a useful tool for analysis of other complex mixtures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Peng, Minzhi; Liu, Li; Jiang, Minyan; Liang, Cuili; Zhao, Xiaoyuan; Cai, Yanna; Sheng, Huiying; Ou, Zhiying; Luo, Hong
2013-08-01
Measurement of carnitine and acylcarnitines in plasma is important in diagnosis of fatty acid β-oxidation disorders and organic acidemia. The usual method uses flow injection tandem mass spectrometry (FIA-MS/MS), which has limitations. A rapid and more accurate method was developed to be used for high-risk screening and diagnosis. Carnitine and acylcarnitines were separated by hydrophilic interaction liquid chromatography (HILIC) without derivatization and detected with a QTRAP MS/MS System. Total analysis time was 9.0min. The imprecision of within- and between-run were less than 6% and 17%, respectively. Recoveries were in the range of 85-110% at three concentrations. Some acylcarnitine isomers could be separated, such as dicarboxylic and hydroxyl acylcarnitines. The method could also separate interferent to avoid false positive results. 216 normal samples and 116 patient samples were detected with the validated method, and 49 patients were identified with fatty acid oxidation disorders or organic acidemias. Copyright © 2013 Elsevier B.V. All rights reserved.
Objective is to develop analytical methods including SPE and UPLC/MS/MS needed to analyze over 60 human prescription pharamceuticals and metabolites belonging to a multitude of different classes in surface waters and wastewater effluent. The methods will be used in future studies...
Coumarins in horse chestnut flowers: isolation and quantification by UPLC method.
Dudek-Makuch, Marlena; Matławska, Irena
2013-01-01
The coumarins: scopoletin, esculetin and fraxetin were isolated from the flowers of horse chestnut (Aesculus hippocastanum L., Hippocastanaceae) and identified by spectrophotometric methods (UV, 1H, 13C NMR, ESI-MS). Their content, determined using the Ultra Performance Liquid Chromatography (UPLC), was 0.41, 0.13 and 0.05%, respectively.
USDA-ARS?s Scientific Manuscript database
A rapid UPLC method was developed for the simultaneous analysis of five indole alkaloids (harmalol, harmol, harmane, harmaline and harmine) and four flavonoids (orientin, isoorientin, vitexin, and isovitexin) from the aerial parts of Passiflora incarnata L. (Passifloracea), different species of Pass...
USDA-ARS?s Scientific Manuscript database
UPLC with UV detection was used for the quantification of alkaloids from roots of Hydrastis canadensis L. (goldenseal) and dietary supplements claiming to contain goldenseal. The chromatographic run time was less than 6 min. The detection wavelengths used were 290 and 344 nm for '-hydrastine, canadi...
Global metabolic profiling procedures for urine using UPLC-MS.
Want, Elizabeth J; Wilson, Ian D; Gika, Helen; Theodoridis, Georgios; Plumb, Robert S; Shockcor, John; Holmes, Elaine; Nicholson, Jeremy K
2010-06-01
The production of 'global' metabolite profiles involves measuring low molecular-weight metabolites (<1 kDa) in complex biofluids/tissues to study perturbations in response to physiological challenges, toxic insults or disease processes. Information-rich analytical platforms, such as mass spectrometry (MS), are needed. Here we describe the application of ultra-performance liquid chromatography-MS (UPLC-MS) to urinary metabolite profiling, including sample preparation, stability/storage and the selection of chromatographic conditions that balance metabolome coverage, chromatographic resolution and throughput. We discuss quality control and metabolite identification, as well as provide details of multivariate data analysis approaches for analyzing such MS data. Using this protocol, the analysis of a sample set in 96-well plate format, would take ca. 30 h, including 1 h for system setup, 1-2 h for sample preparation, 24 h for UPLC-MS analysis and 1-2 h for initial data processing. The use of UPLC-MS for metabolic profiling in this way is not faster than the conventional HPLC-based methods but, because of improved chromatographic performance, provides superior metabolome coverage.
Tang, Jin-Fa; Li, Wei-Xia; Zhang, Fan; Li, Yu-Hui; Cao, Ying-Jie; Zhao, Ya; Li, Xue-Lin; Ma, Zhi-Jie
2017-01-01
Nowadays, Radix Polygoni Multiflori (RPM, Heshouwu in Chinese) from different geographical origins were used in clinic. In order to characterize the chemical profiles of different geographical origins of RPM samples, ultra-high performance liquid chromatography quadrupole time of flight mass spectrometry (UPLC-QTOF/MS) combined with chemometrics (partial least squared discriminant analysis, PLS‑DA) method was applied in the present study. The chromatography, chemical composition and MS information of RPM samples from 18 geographical origins were acquired and profiled by UPLC-QTOF/MS. The chemical markers contributing the differentiation of RPM samples were observed and characterized by supervised PLS‑DA method of chemometrics. The chemical composition differences of RPM samples derived from 18 different geographical origins were observed. Nine chemical markers were tentatively identified which could be used as specific chemical markers for the differentiation of geographical RPM samples. UPLC-QTOF/MS method coupled with chemometrics analysis has potential to be used for discriminating different geographical TCMs. Results will help to develop strategies for conservation and utilization of RPM samples.
Park, Hee-Won; In, Gyo; Kim, Jeong-Han; Cho, Byung-Goo; Han, Gyeong-Ho; Chang, Il-Moo
2013-01-01
Discriminating between two herbal medicines (Panax ginseng and Panax quinquefolius), with similar chemical and physical properties but different therapeutic effects, is a very serious and difficult problem. Differentiation between two processed ginseng genera is even more difficult because the characteristics of their appearance are very similar. An ultraperformance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-QTOF MS)-based metabolomic technique was applied for the metabolite profiling of 40 processed P. ginseng and processed P. quinquefolius. Currently known biomarkers such as ginsenoside Rf and F11 have been used for the analysis using the UPLC-photodiode array detector. However, this method was not able to fully discriminate between the two processed ginseng genera. Thus, an optimized UPLC-QTOF-based metabolic profiling method was adapted for the analysis and evaluation of two processed ginseng genera. As a result, all known biomarkers were identified by the proposed metabolomics, and additional potential biomarkers were extracted from the huge amounts of global analysis data. Therefore, it is expected that such metabolomics techniques would be widely applied to the ginseng research field. PMID:24558312