Sample records for urea breath testing

  1. Does low dose (13)C-urea breath test maintain a satisfactory accuracy in diagnosing Helicobacter pylori infection?

    PubMed

    Coelho, Luiz Gonzaga Vaz; Silva, Arilto Eleutério da; Coelho, Maria Clara de Freitas; Penna, Francisco Guilherme Cancela e; Ferreira, Rafael Otto Antunes; Santa-Cecilia, Elisa Viana

    2011-01-01

    The standard doses of (13)C-urea in (13)C-urea breath test is 75 mg. To assess the diagnostic accuracy of (13)C-urea breath test containing 25 mg of (13)C-urea comparing with the standard doses of 75 mg in the diagnosis of Helicobacter pylori infection. Two hundred seventy adult patients (96 males, 174 females, median age 41 years) performed the standard (13)C-urea breath test (75 mg (13)C-urea) and repeated the (13)C-urea breath test using only 25 mg of (13)C-urea within a 2 week interval. The test was performed using an infrared isotope analyzer. Patients were considered positive if delta over baseline was >4.0‰ at the gold standard test. One hundred sixty-one (59.6%) patients were H. pylori negative and 109 (40.4%) were positive by the gold standard test. Using receiver operating characteristic analysis we established a cut-off value of 3.4% as the best value of 25 mg (13)C-urea breath test to discriminate positive and negative patients, considering the H. pylori prevalence (95% CI: 23.9-37.3) at our setting. Therefore, we obtained to 25 mg (13)C-urea breath test a diagnostic accuracy of 92.9% (95% CI: 88.1-97.9), sensitivity 83.5% (95% CI: 75.4-89.3), specificity 99.4% (95% CI: 96.6-99.9), positive predictive value 98.3% (95% CI: 92.4-99.4), and negative predictive value 93.0% (95% CI: 88.6-96.1). Low-dose (13)C-urea breath test (25 mg (13)C-urea) does not reach accuracy sufficient to be recommended in clinical setting where a 30% prevalence of H. pylori infection is observed. Further studies should be done to determine the diagnostic accuracy of low doses of (13)C-urea in the urea breath test.

  2. Comparison of Accuracy Between 13C- and 14C-Urea Breath Testing: Is an Indeterminate-Results Category Still Needed?

    PubMed

    Charest, Mathieu; Bélair, Marc-André

    2017-06-01

    Helicobacter pylori infection is the leading cause of peptic ulcer disease. The purpose of this study was, first, to assess the difference in the distribution of negative versus positive results between the older 14 C-urea breath test and the newer 13 C-urea breath test and, second, to determine whether use of an indeterminate-results category is still meaningful and what type of results should trigger repeated testing. Methods: A retrospective survey was performed of all consecutive patients referred to our service for urea breath testing. We analyzed 562 patients who had undergone testing with 14 C-urea and 454 patients who had undergone testing with 13 C-urea. Results: In comparison with the wide distribution of negative 14 C results, negative 13 C results were distributed farther from the cutoff and were grouped more tightly around the mean negative value. Distribution analysis of the negative results for 13 C testing, compared with those for 14 C testing, revealed a statistically significant difference between the two. Within the 13 C group, only 1 patient could have been classified as having indeterminate results using the same indeterminate zone as was used for the 14 C group. This is significantly less frequent than what was found for the 14 C group. Discussion: Borderline-negative results do occur with 13 C-urea breath testing, although less frequently than with 14 C-urea breath testing, and we will be carefully monitoring differences falling between 3.0 and 3.5 %Δ. 13 C-urea breath testing is safe and simple for the patient and, in most cases, provides clearer positive or negative results for the clinician. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  3. sup 14 C-urea breath test for the detection of Helicobacter pylori

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veldhuyzen van Zanten, S.J.; Tytgat, K.M.; Hollingsworth, J.

    1990-04-01

    The high urease activity of Helicobacter pylori can be used to detect this bacterium by noninvasive breath tests. We have developed a {sup 14}C-urea breath test which uses 5 microCi {sup 14}C with 50 mg nonradioactive urea. Breath samples are collected at baseline and every 30 min for 2 h. Our study compared the outcome of the breath test to the results of histology and culture of endoscopically obtained gastric biopsies in 84 patients. The breath test discriminated well between the 50 positive patients and the 34 patients negative for Helicobacter pylori: the calculated sensitivity was 100%, specificity 88%, positivemore » predictive value 93%, and negative predictive value 100%. Treatment with bismuth subsalicylate and/or ampicillin resulted in lower counts of exhaled {sup 14}CO{sub 2} which correlated with histological improvement in gastritis. The {sup 14}C-urea breath test is a better gold standard for the detection of Helicobacter pylori than histology and/or culture.« less

  4. Performance of the 13C-urea breath test for the diagnosis of H. pylori infection using a substrate synthesized in Brazil: A preliminary study.

    PubMed

    Coelho, Luiz Gonzaga; Sant'Ana, Carlos Roberto; Oliveira, Ricardo Brandt de; Cezar, Raíra César E; Araujo, Aline Cordeiro Campos de; Silva, Raisa Cristina Teodoro da; Trindade, Osmar Reni; Coelho, Maria Clara; Ferrioli, Eduardo; Bendassolli, José Albertino

    2018-06-07

    The 13C-urea breath test is the main non-invasive test for the diagnosis of Helicobacter pylori infection. The availability of this test throughout the country is limited, mainly due to the difficulty in obtaining the labeled isotope from abroad. Recently, researchers from the Nuclear Energy Center in Agriculture at the University of São Paulo (CENA/USP) succeeded in synthesizing 13C-enriched urea for Helicobacter pylori diagnosis. The aim of the study was to compare the performance of the 13C-urea breath test using 13C-urea acquired abroad with that of a test using 13C-urea synthesized in Brazil. Sixty-four dyspeptic patients participated in the study (24 men and 40 women). Initially, the patients performed the 13C-urea breath test using the imported substrate (Euriso-Top, France). Seven to fourteen days later, all the patients repeated the test using the Brazilian substrate. The samples from both examinations were processed in an infrared isotope analyzer (IRIS, Wagner Analisen Technik, Germany), and all delta over baseline (DOB) [%] values above four were considered positive results. Twenty-seven patients (42%) exhibited negative results for Helicobacter pylori infection, and thirty-seven patients (58%) exhibited positive results when tested using the foreign substrate (gold standard). There was a 100% concordance regarding the presence or absence of infection when the gold standard results were compared with those obtained using the Brazilian substrate. Similar performance in the diagnosis of Helicobacter pylori infection was demonstrated when using the 13C-urea breath test with the Brazilian 13C-urea substrate and the test with the substrate produced abroad. This validation represents an important step toward increasing the availability of the 13C-urea breath test throughout the country, which will have a positive influence on the management of Helicobacter pylori infection.

  5. Nondispersive infrared spectrometry for 13CO2/12CO2-measurements: a clinically feasible analyzer for stable isotope breath tests in gastroenterology.

    PubMed

    Braden, B; Caspary, W F; Lembcke, B

    1999-06-01

    13C-urea breath tests have become clinical routine for the diagnosis of Helicobacter pylori infection and other isotope breath tests have been invented e.g. for gastric emptying or quantitative liver function testing. Recently, isotope-selective nondispersive infrared spectrometers (NDIRS) have been developed for the analysis of the 13CO2/12CO2-enrichment in breath. In this study, we prospectively tested the validity of a newly developed NDIRS in comparison to isotope ratio mass spectrometry (IRMS). 142 patients with dyspeptic symptoms were tested for Helicobacter pylori infection using the 13C-urea breath test. The isotope ratio analysis of the breath samples was performed in duplicate both using IRMS and NDIRS. The results of the baseline-corrected 13CO2-exhalation values between IRMS and NDIRS were in excellent agreement. The mean difference between both methods was 0.28 +/- 1.93 delta/1000. Evaluating the qualitative urea breath test results in reference to IRMS as the reference the NDIRS had a sensitivity of 97.8% and a specificity of 98.9%. The isotope-selective nondispersive infrared spectroscopy is going to become a reliable, but low-cost and easy-to-operate alternative to expensive isotope ratio mass spectrometry in the analysis of 13C-breath tests.

  6. Performance of acidified 14C-urea capsule breath test during pantoprazole and ranitidine treatment.

    PubMed

    Oztürk, Emel; Yeşilova, Zeki; Ilgan, Seyfettin; Ozgüven, Mehmet; Dağalp, Kemal

    2009-07-01

    Urea breath test (UBT) results could be false negative in patients taking antisecretory drugs. This effect would be prevented by citric acid administration during UBT. We prospectively investigated whether acidified 14C-urea capsule prevents false negative UBT results in patients taking antisecretory drugs and show interference with the duration of medications. Sixty Helicobacter pylori positive patients were included. Pantoprazole (40 mg/day) was given to 27 patients for 28 days and ranitidine (300 mg. o.d.) to 33 patients for 60 days. Urea breath tests were repeated on days 14 and 28 in both groups and on day 60 in the ranitidine group. The baseline mean breath counts of two groups did not show any significant difference. Pantoprazole led to a significant decrease in mean breath counts on day 14 (P < 0.005). Six of 27 and 3 of 25 patients taking pantoprazole developed negative or equivocal UBT results on days 14 and 28, respectively. Two of 32, 2 of 32 and 3 of 21 patients taking ranitidine developed negative or equivocal UBT results on days 14, 28 and 60, respectively. The use of acidified 14C-urea capsule did not prevent false negative UBT results in patients taking pantoprazole and ranitidine, and the duration of medication does not affect the test results.

  7. A novel 13C-urea breath test device for the diagnosis of Helicobacter pylori infection: continuous online measurements allow for faster test results with high accuracy.

    PubMed

    Israeli, Eran; Ilan, Yaron; Meir, Shimon Bar; Buenavida, Claudia; Goldin, Eran

    2003-08-01

    The aim of this study is to determine the accuracy of a novel laptop sized 13C-Urea breath test analyzer that continuously measures expired breath and to use its advantages to decrease testing time. One hundred and eighty-six subjects (mean age of 47.8 years) were tested simultaneously by the BreathID system (Oridion, Israel), and by the traditional IRMS. BreathID continuously measured the expired breath for a ratio of 13CO(2):12CO(2.) This value was expressed as delta over baseline (DOB) and displayed graphically on a screen in real time. One hundred and one subjects were positive and 85 were negative for H. pylori by isotope ratio mass spectrometry (IRMS). The correlation for the BreathID system at 30 minutes was 100% for positive cases and 98% for negative cases. Analysis of the continuous curves generated by the BreathID for all patients permitted definition of different DOB thresholds for a positive or negative result at shorter time intervals. Thus, after 6 minutes a conclusive test result could be obtained for 64% of subjects, and after 10 minutes for 92% of subjects. The 13C-Urea breath test utilizing the technology of molecular correlation spectrometry is an accurate method for determining infection by H. pylori. The advantage of continuous measurements can shorten testing time without compromising accuracy.

  8. Natural 18O and 13C-urea in gastric juice: a new route for non-invasive detection of ulcers.

    PubMed

    Maity, Abhijit; Pal, Mithun; Som, Suman; Maithani, Sanchi; Chaudhuri, Sujit; Pradhan, Manik

    2017-01-01

    The 13 C-urea breath test ( 13 C-UBT), developed a few decades ago, is widely used as a non-invasive diagnostic method to detect only the presence of the gastric pathogen Helicobacter pylori infection; however, the actual disease state, i.e. whether the person harbouring H. pylori has peptic ulcer disease (PUD) or non-ulcerous dyspepsia (NUD), is still poorly understood. Nevertheless, the present 13 C-UBT has numerous limitations, drawbacks and pitfalls owing to the ingestion of 13 C-labelled external urea. Here, we show that H. pylori is able to utilize the natural 13 C and 18 O-urea inherently present in the gastric juice in humans for its urease activity which has never been explored before. In vitro measurements of isotopic fractionations of gastric juice urea provide new insights into the actual state of the infection of PUD or NUD. We also provide evidence of the unusual 13 C and 18 O-isotopic fractionations of breath CO 2 that are distinctively altered in individuals with PUD encompassing both gastric and duodenal ulcers as well as with NUD by the enzymatic activity of H. pylori in the gastric niche without oral administration of any 13 C-enriched external urea. This deepens our understanding of the UBT exploiting the natural 13 C and 18 O-gastric juice urea in the pathogenesis of H. pylori infection, reveals the actual disease state of PUD or NUD and thus offers novel opportunities for a simple, robust, cost-effective and non-toxic global strategy devoid of any 13 C-enriched urea for treating these common diseases by a single breath test. Graphical Abstract Urea breath test without any external urea.

  9. Diagnosis of Peptic Ulcer Disease

    MedlinePlus

    ... urea breath test, you will drink a special liquid that contains urea, a waste product that your body makes as it breaks down protein. If H. pylori are present, the bacteria will change this waste product into carbon dioxide—a harmless gas. Carbon dioxide normally appears in your breath when ...

  10. [Detection of Helicobacter pylori by culture and the 13C-urea breath test using an automated breath 13C analyzer].

    PubMed

    Yamamoto, Y; Kouda, M; Abe, K; Sakurabayashi, S; Sezai, S; Hirano, M; Oka, H

    1995-11-01

    Up to now, the diagnosis of H. pylori infection has been made by the breath test using 13C-urea. In this study, 13C-urea breath samples were tested in 34 patients (peptic ulcer scar 17, chronic gastritis 17 cases) with an automated breath 13C analyzer (ABCA. Europa Scientific, Crewe, UK) and compared with the results of endoscopical diagnosis for H. pylori infection. Endoscopic and 13C-urea breath test (13C-UBT) were performed before eradicative medication. We described a modified protocol for the growth grade of H. pylori colonies in microbiology (H. pylori score), and for the delta 13C area under curve (AUC; permil*hr) obtained from each sample of expired breath. There was a significant correlation between delta 13C-AUC and the delta 13C level of each sample, but the correlation coefficient obtained at 10min (R2 = 0.582) was lower than that obtained at the other four time points (20min; 0.891, 30min; 0.949, 40min; 0.946, 50min; 0.946, 60min; 0.820). The delta 13C-AUC well correlated with H. pylori score (p < 0.01), none of 26 H. pylori positive patients detected by culture was 13C-UBT negative (delta 13C-AUC < 8.2 permil*hr in mean + 2SD of H. pylori negative group). In conclusion, 13C-UBT using ABCA has high sensitivity and specificity, and it provides a non-invasive method for the detection of H. pylori urease activity.

  11. Breath tests sustainability in hospital settings: cost analysis and reimbursement in the Italian National Health System.

    PubMed

    Volpe, M; Scaldaferri, F; Ojetti, V; Poscia, A

    2013-01-01

    The high demand of Breath Tests (BT) in many gastroenterological conditions in time of limited resources for health care systems, generates increased interest in cost analysis from the point of view of the delivery of services to better understand how use the money to generate value. This study aims to measure the cost of C13 Urea and other most utilized breath tests in order to describe key aspects of costs and reimbursements looking at the economic sustainability for the hospital. A hospital based cost-analysis of the main breath tests commonly delivery in an ambulatory setting is performed. Mean salary for professional nurses and gastroenterologists, drugs/preparation used and disposable materials, purchase and depreciation of the instrument and the testing time was used to estimate the cost, while reimbursements are based on the 2013 Italian National Health System ambulatory pricelist. Variables that could influence the model are considered in the sensitivity analyses. The mean cost for C13--Urea, Lactulose and Lactose BT are, respectively, Euros 30,59; 45,20 and 30,29. National reimbursement often doesn't cover the cost of the analysis, especially considering the scenario with lower number of exam. On the contrary, in high performance scenario all the reimbursement could cover the cost, except for the C13 Urea BT that is high influenced by the drugs cost. However, consideration about the difference between Italian Regional Health System ambulatory pricelist are done. Our analysis shows that while national reimbursement rates cover the costs of H2 breath testing, they do not cover sufficiently C13 BT, particularly urea breath test. The real economic strength of these non invasive tests should be considered in the overall organization of inpatient and outpatient clinic, accounting for complete diagnostic pathway for each gastrointestinal disease.

  12. Tests for H. pylori

    MedlinePlus

    Peptic ulcer disease - H. pylori ; PUD - H. pylori ... There are several methods to test for H. pylori infection. Breath Test (Carbon Isotope-urea Breath Test, or UBT) Up to 2 weeks before the test, you need to stop taking ...

  13. Diagnostic accuracy of the 14C-urea breath test in Helicobacter pylori infections: a meta-analysis.

    PubMed

    Zhou, Qiaohui; Li, Ling; Ai, Yaowei; Pan, Zhihong; Guo, Mingwen; Han, Jingbo

    2017-01-01

    To summarize and appraise the available literature regarding the use of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspepsia and to calculate pooled diagnostic accuracy measures. We systematically searched the PubMed, EMBASE, Cochrane Library, Chinese Journals Full-text (CNKI) and CBMDisc databases to identify published data regarding the sensitivity, specificity, and other measures of diagnostic accuracy of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspeptic symptoms. Risk of bias was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies)-2 tool. Statistical analyses were performed using Meta-Disc 1.4 software and STATA. Eighteen studies met the inclusion criteria. Pooled results indicated that the  14 C-urea breath test showed a diagnostic sensitivity of 0.96 (95% CI 0.95 to 0.96) and specificity of 0.93 (95% CI 0.91 to 0.94). The positive like ratio (PLR) was 12.27 (95% CI 8.17 to 18.44), the negative like ratio (NLR) was 0.05 (95% CI 0.04 to 0.07), and the area under the curve was 0.985. The DOR was 294.95 (95% CI 178.37 to 487.70). The 14 C-urea breath test showed sufficient sensitivity and specificity for diagnosing Helicobacter pylori infection, but unexplained heterogeneity after meta-regression and several subgroup analyses remained. The UBT has high accuracy for diagnosing H. pylori infections in adult patients with dyspepsia. However, the reliability of these diagnostic meta-analytic estimates is limited by significant heterogeneity due to unknown factors.

  14. Stability of (13) C-Urea Breath Test Samples Over Time in the Diagnosis of Helicobacter pylori.

    PubMed

    Perets, Tsachi Tsadok; Shporn, Einav; Boltin, Doron; Dickman, Ram; Niv, Yaron

    2016-05-01

    The accuracy and repeatability of breath test in the diagnosis of Helicobacter pylori infection have not been adequately investigated. Although it has been shown that storage for long periods does not affect the analysis results, no data are available on the effect of repetitive testing. In this study, our aim was to evaluate the repeatability of the analyses of breath samples at room temperature. A total of 202 positive breath samples were collected in duplicates, before and after administration of 75 mg (13) C- urea dissolved in 100 ml of orange juice. Breath test results were expressed as delta (13) CO2 . The cut-off value was 3.5 parts per thousand. Each sample was analyzed in a mass spectrometer 7, 14, 21, and 28 days after collection. The accuracy calculation was based on the comparison of the delta (13) CO2 obtained in the three consecutive weeks following the first test run to the delta (13) CO2 obtained in the first test run. Two hundred (99%), 197 (97.52%), and 196 (97%) of the 202 samples tested positive in the second, third, and fourth test runs, respectively. The accuracy of the delta (13) CO2 was 98.6%, 99.2%, and 96.7% in the three consecutive runs, respectively. Short-term storage of 1 month does not affect sample stability or the results of (13) C-urea breath tests in up to three consecutive repeats. © 2015 Wiley Periodicals, Inc.

  15. An optimized 13C-urea breath test for the diagnosis of H pylori infection

    PubMed Central

    Campuzano-Maya, Germán

    2007-01-01

    AIM: To validate an optimized 13C-urea breath test (13C-UBT) protocol for the diagnosis of H pylori infection that is cost-efficient and maintains excellent diagnostic accuracy. METHODS: 70 healthy volunteers were tested with two simplified 13C-UBT protocols, with test meal (Protocol 2) and without test meal (Protocol 1). Breath samples were collected at 10, 20 and 30 min after ingestion of 50 mg 13C-urea dissolved in 10 mL of water, taken as a single swallow, followed by 200 mL of water (pH 6.0) and a circular motion around the waistline to homogenize the urea solution. Performance of both protocols was analyzed at various cut-off values. Results were validated against the European protocol. RESULTS: According to the reference protocol, 65.7% individuals were positive for H pylori infection and 34.3% were negative. There were no significant differences in the ability of both protocols to correctly identify positive and negative H pylori individuals. However, only Protocol 1 with no test meal achieved accuracy, sensitivity, specificity, positive and negative predictive values of 100%. The highest values achieved by Protocol 2 were 98.57%, 97.83%, 100%, 100% and 100%, respectively. CONCLUSION: A 10 min, 50 mg 13C-UBT with no test meal using a cut-off value of 2-2.5 is a highly accurate test for the diagnosis of H pylori infection at a reduced cost. PMID:17907288

  16. Recent analytical approaches to detect exhaled breath ammonia with special reference to renal patients.

    PubMed

    Krishnan, Sanduru Thamarai; Devadhasan, Jasmine Pramila; Kim, Sanghyo

    2017-01-01

    The ammonia odor from the exhaled breath of renal patients is associated with high levels of blood urea nitrogen. Typically, in the liver, ammonia and ammonium ions are converted into urea through the urea cycle. In the case of renal dysfunction, urea is unable to be removed and that causes a buildup of excessive ammonia. As small molecules, ammonia and ammonium ions can be forced into the blood-lung barrier and occur in exhaled breath. Therefore, people with renal failure have an ammonia (fishy) odor in their exhaled breath. Thus, exhaled breath ammonia can be a potential biomarker for monitoring renal diseases during hemodialyis. In this review, we have summarized the source of ammonia in the breath of end-stage renal disease patient, cause of renal disorders, exhaled breath condensate, and breath sampling. Further, various biosensor approaches to detect exhaled ammonia from renal patients and other ammonia systems are also discussed. We conclude with future perspectives, namely colorimetric-based real-time breathing diagnosis of renal failure, which might be useful for prospective studies.

  17. Varying efficacy of Helicobacter pylori eradication regimens: cost effectiveness study using a decision analysis model.

    PubMed

    Duggan, A E; Tolley, K; Hawkey, C J; Logan, R F

    1998-05-30

    To determine how small differences in the efficacy and cost of two antibiotic regimens to eradicate Helicobacter pylori can affect the overall cost effectiveness of H pylori eradication in duodenal ulcer disease. A decision analysis to examine the cost effectiveness of eight H pylori eradication strategies for duodenal ulcer disease with and without 13C-urea breath testing to confirm eradication. Cumulative direct treatment costs per 100 patients with duodenal ulcer disease who were positive for H pylori. In model 1 the strategy of omeprazole, clarithromycin, and metronidazole alone was the most cost effective of the four strategies assessed. The addition of the 13C-urea breath test and a second course of omeprazole, clarithromycin, and metronidazole achieved the highest eradication rate (97%) but was the most expensive (62.63 pounds per patient). The cost of each additional effective eradication was 589.00 pounds (incremental cost per case) when compared with the cost of treating once only with omeprazole, clarithromycin, and metronidazole; equivalent to the cost of a patient receiving ranitidine for duodenal ulcer relapse for more than 15 years. Eradication strategies of omeprazole, amoxycillin, and metronidazole were less cost effective than omeprazole, clarithromycin, and metronidazole alone. In model 2 the addition of the 13C-urea breath test after treatment, and maintenance treatment, increased the cost of all the strategies and reduced the cost advantage of omeprazole, clarithromycin, and metronidazole alone. Small differences in efficacy can influence the comparative cost effectiveness of strategies for eradicating H pylori. Of the strategies tested the most cost effective (omeprazole, clarithromycin, and metronidazole alone) was neither the least expensive (omeprazole, amoxycillin, and metronidazole alone) nor the most effective (omeprazole, clarithromycin, and metronidazole with further treatment for patients found positive for H pylori on 13C-urea breath testing). Cost effectiveness should be an important part of choosing an eradication strategy for H pylori.

  18. Carbon-14 urea breath test: does it work in patients with partial gastric resection?

    PubMed

    Dede, Fuat; Civen, Hüseyin; Dane, Faysal; Aliustaoglu, Mehmet; Turhal, Serdar; Turoglu, Halil Turgut; Inanir, Sabahat

    2015-11-01

    The diagnostic value of Carbon-14 urea breath test (C-14 UBT) in the detection of Helicobacter pylori (H. pylori) infection in non-operated patients has been proved. However, the efficacy of C-14 UBT in patients with partial gastric resection (PGR) has not been evaluated yet. Herein, the results of the C-14 UBT and H. pylori stool antigen test (HpSAT) in this patient group were compared with the endoscopic findings. Multi-breath samples C-14 UBT and HpSAT were performed in all patients on the same day. Histology was used as a gold standard for testing C-14 UBT and HpSAT diagnostic efficacies. 30 patients (mean age: 54.6 ± 11 year) with PGR were included. The sensitivity and specificity of standard C-14 UBT were 29 and 100 %, respectively. When breath samples were collected at 20th min, and >35 CPM was selected as radioactivity threshold, the sensitivity raised to 86 % without any loss of specificity. The specificity and sensitivity of the HpSAT were 71 and 96 %, respectively. The sensitivity of the standard C-14 UBT was very poor for patients with PGR, and results of HpSAT were superior in this population. Certain modifications are needed if C-14 UBT is to be used in PGR patients.

  19. Simplified 13C-urea breath test with a new infrared spectrometer for diagnosis of Helicobacter pylori infection.

    PubMed

    Chen, Tseng-Shing; Chang, Full-Young; Chen, Pang-Chi; Huang, Thomas W; Ou, Jonathan T; Tsai, Ming-Hung; Wu, Ming-Shiang; Lin, Jaw-Town

    2003-11-01

    Infrared spectrometry has correlated excellently with mass spectrometry in detecting the ratio of 13CO(2) to 12CO(2) in breath samples. The present study aimed to evaluate the accuracy of the 13C-urea breath test (13C-UBT) using a new model of infrared analyzer. A total of 600 patients who were undergoing upper endoscopy without receiving eradication therapy were entered into the study. Culture, histology, and rapid urease test on biopsies from the antrum and corpus of the stomach were used for the determination of Helicobacter pylori infection. Breath samples were collected before and 20 min after drinking 100 mg 13C-urea in 100 mL water. The optimal cutoff value was determined by the receiver operating characteristic curve. Of the 586 patients who were eligible for analysis, 369 were positive for H. pylori infection, 185 were negative for H. pylori infection, and 32 were indeterminate. When the appropriate cutoff value was set at 3.5 per thousand, a sensitivity of 97.8%, a specificity of 96.8% and an accuracy of 97.5% were obtained using the 13C-UBT. The accuracy of the 13C-UBT decreased when CO(2) concentration in the breath sample was <2%, as compared with > or = 2% (93.6%vs 97.7%), mainly because of a decrease in specificity (81.8%vs 97.7%). There were 2.7% of patients with Delta13CO(2) values that fell between 3.0-4.5 per thousand, in whom the risk of error was 47%. The 13C-UBT performed with infrared spectrometry is a highly sensitive, specific, and non-invasive method for the detection of H. pylori infection. The immediate availability of the test result and technical simplicity make it particularly effective in routine clinical practice.

  20. Medical Diagnostic Breath Analysis by Cavity Ring Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Guss, Joseph S.; Metsälä, Markus; Halonen, Lauri

    2009-06-01

    Certain medical conditions give rise to the presence of chemicals in the bloodstream. These chemicals - known as biomarkers - may also be present in low concentrations in human breath. Cavity ring down spectroscopy possesses the requisite selectivity and sensitivity to detect such biomarkers in the congested spectrum of a breath sample. The ulcer-causing bacterium, Helicobacter pylori, is a prolific producer of the enzyme urease, which catalyses the breakdown of urea ((NH_2)_2CO) in the stomach as follows: (NH_2)_2CO + H_2O ⟶ CO_2 + 2NH_3 Currently, breath tests seeking altered carbon-isotope ratios in exhaled CO_2 after the ingestion of ^{13}C- or ^{14}C-labeled urea are used to diagnose H. pylori infection. We present recent results from an ongoing collaboration with Tampere Area University Hospital. The study involves 100 patients (both infected and uninfected) and concerns the possible correlation between the bacterial infection and breath ammonia. D. Y. Graham, P. D. Klein, D. J. Evans, Jr, D. G. Evans, L. C. Alpert, A. R. Opekun, T. W. Boutton, Lancet 1(8543), 1174-7 March 1987.

  1. Isotope ratio mass spectrometry (IRMS) versus laser-assisted ratio analyzer (LARA): a comparative study using two doses of.

    PubMed

    Savarino, V; Landi, F; Dulbecco, P; Ricci, C; Tessieri, L; Biagini, R; Gatta, L; Miglioli, M; Celle, G; Vaira, D

    2000-11-01

    This study was carried out to compare the measurements and the diagnostic accuracy of the traditional expensive IRMS and the new economical LARA system using two doses of [13C]urea + two different test meals in patients undergoing upper gastrointestinal endoscopy, both before and after anti-Helicobacter treatment. A total of 354 dyspeptic patients underwent endoscopy with gastric biopsies to diagnose H. pylori infection by CLO-test and histology. No patients had taken antibiotics, bismuth, or antisecretory drugs in the 4 weeks before testing. After overnight fasting, breath samples were collected simultaneously in both plastic and glass tubes at baseline and at 30 and 60 min after urea ingestion. In 237 patients 100 mg [13C]urea + Ensure and in 117 patients 75 mg [13C]urea + citric acid were given. The test was also performed with the two urea dosages and meals in 67 and 64 infected patients, respectively, four weeks after anti-Helicobacter therapy. H. pylori was considered eradicated when both biopsy-based tests were negative. A delta value >5 per thousand was considered positive. Breath samples with insufficient CO2 levels at both 30 and 60 min were excluded from final analysis (N = 37 in pre- and N = 8 in posttreatment). There was excellent agreement between overall delta values of the two machines with both [13C]urea 100 mg + Ensure and [13C]urea 75 mg + citric acid. The 95% CI of the difference against the mean was wider with the former (mean -1.3, +6.3, and -9.4) than with the latter urea dosage and test meal (mean -1.2, +5.2 and -8.1). LARA and IRMS were equally effective (P = NS) in distinguishing infected from uninfected patients before therapy using both doses of [13C]urea and test meals (sensitivity ranged from 95% to 99% and specificity from 95% to 97%). This good performance was maintained in the posttreatment phase (sensitivity ranged from 90% to 100% and specificity from 90% to 97%), without any statistical difference among the various combinations (P = NS). The LARA system is a valid alternative to IRMS in the diagnosis of H. pylori infection. Both machines provide highly reliable results after 30 min, so that the 60 min sample can be avoided. The dose of 75 mg + citric acid suffices to ensure an accurate UBT. The test performed with both devices and [13C]urea dosages is very effective also for posttherapy evaluation of H. pylori status.

  2. Carbon-14 urea breath test for the diagnosis of Campylobacter pylori associated gastritis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, B.J.; Surveyor, I.

    1988-01-01

    Urease in the human gastric mucosa is a marker for infection with Campylobacter pylori (CP), an organism suspected of causing chronic gastritis and peptic ulceration. To detect gastric urease, we examined 32 patients who were being evaluated for possible peptic ulcer disease. Fasting patients were given 10 microCi (370 kBq) of /sup 14/C-labeled urea. Breath samples were collected in hyamine at intervals between 1 and 30 min. The amount of /sup 14/C collected at these times was expressed as: body weight X (% of administered dose of /sup 14/C in sample)/(mmol of CO/sub 2/ collected). The presence of C. pylorimore » colonization was also determined by examination of multiple endoscopic gastric biopsy specimens. On average, patients who were proven to have C. pylori infection exhaled 20 times more labeled CO/sub 2/ than patients who were not infected. The difference between infected patients and C. pylori negative control patients was highly significant at all time points between 2 and 30 min after ingestion of the radionuclide (p less than 0.0001). The noninvasive urea breath is less expensive than endoscopic biopsy of the stomach and more accurate than serology as a means of detecting Campylobacter pylori infection. Because the test detects actual viable CP organisms, it can be used to confirm eradication of the bacterium after antibacterial therapy.« less

  3. The effect of radioactive iodine treatment on 14C urea breath test results in patients with hyperthyroidism.

    PubMed

    Arduc, Ayse; Dogan, Bercem Aycicek; Ozuguz, Ufuk; Tuna, Mazhar Muslim; Gokay, Ferhat; Tutuncu, Yasemin Ates; Isik, Serhat; Aydin, Yusuf; Peksoy, Irfan; Berker, Dilek; Guler, Serdar

    2014-12-01

    Radioactive Iodine therapy (RAIT) plays a major role in the treatment of hyperthyroidism. In addition to the thyroid gland, significant amounts of radioactive iodine are maintained in the stomach. The aim of this study was to determine if RAIT has any effect on Helicobacter pylori infection, based on the C urea breath test (UBT). The study included 85 patients with hyperthyroidism scheduled to undergo RAIT and 69 hyperthyroid subjects in whom methimazole treatment was planned. All subjects had pretreatment-positive UBT results, and the test was repeated on the first and third months after RAIT and methimazole treatment. After a mean RAIT dose of 15 mCi (range, 10-20 mCi), UBT became negative in 13 (15.3%) of 85 patients on the first month and 18 (21.2%) of 85 patients on the third month. All subjects treated with methimazole remained UBT positive on the first and third months of methimazole treatment (100%). Reduction in the number of UBT-positive patients on both the first and the third months after RAIT was statistically significant (P < 0.001). Distribution of hyperthyroidism etiologies and thyroid autoantibody levels in subjects with UBT that became negative and in subjects with UBT that remained positive were similar in the RAIT group (P > 0.05). Urea breath test negativity rates did not differ according to the radioiodine dose. Our findings indirectly showed that RAIT might have an antimicrobial effect on H. pylori. Clinical applications of this beneficial effect of RAIT on H. pylori should be further evaluated.

  4. New optical analyzer for 13C-breath test

    NASA Astrophysics Data System (ADS)

    Harde, Hermann; Dressler, Matthias; Helmrich, Günther; Wolff, Marcus; Groninga, Hinrich

    2008-04-01

    Medical breath tests are well established diagnostic tools, predominantly for gastroenterological inspections, but also for many other examinations. Since the composition and concentration of exhaled volatile gases reflect the physical condition of a patient, a breath analysis allows one to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that is based on photoacoustic spectroscopy and uses a DFB diode laser at 2.744 μm. The concentration ratio of the CO II isotopologues is determined by measuring the absorption on a 13CO II line in comparison to a 12CO II line. In the specially selected spectral range the lines have similar strengths, although the concentrations differ by a factor of 90. Therefore, the signals are well comparable. Due to an excellent signal-noise-ratio isotope variations of less than 1% can be resolved as required for the breath test.

  5. Diagnosis of Helicobacter pylori infection : A short review.

    PubMed

    Tonkic, Ante; Vukovic, Jonatan; Vrebalov Cindro, Pavle; Pesutic Pisac, Valdi; Tonkic, Marija

    2018-06-29

    Helicobacter pylori infections represent an important factor in the pathogenesis of chronic gastritis, peptic ulcer, MALT lymphoma and gastric adenocarcinoma. The recently published Maastricht V/Florence consensus report indicated that the urea breath test using 13 C urea still remains the best non-invasive test to diagnose H. pylori infections with high sensitivity and specificity. Among the stool antigen tests, the ELISA monoclonal antibody test is a rational option. Effective therapy should be based only on susceptibility testing in regions with documented high clarithromycin resistance (>15%). Advanced high-resolution endoscopic technologies enable increased diagnostic accuracy for detection of H. pylori infections.

  6. Helicobacter pylori colonization of the oral cavity: A milestone discovery

    PubMed Central

    Yee, John KC

    2016-01-01

    Over the past several years, the severity of Helicobacter pylori (H. pylori) infections has not significantly diminished. After successful eradication, the annual H. pylori recurrence rate is approximately 13% due to oral H. pylori infection. Established clinical diagnostic techniques do not identify an oral etiologic basis of H. pylori prior to gastric infection. There has been disagreement as to whether oral infection of H. pylori exists or not, with no definite conclusion. In medical practice, negative results with the urea breath test suggest that the stomach infection of H. pylori is cured in these patients. In fact, patients can present negative urea breath test results and yet exhibit H. pylori infection due to oral infection. The present paper provides evidence that H. pylori oral infection is nonetheless present, and the oral cavity represents a secondary site for H. pylori colonization. PMID:26811613

  7. Proof-of-concept study on the suitability of 13C-urea as a marker substance for assessment of in vivo behaviour of oral colon-targeted dosage forms

    PubMed Central

    Schellekens, RCA; Olsder, GG; Langenberg, SMCH; Boer, T; Woerdenbag, HJ; Frijlink, HW; Kosterink, JGW; Stellaard, F

    2009-01-01

    Background and purpose: 13C-urea may be a suitable marker to assess the in vivo fate of colon-targeted dosage forms given by mouth. We postulated that release in the colon (urease-rich segment) of 13C-urea from colon-targeted capsules would lead to fermentation of 13C-urea by bacterial ureases into 13CO2. Subsequent absorption into the blood and circulation would lead to detectable 13C (as 13CO2) in breath. If, however, release of 13C-urea occurred in the small intestine (urease-poor segment), we expected detectable 13C (as 13C-urea) in blood but no breath 13C (as 13CO2). The differential kinetics of 13C-urea could thus potentially describe both release kinetics and indicate the gastrointestinal segment of release. Experimental approach: The in vivo study consisted of three experiments, during which the same group of four volunteers participated. Key results: The kinetic model was internally valid. The appearance of 13C-in breath CO2 (Ffermented) and the appearance of 13C in blood as 13C-urea (Fnot fermented) show a high inverse correlation (Pearson's r=−0.981, P= 0.06). The total recovery of 13C (Ffermented+Fnot fermented) averaged 99%, indicating complete recovery of the administered 13C via breath and blood. 13CO2 exhalation was observed in all subjects. This indicates that 13C-urea was available in urease-rich segments, such as the caecum or colon. Conclusions and implications: In this proof-of-concept study, 13C-urea was able to provide information on both the release kinetics of a colon-targeted oral dosage form and the gastrointestinal segment where it was released. PMID:19732063

  8. Quantification of Helicobacter pylori infection in gastritis and ulcer disease using a simple and rapid carbon-14-urea breath test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debongnie, J.C.; Pauwels, S.; Raat, A.

    1991-06-01

    Gastric urease was studied isotopically in 230 patients with biopsy-proven normal mucosa or chronic gastritis, including 59 patients with ulcer disease. Carbon-14-urea was given in 25 ml of water without substrate carrier or nutrient-dense meal, and breath samples were collected over a 60-min period. The amount of 14CO2 excreted at 10 min was independent of the rate of gastric emptying and was not quantitatively influenced by the buccal urease activity. The 10-min 14CO2 values discriminated well between Helicobacter pylori positive and negative patients (94% sensitivity, 89% specificity) and correlated with the number of organisms assessed by histology. The test wasmore » a good predictor of chronic gastritis (95% sensitivity and 96% specificity), and a quantitative relationship was observed between 14CO2 values and the severity and activity of the gastritis. In H. pylori positive patients, breath 14CO2 was found to be similar in patients with and without ulcer disease, suggesting that the number of bacteria is not a determining factor for the onset of ulceration.« less

  9. Modified Helicobacter test using a new test meal and a 13C-urea breath test in Helicobacter pylori positive and negative dyspepsia patients on proton pump inhibitors.

    PubMed

    Tepeš, Bojan; Malfertheiner, Peter; Labenz, Joachim; Aygen, Sitke

    2017-08-28

    To determine the sensitivity and specificity of the 13 C-urea breath test (UBT) in patients taking proton pump inhibitors (PPIs), using a new test meal Refex. One hundred and fourteen consecutive patients with dyspepsia, 53 Helicobacter pylori ( H. pylori ) positive, 49 H. pylori negative, were included in the study. The patients were then given esomeprazole 40 mg for 29 consecutive days, and the 13 C-UBT with the new test meal was performed the next morning. The sensitivity of the 13 C-UBT with a cut off 2.5‰ was 92.45% (95%CI: 81.79%-97.91%) by per-protocol (PP) analysis and 78.13% (95%CI: 66.03%-87.49%) by intention-to-treat (ITT) analysis. The specificity of the 13 C-UBT test was 96.00% in the ITT population (95%CI: 86.29%-99.51%) and 97.96% in the PP population (95%CI: 89.15%-99.95%). The new test meal based 13 C-UBT is highly accurate in patients on PPIs and can be used in those unable to stop their PPI treatment.

  10. Isotope-labelled urea to test colon drug delivery devices in vivo: principles, calculations and interpretations.

    PubMed

    Maurer, Marina J M; Schellekens, Reinout C A; Wutzke, Klaus D; Stellaard, Frans

    2013-01-01

    This paper describes various methodological aspects that were encountered during the development of a system to monitor the in vivo behaviour of a newly developed colon delivery device that enables oral drug treatment of inflammatory bowel diseases. [(13)C]urea was chosen as the marker substance. Release of [(13)C]urea in the ileocolonic region is proven by the exhalation of (13)CO2 in breath due to bacterial fermentation of [(13)C]urea. The (13)CO2 exhalation kinetics allows the calculation of a lag time as marker for delay of release, a pulse time as marker for the speed of drug release and the fraction of the dose that is fermented. To determine the total bioavailability, also the fraction of the dose absorbed from the intestine must be quantified. Initially, this was done by calculating the time-dependent [(13)C]urea appearance in the body urea pool via measurement of (13)C abundance and concentration of plasma urea. Thereafter, a new methodology was successfully developed to obtain the bioavailability data by measurement of the urinary excretion rate of [(13)C]urea. These techniques required two experimental days, one to test the coated device, another to test the uncoated device to obtain reference values for the situation that 100 % of [(13)C]urea is absorbed. This is hampered by large day-to-day variations in urea metabolism. Finally, a completely non-invasive, one-day test was worked out based on a dual isotope approach applying a simultaneous administration of [(13)C]urea in a coated device and [(15)N2]urea in an uncoated device. All aspects of isotope-related analytical methodologies and required calculation and correction systems are described.

  11. Optoacoustic 13C-breath test analyzer

    NASA Astrophysics Data System (ADS)

    Harde, Hermann; Helmrich, Günther; Wolff, Marcus

    2010-02-01

    The composition and concentration of exhaled volatile gases reflects the physical ability of a patient. Therefore, a breath analysis allows to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that employs a compact and simple set-up based on photoacoustic spectroscopy. It consists of two identical photoacoustic cells containing two breath samples, one taken before and one after capturing an isotope-marked substrate, where the most common isotope 12C is replaced to a large extent by 13C. The analyzer measures simultaneously the relative CO2 isotopologue concentrations in both samples by exciting the molecules on specially selected absorption lines with a semiconductor laser operating at a wavelength of 2.744 μm. For a reliable diagnosis changes of the 13CO2 concentration of 1% in the exhaled breath have to be detected at a concentration level of this isotope in the breath of about 500 ppm.

  12. Isotope-selective sensor for medical diagnostics based on PAS

    NASA Astrophysics Data System (ADS)

    Wolff, M.; Groninga, H. G.; Harde, H.

    2005-06-01

    Development of new optical sensor technologies has a major impact on the progression of diagnostic methods. Of the permanently increasing number of non-invasive 13C-breath tests, the Urea Breath Test for detection of Helicobacter pylori is the most prominent. However, many recent developments go beyond gastroenterological applications. We present a new detection scheme for breath analysis that employs an especially compact and simple set-up based on Photoacoustic Spectroscopy. Using a wavelength-modulated DFB-diode laser and taking advantage of acoustical resonances of the sample cell, we performed very sensitive isotope-selective measurements on CO2. Detection limits for 13CO2 of a few ppm and for the variation of the 13CO2 concentration of approximately 1% were achieved.

  13. [Comparative diagnostic value of Helicobacter pylori infection testing methods].

    PubMed

    Girdalidze, A M; Elisabedashvili, G V; Sharvadze, L G; Dzhorbenadze, T A

    2013-12-01

    In 213 patients with gastric and duodenal pathology, including received surgery, comparative estimation of results of Helicobacter pylori (Hp) infection testing with invasive and noninvasive methods, were performed. Material for invasive endoscopic biopsy test (EBT), including rapid urease test (RUT) for rapid Hp identification by determination of urease activity, smear cytology and histology was extracted on endoscopy or intraoperationally. RUT was carried out with the help of URE-HP test kit. Serological test for Hp antibodies IgG and IgA class was performed by IFA using kit ELISA. 13С urea breath test (UBT) was made by determination of 13/12CO2 in breath samples on infrared spectroscope. Based on 5 different methods of Hp infection testing Hp positivity in 172 (80,8%) and Hp negativity in 41 (19,2%) from 213 examined patients was revealed. 13С-UBT revealed the highest diagnostic value (accuracy-97,5%, sensibility-97,0%, specificity-100%) in Hp infection diagnostics. In treatment efficiency control this parameters of 13С-UBT are also much high (96,7%, 90,0% and 100% respectively). In spite of high sensitivity of serological test (100%), it had comparative low specificity (71,0%) with high probability of false positive results in treated patients (antibodies titer to Hp after eradication retains for a long time). Thought, this test may be successfully used only in primary patients and in epidemiological studies. Among three methods of EBT, Hp infection detection with RUT revealed the best results (accuracy-94,8%, sensibility-95,0%, specificity-100%). Correlation of RUT and UBT results and much higher diagnostic value of UBT, necessitate RUT with histological study of stomach body mucosa to perform in patients over 45 year, with prolonged anamnesis and dangerous symptoms of disease. In Hp positive patients correlation of index DOB‰ of breath test with results of RUT was revealed. This can serve the index DOB‰ of 13С-UBT as a marker of Hp infection rate. The (accuracy, sensibility and specificity of breath test with local made 13С-urea (98,7%, 98,5% and 100% respectively) are the same as those for BT with standard 13С-urea (96,7%, 96,2% and 100% respectively). Above mentioned, 13С-UBT advantages (noninvasiveness, simplicity, rapidity, safety) and high diagnostic value exceeding same of other applied tests, give us opportunity to offer 13С-UBT as screening method of Hp infection diagnosis and a method of choise in control of Hp infection treatment efficiency.

  14. Photoacoustic sensor for medical diagnostics

    NASA Astrophysics Data System (ADS)

    Wolff, Marcus; Groninga, Hinrich G.; Harde, Hermann

    2004-03-01

    The development of new optical sensor technologies has a major impact on the progress of diagnostic methods. Of the permanently increasing number of non-invasive breath tests, the 13C-Urea Breath Test (UBT) for the detection of Helicobacter pylori is the most prominent. However, many recent developments, like the detection of cancer by breath test, go beyond gastroenterological applications. We present a new detection scheme for breath analysis that employs an especially compact and simple set-up. Photoacoustic Spectroscopy (PAS) represents an offset-free technique that allows for short absorption paths and small sample cells. Using a single-frequency diode laser and taking advantage of acoustical resonances of the sample cell, we performed extremely sensitive and selective measurements. The smart data processing method contributes to the extraordinary sensitivity and selectivity as well. Also, the reasonable acquisition cost and low operational cost make this detection scheme attractive for many biomedical applications. The experimental set-up and data processing method, together with exemplary isotope-selective measurements on carbon dioxide, are presented.

  15. No radiation protection reasons for restrictions on 14C urea breath tests in children.

    PubMed

    Gunnarsson, M; Leide-Svegborn, S; Stenström, K; Skog, G; Nilsson, L-E; Hellborg, R; Mattsson, S

    2002-12-01

    Traditional (14)C urea breath tests are normally not used for younger children because the radiation exposure is unknown. High sensitivity accelerator mass spectrometry and an ultra-low amount (440 Bq) of (14)C urea were therefore used both to diagnose Helicobacter pylori (HP) infection in seven children, aged 3-6 years, and to make radiation dose estimates. The activity used was 125 times lower than the amount normally used for older children and 250 times lower than that used for adults. Results were compared with previously reported biokinetic and dosimetric data for adults and older children aged 7-14 years. (14)C activity concentrations in urine and exhaled air per unit administered activity for younger children (3-6 years) correspond well with those for older children (7-14 years). For a child aged 3-6 years who is HP negative, the urinary bladder wall receives the highest absorbed dose, 0.3 mGy MBq(-1). The effective dose is 0.1 mSv MBq(-1) for the 3-year-old child and 0.07 mSv MBq(-1) for the 6-year-old child. For two children, the 10 min and 20 min post-(14)C administration samples of exhaled air showed a significantly higher amount of (14)C activity than for the rest of the children, that is 6% and 19% of administered activity exhaled per hour compared with 0.3-0.9% (mean 0.5%) of administered activity exhaled per hour indicating that these two children that is were HP positive. For a 3-year-old HP positive child, absorbed dose to the urinary bladder wall was 0.3 mGy MBq(-1) and effective dose per unit of administered activity was 0.4 mSv MBq(-1). Using 55 kBq, which is a normal amount for older children when liquid scintillation counters are used for measurement, the effective dose will be approximately 6 micro Sv to a 3-year-old HP negative child and 20 microSv to a HP positive child. Thus there is no reason for restrictions on performing a normal (14)C urea breath test, even on young children.

  16. Measurement of breath ammonia for detection of patients with chronic kidney disease.

    PubMed

    Bevc, Sebastjan; Mohorko, Eva; Kolar, Mitja; Brglez, Polona; Holobar, Andrej; Kniepeiss, Daniela; Podbregar, Matej; Piko, Nejc; Hojs, Nina; Knehtl, Maša; Ekart, Robert; Hojs, Radovan

    In a healthy individual, ammonia is converted to urea in the liver. Urea is then transported through the bloodstream and then excreted into the urine by the kidneys. In patients with chronic kidney disease (CKD), the accumulated urea is degraded by salivary urease into ammonia, which is then excreted by breathing. Breath ammonia can therefore be used for detecting the increased nitrogen-bearing wastes. In our pilot study, an electrochemical sensor was used to measure and analyze breath ammonia in healthy volunteers and patients with CKD. In our study, 8 patients with CKD (stages 4 and 5) and 6 healthy volunteers were enrolled. All participants were nonsmokers and without pulmonary or liver disease. One controlled breath sample was collected from each participant. Immediately after the sample was collected, a gas analyzer was used for measuring breath ammonia in our participants. Mean creatinine value of CKD patients was 455.2 ± 294.1 µmol/L and 62.1 ± 7.5 µmol/L for healthy volunteers. Breath ammonia levels (3.32 ± 2.19 ppm vs. 0.49 ± 0.08 ppm; p = 0.003) and measured electric current (4.33 ± 0.25 mA vs. 4.01 ± 0.01 mA; p = 0.003) were significantly higher in the CKD group. The results of our pilot study show that breath monitoring of ammonia can be a simple, useful, fast, and noninvasive tool for detection of advanced kidney impairment.
.

  17. Cost-effectiveness of the Carbon-13 Urea Breath Test for the Detection of Helicobacter Pylori

    PubMed Central

    Masucci, L; Blackhouse, G; Goeree, R

    2013-01-01

    Objectives This analysis aimed to evaluate the cost-effectiveness of various testing strategies for Helicobacter pylori in patients with uninvestigated dyspepsia and to calculate the budgetary impact of these tests for the province of Ontario. Data Sources Data on the sensitivity and specificity were obtained from the clinical evidence-based analysis. Resource items were obtained from expert opinion, and costs were applied on the basis of published sources as well as expert opinion. Review Methods A decision analytic model was constructed to compare the costs and outcomes (false-positive results, false-negative results, and misdiagnoses avoided) of the carbon-13 (13C) urea breath test (UBT), enzyme-linked immunosorbent assay (ELISA) serology test, and a 2-step strategy of an ELISA serology test and a confirmatory 13C UBT based on the sensitivity and specificity of the tests and prevalence estimates. Results The 2-step strategy is more costly and more effective than the ELISA serology test and results in $210 per misdiagnosis case avoided. The 13C UBT is dominated by the 2-step strategy, i.e., it is more costly and less effective. The budget impact analysis indicates that it will cost $7.9 million more to test a volume of 129,307 patients with the 13C UBT than with ELISA serology, and $4.7 million more to test these patients with the 2-step strategy. Limitations The clinical studies that were pooled varied in the technique used to perform the breath test and in reference standards used to make comparisons with the breath test. However, these parameters were varied in a sensitivity analysis. The economic model was designed to consider intermediate outcomes only (i.e., misdiagnosed cases) and was not a complete model with final patient outcomes (e.g., quality-adjusted life years). Conclusions Results indicate that the 2-step strategy could be economically attractive for the testing of H. pylori. However, testing with the 2-step strategy will cost the Ministry of Health and Long-Term Care $4.7 million more than with the ELISA serology test. PMID:24228083

  18. Effects of end-stage renal disease and dialysis modalities on blood ammonia level

    PubMed Central

    VAZIRI, Nosratola D.; KHAZAELI, Mahyar; NUNES, Ane C. F.; HARLEY, Kevin T.; SAID, Hyder; ALIPOUR, Omeed; LAU, Wei Ling; PAHL, Madeleine V.

    2018-01-01

    Introduction Uremia results in a characteristic breath odor (uremic fetor) which is largely due to its high ammonia content. Earlier studies have shown a strong correlation between breath ammonia and blood urea levels and a 1 0-fold reduction in breath ammonia after hemodialysis in patients with chronic kidney disease. Potential sources of breath ammonia include: (i) local ammonia production from hydrolysis of urea in the oropharyngeal and respiratory tracts by bacterial flora, and (ii) release of circulating blood ammonia by the lungs. While the effects of uremia and hemodialysis on breath ammonia are well known their effects on blood ammonia are unknown and were explored here. Methods Blood samples were obtained from 23 hemodialysis patients (immediately before and after dialysis), 14 peritoneal dialysis patients, and 10 healthy controls. Blood levels of ammonia, creatinine, urea, and electrolytes were measured. Findings No significant difference was found in baseline blood ammonia between hemodialysis, peritoneal dialysis and control groups. Hemodialysis procedure led to a significant reduction in urea concentration (P<0.001) which was paradoxically accompanied by a modest but significant (P<0.05) rise in blood ammonia level in 10 of the 23 patients studied. Change in blood ammonia pre- and post-hemodialysis correlated with change in serum bicarbonate levels (r=0.61, P<0.01). On subgroup analysis of patients who had a rise in blood ammonia levels after dialysis, there was a strong correlation with drop in mean arterial pressure (r=0.88, P<0.01). The nadir intradialytic systolic blood pressure trended lower in the hemodialysis patients who had a rise in blood ammonia compared to the patients who manifested a fall in blood ammonia (124±8vs.136±6mmHg respectively, P=0.27). Discussion Fall in blood urea following hemodialysis in ESRD patients was paradoxically accompanied by a modest rise in blood ammonia levels in 43% of the patients studied, contrasting prior reported effects of hemodialysis on breath ammonia. In this subgroup of patients, changes in blood ammonia during hemodialysis correlated with rise in blood bicarbonate and fall in mean arterial blood pressure. PMID:27804262

  19. Effects of end-stage renal disease and dialysis modalities on blood ammonia level.

    PubMed

    Vaziri, Nosratola D; Khazaeli, Mahyar; Nunes, Ane C F; Harley, Kevin T; Said, Hyder; Alipour, Omeed; Lau, Wei Ling; Pahl, Madeleine V

    2017-07-01

    Uremia results in a characteristic breath odor (uremic fetor) which is largely due to its high ammonia content. Earlier studies have shown a strong correlation between breath ammonia and blood urea levels and a 10-fold reduction in breath ammonia after hemodialysis in patients with chronic kidney disease. Potential sources of breath ammonia include: (i) local ammonia production from hydrolysis of urea in the oropharyngeal and respiratory tracts by bacterial flora, and (ii) release of circulating blood ammonia by the lungs. While the effects of uremia and hemodialysis on breath ammonia are well known their effects on blood ammonia are unknown and were explored here. Blood samples were obtained from 23 hemodialysis patients (immediately before and after dialysis), 14 peritoneal dialysis patients, and 10 healthy controls. Blood levels of ammonia, creatinine, urea, and electrolytes were measured. No significant difference was found in baseline blood ammonia between hemodialysis, peritoneal dialysis and control groups. Hemodialysis procedure led to a significant reduction in urea concentration (P < 0.001) which was paradoxically accompanied by a modest but significant (P < 0.05) rise in blood ammonia level in 10 of the 23 patients studied. Change in blood ammonia pre- and post-hemodialysis correlated with change in serum bicarbonate levels (r = 0.61, P < 0.01). On subgroup analysis of patients who had a rise in blood ammonia levels after dialysis, there was a strong correlation with drop in mean arterial pressure (r = 0.88, P < 0.01). The nadir intradialytic systolic blood pressure trended lower in the hemodialysis patients who had a rise in blood ammonia compared to the patients who manifested a fall in blood ammonia (124 ± 8 vs. 136 ± 6 mmHg respectively, P = 0.27). Fall in blood urea following hemodialysis in ESRD patients was paradoxically accompanied by a modest rise in blood ammonia levels in 43% of the patients studied, contrasting prior reported effects of hemodialysis on breath ammonia. In this subgroup of patients, changes in blood ammonia during hemodialysis correlated with rise in blood bicarbonate and fall in mean arterial blood pressure. © 2016 International Society for Hemodialysis.

  20. Audit of Helicobacter pylori Testing in Microbiology Laboratories in England: To Inform Compliance with NICE Guidance and the Feasibility of Routine Antimicrobial Resistance Surveillance

    PubMed Central

    Allison, Rosalie; Lecky, Donna M.; Bull, Megan; Turner, Kim; Godbole, Gauri

    2016-01-01

    Introduction. The National Institute for Health and Clinical Excellence (NICE) guidance recommends that dyspeptic patients are tested for Helicobacter pylori using a urea breath test, stool antigen test, or serology. Antibiotic resistance in H. pylori is globally increasing, but treatment in England is rarely guided by susceptibility testing or surveillance. Aims. To determine compliance of microbiology laboratories in England with NICE guidance and whether laboratories perform culture and antibiotic susceptibility testing (AST). Methods. In 2015, 170 accredited English microbiology laboratories were surveyed, by email. Results. 121/170 (71%) laboratories responded; 96% provided H. pylori testing (78% on site). 94% provided H. pylori diagnosis using stool antigen; only four provided serology as their noninvasive test; 3/4 of these encouraged urea breath tests in their acute trusts. Only 22/94 (23%) of the laboratories performed H. pylori cultures from gastric biopsies on site; 9/22 performed AST, but the vast majority processed less than one specimen/week. Conclusions. Only five laboratories in England do not comply with NICE guidance; these will need the guidance reinforced. National surveillance needs to be implemented; culture-based AST would need to be centralised. Moving forward, detection of resistance in H. pylori from stool specimens using molecular methods (PCR) needs to be explored. PMID:27829836

  1. Photoacoustic sensor for VOCs: first step towards a lung cancer breath test

    NASA Astrophysics Data System (ADS)

    Wolff, Marcus; Groninga, Hinrich G.; Dressler, Matthias; Harde, Hermann

    2005-08-01

    Development of new optical sensor technologies has a major impact on the progression of diagnostic methods. Specifically, the optical analysis of breath is an extraordinarily promising technique. Spectroscopic sensors for the non-invasive 13C-breath tests (the Urea Breath Test for detection of Helicobacter pylori is most prominent) are meanwhile well established. However, recent research and development go beyond gastroenterological applications. Sensitive and selective detection of certain volatile organic compounds (VOCs) in a patient's breath, could enable the diagnosis of diseases that are very difficult to diagnose with contemporary techniques. For instance, an appropriate VOC biomarker for early-stage bronchial carcinoma (lung cancer) is n-butane (C4H10). We present a new optical detection scheme for VOCs that employs an especially compact and simple set-up based on photoacoustic spectroscopy (PAS). This method makes use of the transformation of absorbed modulated radiation into a sound wave. Employing a wavelength-modulated distributed feedback (DFB) diode laser and taking advantage of acoustical resonances of the sample cell, we performed very sensitive and selective measurements on butane. A detection limit for butane in air in the ppb range was achieved. In subsequent research the sensitivity will be successively improved to match the requirements of the medical application. Upon optimization, our photoacoustic sensor has the potential to enable future breath tests for early-stage lung cancer diagnostics.

  2. Applications of external cavity diode laser-based technique to noninvasive clinical diagnosis using expired breath ammonia analysis: chronic kidney disease, epilepsy

    NASA Astrophysics Data System (ADS)

    Bayrakli, Ismail; Turkmen, Aysenur; Akman, Hatice; Sezer, M. Tugrul; Kutluhan, Suleyman

    2016-08-01

    An external cavity laser (ECL)-based off-axis cavity-enhanced absorption spectroscopy was applied to noninvasive clinical diagnosis using expired breath ammonia analysis: (1) the correlation between breath ammonia levels and blood parameters related to chronic kidney disease (CKD) was investigated and (2) the relationship between breath ammonia levels and blood concentrations of valproic acid (VAP) was studied. The concentrations of breath ammonia in 15 healthy volunteers, 10 epilepsy patients (before and after taking VAP), and 27 patients with different stages of CKD were examined. The range of breath ammonia levels was 120 to 530 ppb for healthy subjects and 710 to 10,400 ppb for patients with CKD. There was a statistically significant positive correlation between breath ammonia concentrations and urea, blood urea nitrogen, creatinine, or estimated glomerular filtration rate in 27 patients. It was demonstrated that taking VAP gave rise to increasing breath ammonia levels. A statistically significant difference was found between the levels of exhaled ammonia (NH3) in healthy subjects and in patients with epilepsy before and after taking VAP. The results suggest that our breath ammonia measurement system has great potential as an easy, noninvasive, real-time, and continuous monitor of the clinical parameters related to epilepsy and CKD.

  3. Excretory nitrogen metabolism and defence against ammonia toxicity in air-breathing fishes.

    PubMed

    Chew, S F; Ip, Y K

    2014-03-01

    With the development of air-breathing capabilities, some fishes can emerge from water, make excursions onto land or even burrow into mud during droughts. Air-breathing fishes have modified gill morphology and morphometry and accessory breathing organs, which would tend to reduce branchial ammonia excretion. As ammonia is toxic, air-breathing fishes, especially amphibious ones, are equipped with various strategies to ameliorate ammonia toxicity during emersion or ammonia exposure. These strategies can be categorized into (1) enhancement of ammonia excretion and reduction of ammonia entry, (2) conversion of ammonia to a less toxic product for accumulation and subsequent excretion, (3) reduction of ammonia production and avoidance of ammonia accumulation and (4) tolerance of ammonia at cellular and tissue levels. Active ammonia excretion, operating in conjunction with lowering of ambient pH and reduction in branchial and cutaneous NH₃ permeability, is theoretically the most effective strategy to maintain low internal ammonia concentrations. NH₃ volatilization involves the alkalization of certain epithelial surfaces and requires mechanisms to prevent NH₃ back flux. Urea synthesis is an energy-intensive process and hence uncommon among air-breathing teleosts. Aestivating African lungfishes detoxify ammonia to urea and the accumulated urea is excreted following arousal. Reduction in ammonia production is achieved in some air-breathing fishes through suppression of amino acid catabolism and proteolysis, or through partial amino acid catabolism leading to alanine formation. Others can slow down ammonia accumulation through increased glutamine synthesis in the liver and muscle. Yet, some others develop high tolerance of ammonia at cellular and tissue levels, including tissues in the brain. In summary, the responses of air-breathing fishes to ameliorate ammonia toxicity are many and varied, determined by the behaviour of the species and the nature of the environment in which it lives. © 2014 The Fisheries Society of the British Isles.

  4. Cut-off optimization for 13C-urea breath test in a community-based trial by mathematic, histology and serology approach.

    PubMed

    Li, Zhe-Xuan; Huang, Lei-Lei; Liu, Cong; Formichella, Luca; Zhang, Yang; Wang, Yu-Mei; Zhang, Lian; Ma, Jun-Ling; Liu, Wei-Dong; Ulm, Kurt; Wang, Jian-Xi; Zhang, Lei; Bajbouj, Monther; Li, Ming; Vieth, Michael; Quante, Michael; Zhou, Tong; Wang, Le-Hua; Suchanek, Stepan; Soutschek, Erwin; Schmid, Roland; Classen, Meinhard; You, Wei-Cheng; Gerhard, Markus; Pan, Kai-Feng

    2017-05-18

    The performance of diagnostic tests in intervention trials of Helicobacter pylori (H.pylori) eradication is crucial, since even minor inaccuracies can have major impact. To determine the cut-off point for 13 C-urea breath test ( 13 C-UBT) and to assess if it can be further optimized by serologic testing, mathematic modeling, histopathology and serologic validation were applied. A finite mixture model (FMM) was developed in 21,857 subjects, and an independent validation by modified Giemsa staining was conducted in 300 selected subjects. H.pylori status was determined using recomLine H.pylori assay in 2,113 subjects with a borderline 13 C-UBT results. The delta over baseline-value (DOB) of 3.8 was an optimal cut-off point by a FMM in modelling dataset, which was further validated as the most appropriate cut-off point by Giemsa staining (sensitivity = 94.53%, specificity = 92.93%). In the borderline population, 1,468 subjects were determined as H.pylori positive by recomLine (69.5%). A significant correlation between the number of positive H.pylori serum responses and DOB value was found (r s  = 0.217, P < 0.001). A mathematical approach such as FMM might be an alternative measure in optimizing the cut-off point for 13 C-UBT in community-based studies, and a second method to determine H.pylori status for subjects with borderline value of 13 C-UBT was necessary and recommended.

  5. Use of a least absolute shrinkage and selection operator (LASSO) model to selected ion flow tube mass spectrometry (SIFT-MS) analysis of exhaled breath to predict the efficacy of dialysis: a pilot study.

    PubMed

    Wang, Maggie Haitian; Chong, Ka Chun; Storer, Malina; Pickering, John W; Endre, Zoltan H; Lau, Steven Yf; Kwok, Chloe; Lai, Maria; Chung, Hau Yin; Ying Zee, Benny Chung

    2016-09-28

    Selected ion flow tube-mass spectrometry (SIFT-MS) provides rapid, non-invasive measurements of a full-mass scan of volatile compounds in exhaled breath. Although various studies have suggested that breath metabolites may be indicators of human disease status, many of these studies have included few breath samples and large numbers of compounds, limiting their power to detect significant metabolites. This study employed a least absolute shrinkage and selective operator (LASSO) approach to SIFT-MS data of breath samples to preliminarily evaluate the ability of exhaled breath findings to monitor the efficacy of dialysis in hemodialysis patients. A process of model building and validation showed that blood creatinine and urea concentrations could be accurately predicted by LASSO-selected masses. Using various precursors, the LASSO models were able to predict creatinine and urea concentrations with high adjusted R-square (>80%) values. The correlation between actual concentrations and concentrations predicted by the LASSO model (using precursor H 3 O + ) was high (Pearson correlation coefficient  =  0.96). Moreover, use of full mass scan data provided a better prediction than compounds from selected ion mode. These findings warrant further investigations in larger patient cohorts. By employing a more powerful statistical approach to predict disease outcomes, breath analysis using SIFT-MS technology could be applicable in future to daily medical diagnoses.

  6. Guar gum does not impair the absorption and utilization of dietary nitrogen but affects early endogenous urea kinetics in humans.

    PubMed

    Mariotti, F; Pueyo, M E; Tomé, D; Benamouzig, R; Mahé, S

    2001-10-01

    Viscous gums enhance viscosity in the upper gastrointestinal lumen, quickly disturbing motility and promoting fluid secretion. We sought to determine whether guar gum could acutely affect the absorption and utilization of dietary nitrogen and whether these luminal effects could also perturb the kinetics of urea. We studied the short-term effect of adding 1% of highly viscous guar gum to a (15)N-labeled protein meal (30 g soy protein isolate in 500 mL water) during the postprandial phase in humans. The effects on bioavailability were studied by using the [(13)C]glycine breath test (to assess gastric emptying) and (15)N enrichment in plasma amino acids (for systemic amino acid bioavailability). The kinetics of dietary and endogenous urea were assessed in plasma and urine. Guar gum modulated the gastric emptying kinetics of the liquid phase of the meal slightly (P < 0.05), but had no significant effect on either the systemic appearance of dietary amino acids or plasma and urinary dietary urea kinetics. Without significantly affecting plasma urea concentrations, guar gum reduced by approximately 40% the urinary excretion of endogenous urea for the first 2-h period after the meal (P < 0.01), although endogenous urinary excretion was similar at later stages. Guar gum did not significantly affect the bioavailability or utilization of dietary protein. We showed an early effect of guar gum on endogenous urea kinetics, which most probably arose from very early, short-term stimulation of the intestinal disposal of endogenous urea, at the expense of its urinary excretion.

  7. A simplified urea breath test for the diagnosis of Helicobacter pylori infection using the LARA System. Laser Assisted Ratio Analyzer.

    PubMed

    Minoli, G; Prada, A; Schuman, R; Murnick, D; Rigas, B

    1998-06-01

    Helicobacter pylori, one of the most prevalent human pathogens, is associated with chronic gastritis, peptic ulcer disease, and possibly gastric cancer and primary gastric lymphoma. The need to treat these patients has necessitated the development of improved methods to diagnose H. pylori infection. We present the preliminary assessment of a 13C-urea breath test (UBT) in which the expired 13CO2 is detected in a rapid, simple, inexpensive way by the LARA (Laser Assisted Ratio Analyzer) System (Alimenterics, Inc., Morris Plains, NJ). Eighty-seven consecutive patients, examined for upper gastrointestinal symptoms, underwent endoscopy. H. pylori infection was established by antral biopsies and a rapid urease test (CLOtest). The UBT was performed between 2 and 24 hours after endoscopy. Of the 84 analyzable patients, 70 were found to be H. pylori-positive either by histology or by CLOtest. All 70 were positive by the LARA UBT, yielding a sensitivity of 100%. Fourteen patients were negative for H. pylori by histology and the CLOtest. Of these, 12 were negative by the LARA UBT and 2 were positive, yielding a specificity of 85.7%; because of the limitations of H. pylori detection by histology or urease assays, however, the specificity of the UBT may have been underestimated. Our study demonstrates the feasibility of a nonradioactive, rapid UBT based on the LARA system and suggests the need for its more detailed evaluation.

  8. Aggravation of Helicobacter pylori stomach infections in stressed military recruits.

    PubMed

    Jia, Keran; An, Liyun; Wang, Fukun; Shi, Lanchun; Ran, Xiangyang; Wang, Xianling; He, Zhanguo; Chen, Jing

    2016-04-01

    To investigate the effect of military stress on immune response and Helicobacter pylori stomach infections. In this prospective, observational study, the Symptom Checklist-90 questionnaire was completed by military recruits before and following a 3-month basic training programme. H. pylori immunoglobulin (Ig)G levels, C(14)-urea breath-test values and levels of cortisol, catecholamine, and certain humoral and cellular immune responses were measured before and after the basic training. For 60 military recruits, somatization, depression and paranoid ideation scores were significantly increased after, compared with before, basic training. Post-training H. pylori IgG detection revealed three additional cases of H. pylori infection. Post-training C(14)-urea breath-test values were significantly higher compared with before training - thus suggesting higher levels of H. pylori colonization in the stomach. Post-training cortisol and catecholamine levels were increased, while serum IgG levels were decreased; complement component (C)3 and C4 levels remained unchanged. Post-training CD4(+) and CD8(+) T-cell percentages and the CD4(+)/CD8(+) ratio were significantly reduced compared with before training. Serum interleukin (IL)-2 levels were lower and IL-10 levels were higher following training and there was a significant decrease in the IL-2/IL-10 ratio. Military stress may reduce humoral and cellular immune responses and may aggravate the severity of H. pylori infection. © The Author(s) 2016.

  9. Aggravation of Helicobacter pylori stomach infections in stressed military recruits

    PubMed Central

    Jia, Keran; An, Liyun; Shi, Lanchun; Ran, Xiangyang; Wang, Xianling; He, Zhanguo; Chen, Jing

    2016-01-01

    Objective To investigate the effect of military stress on immune response and Helicobacter pylori stomach infections. Methods In this prospective, observational study, the Symptom Checklist-90 questionnaire was completed by military recruits before and following a 3-month basic training programme. H. pylori immunoglobulin (Ig)G levels, C14-urea breath-test values and levels of cortisol, catecholamine, and certain humoral and cellular immune responses were measured before and after the basic training. Results For 60 military recruits, somatization, depression and paranoid ideation scores were significantly increased after, compared with before, basic training. Post-training H. pylori IgG detection revealed three additional cases of H. pylori infection. Post-training C14-urea breath-test values were significantly higher compared with before training – thus suggesting higher levels of H. pylori colonization in the stomach. Post-training cortisol and catecholamine levels were increased, while serum IgG levels were decreased; complement component (C)3 and C4 levels remained unchanged. Post-training CD4+ and CD8+ T-cell percentages and the CD4+/CD8+ ratio were significantly reduced compared with before training. Serum interleukin (IL)-2 levels were lower and IL-10 levels were higher following training and there was a significant decrease in the IL-2/IL-10 ratio. Conclusion Military stress may reduce humoral and cellular immune responses and may aggravate the severity of H. pylori infection. PMID:26800706

  10. Value of the 13C-urea breath test for detection of gastric Helicobacter spp. infection in dogs undergoing endoscopic examination.

    PubMed

    Kubota, Sanae; Ohno, Koichi; Tsukamoto, Atsushi; Maeda, Shingo; Murata, Yosuke; Nakashima, Ko; Fukushima, Kenjiro; Uchida, Kazuyuki; Fujino, Yasuhito; Tsujimoto, Hajime

    2013-01-01

    Urea breath test (UBT) using an infrared spectral analyzer is widely used for non-invasive and rapid detection of gastric Helicobacter spp. in human, but not veterinary medicine. The main purposes of this study were to determine the reference range of the UBT in dogs and to evaluate its clinical usefulness. To address the first aim, 6 healthy laboratory beagles were subjected to UBT and upper gastrointestinal endoscopy. Gastric endoscopic biopsy samples from the antrum, corpus and fundus were examined for Helicobacter spp. by polymerase chain reaction (PCR) testing, rapid urease test (RUT), histology and cytology. Amoxicillin, metronidazole and omeprazole were given to infected dogs for 14 days, and dogs that became Helicobacter-negative were used to determine the reference range for UBT. To address the second aim, 32 canine patients underwent UBT before upper gastrointestinal endoscopy, and the sensitivity and specificity of UBT were calculated based on our newly determined reference range using PCR as the gold standard for detection of Helicobacter spp. Initially, all 6 laboratory beagles were infected in all gastric regions and became uninfected after eradication. The mean ± 2 SD UBT value after eradication was 0.6 ± 1.8‰, and the reference range for UBT was determined to be less than 2.5‰. UBT was completed successfully in 27 patients. Using our reference range, UBT displayed 89% (16/18) sensitivity and 89% (8/9) specificity, indicating that UBT was quite useful for the detection of gastric Helicobacter spp. infection in dogs.

  11. Organic Gas Sensor with an Improved Lifetime for Detecting Breath Ammonia in Hemodialysis Patients.

    PubMed

    Chuang, Ming-Yen; Chen, Chang-Chiang; Zan, Hsiao-Wen; Meng, Hsin-Fei; Lu, Chia-Jung

    2017-12-22

    In this work, a TFB (poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-(4,4'-(N-(4-s-butylphenyl)diphenylamine)]) sensor with a cylindrical nanopore structure exhibits a high sensitivity to ammonia in ppb-regime. The lifetime and sensitivity of the TFB sensor were studied and compared to those of P3HT (poly(3-hexylthiophene)), NPB (N,N'-di(1-naphthyl)-N,N'-diphenyl-(1,1'-biphenyl)-4,4'-diamine), and TAPC (4,4'-cyclohexylidenebis[N,N-bis(4-methylphenyl) benzenamine]) sensors with the same cylindrical nanopore structures. The TFB sensor outstands the others in sensitivity and lifetime and it shows a sensing response (current variation ratio) of 13% to 100 ppb ammonia after 64 days of storage in air. A repeated sensing periods testing and a long-term measurement have also been demonstrated for the test of robustness. The performance of the TFB sensor is stable in both tests, which reveals that the TFB sensor can be utilized in our targeting clinical trials. In the last part of this work, we study the change of ammonia concentration in the breath of hemodialysis (HD) patients before and after dialysis. An obvious drop of breath ammonia concentration can be observed after dialysis. The reduction of breath ammonia is also correlated with the reduction of blood urea nitrogen (BUN). A correlation coefficient of 0.82 is achieved. The result implies that TFB sensor may be used as a real-time and low cost breath ammonia sensor for the daily tracking of hemodialysis patients.

  12. Exhaled breath condensate adenosine tracks lung function changes in cystic fibrosis

    PubMed Central

    Olsen, Bonnie M.; Lin, Feng-Chang; Fine, Jason; Boucher, Richard C.

    2013-01-01

    Measurement of exhaled breath condensate (EBC) biomarkers offers a noninvasive means to assess airway disease, but the ability of EBC biomarkers to track longitudinal changes in disease severity remains unproven. EBC was collected from pediatric patients with cystic fibrosis (CF) during regular clinic visits over 1 yr. EBC biomarkers urea, adenosine (Ado), and phenylalanine (Phe) were measured by mass spectrometry, and biomarker ratios were used to control for variable dilution of airway secretions. EBC biomarker ratios were assessed relative to lung function in longitudinal, multivariate models and compared with sputum inflammatory markers and quality of life assessment (CFQ-R). EBC was successfully analyzed from 51 subjects during 184 visits (3.6 ± 0.9 visits per subject). EBC Ado/urea ratio was reproducible in duplicate samples (r = 0.62, P < 0.01, n = 20) and correlated with sputum neutrophil elastase (β = 2.5, P < 0.05). EBC Ado/urea correlated with the percentage predicted of forced expiratory volume in 1 s in longitudinal, multivariate models (β = −2.9, P < 0.01); EBC Ado/Phe performed similarly (β = −2.1, P < 0.05). In contrast, IL-8 and elastase measured in spontaneously expectorated sputum (n = 57 samples from 25 subjects) and the CFQ-R respiratory scale (n = 90 tests from 47 subjects) were not significantly correlated with lung function. EBC was readily collected in a clinic setting from a wide range of subjects. EBC Ado tracked longitudinal changes in lung function in CF, with results similar to or better than established measures. PMID:23355385

  13. The Diagnostic Validity of the 13C-Urea Breath Test in the Gastrectomized Patients: Single Tertiary Center Retrospective Cohort Study

    PubMed Central

    Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho

    2014-01-01

    Background: This study was conducted to evaluate the diagnostic validity of the 13C-urea breath test (13C-UBT) in the remnant stomach after partial gastrectomy for gastric cancer. Methods: The 13C-UBT results after Helicobacter pylori eradication therapy was compared with the results of endoscopic biopsy-based methods in the patients who have received partial gastrectomy for the gastric cancer. Results: Among the gastrectomized patients who showed the positive 13C-UBT results (≥ 2.5‰, n = 47) and negative 13C-UBT results (< 2.5‰, n = 114) after H. pylori eradication, 26 patients (16.1%) and 4 patients (2.5%) were found to show false positive and false negative results based on biopsy-based methods, respectively. The sensitivity, specificity, false positive rate, and false negative rate for the cut-off value of 2.5‰ were 84.0%, 80.9%, 19.1%, and 16.0%, respectively. The positive and negative predictive values were 44.7% and 96.5%, respectively. In the multivariate analysis, two or more H. pylori eradication therapies (odds ratio = 3.248, 95% confidence interval= 1.088–9.695, P = 0.035) was associated with a false positive result of the 13C-UBT. Conclusions: After partial gastrectomy, a discordant result was shown in the positive 13C-UBT results compared to the endoscopic biopsy methods for confirming the H. pylori status after eradication. Additional endoscopic biopsy-based H. pylori tests would be helpful to avoid unnecessary treatment for H. pylori eradication in these cases. PMID:25574466

  14. The Efficacy of Saccharomyces boulardii CNCM I-745 in Addition to Standard Helicobacter pylori Eradication Treatment in Children.

    PubMed

    Bin, Zhang; Ya-Zheng, Xu; Zhao-Hui, Deng; Bo, Chu; Li-Rong, Jiang; Vandenplas, Yvan

    2015-03-01

    This study aims to investigate Saccharomyces boulardii CNCM I-745 during Helicobacter pylori eradication in children. One hundred ninety-four H. pylori positive children were randomized in two groups. Therapy (omeprazole+clarithromycin+amoxicillin or omeprazole+clarithromycin+metronidazole in case of penicillin allergy) was given to both groups during two weeks. In the treatment group (n: 102) S. boulardii was added to the triple therapy, while the control group (n: 92) only received triple therapy. The incidence, onset, duration and severity of diarrhea and compliance to the eradication treatment were compared. A (13)C urea breath test was done 4 weeks after the end of eradication therapy in two groups of 21 patients aged 12 years and older to test the H. pylori eradication rate. In the treatment group, diarrhea occurred in 12 cases (11.76%), starting after 6.25±1.24 days, lasting 3.17±1.08 days, and compliance to eradication treatment was 100%. In the control group, diarrhea occurred in 26 cases (28.26%), starting after 4.05±1.11 days, lasting 4.02±0.87 days, and in six cases eradication treatment was stopped prematurely (p<0.05). The (13)C urea breath test showed successful H. pylori eradication in 71.4% of the patients in the treatment and in 61.9 % in the control group (not significant). S. boulardii has a beneficial effect on the prevention and treatment of diarrhea during H. pylori eradication in children. Although S. boulardii did only slightly increase H. pylori eradication rate, compliance to eradication treatment was improved.

  15. Rabeprazole- versus esomeprazole-based eradication regimens for H. pylori infection.

    PubMed

    Wu, I-Chen; Wu, Deng-Chyang; Hsu, Ping-I; Lu, Chien-Yu; Yu, Fang-Jung; Wang, Tsang-En; Chang, Wen-Hsiung; Chen, Jyh-Jon; Kuo, Fu-Chen; Wu, Jeng-Yih; Wang, Wen-Ming; Bair, Ming-Jong

    2007-12-01

    Different kinds of proton pump inhibitor-based triple therapies could result in different Helicobacter pylori eradication rates. The aims of this study were to compare the efficacy and safety of rabeprazole- and esomeprazole-based triple therapy in primary treatment of H. pylori infection in Taiwan. From June 2005 to March 2007, 420 H. pylori-infected patients were randomly assigned to receive a 7-day eradication therapy with either esomeprazole 40 mg daily (EAC group, n = 209) or rabeprazole 20 mg b.i.d. (RAC group, n = 211) in combination with amoxicillin 1 g b.i.d. and clarithromycin 500 mg b.i.d.. Follow-up endoscopy with biopsy was done 12-16 weeks after completion of eradication therapy. Those who refused endoscopic exams underwent (13)C-urea breath test to assess the treatment response. Intention-to-treat analysis revealed that the eradication rate was 89.4% in the EAC group and 90.5% in RAC groups (p-value = .72). All of the subjects returned for assessment of compliance (100% in EAC group vs. 99.5% in RAC group, p-value = .32) and adverse events (3.83% in EAC group vs. 6.16% in RAC group, p-value = .27). Sixty (28.7%) and 37 (17.6%) patients in EAC and RAC group, respectively, refused endoscopy and underwent a (13)C-urea breath test to determine the treatment effect. In conclusion, rabeprazole- and esomeprazole-based primary therapies for H. pylori infection are comparable in efficacy and safety.

  16. Estimate of production of gaseous nitrogen in the human body based on (15)N analysis of breath N2 after administration of [(15)N2]urea.

    PubMed

    Junghans, Peter

    2013-01-01

    After oral administration of [(15)N2]urea (1.5 mmol, 95 atom% (15)N), we found that breath N2 was significantly (15)N-labelled. The result suggests that molecular nitrogen in breath must be partly produced endogenously. Based on a metabolic model, the endogenous N2 production was estimated to be 0.40±0.25 mmol kg(-1) d(-1) or 2.9±1.8 % of the total (urinary and faecal) N excretion in fasted healthy subjects (n=4). In patients infected with Helicobacter pylori (n=5), the endogenous N2 production was increased to 1.24±0.59 mmol kg(-1) d(-1) or 9.0±4.3 % of the total N excretion compared to the healthy controls (p<0.05). We conclude that N balance and gas exchange measurements may be affected by endogenously produced nitrogen, especially in metabolic situations with elevated nitrosation, for instance in oxidative and nitrosative stress-related diseases such as H. pylori infections.

  17. Prevalence and risk factors of helicobacter pylori in Turkey: a nationally-representative, cross-sectional, screening with the 13C-Urea breath test

    PubMed Central

    2013-01-01

    Background Helicobacter pylori is an important global pathogen infecting approximately 50% of the world’s population. This study was undertaken in order to estimate the prevalence rate of Helicobacter pylori infections among adults living in Turkey and to investigate the associated risk factors. Method This study was a nationally representative cross sectional survey, using weighted multistage stratified cluster sampling. All individuals aged ≥18 years in the selected households were invited to participate in the survey. Ninety two percent (n = 2382) of the households in 55 cities participated; 4622 individuals from these households were tested with the 13C-Urea breath test. Helicobacter pylori prevalence and associated factors were analysed by the t test, chi square and multiple logistic regression with SPSS11.0. Results The weighted overall prevalence was 82.5% (95% CI: 81.0-84.2) and was higher in men. It was lowest in the South which has the major fruit growing areas of the country. The factors included in the final model were sex, age, education, marital status, type of insurance (social security), residential region, alcohol use, smoking, drinking water source. While education was the only significant factor for women, residential region, housing tenure, smoking and alcohol use were significant for men in models by sex. Conclusion In Turkey, Helicobacter pylori prevalence was found to be very high. Individuals who were women, elderly adults, single, had a high educational level, were living in the fruit growing region, had social security from Emekli Sandigi, were drinking bottled water, non smokers and regular alcohol consumers, were under less risk of Helicobacter pylori infection than others. PMID:24359515

  18. Prevalence of the colonization of Helicobacter pylori among students of the school of dentistry, University of Granada, Spain

    PubMed Central

    García-Casas, Violeta; Liébana-Cabanillas, Francisco; Arias-Moliz, María-Teresa

    2016-01-01

    Background The oral cavity is a reservoir for Helicobacter pylori, and occupations that involve close contact with it, like Dentistry, could entail a higher risk of colonization. The aim of this study was to evaluate if the length of stay at the School of Dentistry of the University of Granada could influence colonization by H. pylori, and to furthermore correlate colonization by H. pylori, with the state of oral health and oral hygiene habits. Material and Methods The study groups were: Group 1, 35 students of Odontology in their first year of studies; Group 2, the same 35 students when they were in their fifth academic year; Group 3, 35 students from University study programs unrelated with Health and of the same age as the group 2 students. All underwent H. pylori, colonization determinations by means of the urea breath test (UBT), stool antigen test and a serological test. Also studied were the variables plaque index, gingival index and the number of times teeth were brushed per day. The Student t test was used for comparisons among the three studied groups. The Chi-squared test and Pearson correlation coefficient were used to determine any connection between colonization by H. pylori, and the variables studied. Results Comparisons between groups 1 and 2 and between groups 2 and 3 showed significant differences regarding colonization by H. pylori, plaque index, gingival bleeding index and tooth brushing. A positive correlation was found between being colonized by H. pylori, and having a gingival index higher than 10% and tooth brushing once a day or less, in all the studied groups. Conclusions Colonization by H. pylori, among Dentistry students at the University of Granada decreased over a four-year time period at the University. Factors related with better oral health, such as a lower gingival index and more frequent tooth brushings, would explain these results. Key words:Dental students, Helicobacter pylori, serological test, stool antigen test, urea breath test. PMID:27475692

  19. Determining urea levels in exhaled breath condensate with minimal preparation steps and classic LC-MS.

    PubMed

    Pitiranggon, Masha; Perzanowski, Matthew S; Kinney, Patrick L; Xu, Dongqun; Chillrud, Steven N; Yan, Beizhan

    2014-10-01

    Exhaled breath condensate (EBC) provides a relatively easy, non-invasive method for measuring biomarkers of inflammation and oxidative stress in the airways. However, the levels of these biomarkers in EBC are influenced, not only by their levels in lung lining fluid but also by the volume of water vapor that also condenses during EBC collection. For this reason, the use of a biomarker of dilution has been recommended. Urea has been proposed and utilized as a promising dilution biomarker due to its even distribution throughout the body and relatively low volatility. Current EBC urea analytical methods either are not sensitive enough, necessitating large volumes of EBC, or are labor intensive, requiring a derivatization step or other pretreatment. We report here a straightforward and reliable LC-MS approach that we developed that does not require derivatization or large sample volume (∼36 µL). An Acclaim mixed-mode hydrophilic interaction chromatography column was selected because it can produce good peak symmetry and efficiently separate urea from other polar and nonpolar compounds. To achieve a high recovery rate, a slow and incomplete evaporation method was used followed by a solvent-phase exchange. Among EBC samples collected from 28 children, urea levels were found to be highly variable, with a relative standard deviation of 234%, suggesting high variability in dilution of the lung lining fluid component of EBC. The limit of detection was found to be 0.036 µg/mL. Published by Oxford University Press [2013]. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  20. 13CO2/12CO2 ratio analysis in exhaled air by lead-salt tunable diode lasers for noninvasive diagnostics in gastroenterology

    NASA Astrophysics Data System (ADS)

    Stepanov, Eugene V.; Zyrianov, Pavel V.; Miliaev, Valerii A.; Selivanov, Yurii G.; Chizhevskii, Eugene G.; Os'kina, Svetlana; Ivashkin, Vladimir T.; Nikitina, Elena I.

    1999-07-01

    An analyzer of 13CO2/12CO2 ratio in exhaled air based on lead-salt tunable diode lasers is presented. High accuracy of the carbon isotope ratio detection in exhaled carbon dioxide was achieved with help of very simple optical schematics. It was based on the use of MBE laser diodes operating in pulse mode and on recording the resonance CO2 absorption at 4.2 micrometers . Special fast acquisition electronics and software were applied for spectral data collection and processing. Developed laser system was tested in a clinical train aimed to assessment eradication efficiency in therapy of gastritis associated with Helicobacter pylori infection. Data on the 13C-urea breath test used for P.pylori detection and obtained with tunable diode lasers in the course of the trail was compared with the results of Mass-Spectroscopy analysis and histology observations. The analyzer can be used also for 13CO2/12CO2 ratio detection in exhalation to perform gastroenterology breath test based on using other compounds labeled with stable isotopes.

  1. The Efficacy of Saccharomyces boulardii CNCM I-745 in Addition to Standard Helicobacter pylori Eradication Treatment in Children

    PubMed Central

    Bin, Zhang; Ya-Zheng, Xu; Zhao-Hui, Deng; Bo, Chu; Li-Rong, Jiang

    2015-01-01

    Purpose This study aims to investigate Saccharomyces boulardii CNCM I-745 during Helicobacter pylori eradication in children. Methods One hundred ninety-four H. pylori positive children were randomized in two groups. Therapy (omeprazole+clarithromycin+amoxicillin or omeprazole+clarithromycin+metronidazole in case of penicillin allergy) was given to both groups during two weeks. In the treatment group (n: 102) S. boulardii was added to the triple therapy, while the control group (n: 92) only received triple therapy. The incidence, onset, duration and severity of diarrhea and compliance to the eradication treatment were compared. A 13C urea breath test was done 4 weeks after the end of eradication therapy in two groups of 21 patients aged 12 years and older to test the H. pylori eradication rate. Results In the treatment group, diarrhea occurred in 12 cases (11.76%), starting after 6.25±1.24 days, lasting 3.17±1.08 days, and compliance to eradication treatment was 100%. In the control group, diarrhea occurred in 26 cases (28.26%), starting after 4.05±1.11 days, lasting 4.02±0.87 days, and in six cases eradication treatment was stopped prematurely (p<0.05). The 13C urea breath test showed successful H. pylori eradication in 71.4% of the patients in the treatment and in 61.9 % in the control group (not significant). Conclusion S. boulardii has a beneficial effect on the prevention and treatment of diarrhea during H. pylori eradication in children. Although S. boulardii did only slightly increase H. pylori eradication rate, compliance to eradication treatment was improved. PMID:25866729

  2. Studies regarding the mechanism of false negative urea breath tests with proton pump inhibitors.

    PubMed

    Graham, David Y; Opekun, Antone R; Hammoud, Fadi; Yamaoka, Yoshio; Reddy, Rita; Osato, Michael S; El-Zimaity, Hala M T

    2003-05-01

    The mechanism of false negative urea breath tests (UBTs) results among proton pump inhibitor (PPI) users is unknown. We studied the time course of PPI-associated negative UBT, the relation to Helicobacter pylori density, and whether gastric acidification would prevent false negative UBT results. In the UBT experiment, H. pylori-infected volunteers received omeprazole 20 mg b.i.d. for 13.5 days. UBTs with citric acid were done before, after 6.5 days of PPI, and 1, 2, 4, 7, and 14 days after therapy. In the culture and histology experiment, after a wash-out of >5 months, nine of the original subjects were rechallenged with omeprazole for 6.5 days. Antral and corpus biopsies for histology and culture were done before and 1 day after PPI administration. Thirty subjects (mean age 42 yr) were enrolled. UBTs were significantly reduced on day 6.5 (p = 0.031); 10 subjects (33%) developed transient negative UBTs. The UBT recovered in all but one subject by the fourth day post-PPI and in all subjects by day 14. In the culture and histology experiment, upon PPI rechallenge, three of nine subjects (33%) had negative UBTs. H. pylori density, whether measured by culture or histology, decreased with PPI therapy; antral biopsies became histologically negative in five subjects and corpus biopsies in three subjects. PPI-induced negative UBT results were related to the anti-H. pylori effect of the PPI. Acidification of the stomach did not prevent false negative UBT results. Three days is likely the minimum delay from stopping PPI until one should perform a test for active infection. A delay of 14 days is preferred.

  3. Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults

    PubMed Central

    Spacek, Lisa A; Mudalel, Matthew; Tittel, Frank; Risby, Terence H; Solga, Steven F

    2016-01-01

    Blood ammonia is routinely used in clinical settings to assess systemic ammonia in hepatic encephalopathy and urea cycle disorders. Despite its drawbacks, blood measurement is often used as a comparator in breath studies because it is a standard clinical test. We sought to evaluate sources of measurement error and potential clinical utility of breath ammonia compared to blood ammonia. We measured breath ammonia in real time by quartz enhanced photoacoustic spectrometry and blood ammonia in 10 healthy and 10 cirrhotic participants. Each participant contributed 5 breath samples and blood for ammonia measurement within 1 h. We calculated the coefficient of variation (CV) for 5 breath ammonia values, reported medians of healthy and cirrhotic participants, and used scatterplots to display breath and blood ammonia. For healthy participants, mean age was 22 years (±4), 70% were men, and body mass index (BMI) was 27 (±5). For cirrhotic participants, mean age was 61 years (±8), 60% were men, and BMI was 31 (±7). Median blood ammonia for healthy participants was within normal range, 10 μmol L−1 (interquartile range (IQR), 3–18) versus 46 μmol L−1 (IQR, 23–66) for cirrhotic participants. Median breath ammonia was 379 pmol mL−1 CO2 (IQR, 265–765) for healthy versus 350 pmol mL−1 CO2 (IQR, 180–1013) for cirrhotic participants. CV was 17 ± 6%. There remains an important unmet need in the evaluation of systemic ammonia, and breath measurement continues to demonstrate promise to fulfill this need. Given the many differences between breath and blood ammonia measurement, we examined biological explanations for our findings in healthy and cirrhotic participants. We conclude that based upon these preliminary data breath may offer clinically important information this is not provided by blood ammonia. PMID:26658550

  4. Dual therapy for third-line Helicobacter pylori eradication and urea breath test prediction

    PubMed Central

    Nishizawa, Toshihiro; Suzuki, Hidekazu; Maekawa, Takama; Harada, Naohiko; Toyokawa, Tatsuya; Kuwai, Toshio; Ohara, Masanori; Suzuki, Takahiro; Kawanishi, Masahiro; Noguchi, Kenji; Yoshio, Toshiyuki; Katsushima, Shinji; Tsuruta, Hideo; Masuda, Eiji; Tanaka, Munehiro; Katayama, Shunsuke; Kawamura, Norio; Nishizawa, Yuko; Hibi, Toshifumi; Takahashi, Masahiko

    2012-01-01

    We evaluated the efficacy and tolerability of a dual therapy with rabeprazole and amoxicillin (AMX) as an empiric third-line rescue therapy. In patients with failure of first-line treatment with a proton pump inhibitor (PPI)-AMX-clarithromycin regimen and second-line treatment with the PPI-AMX-metronidazole regimen, a third-line eradication regimen with rabeprazole (10 mg q.i.d.) and AMX (500 mg q.i.d.) was prescribed for 2 wk. Eradication was confirmed by the results of the 13C-urea breath test (UBT) at 12 wk after the therapy. A total of 46 patients were included; however, two were lost to follow-up. The eradication rates as determined by per-protocol and intention-to-treat analyses were 65.9% and 63.0%, respectively. The pretreatment UBT results in the subjects showing eradication failure; those patients showing successful eradication comprised 32.9 ± 28.8 permil and 14.8 ± 12.8 permil, respectively. The pretreatment UBT results in the subjects with eradication failure were significantly higher than those in the patients with successful eradication (P = 0.019). A low pretreatment UBT result (≤ 28.5 permil) predicted the success of the eradication therapy with a positive predictive value of 81.3% and a sensitivity of 89.7%. Adverse effects were reported in 18.2% of the patients, mainly diarrhea and stomatitis. Dual therapy with rabeprazole and AMX appears to serve as a potential empirical third-line strategy for patients with low values on pretreatment UBT. PMID:22690086

  5. Residual gas analyzer mass spectrometry for human breath analysis: a new tool for the non-invasive diagnosis of Helicobacter pylori infection.

    PubMed

    Maity, Abhijit; Banik, Gourab D; Ghosh, Chiranjit; Som, Suman; Chaudhuri, Sujit; Daschakraborty, Sunil B; Ghosh, Shibendu; Ghosh, Barnali; Raychaudhuri, Arup K; Pradhan, Manik

    2014-03-01

    A residual gas analyzer (RGA) coupled with a high vacuum chamber is described for the non-invasive diagnosis of the Helicobacter pylori (H. pylori) infection through ¹³C-urea breath analysis. The present RGA-based mass spectrometry (MS) method is capable of measuring high-precision ¹³CO₂ isotope enrichments in exhaled breath samples from individuals harboring the H. pylori infection. The system exhibited 100% diagnostic sensitivity, and 93% specificity alongside positive and negative predictive values of 95% and 100%, respectively, compared with invasive endoscopy-based biopsy tests. A statistically sound diagnostic cut-off value for the presence of H. pylori was determined to be 3.0‰ using a receiver operating characteristic curve analysis. The diagnostic accuracy and validity of the results are also supported by optical off-axis integrated cavity output spectroscopy measurements. The δ¹³(DOB)C‰ values of both methods correlated well (R² = 0.9973 at 30 min). The RGA-based instrumental setup described here is simple, robust, easy-to-use and more portable and cost-effective compared to all other currently available detection methods, thus making it a new point-of-care medical diagnostic tool for the purpose of large-scale screening of the H. pylori infection in real time. The RGA-MS technique should have broad applicability for ¹³C-breath tests in a wide range of biomedical research and clinical diagnostics for many other diseases and metabolic disorders.

  6. Detection of Helicobacter pylori infection by examination of human breath odor using electronic nose Bloodhound-214ST

    NASA Astrophysics Data System (ADS)

    Shnayder, E. P.; Moshkin, M. P.; Petrovskii, D. V.; Shevela, A. I.; Babko, A. N.; Kulikov, V. G.

    2009-05-01

    Our aim was to examine the possibility of use e-nose Bloodhound-214ST to determine presence or absence of H. pylori infection using exhalation samples of patients. Breath samples were collected twice: at baseline and after oral administration of 500 mg of urea. H. pylori status of patients was confirmed by antral biopsy. Using two approaches for the data analysis we showed the possibility to distinguish H. pylori free and infected patients.

  7. A novel one-step Helicobacter pylori saliva antigen test.

    PubMed

    Yang, Bi-Ling; Yeh, Chun; Kwong, Wei-Gang; Lee, Shou-Dong

    2015-02-01

    A rapid, reliable, and sufficiently accurate test for diagnosing Helicobacter pylori infection is required for screening dyspeptic patients before a referral for endoscopy. The purpose of this article is two-fold: first, to evaluate the accuracy of a one-step H. pylori saliva antigen (HPS) test; and second, to compare noninvasive and invasive H. pylori tests in Taiwanese population. A total of 104 consecutive dyspeptic patients admitted for gastroenterology into the outpatient department underwent a one-step HPS test, rapid urease test, histology, and (13)C-urea breath test (13)C-UBT (proto C-13 urea kit). The accuracy of the HPS test was compared with a gold standard defined by at least two positive H. pylori test results from three H. pylori tests (histology, rapid urease test, and (13)C-UBT). The 104 patients eligible for analysis (mean age: 58 years, range 22-87 years), 21 (20%) were gold standard positive. Among them, the positive of the one-step H. pylori saliva Ag test, rapid urease test, (13)C-UBT, histology were (52; 50%), (17; 16%), (27; 25%) and (22; 21%) respectively. The sensitivity and specificity of the HPS tests, rapid urease test, (13)C-UBTs, and histology were 71.43% and 55.42%, 76.19% and 98.80%, 100% and 92.77%, and 85.71% and 95.18%, respectively, relative to the gold standard. The one-step HPS test exhibited a sensitivity of 71.43%, nearly equivalent to that of the rapid urea test. The one-step HPS test exhibited a high sensitivity and low specificity compared with the other tests, indicating that it is not sufficiently accurate for use in a clinical setting for diagnosing H. pylori infection. However, the test is simple to use (requiring only a saliva sample), inexpensive, and noninvasive in its application, and thus appealing for use in population-based prevalence surveys of the epidemiology of H. pylori infection. Copyright © 2014. Published by Elsevier Taiwan.

  8. Molecular hydrogen in human breath: a new strategy for selectively diagnosing peptic ulcer disease, non-ulcerous dyspepsia and Helicobacter pylori infection.

    PubMed

    Maity, Abhijit; Pal, Mithun; Maithani, Sanchi; Ghosh, Barnali; Chaudhuri, Sujit; Pradhan, Manik

    2016-07-22

    The gastric pathogen Helicobacter pylori utilizes molecular hydrogen (H2) as a respiratory substrate during colonization in the gastric mucosa. However, the link between molecular H2 and the pathogenesis of peptic-ulcer disease (PUD) and non-ulcerous dyspepsia (NUD) by the enzymatic activity of H. pylori still remains mostly unknown. Here we provide evidence that breath H2 excretion profiles are distinctly altered by the enzymatic activity of H. pylori for individuals with NUD and PUD. We subsequently unravelled the potential molecular mechanisms responsible for the alteration of H2 in exhaled breath in association with peptic ulcers, encompassing both gastric and duodenal ulcers, along with NUD. We also established that carbon-isotopic fractionations in the acid-mediated bacterial environment regulated by bacterial urease activity cannot discriminate the actual disease state i.e. whether it is peptic ulcer or NUD. However, our findings illuminate the unusual molecular H2 in breath that can track the precise evolution of PUD and NUD, even after the eradication of H. pylori infection. This deepens our understanding of the pathophysiology of PUD and NUD, reveals non-invasively the actual disease state in real-time and thus offers a novel and robust new-generation strategy for treating peptic-ulcer disease together with non-ulcer related complications even when the existing (13)C-urea breath test ((13)C-UBT) fails to diagnose.

  9. Prevalence of Helicobacter pylori among Alaskans: Factors associated with infection and comparison of urea breath test and anti-Helicobacter pylori IgG antibodies.

    PubMed

    Miernyk, Karen M; Bulkow, Lisa R; Gold, Benjamin D; Bruce, Michael G; Hurlburt, Debby H; Griffin, Patricia M; Swerdlow, David L; Cook, Kim; Hennessy, Thomas W; Parkinson, Alan J

    2018-06-01

    Helicobacter pylori is one of the most common human infections in the world, and studies in Alaska Native people, as well as other Indigenous peoples, have shown a high prevalence of this gastric infection. This study was undertaken to determine the prevalence of H. pylori infection by urea breath test (UBT) and anti- H. pylori IgG among Alaskans living in four regions of the state and to identify factors associated with infection. A convenience sample of persons > 6 months old living in five rural and one urban Alaskan community were recruited from 1996 to 1997. Participants were asked about factors possibly associated with infection. Sera were collected and tested for anti- H. pylori IgG antibodies; a UBT was administered to participants > 5 years old. We recruited 710 people of whom 571 (80%) were Alaska Native and 467 (66%) were from rural communities. Rural residents were more likely to be Alaska Native compared with urban residents (P < .001). Of the 710 people, 699 (98%) had a serum sample analyzed, and 634 (97%) persons > 5 years old had a UBT performed. H. pylori prevalence was 69% by UBT and 68% by anti- H. pylori IgG. Among those with a result for both tests, there was 94% concordance. Factors associated with H. pylori positivity were Alaska Native racial status, age ≥ 20 years, rural region of residence, living in a crowded home, and drinking water that was not piped or delivered. Helicobacter pylori prevalence is high in Alaska, especially in Alaska Native persons and rural residents. Concordance between UBT and serology was also high in this group. Two socioeconomic factors, crowding and drinking water that was not piped or delivered, were found to be associated with H. pylori positivity. © 2018 John Wiley & Sons Ltd.

  10. The Measurement of Ammonia in Human Breath and its Potential in Clinical Diagnostics.

    PubMed

    Brannelly, N T; Hamilton-Shield, J P; Killard, A J

    2016-11-01

    Ammonia is an important component of metabolism and is involved in many physiological processes. During normal physiology, levels of blood ammonia are between 11 and 50 µM. Elevated blood ammonia levels are associated with a variety of pathological conditions such as liver and kidney dysfunction, Reye's syndrome and a variety of inborn errors of metabolism including urea cycle disorders (UCD), organic acidaemias and hyperinsulinism/hyperammonaemia syndrome in which ammonia may reach levels in excess of 1 mM. It is highly neurotoxic and so effective measurement is critical for assessing and monitoring disease severity and treatment. Ammonia is also a potential biomarker in exercise physiology and studies of drug metabolism. Current ammonia testing is based on blood sampling, which is inconvenient and can be subject to significant analytical errors due to the quality of the sample draw, its handling and preparation for analysis. Blood ammonia is in gaseous equilibrium with the lungs. Recent research has demonstrated the potential use of breath ammonia as a non-invasive means of measuring systemic ammonia. This requires measurement of ammonia in real breath samples with associated temperature, humidity and gas characteristics at concentrations between 50 and several thousand parts per billion. This review explores the diagnostic applications of ammonia measurement and the impact that the move from blood to breath analysis could have on how these processes and diseases are studied and managed.

  11. Gastrointestinal Physiology During Head Down Tilt Bedrest in Human Subjects

    NASA Technical Reports Server (NTRS)

    Vaksman, Z.; Guthienz, J.; Putcha, L.

    2008-01-01

    Introduction: Gastrointestinal (GI) motility plays a key role in the physiology and function of the GI tract. It directly affects absorption of medications and nutrients taken by mouth, in addition to indirectly altering GI physiology by way of changes in the microfloral composition and biochemistry of the GI tract. Astronauts have reported nausea, loss of appetite and constipation during space flight all of which indicate a reduction in GI motility and function similar to the one seen in chronic bed rest patients. The purpose of this study is to determine GI motility and bacterial proliferation during -6 degree head down tilt bed rest (HTD). Methods: Healthy male and female subjects between the ages of 25-40 participated in a 60 day HTD study protocol. GI transit time (GITT) was determined using lactulose breath hydrogen test and bacterial overgrowth was measured using glucose breath hydrogen test. H. Pylori colonization was determined using C13-urea breath test (UBIT#). All three tests were conducted on 9 days before HDT, and repeated on HDT days 2, 28, 58, and again on day 7 after HDT. Results: GITT increased during HTD compared to the respective ambulatory control values; GITT was significantly lower on day 7 after HTD. A concomitant increase in bacterial colonization was also noticed during HDT starting after approximately 28 days of HDT. However, H. Pylori proliferation was not recorded during HDT as indicated by UBIT#. Conclusion: GITT significantly decreased during HDT with a concomitant increase in the proliferation of GI bacterial flora but not H. pylori.

  12. The Diagnostic Validity of Citric Acid-Free, High Dose (13)C-Urea Breath Test After Helicobacter pylori Eradication in Korea.

    PubMed

    Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Hwang, Jae Jin; Lee, Hyun Joo; Lee, AeRa; Jeong, Yeon Sang; Oh, Sooyeon; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho

    2015-06-01

    The (13)C-urea breath test ((13)C-UBT) is a noninvasive method for diagnosing Helicobacter pylori (H. pylori) infection. The aims of this study were to evaluate the diagnostic validity of the (13)C-UBT cutoff value and to identify influencing clinical factors responsible for aberrant results. (13)C-UBT (UBiTkit; Otsuka Pharmaceutical, cutoff value: 2.5‰) results in the range 2.0‰ to 10.0‰ after H. pylori eradication therapy were compared with the results of endoscopic biopsy results of the antrum and body. Factors considered to affect test results adversely were analyzed. Among patients with a positive (13)C-UBT result (2.5‰ to 10.0‰, n = 223) or a negative (13)C-UBT result (2.0‰ to < 2.5‰, n = 66) after H. pylori eradication, 73 patients (34.0%) were false positive, and one (1.5%) was false negative as determined by endoscopic biopsy. The sensitivity, specificity, false-positive rate, and false-negative rate for a cutoff value of 2.5‰ were 99.3%, 47.1%, 52.9%, and 0.7%, respectively, and positive and negative predictive values of the (13)C-UBT were 67.3% and 98.5%, respectively. Multivariate analysis showed that a history of two or more previous H. pylori eradication therapies (OR = 2.455, 95%CI = 1.299-4.641) and moderate to severe gastric intestinal metaplasia (OR = 3.359, 95%CI = 1.572-7.178) were associated with a false-positive (13)C-UBT result. The (13)C-UBT cutoff value currently used has poor specificity for confirming H. pylori status after eradication, and this lack of specificity is exacerbated in patients that have undergone multiple prior eradication therapies and in patients with moderate to severe gastric intestinal metaplasia. In addition, the citric-free (13)C-UBT would increase a false-positive (13)C-UBT result. © 2015 John Wiley & Sons Ltd.

  13. On the importance of developing a new generation of breath tests for Helicobacter pylori detection.

    PubMed

    Kushch, Ievgeniia; Korenev, Nikolai; Kamarchuk, Lyudmila; Pospelov, Alexander; Kravchenko, Andrey; Bajenov, Leonid; Kabulov, Mels; Amann, Anton; Kamarchuk, Gennadii

    2015-12-15

    State-of-the-art methods for non-invasive detection of the Helicobacter pylori (H. pylori) infection have been considered. A reported global tendency towards a non-decreasing prevalence of H. pylori worldwide could be co-influenced by the functional limitations of urea breath tests (UBTs), currently preferred for the non-invasive recognition of H. pylori in a clinical setting. Namely, the UBTs can demonstrate false-positive or false-negative results. Within this context, limitations of conventional clinically exploited H. pylori tests have been discussed to justify the existing need for the development of a new generation of breath tests for the detection of H. pylori and the differentiation of pathogenic and non-pathogenic strains of the bacterium. This paper presents the results of a pilot clinical study aimed at evaluating the development and diagnostic potential of a new method based on the detection of the non-urease products of H. pylori vital activity in exhaled gas. The characteristics of breath of adolescents with H. pylori-positive and H. pylori-negative functional dyspepsia, together with a consideration of the cytotoxin-associated gene A (CagA) status of H. pylori-positive subjects, have been determined for the first time using innovative point-contact nanosensor devices based on salts of the organic conductor tetracyanoquinodimethane (TCNQ). The clinical and diagnostic relevance of the response curves of the point-contact sensors was assessed. It was found that the recovery time of the point-contact sensors has a diagnostic value for differentiation of the H. pylori-associated peptic ulcer disease. The diagnostically significant elongation of the recovery time was even more pronounced in patients infected with CagA-positive H. pylori strains compared to the CagA-negative patients. Taking into account the operation of the point-contact sensors in the real-time mode, the obtained results are essential prerequisites for the development of a fast and portable breath test for non-invasive detection of cytotoxic CagA strains of H. pylori infection. The relaxation time of the point-contact nanosensors could be selected as a diagnostic criterion for non-invasive determination of H. pylori-associated destructive lesions of the gastroduodenal area in adolescents, using the point-contact spectroscopic concept of breath analysis. This can subsequently be implemented into a 'test-and-treat' approach for the management of uninvestigated dyspepsia in populations with a high prevalence of H. pylori (according to the Maastricht III and IV Consensus recommendations).

  14. Development of low cost instrumentation for non-invasive detection of Helicobacter pylori

    NASA Astrophysics Data System (ADS)

    Kannath, A.; Rutt, H. N.

    2007-02-01

    A new clinical diagnostic instrument for urea breath test (UBT) based non-invasive detection of Helicobacter Pylori is presented here. Its compact and low cost design makes it an economical and commercial alternative for the more expensive Isotope Ratio Mass Spectrometer (IRMS). The instrument is essentially a two channel non-dispersive IR spectrometer that performs high precision ratio measurements of the two carbon isotopomers ( 12CO II and 13CO II) present in exhaled breath. A balanced absorption system configuration was designed where the two channel path lengths would roughly be in the ratio of their concentrations. Equilibrium between the transmitted channel intensities was maintained by using a novel feedback servo mechanism to adjust the length of the 13C channel cell. Extensive computational simulations were performed to study the effect of various possible interferents and their results were considered in the design of the instrument so as to achieve the desired measurement precision of 1%. Specially designed gas cells and a custom made gas filling rig were also developed. A complete virtual interface for both instrument control and data acquisition was implemented in LABVIEW. Initial tests were used to validate the theory and a basic working device was demonstrated.

  15. Patients with established gastro-esophageal reflux disease might benefit from Helicobacter pylori eradication

    PubMed Central

    Moschos, John M.; Kouklakis, George; Vradelis, Stergios; Zezos, Petros; Pitiakoudis, Michael; Chatzopoulos, Dimitrios; Zavos, Christos; Kountouras, Jannis

    2014-01-01

    Background The aim of this study was to investigate the effect of Helicobacter pylori (H. pylori) eradication in selected H. pylori-positive patients with a primary diagnosis of gastro-esophageal reflux disease (GERD) by using the 3-h postprandial esophageal pH monitoring. Methods We recruited patients with erosive esophagitis at endoscopy and H. pylori infection at histology, successfully cured following eradication therapy; the selected H. pylori-positive patients had weekly reflux symptoms for at least six months and endoscopically established Grade A or B esophagitis. Twenty-nine eligible patients were initially subjected to esophageal manometry and ambulatory 3-h postprandial esophageal pH monitoring. All patients received H. pylori triple eradication therapy accompanied by successful H. pylori eradication. After successful eradication of H. pylori (confirmed by 13C urea breath test), a second manometry and 3-h postprandial esophageal pH monitoring were introduced to assess the results of eradication therapy, after a 3-month post-treatment period. Results All 29 selected H. pylori-positive patients became negative due to successful H. pylori eradication, evaluated by 13C urea breath test after a 4-week post-treatment period. Post-eradication, 62.1% patients showed similar manometric pattern at baseline; 17.2% showed improvement; 17.2% normalization; and 3.4% deterioration of the manometric patterns. The DeMeester symptom scoring in the 3-h postprandial ambulatory esophageal pH monitoring was improved after eradication of H. pylori (median 47.47 vs. 22.00, Wilcoxon’s singed rank; P=0.016). On comparing the pH monitoring studies for each patient at baseline and post-eradication period, 82.8% patients showed improvement and 17.2% deterioration of the DeMeester score. Conclusion By using 3-h postprandial esophageal pH monitoring, this study showed, for the first time, that H. pylori eradication may positively influence GERD symptoms. Large-scale controlled relative studies are warranted to confirm these findings. PMID:25330805

  16. Patients with established gastro-esophageal reflux disease might benefit from Helicobacter pylori eradication.

    PubMed

    Moschos, John M; Kouklakis, George; Vradelis, Stergios; Zezos, Petros; Pitiakoudis, Michael; Chatzopoulos, Dimitrios; Zavos, Christos; Kountouras, Jannis

    2014-01-01

    The aim of this study was to investigate the effect of Helicobacter pylori ( H. pylori ) eradication in selected H. pylori -positive patients with a primary diagnosis of gastro-esophageal reflux disease (GERD) by using the 3-h postprandial esophageal pH monitoring. We recruited patients with erosive esophagitis at endoscopy and H. pylori infection at histology, successfully cured following eradication therapy; the selected H. pylori -positive patients had weekly reflux symptoms for at least six months and endoscopically established Grade A or B esophagitis. Twenty-nine eligible patients were initially subjected to esophageal manometry and ambulatory 3-h postprandial esophageal pH monitoring. All patients received H. pylori triple eradication therapy accompanied by successful H. pylori eradication. After successful eradication of H. pylori (confirmed by 13 C urea breath test), a second manometry and 3-h postprandial esophageal pH monitoring were introduced to assess the results of eradication therapy, after a 3-month post-treatment period. All 29 selected H. pylori -positive patients became negative due to successful H. pylori eradication, evaluated by 13 C urea breath test after a 4-week post-treatment period. Post-eradication, 62.1% patients showed similar manometric pattern at baseline; 17.2% showed improvement; 17.2% normalization; and 3.4% deterioration of the manometric patterns. The DeMeester symptom scoring in the 3-h postprandial ambulatory esophageal pH monitoring was improved after eradication of H. pylori (median 47.47 vs. 22.00, Wilcoxon's singed rank; P=0.016). On comparing the pH monitoring studies for each patient at baseline and post-eradication period, 82.8% patients showed improvement and 17.2% deterioration of the DeMeester score. By using 3-h postprandial esophageal pH monitoring, this study showed, for the first time, that H. pylori eradication may positively influence GERD symptoms. Large-scale controlled relative studies are warranted to confirm these findings.

  17. Diagnosis, Treatment, and Outcome in Patients with Bleeding Peptic Ulcers and Helicobacter pylori Infections

    PubMed Central

    2014-01-01

    Upper gastrointestinal (UGI) bleeding is the most frequently encountered complication of peptic ulcer disease. Helicobacter pylori (Hp) infection and nonsteroidal anti-inflammatory drug (NSAID) administration are two independent risk factors for UGI bleeding. Therefore, testing for and diagnosing Hp infection are essential for every patient with UGI hemorrhage. The presence of the infection is usually underestimated in cases of bleeding peptic ulcers. A rapid urease test (RUT), with or without histology, is usually the first test performed during endoscopy. If the initial diagnostic test is negative, a delayed 13C-urea breath test (UBT) or serology should be performed. Once an infection is diagnosed, antibiotic treatment is advocated. Sufficient evidence supports the concept that Hp infection eradication can heal the ulcer and reduce the likelihood of rebleeding. With increased awareness of the effects of Hp infection, the etiologies of bleeding peptic ulcers have shifted to NSAID use, old age, and disease comorbidity. PMID:25101293

  18. Near-infrared light-responsive nanomaterials in cancer therapeutics.

    PubMed

    Shanmugam, Vijayakumar; Selvakumar, S; Yeh, Chen-Sheng

    2014-09-07

    Noninvasive techniques, such as breath tests (urea breath test), blood pressure measurements using a sphygmomanometer and electrocardiography, were employed by a physician to perform classical diagnosis. The use of state-of-the-art noninvasive therapies at the organ level in modern medicine has gradually become possible. However, cancer treatment demands spatially and temporally controlled noninvasive therapy at the cell level because nonspecific toxicity often causes complicated side effects. To increase survival in cancer patients further, combination therapy and combination drugs are explored which demand high specificity to avoid combined-drug side effects. We believe that high specificity could be obtained by implementing near-infrared (NIR) light-assisted nanoparticles in photothermal therapy, chemotherapy, and photodynamic therapy. To refine this therapy and subsequently achieve high efficiency, novel nanomaterials have been designed and modified either to enhance the uptake and drug delivery to the cancer site, or control treatment to administer therapy efficiently. These modifications and developments have been demonstrated to achieve spatial and temporal control when conducting an in vivo xenograft, because the NIR light penetrated effectively the biological tissue. The nanoplatforms discussed in this review are grouped under the following subheadings: Au nanorods (NRs), Au nanoshells, other Au-related nanomaterials, graphene oxide, upconversion nanoparticles, and other related materials (including materials such as CuS, Fe3O4-related systems, and carbon nanotubes (CNTs)).

  19. [The relationship of halitosis and Helicobacter pylori].

    PubMed

    Chen, Xi; Tao, Dan-ying; Li, Qing; Feng, Xi-ping

    2007-06-01

    The aim of the study was to investigate the relationship between halitosis and Helicobacter pylori infection in stomach. Fifty subjects without periodontal diseases and systematic disease (exclude gastrointestinal diseases) were included. Infection of H.pylori was diagnosed by biopsy and (14)C-urea breath test. SPSS11.5 software package was used to analyze the data. All the subjects were periodontal healthy according to the periodontal index. The prevalence of H.pylori infection in halitosis subjects was significantly higher than that in the normal subjects (57.1% VS 18.2%, P<0.01). Logistic regression analysis showed that H.pylori was the only significant variable in the equation(P<0.05). H.pylori in stomach may be involved in the presence of halitosis in periodontal healthy subjects.

  20. 21 CFR 862.1770 - Urea nitrogen test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Urea nitrogen test system. 862.1770 Section 862....1770 Urea nitrogen test system. (a) Identification. A urea nitrogen test system is a device intended to measure urea nitrogen (an end-product of nitrogen metabolism) in whole blood, serum, plasma, and urine...

  1. 21 CFR 862.1770 - Urea nitrogen test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urea nitrogen test system. 862.1770 Section 862....1770 Urea nitrogen test system. (a) Identification. A urea nitrogen test system is a device intended to measure urea nitrogen (an end-product of nitrogen metabolism) in whole blood, serum, plasma, and urine...

  2. 21 CFR 862.1770 - Urea nitrogen test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urea nitrogen test system. 862.1770 Section 862....1770 Urea nitrogen test system. (a) Identification. A urea nitrogen test system is a device intended to measure urea nitrogen (an end-product of nitrogen metabolism) in whole blood, serum, plasma, and urine...

  3. 21 CFR 862.1770 - Urea nitrogen test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Urea nitrogen test system. 862.1770 Section 862....1770 Urea nitrogen test system. (a) Identification. A urea nitrogen test system is a device intended to measure urea nitrogen (an end-product of nitrogen metabolism) in whole blood, serum, plasma, and urine...

  4. 21 CFR 862.1770 - Urea nitrogen test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urea nitrogen test system. 862.1770 Section 862....1770 Urea nitrogen test system. (a) Identification. A urea nitrogen test system is a device intended to measure urea nitrogen (an end-product of nitrogen metabolism) in whole blood, serum, plasma, and urine...

  5. Clustering of Helicobacter pylori infection in couples: differences between high- and low-prevalence population groups.

    PubMed

    Brenner, Hermann; Weyermann, Maria; Rothenbacher, Dietrich

    2006-07-01

    Several mostly small-scale studies reported clustering of Helicobacter pylori infections as a possible indicator of conjugal transmission, but results have been inconsistent. We assessed clustering of H pylori infections in a large community-based study from Germany that included both high-prevalence and low-prevalence population subgroups. Current H pylori infection was determined among 670 couples by means of carbon-13-urea breath test ((13)C-UBT) breath test and a monoclonal antigen immunoassay for H pylori in stool. Prevalences of infection among women were 34.9% (51 of 146 women) if the partner was infected and 14.5% (76 of 524 women) if the partner was not infected. Stratification by nationality showed a strong association of infection for partners with other than German nationality (adjusted odds ratio [OR], 6.05; 95% confidence interval [CI], 1.31-17.96), for whom prevalence of infection was greater than 50%, whereas no association was seen for German partners born in Germany (OR, 1.10; 95% CI, 0.47-2.61), for whom infection prevalence was approximately 10% (p for interaction = 0.048). Conjugal transmission of infection caused by H pylori is unlikely to be of relevance in low-prevalence population groups. Our results are consistent with the hypothesis of a potential role of conjugal transmission of H pylori infection in high-prevalence population groups.

  6. Diagnosis of Helicobacter pylori infection: Current options and developments

    PubMed Central

    Wang, Yao-Kuang; Kuo, Fu-Chen; Liu, Chung-Jung; Wu, Meng-Chieh; Shih, Hsiang-Yao; Wang, Sophie SW; Wu, Jeng-Yih; Kuo, Chao-Hung; Huang, Yao-Kang; Wu, Deng-Chyang

    2015-01-01

    Accurate diagnosis of Helicobacter pylori (H. pylori) infection is a crucial part in the effective management of many gastroduodenal diseases. Several invasive and non-invasive diagnostic tests are available for the detection of H. pylori and each test has its usefulness and limitations in different clinical situations. Although none can be considered as a single gold standard in clinical practice, several techniques have been developed to give the more reliable results. Invasive tests are performed via endoscopic biopsy specimens and these tests include histology, culture, rapid urease test as well as molecular methods. Developments of endoscopic equipment also contribute to the real-time diagnosis of H. pylori during endoscopy. Urea breathing test and stool antigen test are most widely used non-invasive tests, whereas serology is useful in screening and epidemiological studies. Molecular methods have been used in variable specimens other than gastric mucosa. More than detection of H. pylori infection, several tests are introduced into the evaluation of virulence factors and antibiotic sensitivity of H. pylori, as well as screening precancerous lesions and gastric cancer. The aim of this article is to review the current options and novel developments of diagnostic tests and their applications in different clinical conditions or for specific purposes. PMID:26523098

  7. Limiting the testing of urea: Urea along with every plasma creatinine test?

    PubMed

    Zhang, Gao-Ming; Guo, Xu-Xiao; Zhang, Guo-Ming

    2017-09-01

    We found that it is not necessary to simultaneously detect both creatinine (CREA) and urea until the concentration of CREA is lower than the certain level. To reduce urea testing, we suggest measuring urea only when CREA or estimated glomerular filtration rate (eGFR) exceeds a predetermined limit. CREA and urea data were analyzed consisting of almost all of people age above 65 years old check-up (n=95441) in Shuyang countryside, and inpatients (n=101631), outpatients (n=18474) and Routine Health Check-up (n=20509) in Shuyang People's Hospital. The proportions of elevated urea were derived. The data used in this study was generated from people more than 13 years old in both outpatients and inpatients. When the limits for initiating urea testing were used at 85 μmol/L CREA and 120 mL/min/1.73 m 2 eGFR, the percentage of unnecessary urea test are 94.5% and 64.7% (elderly health check-up), 67.9% and 84.5% (outpatients), 88.5% and 73.2% (inpatients), 92.2% and 81.7% (routine health check-up). The missing rate of urea are 1%, 2.5%, 4.6% and 9.2%, 0.1%, 0.4%, 0.9% and 1.8%, 0.4%, 0.8%, 1.4%, and 2.5%, 0.05%, 0.1%, 1.1%, and 0.8% of ureas exceeding 9.28 mmol/L and 8.3 mmol/L in above each group, respectively. If the CREA≤85 μmol/L or eGFR≥90 mL/min/1.73 m 2 , there is 97.5% urea <10.1 mmol/L, the proportion of elevated urea missed is 2.5%. We suggest that the initiating urea testing should be based on the upper limit of Reference Intervals serum CREA of females or a 120 mL/min/1.73 m 2 eGFR limit. Conservatively, the urea testing would be reduced by 65% at least. © 2017 Wiley Periodicals, Inc.

  8. High efficacy of ranitidine bismuth citrate, amoxicillin, clarithromycin and metronidazole twice daily for only five days in Helicobacter pylori Eradication.

    PubMed

    Gisbert, J P; Marcos, S; Gisbert, J L; Pajares, J M

    2001-06-01

    The combination of a proton pump inhibitor (PPI) or ranitidine-bismuth-citrate (Rbc) and two antibiotics for 7-10 days are, at present, the preferred treatments in Helicobacter pylori eradication. However, therapies for fewer than 7 days have been scarcely evaluated and it is unknown whether the length of treatment can be shortened, without a lost of efficacy, if three instead of two antibiotics are used. The aim of our study was to evaluate the efficacy of Rbc plus three antibiotics for only 5 days in H. pylori eradication. We prospectively studied 80 patients (34% duodenal ulcer, 66% functional dyspepsia) infected by H. pylori. At endoscopy, biopsies were obtained for histological study and rapid urease test, and a 13C-urea breath test was carried out. Urea breath test was repeated 4 weeks after completing eradication treatment with Rbc [400 mg twice a day (bid)], amoxicillin (1 g bid), clarithromycin (500 mg bid) and metronidazole (500 mg bid). All drugs were administered together after breakfast and dinner for 5 days only, and no treatment was administered thereafter. Compliance with therapy was determined from the interrogatory and the recovery of empty envelopes of medications. In 79 out of the 80 patients, H. pylori eradication success or failure was assessed after therapy (one patient was lost from follow-up). All but one of these 79 patients took all the medications (one patient stopped treatment on the day 3 due to nausea/vomiting). Per protocol eradication was achieved in 72/78 (92%; 95% CI, 84-96%) and in 72/80 (90%; 81-95%) by intention-to-treat. Therapy was more effective in patients with duodenal ulcer than in those with functional dyspepsia [100% (87-100%) vs. 85% (73-92%) by intention-to-treat; p <.05]. Adverse effects were described in ten patients (12%), and included the perception of a metallic taste (eight patients), nausea/vomiting (two patients, one of them abandoned the treatment due to this), and diarrhea (two patients). The combination of Rbc, amoxicillin, clarithromycin and metronidazole for only 5 days represents a promising therapy for H. pylori infection, due to its high efficacy, simple posology, low cost and excellent tolerance.

  9. Point-of-care Helicobacter pylori urine antibody detection in a multi-ethnic adult population in the United States.

    PubMed

    Opekun, Antone R; Luu, Phong; Gotschall, Ann B; Abdalla, Nageeb; Torres, Elizabeth; Rudd, Summer B; Graham, David Y; Nurgalieva, Zhannat Z; Tsuchiya, Kyoko

    2006-07-01

    A need exists for accurate point-of-care tests for diagnosis of Helicobacter pylori (H. pylori) infection to evaluate a rapid urine-H. pylori antibody test device for detection of H. pylori infection in a point-of-care setting in the United States. A multi-center study in a multi-ethnic population compared the RAPIRUN urine antibody test with the (13)C-urea breath test (C-UBT) and a traditional serologic test, the high-molecular-weight cell-associated protein enzyme immunoassay (HM-CAP EIA). The primary comparator was with "definite positive" and "definite negative" patients defined as a concordance of combined results of the UBT and the HM-CAP IgG EIA. Overall, 188 eligible patients were enrolled (61 men, age range: 18-73 years, including 84 Hispanics, 73 Asian-Pacific Americans, 22 Black African-Americans, 6 non-Hispanic Caucasians, and 3 of "other" ethnicity). Compared with "definite positive" and "definite negative" results, the sensitivity and specificity of the urine antibody test were 0.9 and 1.0, respectively. The urine antibody test proved suitable for point-of-care rapid diagnosis of anti-H. pylori antibodies indicative of active or past H. pylori infection.

  10. Outcome of breath tests in adult patients with suspected small intestinal bacterial overgrowth

    PubMed Central

    Mattsson, Johanna; Minaya, Maria Teresa; Monegro, Milka; Lebwohl, Benjamin; Lewis, Suzanne K.; Green, Peter HR; Stenberg, Reidun

    2017-01-01

    Aim: The aim was to investigate breath test outcomes in patients with suspected SIBO and indicative symptoms of SIBO, diagnosed by breath testing. Background: Breath testing is used to detect small intestinal bacterial overgrowth (SIBO) by measuring hydrogen and methane produced by intestinal bacteria. Methods: This retrospective cross sectional study included 311 patients with gastrointestinal symptoms who underwent the breath test for evaluation of SIBO at Celiac Disease Center at Columbia University, New York, in 2014-2015. The patients were divided into two groups based on the physician’s choice: lactulose breath test group (72%) and glucose breath test group (28%). Among them, 38% had a history of celiac disease or non-celiac gluten sensitivity. Results: In total, 46% had a positive breath test: 18% were positive for methane, 24 % positive for hydrogen and 4% positive for both gases (p=0.014). Also, 50% had a positive lactulose breath result and 37% had a positive glucose breath result (p=0.036). The most common symptom for performing the breath test was bloating and the only clinical symptom that significantly showed a positive glucose breath test was increased gas (p=0.028). Conclusion: Lactulose breath test was more often positive than glucose breath test. Positivity for hydrogen was more common than methane. Bloating was the most frequently perceived symptom of the patients undergoing the breath test but the only statistically significant clinical symptom for a positive glucose breath test was increased gas. Furthermore, the results showed that there was no significant association between positive breath test result and gender, age, non-celiac gluten sensitivity or celiac disease. PMID:29118931

  11. Elevated Airway Purines in COPD

    PubMed Central

    Lazaar, Aili L.; Bordonali, Elena; Qaqish, Bahjat; Boucher, Richard C.

    2011-01-01

    Background: Adenosine and related purines have established roles in inflammation, and elevated airway concentrations are predicted in patients with COPD. However, accurate airway surface purine measurements can be confounded by stimulation of purine release during collection of typical respiratory samples. Methods: Airway samples were collected noninvasively as exhaled breath condensate (EBC) from 36 healthy nonsmokers (NS group), 28 healthy smokers (S group), and 89 subjects with COPD (29 with GOLD [Global Initiative for Chronic Obstructive Lung Disease] stage II, 29 with GOLD stage III, and 31 with GOLD stage IV) and analyzed with mass spectrometry for adenosine, adenosine monophosphate (AMP), and phenylalanine, plus urea as a dilution marker. Variable dilution of airway secretions in EBC was controlled using ratios to urea, and airway surface concentrations were calculated using EBC to serum urea-based dilution factors. Results: EBC adenosine to urea ratios were similar in NS (0.20 ± 0.21) and S (0.22 ± 0.20) groups but elevated in those with COPD (0.32 ± 0.30, P < .01 vs NS). Adenosine to urea ratios were highest in the most severely affected cohort (GOLD IV, 0.35 ± 0.34, P < .01 vs NS) and negatively correlated with FEV1 (r = −0.27, P < .01). Elevated AMP to urea ratios were also observed in the COPD group (0.58 ± 0.97 COPD, 0.29 ± 0.35 NS, P < .02), but phenylalanine to urea ratios were similar in all groups. Airway surface adenosine concentrations calculated in a subset of subjects were 3.2 ± 2.7 μM in those with COPD (n = 28) relative to 1.7 ± 1.5 μM in the NS group (n = 16, P < .05). Conclusions: Airway purines are present on airway surfaces at physiologically significant concentrations, are elevated in COPD, and correlate with markers of COPD severity. Purinergic signaling pathways are potential therapeutic targets in COPD, and EBC purines are potential noninvasive biomarkers. PMID:21454402

  12. Anti-Helicobacter pylori activities of FEMY-R7 composed of fucoidan and evening primrose extract in mice and humans

    PubMed Central

    Kim, Tae-Su; Choi, Ehn-Kyoung; Kim, Jihyun; Shin, Kyungha; Lee, Sung-Pyo; Choi, Youngjin; Jeon, Joseph H.

    2014-01-01

    Helicobacter pylori-eliminating effects of FEMY-R7, composed of fucoidan and evening primrose extract, were investigated in mice and humans. Male C57BL/6 mice were infected with the bacteria by intragastric inoculation (1×109 CFU/mouse) 3 times at 2-day intervals, and simultaneously, orally treated twice a day with 10 or 100 mg/kg FEMY-R7 for 2 weeks. In Campylobcter-like organism-detection test, FEMY-R7 markedly reduced the urease-positive reactivity. In a clinical sudy, human subjects, confirmed to be infected with Helicobacter pylori, were orally administered twice a day with a capsule containing 150 mg FEMY-R7 for 8 weeks. FEMY-R7 significantly decreased both the Delta over baseline-value in urea breath test and the serum pepsinogens I and II levels. The results indicate that FEMY-R7 not only eliminates H. pylori from gastric mucosa of animals and humans, but also improves gastric function. PMID:25324874

  13. Ammonia as a respiratory gas in water and air-breathing fishes.

    PubMed

    Randall, David J; Ip, Yuen K

    2006-11-01

    Ammonia is produced in the liver and excreted as NH(3) by diffusion across the gills. Elevated ammonia results in an increase in gill ventilation, perhaps via stimulation of gill oxygen chemo-receptors. Acidification of the water around the fish by carbon dioxide and acid excretion enhances ammonia excretion and constitutes "environmental ammonia detoxification". Fish have difficulties in excreting ammonia in alkaline water or high concentrations of environmental ammonia, or when out of water. The mudskipper, Periphthalmodon schlosseri, is capable of active NH(4)(+) transport, maintaining low internal levels of ammonia. To prevent a back flux of NH(3), these air-breathing fish can increase gill acid excretion and reduce the membrane NH(3) permeability by modifying the phospholipid and cholesterol compositions of their skin. Several air-breathing fish species can excrete ammonia into air through NH(3) volatilization. Some fish detoxify ammonia to glutamine or urea. The brains of some fish can tolerate much higher levels of ammonia than other animals. Studies of these fish may offer insights into the nature of ammonia toxicity in general.

  14. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...

  15. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...

  16. Hydrogen breath test in schoolchildren.

    PubMed Central

    Douwes, A C; Schaap, C; van der Klei-van Moorsel, J M

    1985-01-01

    The frequency of negative hydrogen breath tests due to colonic bacterial flora which are unable to produce hydrogen was determined after oral lactulose challenge in 98 healthy Dutch schoolchildren. There was a negative result in 9.2%. The probability of a false normal lactose breath test (1:77) was calculated from these results together with those from a separate group of children with lactose malabsorption (also determined by hydrogen breath test). A study of siblings and mothers of subjects with a negative breath test did not show familial clustering of this condition. Faecal incubation tests with various sugars showed an increase in breath hydrogen greater than 100 parts per million in those with a positive breath test while subjects with a negative breath test also had a negative faecal incubation test. The frequency of a false negative hydrogen breath test was higher than previously reported, but this does not affect the superiority of this method of testing over the conventional blood glucose determination. PMID:4004310

  17. Honey and green/black tea consumption may reduce the risk of Helicobacter pylori infection.

    PubMed

    Boyanova, Lyudmila; Ilieva, Juliana; Gergova, Galina; Vladimirov, Borislav; Nikolov, Rossen; Mitov, Ivan

    2015-05-01

    The aim of the study was to evaluate the influence of dietary and demographic factors and some habits on the prevalence of Helicobacter pylori infection in 150 dyspeptic patients examined endoscopically and by the urea breath test. Positivity rate was lower (50.6%) in patients consuming honey ≥1 day weekly compared with the remainder (70.8%) and in those consuming green/black tea ≥1 day weekly (45.2%) compared with the other patients (64.8%). Logistic regression confirmed that the factors associated with significantly lower H. pylori positivity rate were the consumption of honey (odds ratio [OR], 0.38; 95% confidence interval [CI], 0.19-0.78) and green/black tea (OR, 0.45; 95% CI, 0.21-0.95). In conclusion, honey and green/black tea intake is associated with reduced prevalence of H. pylori infection. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Perforated peptic ulcer in an adolescent girl.

    PubMed

    Schwartz, Shepard; Edden, Yair; Orkin, Boris; Erlichman, Matityahu

    2012-07-01

    A perforated peptic ulcer in a child is a rare entity. Severe abdominal pain in an ill-appearing child with a rigid abdomen and possibly with signs of shock is the typical presenting feature of this life-threatening complication of peptic ulcer disease. We present a case of a 14.5-year-old adolescent girl who developed abdominal and shoulder pain that resolved after 1 day. She was then completely well for 2 days until the abdominal and shoulder pain recurred. On examination, she appeared well, but in pain. A chest radiograph revealed a large pneumoperitoneum. She underwent emergent laparoscopic omental patch repair of a perforated ulcer on the anterior wall of her stomach. Result of a urea breath test to detect Helicobacter pylori was negative. The differential diagnosis of pneumoperitoneum in children is discussed, as are childhood perforated peptic ulcer in general, and the unique clinical features present in this case in particular.

  19. Milk urea testing as a tool to monitor reproductive performance in Ontario dairy herds.

    PubMed

    Godden, S M; Kelton, D F; Lissemore, K D; Walton, J S; Leslie, K E; Lumsden, J H

    2001-06-01

    Dairy herd improvement test-day data, including milk urea concentrations measured using infrared test method, were collected from 60 commercial Ontario Holstein dairy herds for a 13-mo period between December 1, 1995, and December 31, 1996. The objective of the study was to describe, at the cow and the group level, the relationship between DHI milk urea concentrations and reproductive performance in commercial dairy herds. When interpreted at the cow level, there was no association between milk urea and the risk for pregnancy from an insemination occurring within the 45-d period preceding test day. However, a negative curvilinear relationship existed between milk urea and the risk for pregnancy from a first, second, or third insemination event occurring within the 45-d period following test day, with the odds for pregnancy being highest when the milk urea on the test day preceding the insemination was either below 4.5 mmol/L or greater than 6.49 mmol/L, compared with a concentration between 4.5 and 6.49 mmol/L. When interpreted at the group level, there was no association between group mean milk urea for cows between 50 and 180 DIM, and the group conception rate for cows receiving a first, second, or third insemination event in the 45-d period either preceding or following test day. Thus, while DHI milk urea measurements may be useful as a management tool to improve the efficiency of production or reduce nitrogen excretion, through helping to optimize the efficiency of protein utilization, they may have limited utility as a monitoring or diagnostic tool for reproductive performance. The results of this study suggest that good fertility may be achieved across a broad range of milk urea concentrations.

  20. The effect of breath freshener strips on two types of breath alcohol testing instruments.

    PubMed

    Moore, Ronald L; Guillen, Jennifer

    2004-07-01

    The potential for breath freshener strips to interfere with the accuracy of a breath alcohol test was studied. Twelve varieties of breath freshener strips from five manufacturers were examined. Breath tests were conducted using the infrared based BAC DataMaster or the fuel cell based Alco-Sensor IV-XL, 30 and 150 seconds after placing a breath strip on the tongue. No effect was observed using the Alco-Sensor system. Some of the strips gave a small reading at 30 seconds (less than or equal to 0.010 g/210 L apparent alcohol) using the DataMaster. Readings on the DataMaster returned to zero by the 150 second test. A proper pre-test observation and deprivation period should prevent any interference from breath freshener strips on breath alcohol testing.

  1. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breath-alcohol test system. 862.3050 Section 862....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened to measure alcohol in the human breath. Measurements obtained by this device are used in the...

  2. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breath-alcohol test system. 862.3050 Section 862....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened to measure alcohol in the human breath. Measurements obtained by this device are used in the...

  3. Impact of Helicobacter pylori Eradication Therapy on Platelet Counts in Patients With Chronic Idiopathic Thrombocytopenic Purpura

    PubMed Central

    Amiri, Mohamadreza

    2016-01-01

    This study was a before and after clinical evaluation of Helicobacter pylori eradication on platelet counts in a group of 23 patients with chronic Idiopathic (Autoimmune) thrombocytopenic purpura (CITP). H. pylori infection was identified in patients by a 13C-urea breath test and confirmed by an H. pylori stool antigen test. Eradication was conducted in patients testing positive. Infected (n = 10) and uninfected (n = 13) patient groups did not differ with respect to age, gender, history of previous splenectomy, treatment with anti-D, current treatment with corticosteroids, or initial platelet counts. H. pylori eradication was successful in eight infected CITP patients, with two patients not responsive to treatment. Compared to the uninfected group, patients in the infected group who responded to eradication therapy had significantly increased platelet counts after six months (56.2 ± 22.2 vs. 233 ± 85.6 ×103 million cells/L; P < 0.01), whereas platelet counts in the non-responding patients and uninfected group did not differ after this period of time. H. pylori eradication promotes significant platelet count improvement in patients with CITP. Thus, all patients with CITP should be tested and treated for H. pylori infections. PMID:26925898

  4. The glucose breath test: a diagnostic test for small bowel stricture(s) in Crohn's disease.

    PubMed

    Mishkin, Daniel; Boston, Francis M; Blank, David; Yalovsky, Morty; Mishkin, Seymour

    2002-03-01

    The aim of this study was to determine whether an indirect noninvasive indicator of proximal bacterial overgrowth, the glucose breath test, was of diagnostic value in inflammatory bowel disease. Twenty four of 71 Crohn's disease patients tested had a positive glucose breath test. No statistical conclusions could be drawn between the Crohn's disease activity index and glucose breath test status. Of patients with radiologic evidence of small bowel stricture(s), 96.0% had a positive glucose breath test, while only one of 46 negative glucose breath test patients had a stricture. The positive and negative predictive values for a positive glucose breath test as an indicator of stricture formation were 96.0% and 97.8%, respectively. This correlation was not altered in Crohn's disease patients with fistulae or status postresection of the terminal ileum. The data in ulcerative colitis were nondiagnostic. In conclusion, the glucose breath test appears to be an accurate noninvasive inexpensive diagnostic test for small bowel stricture(s) and secondary bacterial overgrowth in Crohn's disease.

  5. A study on the indirect urea dosing method in the Selective Catalytic Reduction system

    NASA Astrophysics Data System (ADS)

    Brzeżański, M.; Sala, R.

    2016-09-01

    This article presents the results of studies on concept solution of dosing urea in a gas phase in a selective catalytic reduction system. The idea of the concept was to heat-up and evaporate the water urea solution before introducing it into the exhaust gas stream. The aim was to enhance the processes of urea converting into ammonia, what is the target reductant for nitrogen oxides treatment. The study was conducted on a medium-duty Euro 5 diesel engine with exhaust line consisting of DOC catalyst, DPF filter and an SCR system with a changeable setup allowing to dose the urea in liquid phase (regular solution) and to dose it in a gas phase (concept solution). The main criteria was to assess the effect of physical state of urea dosed on the NOx conversion ratio in the SCR catalyst. In order to compare both urea dosing methods a special test procedure was developed which consisted of six test steps covering a wide temperature range of exhaust gas generated at steady state engine operation condition. Tests were conducted for different urea dosing quantities defined by the a equivalence ratio. Based on the obtained results, a remarkable improvement in NOx reduction was found for gas urea application in comparison to the standard liquid urea dosing. Measured results indicate a high potential to increase an efficiency of the SCR catalyst by using a gas phase urea and provide the basis for further scientific research on this type of concept.

  6. 13C-methacetin and 13C-galactose breath tests can assess restricted liver function even in early stages of primary biliary cirrhosis.

    PubMed

    Holtmeier, Julia; Leuschner, Maria; Schneider, Arne; Leuschner, Ulrich; Caspary, Wolfgang F; Braden, Barbara

    2006-11-01

    The 13C-methacetin breath test quantitatively evaluates cytochrome P450-dependent liver function. The 13C-galactose breath test non-invasively measures the galactose oxidation capacity of the liver. The aim of this study was to find out whether these breath tests are sensitive parameters also in non-cirrhotic patients with primary biliary cirrhosis. Nineteen patients with early-stage primary biliary cirrhosis (no cirrhotic alterations in the liver biopsy, Ludwig stage I-III) and 20 healthy controls underwent the 13C-methacetin and 13C-galactose breath tests. Patients with primary biliary cirrhosis metabolized less 13C-methacetin than controls (cumulative recovery within 30 min 7.5+/-2.4% versus 14.0+/-2.6%; p < 0.001). When a cut-off > 9.8% was used for the cumulative recovery after 30 min, the methacetin breath test reached 84.2% sensitivity and 95.0 specificity. In the 13C-galactose breath test, the percentage recovery at 60 min in patients was 3.1+/-1.3%/h, and 6.3+/-1.1%/h in controls (p < 0.001). Using a cut-off > 4.7%/h, the galactose breath test reached 89.5% sensitivity and 95.0 specificity. In non-cirrhotic, early-stage, primary biliary cirrhosis the 13C-methacetin breath test and the 13C-galactose breath test reliably indicate decreased liver function. The 13C-galactose breath test can also predict the histological score.

  7. Measurement of hepatic functional mass by means of 13C-methacetin and 13C-phenylalanine breath tests in chronic liver disease: Comparison with Child-Pugh score and serum bile acid levels

    PubMed Central

    Festi, D.; Capodicasa, S.; Sandri, L.; Colaiocco-Ferrante, L.; Staniscia, T.; Vitacolonna, E.; Vestito, A.; Simoni, P.; Mazzella, G.; Portincasa, P.; Roda, E.; Colecchia, A.

    2005-01-01

    AIM: To evaluate and compare the clinical usefulness of 13C-phenylalanine and 13C-methacetin breath tests in quantitating functional hepatic mass in patients with chronic liver disease and to further compare these results with those of conventional tests, Child-Pugh score and serum bile acid levels. METHODS: One hundred and forty patients (50 HCV- related chronic hepatitis, 90 liver cirrhosis patients) and 40 matched healthy controls were studied. Both breath test and routine liver test, serum levels of cholic and chenodeoxycholic acid conjugates were evaluated. RESULTS: Methacetin breath test, expressed as 60 min cumulative percent of oxidation, discriminated the hepatic functional capacity not only between controls and liver disease patients, but also between different categories of chronic liver disease patients. Methacetin breath test was correlated with liver function tests and serum bile acids. Furthermore, methacetin breath test, as well as serum bile acids, were highly predictive of Child-Pugh scores. The diagnostic power of phenylalanine breath test was always less than that of methacetin breath test. CONCLUSION: Methacetin breath test represents a safe and accurate diagnostic tool in the evaluation of hepatic functional mass in chronic liver disease patients. PMID:15609414

  8. Validation of the salivary urea and creatinine tests as screening methods of chronic kidney disease in Vietnamese patients.

    PubMed

    Pham, Thuy Anh Vu

    2017-11-01

    The aims of this case control study were to correlate the serum and salivary urea as well as creatinine levels; and to evaluate salivary urea and creatinine as noninvasive alternatives to serum for creatinine estimation in chronic kidney disease (CKD) patients. Blood and saliva samples were collected from 112 CKD patients and 108 subjects without CKD for quantitative analysis of urea and creatinine. Spearman's correlation coefficients between salivary and serum urea as well as creatinine were obtained. Receiver operating characteristic analysis was done to assess the diagnostic tests of salivary urea and creatinine. Cut-off values were determined based on the best trade-off between the sensitivity and specificity for both salivary urea and creatinine. Salivary urea and creatinine concentrations were significantly higher in CKD patients than those in control subjects; and increased by the stages of the severity of the disease. The positive correlation was significantly found between salivary and serum creatinine (r  =  0.90) and between salivary and serum urea (r  =  0.73). Area under the curve for salivary urea was 0.76 and a cut-off value of 14.25 mmol/L gave a sensitivity of 82.9% and specificity of 57.8%. Area under the curve for salivary creatinine was 0.92 and a cut-off value of 0.24 mg/dL gave a sensitivity of 86.5% and specificity of 87.2%. Both salivary urea and creatinine have a high capacity for serum creatinine estimation. Salivary urea and creatinine tests can be used as low-cost, easily accessible and noninvasive tools for screening, diagnosing, monitoring treatment outcomes and ascertaining prognosis of chronic kidney disease.

  9. Salivary levels of phosphorus and urea as indices of their plasma levels in nephropathic patients.

    PubMed

    Bilancio, Giancarlo; Cavallo, Pierpaolo; Lombardi, Cinzia; Guarino, Ermanno; Cozza, Vincenzo; Giordano, Francesco; Palladino, Giuseppe; Cirillo, Massimo

    2018-03-30

    Phosphorus and urea are measurable in saliva. Measurements of saliva phosphorus (S-Pho) and saliva urea (S-Urea) could be useful because of low invasivity. Data are limited to saliva tests methodology and to correlations between plasma and saliva compositions. S-Pho and S-Urea were investigated focusing on blind duplicates, differences between collection sites, differences between collection times, freezing-thawing effects, and plasma-saliva correlations. Tests were performed using fresh saliva collected by synthetic swap early morning after overnight fast (standard). Methodology was investigated in fifteen healthy volunteers. Plasma-saliva correlations were investigated in thirty nephropathic outpatients. S-Pho and S-Urea in all measurements ranged above detection limits (0.3 mmol/L). In healthy volunteers, S-Pho and S-Urea were similar in duplicates (results for S-Pho and S-Urea: % difference between samples ≤ 4.85%; R between samples ≥ .976, P < .001), in samples from different mouth sites (≤4.24%; R ≥ .887, P < .001), and in samples of different days (≤5.61%; R ≥ .606, P < .01) but, compared to standard, were substantially lower in after-breakfast samples (-28.0% and -21.3%; R ≥ .786, P < .001) and slightly lower in frozen-thawed samples (-12.4% and -5.92%; R ≥ .742, P < .001). In nephropathic patients, S-Pho was higher than but correlated with plasma phosphorus (saliva/plasma ratio 4.80; R = .686, P < .001), whereas S-Urea and plasma urea were similar and correlated with each other (saliva/plasma ratio 0.96; R = .944, P < .001). Post-dialysis changes in S-Pho and S-Urea paralleled post-dialysis changes in plasma phosphorus and urea. S-Pho and S-Urea reflect plasma phosphorus and plasma urea. Early morning fasting fresh samples are advisable because collection time and freezing-thawing affect saliva tests. © 2018 Wiley Periodicals, Inc.

  10. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  11. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  12. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  13. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  14. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  15. The association of pagophagia with Helicobacter pylori infection in patients with iron-deficiency anemia.

    PubMed

    Asma, Suheyl; Boga, Can; Ozdogu, Hakan; Serin, Ender

    2009-07-01

    This study aimed to determine the relationship between pagophagia (compulsive ice eating) and H. pylori infection in patients with iron-deficiency anemia. We identified H. pylori infection using the (13)C-urea breath test in 45 patients with iron-deficiency anemia (group 1) and 55 patients with iron-deficiency anemia and pagophagia (group 2). Subgroups for testing oral intestinal iron absorption were randomly assigned from both groups. These subgroups consisted of (a) 10 patients with iron-deficiency anemia, (b) 10 patients with iron-deficiency anemia and pagophagia, (c) 10 patients with iron-deficiency anemia, pagophagia, and H. pylori infection before the eradication of H. pylori and (d) subgroup c after eradication therapy. There was no difference in the rate of H. pylori infection in the iron-deficiency anemia groups, with or without pagophagia. Furthermore, oral intestinal iron absorption was not influenced by pagophagia and/or H. pylori infection. Pagophagia did not increase the risk of H. pylori infection in patients with iron-deficiency anemia. Pagophagia and H. pylori infection do not synergistically affect the development of intestinal iron absorption abnormalities.

  16. Influence of Helicobacter pylori, sex, and age on serum gastrin and pepsinogen concentrations in subjects without symptoms and patients with duodenal ulcers.

    PubMed Central

    Mossi, S; Meyer-Wyss, B; Renner, E L; Merki, H S; Gamboni, G; Beglinger, C

    1993-01-01

    The relation between Helicobacter pylori (H pylori) infection and fasting gastrin and pepsinogen-I and -II concentrations was evaluated in 278 volunteers without symptoms and the results were compared with the values obtained in 35 patients with duodenal ulcers. H pylori infection was determined with the 13C-urea breath test in subjects without symptoms and with endoscopy, biopsy (histology and culture), and quick urease test (CLO-test) in patients with duodenal ulcers. Gastrin and pepsinogen-I and -II concentrations were assayed with specific radioimmunoassay systems. The results clearly indicate that fasting gastrin and pepsinogen-I and -II concentrations were significantly higher in H pylori positive compared with H pylori negative subjects. Neither age nor sex affected basal gastrin and pepsinogen concentrations in H pylori negative subjects. Fasting gastrin, pepsinogen-I and -II concentrations in serum samples were similar in H pylori positive persons with no symptoms and those with duodenal ulcers suggesting that similar mechanisms are involved in increasing plasma concentrations of these variables in both populations. Hypergastrinaemia and hyperpepsinogenaemia are therefore probably secondary to active H pylori infection. PMID:8314506

  17. Novel urea and bis-urea primaquine derivatives with hydroxyphenyl or halogenphenyl substituents: Synthesis and biological evaluation.

    PubMed

    Perković, I; Antunović, M; Marijanović, I; Pavić, K; Ester, K; Kralj, M; Vlainić, J; Kosalec, I; Schols, D; Hadjipavlou-Litina, D; Pontiki, E; Zorc, B

    2016-11-29

    A series of novel compounds 3a-j and 6a-j with primaquine and hydroxyl or halogen substituted benzene moieties bridged by urea or bis-urea functionalities were designed, synthesized and evaluated for biological activity. The title compounds were prepared using benzotriazole as the synthon, through several synthetic steps. 3-[3,5-Bis(trifluoromethyl)phenyl]-1-{4-[(6-methoxyquinolin-8-yl)amino]pentyl}urea (3j) was the most active urea and 1-[({4-[(6-methoxyquinolin-8-yl)amino]pentyl}carbamoyl)amino]-3-[3-(trifluoromethyl)phenyl]urea (6h) the most active bis-urea derivative in antiproliferative screening in vitro against eight tested cancer cell lines. Urea derivatives 3a-g with hydroxy group or one halogen atom showed moderate antiproliferative effects against all the tested cell lines, but stronger activity against breast carcinoma MCF-7 cell line, while trifluoromethyl derivatives 3h-j showed antiproliferative effects against all the tested cell lines in low micromolar range. Finally, bis-ureas with hydroxy and fluoro substituents 6a-d showed extreme selectivity and chloro or bromo derivatives 6e-g high selectivity against MCF-7 cells (IC 50 0.1-2.6 μM). p-Fluoro derivative 6d, namely 3-(4-fluorophenyl)-1-[({4-[(6-methoxyquinolin-8-yl)amino]pentyl}carbamoyl)amino]urea, is the most promising compound. Further biological experiments showed that 6d affected cell cycle and induced cell death of MCF-7 cell line. Due to its high activity against MCF-7 cell line (IC 50 0.31 μM), extreme selectivity and full agreement with the Lipinski's and Gelovani's rules for prospective small molecular drugs, 6d may be considered as a lead compound in development of breast carcinoma drugs. Urea 3b and almost all bis-ureas showed high antioxidant activity in DPPH assay, but urea derivatives were more active in lipid peroxidation test. Only few compounds exhibited weak inhibition of soybean lipoxygenase. Compound 3j exhibited the strongest antimicrobial activity in susceptibility assay in vitro (MIC = 1.6-12.5 μg ml -1 ). Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. New monoclonal antibody-based test for Helicobacter pylori urease in gastric tissue.

    PubMed

    Kim, Do Hyun; Kim, Ho Dong; Park, Hyeuk; Choi, Seung; Beom, Jae Won; Kim, Woo Jong; Park, Chang Kook; Lee, Young Jik; Park, Ju Young; Kim, Hyung Rag; Park, Chul; Joo, Young Eun; Jung, Young Do

    2016-01-01

    To evaluate a new monoclonal antibody for Helicobacter pylori urease in gastric tissue. A total of 107 volunteers were enrolled. All subjects underwent a (13)C-urea breath test and esophagogastroduodenoscopy. Gastric aspirates were analyzed for pH and ammonia. Six biopsy specimens in the gastric antrum and body were obtained for a rapid urease test and histology. The new monoclonal antibody-based H. pylori urease test (HPU) was performed to rapidly and qualitatively detect urease in two biopsy specimens. H. pylori infection was diagnosed in 73 subjects. The sensitivity and specificity of the HPU was 89% and 74%, respectively. The subjects were divided into two groups: one with true-positive and true-negative HPU results (n = 90) and the other with false-positive and false-negative HPU results (n = 17). Across all subjects, ammonia levels were 900.5 ± 646.7 and 604.3 ± 594.3 μmol/L (p > 0.05), and pH was 3.37 ± 1.64 and 2.82 ± 1.51 (p > 0.05). Sensitivity was higher in the presence of atrophic gastritis or intestinal metaplasia. HPU detected H. pylori in approximately 10 min. Gastric aspirate ammonia and pH levels did not affect the test results. Sensitivity was good in the presence of atrophic gastritis or intestinal metaplasia.

  19. Results of the first semi-annual qualification testing of devices to measure breath alcohol

    DOT National Transportation Integrated Search

    1975-01-01

    Eight evidential breath testers were performance tested according to the Standard for Devices to Measure Breath Alcohol Federal Register, Vol 38, No. 212, November 5, 1973. In addition, a prototype breath tester not commercially available was tested....

  20. Detection of Interstellar Urea with Carma

    NASA Astrophysics Data System (ADS)

    Kuo, H.-L.; Snyder, L. E.; Friedel, D. N.; Looney, L. W.; McCall, B. J.; Remijan, A. J.; Lovas, F. J.; Hollis, J. M.

    2010-06-01

    Urea, a molecule discovered in human urine by H. M. Rouelle in 1773, has a significant role in prebiotic chemistry. Previous BIMA observations have suggested that interstellar urea [(NH_2)_2CO] is a compact hot core molecule such as other large molecules, e.g. methyl formate and acetic acid (2009, 64th OSU Symposium On Molecular Spectroscopy, WI05). We have conducted an extensive search for urea toward the high mass hot molecular core Sgr B2(N-LMH) using CARMA and the IRAM 30 m. Because the spectral lines of heavy molecules like urea tend to be weak and hot cores display lines from a wide range of molecules, a major problem in identifying urea lines is confusion with lines of other molecules. Therefore, it is necessary to detect a number of urea lines and apply sophisticated statistical tests before having confidence in an identification. The 1 mm resolution of CARMA enables favorable coupling of the source size and synthesized beam size, which was found to be essential for the detection of weak signals. The 2.5^"×2^" synthesized beam of CARMA significantly resolves out the contamination by extended emission and reveals the eight weak urea lines that were previously blended with nearby transitions. Our analysis indicates that these lines are likely to be urea since the resulting observed line frequencies are coincident with a set of overlapping connecting urea lines, and the observed line intensities are consistent with the expected line strengths of urea. In addition, we have developed a new statistical approach to examine the spatial correlation between the observed lines by applying the Student T-test to the high resolution channel maps obtained from CARMA. The T-test shows similar spatial distributions from all eight candidate lines, suggesting a common molecular origin, urea. Our T-test method could have a broad impact on the next generation of arrays, such as ALMA, because the new arrays will require a method to systematically determine the credibility of detections of weaker signals from new and larger interstellar molecules.

  1. Fecal /sup 13/C analysis for the detection and quantitation of intestinal malabsorption

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, P.D.; MacLean, W.C. Jr.; Watkins, J.B.

    Use of /sup 14/CO/sub 2/ breath tests and fecal analyses for the detection and quantitation of intestinal malabsorption has been extensively documented in adult subjects. The use of radioisotopes has extended the range of breath test applications to include pediatric and geriatric subjects. Here we report a fecal /sup 13/C analysis that can be used in conjunction with /sup 14/CO/sub 2/ breath tests. Twenty-four-hour fecal samples were collected before and after the administration of a labeled substrate. Simultaneous cholyglycine /sup 13/CO/sub 2/ breath tests and fecal assays were performed in five children. One child with bacterial overgrowth had an abnormalmore » breath test and a normal fecal test. Of three children with ileal dysfunction, only one had an abnormal breath test, whereas the fecal test was abnormal in all three. Both the breath test and fecal test were abnormal for a child who had undergone an ileal resection. Both tests were normal for a child with ulcerative colitis.« less

  2. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Apparatus § 84.88 Breathing bag test. (a) Breathing bags will be tested in an air atmosphere saturated with... Institute upon request. (d) The air within the bag(s) shall not contain more than 100 parts per million of... 42 Public Health 1 2014-10-01 2014-10-01 false Breathing bag test. 84.88 Section 84.88 Public...

  3. Defences against ammonia toxicity in tropical air-breathing fishes exposed to high concentrations of environmental ammonia: a review.

    PubMed

    Ip, Y K; Chew, S F; Wilson, J M; Randall, D J

    2004-10-01

    In the tropics, air-breathing fishes can be exposed to environmental ammonia when stranded in puddles of water during the dry season, during a stay inside a burrow, or after agricultural fertilization. At low concentrations of environmental ammonia, NH(3) excretion is impeded, as in aerial exposure, leading to the accumulation of endogenous ammonia. At high concentrations of environmental ammonia, which results in a reversed NH(3) partial pressure gradient (DeltaP(NH3)), there is retention of endogenous ammonia and uptake of exogenous ammonia. In this review, several tropical air-breathing fishes (giant mudskipper, African catfish, oriental weatherloach, swamp eel, four-eyed sleeper, abehaze and slender African lungfish), which can tolerate high environmental ammonia exposure, are used as examples to demonstrate how eight different adaptations can be involved in defence against ammonia toxicity. Four of these adaptations deal with ammonia toxicity at branchial and/or epithelial surfaces: (1) active excretion of NH(4)(+); (2) lowering of environmental pH; (3) low NH(3) permeability of epithelial surfaces; and (4) volatilization of NH(3), while another four adaptations ameliorate ammonia toxicity at the cellular and subcellular levels: (5) high tolerance of ammonia at the cellular and subcellular levels; (6) reduction in ammonia production; (7) glutamine synthesis; and (8) urea synthesis. The responses of tropical air-breathing fishes to high environmental ammonia are determined apparently by behavioural adaptations and the nature of their natural environments.

  4. Clinical significance of the glucose breath test in patients with inflammatory bowel disease.

    PubMed

    Lee, Ji Min; Lee, Kang-Moon; Chung, Yoon Yung; Lee, Yang Woon; Kim, Dae Bum; Sung, Hea Jung; Chung, Woo Chul; Paik, Chang-Nyol

    2015-06-01

    Small intestinal bacterial overgrowth which has recently been diagnosed with the glucose breath test is characterized by excessive colonic bacteria in the small bowel, and results in gastrointestinal symptoms that mimic symptoms of inflammatory bowel disease. This study aimed to estimate the positivity of the glucose breath test and investigate its clinical role in inflammatory bowel disease. Patients aged > 18 years with inflammatory bowel disease were enrolled. All patients completed symptom questionnaires. Fecal calprotectin level was measured to evaluate the disease activity. Thirty historical healthy controls were used to determine normal glucose breath test values. A total of 107 patients, 64 with ulcerative colitis and 43 with Crohn's disease, were included. Twenty-two patients (20.6%) were positive for the glucose breath test (30.2%, Crohn's disease; 14.1%, ulcerative colitis). Positive rate of the glucose breath test was significantly higher in patients with Crohn's disease than in healthy controls (30.2% vs 6.7%, P=0.014). Bloating, flatus, and satiety were higher in glucose breath test-positive patients than glucose breath test-negative patients (P=0.021, 0.014, and 0.049, respectively). The positivity was not correlated with the fecal calprotectin level. The positive rate of the glucose breath test was higher in patients with inflammatory bowel disease, especially Crohn's disease than in healthy controls; gastrointestinal symptoms of patients with inflammatory bowel disease were correlated with this positivity. Glucose breath test can be used to manage intestinal symptoms of patients with inflammatory bowel disease. © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  5. UREA/ammonium ion removal system for the orbiting frog otolith experiment. [ion exchange resins for water treatment during space missions

    NASA Technical Reports Server (NTRS)

    Schulz, J. R.; Anselmi, R. T.

    1976-01-01

    The feasibility of using free urease enzyme and ANGC-101 ion exchange resin to remove urea and ammonium ion for space system waste water applications was studied. Specifically examined is the prevention of urea and ammonia toxicity in a 30-day Orbiting Frog Otolith (OFO) flight experiment. It is shown that free urease enzyme used in conjunction with ANGC-101 ion-exchange resin and pH control can control urea and amonium ion concentration in unbuffered recirculating water. In addition, the resin does not adversely effect the bullfrogs by lowering the concentration of cations below critical minimum levels. Further investigations on bioburden control, frog waste excretion on an OFO diet, a trade-off analysis of methods of automating the urea/ammonium ion removal system and fabrication and test of a semiautomated breadboard were recommended as continuing efforts. Photographs of test equipment and test animals are shown.

  6. Laboratory testing of two prototype in-vehicle breath test devices

    DOT National Transportation Integrated Search

    1985-08-01

    This report presents the results of laboratory testing of two recently developed prototype in-vehicle breath test devices. These devices are designed to prevent persons with alcohol on their breath from driving a car. The devices tested were the SOBE...

  7. Detection of Interstellar Urea

    NASA Astrophysics Data System (ADS)

    Kuo, Hsin-Lun; Remijan, Anthony J.; Snyder, Lewis E.; Looney, Leslie W.; Friedel, Douglas N.; Lovas, Francis J.; McCall, Benjamin J.; Hollis, Jan M.

    2010-11-01

    Urea, a molecule discovered in human urine by H. M. Rouelle in 1773, has a significant role in prebiotic chemistry. Previous BIMA observations have suggested that interstellar urea [(NH2)2CO] is a compact hot core molecule such as other large molecules (e.g. methyl formate and acetic acid). We have conducted an extensive search for urea toward the high mass hot molecular core Sgr B2(N-LMH) using BIMA, CARMA and the IRAM 30 m. Because the spectral lines of heavy molecules like urea tend to be weak and hot cores display lines from a wide range of molecules, it is necessary to detect a number of urea lines and apply sophisticated statistical tests before having confidence in an identification. The 1 mm resolution of CARMA enables favorable coupling of the source size and synthesized beam size, which was found to be essential for the detection of weak signals. We have detected a total of 65 spectral lines (32 molecular transitions and 33 unidentified transitions), most of which are narrower than the SEST survey (Nummelin et al. 1998) due to the small synthesized beam (2.5" x 2") of CARMA. It significantly resolves out the contamination by extended emission and reveals the eight weak urea lines that were previously blended with nearby transitions. Our analysis indicates that these lines are likely to be urea since the resulting observed line frequencies are coincident with a set of overlapping connecting urea lines, and the observed line intensities are consistent with the expected line strengths of urea. In addition, we have developed a new statistical approach to examine the spatial correlation between the observed lines by applying the Student's t test to the high resolution channel maps obtained from CARMA. The t test shows consistent spatial distributions from all eight candidate lines, suggesting a common molecular origin, urea. Our t test method could have a broad impact on the next generation of arrays, such as ALMA, because the new arrays will require a method to systematically determine the credibility of detections of weaker signals from new and larger interstellar molecules.

  8. BUN (Blood Urea Nitrogen): MedlinePlus Lab Test Information

    MedlinePlus

    ... BUN (Blood Urea Nitrogen) URL of this page: https://medlineplus.gov/labtests/bunbloodureanitrogen.html BUN (Blood Urea ... Jan 30]; 4(2):223–33. Available from: https://www.ncbi.nlm.nih.gov/pubmed/3516645 Mayo ...

  9. Additional Value of CH4 Measurement in a Combined 13C/H2 Lactose Malabsorption Breath Test: A Retrospective Analysis

    PubMed Central

    Houben, Els; De Preter, Vicky; Billen, Jaak; Van Ranst, Marc; Verbeke, Kristin

    2015-01-01

    The lactose hydrogen breath test is a commonly used, non-invasive method for the detection of lactose malabsorption and is based on an abnormal increase in breath hydrogen (H2) excretion after an oral dose of lactose. We use a combined 13C/H2 lactose breath test that measures breath 13CO2 as a measure of lactose digestion in addition to H2 and that has a better sensitivity and specificity than the standard test. The present retrospective study evaluated the results of 1051 13C/H2 lactose breath tests to assess the impact on the diagnostic accuracy of measuring breath CH4 in addition to H2 and 13CO2. Based on the 13C/H2 breath test, 314 patients were diagnosed with lactase deficiency, 138 with lactose malabsorption or small bowel bacterial overgrowth (SIBO), and 599 with normal lactose digestion. Additional measurement of CH4 further improved the accuracy of the test as 16% subjects with normal lactose digestion and no H2-excretion were found to excrete CH4. These subjects should have been classified as subjects with lactose malabsorption or SIBO. In conclusion, measuring CH4-concentrations has an added value to the 13C/H2 breath test to identify methanogenic subjects with lactose malabsorption or SIBO. PMID:26371034

  10. Osmolality Test

    MedlinePlus

    ... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... osmotic gap, tests for blood sodium, blood urea nitrogen (BUN) , and glucose must be performed to calculate ...

  11. Pulmonary Function Testing in Children

    MedlinePlus

    ... breathing test. About 15 minutes after taking the medicine, your child will repeat the breathing test. The results from ... the first test to find out if the medicine has improved your child’s breathing. Why shouldn’t I give my child ...

  12. Chemical sensors for breath gas analysis: the latest developments at the Breath Analysis Summit 2013.

    PubMed

    Tisch, Ulrike; Haick, Hossam

    2014-06-01

    Profiling the body chemistry by means of volatile organic compounds (VOCs) in the breath opens exciting new avenues in medical diagnostics. Gas sensors could provide ideal platforms for realizing portable, hand-held breath testing devices in the near future. This review summarizes the latest developments and applications in the field of chemical sensors for diagnostic breath testing that were presented at the Breath Analysis Summit 2013 in Wallerfangen, Germany. Considerable progress has been made towards clinically applicable breath testing devices, especially by utilizing chemo-sensitive nanomaterials. Examples of several specialized breath testing applications are presented that are either based on stand-alone nanomaterial-based sensors being highly sensitive and specific to individual breath compounds over others, or on combinations of several highly specific sensors, or on experimental nanomaterial-based sensors arrays. Other interesting approaches include the adaption of a commercially available MOx-based sensor array to indirect breath testing applications, using a sample pre-concentration method, and the development of compact integrated GC-sensor systems. The recent trend towards device integration has led to the development of fully integrated prototypes of point-of-care devices. We describe and compare the performance of several prototypes that are based on different sensing technologies and evaluate their potential as low-cost and readily available next-generation medical devices.

  13. Sensing the effects of mouth breathing by using 3-tesla MRI

    NASA Astrophysics Data System (ADS)

    Park, Chan-A.; Kang, Chang-Ki

    2017-06-01

    We investigated the effects of mouth breathing and typical nasal breathing on brain function by using blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI). The study had two parts: the first test was a simple contrast between mouth and nasal breathing, and the second test involved combined breathing modes, e.g., mouth inspiration and nasal expiration. Eleven healthy participants performed the combined breathing task while undergoing 3T fMRI. In the group-level analysis, contrast images acquired by using an individual participantlevel analysis were processed using the one-sample t test. We also conducted a region-of-interest analysis comparing signal intensity changes between the breathing modes; the region was selected using an automated anatomical labeling map. The results demonstrated that the BOLD signal in the hippocampus and brainstem was significantly decreased in mouth breathing relative to nasal breathing. On the other hand, both the precentral and postcentral gyri showed activation that was more significant in mouth breathing compared to nasal breathing. This study suggests that the BOLD activity patterns between mouth and nasal breathing may be induced differently, especially in the hippocampus, which could provide clues to explain the effects on brain cognitive function due to mouth breathing.

  14. [*C]octanoic acid breath test to measure gastric emptying rate of solids.

    PubMed

    Maes, B D; Ghoos, Y F; Rutgeerts, P J; Hiele, M I; Geypens, B; Vantrappen, G

    1994-12-01

    We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [14C]octanoic acid or [13C]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.

  15. News from the Breath Analysis Summit 2011.

    PubMed

    Corradi, Massimo; Mutti, Antonio

    2012-06-01

    This special section highlights some of the important work presented at the Breath Analysis Summit 2011, which was held in Parma (Italy) from 11 to 14 September 2011. The meeting, which was jointly organized by the International Association for Breath Research and the University of Parma, was attended by more than 250 delegates from 33 countries, and offered 34 invited lectures and 64 unsolicited scientific contributions. The summit was organized to provide a forum to scientists, engineers and clinicians to present their latest findings and to meet industry executives and entrepreneurs to discuss key trends, future directions and technologies available for breath analysis. A major focus was on nitric oxide, exhaled breath condensate, electronic nose, mass spectrometry and newer sensor technologies. Medical applications ranged from asthma and other respiratory diseases to gastrointestinal disease, occupational diseases, critical care and cancer. Most people identify breath tests with breathalysers used by police to estimate ethanol concentration in blood. However, breath testing has far more sophisticated applications. Breath analysis is rapidly evolving as a new frontier in medical testing for disease states in the lung and beyond. Every individual has a breath fingerprint-or 'breathprint'-that can provide useful information about his or her state of health. This breathprint comprises the many thousands of molecules that are expelled with each breath we exhale. Breath research in the past few years has uncovered the scientific and molecular basis for such clinical observations. Relying on mass spectrometry, we have been able to identify many such unique substances in exhaled breath, including gases, such as nitric oxide (NO) and carbon monoxide (CO), and a wide array of volatile organic compounds. Exhaled breath also carries aerosolized droplets that can be collected as an exhaled breath condensate that contains endogenously produced non-volatile compounds. Breath analysis is now used to diagnose and monitor asthma, check for transplant organ rejection, detect lung cancer and test for Helicobacter pyloriinfection-and the list is growing. A major milestone in the scientific study of breath was marked in the 1970s when Linus Pauling demonstrated that there is more to exhaled breath than the classic gases of nitrogen, oxygen, carbon dioxide and water vapour-a lot more. Based on the gas-liquid partition chromatography analysis, Pauling reported the presence of 250 substances in exhaled breath. We now have the technology to test for any and all of these components. The field of breath analysis has made considerable advances in the 21st century and the utility of breath analysis in health care is advancing quickly. The science is rapidly expanding, the technology is improving and several new applications have been developed or are under commercial development. Breath analysis may rely on both direct (on line) and indirect (off line) reading methods: in the on-line method, breath analysis is immediately available, whereas the use of indirect methods generally involves collecting and trapping the breath sample and subsequently transferring it to an analytical instrument for analysis. Various kinds of breath samples have been used in biological monitoring, including mixed expired air and end expired air: end exhaled air represents the alveolar air concentration and mixed exhaled air represents the gas mixture coming from the dead space of the bronchial tree and the alveolar gas-exchange space. Exhaled breath analysis is an area where the modern day advances in technology and engineering meet the ever expanding need in medicine for more sensitive, specific and non-invasive tests which makes this area a major front in the interface between medicine and engineering. A major breakthrough over the past decade has been the increase in breath-based tests approved by the US Food and Drug Administration (FDA). Devices measuring common breath gases (oxygen, nitrogen, water vapour and CO(2)) in patient respiratory monitoring have served as a platform for technological growth in clinical breath-testing applications. A few exhaled breath tests have demonstrated clinical utility and are in widespread use, and several FDA-approved devices are available. These widely used exhaled breath tests include detection of blood alcohol concentration and exhaled CO(2). Other clinical applications of exhaled breath analysis include testing for H. pylori infection, lactose intolerance, heart transplant rejection and, more recently, monitoring of airway inflammation by means of exhaled NO. Examination of exhaled breath has the potential to change the existing routine approaches in human medicine. The rapidly developing new analytical and computer technologies along with novel, unorthodox ideas are prerequisites for future advances in this field. Scientists who participated in the Breath Analysis Summit 2011 were invited to submit a full length paper to the Journal of Breath Research and this issue includes eight articles which describe the different applications of breath analysis. We thank all the authors for their valuable contribution and we trust that this collection will provide useful information and an update to this rapidly evolving field, giving an example of integration among scientists who address the same topic-breath analysis-from different and complementary perspectives, from basic to clinical research.

  16. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    PubMed

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  17. Prediction of heart transplant rejection with a breath test for markers of oxidative stress.

    PubMed

    Phillips, Michael; Boehmer, John P; Cataneo, Renee N; Cheema, Taseer; Eisen, Howard J; Fallon, John T; Fisher, Peter E; Gass, Alan; Greenberg, Joel; Kobashigawa, Jon; Mancini, Donna; Rayburn, Barry; Zucker, Mark J

    2004-12-15

    The Heart Allograft Rejection: Detection with Breath Alkanes in Low Levels study evaluated a breath test for oxidative stress in heart transplant recipients, and we report here a mathematical model predicting the probability of grade 3 rejection. The breath test divided the heart transplant recipients into 3 groups: positive for grade 3 rejection, negative for grade 3 rejection, and intermediate. The test was 100% sensitive for grade 3 heart transplant rejection when the p value was >/=0.98, and 100% specific when the p value was

  18. 46 CFR 197.450 - Breathing gas tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Breathing gas tests. 197.450 Section 197.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE OCCUPATIONAL SAFETY AND HEALTH STANDARDS GENERAL PROVISIONS Commercial Diving Operations Periodic Tests and Inspections of Diving Equipment § 197.450 Breathing gas tests. The diving...

  19. Reflux oesophagitis and Helicobacter pylori infection in elderly patients.

    PubMed Central

    Liston, R.; Pitt, M. A.; Banerjee, A. K.

    1996-01-01

    Helicobacter pylori is associated with gastritis, peptic ulcers and gastric malignancies. Little attention has been paid to the possibility that it may also have a role in the pathogenesis of reflux oesophagitis. This is especially true in elderly patients who have life-long infection and provide an ideal group to study the mucosal changes associated with the organism. The aim of this study was to determine if H pylori is associated with reflux oesophagitis in elderly patients. Consecutive gastroscopy patients were recruited. Multiple biopsies were taken from oesophagus, stomach, antrum and duodenum for histology and rapid urease tests. Patients also had IgG ELISA antibodies and 13C-urea breath tests performed. Patients with macroscopic or microscopic evidence of reflux oesophagitis were compared to patients with macroscopically normal upper gastrointestinal tracts and no microscopic evidence of reflux. A total of 114 patients were recruited, average age 78.9 years (+/- 5.4). There were 37 refluxers and 33 non-refluxers. We found no evidence for an association between the presence of H pylori and reflux oesophagitis in elderly patients. The high prevalence of H pylori in patients with reflux oesophagitis can be explained by the presence of incidental gastritis. PMID:8733530

  20. Quadruple therapy for eradication of Helicobacter pylori

    PubMed Central

    Ma, Hai-Jun; Wang, Jin-Liang

    2013-01-01

    AIM: To investigate quadruple therapy with rabeprazole, amoxicillin, levofloxacin and furazolidone for the eradication of Helicobacter pylori (H. pylori) infection. METHODS: A total of 147 patients were divided into the experimental treatment group (n = 78) and the standard triple treatment group (n = 69). The experimental treatment group received rabeprazole 20 mg, amoxicillin 1.0 g, levofloxacin 0.2 g and furazolidone 0.1 g, twice daily. The standard triple treatment group received omeprazole 20 mg, amoxicillin 1.0 g and clarithromycin 0.5 g, twice daily. RESULTS: One month after treatment, the 13C urea breath test was carried out to detect H. pylori. The eradication rate using per-protocol analysis was 94.3% in the experimental treatment group and 73% in the standard triple treatment group (P < 0.05), and using intention to test analysis, these figures were 86% and 67% in the two groups, respectively. Side effects were observed in 34 patients, and included mild dizziness, nausea, diarrhea and increased bowel movement. Eleven of the 34 patients needed no treatment for their side effects. CONCLUSION: Rabeprazole, amoxicillin, levofloxacin and furazolidone quadruple therapy is a safe method for the eradication of H. pylori with high efficacy and good tolerability. PMID:23429422

  1. [Effect of furazolidone quadruple regimen plus dental plaque removal procedures as rescue treatment of refractory Helicobacter pylori infection].

    PubMed

    Gao, Wen; Hu, Fu-lian; Wang, Xiao-min

    2011-03-29

    To observe the effect of furazolidone quadruple regimen plus dental plaque removal procedures as rescue treatment of refractory H. pylori infection. A total of 104 patients with H. pylori positive [(13)C-urea breath test (UBT) or rapid urease test positive] failing in previous treatment two or more were enrolled and divided into 2 groups. One group (n = 64) were given quadruple regimen [proton pump inhibitor (PPI) + bismuth + amoxicillin + furazolidone, 10 days] treatment and dental plaque removal treatment. And the others (n = 40) received only quadruple regimen treatment. The status of H. pylori was detected by (13)C-UBT at 4 weeks post-therapy and the eradication rates of two groups were compared. The eradication rate of quadruple regimen + dental treatment group was 85.9% (55/64) while that of the other group 72.5% (29/40) (P = 0.091). The PPI + bismuth quadruple regimen plus dental plaque removal procedures as rescue treatment may boost the eradication rate of refractory H. pylori infection patients. And the furazolidone quadruple therapy can be chosen for the treatment of refractory H. pylori infection. Oral H. pylori infection may play a role in the failure of H. pylori infection treatment.

  2. Stability of urea in solution and pharmaceutical preparations.

    PubMed

    Panyachariwat, Nattakan; Steckel, Hartwig

    2014-01-01

    The stability of urea in solution and pharmaceutical preparations was analyzed as a function of temperature (25°-60°C), pH (3.11-9.67), and initial urea concentration (2.5%-20%). This study was undertaken to (i) obtain more extensive, quantitative information relative to the degradation of urea in both aqueous and non-aqueous solutions and in pharmaceutical preparations, and (ii) test the effects of initial urea concentration, pH, buffer, and temperature values on urea degradation. The stability analysis shows that urea is more stable at the pH range of 4-8 and the stability of urea decreases by increase in temperature for all pH values. Within the experimental range of temperature and initial urea concentration values, the lowest urea degradation was found with lactate buffer pH 6.0. The urea decomposition rate in solution and pharmaceutical preparations shows the dependence of the initial urea concentrations. At higher initial urea concentrations, the rate of degradation is a decreasing function with time. This suggests that the reverse reaction is a factor in the degradation of concentrated urea solution. For non-aqueous solvents, isopropanol showed the best effort in retarding the decomposition of urea. Since the losses in urea is directly influenced by its stability at a given temperature and pH, the stability analysis of urea by the proposed model can be used to prevent the loss and optimize the operating condition for urea-containing pharmaceutical preparations.

  3. Tonsillar colonization is unlikely to play important role in Helicobacter pylori infection in children.

    PubMed

    Jelavic, Boris; Bevanda, Miljenko; Ostojic, Maja; Leventic, Miro; Vasilj, Mirjana; Knezevic, Ervin

    2007-04-01

    To determine (i) seroprevalence of Helicobacter pylori (HP) infection in children undergoing tonsillectomy, (ii) possible HP colonization on tonsils of children and its importance in HP transmission, and (iii) if four examined socio-economic factors are the risk factors for HP transmission and HP colonization on tonsils in children. Rapid urease test (RUT) of tonsils, and serologic blood tests for HP were performed in 77 children (aged 4-14 years) in Bosnia and Herzegovina (B-H), undergoing tonsillectomy. RUT positive tonsils were cultured for HP. RUT positive children were tested using (13)Carbon-urea breath test ((13)C-UBT). Information about socio-economic potential risk factors was obtained from the parents. Out of 139 pharyngeal and palatine tonsils, 17 palatine tonsils in 14 children were RUT positive and had negative HP culture. Eight children had positive both RUT and (13)C-UBT. There was no significant difference between children with hypertrophy and those with recurrent tonsillitis comparing their serologic tests results. There was no significant difference between seronegative (n=61) and seropositive (n=16) children comparing their age, sex, parental education level, owning a family courtyard, attending a children's collective, and owning a pet cat. The results in this prospective study do not support the notion that tonsils are an important reservoir for HP transmission in children in B-H. The examined socio-economic factors did not enhance HP seropositivity rate in children.

  4. (13)C-Breath testing in animals: theory, applications, and future directions.

    PubMed

    McCue, Marshall D; Welch, Kenneth C

    2016-04-01

    The carbon isotope values in the exhaled breath of an animal mirror the carbon isotope values of the metabolic fuels being oxidized. The measurement of stable carbon isotopes in carbon dioxide is called (13)C-breath testing and offers a minimally invasive method to study substrate oxidation in vivo. (13)C-breath testing has been broadly used to study human exercise, nutrition, and pathologies since the 1970s. Owing to reduced use of radioactive isotopes and the increased convenience and affordability of (13)C-analyzers, the past decade has witnessed a sharp increase in the use of breath testing throughout comparative physiology--especially to answer questions about how and when animals oxidize particular nutrients. Here, we review the practical aspects of (13)C-breath testing and identify the strengths and weaknesses of different methodological approaches including the use of natural abundance versus artificially-enriched (13)C tracers. We critically compare the information that can be obtained using different experimental protocols such as diet-switching versus fuel-switching. We also discuss several factors that should be considered when designing breath testing experiments including extrinsic versus intrinsic (13)C-labelling and different approaches to model nutrient oxidation. We use case studies to highlight the myriad applications of (13)C-breath testing in basic and clinical human studies as well as comparative studies of fuel use, energetics, and carbon turnover in multiple vertebrate and invertebrate groups. Lastly, we call for increased and rigorous use of (13)C-breath testing to explore a variety of new research areas and potentially answer long standing questions related to thermobiology, locomotion, and nutrition.

  5. Trimethylamine-N-oxide counteracts urea effects on rabbit muscle lactate dehydrogenase function: a test of the counteraction hypothesis.

    PubMed Central

    Baskakov, I; Wang, A; Bolen, D W

    1998-01-01

    Trimethylamine-N-oxide (TMAO) in the cells of sharks and rays is believed to counteract the deleterious effects of the high intracellular concentrations of urea in these animals. It has been hypothesized that TMAO has the generic ability to counteract the effects of urea on protein structure and function, regardless of whether that protein actually evolved in the presence of these two solutes. Rabbit muscle lactate dehydrogenase (LDH) did not evolve in the presence of either solute, and it is used here to test the validity of the counteraction hypothesis. With pyruvate as substrate, results show that its Km and the combined Km of pyruvate and NADH are increased by urea, decreased by TMAO, and in 1:1 and 2:1 mixtures of urea:TMAO the Km values are essentially equivalent to the Km values obtained in the absence of the two solutes. In contrast, values of k(cat) and the Km for NADH as a substrate are unperturbed by urea, TMAO, or urea:TMAO mixtures. All of these effects are consistent with TMAO counteraction of the effects of urea on LDH kinetic parameters, supporting the premise that counteraction is a property of the solvent system and is independent of the evolutionary history of the protein. PMID:9591690

  6. Association between Helicobacter Pylori Infection and Alopecia Areata: A Study in Iranian Population.

    PubMed

    Behrangi, Elham; Mansouri, Parvin; Agah, Shahram; Ebrahimi Daryani, Nasser; Mokhtare, Marjan; Azizi, Zahra; Ramezani Ghamsari, Mona; Rohani Nasab, Masoumeh; Azizian, Zahra

    2017-04-01

    BACKGROUND Alopecia areata is an immune mediated inflammatory hair loss, which occurs in all ethnic and age groups, and both sexes. However no significant etiology has been known for this disease. Helicobacter pylori (H. pylori) , is an organism colonized in gastric mucosa. This bacterium has been associated with certain extra-digestive dermatological conditions. The causal relationship between alopecia areata and H. pylori infection has been discussed in literature. Therefore, we conducted this study to evaluate the prevalence of H. pylori infection in patients with alopecia areata and assess the risk of this infection in patients with this disease in order to determine its potential roles in the physiopathology of this disease. METHODS Between 2014 and 2015, we prospectively studied 81 patients with alopecia areata and 81 healthy volunteers with similar age and sex. Patients without any history of H. pylori infection were included in the study and underwent urease breath test. All results were analyzed using SPSS software (version 21.0) and p value<0.05 was considered as statistically significant. RESULTS 81 patients and 81 controls with the mean age of 34.9±11.6 and 38.2±13.4 years were studied (p=0.097). 48 (59.3%) and 45 (55.6%) individuals were male, in cases and control groups respectively (p =0.634). The result of urea breath test (UBT) was positive in 43 (53.1%) patients in cases and 27 (33.3%) individuals in control group, which was significantly different (p =0.011). The risk of H. pylori infection in alopecia areata was 2.263 (95% CI: 1.199-4.273). CONCLUSION The results of our study showed significant difference between H. pylori infection in individuals with and without alopecia areata, which shows that H. pylori contamination may be effective in physiopathology of alopecia areata. Therefore these results should be tested in large multivariable cohorts and controlled trials to reach more accurate evidence in the future and to generalize this idea to larger population.

  7. Data Mining Techniques Applied to Hydrogen Lactose Breath Test.

    PubMed

    Rubio-Escudero, Cristina; Valverde-Fernández, Justo; Nepomuceno-Chamorro, Isabel; Pontes-Balanza, Beatriz; Hernández-Mendoza, Yoedusvany; Rodríguez-Herrera, Alfonso

    2017-01-01

    Analyze a set of data of hydrogen breath tests by use of data mining tools. Identify new patterns of H2 production. Hydrogen breath tests data sets as well as k-means clustering as the data mining technique to a dataset of 2571 patients. Six different patterns have been extracted upon analysis of the hydrogen breath test data. We have also shown the relevance of each of the samples taken throughout the test. Analysis of the hydrogen breath test data sets using data mining techniques has identified new patterns of hydrogen generation upon lactose absorption. We can see the potential of application of data mining techniques to clinical data sets. These results offer promising data for future research on the relations between gut microbiota produced hydrogen and its link to clinical symptoms.

  8. Salivary creatinine and urea analysis in patients with chronic kidney disease: a case control study.

    PubMed

    Lasisi, Taye Jemilat; Raji, Yemi Raheem; Salako, Babatunde Lawal

    2016-01-16

    Many metabolic changes develop in patients with chronic kidney disease which often necessitate frequent biochemical analysis of blood. Saliva analysis as an alternative to blood has many advantages. The aims of this study were to evaluate levels of salivary creatinine and urea in patients with chronic kidney disease in comparison to healthy individuals; to determine correlation between salivary creatinine/urea and blood creatinine/urea and to evaluate the diagnostic potential of saliva. A case control study, involving 50 patients with late stage chronic kidney disease and 49 healthy individuals as control. Blood and saliva samples were analyzed for urea and creatinine levels. Data are presented as median with interquartile range and compared using Independent Samples Mann Whitney U test. Correlation between plasma and salivary creatinine as well as urea was determined using Spearman's correlation test. Receiver operating characteristics (ROC) analysis was done to determine the diagnostic ability of salivary creatinine and urea and cut-off values were established. Median salivary creatinine levels were 2.60 mg/dl and 0.20 mg/dl while median salivary urea levels were 92.00 mg/dl and 20.50 mg/dl in patients with chronic kidney disease and controls respectively. Salivary levels of creatinine and urea were significantly elevated in chronic kidney disease patients (p < 0.001). In addition, there was positive correlation between blood and salivary creatinine as well as urea levels. Total areas under the curve for salivary creatinine and urea were 0.97 and 0.89 respectively. Cut-off values for salivary creatinine and urea were 0.55 mg/dl and 27.50 mg/dl respectively which gave sensitivity and specificity of 94 % and 85 % for creatinine; as well as 86 % and 93 % for urea. Findings of this study suggest that analysis of salivary creatinine and urea in patients with chronic kidney disease reflects their levels in blood. Hence, salivary creatinine and urea could be used as diagnostic biomarkers of chronic kidney disease.

  9. A metabolic simulator for unmanned testing of breathing apparatuses in hyperbaric conditions.

    PubMed

    Frånberg, Oskar; Loncar, Mario; Larsson, Åke; Ornhagen, Hans; Gennser, Mikael

    2014-11-01

    A major part of testing of rebreather apparatuses for underwater diving focuses on the oxygen dosage system. A metabolic simulator for testing breathing apparatuses was built and evaluated. Oxygen consumption was achieved through catalytic combustion of propene. With an admixture of carbon dioxide in the propene fuel, the system allowed the respiratory exchange ratio to be set freely within human variability and also made it possible to increase test pressures above the condensation pressure of propene. The system was tested by breathing ambient air in a pressure chamber with oxygen uptake (Vo₂) ranging from 1-4 L · min(-1), tidal volume (VT) from 1-3 L, breathing frequency (f) of 20 and 25 breaths/min, and chamber pressures from 100 to 670 kPa. The measured end-tidal oxygen concentration (Fo₂) was compared to calculated end-tidal Fo₂. The largest average difference in end-tidal Fo₂during atmospheric pressure conditions was 0.63%-points with a 0.28%-point average difference during the whole test. During hyperbaric conditions with pressures ranging from 100 to 670 kPa, the largest average difference in Fo₂was 1.68%-points seen during compression from 100 kPa to 400 kPa and the average difference in Fo₂during the whole test was 0.29%-points. In combination with a breathing simulator simulating tidal breathing, the system can be used for dynamic continuous testing of breathing equipment with changes in VT, f, Vo2, and pressure.

  10. 49 CFR 40.267 - What problems always cause an alcohol test to be cancelled?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... breath tube ASD). (4) The breath tube ASD is tested with an analyzer which has not been pre-calibrated... the case of a screening test conducted on a saliva ASD or a breath tube ASD: (1) The STT or BAT reads... § 40.245(a)(8) for the saliva ASD and § 40.245(b)(8) for the breath tube ASD). (2) The saliva ASD does...

  11. 49 CFR 40.267 - What problems always cause an alcohol test to be cancelled?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... breath tube ASD). (4) The breath tube ASD is tested with an analyzer which has not been pre-calibrated... the case of a screening test conducted on a saliva ASD or a breath tube ASD: (1) The STT or BAT reads... § 40.245(a)(8) for the saliva ASD and § 40.245(b)(8) for the breath tube ASD). (2) The saliva ASD does...

  12. 49 CFR 40.267 - What problems always cause an alcohol test to be cancelled?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... breath tube ASD). (4) The breath tube ASD is tested with an analyzer which has not been pre-calibrated... the case of a screening test conducted on a saliva ASD or a breath tube ASD: (1) The STT or BAT reads... § 40.245(a)(8) for the saliva ASD and § 40.245(b)(8) for the breath tube ASD). (2) The saliva ASD does...

  13. Operation and testing of Mark 10 Mod 3 underwater breathing apparatus

    NASA Technical Reports Server (NTRS)

    Milwee, W. I., Jr.

    1972-01-01

    Performance tests on a closed circuit, mixed gas underwater breathing apparatus are reported. The equipment is designed to provide a minimum diving duration of four hours at 1500 ft below sea surface; it senses oxygen partial pressure in the breathing gas mix and controls oxygen content of the breathing gas within narrow limits about a preset value. The breathing circuit subsystem provides respirable gas to the diver and removes carbon dioxide and moisture from the expired gas. Test results indicate undesirable variations in oxygen partial pressure with oxygen addition and insufficient carbon dioxide absorption.

  14. On the influence of the mixture of denaturants on protein structure stability: A molecular dynamics study

    NASA Astrophysics Data System (ADS)

    Shao, Qiang; Wang, Jinan; Zhu, Weiliang

    2014-09-01

    Mixtures of osmolytes and/or inorganic salts are present in the cell. Therefore, the understanding of the interplay of mixed osmolyte molecules and inorganic salts and their combined effects on protein structure is of fundamental importance. A novel test is presented to investigate the combined effects of urea and a chaotropic inorganic salt, potassium iodide (KI), on protein structure by using molecular dynamics simulation. It is found that the coexistence of KI and urea does not affect their respective distribution in solution. The solvation of KI salt in urea solution makes the electrostatic interactions of urea more favorable, promoting the hydrogen bonding between urea (and water) to protein backbone. The interactions from K+ and hydrogen bonding from urea and water to protein backbone work as the driving force for protein denaturation. The collaborative behavior of urea and KI salt thus enhances the denaturing ability of urea and KI mixed solution.

  15. Unique mitochondrial localization of arginase 1 and 2 in hepatocytes of air-breathing walking catfish, Clarias batrachus and their differential expression patterns under hyper-ammonia stress.

    PubMed

    Banerjee, Bodhisattwa; Koner, Debaprasad; Lal, Priyanka; Saha, Nirmalendu

    2017-07-30

    Arginase (ARG) catalyzes the final step of ornithine-urea cycle (OUC) leading to a conversion of L-arginine to L-ornithine and urea. Several isoforms of ARG have been reported in vertebrates, out of which the two predominant isoforms are the cytosolic ARG1 and the mitochondrial ARG2. The air-breathing walking catfish (Clarias batrachus) is frequently being challenged by different environmental insults such as hyper-ammonia, dehydration and osmotic stresses in their natural habitats throughout the year. The present study investigated the active presence of ARG1 and ARG2 isoforms in hepatocytes along with unique localization of both the isoforms inside the mitochondria, and also their specific expression patterns under hyper-ammonia stress (5mM NH 4 Cl) in isolated hepatocytes of walking catfish. Initially, full length sequences of both arg1 and arg2 genes were obtained by RACE-PCR. Studies on molecular characterization demonstrated the presence of all the conserved amino acids required for stability and activity of binuclear metal center in both the isoforms. Phylogenetic analysis of the amino acid sequences of ARG isoforms showed a differentiation of the ARG1 and ARG2 into two distinct clusters with their respective isoforms from other species. Most interestingly, both the isoforms of ARG in hepatocytes were found to be localized inside the mitochondria as evidenced by the presence of mitochondrial target peptide (mTP) in N-terminal of the derived amino acid sequences, and exclusive localization of ARG activity in the mitochondrial fraction. This was additionally confirmed by Western blot analysis of ARGs in mitochondrial and cytosolic fractions, and by immunocytochemical analysis in isolated hepatocytes. Although the possible reasons associated with the presence of both the isoforms of ARGs inside the mitochondria is not clearly understood, perhaps this mitochondrial localization of ARG is functionally advantageous in this catfish for the synthesis of N-acetyl-l-glutamate, the allosteric regulator for the first OUC enzyme, the carbamoyl phosphate synthetase III, and for supplying ornithine required for citrulline synthesis intramitochondrially. Furthermore, the ammonia stress, due to exposure to high external ammonia, led to greater synthesis of urea-N probably as a consequence of induction of ureogenesis, as evidenced by a larger accumulation of urea-N in hepatocytes and higher secretion in culture media parallel to the increased concentration of ammonia-N in hepatocytes. Ammonia stress also led to specific coordinated patterns of induction of both the arg genes in isolated hepatocytes of walking catfish. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Does smoking abstinence influence distress tolerance? An experimental study comparing the response to a breath-holding test of smokers under tobacco withdrawal and under nicotine replacement therapy.

    PubMed

    Cosci, Fiammetta; Anna Aldi, Giulia; Nardi, Antonio Egidio

    2015-09-30

    Distress tolerance has been operationalized as task persistence in stressful behavioral laboratory tasks. According to the distress tolerance perspective, how an individual responds to discomfort/distress predicts early smoking lapses. This theory seems weakly supported by experimental studies since they are limited in number, show inconsistent results, do not include control conditions. We tested the response to a stressful task in smokers under abstinence and under no abstinence to verify if tobacco abstinence reduces task persistence, thus distress tolerance. A placebo-controlled, double-blind, randomized, cross-over design was used. Twenty smokers underwent a breath holding test after the administration of nicotine on one test day and a placebo on another test day. Physiological and psychological variables were assessed at baseline and directly before and after each challenge. Abstinence induced a statistically significant shorter breath holding duration relative to the nicotine condition. No different response to the breath holding test was observed when nicotine and placebo conditions were compared. No response to the breath holding test was found when pre- and post-test values of heart rate, blood pressure, Visual Analogue Scale for fear or discomfort were compared. In brief, tobacco abstinence reduces breath holding duration but breath holding test does not influence discomfort. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  18. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  19. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  20. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  1. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  2. Deposits from Creams Containing 20% (w/w) Urea and Suppression of Crystallization (Part 2): Novel Analytical Methods of Urea Accumulated in the Stratum Corneum by Tape stripping and Colorimetry.

    PubMed

    Goto, Norio; Morita, Yutaka; Terada, Katsuhide

    2016-01-01

    The transfer of urea from a urea formulation to the stratum corneum varies with the formulation base and form, and impacts the formulation's therapeutic effect. Consequently, determining the amount of urea transferred is essential for developing efficient formulations. This study assessed a simple method for measuring the amount of urea accumulated in the stratum corneum. Conventional methods rely on labeling urea used in the formulation with radiocarbon ((14)C) or other radioactive isotopes (RIs), retrieving the transferred urea from the stratum corneum by tape stripping, then quantitating the urea. The handling and use of RIs, however, is subject to legal regulation and can only be performed in sanctioned facilities, so methods employing RIs are neither simple nor convenient. We therefore developed a non-radiolabel method "tape stripping-colorimetry (T-C)" that combines tape stripping with colorimetry (urease-glutamate dehydrogenase (GLDH)) for the quantitative measurement of urea. Urea in the stratum corneum is collected by tape stripping and measured using urease-GLDH, which is commonly used to measure urea nitrogen in blood tests. The results indicate that accurate urea measurement by the T-C method requires the application of 1400 mg (on hairless rats) of a 20% urea solution on a 50 cm(2) (5×10 cm) area. Further, we determined the amount of urea accumulated in the stratum corneum using formulations with different urea concentrations, and the time course of urea accumulation from formulations differing in the rate of urea crystallization. We demonstrate that the T-C method is simple and convenient, with no need for (14)C or other RIs.

  3. Variability in the blood/breath alcohol ratio and implications for evidentiary purposes.

    PubMed

    Jaffe, Dena H; Siman-Tov, Maya; Gopher, Asher; Peleg, Kobi

    2013-09-01

    The breath analyzer is an indispensable tool for identifying alcohol levels among drivers. While numerous studies have shown high correlations between blood and breath alcohol concentrations, most are limited by the study design. This study seeks to assess this relationship by minimizing potential measurement bias, document time from alcohol consumption to testing, and adjusting for potential confounders. A blinded study was performed using conditions closely resembling those in the field. The Draeger 7110 MKIII IL breath analyzer was used to assess breath alcohol concentrations (BrAC). Participants were 61 healthy volunteers aged 21-37 years with body mass index ≤30 and no history of alcoholism. A total of 242 valid blood/breath tests were performed in four test sets. The study results showed a high correlation coefficient between BrAC and blood alcohol concentration (BAC) levels (r = 0.983) with high sensitivity (97%) and specificity (93%). This strong association between the breath analyzer and BAC persisted even after adjustment for various stages of alcohol absorption. These results illustrate the high diagnostic sensitivity of the breath analyzer in field-tested conditions. © 2013 American Academy of Forensic Sciences.

  4. Predictive values of semi-quantitative procalcitonin test and common biomarkers for the clinical outcomes of community-acquired pneumonia.

    PubMed

    Ugajin, Motoi; Yamaki, Kenichi; Hirasawa, Natsuko; Yagi, Takeo

    2014-04-01

    The semi-quantitative serum procalcitonin test (Brahms PCT-Q) is available conveniently in clinical practice. However, there are few data on the relationship between results for this semi-quantitative procalcitonin test and clinical outcomes of community-acquired pneumonia (CAP). We investigated the usefulness of this procalcitonin test for predicting the clinical outcomes of CAP in comparison with severity scoring systems and the blood urea nitrogen/serum albumin (B/A) ratio, which has been reported to be a simple but reliable prognostic indicator in our prior CAP study. This retrospective study included data from subjects who were hospitalized for CAP from August 2010 through October 2012 and who were administered the semi-quantitative serum procalcitonin test on admission. The demographic characteristics; laboratory biomarkers; microbiological test results; Pneumonia Severity Index scores; confusion, urea nitrogen, breathing frequency, blood pressure, ≥ 65 years of age (CURB-65) scale scores; and age, dehydration, respiratory failure, orientation disturbance, pressure (A-DROP) scale scores on hospital admission were retrieved from their medical charts. The outcomes were mortality within 28 days of hospital admission and the need for intensive care. Of the 213 subjects with CAP who were enrolled in the study, 20 died within 28 days of hospital admission, and 32 required intensive care. Mortality did not differ significantly among subjects with different semi-quantitative serum procalcitonin levels; however, subjects with serum procalcitonin levels ≥ 10.0 ng/mL were more likely to require intensive care than those with lower levels (P < .001). The elevation of semi-quantitative serum procalcitonin levels was more frequently observed in subjects with proven etiology, especially pneumococcal pneumonia. Using the receiver operating characteristic curves for mortality, the area under the curve was 0.86 for Pneumonia Severity Index class, 0.81 for B/A ratio, 0.81 for A-DROP, 0.80 for CURB-65, and 0.57 for semi-quantitative procalcitonin test. The semi-quantitative serum procalcitonin level on hospital admission was less predictive of mortality from CAP compared with the B/A ratio. However, the subjects with serum procalcitonin levels ≥ 10.0 ng/mL were more likely to require intensive care than those with lower levels.

  5. Police custody following drink-driving: a prospective study.

    PubMed

    Lepresle, Aude; Mahindhoratep, Tiao Saysouda; Chiadmi, Fouad; Schlatter, Joël; Boraud, Cyril; Chariot, Patrick

    2012-11-01

    Drink-driving is a crime and traffic offences are a common cause of detention in police custody. Legal assessment of alcohol intoxication is based on breath or blood testing. We hypothesize that refusal of breath alcohol testing or inability to perform it can correspond to singular medical characteristics of the detainee, possibly assaulted or injured during the arrest. Our objective was to determine medical characteristics of detainees held in custody for drink-driving. Prospective monocentric study (April-October, 2010) of drink-drive arrestees. Controls were persons aged over 18 detained for other reasons than drink-driving. Data collected concerned persons' characteristics and reported assaults or observed injuries. 223 drivers were tested positive for breath alcohol level and 55 suspected drink-drivers refused or were not able to complete breath test. 2212 consecutively examined persons served as controls. Drink-drive arrestees requested medical examination more rarely (18% and 7%, vs. 43%, P<0.0001) and drivers tested positive for breath alcohol were more frequently alcohol abusers (25% vs. 14%, P<0.0001) than controls. Drivers who did not complete breath test more often reported assaults than those tested positive for breath alcohol (22% vs. 8%, P=0.007). They had more frequent traumatic injuries than those tested positive and than controls (29% vs. 11% and 17%, P=0.003 and 0.02). Only 1% of drink drivers were unfit for detention after medical examination. Physicians need to give attentive care to detained drink-drivers. Special attention should be paid to drink-drivers who refused or were not able to complete breath alcohol measurement. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. 49 CFR 219.301 - Testing for reasonable cause.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... breath or body fluid testing, or both, to determine compliance with §§ 219.101 and 219.102 or a railroad... an employee that is required when an employee is required to provide a breath or body fluid specimen... breath testing. In addition to reasonable suspicion as described in § 219.300, the following...

  7. 49 CFR 219.301 - Testing for reasonable cause.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... breath or body fluid testing, or both, to determine compliance with §§ 219.101 and 219.102 or a railroad... an employee that is required when an employee is required to provide a breath or body fluid specimen... breath testing. In addition to reasonable suspicion as described in § 219.300, the following...

  8. Urea enhances the photodynamic efficiency of methylene blue.

    PubMed

    Nuñez, Silvia C; Yoshimura, Tania M; Ribeiro, Martha S; Junqueira, Helena C; Maciel, Cleiton; Coutinho-Neto, Maurício D; Baptista, Maurício S

    2015-09-01

    Methylene blue (MB) is a well-known photosensitizer used mostly for antimicrobial photodynamic therapy (APDT). MB tends to aggregate, interfering negatively with its singlet oxygen generation, because MB aggregates lean towards electron transfer reactions, instead of energy transfer with oxygen. In order to avoid MB aggregation we tested the effect of urea, which destabilizes solute-solute interactions. The antimicrobial efficiency of MB (30 μM) either in water or in 2M aqueous urea solution was tested against a fungus (Candida albicans). Samples were kept in the dark and irradiation was performed with a light emitting diode (λ = 645 nm). Without urea, 9 min of irradiation was needed to achieve complete microbial eradication. In urea solution, complete eradication was obtained with 6 min illumination (light energy of 14.4 J). The higher efficiency of MB/urea solution was correlated with a smaller concentration of dimers, even in the presence of the microorganisms. Monomer to dimer concentration ratios were extracted from the absorption spectra of MB solutions measured as a function of MB concentration at different temperatures and at different concentrations of sodium chloride and urea. Dimerization equilibrium decreased by 3 and 6 times in 1 and 2M urea, respectively, and increased by a factor of 6 in 1M sodium chloride. The destabilization of aggregates by urea seems to be applied to other photosensitizers, since urea also destabilized aggregation of Meso-tetra(4-n-methyl-pyridyl)porphyrin, which is a positively charged porphyrin. We showed that urea destabilizes MB aggregates mainly by causing a decrease in the enthalpic gain of dimerization, which was exactly the opposite of the effect of sodium chloride. In order to understand this phenomenon at the molecular level, we computed the free energy for the dimer association process (ΔG(dimer)) in aqueous solution as well as its enthalpic component in aqueous and in aqueous/urea solutions by molecular dynamics simulations. In 2M-urea solution the atomistic picture revealed a preferential solvation of MB by urea compared with MB dimers while changes in ΔH(dimer) values demonstrated a clear shift favoring MB monomers. Therefore, MB monomers are more stable in urea solutions, which have significantly better photophysics and higher antimicrobial activity. This information can be of use for dental and medical professionals that are using MB based APDT protocols. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Use of 16S rRNA Sequencing for Identification of Actinobacillus ureae Isolated from a Cerebrospinal Fluid Sample

    PubMed Central

    Whitelaw, A. C.; Shankland, I. M.; Elisha, B. G.

    2002-01-01

    Actinobacillus ureae, previously Pasteurella ureae, has on rare occasions been described as a cause of human infection. Owing to its rarity, it may not be easily identified in clinical microbiology laboratories by standard tests. This report describes a patient with acute bacterial meningitis due to A. ureae. The identity of the isolate was determined by means of DNA sequence analysis of a portion of the 16S rRNA gene. PMID:11825992

  10. Application of LaserBreath-001 for breath acetone measurement in subjects with diabetes mellitus

    NASA Astrophysics Data System (ADS)

    Wang, Zhennan; Sun, Meixiu; Chen, Zhuying; Zhao, Xiaomeng; Li, Yingxin; Wang, Chuji

    2016-11-01

    Breath acetone is a promising biomarker of diabetes mellitus. With an integrated standalone, on-site cavity ringdown breath acetone analyzer, LaserBreath-001, we tested breath samples from 23 type 1 diabetic (T1D) patients, 312 type 2 diabetic (T2D) patients, 52 healthy subjects. In the cross-sectional studies, the obtained breath acetone concentrations were higher in the diabetic subjects compared with those in the control group. No correlation between breath acetone and simultaneous BG was observed in the T1D, T2D, and healthy subjects. A moderate positive correlation between the mean individual breath acetone concentrations and the mean individual BG levels was observed in the 20 T1D patients without ketoacidosis. In a longitudinal study, the breath acetone concentrations in a T1D patient with ketoacidosis decreased significantly and remained stable during the 5-day hospitalization. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone concentrations, fast (<1 min) and on site breath acetone measurement can be used for diabetic screening and management under a specifically controlled condition.

  11. Can Blood Gas and Acid-Base Parameters at Maximal 200 Meters Front Crawl Swimming be Different Between Former Competitive and Recreational Swimmers?

    PubMed Central

    Kapus, Jernej; Usaj, Anton; Strumbelj, Boro; Kapus, Venceslav

    2008-01-01

    The aim of the present study was to ascertain whether maximal 200 m front crawl swimming strategies and breathing patterns influenced blood gas and acid-base parameters in a manner which gives advantage to former competitive swimmers in comparison with their recreational colleagues. Twelve former competitive male swimmers (the CS group) and nine recreational male swimmers (the RS group) performed a maximal 200 m front crawl swimming with self- selected breathing pattern. Stroke rate (SR) and breathing frequency (BF) were measured during the swimming test. Measures also included blood lactate concentration ([LA]) and parameters of blood acid-base status before and during the first minute after the swimming test. The CS group swam faster then the RS group. Both groups have similar and steady SR throughout the swimming test. This was not matched by similar BF in the CS group but matched it very well in the RS group (r = 0.89). At the beginning of swimming test the CS group had low BF, but they increased it throughout the swimming test. The BF at the RS group remained constant with only mirror variations throughout the swimming test. Such difference in velocity and breathing resulted in maintaining of blood Po2 from hypoxia and Pco2 from hypercapnia. This was similar in both groups. [LA] increased faster in the CS group than in the RS group. On the contrary, the rate of pH decrease remained similar in both groups. The former competitive swimmers showed three possible advantages in comparison to recreational swimmers during maximal 200 m front crawl swimming: a more dynamic and precise regulation of breathing, more powerful bicarbonate buffering system and better synchronization between breathing needs and breathing response during swimming. Key pointsTraining programs for competitive swimmers should promote adaptations to maximal efforts.Those adaptations should include high and maximal intensity swims with controlled breathing frequency (taking breath every fourth, fifth, sixth or eighth stroke cycle for front crawl swimming).Such training will improve breathing regulation in order to impose a better synchronization between breathing needs and breathing response during maximal swimming. PMID:24150142

  12. Short mucin 6 alleles are associated with H pylori infection

    PubMed Central

    Nguyen, Thai V; Janssen, Marcel JR; Gritters, Paulien; te Morsche, René HM; Drenth, Joost PH; van Asten, Henri; Laheij, Robert JF; Jansen, Jan BMJ

    2006-01-01

    AIM: To investigate the relationship between mucin 6 (MUC6) VNTR length and H pylori infection. METHODS: Blood samples were collected from patients visiting the Can Tho General Hospital for upper gastrointestinal endoscopy. DNA was isolated from whole blood, the repeated section was cut out using a restriction enzyme (PvuII) and the length of the allele fragments was determined by Southern blotting. H pylori infection was diagnosed by 14C urea breath test. For analysis, MUC6 allele fragment length was dichotomized as being either long (> 13.5 kbp) or short (≤ 13.5 kbp) and patients were classified according to genotype [long-long (LL), long-short (LS), short-short (SS)]. RESULTS: 160 patients were studied (mean age 43 years, 36% were males, 58% H pylori positive). MUC6 PvuII-restricted allele fragment lengths ranged from 7 to 19 kbp. Of the patients with the LL, LS, SS MUC6 genotype, 43% (24/56), 57% (25/58) and 76% (11/46) were infected with H pylori, respectively (P = 0.003). CONCLUSION: Short MUC6 alleles are associated with H pylori infection. PMID:17009402

  13. Short mucin 6 alleles are associated with H pylori infection.

    PubMed

    Nguyen, Thai V; Janssen, Marcel; Gritters, Paulien; te Morsche, René H M; Drenth, Joost P H; van Asten, Henri; Laheij, Robert J F; Jansen, Jan B M J

    2006-10-07

    To investigate the relationship between mucin 6 (MUC6) VNTR length and H pylori infection. Blood samples were collected from patients visiting the Can Tho General Hospital for upper gastrointestinal endoscopy. DNA was isolated from whole blood, the repeated section was cut out using a restriction enzyme (Pvu II) and the length of the allele fragments was determined by Southern blotting. H pylori infection was diagnosed by (14)C urea breath test. For analysis, MUC6 allele fragment length was dichotomized as being either long (> 13.5 kbp) or short (< or = 13.5 kbp) and patients were classified according to genotype [long-long (LL), long-short (LS), short-short (SS)]. 160 patients were studied (mean age 43 years, 36% were males, 58% H pylori positive). MUC6 Pvu II-restricted allele fragment lengths ranged from 7 to 19 kbp. Of the patients with the LL, LS, SS MUC6 genotype, 43% (24/56), 57% (25/58) and 76% (11/46) were infected with H pylori, respectively (P = 0.003). Short MUC6 alleles are associated with H pylori infection.

  14. An acetone breath analyzer using cavity ringdown spectroscopy: an initial test with human subjects under various situations

    NASA Astrophysics Data System (ADS)

    Wang, Chuji; Surampudi, Anand B.

    2008-10-01

    We have developed a portable breath acetone analyzer using cavity ringdown spectroscopy (CRDS). The instrument was initially tested by measuring the absorbance of breath gases at a single wavelength (266 nm) from 32 human subjects under various conditions. A background subtraction method, implemented to obtain absorbance differences, from which an upper limit of breath acetone concentration was obtained, is described. The upper limits of breath acetone concentration in the four Type 1 diabetes (T1D) subjects, tested after a 14 h overnight fast, range from 0.80 to 3.97 parts per million by volume (ppmv), higher than the mean acetone concentration (0.49 ppmv) in non-diabetic healthy breath reported in the literature. The preliminary results show that the instrument can tell distinctive differences between the breath from individuals who are healthy and those with T1D. On-line monitoring of breath gases in healthy people post-exercise, post-meals and post-alcohol-consumption was also conducted. This exploratory study demonstrates the first CRDS-based acetone breath analyzer and its potential application for point-of-care, non-invasive, diabetic monitoring.

  15. When Breathing Interferes with Cognition: Experimental Inspiratory Loading Alters Timed Up-and-Go Test in Normal Humans.

    PubMed

    Nierat, Marie-Cécile; Demiri, Suela; Dupuis-Lozeron, Elise; Allali, Gilles; Morélot-Panzini, Capucine; Similowski, Thomas; Adler, Dan

    2016-01-01

    Human breathing stems from automatic brainstem neural processes. It can also be operated by cortico-subcortical networks, especially when breathing becomes uncomfortable because of external or internal inspiratory loads. How the "irruption of breathing into consciousness" interacts with cognition remains unclear, but a case report in a patient with defective automatic breathing (Ondine's curse syndrome) has shown that there was a cognitive cost of breathing when the respiratory cortical networks were engaged. In a pilot study of putative breathing-cognition interactions, the present study relied on a randomized design to test the hypothesis that experimentally loaded breathing in 28 young healthy subjects would have a negative impact on cognition as tested by "timed up-and-go" test (TUG) and its imagery version (iTUG). Progressive inspiratory threshold loading resulted in slower TUG and iTUG performance. Participants consistently imagined themselves faster than they actually were. However, progressive inspiratory loading slowed iTUG more than TUG, a finding that is unexpected with regard to the known effects of dual tasking on TUG and iTUG (slower TUG but stable iTUG). Insofar as the cortical networks engaged in response to inspiratory loading are also activated during complex locomotor tasks requiring cognitive inputs, we infer that competition for cortical resources may account for the breathing-cognition interference that is evidenced here.

  16. [Separation of gamma linolenic acid from evening primrose oil with urea inclusion--orthogonal experiment of optimizing technological parameters and observation of urea inclusion compound I].

    PubMed

    Wang, Hua; Ling, Man; Xue, Gang; Liu, Fengxia; Guo, Shuxian

    2010-05-01

    The influence on the urea inclusion compound under different conditions (allocated proportion, time of inclusion, temperature of inclusion) were studied through the orthogonal test, and theoretical reference of urea inclusion process for further optimization wound be offered. The orthogonal experiment was adopted, and microscope was used to observe the shape, aperture size of the urea inclusion compound under different technological parameters, the GC was employed to inspect the purity of GLA. The results indicated that the ratio of fatty acids and urea, inclusion of temperature, time of inclusion had great effect on urea inclusion compound. The three factors and its interactions significantly affected the purity of GLA. The results also showed that the best process was that the ratio of fatty acids and urea was 1 : 3, temperature of inclusion was--15 degrees C, time of inclusion was 24 h. Under the best condition, the purity of GLA reach up to 95.575 9%; and it is feasible to observe the shape and the amount of the urea inclusion compound to reflect and guide the urea inclusion technology.

  17. Clinical applications of breath testing

    PubMed Central

    Paschke, Kelly M; Mashir, Alquam

    2010-01-01

    Breath testing has the potential to benefit the medical field as a cost-effective, non-invasive diagnostic tool for diseases of the lung and beyond. With growing evidence of clinical worth, standardization of methods, and new sensor and detection technologies the stage is set for breath testing to gain considerable attention and wider application in upcoming years. PMID:21173863

  18. Breath measurement instrumentation as alcohol safety interlock systems

    DOT National Transportation Integrated Search

    1974-09-01

    This report describes the results of field tests of in-car instruments which measure alcohol on the driver's breath and prevent him from operating his vehicle if intoxicated. Two types of breath alcohol sensors were used for these tests; a fuel-cell ...

  19. Updating prognosis of cirrhosis by Cox's regression model using Child-Pugh score and aminopyrine breath test as time-dependent covariates.

    PubMed

    Merkel, C; Morabito, A; Sacerdoti, D; Bolognesi, M; Angeli, P; Gatta, A

    1998-06-01

    The determination of aminopyrine breath test on entry into the study was recently shown to improve the accuracy of prediction of death based on the Child-Pugh classification, but the possible usefulness of serial determinations of both parameters has not been assessed. In the present study, we aimed at evaluating whether serial determinations of aminopyrine breath test and Child-Pugh score improve prognostic accuracy in patients with cirrhosis, compared with determinations obtained only on admission. In 74 patients with liver cirrhosis aminopyrine breath test and Child-Pugh score were obtained upon entry into the study. Patients were followed with sequential aminopyrine breath tests and assessments of the Child-Pugh score every 4-6 months. A total number of 232 determinations were obtained. During follow-up 45 patients died, on average after 12 months of follow-up. Child-Pugh score improved in the beginning of follow-up, and then remained fairly constant; aminopyrine breath test showed no improvement in the beginning of follow-up, but rather a slowly progressive decline. In patients who died, both the Child-Pugh score and the metabolism of aminopyrine were significantly more impaired in the last year preceding death (p < 0.05). Applying Cox's regression model with time-dependent covariates, Child-Pugh score and aminopyrine breath test were independent significant predictors of survival. The model with time-dependent covariates explained the observed survival much better than the model with time-fixed covariates (chi-sq. explained by regression = 31.45 vs 11.97; d.f. = 2; p = 0.0000001 vs 0.003). These data suggest that serial determinations of Child-Pugh score and aminopyrine breath test can be used to efficiently update prognosis of cirrhosis.

  20. Helicobacter pylori diagnostic tests in children: review of the literature from 1999 to 2009.

    PubMed

    Guarner, Jeannette; Kalach, Nicolas; Elitsur, Yoram; Koletzko, Sibylle

    2010-01-01

    The array of tests that can be used for diagnosis of Helicobacter pylori infection is large, and it can be confusing to define which test to use particularly in children where results may not be comparable to those obtained in adult patients. Using PubMed, we reviewed the English literature from January 1999 to May 2009 to identify articles that determined sensitivity and specificity of H. pylori invasive and non-invasive diagnostic tests in children. We excluded articles that presented a review of the literature, abstracts, case reports, or series where children's results could not be separated from adult populations. Of the tissue based methods, rapid urease tests have better sensitivity than histology to detect presence of H. pylori; however, histology can detect the pathology associated with disease including gastritis, intestinal metaplasia, and other conditions that could be the cause of the child's symptoms. Culture of gastric tissues or stool has 100% specificity but sensitivity is low. Of the serologic tests, immunoblot has the best sensitivity. The urea breath tests have >75% sensitivity for detection of H. pylori before and after treatment. Immunoassays in stool using monoclonal antibodies have >95% sensitivity for detection of H. pylori before and after treatment. PCR testing can be performed in tissue and stool samples and can detect genes associated to antibiotic resistance. In summary, the current commercial non-invasive tests have adequate sensitivity and specificity for detecting the presence of H. pylori; however, endoscopy with histopathology is the only method that can detect H. pylori and lesions associated with the infection.

  1. The effect of simulated air conditions on N95 filtering facepiece respirators performance.

    PubMed

    Ramirez, Joel A; O'Shaughnessy, Patrick T

    2016-07-01

    The objective of this study was to determine the effect of several simulated air environmental conditions on the particle penetration and the breathing resistance of two N95 filtering facepiece respirator (FFR) models. The particle penetration and breathing resistance of the respirators were evaluated in a test system developed to mimic inhalation and exhalation breathing while relative humidity and temperature were modified. Breathing resistance was measured over 120 min using a calibrated pressure transducer under four different temperature and relative humidity conditions without aerosol loading. Particle penetration was evaluated before and after the breathing resistance test at room conditions using a sodium chloride aerosol measured with a scanning mobility particle sizer. Results demonstrated that increasing relative humidity and lowering external temperature caused significant increases in breathing resistance (p < 0.001). However, these same conditions did not influence the penetration or most penetrating particle size of the tested FFRs. The increase in breathing resistance varied by FFR model suggesting that some FFR media are less influenced by high relative humidity.

  2. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  3. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  4. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  5. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  6. Prevalence of abnormal lactose breath hydrogen tests in children with functional abdominal pain.

    PubMed

    Garg, Neha; Basu, Srikanta; Singh, Preeti; Kumar, Ruchika; Sharma, Lokesh; Kumar, Praveen

    2017-05-01

    The study was undertaken to determine the prevalence of abnormal lactose breath hydrogen test in children with non-organic chronic abdominal pain. Children with chronic abdominal pain were examined and investigated for organic causes. All children without a known organic cause underwent lactose and glucose breath hydrogen test. After a standard dose of 2 g/kg of lactose to a maximum of 50 g, hydrogen in breath was measured at 15 min intervals for 3 h. A rise of 20 ppm above baseline was considered suggestive of lactose malabsorption. Of 108 children screened, organic causes were found in 46 children. Sixty-two patients without any organic cause underwent hydrogen breath test. Lactose hydrogen breath test (HBT) was positive in 36 of 62 (58%), while 11 (17%) had positive HBT with glucose suggestive of small intestinal bacterial overgrowth (SIBO). Twenty out of 34 (59%) improved on lactose free diet while 8 out of 11 (72%) children of SIBO improved on antibiotics. Lactose malabsorption was seen in 58% of children with non-organic chronic abdominal pain.

  7. Breathing metabolic simulator

    NASA Technical Reports Server (NTRS)

    Bartlett, R. G.; Hendricks, C. M.; Morison, W. B.

    1972-01-01

    The development of a breathing metabolic simulator (BMS) is reported. This BMS simulates all of the breathing and metabolic parameters required for complete evaluation and test of life support and resuscitation equipment. It is also useful for calibrating and validating mechanical and gaseous pulmonary function test procedures. Breathing rate, breathing depth, breath velocity contour, oxygen uptake, and carbon dioxide release are all variable over wide ranges simulating conditions from sleep to hard work with respiratory exchange ratios covering the range from hypoventilation. In addition, all of these parameters are remotely controllable to facilitate use of the device in hostile or remote environments. The exhaled breath is also maintained at body temperature and a high humidity. The simulation is accurate to the extent of having a variable functional residual capacity independent of other parameters.

  8. Role of protein kinase C-α in hypertonicity-stimulated urea permeability in mouse inner medullary collecting ducts.

    PubMed

    Wang, Yanhua; Klein, Janet D; Froehlich, Otto; Sands, Jeff M

    2013-01-15

    The kidney's ability to concentrate urine is vitally important to our quality of life. In the hypertonic environment of the kidney, urea transporters must be regulated to optimize function. We previously showed that hypertonicity increases urea permeability and that the protein kinase C (PKC) blockers chelerythrine and rottlerin decreased hypertonicity-stimulated urea permeability in rat inner medullary collecting ducts (IMCDs). Because PKCα knockout (PKCα(-/-)) mice have a urine-concentrating defect, we tested the effect of hypertonicity on urea permeability in isolated perfused mouse IMCDs. Increasing the osmolality of perfusate and bath from 290 to 690 mosmol/kgH(2)O did not change urea permeability in PKCα(-/-) mice but significantly increased urea permeability in wild-type mice. To determine whether the response to protein kinase A was also missing in IMCDs of PKCα(-/-) mice, tubules were treated with vasopressin and subsequently with the PKC stimulator phorbol dibutyrate (PDBu). Vasopressin stimulated urea permeability in PKCα(-/-) mice. Like vasopressin, forskolin stimulated urea permeability in PKCα(-/-) mice. We previously showed that, in rats, vasopressin and PDBu have additive stimulatory effects on urea permeability. In contrast, in PKCα(-/-) mice, PDBu did not further increase vasopressin-stimulated urea permeability. Western blot analysis showed that expression of the UT-A1 urea transporter in IMCDs was increased in response to vasopressin in wild-type mice as well as PKCα(-/-) mice. Hypertonicity increased UT-A1 phosphorylation in wild-type mice but not in PKCα(-/-) mice. We conclude that PKCα mediates hypertonicity-stimulated urea transport but is not necessary for vasopressin stimulation of urea permeability in mouse IMCDs.

  9. [Application of the breath hydrogen test in gastroenterology].

    PubMed

    Loranskaia, I D; Panina, N A; Zheltakova, O V

    2006-01-01

    The diagnostic capacities of the breath hydrogen test in gastroenterology are discussed in the article. The authors describe the results of their own research--determination of the intestinal bacterial contamination in patients with chronic biliary pancreatitis with the help of the Micro H2 breath hydrogen analyzer.

  10. Breathing simulator of workers for respirator performance test.

    PubMed

    Yuasa, Hisashi; Kumita, Mikio; Honda, Takeshi; Kimura, Kazushi; Nozaki, Kosuke; Emi, Hitoshi; Otani, Yoshio

    2015-01-01

    Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker's respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns.

  11. BreathDx - molecular analysis of exhaled breath as a diagnostic test for ventilator-associated pneumonia: protocol for a European multicentre observational study.

    PubMed

    van Oort, Pouline M P; Nijsen, Tamara; Weda, Hans; Knobel, Hugo; Dark, Paul; Felton, Timothy; Rattray, Nicholas J W; Lawal, Oluwasola; Ahmed, Waqar; Portsmouth, Craig; Sterk, Peter J; Schultz, Marcus J; Zakharkina, Tetyana; Artigas, Antonio; Povoa, Pedro; Martin-Loeches, Ignacio; Fowler, Stephen J; Bos, Lieuwe D J

    2017-01-03

    The diagnosis of ventilator-associated pneumonia (VAP) remains time-consuming and costly, the clinical tools lack specificity and a bedside test to exclude infection in suspected patients is unavailable. Breath contains hundreds to thousands of volatile organic compounds (VOCs) that result from host and microbial metabolism as well as the environment. The present study aims to use breath VOC analysis to develop a model that can discriminate between patients who have positive cultures and who have negative cultures with a high sensitivity. The Molecular Analysis of Exhaled Breath as Diagnostic Test for Ventilator-Associated Pneumonia (BreathDx) study is a multicentre observational study. Breath and bronchial lavage samples will be collected from 100 and 53 intubated and ventilated patients suspected of VAP. Breath will be analysed using Thermal Desorption - Gas Chromatography - Mass Spectrometry (TD-GC-MS). The primary endpoint is the accuracy of cross-validated prediction for positive respiratory cultures in patients that are suspected of VAP, with a sensitivity of at least 99% (high negative predictive value). To our knowledge, BreathDx is the first study powered to investigate whether molecular analysis of breath can be used to classify suspected VAP patients with and without positive microbiological cultures with 99% sensitivity. UKCRN ID number 19086, registered May 2015; as well as registration at www.trialregister.nl under the acronym 'BreathDx' with trial ID number NTR 6114 (retrospectively registered on 28 October 2016).

  12. Small intestinal malabsorption in chronic alcoholism: a retrospective study of alcoholic patients by the ¹⁴C-D-xylose breath test.

    PubMed

    Hope, Håvar; Skar, Viggo; Sandstad, Olav; Husebye, Einar; Medhus, Asle W

    2012-04-01

    The ¹⁴C-D-xylose breath test was used at Ullevål University Hospital in the period from 1986 TO 1995 for malabsorption testing. The objective of this retrospective study was to reveal whether patients with chronic alcoholism may have intestinal malabsorption. The consecutive ¹⁴C-D-xylose breath test database was reviewed and patients with the diagnosis of chronic alcoholism were identified. ¹⁴C-D-xylose breath test results of the alcoholic patients were compared with the results of untreated celiac patients and patient and healthy controls. In the ¹⁴C-D-xylose breath test, ¹⁴C-D-xylose was dissolved in water and given orally after overnight fast. Breath samples were taken at 30-min intervals for 210 min, and ¹⁴CO₂ : ¹²CO₂ ratios were calculated for each time point, presenting a time curve for ¹⁴C-D-xylose absorption. Urine was collected after 210 min and the fraction of the total d-xylose passed was calculated (U%). ¹⁴CO₂ in breath and ¹⁴C-D-xylose in urine were analyzed using liquid scintillation. Both breath and urine analysis revealed a pattern of malabsorption in alcoholics comparable with untreated celiac patients, with significantly reduced absorption of d-xylose compared with patient and healthy controls. Alcoholic patients have a significantly reduced ¹⁴C-D-xylose absorption, comparable with untreated celiac patients. This indicates a reduced intestinal function in chronic alcoholism.

  13. In vivo assessment of the mitochondrial response to caloric restriction in obese women by the 2-keto[1-C]isocaproate breath test.

    PubMed

    Parra, Dolores; González, Alvaro; Martínez, J Alfredo; Labayen, Idoia; Díez, Nieves

    2003-04-01

    The 2-keto[1-(13)C]isocaproate breath test has been proposed as a tool to detect mitochondrial dysfunction in alcoholic liver disease. The aim of this study was to evaluate if the 2-keto[1-(13)C]isocaproate breath test could detect in vivo dynamic changes on mitochondrial activity due to caloric restriction in obese women. Fifteen obese women (body mass index [BMI] > 30 kg/m(2)) participated in the study at baseline. Ten of these women agreed to participate on a diet program to induce body weight loss. Fifteen lean women (BMI < 25 kg/m(2)) were included as a control group. The breath test was performed by the oral administration of the tracer measuring (13)CO(2) enrichment in breath before and after ingestion using isotope ratio mass spectrometry. Body composition, resting energy expenditure, and plasma levels of insulin and leptin were measured. There were no relationships observed between the 2-keto[1-(13)C]isocaproate breath test and the plasma insulin (before diet: P =.863; after diet: P =.879), or leptin (before diet: P =.500; after diet: P =.637). In obese women before treatment, kilograms of fat free mass (P =.108), resting energy expenditure adjusted for body composition (P =.312), and the 2-keto[1-(13)C]isocaproate breath test (P =.205) were similar in comparison to lean women. However, 2-keto[1-(13)C]isocaproate oxidation tended to increase after dieting and was significantly higher than in controls (P =.015). These data suggest that the 2-keto[1-(13)C]isocaproate breath test reflected the adaptive modifications in mitochondrial oxidation in response to caloric restriction in obese women. Copyright 2003 Elsevier, Inc. All rights reserved.

  14. 49 CFR 40.245 - What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... test using a saliva ASD or a breath tube ASD? 40.245 Section 40.245 Transportation Office of the... Alcohol Screening Tests § 40.245 What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD? (a) As the STT or BAT, you must take the following steps when using the saliva...

  15. Prevalence of Helicobacter pylori in the adolescent oral cavity: dependence on orthodontic therapy, oral flora and hygiene.

    PubMed

    Wichelhaus, Andrea; Brauchli, Lorenz; Song, Qunsheng; Adler, Guido; Bode, Günter

    2011-07-01

    Helicobacter pylori (HP) infection usually occurs in childhood. While there are various studies on the prevalence of HP in dental plaque, ours is the first to analyze its prevalence during orthodontic therapy and its interaction with competitive bacteria in adolescents. The prevalence of HP was examined before and during the first 12 weeks of orthodontic therapy with fixed appliances in 11 patients with a mean age of 12.7 years. A total of 93 plaque samples were analyzed using PCR. The data acquired at every consultation were the following: PCR analysis of dental plaque and (13)C urea breath tests for HP, quantitative analyses of saliva for Lactobacilli and Streptococcus mutans, the interproximal plaque index (API), and sulcus bleeding index (SBI). The prevalence of HP in plaque was 82% before orthodontic therapy, dropping to 54% during therapy (t test, p≤0.05). In contrast to HP's prevalence, the Lactobacilli count rose (p≤0.05). The number of Streptococcus mutans bacteria in saliva decreased during orthodontic therapy (p≤0.05). The prevalence of HP in dental plaque amounted to 82%. Orthodontic treatment did not reduce its prevalence. The prevalence of Lactobacilli was inversely proportional to that of HP.

  16. Prevalence of gastroesophageal reflux disease in a country with a high occurrence of Helicobacter pylori

    PubMed Central

    Bor, Serhat; Kitapcioglu, Gul; Kasap, Elmas

    2017-01-01

    AIM To evaluate the prevalence of gastroesophageal reflux disease (GERD) with additional symptoms, relationship with Helicobacter pylori (H. pylori) of this country-wide study. METHODS Data from 3214 adults were obtained with validated questionnaire. Eight hundred and forty-one subjects were randomized to be tested for H. pylori via the urea breath test. "Frequent symptoms" were defined heartburn and/or regurgitation occurring at least weekly. RESULTS The prevalence of GERD was 22.8%, frequent and occasional heartburn were 9.3%-12.7%, regurgitation were 16.6%-18.7%, respectively. Body mass index (BMI) ≤ 18.5 showed a prevalence of 15%, BMI > 30 was 28.5%. The GERD prevalence was higher in women (26.2%) than men (18.9%) (P < 0001). Overall prevalence of H. pylori was 75.7%. The prevalence was 77.1% in subjects without symptoms vs 71.4% in subjects with GERD (χ2 = 2.6, P = 0.27). Underprivileged with the lowest income people exhibit a higher risk. CONCLUSION GERD is common in Turkey which reflects both Western and Eastern lifestyles with high rate of H. pylori. The presence of H. pylori had no effect on either the prevalence or the symptom profile of GERD. Subjects showing classical symptoms occasionally exhibit more additional symptoms compared with those without classical symptoms. PMID:28210089

  17. Body indices and basic vital signs in Helicobacter pylori positive and negative persons.

    PubMed

    Kopácová, Marcela; Bures, Jan; Koupil, Ilona; Rejchrt, Stanislav; Vorísek, Viktor; Seifert, Bohumil; Pozler, Oldrich; Zivný, Pavel; Douda, Tomás; Palicka, Vladimír; Holcík, Jan

    2007-01-01

    It has been hypothesized that Helicobacter pylori (Hp) infection may contribute to reduced stature, risk of hypertension or obesity. The aim was to evaluate body indices in Hp positive and negative persons. A total of 2436 subjects (4-100 years old) were tested for Hp status by (13)C-urea breath test. Data on height and weight were collected for 84%, and blood pressure for 80% of the study subjects. The prevalence of Hp infection was 41.6%. The odds ratio for a 10-year increase in age was 1.21 (95% CI 1.17-1.25, p-value <0.001). Statistically significant negative association of Hp positivity with body height was most pronounced in the younger age groups, while a positive association of Hp positivity with body mass index was only seen in those aged 15+ years. There was a negative effect of Hp positivity on systolic and diastolic blood pressure in subjects below 25 and a relatively strong positive effect on blood pressure in subjects over 65 years. Residual confounding by social characteristics as a possible explanation for the associations of Hp positivity with height and blood pressure cannot be excluded. Unmeasured factors related to social and family environment may cause the apparent association between Hp positivity and children's growth and blood pressure.

  18. 13C-Mixed Triglyceride Breath Test and Fecal Elastase as an Indirect Pancreatic Function Test in Cystic Fibrosis Infants.

    PubMed

    Kent, Dorothea Stark; Remer, Thomas; Blumenthal, Caron; Hunt, Sharon; Simonds, Sharon; Egert, Sarah; Gaskin, Kevin J

    2018-05-01

    The 'gold standard' test for the indirect determination of pancreatic function status in infants with cystic fibrosis (CF), the 72-hour fecal fat excretion test, is likely to become obsolete in the near future. Alternative indirect pancreatic function tests with sufficient sensitivity and specificity to determine pancreatic phenotype need further evaluation in CF infants. Evaluation of the clinical utility of both the noninvasive, nonradioactive C-mixed triglyceride (MTG) breath test and fecal elastase-1 (FE1) in comparison with the 72-hour fecal fat assessment in infants with CF. C-MTG breath test and the monoclonal and polyclonal FE1 assessment in stool was compared with the 72-hour fecal fat assessment in 24 infants with CF. Oral pancreatic enzyme substitution (PERT; if already commenced) was stopped before the tests. Sensitivity rates between 82% and 100% for CF patients with pancreatic insufficiency assessed by both the C-MTG breath test and the FE1 tests proved to be high and promising. The C-MTG breath test (31%-38%) as well as both FE1 tests assessed by the monoclonal (46%-54%) and the polyclonal (45%) ELISA kits, however, showed unacceptably low-sensitivity rates for the detection of pancreatic-sufficient CF patients in the present study. The C-MTG breath test with nondispersive infrared spectroscopy (NDIRS) technique, as well as both FE1 tests, are not alternatives to the fecal fat balance test for the evaluation of pancreatic function in CF infants during the first year of life.

  19. Testing the ability of non-methylamine osmolytes present in kidney cells to counteract the deleterious effects of urea on structure, stability and function of proteins.

    PubMed

    Khan, Sheeza; Bano, Zehra; Singh, Laishram R; Hassan, Md Imtaiyaz; Islam, Asimul; Ahmad, Faizan

    2013-01-01

    Human kidney cells are under constant urea stress due to its urine concentrating mechanism. It is believed that the deleterious effect of urea is counteracted by methylamine osmolytes (glycine betaine and glycerophosphocholine) present in kidney cells. A question arises: Do the stabilizing osmolytes, non-methylamines (myo-inositol, sorbitol and taurine) present in the kidney cells also counteract the deleterious effects of urea? To answer this question, we have measured structure, thermodynamic stability (ΔG D (o)) and functional activity parameters (K m and k cat) of different model proteins in the presence of various concentrations of urea and each non-methylamine osmolyte alone and in combination. We observed that (i) for each protein myo-inositol provides perfect counteraction at 1∶2 ([myo-inositol]:[urea]) ratio, (ii) any concentration of sorbitol fails to refold urea denatured proteins if it is six times less than that of urea, and (iii) taurine regulates perfect counteraction in a protein specific manner; 1.5∶2.0, 1.2∶2.0 and 1.0∶2.0 ([taurine]:[urea]) ratios for RNase-A, lysozyme and α-lactalbumin, respectively.

  20. Testing the Ability of Non-Methylamine Osmolytes Present in Kidney Cells to Counteract the Deleterious Effects of Urea on Structure, Stability and Function of Proteins

    PubMed Central

    Khan, Sheeza; Bano, Zehra; Singh, Laishram R.; Hassan, Md. Imtaiyaz; Islam, Asimul; Ahmad, Faizan

    2013-01-01

    Human kidney cells are under constant urea stress due to its urine concentrating mechanism. It is believed that the deleterious effect of urea is counteracted by methylamine osmolytes (glycine betaine and glycerophosphocholine) present in kidney cells. A question arises: Do the stabilizing osmolytes, non-methylamines (myo-inositol, sorbitol and taurine) present in the kidney cells also counteract the deleterious effects of urea? To answer this question, we have measured structure, thermodynamic stability (ΔG D o) and functional activity parameters (K m and k cat) of different model proteins in the presence of various concentrations of urea and each non-methylamine osmolyte alone and in combination. We observed that (i) for each protein myo-inositol provides perfect counteraction at 1∶2 ([myo-inositol]:[urea]) ratio, (ii) any concentration of sorbitol fails to refold urea denatured proteins if it is six times less than that of urea, and (iii) taurine regulates perfect counteraction in a protein specific manner; 1.5∶2.0, 1.2∶2.0 and 1.0∶2.0 ([taurine]:[urea]) ratios for RNase-A, lysozyme and α-lactalbumin, respectively. PMID:24039776

  1. [Soil biological activities at maize seedling stage under application of slow/controlled release nitrogen fertilizers].

    PubMed

    Li, Dongpo; Wu, Zhijie; Chen, Lijun; Liang, Chenghua; Zhang, Lili; Wang, Weicheng; Yang, Defu

    2006-06-01

    With pot experiment and simulating field ecological environment, this paper studied the effects of different slow/ controlled release N fertilizers on the soil nitrate - reductase and urease activities and microbial biomass C and N at maize seedling stage. The results showed that granular urea amended with dicyandiamide (DCD) and N-(n-bultyl) thiophosphoric triamide (NBPT) induced the highest soil nitrate-reductase activity, granular urea brought about the highest soil urease activity and microbial biomass C and N, while starch acetate (SA)-coated granular urea, SA-coated granular urea amended with DCD, methyl methacrylate (MMA) -coated granular urea amended with DCD, and no N fertilization gave a higher soil urease activity. Soil microbial C and N had a similar variation trend after applying various kinds of test slow/controlled release N fertilizers, and were the lowest after applying SA-coated granular urea amended with DCD and NBPT. Coated granular urea amended with inhibitors had a stronger effect on soil biological activities than coated granular urea, and MMA-coating had a better effect than SA-coating.

  2. A comparison of standard inhalers for asthma with and without alcohol as the propellant on the measurement of alcohol in breath.

    PubMed

    Ignacio-García, José M; Ignacio-García, Juan M; Almenara-Barrios, José; Chocrón-Giraldez, María J; Hita-Iglesias, Carmen

    2005-01-01

    Because most bronchodilator inhalers contain propellant gases or a small amount of ethanol as a co-solvent, the potential for these products to generate false readings on a evidential breath alcohol instrument was evaluated in 69 volunteers with clinically stable asthma. All subjects underwent a breath test on an infrared breath alcohol analyzer (Alcotest 7110, Dräger, Lübeck, Germany) before the use of the asthma inhaler and 1 and 5 min after inhalation. The effects of antiasthmatic medications delivered by metered dose inhalers (MDIs) with alcohol as a vehicle, alcohol-free MDIs, and dry powder inhalers were assessed in homogeneous groups of four to five patients. All subjects were alcohol-free on the preliminary breath test. One minute after inhalation, negative readings were only observed in 25 (36.2%) of subjects. In 62.3% of patients, apparent alcohol results were considered interferences or unstable readings by the breath-test instrument. One subject showed a final positive breath alcohol level (0.07 mg/L). After the use of dry powder inhalers, valid results without interferences were obtained. However, 89.6% of patients in which bronchodilators were delivered by MDIs (with propellant gases in the aerosol) showed altered partial readings and labeled the final output as "invalid," but tests performed 5 min after the use of inhalers were valid and correct in all cases. MDIs with propellants as a vehicle may cause false positive breath alcohol readings in some patients. These effects are transient and may be prevented by a 5-10-min interval between the use of MDIs and breath alcohol testing.

  3. Evaluation of the Determination of Free Urea in Water-Soluble Liquid Fertilizers Containing Urea and Ureaforms by Urease and HPLC Methods.

    PubMed

    Hojjatie, Michael M; Abrams, Dean

    2015-01-01

    Currently there are three AOAC Official Methods for the determination of urea in fertilizers. AOAC Official Method 959.03, Urea in Fertilizers, Urease Method, First Action 1959, Final Action 1960, is based on the use of fresh commercial 1% urease solution, or preparation of such solution from urease powder in water, or from jack bean meal in water. AOAC Official Method 983.01, Urea and Methyleneureas (Water-Soluble) in Fertilizers, First Action 1983, Final Action 1984, is based on LC with a refractive index detector using water as the mobile phase and a C18 column. AOAC Official Method 2003.14, Determination of Urea in Water- Soluble Urea-Formaldehyde Fertilizer Products and in Aqueous Urea Solutions, First Action 2003, Final Action 2008, is based on LC with a UV detector using acetonitrile-water (85+15, v/v) mobile phase and a propylamine column. The urea method, AOAC Official Method 959.03, is very much dependent on the nature of the urease enzyme. The method was developed in 1960 and used for simple urea fertilizer solutions. With the advent of complex fertilizer compositions, especially with the class of liquid triazone fertilizers and water-soluble urea forms, the analyses of free urea in these fertilizers by the urease method is often inaccurate and inconsistent. AOAC Official Method 983.01 is not always reliable due to the interference of some of the components of these fertilizers, and due to the fact that the use of water as the mobile phase does not always separate the free urea from other components. AOAC Official Method 2003.14 was subjected to ring test studies that showed it could be used for the determination of "free urea" in these classes of fertilizers with good accuracy and precision.

  4. Role of protein kinase C-α in hypertonicity-stimulated urea permeability in mouse inner medullary collecting ducts

    PubMed Central

    Klein, Janet D.; Froehlich, Otto; Sands, Jeff M.

    2013-01-01

    The kidney's ability to concentrate urine is vitally important to our quality of life. In the hypertonic environment of the kidney, urea transporters must be regulated to optimize function. We previously showed that hypertonicity increases urea permeability and that the protein kinase C (PKC) blockers chelerythrine and rottlerin decreased hypertonicity-stimulated urea permeability in rat inner medullary collecting ducts (IMCDs). Because PKCα knockout (PKCα−/−) mice have a urine-concentrating defect, we tested the effect of hypertonicity on urea permeability in isolated perfused mouse IMCDs. Increasing the osmolality of perfusate and bath from 290 to 690 mosmol/kgH2O did not change urea permeability in PKCα−/− mice but significantly increased urea permeability in wild-type mice. To determine whether the response to protein kinase A was also missing in IMCDs of PKCα−/− mice, tubules were treated with vasopressin and subsequently with the PKC stimulator phorbol dibutyrate (PDBu). Vasopressin stimulated urea permeability in PKCα−/− mice. Like vasopressin, forskolin stimulated urea permeability in PKCα−/− mice. We previously showed that, in rats, vasopressin and PDBu have additive stimulatory effects on urea permeability. In contrast, in PKCα−/− mice, PDBu did not further increase vasopressin-stimulated urea permeability. Western blot analysis showed that expression of the UT-A1 urea transporter in IMCDs was increased in response to vasopressin in wild-type mice as well as PKCα−/− mice. Hypertonicity increased UT-A1 phosphorylation in wild-type mice but not in PKCα−/− mice. We conclude that PKCα mediates hypertonicity-stimulated urea transport but is not necessary for vasopressin stimulation of urea permeability in mouse IMCDs. PMID:23097465

  5. Effects of different sources of fertilizer nitrogen on growth and nutrition of western hemlock seedlings.

    Treesearch

    M.A. Radwan; Dean S. DeBell

    1980-01-01

    Twelve different nitrogen (N) fertilizer treatments were tested on potted western hemlock (Tsuga heterophylla (Raf.) Sarg.) seedlings. Fertilizers affected soil N and pH, and growth and foliar chemical composition of seedlings. Urea plus N-Serve and sulfur-coated urea appear more promising for promoting growth than other fertilizers tested. Results...

  6. Differential expression of multiple glutamine synthetase genes in air-breathing magur catfish, Clarias magur and their induction under hyper-ammonia stress.

    PubMed

    Banerjee, Bodhisattwa; Koner, Debaprasad; Bhuyan, Gitalee; Saha, Nirmalendu

    2018-06-01

    The present study demonstrates the unique presence of three different gs genes (cmgs01, cmgs02, and cmgs03) in air-breathing ureogenic magur catfish (Clarias magur), which is otherwise reported to be encoded by a single gene in higher vertebrates. Of these three genes, two (cmgs01and cmgs03) were identified as 'liver' form, predominantly expressed in liver cells, and the third one as 'brain' form (cmgs02), expressed chiefly in brain cells. Molecular characterization studies have revealed conservation of homologous active site residues in all the three gs genes. In silico analysis, accompanied by GS enzyme assay and Western blot analysis of different GS isoforms in different subcellular fractions indicated the mitochondrial localization of cmGS01 and cmGS03 in liver and kidney cells and cytosolic localization of cmGS02 in brain cells. Further, exposure of magur catfish to high external ammonia (HEA; 25 mM NH 4 Cl) led to a significant induction of multiple gs genes as evidenced by higher expression of different gs mRNAs at variable levels in different tissues. The cmgs01 and cmgs03 mRNA levels elevated significantly in liver, kidney, muscle, and gills, whereas the cmgs02 mRNA level increased considerably in the brain after 14 days of exposure to HEA. These increases in mRNA levels were associated with a significant rise in cmGS01 and cmGS03 proteins in liver, kidney, muscle, and gills, and the cmGS02 protein in the brain after 14 days of exposure to HEA. Therefore, it can be concluded that the unique differential expression of three gs genes and their induction under high ammonia level probably helps in detoxification of ammonia to glutamine and further to urea via the ornithine-urea cycle in ureogenic as well as non-ureogenic tissues of these magur catfish. Copyright © 2017. Published by Elsevier B.V.

  7. 40 CFR 63.2992 - How do I conduct a performance test?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... specified free-formaldehyde content that will be used. (2) You must operate at the maximum feasible urea-formaldehyde resin solids application rate (pounds urea-formaldehyde resin solids applied per hour) that will...

  8. Breathing simulator of workers for respirator performance test

    PubMed Central

    YUASA, Hisashi; KUMITA, Mikio; HONDA, Takeshi; KIMURA, Kazushi; NOZAKI, Kosuke; EMI, Hitoshi; OTANI, Yoshio

    2014-01-01

    Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker’s respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns. PMID:25382381

  9. [Utilisation of salivary markers in nephrology].

    PubMed

    Podracká, Ľudmila; Celec, Peter; Šebeková, Katarína

    2016-01-01

    Saliva has a broad diagnostic potential which can be used for detection many pathological conditions including renal dysfunction. In saliva can be measured concentration of urea and creatinine as well as the other uremic markers. Saliva urea nitrogen and creatinine and blood urea and creatinine highly correlated therefore might be used for screening in patients with CKD. Saliva collection is truly non-invasive and is especially suitable for small children and elderly patients. Recently, semiquantitative saliva urea test strip is available. Saliva might become promising dia-gnostic biofluid in nephrological practice.Key words: chronic kidney disease - renal failure - salivary dipstick - salivary markers.

  10. Ethane-Bridged Bisporphyrin Conformational Changes As an Effective Analytical Tool for Nonenzymatic Detection of Urea in the Physiological Range.

    PubMed

    Buccolieri, Alessandro; Hasan, Mohammed; Bettini, Simona; Bonfrate, Valentina; Salvatore, Luca; Santino, Angelo; Borovkov, Victor; Giancane, Gabriele

    2018-06-05

    Conformational switching induced in ethane-bridged bisporphyrins was used as a sensitive transduction method for revealing the presence of urea dissolved in water via nonenzymatic approach. Bisporphyrins were deposited on solid quartz slides by means of the spin-coating method. Molecular conformations of Zn and Ni monometalated bis-porphyrins were influenced by water solvated urea molecules and their fluorescence emission was modulated by the urea concentration. Absorption, fluorescence and Raman spectroscopies allowed the identification of supramolecular processes, which are responsible for host-guest interaction between the active layers and urea molecules. A high selectivity of the sensing mechanism was highlighted upon testing the spectroscopic responses of bis-porphyrin films to citrulline and glutamine used as interfering agents. Additionally, potential applicability was demonstrated by quantifying the urea concentration in real physiological samples proposing this new approach as a valuable alternative analytical procedure to the traditionally used enzymatic methods.

  11. Exposure to ammonia and acute respiratory effects in a urea fertilizer factory.

    PubMed

    Rahman, Md Hamidur; Bråtveit, Magne; Moen, Bente E

    2007-01-01

    Personal exposures to ammonia and acute respiratory effects were determined in workers at a urea fertilizer factory in Bangladesh. Full-shift personal exposure to ammonia was measured using a PAC III direct reading instrument and Drager diffusion tubes. Respiratory symptoms were elicited by a questionnaire study (n = 113), and preshift and postshift lung function (FVC, FEV1, and PEFR) were tested using spirometry (n = 88). Urea plant workers had higher mean exposure to ammonia and prevalence of acute respiratory symptoms than did workers in the ammonia plant. The symptoms with highest prevalence in the urea plant were chest tightness (33%) and cough (28%). FVC and FEV1 decreased significantly across the work shift among urea plant workers. The higher level of exposure to ammonia in the urea plant was associated with an increased prevalence of respiratory symptoms and an acute decline in lung function.

  12. Control of gill ventilation and air-breathing in the bowfin amia calva

    PubMed

    Hedrick; Jones

    1999-01-01

    The purpose of this study was to investigate the roles of branchial and gas bladder reflex pathways in the control of gill ventilation and air-breathing in the bowfin Amia calva. We have previously determined that bowfin use two distinct air-breathing mechanisms to ventilate the gas bladder: type I air breaths are characterized by exhalation followed by inhalation, are stimulated by aquatic or aerial hypoxia and appear to regulate O2 gas exchange; type II air breaths are characterized by inhalation alone and possibly regulate gas bladder volume and buoyancy. In the present study, we test the hypotheses (1) that gill ventilation and type I air breaths are controlled by O2-sensitive chemoreceptors located in the branchial region, and (2) that type II air breaths are controlled by gas bladder mechanosensitive stretch receptors. Hypothesis 1 was tested by examining the effects of partial or complete branchial denervation of cranial nerves IX and X to the gill arches on gill ventilation frequency (fg) and the proportion of type I air breaths during normoxia and hypoxia; hypothesis II was tested by gas bladder inflation and deflation. Following complete bilateral branchial denervation, fg did not differ from that of sham-operated control fish; in addition, fg was not significantly affected by aquatic hypoxia in sham-operated or denervated fish. In sham-operated fish, aquatic hypoxia significantly increased overall air-breathing frequency (fab) and the percentage of type I breaths. In fish with complete IX-X branchial denervation, fab was also significantly increased during aquatic hypoxia, but there were equal percentages of type I and type II air breaths. Branchial denervation did not affect the frequency of type I air breaths during aquatic hypoxia. Gas bladder deflation via an indwelling catheter resulted in type II breaths almost exclusively; furthermore, fab was significantly correlated with the volume removed from the gas bladder, suggesting a volume-regulating function for type II air breaths. These results indicate that chronic (3-4 weeks) branchial denervation does not significantly affect fg or type I air-breathing responses to aquatic hypoxia. Because type I air-breathing responses to aquatic hypoxia persist after IX-X cranial nerve denervation, O2-sensitive chemoreceptors that regulate air-breathing may be carried in other afferent pathways, such as the pseudobranch. Gas bladder deflation reflexly stimulates type II breaths, suggesting that gas bladder volume-sensitive stretch receptors control this particular air-breathing mechanism. It is likely that type II air breaths function to regulate buoyancy when gas bladder volume declines during the inter-breath interval.

  13. Synthesis and Electrocatalytic Activity of Ammonium Nickel Phosphate, [NH4]NiPO4·6H2O, and β-Nickel Pyrophosphate, β-Ni2P2O7: Catalysts for Electrocatalytic Decomposition of Urea.

    PubMed

    Meguerdichian, Andrew G; Jafari, Tahereh; Shakil, Md R; Miao, Ran; Achola, Laura A; Macharia, John; Shirazi-Amin, Alireza; Suib, Steven L

    2018-02-19

    Electrocatalytic decomposition of urea for the production of hydrogen, H 2, for clean energy applications, such as in fuel cells, has several potential advantages such as reducing carbon emissions in the energy sector and environmental applications to remove urea from animal and human waste facilities. The study and development of new catalyst materials containing nickel metal, the active site for urea decomposition, is a critical aspect of research in inorganic and materials chemistry. We report the synthesis and application of [NH 4 ]NiPO 4 ·6H 2 O and β-Ni 2 P 2 O 7 using in situ prepared [NH 4 ] 2 HPO 4 . The [NH 4 ]NiPO 4 ·6H 2 O is calcined at varying temperatures and tested for electrocatalytic decomposition of urea. Our results indicate that [NH 4 ]NiPO 4 ·6H 2 O calcined at 300 °C with an amorphous crystal structure and, for the first time applied for urea electrocatalytic decomposition, had the greatest reported electroactive surface area (ESA) of 142 cm 2 /mg and an onset potential of 0.33 V (SCE) and was stable over a 24-h test period.

  14. Use of a Non-invasive Test (Entero-test) in the Detection of Helicobacter pylori in Children in an Endemic Area in Colombia

    PubMed Central

    Arboleda, Richard N; Schneider, Barbara G; Bravo, Luis E; Romero-Gallo, Judith; Peek, Richard M; Mera, Robertino M; Yepez, Maria Clara; Campo, Cristina; Correa, Pelayo

    2013-01-01

    Objectives Gastric infection with Helicobacter pylori (H. pylori), a strong risk factor for gastric cancer, is highly prevalent in children residing in the Colombian Andes. We aimed to validate the use of the Entero-test to culture and genotype H. pylori strains from asymptomatic Colombian children. Methods Children (age 10–15y, n=110, 80 of which were H. pylori-positive by the urea breath test, or UBT) were subjected to the Entero-test, and strings were cultured and/or used for DNA extraction for PCR. These children had been treated for H. pylori in 2007. A second population of children (age 10–15y, n= 95), who had not been previously treated were also subjected to the Entero-test. Results Of UBT+ children in the treated group, 29/80 (36%) Entero-test samples were H. pylori culture positive; 29 additional string extracts were tested by PCR for the H. pylori virulence factors cagA and vacA. PCR from cultures and extracts yielded a Sensitivity of 74% and Specificity of 87%. In the untreated group, 16 of 94 UBT+ children (17%) produced Entero-tests that were culture positive. Fifty-eight of 94 (62%) string extracts were PCR positive for cagA and/or vacA. In previously treated children, H. pylori strains were more often the less virulent vacA s2 (P=0.001), m2 (P=0.006), and i2 genotypes (P=0.039). Conclusions The Entero-test may be used as a non-invasive test to detect H. pylori in asymptomatic children residing in high risk areas for gastric cancer. Treatment of H. pylori in children was associated with less virulent genotypes. PMID:23880626

  15. The administrative project of Helicobacter pylori infection screening among junior high school students in an area of Japan with a high incidence of gastric cancer.

    PubMed

    Kusano, Chika; Gotoda, Takuji; Ishikawa, Hideki; Moriyama, Mitsuhiko

    2017-03-01

    Helicobacter pylori infection is a common chronic infection that is closely associated with gastric cancer, known to be decreasing worldwide. We set up an administrative project of screening examination for H. pylori infection in junior high school students in Akita Prefecture to investigate the current prevalence of H. pylori infection in childhood in an area where the incidence of gastric cancer is particularly high. All students in their second or third year of junior high school (13 to 15 years old) in two cities in Akita Prefecture were recruited. First, a urine-based enzyme-linked immunosorbent assay for detection of H. pylori antibody was performed. Then, a 13 C-urea breath test ( 13 C-UBT) was carried out in students who tested positive on the urinary test. Written informed consent was obtained from all participants and their parents. A total of 1813 students were recruited in this study; 1765 (97.3%) students agreed to participate in this project and underwent a screening examination. Among 96 students (5.4%) testing positive for H. pylori on the initial screening examination, 90 (93.7%, 90/96) underwent a subsequent 13 C-UBT, and 85 (4.8%, 85/1765) were diagnosed as positive for H. pylori. The current prevalence of H. pylori infection among students was low even in an area of Japan with a high incidence of gastric cancer.

  16. A Ringdown Breath Analyzer for Diabetes Monitoring: Breath Acetone in Diabetic Patients.

    NASA Astrophysics Data System (ADS)

    Wang, Chuji; Mbi, Armstrong; Shepherd, Mark

    2008-03-01

    It is highly desirable for millions of diabetic patients to have a non-blood, non-invasive, point-of-care device for monitoring daily blood glucose (BG) levels and the adequacy of diabetic treatment and control. Cavity ringdown spectroscopy, due to its unique capability of high sensitivity, fast-response, and relatively low cost for instrumentation, has the potential for medical application through non-invasive analysis of breath biomarkers. We report the first ringdown acetone breath analyzer for clinic testing with diabetic outpatients. The instrument was set in a clinic center and 34 outpatients (24 T1D and 10 T2D) were tested during a four-day period. 10 T1D subjects and 15 nondiabetic persons were tested in our laboratory. Three juvenile-onset T1D subjects were selected for a 24-hr monitoring on the variations of breath acetone and simultaneous BG level. In this talk, we present our research findings including the correlations of breath acetone with BG level and A1C.

  17. [Examination of gastric emptying rate by means of 13C-octanoic acid breath test. Methods of the test for adults and results of the investigation of healthy volunteers].

    PubMed

    Bures, J; Kopácová, M; Vorísek, V; Bukac, J; Neumann, D; Rejchrt, S; Pozler, O; Douda, T; Zivný, P; Palicka, V

    2005-01-01

    13C-octanoic acid breath test (13C-OABT) is a simple, safe and non-invasive technique for measuring gastric emptying. However, the method has not been standardized yet. Aim of the study was to work up, introduce and evaluate our own method of the 13C-OABT for adults. Ten healthy volunteers entered the study (5 men, 5 women, mean age 32 years, 50 % Helicobacter pylori positive). Standard test meals (with 100 mg 13C-sodium octanoate) were used three times within 3 weeks. The same solid meal (1,178 kJ) for Tests 1 and 2 contained scrambled egg (+ 3 g oil), white bread (40 g), butter (10 g) and distilled water (200 ml). Semi-solid meal (1,020 kJ) for Test 3 contained milk pudding (200 g) and distilled water (200 ml). Duplicate breath samples were obtained before and every 15 minutes after eating the test meal during 255 minutes. Altogether 1,080 breath samples were analysed twice (isotope ratio mass spectrometry, AP2003 Analytical Precision, UK). To assess the half-life of elimination (t1/2 E), we modelled the process of elimination with the incomplete gamma-function, which has a convenient form for the empiric plotting of breath test data. Mean t1/2E was 136+/-10 minutes (Test 1), 134+/-14 (Test 2) and 123+/-16 minutes (Test 3). Clinical reproducibility of 13C-OABT in particular persons was 98.2% (18 breath samples series), 90.8 % (15 samples) and 87.1% (9 breath samples series). There was a significant correlation between Test 1 and Test 2 results (r=0.887, p<0.0001). Mean difference of duplicate breath sample analysis was 1.460 % (in 540 pairs), mean baseline one-day analysis difference was 0.0982 (99.9274% accuracy). In healthy volunteers, normal range of t1/2E is 110-160 minutes for solids and 91-155 minutes for semisolid test meal. Using our own computed mean time of intermediate metabolism of 13C-octanoic acid (76.5+/-7.5 minutes), gastric emptying half-time is 33.5-83.5 minutes for solids and 14.5-78.5 minutes for semisolid test meal in healthy volunteers. The 13C-OABT is accurate non-invasive method for gastric emptying measurement.

  18. Limited electromagnetic interference testing of evidential breath testers

    DOT National Transportation Integrated Search

    1983-05-06

    This report summarizes a limited test program conducted to determine the susceptibility of evidential breath testers (EBTs) to radio frequency interference (RFI). Several comprehensive test protocols were prepared based on procedures developed by the...

  19. Miconazole-Urea in a Buccal Film as a New Trend for Treatment of Resistant Mouth Fungal White Patches

    PubMed Central

    Mady, Omar Y.; Donia, Ahmed M.; Al-Madboly, Lamiaa A.

    2018-01-01

    A growing concern about Candida albicans is the emergence of high incidence of resistance against antifungal agents, which requires searching for new medications or improving the response to the existing members. The objective of this work was to evaluate the effectiveness of the miconazole in the absence and presence of urea, as a penetration enhancer, against C. albicans. In addition to, formulating both of them in a polymer film to be used topically for treatment of mouth fungal white patches caused by C. albicans. A synergistic effect was recorded between this imidazole and urea against the test strain. Miconazole MIC (32 mg/L) was dramatically reduced to 0.0625 mg/L following combination with urea. Transmission electron microscopy explained the mechanisms of action mediated by the test agents. Minimal fungicidal dose of miconazole combined with urea showed early apoptotic cells with condensed chromatin and small blebs. Cytoplasmic leakage and necrosis in some cells was observed at high fungicidal dose. Buccal bioadhesive films were prepared using increasing values of the drug MIC and urea. The physicochemical characters of the prepared films including; film weight, thickness, swelling index, drug content, folding endurance, surface pH, bioadhesion force and time and drug release kinetics, were studied. Microbiological evaluation of all prepared films showed an increase in the inhibition zone diameters for films containing increasing concentrations of both miconazole and urea in a concentration-dependent manner (30–40 mm) compared to miconazole alone (18 mm). Based on our results, the prepared films are promising for buccal administration of miconazole/urea showing synergistic effect for treatment of C. albicans infection. PMID:29867789

  20. A double-blind placebo-controlled randomized trial on probiotics in small bowel bacterial overgrowth in children treated with omeprazole.

    PubMed

    Hegar, Badriul; Hutapea, Esther I; Advani, Najid; Vandenplas, Yvan

    2013-01-01

    To evaluate the incidence of small bowel bacterial overgrowth (SBBO) in children treated with omeprazole, and to test whether probiotics influence the incidence. A double-blinded, placebo-controlled trial was performed in 70 children treated orally during four weeks with 20mg omeprazole per day. Lactobacillus rhamnosus R0011 (1.9×10(9) cfu) and Lactobacillus acidophilus R0052 (0.1×10(9) cfu) were simultaneously given daily to 36 subjects (probiotic group), while 34 subjects received placebo (placebo group). The diagnosis of SBBO was based on the development of suggestive symptoms, in combination with a positive glucose breath test. After one month of proton pump inhibitor (PPI) treatment, 30% (21/70) had a positive breath test suggesting SBBO; of these 62% were symptomatic. Five children developed SBBO-like symptoms, but had a negative breath test; and 44 (63%) were symptom free and had a negative breath test. There was no difference in the incidence of positive breath tests in the probiotic versus the placebo group (33% vs 26.5%; p=0.13). Since symptoms suggesting SBBO developed in 26% of PPI-treated children, and since the glucose breath test was abnormal in 72% of these, this side-effect should be more frequently considered. The probiotic tested did not decrease the risk to develop SBBO. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  1. Validation of 13C-acetic acid breath test by measuring effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice.

    PubMed

    Matsumoto, Kenjiro; Kimura, Hiroshi; Tashima, Kimihito; Uchida, Masayuki; Horie, Syunji

    2008-10-01

    Several methods are used to evaluate gastric motility in rodents, but they all have technical limitations. Recent technical developments enable a convenient method to evaluate gastric motility. The (13)C-acetic acid breath test in rodents is a non-invasive and repeatable method that can be used without physical restraints. The present study aimed to validate the (13)C-acetic acid breath test by measuring the effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice. Loperamide (1-10 mg/kg) and morphine (1.25-10 mg/kg) slowed gastric emptying and decreased the maximum concentration (C(max)) and area under the curve (AUC(90 min)) value in a dose-dependent manner. Mosapride (0.2-5 mg/kg) accelerated gastric emptying and increased C(max) value. Mosapride (20 mg/kg) did not accelerate gastric emptying on the (13)C-breath test. Itopride (30 mg/kg, per os) significantly accelerated gastric emptying compared with the vehicle group. In a comparison with the conventional phenol red test, there was a correlation between the C(max) value of breath test and gastric emptying (%) of phenol red tests in treatment with loperamide or mosapride. These results indicate that the (13)C-acetic acid breath test is an accurate, noninvasive, and simple method for monitoring gastric emptying in mice. This method is useful to assess the effect of drugs and gut function pharmacologically.

  2. Use of Urea Wash ELISA to Distinguish Zika and Dengue Virus Infections.

    PubMed

    Tsai, Wen-Yang; Youn, Han Ha; Tyson, Jasmine; Brites, Carlos; Tsai, Jih-Jin; Pedroso, Celia; Drexler, Jan Felix; Balmaseda, Angel; Harris, Eva; Wang, Wei-Kung

    2018-07-01

    Serologic testing remains crucial for Zika virus diagnosis. We found that urea wash in a Zika virus nonstructural protein 1 IgG ELISA distinguishes secondary dengue virus infection from Zika virus infection with previous dengue (sensitivity 87.5%, specificity 93.8%). This test will aid serodiagnosis, serosurveillance, and monitoring of Zika complications in dengue-endemic regions.

  3. Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

    PubMed

    He, Xinjian; Grinshpun, Sergey A; Reponen, Tiina; McKay, Roy; Bergman, Michael S; Zhuang, Ziqing

    2014-03-01

    The objective of this study was to investigate the effects of breathing frequency and flow rate on the total inward leakage (TIL) of an elastomeric half-mask donned on an advanced manikin headform and challenged with combustion aerosols. An elastomeric half-mask respirator equipped with P100 filters was donned on an advanced manikin headform covered with life-like soft skin and challenged with aerosols originated by burning three materials: wood, paper, and plastic (polyethylene). TIL was determined as the ratio of aerosol concentrations inside (C in) and outside (C out) of the respirator (C in/C out) measured with a nanoparticle spectrometer operating in the particle size range of 20-200nm. The testing was performed under three cyclic breathing flows [mean inspiratory flow (MIF) of 30, 55, and 85 l/min] and five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). A completely randomized factorial study design was chosen with four replicates for each combination of breathing flow rate and frequency. Particle size, MIF, and combustion material had significant (P < 0.001) effects on TIL regardless of breathing frequency. Increasing breathing flow decreased TIL. Testing with plastic aerosol produced higher mean TIL values than wood and paper aerosols. The effect of the breathing frequency was complex. When analyzed using all combustion aerosols and MIFs (pooled data), breathing frequency did not significantly (P = 0.08) affect TIL. However, once the data were stratified according to combustion aerosol and MIF, the effect of breathing frequency became significant (P < 0.05) for all MIFs challenged with wood and paper combustion aerosols, and for MIF = 30 l/min only when challenged with plastic combustion aerosol. The effect of breathing frequency on TIL is less significant than the effects of combustion aerosol and breathing flow rate for the tested elastomeric half-mask respirator. The greatest TIL occurred when challenged with plastic aerosol at 30 l/min and at a breathing frequency of 30 breaths/min.

  4. Effect of urea on heat-induced gelation of bovine serum albumin (BSA) studied by rheology and small angle neutron scattering (SANS)

    NASA Astrophysics Data System (ADS)

    Nnyigide, Osita Sunday; Oh, Yuna; Song, Hyeong Yong; Park, Eun-kyoung; Choi, Soo-Hyung; Hyun, Kyu

    2017-05-01

    This paper reports the effects of urea on the heat-induced gelation of bovine serum albumin (BSA), which was studied by the tube inversion method, rheological measurements, and small-angle neutron scattering (SANS). An increase in the urea concentration accelerated the rate of gelation because the protein molecules have already been unfolded to some extent during sample preparation in the urea solution. In addition, the BSA solution in the presence of urea underwent a sol-gel-sol transition during the time sweep test at a constant temperature of 80oC. On the other hand, the BSA solution without urea turned into a hard and brittle gel that did not return to the solution state during isothermal heating at a constant temperature of 80oC. Aggregation and re-bonding of the denatured and unfolded protein chains led to gel formation. Urea added to the protein denatures its tertiary and secondary structures by simultaneously disrupting the hydrogen bonds, hydrophobic interactions, and altering the solvent properties. Furthermore, urea induces thermoreversible chemical interactions in BSA solutions leading to the formation of a gel with dynamic properties under these experimental conditions.

  5. Urea for long-term treatment of syndrome of inappropriate secretion of antidiuretic hormone.

    PubMed Central

    Decaux, G; Genette, F

    1981-01-01

    The efficacy of oral urea in producing a sufficiently high osmotic diuresis was tested in seven patients with the syndrome of inappropriate secretion of antidiuretic hormone. In all patients urea corrected the hyponatraemia despite a normal fluid intake. Five patients were controlled (serum sodium concentration greater than 128 mmol(mEq)/1) with a dose of 30 g urea daily, and two with 60 g daily. The patients who needed 30 g drank 1-2 1 of fluid daily, while those who needed 60 g drank up to 3.1 per day. No major side effects were noted, even after treatment periods of up to 270 days. These findings suggest that urea is a safe and efficacious treatment of the syndrome of inappropriate secretion of antidiuretic hormone. PMID:6794768

  6. Urea for long-term treatment of syndrome of inappropriate secretion of antidiuretic hormone.

    PubMed

    Decaux, G; Genette, F

    1981-10-24

    The efficacy of oral urea in producing a sufficiently high osmotic diuresis was tested in seven patients with the syndrome of inappropriate secretion of antidiuretic hormone. In all patients urea corrected the hyponatraemia despite a normal fluid intake. Five patients were controlled (serum sodium concentration greater than 128 mmol(mEq)/1) with a dose of 30 g urea daily, and two with 60 g daily. The patients who needed 30 g drank 1-2 1 of fluid daily, while those who needed 60 g drank up to 3.1 per day. No major side effects were noted, even after treatment periods of up to 270 days. These findings suggest that urea is a safe and efficacious treatment of the syndrome of inappropriate secretion of antidiuretic hormone.

  7. The Wagner-Nelson method can generate an accurate gastric emptying flow curve from CO2 data obtained by a 13C-labeled substrate breath test.

    PubMed

    Sanaka, Masaki; Yamamoto, Takatsugu; Ishii, Tarou; Kuyama, Yasushi

    2004-01-01

    In pharmacokinetics, the Wagner-Nelson (W-N) method can accurately estimate the rate of drug absorption from its urinary elimination rate. A stable isotope (13C) breath test attempts to estimate the rate of absorption of 13C, as an index of gastric emptying rate, from the rate of pulmonary elimination of 13CO2. The time-gastric emptying curve determined by the breath test is quite different from that determined by scintigraphy or ultrasonography. In this report, we have shown that the W-N method can adjust the difference. The W-N equation to estimate gastric emptying from breath data is as follows: the fractional cumulative amount of gastric contents emptied by time t = Abreath (t)/Abreath (infinity) + (1/0.65).d[Abreath (t)/Abreath (infinity) ]/dt, where Abreath (t) = the cumulative recovery of 13CO2 in breath by time t and Abreath ( infinity ) = the ultimate cumulative 13CO2 recovery. The emptying flow curve generated by ultrasonography was compared with that generated by the W-N method-adjusted breath test in 6 volunteers. The emptying curves by the W-N method were almost identical to those by ultrasound. The W-N method can generate an accurate emptying flow curve from 13CO2 data, and it can adjust the difference between ultrasonography and the breath test. Copyright 2004 S. Karger AG, Basel

  8. The Effect of Diaphragmatic Breathing on Attention, Negative Affect and Stress in Healthy Adults.

    PubMed

    Ma, Xiao; Yue, Zi-Qi; Gong, Zhu-Qing; Zhang, Hong; Duan, Nai-Yue; Shi, Yu-Tong; Wei, Gao-Xia; Li, You-Fa

    2017-01-01

    A growing number of empirical studies have revealed that diaphragmatic breathing may trigger body relaxation responses and benefit both physical and mental health. However, the specific benefits of diaphragmatic breathing on mental health remain largely unknown. The present study aimed to investigate the effect of diaphragmatic breathing on cognition, affect, and cortisol responses to stress. Forty participants were randomly assigned to either a breathing intervention group (BIG) or a control group (CG). The BIG received intensive training for 20 sessions, implemented over 8 weeks, employing a real-time feedback device, and an average respiratory rate of 4 breaths/min, while the CG did not receive this treatment. All participants completed pre- and post-tests of sustained attention and affect. Additionally, pre-test and post-test salivary cortisol concentrations were determined in both groups. The findings suggested that the BIG showed a significant decrease in negative affect after intervention, compared to baseline. In the diaphragmatic breathing condition, there was a significant interaction effect of group by time on sustained attention, whereby the BIG showed significantly increased sustained attention after training, compared to baseline. There was a significant interaction effect of group and time in the diaphragmatic breathing condition on cortisol levels, whereby the BIG had a significantly lower cortisol level after training, while the CG showed no significant change in cortisol levels. In conclusion, diaphragmatic breathing could improve sustained attention, affect, and cortisol levels. This study provided evidence demonstrating the effect of diaphragmatic breathing, a mind-body practice, on mental function, from a health psychology approach, which has important implications for health promotion in healthy individuals.

  9. Validation of a new mixing chamber system for breath-by-breath indirect calorimetry.

    PubMed

    Kim, Do-Yeon; Robergs, Robert Andrew

    2012-02-01

    Limited validation research exists for applications of breath-by-breath systems of expired gas analysis indirect calorimetry (EGAIC) during exercise. We developed improved hardware and software for breath-by-breath indirect calorimetry (NEW) and validated this system as well as a commercial system (COM) against 2 methods: (i) mechanical ventilation with known calibration gas, and (ii) human subjects testing for 5 min each at rest and cycle ergometer exercise at 100 and 175 W. Mechanical calibration consisted of medical grade and certified calibration gas ((4.95% CO(2), 12.01% O(2), balance N(2)), room air (20.95% O(2), 0.03% CO(2), balance N(2)), and 100% nitrogen), and an air flow turbine calibrated with a 3-L calibration syringe. Ventilation was mimicked manually using complete 3-L calibration syringe manouvers at a rate of 10·min(-1) from a Douglas bag reservoir of calibration gas. The testing of human subjects was completed in a counterbalanced sequence based on 5 repeated tests of all conditions for a single subject. Rest periods of 5 and 10 min followed the 100 and 175 W conditions, respectively. COM and NEW had similar accuracy when tested with known ventilation and gas fractions. However, during human subjects testing COM significantly under-measured carbon dioxide gas fractions, over-measured oxygen gas fractions and minute ventilation, and resulted in errors to each of oxygen uptake, carbon dioxide output, and respiratory exchange ratio. These discrepant findings reveal that controlled ventilation and gas fractions are insufficient to validate breath-by-breath, and perhaps even time-averaged, systems of EGAIC. The errors of the COM system reveal the need for concern over the validity of commercial systems of EGAIC.

  10. [Analysis of breath hydrogen (H2) in diagnosis of gastrointestinal function: validation of a pocket breath H2 test analyzer].

    PubMed

    Braden, B; Braden, C P; Klutz, M; Lembcke, B

    1993-04-01

    Breath hydrogen (H2) analysis, as used in gastroenterologic function tests, requires a stationary analysis system equipped with a gaschromatograph or an electrochemical sensor cell. Now a portable breath H2-analyzer has been miniaturized to pocket size (104 mm x 62 mm x 29 mm). The application of this device in clinical practice has been assessed in comparison to the standard GMI-exhaled monitor. The pocket analyzer showed a linear response to standards with H2-concentrations ranging from 0-100 ppm (n = 7), which was not different from the GMI-apparatus. The correlation of both methods during clinical application (lactose tolerance tests, mouth-to-coecum transit time determined with lactulose) was excellent (Y = 1.08 X + 0.96; r = 0.959). Using the new device, both, analysis (3 s vs. 90 s) and the reset-time (43 s vs. 140 s) were shorter whereas calibration was more feasible with the GMI-apparatus. It is concluded, that the considerably cheaper pocket-sized breath H2-analyzer is as precise and sensitive as the GMI-exhaled monitor, and thus presents a valid alternative for H2-breath tests.

  11. Variability in delivered dose and respirable delivered dose from nebulizers: are current regulatory testing guidelines sufficient to produce meaningful information?

    PubMed

    Hatley, Ross Hm; Byrne, Sarah M

    2017-01-01

    To improve convenience to patients, there have been advances in the operation of nebulizers, resulting in fast treatment times and less drug lost to the environment. However, limited attention has been paid to the effects of these developments on the delivered dose (DD) and respirable delivered dose (RDD). Published pharmacopoeia and ISO testing guidelines for adult-use testing utilize a single breathing pattern, which may not be sufficient to enable effective comparisons between the devices. The DD of 5 mg of salbutamol sulfate into adult breathing patterns with inhalation:exhalation (I:E) ratios between 1:1 and 1:4 was determined. Droplet size was determined by laser diffraction and RDD calculated. Nine different nebulizer brands with different modes of operation (conventional, venturi, breath-enhanced, mesh, and breath-activated) were tested. Between the non-breath-activated nebulizers, a 2.5-fold difference in DD (~750-1,900 µg salbutamol) was found; with RDD, there was a more than fourfold difference (~210-980 µg). With increasing time spent on exhalation, there were progressive reductions in DD and RDD, with the RDD at an I:E ratio of 1:4 being as little as 40% of the dose with the 1:1 I:E ratio. The DD and RDD from the breath-activated mesh nebulizer were independent of the I:E ratio, and for the breath-activated jet nebulizer, there was less than 20% change in RDD between the I:E ratios of 1:1 and 1:4. Comparing nebulizers using the I:E ratio recommended in the guidelines does not predict relative performance between the devices at other ratios. There was significant variance in DD or RDD between different brands of non-breath-activated nebulizer. In future, consideration should be given to revision of the test protocols included in the guidelines, to reflect more accurately the potential therapeutic dose that is delivered to a realistic spectrum of breathing patterns.

  12. A better state-of-mind: deep breathing reduces state anxiety and enhances test performance through regulating test cognitions in children.

    PubMed

    Khng, Kiat Hui

    2017-11-01

    A pre-test/post-test, intervention-versus-control experimental design was used to examine the effects, mechanisms and moderators of deep breathing on state anxiety and test performance in 122 Primary 5 students. Taking deep breaths before a timed math test significantly reduced self-reported feelings of anxiety and improved test performance. There was a statistical trend towards greater effectiveness in reducing state anxiety for boys compared to girls, and in enhancing test performance for students with higher autonomic reactivity in test-like situations. The latter moderation was significant when comparing high-versus-low autonomic reactivity groups. Mediation analyses suggest that deep breathing reduces state anxiety in test-like situations, creating a better state-of-mind by enhancing the regulation of adaptive-maladaptive thoughts during the test, allowing for better performance. The quick and simple technique can be easily learnt and effectively applied by most children to immediately alleviate some of the adverse effects of test anxiety on psychological well-being and academic performance.

  13. The rise in carboxyhemoglobin from repeated pulmonary diffusing capacity tests.

    PubMed

    Zavorsky, Gerald S

    2013-03-01

    The purpose of this study determined the rise in carboxyhemoglobin percentage (COHb) from repeated pulmonary diffusing capacity tests using 5 or 10s single breath-hold maneuvers. Five male and four female non-smokers [baseline COHb=1.2 (SD 0.5%)] performed repeated pulmonary diffusing capacity testing on two separate days. The days were randomized to either repeated 10s (0.28% CO), or 5s (0.28% CO, 55ppm NO) breath-hold maneuvers. Twenty-two 5s breath-hold maneuvers, each separated by 4min rest, raised COHb to 11.1 (1.4)% and minimally raised the methemoglobin percentage (METHb) by 0.3 (0.2)% to a value of 0.8 (0.2)%. After the 22nd test, pulmonary diffusing capacity for carbon monoxide (DLCO) was reduced by about 4mL/min/mmHg, equating to a 0.44% increase in COHb per 5s breath-hold maneuver and a concomitant 0.35mL/min/mmHg decrease in DLCO. Pulmonary diffusing capacity for nitric oxide (DLNO) was not altered after 22 tests. On another day, the 10s single breath-hold maneuver increased COHb by 0.64% per test, and reduced DLCO by 0.44mL/min/mmHg per test. In conclusion, 5s breath-hold maneuvers do not appreciably raise METHb or DLNO, and DLCO is only significantly reduced when COHb is at least 6%. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Reverse iontophoresis of urea in health and chronic kidney disease: a potential diagnostic and monitoring tool?

    PubMed Central

    Ebah, Leonard M; Read, Ian; Sayce, Andrew; Morgan, Jane; Chaloner, Christopher; Brenchley, Paul; Mitra, Sandip

    2012-01-01

    Background Patients with chronic kidney disease (CKD) need regular monitoring, usually by blood urea and creatinine measurements, needing venepuncture, frequent attendances and a healthcare professional, with significant inconvenience. Noninvasive monitoring will potentially simplify and improve monitoring. We tested the potential of transdermal reverse iontophoresis of urea in patients with CKD and healthy controls. Methods Using a MIC 2® Iontophoresis Controller, reverse iontophoresis was applied on the forearm of five healthy subjects (controls) and 18 patients with CKD for 3–5 h. Urea extracted at the cathode was measured and compared with plasma urea. Results Reverse iontophoresis at 250 μA was entirely safe for the duration. Cathodal buffer urea linearly correlated with plasma urea after 2 h (r = 0·82, P < 0·0001), to 3·5 h current application (r = 0·89, P = 0·007). The linear equations y = 0·24x + 1 and y = 0·21x + 4·63 predicted plasma urea (y) from cathodal urea after 2 and 3 h, respectively. Cathodal urea concentration in controls was significantly lower than in patients with CKD after a minimum current application of 2 h (P < 0·0001), with the separation between the two groups becoming more apparent with longer application (P = 0·003). A cathodal urea cut-off of 30 μM gave a sensitivity of 83·3% and positive predictive value of 87% CKD. During haemodialysis, the fall in cathodal urea was able to track that of blood urea. Conclusion Reverse iontophoresis is safe, can potentially discriminate patients with CKD and healthy subjects and is able to track blood urea changes on dialysis. Further development of the technology for routine use can lead to an exciting opportunity for its use in diagnostics and monitoring. PMID:22409780

  15. Improved workflow for quantification of left ventricular volumes and mass using free-breathing motion corrected cine imaging.

    PubMed

    Cross, Russell; Olivieri, Laura; O'Brien, Kendall; Kellman, Peter; Xue, Hui; Hansen, Michael

    2016-02-25

    Traditional cine imaging for cardiac functional assessment requires breath-holding, which can be problematic in some situations. Free-breathing techniques have relied on multiple averages or real-time imaging, producing images that can be spatially and/or temporally blurred. To overcome this, methods have been developed to acquire real-time images over multiple cardiac cycles, which are subsequently motion corrected and reformatted to yield a single image series displaying one cardiac cycle with high temporal and spatial resolution. Application of these algorithms has required significant additional reconstruction time. The use of distributed computing was recently proposed as a way to improve clinical workflow with such algorithms. In this study, we have deployed a distributed computing version of motion corrected re-binning reconstruction for free-breathing evaluation of cardiac function. Twenty five patients and 25 volunteers underwent cardiovascular magnetic resonance (CMR) for evaluation of left ventricular end-systolic volume (ESV), end-diastolic volume (EDV), and end-diastolic mass. Measurements using motion corrected re-binning were compared to those using breath-held SSFP and to free-breathing SSFP with multiple averages, and were performed by two independent observers. Pearson correlation coefficients and Bland-Altman plots tested agreement across techniques. Concordance correlation coefficient and Bland-Altman analysis tested inter-observer variability. Total scan plus reconstruction times were tested for significant differences using paired t-test. Measured volumes and mass obtained by motion corrected re-binning and by averaged free-breathing SSFP compared favorably to those obtained by breath-held SSFP (r = 0.9863/0.9813 for EDV, 0.9550/0.9685 for ESV, 0.9952/0.9771 for mass). Inter-observer variability was good with concordance correlation coefficients between observers across all acquisition types suggesting substantial agreement. Both motion corrected re-binning and averaged free-breathing SSFP acquisition and reconstruction times were shorter than breath-held SSFP techniques (p < 0.0001). On average, motion corrected re-binning required 3 min less than breath-held SSFP imaging, a 37% reduction in acquisition and reconstruction time. The motion corrected re-binning image reconstruction technique provides robust cardiac imaging that can be used for quantification that compares favorably to breath-held SSFP as well as multiple average free-breathing SSFP, but can be obtained in a fraction of the time when using cloud-based distributed computing reconstruction.

  16. Urea, sugar, nonesterified fatty acid and cholesterol content of the blood in prolonged weightlessness

    NASA Technical Reports Server (NTRS)

    Balakhovskiy, I. S.; Orlova, T. A.

    1975-01-01

    Biochemical blood composition studies on astronauts during weightlessness flight simulation tests and during actual space flights showed some disturbances of metabolic processes. Increases in blood sugar, fatty acid and cholesterol, and urea content are noted.

  17. Antibiotics taken for other illnesses and spontaneous clearance of Helicobacter pylori infection in children.

    PubMed

    Broussard, Cheryl S; Goodman, Karen J; Phillips, Carl V; Smith, Mary Ann; Fischbach, Lori A; Day, R Sue; Aragaki, Corinne C

    2009-08-01

    Factors that determine persistence of untreated Helicobacter pylori (H. pylori) infection in childhood are not well understood. We estimated risk differences for the effect of incidental antibiotic exposure on the probability of a detected clearance at the next test after an initial detected H. pylori infection. The Pasitos Cohort Study (1998-2005) investigated predictors of H. pylori infection in children from El Paso, Texas, and Juarez, Mexico. Children were screened for infection at 6-month target intervals from 6 to 84 months of age, using the 13C-urea breath test corrected for body-size-dependent variation in CO2 production. Exposure was defined as courses of any systemic antibiotic (systemic) or those with anti-H. pylori action (HP-effective) reported for the interval between initial detected infection and next test. Binomial regression models included country of residence, mother's education, adequacy of prenatal care, age at infection, and interval between tests. Of 205 children with a test result and antibiotic data following a detected infection, the number of children who took > or =1 course in the interval between tests was 74 for systemic and 33 for HP-effective. The proportion testing negative at the next test was 66% for 0 courses, 72% for > or =1 systemic course, and 79% for > or =1 HP-effective course. Adjusted risk differences (95%CI) for apparent clearance, comparing > or =1 to 0 courses were 10% (1-20%) for systemic and 11% (0-21%) for HP-effective. Incidental antibiotic exposure appears to influence the duration of childhood H. pylori infection but seems to explain only a small portion of spontaneous clearance. Copyright 2009 John Wiley & Sons, Ltd.

  18. Significance of hydrogen breath tests in children with suspected carbohydrate malabsorption

    PubMed Central

    2014-01-01

    Background Hydrogen breath tests are noninvasive procedures frequently applied in the diagnostic workup of functional gastrointestinal disorders. Here, we review hydrogen breath test results and the occurrence of lactose, fructose and sorbitol malabsorption in pediatric patients; and determine the significance of the findings and the outcome of patients with carbohydrate malabsorption. Methods We included 206 children (88 male, 118 female, median age 10.7 years, range 3–18 years) with a total of 449 hydrogen breath tests (lactose, n = 161; fructose, n = 142; sorbitol, n = 146) into a retrospective analysis. Apart from test results, we documented symptoms, the therapeutic consequences of the test, the outcome and the overall satisfaction of the patients and families. Results In total, 204 (46%) of all breath tests were positive. Long-term follow-up data could be collected from 118 patients. Of 79 patients (67%) who were put on a diet reduced in lactose, fructose and/or sorbitol, the majority (92%, n = 73) reported the diet to be strict and only 13% (n = 10) had no response to diet. Most families (96%, n = 113) were satisfied by the test and the therapy. There were only 21 tests (5%) with a borderline result because the criteria for a positive result were only partially met. Conclusions Hydrogen breath tests can be helpful in the evaluation of children with gastrointestinal symptoms including functional intestinal disorders. If applied for a variety of carbohydrates but only where indicated, around two-third of all children have positive results. The therapeutic consequences are successfully relieving symptoms in the vast majority of patients. PMID:24575947

  19. Helicobacter pylori infection amongst Arab Israeli women with hyperemesis gravidarum--a prospective, controlled study.

    PubMed

    Boltin, Doron; Perets, Tsachi Tsadok; Elheiga, Sami Abu; Sharony, Asher; Niv, Yaron; Shamaly, Hussein; Dickman, Ram

    2014-12-01

    Helicobacter pylori has been associated with hyperemesis gravidarum in some geographical regions. The prevalence of H. pylori in Arab Israeli women in the Upper Galilee and its association with hyperemesis gravidarum has not been studied previously. We aimed to examine if hyperemesis gravidarum is associated with H. pylori in this population. Subjects with hyperemesis gravidarum carrying a singleton fetus were recruited prospectively. Women with an uncomplicated pregnancy served as controls. All patients underwent (13)C-urea breath testing to assess for H. pylori infection. A total of 72 subjects, including 24 patients with hyperemesis gravidarum and 48 controls, aged 28.8±5.3 years, were included. H. pylori infection was identified in 75.0% (18/24) of cases and 60.4% (29/48) of controls (p=not significant). H. pylori infection did not correlate with age, fetal sex, or the number of previous pregnancies (p=not significant). H. pylori does not seem to increase the likelihood of hyperemesis gravidarum in Arab Israeli women. However, given the high background prevalence of H. pylori in this population, a larger study is required to corroborate these findings. (MOH20110066). Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Association Between Helicobacter Pylori Infection and Long-term Outcome in Patients with Drug-eluting Stent Implantation

    NASA Astrophysics Data System (ADS)

    Wang, Rui; Chen, Lei-Lei; Wang, De-Zhao; Chen, Bu-Xing

    2017-07-01

    To investigate the relationship between Helicobacter pylori (Hp) infection and the long-term outcome in acute coronary syndrome (ACS) patients with drug-eluting stent (DES) implantation and so as to explore the significance of Hp eradication therapy in preventing major adverse cardiac events (MACE) and upper gastrointestinal bleeding (UGIB). 539 ACS patients with DES implantation from January 1, 2010 to December 31, 2012 were analyzed. All the patients were divided into two groups according to the result of 13C urea breath test. 253 patients with Hp infection were put into group A (Hp+), and 286 cases without Hp infection were put into group B (Hp-). Demographic data was collected and all patients went through biochemical indicators and other routine blood examinations. We explored the correlations of Hp infection with MACE and UGIB after 3 to 5 years of follow-up using survival analysis. Survival analysis showed that Hp infection was a predictor of MACE and UGI. Sub-group analysis showed that patients with Hp eradication therapy had no relationship with MACE but had a lower rate of UGIB than those without Hp eradication therapy.

  1. Are the view of Helicobacter pylori colonized in the oral cavity an illusion?

    PubMed Central

    Yee, J K C

    2017-01-01

    Urea breath test (UBT), as a leading preferred non-invasive diagnostic technology, but may not be able to detect oral H. pylori. With negative results of UBT, the patient may have an oral infection. On the basis of the fact of success, eradication rate may increase by 21% in the 95% Cl range after the elimination of oral H. pylori, the author believes oral H. pylori does exist and the oral cavity is the second colonized site aside its primary site of the stomach. H. pylori migrated out of Africa along with its human host circa 60 000 years ago; they are not lives in stomach only. In this review article, evidence established in recent years studies with use more appropriate technology had been listed and discussed. The author considers the oral cavity is a black hole for H. pylori infection that significant effective on gastroenterology and another medical field. The role of the oral cavity as the source of H. pylori infection is so controvert in past years. It seems like a human being having a second-time face to discover H. pylori in the history. PMID:29170474

  2. The association of drinking water quality and sewage disposal with Helicobacter pylori incidence in infants: the potential role of water-borne transmission.

    PubMed

    Travis, Penny B; Goodman, Karen J; O'Rourke, Kathleen M; Groves, Frank D; Sinha, Debajyoti; Nicholas, Joyce S; VanDerslice, Jim; Lackland, Daniel; Mena, Kristina D

    2010-03-01

    The mode of transmission of Helicobacter pylori, a bacterium causing gastric cancer and peptic ulcer disease, is unknown although waterborne transmission is a likely pathway. This study investigated the hypothesis that access to treated water and a sanitary sewerage system reduces the H. pylori incidence rate, using data from 472 participants in a cohort study that followed children in Juarez, Mexico, and El Paso, Texas, from April 1998, with caretaker interviews and the urea breath test for detecting H. pylori infection at target intervals of six months from birth through 24 months of age. The unadjusted hazard ratio comparing bottled/vending machine water to a municipal water supply was 0.71 (95% confidence interval (CI): 0.50, 1.01) and comparing a municipal sewer connection to a septic tank or cesspool, 0.85 (95% CI: 0.60, 1.20). After adjustment for maternal education and country, the hazard ratios decreased slightly to 0.70 (95% confidence interval: 0.49, 1.00) and 0.77 (95% confidence interval: 0.50, 1.21), respectively. These results provide moderate support for potential waterborne transmission of H. pylori.

  3. Relationship Between Abdominal Symptoms and Fructose Ingestion in Children with Chronic Abdominal Pain.

    PubMed

    Hammer, Veronika; Hammer, Katharina; Memaran, Nima; Huber, Wolf-Dietrich; Hammer, Karin; Hammer, Johann

    2018-05-01

    Limited valid data are available regarding the association of fructose-induced symptoms, fructose malabsorption, and clinical symptoms. To develop a questionnaire for valid symptom assessment before and during a carbohydrate breath test and to correlate symptoms with fructose breath test results in children/adolescents with functional abdominal pain. A Likert-type questionnaire assessing symptoms considered relevant for hydrogen breath test in children was developed and underwent initial validation. Fructose malabsorption was determined by increased breath hydrogen in 82 pediatric patients with functional abdominal pain disorders; fructose-induced symptoms were quantified by symptom score ≥2 and relevant symptom increase over baseline. The results were correlated with clinical symptoms. The time course of symptoms during the breath test was assessed. The questionnaire exhibited good psychometric properties in a standardized assessment of the severity of carbohydrate-related symptoms. A total of 40 % (n = 33) had malabsorption; symptoms were induced in 38 % (n = 31), but only 46 % (n = 15) with malabsorption were symptomatic. There was no significant correlation between fructose malabsorption and fructose-induced symptoms. Clinical symptoms correlated with symptoms evoked during the breath test (p < 0.001, r 2  = 0.21) but not with malabsorption (NS). Malabsorbers did not differ from non-malabsorbers in terms of symptoms during breath test. Symptomatic patients had significantly higher pain and flatulence scores over the 9-h observation period (p < 0.01) than did nonsymptomatic patients; the meteorism score was higher after 90 min. Fructose-induced symptoms but not fructose malabsorption are related to increased abdominal symptoms and have distinct timing patterns.

  4. Measurement of fatigue following 18 msw dry chamber dives breathing air or enriched air nitrox.

    PubMed

    Harris, R J D; Doolette, D J; Wilkinson, D C; Williams, D J

    2003-01-01

    Many divers report less fatigue following diving breathing oxygen rich N2-O2 mixtures compared with breathing air. In this double blinded, randomized controlled study 11 divers breathed either air or Enriched Air Nitrox 36% (oxygen 36%, nitrogen 64%) during an 18 msw (281 kPa(a)) dry chamber dive for a bottom time of 40 minutes. Two periods of exercise were performed during the dive. Divers were assessed before and after each dive using the Multidimensional Fatigue Inventory-20, a visual analogue scale, Digit Span Tests, Stroop Tests, and Divers Health Survey (DHS). Diving to 18m produced no measurable difference in fatigue, attention levels, ability to concentrate or DHS scores, following dives using either breathing gas.

  5. Oral Bacterial Acid–Base Metabolism in Caries Screening: A Proof-Of-Concept Study

    PubMed Central

    Morou-Bermudez, E.; Loza-Herrero, M.A.; Garcia-Rivas, V.; Suarez-Perez, E.; Billings, R.J.

    2016-01-01

    The objective of this cross-sectional study was to clinically validate an array of biochemical tests as caries screening tools for oral acid–alkali generation. Adult subjects (n = 185; mean 33.6 ± 10.6 y) were examined clinically for dental caries using the International Caries Detection and Assessment System (ICDAS) criteria. Bitewing radiographs were used to confirm the interproximal surfaces of posterior teeth. For the purposes of this study, subjects were classified as “caries-active” if they had at least one untreated caries lesion with ICDAS 4 or higher. Pooled supragingival plaque and unstimulated saliva samples were collected and assayed for pH changes from sucrose and urea metabolism using colorimetric tests. The validity of each test to discriminate between “caries-inactive” and “caries-active” subjects was assessed and compared with a commercial bacteriological caries-screening test using roc regression and logistic regression models. The areas under the curve (AUCs) (95% CI) of the plaque-urea (PU, 0.59 (0.51 to 0.67)), plaque-urea-glucose (PUG: 0.59 (0.51 to 0.67)) and saliva-urea-glucose (SUG, 0.59 (0.51 to 0.67)) tests did not differ significantly from the bacteriological tests (CRT-mutans, 0.62 (0.54, 0.70); CRT-lactobacillus, 0.63 (0.56 to 0.71) (P > 0.05), but the plaque-glucose (PG), saliva-glucose (SG), saliva-urea (SU) and saliva-plaque-glucose (SPG) tests had significantly smaller AUCs (P < 0.05). The AUCs for PU, PUG, SUG, and the CRT-mutans tests were larger in subjects who had no existing dental restorations (PU, 0.90 (0.77 to 1.04); PUG, 0.90 (0.79 to 1.01); SUG, 0.89 (0.69 to 1.08); CRT-mutans, 0.90 (0.73 to 1.08)). The incorporation of the biochemical tests into a multidimensional bacteriological/psychosocial caries screening model significantly increased the diagnostic value (sensitivity and specificity, 160.6; AUC, 0.846). In conclusion, as a proof-of-concept, the results of this study indicate that measuring urea metabolism together with sugar metabolism by dental plaque and saliva may have a promising role in caries screening either independently or as part of a multidimensional biological test. Knowledge Transfer Statement: The results of this study indicate that assessment of the oral acid/base balance may have a promising role in caries screening either independently, or as part of a multidimensional test. PMID:28435894

  6. Breath holding spell

    MedlinePlus

    ... such as Riley-Day syndrome or Rett syndrome Iron deficiency anemia A family history of breath holding spells ( ... tests may be done to check for an iron deficiency. Other tests that may be done include: EKG ...

  7. The likelihood of acetone interference in breath alcohol measurement

    DOT National Transportation Integrated Search

    1985-09-01

    This report discusses the significance of possible interference of acetone in breath alcohol testing. The following dimensions were considered: 1) what levels of acetone concentration may appear on the breath; 2) what levels of acetone concentration ...

  8. Arsenic induced toxicity in broiler chicks and its alleviation with ascorbic acid: a toxico-patho-biochemical study

    USGS Publications Warehouse

    Khan, Ahrar; Sharaf, Rabia; Khan, Muhammad Zargham; Saleemi, Muhammad Kashif; Mahmood, Fazal

    2013-01-01

    To find out toxico-pathological effects of arsenic (As) and ameliorating effect of ascorbic acid (Vit C), broilers birds were administered 50 and 250 mg/kg arsenic and Vit C, respectively alone/in combination. As-treated birds exhibited severe signs of toxicity such as dullness, depression, increased thirst, open mouth breathing and watery diarrhea. All these signs were partially ameliorated with the treatment of Vit C. As-treated birds showed a significant decrease in serum total proteins while serum enzymes, urea and creatinine were significantly increased. Alkaline phosphatase and lactate dehydrogenase completely whereas proteins, aspartate aminotransferase (AST), alanine aminotransferase (ALT), urea and creatinine were partial ameliorated in birds treated with As+Vit C as compared to As-treated and control birds. Pale and hemorrhagic liver and swollen kidneys were observed in As-treated birds. Histopathologically, liver exhibited congestion and cytoplasmic vacuolation while in kidneys, condensation of tubular epithelium nuclei, epithelial necrosis, increased urinary spaces, sloughing of tubules from basement membrane and cast deposition were observed in As-treated birds. Pathological lesions were partially ameliorated with the treatment of Vit C. It can be concluded that arsenic induces biochemical and histopathological alterations in broiler birds; however, these toxic effects can be partially attenuated by Vit C.

  9. Biochemical characters and antibiotic susceptibility of Staphylococcus aureus isolates.

    PubMed

    Chakraborty, Subhankari Prasad; Mahapatra, Santanu Kar; Roy, Somenath

    2011-06-01

    To observe the biochemical characters and antibiotic susceptibility of isolated Staphylococcus aureus (S. auerus) strains against some conventional and traditional antibiotics. Thirty post operative pathogenic isolated S. aureus strains were used in this study. Bacterial culture was done in Mueller-Hinton broth at 37 °C. Characters of these strains were determined by traditional biochemical tests such as hydrolysis test of gelatin, urea, galactose, starch and protein, and fermentation of lactose and sucrose. Antibiotic susceptibility were carried out by minimum inhibitory concentration test, minium bactericidal concentration test, disc agar diffusion test and brain heart infusion oxacillin screening agar. From this study, it was observed that 100% S. aureus isolates showed positive results in gelatin, urea and galactose hydrolysis test, 50% isolates were positive in starch hydrolysis test, 35% in protein hydrolysis test, 100% isolates in lactose fermenting test, but no isolate was positive in sucrose fermenting test. Antibiotic susceptibility testing suggested that 20% of isolates were resistant to kanamycin and 46.67% were resistant to oxacillin. These findings show that all these isolates have gelatin, urea, galactose hydrolysis and lactose fermenting activity. 20% of these isolates were resistant to kanamycin and 46.67% were resistant to oxacillin.

  10. Monitoring of urea and potassium by reverse iontophoresis in vitro.

    PubMed

    Wascotte, Valentine; Delgado-Charro, M Begoña; Rozet, Eric; Wallemacq, Pierre; Hubert, Philippe; Guy, Richard H; Préat, Véronique

    2007-06-01

    Reverse iontophoresis is an alternative to blood sampling for the monitoring of endogenous molecules. Here, the potential of the technique to measure urea and potassium levels non-invasively, and to track their concentrations during hemodialysis, has been examined. In vitro experiments were performed to test (a) a series of subdermal urea and potassium concentrations typical of the pathophysiologic range, and (b) a decreasing profile of urea and potassium subdermal concentrations to mimic those which are observed during hemodialysis. (a) After 60-120 min of iontophoresis, linear relationships (p < 0.05) were established between both urea and potassium fluxes and their respective subdermal concentrations. The determination coefficients were above 0.9 after 1 h of current passage using sodium as an internal standard. (b) Reverse iontophoretic fluxes of urea and K(+) closely paralleled the decay of the respective concentrations in the subdermal compartment, as would occur during a hemodialysis session. These in vitro experiments demonstrate that urea and potassium can be quantitatively and proportionately extracted by reverse iontophoresis, even when the subdermal concentrations of the analytes are varying with time. These results suggest the non-invasive monitoring of urea and potassium to diagnose renal failure and during hemodialysis is feasible, and that in vivo measurements are warranted.

  11. 32 CFR 634.8 - Implied consent.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to blood, breath, or urine tests. Persons who drive on the installation shall be deemed to have given their consent to evidential tests for alcohol or other drug content of their blood, breath, or urine...

  12. Metabolic and thyroidal response in air-breathing perch (Anabas testudineus) to water-borne kerosene.

    PubMed

    Peter, Valsa S; Joshua, Elizabeth K; Wendelaar Bonga, Sjoerd E; Peter, M C Subhash

    2007-01-01

    To address the physiological compensatory adaptations in air-breathing fish to a toxicant, we studied the metabolite pattern, serum and liver enzymes and thyroidal response in a tropical air-breathing perch, Anabas testudineus (kept at 30 degrees C in a 12-h L:D cycle) after exposing the fish for 48h to the water-soluble fraction of kerosene. The concentrations of serum glucose (P <0.05), triglycerides (P <0.01) and liver total protein (P <0.05) were significantly increased in kerosene-exposed fish. The serum urea level, however, remained unaffected. A significant (P <0.05) increase in liver RNA occurred without changing the liver DNA concentration. Kerosene exposure decreased the level of aspartate aminotransferase activities in serum (P <0.001) and liver (P <0.05) but it increased (P <0.05) the liver alanine aminotransferase activity without changing its activity in serum. The levels of serum (P <0.01) and liver (P <0.001) lactate dehydrogenase activity were declined and the serum (P <0.05) and liver (P <0.05) alkaline phosphatase activity levels were elevated in kerosene-treated fish. The nominated levels (3.33-6.66ml/L) of kerosene significantly (P <0.01) elevated the thyroxine (T(4)) titre, and reduced (P <0.05) the triiodothyronine (T(3)) titre. The fish pretreated with either T(3) or T(4) and exposed to kerosene had a metabolic and thyroidal response that differed from that in control fish treated with kerosene: no rise in serum glucose was observed, nor in triglycerides, total protein and RNA in the liver, whereas declined levels of T(4) and T(3) were observed. The upregulation of the thyroid along with the marked metabolite changes point to a positive involvement of thyroid in energy metabolism during kerosene exposure. This is consistent with the hypothesis that the fish thyroid responds to the action of petroleum products and influences the metabolic homeostasis of this air-breathing fish.

  13. Enzyme induction in neonates after fetal exposure to antiepileptic drugs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rating, D.; Jaeger-Roman, E.; Nau, H.

    1983-01-01

    The /sup 13/C-AP breath test is shown to be a convenient, noninvasive method to monitor velocity and capacity of P450-dependent AP N-demethylation in infancy and childhood. According to /sup 13/C-AP breath tests, neonates have a very low capacity to eliminate /sup 13/CO/sub 2/, which is only 15 to 21% of the activity in adults. During the first year of life AP N-demethylation increases to reach its maximum at about 2 years; afterwards a slight decrease occurs. In 25 neonates exposed prenatally to different antiepileptic drugs /sup 13/C-AP breath test was efficiently used to prove that cytochrome AP N-demethylation was considerablymore » stimulated. After primidone/phenobarbitone, especially in combination with phenytoin, /sup 13/C elimination reaches and even surpasses the range for older children. Valproate exposure during fetal life is not consistently followed by a significant increase in AP N-demethylation. The enzyme induction demonstrated by /sup 13/C-AP breath test was often accompanied by accelerated metabolic clearance and shortened half-life times of transplacentally acquired antiepileptic drugs. There was good agreement between /sup 13/C-AP breath tests and pharmacokinetic data for primidone/phenobarbitone but not for phenytoin. In contrast, in the case of phenytoin exposure during pregnancy the pharmacokinetic parameters and the /sup 13/C breath test data will transport very different informations about enzyme induction in these neonates.« less

  14. Targeting the Human Complement Membrane Attack Complex to Selectively Kill Prostate Cancer Cells

    DTIC Science & Technology

    2014-12-01

    These mutants will be tested for their specificity and potency against PSA positive/negative cells in conjunction with the PSMA binding urea...targeting studies. Second, to achieve cell binding and uptake, we propose to link a PSMA binding urea to the C-terminus of recombinant GZMB. This will be...will be linked to the free amine of the PSMA urea in order to covalently link the compound to the C- terminus of GZMB. The C-terminus was chosen

  15. Military Nutrition Research: Four Tasks to Address Personnel Readiness and Warfighter Performance

    DTIC Science & Technology

    2007-03-01

    insulin, free fatty acids, beta hydroxybutyrate, glucagon, and IGF-1, epinephrine, norepinephrine, urine creatinine, urine total nitrogen, urine urea...project. • Completion of blood testing for Project 4. Specifically, the following tests were completed: AST, beta hydroxybutyrate, blood urea...Minehira, J-M Schwarz, K Acheson, P Schneiter, J Burri, E Jequier, and L Tappy. Mechanisms of action of ß- glucan in postprandial glucose metabolism

  16. 49 CFR 40.243 - What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD? 40.243 Section 40.243 Transportation Office of the...-evidential breath ASD? As the BAT or STT, you must take the following steps: (a) Select, or allow the...

  17. 49 CFR 40.243 - What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD? 40.243 Section 40.243 Transportation Office of the...-evidential breath ASD? As the BAT or STT, you must take the following steps: (a) Select, or allow the...

  18. Effect of DA-9701 on gastric emptying in a mouse model: assessment by ¹³C-octanoic acid breath test.

    PubMed

    Lim, Chul-Hyun; Choi, Myung-Gyu; Park, Hyeyeon; Baeg, Myong Ki; Park, Jae Myung

    2013-07-21

    To evaluate the effects of DA-9701 on the gastric emptying of a solid meal using the ¹³C-octanoic acid breath test in a mouse model. Male C57BL/6 mice aged > 8 wk and with body weights of 20-25 g were used in this study. The solid test meal consisted of 200 mg of egg yolk labeled with 1.5 L/g ¹³C-octanoic acid. The mice were placed in a 130 mL chamber flushed with air at a flow speed of 200 mL/min. Breath samples were collected for 6 h. The half-emptying time and lag phase were calculated using a modified power exponential model. To assess the reproducibility of the ¹³C-octanoic acid breath test, the breath test was performed two times at intervals of one week in ten mice without drug treatment. To assess the gastrokinetic effects of DA-9701, the breath test was performed three times in another twelve mice, with a randomized crossover sequence of three drug treatments: DA-9701 3 mg/kg, erythromycin 6 mg/kg, or saline. Each breath test was performed at an interval of one week. Repeatedly measured half gastric emptying time of ten mice without drug treatment showed 0.856 of the intraclass correlation coefficient for the half gastric emptying time (P = 0.004). The mean cumulative excretion curve for the ¹³C-octanoic acid breath test showed accelerated gastric emptying after DA-9701 treatment compared with the saline control (P = 0.028). The median half gastric emptying time after the DA-9701 treatment was significantly shorter than after the saline treatment [122.4 min (109.0-137.9 min) vs 134.5 min (128.4-167.0 min), respectively; P = 0.028] and similar to that after the erythromycin treatment [123.3 min (112.9-138.2 min)]. The lag phase, which was defined as the period taken to empty 15% of a meal, was significantly shorter after the DA-9701 treatment than after the saline treatment [48.1 min (44.6-57.1 min) vs 52.6 min (49.45-57.4 min), respectively; P = 0.049]. The novel prokinetic agent DA-9701 accelerated gastric emptying, assessed with repeated measurements in the same mouse using the ¹³C-octanoic acid breath test. Our findings suggest that DA-9701 has therapeutic potential for the treatment of functional dyspepsia.

  19. Distributional shift of urea production site from the extraembryonic yolk sac membrane to the embryonic liver during the development of cloudy catshark (Scyliorhinus torazame).

    PubMed

    Takagi, Wataru; Kajimura, Makiko; Tanaka, Hironori; Hasegawa, Kumi; Ogawa, Shuntaro; Hyodo, Susumu

    2017-09-01

    Urea is an essential osmolyte for marine cartilaginous fishes. Adult elasmobranchs and holocephalans are known to actively produce urea in the liver, muscle and other extrahepatic organs; however, osmoregulatory mechanisms in the developing cartilaginous fish embryo with an undeveloped urea-producing organ are poorly understood. We recently described the contribution of extraembryonic yolk sac membranes (YSM) to embryonic urea synthesis during the early developmental period of the oviparous holocephalan elephant fish (Callorhinchus milii). In the present study, to test whether urea production in the YSM is a general phenomenon among oviparous Chondrichthyes, we investigated gene expression and activities of ornithine urea cycle (OUC) enzymes together with urea concentrations in embryos of the elasmobranch cloudy catshark (Scyliorhinus torazame). The intracapsular fluid, in which the catshark embryo develops, had a similar osmolality to seawater, and embryos maintained a high concentration of urea at levels similar to that of adult plasma throughout development. Relative mRNA expressions and activities of catshark OUC enzymes were significantly higher in YSM than in embryos until stage 32. Concomitant with the development of the embryonic liver, the expression levels and activities of OUC enzymes were markedly increased in the embryo from stage 33, while those of the YSM decreased from stage 32. The present study provides further evidence that the YSM contributes to embryonic urea homeostasis until the liver and other extrahepatic organs become fully functional, and that urea-producing tissue shifts from the YSM to the embryonic liver in the late developmental period of oviparous marine cartilaginous fishes. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Recurrence of Helicobacter pylori infection in Bolivian children and adults after a population-based "screen and treat" strategy.

    PubMed

    Sivapalasingam, Sumathi; Rajasingham, Anu; Macy, Jonathan T; Friedman, Cindy R; Hoekstra, Robert M; Ayers, Tracy; Gold, Benjamin; Quick, Robert E

    2014-10-01

    Strategies to prevent gastric cancer by decreasing Helicobacter pylori infections in high-prevalence, low-income countries could include a population-based "screen and treat" eradication program. We tested residents of two rural villages for H. pylori infection using urea breath test (UBT), treated infected persons using directly observed therapy (DOT), retested for cure, and retested after 1 year later for H. pylori infection. We tested 1,065 (92%) of 1153 residents from two villages in rural Bolivia. Baseline H. pylori prevalence was 80% (95% confidence interval [CI]: 78-84). Age-specific cure rates were similar (≥92%) after DOT. Among those cured, 12% (95% CI: 8-15) had recurrent infection. Age-specific annual H. pylori recurrence rates for combined villages were 20% (95% CI: 10-29) in persons <5 years, 20% (95% CI: 10-29) in 5-9 years, 8% (95% CI: 1-15) in 10-14 years, and 8% (95% CI: 4-12) in persons ≥15 years. Compared with the referent population, those ≥15 years, recurrent infections were significantly more likely in children <5 years (odds ratios [OR] 2.7, 95% CI: 1.2-5.8) and 5-9 years (OR 2.7, 95% CI: 1.4-5.1). Children <10 years had high H. pylori recurrence rates following a population-based screen and treat program; this H. pylori eradication strategy may not be feasible in high-prevalence, low-income settings. © 2014 John Wiley & Sons Ltd.

  1. Effects of homeopathic mother tinctures on breath alcohol testing.

    PubMed

    Boatto, Gianpiero; Trignano, Claudia; Burrai, Lucia; Spanu, Andrea; Nieddu, Maria

    2015-01-01

    In some countries, it is illegal to drive with any detectable amount of alcohol in blood; in others, the legal limit is 0.5 g/L or lower. Recently, some defendants charged with driving under the influence of alcohol and have claimed that positive breath alcohol test results were due to the ingestion of homeopathic mother tinctures. These preparations are obtained by maceration, digestion, infusion, or decoction of herbal material in hydroalcoholic solvent. A series of tests were conducted to evaluate the alcoholic content of three homeopathic mother tinctures and their ability to produce inaccurate breath alcohol results. Nine of 30 subjects gave positive results (0.11-0.82 g/L) when tests were taken within 1 min after drinking mother tincture. All tests taken at least 15 min after the mother tincture consumption and resulted in alcohol-free readings. An observation period of 15-20 min prior to breath alcohol testing eliminates the possibility of false-positive results. © 2014 American Academy of Forensic Sciences.

  2. Urea loading enhances freezing survival and postfreeze recovery in a terrestrially hibernating frog.

    PubMed

    Costanzo, Jon P; Lee, Richard E

    2008-09-01

    We tested the hypothesis that urea, an osmolyte accumulated early in hibernation, functions as a cryoprotectant in the freeze-tolerant wood frog, Rana sylvatica. Relative to saline-treated, normouremic (10 micromol ml(-1)) frogs, individuals rendered hyperuremic (70 micromol ml(-1)) by administration of an aqueous urea solution exhibited significantly higher survival (100% versus 64%) following freezing at -4 degrees C, a potentially lethal temperature. Hyperuremic frogs also had lower plasma levels of intracellular proteins (lactate dehydrogenase, creatine kinase, hemoglobin), which presumably escaped from damaged cells, and more quickly recovered neurobehavioral functions following thawing. Experimental freezing-thawing did not alter tissue urea concentrations, but did elevate glucose levels in the blood and organs of all frogs. When measured 24 h after thawing commenced, glucose concentrations were markedly higher in urea-loaded frogs as compared to saline-treated ones, possibly because elevated urea retarded glucose clearance. Like other low-molecular-mass cryoprotectants, urea colligatively reduces both the amount of ice forming within the body and the osmotic dehydration of cells. In addition, by virtue of certain non-colligative properties, it may bestow additional protection from freeze-thaw damage not afforded by glucose.

  3. Can handling E85 motor fuel cause positive breath alcohol test results?

    PubMed

    Ran, Ran; Mullins, Michael E

    2013-09-01

    Hand-held breath alcohol analyzers are widely used by police in traffic stops of drivers suspected of driving while intoxicated (DWI). E85 is a motor fuel consisting of 85% ethanol and 15% gasoline or other hydrocarbons, and is available at nearly 2,600 stations in the USA. We sought to determine whether handling E85 fuel could produce measurable breath alcohol results using a hand-held analyzer and to see if this would be a plausible explanation for a positive breath alcohol test. Five healthy adult subjects dispensed or transferred 8 US gallons of E85 fuel in each of four scenarios. We measured breath alcohol concentration in g/210 L of exhaled breath using the BACTrack S50 at 0, 2, 4, 6, 8, 10, 15 and 20 min after each fuel-handling scenario. Most of the subjects had no detectable breath alcohol after handling E85 motor fuel. Transient elevations (0.02-0.04 g/210 L) in breath alcohol measurement occurred up to 6 min after handling E85 in a minority of subjects. We conclude that it is unlikely that handling E85 motor fuel would result in erroneous prosecution for DWI.

  4. Determination of breath isoprene and acetone concentration with a needle-type extraction device in gas chromatography-mass spectrometry.

    PubMed

    Ueta, Ikuo; Mizuguchi, Ayako; Okamoto, Mitsuyoshi; Sakamaki, Hiroyuki; Hosoe, Masahiko; Ishiguro, Motoyuki; Saito, Yoshihiro

    2014-03-20

    Isoprene in human breath is said to be related to cholesterol metabolism, and the possibility of the correlations with some clinical parameters has been studied. However, at this stage, no clear benefit of breath isoprene has been reported for clinical diagnosis. In this work, isoprene and acetone concentrations were measured in the breath of healthy and obese subjects using a needle-type extraction device for subsequent analysis in gas chromatography-mass spectrometry (GC-MS) to investigate the possibility of these compounds as an indicator of possible diseases. After measuring intraday and interday variations of isoprene and acetone concentrations in breath samples of healthy subjects, their concentrations were also determined in 80 healthy and 17 obese subjects. In addition, correlation between these breath concentrations and the blood tests result was studied for these healthy and obese subjects. The results indicated successful determination of breath isoprene and acetone in this work, however, no clear correlation was observed between these measured values and the blood test results. Breath isoprene concentration may not be a useful indicator for obesity or hypercholesterolemia. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Can Handling E85 Motor Fuel Cause Positive Breath Alcohol Test Results?

    PubMed Central

    Ran, Ran; Mullins, Michael E.

    2013-01-01

    Hand-held breath alcohol analyzers are widely used by police in traffic stops of drivers suspected of driving while intoxicated (DWI). E85 is a motor fuel consisting of 85% ethanol and 15% gasoline or other hydrocarbons, and is available at nearly 2,600 stations in the USA. We sought to determine whether handling E85 fuel could produce measurable breath alcohol results using a hand-held analyzer and to see if this would be a plausible explanation for a positive breath alcohol test. Five healthy adult subjects dispensed or transferred 8 US gallons of E85 fuel in each of four scenarios. We measured breath alcohol concentration in g/210 L of exhaled breath using the BACTrack S50 at 0, 2, 4, 6, 8, 10, 15 and 20 min after each fuel-handling scenario. Most of the subjects had no detectable breath alcohol after handling E85 motor fuel. Transient elevations (0.02–0.04 g/210 L) in breath alcohol measurement occurred up to 6 min after handling E85 in a minority of subjects. We conclude that it is unlikely that handling E85 motor fuel would result in erroneous prosecution for DWI. PMID:23843422

  6. Rapid Point-Of-Care Breath Test for Biomarkers of Breast Cancer and Abnormal Mammograms

    PubMed Central

    Phillips, Michael; Beatty, J. David; Cataneo, Renee N.; Huston, Jan; Kaplan, Peter D.; Lalisang, Roy I.; Lambin, Philippe; Lobbes, Marc B. I.; Mundada, Mayur; Pappas, Nadine; Patel, Urvish

    2014-01-01

    Background Previous studies have reported volatile organic compounds (VOCs) in breath as biomarkers of breast cancer and abnormal mammograms, apparently resulting from increased oxidative stress and cytochrome p450 induction. We evaluated a six-minute point-of-care breath test for VOC biomarkers in women screened for breast cancer at centers in the USA and the Netherlands. Methods 244 women had a screening mammogram (93/37 normal/abnormal) or a breast biopsy (cancer/no cancer 35/79). A mobile point-of-care system collected and concentrated breath and air VOCs for analysis with gas chromatography and surface acoustic wave detection. Chromatograms were segmented into a time series of alveolar gradients (breath minus room air). Segmental alveolar gradients were ranked as candidate biomarkers by C-statistic value (area under curve [AUC] of receiver operating characteristic [ROC] curve). Multivariate predictive algorithms were constructed employing significant biomarkers identified with multiple Monte Carlo simulations and cross validated with a leave-one-out (LOO) procedure. Results Performance of breath biomarker algorithms was determined in three groups: breast cancer on biopsy versus normal screening mammograms (81.8% sensitivity, 70.0% specificity, accuracy 79% (73% on LOO) [C-statistic value], negative predictive value 99.9%); normal versus abnormal screening mammograms (86.5% sensitivity, 66.7% specificity, accuracy 83%, 62% on LOO); and cancer versus no cancer on breast biopsy (75.8% sensitivity, 74.0% specificity, accuracy 78%, 67% on LOO). Conclusions A pilot study of a six-minute point-of-care breath test for volatile biomarkers accurately identified women with breast cancer and with abnormal mammograms. Breath testing could potentially reduce the number of needless mammograms without loss of diagnostic sensitivity. PMID:24599224

  7. Helicobacter pylori infection with intestinal metaplasia: An independent risk factor for colorectal adenomas

    PubMed Central

    Yan, Ye; Chen, Yi-Na; Zhao, Qian; Chen, Chao; Lin, Chun-Jing; Jin, Yin; Pan, Shuang; Wu, Jian-Sheng

    2017-01-01

    AIM To explore the association between Helicobacter pylori (H. pylori) infection status, intestinal metaplasia (IM), and colorectal adenomas. METHODS We retrospectively reviewed 1641 individuals aged ≥ 40 years who underwent physical examination, laboratory testing, 13C-urea breath testing, gastroscopy, colonoscopy, and an interview to ascertain baseline characteristics and general state of health. Histopathological results were obtained by gastric and colorectal biopsies. RESULTS The prevalence of H. pylori infection and adenomas was 51.5% (845/1641) and 18.1% (297/1641), respectively. H. pylori infection was significantly correlated with an increased risk of colorectal adenomas (crude OR = 1.535, 95%CI: 1.044-1.753, P = 0.022; adjusted OR = 1.359, 95%CI: 1.035-1.785, P = 0.028). Individuals with IM had an elevated risk of colorectal adenomas (crude OR = 1.664, 95%CI: 1.216-2.277, P = 0.001; adjusted OR = 1.381, 95%CI: 0.998-1.929, P = 0.059). Stratification based on H. pylori infection stage and IM revealed that IM accompanied by H. pylori infection was significantly associated with an increased risk of adenomas (crude OR = 2.109, 95%CI: 1.383-3.216, P = 0.001; adjusted OR = 1.765, 95%CI: 1.130-2.757, P = 0.012). CONCLUSION H. pylori-related IM is associated with a high risk of colorectal adenomas in Chinese individuals. PMID:28293091

  8. A comparison of blood alcohol levels as determined by breath and blood tests taken in actual field operations.

    DOT National Transportation Integrated Search

    1972-01-01

    During its 1972 session, the General Assembly of Virginia enacted Senate Bill 104, which authorizes the breath test, as well as the blood test used previously, as a proper chemical test to determine the alcoholic content of the blood. Any person arre...

  9. Positive or negative fructose breath test results do not predict response to fructose restricted diet in children with recurrent abdominal pain: results from a prospective randomized trial.

    PubMed

    Wirth, S; Klodt, C; Wintermeyer, P; Berrang, J; Hensel, K; Langer, T; Heusch, A

    2014-09-01

    To perform a prospective, blinded, randomized interventional trial in patients with recurrent abdominal pain. The primary endpoint was to determine the abdominal pain intensity after 2 weeks of fructose restricted diet. Secondary endpoints were changes of pain frequency and a secondary symptom score (SSS). 103 individuals with recurrent abdominal pain for more than 3 months were randomized. 51 patients were allocated to group A (diet) and 52 to group B (no diet). 2 weeks later the patients underwent hydrogen breath test and were assigned to the test positive or negative group to identify patients with fructose malabsorption. 2 weeks after intervention the pain score decreased significantly from a median 5.5 in group A to 4 and did not change significantly in group B (5.3 to 5). In group A both patients with positive and negative breath tests had a significant lower pain score (-2 and -1.75, respectively). Frequency of abdominal pain decreased in both groups but without significant difference, SSS improved only in group A from median 6 to 3.5. Positive breath test was no predicting factor, neither was abdominal pain during the test. Fructose restricted diet in children and adolescents with recurrent abdominal pain may be of benefit to improve both abdominal pain symptoms and other secondary symptoms. Since a negative breath test result does not exclude a positive response to fructose restriction, the hydrogen breath test does not seem to be the appropriate diagnostic mean to predict the response to the diet. © Georg Thieme Verlag KG Stuttgart · New York.

  10. 13C-methacetin-breath test compared to also noninvasive biochemical blood tests in predicting hepatic fibrosis and cirrhosis in chronic hepatitis C.

    PubMed

    Dinesen, L; Caspary, W F; Chapman, R W; Dietrich, C F; Sarrazin, C; Braden, B

    2008-09-01

    The (13)C-methacetin-breath test and also several noninvasive blood tests comprising routine laboratory parameters have been proposed to predict fibrosis and cirrhosis in chronic hepatitis C. The aim of the study was to compare the diagnostic accuracy between these tests referring to hepatic histology as gold standard. 96 patients with chronic hepatitis C virus infection underwent percutaneous liver biopsy and the (13)C-methacetin-breath test. The Fibroindex, the aspartate aminotransferase to platelet ratio index , and the aspartate aminotransferase to alanine aminotransferase ratio were used as parameters for the staging of fibrosis. The main endpoint was the area under the characteristic curves for the diagnosis of advanced fibrosis (F3-F4) and cirrhosis (F4) according to the Batts Ludwig criteria. ROC analysis revealed a cut-off <14.6 per thousand best with 92.6% sensitivity and 84.1% specificity for the (13)C-methacetin-breath test, for the Fibroindex >1.82 70.4% sensitivity and 91.3% specificity, for the aspartate aminotransferase to platelet ratio >1.0 a 66.7% sensitivity and 75.4% specificity, and for the aspartate aminotransferase to alanine aminotransferase ratio >1.0 63.0% sensitivity and 59.4% specificity in predicting liver cirrhosis. The areas under the curve for the breath test, the Fibroindex, aspartate aminotransferase to platelet ratio and the aspartate aminotransferase to alanine aminotransferase ratio were 0.958, 0.845, 0.799, and 0.688, respectively, when predicting cirrhosis. For identifying patients with advanced fibrosis, the areas under the curve were 0.827, 0.804, 0.779, and 0.561, respectively. Discordances between Fibroindex (21%), aspartate aminotransferase to platelet ratio (29%) or aspartate aminotransferase to alanine aminotransferase ratio (37.6%) and liver biopsy were significantly more frequent than between (13)C-breath test (11.6%) and liver biopsy (P<0.05). The (13)C-methacetin-breath test is more reliable in predicting advanced fibrosis and cirrhosis than simple biochemical parameters (aspartate aminotransferase to platelet ratio; aspartate aminotransferase to alanine aminotransferase ratio).

  11. Comparison between hyperventilation and breath-holding in panic disorder: patients responsive and non-responsive to both tests.

    PubMed

    Nardi, Antonio E; Valença, Alexandre M; Mezzasalma, Marco A; Levy, Sandra P; Lopes, Fabiana L; Nascimento, Isabella; Freire, Rafael C; Veras, Andre B; Zin, Walter A

    2006-06-15

    Our aim was to compare the demographic and psychopathological features of panic disorder (PD) patients who underwent hyperventilation and breath-holding challenge tests, and to describe the features of patients who had a panic attack after both tests versus those patients who did not experience panic after either test. Eighty-five PD patients were induced to hyperventilate (30 breaths/min) for 4 min, and a week later to hold their breath for as long as possible four times with a 2-min interval in between. Anxiety scales were applied before and after the tests. Patients who responded with a panic attack to both tests (BPA, n = 25) were compared with patients who experienced spontaneous panic attacks but did not panic in response to the two tests (NPA, n = 16). The BPA group had a significantly higher presence of respiratory symptoms during a panic attack. The criteria for the respiratory PD subtype were fulfilled in 18 (72.0%) BPA patients and in 6 (37.5%) NPA patients. The BPA patients had a later onset of panic disorder and a higher familial prevalence of PD. Our data suggest that there is a distinction between PD patients who were sensitive to both hyperventilation and breath-holding tests and PD patients who were not affected by the challenge tests. The panic attack may be a final common pathway for different types of stimuli, and respiratory tests may characterize different PD subgroups.

  12. Identification of fish species after cooking by SDS-PAGE and urea IEF: a collaborative study.

    PubMed

    Etienne, M; Jérôme, M; Fleurence, J; Rehbein, H; Kündiger, R; Mendes, R; Costa, H; Pérez-Martín, R; Piñeiro-González, C; Craig, A; Mackie, I; Malmheden Yman, I; Ferm, M; Martínez, I; Jessen, F; Smelt, A; Luten, J

    2000-07-01

    A collaborative study, to validate the use of SDS-PAGE and urea IEF, for the identification of fish species after cooking has been performed by nine laboratories. By following optimized standard operation procedures, 10 commercially important species (Atlantic salmon, sea trout, rainbow trout, turbot, Alaska pollock, pollack, pink salmon, Arctic char, chum salmon, and New Zealand hake) had to be identified by comparison with 22 reference samples. Some differences in the recoveries of proteins from cooked fish flesh were noted between the urea and the SDS extraction procedures used. Generally, the urea extraction procedure appears to be less efficient than the SDS extraction for protein solubilization. Except for some species belonging to the Salmonidae family (Salmo, Oncorhynchus), both of the analytical techniques tested (urea IEF, SDS-PAGE) enabled identification of the species of the samples to be established. With urea IEF, two laboratories could not differentiate Salmo salar from Salmo trutta. The same difficulties were noted for differentiation between Oncorhynchus gorbuscha and Oncorhynchus keta samples. With SDS-PAGE, three laboratories had some difficulties in identifying the S. trutta samples. However, in the contrast with the previous technique, SDS-PAGE allows the characterization of most of the Oncorhynchus species tested. Only Oncorhynchus mykiss was not clearly recognized by one laboratory. Therefore, SDS-PAGE (Excel gel homogeneous 15%) appears to be better for the identification, after cooking, of fish such as the tuna and salmon species which are characterized by neutral and basic protein bands, and urea IEF (CleanGel) is better for the gadoid species, which are characterized by acid protein bands (parvalbumins). Nevertheless, in contentious cases it is preferable to use both analytical methods.

  13. Relationships among the cervical mucus urea and acetone, accuracy of insemination timing, and sperm survival in Holstein cows.

    PubMed

    Beran, J; Stádník, L; Ducháček, J; Okrouhlá, M; Doležalová, M; Kadlecová, V; Ptáček, M

    2013-11-01

    The objectives of this study were to evaluate the relationships among urea and acetone content in cows' cervical mucus (CM), its crystallization type (CT) and sperm survival (SS) after timed AI. Samples of CM were collected from 192 Holstein cows treated by Ovsynch(®) protocol. Analysis of the urea and acetone content for identification of the metabolic status, the arborization test for evaluation of insemination timing and the short-term heat test of SS for assessment of its suitability as a biological matrix were performed. The data set was analyzed by the GLM procedure using SAS(®). The results documented the existence of substantial differences in individual response to the Ovsynch(®) protocol causing insemination of 55.2% cows at an inappropriate time. The urea content was found as a possible indicator of a cow's metabolism and/or of insemination timing, concentrations of less than 500 mg/L corresponded (P<0.05-0.01) to the cows' expected response to timed AI. The greater the urea content, the greater the proportion of cows inseminated at an inappropriate time. Effects (P<0.05-0.01) of CT, urea and acetone content on SS were determined. The greatest values of SS were detected in cows with an expected response to precisely timed oestrus documented by the corresponding CT. Greater values of urea (>260 mg/L) and acetone (>5mg/L) negatively affected SS as well (P<0.05-0.01). The results confirmed that the accuracy of insemination timing can be affected by the metabolism intensity, just as CM quality directly influences sperm survival. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. The combined effects of urea application and simulated acid rain on soil acidification and microbial community structure.

    PubMed

    Liu, Xingmei; Zhou, Jian; Li, Wanlu; Xu, Jianming; Brookes, Philip C

    2014-05-01

    Our aim was to test the effects of simulated acid rain (SAR) at different pHs, when applied to fertilized and unfertilized soils, on the leaching of soil cations (K, Ca, Mg, Na) and Al. Their effects on soil pH, exchangeable H(+) and Al(3+) and microbial community structure were also determined. A Paleudalfs soil was incubated for 30 days, with and without an initial application of urea (200 mg N kg(-1)soil) as nitrogen (N) fertilizer. The soil was held in columns and leached with SAR at three pH levels. Six treatments were tested: SAR of pH 2.5, 4.0 and 5.6 leaching on unfertilized soil (T1, T2 and T3), and on soils fertilized with urea (T4, T5 and T6). Increasing acid inputs proportionally increased cation leaching in both unfertilized and fertilized soils. Urea application increased the initial Ca and Mg leaching, but had no effect on the total concentrations of Ca, Mg and K leached. There was no significant difference for the amount of Na leached between the different treatments. The SAR pH and urea application had significant effects on soil pH, exchangeable H(+) and Al(3+). Urea application, SAR treated with various pH, and the interactions between them all had significant impacts on total phospholipid fatty acids (PLFAs). The highest concentration of total PLFAs occurred in fertilized soils with SAR pH5.6 and the lowest in soils leached with the lowest SAR pH. Soils pretreated with urea then leached with SARs of pH 4.0 and 5.6 had larger total PLFA concentrations than soil without urea. Bacterial, fungal, actinomycete, Gram-negative and Gram-positive bacterial PLFAs had generally similar trends to total PLFAs.

  15. Establishment of Biological Reference Intervals and Reference Curve for Urea by Exploratory Parametric and Non-Parametric Quantile Regression Models.

    PubMed

    Sarkar, Rajarshi

    2013-07-01

    The validity of the entire renal function tests as a diagnostic tool depends substantially on the Biological Reference Interval (BRI) of urea. Establishment of BRI of urea is difficult partly because exclusion criteria for selection of reference data are quite rigid and partly due to the compartmentalization considerations regarding age and sex of the reference individuals. Moreover, construction of Biological Reference Curve (BRC) of urea is imperative to highlight the partitioning requirements. This a priori study examines the data collected by measuring serum urea of 3202 age and sex matched individuals, aged between 1 and 80 years, by a kinetic UV Urease/GLDH method on a Roche Cobas 6000 auto-analyzer. Mann-Whitney U test of the reference data confirmed the partitioning requirement by both age and sex. Further statistical analysis revealed the incompatibility of the data for a proposed parametric model. Hence the data was non-parametrically analysed. BRI was found to be identical for both sexes till the 2(nd) decade, and the BRI for males increased progressively 6(th) decade onwards. Four non-parametric models were postulated for construction of BRC: Gaussian kernel, double kernel, local mean and local constant, of which the last one generated the best-fitting curves. Clinical decision making should become easier and diagnostic implications of renal function tests should become more meaningful if this BRI is followed and the BRC is used as a desktop tool in conjunction with similar data for serum creatinine.

  16. The Effect of Alcohol-Based Hand Sanitizer Vapors on Evidential Breath Alcohol Test Results.

    PubMed

    Strawsine, Ellen; Lutmer, Brian

    2017-11-16

    This study was undertaken to determine if the application of alcohol-based hand sanitizers (ABHSs) to the hands of a breath test operator will affect the results obtained on evidential breath alcohol instruments (EBTs). This study obtained breath samples on three different EBTs immediately after application of either gel or foam ABHS to the operator's hands. A small, but significant, number of initial analyses (13 of 130, 10%) resulted in positive breath alcohol concentrations, while 41 samples (31.5%) resulted in a status code. These status codes were caused by ethanol vapors either in the room air or their inhalation by the subject, thereby causing a mouth alcohol effect. Replicate subject samples did not yield any consecutive positive numeric results. As ABHS application can cause a transitory mouth alcohol effect via inhalation of ABHS vapors, EBT operators should forego the use of ABHS in the 15 min preceding subject testing. © 2017 American Academy of Forensic Sciences.

  17. Synthesis of ¹³C-lidocaine as a probe of breath test for the evaluation of cytochrome P450 activity.

    PubMed

    Mitome, Hidemichi; Sugiyama, Erika; Sato, Hitoshi; Akira, Kazuki

    2014-01-01

    (13)C-Labeled lidocaine, 2-di[1-(13)C]ethylamino-N-(2,6-dimethylphenyl)acetamide (1), was synthesized from [1-(13)C]acetic acid in six steps, as a probe for a breath test to evaluate in vivo cytochrome P450 activity. The measurement of (13)CO2 in breath was successfully performed following oral administration of (13)C-lidocaine 1 to mice.

  18. Effects of alcohol-based hand hygiene solutions on breath alcohol detection in the emergency department.

    PubMed

    Emerson, Beth L; Whitfill, Travis; Baum, Carl R; Garlin-Kane, Katherine; Santucci, Karen

    2016-12-01

    This study aimed to investigate the effects of alcohol-based hand hygiene solution (ABHS) use by care providers on point-of-care alcohol breath analyzer interpretation under different clinically relevant conditions. Among each test condition (foam vehicle with immediate testing, gel vehicle with immediate testing, allowing hands to dry after the use of ABHS, and donning gloves after the use of ABHS), alcohol was detected in breath at 1 minute after use of ABHS. Because the use of ABHS by individuals administering breath alcohol detection may result in false-positive detection of alcohol, staff using these devices should consider traditional hand hygiene with soap and water. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Compressed air demand-type firefighter's breathing system, volume 1. [design analysis and performance tests

    NASA Technical Reports Server (NTRS)

    Sullivan, J. L.

    1975-01-01

    The commercial availability of lightweight high pressure compressed air vessels has resulted in a lightweight firefighter's breathing apparatus. The improved apparatus, and details of its design and development are described. The apparatus includes a compact harness assembly, a backplate mounted pressure reducer assembly, a lightweight bubble-type facemask with a mask mounted demand breathing regulator. Incorporated in the breathing regulator is exhalation valve, a purge valve and a whistle-type low pressure warning that sounds only during inhalation. The pressure reducer assembly includes two pressure reducers, an automatic transfer valve and a signaling device for the low pressure warning. Twenty systems were fabricated, tested, refined through an alternating development and test sequence, and extensively examined in a field evaluation program. Photographs of the apparatus are included.

  20. NASA firefighters breathing system program report

    NASA Technical Reports Server (NTRS)

    Wood, W. B.

    1977-01-01

    Because of the rising incidence of respiratory injury to firefighters, local governments expressed the need for improved breathing apparatus. A review of the NASA firefighters breathing system program, including concept definition, design, development, regulatory agency approval, in-house testing, and program conclusion is presented.

  1. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  2. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  3. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  4. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  5. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  6. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  7. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  8. Safety of first-line triple therapy with a potassium-competitive acid blocker for Helicobacter pylori eradication in children.

    PubMed

    Kusano, Chika; Gotoda, Takuji; Suzuki, Sho; Ikehara, Hisatomo; Moriyama, Mitsuhiko

    2018-06-01

    Helicobacter pylori infection is a risk factor for gastric cancer, and it has been reported that eradication of H. pylori is effective for preventing such cancer. Recently, H. pylori eradication has been performed in children as first-line therapy against gastric cancer. Here, we report use of triple therapy with a potassium-competitive acid blocker (P-CAB) for H. pylori eradication in children. H. pylori infection testing and eradication therapy began in fiscal year 2015 in junior high school students located in Yurihonjo city and Nikaho city, Akita prefecture, Japan. Urine-based immunochromatography, stool antigen enzyme-linked immunosorbent assay tests, and serum antibody tests were performed as the initial screening examination. Those who tested positive on one of the three examinations then underwent a urea breath test ( 13 C-UBT). Those who tested positive on 13 C-UBT and expressed the desire to undergo H. pylori eradication then received eradication therapy comprising 20 mg P-CAB, 750 mg amoxicillin, and 200 mg clarithromycin twice a day for 7 days. At least 8 weeks after treatment, eradication success was evaluated using 13 C-UBT. A total of 118 students received eradication therapy. Eradication rates were 81.3% (95% confidence interval: 74.3-88.4, 96/118) in ITT analysis and 85.7% (95% confidence interval: 79.1-92.9 96/112) in PP analysis. Adverse effects associated with eradication therapy were observed in 25 of 118 subjects (21.1%), seven of whom required hospital treatment (rash in five, vomiting in two). All seven subjects either discontinued therapy or were administered anti-allergy drugs, which resulted in swift alleviation of symptoms. First-line triple therapy with a P-CAB for H. pylori eradication in children was found to be safe.

  9. Cost-effectiveness analysis of universal noninvasive testing for post-treatment confirmation of Helicobacter pylori eradication and the impact of patient adherence.

    PubMed

    Boklage, Susan H; Mangel, Allen W; Ramamohan, Varun; Mladsi, Deirdre; Wang, Tao

    2016-01-01

    The treatment failure rate for Helicobacter pylori eradication therapy is ~20% due to poor patient compliance and increased antibiotic resistance. This analysis assessed the cost-effectiveness of universal post-treatment testing to confirm eradication of H. pylori infection in adults. Decision-analytic models evaluated the cost-effectiveness of universal post-treatment testing (urea breath test [UBT] or monoclonal fecal antigen test [mFAT]) vs no testing (Model 1), and UBT vs mFAT after adjusting for patient adherence to testing (Model 2) in adults who previously received first-line antimicrobial therapy. Patients testing positive received second-line quadruple therapy; no further action was taken for those testing negative or with no testing (Model 1) or for those nonadherent to testing (Model 2). In addition to testing costs, excess lifetime costs and reduced quality-adjusted life-years (QALYs) due to continuing H. pylori infection were considered in the model. Expected total costs per patient were higher for post-treatment testing (UBT: US$325.76; mFAT: US$242.12) vs no testing (US$182.41) in Model 1 and for UBT (US$336.75) vs mFAT (US$326.24) in Model 2. Expected QALYs gained per patient were 0.71 and 0.72 for UBT and mFAT, respectively, vs no testing (Model 1), and the same was 0.37 for UBT vs mFAT (Model 2). The estimated incremental costs per QALY gained for post-treatment testing vs no testing were US$82.90-US$202.45 and, after adjusting for adherence, US$28.13 for UBT vs mFAT. Universal post-treatment testing was found to be cost-effective for confirming eradication of H. pylori infection following first-line therapy. Better adherence to UBT relative to mFAT was the key to its cost-effectiveness.

  10. ERS technical standard on bronchial challenge testing: general considerations and performance of methacholine challenge tests.

    PubMed

    Coates, Allan L; Wanger, Jack; Cockcroft, Donald W; Culver, Bruce H; Diamant, Zuzana; Gauvreau, Gail; Hall, Graham L; Hallstrand, Teal S; Horvath, Ildiko; de Jongh, Frans H C; Joos, Guy; Kaminsky, David A; Laube, Beth L; Leuppi, Joerg D; Sterk, Peter J

    2017-05-01

    This international task force report updates general considerations for bronchial challenge testing and the performance of the methacholine challenge test. There are notable changes from prior recommendations in order to accommodate newer delivery devices. Rather than basing the test result upon a methacholine concentration (provocative concentration (PC 20 ) causing a 20% fall in forced expiratory volume in 1 s (FEV 1 )), the new recommendations base the result upon the delivered dose of methacholine causing a 20% fall in FEV 1 (provocative dose (PD 20 )). This end-point allows comparable results from different devices or protocols, thus any suitable nebuliser or dosimeter may be used, so long as the delivery characteristics are known. Inhalation may be by tidal breathing using a breath-actuated or continuous nebuliser for 1 min (or more), or by a dosimeter with a suitable breath count. Tests requiring maximal inhalations to total lung capacity are not recommended because the bronchoprotective effect of a deep breath reduces the sensitivity of the test. Copyright ©ERS 2017.

  11. Lactose (mal)digestion evaluated by the 13C-lactose digestion test.

    PubMed

    Vonk, R J; Lin, Y; Koetse, H A; Huang, C; Zeng, G; Elzinga, H; Antoine, J; Stellaard, F

    2000-02-01

    The prevalence of genetically determined lactase nonpersistence is based on the results of the lactose H2 breath test. This test, however, is an indirect test, which might lead to misinterpretation. We determined lactase activity in healthy Chinese and Dutch students using a novel 13C-lactose digestion test. The cut-off value of this test was established in a Chinese population with a homogenous genetic background of lactase nonpersistence and was compared with the results obtained in a Caucasian population. Twenty-five grams of a 13C-lactose solution was consumed by 12 known H2-positive and 5 H2-negative Chinese students and 48 Dutch students and, subsequently, 13C-glucose concentration in plasma and H2 excretion in breath were measured. A similar 13C-glucose response curve was found in all Chinese students. The mean response curve in the Dutch students was more pronounced (P < 0.01). The 1 h (peak) plasma 13C-glucose concentration was the best discriminator between lactose digesting and maldigesting subjects. The cut-off level of 2 mmol L-1 13C-glucose in plasma was defined in the H2-positive Chinese students group. Based on the 13C-glucose response the prevalence of lactose maldigestion in the Dutch subjects was 25%; based on the lactose H2 breath test 17%. Using the 13C-lactose digestion test the results demonstrate a higher prevalence of lactose maldigestion in a Caucasian population than indicated by the results of the H2 breath test. A moderate increase in the plasma 13C-glucose concentration after consumption of 13C-lactose in the young adult Chinese subjects indicates a residual lactase activity in that age group, even when a positive H2 breath test result is obtained. These results indicate that the 13C-glucose concentration in plasma more accurately reflects the small intestinal lactose digestion capacity than the lactose H2 breath test.

  12. A new urease-inhibiting formulation decreases ammonia volatilization and improves maize nitrogen utilization in North China Plain

    PubMed Central

    Li, Qianqian; Cui, Xiaoqing; Liu, Xuejun; Roelcke, Marco; Pasda, Gregor; Zerulla, Wolfram; Wissemeier, Alexander H.; Chen, Xinping; Goulding, Keith; Zhang, Fusuo

    2017-01-01

    Overuse of urea, low nitrogen (N) utilization, and large N losses are common in maize production in North China Plain (NCP). To solve these problems, we conducted two field experiments at Shangzhuang and Quzhou in NCP to test the ability of a newly developed urease inhibitor product Limus® to decrease NH3 volatilization from urea applied to maize. Grain yield, apparent N recovery efficiency (REN) and N balance when using urea applied with or without Limus were also measured over two maize growing seasons. Cumulative NH3 loss in the two weeks following urea application without Limus ranged from 9–108 kg N ha−1, while Limus addition significantly decreased NH3 loss by a mean of 84%. Urea with Limus did not significantly increase maize yields (P < 0.05) compared with urea alone. However, a significant 11–17% improvement in REN with Limus was observed at QZ. The use of urea-N plus Limus would permit a reduction in N applications of 55–60% compared to farmers’ practice and/or further 20% N saving compared with optimized urea-N rate (150 kg N ha−1, based on N requirement by target yield of 7.5 t ha−1), and would achieve the same maize yields but with significantly decreased NH3 loss and increased N utilization. PMID:28272451

  13. A new urease-inhibiting formulation decreases ammonia volatilization and improves maize nitrogen utilization in North China Plain

    NASA Astrophysics Data System (ADS)

    Li, Qianqian; Cui, Xiaoqing; Liu, Xuejun; Roelcke, Marco; Pasda, Gregor; Zerulla, Wolfram; Wissemeier, Alexander H.; Chen, Xinping; Goulding, Keith; Zhang, Fusuo

    2017-03-01

    Overuse of urea, low nitrogen (N) utilization, and large N losses are common in maize production in North China Plain (NCP). To solve these problems, we conducted two field experiments at Shangzhuang and Quzhou in NCP to test the ability of a newly developed urease inhibitor product Limus® to decrease NH3 volatilization from urea applied to maize. Grain yield, apparent N recovery efficiency (REN) and N balance when using urea applied with or without Limus were also measured over two maize growing seasons. Cumulative NH3 loss in the two weeks following urea application without Limus ranged from 9-108 kg N ha-1, while Limus addition significantly decreased NH3 loss by a mean of 84%. Urea with Limus did not significantly increase maize yields (P < 0.05) compared with urea alone. However, a significant 11-17% improvement in REN with Limus was observed at QZ. The use of urea-N plus Limus would permit a reduction in N applications of 55-60% compared to farmers’ practice and/or further 20% N saving compared with optimized urea-N rate (150 kg N ha-1, based on N requirement by target yield of 7.5 t ha-1), and would achieve the same maize yields but with significantly decreased NH3 loss and increased N utilization.

  14. Urea enhances cell lysis of Schizosaccharomyces pombe ura4 mutants.

    PubMed

    Nishino, Kohei; Kushima, Misaki; Kaino, Tomohiro; Matsuo, Yasuhiro; Kawamukai, Makoto

    2017-07-01

    Cell lysis is induced in Schizosaccharomyces pombe ∆ura4 cells grown in YPD medium, which contains yeast extract, polypeptone, and glucose. To identify the medium components that induce cell lysis, we first tested various kinds of yeast extracts from different suppliers. Cell lysis of ∆ura4 cells on YE medium was observed when yeast extracts from OXOID, BD, Oriental, and Difco were used, but not when using yeast extract from Kyokuto. To determine which compounds induced cell lysis, we subjected yeast extract and polypeptone to GC-MS analysis. Ten kinds of compounds were detected in OXOID and BD yeast extracts, but not in Kyokuto yeast extract. Among them was urea, which was also present in polypeptone, and it clearly induced cell lysis. Deletion of the ure2 gene, which is responsible for utilizing urea, abolished the lytic effect of urea. The effect of urea was suppressed by deletion of pub1, and a similar phenotype was observed in the presence of polypeptone. Thus, urea is an inducer of cell lysis in S. pombe ∆ura4 cells.

  15. Effect of Time-of-Flight Information on PET/MR Reconstruction Artifacts: Comparison of Free-breathing versus Breath-hold MR-based Attenuation Correction.

    PubMed

    Delso, Gaspar; Khalighi, Mohammed; Ter Voert, Edwin; Barbosa, Felipe; Sekine, Tetsuro; Hüllner, Martin; Veit-Haibach, Patrick

    2017-01-01

    Purpose To evaluate the magnitude and anatomic extent of the artifacts introduced on positron emission tomographic (PET)/magnetic resonance (MR) images by respiratory state mismatch in the attenuation map. Materials and Methods The method was tested on 14 patients referred for an oncologic examination who underwent PET/MR imaging. The acquisition included standard PET and MR series for each patient, and an additional attenuation correction series was acquired by using breath hold. PET data were reconstructed with and without time-of-flight (TOF) information, first by using the standard free-breathing attenuation map and then again by using the additional breath-hold map. Two-tailed paired t testing and linear regression with 0 intercept was performed on TOF versus non-TOF and free-breathing versus breath-hold data for all detected lesions. Results Fluorodeoxyglucose-avid lesions were found in eight of the 14 patients included in the study. The uptake differences (maximum standardized uptake values) between PET reconstructions with free-breathing versus breath-hold attenuation ranged, for non-TOF reconstructions, from -18% to 26%. The corresponding TOF reconstructions yielded differences from -15% to 18%. Conclusion TOF information was shown to reduce the artifacts caused at PET/MR by respiratory mismatch between emission and attenuation data. © RSNA, 2016 Online supplemental material is available for this article.

  16. Urea encapsulation in modified starch matrix for nutrients retention

    NASA Astrophysics Data System (ADS)

    Naz, Muhammad Yasin; Sulaiman, Shaharin Anwar; Ariff, Mohd. Hazwan Bin Mohd.; Ariwahjoedi, Bambang

    2014-10-01

    It has been estimated that 20-70% of the used urea goes to the environment via leaching, nitrification and volatilization which not only harms the environment but also reduces the urea efficiency. By coating the urea granules, the farmers can achieve high urea performance through controlling the excess release of nitrogen. Up until now, different materials have been tested for nutrients retention. However, most of them are either expensive or unfriendly to the environment. Being cheap and biodegradable materials, the starches may also be used to coat the urea fertilizer for controlling the nutrients release. However, the pure starches do not meet the standards set by many industrial processes due to their slow tacking and too low viscosities and should be modified for getting smooth, compact and mechanically stronger coatings. In these studies, the tapioca starch was modified by reacting it with urea and different masses of borax. The prepared solutions were used to coat the urea granules of 3.45 mm average diameter. Different volumes (1, 1.5 and 2 mL) of each solution were used to coat 30 g of urea fluidized above the minimum level of fluidization. It was noticed that the coating thickness, percent coating, dissolution rate and percent release follow an increasing trend with an increase of solution volume; however, some random results were obtained while investigating the solution volume effects on the percent release. It was seen that the nutrients percent release over time increases with an increase in solution volume from 1 to 1.5 mL and thereafter reaches to a steady state. It confirms that the 1.5 mL of solution for 30 g urea samples will give the optimized coating results.

  17. Does postprandial itopride intake affect the rate of gastric emptying? A crossover study using the continuous real time 13C breath test (BreathID system).

    PubMed

    Nonaka, Takashi; Kessoku, Takaomi; Ogawa, Yuji; Yanagisawa, Shogo; Shiba, Tadahiko; Sahaguchi, Takashi; Atsukawa, Kazuhiro; Takahashi, Hisao; Sekino, Yusuke; Iida, Hiroshi; Hosono, Kunihiro; Endo, Hiroki; Sakamoto, Yasunari; Koide, Tomoko; Takahashi, Hirokazu; Tokoro, Chikako; Abe, Yasunobu; Maeda, Shin; Nakajima, Atsushi; Inamori, Masahiko

    2011-01-01

    The aim of this study was to determine whether oral Itopride hydrochloride (itopride) intake might have any effect on the rate of gastric emptying, using a novel non-invasive technique for measuring the rate of gastric emptying, namely, the continuous real time 13C breath test (BreathID system: Exalenz Bioscience Ltd., Israel). Eight healthy male volunteers participated in this randomized, two-way crossover study. The subjects fasted overnight and were randomly assigned to receive 50mg itopride following a test meal (200 kcal per 200mL, containing 100mg 13C acetate), or the test meal alone. Under both conditions, gastric emptying was monitored for 4 hours after administration of the test meal by the 13C-acetic acid breath test performed continually using the BreathID system. Using Oridion Research Software (beta version), the time required for emptying of 50% of the labeled meal (T 1/2), the analog to the scintigraphy lag time for 10% emptying of the labeled meal (T lag), the gastric emptying coefficient (GEC), and the regression-estimated constants (beta and kappa) were calculated. The parameters measured under the two conditions were compared using the Wilcoxon's signed-rank test. No significant differences in the calculated parameters, namely, the T 1/2, T lag, GEC, beta or kappa, were observed between the two test conditions, namely, administration of a test meal+itopride and administration of the test meal alone. The present study revealed that postprandial itopride intake had no significant influence on the rate of gastric emptying. Recently, several studies have shown that itopride may be effective in the treatment of patients with functional dyspepsia. Our results suggest that the efficacy of itopride in patients with functional dyspepsia may be based on its effect of improving functions other than the rate of gastric emptying, such as the activities at neuronal sites, brain-gut correlation, visceral hypersensitivity, gastric accommodation and distension-induced adaptation.

  18. Detection of flow limitation in obstructive sleep apnea with an artificial neural network.

    PubMed

    Norman, Robert G; Rapoport, David M; Ayappa, Indu

    2007-09-01

    During sleep, the development of a plateau on the inspiratory airflow/time contour provides a non-invasive indicator of airway collapsibility. Humans recognize this abnormal contour easily, and this study replicates this with an artificial neural network (ANN) using a normalized shape. Five 10 min segments were selected from each of 18 sleep records (respiratory airflow measured with a nasal cannula) with varying degrees of sleep disordered breathing. Each breath was visually scored for shape, and breaths split randomly into a training and test set. Equally spaced, peak amplitude normalized flow values (representing breath shape) formed the only input to a back propagation ANN. Following training, breath-by-breath agreement of the ANN with the manual classification was tabulated for the training and test sets separately. Agreement of the ANN was 89% in the training set and 70.6% in the test set. When the categories of 'probably normal' and 'normal', and 'probably flow limited' and 'flow limited' were combined, the agreement increased to 92.7% and 89.4% respectively, similar to the intra- and inter-rater agreements obtained by a visual classification of these breaths. On a naive dataset, the agreement of the ANN to visual classification was 57.7% overall and 82.4% when the categories were collapsed. A neural network based only on the shape of inspiratory airflow succeeded in classifying breaths as to the presence/absence of flow limitation. This approach could be used to provide a standardized, reproducible and automated means of detecting elevated upper airway resistance.

  19. Tenth anniversary special issue of the Journal of Breath Research: looking forward

    EPA Science Inventory

    The Journal of Breath Research has now reached its 10th anniversary of publication. From the general public’s perspective, breath analysis had always revolved around drinking and driving, and to some lesser extent pulmonary function testing of athletes. However, at the ince...

  20. 46 CFR 197.450 - Breathing gas tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... taken at the connection point to the distribution system— (1) Every 6 months; and (2) After every repair or modification. (b) Purchased supplies of breathing mixtures supplied to a diver are checked before... commencement of diving operations, at the umbilical or underwater breathing apparatus connection point for the...

  1. Urea biosensor for hemodialysis monitoring

    DOEpatents

    Glass, Robert S.

    1999-01-01

    An electrochemical sensor capable of detecting and quantifying urea in fluids resulting from hemodialysis procedures. The sensor is based upon measurement of the pH change produced in an aqueous environment by the products of the enzyme-catalyzed hydrolysis of urea. The sensor may be fabricated using methods amenable to mass fabrication, resulting in low-cost sensors and thus providing the potential for disposable use. In a typical application, the sensor could be used in treatment centers, in conjunction with an appropriate electronics/computer system, in order to determine the hemodialysis endpoint. The sensor can also be utilized to allow at-home testing to determine if dialysis was necessary. Such a home monitor is similar, in principle, to devices used for blood glucose testing by diabetics, and would require a blood droplet sample by using a finger prick.

  2. Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications

    PubMed Central

    Lourenço, Célia; Turner, Claire

    2014-01-01

    Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. “Breath fingerprinting”, indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles. PMID:24957037

  3. Breath analysis in disease diagnosis: methodological considerations and applications.

    PubMed

    Lourenço, Célia; Turner, Claire

    2014-06-20

    Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. "Breath fingerprinting", indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles.

  4. 42 CFR 84.96 - Service time test; closed-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Service time test; closed-circuit apparatus. 84.96...-Contained Breathing Apparatus § 84.96 Service time test; closed-circuit apparatus. (a) The closed-circuit apparatus will be classified according to the length of time it supplies adequate breathing gas to the...

  5. 42 CFR 84.96 - Service time test; closed-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Service time test; closed-circuit apparatus. 84.96...-Contained Breathing Apparatus § 84.96 Service time test; closed-circuit apparatus. (a) The closed-circuit apparatus will be classified according to the length of time it supplies adequate breathing gas to the...

  6. Comparing the effect of nitrate and urea enrichment on oligotrophic phytoplankton assemblages

    NASA Astrophysics Data System (ADS)

    Harrison, D. P.

    2014-12-01

    It has been speculated in the literature that "… urea enrichment would preferentially lead to the enhanced production of cyanobacteria, picoeukaryotes, and dinoflagellates, rather than diatoms." (Gilbert et al. 2010). Urea is the most manufactured chemical in the world (160 M tonnes p.a.) and the majority will eventually find its way into the marine environment, potentially contributing an annual nitrogen loading equivalent to 5% of New Primary Production (N), important global ramifications are to be expected if the hypothesis above is correct. The hypothesis was tested by enriching oligotrophic water samples collected from the Port Hacking National Reference Station, Australia with urea and nitrate in repeated experiments over an annual cycle during 2013. Biomass increased in all experiments, and had a higher incidence of diatoms to dinoflagellates in all experiments, with no significant difference between treatments for diatom cell count. In two instances dinoflagellate cell counts were significantly higher in nitrate treatments than in urea treatments, with no significant difference for the remaining experiments. The evidence does not support the hypothesis that urea preferentially leads to the production of dinoflagellates rather than diatoms when compared with nitrate enrichment. In this presentation I will examine and compare the effects of nitrate and urea enrichment on natural oligotrophic assembledges of phytoplankton, under laboratory conditions.

  7. Effect of an ntrC mutation on amino acid or urea utilization and on nitrogenase switch-off in Herbaspirillum seropedicae.

    PubMed

    Gusso, Claudio L; de Souza, Emanuel M; Rigo, Liu Un; de Oliveira Pedrosa, Fábio; Yates, M G; de M Rego, Fabiane G; Klassen, Giseli

    2008-03-01

    Herbaspirillum seropedicae is a nitrogen-fixing bacterium that grows well with ammonium chloride or sodium nitrate as alternative single nitrogen sources but that grows more slowly with L-alanine, L-serine, L-proline, or urea. The ntrC mutant strain DCP286A was able to utilize only ammonium or urea of these nitrogen sources. The addition of 1 mmol.L-1 ammonium chloride to the nitrogen-fixing wild-type strain inhibited nitrogenase activity rapidly and completely. Urea was a less effective inhibitor; approximately 20% of nitrogenase activity remained 40 min after the addition of 1 mmol x L-1 urea. The effect of the ntrC mutation on nitrogenase inhibition (switch-off) was studied in strain DCP286A containing the constitutively expressed gene nifA of H. seropedicae. In this strain, nitrogenase inhibition by ammonium was completely abolished, but the addition of urea produced a reduction in nitrogenase activity similar to that of the wild-type strain. The results suggest that the NtrC protein is required for assimilation of nitrate and the tested amino acids by H. seropedicae. Furthermore, NtrC is also necessary for ammonium-induced switch-off of nitrogenase but is not involved in the mechanism of nitrogenase switch-off by urea.

  8. Nitrification of archaeal ammonia oxidizers in acid soils is supported by hydrolysis of urea

    PubMed Central

    Lu, Lu; Han, Wenyan; Zhang, Jinbo; Wu, Yucheng; Wang, Baozhan; Lin, Xiangui; Zhu, Jianguo; Cai, Zucong; Jia, Zhongjun

    2012-01-01

    The hydrolysis of urea as a source of ammonia has been proposed as a mechanism for the nitrification of ammonia-oxidizing bacteria (AOB) in acidic soil. The growth of Nitrososphaera viennensis on urea suggests that the ureolysis of ammonia-oxidizing archaea (AOA) might occur in natural environments. In this study, 15N isotope tracing indicates that ammonia oxidation occurred upon the addition of urea at a concentration similar to the in situ ammonium content of tea orchard soil (pH 3.75) and forest soil (pH 5.4) and was inhibited by acetylene. Nitrification activity was significantly stimulated by urea fertilization and coupled well with abundance changes in archaeal amoA genes in acidic soils. Pyrosequencing of 16S rRNA genes at whole microbial community level demonstrates the active growth of AOA in urea-amended soils. Molecular fingerprinting further shows that changes in denaturing gradient gel electrophoresis fingerprint patterns of archaeal amoA genes are paralleled by nitrification activity changes. However, bacterial amoA and 16S rRNA genes of AOB were not detected. The results strongly suggest that archaeal ammonia oxidation is supported by hydrolysis of urea and that AOA, from the marine Group 1.1a-associated lineage, dominate nitrification in two acidic soils tested. PMID:22592820

  9. Nitrification of archaeal ammonia oxidizers in acid soils is supported by hydrolysis of urea.

    PubMed

    Lu, Lu; Han, Wenyan; Zhang, Jinbo; Wu, Yucheng; Wang, Baozhan; Lin, Xiangui; Zhu, Jianguo; Cai, Zucong; Jia, Zhongjun

    2012-10-01

    The hydrolysis of urea as a source of ammonia has been proposed as a mechanism for the nitrification of ammonia-oxidizing bacteria (AOB) in acidic soil. The growth of Nitrososphaera viennensis on urea suggests that the ureolysis of ammonia-oxidizing archaea (AOA) might occur in natural environments. In this study, (15)N isotope tracing indicates that ammonia oxidation occurred upon the addition of urea at a concentration similar to the in situ ammonium content of tea orchard soil (pH 3.75) and forest soil (pH 5.4) and was inhibited by acetylene. Nitrification activity was significantly stimulated by urea fertilization and coupled well with abundance changes in archaeal amoA genes in acidic soils. Pyrosequencing of 16S rRNA genes at whole microbial community level demonstrates the active growth of AOA in urea-amended soils. Molecular fingerprinting further shows that changes in denaturing gradient gel electrophoresis fingerprint patterns of archaeal amoA genes are paralleled by nitrification activity changes. However, bacterial amoA and 16S rRNA genes of AOB were not detected. The results strongly suggest that archaeal ammonia oxidation is supported by hydrolysis of urea and that AOA, from the marine Group 1.1a-associated lineage, dominate nitrification in two acidic soils tested.

  10. A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management

    PubMed Central

    Jiang, Chenyu; Sun, Meixiu; Wang, Zhennan; Chen, Zhuying; Zhao, Xiaomeng; Yuan, Yuan; Li, Yingxin; Wang, Chuji

    2016-01-01

    Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no “best-practice method” for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T2D subjects, and healthy subjects. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone, under a specifically controlled condition fast (<1 min) and portable breath acetone measurement can be used for screening abnormal metabolic status including diabetes, for point-of-care monitoring status of ketone bodies which have the signature smell of breath acetone, and for breath acetone related clinical studies requiring a large number of tests. PMID:27483281

  11. A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management.

    PubMed

    Jiang, Chenyu; Sun, Meixiu; Wang, Zhennan; Chen, Zhuying; Zhao, Xiaomeng; Yuan, Yuan; Li, Yingxin; Wang, Chuji

    2016-07-30

    Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no "best-practice method" for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T2D subjects, and healthy subjects. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone, under a specifically controlled condition fast (<1 min) and portable breath acetone measurement can be used for screening abnormal metabolic status including diabetes, for point-of-care monitoring status of ketone bodies which have the signature smell of breath acetone, and for breath acetone related clinical studies requiring a large number of tests.

  12. Mathematical and statistical approaches for interpreting biomarker compounds in exhaled human breath

    EPA Science Inventory

    The various instrumental techniques, human studies, and diagnostic tests that produce data from samples of exhaled breath have one thing in common: they all need to be put into a context wherein a posed question can actually be answered. Exhaled breath contains numerous compoun...

  13. A Greenhouse Assay on the Effect of Applied Urea Amount on the Rhizospheric Soil Bacterial Communities.

    PubMed

    Shang, Shuanghua; Yi, Yanli

    2015-12-01

    The rhizospheric bacteria play key role in plant nutrition and growth promotion. The effects of increased nitrogen inputs on plant rhizospheric soils also have impacted on whole soil microbial communities. In this study, we analyzed the effects of applied nitrogen (urea) on rhizospheric bacterial composition and diversity in a greenhouse assay using the high-throughput sequencing technique. To explore the environmental factors driving the abundance, diversity and composition of soil bacterial communities, the relationship between soil variables and the bacterial communities were also analyzed using the mantel test as well as the redundancy analysis. The results revealed significant bacterial diversity changes at different amounts of applied urea, especially between the control treatment and the N fertilized treatments. Mantel tests showed that the bacterial communities were significantly correlated with the soil nitrate nitrogen, available nitrogen, soil pH, ammonium nitrogen and total organic carbon. The present study deepened the understanding about the rhizospheric soil microbial communities under different amounts of applied urea in greenhouse conditions, and our work revealed the environmental factors affecting the abundance, diversity and composition of rhizospheric bacterial communities.

  14. Breath Test Refusals and Their Effect on DWI Prosecution

    DOT National Transportation Integrated Search

    2012-07-01

    This report describes the design and results of a project aimed at estimating the rate that drivers : refuse to submit to a legally-requested breath alcohol concentration test, and the effect of such : refusals on the prosecution of DWI cases. The st...

  15. Performance evaluation : balloon-type breath alcohol self tester for personal use

    DOT National Transportation Integrated Search

    1984-01-01

    The accuracy of the only breath alcohol balloon-type self test device being marketed for personal use (Luckey Laboratories DM-2) was assessed in the laboratory. Data regarding this self-test device's ability to accurately classify an individual as ha...

  16. Inward contaminant leakage tests of the S-Tron Corporation emergency escape breathing device.

    DOT National Transportation Integrated Search

    1992-04-01

    At the request of S-Tron Corporation, to support their contract with the U.S. Navy, performance tests of the Emergency Escape Breathing Device (EEBD) were conducted in the Environmental Physiology Research Section contaminant leakage chamber. Sulfur ...

  17. A study of characteristics of a reliable and practical breath alcohol screening test. Part A

    DOT National Transportation Integrated Search

    1975-08-01

    The objectives of this study were (1) to investigate several commercially available breath-alcohol screening test devices of the length-of-stain type, under standardized laboratory conditions, with respect to their ability satisfactorily to detect an...

  18. The elevated serum urea:creatinine ratio in canine babesiosis in South Africa is not of renal origin.

    PubMed

    de Scally, M P; Leisewitz, A L; Lobetti, R G; Thompson, P N

    2006-12-01

    Pigmented serum, usually due to free haemoglobin and/or bilirubin, is a common finding in dogs with babesiosis, resulting in interference with all biochemical tests that rely on photochemistry. This is particularly true of urea and creatinine determinations, complicating the diagnosis of acute renal failure, which is a serious complication of babesiosis. A disproportionately raised serum urea concentration of unknown origin occurs in severely anaemic canine babesiosis patients and gives rise to an increased serum urea:creatinine ratio. The assay for cystatin-C, an excellent measure of glomerular filtration rate, is unaffected by free serum haemoglobin, and due to its different intrinsic origins, is free of influence by the metabolic derangements and organ pathology, other than renal disease, encountered in canine babesiosis. Serum cystatin-C was used to compare the concentrations of serum urea and serum creatinine in dogs with the severely anaemic form of canine babesiosis as well as a canine babesiosis-free reference group. Mean serum urea and mean serum urea:creatinine ratio were significantly elevated in the babesia-infected group relative to the reference population in this study. Mean serum creatinine and mean serum cystatin-C were within the reference ranges. Therefore an elevated urea:creatinine ratio in canine babesiosis in the presence of a normal serum creatinine concentration is considered to be caused by an elevated serum urea concentration and is most likely of non-renal origin. Serum creatinine was therefore as specific a measure of renal function as serum cystatin-C in canine babesiosis in this study. The sensitivity of serum creatinine as a measure of renal function was not established by this study. Serum urea, however, proved to be of little use compared to serum cystatin-C and serum creatinine. Serum urea should therefore not be used to diagnose renal failure in canine babesiosis.

  19. The Effects of Acute Copper and Ammonia Challenges on Ammonia and Urea Excretion by the Blue Crab Callinectes sapidus.

    PubMed

    Zimmer, Alex M; Jorge, Marianna Basso; Wood, Chris M; Martins, Camila M G; Bianchini, Adalto

    2017-04-01

    Copper (Cu) is a persistent environmental contaminant that elicits several physiological disturbances in aquatic organisms, including a disruption in ammonia regulation. We hypothesized that exposure to Cu in a model crustacean (blue crab, Callinectes sapidus) acclimated to brackish water (2 ppt) would lead to hyperammonemia by stimulating an increase in ammonia production and/or by inhibiting ammonia excretion. We further hypothesized that urea production would represent an ammonia detoxification strategy in response to Cu. In a pilot experiment, exposure to 0, 100, and 200 µg/L Cu for 6 h caused significant concentration-dependent increases in ammonia excretion (J amm ). Based on these results, an acute 24-h 100 µg/L Cu exposure was conducted and this similarly caused an overall stimulation of J amm during the 24-h period, indicative of an increase in ammonia production. Terminal haemolymph total ammonia content (T amm ) was unchanged, suggesting that while ammonia production was increased, there was no inhibition of the excretion mechanism. In support of our second hypothesis, urea excretion (J urea ) increased in response to Cu exposure; haemolymph [urea] was unaffected. This suggested that urea production also was increased. To further test the hypothesis that J urea increased to prevent hyperammonemia during Cu exposure, crabs were exposed to high environmental ammonia (HEA; 2.5 mmol/L NH 4 HCO 3 ) for 12 h in a separate experiment. This led to a fourfold increase in haemolymph T amm , whereas J urea increased only transiently and haemolymph [urea] was unchanged, indicating that urea production likely does not contribute to the attenuation of hyperammonemia in blue crabs. Overall, Cu exposure in blue crabs led to increased ammonia and urea production, which were both eliminated by excretion. These results may have important implications in aquaculture systems where crabs may be exposed to elevated Cu and/or ammonia.

  20. Blinded Validation of Breath Biomarkers of Lung Cancer, a Potential Ancillary to Chest CT Screening

    PubMed Central

    Phillips, Michael; Bauer, Thomas L.; Cataneo, Renee N.; Lebauer, Cassie; Mundada, Mayur; Pass, Harvey I.; Ramakrishna, Naren; Rom, William N.; Vallières, Eric

    2015-01-01

    Background Breath volatile organic compounds (VOCs) have been reported as biomarkers of lung cancer, but it is not known if biomarkers identified in one group can identify disease in a separate independent cohort. Also, it is not known if combining breath biomarkers with chest CT has the potential to improve the sensitivity and specificity of lung cancer screening. Methods Model-building phase (unblinded): Breath VOCs were analyzed with gas chromatography mass spectrometry in 82 asymptomatic smokers having screening chest CT, 84 symptomatic high-risk subjects with a tissue diagnosis, 100 without a tissue diagnosis, and 35 healthy subjects. Multiple Monte Carlo simulations identified breath VOC mass ions with greater than random diagnostic accuracy for lung cancer, and these were combined in a multivariate predictive algorithm. Model-testing phase (blinded validation): We analyzed breath VOCs in an independent cohort of similar subjects (n = 70, 51, 75 and 19 respectively). The algorithm predicted discriminant function (DF) values in blinded replicate breath VOC samples analyzed independently at two laboratories (A and B). Outcome modeling: We modeled the expected effects of combining breath biomarkers with chest CT on the sensitivity and specificity of lung cancer screening. Results Unblinded model-building phase. The algorithm identified lung cancer with sensitivity 74.0%, specificity 70.7% and C-statistic 0.78. Blinded model-testing phase: The algorithm identified lung cancer at Laboratory A with sensitivity 68.0%, specificity 68.4%, C-statistic 0.71; and at Laboratory B with sensitivity 70.1%, specificity 68.0%, C-statistic 0.70, with linear correlation between replicates (r = 0.88). In a projected outcome model, breath biomarkers increased the sensitivity, specificity, and positive and negative predictive values of chest CT for lung cancer when the tests were combined in series or parallel. Conclusions Breath VOC mass ion biomarkers identified lung cancer in a separate independent cohort, in a blinded replicated study. Combining breath biomarkers with chest CT could potentially improve the sensitivity and specificity of lung cancer screening. Trial Registration ClinicalTrials.gov NCT00639067 PMID:26698306

  1. Management of Helicobacter pylori infection--a Working Party Report of the Malaysian Society of Gastroenterology and Hepatology.

    PubMed

    Goh, K L; Mahendra Raj, S; Parasakthi, N; Kew, S T; Kandasami, P; Mazlam, Z

    1998-09-01

    The Working Party Report on the Management of Helicobacter pylori serves as a clinical practice guideline for Malaysian doctors. H. pylori is not uncommon in the Malaysian population. Marked racial differences and the consistently low prevalence rates amongst Malays are noted. The working party recommends that if endoscopy is to be performed, a rapid urease test should be used for diagnosis. Where suspicion of the infection is strong and the urease test is negative, histology should be performed on gastric biopsies. Culture should be used to monitor resistance patterns to antibiotics and regional laboratories should assume this responsibility. The urea breath tests are highly accurate tests for diagnosis of H. pylori but is as yet not widely available in Malaysia. The working party strongly recommends that all peptic ulcer patients infected with H. pylori whether active, in remission and complicated ulcers should be treated for the infection. Patients with low-grade gastric mucosal lymphoid tissue lymphoma should also be treated for H. pylori infection. It is considered advisable that patients on long term nonsteroidal antinflammatory drug (NSAID) treatment with a history of peptic ulcers or dyspepsia and patients following resection of early gastric cancer or those with a family history of gastric cancer should also be tested and treated for H. pylori. The working party recommends, as first line treatment a 7-day combination therapy of a proton pump inhibitor, clarithromycin and metronidazole or amoxicillin. High metronidazole resistance rates locally may adversely affect regimens containing the antibiotic. It should also be noted that regimens that yield lower eradication rates may result in higher long term expenditure.

  2. Follow-up of coeliac disease with the novel one-hour 13C-sorbitol breath test versus the H2-sorbitol breath test.

    PubMed

    Tveito, Kari; Hetta, Anne Kristine; Askedal, Mia; Brunborg, Cathrine; Sandvik, Leiv; Løberg, Else Marit; Skar, Viggo

    2011-07-01

    We recently developed a (13)C-sorbitol breath test ((13)C-SBT) as an alternative to the H(2)-sorbitol breath test (H(2)-SBT) for coeliac disease. In this study we compared the diagnostic properties of the H(2)-SBT and the (13)C-SBT in follow-up of coeliac disease. Twenty-seven coeliac patients on a gluten-free diet (GFD) performed the breath tests. All had been tested before treatment in the initial study of the (13)C-SBT, in which 39 untreated coeliac patients, 40 patient controls, and 26 healthy volunteers participated. Five gram sorbitol and 100 mg (13)C-sorbitol were dissolved in 250 ml tap water and given orally. H(2), CH(4) and (13)CO(2) were measured in end-expiratory breath samples every 30 min for 4 h. Increased H(2) concentration ≥20 ppm from basal values was used as cut-off for the H(2)-SBT. Sixty minutes values were used as diagnostic index in the (13)C-SBT. (13)CO(2) levels at 60 min increased in 20/26 treated coeliac patients (77%) after GFD, but were significantly lower than in control groups. Out of 20 patients who had a positive H(2)-SBT before GFD, 12 had a negative H(2)-SBT after GFD. Peak H(2) concentrations were not correlated with (13)C-SBT results. The study confirms the sensitivity of a one-hour (13)C-SBT for small intestinal malabsorption. The (13)C-SBT has superior diagnostic properties compared with the H(2)-SBT in follow-up of coeliac disease.

  3. 49 CFR 40.245 - What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a breath tube ASD? (a) As the STT or BAT, you must take the following steps when using the saliva... ATF. (b) As the STT or BAT, you must take the following steps when using the breath tube ASD: (1... the manufacturer's directions. (11) You must note the fact that you used a breath tube device in Step...

  4. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    NASA Astrophysics Data System (ADS)

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-06-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange.

  5. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    PubMed Central

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-01-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange. PMID:27311826

  6. Design and testing of an independently controlled urea SCR retrofit system for the reduction of NOx emissions from marine diesels.

    PubMed

    Johnson, Derek R; Bedick, Clinton R; Clark, Nigel N; McKain, David L

    2009-05-15

    Diesel engine emissions for on-road, stationary and marine applications are regulated in the United States via standards set by the Environmental Protection Agency (EPA). A major component of diesel exhaust that is difficult to reduce is nitrogen oxides (NOx). Selective catalytic reduction (SCR) has been in use for many years for stationary applications, including external combustion boilers, and is promising for NOx abatement as a retrofit for mobile applications where diesel compression ignition engines are used. The research presented in this paper is the first phase of a program focused on the reduction of NOx by use of a stand-alone urea injection system, applicable to marine diesel engines typical of work boats (e.g., tugs). Most current urea SCR systems communicate with engine controls to predict NOx emissions based on signals such as torque and engine speed, however many marine engines in use still employ mechanical injection technology and lack electronic communication abilities. The system developed and discussed in this paper controls NOx emissions independentof engine operating parameters and measures NOx and exhaust flow using the following exhaust sensor inputs: absolute pressure, differential pressure, temperature, and NOx concentration. These sensor inputs were integrated into an independent controller and open loop architecture to estimate the necessary amount of urea needed, and the controller uses pulse width modulation (PWM) to power an automotive fuel injector for airless urea delivery. The system was tested in a transient test cell on a 350 hp engine certified at 4 g/bhp-hr of NOx, with a goal of reducing the engine out NOx levels by 50%. NOx reduction capabilities of 41-67% were shown on the non road transient cycle (NRTC) and ICOMIA E5 steady state cycles with system optimization during testing to minimize the dilute ammonia slip to cycle averages of 5-7 ppm. The goal of 50% reduction of NOx can be achieved dependent upon cycle. Further research with control optimization, urea distribution and possible use of oxidation catalysts is recommended to improve the NOx reduction capabilities while minimizing ammonia slip.

  7. Urea transport and clinical potential of urearetics.

    PubMed

    Klein, Janet D; Sands, Jeff M

    2016-09-01

    Urea is transported by urea transporter proteins in kidney, erythrocytes, and other tissues. Mice in which different urea transporters have been knocked out have urine-concentrating defects, which has led to the development and testing of urea transporters Slc14A2 (UT-A) and Slc14A1 (UT-B) inhibitors as urearetics. This review summarizes the knowledge gained during the past year on urea transporter regulation and investigations into the clinical potential of urearetics. UT-A1 undergoes several posttranslational modifications that increase its function by increasing UT-A1 accumulation in the apical plasma membrane. UT-A1 is phosphorylated by protein kinase A, exchange protein activated by cyclic AMP, protein kinase Cα, and AMP-activated protein kinase, all at different serine residues. UT-A1 is also regulated by 14-3-3, which contributes to UT-A1 removal from the membrane. UT-A1 is glycosylated with various glycan moieties in animal models of diabetes mellitus. Transgenic expression of UT-A1 into UT-A1/UT-A3 knockout mice restores urine-concentrating ability. UT-B is present in descending vasa recta and urinary bladder, and is linked to bladder cancer. Inhibitors of UT-A and UT-B have been developed that result in diuresis with fewer abnormalities in serum electrolytes than conventional diuretics. Urea transporters play critical roles in the urine-concentrating mechanism. Urea transport inhibitors are a promising new class of diuretic agent.

  8. Alternative E ammonia feedstock

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lentz, M.J.; Wright, R.A.

    1999-07-01

    Power plants are using more Ammonia for increasing precipitator and baghouse efficiency, for SCR and SNCR processes, and for controlling acid stack plumes and dewpoint corrosion. These simple systems inject ammonia and air into the furnace or the precipitator or baghouse inlet ductwork. The common feedstocks in use today are Anhydrous ammonia [NH{sub 3}] and Aqueous ammonia [NH{sub 4}OH], both defined as poison gases by US authorities and most Western nations. Storage and handling procedures for these products are strictly regulated. Wilhelm Environmental Technologies Inc. is developing use of solid, formed or prilled Urea [CO(NH{sub 2}){sub 2}] as the feedstock.more » When heated in moist air, Urea sublimes to ammonia [NH{sub 3}] and carbon dioxide [CO{sub 2}]. Urea is stored and handled without restrictions or environmental concerns. Urea is a more expensive feedstock than NH{sub 3}, but much less expensive than [NH{sub 4}OH]. The design, and operating results, of a pilot system at Jacksonville Electric St. John's River Plant [Unit 2] are described. The pilot plant successfully sublimed Urea up to 100 pounds/hour. Further testing is planned. Very large ammonia use may favor NH{sub 3}, but smaller quantities can be produced at attractive prices with Urea based ammonia systems. Storage costs are far less. Many fluidized-bed boilers can use pastille or solid urea metered directly into the existing cyclones for NO{sub x} control. This is more economical than aqueous ammonia or aqueous urea based technology.« less

  9. Cross-Reactivity of Polyclonal Antibodies against Canavalia ensiformis (Jack Bean) Urease and Helicobacter pylori Urease Subunit A Fragments.

    PubMed

    Kaminski, Zbigniew Jerzy; Relich, Inga; Konieczna, Iwona; Kaca, Wieslaw; Kolesinska, Beata

    2018-01-01

    Overlapping decapeptide fragments of H. pylori urease subunit A (UreA) were synthesized and tested with polyclonal antibodies against Canavalia ensiformis (Jack bean) urease. The linear epitopes of UreA identified using the dot blot method were then examined using epitope mapping. For this purpose, series of overlapping fragments of UreA, frameshifted ± four amino acid residues were synthesized. Most of the UreA epitopes which reacted with the Jack bean urease polyclonal antibodies had been recognized in previous studies by monoclonal antibodies against H. pylori urease. Fragments 11 - 24, 21 - 33, and 31 - 42 were able to interact with the Jack bean urease antibodies, giving stable immunological complexes. However, the lack of recognition by these antibodies of all the components in the peptide map strongly suggests that a non-continuous (nonlinear) epitope is located on the N-terminal domain of UreA. © 2018 Wiley-VHCA AG, Zurich, Switzerland.

  10. Stabilization of source-separated human urine by chemical oxidation.

    PubMed

    Zhang, Yang; Li, Zifu; Zhao, Yuan; Chen, Shuangling; Mahmood, Ibrahim Babatunde

    2013-01-01

    The inhibitory effect of ozone and hydrogen peroxide (HP) on urea hydrolysis in stored urine was investigated and compared. Ozone showed less effect on urea hydrolysis due to the complicated composition of urine (including a large amount of urease-producing bacteria) and bacteria regeneration. Ozone concentration and total heterotrophic bacteria analysis demonstrated that residual ozone concentration decreased by 43% within 15 hr from 13.50 to 7.72 mg/L in the one-time ozonation urine test, and finally completely decomposed within 4 days. In addition, bacteria regenerated quickly after ozone completely decomposed. However, HP showed a significant effect on inhibiting urea hydrolysis not only in stored urine but also in fecal-contaminated urine. The suitable doses of applied HP to inhibit urea hydrolysis in stored urine, concentrations of 0.5 and 1.0 g feces per liter of fecal-contaminated urine, were 0.03, 0.16 and 0.23 mol/L, respectively. The urea concentrations after 2 months stored were 7,145, 7,109 and 7,234 mg/L, respectively.

  11. How to deal with morning bad breath: A randomized, crossover clinical trial.

    PubMed

    Oliveira-Neto, Jeronimo M; Sato, Sandra; Pedrazzi, Vinícius

    2013-11-01

    The absence of a protocol for the treatment of halitosis has led us to compare mouthrinses with mechanical oral hygiene procedures for treating morning breath by employing a hand-held sulfide monitor. To compare the efficacy of five modalities of treatment for controlling morning halitosis in subjects with no dental or periodontal disease. This is a five-period, randomized, crossover clinical trial. Twenty volunteers were randomly assigned to the trial. Testing involved the use of a conventional tongue scraper, a tongue scraper joined to the back of a toothbrush's head, two mouthrinses (0.05% cetylpyridinium chloride and 0.12% chlorhexidine digluconate) and a soft-bristled toothbrush and fluoride toothpaste for practicing oral hygiene. Data analysis was performed using SPSS version 17 for Windows and NCSS 2007 software (P < 0.05). The products and the periods were compared with each other using the Friedman's test. When significant differences (P < 0.05) were determined, the products and periods were compared in pairs by using the Wilcoxon's test and by adjusting the original significance level (0.05) for multiple comparisons by using the Bonferroni's method. The toothbrush's tongue scraper was able to significantly reduce bad breath for up to 2 h. Chlorhexidine reduced bad breath only at the end of the second hour, an effect that lasted for 3 h. Mechanical tongue cleaning was able to immediately reduce bad breath for a short period, whereas chlorhexidine and mechanical oral hygiene reduced bad breath for longer periods, achieving the best results against morning breath.

  12. Determination of ethanol in breath for legal purposes using a five-filter infrared analyzer: studies on response to volatile interfering substances.

    PubMed

    Jones, Alan Wayne; Andersson, Lars

    2008-06-01

    The analysis of ethanol in exhaled breath is widely accepted and used worldwide for legal purposes to gather evidence of alcohol-impaired driving. Most evidential breath-alcohol instruments incorporate infrared (IR) spectroscopy as the analytical principle focusing on C-H or C-O stretching frequencies in ethanol molecules. The instrument approved for legal purposes in Sweden is called Evidenzer and is equipped with five infrared filters of which four are used for identification and quantification of ethanol and the fifth is a reference filter. The response of Evidenzer was tested against 21 volatile organic compounds (VOCs), and the instrument was programmed to deduct any bias caused by these VOCs if present in a sample of breath. If the amount deducted exceeds a certain threshold value, the entire test is aborted. Whenever this happens, the police request a specimen of venous blood for analysis by gas chromatography. Of a total of 24 072 drunken drivers, the evidential breath-alcohol test was aborted on 27 occasions (0.11%) because an interfering substance was present above the critical threshold. The VOCs most commonly identified in blood were acetone, isopropanol and/or methyl ethyl ketone (MEK). Elevated levels of acetone and isopropanol might arise during ketogenesis in people suffering from diabetes, or in those who eat low carbohydrate diets. High concentrations of acetone and MEK are probably caused by people drinking a technical alcohol product (T-Red), which is available in Sweden and is denatured with these agents. This study confirms that relatively few apprehended drivers in Sweden have elevated concentrations of VOCs in breath other than ethanol. Even the aborted breath tests, to a large extent, contained ethanol above the legal limit for driving.

  13. Breathing efficiency during inspiratory threshold loading in patients with chronic obstructive pulmonary disease.

    PubMed

    Baarends, E M; Schols, A M; Nusmeier, C M; van der Grinten, C P; Wouters, E F

    1998-05-01

    Patients with chronic obstructive pulmonary disease (COPD) demonstrate an increased oxygen cost of breathing. It is as yet unclear whether this is related to a decreased breathing efficiency. The aim of the present study was to compare breathing efficiency in 16 patients with COPD (11 men, five women) and 16 healthy elderly subjects (seven men, nine women), and to investigate a possible relationship between breathing efficiency and resting energy expenditure (REE). REE was measured using a ventilated hood system. Breathing efficiency was assessed by measuring oxygen consumption (V'O2), mean inspiratory mouth pressure (MIP) and flow during breathing at rest and subsequently during breathing against an inspiratory threshold (40% of maximal inspiratory pressure). During loaded breathing there was a significant increase in V'O2, MIP, and external work of breathing compared with unloaded breathing in both groups. As intended, ventilation did not increase significantly during the breathing efficiency test in the patients with COPD. The breathing efficiency (median, range) of the patients with COPD was similar (3.7%, 1.4-8.7%) to that of the healthy elderly subjects (3.2%, 1.7-8.3%). Breathing efficiency was not correlated with REE in either group. In the present study, in which dynamic hyperinflation was probably prevented, no difference in breathing efficiency was found between healthy elderly subjects and COPD patients when breathing against an external inspiratory threshold. Furthermore, breathing efficiency was not related to REE in both groups.

  14. Breath test refusals and DWI prosecution : traffic tech.

    DOT National Transportation Integrated Search

    2012-08-01

    There are typically about 1.4 million DWI (driving while : impaired) arrests each year in the United States. An officers : request to a driver for a breath (or blood, or urine) test is an : important part of the arrest process. The percentage of d...

  15. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2013-10-01 2013-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...

  16. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2012-10-01 2012-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...

  17. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2014-10-01 2014-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...

  18. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be measured with a breathing machine as described in § 84.88. (b) The open-circuit apparatus will be...

  19. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be measured with a breathing machine as described in § 84.88. (b) The open-circuit apparatus will be...

  20. Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements.

    PubMed

    Wang, Zhennan; Wang, Chuji

    2013-09-01

    Since the ancient discovery of the 'sweet odor' in human breath gas, pursuits of the breath analysis-based disease diagnostics have never stopped. Actually, the 'smell' of the breath, as one of three key disease diagnostic techniques, has been used in Eastern-Medicine for more than three thousand years. With advancement of measuring technologies in sensitivity and selectivity, more specific breath gas species have been identified and established as a biomarker of a particular disease. Acetone is one of the breath gases and its concentration in exhaled breath can now be determined with high accuracy using various techniques and methods. With the worldwide prevalence of diabetes that is typically diagnosed through blood testing, human desire to achieve non-blood based diabetic diagnostics and monitoring has never been quenched. Questions, such as is breath acetone a biomarker of diabetes and how is the breath acetone related to the blood glucose (BG) level (the golden criterion currently used in clinic for diabetes diagnostic, monitoring, and management), remain to be answered. A majority of current research efforts in breath acetone measurements and its technology developments focus on addressing the first question. The effort to tackle the second question has begun recently. The earliest breath acetone measurement in clearly defined diabetic patients was reported more than 60 years ago. For more than a half-century, as reviewed in this paper, there have been more than 41 independent studies of breath acetone using various techniques and methods, and more than 3211 human subjects, including 1581 healthy people, 242 Type 1 diabetic patients, 384 Type 2 diabetic patients, 174 unspecified diabetic patients, and 830 non-diabetic patients or healthy subjects who are under various physiological conditions, have been used in the studies. The results of the breath acetone measurements collected in this review support that many conditions might cause changes to breath acetone concentrations; however, the results from the six independent studies using clearly-defined Type 1 and Type 2 diabetic patients unanimously support that an elevated mean breath acetone concentration exists in Type 1 diabetes. Note that there is some overlap between the ranges of breath acetone concentration in individual T1D patients and healthy subjects; this reminds one to be careful when using an acetone breath test on T1D diagnostics. Comparatively, it is too early to draw a general conclusion on the relationship between a breath acetone level and a BG level from the very limited data in the literature.

  1. Analysis of Exhaled Breath for Disease Detection

    NASA Astrophysics Data System (ADS)

    Amann, Anton; Miekisch, Wolfram; Schubert, Jochen; Buszewski, Bogusław; Ligor, Tomasz; Jezierski, Tadeusz; Pleil, Joachim; Risby, Terence

    2014-06-01

    Breath analysis is a young field of research with great clinical potential. As a result of this interest, researchers have developed new analytical techniques that permit real-time analysis of exhaled breath with breath-to-breath resolution in addition to the conventional central laboratory methods using gas chromatography-mass spectrometry. Breath tests are based on endogenously produced volatiles, metabolites of ingested precursors, metabolites produced by bacteria in the gut or the airways, or volatiles appearing after environmental exposure. The composition of exhaled breath may contain valuable information for patients presenting with asthma, renal and liver diseases, lung cancer, chronic obstructive pulmonary disease, inflammatory lung disease, or metabolic disorders. In addition, oxidative stress status may be monitored via volatile products of lipid peroxidation. Measurement of enzyme activity provides phenotypic information important in personalized medicine, whereas breath measurements provide insight into perturbations of the human exposome and can be interpreted as preclinical signals of adverse outcome pathways.

  2. Gender Difference of Gastric Emptying in Healthy Volunteers and Patients with Functional Dyspepsia.

    PubMed

    Mori, Hideki; Suzuki, Hidekazu; Matsuzaki, Juntaro; Taniguchi, Kanami; Shimizu, Toshiyuki; Yamane, Tsuyoshi; Masaoka, Tatsuhiro; Kanai, Takanori

    2017-01-01

    Delayed gastric emptying is one of the reasons why functional dyspepsia (FD) occurs. The 13C-acetate breath test is widely used to evaluate gastric emptying. Nevertheless, the standard value of 13C-acetate breath test has not taken into account the gender difference of gastric emptying among healthy individuals. The main aim of this study was to readjust the standard value of 13C-acetate breath test in the light of gender differences. In addition, we clarified the prevalence and clinical characteristics of delayed gastric emptying in patients with FD using the modified standard values of 13C-acetate breath test. Fifty-two healthy individuals and 126 patients with patients with FD were enrolled. Gastric emptying was evaluated by the 13C-acetate breath test. The cut-off points of Tmax for the diagnosis of delayed gastric emptying were determined on the basis of results from healthy individuals making a distinction of genders. Gastroesophageal reflux symptoms, dyspeptic symptoms, scores of anxiety and depression, age, body mass index (BMI), smoking and alcohol consumption were compared between the delayed gastric emptying group and the non-delayed gastric emptying group. Since gastric emptying was delayed in healthy women compared with that in healthy men (Tmax, 53.6 ± 19.3 vs. 42.7 ± 16.9 min, p = 0.04), we set the cut-off points of Tmax at 60 min in men and at 75 min in women. In patients with FD, the prevalence of delayed gastric emptying was not different between men and women with the modified standard values of 13C-acetate breath test. (31.0 vs. 27.4%, p = 0.68). BMI was lower in the delayed gastric emptying group than in the non-delayed group among the male patients. Reflux symptoms were more severe in delayed gastric emptying group than in the non-delayed group among the female patients. The standard values of 13C-acetate breath test should be modified bearing the gender difference in mind. It provides us more appropriate information to understand the mechanisms of FD. © 2016 S. Karger AG, Basel.

  3. The accuracy of coin-operated breath analysers installed in licensed premises in the Perth metropolitan area.

    PubMed

    Hay, Greg; Cercarelli, L Rina

    2004-04-01

    To examine the accuracy of coin-operated breath analysers installed in licensed premises in the Perth metropolitan area. Two hundred licensed premises were contacted, which resulted in the location of 36 wall-mounted, coin-operated breath analysers. One instrument was removed prior to testing. These premises were then visited and the accuracy of the instruments was tested in situ using National Association of Testing Authorities Australia (NATA) certified 0.080% and 0.100% ethanol in nitrogen gas. The instruments were installed in the licensed premises as follows: 15 in the lounge bar, 10 in the main entrance, six in the public bar, two in the passageway to the toilets, and one in the male toilets. One licensed premise provided a handheld breath instrument. All instruments were accompanied by warning and operating instructions, but only five had any educational material. Only seven of the licensed premises had staff who had received any training in the operation of the wall-mounted instruments. Half of the licensees were unaware of the servicing requirements of the instruments. The testing found that only nine (25%) of the instruments provided acceptable results. The low level of accuracy of coin-operated breath analysers in the Perth metropolitan area is alarming and users should be informed of the potential inaccuracies. This paper, however, does not rule out that some wall-mounted breath analysing instruments may provide accurate results when properly maintained.

  4. Use of the single-breath method of estimating cardiac output during exercise-stress testing.

    NASA Technical Reports Server (NTRS)

    Buderer, M. C.; Rummel, J. A.; Sawin, C. F.; Mauldin, D. G.

    1973-01-01

    The single-breath cardiac output measurement technique of Kim et al. (1966) has been modified for use in obtaining cardiac output measurements during exercise-stress tests on Apollo astronauts. The modifications involve the use of a respiratory mass spectrometer for data acquisition and a digital computer program for data analysis. The variation of the modified method for triplicate steady-state cardiac output measurements was plus or minus 1 liter/min. The combined physiological and methodological variation seen during a set of three exercise tests on a series of subjects was 1 to 2.5 liter/min. Comparison of the modified method with the direct Fick technique showed that although the single-breath values were consistently low, the scatter of data was small and the correlation between the two methods was high. Possible reasons for the low single-breath cardiac output values are discussed.

  5. Voltammetric enzyme sensor for urea using mercaptohydroquinone-modified gold electrode as the base transducer.

    PubMed

    Mizutani, F; Yabuki, S; Sato, Y

    1997-01-01

    A voltammetric urea-sensing electrode was prepared by combining a lipid-attached urease layer with a 2,5-dihydroxythiophenol-modified gold electrode. A self-assembled monolayer of dihydroxythiophenol was prepared on the gold surface by soaking the electrode into an ethanolic solution containing the modifier. A layer of the lipid-attached enzyme and that of acetyl cellulose overcoat were successively made on the dihydroxythiophenol-modified electrode by applying a dip-coating procedure. The addition of urea in a test solution (10 mM phosphate buffer, pH 7.0) brought about an increase of pH near the urease layer. The pH shift accompanied a negative shift of the anodic peak, which corresponded to the electro-oxidation of dihydroxyphenol moiety to form quinone, on the linear sweep voltammograms for the urease/dihydroxythiophenol electrode. The concentration of urea (0.2-5 mM) could be determined by measuring the electrode current at -0.05 V versus Ag/AgCl from the voltammogram. The electrode was applied to the determination of urea in human urine; the measurement of electrode current at such a low potential provided the urea determination without any electrochemical interference from L-ascorbic acid and uric acid.

  6. Comparison of nitrogen utilization and urea kinetics between yaks (Bos grunniens) and indigenous cattle (Bos taurus).

    PubMed

    Zhou, J W; Zhong, C L; Liu, H; Degen, A A; Titgemeyer, E C; Ding, L M; Shang, Z H; Guo, X S; Qiu, Q; Li, Z P; Yang, G; Long, R J

    2017-10-01

    Under traditional management on the Qinghai-Tibetan Plateau, yaks () graze only on natural pasture without supplements and are forced to cope with sparse forage of low N content, especially in winter. In contrast, indigenous Tibetan yellow cattle () require supplements during the cold season. We hypothesized that, in response to harsh conditions, yaks cope with low N intakes better than cattle. To test this hypothesis, a study of whole-body N retention and urea kinetics was conducted in 2 concurrent 4 × 4 Latin squares, with 1 square using yaks and 1 square using cattle. Four isocaloric forage-concentrate diets differing in N concentrations (10.3, 19.5, 28.5, and 37.6 g N/kg DM) were formulated, and by design, DMI were similar between species and across diets. Urea kinetics were determined with continuous intravenous infusion of NN urea for 104 h, and total urine and feces were concomitantly collected. Urea production, urea recycling to the gut, and ruminal microbial protein synthesis all linearly increased ( < 0.001) with increasing dietary N in both yaks and cattle. Urinary N excretion was less ( = 0.04) and N retention was greater ( = 0.01) in yaks than in cattle. Urea production was greater in yaks than in cattle at the 3 lowest N diets but greater in cattle than in yaks at the highest N diet (species × diet, < 0.02). Urea N recycled to the gut ( < 0.001), recycled urea N captured by ruminal bacteria ( < 0.001), and ruminal microbial protein production ( = 0.05) were greater in yaks than in cattle. No more than 12% of urea recycling was through saliva, with no difference between species ( = 0.61). Glomerular filtration rate was lower ( = 0.05) in yaks than in cattle. The higher urea recycling and greater capture of recycled urea by ruminal microbes in yaks than in cattle suggest that yaks use mechanisms to utilize dietary N more efficiently than cattle, which may partially explain the better survival of yaks than cattle when fed low-N diets.

  7. Effect of upper costal and costo-diaphragmatic breathing types on electromyographic activity of respiratory muscles.

    PubMed

    Celhay, Isabel; Cordova, Rosa; Miralles, Rodolfo; Meza, Francisco; Erices, Pia; Barrientos, Camilo; Valenzuela, Saúl

    2015-04-01

    To compare electromyographic (EMG) activity in young-adult subjects with different breathing types. This study included 50 healthy male subjects with complete natural dentition, and no history of orofacial pain or craniomandibular-cervical-spinal disorders. Subjects were classified into two groups: upper costal breathing type, and costo-diaphragmatic breathing. Bipolar surface electrodes were located on sternocleidomastoid, diaphragm, external intercostal, and latissimus dorsi muscles. Electromyographic activity was recorded during the following tasks: (1) normal quiet breathing; (2) speaking the word 'Mississippi'; (3) swallowing saliva; and (4) forced deep breathing. Sternocleidomastoid and latissimus dorsi EMG activity was not significantly different between breathing types, whereas diaphragm and external intercostal EMG activity was significantly higher in the upper costal than costo-diaphragmatic breathing type in all tasks (P<0·05; Wilcoxon signed rank-sum test). Diaphragm and external intercostal EMG activity suggests that there could be differences in motor unit recruitment strategies depending on the breathing type.

  8. Increased oxygen load in the prefrontal cortex from mouth breathing: a vector-based near-infrared spectroscopy study.

    PubMed

    Sano, Masahiro; Sano, Sayaka; Oka, Noriyuki; Yoshino, Kayoko; Kato, Toshinori

    2013-12-04

    Individuals who habitually breathe through the mouth are more likely than nasal breathers to have sleep disorders and attention deficit hyperactive disorder. We hypothesized that brain hemodynamic responses in the prefrontal cortex might be different for mouth and nasal breathing. To test this hypothesis, we measured changes in oxyhemoglobin and deoxyhemoglobin in the prefrontal cortex during mouth breathing and nasal breathing in healthy adults (n=9) using vector-based near-infrared spectroscopy. The angle k, calculated from changes in oxyhemoglobin and deoxyhemoglobin and indicating the degree of oxygen exchange, was significantly higher during mouth breathing (P<0.05), indicating an increased oxygen load. Mouth breathing also caused a significant increase in deoxyhemoglobin, but oxyhemoglobin did not increase. This difference in oxygen load in the brain arising from different breathing routes can be evaluated quantitatively using vector-based near-infrared spectroscopy. Phase responses could help to provide an earlier and more reliable diagnosis of a patient's habitual breathing route than a patient interview.

  9. Increased oxygen load in the prefrontal cortex from mouth breathing: a vector-based near-infrared spectroscopy study

    PubMed Central

    Sano, Sayaka; Oka, Noriyuki; Yoshino, Kayoko; Kato, Toshinori

    2013-01-01

    Individuals who habitually breathe through the mouth are more likely than nasal breathers to have sleep disorders and attention deficit hyperactive disorder. We hypothesized that brain hemodynamic responses in the prefrontal cortex might be different for mouth and nasal breathing. To test this hypothesis, we measured changes in oxyhemoglobin and deoxyhemoglobin in the prefrontal cortex during mouth breathing and nasal breathing in healthy adults (n=9) using vector-based near-infrared spectroscopy. The angle k, calculated from changes in oxyhemoglobin and deoxyhemoglobin and indicating the degree of oxygen exchange, was significantly higher during mouth breathing (P<0.05), indicating an increased oxygen load. Mouth breathing also caused a significant increase in deoxyhemoglobin, but oxyhemoglobin did not increase. This difference in oxygen load in the brain arising from different breathing routes can be evaluated quantitatively using vector-based near-infrared spectroscopy. Phase responses could help to provide an earlier and more reliable diagnosis of a patient’s habitual breathing route than a patient interview. PMID:24169579

  10. Automatic Recognition of Breathing Route During Sleep Using Snoring Sounds

    NASA Astrophysics Data System (ADS)

    Mikami, Tsuyoshi; Kojima, Yohichiro

    This letter classifies snoring sounds into three breathing routes (oral, nasal, and oronasal) with discriminant analysis of the power spectra and k-nearest neighbor method. It is necessary to recognize breathing route during snoring, because oral snoring is a typical symptom of sleep apnea but we cannot know our own breathing and snoring condition during sleep. As a result, about 98.8% classification rate is obtained by using leave-one-out test for performance evaluation.

  11. Air-Breathing Ramjet Electric Propulsion for Controlling Low-Orbit Spacecraft Motion to Compensate for Aerodynamic Drag

    NASA Astrophysics Data System (ADS)

    Erofeev, A. I.; Nikiforov, A. P.; Popov, G. A.; Suvorov, M. O.; Syrin, S. A.; Khartov, S. A.

    2017-12-01

    Problems on designing the air-breathing ramjet electric propulsion thruster for controlling loworbit spacecraft motion are examined in the paper. Information for choosing orbits' altitudes for reasonable application of an air-breathing ramjet electric propulsion thruster and propellant exhaust velocity is presented. Estimates of the probable increase of gas concentration in the area of air-breathing ramjet ionization are presented. The test results of the thruster are also given.

  12. Prediction of breast cancer risk with volatile biomarkers in breath.

    PubMed

    Phillips, Michael; Cataneo, Renee N; Cruz-Ramos, Jose Alfonso; Huston, Jan; Ornelas, Omar; Pappas, Nadine; Pathak, Sonali

    2018-03-23

    Human breath contains volatile organic compounds (VOCs) that are biomarkers of breast cancer. We investigated the positive and negative predictive values (PPV and NPV) of breath VOC biomarkers as indicators of breast cancer risk. We employed ultra-clean breath collection balloons to collect breath samples from 54 women with biopsy-proven breast cancer and 124 cancer-free controls. Breath VOCs were analyzed with gas chromatography (GC) combined with either mass spectrometry (GC MS) or surface acoustic wave detection (GC SAW). Chromatograms were randomly assigned to a training set or a validation set. Monte Carlo analysis identified significant breath VOC biomarkers of breast cancer in the training set, and these biomarkers were incorporated into a multivariate algorithm to predict disease in the validation set. In the unsplit dataset, the predictive algorithms generated discriminant function (DF) values that varied with sensitivity, specificity, PPV and NPV. Using GC MS, test accuracy = 90% (area under curve of receiver operating characteristic in unsplit dataset) and cross-validated accuracy = 77%. Using GC SAW, test accuracy = 86% and cross-validated accuracy = 74%. With both assays, a low DF value was associated with a low risk of breast cancer (NPV > 99.9%). A high DF value was associated with a high risk of breast cancer and PPV rising to 100%. Analysis of breath VOC samples collected with ultra-clean balloons detected biomarkers that accurately predicted risk of breast cancer.

  13. Urea biosensor for hemodialysis monitoring

    DOEpatents

    Glass, R.S.

    1999-01-12

    This research discloses an electrochemical sensor capable of detecting and quantifying urea in fluids resulting from hemodialysis procedures. The sensor is based upon measurement of the pH change produced in an aqueous environment by the products of the enzyme-catalyzed hydrolysis of urea. The sensor may be fabricated using methods amenable to mass fabrication, resulting in low-cost sensors and thus providing the potential for disposable use. In a typical application, the sensor could be used in treatment centers, in conjunction with an appropriate electronics/computer system, in order to determine the hemodialysis endpoint. The sensor can also be utilized to allow at-home testing to determine if dialysis was necessary. Such a home monitor is similar, in principle, to devices used for blood glucose testing by diabetics, and would require a blood droplet sample by using a finger prick. 9 figs.

  14. Evaluation of innovative state and community alcohol projects : breath alcohol testing program effectiveness, impact and transferability

    DOT National Transportation Integrated Search

    1987-03-01

    Breath Alcohol Testing (BAT) programs in Albuquerque and Santa Fe, New Mexico are evaluated in regard to effectiveness, impact, and transferability of the special DWI enforcement squads and their use of BAT Mobiles. Squad activity effectiveness is me...

  15. Effectiveness of urea in enhancing the extractability of 2,4,6-trinitrotoluene from chemically variant soils.

    PubMed

    Das, Padmini; Sarkar, Dibyendu; Makris, Konstantinos C; Punamiya, Pravin; Datta, Rupali

    2013-11-01

    One of the major challenges in developing an effective phytoremediation technology for 2,4,6-trinitrotoluene (TNT) contaminated soils is limited plant uptake resulting from low solubility of TNT. The effectiveness of urea as a solubilizing agent in increasing plant uptake of TNT in hydroponic systems has been documented. Our preliminary greenhouse experiments using urea were also very promising, but further characterization of the performance of urea in highly-complex soil-solution was necessary. The present study investigated the natural retention capacity of four chemically variant soils and optimized the factors influencing the effectiveness of urea in enhancing TNT solubility in the soil solutions. Results show that the extent of TNT sorption and desorption varies with the soil properties, and is mainly dependent on soil organic matter (SOM) content. Hysteretic desorption of TNT in all tested soils suggests irreversible sorption of TNT and indicates the need of using an extractant to increase the release of TNT in soil solutions. Urea significantly (p<0.0001) enhanced TNT extraction from all soils, by increasing its solubility at the solid/liquid interface. Soil organic matter content and urea application rates showed significant effects, whereas pH did not exert any significant effect on urea catalysis of TNT extraction from soil. The optimum urea application rates (125 or 350 mg kg(-1)) for maximizing TNT extraction were within the limits set by the agronomic fertilizer-N rates used for major agricultural crops. The data obtained from this batch study will facilitate the optimization of a chemically-catalyzed phytoremediation model for cleaning up TNT-contaminated soils. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Environmental Technology Verification: Test Report of Mobile Source Selective Catalytic Reduction--Nett Technologies, Inc., BlueMAX 100 version A urea-based selective catalytic reduction technology

    EPA Science Inventory

    Nett Technologies’ BlueMAX 100 version A Urea-Based SCR System utilizes a zeolite catalyst coating on a cordierite honeycomb substrate for heavy-duty diesel nonroad engines for use with commercial ultra-low–sulfur diesel fuel. This environmental technology verification (ETV) repo...

  17. Formaldehyde emission and high-temperature stability of cured urea-formaldehyde resins

    Treesearch

    Shin-ichiro Tohmura; Chung-Yun Hse; Mitsuo Higuchi

    2000-01-01

    A test method for measuring formaldehyde from urea-formaldehyde (UF) resins at high temperature was developed and used to assess the influence of the reaction pH on the formaldehyde emission and heat stability of the cured resins. Additionally, solid-state 13C CP/MAS nuclear magnetic resonance (NMR) techniques were used to investigate the...

  18. Analysis of Consequences of Birth Asphyxia in Infants: A Regional Study in Southern Punjab, Pakistan.

    PubMed

    Samad, Noreen; Farooq, Samia; Hafeez, Kinza; Maryam, Mukharma; Rafi, Muhammad Aftab

    2016-12-01

    To evaluate the biochemical consequences and platelet counts of birth asphyxia in neonates. Cohort study. Department of Child Health, Nishter Medical College and Hospital, Multan, from September to November 2015. The data of 50 (50%) asphyxiated neonates and 50 (50%) non-asphyxiated neonates, with age range less than 1 month, was collected from Children Ward of Nishtar Hospital, Multan, Pakistan. Data on platelet count in blood, kidney function tests (creatinine, urea), liver function tests (bilirubin, alanine aminotransferase (ALT), aspartate aminotransferase (AST)) and cardiac enzyme test (lactate dehydrogenase (LDH)) were analysed by paired sample t-test by SPSS software. Sociodemographic data of those neonate's mothers was also collected. In asphyxiated neonates LDH, ALT, AST, creatinine, bilirubin, urea levels were higher than healthy infants, while the platelet count was smaller in asphyxiated neonates than healthy infants. There was a higher rate of alteration in platelet count, levels of LDH, AST, ALT, urea creatinine and bilirubin in asphyxiated infants. These alterations may be correlated with damage of vital organ of asphyxiated neonates.

  19. Design and synthesis of some new 1-phenyl-3/4-[4-(aryl/heteroaryl/alkyl-piperazine1-yl)-phenyl-ureas as potent anticonvulsant and antidepressant agents.

    PubMed

    Mishra, Chandra Bhushan; Kumari, Shikha; Tiwari, Manisha

    2016-05-01

    A series of 1-phenyl-3/4-[4-(aryl/heteroaryl/alkyl-piperazine1-yl)-phenyl-urea derivatives (29-42) were designed, synthesized and evaluated for their anticonvulsant activity by using maximal electroshock (MES), subcutaneous pentylenetetrazole (scPTZ) seizure tests. The acute neurotoxicity was checked by rotarod assay. Most of the test compounds were found effective in both seizure tests. Compound 30 (1-{4-[4-(4-chloro-phenyl)-piperazin-1-yl]-phenyl}-3-phenyl-urea) exhibited marked anticonvulsant activity in MES as well as scPTZ tests. The phase II anticonvulsant quantification study of compound 30 indicates the ED50 value of 28.5 mg/kg against MES induced seizures. In addition, this compound also showed considerable protection against pilocarpine induced status epilepticus in rats. Seizures induced by 3-mercaptopropionic acid model and thiosemicarbazide were significantly attenuated by compound 30, which suggested its broad spectrum of anticonvulsant activity. Interestingly, compound 30 displayed better antidepressant activity than standard drug fluoxetine. Moreover, compound 30 appeared as a non-toxic chemical entity in sub-acute toxicity studies.

  20. Changes in Serum Electrolytes, Urea, and Creatinine in Aloe Vera-treated Rats

    PubMed Central

    Saka, WA; Akhigbe, RE; Popoola, OT; Oyekunle, OS

    2012-01-01

    This study was carried out to investigate the effect of Aloe vera extract (AvE) on serum electrolytes, urea, and creatinine as indices of renal function in Sprague-Dawley rats. Twelve male Sprague-Dawley rats weighing between 80 and 130 g were used. Rats were divided into two groups: The control and the test groups (n=6). The test group received 1 ml of AvE daily for 28 days. Both the groups fed on standard rat chow and water ad libitum. The results showed a decrease in serum levels of sodium, and potassium, but an increase in the serum levels of bicarbonate, urea, and creatinine in the test group. The changes seen were, however, statistically insignificant, except for the serum levels of sodium and creatinine (P<0.05). It is thus concluded that AvE impairs renal handling of electrolytes with consequent hyponatremia and hypercreatinemia. However, this might be of therapeutic value in conditions associated with hypernatremia. PMID:22754258

  1. Mobile selected ion flow tube mass spectrometry (SIFT-MS) devices and their use for pollution exposure monitoring in breath and ambient air-pilot study.

    PubMed

    Storer, Malina; Salmond, Jennifer; Dirks, Kim N; Kingham, Simon; Epton, Michael

    2014-09-01

    Studies of health effects of air pollution exposure are limited by inability to accurately determine dose and exposure of air pollution in field trials. We explored the feasibility of using a mobile selected ion flow tube mass spectrometry (SIFT-MS) device, housed in a van, to determine ambient air and breath levels of benzene, xylene and toluene following exercise in areas of high motor vehicle traffic. The breath toluene, xylene and benzene concentration of healthy subjects were measured before and after exercising close to a busy road. The concentration of the volatile organic compounds (VOCs), in ambient air were also analysed in real time. Exercise close to traffic pollution is associated with a two-fold increase in breath VOCs (benzene, xylene and toluene) with levels returning to baseline within 20 min. This effect is not seen when exercising away from traffic pollution sources. Situating the testing device 50 m from the road reduced any confounding due to VOCs in the inspired air prior to the breath testing manoeuvre itself. Real-time field testing for air pollution exposure is possible using a mobile SIFT-MS device. This device is suitable for exploring exposure and dose relationships in a number of large scale field test scenarios.

  2. Use of urea and creatinine levels in vaginal fluid for the diagnosis of preterm premature rupture of membranes and delivery interval after membrane rupture.

    PubMed

    Gezer, Cenk; Ekin, Atalay; Golbasi, Ceren; Kocahakimoglu, Ceysu; Bozkurt, Umit; Dogan, Askin; Solmaz, Ulaş; Golbasi, Hakan; Taner, Cuneyt Eftal

    2017-04-01

    To determine whether urea and creatinine measurements in vaginal fluid could be used to diagnose preterm premature rupture of membranes (PPROM) and predict delivery interval after PPROM. A prospective study conducted with 100 pregnant women with PPROM and 100 healthy pregnant women between 24 + 0 and 36 + 6 gestational weeks. All patients underwent sampling for urea and creatinine concentrations in vaginal fluid at the time of admission. Receiver operator curve analysis was used to determine the cutoff values for the presence of PPROM and delivery within 48 h after PPROM. In multivariate logistic regression analysis, vaginal fluid urea and creatinine levels were found to be significant predictors of PPROM (p < 0.001 and p < 0.001, respectively) and delivery within 48 h after PPROM (p = 0.012 and p = 0.017, respectively). The optimal cutoff values for the diagnosis of PPROM were >6.7 mg/dl for urea and >0.12 mg/dl for creatinine. The optimal cutoff values for the detection of delivery within 48 h were >19.4 mg/dl for urea and >0.23 mg/dl for creatinine. Measurement of urea and creatinine levels in vaginal fluid is a rapid and reliable test for diagnosing and also for predicting delivery interval after PPROM.

  3. Urea impairs β cell glycolysis and insulin secretion in chronic kidney disease

    PubMed Central

    Koppe, Laetitia; Nyam, Elsa; Vivot, Kevin; Manning Fox, Jocelyn E.; Dai, Xiao-Qing; Nguyen, Bich N.; Attané, Camille; Moullé, Valentine S.; MacDonald, Patrick E.; Ghislain, Julien

    2016-01-01

    Disorders of glucose homeostasis are common in chronic kidney disease (CKD) and are associated with increased mortality, but the mechanisms of impaired insulin secretion in this disease remain unclear. Here, we tested the hypothesis that defective insulin secretion in CKD is caused by a direct effect of urea on pancreatic β cells. In a murine model in which CKD is induced by 5/6 nephrectomy (CKD mice), we observed defects in glucose-stimulated insulin secretion in vivo and in isolated islets. Similarly, insulin secretion was impaired in normal mouse and human islets that were cultured with disease-relevant concentrations of urea and in islets from normal mice treated orally with urea for 3 weeks. In CKD mouse islets as well as urea-exposed normal islets, we observed an increase in oxidative stress and protein O-GlcNAcylation. Protein O-GlcNAcylation was also observed in pancreatic sections from CKD patients. Impairment of insulin secretion in both CKD mouse and urea-exposed islets was associated with reduced glucose utilization and activity of phosphofructokinase 1 (PFK-1), which could be reversed by inhibiting O-GlcNAcylation. Inhibition of O-GlcNAcylation also restored insulin secretion in both mouse models. These results suggest that insulin secretory defects associated with CKD arise from elevated circulating levels of urea that increase islet protein O-GlcNAcylation and impair glycolysis. PMID:27525435

  4. Refolding of urea-denatured α-chymotrypsin by protein-folding liquid chromatography.

    PubMed

    Congyu, Ke; Wujuan, Sun; Qunzheng, Zhang; Xindu, Geng

    2013-04-01

    An approach for re-folding denatured proteins during proteome research by protein folding liquid chromatography (PFLC) is presented. Standard protein, α-chymotrypsin (α-Chy), was selected as a model protein and hydrophobic interaction chromatography was performed as a typical PFLC; the three different α-Chy states - urea-denatured (U state), its folded intermediates (M state) and nature state (N state) - were studied during protein folding. Based on the test by matrix-assisted laser desorption/ionization time of flight mass spectrometry and bioactivity, only one stable M state of the α-Chy was identified and then it was prepared for further investigation. The specific bioactivity of the refolded α-Chy was found to be higher than that of commercial α-Chy as the urea concentration in the sample solution ranged from 1.0 to 3.0 m; the highest specific bioactivity at urea concentration was 1.0 m, indicating the possibility for re-folding some proteins that have partially or completely lost their bioactivity, as a dilute urea solution was employed for dissolving the sample. The experiment showed that the peak height of its M state increased with increasing urea concentration, and correspondingly decreased in the amount of the refolded α-Chy. When the urea concentration reached 6.0 m, the unfolded α-Chy could not be refolded at all. Copyright © 2012 John Wiley & Sons, Ltd.

  5. Novel fabrication method of the peritoneal dialysis filter using silk fibroin with urease fixation system.

    PubMed

    Moon, Bo Mi; Choi, Myung-Jin; Sultan, Md Tipu; Yang, Jae Won; Ju, Hyung Woo; Lee, Jung Min; Park, Hyun Jung; Park, Ye Ri; Kim, Soo Hyeon; Kim, Dong Wook; Lee, Min Chae; Jeong, Ju Yeon; Lee, Ok Joo; Sung, Gun Yong; Park, Chan Hum

    2017-10-01

    During the last decade, there has been a great advance in the kidney dialysis system by wearable artificial kidney (WAK) system for end-stage renal disease patients. Uremic solute removal and water regeneration system are the most prerequisite for WAK to work properly. In this study, we designed a filtering membrane system by using immobilized urease silk fibroin filter and evaluated its comparative effectiveness with a PVDF filtering system in peritoneal dialysate regeneration system by urea removal efficacy. We evaluated this membrane's characteristic and performances by conducting SEM-EDX analyze, water-binding abilities and porosity test, removal abilities of urea, cytotoxicity assay and enzyme activity assay. Under the condition for optimization of urease, the percentage removal of urea was about 40% and 60% in 50 mg/dL urea solution by urease immobilized PVDF and silk fibroin scaffolds, respectively. The batch experimental result showed that immobilized filter removed more than 50% of urea in 50 mg/dL urea solution. In addition silk fibroin with urease filter removed 90 percent of urea in the peritoneal dialysate after 24 h filtration. We suggest that silk fibroin with urease fixation filter can be used more effectively for peritoneal dialysate regeneration system, which have hydrophilic property and prolonged enzyme activity. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2136-2144, 2017. © 2016 Wiley Periodicals, Inc.

  6. The influence of urea and nitrate nutrients on the bioavailability and toxicity of nickel to Prorocentrum donghaiense (Dinophyta) and Skeletonema costatum (Bacillariophyta).

    PubMed

    Huang, Xu-Guang; Lin, Xie-Chang; Li, Shun-Xing; Xu, Song-Li; Liu, Feng-Jiao

    2016-12-01

    Nitrogen nutrients and nickel(Ni) are ubiquitous in aquatic environments, and they are important for primary production of ocean ecosystem. This study examined the interaction of nitrogen nutrients (specifically urea and nitrate) and Ni on chlorophyll (Chl a) concentration and photosynthesis parameters values of Prorocentrum donghaiense and Skeletonema costatum. The data presented here indicate that low concentration of Ni for P. donghaiense and S. costatum can enhance both Chl a concentration and photosynthesis parameters values when grown in urea containing environment. Despite this increase there was also an observed depression in both species tested when incubated in high concentration of Ni for P. donghaiense and S. costatum regardless of incubating in urea or nitrate. Additionally, EC 50 values of Chl a and Fv/Fm for Ni at different time intervals were calculated in this study. These observations indicated that the Ni tolerance was higher in P. donghaiense as compared to S. costatum. The Ni tolerance of P. donghaiense incubated in urea was higher than that incubating in nitrate. The same phenomenon was not observed in S. costatum, which indicated that the influence of urea was dependent on the species investigated. Thus, urea input could impact Ni bioavailability and toxicity, and then affect the biodynamics thereafter. Copyright © 2016. Published by Elsevier B.V.

  7. Urea Transport and Clinical Potential of Urearetics

    PubMed Central

    Klein, Janet D.; Sands, Jeff M.

    2016-01-01

    Purpose of review Urea is transported by urea transporter proteins in kidney, erythrocytes, and other tissues. Mice in which different urea transporters have been knocked-out have urine concentrating defects, which has led to the development and testing of UT-A and UT-B inhibitors as urearetics. This review summarizes the knowledge gained during the past year on urea transporter regulation and investigations into the clinical potential of urearetics. Recent findings UT-A1 undergoes several post-translational modifications that increase its function by increasing UT-A1 accumulation in the apical plasma membrane. UT-A1 is phosphorylated by PKA, Epac, PKCα, and AMPK, all at different serine residues. UT-A1 is also regulated by 14-3-3, which contributes to UT-A1 removal from the membrane. UT-A1 is glycosylated with various glycan moieties in animal models of diabetes mellitus. Transgenic expression of UT-A1 into UT-A1/UT-A3 knock-out mice restores urine concentrating ability. UT-B is present in descending vasa recta and urinary bladder, and is linked to bladder cancer. Inhibitors of UT-A and UT-B have been developed that result in diuresis with fewer abnormalities in serum electrolytes than conventional diuretics. Summary Urea transporters play critical roles in the urine concentrating mechanism. Urea transport inhibitors are a promising new class of diuretic agents. PMID:27367911

  8. Personal Tracking Charts

    MedlinePlus

    ... Cholesterol (LDL) Urea nitrogen Creatinine Bilirubin Alkaline phosphatase add other tests below that i want to track TEST: TEST: TEST: TEST: these are the major events of my health history Event Date(s) Event Date(s) ...

  9. Occupational asthma due to formaldehyde.

    PubMed Central

    Burge, P S; Harries, M G; Lam, W K; O'Brien, I M; Patchett, P A

    1985-01-01

    Bronchial provocation studies on 15 workers occupationally exposed to formaldehyde are described. The results show that formaldehyde exposure can cause asthmatic reactions, and suggest that these are sometimes due to hypersensitivity and sometimes to a direct irritant effect. Three workers had classical occupational asthma caused by formaldehyde fumes, which was likely to be due to hypersensitivity, with late asthmatic reactions following formaldehyde exposure. Six workers developed immediate asthmatic reactions, which were likely to be due to a direct irritant effect as the reactions were shorter in duration than those seen after soluble allergen exposure and were closely related to histamine reactivity. The breathing zone concentrations of formaldehyde required to elicit these irritant reactions (mean 4.8 mg/m3) were higher than those encountered in buildings recently insulated with urea formaldehyde foam, but within levels sometimes found in industry. Images PMID:4023975

  10. Surgical treatment is effective in severe cases of exercise-induced laryngeal obstruction: A follow-up study.

    PubMed

    Norlander, Katarina; Johansson, Henrik; Jansson, Christer; Nordvall, Lennart; Nordang, Leif

    2015-01-01

    Surgery is an effective treatment in severe cases of supraglottic exercise-induced laryngeal obstruction (E-ILO). Conservatively treated subjects and subjects tested negative for E-ILO, who still experience breathing problems 1-3 years after diagnosis, tend to adjust their physical activity to a greater extent than surgically treated subjects. To investigate how symptoms and level of physical activity change over time in patients with E-ILO who have undergone surgery, patients with E-ILO treated conservatively and patients who tested negative for laryngeal obstruction at continuous laryngoscopy exercise-test (CLE-test). Patients referred for exercise-induced breathing difficulties answered questionnaires at diagnostic CLE-test and at follow-up. Questions regarded exercise-induced breathing problems, current physical activity level, and medical history of asthma and perennial allergy. Out of 84 invited subjects, 59 (70%) answered both questionnaires. Surgically treated subjects had less breathing problems at follow-up compared with conservatively treated subjects and subjects who tested negative (p < 0.001). None of the surgically treated subjects were less physically active or had changed sport due to exercise-induced dyspnoea, whereas 41.7% of the conservatively treated subjects had made such adjustments (p < 0.001).

  11. 10 CFR 712.3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... special nuclear material based on a drug test, a National Agency Check, a psychological assessment, a... expressed in terms of grams of alcohol per 210 liters of breath as indicated by a breath test. Alcohol use... professional expertise in occupational medicine for the HRP. Designated Psychologist means a licensed Ph.D., or...

  12. 10 CFR 712.3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... special nuclear material based on a drug test, a National Agency Check, a psychological assessment, a... expressed in terms of grams of alcohol per 210 liters of breath as indicated by a breath test. Alcohol use... professional expertise in occupational medicine for the HRP. Designated Psychologist means a licensed Ph.D., or...

  13. 13C-breath tests for sucrose digestion in congenital sucrase isomaltase-deficient and sacrosidase-supplemented patients

    USDA-ARS?s Scientific Manuscript database

    Congenital sucrase-isomaltase deficiency (CSID) is characterized by absence or deficiency of the mucosal sucrase-isomaltase enzyme. Specific diagnosis requires upper gastrointestinal biopsy with evidence of low to absent sucrase enzyme activity and normal histology. The hydrogen breath test (BT) is ...

  14. 77 FR 14167 - Approval Tests and Standards for Closed-Circuit Escape Respirators

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-08

    ... Dioxide 3. Oxygen 4. Peak Breathing Pressures 5. Wet-Bulb Temperature L. Section 84.304 Capacity Test... oxygen storage or chemical carbon dioxide scrubber can be altered by impact or any other effect must... inhaled carbon dioxide, average inhaled oxygen, peak breathing pressures, and wet-bulb temperature...

  15. 42 CFR 84.152 - Breathing tube test; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: (i) Be employed on Type C supplied-air respirators of the demand and pressure-demand class; and (ii... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.152 Breathing tube test; minimum requirements. (a)(1) Type A and Type B supplied-air...

  16. Evaluation of portable breath test devices for screening suspected drunken drivers by police in Hennepin County, Minnesota

    DOT National Transportation Integrated Search

    1974-06-01

    This evaluation report examines use in the field of portable breath test (PBT) devices by police in Hennepin County, Minnesota. Thirteen Brog-Warner J2 and J2A-200 "ALERT" devices were deployed by seven enforcement agencies. This report is presented ...

  17. Prevalence of Helicobacter pylori infection and its relation with body mass index in a Chinese population.

    PubMed

    Xu, Chengfu; Yan, Ming; Sun, Yan; Joo, Jungsoo; Wan, Xingyong; Yu, Chaohui; Wang, Qunyan; Shen, Chao; Chen, Peng; Li, Youming; Coleman, William G

    2014-12-01

    Helicobacter pylori infection is highly prevalent worldwide. The association between obesity and H. pylori infection is controversial in the literature. This study aims to investigate the prevalence of H. pylori infection and its relation with body mass index (BMI) in a Chinese population. A cross-sectional study was performed among adults who underwent health checkups at the First Affiliated Hospital, College of Medicine, Zhejiang University in 2013. The prevalence of H. pylori infection was examined by (13)C urea breath tests, and the association between prevalence of H. pylori infection and BMI was analyzed. Of the 8820 participants enrolled, 3859 (43.8%) were positive for H. pylori infection. H. pylori-positive participants had a more unfavorable metabolic profile than H. pylori-negative participants. Overweight/obese participants showed a higher prevalence of H. pylori infection than that of lean participants, and a positive linear correlation between BMI and prevalence of H. pylori infection was observed. Both unadjusted and adjusted analysis revealed that BMI was significantly associated with risk factors of H. pylori infection. Our results showed that BMI was significantly and positively associated with H. pylori infection, and a high BMI was associated with an increased risk of the infection. © 2014 John Wiley & Sons Ltd.

  18. Compliance with the CURB-65 score and the consequences of non-implementation.

    PubMed

    Guo, Q; Li, H-Y; Zhou, Y-P; Li, M; Chen, X-K; Liu, H; Peng, H-L; Yu, H-Q; Chen, X; Liu, N; Liang, L-H; Zhao, Q-Z; Jiang, M

    2011-12-01

    The CURB-65 (confusion, urea >7 mmol/l, respiratory rate ≥ 30 breaths/min, low blood pressure and age ≥ 65 years) score is a simple, well-validated tool for the assessment of severity in community-acquired pneumonia (CAP). It is unknown whether it is used routinely in China. To determine the frequency of use of the CURB-65 score in routine hospital practice and the consequences of non-implementation. A retrospective analysis of medical records from 1230 in-patients with CAP in a Chinese medical college-affiliated hospital. No CAP patient underwent the CURB-65 test at admission. Based on the British Thoracic Society guidelines, the 716 (58.2%) in-patients with a CURB65 score of 0 and the 402 (32.7%) in-patients with CURB-65 score of 1 should have received ambulatory treatment, whereas the 14 (1.2%) patients with CURB65 scores of ≥ 3 should have been admitted to the critical care unit. The maximum excess total annual costs for managing CAP patients with CURB-65 scores of 0 and 1 were estimated at respectively US$94 383.12 and US$66 313.92 in the hospital. The CURB-65 scoring tool in patients with CAP was not applied in routine hospital practice, resulting in inappropriate hospitalisation and excess costs.

  19. Living Conditions and Helicobacter pylori in Adults

    PubMed Central

    Amaral, Odete; Fernandes, Isabel; Pereira, Carlos; Chaves, Claudia; Nelas, Paula; Silva, Daniel

    2017-01-01

    Introduction Infection by the bacterium Helicobacter pylori (H. pylori) is transmissible and is considered a public health issue which affects people of all ages. The objective of this study was to identify factors (lifestyles, dietary factors, and hygiene conditions) related to the prevalence of H. pylori infection. Methods We carried out an observational cross-sectional study with a community sample of adults from the municipalities of Viseu and Sátão, Portugal. The final sample resulted in 166 adults. The data were collected through a self-administered questionnaire with questions regarding sociodemographic aspects and lifestyles. H. pylori infection was identified using the 13C-urea breath test. Results No association was found between the prevalence of H. pylori infection and the use of tobacco, alcohol, or coffee or dietary factors. The prevalence of H. pylori infection was higher in adults who reported higher consumption of fried food and lower consumption of vegetables and fruit. H. pylori infection was significant for the variables of lower frequency of handwashing before going to the bathroom (p = 0.02) and well water consumption (p = 0.05). Conclusion A significant association was found for H. pylori infection with the lower frequency of handwashing before going to the bathroom and the consumption of well water. PMID:29159181

  20. Helicobacter pylori infection and serum leptin, obestatin, and ghrelin levels in Mexican schoolchildren.

    PubMed

    Romo-González, Carolina; Mendoza, Eugenia; Mera, Robertino M; Coria-Jiménez, Rafael; Chico-Aldama, Patricia; Gomez-Diaz, Rita; Duque, Ximena

    2017-10-01

    BackgroundThere is little information about the possible role of Helicobacter pylori infection on appetite-regulating peptides in children. This study evaluated the association between H. pylori infection and serum levels of ghrelin, leptin, and obestatin in schoolchildren.MethodsOne hundred seventy-eight schoolchildren, students at boarding schools in Mexico City, participated. H. pylori infection status was determined every 6 months for 1 year by a breath test using 13 C-urea; schoolchildren with consistently positive or negative results were selected to participate. Age, sex, and body mass index (BMI) were recorded. Serum concentrations of total ghrelin, leptin, and obestatin via specific enzyme-linked immunosorbent assays were determined.ResultsSchoolchildren with H. pylori infection had lower concentration of leptin, -0.54 pg/ml (95% CI: -0.98 to -0.09), compared to the schoolchildren without infection, after adjustment by age, gender, and BMI. And the children with the infection had a median of obestatin lower in 0.99 ng/ml (95% CI: -1.93 to -0.06) compared with the uninfected children after adjustment by BMI.ConclusionAssociation was found between H. pylori infection and decreased serum concentrations of leptin and obestatin. These results suggest that in schoolchildren, H. pylori infection affects the levels of hormones implicated in regulating appetite and energy homeostasis.

  1. Randomised controlled trial of effects of Helicobacter pylori infection and its eradication on heartburn and gastro-oesophageal reflux: Bristol helicobacter project

    PubMed Central

    Harvey, Richard F; Lane, J Athene; Murray, Liam J; Harvey, Ian M; Donovan, Jenny L; Nair, Prakash

    2004-01-01

    Objectives To investigate the effects of Helicobacter pylori infection and its eradication on heartburn and gastro-oesophageal reflux. Design Cross sectional study, followed by a randomised placebo controlled trial. Setting Seven general practices in Bristol, England. Participants 10 537 people, aged 20-59 years, with and without H pylori infection (determined by the 13C-urea breath test). Main outcome measures Prevalence of heartburn and gastro-oesophageal acid reflux at baseline and two years after treatment to eradicate H pylori infection. Results At baseline, H pylori infection was associated with increased prevalence of heartburn (odds ratio 1.14, 95% confidence interval 1.05 to 1.23) but not reflux (1.05, 0.97 to 1.14). In participants with H pylori infection, active treatment had no effect on the overall prevalence of heartburn (0.99, 0.88 to 1.12) or reflux (1.04, 0.91 to 1.19) and did not improve pre-existing symptoms of heartburn or reflux. Conclusions H pylori infection is associated with a slightly increased prevalence of heartburn but not reflux. Treatment to eradicate H pylori has no net benefit in patients with heartburn or gastro-oesophageal reflux. PMID:15126313

  2. Benzene poisoning

    MedlinePlus

    ... treated. The person may receive: Blood and urine tests. Breathing support, including a tube through the mouth into the lungs, and a breathing machine (ventilator). Chest x-ray. Endoscopy -- camera placed down ...

  3. Exhaled breath analysis for lung cancer

    PubMed Central

    Sutedja, Tom G.; Zimmerman, Paul V.

    2013-01-01

    Early diagnosis of lung cancer results in improved survival compared to diagnosis with more advanced disease. Early disease is not reliably indicated by symptoms. Because investigations such as bronchoscopy and needle biopsy have associated risks and substantial costs, they are not suitable for population screening. Hence new easily applicable tests, which can be used to screen individuals at risk, are required. Biomarker testing in exhaled breath samples is a simple, relatively inexpensive, non-invasive approach. Exhaled breath contains volatile and non-volatile organic compounds produced as end-products of metabolic processes and the composition of such compounds varies between healthy subjects and subjects with lung cancer. Many studies have analysed the patterns of these compounds in exhaled breath. In addition studies have also reported that the exhaled breath condensate (EBC) can reveal gene mutations or DNA abnormalities in patients with lung cancer. This review has summarised the scientific evidence demonstrating that lung cancer has distinct chemical profiles in exhaled breath and characteristic genetic changes in EBC. It is not yet possible to accurately identify individuals with lung cancer in at risk populations by any of these techniques. However, analysis of both volatile organic compounds in exhaled breath and of EBC have great potential to become clinically useful diagnostic and screening tools for early stage lung cancer detection. PMID:24163746

  4. A chlorate candle/lithium hydroxide personal breathing apparatus

    NASA Technical Reports Server (NTRS)

    Martin, F. E.

    1972-01-01

    A portable coal mine rescue and survival equipment is reported that consists of a chlorate candle with a lithium hydroxide carbon-dioxide absorbent for oxygen generation, a breathing bag and tubing to conduct breathing to and from the man. A plastic hood incorporating a mouth piece for communication provides also eye protection and prevents inhalation through the nose. Manned testing of a prototype system demonstrated the feasibility of this closed circuit no-maintenance breathing apparatus that provides for good voice communication.

  5. Osmolyte Adjustments as a Pressure Adaptation in Deep-Sea Chondrichthyan Fishes: An Intraspecific Test in Arctic Skates (Amblyraja hyperborea) along a Depth Gradient.

    PubMed

    Yancey, Paul H; Speers-Roesch, Ben; Atchinson, Sheila; Reist, James D; Majewski, Andrew R; Treberg, Jason R

    Accumulation of trimethylamine N-oxide (TMAO) by deep-sea animals is proposed to protect proteins against the destabilizing effects of high hydrostatic pressure (the piezolyte hypothesis). Chondrichthyan fishes (sharks, rays, and chimaeras) provide a unique test of this hypothesis because shallow-living species have elevated TMAO levels to counteract the destabilizing effects of high urea levels accumulated for osmoregulation. Limited interspecific studies of chondrichthyans reveal that increasing depth correlates with decreased urea and increased TMAO levels, suggesting a dynamic balance between destabilizing forces on proteins (high urea, hydrostatic pressure) and TMAO to counteract these forces. Indeed, an inability to minimize urea levels or maximize TMAO levels has been proposed to explain why chondrichthyans are absent in the vast abyssal region. An unresolved question is whether the depth-related changes in chondrichthyan osmolytes are a flexible response to depth or whether phylogenetic differences in species-specific physiological set points for osmolytes account for the differences seen with depth. Sampling Arctic skates (Amblyraja hyperborea) across a 1,015-m depth gradient in the Beaufort Sea, we measured organic osmolytes in muscle using spectrophotometry and high-performance liquid chromatography. We found that the urea-to-TMAO ratio decreased linearly with depth, with tighter correlation than that seen in interspecific studies. Minor osmolytes, including betaine, sarcosine, and some α-amino acids, also declined with depth, apparently replaced (as with urea) by TMAO (a stronger piezolyte than those solutes). These data provide the first intraspecific evidence that flexible adjustments of osmolyte combinations are a key response for deep-sea living in individual chondrichthyans, supporting the piezolyte hypothesis.

  6. Breath tests and irritable bowel syndrome

    PubMed Central

    Rana, Satya Vati; Malik, Aastha

    2014-01-01

    Breath tests are non-invasive tests and can detect H2 and CH4 gases which are produced by bacterial fermentation of unabsorbed intestinal carbohydrate and are excreted in the breath. These tests are used in the diagnosis of carbohydrate malabsorption, small intestinal bacterial overgrowth, and for measuring the orocecal transit time. Malabsorption of carbohydrates is a key trigger of irritable bowel syndrome (IBS)-type symptoms such as diarrhea and/or constipation, bloating, excess flatulence, headaches and lack of energy. Abdominal bloating is a common nonspecific symptom which can negatively impact quality of life. It may reflect dietary imbalance, such as excess fiber intake, or may be a manifestation of IBS. However, bloating may also represent small intestinal bacterial overgrowth. Patients with persistent symptoms of abdominal bloating and distension despite dietary interventions should be referred for H2 breath testing to determine the presence or absence of bacterial overgrowth. If bacterial overgrowth is identified, patients are typically treated with antibiotics. Evaluation of IBS generally includes testing of other disorders that cause similar symptoms. Carbohydrate malabsorption (lactose, fructose, sorbitol) can cause abdominal fullness, bloating, nausea, abdominal pain, flatulence, and diarrhea, which are similar to the symptoms of IBS. However, it is unclear if these digestive disorders contribute to or cause the symptoms of IBS. Research studies show that a proper diagnosis and effective dietary intervention significantly reduces the severity and frequency of gastrointestinal symptoms in IBS. Thus, diagnosis of malabsorption of these carbohydrates in IBS using a breath test is very important to guide the clinician in the proper treatment of IBS patients. PMID:24976698

  7. Treatment of Chronic Breath-Holding in an Adult with Severe Mental Retardation: A Clinical Case Study

    ERIC Educational Resources Information Center

    Reed, Derek D.; Martens, Brian K.

    2008-01-01

    We describe a clinical case study surrounding the behavioral assessment and operant treatment of, an adult with severe mental retardation who engaged in chronic breath-holding. In this clinical case, previous neurological and medical testing had ruled out biological bases for the individual's breath-holding. A functional behavioral assessment…

  8. How to deal with morning bad breath: A randomized, crossover clinical trial

    PubMed Central

    Oliveira-Neto, Jeronimo M.; Sato, Sandra; Pedrazzi, Vinícius

    2013-01-01

    Context: The absence of a protocol for the treatment of halitosis has led us to compare mouthrinses with mechanical oral hygiene procedures for treating morning breath by employing a hand-held sulfide monitor. Aims: To compare the efficacy of five modalities of treatment for controlling morning halitosis in subjects with no dental or periodontal disease. Settings and Design: This is a five-period, randomized, crossover clinical trial. Materials and Methods: Twenty volunteers were randomly assigned to the trial. Testing involved the use of a conventional tongue scraper, a tongue scraper joined to the back of a toothbrush's head, two mouthrinses (0.05% cetylpyridinium chloride and 0.12% chlorhexidine digluconate) and a soft-bristled toothbrush and fluoride toothpaste for practicing oral hygiene. Statistical Analysis Used: Data analysis was performed using SPSS version 17 for Windows and NCSS 2007 software (P < 0.05). The products and the periods were compared with each other using the Friedman's test. When significant differences (P < 0.05) were determined, the products and periods were compared in pairs by using the Wilcoxon's test and by adjusting the original significance level (0.05) for multiple comparisons by using the Bonferroni's method. Results: The toothbrush's tongue scraper was able to significantly reduce bad breath for up to 2 h. Chlorhexidine reduced bad breath only at the end of the second hour, an effect that lasted for 3 h. Conclusions: Mechanical tongue cleaning was able to immediately reduce bad breath for a short period, whereas chlorhexidine and mechanical oral hygiene reduced bad breath for longer periods, achieving the best results against morning breath. PMID:24554886

  9. Electromyographic fatigue of orbicular oris muscles during exercises in mouth and nasal breathing children.

    PubMed

    Busanello-Stella, Angela Ruviaro; Blanco-Dutra, Ana Paula; Corrêa, Eliane Castilhos Rodrigues; Silva, Ana Maria Toniolo da

    2015-01-01

    To investigate the process of fatigue in orbicularis oris muscles by analyzing the median frequency of electromyographic signal and the referred fatigue time, according to the breathing mode and the facial pattern. The participants were 70 children, aged 6 to 12 years, who matched the established criteria. To be classified as 36 nasal-breathing and 34 mouth-breathing children, they underwent speech-language, otorhinolaryngologic, and cephalometric evaluation. For the electromyographic assessment, the children had to sustain lip dumbbells weighing 40, 60, and 100 g and a lip exerciser, until the feeling of fatigue. Median frequency was analyzed in 5, 10, 15, and 20 seconds of activity. The referred time of the feeling of fatigue was also recorded. Data were analyzed through the analysis of variance--repeated measures (post hoc Tukey's test), Kruskal-Wallis test, and Mann-Whitney U-test. A significant decrease in the median frequency from 5 seconds of activity was observed, independently from the comparison between the groups. On comparison, the muscles did not show significant decrease. The reported time for the feeling of fatigue was shorter for mouth-breathing individuals. This feeling occurred after the significant decrease in the median frequency. There were signals that indicated myoelectric fatigue for the orbicularis oris muscles, in both groups analyzed, from the first 5 seconds of activity. Myoelectric fatigue in the orbicularis oris muscles preceded the reported feeling of fatigue in all groups. The account for fatigue time was influenced by only the breathing pattern, occurring more precociously in mouth-breathing children.

  10. Asphalt cement poisoning

    MedlinePlus

    ... treated. The person may receive: Blood and urine tests. Breathing support, including a tube through the mouth into the lungs, and a breathing machine (ventilator). Bronchoscopy -- camera placed down the throat to ...

  11. First-line Bismuth-containing Five-day Concomitant Quintuple Therapy for Helicobacter Pylori Eradication.

    PubMed

    Dolapcioglu, Can; Sayiner, Mehmet; Akkus, Esra Elif; Kural, Abdulaziz; Dolapcioglu, Hatice; Dabak, Resat; Ahishali, Emel

    2016-04-01

    Widespread use of antibiotics has resulted in increased rates of antibiotic resistance and decreased rates of Helicobacter pylori (H. pylori) eradication, leading to a search for newer therapeutic options. This study aimed to examine the efficacy, tolerability, and patient compliance of a first-line bismuth-containing 5-day concomitant quintuple therapy. This prospective study included 144 eradication treatment naïve H. pylori positive patients with dyspeptic complaints. Patients received the following concomitant quintuple therapy for 5 days: bismuth subcitrate 300 mg q.i.d, omeprazole 20 mg b.i.d, clarithromycin 500 mg b.i.d., amoxicillin 1 g b.i.d., and metronidazole 500 mg t.i.d. Eradication was assessed with H. pylori stool antigen test or urea-breath test 6 weeks after the completion of therapy. Treatment compliance rate in this study was 97.2%. Intention to treat and per-protocol eradication rates were 134/144 (93.1%, 95% CI, 88.9-97.2) and 134/140 (95.7%, 95% CI, 92.2-98.6), respectively. Side effect was reported by 8.5% of the patients that attended follow-up visits, including epigastric pain (2.8%), nausea/vomiting (2.1%), diarrhea (1.4%), taste disturbance (1.4%), and fatigue (0.7%). Bismuth-containing, short course, quintuple concomitant therapy appears to be an effective and safe therapeutic option for the first-line H. pylori eradication, particularly in populations with high resistance. © 2015 John Wiley & Sons Ltd.

  12. Second-line bismuth-containing quadruple therapy for Helicobacter pylori eradication and impact of diabetes

    PubMed Central

    Kim, Sung Eun; Park, Moo In; Park, Seun Ja; Moon, Won; Kim, Jae Hyun; Jung, Kyoungwon; Kim, Hae Koo; Lee, Young Dal

    2017-01-01

    AIM To investigate Helicobacter pylori (H. pylori) eradication rates using second-line bismuth-containing quadruple therapy and to identify predictors of eradication failure. METHODS This study included 636 patients who failed first-line triple therapy and received 7 d of bismuth-containing quadruple therapy between January 2005 and December 2015. We retrospectively demonstrated H. pylori eradication rates with respect to the year of therapy as well as demographic and clinical factors. H. pylori eradication was confirmed by a 13C-urea breath test or a rapid urease test at least 4 wk after the completion of bismuth-based quadruple therapy: proton pump inhibitor, metronidazole, bismuth, and tetracycline. RESULTS The overall eradication rates by intention-to-treat analysis and per-protocol analysis were 73.9% (95%CI: 70.1%-77.4%) and 94.5% (95%CI: 92.4%-96.5%), respectively. Annual eradication rates from 2005 to 2015 were 100.0%, 92.9%, 100.0%, 100.0%, 100.0%, 97.4%, 100.0%, 93.8%, 84.4%, 98.9%, and 92.5%, respectively, by per-protocol analysis. A multivariate analysis showed that diabetes mellitus (OR = 3.99, 95%CI: 1.56-10.20, P = 0.004) was associated with H. pylori eradication therapy failure. CONCLUSION The second-line bismuth-containing quadruple therapy for H. pylori infection is still effective in Korea, and diabetes mellitus is suggested to be a risk factor for eradication failure. PMID:28246480

  13. Dietary and anthropometric indicators of nutritional status in relation to Helicobacter pylori infection in a paediatric population.

    PubMed

    Janjetic, Mariana A; Mantero, Paula; Cueto Rua, Eduardo; Balcarce, Norma; Zerbetto de Palma, Gerardo; Catalano, Mariana; Zubillaga, Marcela B; Boccio, José R; Goldman, Cinthia G

    2015-04-14

    It has been postulated that Helicobacter pylori infection could affect growth and appetite, consequently influencing body weight. Therefore, the association between H. pylori infection and the dietary and anthropometric indicators of nutritional status of a paediatric population were investigated. A total of 525 children (aged 4-16 years) who were referred to the gastroenterology unit of the Sor Maria Ludovica Children's Hospital from Buenos Aires, Argentina, were enrolled and completed an epidemiological questionnaire. H. pylori infection was diagnosed using the ¹³C-urea breath test (¹³C-UBT). Height and weight were assessed for calculation of anthropometric indicators. Energy and macronutrient intakes were estimated by 24 h dietary recall. Data analysis was performed using a χ² test, a Student's t test, a Mann-Whitney U test and linear and logistic regressions. The prevalence of H. pylori infection was 25·1 % (with a mean age of 10·1 (SD 3·1) years). A tendency towards lower energy, carbohydrate, protein and fat intakes was observed in infected patients; however, it was not associated with H. pylori infection in any of the evaluated age groups (4-8, 9-13 and 14-16 years). Underweight, stunting, overweight and obesity were also not associated with the infection. Although height-for-age and BMI-for-age Z scores tended to be lower in infected patients, the differences between H. pylori-positive and H. pylori-negative children were not statistically significant. In conclusion, H. pylori infection was not associated with dietary intake or with anthropometric indicators in the present population of children with gastrointestinal symptoms; however, an increased sample size would be needed to confirm the observed tendency towards lower dietary intake and lower anthropometric indicators of nutritional status in H. pylori-infected children.

  14. Diagnostic value of morphological, physiological and biochemical tests in distinguishing Trichophyton rubrum from Trichophyton mentagrophytes complex.

    PubMed

    Ates, Aylin; Ozcan, Kadri; Ilkit, Macit

    2008-12-01

    The two most frequently encountered dermatophyte etiologic agents of glabrous skin and nail dermatophytoses are Trichophyton rubrum and T. mentagrophytes. This study was aimed to discuss the efficacy of morphological, physiological and biochemical diagnostic tests commonly used in the identification of T. rubrum and members of the T. mentagrophytes complex. In this study, we evaluated; hydrolysis of urea in broth and on urea agar slants and Petri plates incubated at 22 degrees C, 28 degrees C and 37 degrees C, in vitro hair perforation (blond child, sheep and goat hair), pigment production on cornmeal dextrose agar (CMDA) and bromcresol purple-milk solids-glucose agar (BCP-MS-G), Tween opacity, sorbitol assimilation, and salt tolerance. Additionally, the production of micro- and macroconidia was investigated by using brain heart infusion agar (BHIA), Christensen's urea agar in Petri plates (UPA), CMDA, Lowenstein-Jensen agar (LJA), malt extract agar, oatmeal agar, Oxoid chromogenic Candida agar, and potato dextrose agar. All cultures were incubated at 28 degrees C, and conidial production was compared on days 5, 10 and 15. It was found that the urea hydrolysis test yielded more rapid and significant results when urea medium was prepared in Petri plates and incubated at 28 degrees C (P<0.01). LJA supported the highest production of microconidia after 15 days (P<0.001). Additionally, it was found that T. rubrum strains produced red pigment on CMDA (P<0.01) and BCP-MS-G, while strains of the T. mentagrophytes species complex did not. A special algorithm containing the various test procedures employed in these studies is presented which was found to be useful in the differentiation of T. rubrum strains from T. mentagrophytes complex. Our results revealed that UPA, CMDA, BCP-MS-G, LJA, and BHIA may be used as common mycological agars in routine practice.

  15. Heat stability of cured urea-formaldehyde resins by measuring formaldehyde emission

    Treesearch

    Shin-ichiro Tohmura; Chung-Yun Hse; Mitsuo Higuchi

    1999-01-01

    A test method for measuring formaldehyde from urea-formaldehyde (UF) resins at high tempera­tures was developed and used to assess the influence of the reaction pH at synthesis on the formaldehyde emission during cure and heat stability of the cured resins without water. Additionally, 13C-CP/MAS solid-state nuclear magnetic resonance (NMR)...

  16. Monitoring of rapid blood pH variations by CO detection in breath with tunable diode laser

    NASA Astrophysics Data System (ADS)

    Kouznetsov, Andrian I.; Stepanov, Eugene V.; Zyrianov, Pavel V.; Shulagin, Yurii A.; Diachenko, Alexander I.; Gurfinkel, Youri I.

    1997-06-01

    Detection of endogenous carbon monoxide content in breath with tunable diode lasers (TDL) was proposed for noninvasive monitoring of rapid blood pH variation. Applied approach is based on high sensitivity of the haemoglobin and myoglobin affinity for CO to blood pH value and an ability to detect rapidly small variations of CO content in expired air. Breath CO absorption in 4.7 micrometers spectral region was carefully measured using PbSSe tunable diode laser that can provide 1 ppb CO concentration sensitivity and 10 s time constant. Applied TDL gas analyzer was used to monitor expired air of studied persons in physiological tests including hyperventilation and physical load. Simultaneous blood tests were conducted to demonstrate correlation between blood and breath chemical parameters.

  17. Guidelines proposal for clinical recognition of mouth breathing children.

    PubMed

    Pacheco, Maria Christina Thomé; Casagrande, Camila Ferreira; Teixeira, Lícia Pacheco; Finck, Nathalia Silveira; de Araújo, Maria Teresa Martins

    2015-01-01

    Mouth breathing (MB) is an etiological factor for sleep-disordered breathing (SDB) during childhood. The habit of breathing through the mouth may be perpetuated even after airway clearance. Both habit and obstruction may cause facial muscle imbalance and craniofacial changes. The aim of this paper is to propose and test guidelines for clinical recognition of MB and some predisposing factors for SDB in children. Semi-structured interviews were conducted with 110 orthodontists regarding their procedures for clinical evaluation of MB and their knowledge about SDB during childhood. Thereafter, based on their answers, guidelines were developed and tested in 687 children aged between 6 and 12 years old and attending elementary schools. There was no standardization for clinical recognition of MB among orthodontists. The most common procedures performed were inefficient to recognize differences between MB by habit or obstruction. The guidelines proposed herein facilitate clinical recognition of MB, help clinicians to differentiate between habit and obstruction, suggest the most appropriate treatment for each case, and avoid maintenance of mouth breathing patterns during adulthood.

  18. Prediction of ammonia emission from dairy cattle manure based on milk urea nitrogen: relation of milk urea nitrogen to urine urea nitrogen excretion.

    PubMed

    Burgos, S A; Fadel, J G; Depeters, E J

    2007-12-01

    The objectives of this study were to assess the relationship between urinary urea N (UUN) excretion (g/d) and milk urea N (MUN; mg/dL) and to test whether the relationship was affected by stage of lactation and the dietary crude protein (CP) content. Twelve lactating multiparous Holstein cows were randomly selected and blocked into 3 groups of 4 cows intended to represent early [123 +/- 26 d in milk (DIM); mean +/- standard deviation], mid (175 +/- 3 DIM), and late (221 +/- 12 DIM) lactation stages. Cows within each stage of lactation were randomly assigned to a treatment sequence within a split-plot Latin square balanced for carryover effects. Stage of lactation formed the main plots (squares) and dietary CP levels (15, 17, 19, and 21% of diet dry matter) formed the subplots. Graded amounts of urea were added to the basal total mixed ration to linearly increase dietary CP content while maintaining similar concentrations of all other nutrients among treatments. The experimental periods lasted 7 d, with d 1 to 6 used for adjustment to diets and d 7 used for total collection of urine as well as milk and blood sample collection. Dry matter intake and yields of milk, fat, protein, and lactose declined progressively with lactation stage and were unaffected by dietary CP content. Milk and plasma urea-N as well as UUN concentration and excretion increased in response to dietary CP content. Milk and urine urea-N concentration rose at increasing and decreasing rates, respectively, as a function of plasma urea-N. The renal urea-N clearance rate differed among lactation stages and dietary CP contents. The relationship between UUN excretion and MUN differed among lactation stages and diverged from linearity for cows in early and late lactation. However, these differences were restricted to very high MUN concentrations. Milk urea N may be a useful tool to predict the UUN excretion and ultimately NH(3) emission from dairy cattle manure.

  19. eAMI: A Qualitative Quantification of Periodic Breathing Based on Amplitude of Oscillations

    PubMed Central

    Fernandez Tellez, Helio; Pattyn, Nathalie; Mairesse, Olivier; Dolenc-Groselj, Leja; Eiken, Ola; Mekjavic, Igor B.; Migeotte, P. F.; Macdonald-Nethercott, Eoin; Meeusen, Romain; Neyt, Xavier

    2015-01-01

    Study Objectives: Periodic breathing is sleep disordered breathing characterized by instability in the respiratory pattern that exhibits an oscillatory behavior. Periodic breathing is associated with increased mortality, and it is observed in a variety of situations, such as acute hypoxia, chronic heart failure, and damage to respiratory centers. The standard quantification for the diagnosis of sleep related breathing disorders is the apnea-hypopnea index (AHI), which measures the proportion of apneic/hypopneic events during polysomnography. Determining the AHI is labor-intensive and requires the simultaneous recording of airflow and oxygen saturation. In this paper, we propose an automated, simple, and novel methodology for the detection and qualification of periodic breathing: the estimated amplitude modulation index (eAMI). Patients or Participants: Antarctic cohort (3,800 meters): 13 normal individuals. Clinical cohort: 39 different patients suffering from diverse sleep-related pathologies. Measurements and Results: When tested in a population with high levels of periodic breathing (Antarctic cohort), eAMI was closely correlated with AHI (r = 0.95, P < 0.001). When tested in the clinical setting, the proposed method was able to detect portions of the signal in which subclinical periodic breathing was validated by an expert (n = 93; accuracy = 0.85). Average eAMI was also correlated with the loop gain for the combined clinical and Antarctica cohorts (r = 0.58, P < 0.001). Conclusions: In terms of quantification and temporal resolution, the eAMI is able to estimate the strength of periodic breathing and the underlying loop gain at any given time within a record. The impaired prognosis associated with periodic breathing makes its automated detection and early diagnosis of clinical relevance. Citation: Fernandez Tellez H, Pattyn N, Mairesse O, Dolenc-Groselj L, Eiken O, Mekjavic IB, Migeotte PF, Macdonald-Nethercott E, Meeusen R, Neyt X. eAMI: a qualitative quantification of periodic breathing based on amplitude of oscillations. SLEEP 2015;38(3):381–389. PMID:25581914

  20. Detection of nitric oxide in exhaled human breath: exercise and resting determinations.

    PubMed

    Mantione, Kirk J; Esch, Tobias; Stefano, George B

    2007-03-01

    Nitric oxide has become a vital indicator of health since many cells produce it constitutively. It is present in exhaled breath and can be measured. A Kiernan NO Breath analyzer (KNB) was used in the present study to determine nitric oxide (NO) levels in exhaled human breath. The KNB was calibrated via measuring NO gas in O2-free N2 obtained from Scott Specialty Gases. Human subjects aged 21 to 45 were instructed to place the KNB over their nose and mouth and to breathe normally before and after mild exercise (n=24) and relaxation (n=20). Mean exhaled NO measurements were compared before and after the protocols using paired t-tests. Regardless of the test, all subjects exhibited NO in their exhaled breath. Exhaled NO decreased significantly after exercise compared to the first reading just prior to the exercise protocol. The mean +/-SE of exhaled NO was 22.8+/-4 before and 13.0+/-2 ppb after exercise (n=24, P=0.003). In the resting experiment, exhaled NO was demonstrated to increase significantly after 10 min compared to the reading taken right after the individuals sat down. The present study demonstrates NO in exhaled human breath can vary, reflecting the activity state of the individual. Additionally, the study demonstrates that NO in exhaled human breath can be measured rapidly, with high sensitivity, and in real time via the KNB, representing an affordable means to achieve this determination.

  1. Frequency of rhinitis and orofacial disorders in patients with dental malocclusion

    PubMed Central

    Imbaud, Tamara Christine de Souza; Mallozi, Márcia Carvalho; Domingos, Vanda Beatriz Teixeira Coelho; Solé, Dirceu

    2016-01-01

    Abstract Objective: To describe the frequency and etiology of rhinitis, oral breathing, types of malocclusion and orofacial disorders in patients treated for dental malocclusion. Methods: Patients with poor dental occlusion (n=89, 8-15 years) undergoing orthodontic treatment at the Postgraduate Orthodontics Center (São Paulo, Brazil) participated in the study. Rhinitis and oral breathing were diagnosed by anamnesis, clinical assessment and allergic etiology of rhinitis through immediate hypersensitivity skin prick test with airborne allergens. The association between types of breathing (oral or nasal), rhinitis and types of dental malocclusion, bruxism and cephalometric alterations (increased Y axis of facial growth) compared to standard cephalometric tracing (Escola de Odontologia da Universidade de São Paulo) were assessed. Results: The frequency of rhinitis in patients with dental malocclusion was 76.4% (68), and, of these, 81.7% were allergic (49/60 positive skin prick test), whereas the frequency of oral breathing was 62.9%. There was a significant association between an increased Y axis of facial growth and oral breathing (p<0.001), as well as between oral breathing and rhinitis (p=0.009). There was no association between rhinitis and bruxism. Conclusions: The frequency of rhinitis in children with dental malocclusion is higher than that in the general population, which is approximately 30%. Patients with oral breathing have a tendency to a dolichofacial growth pattern (increased Y axis of facial growth). In patients with rhinitis, regardless of the presence of oral breathing, the dolichofacial growth tendency was not observed. PMID:26631324

  2. Afternoon serum-melatonin in sleep disordered breathing.

    PubMed

    Ulfberg, J; Micic, S; Strøm, J

    1998-08-01

    To study afternoon serum-melatonin values in patients with sleep disordered breathing. Melatonin has a strong circadian rhythm with high values during the night-time and low values in the afternoon. Sleep disordered breathing may change the circadian rhythm of melatonin which may have diagnostic implications. The Sleep Laboratory, The Department of Internal Medicine, Avesta Hospital, Sweden, and the Department of Anaesthesiology, Glostrup University Hospital, Copenhagen, Denmark. We examined 60 consecutive patients admitted for sleep disordered breathing and 10 healthy non snoring controls. The patients underwent a sleep apnoea screening test having a specificity of 100% for the obstructive sleep apnoea syndrome (OSAS) using a combination of static charge sensitive bed and oximetry. Obstructive sleep apnoea syndrome was found in 49 patients, eight patients had borderline sleep disordered breathing (BSDB) and three patients were excluded due to interfering disease. Patients and controls had an afternoon determination of serum-melatonin. The Epworth Sleepiness Scale was used to score day-time sleepiness. In comparison with normal controls patients suffering from OSAS had significantly higher serum-melatonin levels in the afternoon. However, as a diagnostic test for OSAS in patients with sleep disordered breathing serum-melatonin showed a low sensitivity but a high specificity. The results indicate that breathing disorders during sleep in general affect pineal function. Sleep disordered breathing seems to disturb pineal function. Determination of afternoon serum-melatonin alone or together with a scoring of daytime sleepiness does not identify OSAS-patients in a heterogeneous population of patients complaining of heavy snoring and excessive daytime sleepiness.

  3. Noise Reduction in Breath Sound Files Using Wavelet Transform Based Filter

    NASA Astrophysics Data System (ADS)

    Syahputra, M. F.; Situmeang, S. I. G.; Rahmat, R. F.; Budiarto, R.

    2017-04-01

    The development of science and technology in the field of healthcare increasingly provides convenience in diagnosing respiratory system problem. Recording the breath sounds is one example of these developments. Breath sounds are recorded using a digital stethoscope, and then stored in a file with sound format. This breath sounds will be analyzed by health practitioners to diagnose the symptoms of disease or illness. However, the breath sounds is not free from interference signals. Therefore, noise filter or signal interference reduction system is required so that breath sounds component which contains information signal can be clarified. In this study, we designed a filter called a wavelet transform based filter. The filter that is designed in this study is using Daubechies wavelet with four wavelet transform coefficients. Based on the testing of the ten types of breath sounds data, the data is obtained in the largest SNRdB bronchial for 74.3685 decibels.

  4. [Reliability study on the infrared spectrometry for measuring the delta over baseline for breath 13C].

    PubMed

    Wang, Min; Wang, Zhiling; Gou, Lingyan; Zhang, Yuhui; Yang, Xiaoguang; Sha, Lei; Li, Min

    2013-03-01

    To assess the validity and reliability of the infrared spectrometry for measuring the delta over baseline for breath 13C. Twenty-four healthy adults were selected, including twelve males and twelve females. 13C-Leucine was used as tracer in stable isotope metabolic experiments. One baseline breath was collected before the tracer protocol began. Other breath samples were collected at 60, 120, 180, 195, 210, 225, 240, 255, 270 and 300 min post-tracer challenge. The delta over baseline for breath 13C was measured by the infrared spectrometry and Heliview 13C breath analyzer. No significant differences were found between the infrared spectrometry and Heliview 13C breath analyzer in measuring the delta over baseline for breath 13C. The F value and p value of two-way ANOVA were 0.29 and 0.5874 respectively. The t and p value of consistency test were 0.48 and 0.6346 respectively. The 13C infrared spectrometry can reliably measure the delta over baseline for breath 13C.

  5. Breathing and sense of self: visuo-respiratory conflicts alter body self-consciousness.

    PubMed

    Adler, Dan; Herbelin, Bruno; Similowski, Thomas; Blanke, Olaf

    2014-11-01

    Bodily self-consciousness depends on the processing of interoceptive and exteroceptive signals. It can be disrupted by inducing signal conflicts. Breathing, at the crossroad between interoception and exteroception, should contribute to bodily self-consciousness. We induced visuo-respiratory conflicts in 17 subjects presented with a virtual body or a parallelepidedal object flashing synchronously or asynchronously with their breathing. A questionnaire detected illusory changes in bodily self-consciousness and breathing agency (the feeling of sensing one's breathing command). Changes in self-location were tested by measuring reaction time during mental ball drop (MBD). Synchronous illumination changed the perceived location of breathing (body: p=0.008 vs. asynchronous; object: p=0.013). It resulted in a significant change in breathing agency, but no changes in self-identification. This was corroborated by prolonged MBD reaction time (body: +0.045s, 95%CI [0.013; 0.08], p=0.007). We conclude that breathing modulates bodily self-consciousness. We also conclude that one can induce the irruption of unattended breathing into consciousness without modifying respiratory mechanics or gas exchange. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. 32 CFR 634.37 - Voluntary breath and bodily fluid testing based on implied consent.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.37 Voluntary breath and bodily fluid testing based on implied consent... the person was driving under the influence of alcohol or drugs. (3) A request was made to the person...

  7. 32 CFR 634.37 - Voluntary breath and bodily fluid testing based on implied consent.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.37 Voluntary breath and bodily fluid testing based on implied consent... the person was driving under the influence of alcohol or drugs. (3) A request was made to the person...

  8. Estimating the concentration of urea and creatinine in the human serum of normal and dialysis patients through Raman spectroscopy.

    PubMed

    de Almeida, Maurício Liberal; Saatkamp, Cassiano Junior; Fernandes, Adriana Barrinha; Pinheiro, Antonio Luiz Barbosa; Silveira, Landulfo

    2016-09-01

    Urea and creatinine are commonly used as biomarkers of renal function. Abnormal concentrations of these biomarkers are indicative of pathological processes such as renal failure. This study aimed to develop a model based on Raman spectroscopy to estimate the concentration values of urea and creatinine in human serum. Blood sera from 55 clinically normal subjects and 47 patients with chronic kidney disease undergoing dialysis were collected, and concentrations of urea and creatinine were determined by spectrophotometric methods. A Raman spectrum was obtained with a high-resolution dispersive Raman spectrometer (830 nm). A spectral model was developed based on partial least squares (PLS), where the concentrations of urea and creatinine were correlated with the Raman features. Principal components analysis (PCA) was used to discriminate dialysis patients from normal subjects. The PLS model showed r = 0.97 and r = 0.93 for urea and creatinine, respectively. The root mean square errors of cross-validation (RMSECV) for the model were 17.6 and 1.94 mg/dL, respectively. PCA showed high discrimination between dialysis and normality (95 % accuracy). The Raman technique was able to determine the concentrations with low error and to discriminate dialysis from normal subjects, consistent with a rapid and low-cost test.

  9. Optoacoustic Determination of Carbon Dioxide Concentration in Exhaled Breath in Various Human Diseases*

    NASA Astrophysics Data System (ADS)

    Ageev, V. G.; Nikiforova, O. Yu.

    2016-11-01

    We determined the carbon dioxide concentrations in exhaled breath from healthy donors and patients with various diseases from the absorption spectra of test samples, recorded on a laser optoacoustic gas analyzer based on a CO2 laser. We observed that the carbon dioxide concentrations in exhaled breath from healthy donors is higher than in patients with various diseases.

  10. Test plan 241-C-103 natural breathing characteristics evaluation using the ultra sensitive flowmeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertelendy, N.A.

    1995-02-13

    To facilitate the reduction of worker exposure to hazardous fumes and vapors, it is imperative to characterize and measure flows out of waste tanks that breathe due to atmospheric pressure changes. These measurements will lead to a better understanding of how these tanks breathe and thus will aid in better worker exposure control at lower cost.

  11. A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals

    PubMed Central

    Ma, Yong-Jian; Zhang, Hou-De; Ji, Yong-Qiang; Zhu, Guo-Liang; Huang, Jia-Liang; Du, Li-Tao; Cao, Ping; Zang, De-Yue; Du, Ji-Hui; Li, Rong; Wang, Lei

    2016-01-01

    This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0 ± 5.9 d) rabbits, rabbits given 10 mg/kg·d−1 of ribavirin (RIB10, 31.0 ± 4.0 d), and rabbits given 20 mg/kg·d−1 of ribavirin (RIB20, 25.0 ± 2.9 d) were statistically similar (all p > 0.05) to and linearly correlated (r = 0.96, p < 0.01) with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0 ± 2.7 d; RIB10, 33.0 ± 1.3 d; and RIB20, 27.0 ± 0.8 d). The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models. PMID:27294128

  12. Effects of exogenous lactase administration on hydrogen breath excretion and intestinal symptoms in patients presenting lactose malabsorption and intolerance.

    PubMed

    Ibba, Ivan; Gilli, Agnese; Boi, Maria Francesca; Usai, Paolo

    2014-01-01

    To establish whether supplementation with a standard oral dose of Beta-Galactosidase affects hydrogen breath excretion in patients presenting with lactose malabsorption. Ninety-six consecutive patients positive to H2 Lactose Breath Test were enrolled. Mean peak H2 levels, the time to reach the peak H2, the time to reach the cut-off value of 20 ppm, the cumulative breath H2 excretion, the areas under the curve, and a Visual Analogical 10-point Scale for symptoms were calculated. Genotyping of the C/T-13910 variant was carried out. Following the oral administration of Beta-Galactosidase, in 21.88% of the cases, H2 Lactose Breath Test became negative (Group A), while mean peak H2 levels (74.95 ppm versus 7.85), P < 0.0000, in 17.71% (Group B) were still positive, with the H2 level 20 ppm above the baseline, but the peak H2 levels were significantly lower than those observed at the baseline test (186.7 ppm versus 66.64), P < 0.0000, while in 60.41% (Group C) they were still positive with the peak H2 levels similar to those observed at the baseline test (94.43 versus 81.60 ppm). All 96 individuals tested presented the C/C-13910 genotype nonpersistence. The response to oral administration of Beta-Galactosidase in patients with symptoms of lactose malabsorption presents a significant variability.

  13. Update on diagnostic value of breath test in gastrointestinal and liver diseases

    PubMed Central

    Siddiqui, Imran; Ahmed, Sibtain; Abid, Shahab

    2016-01-01

    In the field of gastroenterology, breath tests (BTs) are used intermittently as diagnostic tools that allow indirect, non-invasive and relatively less cumbersome evaluation of several disorders by simply quantifying the appearance in exhaled breath of a metabolite of a specific substrate administered. The aim of this review is to have an insight into the principles, methods of analysis and performance parameters of various hydrogen, methane and carbon BTs which are available for diagnosing gastrointestinal disorders such as Helicobacter pylori infection, small intestinal bacterial overgrowth, and carbohydrate malabsorption. Evaluation of gastric emptying is routinely performed by scintigraphy which is however, difficult to perform and not suitable for children and pregnant women, this review has abridged the 13C-octanoic acid test in comparison to scintigraphy and has emphasized on its working protocol and challenges. A new development such as electronic nose test is also highlighted. Moreover we have also explored the limitations and constraints restraining the wide use of these BT. We conclude that breath testing has an enormous potential to be used as a diagnostic modality. In addition it offers distinct advantages over the traditional invasive methods commonly employed. PMID:27574563

  14. Evaluation of 13CO2 breath tests for the detection of fructose malabsorption.

    PubMed

    Hoekstra, J H; van den Aker, J H; Kneepkens, C M; Stellaard, F; Geypens, B; Ghoos, Y F

    1996-03-01

    Breath hydrogen (H2) studies have made clear that small intestinal absorption of fructose is limited, especially in toddlers. Malabsorption of fructose may be a cause of recurrent abdominal pain and chronic nonspecific diarrhea (toddler's diarrhea). Fructose absorption is facilitated by equimolar doses of glucose and, as we have found, amino acids (especially L-alanine); the mechanism underlying this effect remains unclear. To study fructose absorption in a more direct way, we combined breath H2 studies with breath 13CO2 studies. Gastric emptying was studied by using L-glycine-1-13C in 4 children from 12.1 to 16.0 years of age. After 25 gm of fructose and 27.5 gm of glucose, when given together, gastric emptying was significantly (p<0.05) slower than with either sugar alone. In a second series of experiments, 5 children from 12.0 to 15.9 years of age were tested with 25 gm of fructose, alone and with equimolar doses of glucose and L-alanine, and 4 younger children from 3.1 to 6.1 years of age were tested with 2 gm/kg (max 37.5 gm) fructose, alone or with an equimolar dose of L-alanine. All fructose solutions were enriched with 15 mg of D-fructose-13C-6. In all 9 children, fructose was malabsorbed as judged by breath H2 increases > or = 20 ppm, and the addition of glucose or L-alanine resulted in significantly lower breath H2 increases (p < or = 0.005 for glucose, p < or = 0.001 for alanine). In contrast, the addition of alanine or glucose did not change the pattern of breath 13CO2 excretion in the 5 older children, whereas in the 4 younger children (with relatively higher doses), L-alanine addition resulted in significantly lower increases in breath 13CO2. In the latter group, for each time point, breath H2 and 13CO2 concentrations after fructose were compared with those after fructose plus L-alanine; in 20 out of 24 points, both H2 and 13CO2 were higher after fructose. These results suggest that 13CO2 not only originated from the oxidation of absorbed substrate but also, at least in part, from colonic bacterial metabolism. For the detection of [correction of or] fructose malabsorption--as opposed to, for instance, lactose--the 13CO2 breath test seems to be of limited value.

  15. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... fractional nitric oxide concentration in expired breath aids in evaluating an asthma patient's response to anti-inflammatory therapy, as an adjunct to established clinical and laboratory assessments of asthma...

  16. Lactose Intolerance (For Parents)

    MedlinePlus

    ... Doctors usually diagnose lactose intolerance through a simple hydrogen breath test. A person blows into a tube ... there is a higher than average level of hydrogen and methane in the breath. That's because undigested ...

  17. Fructose intake at current levels in the United States may cause gastrointestinal distress in normal adults.

    PubMed

    Beyer, Peter L; Caviar, Elena M; McCallum, Richard W

    2005-10-01

    Fructose intake has increased considerably in the United States, primarily as a result of increased consumption of high-fructose corn syrup, fruits and juices, and crystalline fructose. The purpose was to determine how often fructose, in amounts commonly consumed, would result in malabsorption and/or symptoms in healthy persons. Fructose absorption was measured using 3-hour breath hydrogen tests and symptom scores were used to rate subjective responses for gas, borborygmus, abdominal pain, and loose stools. The study included 15 normal, free-living volunteers from a medical center community and was performed in a gastrointestinal specialty clinic. Subjects consumed 25- and 50-g doses of crystalline fructose with water after an overnight fast on separate test days. Mean peak breath hydrogen, time of peak, area under the curve (AUC) for breath hydrogen and gastrointestinal symptoms were measured during a 3-hour period after subjects consumed both 25- and 50-g doses of fructose. Differences in mean breath hydrogen, AUC, and symptom scores between doses were analyzed using paired t tests. Correlations among peak breath hydrogen, AUC, and symptoms were also evaluated. More than half of the 15 adults tested showed evidence of fructose malabsorption after 25 g fructose and greater than two thirds showed malabsorption after 50 g fructose. AUC, representing overall breath hydrogen response, was significantly greater after the 50-g dose. Overall symptom scores were significantly greater than baseline after each dose, but scores were only marginally greater after 50 g than 25 g. Peak hydrogen levels and AUC were highly correlated, but neither was significantly related to symptoms. Fructose, in amounts commonly consumed, may result in mild gastrointestinal distress in normal people. Additional study is warranted to evaluate the response to fructose-glucose mixtures (as in high-fructose corn syrup) and fructose taken with food in both normal people and those with gastrointestinal dysfunction. Because breath hydrogen peaks occurred at 90 to 114 minutes and were highly correlated with 180-minute breath hydrogen AUC, the use of peak hydrogen measures may be considered to shorten the duration of the exam.

  18. Exercise-induced quadriceps muscle fatigue in men and women: effects of arterial oxygen content and respiratory muscle work.

    PubMed

    Dominelli, Paolo B; Molgat-Seon, Yannick; Griesdale, Donald E G; Peters, Carli M; Blouin, Jean-Sébastien; Sekhon, Mypinder; Dominelli, Giulio S; Henderson, William R; Foster, Glen E; Romer, Lee M; Koehle, Michael S; Sheel, A William

    2017-08-01

    High work of breathing and exercise-induced arterial hypoxaemia (EIAH) can decrease O 2 delivery and exacerbate exercise-induced quadriceps fatigue in healthy men. Women have a higher work of breathing during exercise, dedicate a greater fraction of whole-body V̇O2 towards their respiratory muscles and develop EIAH. Despite a greater reduction in men's work of breathing, the attenuation of quadriceps fatigue was similar between the sexes. The degree of EIAH was similar between sexes, and regardless of sex, those who developed the greatest hypoxaemia during exercise demonstrated the most attenuation of quadriceps fatigue. Based on our previous finding that women have a greater relative oxygen cost of breathing, women appear to be especially susceptible to work of breathing-related changes in quadriceps muscle fatigue. Reducing the work of breathing or eliminating exercise-induced arterial hypoxaemia (EIAH) during exercise decreases the severity of quadriceps fatigue in men. Women have a greater work of breathing during exercise, dedicate a greater fraction of whole-body V̇O2 towards their respiratory muscles, and demonstrate EIAH, suggesting women may be especially susceptible to quadriceps fatigue. Healthy subjects (8 male, 8 female) completed three constant load exercise tests over 4 days. During the first (control) test, subjects exercised at ∼85% of maximum while arterial blood gases and work of breathing were assessed. Subsequent constant load exercise tests were iso-time and iso-work rate, but with EIAH prevented by inspiring hyperoxic gas or work of breathing reduced via a proportional assist ventilator (PAV). Quadriceps fatigue was assessed by measuring force in response to femoral nerve stimulation. For both sexes, quadriceps force was equally reduced after the control trial (-27 ± 2% baseline) and was attenuated with hyperoxia and PAV (-18 ± 1 and -17 ± 2% baseline, P < 0.01, respectively), with no sex difference. EIAH was similar between the sexes, and regardless of sex, subjects with the lowest oxyhaemoglobin saturation during the control test had the greatest quadriceps fatigue attenuation with hyperoxia (r 2  = 0.79, P < 0.0001). For the PAV trial, despite reducing the work of breathing to a greater degree in men (men: 60 ± 5, women: 75 ± 6% control, P < 0.05), the attenuation of quadriceps fatigue was similar between the sexes (36 ± 4 vs. 37 ± 7%). Owing to a greater relative V̇O2 of the respiratory muscles in women, less of a change in work of breathing is needed to reduce quadriceps fatigue. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.

  19. A probability-based multi-cycle sorting method for 4D-MRI: A simulation study.

    PubMed

    Liang, Xiao; Yin, Fang-Fang; Liu, Yilin; Cai, Jing

    2016-12-01

    To develop a novel probability-based sorting method capable of generating multiple breathing cycles of 4D-MRI images and to evaluate performance of this new method by comparing with conventional phase-based methods in terms of image quality and tumor motion measurement. Based on previous findings that breathing motion probability density function (PDF) of a single breathing cycle is dramatically different from true stabilized PDF that resulted from many breathing cycles, it is expected that a probability-based sorting method capable of generating multiple breathing cycles of 4D images may capture breathing variation information missing from conventional single-cycle sorting methods. The overall idea is to identify a few main breathing cycles (and their corresponding weightings) that can best represent the main breathing patterns of the patient and then reconstruct a set of 4D images for each of the identified main breathing cycles. This method is implemented in three steps: (1) The breathing signal is decomposed into individual breathing cycles, characterized by amplitude, and period; (2) individual breathing cycles are grouped based on amplitude and period to determine the main breathing cycles. If a group contains more than 10% of all breathing cycles in a breathing signal, it is determined as a main breathing pattern group and is represented by the average of individual breathing cycles in the group; (3) for each main breathing cycle, a set of 4D images is reconstructed using a result-driven sorting method adapted from our previous study. The probability-based sorting method was first tested on 26 patients' breathing signals to evaluate its feasibility of improving target motion PDF. The new method was subsequently tested for a sequential image acquisition scheme on the 4D digital extended cardiac torso (XCAT) phantom. Performance of the probability-based and conventional sorting methods was evaluated in terms of target volume precision and accuracy as measured by the 4D images, and also the accuracy of average intensity projection (AIP) of 4D images. Probability-based sorting showed improved similarity of breathing motion PDF from 4D images to reference PDF compared to single cycle sorting, indicated by the significant increase in Dice similarity coefficient (DSC) (probability-based sorting, DSC = 0.89 ± 0.03, and single cycle sorting, DSC = 0.83 ± 0.05, p-value <0.001). Based on the simulation study on XCAT, the probability-based method outperforms the conventional phase-based methods in qualitative evaluation on motion artifacts and quantitative evaluation on tumor volume precision and accuracy and accuracy of AIP of the 4D images. In this paper the authors demonstrated the feasibility of a novel probability-based multicycle 4D image sorting method. The authors' preliminary results showed that the new method can improve the accuracy of tumor motion PDF and the AIP of 4D images, presenting potential advantages over the conventional phase-based sorting method for radiation therapy motion management.

  20. Breathing metabolic simulator.

    NASA Technical Reports Server (NTRS)

    Bartlett, R. G., Jr.; Hendricks, C. M.; Morison, W. B.

    1971-01-01

    Description of a device for simulation of the human breathing and metabolic parameters required for the evaluation of respiratory diagnostic, monitoring, support and resuscitation equipment. The remotely controlled device allows wide variations in breathing rate and depth, breath velocity contour, oxygen uptake and carbon dioxide release to simulate conditions from sleep to hard work, with respiration exchange ratios ranging from hypoventilation to hyperventilation. It also reduces the cost of prolonged testing when simulation chambers with human subjects require three shifts of crews and standby physicians. Several block diagrams of the device and subsystems are given.

  1. Diagnosis of acute respiratory distress syndrome by exhaled breath analysis

    PubMed Central

    2018-01-01

    The acute respiratory distress syndrome (ARDS) is a complication of critical illness that is characterized by acute onset, protein rich, pulmonary edema. There is no treatment for ARDS, other than the reduction of additional ventilator induced lung injury. Prediction or earlier recognition of ARDS could result in preventive measurements and might decrease mortality and morbidity. Exhaled breath contains volatile organic compounds (VOCs), a collection of hundreds of small molecules linked to several physiological and pathophysiological processes. Analysis of exhaled breath through gas-chromatography and mass-spectrometry (GC-MS) has resulted in an accurate diagnosis of ARDS in several studies. Most identified markers are linked to lipid peroxidation. Octane is one of the few markers that was validated as a marker of ARDS and is pathophysiologically likely to be increased in ARDS. None of the currently studied breath analysis methods is directly applicable in clinical practice. Two steps have to be taken before any breath test can be allowed into the intensive care unit. External validation in a multi-center study is a prerequisite for any of the candidate breath markers and the breath test should outperform clinical prediction scores. Second, the technology for breath analysis should be adapted so that it is available at a decentralized lab inside the intensive care unit and can be operated by trained nurses, in order to reduce the analysis time. In conclusion, exhaled analysis might be used for the early diagnosis and prediction of ARDS in the near future but several obstacles have to be taken in the coming years. Most of the candidate markers can be linked to lipid peroxidation. Only octane has been validated in a temporal external validation cohort and is, at this moment, the top-ranking breath biomarker for ARDS. PMID:29430450

  2. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing.

    PubMed

    Donaldsson, Snorri; Falk, Markus; Jonsson, Baldvin; Drevhammar, Thomas

    2015-01-01

    The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates.

  3. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing

    PubMed Central

    2015-01-01

    Background The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Methods Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. Results The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. Conclusion The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates. PMID:26192188

  4. DEVELOPMENT OF A SCREENING PROTOCOL TO IDENTIFY INDIVIDUALS WITH DYSFUNCTIONAL BREATHING

    PubMed Central

    Kiesel, Kyle; Rhodes, Tonya; Mueller, Jacob; Waninger, Alyssa; Butler, Robert

    2017-01-01

    Introduction Dysfunctional breathing (DB) has been linked to health conditions including low back pain and neck pain and adversely effects the musculoskeletal system. Individuals with DB often have decreased pain thresholds and impaired motor control, balance, and movement. No single test or screen identifies DB, which is multi-dimensional, and includes biochemical, biomechanical, and psychophysiological components. Several tools assess and test for DB, but no screen exists to determine whether additional testing and assessment are indicated. Purpose/Background The purpose of this study was to develop a breathing screening procedure that could be utilized by fitness and healthcare providers to screen for the presence of disordered breathing. A diagnostic test study approach was utilized to establish the diagnostic accuracy of the newly developed screen for DB. Methods A convenience sample of 51 subjects (27 females, 27.0 years, BMI 23.3) were included. To test for DB related to the biochemical dimension, end-tidal CO2 (ETCO2) was measured with a capnography unit. To test for DB related to biomechanical dimension, the Hi-Lo test was utilized. To test for DB related to the psychophysiological dimension, the Self Evaluation of Breathing Symptoms Questionnaire (SEBQ) and Nijmegen questionnaires were utilized. Potential screening items that have been shown to be related to DB in previous research and that could be performed by non-health care personnel were utilized to create the index test including activity level, breath hold time (BHT), respiration rate, and the Functional Movement Screen (FMS™). Results There were no strong correlations between the three measures of DB. Five subjects had normal breathing, 14 failed at least one measure, 20 failed at least two, and 12 failed all three. To develop screening items for each dimension, data were examined for association with failure. BHT and a four-item mini-questionnaire were identified as the most closely associated variables with failure of all three dimensions. A BHT of < 25 seconds and four questions were combined and yielded a sensitivity of 0.89 (0.85-0.93) and a specificity of 0.60 (0.18-0.92) for clinical identification of DB. Conclusion Easily obtained clinical measures of BHT and four questions can be utilized to screen for the presence of DB. If the screen is passed, there is an 89% chance that DB is not present. If the screen is failed, further assessment is recommended. Level of Evidence 2b PMID:29181255

  5. Detection of Δ9-tetrahydrocannabinol in exhaled breath collected from cannabis users.

    PubMed

    Beck, Olof; Sandqvist, Sören; Dubbelboer, Ilse; Franck, Johan

    2011-10-01

    Exhaled breath has recently been proposed as a new possible matrix for drugs of abuse testing. A key drug is cannabis, and the present study was aimed at investigating the possibility of detecting tetrahydrocannabinol and tetrahydrocannabinol carboxylic acid in exhaled breath after cannabis smoking. Exhaled breath was sampled from 10 regular cannabis users and 8 controls by directing the exhaled breath by suction through an Empore C(18) disk. The disk was extracted with hexane/ethyl acetate, and the resulting extract was evaporated to dryness and redissolved in 100 μL hexane/ethyl acetate. A 3-μL aliquot was injected onto the LC-MS-MS system and analyzed using positive electrospray ionization and selected reaction monitoring. In samples collected 1-12 h after cannabis smoking, tetrahydrocannabinol was detected in all 10 subjects. The rate of excretion was between 9.0 and 77.3 pg/min. Identification of tetrahydrocannabinol was based on correct retention time relative to tetrahydrocannabinol-d(3) and correct product ion ratio. In three samples, peaks were observed for tetrahydrocannabinol carboxylic acid, but these did not fulfill identification criteria. Neither tetrahydrocannabinol or tetrahydrocannabinol carboxylic acid was detected in the controls. These results confirm older reports that tetrahydrocannabinol is present in exhaled breath following cannabis smoking and extend the detection time from minutes to hours. The results further support the idea that exhaled breath is a promising matrix for drugs-of-abuse testing.

  6. An automated system for pulmonary function testing

    NASA Technical Reports Server (NTRS)

    Mauldin, D. G.

    1974-01-01

    An experiment to quantitate pulmonary function was accepted for the space shuttle concept verification test. The single breath maneuver and the nitrogen washout are combined to reduce the test time. Parameters are defined from the forced vital capacity maneuvers. A spirometer measures the breath volume and a magnetic section mass spectrometer provides definition of gas composition. Mass spectrometer and spirometer data are analyzed by a PDP-81 digital computer.

  7. [Breath alcohol test in construction sites in the Province of Belluno: a campaign in favour of health promotion and surveillance and against drinking].

    PubMed

    Marcolina, Daniela; De Marzo, Nicoletta; Riccio, Maria Teresa

    2011-01-01

    Health impairment due to alcohol use and abuse is well known, in terms of relationship with traffic accidents and work accidents. In Italy almost 10 per cent of accidents at work involve intoxicated people injuring themselves and innocent victims. Alcohol abuse is a factor involved in determining severe accidents in the construction industry and epidemiological studies demonstrated a relationship between an elevated alcohol use and severity of accidents. Since in the Province of Belluno alcohol consumption may be elevated also at work, the two Occupational Health Units (SPISAL) in the province organized a campaign of information and surveillance against alcohol consumption at work in the construction industry. This report shows the campaign results, mainly in terms of breath alcohol tests performed in construction workers. After an extensive information campaign we inspected 50 sites, where 105 construction companies were at work, and tested 294 workers by breath alcohol test. No-one refused the test. Only 2.7% construction workers were positive for the breath alcohol test, and the levels were not elevated. This study shows that the construction workers in Belluno Province are responsible drinkers and are well aware of the policy of prohibition of alcohol consumption at work.

  8. Diffuse Interstitial Brain Edema in Patients With End-Stage Renal Disease Undergoing Hemodialysis: A Tract-Based Spatial Statistics Study

    PubMed Central

    Kong, Xiang; Wen, Ji-qiu; Qi, Rong-feng; Luo, Song; Zhong, Jian-hui; Chen, Hui-juan; Ji, Gong-jun; Lu, Guang Ming; Zhang, Long Jiang

    2014-01-01

    Abstract To investigate white matter (WM) alterations and their correlation with cognition function in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD) using diffusion tensor imaging (DTI) with tract-based spatial statistics (TBSS) approach. This prospective HIPAA-complaint study was approved by our institutional review board. Eighty HD ESRD patients and 80 sex- and age-matched healthy controls were included. Neuropsychological (NP) tests and laboratory tests, including serum creatinine and urea, were performed. DTI data were processed to obtain fractional anisotropy (FA) and mean diffusivity (MD) maps with TBSS. FA and MD difference between the 2 groups were compared. We also explored the associations of FA values in WM regions of lower FA with ages, NP tests, disease, and dialysis durations, serum creatinine and urea levels of ESRD patients. Compared with controls, HD ESRD patients had lower FA value in the corpus callosum, bilateral corona radiate, posterior thalamic radiation, left superior longitudinal fasciculus, and right cingulum (P < 0.05, FWE corrected). Almost all WM regions had increased MD in HD ESRD patients compared with controls (P < 0.05, FWE corrected). In some regions with lower FA, FA values showed moderate correlations with ages, NP tests, and serum urea levels. There was no correlation between FA values and HD durations, disease durations, and serum creatinine levels of ESRD patients (all P > 0.05). Diffuse interstitial brain edema and moderate WM integrity disruption occurring in HD ESRD patients, which correlated with cognitive dysfunction, and serum urea levels might be a risk factor for these WM changes. PMID:25526483

  9. Blood Urea Nitrogen Test

    MedlinePlus

    ... Free Fetal DNA Cerebrospinal Fluid (CSF) Analysis Ceruloplasmin Chemistry Panels Chickenpox and Shingles Tests Chlamydia Testing Chloride ... mmol/L 1 from Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. Burtis CA, Ashwood ER, Bruns ...

  10. Relationships between Circulating Urea Concentrations and Endometrial Function in Postpartum Dairy Cows.

    PubMed

    Cheng, Zhangrui; Oguejiofor, Chike F; Swangchan-Uthai, Theerawat; Carr, Susan; Wathes, D Claire

    2015-08-14

    Both high and low circulating urea concentrations, a product of protein metabolism, are associated with decreased fertility in dairy cows through poorly defined mechanisms. The rate of involution and the endometrial ability to mount an adequate innate immune response after calving are both critical for subsequent fertility. Study 1 used microarray analysis to identify genes whose endometrial expression 2 weeks postpartum correlated significantly with the mean plasma urea per cow, ranging from 3.2 to 6.6 mmol/L. The biological functions of 781 mapped genes were analysed using Ingenuity Pathway Analysis. These were predominantly associated with tissue turnover (e.g., BRINP1, FOXG1), immune function (e.g., IL17RB, CRISPLD2), inflammation (e.g., C3, SERPINF1, SERPINF2) and lipid metabolism (e.g., SCAP, ACBD5, SLC10A). Study 2 investigated the relationship between urea concentration and expression of 6 candidate genes (S100A8, HSP5A, IGF1R, IL17RB, BRINP1, CRISPLD2) in bovine endometrial cell culture. These were treated with 0, 2.5, 5.0 or 7.5 mmol/L urea, equivalent to low, medium and high circulating values with or without challenge by bacterial lipopolysaccharide (LPS). LPS increased S100A8 expression as expected but urea treatment had no effect on expression of any tested gene. Examination of the genes/pathways involved suggests that plasma urea levels may reflect variations in lipid metabolism. Our results suggest that it is the effects of lipid metabolism rather than the urea concentration which probably alter the rate of involution and innate immune response, in turn influencing subsequent fertility.

  11. Oxidation of urea-derived nitrogen by thaumarchaeota-dominated marine nitrifying communities.

    PubMed

    Tolar, Bradley B; Wallsgrove, Natalie J; Popp, Brian N; Hollibaugh, James T

    2017-12-01

    Urea nitrogen has been proposed to contribute significantly to nitrification by marine thaumarchaeotes. These inferences are based on distributions of thaumarchaeote urease genes rather than activity measurements. We found that ammonia oxidation rates were always higher than oxidation rates of urea-derived N in samples from coastal Georgia, USA (means ± SEM: 382 ± 35 versus 73 ± 24 nmol L -1  d -1 , Mann-Whitney U-test p < 0.0001), and the South Atlantic Bight (20 ± 8.8 versus 2.2 ± 1.7 nmol L -1  d -1 , p = 0.026) but not the Gulf of Alaska (8.8 ± 4.0 versus 1.5 ± 0.6, p > 0.05). Urea-derived N was relatively more important in samples from Antarctic continental shelf waters, though the difference was not statistically significant (19.4 ± 4.8 versus 12.0 ± 2.7 nmol L -1  d -1 , p > 0.05). We found only weak correlations between oxidation rates of urea-derived N and the abundance or transcription of putative Thaumarchaeota ureC genes. Dependence on urea-derived N does not appear to be directly related to pH or ammonium concentrations. Competition experiments and release of 15 NH 3 suggest that urea is hydrolyzed to ammonia intracellularly, then a portion is lost to the dissolved pool. The contribution of urea-derived N to nitrification appears to be minor in temperate coastal waters, but may represent a significant portion of the nitrification flux in Antarctic coastal waters. © 2016 The Authors. Environmental Microbiology published by Society for Applied Microbiology and John Wiley & Sons Ltd.

  12. On the Creation, Utility and Sustaining of Rare Diseases Research Networks: Lessons learned from the Urea Cycle Disorders Consortium, the Japanese Urea Cycle Disorders Consortium and the European Registry and Network for Intoxication Type Metabolic Diseases.

    PubMed

    Summar, Marshall L; Endo, Fumio; Kölker, Stefan

    2014-01-01

    The past two decades has seen a rapid expansion in the scientific and public interest in rare diseases and their treatment. One consequence of this has been the formation of registries/longitudinal natural history studies for these disorders. Given the expense and effort needed to develop and maintain such programs, we describe our experience with three linked registries on the same disease group, urea cycle disorders. The Urea Cycle Disorders Consortium (UCDC) was formed in the U.S. in 2003 in response to a request for application from the National Institutes of Health (NIH); the European Registry and Network for Intoxication Type Metabolic Diseases (E-IMD) was formed in 2011 in response to a request for applications from the Directorate-General for Health and Consumers (DG SANCO) of the EU; and the Japanese Urea Cycle Disorders Consortium (JUCDC) was founded in 2012 as a sister organization to the UCDC and E-IMD. The functions of these groups are to collect natural history data, educate the professional and lay population, develop and test new treatments, and establish networks of excellence for the care for these disorders. The UCDC and JUCDC focus exclusively on urea cycle disorders while the E-IMD includes patients with urea cycle disorders and organic acidurias. More than 1400 patients have been enrolled in the three consortia, and numerous projects have been developed and joint meetings held including an international UCDC/E-IMD/JUCDC Urea Cycle meeting in Barcelona in 2013. This article summarizes some of the experiences from the three groups regarding formation, funding, and models for sustainability. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. On the Creation, Utility and Sustaining of Rare Diseases Research Networks: Lessons learned from the Urea Cycle Disorders Consortium, the Japanese Urea Cycle Disorders Consortium and the European Registry and Network for Intoxication Type Metabolic Diseases

    PubMed Central

    Summar, Marshall L.; Endo, Fumio; Kölker, Stefan

    2016-01-01

    The past two decades has seen a rapid expansion in the scientific and public interest in rare diseases and their treatment. One consequence of this has been the formation of registries/longitudinal natural history studies for these disorders. Given the expense and effort needed to develop and maintain such programs, we describe our experience with three linked registries on the same disease group, urea cycle disorders. The Urea Cycle Disorders Consortium (UCDC) was formed in the U.S. in 2003 in response to a request for application from the National Institutes of Health (NIH); the European Registry and Network for Intoxication Type Metabolic Diseases (E-IMD) was formed in 2011 in response to a request for applications from the Directorate-General for Health and Consumers (DG SANCO) of the EU; and the Japanese Urea Cycle Disorders Consortium (JUCDC) was founded in 2012 as a sister organization to the UCDC and E-IMD. The functions of these groups are to collect natural history data, educate the professional and lay population, develop and test new treatments, and establish networks of excellence for the care for these disorders. The UCDC and JUCDC focus exclusively on urea cycle disorders while the E-IMD includes patients with urea cycle disorders and organic acidurias. More than 1400 patients have been enrolled in the three consortia, and numerous projects have been developed and joint meetings held including an international UCDC/E-IMD/JUCDC Urea Cycle meeting in Barcelona in 2013. This article summarizes some of the experiences from the three groups regarding formation, funding, and models for sustainability. PMID:25261246

  14. [Modeling the ammonia volatilization from common urea and controlled releasing urea fertilizers in paddy soil of Taihui region of China by Jayaweera-Mikkelsen model].

    PubMed

    Li, Hui-lin; Han, Yong; Cai, Zu-cong

    2008-04-01

    The ammonia volatilization on the Typic Gleyi-stagnic Anthrosol with application of common urea and controlled release urea (LP-S100) fertilizers in the rice seasons in paddy soil of Taihui region of China was modeled by Jayaweera-Mikkelsen model. Results showed great difference of ammonia volatilization from two type fertilizers was detected with lysimeter experiment in the rice season. Nitrogen loss via ammonia volatilization after common urea application with conventional ways was 29%-35%, while only 5% of controlled release urea-N was volatilized. The Jayaweera-Mikkelsen model was over estimated the total amount of ammonia volatilization in the whole season, and great deviation from the measured data was obvious for the higher volatilization from common urea fertilizer. The estimated data were 2.95-4.19 times of the measures one for common urea treatments, while they were 1.19-1.40 times of those measured for LP-S100 treatments. The order of magnitude quotient was one of the indicators to evaluate the model estimation. The value of it was 0.8, which indicated the estimation of the model need improvement. Though sensitive analysis for the five parameters in the model was tested and amended the parameter of the concentration of NH4+ -N, a limited term was inducted in the model operation. The amended model got better results as the ratio of estimation to measured data was decreased to 1.12-1.28. The alga activity in the paddy field influenced ammonia volatilization and might make the failure of the model estimation of the original model.

  15. Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging

    NASA Technical Reports Server (NTRS)

    Ramirez, M. P.; Sigaloff, K. C.; Kubatina, L. V.; Donahue, M. A.; Venkatesh, A. K.; Albert, M. S.; ALbert, M. S. (Principal Investigator)

    2000-01-01

    The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.

  16. Experimental and modeling study of thermal exposure of a self-contained breathing apparatus (SCBA).

    PubMed

    Donnelly, Michelle K; Yang, Jiann C

    2015-08-01

    An experimental apparatus designed to study firefighter safety equipment exposed to a thermal environment was developed. The apparatus consisted of an elevated temperature flow loop with the ability to heat the air stream up to 200°C. The thermal and flow conditions at the test section were characterized using thermocouples and bi-directional probes. The safety equipment examined in this study was a self-contained breathing apparatus (SCBA), including a facepiece and an air cylinder. The SCBA facepiece was placed on a mannequin headform and coupled to a breathing simulator that was programmed with a prescribed breathing pattern. The entire SCBA assembly was placed in the test section of the flow loop for these thermal exposure experiments. Three air stream temperatures, 100°C, 150°C, and 200°C, were used with the average air speed at the test section set at 1.4m/s and thermal exposure durations up to 1200 s. Measurements were made using type-K bare-bead thermocouples located in the mannequin's mouth and on the outer surface of the SCBA cylinder. The experimental results indicated that increasing the thermal exposure severity and duration increased the breathing air temperatures supplied by the SCBA. Temperatures of breathing air from the SCBA cylinder in excess of 60°C were observed over the course of the thermal exposure conditions used in most of the experiments. A mathematical model for transient heat transfer was developed to complement the thermal exposure experimental study. The model took into consideration forced convective heat transfer, quasi-steady heat conduction through the composite layers of the SCBA cylinder wall, the breathing pattern and action of the breathing simulator, and predicted air temperatures from the thermally exposed SCBA cylinder and temperatures at the outer surface of the SCBA cylinder. Model predictions agreed reasonably well with the experimental measurements. Published by Elsevier Ltd.

  17. Breath test refusals

    DOT National Transportation Integrated Search

    2007-11-01

    The National Highway Traffic Safety Administration has found that the percentage of people who refuse to provide breath samples when arrested for Driving While Intoxicated (DWI) varies considerably across States, and this creates a concern in the cri...

  18. (13)C breath tests in personalized medicine: fiction or reality?

    PubMed

    Modak, Anil S

    2009-11-01

    The concept of personalized medicine is gathering momentum as various biomarkers are being discovered and developed to lead to genotype and phenotype diagnostic tests, which will enable physicians to individualize therapy. Noninvasive, rapid (13)C breath tests have the potential to serve as clinically significant diagnostic tools, especially for evaluating the enzyme activity of polymorphic enzymes. This would enable physicians to rapidly identify responders/nonresponders to various drugs primarily metabolized by these enzymes prior to initiation of therapy. With the information on enzyme activity, the physician can prescribe the right drug, at the right dose, at the right time, to the right individual, for the right clinical outcome. However, the promise of the era of personalized medicine, including the novel (13)C breath tests, will have to overcome several regulatory, business and financial hurdles for diagnostic tests to become part of routine mainstream clinical practice over the next decade.

  19. Effects of pretreatment with a urea-containing emollient on nickel allergic skin reactions.

    PubMed

    Kuzmina, Natalia; Nyrén, Miruna; Lodén, Marie; Edlund, Fredrik; Emtestam, Lennart

    2005-01-01

    The aim of this study was to evaluate the effect of a moisturizer containing urea on allergic contact dermatitis. Twenty-five nickel-sensitized patients and five controls (non-sensitized volunteers) applied such a moisturizer on the volar side of one forearm twice daily for 20 days, while the other forearm served as the control. After treatment with the moisturizer, patch tests with 0%, 0.5% and 2% NiSO4 in petrolatum were applied in a randomized manner on each arm. After 72 h, the skin reactions were blindly evaluated by clinical scoring and by measuring transepidermal water loss and electrical impedance. After treatment, the baseline transepidermal water loss values were lower and the baseline magnitude impedance index values were higher on the pretreated forearm. According to clinical scoring and measurements with the two physical measurement techniques, the degree of the patch test reactions was equal. All control subjects had negative nickel tests. We concluded that the skin reactivity to nickel in nickel-sensitized patients is not significantly affected by use of the urea-containing moisturizer.

  20. Quiet breathing in hindlimb casted mice.

    PubMed

    Receno, Candace N; Roffo, Katelynn E; Mickey, Marisa C; DeRuisseau, Keith C; DeRuisseau, Lara R

    2018-06-07

    The hindlimb casting model was developed to study skeletal muscle reloading following a period of unloading. It is unknown if ventilation parameters of mice are affected by the casting model. We tested the hypothesis that hindlimb casted mice have similar ventilatory patterns compared to mice with the casts removed. Male CD-1 mice underwent 14 days of hindlimb immobilization via plaster casting. Breathing parameters were obtained utilizing unrestrained barometric plethysmography (UBP). Breathing traces were analyzed with Ponemah software for breathing frequency, tidal volume (TV), and minute ventilation (MV). Frequency, TV and MV did not show any differences in quiet breathing patterns during or post-casting in mice. Thus, the hindlimb casting model does not complicate breathing during and after casting and should not interfere with the unloading and reloading of skeletal muscle. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Comparison of breath gases, including acetone, with blood glucose and blood ketones in children and adolescents with type 1 diabetes.

    PubMed

    Blaikie, Tom P J; Edge, Julie A; Hancock, Gus; Lunn, Daniel; Megson, Clare; Peverall, Rob; Richmond, Graham; Ritchie, Grant A D; Taylor, David

    2014-11-25

    Previous studies have suggested that breath gases may be related to simultaneous blood glucose and blood ketone levels in adults with type 2 and type 1 diabetes. The aims of this study were to investigate these relationships in children and young people with type 1 diabetes in order to assess the efficacy of a simple breath test as a non-invasive means of diabetes management. Gases were collected in breath bags and measurements were compared with capillary blood glucose and ketone levels taken at the same time on a single visit to a routine hospital clinic in 113 subjects (59 male, age 7 years 11 months-18 years 3 months) with type 1 diabetes. The patients were well-controlled with relatively low concentrations of the blood ketone measured (β hydroxybutyrate, 0-0.4 mmol l(-1)). Breath acetone levels were found to increase with blood β hydroxybutyrate levels and a significant relationship was found between the two (Spearman's rank correlation ρ = 0.364, p < 10(-4)). A weak positive relationship was found between blood glucose and breath acetone (ρ = 0.16, p = 0.1), but led to the conclusion that single breath measurements of acetone do not provide a good measure of blood glucose levels in this cohort. This result suggests a potential to develop breath gas analysis to provide an alternative to blood testing for ketone measurement, for example to assist with the management of type 1 diabetes.

  2. Effect of influenza vaccination on oxidative stress products in breath.

    PubMed

    Phillips, Michael; Cataneo, Renee N; Chaturvedi, Anirudh; Danaher, Patrick J; Devadiga, Anantrai; Legendre, David A; Nail, Kim L; Schmitt, Peter; Wai, James

    2010-06-01

    Viral infections cause increased oxidative stress, so a breath test for oxidative stress biomarkers (alkanes and alkane derivatives) might provide a new tool for early diagnosis. We studied 33 normal healthy human subjects receiving scheduled treatment with live attenuated influenza vaccine (LAIV). Each subject was his or her own control, since they were studied on day 0 prior to vaccination, and then on days 2, 7 and 14 following vaccination. Breath volatile organic compounds (VOCs) were collected with a breath collection apparatus, then analyzed by automated thermal desorption with gas chromatography and mass spectroscopy. A Monte Carlo simulation technique identified non-random VOC biomarkers of infection based on their C-statistic values (area under curve of receiver operating characteristic). Treatment with LAIV was followed by non-random changes in the abundance of breath VOCs. 2, 8-Dimethyl-undecane and other alkane derivatives were observed on all days. Conservative multivariate models identified vaccinated subjects on day 2 (C-statistic = 0.82, sensitivity = 63.6% and specificity = 88.5%); day 7 (C-statistic = 0.94, sensitivity = 88.5% and specificity = 92.3%); and day 14 (C-statistic = 0.95, sensitivity = 92.3% and specificity = 92.3%). The altered breath VOCs were not detected in live attenuated influenza vaccine, excluding artifactual contamination. LAIV vaccination in healthy humans elicited a prompt and sustained increase in breath biomarkers of oxidative stress. A breath test for these VOCs could potentially identify humans who are acutely infected with influenza, but who have not yet developed clinical symptoms or signs of disease.

  3. [Frequency of rhinitis and orofacial disorders in patients with dental malocclusion].

    PubMed

    Imbaud, Tamara Christine de Souza; Mallozi, Márcia Carvalho; Domingos, Vanda Beatriz Teixeira Coelho; Solé, Dirceu

    2016-06-01

    To describe the frequency and etiology of rhinitis, oral breathing, types of malocclusion and orofacial disorders in patients treated for dental malocclusion. Patients with poor dental occlusion (n=89, 8-15 years) undergoing orthodontic treatment at the Postgraduate Orthodontics Center (Sao Paulo, Brazil) participated in the study. Rhinitis and oral breathing were diagnosed by anamnesis, clinical assessment and allergic etiology of rhinitis through immediate hypersensitivity skin prick test (SPT) with airborne allergens. The association between types of breathing (oral or nasal), rhinitis and types of dental malocclusion, bruxism and cephalometric alterations (increased Y axis of facial growth) compared to standard cephalometric tracing (Escola de Odontologia da Universidade de São Paulo) were assessed. The frequency of rhinitis in patients with dental malocclusion was 76.4% (68), and, of these, 81.7% were allergic (49/60 positive skin prick test), whereas the frequency of oral breathing was 62.9%. There was a significant association between an increased Y axis of facial growth and oral breathing (p<0.001), as well as between oral breathing and rhinitis (p=0.009). There was no association between rhinitis and bruxism. The frequency of rhinitis in children with dental malocclusion is higher than that in the general population, which is approximately 30%. Patients with oral breathing have a tendency to a dolichofacial growth pattern (increased Y axis of facial growth). In patients with rhinitis, regardless of the presence of oral breathing, the dolichofacial growth tendency was not observed. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  4. Do elite breath-hold divers suffer from mild short-term memory impairments?

    PubMed

    Billaut, François; Gueit, Patrice; Faure, Sylvane; Costalat, Guillaume; Lemaître, Frédéric

    2018-03-01

    Repeated apneas are associated with severe hypoxemia that may ultimately lead to loss of consciousness in some breath-hold divers. Despite increasing number of practitioners, the relationship between apnea-induced hypoxia and neurocognitive functions is still poorly understood in the sport of free diving. To shed light onto this phenomenon, we examined the impact of long-term breath-hold diving training on attentional processing, short-term memory, and long-term mnesic and executive functions. Thirty-six men matched for age, height, and weight were separated into the following 3 groups: (i) 12 elite breath-hold divers (EBHD), mean static apnea best time 371 s, 105 months mean apnea experience; (ii) 12 novice breath-hold divers, mean best time 243 s, 8.75 months mean apnea experience; and (iii) 12 physical education students with no breath-hold diving experience; all of these participants performed varied written and computerized neuropsychological tasks. Compared with the 2 other groups, the EBHD group was slower to complete the interference card during a Stroop test (F [1,33] = 4.70, p < 0.05), and presented more errors on the interference card (F [1,33] = 2.96, p < 0.05) and a lower total interference score (F [1,33] = 5.64, p < 0.05). The time to complete the interference card test was positively correlated with maximal static apnea duration (r = 0.73, p < 0.05) and the number of years of breath-hold diving training (r = 0.79, p < 0.001). These findings suggest that breath-hold diving training over several years may cause mild, but persistent, short-term memory impairments.

  5. Medullary cystic kidney disease

    MedlinePlus

    ... Tests that may be done include: 24-hour urine volume and electrolytes Blood urea nitrogen (BUN) Complete blood count (CBC) Creatinine blood test Creatinine clearance -- blood and urine Uric acid blood test Urine specific gravity (will ...

  6. Getting the Facts on Food Allergy Testing

    MedlinePlus

    ... ing, vomiting or trouble breathing after eating or coming into contact with a certain food, you may ... swelling, vomiting or trouble breathing after eating or coming into contact with certain foods, it’s important to ...

  7. A dual mode breath sampler for the collection of the end-tidal and dead space fractions.

    PubMed

    Salvo, P; Ferrari, C; Persia, R; Ghimenti, S; Lomonaco, T; Bellagambi, F; Di Francesco, F

    2015-06-01

    This work presents a breath sampler prototype automatically collecting end-tidal (single and multiple breaths) or dead space air fractions (multiple breaths). This result is achieved by real time measurements of the CO2 partial pressure and airflow during the expiratory and inspiratory phases. Suitable algorithms, used to control a solenoid valve, guarantee that a Nalophan(®) bag is filled with the selected breath fraction even if the subject under test hyperventilates. The breath sampler has low pressure drop (<0.5 kPa) and uses inert or disposable components to avoid bacteriological risk for the patients and contamination of the breath samples. A fully customisable software interface allows a real time control of the hardware and software status. The performances of the breath sampler were evaluated by comparing (a) the CO2 partial pressure calculated during the sampling with the CO2 pressure measured off-line within the Nalophan(®) bag; (b) the concentrations of four selected volatile organic compounds in dead space, end-tidal and mixed breath fractions. Results showed negligible deviations between calculated and off-line CO2 pressure values and the distributions of the selected compounds into dead space, end-tidal and mixed breath fractions were in agreement with their chemical-physical properties. Copyright © 2015. Published by Elsevier Ltd.

  8. Respiratory muscle function in infants with spinal muscular atrophy type I.

    PubMed

    Finkel, Richard S; Weiner, Daniel J; Mayer, Oscar H; McDonough, Joseph M; Panitch, Howard B

    2014-12-01

    To determine the feasibility and safety of respiratory muscle function testing in weak infants with a progressive neuromuscular disorder. Respiratory insufficiency is the major cause of morbidity and mortality in infants with spinal muscular atrophy type I (SMA-I). Tests of respiratory muscle strength, endurance, and breathing patterns can be performed safely in SMA-I infants. Useful data can be collected which parallels the clinical course of pulmonary function in SMA-I. An exploratory study of respiratory muscle function testing and breathing patterns in seven infants with SMA-I seen in our neuromuscular clinic. Measurements were made at initial study visit and, where possible, longitudinally over time. We measured maximal inspiratory (MIP) and transdiaphragmatic pressures, mean transdiaphragmatic pressure, airway occlusion pressure at 100 msec of inspiration, inspiratory and total respiratory cycle time, and aspects of relative thoracoabdominal motion using respiratory inductive plethysmography (RIP). The tension time index of the diaphragm and of the respiratory muscles, phase angle (Φ), phase relation during the total breath, and labored breathing index were calculated. Age at baseline study was 54-237 (median 131) days. Reliable data were obtained safely for MIP, phase angle, labored breathing index, and the invasive and non-invasive tension time indices, even in very weak infants. Data obtained corresponded to the clinical estimate of severity and predicted the need for respiratory support. The testing employed was both safe and feasible. Measurements of MIP and RIP are easily performed tests that are well tolerated and provide clinically useful information for infants with SMA-I. © 2014 Wiley Periodicals, Inc.

  9. Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: a systematic review and meta-analysis

    PubMed Central

    El Shayeb, Mohamed; Topfer, Leigh-Ann; Stafinski, Tania; Pawluk, Lawrence; Menon, Devidas

    2014-01-01

    Background: Greater awareness of sleep-disordered breathing and rising obesity rates have fueled demand for sleep studies. Sleep testing using level 3 portable devices may expedite diagnosis and reduce the costs associated with level 1 in-laboratory polysomnography. We sought to assess the diagnostic accuracy of level 3 testing compared with level 1 testing and to identify the appropriate patient population for each test. Methods: We conducted a systematic review and meta-analysis of comparative studies of level 3 versus level 1 sleep tests in adults with suspected sleep-disordered breathing. We searched 3 research databases and grey literature sources for studies that reported on diagnostic accuracy parameters or disease management after diagnosis. Two reviewers screened the search results, selected potentially relevant studies and extracted data. We used a bivariate mixed-effects binary regression model to estimate summary diagnostic accuracy parameters. Results: We included 59 studies involving a total of 5026 evaluable patients (mostly patients suspected of having obstructive sleep apnea). Of these, 19 studies were included in the meta-analysis. The estimated area under the receiver operating characteristics curve was high, ranging between 0.85 and 0.99 across different levels of disease severity. Summary sensitivity ranged between 0.79 and 0.97, and summary specificity ranged between 0.60 and 0.93 across different apnea–hypopnea cut-offs. We saw no significant difference in the clinical management parameters between patients who underwent either test to receive their diagnosis. Interpretation: Level 3 portable devices showed good diagnostic performance compared with level 1 sleep tests in adult patients with a high pretest probability of moderate to severe obstructive sleep apnea and no unstable comorbidities. For patients suspected of having other types of sleep-disordered breathing or sleep disorders not related to breathing, level 1 testing remains the reference standard. PMID:24218531

  10. Clinical research on liver reserve function by 13C-phenylalanine breath test in aged patients with chronic liver diseases

    PubMed Central

    2010-01-01

    Background The objective of this study was to investigate whether the 13C-phenylalanine breath test could be useful for the evaluation of hepatic function in elderly volunteers and patients with chronic hepatitis B and liver cirrhosis. Methods L-[1-13C] phenylalanine was administered orally at a dose of 100 mg to 55 elderly patients with liver cirrhosis, 30 patients with chronic hepatitis B and 38 elderly healthy subjects. The breath test was performed at 8 different time points (0, 10, 20, 30, 45, 60, 90, 120 min) to obtain the values of Delta over baseline, percentage 13CO2 exhalation rate and cumulative excretion (Cum). The relationships of the cumulative excretion with the 13C-%dose/h and blood biochemical parameters were investigated. Results The 13C-%dose/h at 20 min and 30 min combined with the cumulative excretion at 60 min and 120 min correlated with hepatic function tests, serum albumin, hemoglobin, platelet and Child-Pugh score. Prothrombin time, total and direct bilirubin were significantly increased, while serum albumin, hemoglobin and platelet, the cumulative excretion at 60 min and 120 min values decreased by degrees of intensity of the disease in Child-Pugh A, B, and C patients (P < 0.01). Conclusions The 13C-phenylalanine breath test can be used as a non-invasive assay to evaluate hepatic function in elderly patients with liver cirrhosis. The 13C-%dose/h at 20 min, at 30 min and cumulative excretion at 60 min may be the key value for determination at a single time-point. 13C-phenylalanine breath test is safe and helpful in distinguishing different stages of hepatic dysfunction for elderly cirrhosis patients. PMID:20459849

  11. Properties of Urea-Doped Ice in the CRREL Test Basin,

    DTIC Science & Technology

    1983-03-01

    thickness versus initial ice thickness at start of warm-up ................ 7 9. Thin sections of urea-doped ice...following section ) on the mechanical properties of the tank, essential for achieving an ice sheet of uni- the model ice was investigated. In particular...Figure 1. elastic foundation: Measurements ~i 7 A 1 f 2 Temperature As mentioned in the preceding section , water and temperature was measured with a 1/50

  12. Comparative Analysis between Ecotoxicity of Nitrogen-, Phosphorus-, and Potassium-Based Fertilizers and Their Active Ingredients

    PubMed Central

    Simplício, Nathan de Castro Soares; Muniz, Daphne Heloísa de Freitas; Rocha, Fernanda Regina Moreira; Martins, Denis Cavalcanti; Dias, Zélia Malena Barreira; Farias, Bruno Pereira da Costa; Oliveira-Filho, Eduardo Cyrino

    2016-01-01

    This study aimed to analyze the ecotoxicity of nitrogen-, phosphorus-, and potassium-based compounds to organisms of two different trophic levels in order to compare the toxic effect between high-purity substances and these substances as components of fertilizers. Dilutions were made with the fertilizers’ potassium chloride, potassium nitrate, superphosphate, urea, and their equivalent reagents, to conduct assays to establish the acute lethal concentration for half of the population (LC50). Ten individuals of the benthic snail Biomphalaria glabrata and the fish Danio rerio were exposed to each concentration of tested compounds. As a result, the toxicity levels of potassium chloride, potassium nitrate, and urea were obtained for B. glabrata and D. rerio, with the fish being more susceptible to potassium chloride in the fertilizer and the snail to potassium nitrate and urea, in both commercial and reagent forms. Regarding superphosphate, no significant toxicity was found. This study concluded that among the tested substances, KNO3 and KCl were the most toxic substances and urea the least toxic. It was not possible to establish the most sensitive species since, for KCl, the fish were more susceptible to the fertilizer and the snail to the reagent, while for KNO3 the opposite was observed. PMID:29051434

  13. A probability-based multi-cycle sorting method for 4D-MRI: A simulation study

    PubMed Central

    Liang, Xiao; Yin, Fang-Fang; Liu, Yilin; Cai, Jing

    2016-01-01

    Purpose: To develop a novel probability-based sorting method capable of generating multiple breathing cycles of 4D-MRI images and to evaluate performance of this new method by comparing with conventional phase-based methods in terms of image quality and tumor motion measurement. Methods: Based on previous findings that breathing motion probability density function (PDF) of a single breathing cycle is dramatically different from true stabilized PDF that resulted from many breathing cycles, it is expected that a probability-based sorting method capable of generating multiple breathing cycles of 4D images may capture breathing variation information missing from conventional single-cycle sorting methods. The overall idea is to identify a few main breathing cycles (and their corresponding weightings) that can best represent the main breathing patterns of the patient and then reconstruct a set of 4D images for each of the identified main breathing cycles. This method is implemented in three steps: (1) The breathing signal is decomposed into individual breathing cycles, characterized by amplitude, and period; (2) individual breathing cycles are grouped based on amplitude and period to determine the main breathing cycles. If a group contains more than 10% of all breathing cycles in a breathing signal, it is determined as a main breathing pattern group and is represented by the average of individual breathing cycles in the group; (3) for each main breathing cycle, a set of 4D images is reconstructed using a result-driven sorting method adapted from our previous study. The probability-based sorting method was first tested on 26 patients’ breathing signals to evaluate its feasibility of improving target motion PDF. The new method was subsequently tested for a sequential image acquisition scheme on the 4D digital extended cardiac torso (XCAT) phantom. Performance of the probability-based and conventional sorting methods was evaluated in terms of target volume precision and accuracy as measured by the 4D images, and also the accuracy of average intensity projection (AIP) of 4D images. Results: Probability-based sorting showed improved similarity of breathing motion PDF from 4D images to reference PDF compared to single cycle sorting, indicated by the significant increase in Dice similarity coefficient (DSC) (probability-based sorting, DSC = 0.89 ± 0.03, and single cycle sorting, DSC = 0.83 ± 0.05, p-value <0.001). Based on the simulation study on XCAT, the probability-based method outperforms the conventional phase-based methods in qualitative evaluation on motion artifacts and quantitative evaluation on tumor volume precision and accuracy and accuracy of AIP of the 4D images. Conclusions: In this paper the authors demonstrated the feasibility of a novel probability-based multicycle 4D image sorting method. The authors’ preliminary results showed that the new method can improve the accuracy of tumor motion PDF and the AIP of 4D images, presenting potential advantages over the conventional phase-based sorting method for radiation therapy motion management. PMID:27908178

  14. Time course of the acute response of the North Pacific spiny dogfish shark (Squalus suckleyi) to low salinity.

    PubMed

    Guffey, Samuel C; Goss, Greg G

    2014-05-01

    Dogfish are considered stenohaline sharks but are known to briefly enter estuaries. The acute response of North Pacific spiny dogfish (Squalus suckleyi) to lowered salinity was tested by exposing sharks to 21‰ salinity for 48 h. Temporal trends in blood pH, plasma osmolality, CO2, HCO3(-), Na(+), Cl(-), K(+), and urea concentrations, and in the rates of urea efflux and O2 consumption, were quantified. The rate of O2 consumption exhibited cyclic variation and was significantly depressed by lowered salinity. After 9 h, plasma [Cl(-)] stabilized at 9% below initial levels, while plasma [Na(+)] decreased by more than 20% within the first 12 h. Plasma [urea] dropped by 15% between 4 and 6 h, and continued to decrease. The rate of urea efflux increased over time, peaking after 36 h at 72% above the initial rate. Free-swimming sharks subjected to the same salinity challenge survived over 96 h and differed from cannulated sharks with respect to patterns of Na(+) and urea homeostasis. This high-resolution study reveals that dogfish exposed to 21‰ salinity can maintain homeostasis of Cl(-) and pH, but Na(+) and urea continue to be lost, likely accounting for the inability of the dogfish to fully acclimate to reduced salinity. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Comparison of an increased waist circumference with a positive hydrogen breath test as a clinical predictor of lactose intolerance.

    PubMed

    Zapata-Castilleja, Carlos A; Montes-Tapia, Fernando F; Treviño-Garza, Consuelo; Martínez-Cobos, María C; García-Cantú, Jesús; Arenas-Fabbri, Vincenzo; de la O-Escamilla, Norma; de la O-Cavazos, Manuel

    2017-04-01

    Lactose intolerance is a common disease in pediatrics, and its wrong diagnosis will lead to morbidity. The primary objective of this study was to assess the usefulness of an increased waist circumference during the hydrogen breath test as a predictor of lactose intolerance. The secondary objective was to analyze the impact of body mass index, waist circumference measurement, and age on the abdominal distension of patients with lactose intolerance. A total of 138 subjects aged 3 to 15 years were included. They underwent serial measurements of the waist circumference and hydrogen levels in the breath every 30 minutes over 3 hours during the hydrogen breath test. Out of the entire sample, 35 (25.4%) patients had lactose intolerance. An increase of 0.85 cm in waist circumference compared to the baseline waist circumference results in a sensitivity of 88% and a specificity of 85% to predict lactose intolerance (odds ratio: 42.14, 95% confidence interval: 13.08-135.75, p ≤ 0.001). The body mass index and waist circumference measurement did not affect abdominal distension (p= not significant); however, age modified the time of distension. A 0.85 cm increase in waist circumference compared to the baseline waist circumference during the hydrogen breath test is a useful parameter for the diagnosis of lactose intolerance in pediatrics. Variations in relation to body mass index and waist circumference did not affect the usefulness of an increased waist circumference, unlike age.

  16. Pathogen variation and urea influence selection and success of Streptomyces mixtures in biological control.

    PubMed

    Otto-Hanson, L K; Grabau, Z; Rosen, C; Salomon, C E; Kinkel, L L

    2013-01-01

    Success in biological control of plant diseases remains inconsistent in the field. A collection of well-characterized Streptomyces antagonists (n = 19 isolates) was tested for their capacities to inhibit pathogenic Streptomyces scabies (n = 15 isolates). There was significant variation among antagonists in ability to inhibit pathogen isolates and among pathogens in their susceptibility to inhibition. Only one antagonist could inhibit all pathogens, and antagonist-pathogen interactions were highly specific, highlighting the limitations of single-strain inoculum in biological control. However, the collection of pathogens could be inhibited by several combinations of antagonists, suggesting the potential for successful antagonist mixtures. Urea generally increased effectiveness of antagonists at inhibiting pathogens in vitro (increased mean inhibition zones) but its specific effects varied among antagonist-pathogen combinations. In greenhouse trials, urea enhanced the effectiveness of antagonist mixtures relative to individual antagonists in controlling potato scab. Although antagonist mixtures were frequently antagonistic in the absence of urea, all n= 2 and n = 3 antagonist-isolate combinations were synergistic in the presence of urea. This work provides insights into the efficacy of single- versus multiple-strain inocula in biological control and on the potential for nutrients to influence mixture success.

  17. Spike-Timing of Orbitofrontal Neurons Is Synchronized With Breathing.

    PubMed

    Kőszeghy, Áron; Lasztóczi, Bálint; Forro, Thomas; Klausberger, Thomas

    2018-01-01

    The orbitofrontal cortex (OFC) has been implicated in a multiplicity of complex brain functions, including representations of expected outcome properties, post-decision confidence, momentary food-reward values, complex flavors and odors. As breathing rhythm has an influence on odor processing at primary olfactory areas, we tested the hypothesis that it may also influence neuronal activity in the OFC, a prefrontal area involved also in higher order processing of odors. We recorded spike timing of orbitofrontal neurons as well as local field potentials (LFPs) in awake, head-fixed mice, together with the breathing rhythm. We observed that a large majority of orbitofrontal neurons showed robust phase-coupling to breathing during immobility and running. The phase coupling of action potentials to breathing was significantly stronger in orbitofrontal neurons compared to cells in the medial prefrontal cortex. The characteristic synchronization of orbitofrontal neurons with breathing might provide a temporal framework for multi-variable processing of olfactory, gustatory and reward-value relationships.

  18. Can salivary creatinine and urea levels be used to diagnose chronic kidney disease in children as accurately as serum creatinine and urea levels? A case-control study.

    PubMed

    Renda, Rahime

    2017-11-01

    Children with chronic kidney disease (CKD) develop many metabolic changes in blood that often necessitate frequent biochemical analysis. Serum analysis is an invasive and painful procedure. It would be highly beneficial if a noninvasive alternative process to serum analysis in children were identified. Saliva can be collected noninvasively, repeatedly, and without the use of healthcare personnel. The aims of this study were to compare serum and salivary urea and creatinine levels in children with CKD and healthy controls, and to determine if salivary creatinine and urea levels can be used to diagnose CKD in children as accurately as serum creatinine and urea levels. This case-control study included 35 children with CKD and 28 healthy children as controls. Saliva and blood samples were collected for measurement of urea and creatinine levels. The urea and creatinine levels in serum and saliva in the CKD and control groups were compared using the independent samples Mann-Whitney U test. Correlations between the serum and salivary urea and creatinine levels were determined using Pearson's correlation coefficient. Receiver operating characteristic analysis was used to assess the diagnostic performance of salivary creatinine and cutoff values were identified. In the CKD group, the mean salivary creatinine level was 0.45 mg/dL and the mean salivary urea level was 0.11 mg/dL, versus 28.83 mg/dL and 21.78 mg/dL, respectively, in the control group. Stage 4 and 5 CKD patients had a mean salivary urea level of 31.35 mg/dL, as compared to 17.78 mg/dL in the control group. Serum urea and creatinine, and salivary creatinine were significantly higher in the CKD patients (regardless of disease stage) than in the controls (p < .05). The salivary urea level was significantly higher in the stage 4 and 5 CKD patients than in the controls (p < .05). There was a positive correlation between serum and salivary creatinine. The area under the curve for salivary creatinine was 0.805. The cutoff value for salivary creatinine was 0.125 mg/dL, with a sensitivity of 82.9% and specificity of 78.6%. Based on the positive correlation between the serum and saliva creatinine levels observed in the present study, we think saliva analysis could be used as a noninvasive alternative to blood analysis for diagnosing CKD in children.

  19. Study of ethane level in exhaled breath in patients with age-related macular degeneration: preliminary study.

    PubMed

    Cagini, C; Giordanelli, A; Fiore, T; Giardinieri, R; Malici, B; De Medio, G E; Pelli, M A; De Bellis, F; Capodicasa, E

    2011-01-01

    A variety of factors have been implicated in the pathogenesis of age-related macular degeneration (ARMD), and oxidative stress plays an important role in the onset and progression of the disease. Breath ethane is now considered a specific and non-invasive test for determining and monitoring the trend of lipid peroxidation and free radical-induced damage in vivo. This test provides an index of the patients' overall oxidative stress level. We evaluated the breath ethane concentration in exhaled air in patients with advanced ARMD. In this study, we enrolled 13 patients with advanced ARMD and a control group, and a breath analysis was carried out by gas chromatography. The mean ethane level in the ARMD patients was 0.82 ± 0.93 nmol/l (range: 0.01-2.7 nmol/l) and the mean ethane value in the control group was 0.12 ± 0.02 nmol/l (range: 0.08-0.16 nmol/l). The difference between the values of the 2 groups was statistically significant (p < 0.005). Receiver operating characteristic analysis showed an elevated area under the curve (0.831; 95% CI: 0.634-0.948), with a significance level of p < 0.0014 (area = 0.5). These preliminary results seem to indicate that breath ethane levels are higher in most patients with ARMD. The breath ethane test could thus be a useful method for evaluating the level of oxidative stress in patients with ARMD. To our knowledge, there are no data on this type of analysis applied to ARMD. Copyright © 2011 S. Karger AG, Basel.

  20. The prevalence of Helicobacter pylori gastritis in newly diagnosed children with inflammatory bowel disease.

    PubMed

    Roka, Kleoniki; Roubani, Aikaterini; Stefanaki, Kalliopi; Panayotou, Ioanna; Roma, Eleftheria; Chouliaras, Giorgos

    2014-10-01

    Recent studies have shown that patients with inflammatory bowel disease (IBD) are less likely to be infected with Helicobacter pylori compared with non-IBD patients. We aimed to study the prevalence of H. pylori-positive and H. pylori-negative gastritis in newly diagnosed children with IBD in comparison to those with non-IBD in Greece. All children who underwent first esophagogastroduodenal endoscopy between 2002 and 2011 were retrospectively included. Four groups were studied: patients with Crohn's disease (CD), ulcerative colitis (UC), IBD unclassified (IBDU), and non-IBD individuals (non-IBD). Helicobacter pylori infection was defined by positive culture or by positive histology and CLO test. Those children with negative or not available culture and only one positive test (histology or CLO) were further evaluated by urea breath test, and the positives were also included in the infected group. We studied 159 patients with IBD (66 CD, 34 UC, and 59 IBDU) and 1209 patients in non-IBD individuals. Helicobacter pylori gastritis was less frequent in the IBD group (3.8% vs 13.2% in the control group, p < .001), whereas IBD patients were significantly older than non-IBD children (p < .001). Children with H. pylori-negative gastritis were 3.3 times more likely to belong in the IBD group compared with H. pylori-positive patients (p = .006). Occurrence of H. pylori gastritis is less frequent in children with IBD compared with controls. Our study confirms an inverse association between H. pylori and IBD. Future studies are needed to distinguish between a true protective role of H. pylori and a confounding effect due to previous antibiotic use in children with IBD. © 2014 John Wiley & Sons Ltd.

  1. Helicobacter pylori eradication with lansoprazole, amoxycillin and clarithromycin: testing an ideal regimen in a multicultural south east Asian population and examining factors potentially influencing eradication.

    PubMed

    Kaushik, S P; Vu, C

    2000-04-01

    From European and North American data, it is recommended in the Asia Pacific consensus statement, that one week therapy with a proton pump inhibitor, amoxycillin and clarithromycin be used for Helicobacter pylori eradication, in areas of high metronidazole resistance. The efficacy of this regimen is unknown in Singapore. To assess the efficacy, safety and compliance of an H. pylori eradication regimen and examine clinical factors that potentially determine eradication. Consecutive outpatients from a multicultural, south east Asian, population with H. pylori infection, with or without peptic ulcer, were treated with lansoprazole 30 mg, amoxycillin 1 gm, clarithromycin 500 mg, twice a day for seven days. Eradication was assessed by either rapid urease, histology or urea breath test. Compliance and side effects were recorded. The eradication rate and effect of ethnicity, age, sex, usage of alcohol, smoking and non-steroidal anti-inflammatory drugs, history of ulcer and endoscopic diagnosis on eradication were examined by univariate and multivariate analysis. Of 113 patients, the eradication rate by intention to treat was 98/113 (87%) (95% confidence interval [CI] 80-93%) and per protocol was 98/106 (92%) (95% CI 87-97%). Using Fisher's exact test, eradication was more successful in Chinese (intention to treat and per protocol respectively p=0.02 and p<0.001) compared to non-Chinese. By logistic regression analysis ethnicity was an independent factor associated with eradication success (p=0.0025). Side effects occurred in five (4.4%), resulting in cessation of treatment. This one week eradication regimen is safe and effective in south east Asians. Chinese ethnicity may be associated with a higher likelihood of eradication success.

  2. Illustrating economic evaluation of diagnostic technologies: comparing Helicobacter pylori screening strategies in prevention of gastric cancer in Canada.

    PubMed

    Xie, Feng; O'Reilly, Daria; Ferrusi, Ilia L; Blackhouse, Gord; Bowen, James M; Tarride, Jean-Eric; Goeree, Ron

    2009-05-01

    The aim of this paper is to present an economic evaluation of diagnostic technologies using Helicobacter pylori screening strategies for the prevention of gastric cancer as an illustration. A Markov model was constructed to compare the lifetime cost and effectiveness of 4 potential strategies: no screening, the serology test by enzyme-linked immunosorbent assay (ELISA), the stool antigen test (SAT), and the (13)C-urea breath test (UBT) for the detection of H. pylori among a hypothetical cohort of 10,000 Canadian men aged 35 years. Special parameter consideration included the sensitivity and specificity of each screening strategy, which determined the model structure and treatment regimen. The primary outcome measured was the incremental cost-effectiveness ratio between the screening strategies and the no-screening strategy. Base-case analysis and probabilistic sensitivity analysis were performed using the point estimates of the parameters and Monte Carlo simulations, respectively. Compared with the no-screening strategy in the base-case analysis, the incremental cost-effectiveness ratio was $33,000 per quality-adjusted life-year (QALY) for the ELISA, $29,800 per QALY for the SAT, and $50,400 per QALY for the UBT. The probabilistic sensitivity analysis revealed that the no-screening strategy was more cost effective if the willingness to pay (WTP) was <$20,000 per QALY, while the SAT had the highest probability of being cost effective if the WTP was >$30,000 per QALY. Both the ELISA and the UBT were not cost-effective strategies over a wide range of WTP values. Although the UBT had the highest sensitivity and specificity, either no screening or the SAT could be the most cost-effective strategy depending on the WTP threshold values from an economic perspective. This highlights the importance of economic evaluations of diagnostic technologies.

  3. Rare Helicobacter pylori Infection May Explain Low Stomach Cancer Incidence: Ecological Observations in Bali, Indonesia.

    PubMed

    Tanaka, Tsutomu; Mulyadi, I Ketut; Moestikaningsih; Oka, Tjok Gede; Soeripto; Triningsih, Fx Ediati; Triyono, Teguh; Heriyanto, Didik Setyo; Hosono, Akihiro; Suzuki, Sadao; Tokudome, Shinkan

    2016-01-01

    The incidence rate of stomach cancer in Bali, Indonesia, is estimated to be strikingly lower than that in Japan. We conducted an on-site ecological study to investigate the association between the stomach cancer incidence and Helicobacter pylori (H. pylori) infection. Recruiting 291 healthy persons (136 men and 155 women) from the general population in Bali, Indonesia, we conducted a urea breath test (UBT) to examine H. pylori infection, along with a pepsinogen test to detect chronic atrophic gastritis and urine analysis to estimate sodium and potassium excretion. UBT positivities were 9% (2-15, 95% confidence interval) for men and 7% (1-12) for women, and positive cases for H. pylori IgG antibodies were 1% (0-3) for men and 3% (0-5) for women, significantly lower than the respective values in Japan. Positive pepsinogen tests in Bali were 0% (0-0) for men and 1% (0-4) for women, also significantly lower than the Japanese figures. Computed values for daily salt excretion were 13.3±4.1 g (mean ± SD) for men and 11.1±3.1 g for women, as high as corresponding Japanese consumption values. Moreover, the estimated potassium excretion was 3.2±0.7 g for men and 2.8±0.6 g for women in Bali, significantly higher than the figures in Japan. There were no associations across genetic polymorphisms of IL-beta, TNF-alpha, and PTPN11 with UBT positivity. The low incidence of stomach cancer in Bali may thus mainly be due to the rare H. pylori infection. Namely, the bacterium infection seems to be a critical factor for gastric cancer rather than host or other environmental factors.

  4. Current concepts in the management of Helicobacter pylori infection: the Maastricht III Consensus Report

    PubMed Central

    Malfertheiner, P; Megraud, F; O'Morain, C; Bazzoli, F; El‐Omar, E; Graham, D; Hunt, R; Rokkas, T; Vakil, N; Kuipers, E J

    2007-01-01

    Background Guidelines on the management of Helicobacter pylori, which cover indications for management and treatment strategies, were produced in 2000. Aims To update the guidelines at the European Helicobacter Study Group (EHSG) Third Maastricht Consensus Conference, with emphasis on the potential of H pylori eradication for the prevention of gastric cancer. Results Eradication of H pylori infection is recommended in (a) patients with gastroduodenal diseases such as peptic ulcer disease and low grade gastric, mucosa associated lymphoid tissue (MALT) lymphoma; (b) patients with atrophic gastritis; (c) first degree relatives of patients with gastric cancer; (d) patients with unexplained iron deficiency anaemia; and (e) patients with chronic idiopathic thrombocytopenic purpura. Recurrent abdominal pain in children is not an indication for a “test and treat” strategy if other causes are excluded. Eradication of H pylori infection (a) does not cause gastro‐oesophageal reflux disease (GORD) or exacerbate GORD, and (b) may prevent peptic ulcer in patients who are naïve users of non‐steroidal anti‐inflammatory drugs (NSAIDs). H pylori eradication is less effective than proton pump inhibitor (PPI) treatment in preventing ulcer recurrence in long term NSAID users. In primary care a test and treat strategy using a non‐invasive test is recommended in adult patients with persistent dyspepsia under the age of 45. The urea breath test, stool antigen tests, and serological kits with a high accuracy are non‐invasive tests which should be used for the diagnosis of H pylori infection. Triple therapy using a PPI with clarithromycin and amoxicillin or metronidazole given twice daily remains the recommended first choice treatment. Bismuth‐containing quadruple therapy, if available, is also a first choice treatment option. Rescue treatment should be based on antimicrobial susceptibility. Conclusion The global burden of gastric cancer is considerable but varies geographically. Eradication of H pylori infection has the potential to reduce the risk of gastric cancer development. PMID:17170018

  5. Responses of Ammonia-Oxidizing Bacterial and Archaeal Populations to Organic Nitrogen Amendments in Low-Nutrient Groundwater ▿

    PubMed Central

    Reed, David W.; Smith, Jason M.; Francis, Christopher A.; Fujita, Yoshiko

    2010-01-01

    To evaluate the potential for organic nitrogen addition to stimulate the in situ growth of ammonia oxidizers during a field scale bioremediation trial, samples collected from the Eastern Snake River Plain Aquifer in Idaho before, during, and after the addition of molasses and urea were subjected to PCR analysis of ammonia monooxygenase subunit A (amoA) genes. Ammonia-oxidizing bacteria (AOB) and archaea (AOA) were present in all of the samples tested, with AOA amoA genes outnumbering AOB amoA genes in all of the samples. Following urea addition, nitrate levels rose and bacterial amoA copy numbers increased dramatically, suggesting that urea hydrolysis stimulated nitrification. Bacterial amoA diversity was limited to two Nitrosomonas phylotypes, whereas archaeal amoA analyses revealed 20 distinct operational taxonomic units, including several that were markedly different from all previously reported sequences. Results from this study demonstrate the likelihood of stimulating ammonia-oxidizing communities during field scale manipulation of groundwater conditions to promote urea hydrolysis. PMID:20190081

  6. In vitro studies on the effect of physical cross-linking on the biological performance of aliphatic poly(urethane urea) for blood contact applications.

    PubMed

    Thomas, V; Kumari, T V; Jayabalan, M

    2001-01-01

    The effect of physical cross-linking in candidate cycloaliphatic and hydrophobic poly(urethane urea) (4,4'-methylenebis(cyclohexylisocyanate), H(12)MDI/hydroxy-terminated polybutadiene, HTPBD/hexamethylenediamine, HDA) and poly(ether urethane urea)s (H(12)MDI/HTPBD-PTMG/HDA) on the in vitro calcification and blood-material interaction was studied. All the candidate poly(urethane urea)s and poly(ether urethane urea)s elicit acceptable hemolytic activity, cytocompatibility, calcification, and blood compatibility in vitro. The studies on blood-material interaction reveal that the present poly(urethane urea)s are superior to polystyrene microtiter plates which were used for the studies on blood-material interaction. The present investigation reveals the influence of physical cross-link density on biological interaction differently with poly(urethane urea) and poly(ether urethane urea)s. The higher the physical cross-link density in the poly(urethane urea)s, the higher the calcification and consumption of WBC in whole blood. On the other hand, the higher the physical cross-link density in the poly(ether urethane urea)s, the lesser the calcification and consumption of WBC in whole blood. However a reverse of the above trend has been observed with the platelet consumption in the poly(urethane urea)s and poly(ether urethane urea)s.

  7. Breath acidification in adolescent runners exposed to atmospheric pollution: A prospective, repeated measures observational study

    PubMed Central

    Ferdinands, Jill M; Crawford, Carol A Gotway; Greenwald, Roby; Van Sickle, David; Hunter, Eric; Teague, W Gerald

    2008-01-01

    Background Vigorous outdoors exercise during an episode of air pollution might cause airway inflammation. The purpose of this study was to examine the effects of vigorous outdoor exercise during peak smog season on breath pH, a biomarker of airway inflammation, in adolescent athletes. Methods We measured breath pH both pre- and post-exercise on ten days during peak smog season in 16 high school athletes engaged in daily long-distance running in a downwind suburb of Atlanta. The association of post-exercise breath pH with ambient ozone and particulate matter concentrations was tested with linear regression. Results We collected 144 pre-exercise and 146 post-exercise breath samples from 16 runners (mean age 14.9 years, 56% male). Median pre-exercise breath pH was 7.58 (interquartile range: 6.90 to 7.86) and did not change significantly after exercise. We observed no significant association between ambient ozone or particulate matter and post-exercise breath pH. However both pre- and post-exercise breath pH were strikingly low in these athletes when compared to a control sample of 14 relatively sedentary healthy adults and to published values of breath pH in healthy subjects. Conclusion Although we did not observe an acute effect of air pollution exposure during exercise on breath pH, breath pH was surprisingly low in this sample of otherwise healthy long-distance runners. We speculate that repetitive vigorous exercise may induce airway acidification. PMID:18328105

  8. The importance of a normal breathing pattern for an effective abdominal-hollowing maneuver in healthy people: an experimental study.

    PubMed

    Ha, Sung-min; Kwon, Oh-yun; Kim, Su-jung; Choung, Sung-dae

    2014-02-01

    A normal breathing pattern while performing the abdominal-hollowing (AH) maneuver or spinal-stabilization exercise is essential for the success of rehabilitation programs and exercises. In previous studies, subjects were given standardized instructions to control the influence of respiration during the AH maneuver. However, the effect of breathing pattern on abdominal-muscle thickness during the AH maneuver has not been investigated. To compare abdominal-muscle thickness in subjects performing the AH maneuver under normal and abnormal breathing-pattern conditions and to investigate the effect of breathing pattern on the preferential contraction ratio (PCR) of the transverse abdominis. Comparative, repeated-measures experimental study. University research laboratory. 16 healthy subjects (8 male, 8 female) from a university population. A real-time ultrasound scanner was used to measure abdominal-muscle thickness during normal and abnormal breathing patterns. A paired t test was used to assess the effect of breathing pattern on abdominal-muscle thickness and PCR. Muscle thickness in the transverse abdominis and internal oblique muscles was significantly greater under the normal breathing pattern than under the abnormal pattern (P < .05). The PCR of the transverse abdominis was significantly higher under the normal breathing pattern compared with the abnormal pattern (P < .05). The results indicate that a normal breathing pattern is essential for performance of an effective AH maneuver. Thus, clinicians should ensure that patients adopt a normal breathing pattern before performing the AH maneuver and monitor transverse abdominis activation during the maneuver.

  9. A fully integrated standalone portable cavity ringdown breath acetone analyzer.

    PubMed

    Sun, Meixiu; Jiang, Chenyu; Gong, Zhiyong; Zhao, Xiaomeng; Chen, Zhuying; Wang, Zhennan; Kang, Meiling; Li, Yingxin; Wang, Chuji

    2015-09-01

    Breath analysis is a promising new technique for nonintrusive disease diagnosis and metabolic status monitoring. One challenging issue in using a breath biomarker for potential particular disease screening is to find a quantitative relationship between the concentration of the breath biomarker and clinical diagnostic parameters of the specific disease. In order to address this issue, we need a new instrument that is capable of conducting real-time, online breath analysis with high data throughput, so that a large scale of clinical test (more subjects) can be achieved in a short period of time. In this work, we report a fully integrated, standalone, portable analyzer based on the cavity ringdown spectroscopy technique for near-real time, online breath acetone measurements. The performance of the portable analyzer in measurements of breath acetone was interrogated and validated by using the certificated gas chromatography-mass spectrometry. The results show that this new analyzer is useful for reliable online (online introduction of a breath sample without pre-treatment) breath acetone analysis with high sensitivity (57 ppb) and high data throughput (one data per second). Subsequently, the validated breath analyzer was employed for acetone measurements in 119 human subjects under various situations. The instrument design, packaging, specifications, and future improvements were also described. From an optical ringdown cavity operated by the lab-set electronics reported previously to this fully integrated standalone new instrument, we have enabled a new scientific tool suited for large scales of breath acetone analysis and created an instrument platform that can even be adopted for study of other breath biomarkers by using different lasers and ringdown mirrors covering corresponding spectral fingerprints.

  10. A fully integrated standalone portable cavity ringdown breath acetone analyzer

    NASA Astrophysics Data System (ADS)

    Sun, Meixiu; Jiang, Chenyu; Gong, Zhiyong; Zhao, Xiaomeng; Chen, Zhuying; Wang, Zhennan; Kang, Meiling; Li, Yingxin; Wang, Chuji

    2015-09-01

    Breath analysis is a promising new technique for nonintrusive disease diagnosis and metabolic status monitoring. One challenging issue in using a breath biomarker for potential particular disease screening is to find a quantitative relationship between the concentration of the breath biomarker and clinical diagnostic parameters of the specific disease. In order to address this issue, we need a new instrument that is capable of conducting real-time, online breath analysis with high data throughput, so that a large scale of clinical test (more subjects) can be achieved in a short period of time. In this work, we report a fully integrated, standalone, portable analyzer based on the cavity ringdown spectroscopy technique for near-real time, online breath acetone measurements. The performance of the portable analyzer in measurements of breath acetone was interrogated and validated by using the certificated gas chromatography-mass spectrometry. The results show that this new analyzer is useful for reliable online (online introduction of a breath sample without pre-treatment) breath acetone analysis with high sensitivity (57 ppb) and high data throughput (one data per second). Subsequently, the validated breath analyzer was employed for acetone measurements in 119 human subjects under various situations. The instrument design, packaging, specifications, and future improvements were also described. From an optical ringdown cavity operated by the lab-set electronics reported previously to this fully integrated standalone new instrument, we have enabled a new scientific tool suited for large scales of breath acetone analysis and created an instrument platform that can even be adopted for study of other breath biomarkers by using different lasers and ringdown mirrors covering corresponding spectral fingerprints.

  11. Exhaled breath temperature in children: reproducibility and influencing factors.

    PubMed

    Vermeulen, S; Barreto, M; La Penna, F; Prete, A; Martella, S; Biagiarelli, F; Villa, M P

    2014-09-01

    This study will investigate the reproducibility and influencing factors of exhaled breath temperature measured with the tidal breathing technique in asthmatic patients and healthy children. Exhaled breath temperature, fractional exhaled nitric oxide, and spirometry were assessed in 124 children (63 healthy and 61 asthmatic), aged 11.2 ± 2.5 year, M/F 73/51. A modified version of the American Thoracic Society questionnaire on the child's present and past respiratory history was obtained from parents. Parents were also asked to provide detailed information on their child's medication use during the previous 4 weeks. Ear temperature, ambient temperature, and relative-ambient humidity were also recorded. Exhaled breath temperature measurements were highly reproducible; the second measurement was higher than the first measurement, consistent with a test-retest situation. In 13 subjects, between-session within-day reproducibility of exhaled breath temperature was still high. Exhaled breath temperature increased with age and relative-ambient humidity. Exhaled breath temperature was comparable in healthy and asthmatic children; when adjusted for potential confounders (i.e. ambient conditions and subject characteristics), thermal values of asthmatic patients exceeded those of the healthy children by 1.1 °C. Normalized exhaled breath temperature, by subtracting ambient temperature, was lower in asthmatic patients treated with inhaled corticosteroids than in those who were corticosteroid-naive. Measurements of exhaled breath temperature are highly reproducible, yet influenced by several factors. Corrected values, i.e. normalized exhaled breath temperature, could help us to assess the effect of therapy with inhaled corticosteroids. More studies are needed to improve the usefulness of the exhaled breath temperature measured with the tidal breathing technique in children.

  12. A simple apparatus for measuring the blood urea, manufactured by Dr. Luigj Benusi in 1943 in Albania.

    PubMed

    Tartari, Flamur; Buzo, Stiliano; Vyshka, Gentian

    2009-01-01

    The apparatus invented by Dr. Luigj Benusi in 1943, in Tirana, was a practical application of the Kowarsky technique and Ambard laws, helping in determining blood urea levels and very important to a variety of diseases, mainly kidney disorders. The apparatus was invented and prepared from very simple laboratory materials, such as glasses, test tubes, corks and volumetric cylinders. Technologically, it was based upon the determination of blood urea through hypobromite, and, among the advantages of the apparatus of Benusi, were its extreme simplicity, the smaller amount of blood needed for producing results (2 milliliters), as well as an easiest way to clean up and to manage the apparatus from a practical point of everyday use.

  13. Impact of orocecal transit time on patient´s perception of lactose intolerance.

    PubMed

    Casellas, Francesc; Aparici, Anna; Casaus, Maite; Rodríguez, Purificación; Malagelada, Juan R

    2013-01-01

    symptoms attributed to the lactose intolerance are an important public health issue because of their prevalence and social relevance. Also because they may cause undue rejection of dairy products consume with potential health consequences. Transit time is a putative factor implied in the severity of symptoms associated with lactose. to elucidate the relation between orocecal transit time (OCTT) and lactose intolerance symptoms. observational study in patients referred to a lactose hydrogen breath test who showed an increase in breath H2 excretion higher than 25 ppm. OCTT was measured with the breath test and symptoms of lactose tolerance with a validated scale. Symptoms were measured twice: before receiving the lactose, inquiring about self perceived symptoms when patients consumed dairy products at home ("home symptoms"), and again after completing the lactose breath test ("test symptoms"). 161 patients were included. There was no correlation between OCTT and home symptoms (r = -0.1). When OCTT was faster than 60 minutes, intensity of "test symptoms" was similar to "home symptoms". However, in patients with normal or slow OCTT, the "home symptoms" were more intense than the "test symptoms" (p < 0.05). At home, symptoms were independent of OCTT but with the lactose test load the symptoms were proportionately more intense with faster OCTT. in lactose maldigesters, selfreported symptoms of lactose intolerance are more pronounced at home than after a high lactose challenge. Intolerance symptoms that patients attributed to lactose consume at home are due to factors other than fast OCTT.

  14. Comparison of the analytical capabilities of the BAC Datamaster and Datamaster DMT forensic breath testing devices.

    PubMed

    Glinn, Michele; Adatsi, Felix; Curtis, Perry

    2011-11-01

    The State of Michigan uses the Datamaster as an evidential breath testing device. The newest version, the DMT, will replace current instruments in the field as they are retired from service. The Michigan State Police conducted comparison studies to test the analytical properties of the new instrument and to evaluate its response to conditions commonly cited in court defenses. The effects of mouth alcohol, objects in the mouth, and radiofrequency interference on paired samples from drinking subjects were assessed on the DMT. The effects of sample duration and chemical interferents were assessed on both instruments, using drinking subjects and wet-bath simulators, respectively. Our testing shows that Datamaster and DMT results are essentially identical; the DMT gave accurate readings as compared with measurements made using simulators containing standard ethanol solutions and that the DMT did not give falsely elevated breath alcohol results from any of the influences tested. © 2011 American Academy of Forensic Sciences.

  15. Laboratory evaluation of two passive alcohol sensor devices

    DOT National Transportation Integrated Search

    1988-12-01

    Passive alcohol sensing devices are designed to detect the presence of alcohol in a person's normally-expelled breath; they are "passive" in that one is not required to blow into a mouthpiece as with conventional breath test devices. The National Hig...

  16. Breath biomarkers in toxicology.

    PubMed

    Pleil, Joachim D

    2016-11-01

    Exhaled breath has joined blood and urine as a valuable resource for sampling and analyzing biomarkers in human media for assessing exposure, uptake metabolism, and elimination of toxic chemicals. This article focuses current use of exhaled gas, aerosols, and vapor in human breath, the methods for collection, and ultimately the use of the resulting data. Some advantages of breath are the noninvasive and self-administered nature of collection, the essentially inexhaustible supply, and that breath sampling does not produce potentially infectious waste such as needles, wipes, bandages, and glassware. In contrast to blood and urine, breath samples can be collected on demand in rapid succession and so allow toxicokinetic observations of uptake and elimination in any time frame. Furthermore, new technologies now allow capturing condensed breath vapor directly, or just the aerosol fraction alone, to gain access to inorganic species, lung pH, proteins and protein fragments, cellular DNA, and whole microorganisms from the pulmonary microbiome. Future applications are discussed, especially the use of isotopically labeled probes, non-targeted (discovery) analysis, cellular level toxicity testing, and ultimately assessing "crowd breath" of groups of people and the relation to dose of airborne and other environmental chemicals at the population level.

  17. Breath acetone monitoring by portable Si:WO3 gas sensors

    PubMed Central

    Righettoni, Marco; Tricoli, Antonio; Gass, Samuel; Schmid, Alex; Amann, Anton; Pratsinis, Sotiris E.

    2013-01-01

    Breath analysis has the potential for early stage detection and monitoring of illnesses to drastically reduce the corresponding medical diagnostic costs and improve the quality of life of patients suffering from chronic illnesses. In particular, the detection of acetone in the human breath is promising for non-invasive diagnosis and painless monitoring of diabetes (no finger pricking). Here, a portable acetone sensor consisting of flame-deposited and in situ annealed, Si-doped epsilon-WO3 nanostructured films was developed. The chamber volume was miniaturized while reaction-limited and transport-limited gas flow rates were identified and sensing temperatures were optimized resulting in a low detection limit of acetone (~20 ppb) with short response (10–15 s) and recovery times (35–70 s). Furthermore, the sensor signal (response) was robust against variations of the exhaled breath flow rate facilitating application of these sensors at realistic relative humidities (80–90%) as in the human breath. The acetone content in the breath of test persons was monitored continuously and compared to that of state-of-the-art proton transfer reaction mass spectrometry (PTR-MS). Such portable devices can accurately track breath acetone concentration to become an alternative to more elaborate breath analysis techniques. PMID:22790702

  18. Double-blind randomized controlled trial of rifaximin for persistent symptoms in patients with celiac disease.

    PubMed

    Chang, Matthew S; Minaya, Maria T; Cheng, Jianfeng; Connor, Bradley A; Lewis, Suzanne K; Green, Peter H R

    2011-10-01

    Small intestinal bacterial overgrowth (SIBO) is one cause of a poor response to a gluten-free diet (GFD) and persistent symptoms in celiac disease. Rifaximin has been reported to improve symptoms in non-controlled trials. To determine the effect of rifaximin on gastrointestinal symptoms and lactulose-hydrogen breath tests in patients with poorly responsive celiac disease. A single-center, double-blind, randomized, controlled trial of patients with biopsy-proven celiac disease and persistent gastrointestinal symptoms despite a GFD was conducted. Patients were randomized to placebo (n = 25) or rifaximin (n = 25) 1,200 mg daily for 10 days. They completed the Gastrointestinal Symptom Rating Scale (GSRS) and underwent lactulose-hydrogen breath tests at weeks 0, 2, and 12. An abnormal breath test was defined as: (1) a rise in hydrogen of ≥20 parts per million (ppm) within 100 min, or (2) two peaks ≥20 ppm over baseline. GSRS scores were unaffected by treatment with rifaximin, regardless of baseline breath tests. In a multivariable regression model, the duration of patients' gastrointestinal symptoms significantly predicted their overall GSRS scores (estimate 0.029, p < 0.006). According to criteria 1 and 2, respectively, SIBO was present in 55 and 8% of patients at baseline, intermittently present in 28 and 20% given placebo, and 28 and 12% given rifaximin. There was no difference in the prevalence of SIBO between placebo and treatment groups at weeks 2 and 12. Rifaximin does not improve patients' reporting of gastrointestinal symptoms and hydrogen breath tests do not reliably identify who will respond to antibiotic therapy.

  19. Low prevalence and incidence of Helicobacter pylori infection in children: a population-based study in Japan.

    PubMed

    Okuda, Masumi; Osaki, Takako; Lin, Yingsong; Yonezawa, Hideo; Maekawa, Kohei; Kamiya, Shigeru; Fukuda, Yoshihiro; Kikuchi, Shogo

    2015-04-01

    Infection of Helicobacter pylori mainly occurs in childhood. In Japan, incidence of gastric cancer is still high in the senior citizen population, but little is known about the current H. pylori infection status among children or their family members. As a population-based study, the prevalence of H. pylori infection and change in infection status over a 1-year interval in children were determined. Family members of some participants were also invited to participate in the study to determine their infection status. All children of specific ages attending 16 schools in Sasayama, Hyogo Prefecture, were invited to participate. H. pylori infection was determined by the stool antigen test and diagnosis confirmed by polymerase chain reaction and the urea breath test. Helicobacter pylori prevalence was 1.9% among 689 children aged 0-8 years in 2010 and 1.8% among 835 children aged 0-11 in 2011. No feco-conversion was observed in 430 children aged 0-8 years (170 were aged 0-4 years) who provided follow-up stool samples after 1 year. The prevalence of infection was 6% (2 of 33) and 38% (6 of 16) in mothers of negative and positive probands (p = .04), respectively, and 12% (3 of 25) and 50% (8 of 16) (p = .01), respectively, in fathers. Helicobacter pylori prevalence in Japanese children is approximately 1.8%, which is much lower than that reported in Japanese adults. New infection may be rare. Parent-to-child infection is thought to be the main infection route of the infrequent infection for children in Japan. © 2014 John Wiley & Sons Ltd.

  20. Helicobacter pylori related dyspepsia: prevalence and treatment outcomes at University Kebangsaan Malaysia-Primary Care Centre

    PubMed Central

    Abdul Aziz, Aznida Firzah; Hamzah, Zuhra; Tong, Seng Fah; Nadeson, Sukumar; Wan Puteh, Sharifa Ezat

    2009-01-01

    Background Optimum management of dyspepsia in primary care is a debatable subject. Testing for Helicobacter pylori (HP) has been recommended in primary care as this strategy will cure most underlying peptic ulcer disease and prevent future gastro duodenal disease. Methods A total of 98 patients completed Modified Glasgow Dyspepsia Severity Score Questionnaire (MGDSSQ) at initial presentation before undergoing the 13Carbon Urea Breath Test (UBT) for HP. Those with positive UBT received Eradication Therapy with oral Omeprazole 20 mg twice daily, Clarithromycin 500 mg daily and Amoxycillin 500 mg twice daily for one week followed by Omeprazole to be completed for another 4 to 6 weeks. Those with negative UBT received empirical treatment with oral Omeprazole 20 mg twice daily for 4 to 6 weeks. Patients were assessed again using the MGDSSQ at the completion of treatment and one month after stopping treatment. Results The prevalence of dyspepsia at Universiti Kebangsaan Malaysia-Primary Care Centre was 1.12% (124/11037), out of which 23.5% (23/98) was due to HP. Post treatment assessment in both HP (95.7%, 22/23) and non HP-related dyspepsia (86.7%, 65/75) groups showed complete or almost complete resolution of dyspepsia. Only about 4.3% (1/23) in the HP related dyspepsia and 13.3% (10/75) in the non HP group required endoscopy. Conclusion The prevalence of dyspepsia due to HP in this primary care centre was 23.5%. Detection of HP related dyspepsia yielded good treatment outcomes (95.7%). PMID:19435494

  1. Intrafamilial transmission of Helicobacter pylori: genotyping of faecal samples.

    PubMed

    Mamishi, Setareh; Eshaghi, Hamid; Mahmoudi, Shima; Bahador, Abbas; Hosseinpour Sadeghi, Reihaneh; Najafi, Mehri; Farahmand, Fatemeh; Khodadad, Ahmad; Pourakbari, Babak

    2016-01-01

    After more than 20 years of research, there is a little information about the detailed routes of Helicobacter pylori transmission. The aim of this study was to explore intrafamilial transmission of H. pylori in children who had indication for upper gastrointestinal endoscopy and their parents. Children (aged up to 15 years) were studied during September 2012 to October 2013. The parents of those with positive urea breath test results were asked to provide faecal and blood samples after giving informed consent. Non-invasive tests such as immunoassay for serological antibodies against H. pylori and detection of its antigen in faeces were measured. The genetic similarity of the family strains was investigated by the random amplification of polymorphic DNA (RAPD-PCR) genotyping method. According to the genotyping results of 30 families, in 10 (33.3%) children related H. pylori genotypes to their mothers were found, while only 2 children (6.7%) had similar genotypes to their fathers. Interestingly, children with similar H. pylori genotype with their mothers had higher IgA (35.7 ± 10.8) and IgM antibody titres (87.23 ± 19.15) than other children. In addition, in these children, lower titres of IgG antibodies (9.93 ± 3.31) were found rather than children who had no H. pylori in their faeces or had no similarities with their parents (30.28 ± 6.15). In conclusion, mother-to-child transmission is the main route of intrafamilial transmission of H. pylori in Iranian families. Molecular typing of H. pylori can be useful in identifying a high-risk population.

  2. Helicobacter pylori eradication and histopathological esophagitis in dyspeptic patients.

    PubMed

    Amini, Mohsen; Karbasi, Ashraf; Khedmat, Hossein; Jeihounian, Mojgan

    2010-01-01

    The association of Helicobacterpylori with peptic ulcer disease, atrophic gastritis, gastric adenocarcinoma, MALT (mucosa associated lymphoid tissue) lymphoma is well recognized. This study was conducted to see whether there was any relation between H. pylori eradication and reflux esophagitis in Iran. Eligible dyspeptic patients referred to Gastroenterology clinic in Baqiyatollah hospital were endoscopied and evaluated for endoscopic and pathologic esophagitis and the H. pylori infection status was determined by rapid urease test. H. pylori infection was treated by an anti H. pylori drug regimen and successfully eradicated patients according to negative C14 urea breath test were followed and re-endoscopy was performed 6-9 months after the end of treatment. From 175 eligible patients, 54% were H. pylori positive, 68 of them (72%) had successful H.P. eradication and 64 patients completed the follow-up. The rate of histopathologic inflammatory esophagitis was higher in second endoscopy, compared with that of first endoscopy, i.e., before H. pylori eradication (75% vs 40.6%) (p < 0.05). Progression of pathological esophagitis was seen in 56.3% of patients between the two endoscopic evaluations in spite of no change in clinical and endoscopic findings. There were no significant differences in dietary and smoking habits and body weights on re-endoscopy session compared with that of the first endoscopy visit (p > 0.05). This study suggests that H. pylori eradication in dyspeptic patients may lead to increased frequency of histopathological esophagitis. Hence, In patients presenting with symptoms of dyspepsia, a cautious approach should be exercised if H. pylori eradication is being contemplated.

  3. The Effects of Broccoli Sprout Extract Containing Sulforaphane on Lipid Peroxidation and Helicobacter pylori Infection in the Gastric Mucosa

    PubMed Central

    Chang, Young Woon; Jang, Jae Young; Kim, Yong Ho; Kim, Jung-Wook; Shim, Jae-Jun

    2015-01-01

    Background/Aims The aims of this study were to investigate whether a broccoli sprout extract containing sulforaphane (BSES) inhibited the Helicobacter pylori infection density and exerted an antioxidative effect on gastric mucosal damage. Methods The enrolled subjects were randomized in a double-blinded manner into three groups. Finally, 33 H. pylori (+) BSES treatment subjects (group A), 28 H. pylori (+) placebo subjects (group B), and 28 H. pylori (−) BSES treatment subjects (group C) were studied. H. pylori infection density was indirectly quantified by a 13C-urea breath test (UBT), and the ammonia concentration in gastric juice aspirates was measured through gastroscopic examination. Malondialdehyde (MDA), an oxidative damage biomarker, and reduced glutathione (GSH), an antioxidant biomarker, were measured in the gastric mucosa by an enzyme-linked immunosorbent assay. Results BSES treatment did not significantly affect the UBT values or ammonia concentration in group A (p=0.634 and p=0.505, respectively). BSES treatment did significantly reduce mucosal MDA concentrations in group A (p<0.05) and group C (p<0.001), whereas the gastric mucosal GSH concentrations did not differ before and after treatment in any of the groups. Conclusions BSES did not inhibit the H. pylori infection density. However, BSES prevented lipid peroxidation in the gastric mucosa and may play a cytoprotective role in H. pylori-induced gastritis. PMID:25287166

  4. Compounded Levofloxacin Triple Therapy is Safe and Effective for Refractory Helicobacter pylori.

    PubMed

    Mah, Xian-Jun; Gupta, Vikas; Loch, Srey Neth; Ahlenstiel, Golo; Poorten, David van de

    2017-01-01

    Failure of first line and subsequent Helicobacter pylori therapy is a significant problem, as alternate treatments are cumbersome and difficult to access. The purpose of this study was to evaluate the efficacy and safety of a compounded levofloxacin triple therapy in clinical practice as a second or third-line salvage regimen for Helicobacter pylori. Patients referred after first or subsequent treatment failures were prescribed compounded levofloxacin 500 mg, amoxicillin 1 g, and esomeprazole 40 mg, all twice daily for 10 days. Eradication success was determined by 14C-urea breath test or histology at least 4 weeks after completion of therapy. The study included 93 patients, the majority of whom were female (57%) with a mean age of 44. The most common indication for treatment was dyspepsia/risk reduction (84%). Median number of previous treatments was 1 (range: 1 through 6) with treatment used as second line in 83%. Helicobacter pylori eradication was achieved in 89.2% (74/83) per protocol and 79.6% (74/93) on an intention-to-treat basis. Outcome was independent of gender, ethnicity, treatment indication, or number. Treatment was well tolerated, with minor adverse events in 8.4% and only one patient discontinuing therapy. Compounded levofloxacin triple therapy is an effective and safe second line treatment for Helicobacter pylori, with eradication rates comparable to standard levofloxacin-based regimens. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  5. Pharmacogenetics of esomeprazole or rabeprazole-based triple therapy in Helicobacter pylori eradication in Hong Kong non-ulcer dyspepsia Chinese subjects.

    PubMed

    Lee, V W Y; Chau, T S; Chan, A K W; Lee, K K C; Waye, M M Y; Ling, T K W; Chan, F K L

    2010-06-01

    Our study aimed to assess the effectiveness of esomeprazole or rabeprazole in combination with amoxicillin and clarithromycin for the eradication of Helicobacter pylori in Hong Kong non-ulcer dyspepsia (NUD) patients. A prospective clinical trial was conducted at the Alice Ho Miu ling Nethersole Hospital outpatient endoscopy center from June 2004 to December 2005. Participants received amoxicillin 1 g, clarithromycin 500 mg, and, esomeprazole 20 mg (EAC) or rabeprazole 20 mg (RAC), all given twice daily for 1 week. The H. pylori status was determined by the [13C] urea breath test at least 4 weeks after completion of the treatment. Mutation status of CYP2C19 in exon 4 and exon 5 associated with the poor metabolizer phenotype was determined. The intention-to-treat eradication rates in patients treated with RAC and EAC were 77% and 84.6% respectively, and per protocol-based eradication rates were 83.7% and 88.9% respectively. The eradication rates did not vary with CYP2C19 phenotype found. For clarithromycin-sensitive strains, the cure rates were statistically significant regardless of CYP2C19 polymorphism (P < 0.0001). Triple therapy with either EAC or RAC is effective for Hong Kong Chinese NUD patients with H. pylori infection. Success eradication was related to clarithromycin resistance and not CYP2C19 genotype.

  6. Assessment of ileal function by abdominal counting of the retention of a gamma emitting bile acid analogue.

    PubMed Central

    Thaysen, E H; Orholm, M; Arnfred, T; Carl, J; Rødbro, P

    1982-01-01

    In eight patients without gastrointestinal complaints and 30 patients with various gastrointestinal disorders ileal bile acid conservation was assessed by oral administration of 75Se 23-selena-25-homocholic acid (SeHCAT) followed by abdominal gamma counting (SeHCAT-test). The results of the test correlated fairly well with the clinical features and with the [1-14C]-cholylglycine breath test including faecal 14C measurements (breath test). Of the two bile acid absorption tests the new is perhaps the more sensitive and is the one most easily performed. PMID:7117906

  7. Effects of slow breathing rate on heart rate variability and arterial baroreflex sensitivity in essential hypertension.

    PubMed

    Li, Changjun; Chang, Qinghua; Zhang, Jia; Chai, Wenshu

    2018-05-01

    This study is to investigate the effects of slow breathing on heart rate variability (HRV) and arterial baroreflex sensitivity in essential hypertension.We studied 60 patients with essential hypertension and 60 healthy controls. All subjects underwent controlled breathing at 8 and 16 breaths per minute. Electrocardiogram, respiratory, and blood pressure signals were recorded simultaneously. We studied effects of slow breathing on heart rate, blood pressure and respiratory peak, high-frequency (HF) power, low-frequency (LF) power, and LF/HF ratio of HRV with traditional and corrected spectral analysis. Besides, we tested whether slow breathing was capable of modifying baroreflex sensitivity in hypertensive subjects.Slow breathing, compared with 16 breaths per minute, decreased the heart rate and blood pressure (all P < .05), and shifted respiratory peak toward left (P < .05). Compared to 16 breaths/minute, traditional spectral analysis showed increased LF power and LF/HF ratio, decreased HF power of HRV at 8 breaths per minute (P < .05). As breathing rate decreased, corrected spectral analysis showed increased HF power, decreased LF power, LF/HF ratio of HRV (P < .05). Compared to controls, resting baroreflex sensitivity decreased in hypertensive subjects. Slow breathing increased baroreflex sensitivity in hypertensive subjects (from 59.48 ± 6.39 to 78.93 ± 5.04 ms/mm Hg, P < .05) and controls (from 88.49 ± 6.01 to 112.91 ± 7.29 ms/mm Hg, P < .05).Slow breathing can increase HF power and decrease LF power and LF/HF ratio in essential hypertension. Besides, slow breathing increased baroreflex sensitivity in hypertensive subjects. These demonstrate slow breathing is indeed capable of shifting sympatho-vagal balance toward vagal activities and increasing baroreflex sensitivity, suggesting a safe, therapeutic approach for essential hypertension.

  8. Pharmacological effects of primaquine ureas and semicarbazides on the central nervous system in mice and antimalarial activity in vitro.

    PubMed

    Kedzierska, Ewa; Orzelska, Jolanta; Perković, Ivana; Knežević, Danijel; Fidecka, Sylwia; Kaiser, Marcel; Zorc, Branka

    2016-02-01

    New primaquine (PQ) urea and semicarbazide derivatives 1-4 were screened for the first time for central nervous system (CNS) and antimalarial activity. Behavioural tests were performed on mice. In vitro cytotoxicity on L-6 cells and activity against erythrocytic stages of Plasmodium falciparum was determined. Compound 4 inhibited 'head-twitch' responses and decreased body temperature of mice, which suggests some involvement of the serotonergic system. Compound 4 protected mice against clonic seizures and was superior in the antimalarial test. A hybrid of two PQ urea 2 showed a strong antimalarial activity, confirming the previous findings of the high activity of bis(8-aminoquinolines) and other bisantimalarial drugs. All the compounds decreased the locomotor activity of mice, what suggests their weak depressive effects on the CNS, while PQ derivatives 1 and 2 increased amphetamine-induced hyperactivity. None of the compounds impaired coordination, what suggests a lack of their neurotoxicity. All the tested compounds presented an antinociceptive activity in the 'writhing' test. Compounds 3 and 4 were active in nociceptive tests, and those effects were reversed by naloxone. Compound 4 could be a useful lead compound in the development of CNS active agents and antimalarials, whereas compound 3 may be considered as the most promising lead for new antinociceptive agents. © 2015 Société Française de Pharmacologie et de Thérapeutique.

  9. Proportional assist ventilation system based on proportional solenoid valve control.

    PubMed

    Lua, A C; Shi, K C; Chua, L P

    2001-07-01

    A new proportional assist ventilation (PAV) method using a proportional solenoid valve (PSV) to control air supply to patients suffering from respiratory disabilities, was studied. The outlet flow and pressure from the proportional solenoid valve at various air supply pressures were tested and proven to be suitable for pressure and flow control in a PAV system. In vitro tests using a breathing simulator, which has been proven to possess the general characteristics of human respiratory system in spontaneous breathing tests, were conducted and the results demonstrated the viability of this PAV system in normalizing the breathing patterns of patients with abnormally high resistances and elastances as well as neuromuscular weaknesses. With a back-up safety mechanism incorporated in the control program, pressure "run-away" can be effectively prevented and safe operation of the system can be guaranteed.

  10. Evaluation of fertilizer and water management effect on rice performance and greenhouse gas intensity in different seasonal weather of tropical climate.

    PubMed

    Ku, Hyun-Hwoi; Hayashi, Keiichi; Agbisit, Ruth; Villegas-Pangga, Gina

    2017-12-01

    Intensively double cropping rice increases greenhouse gas (GHG) emission in tropical countries, and hence, finding better management practices is imperative for reducing global warming potential (GWP), while sustaining rice yield. This study demonstrated an efficient fertilizer and water management practice targeting seasonal weather conditions effects on rice productivity, nitrogen use efficiency (NUE), GWP, and GHG intensity (GHGI). Two-season experiments were conducted with two pot-scale experiments using urea and urea+cattle manure (CM) under continuous flooding (CF) during the wet season (2013WS), and urea with/without CaSiO 3 application under alternate wetting and drying (AWD) during the dry season (2014DS). In 2013WS, 120kgNha -1 of urea fertilizer resulted in lower CH 4 emission and similar rice production compared to urea+CM. In 2014DS, CaSiO 3 application showed no difference in yields and led to significant reduction of N 2 O emission, but increased CH 4 emission and GWP. Due to significant increases in GHG emissions in urea+CM and CaSiO 3 application, we compared a seasonal difference in a local rice cultivation to test two water management practices. CF was adopted during 2013WS while AWD was adopted during 2014DS. Greater grain yields and yield components and NUE were obtained in 2014DS than in 2013WS. Furthermore, higher grain yields contributed to similar values of GHGI although GWP of cumulative GHG emissions was increased in 2014DS. Thus, utilizing urea only application under AWD is a preferred practice to minimize GWP without yield decline for double cropping rice in tropical countries. Copyright © 2017. Published by Elsevier B.V.

  11. Salivary flow rate, buffer capacity, and urea concentration in adolescents with type 1 diabetes mellitus.

    PubMed

    Saes Busato, Ivana Maria; Antoni, Carlos Cesar De; Calcagnotto, Thiago; Ignácio, Sérgio Aparecido; Azevedo-Alanis, Luciana Reis

    2016-12-01

    The objective of the study was to analyze salivary flow rate, urea concentration, and buffer capacity in adolescents with type 1 diabetes mellitus (type 1 DM) in two different stages. This study was performed on adolescents (14-19 years), allocated between two groups: type 1 DM group comprised 32 adolescents with type 1 DM, and non-type 1 DM group comprised 32 nondiabetics. The adolescents in type 1 DM group were evaluated at a baseline (T0) and after 15 months (T1), and those in non-type 1 DM group were only evaluated at T0. Diabetic status was determined by glycosylated hemoglobin (GHb) and capillary glucose tests. Measurement of salivary flow was performed by means of stimulated saliva (SSFR) collection. The buffer capacity (BC) was determined, and analysis of urea salivary concentration was performed using the colorimetric method. At T0, there were significant differences between diabetics and nondiabetics for SSFR and BC (p<0.05). In diabetics, SSFR was 0.790 mL/min in T0 and 0.881 mL/min in T1 (p>0.05). BC at T0 was 4.8, and at T1, it was 3.9 (p=0.000). Urea concentration mean value had a significant decrease at T1 (28.13) compared with T0 (34.88) (p=0.013). There was a negative correlation between SSFR and urea salivary concentration at both T0 (r=-0.426, p≤0.05) and T1 (r=-0.601, p≤0.01). In adolescents with type 1 DM, hyposalivation at T0 was associated with an increase in urea salivary concentration. At T1, hyposalivation was associated with a reduction in BC, and an increase in salivary urea.

  12. Nitrogen test (image)

    MedlinePlus

    ... is performed to check for the amount of urea in urine. Urine is collected over a 24 hour period and is sent to the laboratory for testing. This test is mainly used to assess the amount of dietary protein needed by severely ill patients.

  13. Ammonia excretion increased and urea excretion decreased in urine of a new world nectarivorous bat with decreased nitrogen intake.

    PubMed

    Herrera M, L Gerardo; Ramirez P, Nicte; Miron M, Leticia

    2006-01-01

    We determined the effect of water and nitrogen intake on nitrogenous waste composition in the nectarivorous Pallas's long-tongued bat Glossophaga soricina (Phyllostomidae) to test the hypothesis that bats reduce excretion of urea nitrogen and increase the excretion of ammonia nitrogen as nitrogen intake decreases and water intake decreases. Because changes in urine nitrogen composition are expected only in animals whose natural diets are low in nitrogen and high in water content, we also measured maintenance nitrogen requirements (MNR). We hypothesized that, similar to other plant-eating vertebrates, nectarivorous bats have low MNR. Our nitrogen excretion hypothesis was partly proved correct. There was an increase in the proportion of N excreted as ammonia and a decrease in the proportion excreted as urea in low-nitrogen diets. The proportion of N excreted as ammonia and urea was independent of water intake. Most individuals were ureotelic (n = 28), and only a few were ureo-ammonotelic (n = 3) or ammonotelic (n = 2). According to our nitrogen requirement hypothesis, apparent MNR (60 mg kg(-0.75) d(-1)) and truly digestible MNR (54 mg N kg(-0.75) d(-1)) were low. A decrease in urea excretion in low-nitrogen diets may result from urea recycling from liver to the gut functioning as a nitrogen salvage system in nectarivorous bats. This mechanism probably contributes to the low MNR found in Pallas's long-tongued bats.

  14. Effect of Yogic Breathing on Accommodate Braille Version of Six-letter Cancellation Test in Students with Visual Impairment.

    PubMed

    Pradhan, Balaram; Mohanty, Soubhagyalaxmi; Hankey, Alex

    2018-01-01

    Attentional processes tend to be less well developed in the visually impaired, who require special training to develop them fully. Yogic breathing which alters the patterns of respiration has been shown to enhance attention skills. Letter cancellation tests are well-established tools to measure attention and attention span. Here, a modified Braille version of the six-letter cancellation test (SLCT) was used for students with visual impairment (VI). This study aimed to assess the immediate effects of Bhramari Pranayama (BhPr) and breath awareness (BA) on students with VI. This study was a self-as-control study held on 2 consecutive days, on 19 participants (8 males, 11 females), with a mean age of 15.89 ± 1.59 years, randomized into two groups. On the 1 st day, Group 1 performed 10 min breath awareness and Group 2 performed Bhramari ; on the 2 nd day, practices were reversed. Assessments used a SLCT specially adapted for the visually impaired before and after each session. The Braille letter cancellation test was successfully taken by 19 students. Scores significantly improved after both techniques for each student following practices on both days ( P < 0.001). BhPr may have more effect on attention performance than BA as wrong scores significantly increased following BA ( P < 0.05), but the increase in the score after Bhramari was not significant. Despite the small sample size improvement in attentional processes by both yoga breathing techniques was robust. Attentional skills were definitely enhanced. Long-term practice should be studied.

  15. Effect of Yogic Breathing on Accommodate Braille Version of Six-letter Cancellation Test in Students with Visual Impairment

    PubMed Central

    Pradhan, Balaram; Mohanty, Soubhagyalaxmi; Hankey, Alex

    2018-01-01

    Context: Attentional processes tend to be less well developed in the visually impaired, who require special training to develop them fully. Yogic breathing which alters the patterns of respiration has been shown to enhance attention skills. Letter cancellation tests are well-established tools to measure attention and attention span. Here, a modified Braille version of the six-letter cancellation test (SLCT) was used for students with visual impairment (VI). Aim: This study aimed to assess the immediate effects of Bhramari Pranayama (BhPr) and breath awareness (BA) on students with VI. Methods: This study was a self-as-control study held on 2 consecutive days, on 19 participants (8 males, 11 females), with a mean age of 15.89 ± 1.59 years, randomized into two groups. On the 1st day, Group 1 performed 10 min breath awareness and Group 2 performed Bhramari; on the 2nd day, practices were reversed. Assessments used a SLCT specially adapted for the visually impaired before and after each session. Results: The Braille letter cancellation test was successfully taken by 19 students. Scores significantly improved after both techniques for each student following practices on both days (P < 0.001). BhPr may have more effect on attention performance than BA as wrong scores significantly increased following BA (P < 0.05), but the increase in the score after Bhramari was not significant. Conclusions: Despite the small sample size improvement in attentional processes by both yoga breathing techniques was robust. Attentional skills were definitely enhanced. Long-term practice should be studied. PMID:29755219

  16. Lactulose Breath Test Gas Production in Childhood IBS Is Associated With Intestinal Transit and Bowel Movement Frequency.

    PubMed

    Chumpitazi, Bruno P; Weidler, Erica M; Shulman, Robert J

    2017-04-01

    In adults with irritable bowel syndrome (IBS), bacterial gas production (colonic fermentation) is related to both symptom generation and intestinal transit. Whether gas production affects symptom generation, psychosocial distress, or intestinal transit in childhood IBS is unknown. Children (ages 7-17 years) with pediatric Rome III IBS completed validated psychosocial questionnaires and a 2-week daily diary capturing pain and stooling characteristics. Stool form determined IBS subtype. Subjects then completed a 3-hour lactulose breath test for measurement of total breath hydrogen and methane production. Carmine red was used to determine whole intestinal transit time. A total of 87 children (mean age 13 ± 2.6 [standard deviation] years) were enrolled, of whom 50 (57.5%) were girls. All children produced hydrogen and 51 (58.6%) produced methane. Hydrogen and methane production did not correlate with either abdominal pain frequency/severity or psychosocial distress. Hydrogen and methane production did not differ significantly by IBS subtype. Methane production correlated positively with whole intestinal transit time (r = 0.31, P < 0.005) and inversely with bowel movement frequency (r = -0.245, P < 0.05). Methane production (threshold 3 ppm) as a marker for identifying IBS-C had a sensitivity of 60% and specificity of 42.9%. Lactulose breath test total methane production may serve as a biomarker of whole intestinal transit time and bowel movement frequency in children with IBS. In children with IBS, lactulose breath test hydrogen and methane production did not, however, correlate with abdominal pain, IBS subtype, or psychosocial distress.

  17. In vitro interference by acetaminophen, aspirin, and metamizole in serum measurements of glucose, urea, and creatinine.

    PubMed

    Luna-Záizar, Hilda; Virgen-Montelongo, María; Cortez-Álvarez, Cesar R; Ruiz-Quezada, Sandra L; Escutia-Gutiérrez, Raymundo; García-Lemus, Cuauhtémoc R; Mendizabal-Ruiz, Adriana P

    2015-05-01

    Here we aimed to investigate the in vitro effects of three analgesic-antipyretic drugs frequently used in clinical practice in Mexico - acetaminophen (AAP), aspirin (ASA) and metamizole (MMZ) - on serum measurements of glucose, urea, and creatinine. Each analyte was measured in a base-serum pool spiked with the drugs at subtherapeutic, therapeutic, and toxic doses. Serum glucose and urea were measured using the hexokinase/G-6PDH and urease/GLDH kinetic assays, respectively. Serum creatinine (SCr) was measured with a Jaffe procedure based on the alkaline-picrate reaction and with an enzymatic dry-chemistry system. Measurements were carried out in IL-Monarch and Vitros DT60-II analyzers, respectively. Data were analyzed by the difference-paired interference test and by ANOVA. By the kinetic Jaffe/Monarch procedure, we found positive interference by the drugs on the SCr measurements and by only ASA for urea measurement. For creatinine measurements, the total errors (TEs) were 22-51%, 18-105%, and 15-26% for AAP, ASA, and MMZ respectively, while for urea measurement the TE was 16-21% for ASA. A negative interference by MMZ on SCr (TE=-47%), but no-interference for AAP or ASA, were found via the enzymatic/DT60-II system. In vitro positive interference induced by AAP, ASA, and MMZ (via the alkaline-picrate reaction), or negative interference by MMZ (via a dry-chemistry system), on the SCr measurements highlights the importance of investigating all possible sources of variation that may alter the accuracy of the laboratory tests, in order to provide useful results for making medical decisions for optimal patient care. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Unusual hepatic mitochondrial arginase in an Indian air-breathing teleost, Heteropneustes fossilis: purification and characterization.

    PubMed

    Srivastava, Shilpee; Ratha, B K

    2013-02-01

    A functional urea cycle with both cytosolic (ARG I) and mitochondrial (ARG II) arginase activity is present in the liver of an ureogenic air-breathing teleost, Heteropneustes fossilis. Antibodies against mammalian ARG II showed no cross-reactivity with the H. fossilis ARG II. ARG II was purified to homogeneity from H. fossilis liver. Purified ARG II showed a native molecular mass of 96 kDa. SDS-PAGE showed a major band at 48 kDa. The native enzyme, therefore, appears to be a homodimer. The pI value of the enzyme was 7.5. The purified enzyme showed maximum activity at pH 10.5 and 55 °C. The K(m) of purified ARG II for l-arginine was 5.25±1.12 mM. L-Ornithine and N(ω)-hydroxy-L-arginine showed mixed inhibition with K(i) values 2.16±0.08 and 0.02±0.004 mM respectively. Mn(+2) and Co(+2) were effective activators of arginase activity. Antibody raised against purified H. fossilis ARG II did not cross-react with fish ARG I, and mammalian ARG I and ARG II. Western blot with the antibodies against purified H. fossilis hepatic ARG II showed cross reactivity with a 96 kDa band on native PAGE and a 48 kDa band on SDS-PAGE. The molecular, immunological and kinetic properties suggest uniqueness of the hepatic mitochondrial ARG II in H. fossilis. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. The accuracy of evidential breath testers at low BACs

    DOT National Transportation Integrated Search

    1989-05-01

    This Technical Note reports on the low blood alcohol concentration (BAC) laboratory testing of seven evidential breath testers widely used by law enforcement. The findings indicated that these devices are just as accurate at low BACs in the 0.020-0.0...

  20. Use of warrants for breath test refusal : case studies

    DOT National Transportation Integrated Search

    2007-10-01

    This study investigated the use of warrants to obtain blood samples from drivers arrested for alcohol-impaired driving and who refuse to provide breath samples when requested to do so by law enforcement officers. Case studies were conducted in four S...

Top