Sample records for ureteroscopic holmium laser

  1. Ureteroscopic holmium laser cutting for inadvertently sutured drainage tube (report of five cases).

    PubMed

    Gao, Xu; Lu, Xin; Ren, Shancheng; Xu, Chuanliang; Sun, Yinghao

    2008-07-01

    The aim of this paper is to report a simple solution for inadvertently sutured drainage tube after urological surgery and discuss the different managements according to different types of this embarrassing complication. From September 2001 to January 2007, five inadvertently sutured drainage tubes were treated with ureteroscopic holmium laser cutting for the suture. All drainage tubes were removed after the operation without other complications. Holmium laser cutting via ureteroscope is a simple solution for the embarrassing problem of inadvertently sutured drainage tube. It can save the patient from undergoing another open surgery.

  2. Advances in laser technology and fibre-optic delivery systems in lithotripsy.

    PubMed

    Fried, Nathaniel M; Irby, Pierce B

    2018-06-08

    The flashlamp-pumped, solid-state holmium:yttrium-aluminium-garnet (YAG) laser has been the laser of choice for use in ureteroscopic lithotripsy for the past 20 years. However, although the holmium laser works well on all stone compositions and is cost-effective, this technology still has several fundamental limitations. Newer laser technologies, including the frequency-doubled, double-pulse YAG (FREDDY), erbium:YAG, femtosecond, and thulium fibre lasers, have all been explored as potential alternatives to the holmium:YAG laser for lithotripsy. Each of these laser technologies is associated with technical advantages and disadvantages, and the search continues for the next generation of laser lithotripsy systems that can provide rapid, safe, and efficient stone ablation. New fibre-optic approaches for safer and more efficient delivery of the laser energy inside the urinary tract include the use of smaller-core fibres and fibres that are tapered, spherical, detachable or hollow steel, or have muzzle brake distal fibre-optic tips. These specialty fibres might provide advantages, including improved flexibility for maximal ureteroscope deflection, reduced cross section for increased saline irrigation rates through the working channel of the ureteroscope, reduced stone retropulsion for improved stone ablation efficiency, and reduced fibre degradation and burnback for longer fibre life.

  3. Flexible Ureteroscopic Management of Horseshoe Kidney Renal Calculi.

    PubMed

    Ding, Jie; Huang, Yunteng; Gu, Siping; Chen, Yifan; Peng, Jie; Bai, Qiang; Ye, Min; Qi, Jun

    2015-01-01

    To evaluate the clinical efficacy of flexible ureteroscope (F-URS) combined with holmium laser lithotripter in treating renal calculi in horseshoe kidney. From November 2010 to December 2013, the medical history and charts of sixteen patients (mean age 42.9 ± 11.6 years, range 26-66 years), including 13 males and 3 females were analyzed retrospectively. Mean stone burden was 29 ± 8 mm (range 17-42 mm2). Mean stone digitized surface area (DSA) was 321 ± 94 mm2 (range 180-538 mm2). Under spinal anesthesia in a modified lithotomy position with the head down, rigid ureteroscope was placed firstly into the ureter to reach the level of the pelvis, a zebra guide wire was inserted and following the removal of the rigid ureteroscope, an ureteral access sheath was positioned along the guide wire, then passed the URF P-5 flexible ureteroscope into the renal cavities over the guidewire. After locating the stones, holmium laser lithotripsy was performed. The average operative time was 92 ± 16 minutes (range 74-127 min.). No major complications were encountered. Ten patients obtained stone-free status with one session, four obtained stone-free status after two sessions. Single session stone-free rate was 62.5%, overall stone-free rate was 87.5%. Two patients have small residual stones in the lower pole. F-URS combined with holmium laser lithotripter and nitinol basket, is safe and effective in dealing with moderate stone diameter (<30 mm) in HSKs with high clearance rates and low complication rates.

  4. Impressive Performance: New Disposable Digital Ureteroscope Allows for Extreme Lower Pole Access and Use of 365 μm Holmium Laser Fiber.

    PubMed

    Leveillee, Raymond J; Kelly, Emily Fell

    2016-01-01

    Since the development of the first flexible ureteroscope, in 1964, technological advances in image quality, flexibility, and deflection have led to the development of the first single-use digital flexible ureteroscope, LithoVue™ (Boston Scientific, Marlborough, MA). With respect to reusable fiber-optic and now digital ureteroscopes, there is an initial capital cost of several thousand dollars (USD) as well as, controversy regarding durability, the cost of repairs and the burdensome reprocessing steps of ureteroscopy. The single-use LithoVue eliminates the need for costly repairs, the occurrence of unpredictable performance, and procedural delays. Renal stones located in the lower pole of the kidney can be extremely challenging as extreme deflections of greater than 160° are difficult to maintain and are often further compromised when using stone treatment tools, such as laser fibers and baskets. This case describes an initial use of the LithoVue digital disposable ureteroscope in the effective treatment of lower pole calculi using a 365 μm holmium laser fiber. A 35-year-old female, with a medical history significant for chronic bacteriuria, and recurrent symptomatic culture proven urinary tract infections, underwent localization studies. Retrograde ureteropyelography demonstrated two calcifications adjoining, measuring a total of 1.4 cm, overlying the left renal shadow. Urine aspirated yielded clinically significant, >100,000, Escherichia coli and Streptococcus anginosus bacteriuria, which was felt to be originating from the left lower calix. This case used the newly FDA-approved LithoVue flexible disposable ureteroscope. The two stones were seen using the ureteroscope passed through an ureteral access sheath in the lower pole calix. A 365 μm holmium laser fiber was inserted into the ureteroscope and advanced toward the stones. There was no loss of deflection as the ureteroscope performed reproducibly. The laser was used for more than 4000 pulses at 15 W, producing mucoid debris and fragments. A 1.9F nitinol basket was, then, used to extract the fragments, and the patient was rendered stone free. Treatment success was confirmed by plain abdominal film obtained 1 week after stent removal. The LithoVue system single-use digital flexible ureteroscope provides an economical advantage over both reusable digital and fiber-optic ureteroscopes. The LithoVue system uses the enhanced image resolution of the digital complementary metal oxide semiconductor imager, similar to other reusable digital ureteroscopes, while maintaining the small ureteroscope size of a flexible fiber-optic ureteroscope, allowing for consistent and effective lower pole access. Deflection characteristics are maintained even when thicker laser fibers are passed through the working channel.

  5. Prospective analysis of a complete retrograde ureteroscopic technique with holmium laser stent cutting for management of encrusted ureteral stents.

    PubMed

    Thomas, Alexandre; Cloutier, Jonathan; Villa, Luca; Letendre, Julien; Ploumidis, Achilles; Traxer, Olivier

    2017-03-14

    To propose and evaluate a new endoscopic technique using only a retrograde ureteroscopic approach for the removal of heavily encrusted ureteral stents. Data from 51 consecutive patients with encrusted and retained ureteral stents were prospectively collected. Description of the successive steps of surgery is detailed. The Holmium-YAG laser properties offer the opportunity for fragmentation of stent-attached encrustation and the ability to cut the stent itself. Reducing the length of the stent is critical to creating space in the ureter and to allow free access for ureteroscopes or ureteral access sheath placement. The primary outcome of this study was the feasibility and the safety of this retrograde intra-renal approach. Some factors of encrustation and outcomes are also discussed in comparison with lithotripsy, percutaneous, laparoscopic, open surgery or a combination of these techniques. The removal of the encrusted stent was possible with only this retrograde technique in 98% of patients. The transection of the encrusted stent with the Holmium-YAG laser was useful in 71% of the patients. Mean operative time was 110 minutes and mean hospital stay was 2.33 days. Postoperative complications were mainly non-obstructive pyelonephritis (10%). The most significant predictor of this life threatened complication was the presence of struvite stones with the encrusted stent (p=0,018). Contrariwise, operative time, BMI, gender and encrustation rate were not associated with postoperative pyelonephritis. Cystine stone disease or pregnancy both led to faster stent encrustation. Retrograde ureteroscopic surgery is efficient and safe for removing retained stents and associated stone burdens. The Holmium-YAG laser is essential to perform the encrustation removal and sectioning of the stent.

  6. Flexible Ureteroscopic Management of Horseshoe Kidney Renal Calculi

    PubMed Central

    Ding, Jie; Huang, Yunteng; Gu, Siping; Chen, Yifan; Peng, Jie; Bai, Qiang; Ye, Min; Qi, Jun

    2015-01-01

    ABSTRACT Purpose: To evaluate the clinical efficacy of flexible ureteroscope (F-URS) combined with holmium laser lithotripter in treating renal calculi in horseshoe kidney. Materials and Methods: From November 2010 to December 2013, the medical history and charts of sixteen patients (mean age 42.9±11.6 years, range 26-66 years), including 13 males and 3 females were analyzed retrospectively. Mean stone burden was 29±8 mm (range 17-42 mm2). Mean stone digitized surface area (DSA) was 321±94 mm2 (range 180-538 mm2). Under spinal anesthesia in a modified lithotomy position with the head down, rigid ureteroscope was placed firstly into the ureter to reach the level of the pelvis, a zebra guide wire was inserted and following the removal of the rigid ureteroscope, an ureteral access sheath was positioned along the guide wire, then passed the URF P-5 flexible ureteroscope into the renal cavities over the guidewire. After locating the stones, holmium laser lithotripsy was performed. Results: The average operative time was 92±16 minutes (range 74-127 min.). No major complications were encountered. Ten patients obtained stone-free status with one session, four obtained stone-free status after two sessions. Single session stone-free rate was 62.5%, overall stone-free rate was 87.5%. Two patients have small residual stones in the lower pole. Conclusions: F-URS combined with holmium laser lithotripter and nitinol basket, is safe and effective in dealing with moderate stone diameter (<30 mm) in HSKs with high clearance rates and low complication rates. PMID:26401860

  7. Holmium:YAG laser lithotripsy for upper urinary tract calculi in 598 patients.

    PubMed

    Sofer, Mario; Watterson, James D; Wollin, Timothy A; Nott, Linda; Razvi, Hassan; Denstedt, John D

    2002-01-01

    We assessed the effectiveness and safety of holmium:YAG laser lithotripsy for managing upper urinary tract calculi in a prospective cohort of 598 patients. Ureteroscopic holmium:YAG laser lithotripsy was performed in 598 patients between 1993 and 1999. Calculi were located in the distal ureter in 39.6% of cases, mid ureter in 18.6%, proximal ureter in 32.4% and kidney in 9.4%. Patients were treated on an outpatient basis with various flexible and semirigid endoscopes. Of the cases 59% were referred as previous treatment failures. Patients were assessed 6 to 12 weeks postoperatively with repeat plain x-ray and ultrasound or excretory urography for late obstructive complications. The overall stone-free rate was 97%. As stratified by location, the stone-free rate was 98% in the distal ureter, 100% in the mid ureter, 97% in the proximal ureter and 84% in the kidney. Fragmentation was incomplete in 6% of cases and secondary intervention was required in 6%. The overall complication rate was 4%. New onset ureteral stricture developed postoperatively in 0.35% of patients. Holmium:YAG laser lithotripsy is a highly effective and safe treatment modality for managing ureteral and a proportion of intrarenal calculi on an outpatient basis. The effectiveness and versatility of the holmium laser combined with small rigid or flexible endoscopes make it our modality of choice for ureteroscopic lithotripsy.

  8. Thulium fiber laser ablation of kidney stones using a 50-μm-core silica optical fiber

    NASA Astrophysics Data System (ADS)

    Blackmon, Richard L.; Hutchens, Thomas C.; Hardy, Luke A.; Wilson, Christopher R.; Irby, Pierce B.; Fried, Nathaniel M.

    2015-01-01

    Our laboratory is currently studying the experimental thulium fiber laser (TFL) as a potential alternative laser lithotripter to the gold standard, clinical Holmium:YAG laser. We have previously demonstrated the efficient coupling of TFL energy into fibers as small as 100-μm-core-diameter without damage to the proximal end. Although smaller fibers have a greater tendency to degrade at the distal tip during lithotripsy, fiber diameters (≤200 μm) have been shown to increase the saline irrigation rates through the working channel of a flexible ureteroscope, to maximize the ureteroscope deflection, and to reduce the stone retropulsion during laser lithotripsy. In this study, a 50-μm-core-diameter, 85-μm-outer-diameter, low-OH silica fiber is characterized for TFL ablation of human calcium oxalate monohydrate urinary stones, ex vivo. The 50-μm-core fiber consumes approximately 30 times less cross-sectional area inside the single working channel of a ureteroscope than the standard 270-μm-core fiber currently used in the clinic. The ureteroscope working channel flow rate, including the 50-μm fiber, decreased by only 10% with no impairment of ureteroscope deflection. The fiber delivered up to 15.4±5.9 W under extreme bending (5-mm-radius) conditions. The stone ablation rate measured 70±22 μg/s for 35-mJ-pulse-energy, 500-μs-pulse-duration, and 50-Hz-pulse-rate. Stone retropulsion and fiber burnback averaged 201±336 and 3000±2600 μm, respectively, after 2 min. With further development, thulium fiber laser lithotripsy using ultra-small, 50-μm-core fibers may introduce new integration and miniaturization possibilities and potentially provide an alternative to conventional Holmium:YAG laser lithotripsy using larger fibers.

  9. Holmium laser lithotripsy (HoLL) of ureteral calculi

    NASA Astrophysics Data System (ADS)

    Kuntz, Rainer M.; Lehrich, Karin; Fayad, Amr

    2001-05-01

    The effectiveness and side effects of ureteroscopic HoLL of ureteral stones should be evaluated. In 63 patients (17 female, 46 males) a total of 75 stones of 3-20 mm diameter were treated with ureteroscopic HoLL. 18.7 percent of stones were located in the proximal third, 24.0 percent in the middle third and 57.3 percent in the distal third of the ureter. HoLL was performed with small diameter semirigid and flexible ureteroscopes, 220 or 365 nm flexible laser fibers and a holmium:YAG laser at a power of 5-15 W (0.5-1.0 J, 10- 15 Hz). 47 of 63 patients (74.6 percent) were immediately free of stones, and 8 others (12.6 percent) lost their residual fragments spontaneously within two weeks. Another 2 patients received additional chmolitholysis for uric acid stone fragments, i.e. 90.5 percent of patients were stone free by one sitting of ureterscopic HoLL. Of the remaining 6 patients (9.5 percent) who still had residual calculi 4 weeks after HoLL, 2 asymptomatic patients refused any additional treatment, 2 patients preferred treatment with ESWL, and 2 patients had a successful second HoLL, thereby raising the success rate of ureteroscopic HoLL to 93.7 percent. 2 patients showed contrast medium extravasation on retrograde ureterograms, due to guide wire perforation. No ureteral stricture occurred. In conclusion, transurethral ureteroscopic HoLL proved to be a safe and successful minimal invasive treatment of ureteral calculi.

  10. Thermal Response to High-Power Holmium Laser Lithotripsy.

    PubMed

    Aldoukhi, Ali H; Ghani, Khurshid R; Hall, Timothy L; Roberts, William W

    2017-12-01

    The aim of this study was to investigate "caliceal" fluid temperature changes during holmium laser activation/lithotripsy using settings up to 40 W power output with different irrigation flow rates. The experimental system consisted of a glass test tube (diameter 10 mm/length 75 mm) filled with deionized water, to mimic a calix. Real-time temperature was recorded using a thermocouple (Physitemp, NJ) positioned 5 mm from the bottom of the tube. A 200 μm laser fiber (Flexiva; Boston Scientific, MA) was introduced through the working channel of a disposable ureteroscope (LithoVue; Boston Scientific) and the laser fiber tip was positioned 15 mm above the bottom of the test tube. Deionized water irrigation (room temperature) through the working channel of the ureteroscope was delivered at flow rates of 0, 7-8, 14-15, and 38-40 mL/minute. A 120-W holmium laser (pulse 120; Lumenis, CA) was used. The following settings were explored: 0.5 J × 10 Hz, 1.0 J × 10 Hz, 0.5 J × 20 Hz, 1.0 J × 20 Hz, 0.5 J × 40 Hz, 1.0 J × 40 Hz, and 0.5 J × 80 Hz. During each experiment, the laser was activated continuously for 60 seconds. Temperature increased with increasing laser power output and decreasing irrigation flow rate. The highest temperature, 70.3°C (standard deviation 2.7), occurred with laser setting of 1.0 J × 40 Hz and no irrigation after 60 seconds of continuous laser firing. None of the tested laser settings and irrigation parameters produced temperature exceeding 51°C when activated for only 10 seconds of continuous laser firing. High-power holmium settings fired in long bursts with low irrigation flow rates can generate high fluid temperatures in a laboratory "caliceal" model. Awareness of this risk allows urologist to implement a variety of techniques (higher irrigation flow rates, intermittent laser activation, and potentially cooled irrigation fluid) to control and mitigate thermal effects during holmium laser lithotripsy.

  11. Expanding role of ureteroscopy and laser lithotripsy for treatment of proximal ureteral and intrarenal calculi.

    PubMed

    Bagley, Demetrius H

    2002-07-01

    Ureteroscopy has assumed an expanded and important role in the treatment of proximal ureteral and intrarenal calculi with the development of new endoscopes, more effective grasping devices, and the holmium laser lithotriptor. The success rate for treating proximal ureteral stones with small rigid and flexible ureteroscopes and the holmium laser is well over 90%. Lower pole renal calculi can also be treated with a success rate of approximately 80%, which surpasses that of shock wave lithotripsy. Selected stones that are over 2 cm in diameter, along with branched stones, can also be treated successfully with ureteroscopy. Ureteroscopy is the most successful technique for the treatment of ureteral calculi (success rates >90%) and is an optional treatment for many renal calculi.

  12. Fiber-optic manipulation of urinary stone phantoms using holmium:YAG and thulium fiber lasers.

    PubMed

    Blackmon, Richard L; Case, Jason R; Trammell, Susan R; Irby, Pierce B; Fried, Nathaniel M

    2013-02-01

    Fiber-optic attraction of urinary stones during laser lithotripsy may be exploited to manipulate stone fragments inside the urinary tract without mechanical grasping tools, saving the urologist time and space in the ureteroscope working channel. We compare thulium fiber laser (TFL) high pulse rate/low pulse energy operation to conventional holmium:YAG low pulse rate/high pulse energy operation for fiber-optic suctioning of plaster-of-paris (PoP) stone phantoms. A TFL (wavelength of 1908 nm, pulse energy of 35 mJ, pulse duration of 500 μs, and pulse rate of 10 to 350 Hz) and a holmium laser (wavelength of 2120 nm, pulse energy of 35 to 360 mJ, pulse duration of 300 μs, and pulse rate of 20 Hz) were tested using 270-μm-core optical fibers. A peak drag speed of ~2.5 mm/s was measured for both TFL (35 mJ and 150 to 250 Hz) and holmium laser (210 mJ and 20 Hz). Particle image velocimetry and thermal imaging were used to track water flow for all parameters. Fiber-optic suctioning of urinary stone phantoms is feasible. TFL operation at high pulse rates/low pulse energies is preferable to holmium operation at low pulse rates/high pulse energies for rapid and smooth stone pulling. With further development, this novel technique may be useful for manipulating stone fragments in the urinary tract.

  13. Combined retrograde flexible ureteroscopic lithotripsy with holmium YAG laser for renal calculi associated with ipsilateral ureteral stones.

    PubMed

    Cocuzza, Marcello; Colombo, Jose R; Ganpule, Arvind; Turna, Burak; Cocuzza, Antonio; Dhawan, Divyar; Santos, Bruno; Mazzucchi, Eduardo; Srougi, Miguel; Desai, Mahesh; Desai, Mihir

    2009-02-01

    The purpose of this study was to evaluate the effectiveness of combined ureteroscopic holmium YAG lithotripsy for renal calculi associated with ipsilateral ureteral stones. Between August 2002 and March 2007, retrograde flexible ureteroscopic stone treatment was attempted in 351 cases. Indication for treatment was concurrent symptomatic ureteral stones in 63 patients (group I). Additional operative time and perioperative complication rates were compared to a group of 39 patients submitted to ureteroscopic treatment for ureteral calculi exclusively (group II). Mean ureteral stone size was 8.0 +/- 2.6 mm and 8.1 +/- 3.4 mm for groups I and II, respectively. Mean operative time for group I was 67.9 +/- 29.5 minutes and for group 2 was 49.3 +/- 13.2 minutes (p < 0.001). Flexible ureteroscopic therapy for renal calculi increased 18 minutes in the mean operative time. The overall complication rate was 3.1% and 2.5% for groups I and II, respectively (p = 0.87). Mean renal stone size was 10.7 +/- 6.4 mm, overall stone free rate in group I was 81%. However, considering only patients with renal stones smaller than 15 mm, the stone free rate was 88%. Successful treatment occurred in 81% of patients presenting lower pole stones, but only 76% of patients with multiple renal stones became stone free. As expected, stone free rate showed a significant negative correlation with renal stone size (p = 0.03; r = -0.36). Logistic regression model indicated an independent association of renal stones smaller than 15 mm and stone free rate (OR = 13.5; p = 0.01). Combined ureteroscopic treatment for ureteral and ipsilateral renal calculi is a safe and attractive option for patients presenting for symptomatic ureteral stone and ipsilateral renal calculi smaller than 15 mm.

  14. Kidney stone ablation times and peak saline temperatures during Holmium:YAG and Thulium fiber laser lithotripsy, in vitro, in a ureteral model

    NASA Astrophysics Data System (ADS)

    Hardy, Luke A.; Wilson, Christopher R.; Irby, Pierce B.; Fried, Nathaniel M.

    2015-02-01

    Using a validated in vitro ureter model for laser lithotripsy, the performance of an experimental Thulium fiber laser (TFL) was studied and compared to clinical gold standard Holmium:YAG laser. The Holmium laser (λ = 2120 nm) was operated with standard parameters of 600 mJ, 350 μs, 6 Hz, and 270-μm-core optical fiber. TFL (λ = 1908 nm) was operated with 35 mJ, 500 μs, 150-500 Hz, and 100-μm-core fiber. Urinary stones (60% calcium oxalate monohydrate / 40% calcium phosphate), of uniform mass and diameter (4-5 mm) were laser ablated with fibers through a flexible video-ureteroscope under saline irrigation with flow rates of 22.7 ml/min and 13.7 ml/min for the TFL and Holmium laser, respectively. The temperature 3 mm from tube's center and 1 mm above mesh sieve was measured by a thermocouple and recorded during experiments. Total laser and operation times were recorded once all stone fragments passed through a 1.5-mm sieve. Holmium laser time measured 167 +/- 41 s (n = 12). TFL times measured 111 +/- 49 s, 39 +/- 11 s, and 23 +/- 4 s, for pulse rates of 150, 300, and 500 Hz (n = 12 each). Mean peak saline irrigation temperatures reached 24 +/- 1 °C for Holmium, and 33 +/- 3 °C, 33 +/- 7 °C, and 39 +/- 6 °C, for TFL at pulse rates of 150, 300, and 500 Hz. To avoid thermal buildup and provide a sufficient safety margin, TFL lithotripsy should be performed with pulse rates below 500 Hz and/or increased saline irrigation rates. The TFL rapidly fragmented kidney stones due in part to its high pulse rate, high power density, high average power, and reduced stone retropulsion, and may provide a clinical alternative to the conventional Holmium laser for lithotripsy.

  15. Fiber-optic manipulation of urinary stone phantoms using holmium:YAG and thulium fiber lasers

    NASA Astrophysics Data System (ADS)

    Blackmon, Richard L.; Case, Jason R.; Trammell, Susan R.; Irby, Pierce B.; Fried, Nathaniel M.

    2013-02-01

    Fiber-optic attraction of urinary stones during laser lithotripsy may be exploited to manipulate stone fragments inside the urinary tract without mechanical grasping tools, saving the urologist time and space in the ureteroscope working channel. We compare thulium fiber laser (TFL) high pulse rate/low pulse energy operation to conventional holmium:YAG low pulse rate/high pulse energy operation for fiber-optic suctioning of plaster-of-paris (PoP) stone phantoms. A TFL (wavelength of 1908 nm, pulse energy of 35 mJ, pulse duration of 500 μs, and pulse rate of 10 to 350 Hz) and a holmium laser (wavelength of 2120 nm, pulse energy of 35 to 360 mJ, pulse duration of 300 μs, and pulse rate of 20 Hz) were tested using 270-μm-core optical fibers. A peak drag speed of ˜2.5 mm/s was measured for both TFL (35 mJ and 150 to 250 Hz) and holmium laser (210 mJ and 20 Hz). Particle image velocimetry and thermal imaging were used to track water flow for all parameters. Fiber-optic suctioning of urinary stone phantoms is feasible. TFL operation at high pulse rates/low pulse energies is preferable to holmium operation at low pulse rates/high pulse energies for rapid and smooth stone pulling. With further development, this novel technique may be useful for manipulating stone fragments in the urinary tract.

  16. Retrograde endopyelotomy: a comparison between laser and Acucise balloon cutting catheter.

    PubMed

    el-Nahas, Ahmed R

    2007-03-01

    Endopyelotomy and laparoscopic pyeloplasty are the preferred modalities for treatment of ureteropelvic junction obstruction because of their minimally invasive nature. There are continuous efforts for improving endopyelotomy techniques and outcome. Retrograde access represents the natural evolution of endopyelotomy. The Acucise cutting balloon catheter (Applied Medical Resources Corp., Laguna Hills, CA) and ureteroscopic endopyelotomy using holmium laser are the most widely accepted techniques. The Acucise catheter was developed to simplify retrograde endopyelotomy and made it possible for all urologists, regardless of their endourologic skills. The Acucise catheter depends on incision and dilatation of the ureteropelvic junction under fluoroscopic guidance, whereas ureteroscopy allows visual control of the site, depth, and extent of the incision; the holmium laser is a perfect method for a clean precise incision. Review of the English literature showed that the Acucise technique was more widely performed, though laser had better (but not statistically significant) safety and efficacy profiles.

  17. Thulium fiber laser lithotripsy in an in vitro ureter model

    NASA Astrophysics Data System (ADS)

    Hardy, Luke A.; Wilson, Christopher R.; Irby, Pierce B.; Fried, Nathaniel M.

    2014-12-01

    Using a validated in vitro ureter model for laser lithotripsy, the performance of an experimental thulium fiber laser (TFL) was studied and compared to the clinical gold standard holmium:YAG laser. The holmium laser (λ=2120 nm) was operated with standard parameters of 600 mJ, 350 μs, 6 Hz, and 270-μm-core optical fiber. The TFL (λ=1908 nm) was operated with 35 mJ, 500 μs, 150 to 500 Hz, and a 100-μm-core fiber. Urinary stones (60% calcium oxalate monohydrate/40% calcium phosphate) of uniform mass and diameter (4 to 5 mm) were laser ablated with fibers through a flexible video-ureteroscope under saline irrigation with flow rates of 22.7 and 13.7 ml/min for the TFL and holmium laser, respectively. The temperature 3 mm from the tube's center and 1 mm above the mesh sieve was measured by a thermocouple and recorded throughout each experiment for both lasers. Total laser and operation times were recorded once all stone fragments passed through a 1.5-mm sieve. The holmium laser time measured 167±41 s (n=12). TFL times measured 111±49, 39±11, and 23±4 s, for pulse rates of 150, 300, and 500 Hz, respectively (n=12 each). Mean peak saline irrigation temperatures reached 24±1°C for holmium, and 33±3°C, 33±7°C, and 39±6°C, for TFL at pulse rates of 150, 300, and 500 Hz, respectively. To avoid thermal buildup and provide a sufficient safety margin, TFL lithotripsy should be performed with pulse rates below 500 Hz and/or increased saline irrigation rates. The TFL rapidly fragmented kidney stones due in part to its high pulse rate, high power density, high average power, and observation of reduced stone retropulsion and may provide a clinical alternative to the conventional holmium laser for lithotripsy.

  18. Fiber optic suctioning of urinary stone phantoms during laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Blackmon, Richard L.; Case, Jason R.; Trammell, Susan R.; Irby, Pierce B.; Fried, Nathaniel M.

    2013-03-01

    Fiber optic attraction of urinary stones during laser lithotripsy has been previously observed, and this phenomenon may potentially be exploited to pull stones inside the urinary tract without mechanical grasping tools, thus saving the urologist valuable time and space in the ureteroscope's single working channel. In this study, Thulium fiber laser (TFL) high-pulse-rate/low-pulse-energy operation and Holmium:YAG low-pulse-rate/high-pulse-energy operation are compared for fiber optic "suctioning" of Plaster-of-Paris stone phantoms. A TFL with wavelength of 1908 nm, pulse energy of 35 mJ, pulse duration of 500 μs, and pulse rate of 10-350 Hz, and Holmium laser with wavelength of 2120 nm, pulse energy of 35-360 mJ, pulse duration of 300 μs, and pulse rate of 20 Hz were tested using 270-μm-core fibers. A peak "pull" speed of 2.5 mm/s was measured for both TFL (35 mJ and 150-250 Hz) and Holmium laser (210 mJ and 20 Hz). Particle image velocimetry and thermal imaging were used to track water flow for all parameters. Fiber optic suctioning of urinary stone phantoms is feasible for both lasers. However, TFL operation at high-pulse-rates/low-pulse-energies provides faster, smoother stone pulling than Holmium operation at low-pulserates/ high-pulse-energies. After further study, this method may be used to manipulate urinary stones in the clinic.

  19. Fiber optic muzzle brake tip for reducing fiber burnback and stone retropulsion during thulium fiber laser lithotripsy.

    PubMed

    Hutchens, Thomas C; Gonzalez, David A; Irby, Pierce B; Fried, Nathaniel M

    2017-01-01

    The experimental thulium fiber laser (TFL) is being explored as an alternative to the current clinical gold standard Holmium:YAG laser for lithotripsy. The near single-mode TFL beam allows coupling of higher power into smaller optical fibers than the multimode Holmium laser beam profile, without proximal fiber tip degradation. A smaller fiber is desirable because it provides more space in the ureteroscope working channel for increased saline irrigation rates and allows maximum ureteroscope deflection. However, distal fiber tip burnback increases as fiber diameter decreases. Previous studies utilizing hollow steel sheaths around recessed distal fiber tips reduced fiber burnback but increased stone retropulsion. A “fiber muzzle brake” was tested for reducing both fiber burnback and stone retropulsion by manipulating vapor bubble expansion. TFL lithotripsy studies were performed at 1908 nm, 35 mJ, 500 ?? ? s , and 300 Hz using a 100 - ? m -core fiber. The optimal stainless steel muzzle brake tip tested consisted of a 1-cm-long, 560 - ? m -outer-diameter, 360 - ? m -inner-diameter tube with a 275 - ? m -diameter through hole located 250 ?? ? m from the distal end. The fiber tip was recessed a distance of 500 ?? ? m . Stone phantom retropulsion, fiber tip burnback, and calcium oxalate stone ablation studies were performed ex vivo. Small stones with a mass of 40 ± 4 ?? mg and 4-mm-diameter were ablated over a 1.5-mm sieve in 25 ± 4 ?? s

  20. Minimally invasive management with holmium laser in total urinary tract calculi.

    PubMed

    Zhang, Xiao; Yu, Jianjun; Yang, Ranxing

    2013-05-01

    The purpose of this article was to study the management of total urinary tract calculi using holmium laser minimally invasive techniques. It is rare for patients to present kidney stones, ureteral stones, and bladder stones simultaneously, and their treatment is considered to be complicated and difficult, specifically by minimally invasive techniques. We collected seven cases of total urinary tract calculi from May 2007 to September 2012. Three cases were unilateral, and the others were bilateral. All of the cases presented calculus in the bladder, ureter, and kidney, which were secondary to the long-term indwelling double J stent or lower urinary obstruction. Extracorporeal shock-wave lithotripsy (SWL) was administered first, followed by the operation. For patients with bilateral calculi, at one stage, ureteroscopic lithotripsy (URL) with holmium laser was performed in all four cases to remove the bladder and bilateral ureter stones. Then, all patients underwent percutaneous nephrolithotomy (PCNL) with holmium procedures to address the bilateral kidney and upper ureter stones at the second stage. The indwelling double J stents were removed at the same time. For the patients with unilateral calculi, we performed a single operation, but it was conducted using the same treatment sequence as the bilateral procedure. The related symptoms in all cases disappeared after the operation. Re-examination showed that the stones were nearly dissolved and that renal function was recovered. URL with holmium laser for the bladder and ureters combined with PCNL to dissolve kidney and upper ureteral stones could be the ideal choice for the treatment of total urinary tract calculi.

  1. Thulium fiber laser lithotripsy using a muzzle brake fiber tip

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas C.; Gonzalez, David A.; Irby, Pierce B.; Fried, Nathaniel M.

    2017-02-01

    The Thulium fiber laser (TFL) is being explored as an alternative to Holmium:YAG laser for lithotripsy. TFL beam profile allows coupling of higher power into smaller fibers than multimode Holmium laser beam, without proximal fiber tip degradation. A smaller fiber provides more space in ureteroscope working channel for increased saline irrigation and allows maximum ureteroscope flexion. However, distal fiber tip burnback increases as fiber diameter decreases. Previous studies utilizing hollow steel sheaths around recessed distal fiber tips reduced fiber burnback, but increased retropulsion. In this study, a "fiber muzzle brake" was tested for reducing fiber burnback and stone retropulsion. TFL lithotripsy studies were performed at 1908 nm, 35 mJ, 500 μs, and 300 Hz using a 100-μm-core fiber. The optimal stainless steel muzzle brake tip tested consisted of a 1-cm-long, 560-μm-OD, 360-μm-ID tube with 275-μm thru hole located 250-μm from the distal end. The fiber tip was recessed a distance of 500 μm. Stone phantom retropulsion, fiber tip burnback, and calcium oxalate stone ablation studies were performed, ex vivo. Small stones with a mass of 40 +/- 4 mg and 4-mm-diameter were ablated over a 1.5-mm sieve in 25 +/- 4 s (n=10), without distal fiber tip burnback. Reduction in stone phantom retropulsion distance by 50% and 85% was observed when using muzzle brake tips versus 100-μm-core bare fibers and hollow steel tip fibers. The muzzle brake fiber tip provided efficient stone ablation, reduced stone retropulsion, and minimal fiber degradation during TFL lithotripsy.

  2. Percutaneous endoscopic holmium laser lithotripsy for management of complicated biliary calculi.

    PubMed

    Healy, Kelly; Chamsuddin, Abbas; Spivey, James; Martin, Louis; Nieh, Peter; Ogan, Kenneth

    2009-01-01

    Advances in endoscopic techniques have transformed the management of urolithiasis. We sought to evaluate the role of such urological interventions for the treatment of complex biliary calculi. We conducted a retrospective review of all patients (n=9) undergoing percutaneous holmium laser lithotripsy for complicated biliary calculi over a 4-year period (12/2003 to 12/2007). All previously failed standard techniques include ERCP with sphincterotomy (n=6), PTHC (n=7), or both of these. Access to the biliary system was obtained via an existing percutaneous transhepatic catheter or T-tube tracts. Endoscopic holmium laser lithotripsy was performed via a flexible cystoscope or ureteroscope. Stone clearance was confirmed intra- and post-operatively. A percutaneous transhepatic drain was left indwelling for follow-up imaging. Mean patient age was 65.6 years (range, 38 to 92). Total stone burden ranged from 1.7 cm to 5 cm. All 9 patients had stones located in the CBD, with 2 patients also having additional stones within the hepatic ducts. All 9 patients (100%) were visually stone-free after one endoscopic procedure. No major perioperative complications occurred. Mean length of stay was 2.4 days. At a mean radiological follow-up of 5.4 months (range, 0.5 to 21), no stone recurrence was noted. Percutaneous endoscopic holmium laser lithotripsy is a minimally invasive alternative to open salvage surgery for complex biliary calculi refractory to standard approaches. This treatment is both safe and efficacious. Success depends on a multidisciplinary approach.

  3. Percutaneous Endoscopic Holmium Laser Lithotripsy for Management of Complicated Biliary Calculi

    PubMed Central

    Healy, Kelly; Chamsuddin, Abbas; Spivey, James; Martin, Louis; Nieh, Peter

    2009-01-01

    Background and Objectives: Advances in endoscopic techniques have transformed the management of urolithiasis. We sought to evaluate the role of such urological interventions for the treatment of complex biliary calculi. Methods: We conducted a retrospective review of all patients (n=9) undergoing percutaneous holmium laser lithotripsy for complicated biliary calculi over a 4-year period (12/2003 to 12/2007). All previously failed standard techniques include ERCP with sphincterotomy (n=6), PTHC (n=7), or both of these. Access to the biliary system was obtained via an existing percutaneous transhepatic catheter or T-tube tracts. Endoscopic holmium laser lithotripsy was performed via a flexible cystoscope or ureteroscope. Stone clearance was confirmed intra- and postoperatively. A percutaneous transhepatic drain was left indwelling for follow-up imaging. Results: Mean patient age was 65.6 years (range, 38 to 92). Total stone burden ranged from 1.7 cm to 5 cm. All 9 patients had stones located in the CBD, with 2 patients also having additional stones within the hepatic ducts. All 9 patients (100%) were visually stone-free after one endoscopic procedure. No major perioperative complications occurred. Mean length of stay was 2.4 days. At a mean radiological follow-up of 5.4 months (range, 0.5 to 21), no stone recurrence was noted. Conclusions: Percutaneous endoscopic holmium laser lithotripsy is a minimally invasive alternative to open salvage surgery for complex biliary calculi refractory to standard approaches. This treatment is both safe and efficacious. Success depends on a multidisciplinary approach. PMID:19660213

  4. Performance and safety of holmium: YAG laser optical fibers.

    PubMed

    Knudsen, Bodo E; Glickman, Randolph D; Stallman, Kenneth J; Maswadi, Saher; Chew, Ben H; Beiko, Darren T; Denstedt, John D; Teichman, Joel M H

    2005-11-01

    Lower-pole ureteronephroscopy requires transmission of holmium:YAG energy along a deflected fiber. Current ureteroscopes are capable of high degrees of deflection, which may stress laser fibers beyond safe limits during lower-pole use. We hypothesized that optical fiber and safety measures differ among manufacturers. Small (200-273-microm) and medium-diameter (300-400-microm) Ho:YAG fibers were tested in a straight and 180 degrees bent configuration. Energy transmission was measured by an energy detector. Fiber durability was assessed by firing the laser in sequentially tighter bending diameters. The fibers were bent to 180 degrees with a diameter of 6 cm and run at 200- to 4000-mJ pulse energy to determine the minimum energy required to fracture the fiber. The bending diameter was decreased by 1-cm increments and testing repeated until a bending diameter of 1 cm was reached. The maximum deflection of the ACMI DUR-8E ureteroscope with each fiber in the working channel was recorded. The flow rate through the working channel of the DUR-8E was measured for each fiber. The mean energy transmission differed among fibers (P < 0.001). The Lumenis SL 200 and the InnovaQuartz 400 were the best small and medium-diameter fibers, respectively, in resisting thermal breakdown (P < 0.01). The Dornier Lightguide Super 200 fractured repeatedly at a bend diameter of 2 cm and with the lowest energy (200 mJ). The other small fibers fractured only at a bend diameter of 1 cm. The Sharplan 200 and InnovaQuartz Sureflex 273T were the most flexible fibers, the Lumenis SL 365 the least. The flow rate was inversely proportional to four times the power of the diameter of the fiber. Optical performance and safety differ among fibers. Fibers transmit various amounts of energy to their cladding when bent. During lower-pole nephroscopy with the fiber deflected, there is a risk of fiber fracture from thermal breakdown and laser-energy transmission to the endoscope. Some available laser fibers carry a risk of ureteroscope damage.

  5. Stone Attenuation Values Measured by Average Hounsfield Units and Stone Volume as Predictors of Total Laser Energy Required During Ureteroscopic Lithotripsy Using Holmium:Yttrium-Aluminum-Garnet Lasers.

    PubMed

    Ofude, Mitsuo; Shima, Takashi; Yotsuyanagi, Satoshi; Ikeda, Daisuke

    2017-04-01

    To evaluate the predictors of the total laser energy (TLE) required during ureteroscopic lithotripsy (URS) using the holmium:yttrium-aluminum-garnet (Ho:YAG) laser for a single ureteral stone. We retrospectively analyzed the data of 93 URS procedures performed for a single ureteral stone in our institution from November 2011 to September 2015. We evaluated the association between TLE and preoperative clinical data, such as age, sex, body mass index, and noncontrast computed tomographic findings, including stone laterality, location, maximum diameter, volume, stone attenuation values measured using average Hounsfield units (HUs), and presence of secondary signs (severe hydronephrosis, tissue rim sign, and perinephric stranding). The mean maximum stone diameter, volume, and average HUs were 9.2 ± 3.8 mm, 283.2 ± 341.4 mm 3 , and 863 ± 297, respectively. The mean TLE and operative time were 2.93 ± 3.27 kJ and 59.1 ± 28.1 minutes, respectively. Maximum stone diameter, volume, average HUs, severe hydronephrosis, and tissue rim sign were significantly correlated with TLE (Spearman's rho analysis). Stepwise multiple linear regression analysis defining stone volume, average HUs, severe hydronephrosis, and tissue rim sign as explanatory variables showed that stone volume and average HUs were significant predictors of TLE (standardized coefficients of 0.565 and 0.320, respectively; adjusted R 2  = 0.55, F = 54.7, P <.001). Stone attenuation values measured by average HUs and stone volume were strong predictors of TLE during URS using Ho:YAG laser procedures. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Comparison of the Nanopulse Lithotripter to the Holmium Laser: Stone Fragmentation Efficiency and Impact on Flexible Ureteroscope Deflection and Flow.

    PubMed

    Kaplan, Adam G; Chen, Tony T; Sankin, Georgy; Yang, Chen; Dale, Joanne A; Simmons, W Neal; Zhong, Pei; Preminger, Glenn M; Lipkin, Michael Eric

    2016-11-01

    The Nanopulse Lithotripter (NPL; Lithotech Medical, Israel) is a novel intracorporeal device that uses a nanosecond duration electrical discharge through a reusable flexible coaxial probe to endoscopically fragment urinary stones. This device was compared with a holmium laser lithotripsy (HoL) with regard to stone fragmentation efficiency (SFE) and its impact on flexible ureteroscope (URS) deflection and flow of irrigation. Using a custom bench model, a 6 mm BegoStone cylindrical phantom (mixture 5:2) was confined under 0.9% saline atop sequential mesh sieves. The SFE of two NPL probe sizes (2.0F, 3.6F) and two HoL fibers (200, 365 μm) was evaluated using concordant settings of 1 J and 5 Hz. URS deflection and irrigation flow with NPL probes in the working channel were tested in five new fourth generation flexible URS and compared with other adjunct endourologic instruments. The 2.0F NPL showed improved SFE compared with the 200 μm laser (86 mg/min vs 52 mg/min, p = 0.014) as did the 3.6F NPL vs the 365 μm laser (173 mg/min vs 80 mg/min, p = 0.05). The NPL created more 1 to 2 mm fragments; the laser created more dust. URS deflection reduced by 3.75° with the 2.0 NPL probe. URS irrigation flow reduced from 36.5 to 6.3 mL/min with the 2.0F NPL probe. NPL shows improved SFE compared with HoL. Flow with the 2.0F probe is akin to a stone basket. NPL offers an effective alternative to HoL.

  7. Combined electrohydraulic and holmium: YAG laser ureteroscopic nephrolithotripsy of large (>2 cm) renal calculi

    PubMed Central

    Mariani, Albert J.

    2008-01-01

    Percutaneous nephrolithotripsy (PCL) is a standard treatment for renal calculi >2 cm. Modern flexible ureteroscopes and accessories employing the complementary effects of electrohydraulic lithotripsy (EHL) and Ho:YAG laser lithotrites can treat these renal calculi in a minimally invasive fashion with similar or superior results. Objective: To assess the safety and efficacy of ureteroscopic nephrolithotripsy monotherapy for the management of >2 cm renal calculi in the community setting. Materials and Methods: Fifty nine patients with 63 renal calculi ranging from 20 to 97 mm (mean 44 mm) in length and 175 to 3300 mm2 (mean 728 mm2) area underwent staged ureteroscopic nephrolithotripsy monotherapy. Obesity (BMI > 30) was present in 54% and 19% were morbidly obese (BMI > 40). An infectious etiology was present in 49% and hard stone components in 89%. All patients presented with hematuria, pain, and/or recurrent urinary tract infection (UTI). Lithotripsy was performed with a single deflection flexible ureteroscope and predominantly EHL. Laser drilling was employed (n = 6) to weaken very hard stones prior to EHL. Low intrarenal pressure was maintained by continuous bladder drainage and placement of a stiff safety wire. Visibility was maintained using manual pulsatile irrigation. Results: All patients were rendered pain and infection-free. No patient required a blood transfusion and there was no change in serum creatinine. Mobile stone-free status was achieved in 60/63 (95%) with a mean of 1.7 nephrolithotripsy stages and 0.38 secondary or ancillary procedures. Outpatient management was sufficient for 121/131 (92%) of the procedures. Operative time averaged 46 min/stage and 79 min/calculus. Complications included endotoxic shock (3), fever (5), ureteral fragments requiring treatment (11), delayed extubation (2), delayed pneumonia (1), and urinary retention (1). Conclusion: Staged ureteroscopic nephrolithotripsy of large renal calculi is feasible with low morbidity and stone clearance rates that compare favorably with PCL. It has largely replaced PCL at this institution. PMID:19468511

  8. Use of the Escape nitinol stone retrieval basket facilitates fragmentation and extraction of ureteral and renal calculi: a pilot study.

    PubMed

    Kesler, Stuart S; Pierre, Sean A; Brison, Daniel I; Preminger, Glenn M; Munver, Ravi

    2008-06-01

    Advances in ureteroscope and stone basket design have catapulted ureteroscopy to the forefront of surgical stone management; however, persistent problems such as stone migration continue to challenge urologists. The Escape nitinol stone retrieval basket (Boston Scientific, Natick, MA) is a stone basket designed to capture calculi and facilitate simultaneous laser lithotripsy in situ. We report our initial experience with the Escape basket for the management of urinary calculi and compare the use of this device with other methods of optimizing ureteroscopic stone management. A prospective evaluation of 23 patients undergoing ureteroscopic holmium:yttrium-aluminum-garnet laser lithotripsy of urinary calculi was performed at two institutions by two surgeons (R.M. and G.M.P). The Escape basket was used to prevent retrograde ureteral stone migration or to facilitate fragmentation and extraction of large renal calculi. Patient demographics and perioperative parameters were assessed. Twenty-three patients (16 men, 7 women), with a mean age of 55.5 years (range 33-74 yrs) were treated for renal (n = 9) or ureteral (n = 14) calculi. The mean stone diameter was 1.4 cm (range 0.4-2.5 cm), mean fragmentation time was 44.1 minutes (range 10-75 min), and mean energy used was 3.1 kJ (range 0.4-10.6 kJ). No complications were encountered. Eighty-seven percent (20/23) of patients were rendered completely stone free after ureteroscopic laser lithotripsy using the Escape basket. Of the three patients with residual calculi, one patient with a 2.5-cm renal calculus had residual fragments larger than 3 mm, and two patients with large renal calculi had residual fragments smaller than 3 mm. The Escape basket appears to be safe and effective in preventing stone migration and facilitating ureteroscopic laser lithotripsy and stone extraction.

  9. Treatment of ureteric calculi--use of Holmium: YAG laser lithotripsy versus pneumatic lithoclast.

    PubMed

    Tipu, Salman Ahmed; Malik, Hammad Afzal; Mohhayuddin, Nazim; Sultan, Gauhar; Hussain, Manzoor; Hashmi, Altaf; Naqvi, Syed Ali Anwar; Rizvi, Syed Adibul Hasan

    2007-09-01

    To compare the efficacy of Holmium: YAG laser and pneumatic lithoclast in treating ureteric calculi. The study included total of 100 patients divided into two equal groups of laser lithotripsy (LL) and pneumatic lithoclast (PL). Study was conducted between September 2006 and February 2007. Inclusion criteria were patients with a ureteric stone of size 1-2 cm and negative urine culture. An x-ray KUB was mandatory. IVU and CT pyelogram were also done when required. Procedures were done under general anaesthesia after a single dose of pre-operative antibiotic. A 7.5 Fr semi rigid ureteroscope was used for ureteroscopy in all cases. Holmium: YAG laser with 365 microm wide probe was employed in laser group and frequency was set between 5 and 10 Hz at a power of 10 to 15 W. Swiss lithoclast with single or multiple fire technique was used accordingly in PL group. Postoperatively patients underwent radiography and helical CT as required at 4th week of follow up to asses stone clearance. The mean patient age in LL and PL group was 38 +/- 10 and 40 +/- 10 years respectively. The male to female ratio and stone size were similar between the groups. Stone migration up in pelvicalyceal system occurred in two patients of LL group while in eight patients of PL group. JJ Stent was placed in 5(10%) patients in laser group where as 13 (26%) patients required it in pneumatic lithoclast group. Stone free rate at 4 weeks was 92% in laser group as compared to 82% in pneumatic lithoclast group. Hospital stay was more than 24 hours in 2 patients of laser group as compared to 5 patients of pneumatic lithoclast group. Complication rate was 4% in LL group whereas it was 14% in PL group. Holmium: YAG laser lithotripsy is a superior technology compared to pneumatic lithoclast in terms of rate of stone clearance and complications, especially in upper ureteric stones.

  10. Management of upper urinary tract calculi with ureteroscopic techniques.

    PubMed

    Tawfiek, E R; Bagley, D H

    1999-01-01

    To evaluate our experience in treating 155 patients with upper urinary tract calculi ureteroscopically. The treatment of urinary calculi has remained the most frequent application of ureteroscopy. Miniaturization of semirigid and flexible ureteroscopes has permitted easier access to calculi throughout the urinary tract. Ureteroscopic stone treatment was attempted in 155 patients with upper urinary tract calculi between November 1995 and March 1997. Fifty-nine (38.1%) patients had renal calculi, 82 (52.9%) ureteral, and 14 (9%) had both renal and ureteral calculi. Both semirigid and flexible ureteroscopes were used for treatment (rigid alone in 21 [13.5%], flexible in 64 [41.3%], and both rigid and flexible in 70 [45.2%] patients). Lithotripsy was required in 122 (79%) of the patients. The holmium:yttrium-aluminum-garnet laser was used in 113 (92.6%) of these patients. All patients with ureteral calculi (29 proximal, 19 mid, and 34 distal) were successfully cleared after one endoscopic procedure except for 1 patient with a proximal ureteral calculus who had a 4-mm residual fragment in the kidney. Of the 59 patients with renal calculi, 47 (79.7%) were totally clear of stones 1 month after treatment. The remaining 12 (20.3%) patients had evidence of residual calculi 3 to 4 mm or less in diameter. In patients with combined renal and ureteral calculi, 1 1 of 14 (78.6%) were rendered stone free. The remaining 3 (21.4%) patients had evidence of residual calculi 4 mm in diameter. Overall, 95% of the patients were treated in an outpatient setting. Morbidity was low, with no evidence of stricture. Ureteroscopy and laser lithotripsy in experienced hands are a safe and reliable method for the treatment of ureteral and even intrarenal calculi.

  11. Miniature ball-tip optical fibers for use in thulium fiber laser ablation of kidney stones

    NASA Astrophysics Data System (ADS)

    Wilson, Christopher R.; Hardy, Luke A.; Kennedy, Joshua D.; Irby, Pierce B.; Fried, Nathaniel M.

    2016-01-01

    Optical fibers, consisting of 240-μm-core trunk fibers with rounded, 450-μm-diameter ball tips, are currently used during Holmium:YAG laser lithotripsy to reduce mechanical damage to the inner lining of the ureteroscope working channel during fiber insertion and prolong ureteroscope lifetime. Similarly, this study tests a smaller, 100-μm-core fiber with 300-μm-diameter ball tip during thulium fiber laser (TFL) lithotripsy. TFL was operated at a wavelength of 1908 nm, with 35-mJ pulse energy, 500-μs pulse duration, and 300-Hz pulse rate. Calcium oxalate/phosphate stone samples were weighed, laser procedure times were measured, and ablation rates were calculated for ball tip fibers, with comparison to bare tip fibers. Photographs of ball tips were taken before and after each procedure to track ball tip degradation and determine number of procedures completed before need for replacement. A high speed camera also recorded the cavitation bubble dynamics during TFL lithotripsy. Additionally, saline irrigation rates and ureteroscope deflection were measured with and without the presence of TFL fiber. There was no statistical difference (P>0.05) between stone ablation rates for single-use ball tip fiber (1.3±0.4 mg/s) (n=10), multiple-use ball tip fiber (1.3±0.5 mg/s) (n=44), and conventional single-use bare tip fibers (1.3±0.2 mg/s) (n=10). Ball tip durability varied widely, but fibers averaged greater than four stone procedures before failure, defined by rapid decline in stone ablation rates. Mechanical damage at the front surface of the ball tip was the limiting factor in fiber lifetime. The small fiber diameter did not significantly impact ureteroscope deflection or saline flow rates. The miniature ball tip fiber may provide a cost-effective design for safe fiber insertion through the ureteroscope working channel and into the ureter without risk of instrument damage or tissue perforation, and without compromising stone ablation efficiency during TFL lithotripsy.

  12. Fiber optic muzzle brake tip for reducing fiber burnback and stone retropulsion during thulium fiber laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas C.; Gonzalez, David A.; Irby, Pierce B.; Fried, Nathaniel M.

    2017-01-01

    The experimental thulium fiber laser (TFL) is being explored as an alternative to the current clinical gold standard Holmium:YAG laser for lithotripsy. The near single-mode TFL beam allows coupling of higher power into smaller optical fibers than the multimode Holmium laser beam profile, without proximal fiber tip degradation. A smaller fiber is desirable because it provides more space in the ureteroscope working channel for increased saline irrigation rates and allows maximum ureteroscope deflection. However, distal fiber tip burnback increases as fiber diameter decreases. Previous studies utilizing hollow steel sheaths around recessed distal fiber tips reduced fiber burnback but increased stone retropulsion. A "fiber muzzle brake" was tested for reducing both fiber burnback and stone retropulsion by manipulating vapor bubble expansion. TFL lithotripsy studies were performed at 1908 nm, 35 mJ, 500 μs, and 300 Hz using a 100-μm-core fiber. The optimal stainless steel muzzle brake tip tested consisted of a 1-cm-long, 560-μm-outer-diameter, 360-μm-inner-diameter tube with a 275-μm-diameter through hole located 250 μm from the distal end. The fiber tip was recessed a distance of 500 μm. Stone phantom retropulsion, fiber tip burnback, and calcium oxalate stone ablation studies were performed ex vivo. Small stones with a mass of 40±4 mg and 4-mm-diameter were ablated over a 1.5-mm sieve in 25±4 s (n=10) without visible distal fiber tip burnback. Reduction in stone phantom retropulsion distance by 50% and 85% was observed when using muzzle brake tips versus 100-μm-core bare fibers and hollow steel tip fibers, respectively. The muzzle brake fiber tip simultaneously provided efficient stone ablation, reduced stone retropulsion, and minimal fiber degradation during TFL lithotripsy.

  13. Fluid Dynamic Analysis of Hand-Pump Infuser and UROMAT Endoscopic Automatic System for Irrigation Through a Flexible Ureteroscope.

    PubMed

    Lama, Daniel J; Owyong, Michael; Parkhomenko, Egor; Patel, Roshan M; Landman, Jaime; Clayman, Ralph V

    2018-05-01

    To evaluate the flow characteristics produced by a manual and automated-pump irrigation system connected to a flexible ureteroscope. An in vitro analysis of a manual hand-pump infuser (HP) and the UROMAT Endoscopic Automatic System for Irrigation ® (E.A.S.I.) pump was performed. Standard irrigation tubing was used to connect a three-way valve to a flexible ureteroscope, the irrigation system, and a digital manometer. Flow rate and irrigation pressure measurements were recorded over a 15-minute period using pressure settings of 150 and 200 mm Hg for both irrigation pump systems. Once the HP was inflated to the initial pressure, it was not reinflated over the course of the trial. Data were collected with the working channel unoccupied and with placement of a 200 μm (0.6F) holmium laser fiber, 1.7F nitinol stone retrieval basket, or 2.67F guidewire. The difference in pressure measured at the site of inflow of irrigation to the ureteroscope was significantly greater using the HP compared to the E.A.S.I. pump at pressure settings of 150 mm Hg with and without the use of ureteroscopic instrumentation (p < 0.001), and at 200 mm Hg with instrumentation in the working channel (p < 0.01). There was no significant difference in the flow rate of irrigation through the open-channel ureteroscope over the course of 5 minutes between the two pump systems. The flow rates of irrigation produced by the HP and the E.A.S.I. pump are similar at pressures of 150 and 200 mm Hg irrespective of the occupancy of a ureteroscope's working channel during the first 5-minutes of irrigation. Irrigation pressure at the entry site of the ureteroscope is subject to significant variability with use of the HP compared to the E.A.S.I. pump irrigation system.

  14. Integrated and miniaturized endoscopic devices for use during high power infrared fiber laser surgery

    NASA Astrophysics Data System (ADS)

    Wilson, Christopher Ryan

    The Thulium Fiber Laser (TFL) is currently being studied as a potential alternative to the conventional, solid-state Holmium:YAG laser (Ho:YAG) for the treatment of kidney stones. The TFL is an ideal candidate to replace the Ho:YAG for laser lithotripsy due to a higher absorption coefficient in water of the emitted wavelength, an ability to operate at high pulse rates, and a near single mode, Gaussian spatial beam profile. The higher absorption of the TFL wavelength by water translates to a decrease in ablation threshold by a factor of four. High pulse rate operation allows higher ablation rates than the Ho:YAG, thus decreasing operation time necessary to ablate the urinary stone. The Gaussian spatial beam profile allows the TFL to couple higher laser power into smaller optical fibers than those currently being used for Ho:YAG lithotripsy. This decrease in fiber diameter translates into a potential decrease in the size of ureteroscope working channel, higher saline irrigation rates for improved visibility and safety, and may also extend to a decrease in overall ureteroscope diameter. Furthermore, the improved spatial beam profile reduces the risk of damage to the input end of the fiber. Therefore, the trunk fiber, minus the distal fiber tip, may be preserved and re-used, resulting in significant cost savings. This thesis details rapid TFL lithotripsy at high pulse rates up to 500 Hz, both with and without the aid of a stone retrieval basket, in order to demonstrate the TFL's superior ablation rates over the Ho:YAG. Collateral damage testing of the TFL effect on the ureter wall and Nitinol stone baskets were conducted to ensure patient safety for future clinical use. Proximal fiber end damage testing was conducted to demonstrate fiber preservation, critical for permanent fiber integration. Optical fibers were fitted with fabricated hollow steel tips and integrated with stone retrieval baskets for testing. Ball tipped optical fibers were tested to maintain ablation rates comparable to those of the 100-mum-core traditional fiber used in TFL lithotripsy while providing an additional safety feature for initial fiber insertion through the ureteroscope working channel. Working channel flow rates were explored in regards to diameter and geometry. Illumination sources and configurations were explored in regards to optimized wavelength selection as well as physical geometry of the ureteroscope tip. Ureteroscope designs were devised, modeled, fabricated, and tested, implementing a reduced working channel, and optimized illumination geometry, culminating in an integrated, miniaturized ureteroscope for use in TFL lithotripsy. This final device, coupled with the proven TFL and optimized laser parameters may establish the TFL as a viable replacement to the conventional Ho:YAG laser for treatment of kidney stones.

  15. Retrograde Ureteroscopic Management of Large Renal Calculi: A Single Institutional Experience and Concise Literature Review.

    PubMed

    Scotland, Kymora B; Rudnick, Benjamin; Healy, Kelly A; Hubosky, Scott G; Bagley, Demetrius H

    2018-06-06

    Advances in flexible ureteroscope design and accessory instrumentation have allowed for more challenging cases to be treated ureteroscopically. Here, we evaluate our experience with ureteroscopy (URS) for the management of large renal calculi (≥2 cm) and provide a concise review of recent reports. A retrospective review was undertaken of all URS cases between 2004 and 2014 performed by the endourologic team at a single academic tertiary care institution. We identified patients with at least one stone ≥2 cm managed with retrograde URS. Stone size was defined as the largest linear diameter of the index stone. Small diameter flexible ureteroscopes were used primarily with holmium laser. Patient demographics, intraoperative data, and postoperative outcomes were evaluated. We evaluated 167 consecutive patients who underwent URS for large renal stones ≥2 cm. The initial reason for choosing URS included patient preference (29.5%), failure of other therapies (8.2%), anatomic considerations/body habitus (30.3%), and comorbidities (28.8%). Mean patient age was 55.5 years (22-84). The mean stone size was 2.75 cm with mean number of procedures per patient of 1.65 (1-6). The single session stone-free rate was 57.1%, two-stage procedure stone-free rate was 90.2% and three-stage stone-free rate was 94.0%. Access sheaths were used in 47% of patients. An association was identified between stone size and patient outcomes; smaller stones correlated with decreased number of procedures. Postoperative complications were minor. Single or multi-stage retrograde ureteroscopic lithotripsy is a safe and effective mode of surgical management of large renal calculi. Total stone burden is a reliable predictor of the need for a staged procedure and of stone-free rate.

  16. Percutaneous Transhepatic Endoscopic Holmium Laser Lithotripsy for Intrahepatic and Choledochal Biliary Stones

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Kleinmann, Nir; Bensaid, Paul

    2011-12-15

    Purpose: To report our approach for treating complicated biliary calculi by percutaneous transhepatic endoscopic biliary holmium laser lithotripsy (PTBL). Patients and Methods: Twenty-two symptomatic patients (11 men and 11 women, age range 51 to 88 years) with intrahepatic or common bile duct calculi underwent PTBL. Nine patients had undergone previous gastrectomy and small-bowel anastomosis, thus precluding endoscopic retrograde cholangiopancreatography. In the other 13 patients, stone removal attempts by ERCP failed due to failed access or very large calculi. We used a 7.5F flexible ureteroscope and a 200-{mu}m holmium laser fiber by way of a percutaneous transhepatic tract, with graded fluoroscopy,more » to fragment the calculi with direct vision. Balloon dilatation was added when a stricture was seen. The procedure was performed with the patient under general anaesthesia. A biliary drainage tube was left at the end of the procedure. Results: All stones were completely fragmented and flushed into the small bowel under direct vision except for one patient in whom the procedure was aborted. In 18 patients, 1 session sufficed, and in 3 patients, 2 sessions were needed. In 7 patients, balloon dilatation was performed for benign stricture after Whipple operation (n = 3), for choledochalenteric anastomosis (n = 3), and for recurrent cholangitis (n = 1). Adjunctive 'balloon push' (n = 4) and 'rendezvous' (n = 1) procedures were needed to completely clean the biliary tree. None of these patients needed surgery. Conclusion: Complicated or large biliary calculi can be treated successfully using PTBL. We suggest that this approach should become the first choice of treatment before laparoscopic or open surgery is considered.« less

  17. Flexible ureteroscopic lithotripsy for the treatment of upper urinary tract calculi in infants

    PubMed Central

    Li, Jun; Han, Tiandong; Tian, Ye; Wang, Wenying; Du, Yuan

    2016-01-01

    We evaluated the clinical value of flexible ureteroscopic lithotripsy for the treatment of upper urinary tract calculi in infants. Fifty-five infants with upper urinary tract calculi were included in this study: 41 males and 14 females. Retrograde intrarenal surgery was performed by an 8 Fr/30 cm flexible ureterorenoscope (POLY®) combined with a holmium laser. CT scanning or radiography of the kidneys, ureters, and bladder region was performed one month after the operation to confirm the clearance of calculi. All the 55 infants with calculi in 74 sides underwent 66 flexible ureteroscopic lithotripsy procedures. The median operation time was 30 min. The median amount of flushing fluid was 500 mL. The stone-free rate after a single session treatment was 94.6%, within which 10 infants underwent simultaneous bilateral flexible ureteroscopy lithotripsy. Catheters were retained in 45 infants for 24–48 h after the operation. Continuous high fever due to reflux was present in two cases. Flushing fluid extravasation was found in one infant. Some patients with minor complications, such as mild hematuria, irritation symptoms, and low fever, recovered without treatment. The duration of hospitalization time after the operation was approximately 1–5 days. Flexible ureteroscopic lithotripsy is a safe, highly efficient, minimally invasive, and reproducible operation for removal of upper urinary tract calculi in infants. This technique is a convenient method for postoperative management of patients that enhances their rapid recovery. It is a promising option for therapy of infants ineffectively treated by extracorporeal shockwave lithotripsy. PMID:27633576

  18. Flexible ureteroscopic lithotripsy for the treatment of upper urinary tract calculi in infants.

    PubMed

    Li, Jun; Xiao, Jing; Han, Tiandong; Tian, Ye; Wang, Wenying; Du, Yuan

    2017-01-01

    We evaluated the clinical value of flexible ureteroscopic lithotripsy for the treatment of upper urinary tract calculi in infants. Fifty-five infants with upper urinary tract calculi were included in this study: 41 males and 14 females. Retrograde intrarenal surgery was performed by an 8 Fr/30 cm flexible ureterorenoscope (POLY®) combined with a holmium laser. CT scanning or radiography of the kidneys, ureters, and bladder region was performed one month after the operation to confirm the clearance of calculi. All the 55 infants with calculi in 74 sides underwent 66 flexible ureteroscopic lithotripsy procedures. The median operation time was 30 min. The median amount of flushing fluid was 500 mL. The stone-free rate after a single session treatment was 94.6%, within which 10 infants underwent simultaneous bilateral flexible ureteroscopy lithotripsy. Catheters were retained in 45 infants for 24-48 h after the operation. Continuous high fever due to reflux was present in two cases. Flushing fluid extravasation was found in one infant. Some patients with minor complications, such as mild hematuria, irritation symptoms, and low fever, recovered without treatment. The duration of hospitalization time after the operation was approximately 1-5 days. Flexible ureteroscopic lithotripsy is a safe, highly efficient, minimally invasive, and reproducible operation for removal of upper urinary tract calculi in infants. This technique is a convenient method for postoperative management of patients that enhances their rapid recovery. It is a promising option for therapy of infants ineffectively treated by extracorporeal shockwave lithotripsy.

  19. Hollow steel tips for reducing distal fiber burn-back during thulium fiber laser lithotripsy.

    PubMed

    Hutchens, Thomas C; Blackmon, Richard L; Irby, Pierce B; Fried, Nathaniel M

    2013-07-01

    The use of thulium fiber laser (TFL) as a potential alternative laser lithotripter to the clinical holmium:YAG laser is being studied. The TFL's Gaussian spatial beam profile provides efficient coupling of higher laser power into smaller core fibers without proximal fiber tip degradation. Smaller fiber diameters are more desirable, because they free up space in the single working channel of the ureteroscope for increased saline irrigation rates and allow maximum ureteroscope deflection. However, distal fiber tip degradation and "burn-back" increase as fiber diameter decreases due to both excessive temperatures and mechanical stress experienced during stone ablation. To eliminate fiber tip burn-back, the distal tip of a 150-μm core silica fiber was glued inside 1-cm-long steel tubing with fiber tip recessed 100, 250, 500, 1000, or 2000 μm inside the steel tubing to create the hollow-tip fiber. TFL pulse energy of 34 mJ with 500-μs pulse duration and 150-Hz pulse rate was delivered through the hollow-tip fibers in contact with human calcium oxalate monohydrate urinary stones during ex vivo studies. Significant fiber tip burn-back and degradation was observed for bare 150-μm core-diameter fibers. However, hollow steel tip fibers experienced minimal fiber burn-back without compromising stone ablation rates. A simple, robust, compact, and inexpensive hollow fiber tip design was characterized for minimizing distal fiber burn-back during the TFL lithotripsy. Although an increase in stone retropulsion was observed, potential integration of the hollow fiber tip into a stone basket may provide rapid stone vaporization, while minimizing retropulsion.

  20. Thulium fiber laser lithotripsy using tapered fibers.

    PubMed

    Blackmon, Richard L; Irby, Pierce B; Fried, Nathaniel M

    2010-01-01

    The Thulium fiber laser has recently been tested as a potential alternative to the Holmium:YAG laser for lithotripsy. This study explores use of a short taper for expanding the Thulium fiber laser beam at the distal tip of a small-core fiber. Thulium fiber laser radiation with a wavelength of 1,908 nm, 10 Hz pulse rate, 70 mJ pulse energy, and 1-millisecond pulse duration was delivered through a 2-m-length fiber with 150-microm-core-input-end, 300-microm-core-output-end, and 5-mm-length taper, in contact with human uric acid (UA) and calcium oxalate monohydrate (COM) stones, ex vivo (n = 10 each). Stone mass loss, stone crater depths, fiber transmission losses, fiber burn-back, irrigation rates, and deflection through a flexible ureteroscope were measured for the tapered fiber and compared with conventional fibers. After delivery of 1,800 pulses through the tapered fiber, mass loss measured 12.7+/-2.6 mg for UA and 7.2+/-0.8 mg COM stones, comparable to conventional 100-microm-core fibers (12.6+/-2.5 mg for UA and 6.8+/-1.7 mg for COM stones). No transmission losses or burn-back occurred for the tapered fiber after 36,000 pulses, while a conventional 150-microm fiber experienced significant tip degradation after only 1,800 pulses. High irrigation rates were measured with the tapered fiber inserted through the working port of a flexible ureteroscope without hindering its deflection, mimicking that of a conventional 150 microm fiber. The short tapered distal fiber tip allows expansion of the laser beam, resulting in decreased fiber tip damage compared to conventional small-core fibers, without compromising fiber bending, stone vaporization efficiency, or irrigation rates.

  1. In Vitro Comparison of Holmium Lasers: Evidence for Shorter Fragmentation Time and Decreased Retropulsion Using a Modern Variable-pulse Laser.

    PubMed

    Bell, John Roger; Penniston, Kristina L; Nakada, Stephen Y

    2017-09-01

    To compare the performance of variable- and fixed-pulse lasers on stone phantoms in vitro. Seven-millimeter stone phantoms were made to simulate calcium oxalate monohydrate stones using BegoStone plus. The in vitro setting was created with a clear polyvinyl chloride tube. For each trial, a stone phantom was placed at the open end of the tubing. The Cook Rhapsody H-30 variable-pulse laser was tested on both long- and short-pulse settings and was compared to the Dornier H-20 fixed-pulse laser; 5 trials were conducted for each trial arm. Fragmentation was accomplished with the use of a flexible ureteroscope and a 273-micron holmium laser fiber using settings of 1 J × 12 Hz. The treatment time (in minute) for complete fragmentation was recorded as was the total retropulsion distance (in centimeter) during treatment. Laser fibers were standardized for all repetitions. The treatment time was significantly shorter with the H-30 vs the H-20 laser (14.3 ± 2.5 vs 33.1 ± 8.9 minutes, P = .008). There was no difference between the treatment times using the long vs short pulse widths of the H-30 laser (14.4 ± 3.4 vs 14.3 ± 1.7 minutes, P = .93). Retropulsion differed by laser type and pulse width, H-30 long pulse (15.8 ± 5.7 cm), H-30 short pulse (54.8 ± 7.1 cm), and H-20 (33.2 ± 12.5 cm) (P <.05). The H-30 laser fragmented stone phantoms in half the time of the H-20 laser regardless of the pulse width. Retropulsion effects differed between the lasers, with the H-30 causing the least retropulsion. Longer pulse widths result in less stone retropulsion. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Optimal Settings for the Noncontact Holmium:YAG Stone Fragmentation Popcorn Technique.

    PubMed

    Emiliani, Esteban; Talso, Michele; Cho, Sung-Yong; Baghdadi, Mohammed; Mahmoud, Sadam; Pinheiro, Hugo; Traxer, Olivier

    2017-09-01

    The purpose of this study was to evaluate the popcorn technique using a wide range of holmium laser settings and fiber sizes in a systematic in vitro assessment. Evaluations were done with 4 artificial stones in a collection tube. A fixed ureteroscope was inserted through a ureteral access sheath to provide constant irrigation flow and the laser was placed 1 mm from the bottom. Combinations of 0.5 to 1.5 J, 10 to 20 and 40 Hz, and long and short pulses were tested for 2 and 4 minutes. We used 273 and 365 μm laser fibers. All tests were repeated 3 times. The stones were weighed before and after the experiments to evaluate the setting efficiency. Significant predictors of a highly efficient technique were assessed. A total of 144 tests were performed. Mean starting weight of the stones was 0.23 gm, which was consistent among the groups. After the experiment the median weight difference was 0.07 gm (range 0.01 to 0.24). When designating a 50% reduction in stone volume as the threshold indicating high efficiency, the significant predictors of an efficient popcorn technique were a long pulse (OR 2.7, 95% CI 1.05-7.15), a longer duration (OR 11.4, 95% CI 3.88-33.29), a small (273 μm) laser fiber (OR 0.23, 95% CI 0.08-0.70) and higher power (W) (OR 1.14, 95% CI 1.09-1.20). Higher energy, a longer pulse, frequencies higher than 10 Hz, a longer duration and a smaller laser fiber predict a popcorn technique that is more efficient at reducing stone volume. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Bilateral Simultaneous Ureteroscopic (BS-URS) Approach in the Management of Bilateral Urolithiasis Is a Safe and Effective Strategy in the Contemporary Era-Evidence from a Systematic Review.

    PubMed

    Geraghty, Robert M; Rai, Bhavan P; Jones, Patrick; Somani, Bhaskar K

    2017-02-01

    Ureteroscopic treatment of urolithiasis has become safer and more effective in the modern era. With a rise in the incidence of bilateral urolithiasis, management dilemma of staged single-side ureteroscopy versus bilateral simultaneous ureteroscopy (BS-URS) is often debatable. This review evaluates the current evidence base for bilateral simultaneous ureteroscopic approach in the modern era. A systematic review was conducted from 1990 to June 2016 including all English language articles reporting on outcomes of BS-URS for urolithiasis. Data was split into two periods: period 1: 2003-2012 and period 2: 2013-2016, and analysed using SPSS version 21. A total of 11 studies (491 patients) were identified from a literature search of 148 studies with mean age of 45 years and a male: female ratio of 2:1 and a mean operative time of 69 min (SD = ±15). The initial and final stone-free rate (SFR) was 87 and 93%, respectively. Post-operative stents were placed in 89% of patients with a mean hospital stay of 1.6 days (SD = ±0.5). Overall, there was a significant negative association between case volume (procedures per month) and complication rate (p = 0.045). Mean hospital stay was significantly longer in period 1 (1.9 days, SD = ±0.5) than period 2 (1.3 days, SD = ±0.3) and complications were also significantly higher in period 1 (47%) compared to period 2 (12%) (p < 0.001). There were six studies examining holmium laser (HL) lithotripsy and three examining pneumatic lithotripsy (PL). There were significantly more complications after PL than HL; however, their SFR was similar. Our review shows that the complication rates and hospital stay are significantly reduced in the contemporary data suggesting an improving trend in outcomes following BS-URS. Simultaneous bilateral ureteroscopic treatment of urolithiasis is safe and effective in the modern era. Safety is increased in centers with increased number of procedures performed and with laser lithotripsy.

  4. Comparison of the clinical efficacy and safety of retroperitoneal laparoscopic ureterolithotomy and ureteroscopic holmium laser lithotripsy in the treatment of obstructive upper ureteral calculi with concurrent urinary tract infections.

    PubMed

    Jiang, Jun-Tao; Li, Wei-Guo; Zhu, Yi-Ping; Sun, Wen-Lan; Zhao, Wei; Ruan, Yuan; Zhong, Chen; Wood, Kristofer; Wei, Hai-Bin; Xia, Shu-Jie; Sun, Xiao-Wen

    2016-07-01

    The aim of this study is to compare the clinical efficacy and safety of retroperitoneal laparoscopic ureterolithotomy (RPLU) and ureteroscopic holmium laser lithotripsy (UHLL) as two minimally invasive procedures in managing obstructive upper ureteral calculi with concurrent urinary tract infections (UTI). The retrospective study included 189 patients who underwent unilateral obstructive upper ureteral stones with concurrent UTI from January 2007 to November 2014 at our institution. Patients received RPLU (81 cases) or UHLL (108 cases). All patients received preoperative anti-infection treatment (indwelling ureteral stent and/or preoperative antibiotics). Collected data, including sex, age, stone size, success rate, operation duration, post-operation hospitalization time, and post-operation complications, were compared. All patients were followed up for more than 6 months after surgeries, and no ureterostenosis occurred. The study included 189 patients, 41 (21.7 %) females and 148 (78.3 %) males with a medium age of 52 years (range 22-81 years). All surgeries were successfully performed without conversion to open surgery. Stone size in the RPLU group was larger than that of the UHLL group (16.1 ± 1.4 vs. 10.4 ± 1.6 mm, P = 0.012). Operative duration (P = 0.009) and hospitalization time (P < 0.001) in the UHLL group were significantly shorter than those in the RPLU group, whereas stone clearance rate was significantly higher in the RPLU group (100 vs. 88.9 %, P = 0.002). Of note, postoperative fever was more common in patients treated with UHLL (15 cases) versus RPLU (4 cases) (13.9 vs. 4.9 %, P = 0.043). Moreover, in the UHLL group, three patients without a preoperative indwelling ureteral stent were complicated with sepsis, which was not seen in RPLU group. In our study, the safety and stone clearance rate of RPLU are better than those of UHLL in the treatment of unilateral upper ureteric calculi with concurrent UTI. Preoperative antibiotics and indwelling ureteral stent may reduce the risk of postoperative infections.

  5. Determinants of holmium:yttrium-aluminum-garnet laser time and energy during ureteroscopic laser lithotripsy.

    PubMed

    Molina, Wilson R; Marchini, Giovanni S; Pompeo, Alexandre; Sehrt, David; Kim, Fernando J; Monga, Manoj

    2014-04-01

    To evaluate the association of preoperative noncontrast computed tomography stone characteristics, laser settings, and stone composition with cumulative holmium:yttrium-aluminum-garnet (Ho:YAG) laser time/energy. We retrospectively reviewed patients who underwent semirigid/flexible ureteroscopy and Ho:YAG laser lithotripsy (200 or 365 μm laser fiber; 0.8-1.0 J energy; and 8-10 Hz rate) at 2 tertiary care centers (April 2010-May 2012). Studied parameters were as follows: patient's characteristics; stone characteristics (location, burden, hardness, and composition); total laser time and energy; and surgical outcomes. One hundred patients met our inclusion criteria. Mean stone size was 1.01 ± 0.42 cm and volume 0.33 ± 0.04 cm(3). Mean stone radiodensity was 990 ± 296 HU, and Hounsfield units density 13.8 ± 6.0 HU/mm. All patients were considered stone free. Stone size and volume had a significant positive correlation with laser energy (R = 0.516, P <.001; R = 0.621, P <.001) and laser time (R = 0.477, P <.001; R = 0.567, P <.001). When controlling for stone size, only the correlation between HU and laser time was significant (R = 0.262, P = .011). In the multivariate analysis, with exception of stone composition (P = .103), all parameters significantly increased laser energy (R(2) = 0.524). Multivariate analysis revealed a positive significant association of laser time with stone volume (P <.001) and Hounsfield units density (P <.001; R(2) = 0.512). In multivariate analysis for laser energy, only calcium phosphate stones required less energy to fragment compared with uric acid stones. No significant differences were found in the multivariate laser time model. Ho:YAG laser cumulative energy and total time are significantly affected by stone dimensions, hardness location, fiber size, and power. Kidney location, laser fiber size, and laser power have more influence on the final laser energy than on the total laser time. Calcium phosphate stones require less laser energy to fragment. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. A Miniaturized, 1.9F Integrated Optical Fiber and Stone Basket for Use in Thulium Fiber Laser Lithotripsy.

    PubMed

    Wilson, Christopher R; Hutchens, Thomas C; Hardy, Luke A; Irby, Pierce B; Fried, Nathaniel M

    2015-10-01

    The thulium fiber laser (TFL) is being explored as an alternative laser lithotripter to the standard holmium:yttrium-aluminum-garnet laser. The more uniform beam profile of the TFL enables higher power transmission through smaller fibers. In this study, a 100-μm core, 140-μm outer-diameter (OD) silica fiber with 5-mm length hollow steel tip was integrated with 1.3F (0.433-mm OD) nitinol wire basket to form a 1.9F (0.633-mm OD) device. TFL energy of 30 mJ, 500 μs pulse duration, and 500 Hz pulse rate was delivered to human uric acid stones, ex vivo. Stone ablation rates measured 1.5 ± 0.2 mg/s, comparable to 1.7 ± 0.3 mg/s using bare fiber tips separately with stone basket. With further development, this device may minimize stone retropulsion, allowing more efficient TFL lithotripsy at higher pulse rates. It may also provide increased flexibility, higher saline irrigation rates through the ureteroscope working channel, reduce fiber degradation compared with separate fiber and basket manipulation, and reduce laser-induced nitinol wire damage.

  7. The holmium laser in urology.

    PubMed

    Wollin, T A; Denstedt, J D

    1998-02-01

    To review the physics related to the holmium laser, its laser-tissue interactions, and its application to the treatment of urological diseases. The holmium: YAG laser is a solid-state, pulsed laser that emits light at 2100 nm. It combines the qualities of the carbon dioxide and neodymium:YAG lasers providing both tissue cutting and coagulation in a single device. Since the holmium wavelength can be transmitted down optical fibers, it is especially suited for endoscopic surgery. The authors provide a review of the literature as it relates to the holmium laser and its application to urology. The holmium wavelength is strongly absorbed by water. Tissue ablation occurs superficially, providing for precise incision with a thermal injury zone ranging from 0.5 to 1.0 mm. This level of coagulation is sufficient for adequate hemostasis. The most common urologic applications of the holmium laser that have been reported include incision of urethral and ureteral strictures; ablation of superficial transitional cell carcinoma; bladder neck incision and prostate resection; and lithotripsy of urinary calculi. The holmium: YAG laser is a multi-purpose, multi-specialty surgical laser. It has been shown to be safe and effective for multiple soft tissue applications and stone fragmentation. Its utilization in urology is anticipated to increase with time as a result of these features.

  8. [Effects of retroperitoneal laparoscopic ureterolithotomy and flexible-ureteroscopic holmium laser lithotripsy for complex upper ureteral calculi].

    PubMed

    Zhang, L J; Wu, B; Zha, Z L; Zhao, H; Yang, W; Chen, X H; Jiang, B; Huang, Q; Li, W J; Yuan, J

    2017-10-01

    Objective: To explore the clinical effects of retroperitoneal laparoscopic ureterolithotomy (RPLU) and flexible-ureteroscopic holmium laser lithotripsy (f-UHLL) for complicated upper ureteral calculi. Methods: A total of 45 cases of complicated upper ureteral calculi between March 2014 and January 2016 in Department of Urology, Affiliated Jiangyin Hospital of Southeast University Medical College were retrospectively analyzed, there were 32 males and 13 females, ranging from 27 to 45 years with an average age of (34.1±9.5) years. Of the 45 patients, 28 had ureteral distortion and 17 had concurrent ureteral stones in the lower or middle ipsilateral ureter. In those patients, 20 cases underwent f-UHLL, and 25 cases received RPLU. The stone size, operation time, hospital stay, stone clearance rates and postoperative fever rates between the two groups were compared with t test and χ(2)test. Results: The operation was successfully performed in all patients, no complications with leakage of urine or ureteral perforation occurred, and no significant difference in renal function between the two methods were founded in postoperative period. There was no significant difference in operation time((78.4±8.5) minuetes vs .(73.3±11.3) minuetes, t =0.61, P =0.67), time of double J tube removed ((33.8±3.4)days vs . (37.6±8.9) d, t =2.37, P =0.08) and ipsilateral renal glomerular filtration rates ((41.3±7.6)ml/minuetes vs .(40.5±7.1) ml/min, t =0.78, P =1.27) between the two groups. However, the hospitalization time ((5.9±1.7)days vs . (4.2±1.6) days, t =1.92, P =0.04), postoperative fever rates (4% vs .30%, χ(2)=5.72, P =0.03) and calculus clearance rates (100% vs . 75%, χ(2)=7.03, P =0.01) in RPLU were significantly higher than f-UHLL. Besides, 5 patients in the f-UHLL group had postoperative stone residue and were treated with extracorpore shock wave lithotripsy. Conclusions: Both RPLU and f-UHLL are safety and validity for complex upper ureteral calculi. RPLU can improve the rate of calculus removal and reduce the rate of postoperative fever.

  9. Holmium:YAG laser coronary angioplasty: quantitative angiography and clinical results in a large experience of a single medical center

    NASA Astrophysics Data System (ADS)

    Topaz, On; Luxenberg, Michael; Schumacher, Audrey

    1994-07-01

    Clinical experience with the mid IR holmium:YAG laser in a single medical center (St. Paul Ramsey Medical Center, University of Minnesota Medical School, St. Paul, MN) includes 112 patients who underwent holmium laser coronary angioplasty. Utilizing a unique lasing technique; `pulse and retreat,' we applied this laser to thrombotic and nonthrombotic lesions in patients presenting with unstable angina, stable angina, and acute myocardial infarction. A very high clinical success and very low complication rates were achieved. Holmium:YAG laser is effective and safe therapy for patients with symptomatic coronary artery disease. Unlike excimer lasers, the clinical success, efficacy and safety of holmium laser angioplasty is not compromised when thrombus is present.

  10. Application of the holmium:YAG laser for prostatectomy.

    PubMed

    Kabalin, J N; Gilling, P J; Fraundorfer, M R

    1998-02-01

    The authors review the current knowledge regarding the application of the Holmium: YAG laser for prostatectomy. Conventional surgical therapies for benign prostatic hyperplasia (BPH) are effective but associated with relatively high morbidity. Laser prostatectomy, using either Neodymium:YAG or potassium-titanyl-phosphate lasers, has emerged as a new and much safer operative approach to relieve symptoms of benign prostatic hyperplasia. However, these laser wavelengths possess key disadvantages that have limited their acceptability and dissemination in everyday urologic practice. THE authors review their own extensive experience in the development of clinical application of Holmium: YAG laser technology for prostatectomy, as well as the published reports in the current medical literature now dealing with this subject. In multiple clinical trials, Holmium:YAG laser resection of the prostate has proven efficacious in relieving symptomatic BPH. Both objective urodynamic measures of voiding outcomes and symptomatic improvement have been shown to be equivalent to standard electrocautery resection of the prostate. At the same time, these studies have demonstrated the superior safety and hemostasis of Holmium:YAG laser prostatectomy compared to electrocautery resection, similar to prior laser prostatectomy procedure. Unlike prior forms of laser prostatectomy, Holmium:YAG laser resection of the prostate acutely removes all obstructing prostate tissue, so that the postoperative catheterization requirement is typically only overnight and improvement in voiding is immediate. Current operative techniques and the latest technological developments to facilitate Holmium:YAG laser prostatectomy are described. Holmium: YAG laser prostatectomy combines the best features of prior laser prostatectomy technologies, including minimal complications and morbidity, with the efficacy and immediacy of voiding outcomes associated with conventional electrocautery resection of the prostate.

  11. Holmium:YAG (lambda = 2,120 nm) versus thulium fiber (lambda = 1,908 nm) laser lithotripsy.

    PubMed

    Blackmon, Richard L; Irby, Pierce B; Fried, Nathaniel M

    2010-03-01

    The holmium:YAG laser is currently the most common laser lithotripter. However, recent experimental studies have demonstrated that the thulium fiber laser is also capable of vaporizing urinary stones. The high-temperature water absorption coefficient for the thulium wavelength (mu(a) = 160 cm(-1) at lambda = 1,908 nm) is significantly higher than for the holmium wavelength (mu(a) = 28 cm(-1) at lambda = 2,120 nm). We hypothesize that this should translate into more efficient laser lithotripsy using the thulium fiber laser. This study directly compares stone vaporization rates for holmium and thulium fiber lasers. Holmium laser radiation pulsed at 3 Hz with 70 mJ pulse energy and 220 microseconds pulse duration was delivered through a 100-microm-core silica fiber to human uric acid (UA) and calcium oxalate monohydrate (COM) stones, ex vivo (n = 10 each). Thulium fiber laser radiation pulsed at 10 Hz with 70 mJ pulse energy and 1-millisecond pulse duration was also delivered through a 100-microm fiber for the same sets of 10 stones each. For the same number of pulses and total energy (126 J) delivered to each stone, the mass loss averaged 2.4+/-0.6 mg (UA) and 0.7+/-0.2 mg (COM) for the holmium laser and 12.6+/-2.5 mg (UA) and 6.8+/-1.7 (COM) for the thulium fiber laser. UA and COM stone vaporization rates for the thulium fiber laser averaged 5-10 times higher than for the holmium laser at 70 mJ pulse energies. With further development, the thulium fiber laser may represent an alternative to the conventional holmium laser for more efficient laser lithotripsy.

  12. Evaluation of a new 240-μm single-use holmium:YAG optical fiber for flexible ureteroscopy.

    PubMed

    Khemees, Tariq A; Shore, David M; Antiporda, Michael; Teichman, Joel M H; Knudsen, Bodo E

    2013-04-01

    Numerous holmium:yttrium-aluminum-garnet laser fibers are available for flexible ureteroscopy. Performance and durability of fibers can vary widely among different manufacturers and their product lines with differences within a single product line have been reported. We sought to evaluate a newly developed nontapered, single-use 240-μm fiber, Flexiva™ 200 (Boston Scientific, Natick, MA), during clinical use and in a bench-testing model. A total of 100 new fibers were tested after their use in 100 consecutive flexible ureteroscopic lithotripsy procedures by a single surgeon (B.K.). Prospectively recorded clinical parameters were laser pulse energy and frequency settings, total energy delivered and fibers failure. Subsequently, each fiber was bench-tested using an established protocol. Parameters evaluated for were fibers true diameter, flexibility, tip degradation, energy transmission in straight and 180° bend configuration and fibers failure threshold with stress testing. The mean total energy delivered was 2.20 kJ (range 0-18.24 kJ) and most common laser settings used were 0.8 J at 8 Hz, 0.2 J at 50 Hz, and 1.0 J at 10 Hz, respectively. No fiber fractured during clinical procedures. The true fiber diameter was 450 μm. Fiber tips burnt back an average of 1.664 mm, but were highly variable. With laser setting of 400 mJ at 5 Hz, the mean energy transmitted was 451 and 441 mJ in straight and 180° bend configuration, respectively. Thirteen percent of fibers fractured at the bend radius of 0.5 cm with a positive correlation to the total energy transmitted during clinical use identified. Fiber performance was consistent in terms of energy transmission and resistance to fracture when activated in bent configuration. Fiber failure during stress testing showed significant correlation with the total energy delivered during the clinical procedure. The lack of fiber fracture during clinical use may reduce the risk of flexible endoscope damage due to fiber failure.

  13. [Place of the ureteroscopy in the treatment of the children urolithiasis].

    PubMed

    Fotso Kamdem, A; Tekaili, Y; Boillot, B; Dodat, H; Aubert, D

    2010-03-01

    To determine the efficiency and the role of ureteroscopy in the treatment of urolithiasis in children. A multicenter retrospective study was conducted between January 2006 and March 2008 in the department of pediatric surgery and urology of Besançon, Lyon and Grenoble. The clinical data of 17 children having benefited from one or more ureteroscopy procedures for urolithiasis were analyzed. These data concerned age, sex, antecedents of metabolic diseases, existence of a malformed uropathy, how the urolithiasis was discovered, therapeutic indications, endoscopic procedures, type of endoscopic treatment for urolithiasis, results and complications. Twenty-six ureteroscopies were carried out for 17 children (eight girls and nine boys) aged between 9 months and 12 years (mean: 5 (1/2) years old) as a first-line treatment or after extracorporeal shock wave lithotripsy. A 6/7,5 Fr semi-rigid ureteroscope was used in all case. Only once, the operator chose a flexible ureteroscope. Lithotripsy was carried out 15 times with YAG Holmium laser, four times with Swiss Lithoclast and six times by simple extraction with a Dormia type basket .A stent probe was left in place after endoscopy for 14 children. The "stone free" rate was 88% with an average hindsight of 11 months. Two incidents without major complication were recorded: a section of the guide by the laser beam and a perforation with extravasation of the contrast agent. Ureteroscopy is the first-line treatment in isolated ureteral urolithiasis. On the other hand, LEC remains the treatment of choice for Starghon calculi, since LIC should be offered only in the event of failure of LEC. Copyright 2009. Published by Elsevier Masson SAS.

  14. Early complications with the holmium laser

    NASA Astrophysics Data System (ADS)

    Beaghler, Marc A.; Stewart, Steven C.; Ruckle, Herbert C.; Poon, Michael W.

    1997-05-01

    The purpose of this study is to report early complications in our initial experience with the holmium laser in 133 patients. A retrospective study of patients undergoing endourological procedures with the holmium laser was performed. Complications included urinary tract infection (3), post-operative bradycardia (1), inverted T-waves (1), intractable flank pain (1), urinary retention (1), inability to access a lower pole calyx with a 365 micron fiber (9), stone migration (5), termination of procedure due to poor visualization (2). No ureteral perforations or strictures occurred. The holmium laser was capable of fragmenting all urinary calculi in this study. In our initial experience, the holmium laser is safe and effective in the treatment of genitourinary pathology. Use of laser fibers larger than 200 microns occasionally limit deflection into a lower pole or dependent calyx.

  15. A cladding-pumped, tunable holmium doped fiber laser.

    PubMed

    Simakov, Nikita; Hemming, Alexander; Clarkson, W Andrew; Haub, John; Carter, Adrian

    2013-11-18

    We present a tunable, high power cladding-pumped holmium doped fiber laser. The laser generated >15 W CW average power across a wavelength range of 2.043 - 2.171 μm, with a maximum output power of 29.7 W at 2.120 μm. The laser also produced 18.2 W when operating at 2.171 µm. To the best of our knowledge this is the highest power operation of a holmium doped laser at a wavelength >2.15 µm. We discuss the significance of background losses and fiber design for achieving efficient operation in holmium doped fibers.

  16. In vitro comparison of stone retropulsion and fragmentation of the frequency doubled, double pulse nd:yag laser and the holmium:yag laser.

    PubMed

    Marguet, Charles G; Sung, Jeff C; Springhart, W Patrick; L'Esperance, James O; Zhou, Songlin; Zhong, Pei; Albala, David M; Preminger, Glenn M

    2005-05-01

    The frequency doubled, double pulse Nd:YAG (FREDDY) laser (World of Medicine, Berlin, Germany) functions through the generation of a plasma bubble. Upon bubble collapse a mechanical shock wave is generated, causing stone fragmentation. This mechanism of action is in contrast to the holmium laser, which cause stone destruction by vaporization. Observed clinical stone retropulsion and fragmentation with the FREDDY and holmium lasers has prompted a series of in vitro experiments designed to compare laser induced retropulsion and fragmentation with those of a holmium laser and pneumatic lithotrite. For retropulsion a hands-off underwater laboratory setup, including a horizontally oriented silicone tube 1.3 cm in diameter and a holder to keep the stone phantom in contact with the quartz laser fiber or pneumatic probe, was used. Previously weighed, cylindrical Bego stone phantoms (Bego USA, Smithfield, Rhode Island) were placed in the apparatus. Stone fragmentation was performed with the FREDDY or holmium laser, or the pneumatic lithotripter. The FREDDY and holmium lasers were tested at similar pulse energy and frequency settings. As a standard for comparison, a pneumatic lithotrite was tested with a semirigid probe and single pulse settings of 100, 200 and 300 kPa. Stone phantoms underwent 30 shocks per setting. Mean net retropulsion, defined as the final resting point of the stone, as determined by direct measurement, was recorded for each setting. For fragmentation plaster of Paris stone phantoms of known weights were used to compare the fragmentation ability of each laser. Stones phantoms were placed in a hands-off underwater setup, consisting of an inverted silicon syringe and holder immersed in tap water. The laser fiber (365 microm for the holmium and 280 microm for the FREDDY) was placed through the tip of the syringe in contact with the stone phantom. A total of 24 stones were divided into 4 groups of 6 per group. Two groups were fragmented with the FREDDY laser at 300 and 400 J total energy. The other 2 groups were fragmented using the holmium laser at 300 and 480 J total energy. Fragmentation efficiency was determined as percent weight loss. For retropulsion at 160 mJ the FREDDY laser caused stone retropulsion to a mean distance of 7.6, 8.1 and 6.8 cm at settings of 5, 10 and 15 Hz, respectively. At 0.8 J the holmium laser retropulsed the stone to a mean distance of 3.3 and 4.9 cm at settings of 5 and 10 Hz, respectively. The pneumatic device caused stone retropulsion a mean distance of 8.5, 9.9 and 13.8 cm at pressure settings of 100, 200 and 300 kPa, respectively. The FREDDY laser generally caused less retropulsion than the pneumatic device, although this difference was only significant at the highest pneumatic lithoclast setting (p <0.05). At clinically relevant settings the FREDDY laser caused significantly more retropulsion than the holmium laser (p <0.05). For fragmentation at total energy settings of 300 and 400 J the FREDDY laser resulted in 44.9% and 86.8% weight loss, respectively (p <0.05). At settings of 300 and 480 J the holmium:YAG laser resulted in 3.3% and 7.1% weight loss, respectively (p <0.05). At lower frequency settings stone retropulsion was significantly greater with the FREDDY laser compared with the holmium laser. However, retropulsion was significantly less than that caused by the pneumatic lithotripter at all settings. Therefore, we recommend the use of an occlusive device, such as the Stone Cone (Boston Scientific, Natick, Massachusetts) proximal to the calculus during intracorporeal ureteral lithotripsy and in the ureteropelvic junction during percutaneous laser nephrostolithotomy. In vitro stone fragmentation was significantly greater with the FREDDY laser than with the holmium:YAG laser, suggesting that the FREDDY may offer a low cost alternative to the holmium:YAG laser lithotrite in select patients.

  17. Evaluation of six holmium:YAG optical fibers for ureteroscopy: What's new in 2009?

    NASA Astrophysics Data System (ADS)

    Knudsen, Bodo E.; Teichman, Joel M. H.

    2010-02-01

    The holmium:yttrium aluminum garnet (YAG) laser is the gold standard laser for intracorporeal lithotripsy.1 Optical fibers are utilized to transmit laser energy to the surface of a stone for fragmentation via a predominant photothermal mechanism.2 Previous work has demonstrated that performance characteristics of holmium:YAG optical fibers used for laser lithotripsy varies. Performance may difference not only between fibers made by different manufacturers but also between individual fibers produced by the same manufacturer.3,4 Fiber failure with bending, such as during lower pole ureterorenoscopy, can lead to catastrophic endoscope damage resulting in costly repair. Manufacturers continue to develop new holmium:YAG optical fibers. In this study we evaluate a series of newly commercially available fibers using a previously designed testing protocol. This study was designed to determine the performance and threshold for failure of six newly available holmium:YAG laser fibers from Cook Medical and Fibertech Gmbh. We hypothesize that fiber performance will continue to vary amongst different holmium:YAG optical fibers.

  18. Holmium laser enucleation for prostate adenoma greater than 100 gm.: comparison to open prostatectomy.

    PubMed

    Moody, J A; Lingeman, J E

    2001-02-01

    Options for treatment of large (greater than 100 gm.) prostatic adenomas have until now been limited to open surgery or transurethral resection by skilled resectionists. Considerable blood loss, morbidity, extended hospital stay and prolonged recovery occur with open surgery for large prostatic adenomas. Endoscopic surgery for benign prostatic hyperplasia has evolved during the last decade to offer the patient and surgeon significant advantages of transurethral removal of prostatic adenomas. Holmium laser enucleation of the prostate with transurethral tissue morcellation provides significant reductions in morbidity, bleeding and hospital stay for patients with large prostate adenomas. A retrospective review of data on 10 cases of holmium laser enucleation and 10 open prostatectomies for greater than 100 gm. prostatic adenomas was performed from 1998 to 1999 at our institution. Patient demographics, indication for surgery, preoperative and postoperative American Urological Association (AUA) symptom scores, operating time, serum hemoglobin, resected prostatic weight, pathological diagnosis, length of stay and complications were compared. Patient age, indications for surgery (retention, failed medical therapy, high post-void residual, bladder calculi, bladder diverticula and azotemia) and preoperative AUA symptom scores were similar in both groups. Postoperative AUA symptom scores were significantly decreased (p <0.004) in both groups. Operating times were not significantly different. Serum sodium was unchanged by holmium laser enucleation (not significant), and postoperative hemoglobin was not significantly reduced in the holmium laser enucleation group but decreased significantly in the open prostatectomy group (mean decrease 2.9 +/- 0.7 gm., p = 0.0003). Resected weight was greater in the holmium laser enucleation group (151 versus 106 gm., p = 0.07). Length of stay was significantly shorter in the holmium laser enucleation group (2.1 versus 6.1 days, p <0.001). Complications in the holmium laser enucleation group included stress urinary incontinence in 4 cases, prostatic perforation in 1 and urinary retention in 1. No patient treated with holmium laser enucleation was discharged home with an indwelling catheter. Complications in the open prostatectomy group included bladder neck contractures in 2 cases, stress incontinence in 1 and urge incontinence in 1. All patients treated with open prostatectomy were discharged home with an indwelling catheter. Holmium laser enucleation is an effective, safe procedure for large prostatic adenomas with significantly lower morbidity, catheterization duration and length of stay. Performing holmium laser enucleation for large adenomas requires experience. Stress incontinence was seen frequently with laser but was short-term and self-limited. Holmium laser enucleation is a new procedure, and as experience and expertise increase, it may become an attractive alternative to open prostatectomy for patients with large prostate adenomas.

  19. Choledochoscopic Holmium Laser Lithotripsy for Difficult Bile Duct Stones.

    PubMed

    Lv, Shangdong; Fang, Zheping; Wang, Aidong; Yang, Jian; Zhang, Wenlong

    2017-01-01

    The aim of this study was to evaluate the feasibility and efficacy of choledochoscopic holmium laser lithotripsy as a means of removing resistant extrahepatic and intrahepatic bile duct stones. Clinical data on 28 patients who had undergone choledochoscopic holmium laser lithotripsy were analyzed. Complete stone clearance was obtained in 24 patients; small numbers of residual stones in the left or right hepatic duct were found in 4 patients. No severe complications such as hemobilia and bile duct injuries occurred. Choledochoscopic holmium laser lithotripsy is a simple, safe, and effective treatment method for patients with resistant bile duct stones.

  20. Proximal fiber tip damage during Holmium:YAG and thulium fiber laser ablation of kidney stones

    NASA Astrophysics Data System (ADS)

    Wilson, Christopher R.; Hardy, Luke A.; Irby, Pierce B.; Fried, Nathaniel M.

    2016-02-01

    The Thulium fiber laser (TFL) is being studied as an alternative to Holmium:YAG laser for lithotripsy. TFL beam originates within an 18-μm-core thulium doped silica fiber, and its near single mode, Gaussian beam profile enables transmission of higher laser power through smaller fibers than possible during Holmium laser lithotripsy. This study examines whether TFL beam profile also reduces proximal fiber tip damage compared to Holmium laser multimodal beam. TFL beam at wavelength of 1908 nm was coupled into 105-μm-core silica fibers, with 35-mJ energy, 500-μs pulse duration, and pulse rates of 50-500 Hz. For each pulse rate, 500,000 pulses were delivered. Magnified images of proximal fiber surfaces were taken before and after each trial. For comparison, 20 single-use, 270-μm-core fibers were collected after clinical Holmium laser lithotripsy procedures using standard settings (600 mJ, 350 μs, 6 Hz). Total laser energy, number of laser pulses, and laser irradiation time were recorded, and fibers were rated for damage. For TFL studies, output power was stable, and no proximal fiber damage was observed after delivery of 500,000 pulses at settings up to 35 mJ, 500 Hz, and 17.5 W average power. In contrast, confocal microscopy images of fiber tips after Holmium lithotripsy showed proximal fiber tip degradation in all 20 fibers. The proximal fiber tip of a 105-μm-core fiber transmitted 17.5 W of TFL power without degradation, compared to degradation of 270-μm-core fibers after transmission of 3.6 W of Holmium laser power. The smaller and more uniform TFL beam profile may improve fiber lifetime, and potentially reduce costs for the surgical disposables as well.

  1. Novel fiber optic tip designs and devices for laser surgery

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas Clifton

    Fiber optic delivery of laser energy has been used for years in various types of surgical procedures in the human body. Optical energy provides several benefits over electrical or mechanical surgery, including the ability to selectively target specific tissue types while preserving others. Specialty fiber optic tips have also been introduced to further customize delivery of laser energy to the tissue. Recent evolution in lasers and miniaturization has opened up opportunities for many novel surgical techniques. Currently, ophthalmic surgeons use relatively invasive mechanical tools to dissect retinal deposits which occur in proliferative diabetic retinopathy. By using the tight focusing properties of microspheres combined with the short optical penetration depth of the Erbium:YAG laser and mid-IR fiber delivery, a precise laser scalpel can be constructed as an alternative, less invasive and more precise approach to this surgery. Chains of microspheres may allow for a self limiting ablation depth of approximately 10 microm based on the defocusing of paraxial rays. The microsphere laser scalpel may also be integrated with other surgical instruments to reduce the total number of handpieces for the surgeon. In current clinical laser lithotripsy procedures, poor input coupling of the Holmium:YAG laser energy frequently damages and requires discarding of the optical fiber. However, recent stone ablation studies with the Thulium fiber laser have provided comparable results to the Ho:YAG laser. The improved spatial beam profile of the Thulium fiber laser can also be efficiently coupled into a fiber approximately one third the diameter and reduces the risk of damaging the fiber input. For this reason, the trunk optical fiber minus the distal fiber tip can be preserved between procedures. The distal fiber tip, which degrades during stone ablation, could be made detachable and disposable. A novel, low-profile, twist-locking, detachable distal fiber tip interface was designed, assembled, and tested for use in Thulium fiber laser lithotripsy. A 1.00-mm-outer-diameter detachable fiber tip interface was designed, constructed, and tested ex vivo on urinary stones in the laboratory. Similar stone ablation rates between the previously studied tapered distal fiber tip and the detachable fiber tip were measured. For urologists desiring faster TFL lithotripsy procedures, the incorporation of detachable distal fiber tips allows for rapid replacement of damaged fiber tips without concern about the laser to trunk fiber connection. This method for preserving the trunk fiber could be a motivation for integrating a dedicated laser fiber into the ureteroscope, with detachable distal tips, thus freeing the working channel for the use of other surgical instruments. During laser lithotripsy, distal fiber tip degradation increases as the fiber core diameter decreases. However, smaller fiber diameters (≤ 200 microm) are more desirable because of increased saline irrigation rates in the single working channel of the ureteroscope and less impact on ureteroscope deflection. A hollow fiber cap is proposed to reduced fiber tip degradation in small diameter fibers, without compromising stone ablation rates. The disadvantage of the hollow fiber tip observed in the study is the increase in stone retropulsion. However, integrating the hollow fiber tip with a clinically used stone basket may allow for a robust stone ablation instrument that also minimizes retropulsion. These surgical approaches involving novel specialty fiber optic tip designs are discussed in this thesis.

  2. Update on lasers in urology 2014: current assessment on holmium:yttrium-aluminum-garnet (Ho:YAG) laser lithotripter settings and laser fibers.

    PubMed

    Kronenberg, Peter; Traxer, Olivier

    2015-04-01

    The purpose of the study was to review the existing literature on holmium:yttrium-aluminum-garnet laser lithotripsy regarding lithotripter settings and laser fibers. An online search of current and past peer-reviewed literature on holmium laser lithotripsy was performed on several databases, including PubMed, SciElo, and Google Scholar. Relevant studies and original articles about lithotripter settings and laser fibers were examined, and the most important information is summarized and presented here. We examine how the choice of lithotripter settings and laser fibers influences the performance of holmium laser lithotripsy. Traditional laser lithotripter settings are analyzed, including pulse energy, pulse frequency, and power levels, as well as newly developed long-pulse modes. The impact of these settings on ablation volume, fragment size, and retropulsion is also examined. Advantages of small- and large-diameter laser fibers are discussed, and controversies are highlighted. Additionally, the influence of the laser fiber is examined, specifically the fiber tip preparation and the lithotripter settings' influence on tip degradation. Many technical factors influence the performance of holmium laser lithotripsy. Knowing and understanding these controllable parameters allows the urologist to perform a laser lithotripsy procedure safely, efficiently, and with few complications.

  3. Complications employing the holmium:YAG laser.

    PubMed

    Beaghler, M; Poon, M; Ruckle, H; Stewart, S; Weil, D

    1998-12-01

    We report the operative and early postoperative complications and limitations in 133 patients treated with the holmium laser. Complications included urinary tract infection (N = 3), postoperative bradycardia (1), inverted T-waves (1), intractable flank pain (1), urinary retention (1), inability to access a lower-pole calix with a 365-microm fiber (9), stone migration (5), and termination of procedure because of poor visibility (2). No ureteral perforations or strictures occurred, and no complications were directly attributable to the laser. The holmium laser was capable of fragmenting all urinary calculi in this study. In our initial experience, the holmium laser is safe and effective in the treatment of urinary pathology. Use of laser fibers larger than 200 microm occasionally limits deflection of the endoscope into a lower-pole or dependent calix.

  4. Holmium:YAG (lambda=2120nm) vs. Thulium fiber (lambda=1908nm) laser for high-power vaporization of canine prostate tissue

    NASA Astrophysics Data System (ADS)

    Casperson, Andrew L.; Barton, Robert A.; Scott, Nicholas J.; Fried, Nathaniel M.

    2008-02-01

    Direct studies comparing different lasers for treatment of BPH are lacking. This preliminary study compares continuous-wave (CW) vs. pulsed prostate tissue vaporization for the Thulium fiber laser and Holmium:YAG laser, both operating near the 1940 nm water absorption peak in tissue. A 50-W Thulium fiber laser (λ= 1908 nm) delivered CW laser radiation through a 600-μm silica fiber in non-contact mode with a 5-mm-diameter spot at the tissue surface. A Holmium:YAG laser (λ= 2120 nm) operated with an energy of 2 J, pulse rate of 25 Hz, and average power of 50 W, and delivered pulsed laser radiation through a 600-μm silica fiber with a 5-mm-diameter laser spot to achieve similar irradiances at the tissue surface. Tissue vaporization was performed in air with the prostate kept hydrated in saline. Tissue vaporization efficiency of both lasers was compared (n = 10 canine prostates for each laser group). Mean vaporization efficiency measured 5.30 +/- 0.48 kJ/g vs. 4.13 +/- 0.46 kJ/g for Thulium fiber and Holmium lasers (P < 0.05). Tissue vaporization rates measured 0.57 +/- 0.05 g/min vs. 0.73 +/- 0.07 g/min (P < 0.05). The Holmium:YAG laser vaporizes prostate tissue at a higher rate than the Thulium fiber laser, for the same average power delivered to the tissue. Both the Thulium fiber laser and Holmium:YAG lasers are capable of vaporizing prostate tissue at a rate > 1 g/min if operated at the high powers (100-W) typically used in the clinic.

  5. Comparison of pneumatic and laser lithotripsy in the treatment of pediatric ureteral stones.

    PubMed

    Atar, Murat; Bodakci, Mehmet Nuri; Sancaktutar, Ahmet Ali; Penbegul, Necmettin; Soylemez, Haluk; Bozkurt, Yasar; Hatipoglu, Namik Kemal; Cakmakci, Suleyman

    2013-06-01

    To compare the effectiveness and safety of pneumatic and holmium:YAG laser lithotripters in the treatment of pediatric ureterolithiasis. Medical records of patients treated using pneumatic (PL) (n = 29) or laser (LL) (n = 35) lithotripter between 2009 and 2011 were retrospectively analysed. The patients were evaluated with respect to age, gender, stone size, complications, and stone-free rates 1 month after the operation. For the PL and LL groups, mean ages (8.8 ± 3.4 and 8.3 ± 3.5 years), male/female ratios (19:10 and 22:13) and stone locations were similar (p > 0.05). Mean stone sizes were 55.6 mm2 and 47.6 mm2 in the PL and LL group, respectively, with no statistically significant difference (p = 0.850). Mean operative times were 20.5 min in the PL group and 25.2 min in the LL group, with a statistically significant difference (p = 0.020). Stone-free rates 1 month after intervention were 79% in the PL group and 97% in the LL group (p = 0.022). Stone migration was detected in the PL group (n = 6) and in the LL group (n = 1). No major complication was found in either group. In the ureteroscopic treatment of pediatric ureterolithiasis, both pneumatic and laser lithotripters are effective and successful. However, laser lithotripsy has a higher stone-free rate and lower complication rate. Copyright © 2012 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  6. Efficacy and safety of Ho:YAG laser lithotripsy for ureteroscopic removal of proximal and distal ureteral calculi.

    PubMed

    Khoder, Wael Y; Bader, Markus; Sroka, Ronald; Stief, Christian; Waidelich, Raphaela

    2014-08-08

    Laser lithotripsy is an established endourological modality. Ho:YAG laser have broadened the indications for ureteroscopic stone managements to include larger stone sizes throughout the whole upper urinary tract. Aim of current work is to assess efficacy and safety of Ho:YAG laser lithotripsy during retrograde ureteroscopic management of ureteral calculi in different locations. 88 patients were treated with ureteroscopic Ho:YAG laser lithotripsy in our institute. Study endpoint was the number of treatments until the patient was stone-free. Patients were classified according to the location of their stones as Group I (distal ureteric stones, 51 patients) and group II (proximal ureteral stones, 37). Group I patients have larger stones as Group II (10.70 mm vs. 8.24 mm, respectively, P = 0.020). Overall stone free rate for both groups was 95.8%. The mean number of procedures for proximal calculi was 1.1 ± 0.1 (1-3) and for distal calculi was 1.0 ± 0.0. The initial treatment was more successful in patients with distal ureteral calculi (100% vs. 82.40%, respectively, P = 0.008). No significant difference in the stone free rate was noticed after the second laser procedure for stones smaller versus larger than 10 mm (100% versus 94.1%, P = 0.13). Overall complication rate was 7.9% (Clavien II und IIIb). Overall and grade-adjusted complication rates were not dependent on the stone location. No laser induced complications were noticed. The use of the Ho:YAG laser appears to be an adequate tool to disintegrate ureteral calculi independent of primary location. Combination of the semirigid and flexible ureteroscopes as well as the appropriate endourologic tools could likely improve the stone clearance rates for proximal calculi regardless of stone-size.

  7. Use of the holmium:YAG laser in urology

    NASA Astrophysics Data System (ADS)

    Mattioli, Stefano

    1997-12-01

    The Holmium-YAG is a versatile laser with multiple soft- tissue applications including tissue incision and vaporization, and pulsed-laser applications such as lithotripsy. At 2140 nanometers, the wavelength is highly absorbed by tissue water. Further, like CO2 laser, the Holmium produces immediate tissue vaporization while minimizing deep thermal damage to surrounding tissues. It is an excellent instrument for endopyelotomy, internal urethrotomy, bladder neck incisions and it can be used to resect the prostate. The Holmium creates an acute TUR defect which gives immediate results like the TURP. More than 50 patients were treated from Jan. 1996 to Jan. 1997 for obstructive symptoms due to benign prostatic hyperplasia, bladder neck stricture, urethral stenosis, and superficial bladder tumors.

  8. Wound repair in rat urinary bladder following electrocautery or holmium laser incision

    NASA Astrophysics Data System (ADS)

    Venzi, Giordano; Schmidlin, Franz R.; Gabbiani, Giulio; Delacretaz, Guy P.; Pittet, Brigitte; Leisinger, Hans-Juerg; Iselin, Christoph E.

    1999-06-01

    Woundhealing is a complex phenomenon which varies according the type of tissue but is also depending from the type of tissue injury. Electrocautery mainly induces coagulation necrosis while thermal damages induced by the Holmium laser primarily lead to tissue vaporization which may induce less tissue injury. The aim of this study was to evaluate the healing process of the Holmium laser induced lesions compared to electrocautery induced lesions in urothelial tissue by assessing the inflammatory response and myofibroblast behavior in sequential healing phases. A surgical wound was created in the urinary rat bladder of 32 rats either by electrocautery or by laser (N=16). The inflammatory response, the total lesion depth and the myofibroblast activity during woundhealing was then analyzed on a qualitative basis on days 0/2/4/8. The overall inflammatory response was comparable in both groups up to days two and four. However, at day eight less cellular inflammatory reaction and less myofibroblast activity was found in the specimen of lesions created by the Holmium laser. These results suggest that wound repair may be a less invasive process after Holmium laser than electrocautery.

  9. Long-Term Outcomes of Laser Prostatectomy for Storage Symptoms: Comparison of Serial 5-Year Followup Data between High Performance System Photoselective Vaporization and Holmium Laser Enucleation of the Prostate.

    PubMed

    Cho, Min Chul; Song, Won Hoon; Park, Juhyun; Cho, Sung Yong; Jeong, Hyeon; Oh, Seung-June; Paick, Jae-Seung; Son, Hwancheol

    2018-06-01

    We compared long-term storage symptom outcomes between photoselective laser vaporization of the prostate with a 120 W high performance system and holmium laser enucleation of the prostate. We also determined factors influencing postoperative improvement of storage symptoms in the long term. Included in our study were 266 men, including 165 treated with prostate photoselective laser vaporization using a 120 W high performance system and 101 treated with holmium laser enucleation of the prostate, on whom 60-month followup data were available. Outcomes were assessed serially 6, 12, 24, 36, 48 and 60 months postoperatively using the International Prostate Symptom Score, uroflowmetry and the serum prostate specific antigen level. Postoperative improvement in storage symptoms was defined as a 50% or greater reduction in the subtotal storage symptom score at each followup visit after surgery compared to baseline. Improvements in frequency, urgency, nocturia, subtotal storage symptom scores and the quality of life index were maintained up to 60 months after photoselective laser vaporization or holmium laser enucleation of the prostate. There was no difference in the degree of improvement in storage symptoms or the percent of patients with postoperative improvement in storage symptoms between the 2 groups throughout the long-term followup. However, the holmium laser group showed greater improvement in voiding symptoms and quality of life than the laser vaporization group. On logistic regression analysis a higher baseline subtotal storage symptom score and a higher BOOI (Bladder Outlet Obstruction Index) were the factors influencing the improvement in storage symptoms 5 years after prostate photoselective laser vaporization or holmium laser enucleation. Our serial followup data suggest that storage symptom improvement was maintained throughout the long-term postoperative period for prostate photoselective laser vaporization with a 120 W high performance system and holmium laser enucleation without any difference between the 2 surgeries. Also, more severe storage symptoms at baseline and a more severe BOOI predicted improved storage symptoms in the long term after each surgery. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Efficacy of percutaneous treatment of biliary tract calculi using the holmium:YAG laser.

    PubMed

    Hazey, J W; McCreary, M; Guy, G; Melvin, W S

    2007-07-01

    Few Western studies have focused on percutaneous techniques using percutaneous transhepatic choledochoscopy (PTHC) and holmium:yttrium-aluminum-garnet (YAG) laser to ablate biliary calculi in patients unable or unwilling to undergo endoscopic or surgical removal of the calculi. The authors report the efficacy of the holmium:YAG laser in clearing complex biliary calculi using percutaneous access techniques. This study retrospectively reviewed 13 non-Asian patients with complex secondary biliary calculi treated percutaneously using holmium:YAG laser. Percutaneous access was accomplished via left, right, or bilateral hepatic ducts and upsized for passage of a 7-Fr video choledochoscope. Lithotripsy was performed under choledochoscopic vision using a holmium:YAG laser with 200- or 365-microm fibers generating 0.6 to 1.0 joules at 8 to 15 Hz. Patients underwent treatment until stone clearance was confirmed by PTHC. Downsizing and subsequent removal of percutaneous catheters completed the treatment course. Seven men and six women with an average age of 69 years underwent treatment. All the patients had their biliary tract stones cleared successfully. Of the 13 patients, 3 were treated solely as outpatients. The average length of percutaneous access was 108 days. At this writing, one patient still has a catheter in place. The average number of holmium:YAG laser treatments required for stone clearance was 1.6, with no patients requiring more than 3 treatments. Of the 13 patients, 8 underwent a single holmium:YAG laser treatment to clear their calculi. Prior unsuccessful attempts at endoscopic removal of the calculi had been experienced by 7 of the 13 patients. Five patients underwent percutaneous access and subsequent stone removal as their sole therapy for biliary stones. Five patients were cleared of their calculi after percutaneous laser ablation of large stones and percutaneous basket retrieval of the remaining stone fragments. There was one complication of pain requiring admission, and no deaths. The use of PTHC with holmium:YAG laser ablation is safe and efficacious, but requires prolonged biliary access and often multiple procedures to ensure clearance of all calculi.

  11. The evaluation of tissue mass loss in the incision line of prostate with benign hyperplasia performed using holmium laser and cutting electrode.

    PubMed

    Szewczyk, Mariusz; Jesionek-Kupnicka, Dorota; Lipiński, Marek Ireneusz; Lipinski, Piotr; Różański, Waldemar

    2014-01-01

    The aim of this study is to compare the changes in the incision line of prostatic adenoma using a monopolar cutting electrode and holmium laser, as well as the assessment of associated tissue mass and volume loss of benign prostatic hyperplasia (BPH). The material used in this study consisted of 74 preparations of prostatic adenoma obtained via open retropubic adenomectomy, with an average volume of 120.7 ml. The material obtained cut in vitro before fixation in formaldehyde. One lobe was cut using holmium laser, the other using a monopolar cutting electrode. After the incision was made, tissue mass and volume loss were evaluated. Thermocoagulation changes in the incision line were examinedunder light microscope. In the case of the holmium laser incision, the average tissue mass loss was 1.73 g, tissue volume loss 3.57 ml and the depth of thermocoagulation was 1.17 mm. When the monopolar cutting electrode was used average tissue mass loss was 0.807 g, tissue volume loss 2.48 ml and the depth of thermocoagulation was 0.19 mm. Where holmium laser was used, it was observed that the layer of tissue with thermocoagulation changes was deeper than in the case of the monopolar cutting electrode. Moreover, it was noticed that holmium laser caused bigger tissue mass and volume loss than the cutting electrode.

  12. Holmium:YAG laser: 12-year study of indications for use and outcomes in benign and malignant otolaryngological conditions.

    PubMed

    Joseph, J; Jaberoo, M-C; Dilkes, M

    2010-08-01

    We present the largest recorded case series of holmium:YAG laser use in otolaryngology. This laser's hand-held delivery device is easier to manipulate compared with other ENT lasers, and its pulsed delivery mode gives it enhanced cutting and coagulation properties. We conducted a 12-year, retrospective study of holmium:YAG laser use in a tertiary referral centre. Sixty-eight patients were included. Nineteen received primary laser treatment of squamous cell carcinoma of the upper aerodigestive tract (nine with simultaneous neck dissection), and 49 underwent either palatine or lingual tonsillectomy for benign disease. One cancer patient developed a pharyngo-cutaneous fistula, and a second suffered a secondary haemorrhage. No other complications were recorded. There were no local recurrences. The holmium:YAG laser is safe and effective for benign and malignant otolaryngological conditions. In cancer treatment, it may be best to delay neck dissection until the primary site has healed, in order to avoid fistula formation.

  13. Holmium:YAG and erbium:YAG laser interaction with hard and soft tissue

    NASA Astrophysics Data System (ADS)

    Charlton, Andrew; Dickinson, Mark R.; King, Terence A.; Freemont, Anthony J.

    1991-06-01

    The holmium YAG and erbium YAG lasers operating at 2.1 micrometers and 2.9 micrometers respectively, are the subject of great interest for various medical applications. The interaction of both these pulsed lasers with biological tissue involves absorption of the radiation by water leading to rapid heating and ablation, however the different absorption coefficients at these two wavelengths give rise to different ablation efficiencies and haemostatic properties for the two lasers. It is this cut/seal ratio that determines for which medical applications each of these lasers is most suited. The lasers were used to produce incisions in various tissues by translating the tissue at fixed speed beneath a focused laser beam. The laser energy density was varied between 100 and 500 J/cm2 and the lasers were operated at 2 Hz. After irradiation the tissues were fixed in formalin, processed routinely into paraffin wax, sectioned at 5 micrometers and stained with haemotoxylin and eosin. This allowed the dimensions of the incisions to be measured, as well as the depth of coagulative denatured tissue surrounding each incision. In this way the cut/seal ratio was determined for both the holmium YAG and erbium YAG laser in a range of hard and soft tissues. Results show that the latent heat of ablation for the holmium YAG laser interacting with soft tissue varies between 20-50 kJ/cm3, almost an order of magnitude larger than with the erbium YAG laser. Furthermore, the depth of coagulative necrosis with holmium YAG extends 100-400 micrometers , compared with 10-30 micrometers for erbium YAG. The two interactions clearly lead to vastly different results suggesting that the holmium YAG laser is suitable for producing lesions in highly vascular tissue where haemostasis is important, whereas the erbium YAG laser is better suited to avascular tissue requiring large depths of incision.

  14. Cystoscopic suture removal by Holmium-YAG laser after Burch procedure

    PubMed Central

    Karaşahin, Emre Kazım; Esin, Sertaç; Alanbay, İbrahim; Ercan, Mutlu Cihangir; Mutlu, Erol; Başer, İskender; Basal, Şeref

    2011-01-01

    Burch colposuspension remains one of the successful operations performed for stress incontinence. Accidental suturing of the bladder wall during the procedure or subsequent erosion may lead to lower urinary tract symptoms. Diagnosis and management of these sutures indicate precise evaluation for which a 70 degree cystoscope is used. In selected cases, Holmium-YAG laser may enable us to manage long-standing, encrustated neglected sutures. Here we would like to report successful removal of intravesical sutures using the Holmium-YAG laser. PMID:24591960

  15. Efficacy and safety of Ho:YAG Laser Lithotripsy for ureteroscopic removal of proximal and distal ureteral calculi

    PubMed Central

    2014-01-01

    Background Laser lithotripsy is an established endourological modality. Ho:YAG laser have broadened the indications for ureteroscopic stone managements to include larger stone sizes throughout the whole upper urinary tract. Aim of current work is to assess efficacy and safety of Ho:YAG laser lithotripsy during retrograde ureteroscopic management of ureteral calculi in different locations. Methods 88 patients were treated with ureteroscopic Ho:YAG laser lithotripsy in our institute. Study endpoint was the number of treatments until the patient was stone-free. Patients were classified according to the location of their stones as Group I (distal ureteric stones, 51 patients) and group II (proximal ureteral stones, 37). Group I patients have larger stones as Group II (10.70 mm vs. 8.24 mm, respectively, P = 0.020). Results Overall stone free rate for both groups was 95.8%. The mean number of procedures for proximal calculi was 1.1 ± 0.1 (1–3) and for distal calculi was 1.0 ± 0.0. The initial treatment was more successful in patients with distal ureteral calculi (100% vs. 82.40%, respectively, P = 0.008). No significant difference in the stone free rate was noticed after the second laser procedure for stones smaller versus larger than 10 mm (100% versus 94.1%, P = 0.13). Overall complication rate was 7.9% (Clavien II und IIIb). Overall and grade-adjusted complication rates were not dependant on the stone location. No laser induced complications were noticed. Conclusions The use of the Ho:YAG laser appears to be an adequate tool to disintegrate ureteral calculi independent of primary location. Combination of the semirigid and flexible ureteroscopes as well as the appropriate endourologic tools could likely improve the stone clearance rates for proximal calculi regardless of stone-size. PMID:25107528

  16. Quantification of holmium:YAG optical tip degradation

    NASA Astrophysics Data System (ADS)

    Mues, Adam C.; Teichman, Joel M. H.; Knudsen, Bodo E.

    2009-02-01

    The holmium:yttrium aluminum garnet (YAG) laser is the gold standard laser for intracorporeal lithotripsy. Optical fibers are utilized to transmit laser energy to the surface of a stone for fragmentation. During lithotripsy, fiber tip degradation (burn back) can occur. The exact mechanism for tip degradation and related factors are not completely understood, and have not been investigated. This characteristic is important because fiber burn back may affect diminish fragmentation efficiency, increase operative time, and increase cost due to the need for fiber replacement. We hypothesize that fiber tip degradation (burn back) varies amongst different commercially available holmium:YAG laser fibers.

  17. Color vision deficits and laser eyewear protection for soft tissue laser applications.

    PubMed

    Teichman, J M; Vassar, G J; Yates, J T; Angle, B N; Johnson, A J; Dirks, M S; Thompson, I M

    1999-03-01

    Laser safety considerations require urologists to wear laser eye protection. Laser eye protection devices block transmittance of specific light wavelengths and may distort color perception. We tested whether urologists risk color confusion when wearing laser eye protection devices for laser soft tissue applications. Subjects were tested with the Farnsworth-Munsell 100-Hue Test without (controls) and with laser eye protection devices for carbon dioxide, potassium titanyl phosphate (KTP), neodymium (Nd):YAG and holmium:YAG lasers. Color deficits were characterized by error scores, polar graphs, confusion angles, confusion index, scatter index and color axes. Laser eye protection device spectral transmittance was tested with spectrophotometry. Mean total error scores plus or minus standard deviation were 13+/-5 for controls, and 44+/-31 for carbon dioxide, 273+/-26 for KTP, 22+/-6 for Nd:YAG and 14+/-8 for holmium:YAG devices (p <0.001). The KTP laser eye protection polar graphs, and confusion and scatter indexes revealed moderate blue-yellow and red-green color confusion. Color axes indicated no significant deficits for controls, or carbon dioxide, Nd:YAG or holmium:YAG laser eye protection in any subject compared to blue-yellow color vision deficits in 8 of 8 tested with KTP laser eye protection (p <0.001). Spectrophotometry demonstrated that light was blocked with laser eye protection devices for carbon dioxide less than 380, holmium:YAG greater than 850, Nd:YAG less than 350 and greater than 950, and KTP less than 550 and greater than 750 nm. The laser eye protection device for KTP causes significant blue-yellow and red-green color confusion. Laser eye protection devices for carbon dioxide, holmium:YAG and Nd:YAG cause no significant color confusion compared to controls. The differences are explained by laser eye protection spectrophotometry characteristics and visual physiology.

  18. Holmium laser use in the treatment of selected dry eye syndrome complications

    NASA Astrophysics Data System (ADS)

    Kecik, Dariusz; Kecik, Tadeusz; Kasprzak, Jan; Kecik, Mariusz

    1996-03-01

    The authors present initial results of treatment selected complications of dry eye syndrome with holmium laser. The lacrimal puncta obliteration and coagulation of the corneal ulcer surface were done.

  19. The evaluation of tissue mass loss in the incision line of prostate with benign hyperplasia performed using holmium laser and cutting electrode

    PubMed Central

    Szewczyk, Mariusz; Jesionek–Kupnicka, Dorota; Lipinski, Piotr; Różański, Waldemar

    2014-01-01

    Introduction The aim of this study is to compare the changes in the incision line of prostatic adenoma using a monopolar cutting electrode and holmium laser, as well as the assessment of associated tissue mass and volume loss of benign prostatic hyperplasia (BPH). Material and methods The material used in this study consisted of 74 preparations of prostatic adenoma obtained via open retropubic adenomectomy, with an average volume of 120.7 ml. The material obtained cut in vitro before fixation in formaldehyde. One lobe was cut using holmium laser, the other using a monopolar cutting electrode. After the incision was made, tissue mass and volume loss were evaluated. Thermocoagulation changes in the incision line were examinedunder light microscope. Results In the case of the holmium laser incision, the average tissue mass loss was 1.73 g, tissue volume loss 3.57 ml and the depth of thermocoagulation was 1.17 mm. When the monopolar cutting electrode was used average tissue mass loss was 0.807 g, tissue volume loss 2.48 ml and the depth of thermocoagulation was 0.19 mm. Conclusions Where holmium laser was used, it was observed that the layer of tissue with thermocoagulation changes was deeper than in the case of the monopolar cutting electrode. Moreover, it was noticed that holmium laser caused bigger tissue mass and volume loss than the cutting electrode. PMID:25247088

  20. [Experimental liver and kidney surgery with CO2, CO, holmium, and neodym lasers. Cutting effect, hemostasis, histopathology, and healing (author's transl)].

    PubMed

    Karbe, E; Königsmann, G; Beck, R

    1980-01-01

    Various laser devices (CO2, CO, Nd: YAG, and holmium: YAG lasers) have been used on pig livers and on dog kidneys for comparison with conventional surgical instruments (electroscalpel, cryoscalpel, and scalpel). CO2 and CO lasers caused the least tissue damage, followed by the holmium laser; severe damage was caused by the Nd: YAG laser. The order was reverse for coagulative effect. The conventional reference instruments showed a weaker hemostatic effect. Surfaces cut by laser healed in four to eight weeks without complications. Remnants of charred tissue in various quantities could still be detected after eight weeks in all cases where CO2, CO, and Nd: YAG lasers had been used. This obviously did not affect scar formation.

  1. Lasers in the management of calcified urinary tract stents

    NASA Astrophysics Data System (ADS)

    Nseyo, Unyime O.; Tunuguntla, Hari S. G. R.; Crone, Michael

    2003-06-01

    Indwelling double J ureteral stents are used for internal urinary diversion for ureteral obstruction and post-surgical drainage of the upper urinary tract. Stent calcification is a serious complication especially in those with forgotten stents. In a retrospective review of 16 patients (10 male and 6 female) we found holmium laser to be highly effective in the management of calcified stents. Encrustations/calcifications were noted on the distal end of the sent in 6 patiens (37.5%), middle and distal portions in 2 patients (12.5%), along the entire length of the stent in 3 patients (18.75%), lower portion of the stent in 4 patients (25%) and at the upper and lower ends of the stent in one patient (6.25%). Cystolitholapaxy, retrograde ureteroscopy (URS) with holmium: YAG (yttrium-aluminum-garnet) laser intracorporeal lithotripsy, percutaneous nephrostolithotomy (PNL) and antegrade URS with holmium: YAG laser intracorporeal lithotripsy were effectively performed without intraoperative complications. Lithotripsy became necessary before stent removal in 11 patients (68.75%). Holmium laser lithotripsy was useful in managing 7 patients (43.75%), and shockwave lithotripsy (SWL) in 6 patients (37.5%). In two patients (12.5%) both holmium and SWL were used before the stent can be removed.

  2. [Comparison of validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy].

    PubMed

    Bi, Sheng; Xia, Ming

    2015-08-11

    To compare the validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy. A total of 28 patients were divided into two groups (holmium: YAG laser group without renal artery clamping and traditional surgery group with renal artery clamping). The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were recorded. The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were 80 ml, 77 min, 0 min, 7.4 days, 35 ml/min, 0, 0.9 cm, respectively, in holmium: YAG laser group. And in traditional surgery group were 69 ml, 111 min, 25.5 min, 7.3 days, 34 ml/min, 0, 2.0 cm, respectively. The differences of total operative time, renal artery clamping time and depth of tissue injury between two groups were statistically significant. The others were not statistically significant. Holmium: YAG laser is effective and safe in partial nephrectomy. It can decrease the total operative time, minimize the warm ischemia time and enlarge the extent of surgical excision.

  3. Holmium: yttrium aluminum garnet laser-assisted endoscopic sinus surgery: laboratory experience.

    PubMed

    Shapshay, S M; Rebeiz, E E; Bohigian, R K; Hybels, R L; Aretz, H T; Pankratov, M M

    1991-02-01

    Endoscopic sinus surgery has gained wide acceptance since its introduction into the United States. Complex sinus anatomy and troublesome bleeding have been associated with complications, which vary in severity from synechia to blindness and leakage of cerebrospinal fluid. Endoscopic sinus surgery using a holmium: yttrium aluminum garnet pulsed solid-state laser oscillating at 2.1 microns with fiberoptic delivery was performed in the laboratory, and the results were compared with those of conventional endoscopic sinus surgery. Three beagle dogs, six human cadaver heads, and one calf head were used in the in vivo and in vitro studies to evaluate the bone ablation, tissue coagulation, and hemostatic properties of the holmium: yttrium aluminum garnet laser. Modified endoscopic telescopes for sinus surgery, a newly developed handpiece for fiberoptic delivery, and other surgical instruments were used. The results indicate that the holmium: yttrium aluminum garnet laser and new delivery instrumentation provide good hemostasis and controlled soft-tissue ablation and bone removal. The access to all sinuses in the human cadaver model was very good. The canine in vivo study showed delayed but complete healing on the laser-treated side. Clinical evaluation of the holmium: yttrium aluminum garnet laser is warranted to increase the precision and safety of endoscopic sinus surgery.

  4. An algorithm for calculi segmentation on ureteroscopic images.

    PubMed

    Rosa, Benoît; Mozer, Pierre; Szewczyk, Jérôme

    2011-03-01

    The purpose of the study is to develop an algorithm for the segmentation of renal calculi on ureteroscopic images. In fact, renal calculi are common source of urological obstruction, and laser lithotripsy during ureteroscopy is a possible therapy. A laser-based system to sweep the calculus surface and vaporize it was developed to automate a very tedious manual task. The distal tip of the ureteroscope is directed using image guidance, and this operation is not possible without an efficient segmentation of renal calculi on the ureteroscopic images. We proposed and developed a region growing algorithm to segment renal calculi on ureteroscopic images. Using real video images to compute ground truth and compare our segmentation with a reference segmentation, we computed statistics on different image metrics, such as Precision, Recall, and Yasnoff Measure, for comparison with ground truth. The algorithm and its parameters were established for the most likely clinical scenarii. The segmentation results are encouraging: the developed algorithm was able to correctly detect more than 90% of the surface of the calculi, according to an expert observer. Implementation of an algorithm for the segmentation of calculi on ureteroscopic images is feasible. The next step is the integration of our algorithm in the command scheme of a motorized system to build a complete operating prototype.

  5. Endoscopic-assisted disruption of urinary calculi using a holmium:YAG laser in standing horses.

    PubMed

    Judy, Carter E; Galuppo, Larry D

    2002-01-01

    To describe a technique for endoscope-assisted disruption and removal of urinary calculi using a holmium:YAG laser in sedated, standing horses. Retrospective study. Six horses with urinary calculi. A holmium:YAG laser was used to disrupt naturally occurring urinary calculi in horses (4 geldings, 1 stallion, 1 mare). Ischial urethrotomy was performed in male horses to provide a portal for the endoscope and laser fiber. Calculus fragments were removed by a combination of lavage, transendoscopic basket snare removal, forceps, and digital manipulation. Ischial urethrotomies healed by second intention. Follow-up was obtained by recheck examination and telephone interview of owners. No major operative or postoperative complications occurred. Two calculi (1 stallion and 1 mare) were fragmented by a combination of laser ablation and manual disruption with a lithotrite. Postoperative dysuria occurred in the mare, but resolved after 1 month. Mean (+/- SD) follow-up was 306 +/- 149 days; no other complications were reported. Calcium carbonate urinary calculi (up to 15 cm in diameter) in horses can be effectively fragmented with a holmium:YAG laser. It is not known if this technique would be completely effective for larger calculi or extremely dense calculi. Calculus disruption by an endoscopically assisted holmium:YAG laser offers a minimally invasive method that can be performed in standing horses and that minimizes patient risk. Copyright 2002 by The American College of Veterinary Surgeons

  6. A Prospective Randomized Comparison Between Laparoscopic Ureterolithotomy and Semirigid Ureteroscopy for Upper Ureteral Stones >2 cm: A Single-Center Experience.

    PubMed

    Kumar, Anup; Vasudeva, Pawan; Nanda, Biswajit; Kumar, Niraj; Jha, Sanjeev Kumar; Singh, Harbinder

    2015-11-01

    The optimal management method of upper ureteral stones >2 cm is still a challenge. We performed a prospective randomized comparison between laparoscopic ureterolithotomy (LU) and ureteroscopic lithotripsy for upper ureteral calculus >2 cm to evaluate safety and efficacy of both procedures. Between January 2010 and May 2012, 110 patients with a single radiopaque upper ureteral calculus >2 cm were included in the present study. Randomization was done in two groups-group A: LU was performed and group B: Ureteroscopy (URS) was performed using a 6/7.5F semirigid ureteroscope (Richard Wolf) with holmium laser intracorporeal lithotripsy. Statistical analysis was performed regarding demographic profile, success, retreatment, auxiliary procedure rates, and also complications. Out of the total 110 patients, 54 patients were enrolled in group A and 56 patients were enrolled in group B. Mean stone size was 2.3±0.2 cm in group A versus 2.2±0.1 cm in group B (p=0.52). The overall 3-month stone-free rate was (50/50) 100% for group A versus (38/50) 76% for group B (p=0.02). The retreatment rate was significantly greater in group B than group A (8% vs. 0%, respectively; (p=0.01). Auxiliary procedure rate was higher in group B than in group A (26% vs. 0% respectively; p=0.001). The complication rate was 12% in group A versus 26% in group B (p=0.001). For upper ureteral stones of size greater than 2 cm, LU has a greater stone clearance rate, comparable operating time, lesser need for auxiliary procedure, and complication rate as compared to URS.

  7. In vitro analysis of laser meniscectomy.

    PubMed

    Vangsness, C T; Akl, Y; Nelson, S J; Liaw, L H; Smith, C F; Marshall, G J

    1995-01-01

    Partial meniscectomies were performed on 32 fresh human meniscal autopsy specimens. The following laser systems were tested: carbon dioxide (CO2), neodymium:yttrium aluminum garnet (Nd:YAG), potassium titanyl phosphate (KTP), holmium:YAG (Ho:YAG), and excimer. Meniscectomies with these lasers were compared with scalpel, mechanical, and electrocautery meniscectomies. Lasers were applied to specimens in and out of normal saline. Routine hematoxylin and eosin and sirius red sections were prepared for each specimen, and the depths of thermal changes were analyzed. Scanning electron microscopy was used to visualize the meniscectomy interface. Among these specimens, the scalpel and mechanical meniscectomies showed the least extension of cellular changes (range, 10-15 nm). The excimer laser caused the least tissue changes of the lasers tested. Tissue changes were less extensive with the pulsed CO2 laser than with the holmium:YAG, neodymium:YAG, and KTP lasers. Scanning electron microscopy showed that use of the scalpel meniscectomy resulted in the smoothest meniscectomy edge, followed by use of the excimer, CO2, holmium:YAG, neodymium:YAG, and KTP lasers. The most surface disruption occurred with electrocautery. Meniscectomies under saline required more energy and took longer in each case, with the holmium:YAG, neodymium:YAG, and CO2 laser cutting the best. Saline meniscectomies showed less thermal change. The CO2 and KTP lasers cut best in air.

  8. Differentiation of tissue and kidney stones for laser lithotripsy using different spectroscopic approaches

    NASA Astrophysics Data System (ADS)

    Lange, Birgit; Cordes, Jens; Brinkmann, Ralf

    2015-07-01

    Holmium lasers are nowadays the gold standard for endoscopic laser lithotripsy. However, there is a risk of damaging or perforating the ureter or kidney tissue when the vision is poor. An automatic tissue/stone differentiation would improve the handling and safety of the procedure. To achieve this objective, an easy and robust real-time discrimination method has to be found which can be used to realize a feedback loop to control the laser system. Two possible approaches have been evaluated: White light reflectance and fluorescence spectroscopy. In both cases, we use the treatment fiber for detection and evaluate the possibility to decide whether the fiber is placed in front of tissue or calculus by the signal that is delivered by the surface in front of it. White light reflectance spectroscopy uses the standard light source for endourologic surgeries: Radiation of a Xenon light source is coupled to the ureteroscope via a liquid light guide. The part of the white light that is reflected back into the fiber is spectroscopically analyzed. In a clinical proof of concept study reflection signals were measured in vivo in 8 patients. For differentiation of stone and tissue via autofluorescence, excitation as well as detection was done via the treatment fiber. A suitable excitation wavelength was chosen with in vitro measurements (UV / visible) on several human renal calculi and porcine tissues. For verification of the positive results with green excitation in a clinical proof of concept study, a measurement set-up was realized which allows the recording of fluorescence signals during an endourological intervention.

  9. Holmium laser lithotripsy of bladder calculi

    NASA Astrophysics Data System (ADS)

    Beaghler, Marc A.; Poon, Michael W.

    1998-07-01

    Although the overall incidence of bladder calculi has been decreasing, it is still a significant disease affecting adults and children. Prior treatment options have included open cystolitholapaxy, blind lithotripsy, extracorporeal shock wave lithotripsy, and visual lithotripsy with ultrasonic or electrohydraulic probes. The holmium laser has been found to be extremely effective in the treatment of upper tract calculi. This technology has also been applied to the treatment of bladder calculi. We report our experience with the holmium laser in the treatment of bladder calculi. Twenty- five patients over a year and a half had their bladder calculi treated with the Holmium laser. This study was retrospective in nature. Patient demographics, stone burden, and intraoperative and post-operative complications were noted. The mean stone burden was 31 mm with a range of 10 to 60 mm. Preoperative diagnosis was made with either an ultrasound, plain film of the abdomen or intravenous pyelogram. Cystoscopy was then performed to confirm the presence and determine the size of the stone. The patients were then taken to the operating room and given a regional or general anesthetic. A rigid cystoscope was placed into the bladder and the bladder stone was then vaporized using the holmium laser. Remaining fragments were washed out. Adjunctive procedures were performed on 10 patients. These included transurethral resection of the prostate, transurethral incision of the prostate, optic internal urethrotomy, and incision of ureteroceles. No major complications occurred and all patients were rendered stone free. We conclude that the Holmium laser is an effective and safe modality for the treatment of bladder calculi. It was able to vaporize all bladder calculi and provides a single modality of treating other associated genitourinary pathology.

  10. Bone dissemination of prostate cancer after holmium laser enucleation of the prostate: a case report and a review of the literature.

    PubMed

    Koguchi, Dai; Nishi, Morihiro; Satoh, Takefumi; Shitara, Toshiya; Matsumoto, Kazumasa; Fujita, Tetsuo; Yoshida, Kazunari; Iwamura, Masatsugu

    2014-02-01

    We report a case of dissemination of prostate cancer after holmium laser enucleation of the prostate in an 80-year-old patient. The patient presented at hospital because of nocturia. Transrectal ultrasound-guided biopsy was carried out because of high serum prostate-specific antigen (3.55 ng/mL), but it showed no malignancies. Benign prostate hyperplasia was diagnosed, and he was started on an α1-blocker. Although the urinary symptom improved with silodosin, acute urinary retention occurred 3 years after therapy began. Holmium laser enucleation of the prostate for relief of bladder outlet obstruction enabled discharge of urine. Pathological examination of the resected tissue found adenocarcinoma with a high Gleason score, 4 + 5. Serum alkaline phosphatase increased rapidly after holmium laser enucleation, and bone scintigraphy confirmed multiple bone metastases. Prostate cancer, T1bN0M1b, was diagnosed. © 2013 The Japanese Urological Association.

  11. Mid-infrared coronary laser angioplasty with multifiber catheters

    NASA Astrophysics Data System (ADS)

    White, Christopher J.; Ramee, Stephen R.; Collins, Tyrone J.

    1993-06-01

    Mid-infrared laser wavelengths offer advantages as a source for coronary angioplasty based upon the excellent fiberoptic transmission and the enhanced tissue absorption of these photons. We report the results of a pilot clinical trial of a Holmium:YAG (2.1 micrometers ) coronary laser angioplasty using a prototype (1.6 mm and 2.0 mm) multifiber catheters. Coronary laser angioplasty with or without adjunctive balloon angioplasty or directional atherectomy was performed in 14 patients with 17 coronary stenoses. Laser success was obtained in 13/14 (93%) patients and 16/17 (94%) lesions. Uncomplicated procedural success was achieved in 9/14 (64%) patients and 12/17 (71%) lesions. Our initial laser success rate was very encouraging using this prototype multifiber catheter with a holmium:YAG laser. However, our overall procedural success rate was disappointing, and not superior to that expected with conventional angioplasty alone. The holmium laser remains an attractive energy source for laser angioplasty, but its utility is limited by catheters which create inadequate channels for stand-alone laser angioplasty.

  12. Soft-tissue applications of the holmium:YAG laser in urology

    NASA Astrophysics Data System (ADS)

    Denstedt, John D.; Razvi, Hassan A.; Chun, Samuel S.; Sales, Jack L.

    1995-05-01

    The ideal surgical laser for the treatment of soft tissue pathology should possess both ablative and hemostatic abilities. As well, for use in urologic conditions the laser must also be suitable for endoscopic use. The Holmium:YAG laser possesses these qualities and in preliminary clinical use has demonstrated a variety of potential urologic applications. In this study we review our initial experience with the Holmium:YAG laser over a 18 month period. A total of 51 patients underwent 53 procedures for a variety of soft tissue conditions including: bladder tumor ablation (25), incision of ureteral stricture (15), incision of urethral stricture (6), treatment of ureteropelvic junction obstruction (3), incision of bladder neck contracture (2), and ablation of a ureteral tumor (2). Satisfactory hemostasis was achieved in all cases. Procedures were considered successful (no further intervention being required to treat the condition) in 81% of the cases. Two patients with dense bladder neck contractures required electroincision under the same anesthetic for completion of the procedure. A single complication, that of urinary extravasation following incision of a urethral stricture resolved with conservative management. In summary, the Holmium:YAG laser has demonstrated safety and proficiency in the treatment of a variety of urologic soft tissue conditions.

  13. All-fiber passively Q-switched thulium-doped fiber laser by using a holmium-doped fiber as saturable absorber

    NASA Astrophysics Data System (ADS)

    Durán Sánchez, M.; Álvarez-Tamayo, R. I.; Posada-Ramírez, B.; Alaniz-Baylón, J.; Bravo-Huerta, E.; Santiago-Hernández, H.; Hernández-Arriaga, M. V.; Bello-Jiménez, Miguel; Ibarra-Escamilla, B.; Kuzin, E. A.

    2018-02-01

    We report a linear cavity all-fiber passive Q-switched thulium-doped fiber laser operating at the 2 μm wavelength range. The laser configuration is based on a thulium-doped fiber used as a gain medium and an unpumped segment of holmium-doped fiber which acts as a fiber saturable absorber. The cavity is formed by a fiber optical loop mirror and the flat end facet of the holmium-doped fiber. The fiber segments as saturable absorber is a 1-m long single mode doubleclad holmium-doped fiber. Q-switched pulses are obtained at the wavelength of 2024.5 nm with a pulse width of 1.1 μs. The pulse repetition rate increases as a linear function of the applied pump power. The maximum pulse repetition rate of 100 kHz was obtained with a pump power of 2.4 W.

  14. Cost Analysis of Flexible Ureteroscope Repairs: Evaluation of 655 Procedures in a Community-Based Practice.

    PubMed

    Kramolowsky, Eugene; McDowell, Zachary; Moore, Blake; Booth, Brigette; Wood, Nada

    2016-03-01

    The frequency of flexible ureteroscopy has increased with the introduction of improved instrumentation. Ureteroscopes allow increased endoscopic access to the ureter and kidney. However, maintenance and repair of scopes may increase the total procedure expense. In 3 years (8/2011-7/2014), 655 flexible ureteroscopies were performed at a single-specialty, urology, ambulatory surgery center. Procedures were performed by 26 board-certified urologists using four Olympus URF P5 flexible ureteroscopes. The instruments were handled by a single team and sterilized through the STERIS System E1. Repairs were performed by the manufacturer on an as needed basis. Patient records were reviewed to determine the preoperative diagnosis, operative time, location and size of the stone, and use of laser or ureteral sheath. The occurrence, nature of flexible ureteroscope damage, and cost of repairs were evaluated. Of the ureteroscopies performed, 78% was for the treatment of calculi (50.1% in the kidney). Mean stone size was 8.5 ± 0.2 mm, with larger stones (11 mm) located in the kidney. The flexible ureteroscope was advanced over a guidewire (88% of cases); a laser fiber was introduced in 70%, and a ureteral sheath was used in 13.4%. Mean procedure time was 40 minutes. The most common reasons for ureteroscope repair were cloudy lens (16 repairs) and broken optic fibers (9 repairs). There were 31 repairs during the study period (average 21 cases per repair). Flexible ureteroscopes were out of service for an average of 11 days per repair (range 3-20). The total cost of repairs was $233,150 or ∼$7521 per repair. The average repair cost per flexible ureteroscopy performed was $355. Expenses associated with instrument repair can significantly impact a procedure's net revenue, thus efforts should be made to minimize instrument breakage. The expense of repairing a flexible ureteroscope per procedure can be significant and needs to be considered when pricing this procedure.

  15. Robotic Assisted Simple Prostatectomy versus Holmium Laser Enucleation of the Prostate for Lower Urinary Tract Symptoms in Patients with Large Volume Prostate: A Comparative Analysis from a High Volume Center.

    PubMed

    Umari, Paolo; Fossati, Nicola; Gandaglia, Giorgio; Pokorny, Morgan; De Groote, Ruben; Geurts, Nicolas; Goossens, Marijn; Schatterman, Peter; De Naeyer, Geert; Mottrie, Alexandre

    2017-04-01

    We report a comparative analysis of robotic assisted simple prostatectomy vs holmium laser enucleation of the prostate in patients who had benign prostatic hyperplasia with a large volume prostate (greater than 100 ml). A total of 81 patients underwent robotic assisted simple prostatectomy and 45 underwent holmium laser enucleation of the prostate in a 7-year period. Patients were preoperatively assessed with transrectal ultrasound and uroflowmetry. Functional parameters were assessed postoperatively during followup. Perioperative outcomes included operative time, postoperative hemoglobin, catheterization time and hospitalization. Complications were reported according to the Clavien-Dindo classification. Compared to the holmium laser enucleation group, patients treated with prostatectomy were significantly younger (median age 69 vs 74 years, p = 0.032) and less healthy (Charlson comorbidity index 2 or greater in 62% vs 29%, p = 0.0003), and had a lower rate of suprapubic catheterization (23% vs 42%, p = 0.028) and a higher preoperative I-PSS (International Prostate Symptom Score) (25 vs 21, p = 0.049). Both groups showed an improvement in the maximum flow rate (15 vs 11 ml per second, p = 0.7), and a significant reduction in post-void residual urine (-73 vs -100 ml, p = 0.4) and I-PSS (-20 vs -18, p = 0.8). Median operative time (105 vs 105 minutes, p = 0.9) and postoperative hemoglobin (13.2 vs 13.8 gm/dl, p = 0.08) were similar for robotic assisted prostatectomy and holmium laser enucleation, respectively. Median catheterization time (3 vs 2 days, p = 0.005) and median hospitalization (4 vs 2 days, p = 0.0001) were slightly shorter in the holmium laser group. Complication rates were similar with no Clavien grade greater than 3 in either group. Our results from a single center suggest comparable outcomes for robotic assisted simple prostatectomy and holmium laser enucleation of the prostate in patients with a large volume prostate. These findings require external validation at other high volume centers. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Diode-Pumped Thulium (Tm)/Holmium (Ho) Composite Fiber 2.1-Micrometers Laser

    DTIC Science & Technology

    2015-09-01

    composite fiber laser of holmium-core and thulium-doped cladding . The composite fiber was optically pumped by an 803-nm fiber coupled diode source and was...4 odd and 5 even modes were exclusive to the core and first cladding . As the Tm laser modes are excluded from lasing in the second (undoped...of the Tm-doped clad /Ho-doped core fiber laser . In particular, calculations of the model overlap of the cladding modes with the core have been

  17. An integrated fiber and stone basket device for use in Thulium fiber laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Wilson, Christopher R.; Hutchens, Thomas C.; Hardy, Luke A.; Irby, Pierce B.; Fried, Nathaniel M.

    2014-03-01

    The Thulium fiber laser (TFL) is being explored as an alternative laser lithotripter to the Holmium:YAG laser. The TFL's superior near-single mode beam profile enables higher power transmission through smaller fibers with reduced proximal fiber tip damage. Recent studies have also reported that attaching hollow steel tubing to the distal fiber tip decreases fiber degradation and burn-back without compromising stone ablation rates. However, significant stone retropulsion was observed, which increased with pulse rate. In this study, the hollow steel tip fiber design was integrated with a stone basket to minimize stone retropulsion during ablation. A device was constructed consisting of a 100-μm-core, 140-μm-OD silica fiber outfitted with 5-mm-long stainless steel tubing at the distal tip, and integrated with a 1.3-Fr (0.433-mm-OD) disposable nitinol wire basket, to form an overall 1.9-Fr (0.633-mm- OD) integrated device. This compact design may provide several potential advantages including increased flexibility, higher saline irrigation rates through the ureteroscope working channel, and reduced fiber tip degradation compared to separate fiber and stone basket manipulation. TFL pulse energy of 31.5 mJ with 500 μs pulse duration and pulse rate of 500 Hz was delivered through the integrated fiber/basket device in contact with human uric acid stones, ex vivo. TFL stone ablation rates measured 1.5 +/- 0.2 mg/s, comparable to 1.7 +/- 0.3 mg/s (P > 0.05) using standard bare fiber tips separately with a stone basket. With further development, this device may be useful for minimizing stone retropulsion, thus enabling more efficient TFL lithotripsy at higher pulse rates.

  18. Combined use of flexible ureteroscopic lithotripsy with micro-percutaneous nephrolithotomy in pediatric multiple kidney stones.

    PubMed

    Li, Jun; Wang, Wenying; Du, Yuan; Tian, Ye

    2018-03-28

    We investigated the clinical value of treating pediatric multiple kidney stones with extensive distribution using flexible ureteroscopic lithotripsy (FUL) combined with micro-percutaneous nephrolithotomy (micro-PNL). In total, 21 pediatric patients with multiple renal calculi between May 2016 and June 2017 received FUL combined with micro-PNL. The group included 13 boys and eight girls; the patients' mean age was 3.8 years (range 1-8 years). The maximum stone diameter ranged from 1.0 to 1.5 cm. FUL was first performed in the lithotomy position to fragment stones that were located in the renal pelvis, and upper and mid-renal calyx. Patients were then moved to a prone position, and micro-PNL was performed to treat lower pole stones that could not be reached by the flexible ureteroscope during FUL. Percutaneous renal access to the lower calyx was achieved using a 4.8F "all-seeing needle" with ultrasound guidance, and stone fragmentation was performed with a 200-μm holmium laser at different settings to disintegrate 1- to 2-mm fragments. All 21 pediatric patients with multiple kidney stones underwent combined FUL and micro-PNL. The stone free rate (SFR) was 85.7% (18/21). The mean surgical time was 45 min (range 30-70 min). The mean volume of irrigation fluid used was 480 mL (range 300-1200 mL). The mean surgical time for FUL and micro-PNL was 31 min and 14 min, respectively, and the mean volume of fluid used for FUL and micro-PNL was 360 mL and 120 mL, respectively. According to the modified Clavien classification, grade 1 and 2 postoperative complications occurred in five and one patients, respectively. The mean decrease in the level of hemoglobin was 0.4 g/dL (0-0.7 g/dL), and no patients required a transfusion. The average hospital stay was 3 days (range 2-5 days). Combined FUL and micro-PNL is a safe, effective, and minimally invasive operation to remove multiple renal calculi with extensive distribution in children in selected cases. Copyright © 2018 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  19. From coagulation to enucleation: the use of lasers in surgery for benign prostatic hyperplasia.

    PubMed

    Wilson, Liam C; Gilling, Peter J

    2005-09-01

    The application of lasers for the treatment of benign prostatic hyperplasia has evolved over the past 15 years. Early-generation neodymium:yttrium aluminum garnet lasers were used to coagulate and ablate prostatic tissue, but significant postoperative irritative symptoms and high reoperation rates meant that this approach did not seriously challenge the status quo for long. Ablative techniques have recently become popular again with the marketing of the newer-generation, higher-power potassium titanyl phosphate and holmium lasers. Although short-term data are encouraging, there are no comparative trials of significant duration, so it is not yet possible to draw conclusions with regard to efficacy and durability. The holmium laser can also be used as an incisional and dissecting tool that allows resection or enucleation of whole lobes of the prostate, mimicking the action of the index finger in open prostatectomy. The safety, efficacy, durability and cost-effectiveness of the holmium laser have been shown in well-designed randomized controlled trials.

  20. Endoscopic placement of Jones lacrimal tubes with the assistance of holmium YAG laser.

    PubMed

    Boboridis, Kostas G; Downes, Richard N

    2005-06-01

    The aim of this paper is to highlight the use of the Holmium YAG laser in the endoscopic placement of Lester Jones tubes in patients with a blocked canaliculus or failed lacrimal pump function. Sixteen cases with a non-functional canaliculus were included over a one-year period. Following caruncle excision, a 19 G needle is inserted through the medial canthal tissues into the nasal space. Nasal endoscopy confirms the accurate positioning in relation to the nasal anatomy. With the Holmium YAG laser, a tissue channel is fashioned around the guide needle through the structures of the lateral nasal wall to facilitate an accurate and secure placement of the Jones tube. The endoscopic, laser-assisted placement reduces the operating time to less than 20 minutes, minimizes tissue trauma and does not require the initial surgical steps of an open DCR procedure. There were 14 cases (87.5%) with securely retained tubes and two cases (12.5%) that required tube replacement. The advantage of the procedure is especially great in revision surgery where the ostium is opened through scar tissue. Nasal endoscopy with the assistance of the Holmium YAG laser offers simplicity and precision in the placement of Jones tubes. It minimizes tissue trauma and increases the surgical success rate.

  1. Evaluation of holmium laser versus cold knife in optical internal urethrotomy for the management of short segment urethral stricture.

    PubMed

    Jain, Sudhir Kumar; Kaza, Ram Chandra Murthy; Singh, Bipin Kumar

    2014-10-01

    SACHSE COLD KNIFE IS CONVENTIONALLY USED FOR OPTICAL INTERNAL URETHROTOMY INTENDED TO MANAGE URETHRAL STRICTURES AND HO: YAG laser is an alternative to it. The aim of this study was to evaluate the role of urethral stricture treatment outcomes, efficacy, and complications using cold knife and Ho: YAG (Holmium laser) for optical internal urethrotomy. In this prospective study included, 90 male patients age >18 years, with diagnosis of urethral stricture admitted for internal optical urethrotomy during April 2010 to March 2012. The patients were randomized into two groups containing 45 patients each using computer generated random number. In group A (Holmium group), internal urethrotomy was done with Holmium laser and in group B (Cold knife group) Sachse cold knife was used. Patients were followed up for 6 months after surgery in Out Patient Department on 15, 30 and 180 post-operative days. At each follow up visit physical examination, and uroflowmetry was performed along with noting complaints, if any. The peak flow rates (PFR) were compared between the two groups on each follow up. At 180 days (6 month interval) the difference between mean of PFR for Holmium and Cold knife group was statistically highly significant (P < 0.001). Complications were seen in 12.22% of cases. Both modalities are effective in providing immediate relief to patients with single and short segment (<2 cm long) urethral strictures but more sustained response was attained with Cold knife urethrotomy.

  2. Thulium fiber laser damage to the ureter

    NASA Astrophysics Data System (ADS)

    Wilson, Christopher R.; Hardy, Luke A.; Irby, Pierce B.; Fried, Nathaniel M.

    2015-07-01

    Our laboratory is studying experimental thulium fiber laser (TFL) as a potential alternative lithotripter to the clinical gold standard Holmium:YAG laser. Safety studies characterizing undesirable Holmium laser-induced damage to ureter tissue have been previously reported. Similarly, this study characterizes TFL induced ureter and stone basket damage. A TFL beam with pulse energy of 35 mJ, pulse duration of 500 μs, and pulse rates of 150-500 Hz was delivered through a 100-μm-core, low-OH, silica optical fiber to the porcine ureter wall, in vitro. Ureter perforation times were measured and gross, histological, and optical coherence tomography images of the ablation zone were acquired. TFL operation at 150, 300, and 500 Hz produced mean ureter perforation times of 7.9, 3.8, and 1.8 s, respectively. Collateral damage averaged 510, 370, and 310 μm. TFL mean perforation time exceeded 1 s at each setting, which is a greater safety margin than previously reported during Holmium laser ureter perforation studies.

  3. 2.05-μm Holmium-doped all-fiber continuous-wave laser at in-core diode-pumping at 1.125 μm

    NASA Astrophysics Data System (ADS)

    Kir'yanov, Alexander V.; Barmenkov, Yuri O.

    2017-08-01

    We report a Holmium-doped all-fiber laser oscillating in continuous-wave at 2.05 μm, at in-core pumping by a 1.125-μm laser diode. The active fibers employed are alumino-germano-silicate fibers doped with Ho3+ at concentrations of 1.2×1019 and 1.8×1019 cm-3. The laser is implemented in non-optimized Fabry-Perot cavity's geometry, composed of a couple of fiber Bragg gratings with reflectivity of 99 and 90%. When using the lower doped Holmium-doped fiber of proper length (1.4 m), low threshold ( 370 mW) and moderate slope efficiency ( 13%) of 2.05-μm lasing were obtained. High-brightness (laser line's width is 60 pm) and good noise-to-signal ratio (<0.006) are the laser's attractivities. In case of the heavier doped fiber of optimal length (1.2 m), the laser output (threshold of 430 mW, slope efficiency of 9%, output power of 9 mW, laser line's width of 110 pm, noise-to-signal ratio of <0.009) is worse, with a probable reason being deteriorating Ho3+ concentration effects.

  4. Holmium laser vs. conventional (cold knife) direct visual internal urethrotomy for short-segment bulbar urethral stricture: Outcome analysis.

    PubMed

    Jhanwar, Ankur; Kumar, Manoj; Sankhwar, Satya Narayan; Prakash, Gaurav

    2016-01-01

    Our goal was to analyze the outcome between holmium laser and cold knife direct visual internal urethrotomy (DVIU) for short-segment bulbar urethral stricture. We conducted a prospective study comprised of 112 male patients seen from June 2013 to December 2014. Inclusion criterion was short-segment bulbar urethral stricture (≤1.5cm). Exclusion criteria were prior intervention/urethroplasty, pan-anterior urethral strictures, posterior stenosis, urinary tract infection, and those who lost to followup. Patients were divided into two groups; Group A (n=58) included cold knife DVIU and group B (n=54) included holmium laser endourethrotomy patients. Patient followup included uroflowmetry at postoperative Day 3, as well as at three months and six months. Baseline demographics were comparable in both groups. A total of 107 patients met the inclusion criteria and five patients were excluded due to inadequate followup. Mean stricture length was 1.31 ± 0.252 cm (p=0.53) and 1.34 ± 0.251 cm in Groups A and B, respectively. Mean operating time in Group A was 16.3 ± 1.78 min and in Group B was 20.96 ± 2.23 min (p=0.0001). Five patients in Group A had bleeding after the procedure that was managed conservatively by applying perineal compression. Three patients in Group B had fluid extravasation postoperatively. Qmax (ml/s) was found to be statistically insignificant between the two groups at all followups. Both holmium laser and cold knife urethrotomy are safe and equally effective in treating short-segment bulbar urethral strictures in terms of outcome and complication rate. However, holmium laser requires more expertise and is a costly alternative.

  5. Laser fragmentation of foreign bodies in the urinary tract: an in vitro study and clinical application.

    PubMed

    Bedke, Jens; Kruck, Stephan; Schilling, David; Matter, Anton; Horstmann, Marcus; Sievert, Karl-Dietrich; Stenzl, Arnulf; Nagele, Udo

    2010-04-01

    Foreign bodies of the urinary tract represent a urologic emergency. First-line treatment is endoscopic removal, but this is often impeded by restricted space, especially in the urethra. We postulated that foreign objects could be fragmented by Holmium:YAG laser and investigated its effect on objects of varying composition. In a specially designed stage flushed with physiologic saline, medical and non-medical objects of differing composition and diameter were subjected to fragmentation by Holmium:YAG at powers of 18 and 30 W. In additional thermal experiments, 5,000 J was applied to differing volumes of 0.9% sodium chloride. Experiments were repeated ten times. With one exception (16 Ch silicon catheter) all medical objects were fragmented (latex urinary catheter, ureteral stents, and guidewires). Of non-medical objects (wood, steel, copper, graphite, and nylon) only copper wire was not amenable to laser dissection. These in vitro results were applied in two patients who presented with a pencil (wood and graphite) in the urethra or bladder. After Holmium:YAG laser fragmentation, the pencil could be removed by forceps each. Foreign objects in the urinary tract can be fragmented with a Holmium:YAG laser. When foreign bodies are too big for initial endoscopic extraction, the clinician should consider this technique as a reasonable and atraumatic option to avoid open surgery.

  6. Proteus mirabilis viability after lithotripsy of struvite calculi

    NASA Astrophysics Data System (ADS)

    Prabakharan, Sabitha; Teichman, Joel M. H.; Spore, Scott S.; Sabanegh, Edmund; Glickman, Randolph D.; McLean, Robert J. C.

    2000-05-01

    Urinary calculi composed of struvite harbor urease-producing bacteria within the stone. The photothermal mechanism of holmium:YAG lithotripsy is uniquely different than other lithotripsy devices. We postulated that bacterial viability of struvite calculi would be less for calculi fragmented with holmium:YAG irradiation compared to other lithotripsy devices. Human calculi of known struvite composition (greater than 90% magnesium ammonium phosphate hexahydrate) were incubated with Proteus mirabilis. Calculi were fragmented with no lithotripsy (controls), or shock wave, intracorporeal ultrasonic, electrohydraulic, pneumatic, holmium:YAG or pulsed dye laser lithotripsy. After lithotripsy, stone fragments were sonicated and specimens were serially plated for 48 hours at 38 C. Bacterial counts and the rate of bacterial sterilization were compared. Median bacterial counts (colony forming units per ml) were 8 X 106 in controls and 3 X 106 in shock wave, 3 X 107 in ultrasonic, 4 X 105 in electrohydraulic, 8 X 106 in pneumatic, 5 X 104 in holmium:YAG and 1 X 106 in pulsed dye laser lithotripsy, p less than 0.001. The rate of bacterial sterilization was 50% for holmium:YAG lithotripsy treated stones versus 0% for each of the other cohorts, p less than 0.01. P. mirabilis viability is less after holmium:YAG irradiation compared to other lithotripsy devices.

  7. Different lasers in the treatment of benign prostatic hyperplasia: a network meta-analysis

    PubMed Central

    Zhang, Xingming; Shen, Pengfei; He, Qiying; Yin, Xiaoxue; Chen, Zhibin; Gui, Haojun; Shu, Kunpeng; Tang, Qidun; Yang, Yaojing; Pan, Xiuyi; Wang, Jia; Chen, Ni; Zeng, Hao

    2016-01-01

    All available surgical treatments for benign prostatic hyperplasia (BPH) have their individual advantages or disadvantages. However, the lack of head-to-head studies comparing different surgeries makes it unavailable to conduct direct analysis. To compare the efficacy and safety among different lasers and transurethral resection of prostate (TURP) for BPH, randomized controlled trials were searched in MEDLINE, EMBASE, Cochrane library, WHO International Clinical Trial Registration Platform, and Clinical Trial.gov by 2015.5; and the effectiveness-, perioperation- and complication-related outcomes were assessed by network meta-analysis. 36 studies involving 3831 patients were included. Holmium laser through resection and enucleation had the best efficacy in maximum flow rate. Thulium laser through vapo-resection was superior in improving international prostate symptom score and holmium laser through enucleation was the best for post-voiding residual volume improvement. Diode laser through vaporization was the rapidest in removing postoperative indwelling catheter, while TURP was the longest. TURP required the longest hospitalization and thulium laser through vapo-resection was relatively shorter. Holmium and thulium lasers seem to be relatively better in surgical efficacy and safety, so that these two lasers might be preferred in selection of optimal laser surgery. Actually, more large-scale and high quality head-to-head RCTs are suggested to validate the conclusions. PMID:27009501

  8. 2.05 µm holmium-doped all-fiber laser diode-pumped at 1.125 µm

    NASA Astrophysics Data System (ADS)

    Kir'yanov, A. V.; Barmenkov, Y. O.; Villegas Garcia, I.

    2017-08-01

    We report a holmium-doped all-fiber laser oscillating at ~2.05 µm in continuous wave at direct in-core pumping by a 1.125 µm laser diode. Two types of home-made holmium-doped alumino-germano-silicate fiber (HDF), differentiated in the Ho3+ doping level, were fabricated to implement the laser, for revealing the effect of Ho3+ concentration upon the laser output. Firstly, the fibers were characterized thoroughly from the material and optical viewpoints. Then, laser action with both HDFs was assessed using the simplest Fabry-Perot cavity, assembled by a couple of spectrally adjusted fiber Bragg gratings, also made-in-house. In the best case, when using the lower-doped HDF of proper length (1.4 m), low threshold (~370 mW) and moderate slope efficiency (~13%) of ~2.05 µm lasing were obtained at 1.125 µm diode pumping. Long-term stability, high brightness, low noise, and purely CW operation are shown to be the laser’s attractive features. Yet, when utilizing the heavier-doped HDF, laser output is revealed to be overall worse, with a possible reason being the deteriorating Ho3+ concentration-related effects.

  9. [Current view and critic of alternatives to transurethral surgery of prostatic benign prostate].

    PubMed

    Rodríguez, José Vicente

    2003-11-01

    Critical update of transurethral surgery options based on the last decade most relevant bibliography. Comparative study between Incision/TUR of the prostate and alternative techniques, accordingly to data from 30 randomized studies and 28 clinical studies. We evaluate efficiency, retreatment index, morbidity, post operative number of days with catheter, anesthetic requirements, and cost. Data are expressed as percentages resulting from a differential formula in randomized studies and simple percentages or numeric expression for relevant clinical data. Efficiency: all alternative treatments show a symptomatic improvement (> 50%) similar to that achieved by transurethral surgery; post treatment flowmetry percentage increase is inferior in all alternatives except vaporization, holmium laser and prosthesis. Re-Treatment requirements: they were higher in all alternatives except the ablative ones (vaporization and holmium laser). Morbidity: all of them had an operative estimated blood loss inferior to TUR and similar to prostatic incision; contact laser and vaporization had more irritative symptoms than incision, and VLAP and TUMT more than TUR; TUMT and interstitial laser have a higher rate of post operative infection; all alternatives except the ablative ones had lower percentages of urethral stenosis and retrograde ejaculation. Number of days of catheter post operative: it was comparatively longer after vaporization and very long after VLAP, interstitial laser and TUMT. All treatments except TUNA and TUMT require the same anesthesia than transurethral surgery. The cost/benefit has not been sufficiently evaluated, but it is superior with holmium laser, contact laser and vaporization than with transurethral surgery. Based on study data we can accept holmium laser as a real alternative, TUMT in cases when surgery is questioned and intraprostatic prosthesis when it is not possible.

  10. Combination of Electronic Choledochoscopy and Holmium Laser Lithotripsy for Complicated Biliary Calculus Treatment: A New Exploration.

    PubMed

    Ni, Zhong-Kai; Jin, Hai-Min; Li, Xiao-Wen; Li, Ye; Huang, Hai

    2018-06-01

    The safety and efficacy of the combination of electronic choledochoscopy and holmium laser lithotripsy for complicated bile duct stones were assessed. In total, 20 patients participated in this study, which was conducted between 2012 and 2017. None of the patients were candidates for endoscopic retrograde cholangiopancreatography with stone extraction. Outcome measures included complete stone clearance and complications postprocedure. Mean stone size was 17±5.2 mm (8 to 30 mm) and mean number of stones was 1.7±1.3 (1 to 5). The mean number of laser sessions was 1.3±0.7 (1 to 4). A mean of 1.0 to 1.5 J/20 to 25 Hz was applied during laser lithotripsy sessions with a mean operative time of 67.8±24.8 minutes. The clearance rate of stone was 18/20 (90%). No mortality existed in this study; however, 1 patient developed acute pancreatitis. The combination of holmium laser lithotripsy and electronic choledochoscopy for complicated biliary calculi is safe, reliable, and minimally invasive and has low residual stone rate.

  11. High power operation of cladding pumped holmium-doped silica fibre lasers.

    PubMed

    Hemming, Alexander; Bennetts, Shayne; Simakov, Nikita; Davidson, Alan; Haub, John; Carter, Adrian

    2013-02-25

    We report the highest power operation of a resonantly cladding-pumped, holmium-doped silica fibre laser. The cladding pumped all-glass fibre utilises a fluorine doped glass layer to provide low loss cladding guidance of the 1.95 µm pump radiation. The operation of both single mode and large-mode area fibre lasers was demonstrated, with up to 140 W of output power achieved. A slope efficiency of 59% versus launched pump power was demonstrated. The free running emission was measured to be 2.12-2.15 µm demonstrating the potential of this architecture to address the long wavelength operation of silica based fibre lasers with high efficiency.

  12. Treatment of pulmonary diseases with Holmium:YAG laser

    NASA Astrophysics Data System (ADS)

    Zhang, Mei-Jue; Zhu, Jing; Zhang, Hui-Guo; Wang, Fu-Juan; Ke, Lin; Ma, Wei; Luo, Qun-Hua; Zhang, Yue-E.

    1998-11-01

    We report 5 cases of pulmonary disease treated with Holmium:YAG laser through fibrous bronchoscope. 1 inflammatory granuloma was cured after three times of treatment. Compared with conventional methods such as electrocautery and microwave treatment, laser has the merit of good hemostasis effect and quick recovery of the operation area. The other 4 patients who were suffered late lung cancer received 3-7 times of palliative treatment. After the treatment, the tumor tissues become smaller variably, and tact were unobstructed, symptoms of tract- obstructed obviously alleviated. We think that laser treatment has some practical significance in alleviating tract blocking of pulmonary diseases of late stage, and therefore raise the life quality.

  13. Re{sup 3+} : YAG laser ceramics: synthesis, optical properties and laser characteristics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bagayev, S N; Vatnik, S M; Vedin, I A

    2015-05-31

    Highly transparent yttrium aluminium garnet ceramics doped with holmium or ytterbium or neodymium are synthesised. The ceramics were made of a mixture of nanopowders synthesised by laser ablation. The structural and spectral characteristics of ceramics are studied. In the samples with holmium Ho{sup 3+} and neodymium Nd{sup 3+} ions, lasing was achieved with a slope efficiency of 40% and 35.3%, respectively; the maximum laser power exceeded 4 W. The internal absorption and scattering losses for 1% Nd : YAG ceramics are estimated to be 1.6 × 10{sup -2} cm{sup -1}. (extreme light fields and their applications)

  14. Cavitation bubble dynamics during thulium fiber laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Hardy, Luke A.; Kennedy, Joshua D.; Wilson, Christopher R.; Irby, Pierce B.; Fried, Nathaniel M.

    2016-02-01

    The Thulium fiber laser (TFL) is being explored for lithotripsy. TFL parameters differ from standard Holmium:YAG laser in several ways, including smaller fiber delivery, more strongly absorbed wavelength, low pulse energy/high pulse rate operation, and more uniform temporal pulse structure. High speed imaging of cavitation bubbles was performed at 105,000 fps and 10 μm spatial resolution to determine influence of these laser parameters on bubble formation. TFL was operated at 1908 nm with pulse energies of 5-75 mJ, and pulse durations of 200-1000 μs, delivered through 100-μm-core fiber. Cavitation bubble dynamics using Holmium laser at 2100 nm with pulse energies of 200-1000 mJ and pulse duration of 350 μs was studied, for comparison. A single, 500 μs TFL pulse produced a bubble stream extending 1090 +/- 110 μm from fiber tip, and maximum bubble diameters averaged 590 +/- 20 μm (n=4). These observations are consistent with previous studies which reported TFL ablation stallout at working distances < 1.0 mm. TFL bubble dimensions were five times smaller than for Holmium laser due to lower pulse energy, higher water absorption coefficient, and smaller fiber diameter used.

  15. Holmium laser enucleation versus laparoscopic simple prostatectomy for large adenomas.

    PubMed

    Juaneda, R; Thanigasalam, R; Rizk, J; Perrot, E; Theveniaud, P E; Baumert, H

    2016-01-01

    The aim of this study is to compare Holmium laser enucleation of the prostate with another minimally invasive technique, the laparoscopic simple prostatectomy. We compared outcomes of a series of 40 patients who underwent laparoscopic simple prostatectomy (n=20) with laser enucleation of the prostate (n=20) for large adenomas (>100 grams) at our institution. Study variables included operative time and catheterization time, hospital stay, pre- and post-operative International Prostate Symptom Score and maximum urinary flow rate, complications and economic evaluation. Statistical analyses were performed using the Student t test and Fisher test. There were no significant differences in patient age, preoperative prostatic size, operating time or specimen weight between the 2 groups. Duration of catheterization (P=.0008) and hospital stay (P<.0001) were significantly less in the laser group. Both groups showed a statistically significant improvement in functional variables at 3 months post operatively. The cost utility analysis for Holmium per case was 2589 euros versus 4706 per laparoscopic case. In the laser arm, 4 patients (20%) experienced complications according to the modified Clavien classification system versus 5 (25%) in the laparoscopic group (P>.99). Holmium enucleation of the prostate has similar short term functional results and complication rates compared to laparoscopic simple prostatectomy performed in large glands with the advantage of less catheterization time, lower economic costs and a reduced hospital stay. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Effects of the holmium laser on the human cornea: a preliminary study

    NASA Astrophysics Data System (ADS)

    Mueller, Linda J.; Tassignon, Marie J.; Trau, Rene; Pels, Liesbeth; Vrensen, Gijs F.

    1996-12-01

    Treatment of peripheral post-mortem human corneas with the Holmium laser in a ring pattern resulted in opaque spots. One pair of treated eyes was immediately processed for light and electron microscopy and three other treated eyes were preserved for 4 days in medium in order to compare direct and short-term effects of the Holmium laser. Cross as well as frontal light microscopical sections of all eyes revealed interconnecting bands between the spots. At the ultrastructural level the anterior corneal tissue within these spots was characterized by coagulation of cells and collagen and shoed either a dramatic distorting effect on the epithelium in the eyes processed immediately or a single layer of flattened multi-nucleolated epithelial cells having more than one nucleolus per nucleus in the eyes stored in medium. Furthermore, the spots showed disturbed Bowman's layer, destroyed keratocytes and collagen fibrils which were either coagulated or organized chaotically. The interconnecting bands contained alternating normal and coagulated collagen fibers. The rest of the cornea outside the spots had a normal appearance. In corneas stored in medium, both keratocytes and epithelial cells over the entire cornea exhibited accumulations of cytoplasmic fibrils and glycogen particles. These phenomena were not observed in non-preserved corneas, suggesting that the differences are due to preservation and not due to the laser treatment. It is concluded that morphological changes occur mainly in the treated peripheral cornea whereas the central untreated cornea remains unaffected,indicating that the Holmium laser is a reliable instrument to treat hypermetropic patients.

  17. Transurethral holmium-YAG laser lithotripsy for large symptomatic prostatic calculi: initial experience.

    PubMed

    Goyal, Neeraj Kumar; Goel, Apul; Sankhwar, Satyanarayan

    2013-08-01

    Symptomatic prostatic calculi are a rare clinical entity with wide range of management options, however, there is no agreement about the preferred method for treating these symptomatic calculi. In this study we describe our experience of transurethral management of symptomatic prostatic calculi using holmium-YAG laser lithotripsy. Patients with large, symptomatic prostatic stones managed by transurethral lithotripsy using holmium-YAG laser over 3-year duration were included in this retrospective study. Patients were evaluated for any underlying pathological condition and calculus load was determined by preoperative X-ray KUB film/CT scan. Urethrocystoscopy was performed using 30° cystoscope in lithotomy position under spinal anesthesia, followed by transurethral lithotripsy of prostatic calculi using a 550 μm laser fiber. Stone fragments were disintegrated using 100 W laser generators (VersaPulse PowerSuite 100 W, LUMENIS Surgical, CA). Larger stone fragments were retreived using Ellik's evacuator while smaller fragments got flushed under continuous irrigation. Five patients (median age 42 years) with large symptomatic prostatic calculi were operated using the described technique. Three patients had idiopathic stones while rest two had bulbar urethral stricture and neurogenic bladder, respectively. Median operative time was 62 min. All the patients were stone free at the end of procedure. Median duration of catheterization was 2 days. Significant improvement was observed in symptoms score and peak urinary flow and none of the patient had any complication. Transurethral management using holmium-YAG laser lithotripsy is a safe and highly effective, minimally invasive technique for managing symptomatic prostatic calculi of all sizes with no associated morbidity.

  18. The effect of frequency doubled double pulse Nd:YAG laser fiber proximity to the target stone on transient cavitation and acoustic emission.

    PubMed

    Fuh, Eric; Haleblian, George E; Norris, Regina D; Albala, W David M; Simmons, Neal; Zhong, Pei; Preminger, Glenn M

    2007-04-01

    Scant information has been published describing the effect of laser fiber distance from the stone target on the mechanism of calculus fragmentation. Using high speed photography and acoustic emission measurements we characterized the impact of laser fiber proximity on stone comminution. We evaluated the effect of laser fiber distance from the stone target on resultant cavitation bubble formation and shock wave generation. Stone fragmentation was assessed using a FREDDY (frequency doubled double pulse Nd:YAG) (World of Medicine, Orlando, Florida) laser and a holmium laser. The FREDDY laser was operated using a 420 microm fiber at an output energy of 120 and 160 mJ in single and double pulse settings, and a pulse repetition rate of 1 Hz. The holmium laser was operated using a 200 microm fiber at an output energy of 1 to 3 J and a pulse repetition rate of 1 Hz. The surface of a 1 cm square BegoStone (Bego, Bremen, Germany) attached to an X-Y-Z translational stage was aligned perpendicular to the laser fiber, which was immersed in a Lucite tank filled with water at room temperature. An Imacon 200 high speed camera was used to capture transient cavitation bubbles at a framing rate of up to 1,000,000 frames per second. Acoustic emission signals associated with shock waves generated during the rapid expansion and collapse of the cavitation bubble were measured using a 1 MHz focused ultrasound transducer. At laser fiber distances of 3.0 mm or less cavitation bubbles and shock waves were observed with the FREDDY laser. In contrast to the holmium laser, the bubble size and shock wave intensity of the FREDDY laser was inversely related to the fiber-to-stone distance over the range tested (0.5 to 3.0 mm). While bubble size was noted to increase with a larger stone-to-fiber distance using the holmium laser, to consistently generate cavitation bubbles and shock waves using the FREDDY laser the laser fiber should be operated within 3.0 mm of the target stone. These findings have significant implications during clinical laser stone fragmentation.

  19. In vitro and in vivo comparison of optics and performance of a distal sensor ureteroscope versus a standard fiberoptic ureteroscope.

    PubMed

    Lusch, Achim; Abdelshehid, Corollos; Hidas, Guy; Osann, Kathryn E; Okhunov, Zhamshid; McDougall, Elspeth; Landman, Jaime

    2013-07-01

    Recent advances in distal sensor technologies have made distal sensor ureteroscopes both commercially and technically feasible. We evaluated performance characteristics and optics of a new generation distal sensor Flex-X(C) (X(C)) and a standard flexible fiberoptic ureteroscope Flex-X(2) (X(2)), both from Karl Storz, Tuttlingen, Germany. The ureteroscopes were compared for active deflection, irrigation flow, and optical characteristics. Each ureteroscope was evaluated with an empty working channel and with various accessories. Optical characteristics (resolution, grayscale imaging, and color representation) were measured using United States Air Force test targets. We digitally recorded a renal porcine ureteroscopy and laser ablation of a stone with the X(2) and with the X(C). Edited footage of the recorded procedure was shown to different expert surgeons (n=8) on a high-definition monitor for evaluation by questionnaire for image quality and performance. The X(C) had a higher resolution than the X(2) at 20 and 10 mm 3.17 lines/mm vs 1.41 lines/mm, 10.1 vs 3.56, respectively (P=0.003, P=0.002). Color representation was better in the X(C). There was no difference in contrast quality between the two ureteroscopes. For each individual ureteroscope, the upward deflection was greater than the downward deflection both with and without accessories. When compared with the X(2), the X(C) manifested superior deflection and flow (P<0.0005, P<0.05) with and without accessory present in the working channel. Observers deemed the distal sensor ureteroscope superior in visualization in clear and bloody fields, as well as for illumination (P=0.0005, P=0.002, P=0.0125). In this in vitro and porcine evaluation, the distal sensor ureteroscope provided significantly improved resolution, color representation, and visualization in the upper urinary tract compared with a standard fiberoptic ureteroscope. The overall deflection was also better in the X(C), and deflection as well as flow rate was less impaired by the various accessories.

  20. Bubble formation during pulsed laser ablation: mechanism and implications

    NASA Astrophysics Data System (ADS)

    van Leeuwen, Ton G. J. M.; Jansen, E. Duco; Motamedi, Massoud; Welch, Ashley J.; Borst, Cornelius

    1993-07-01

    Holmium ((lambda) equals 2.09 micrometers ) and excimer ((lambda) equals 308 nm) lasers are used for ablation of tissue. In a previous study it was demonstrated that both excimer and holmium laser pulses produce fast expanding and collapsing vapor bubbles. To investigate whether the excimer induced bubble is caused by vaporization of water, the threshold fluence for bubble formation at a bare fiber tip in water was compared between the excimer laser (pulse length 115 ns) and the Q-switched and free-running holmium lasers (pulse length 1 microsecond(s) to 250 microsecond(s) , respectively). To induce bubble formation by excimer laser light in water, the absorber oxybuprocaine-hydrochloride (OBP-HCl) was added to the water. Fast flash photography was used to measure the threshold fluence as a function of the water temperature (6 - 90 degree(s)C) at environmental pressure. The ultraviolet excimer laser light is strongly absorbed by blood. Therefore, to document the implications of bubble formation at fluences above the tissue ablation threshold, excimer laser pulses were delivered in vitro in hemoglobin solution and in vivo in the femoral artery of the rabbit. We conclude that the principal content of the fast bubble induced by a 308 nm excimer laser pulse is water vapor. Therefore, delivery of excimer laser pulses in a water or blood environment will cause fast expanding water vapor bubbles, which may induce mechanical damage to adjacent tissue.

  1. Stone retropulsion during holmium:YAG lithotripsy.

    PubMed

    Lee, Ho; Ryan, R Tres; Teichman, Joel M H; Kim, Jeehyun; Choi, Bernard; Arakeri, Navanit V; Welch, A J

    2003-03-01

    We modeled retropulsion during holmium:YAG lithotripsy on the conservation of momentum, whereby the force of ejected fragment debris off of the calculous surface should equal the force of retropulsion displacing the stone. We tested the hypothesis that retropulsion occurs as a result of ejected stone debris. Uniform calculous phantoms were irradiated with holmium:YAG energy in air and in water. Optical fiber diameter and pulse energy were varied. Motion of the phantom was monitored with high speed video imaging. Laser induced crater volume and geometry were characterized by optical coherence tomography. To determine the direction of plume laser burn paper was irradiated at various incident angles. Retropulsion was greater for phantoms irradiated in air versus water. Retropulsion increased as fiber diameter increased and as pulse energy increased (p <0.001). Crater volumes increased as pulse energy increased (p <0.05) and generally increased as fiber diameter increased. Crater geometry was wide and shallow for larger fibers, and narrow and deeper for smaller fibers. The ejected plume propagated in the direction normal to the burn paper surface regardless of the laser incident angle. Retropulsion increases as pulse energy and optical fiber diameter increase. Vector analysis of the ejected plume and crater geometry explains increased retropulsion using larger optical fibers. Holmium:YAG lithotripsy should be performed with small optical fibers to limit retropulsion.

  2. Holmium laser enucleation of the prostate combined with electrocautery resection: the mushroom technique.

    PubMed

    Hochreiter, Werner W; Thalmann, George N; Burkhard, Fiona C; Studer, Urs E

    2002-10-01

    The holmium laser allows bloodless enucleation of the prostate. A problem is how to remove a whole enucleated, free floating, large prostatic lobe from the bladder. A mechanical morcellator has been used to achieve tissue fragmentation but aspiration of and damage to the bladder wall are risks. Using the mushroom technique holmium laser enucleation and electrocautery resection can be combined without compromising the bloodless advantages of the laser procedure. We treated 156 patients with benign prostatic hyperplasia using a holmium laser with the mushroom technique. Preoperatively all patients were assessed using the International Prostate Symptom Score, maximum urine flow, ultrasound estimation of prostate volume and post-void residual urine, and pressure flow study. Laser enucleation of the prostatic lobes was performed at 66 W. Instead of releasing the lobes into the bladder they were left attached at the bladder neck by a narrow mushroom-like pedicle. At that point the vascular supply was almost completely interrupted and the lobes could easily be electroresected into small pieces without bleeding. Patients were followed 6, 12 and 24 months after the procedure. No patient had significant blood loss or signs of the transurethral resection syndrome. A total of 19 patients were treated while under oral anticoagulation without major bleeding problems. Complete followup was available on 125 patients. Median baseline International Prostate Symptom Score decreased from 20 to 3 at 6 months (p <0.05) and remained stable at 12 and 24 months. Median maximum urine flow increased from 8 to 20 ml. per second at 6, 12 and 24 months (p <0.05). Median baseline post-void residual urine decreased from 190 to 30 ml. at 6 months (p <0.05) and remained low at 20 and 30 ml. at 12 and 24 months, respectively. Urodynamic evaluation preoperatively and 6 months postoperatively was available in 83 cases. Relief of obstruction was documented with a statistically significant decrease in median detrusor pressure at maximum urine flow from 87 to 48 cm. water (p <0.05). Combining holmium laser enucleation and prostate electroresection with the mushroom technique is safe, efficient and bloodless surgical treatment for benign prostatic hyperplasia with sustained relief of obstruction. With this technique there is no need for additional devices, such as a mechanical tissue morcellator.

  3. Photothermal laser lithotripsy of uric acid calculi: clinical assessment of the effects of cyanide production

    NASA Astrophysics Data System (ADS)

    Teichman, Joel M. H.; Champion, Paolo C.; Glickman, Randolph D.; Wollin, Timothy A.; Denstedt, John D.

    1999-06-01

    The mechanism of holmium:YAG lithotripsy is photothermal. Holmium:YAG lithotripsy of uric acid calculi produces cyanide, which is a known, thermal decomposition produce of uric acid. we review our experience with holmium:YAG lithotripsy of uric acid to determine if there is any clinical evidence of cyanide toxicity. A retrospective analysis of all of our cases of holmium:YAG lithotripsy of uric acid calculi was done. Anesthetic and postoperative data were reviewed. A total of 18 patients with uric acid calculi were tread with holmium:YAG lithotripsy by urethroscopy (5), retrograde nephroscopy (2), percutaneous nephrolithotomy (5) or cystolithotripsy (6). Total holmium:YAG irradiation ranged from 1.2 to 331 kJ. No patient had evidence of increased end-tidal carbon dioxide, change sin electrocardiogram or significant decrease in postoperative serum bicarbonate. An 84 year old woman had decreased diastolic pressure of 30 mm Hg while under general anesthesia. No cyanide related neurologic, cardiac or respiratory complications were noted. These data suggest no significant cyanide toxicity from holmium:YAG lithotripsy or uric acid calculi in typical clinical settings. More specific studies in animals are warranted to characterize the risk.

  4. Use of the holmium:YAG laser for percutaneous photothermal ablation of cervical invertebral disks in dogs

    NASA Astrophysics Data System (ADS)

    Rochat, Mark; Henry, George A.; Campbell, Gregory A.; Stair, Ernest L.; Bartels, Kenneth E.; Dickey, Tom

    1999-06-01

    Holmium:YAG laser ablation of thoracolumbar disks in dogs has been shown to be an effective alternative to standard surgical fenestration techniques. Our hypothesis was the Holmium:YAG laser could be equally effective and safe when used to ablate cervical intervertebral disks. Six normal chondrodystrophoid breed dogs were used. A sterile, cleaved, 320 micrometers , low-OH quartz optical fiber was inserted into each needle and the laser activated for 40 s at 2 W mean power and a 15 Hz pulse repetition rate for a total of 80 J. Dogs were observed in pain, neurological deficits, or other complications for 24 weeks. At 24 weeks, dogs were euthanatized and cervical disks collected and placed in 10 percent neutral buffered formalin. Disks were decalcified, sectioned at 5 micrometers , and stained with H and E. No problems were encountered during the procedure except occasional difficulties passing the needle by the shoulder to enter the C6-7 disk space. No complications, including neurologic deficits or pain were observe during the 24 weeks. Histologic examination revealed varying degrees of necrosis and defects created in the nucleus pulposus by laser irradiation. In some instances there was evidence of mild adjacent annular and bony thermal injury. On the basis of these result, the Ho:YAG laser appears to be a safe and efficacious method for ablation of canine cervical disks.

  5. Acoustic transient generation in pulsed holmium laser ablation under water

    NASA Astrophysics Data System (ADS)

    Asshauer, Thomas; Rink, Klaus; Delacretaz, Guy P.; Salathe, Rene-Paul; Gerber, Bruno E.; Frenz, Martin; Pratisto, Hans; Ith, Michael; Romano, Valerio; Weber, Heinz P.

    1994-08-01

    In this study the role of acoustical transients during pulsed holmium laser ablation is addressed. For this the collapse of cavitation bubbles generated by 2.12 micrometers Cr:Tm:Ho:YAG laser pulses delivered via a fiber in water is investigated. Multiple consecutive collapses of a single bubble generating acoustic transients are documented. Pulse durations are varied from 130 - 230 microsecond(s) and pulse energies from 20 - 800 mJ. Fiber diameters of 400 and 600 micrometers are used. The bubble collapse behavior is observed by time resolved fast flash photography with 1 microsecond(s) strobe lamp or 5 ns 1064 nm Nd:YAG laser illumination. A PVDF needle probe transducer is used to observe acoustic transients and measure their pressure amplitudes. Under certain conditions, at the end of the collapse phase the bubbles emit spherical acoustic transients of up to several hundred bars amplitude. After the first collapse up to two rebounds leading to further acoustic transient emissions are observed. Bubbles generated near a solid surface under water are attracted towards the surface during their development. The final phase of the collapse generating the acoustic transients takes place directly on the surface, exposing it to maximum pressure amplitudes. Our results indicate a possible mechanism of unwanted tissue damage during holmium laser application in a liquid environment as in arthroscopy or angioplasty that may set limits to the choice of laser pulse duration and energies.

  6. Cavitation effect of holmium laser pulse applied to ablation of hard tissue underwater.

    PubMed

    Lü, Tao; Xiao, Qing; Xia, Danqing; Ruan, Kai; Li, Zhengjia

    2010-01-01

    To overcome the inconsecutive drawback of shadow and schlieren photography, the complete dynamics of cavitation bubble oscillation or ablation products induced by a single holmium laser pulse [2.12 microm, 300 micros (FWHM)] transmitted in different core diameter (200, 400, and 600 microm) fibers is recorded by means of high-speed photography. Consecutive images from high-speed cameras can stand for the true and complete process of laser-water or laser-tissue interaction. Both laser pulse energy and fiber diameter determine cavitation bubble size, which further determines acoustic transient amplitudes. Based on the pictures taken by high-speed camera and scanned by an optical coherent microscopy (OCM) system, it is easily seen that the liquid layer at the distal end of the fiber plays an important role during the process of laser-tissue interaction, which can increase ablation efficiency, decrease heat side effects, and reduce cost.

  7. Miniature ureteroscope tip designs for use in thulium fiber laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Kennedy, Joshua D.; Wilson, Christopher R.; Irby, Pierce B.; Fried, Nathaniel M.

    2017-02-01

    A miniature ureteroscope has the potential to eliminate need for full anesthesia and dilation, increase comfort and safety of laser lithotripsy via ureteroscopy, and reduce hospital costs via an office based procedure. A prototype, 4.5 Fr (1.5-mm-OD), five channel ureteroscope tip was developed, housing a 200-μm-ID central channel for insertion of small, 100-μm-core fibers and four surrounding channels, each with 510-μm-ID for instrumentation, irrigation, imaging, and illumination, respectively. Common urological instruments (including fibers, guidewires, and stone baskets) were inserted through tip's working channels to demonstrate feasibility. Low irrigation rates were measured, revealing a need for manual pump-assisted irrigation. Imaging was conducted using 3k, 6k, and 10k pixel miniature flexible endoscopes with 0.4, 0.6, and 0.9 mm outer diameters, respectively. The 3k pixel endoscope with integrated illumination was inserted through the prototype unimpeded, and successfully demonstrated ability to differentiate between hard tissues (e.g. kidney stones) and soft tissues (e.g. ureter wall), for visibility and safety during potential clinical application. Based on both image quality and instrument diameter, the 6k pixel endoscope provided an optimal solution for miniature ureteroscopy.

  8. Impact of holmium fibre laser radiation (λ = 2.1 μm) on the spinal cord dura mater and adipose tissue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filatova, S A; Kamynin, V A; Ryabova, A V

    The impact of holmium fibre laser radiation on the samples of biologic tissues (dura mater of spinal cord and adipose tissue with interlayers of muscle) is studied. The experimental results are evaluated by the size of carbonisation and coagulation necrosis zones. The experiment shows that in the case of irradiation of the spinal cord dura mater samples the size of carbonisation and coagulation necrosis zones is insignificant. In the adipose tissue the carbonisation zone is also insignificant, but the region of cellular structure disturbance is large. In the muscle tissue the situation is opposite. The cw laser operation provides clinicallymore » acceptable degree of destruction in tissue samples with a minimal carbonisation zone. (laser applications in medicine)« less

  9. Rare complication of needleless mini-sling procedure: Case report.

    PubMed

    Karalar, Mustafa; Keles, Ibrahim; Unlu, Serdar; Sarici, Hasmet; Kose, Mesut; Ay, Cemil

    2017-01-01

    The mini-sling procedure is a widely used, minimally invasive treatment for stress urinary incontinence. While bladder perforation and stone formation over the mesh is not an expected complication of the mini-sling procedure, in this case, we report on the management of bladder calculi formed over the mesh, which was passed through the bladder while applying the mini-sling procedure, and was eventually removed using holmium laser. Performing cystoscopy in patients with irritative and obstructive symptoms after the sling procedure will help confirm bladder perforation, and an endoscopic approach using holmium laser is an effective treatment.

  10. Treatment of giant pyogenic granuloma with the Nd/YAG holmium laser: a case report.

    PubMed

    Yang, Chunjun; Liu, Shengxiu

    2013-08-01

    Pyogenic granuloma (PG) is a common vascular tumor that can be treated using various means. However, some large lesions and those located on some difficult-to-treat body sites may represent a formidable selection to the clinician because of the residual pain after treatment, difficulties in surgical excision at one trial and covering with one dressing, and the risk of sequelae. We report a successful treatment of such a giant lesion that arises in the scar which was left because of port wine stain, using a Nd/YAG holmium pulsed dye laser.

  11. Could titanium oxide coating from a sol-gel process make stone baskets more resistant to laser radiation at 2.1 μm?

    PubMed

    Cordes, Jens; Nguyen, Felix; Heidenau, Frank; Jocham, Dieter

    2012-10-19

    Stone baskets could be easily destroyed by Holmium:YAG-laser at an endourologic treatment, with respect to this, we try to improve the resistance by coating them with a titanium oxide layer. The layer was established by a sol-gel-process. Six new baskets (Equadus, Opi Med, Ettlingen, Germany) were used: 1.8 Ch. with 4 wires (diameter 0.127 mm). Three baskets were coated with a layer of titanium oxide established by a sol-gel process at the BioCerEntwicklungs GmbH in Bayreuth (~100 nanometres thickness). The lithotripter was a Holmium:YAG laser (Auriga XL, Starmedtec, Starnberg, Germany). 10 uncoated and 10 coated wires were tested with 610 mJ (the minimal clinical setting) and 2 uncoated and 2 coated wires were tested with 110 mJ. The wires were locked in a special holding instrument under water and the laser incident angle was 90°. The endpoint was gross visible damage to the wire and loss of electric conduction. Only two coated wires resisted two pulses (one in the 610 mJ and one in the 110 mJ setting). All other wires were destroyed after one pulse. This was the first attempt at making stone baskets more resistant to a Holmium:YAG laser beam. Titanium oxide deposited by a sol-gel-process on a titanium-nickel alloy did not result in better resistance to laser injuries.

  12. Combining ultrasonography and noncontrast helical computerized tomography to evaluate Holmium laser lithotripsy

    PubMed Central

    Mi, Jia; Li, Jie; Zhang, Qinglu; Wang, Xing; Liu, Hongyu; Cao, Yanlu; Liu, Xiaoyan; Sun, Xiao; Shang, Mengmeng; Liu, Qing

    2016-01-01

    Abstract The purpose of the study was to establish a mathematical model for correlating the combination of ultrasonography and noncontrast helical computerized tomography (NCHCT) with the total energy of Holmium laser lithotripsy. In this study, from March 2013 to February 2014, 180 patients with single urinary calculus were examined using ultrasonography and NCHCT before Holmium laser lithotripsy. The calculus location and size, acoustic shadowing (AS) level, twinkling artifact intensity (TAI), and CT value were all documented. The total energy of lithotripsy (TEL) and the calculus composition were also recorded postoperatively. Data were analyzed using Spearman's rank correlation coefficient, with the SPSS 17.0 software package. Multiple linear regression was also used for further statistical analysis. A significant difference in the TEL was observed between renal calculi and ureteral calculi (r = –0.565, P < 0.001), and there was a strong correlation between the calculus size and the TEL (r = 0.675, P < 0.001). The difference in the TEL between the calculi with and without AS was highly significant (r = 0.325, P < 0.001). The CT value of the calculi was significantly correlated with the TEL (r = 0.386, P < 0.001). A correlation between the TAI and TEL was also observed (r = 0.391, P < 0.001). Multiple linear regression analysis revealed that the location, size, and TAI of the calculi were related to the TEL, and the location and size were statistically significant predictors (adjusted r2 = 0.498, P < 0.001). A mathematical model correlating the combination of ultrasonography and NCHCT with TEL was established; this model may provide a foundation to guide the use of energy in Holmium laser lithotripsy. The TEL can be estimated by the location, size, and TAI of the calculus. PMID:27930563

  13. Thulium fiber laser lithotripsy using small spherical distal fiber tips

    NASA Astrophysics Data System (ADS)

    Wilson, Christopher R.; Hardy, Luke A.; Kennedy, Joshua D.; Irby, Pierce B.; Fried, Nathaniel M.

    2016-02-01

    This study tests a 100-μm-core fiber with 300-μm-diameter ball tip during Thulium fiber laser (TFL) lithotripsy. The TFL was operated at 1908 nm wavelength with 35-mJ pulse energy, 500-μs pulse duration, and 300-Hz pulse rate. Calcium oxalate/phosphate stone samples were weighed, laser procedure times measured, and ablation rates calculated for ball tip fibers, with comparison to bare tip fibers. Photographs of ball tips were taken before and after each procedure to observe ball tip degradation and determine number of procedures completed before need to replace fiber. Saline irrigation rates and ureteroscope deflection were measured with and without TFL fiber present. There was no statistical difference (P > 0.05) between stone ablation rates for single-use ball tip fiber (1.3 +/- 0.4 mg/s) (n=10), multiple-use ball tip fiber (1.3 +/- 0.5 mg/s) (n=44), and conventional single-use bare tip fibers (1.3 +/- 0.2 mg/s) (n=10). Ball tip durability varied widely, but fibers averaged > 4 stone procedures before decline in stone ablation rates due to mechanical damage at front surface of ball tip. The small fiber diameter did not impact ureteroscope deflection or saline flow rates. The miniature ball tip fiber may provide a cost-effective design for safe fiber insertion through the ureteroscope working channel and the ureter without risk of scope damage or tissue perforation, and without compromising stone ablation efficiency during TFL ablation of kidney stones.

  14. Results of retrograde intrarenal surgery in the treatment of renal stones greater than 2 cm.

    PubMed

    Palmero, J L; Castelló, A; Miralles, J; Nuño de La Rosa, I; Garau, C; Pastor, J C

    2014-05-01

    To analyze the results of retrograde intrarenal surgery (RIRS) in patients with ≥2 cm stones treated in our center. A retrospective review of 106 patients with renal calculi underwent RIRS ≥2 cm (period January 2009-December 2011). The procedures were performed under general anesthesia as a source of fragmentation using the holmium laser (30 W Litho Quantasystem) and flexible ureteroscopes (X2 Flex Storz, Olympus P5) through ureteral access sheaths. It discusses demographic variables (age, medical history, antiplatelet or anticoagulant treatment, treatment of urolithiasis, BMI, ASA), treated stones variables (size, number, Hounsfield units, biochemical composition) and intra-and postoperative variables (operative time, number of pulses, hospital stay, complications) with the completion of a descriptive analysis of the same. To define our results we consider success to the complete absence of fragments or residual <5 mm posterior imaging tests. The mean stone size was 2.46 cm treated, being the only stone in 87.7% of cases. The most frequent location was the renal pelvis stones (44%) followed by the lower calyx (39%). The postoperative complication rate was 6.7%, with all of little relevance. The success rate with a single procedure was 79.4% to 94.1% with retreatment. RIRS is a valid alternative for the treatment of kidney stones ≥2 cm for its high success rate and few complications if performed in specialized centers. Copyright © 2013 AEU. Published by Elsevier Espana. All rights reserved.

  15. Use of the Moses Technology to Improve Holmium Laser Lithotripsy Outcomes: A Preclinical Study.

    PubMed

    Elhilali, Mostafa M; Badaan, Shadie; Ibrahim, Ahmed; Andonian, Sero

    2017-06-01

    To evaluate in vitro and in vivo effects of Moses technology in Holmium laser and to compare it with the Regular mode in terms of lithotripsy efficiency and laser-tissue interactions. The Lumenis ® Pulse™ P120H holmium laser system together with Moses D/F/L fibers were used to compare the Regular mode with the Moses modes in stone retropulsion by using a high-speed camera, and stone ablation efficiency. In addition, a porcine ureteroscopy model was used to assess stone fragmentation and dusting as well as laser-tissue interaction with the ureteral wall. After a laser pulse, in vitro stone displacement experiments showed a significant reduction in retropulsion when using the Moses mode. The stone movement was reduced by 50 times at 0.8 J and 10 Hz (p < 0.01). The pronounced reduction of retropulsion in the Moses mode was clearly observed during fragmentation setting (high energy) and dusting (low energy, high Hz). In addition, stone fragmentation tests showed that the Moses modes resulted in a significantly higher ablation volume when compared with the Regular mode (160% higher; p < 0.001). In vivo assessment also supported the reduction in retropulsion when treating stones in the porcine kidney. Histological analysis of the porcine ureter after direct lasing in the Moses mode suggested less damage than in the Regular mode. The Moses technology resulted in more efficient laser lithotripsy, in addition to significantly reduced stone retropulsion, and displayed a margin of safety that may result in a shorter procedural time and safer lithotripsy.

  16. Pneumatic versus laser ureteroscopic lithotripsy: a comparison of initial outcomes and cost.

    PubMed

    Demir, Aslan; Karadağ, Mert Ali; Ceçen, Kurşat; Uslu, Mehmet; Arslan, Omer Erkam

    2014-11-01

    To audit the cost of laser versus pneumatic semirigid ureteroscopic lithotripsy and to analyze their relative initial outcomes and cost. Hundred and eighty-seven patients who underwent semirigid ureteroscopic lithotripsy were analyzed retrospectively in terms of age and sex of the patients; location and size of the stones; the type of probe and ancillary equipment such as guide wire, basket catheter, JJ stent requirements; irrigation amount; operation time; the cost of the anesthesia and further treatments such as a JJ stent removal operation and shock wave lithotripsy requirements and their costs. Two groups were formed based on this type of lithotripters, pneumatic and laser lithotripsy. Operation times (min.) in terms of the stone size, for stones <100 and >100 mm(2) were 20.75 ± 10.78 and 25.82 ± 14.23, respectively (p = 0.007). Operation times for the pneumatic and laser groups were 33.05 ± 11.36 and 15.25 ± 6.14, respectively (p < 0.05).The stone-free rates for pneumatic and laser groups were 89.6 % (n = 69) and 98.2 % (n = 108), respectively (p = 0.01). The mean cost of the operations for each of the study groups was 261.5 ± 66.13 and 311.7 ± 51.97 US$, respectively (p = 0.001). The mean cost in terms of the stone size, for stones <100 and >100 mm(2), was 272.86 ± 53.05 and 323.71 ± 66.88 US$, respectively (p = 0.01). It seems that usage of laser lithotripsy (LL) in patients with ureteral stones is more effective than pneumatic lithotripsy (PL) in terms of operation time and SF rate. On the other hand, the mean cost of LL seems to be more expensive than PL. Urologists should think these parameters before the choice of these two treatment modalities. The higher the effectiveness, the greater the cost.

  17. Acute and chronic response of meniscal fibrocartilage to holmium:YAG laser irradiation

    NASA Astrophysics Data System (ADS)

    Horan, Patrick J.; Popovic, Neven A.; Islinger, Richard B.; Kuklo, Timothy R.; Dick, Edward J.

    1997-05-01

    The acute and chronic (10 week) histological effects of the holmium:YAG laser during partial meniscectomy in an in vivo rabbit model were investigated. Twenty-four adult male New Zealand rabbits underwent bilateral parapatellar medial knee arthrotomies. In the right knee, a partial medial meniscectomy was done through the avascular zone using a standard surgical blade. In the left knee, an anatomically similar partial medial meniscectomy was performed using a Ho:YAG laser (Coherent, USA). This study indicates that the laser creates two zones of damage in the meniscal fibrocartilage and that the zone of thermal change may act as a barrier to healing. The zone of thermal change which is eventually debrided was thought at the time of surgery to be viable. In the laser cut menisci, the synovium appears to have greater inflammation early and to be equivalent with the scalpel cut after three weeks. At all time periods there appeared more cellular damage in the laser specimens.

  18. Holmium-doped fluorotellurite microstructured fibers for 2.1 μm lasing.

    PubMed

    Yao, Chuanfei; He, Chunfeng; Jia, Zhixu; Wang, Shunbin; Qin, Guanshi; Ohishi, Yasutake; Qin, Weiping

    2015-10-15

    Holmium (Ho3+)-doped fluorotellurite microstructured fibers based on TeO2-BaF2-Y2O3 glasses are fabricated by using a rod-in-tube method. By using a 1.992 μm fiber laser as the pump source, lasing at 2.077 μm is obtained from a 27 cm long Ho3+-doped fluorotellurite microstructured fiber. The maximum unsaturated power is about 161 mW and the corresponding slope efficiency is up to 67.4%. The influence of fiber length on lasing at 2.1 μm is also investigated. Our results show that Ho3+-doped fluorotellurite microstructured fibers are promising gain media for 2.1 μm laser applications.

  19. Single-Frequency Narrow Linewidth 2 Micron Fiber Laser

    NASA Technical Reports Server (NTRS)

    Jiang, Shibin (Inventor); Spiegelberg, Christine (Inventor); Luo, Tao (Inventor)

    2006-01-01

    A compact single frequency, single-mode 2 .mu.m fiber laser with narrow linewidth, <100 kHz and preferably <100 kHz, is formed with a low phonon energy glass doped with triply ionized rare-earth thulium and/or holmium oxide and fiber gratings formed in sections of passive silica fiber and fused thereto. Formation of the gratings in passive silica fiber both facilitates splicing to other optical components and reduces noise thus improving linewidth. An increased doping concentration of 0.5 to 15 wt. % for thulium, holmium or mixtures thereof produces adequate gain, hence output power levels for fiber lengths less than 5 cm and preferably less than 3 cm to enable single-frequency operation.

  20. Therapeutic applications of lasers in urology: an update.

    PubMed

    Fried, Nathaniel M

    2006-01-01

    There has been renewed interest in the use of lasers for minimally invasive treatment of urologic diseases in recent years. The introduction of more compact, higher power, less expensive and more user-friendly solid-state lasers, such as the holmium:yttrium-aluminum-garnet (YAG), frequency-doubled neodymium:YAG and diode lasers has made the technology more attractive for clinical use. The availability of small, flexible, biocompatible, inexpensive and disposable silica optical fiber delivery systems for use in flexible endoscopes has also promoted the development of new laser procedures. The holmium:YAG laser is currently the workhorse laser in urology since it can be used for multiple soft- and hard-tissue applications, including laser lithotripsy, benign prostate hyperplasia, bladder tumors and strictures. More recently, higher power potassium-titanyl-phosphate lasers have been introduced and show promise for the treatment of benign prostatic hyperplasia. On the horizon, newer and more effective photosensitizing drugs are being tested for potential use in photodynamic therapy of bladder and prostate cancer. Additionally, new experimental lasers such as the erbium:YAG, Thulium and Thulium fiber lasers, may provide more precise incision of soft tissues, more efficient laser lithotripsy and more rapid prostate ablation. This review provides an update on the most important new clinical and experimental therapeutic applications of lasers in urology over the past 5 years.

  1. Laboratory investigation of the efficacy of holmium:YAG laser irradiation in removing intracanal debris

    NASA Astrophysics Data System (ADS)

    Nuebler-Moritz, Michael; Gutknecht, Norbert; Sailer, Hermann F.; Hering, Peter; Prettl, Wilhelm

    1997-05-01

    Current endodontic therapy involves debridement and disinfection of the root canal by means of mechanical instrumentation and chemical irrigation. However, several studies have shown that these techniques fail to achieve complete cleansing. Recently, lasers have been suggested for use within root canals. This study was conducted to determine the efficacy of Holmium:YAG laser irradiation in removing intracanal debris and smear layer. Root canal surfaces of freshly-extracted human teeth were exposed to pulsed Ho:YAG laser radiation. Subsequently, laser induced structural changes were investigated using scanning electron microscopy. Temperature measurements during irradiation were performed by means of thermocouples. The result of this survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment modalities. However, limitations exist with regard to circumscribed and well-quantified irradiation of root canal surfaces, due to the lack of perpendicular delivery of the laser beam. Additional studies will be required to develop suitable optical transmission systems, in order to achieve complete cleansing and to avoid damage to the periradicular tissues, respectively.

  2. Treatment for residual stones using flexible ureteroscopy and holmium laser lithotripsy after the management of complex calculi with single-tract percutaneous nephrolithotomy.

    PubMed

    Chen, L; Sha, M-L; Li, D; Zhuo, J; Jiang, C-Y; Zhu, Y-P; Xia, S-J; Lu, J; Shao, Y

    2017-04-01

    This study validated the effectiveness and safety of the treatment for residual stones using flexible ureteroscopy (fURS) and holmium laser (0.6-1.2 J, 20-30 Hz) lithotripsy via a fiber with a 200-μm core diameter and 0.22 numerical aperture (NA) after the management of complex calculi with single-tract percutaneous nephrolithotomy (PCNL). Between January 2014 and June 2016, 27 consecutive patients with complex calculi underwent fURS and holmium laser lithotripsy after a planned single-tract PCNL. Among the 27 patients with complex calculi, 9 had full staghorn calculi, 7 had partial staghorn calculi, and 11 had multiple calculi. After the first single-tract PCNL session, the mean stone size and mean stone surface area were 18.0 ± 10.7 mm and 181.9 ± 172.2 mm 2 , respectively. Treatment for residual stones with fURS and holmium laser lithotripsy was successfully completed and was performed without intraoperative complications. The mean operative time of the fURS procedure was 69.1 ± 23.6 min, and the mean hospital stay was 5.3 ± 2.4 days. The mean decrease in the hemoglobin level was 7.3 ± 6.5 g/l. After the fURS procedure, the overall stone-free rate was 88.9%. The overall postoperative complication rate was 14.8% (Clavien grade I 11.1%; Clavien grade II 3.7%). The current approach tested here combines the advantages of both PCNL and fURS and effectively manages complex calculi with a high stone-free rate (SFR) (88.9%). This approach also reduced the number of treatment sessions, the number of percutaneous access tracts, and the blood loss and potential morbidity associated with multiple tracts.

  3. Thulium vapoenucleation of the prostate versus holmium laser enucleation of the prostate for the treatment of large volume prostates: preliminary 6-month safety and efficacy results of a prospective randomized trial.

    PubMed

    Becker, B; Herrmann, T R W; Gross, A J; Netsch, C

    2018-05-05

    We compared the perioperative and postoperative characteristics of thulium vapoenucleation and holmium laser enucleation of the prostate for the treatment of large volume benign prostatic hyperplasia. A total of 94 patients with benign prostatic hyperplasia and a median prostate size of 80 (IQR 46.75-100) cc were either randomized to thulium vapoenucleation or holmium laser enucleation of the prostate. Patients were assessed preoperatively, 1 and 6 months postoperatively. The median operative time was 60 (IQR 41-79) min without significant differences between the groups. There were no significant differences between the groups regarding catheter time [2 (IQR 2-2) days] and postoperative stay [2 (IQR 2-3) days]. Clavien 1 (13.8%), 2 (3.2%), 3a (2.1%), and Clavien 3b (4.3%) complications occurred without significant differences between the groups. At 6-month follow-up, median maximum flow rate (10.7 vs. 25.9 ml/s), post-void residual urine (100 vs. 6.5 ml), I-PSS (20 vs. 5), quality of life (4 vs. 1), PSA (4.14 vs. 0.71 µg/l), and prostate volume (80 vs. 16 ml) had improved significantly (p < 0.001) compared to baseline without significant differences between the groups. Median PSA decrease was 79.7% (58.8-90.6%) and prostate volume reduction was 74.5% (68.57-87.63%) without differences between the groups. The reoperation rate was zero at 6-month follow-up. Thulium vapoenucleation and holmium laser enucleation of the prostate are safe and effective procedures for the treatment of large volume benign prostatic hyperplasia. Both procedures give satisfactory micturition improvement with low morbidity and sufficient prostate volume reduction at 6-month follow-up.

  4. Transmyocardial laser revascularization in the acute ischaemic heart: no improvement of acute myocardial perfusion or prevention of myocardial infarction.

    PubMed

    Eckstein, F S; Scheule, A M; Vogel, U; Schmid, S T; Miller, S; Jurmann, M J; Ziemer, G

    1999-05-01

    Transmyocardial laser revascularization (TMLR) has been used to provide enhanced myocardial perfusion in patients not suitable for coronary revascularization or angioplasty. This study investigates the acute changes in myocardial perfusion after TMLR with a Holmium:Yttrium-Aluminium-Garnet (YAG) laser with a thermal imaging camera in a model of acute ischaemia, and confirms its midterm effects by post-mortem investigation of magnetic resonance imaging and histopathological examination. Acute myocardial ischaemia was induced by occlusion of the dominant diagonal branch in ten sheep. Perfusion measurements were undertaken first in the unaffected myocardium, then after temporary occlusion of the coronary to obtain a control measurement for ischaemic myocardium. Myocardial perfusion was then evaluated during reperfusion after release of coronary occlusion. Then the coronary was permanently occluded and 20.5+/-2 channels were drilled with the Holmium:YAG laser and perfusion was measured again. The other four sheep served as control with untreated ischaemia. All animals were sacrificed after 28 days following administration of gadolinium i.v. to serve as contrast medium for magnetic resonance tomography. The hearts were subjected to magnetic resonance tomography and histopathological examination. Intraoperative perfusion measurements revealed a decreased perfusion after temporary occlusion and an increased perfusion in reperfused myocardium. After TMLR, no improvement of myocardial perfusion above the ischaemic level could be shown. Magnetic resonance images could neither confirm patent laser channels nor viable myocardium within ischaemic areas. On histology no patent endocardial laser channel could be detected. The transmural features were myocardial infarct with scar tissue. In the presented sheep model with acute ischaemia, TMLR with a Holmium:YAG laser did not provide acute improvement of myocardial perfusion as assessed by a thermal imaging camera. This would suggest no direct contribution of newly created laser channels to myocardial perfusion. As chronic effects are concerned, no perfused laser channels could be identified by later magnetic resonance imaging or histology.

  5. First collaborative experience with thulium laser ablation of localized upper urinary tract urothelial tumors using retrograde intra-renal surgery.

    PubMed

    Defidio, Lorenzo; De Dominicis, Mauro; Di Gianfrancesco, Luca; Fuchs, Gerhard; Patel, Anup

    2011-09-01

    Thulium laser ablation (TLA) outcomes with blinded performance evaluation after retrograde intra-renal surgical (RIRS) treatment of upper urinary tract transitional cell carcinomas (UUT-TCC). A UUT-TCC patient cohort undergoing RIRS-TLA by an international endoscopic surgical collaboration in a European center (April 2005-July 2009), underwent outcomes evaluation. All 4 surgeons were blinded and independently scored both TLA and Holmium:YAG laser ablation performance aspects annually using a Likert scoring system (0-10). All patients (n = 59, median age 66 years, 9 with solitary kidney) had complete UUT inspection. Presenting lesion(s) were intra-renal (n = 30, 51%), ureteral (n = 13, 22%), and combined (n = 16, 27%). Single-stage TLA sufficed in 81.4% (tumors < 1.5 cm). Significant recurrence free survival differences occurred according to primary tumor size >/< 1.5 cm and multi-focality, but location made no difference. Median Likert scores were i) fiber-tip stability --5.5/8.75, p = 0.016; ii) reduced bleeding--5/8.5, p = 0.004; iii)fiber-tip precision--5.5/8.5, p = 0.003; iv) mucosal perforation reduction--3.5/7.5, p = 0.001; v) ablation efficiency tumors < 1.5 cm--6/9, p = 0.017; tumors > 1.5 cm--6.75/6.75, p = 1, and vi) overall efficiency--6/7.5, p = 0.09, for Holmium:YAG and TLA, respectively. The Thulium laser delivered non-inferior recurrence free survival to RIRS-UUT-TCC Holmium:YAG laser ablation, but better median parameter performance scores in fiber-tip stability, precision, reduced bleeding and mucosal perforation reduction in expert ratings. Despite improved photothermal coagulation, and endo-visualization for tumors < 1.5 cm, both ablation and overall efficiency remained challenging for larger tumors with both existing laser technologies.

  6. Evaluation of Contemporary Holmium Laser Fibers for Performance Characteristics.

    PubMed

    Lusch, Achim; Heidari, Emon; Okhunov, Zhamshid; Osann, Kathryn; Landman, Jaime

    2016-05-01

    Several holmium:YAG laser fibers for urologic applications are currently commercially available. We compared contemporary holmium laser fibers with different core sizes for performance characteristics, including energy transmission, fiber failure, fiber flexibility, and core diameter. Single-use fibers from Cook, Boston Scientific, and Storz were tested in small (200 and 272/273 μm), medium (365 μm), and large (550 and 940/1000 μm) core sizes. Fibers were tested in straight and deflected configurations. All fibers were evaluated for flexibility, true fiber diameter, energy transmission, and fiber failure. For energy transmission, fibers were tested at a pulse energy of 1 J and a frequency of 10 Hz for 30 seconds. All tests were performed on a 30 W holmium laser. For the small core fibers, Storz, Cook OptiLite, and Smart Sync had the smallest core diameter (p < 0.005). In the large core group, Cook OptiLite and Boston Scientific AccuMax showed the smallest diameter. Among the small core fibers, Storz and Cook Smart Sync showed a significant higher deflection, whereas in the 550 μm group, Boston Scientific AccuMax and Cook Smart Sync were the most flexible fibers. In the large and medium core groups, Boston Scientific AccuMax showed superior energy transmission (p = 0.007 and p = 0.001, respectively), whereas in the small core group, there was no significant difference between the fibers, except for 272/3 μm (Storz was inferior compared with the competitors [p < 0.0005]). For fiber failure, Storz, Cook OptiLite, and BS AccuTrac completed all testing without failing (200 μm, bending radius <0.5 cm). In the 365 μm group, Cook OptiLite showed superior results, whereas in the large core group, Boston Scientific AccuMax was superior. Performance characteristics differ significantly between different laser fiber diameters and manufacturers, and fiber choice should depend on specific surgical requirements. There is a trend for less fiber fracture at long pulse, high energy, and low frequency, but this finding will require further investigation.

  7. VizieR Online Data Catalog: Spectra of a Holmium in the near-UV. I. Ho I. (Al-Labady+, 2017)

    NASA Astrophysics Data System (ADS)

    Al-Labady, N.; Ozdalgic, B.; Er, A.; Guzelcimen, F.; Ozturk, I. K.; Kroger, S.; Kruzins, A.; Tamanis, M.; Ferber, R.; Basar, G.

    2017-04-01

    The high-resolution spectra of Holmium (Ho) were recorded with a Fourier Transform spectrometer IFS125 HR at the Laser Centre of the University of Latvia in Riga. Two Ho spectra were recorded, one with argon (Ar) as a buffer gas and one with neon (Ne). The spectra cover the ultraviolet spectral range from 25000 up to 31530cm-1, or 317 to 400nm, respectively. (1 data file).

  8. Application of 2-um wavelength holmium lasers for treatment of skin diseases

    NASA Astrophysics Data System (ADS)

    Shcherbakov, Ivan A.; Klimov, Igor V.; Tsvetkov, Vladimir B.; Nerobeev, Alexander I.; Sadovnikova, Lija B.; Eliseenko, Vladimir I.

    1994-09-01

    Theoretical and experimental analysis of the efficiency of application of 2 micrometers pulsed holmium laser for cosmetic and plastic surgery and dermatology is carried out. Preliminary experiments were carried out on rats. Solid state 2 micrometers pulsed laser was allowed to operate in free running mode with pulse energy up to 1.5 J and pulse repetition rate up to 5 Hz. To deliver emission to the object a flexible quartz fiber without further focusing of 2.5 m in length and 400 micrometers of the core diameter was used. The effect of the different power density emission on the skin was studied. The second stage was the study of the influence of 2 micrometers emission on human skin. The results of the removal of hemangioma, papilloma, telangiectasia, nevus, nevus acantholytic, xanthelasma palpebral, verruca, chloasma, pigmental spots, tattoos, etc. are presented. Precision, simplicity, efficiency, and the high cosmetic effect of these operations is noted.

  9. Actively Q-switched, thulium-holmium-codoped fiber laser incorporating a silicon-based, variable-optical-attenuator-based Q switch.

    PubMed

    Jung, Minwan; Han Lee, Ju

    2013-04-20

    An actively Q-switched thulium-holmium-codoped fiber laser incorporating an Si-based variable optical attenuator (VOA) is experimentally demonstrated. It has been shown that an Si-based VOA with a response time of hundreds of nanoseconds can be used as a cost-effective 2 μm Q switch due to its extremely wide operating bandwidth from 1.5 to 2 μm, and low electrical power consumption. In our study, the laser's slope efficiency was measured to be ~17% at an operating wavelength of 1.89 μm. The repetition rate tuning range was from 20 to 80 kHz, which was limited by the optical damage threshold and the response time. The minimum temporal pulsewidth was measured to be ~184 ns at a modulation frequency of 20 kHz, and the corresponding maximum peak power was ~10 W.

  10. Pediatric ureteroscopic stone management.

    PubMed

    Thomas, John C; DeMarco, Romano T; Donohoe, Jeffrey M; Adams, Mark C; Brock, John W; Pope, John C

    2005-09-01

    We reviewed our experience of 5 years using ureteroscopy with laser lithotripsy to treat stone disease in prepubertal children. A retrospective review was performed of all ureteroscopic procedures performed in prepubertal children. A total of 33 ureteroscopic procedures were performed in 29 prepubertal children (15 males and 14 females) 5 to 144 months old (mean age 94 months, including 3 patients 24 months or younger). Stones were located in the renal pelvis in 1 case (3%), proximal ureter in 3 (9%), mid ureter in 5 (15%) and distal ureter in 24 (73%). Stone size ranged from 3 to 14 mm (mean 6). Eight patients required balloon dilation of the ureteral orifice. Followup ranged from 1 to 66 months (mean 11). Stone-free rate after initial ureteroscopy and laser lithotripsy was 88%, with all distal and mid ureteral stones (3 to 9 mm, mean 5) successfully treated. Three patients with proximal ureteral stones 7 to 14 mm in diameter (mean 10.3) required a secondary procedure (repeat ureteroscopy in 2 and shock wave lithotripsy in 1) to become stone-free. One patient with cystinuria and a renal pelvic stone measuring 14 mm required shock wave lithotripsy and percutaneous nephrostolithotomy. There were no major complications of ureteroscopy but there was 1 case of extravasation at the ureterovesical junction after balloon dilation that was managed with stent placement. Although more patients and longer followup are needed, ureteroscopy with laser lithotripsy is an excellent first line treatment for children with stones in whom conservative therapy fails, especially those with distal and mid ureteral stones. Patients with a stone burden of 10 mm or greater, especially in the proximal ureter, likely will require a secondary procedure to become stone-free.

  11. Treatment of ureteral calculus obstruction with laser lithotripsy in an Atlantic bottlenose dolphin (Tursiops truncatus).

    PubMed

    Schmitt, Todd L; Sur, Roger L

    2012-03-01

    An adult female bottlenose dolphin (Tursiops truncatus) presented with acute anorexia secondary to progressive azotemia (blood urea nitrogen = 213 mg/dl, creatinine [Cr] = 9.5 mg/dl) and electrolyte abnormalities (K = 7.4 mEq/L). It was later diagnosed with postrenal obstruction secondary to bilaterally obstructing ureteral calculi seen on ultrasound. Treatment of the obstruction required two endoscopic procedures, cystoscopy for ureteral stent placement and ureteroscopy to perform intracorporeal lithotripsy on the obstructing calculi. Before the first procedure, the dolphin's azotemia was stabilized with aggressive fluid therapy, peritoneal dialysis, and treatment for acidosis. Diuresis subsequent to the fluid therapy enabled passage of the right obstructing urolith. For both endoscopic procedures, the dolphin was placed in left lateral recumbency due to the peritoneal dialysis catheter in the right retroperitoneal region. For the first procedure, a 12-French (Fr) flexible cystoscope was inserted retrograde into the bladder via the urethra, whereupon a calculus was seen obstructing the left ureteral orifice. A 4.8-Fr, 26-cm double-pigtail ureteral stent was placed up the left ureter to relieve the postrenal obstruction. Inadvertent proximal migration of the left ureteral stent occurred during the procedure. However, renal parameters (serum Cr = 5.8, K = 5.4) improved significantly by the next day. For the second procedure, 28 hr later, ureteroscopy was performed to treat the calculus and replace the existing stent with a longer stent. The left ureteral calculus was pulverized into tiny fragments by using a holmium:yttrium-aluminum-garnet laser inserted through a 6.9-Fr semirigid ureteroscope. The migrated stent was visualized in the distal left ureter and replaced with a 90-cm single-pigtail ureteral stent that was sutured exterior to the urogenital slit and removed 3 days later. Renal function normalized over the next several days, and the dolphin recovered over the next 2 mo.

  12. Rare Earth Laser Engineering Program. Part II.

    DTIC Science & Technology

    YTTRIUM ALUMINUM GARNET , NEAR INFRARED RADIATION, CONCENTRATION(CHEMISTRY), YTTRIUM COMPOUNDS, ALUMINUM COMPOUNDS, OXIDES, RELAXATION, RATES...VANADATES, DOPING, LANTHANUM, ERBIUM, HOLMIUM, GADOLINIUM COMPOUNDS, GARNET , TRANSPORT PROPERTIES, OSCILLATORS, LANTHANUM COMPOUNDS, FLUORIDES.

  13. Complications associated with cervical endoscopic discectomy with the holmium laser.

    PubMed

    Haufe, Scott M W; Mork, Anthony R

    2004-02-01

    Our aim was to determine the rate of surgical complications associated with cervical endoscopic discectomy (CED). There are no studies that state the degree of complications after CED. Forty-one patients underwent CED with holmium laser. Two out of 41 patients incurred vascular compromise during the procedure. One patient developed recurrent laryngeal nerve damage. One patient developed discitis, and two patients complained of a "clicking" sensation postoperatively. Although CED has a relatively high success rate, there is a 15% rate of complications associated with the procedure. Most of the complications were minor (such as vascular compromise, recurrent laryngeal nerve injury, and postoperative "clicking" sensations), but there was one case of severe discitis, and there is the potential of serious complication from both vascular compromise and neural injury.

  14. Characterization of a Ho:Tm:Cr:YAG laser with a Cr:GSAG laser as pumping source

    NASA Technical Reports Server (NTRS)

    Henderson, George W.

    1989-01-01

    Rare earth lasers were in existance since the first laser was developed. The primary lasing elements for the class of lasers in the infrared was neodymium and chromium. However, the need for eye safe lasers in the mid-infrared range has prompted an enormous amount of research to the use of other elements. Holmium was investigated extensively as the source of infrared radiation for atmospheric research as well as medical research. The results and procedure are briefly discussed.

  15. Threshold Damage of In vivo Porcine Skin at 2000 nm Laser Irradiation

    DTIC Science & Technology

    2006-01-01

    surgery. J Clin Laser Med Surg 1992; 10:211-216. 8. Shapshay SM, Rebeiz EE, Pankratov MM. Holmium: Yttrium Aluminium Garnet laser-assisted endoscopic...laser-assisted endoscopic sinus surgery: laboratory experience. Laryngoscope 1991 ; 101:142-149. 10. Min K, Leu H, Zweifel K. Quantitative determination...JTF. Choice of clip levels for beam width measurements using knife-edge techniques. IEEE J. Quantum Electron. 1991 ; 27:1098-1104 19. Finney DJ

  16. Effect of pulse duration on photomechanical response of soft tissue during Ho:YAG laser ablation

    NASA Astrophysics Data System (ADS)

    Jansen, E. Duco; Motamedi, Massoud; Pfefer, T. Joshua; Asshauer, Thomas; Frenz, Martin; Delacretaz, Guy P.; Abela, George S.; Welch, Ashley J.

    1995-05-01

    Mechanical injury during pulsed holmium laser ablation of tissue is caused by rapid bubble expansion and collapse or by laser-induced pressure waves. In this study the effect of pulse duration on the photomechanical response of soft tissue during holmium:YAG laser ablation has been investigated. The dynamics of laser-induced bubble formation was documented in water and in transparent polyacrylamide tissue phantoms with a water concentration of 84%. Holmium:YAG laser radiation ((lambda) equals 2.12 micrometers ) was delivered in water or tissue phantoms via an optical fiber (200 or 400 micrometers ). The laser was operated in either the Q- switched mode ((tau) p equals 500 ns, Qp equals 14 +/- 1 mJ, 200 micrometers fiber, Ho equals 446 mJ/mm2) or the free-running mode ((tau) p equals 100 - 1100 microsecond(s) , Qp equals 200 +/- 5 mJ, 400 micrometers fiber, Ho equals 1592 mJ/mm2). Bubble formation was documented using a fast flash photography setup while simultaneously a PVDP needle hydrophone (40 ns risetime), recorded pressures. The effect of the pulse duration on the photomechanical response of soft biological tissue was evaluated by delivering 5 pulses of 800 mJ to the intimal side of porcine aorta in vitro, followed by histologic evaluation. It was observed that, as the pulse duration was increased the bubble shape changed from almost spherical for Q-switched pulses to a more elongated, cylindrical shape for the longer pulse durations. The bubble expansion velocity was larger for shorter pulse durations. A thermo- elastic expansion wave was measured only during Q-switched pulse delivery. All pulses that induced bubble formation generated pressure waves upon collapse of the bubble in water as well as in the gel. The amplitude of the pressure wave depended strongly on the size and geometry of the laser-induced bubble. The important findings of this study were (1) the magnitude of collapse pressure wave decreased as laser pulse duration increased, and (2) mechanical tissue damage is reduced significantly by using longer pulse durations (> 460 microsecond(s) , for the pulse energy used).

  17. Modular flexible ureteroscopy and holmium laser lithotripsy for the treatment of renal and proximal ureteral calculi: A single-surgeon experience of 382 cases.

    PubMed

    Yan, Zejun; Xie, Guohai; Yuan, Hesheng; Cheng, Yue

    2015-10-01

    To determine the safety and efficacy of modular flexible ureteroscopy and holmium laser lithotripsy for the treatment of renal and proximal ureteral calculi, a retrospective chart review of a single surgeon's 3-year modular flexible ureteroscopy experience was performed. All of the patients were treated with modular flexible ureteroscopy and holmium laser lithotripsy by a single surgeon. Stone-free status was defined as no fragments or a single fragment ≤4 mm in diameter at the 3-month follow-up. The procedure number, operative time, stone-free rates, repeat usage of the multilumen catheter, and perioperative complications were documented. The present study included 215 male patients and 167 female patients, with an average age of 48.5±13.7 years (range, 17-84 years). The mean stone size was 11.5±4.1 mm (range, 4-28 mm), and the mean total stone burden was 17.5±5.7 mm (range 15-46 mm). A total of 305 patients (79.8%) had a stone burden ≤20 mm, and 77 patients (20.2%) had a stone burden >20 mm. The mean number of primary procedures was 1.3±0.2 (range, 1-3). The stone-free rate following the first and the second procedure was 73.4 and 86.9%, respectively. The mean postoperative hospital stay was 3.1±1.2 days (range, 2-6 days). The highest clearance rates were observed for proximal ureteral stones (100%) and renal pelvic stones (88.7%), whereas the lowest clearance rates were observed for lower calyx stones (76.7%) and multiple calyx stones (77.8%). The higher the initial stone burden, the lower the postoperative stone-free rate (≤20 vs. >20 mm; 89.8 vs. 75.3%). The overall complication rate was 8.1%. The results of the present study suggest that modular flexible ureteroscopy with holmium laser lithotripsy may be considered the primary method for the treatment of renal and proximal ureteral calculi in select patients, due to its acceptable efficacy, low morbidity, and relatively low maintenance costs.

  18. Carbon Footprint in Flexible Ureteroscopy: A Comparative Study on the Environmental Impact of Reusable and Single-Use Ureteroscopes.

    PubMed

    Davis, Niall F; McGrath, Shannon; Quinlan, Mark; Jack, Gregory; Lawrentschuk, Nathan; Bolton, Damien M

    2018-03-01

    There are no comparative assessments on the environmental impact of endourologic instruments. We evaluated and compared the environmental impact of single-use flexible ureteroscopes with reusable flexible ureteroscopes. An analysis of the typical life cycle of the LithoVue™ (Boston Scientific) single-use digital flexible ureteroscope and Olympus Flexible Video Ureteroscope (URV-F) was performed. To measure the carbon footprint, data were obtained on manufacturing of single-use and reusable flexible ureteroscopes and from typical uses obtained with a reusable scope, including repairs, replacement instruments, and ultimate disposal of both ureteroscopes. The solid waste generated (kg) and energy consumed (kWh) during each case were quantified and converted into their equivalent mass of carbon dioxide (kg of CO 2 ) released. Flexible ureteroscopic raw materials composed of plastic (90%), steel (4%), electronics (4%), and rubber (2%). The manufacturing cost of a flexible ureteroscope was 11.49 kg of CO 2 per 1 kg of ureteroscope. The weight of the single-use LithoVue and URV-F flexible ureteroscope was 0.3 and 1 kg, respectively. The total carbon footprint of the lifecycle assessment of the LithoVue was 4.43 kg of CO 2 per endourologic case. The total carbon footprint of the lifecycle of the reusable ureteroscope was 4.47 kg of CO 2 per case. The environmental impacts of the reusable flexible ureteroscope and the single-use flexible ureteroscope are comparable. Urologists should be aware that the typical life cycle of urologic instruments is a concerning source of environmental emissions.

  19. Comparison of three pulsed infrared lasers for optical stimulation of the rat prostate cavernous nerves

    NASA Astrophysics Data System (ADS)

    Stahl, Charlotte S. D.; Tozburun, Serhat; Hutchens, Thomas C.; Lagoda, Gwen A.; Burnett, Arthur L.; Keller, Matthew D.; Fried, Nathaniel M.

    2013-03-01

    Optical nerve stimulation (ONS) is being explored for identification and preservation of the cavernous nerves (CN), responsible for erectile function, during prostate cancer surgery. This study compares three pulsed infrared lasers to determine whether differences in spectral linewidth and/or temporal pulse profile influence successful ONS of CN. Infrared laser radiation from the Capella diode laser (1873 nm, 5 ms, 10 Hz), Thulium fiber laser (TFL) (1873 nm, 5 ms, 10 Hz), and solid-state Holmium:YAG laser (2120 nm, 200 μs, 5 Hz) were transmitted through 400-μm-corediameter optical fibers, producing a 1-mm-diameter-spot on the nerve surface. Successful ONS was judged by an intracavernous pressure (ICP) response in the penis (n =10 rats) during a total stimulation time of 30 s. The narrow linewidth TFL (Δλ 0.5 nm) and broad linewidth Capella laser (Δλ 12 nm) performed similarly, producing ICP responses with a threshold radiant exposure of 0.45 J/cm2, and ICP response times of 12-17 s, while the Holmium laser stimulated at 0.59 J/cm2, and ICP response times of about 14-28 s. All three lasers demonstrated successful ONS of CN. ICP response time was dependent on the rate of energy deposition into the CN, rather than linewidth or temporal pulse profile.

  20. Recent development on high-power tandem-pumped fiber laser

    NASA Astrophysics Data System (ADS)

    Zhou, Pu; Xiao, Hu; Leng, Jinyong; Zhang, Hanwei; Xu, Jiangmin; Wu, Jian

    2016-11-01

    High power fiber laser is attracting more and more attention due to its advantage in excellent beam quality, high electricto- optical conversion efficiency and compact system configuration. Power scaling of fiber laser is challenged by the brightness of pump source, nonlinear effect, modal instability and so on. Pumping active fiber by using high-brightness fiber laser instead of common laser diode may be the solution for the brightness limitation. In this paper, we will present the recent development of various kinds of high power fiber laser based on tandem pumping scheme. According to the absorption property of Ytterbium-doped fiber, Thulium-doped fiber and Holmium-doped fiber, we have theoretically studied the fiber lasers that operate at 1018 nm, 1178 nm and 1150 nm, respectively in detail. Consequently, according to the numerical results we have optimized the fiber laser system design, and we have achieved (1) 500 watt level 1018nm Ytterbium-doped fiber laser (2) 100 watt level 1150 nm fiber laser and 100 watt level random fiber laser (3) 30 watt 1178 nm Ytterbium-doped fiber laser, 200 watt-level random fiber laser. All of the above-mentioned are the record power for the corresponded type of fiber laser to the best of our knowledge. By using the high-brightness fiber laser operate at 1018 nm, 1178 nm and 1150 nm that we have developed, we have achieved the following high power fiber laser (1) 3.5 kW 1090 nm Ytterbium-doped fiber amplifier (2) 100 watt level Thulium-doped fiber laser and (3) 50 watt level Holmium -doped fiber laser.

  1. Holmium:YAG laser coronary angioplasty in patients with lesions not ideal for balloon angioplasty

    NASA Astrophysics Data System (ADS)

    Miyazaki, Shunichi; Nonogi, Hiroshi; Goto, Yoichi; Itoh, Akira; Ozono, Keizaburo; Daikoku, Satoshi; Haze, Kazuo

    1993-06-01

    Conventional balloon coronary angioplasty has limitations for application on particular lesions, such as lesions near the left main trunk (LMT), ostial location, and highly eccentric lesions. Hence, efficacy of newly developed Holmium YAG laser coronary angioplasty (HLCA) was assessed for 24 patients with angina. Adjunctive balloon angioplasty was performed for 21 of 24 lesions. Delivered energy ranged from 1.5 to 2.5 watts/pulse and the total exposure time ranged from 6 to 32 seconds. Laser success, defined as 20% reduction of stenotic ratio, was obtained in 16 of 24 (67%) and overall procedural success rate was 92%. Follow up coronary angiography after 3 months showed restenosis in 9 of 19 patients (47%). HLCA is an acutely effective treatment for lesions identified as not ideal for balloon angioplasty. However, angiographical restenosis rate is similar to the conventional balloon angioplasty and a highly calcified complex lesion may not be a candidate for the treatment of HLCA, because of a potential risk of coronary perforation.

  2. All-fiber thulium/holmium-doped mode-locked laser by tungsten disulfide saturable absorber

    NASA Astrophysics Data System (ADS)

    Yu, Hao; Zheng, Xin; Yin, Ke; Cheng, Xiang'ai; Jiang, Tian

    2017-01-01

    A passively mode-locked thulium/holmium-doped fiber laser (THDFL) based on tungsten disulfide (WS2) saturable absorber (SA) was demonstrated. The WS2 nanosheets were prepared by liquid phase exfoliation method and the SA was fabricated by depositing the few-layer WS2 nanosheets on the surface of a fiber taper. The modulation depth, saturable intensity, and non-saturable loss of this SA were measured to be 8.2%, 0.82 GW cm-2, and 29.4%, respectively. Based on this SA, a stable mode-locked laser operated at 1.91 µm was achieved with pulse duration of 825 fs and repetition rate of 15.49 MHz, and signal-to-noise ratio (SNR) of 67 dB. Meanwhile, by increasing the pump power and adjusting the position of polarization controller, harmonic mode-locking operations were obtained. These results showed that the WS2 nanosheet-based SA could be served as a desirable candidate for a short-pulse mode locker at 2 µm wavelength.

  3. Next-Generation Single-Use Ureteroscopes: An In Vitro Comparison.

    PubMed

    Tom, Westin R; Wollin, Daniel A; Jiang, Ruiyang; Radvak, Daniela; Simmons, Walter Neal; Preminger, Glenn M; Lipkin, Michael E

    2017-12-01

    Single-use ureteroscopes have been gaining popularity in recent years. We compare the optics, deflection, and irrigation flow of two novel single-use flexible ureteroscopes-the YC-FR-A and the NeoFlex-with contemporary reusable and single-use flexible ureteroscopes. Five flexible ureteroscopes, YC-FR-A (YouCare Tech, China), NeoFlex (Neoscope, Inc., USA), LithoVue (Boston Scientific, USA), Flex-Xc (Karl Storz, Germany), and Cobra (Richard Wolf, Germany), were assessed in vitro for image resolution, distortion, field of view, depth of field, color representation, and grayscale imaging. Ureteroscope deflection and irrigation were also compared. The YC-FR-A showed a resolution of 5.04 lines/mm and 4.3% image distortion. NeoFlex showed a resolution of 17.9 lines/mm and 14.0% image distortion. No substantial difference was demonstrated regarding the other optic characteristics between the two. Across all tested ureteroscopes, single-use or reusable, the digital scopes performed best with regard to optics. The YC-FR-A had the greatest deflection at baseline, but lacks two-way deflection. The NeoFlex had comparable deflection at baseline to reusable devices. Both ureteroscopes had substantial loss of deflection with instruments in the working channel. The YC-FR-A had the greatest irrigation rate. The NeoFlex has comparable irrigation to contemporary ureteroscopes. The YouCare single-use fiberoptic flexible ureteroscope and NeoFlex single-use digital flexible ureteroscope perform comparably to current reusable ureteroscopes, possibly making each a viable alternative in the future. Newer YouCare single-use flexible ureteroscopes with a digital platform and two-way deflection may be more competitive, while the NeoFlex devices are undergoing rapid improvement as well. Further testing is necessary to validate the clinical performance and utility of these ureteroscopes, given the wide variety of single-use devices under development.

  4. Defining the Costs of Reusable Flexible Ureteroscope Reprocessing Using Time-Driven Activity-Based Costing.

    PubMed

    Isaacson, Dylan; Ahmad, Tessnim; Metzler, Ian; Tzou, David T; Taguchi, Kazumi; Usawachintachit, Manint; Zetumer, Samuel; Sherer, Benjamin; Stoller, Marshall; Chi, Thomas

    2017-10-01

    Careful decontamination and sterilization of reusable flexible ureteroscopes used in ureterorenoscopy cases prevent the spread of infectious pathogens to patients and technicians. However, inefficient reprocessing and unavailability of ureteroscopes sent out for repair can contribute to expensive operating room (OR) delays. Time-driven activity-based costing (TDABC) was applied to describe the time and costs involved in reprocessing. Direct observation and timing were performed for all steps in reprocessing of reusable flexible ureteroscopes following operative procedures. Estimated times needed for each step by which damaged ureteroscopes identified during reprocessing are sent for repair were characterized through interviews with purchasing analyst staff. Process maps were created for reprocessing and repair detailing individual step times and their variances. Cost data for labor and disposables used were applied to calculate per minute and average step costs. Ten ureteroscopes were followed through reprocessing. Process mapping for ureteroscope reprocessing averaged 229.0 ± 74.4 minutes, whereas sending a ureteroscope for repair required an estimated 143 minutes per repair. Most steps demonstrated low variance between timed observations. Ureteroscope drying was the longest and highest variance step at 126.5 ± 55.7 minutes and was highly dependent on manual air flushing through the ureteroscope working channel and ureteroscope positioning in the drying cabinet. Total costs for reprocessing totaled $96.13 per episode, including the cost of labor and disposable items. Utilizing TDABC delineates the full spectrum of costs associated with ureteroscope reprocessing and identifies areas for process improvement to drive value-based care. At our institution, ureteroscope drying was one clearly identified target area. Implementing training in ureteroscope drying technique could save up to 2 hours per reprocessing event, potentially preventing expensive OR delays.

  5. Spectra- and temperature-dependent dynamics of directly end-pumped holmium lasers

    NASA Astrophysics Data System (ADS)

    Ji, Encai; Shen, Yijie; Nie, Mingming; Fu, Xing; Liu, Qiang

    2017-04-01

    We develop a theoretical model with high accuracy for directly end-pumped Ho3+ laser system considering the influences of ground-state depletion, energy transfer up-conversion, temperature-dependent cross sections, and pump spectra shift. The heat generation in our model is precisely evaluated by calculating the transition rates of non-radiation relaxation processes among manifolds and in-band relaxation processes based on a detailed analysis of energy levels structure of holmium ions. A spatial dynamic thermal iteration method, just developed by our group, is applied to describe the coupled influences between spatial thermal effects and pump spectra. This model is verified to both adapt to the narrow-band good beam-quality pumped case and the broad-band bad beam-quality pumped case, which is in accordance with our previous reported experimental results.

  6. Critical review of lasers in benign prostatic hyperplasia (BPH).

    PubMed

    Gravas, Stavros; Bachmann, Alexander; Reich, Oliver; Roehrborn, Claus G; Gilling, Peter J; De La Rosette, Jean

    2011-04-01

    • Laser treatment of benign prostatic hyperplasia has challenged transurethral resection of the prostate (TURP) due to advances in laser technology, better understanding of tissue-laser interactions and growing clinical experience. • Various lasers have been introduced including neodymium: yttrium aluminium garnet (YAG), holmium (Ho):YAG, potassium titanyl phosphate:YAG, thulium(Tm) and diode laser. Based on the different wave-length dependent laser-prostatic tissue interactions, the main techniques are coagulation, vaporization, resection and enucleation. • The present review aims to help urologists to distinguish and to critically evaluate the role of different laser methods in the treatment by using an evidence-based approach. It also details further evidence for use in specific patient groups (in retention, on anticoagulation) and addresses the issues of cost and learning curve. • Coagulation-based techniques have been abandoned; holmium ablation/resection of the prostate has been superseded by the enucleation technique Ho-laser enucleation of the prostate (HoLEP). The short-term efficacy of the emerging laser treatments such as diode and Tm prostatectomy has been suggested by low quality studies. HoLEP and photoselective vaporization of the prostate (PVP) represent valid clinical alternatives to TURP. HoLEP is the most rigorously analysed laser technique with durable efficacy for any prostate size and low early and late morbidity. PVP has grown in acceptance and popularity but long-term results from high quality studies are pending. © 2010 THE AUTHORS; BJU INTERNATIONAL © 2010 BJU INTERNATIONAL.

  7. Use of the holmium:YAG laser in urology.

    PubMed

    Johnson, D E; Cromeens, D M; Price, R E

    1992-01-01

    The tissue effects of a holmium:YAG (Ho:YAG) laser operating at a wavelength of 2.1 mu with a maximum power of 15 watts (W) and 10 different energy-pulse settings was systematically evaluated on kidney, bladder, prostate, ureteral, and vasal tissue in the dog. In addition, various urologic surgical procedures (partial nephrectomy, transurethral laser incision of the prostate, and laser-assisted vasovasostomy) were performed in the dog, and a laparoscopic pelvic lymph node dissection was carried out in a pig. Although the Ho:YAG laser has a strong affinity for water, precise tissue ablation was achieved in both the contact and non-contact mode when used endoscopically in a fluid medium to ablate prostatic and vesical tissue. Using the usual parameters for tissue destruction (blanching without charring), the depth of thermal injury in the bladder and ureter was kept superficial. In performing partial nephrectomies, a 2-fold reduction in the zone of coagulative necrosis was demonstrated compared to the use of the continuous wave Neodymium:YAG laser (Nd:YAG). When used through the laparoscope, the Ho:YAG laser provided precise cutting and, combined with electrocautery, allowed the dissection to proceed quickly and smoothly. Hemostatic control was adequate in all surgical procedures. Although the results of these investigations are preliminary, our initial experience with the Ho:YAG laser has been favorable and warrants further investigations.

  8. Operation of Ho:YAG ultrafast laser inscribed waveguide lasers.

    PubMed

    McDaniel, Sean; Thorburn, Fiona; Lancaster, Adam; Stites, Ronald; Cook, Gary; Kar, Ajoy

    2017-04-20

    We report fabrication and operation of multi-watt level waveguide lasers utilizing holmium-doped yttrium aluminum garnet (Ho:YAG). The waveguides were fabricated using ultrafast laser inscription, which relies on a chirped pulse ytterbium fiber laser to create depressed cladding structures inside the material. A variety of waveguides were created inside the Ho:YAG samples. We demonstrate output powers of ∼2  W from both a single-mode 50 μm waveguide laser and a multimode 80 μm waveguide laser. In addition, laser action from a co-doped Yb:Ho:YAG sample under in-band pumping conditions was demonstrated.

  9. Holmium: YAG laser lithotripsy versus pneumatic lithotripsy for treatment of distal ureteral calculi: a meta-analysis.

    PubMed

    Yin, Xiangrui; Tang, Ziwei; Yu, Bei; Wang, Yarong; Li, Yuehua; Yang, Qi; Tang, Wei

    2013-04-01

    The objective of this study was to estimate the treatment effect of Pneumatic Lithotripsy (PL) versus holmium: YAG laser lithotripsy (LL) in the treatment of distal ureteric calculi. A bibliographic search covering the period from 1990 to April 2012 was conducted using search engines such as MEDLINE, EMBASE, and Cochrane library. Data were extracted and analyzed with RevMan5.1 software. A total of 47 studies were scant, and 4 independent studies were finally recruited. Holmium: YAG LL conveyed significant benefits compared with PL in terms of early stone-free rate [odds ratio (OR)=4.42, 95% confidence interval (CI) (1.14, 17.16), p=0.03], delayed stone-free rate [OR=4.42, 95%CI (1.58, 12.37), p=0.005], mean operative time [WMD=-16.86, 95%CI (-21.33, -12.39), p<0.00001], retaining double-J catheter rate [OR=0.44, 95%CI (0.25, 0.78), p=0.004], and stone migration incidence [OR=0.26, 95%CI (0.11, 0.62), p=0.003], but not yet in the postoperative hematuria rate and the ureteral perforation rate according to this meta-analysis. Precise estimates on larger sample size and trials of high quality may provide more uncovered outcomes in the future.

  10. Flexible ureteroscopic laser lithotripsy for upper urinary tract stone disease in patients with spinal cord injury.

    PubMed

    Tepeler, Abdulkadir; Sninsky, Brian C; Nakada, Stephen Y

    2015-11-01

    The objective of this study is to present the outcomes of flexible ureteroscopic laser lithotripsy (URS) for upper urinary tract stone disease in spinal cord injury (SCI) patients performed by a single surgeon. A retrospective analysis was performed for SCI patients treated with flexible URS for proximal ureter and kidney stone disease by a single surgeon between 2003 and 2013. Patient characteristics, operative outcomes, metabolic evaluation, and stone analyses were assessed in detail. A total of 27 URS procedures were performed for urolithiasis in 21 renal units of 19 patients. The mean age was 52.1 ± 15.6 years (16-72) and mean BMI was 29.2 ± 7.3 kg/m(2) (20-45.7). Etiology of SCI was trauma (n: 10), multiple sclerosis (n: 6), cerebrovascular accident (n: 1), or undetermined (n: 2). The mean stone size was 15.9 ± 8.6 (6-40) mm. In the 27 URS procedures, stones were located in the ureter (n: 5), the kidney (n: 14), and both areas (n: 8). Mean hospitalization time was 2.0 ± 2.4 (0-10) days. Postoperative complications were observed in 6 cases (22.2%). Three major complications included urosepsis (n: 1) and respiratory failure (n: 2), that were observed postoperatively and required admission to the intensive care unit. The 2 minor complications were hypotension, fever and UTI, and required medical treatment. Fourteen (66.6%) of the 21 renal units were stone free. Calcium phosphate carbonate (n: 9) and struvite (n: 5) were the primary stone compositions detected. Hypocitraturia (n: 6), hypercalciuria (n: 5), hypernaturia (n: 5), hyperoxaluria (n: 4), and hyperuricosuria (n: 1) were common abnormalities in 24-h urine analysis. Ureteroscopic laser lithotripsy can be an effective treatment modality for SCI patients with upper urinary tract calculi.

  11. Clinical development of holmium:YAG laser prostatectomy

    NASA Astrophysics Data System (ADS)

    Kabalin, John N.

    1996-05-01

    Holmium:YAG (Ho:YAG) laser vaporization and resection of the prostate offers advantages in immediate tissue removal compared to the Neodymium:YAG (Nd:YAG) laser. Ongoing development of appropriate operative techniques and Ho:YAG laser delivery systems suitable for endoscopic prostate surgery, including side-firing optical delivery fibers, have facilitated this approach. We performed Ho:YAG laser prostatectomy in 20 human subjects, including 2 men treated immediately prior to radical prostatectomy to assess Ho:YAG laser effects in the prostate. A total of 18 men were treated in an initial clinical trial of Ho:YAG prostatectomy. Estimated excess hyperplastic prostate tissue averaged 24 g (range 5 - 50 g). A mean of 129 kj Ho:YAG laser energy was delivered, combined with a mean of 11 kj Nd:YAG energy to provide supplemental coagulation for hemostasis. We have observed no significant perioperative or late complications. No significant intraoperative changes in hematocrit or serum electrolytes were documented. In addition to providing acute removal of obstructing prostate tissue, Ho:YAG laser resection allowed tissue specimen to be obtained for histologic examination. A total of 16 of 18 patients (90%) underwent successful removal of their urinary catheter and voiding trial within 24 hours following surgery. Immediate improvement in voiding, comparable to classic transurethral electrocautery resection of the prostate (TURP), was reported by all patients. Ho:YAG laser resection of the prostate appears to be a viable surgical technique associated with minimal morbidity and immediate improvement in voiding.

  12. Holmium:YAG surgical lasers.

    PubMed

    1995-03-01

    "Holmium:YAG (Ho:YAG)" is the shorthand name for a family of solid-state lasers that use the doping element holmium in a laser crystal (e.g., YAG [yttrium-aluminum-garnet]) and that emit energy at approximately 2.1 microns. This wavelength is relatively new to medicine and has been used in laser surgery for only about the last six years. Like the carbon dioxide (CO2) laser when it was first used clinically, the Ho:YAG laser is poised for rapid and wide-spread use. Ho:YAG lasers, like CO2 lasers, offer precise cutting with minimal damage to adjacent tissue; however, unlike CO2 lasers, they also offer fiberoptic delivery (which is ideal for endoscopic use) and the ability to treat tissue in a liquid-filled environment (e.g., saline, blood). The initial specialty for which the Ho:YAG laser was used was arthroscopic surgery, especially diskectomy. Today, it is effectively used in many surgical specialties, including general surgery, urology, laparoscopy, neurosurgery, lithotripsy, angioplasty, orthopedic surgery (which includes procedures such as meniscectomy, bone sculpting [may also be performed in plastic surgery], and some experimental surgery, such as cartilage shrinking to tighten loose joints), and dentistry. Because of its broad range of potential applications, it has been called the "Swiss Army Knife" of lasers. High-powered Ho:YAG lasers, which enable surgeons to work more quickly and cut more smoothly, have been made available only within the last three years (units offering > 20 W) to 18 months (units offering > 60 W). Because of this rapid increase, high-powered units are still relatively expensive, and it is not yet clear whether maximum power outputs will continue to increase or whether the cost of higher-power units will begin to come down. Although low-power and high-power Ho:YAG lasers can be used for the same procedures, their different ranges of possible clinical techniques make them better suited to different applications: low-power units are preferable for small-joint and some head-and-neck surgeries or for office use, and high-power units are more suitable for use in major surgery, such as gastrointestinal surgery or surgery in large joints. This evaluation includes two units at both ends of the Ho:YAG power spectrum--one 10 W and one 60 W--and thus provides a guide to evaluating other Ho:YAG lasers that are currently available or that will be entering the market.(ABSTRACT TRUNCATED AT 400 WORDS)

  13. Gain and energy storage in holmium YLF

    NASA Technical Reports Server (NTRS)

    Storm, Mark E.; Deyst, John P.

    1991-01-01

    It is demonstrated that Q-switched holmium lasers are capable of high-gain and high-energy operation at 300 K. Small-signal gain coefficients of 0.50 and 0.12/cm have been measured in YLF and YAG, respectively. Small-signal gains of 0.50/cm are comparable to those achievable in Nd:YAG and are not typical of low-gain materials. This large gain in the Ho:YLF material is made possible by operating the amplifier in the ground state depletion mode. The amplifier performance data and associated analysis presented demonstrate that efficient energy storage is possible with very high excited state ion densities of the Ho 5I7 upper laser level. This is an important result since upconversion can limit the 5I7 population. Although upconversion was still present in this experiment, it was possible to achieve efficient energy storage, demonstrating that the problem is manageable even at high excitation densities in YLF.

  14. Value of focal applied energy quotient in treatment of ureteral lithiasis with shock waves.

    PubMed

    Arrabal-Polo, Miguel Angel; Arrabal-Martin, Miguel; Palao-Yago, Francisco; Mijan-Ortiz, Jose Luis; Zuluaga-Gomez, Armando

    2012-08-01

    The treatment of ureteral lithiasis by extracorporeal shock wave lithotripsy (ESWL) is progressively being abandoned owing to advances in endoscopic lithotripsy. The purpose of this paper is to analyze the causes as to why ESWL is less effective-with a measurable parameter: focal applied energy quotient (FAEQ) that allows us to apply an improvement project in ESWL results for ureteral lithiasis. A prospective observational cohort study with 3-year follow-up and enrollment period was done with three groups of cases. In Group A, 83 cases of ureteral lithiasis were treated by endoscopic lithotripsy using Holmiun:YAG laser. In Group B, 81 cases of ureteral lithiasis were treated by ESWL using Doli-S device (EMSE 220F-XXP). In Group C, 65 cases of ureteral lithiasis were treated by ESWL using Doli-S device (EMSE 220F-XXP) (FAEQ >10). Statistical study and calculation of RR, NNT, Chi-square test, Fisher's exact test, and Student's t test were done. Efficiency quotient (EQ) and focal applied energy quotient [FAEQ = (radioscopy seconds/number of shock waves) × ESWL session J] were analyzed. From the results, the success rate of the treatment using Holmium:YAG laser lithotripsy and ESWL is found to be 94 and 48%, respectively, with a statistically significant difference (p < 0.001). Success rate of endoscopic laser lithotripsy for lumbar ureteral stones was 82% versus 57% of ESWL (p = 0.611). In Group B, FAEQ was 8.12. In Group C, success rate was 93.84% with FAEQ of 10.64%. When we compare results from endoscopic lithotripsy with Holmium:YAG laser in Group B with results from ESWL with FAEQ >10, we do not observe absolute benefit choosing one or the other. In conclusion, the application of ESWL with FAEQ >10, that is, improving radiologic focalization of the calculus and increasing the number of Joules/SW, makes possible a treatment as safe and equally efficient as Holmium:YAG laser lithotripsy in ureteral lithiasis less than 13 mm.

  15. Thulium fiber laser recanalization of occluded ventricular catheters in an ex vivo tissue model

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas C.; Gonzalez, David A.; Hardy, Luke A.; McLanahan, C. Scott; Fried, Nathaniel M.

    2017-04-01

    Hydrocephalus is a chronic medical condition that occurs in individuals who are unable to reabsorb cerebrospinal fluid (CSF) created within the ventricles of the brain. Treatment requires excess CSF to be diverted from the ventricles to another part of the body, where it can be returned to the vascular system via a shunt system beginning with a catheter within the ventricle. Catheter failures due to occlusion by brain tissues commonly occur and require surgical replacement of the catheter. In this preliminary study, minimally invasive clearance of occlusions is explored using an experimental thulium fiber laser (TFL), with comparison to a conventional holmium: yttrium aluminium garnet (YAG) laser. The TFL utilizes smaller optical fibers (<200-μm OD) compared with holmium laser (>450-μm OD), providing critical extra cross-sectional space within the 1.2-mm-inner-diameter ventricular catheter for simultaneous application of an endoscope for image guidance and a saline irrigation tube for visibility and safety. TFL ablation rates using 100-μm core fiber, 33-mJ pulse energy, 500-μs pulse duration, and 20- to 200-Hz pulse rates were compared to holmium laser using a 270-μm core fiber, 325-mJ, 300-μs, and 10 Hz. A tissue occluded catheter model was prepared using coagulated egg white within clear silicone tubing. An optimal TFL pulse rate of 50 Hz was determined, with an ablation rate of 150 μm/s and temperature rise outside the catheter of ˜10°C. High-speed camera images were used to explore the mechanism for removal of occlusions. Image guidance using a miniature, 0.7-mm outer diameter, 10,000 pixel endoscope was explored to improve procedure safety. With further development, simultaneous application of TFL with small fibers, miniature endoscope for image guidance, and irrigation tube for removal of tissue debris may provide a safe, efficient, and minimally invasive method of clearing occluded catheters in the treatment of hydrocephalus.

  16. Bleeding after holmium laser enucleation of the prostate: lessons learned the hard way.

    PubMed

    Martin, Aaron D; Nunez, Rafael N; Humphreys, Mitchell R

    2011-02-01

    To examine specific causes of postoperative bleeding requiring transfusion after holmium laser enucleation of the prostate (HoLEP) in order to enhance preoperative screening and counseling. After Institutional Review Board (IRB) approval, a retrospective review of a single surgeon's experience of 130 consecutive HoLEPs was performed to specifically examine patients requiring perioperative blood transfusions. All patients from August 2007 to April 2009 who underwent a HoLEP at our institution since its inception were included. These patients' charts were reviewed to gain insight into their bleeding diathesis. A case series report was compiled and compared with the relevant published literature. Of the 130 patients, eight (6.7%) were found to require transfusion postoperatively. Four of these patients required a second operation for completion. These patients had a variety of causes for increased bleeding and subsequent transfusion including: chronic anticoagulation (n = 1), significant cardiac disease requiring maintenance of hemoglobin (n = 4), sepsis with secondary disseminated intravascular coagulation (n = 1), large prostate size (>150 g) (n = 4), underlying prostate cancer (n = 1) and inadequate anesthesia during the procedure leading to patient movement (n = 1). All patients made a full recovery with satisfactory urinary symptom improvement except for one patient with residual incontinence at last follow-up. Despite the many benefits of holmium laser enucleation, all patients should be counseled regarding the real potential for postoperative blood transfusion. When feasible, any known bleeding risk should be minimized by the surgeon as long it is done safely for the benefit of the patient considering their co-morbidities. © 2010 THE AUTHORS. JOURNAL COMPILATION © 2010 BJU INTERNATIONAL.

  17. Ablation of intervertebral discs in dogs using a MicroJet-assisted dye-enhanced injection device coupled with the diode laser

    NASA Astrophysics Data System (ADS)

    Bartels, Kenneth E.; Henry, George A.; Dickey, D. Thomas; Stair, Ernest L.; Powell, Ronald; Schafer, Steven A.; Nordquist, Robert E.; Frederickson, Christopher J.; Hayes, Donald J.; Wallace, David B.

    1998-07-01

    Use of holmium laser energy for vaporization/coagulation of the nucleus pulposus in canine intervertebral discs has been previously reported and is currently being applied clinically in veterinary medicine. The procedure was originally developed in the canine model and intended for potential human use. Since the pulsed (15 Hz) holmium laser energy exerts photomechanical and photothermal effects, the potential for extrusion of additional disc material to the detriment of the patient is possible using the procedure developed for the dog. To reduce this potential complication, use of diode laser (805 nm - CW mode) energy, coupled with indocyanine green (ICG) as a selective laser energy absorber, was formulated as a possible alternative. Delivery of the ICG and diode laser energy was through a MicroJet device that could dispense dye interactively between individual laser 'shots.' Results have shown that it is possible to selectively ablate nucleus pulposus in the canine model using the device described. Acute observations (gross and histopathologic) illustrate that accurate placement of the spinal needle before introduction of the MicroJet device is critically dependent on the expertise of the interventional radiologist. In addition, the success of the overall technique depends on consistent delivery of both ICG and diode laser energy. Minimizing tissue carbonization on the tip of the MicroJet device is also of crucial importance for effective application of the technique in clinical veterinary medicine.

  18. Hyperfine structure investigations for the odd-parity configuration system in atomic holmium

    NASA Astrophysics Data System (ADS)

    Stefanska, D.; Furmann, B.

    2018-02-01

    In this work new experimental results of the hyperfine structure (hfs) in the holmium atom are reported, concerning the odd-parity level system. Investigations were performed by the method of laser induced fluorescence in a hollow cathode discharge lamp on 97 spectral lines in the visible part of the spectrum. Hyperfine structure constants: magnetic dipole - A and electric quadrupole - B for 40 levels were determined for the first time; for another 21 levels the hfs constants available in the literature were remeasured. Results for the A constants can be viewed as fully reliable; for B constants further possibilities of improving the accuracy are considered.

  19. Novel application of an established technique for removing a knotted ureteric stent.

    PubMed

    Tempest, Heidi; Turney, Ben; Kumar, Sunil

    2011-04-13

    This report describes a case whereby a ureteric stent became knotted during removal and lodged within the upper ureter. The authors describe a novel minimally invasive technique to remove the knotted ureteric stent using the holmium laser.

  20. Mechanism of laser-induced stress relaxation in cartilage

    NASA Astrophysics Data System (ADS)

    Sobol, Emil N.; Sviridov, Alexander P.; Omelchenko, Alexander I.; Bagratashvili, Victor N.; Bagratashvili, Nodar V.; Popov, Vladimir K.

    1997-06-01

    The paper presents theoretical and experimental results allowing to discuss and understand the mechanism of stress relaxation and reshaping of cartilage under laser radiation. A carbon dioxide and a Holmium laser was used for treatment of rabbits and human cartilage. We measured temperature, stress, amplitude of oscillation by free and forced vibration, internal friction, and light scattering in the course of laser irradiation. Using experimental data and theoretical modeling of heat and mass transfer in cartilaginous tissue we estimated the values of transformation heat, diffusion coefficients and energy activation for water movement.

  1. Holmium: YAG laser-induced liquid jet knife: possible novel method for dissection.

    PubMed

    Nakagawa, Atsuhiro; Hirano, Takayuki; Komatsu, Makoto; Sato, Mariko; Uenohara, Hiroshi; Ohyama, Hideki; Kusaka, Yasuko; Shirane, Reizo; Takayama, Kazuyoshi; Yoshimoto, Takashi

    2002-01-01

    Making surgical incisions in vessel-rich organs without causing bleeding is difficult. Thus, it is necessary to develop new devices for this purpose, especially for surgery involving small vessels as in neurosurgery, where damage against even small cerebral vessels result in severe neurological deficits. A laser-induced liquid jet was generated by irradiating pulsed Holmium Yttrium-Aluminum-Garnet (Ho: YAG) laser (beams of 350 microseconds pulse width) within a copper tube (internal diameter, 1 mm) with pure water (150 ml /hour). Ho: YAG laser beams were irradiated through an optical fiber (core diameter, 0.4 mm). The influence of the input of laser energy, structure of the nozzle, and the stand-off distance between the optical fiber tip and nozzle exit on the jet velocity was measured by a high-speed video camera to evaluate controllability of jet. The effect on artificial organs made of 10 and 30%(w/v) gelatin, each of which represent features of soft tissue and blood vessels. Jet velocity increased in proportion to gain in laser energy input, and maximum penetration depth into 10%(w/v) gelatin was 35 mm by single exposure at 350 mJ/pulse without impairing a vessel model. Shapes of nozzle also modified jet velocity with optimal nozzle/tube area ratio of 0.25. The laser-induced liquid jet has excellent potential as a new tool for removing soft tissue without damaging vital structures. Copyright 2002 Wiley-Liss, Inc.

  2. Current role of lasers in the treatment of benign prostatic hyperplasia (BPH).

    PubMed

    Kuntz, Rainer M

    2006-06-01

    Evaluate the current role of lasers in the treatment of benign prostatic hyperplasia (BPH). The results of a MEDLINE search for randomised trials and case series of the last 5 yr and published review articles were analysed for the safety and efficacy of neodymium:yttrium aluminum garnet (Nd:YAG), potassium-titanyl-phosphate (KTP), and holmium (Ho):YAG laser prostatectomy. The analysis includes 12 reports on randomised clinical trials, 2 comparative studies, 10 review articles, and a total of >5000 patients. Laser treatment of BPH has evolved from coagulation to enucleation. Blood loss is significantly reduced compared with transurethral resection and open prostatectomy. Visual laser ablation of the prostate and interstitial laser coagulation cause coagulative necrosis with secondary ablation. Long postoperative catheterisation, unpredictable outcomes, and high reoperation rates have restricted the use of these techniques. Ablative/vaporising techniques have become popular again with the marketing of new high-powered 80-W KTP and 100-W Ho lasers. Vaporisation immediately removes obstructing tissue. Short-term results are promising, but large series, long-term results, and randomised trials are lacking. Holmium laser enucleation (HoLEP) allows whole lobes of the prostate to be removed, mimicking the action of the index finger in open prostatectomy. Prostates of all sizes can be operated on. It is at least as safe and effective as transurethral resection of the prostate and open prostatectomy, with significantly lower morbidity. It is the only laser procedure that provides a specimen for histologic evaluation. HoLEP appears to be a size-independent new "gold standard" in the surgical treatment of BPH.

  3. Improving Lifetime of Quasi-CW Laser Diode Arrays for Pumping 2-Micron Solid State Lasers

    NASA Technical Reports Server (NTRS)

    Amzajerdian, Farzin; Meadows, Byron L.; Baker, Nathaniel R.; Barnes, Bruce W.; Singh, Upendra N.; Kavaya, Michael J.

    2007-01-01

    Operating high power laser diode arrays in long pulse regime of about 1 msec, which is required for pumping 2-micron thulium and holmium-based lasers, greatly limits their useful lifetime. This paper describes performance of laser diode arrays operating in long pulse mode and presents experimental data on the active region temperature and pulse-to-pulse thermal cycling that are the primary cause of their premature failure and rapid degradation. This paper will then offer a viable approach for determining the optimum design and operational parameters leading to the maximum attainable lifetime.

  4. High-power and highly efficient diode-cladding-pumped holmium-doped fluoride fiber laser operating at 2.94 microm.

    PubMed

    Jackson, Stuart D

    2009-08-01

    A high-power diode-cladding-pumped Ho(3+), Pr(3+)-doped fluoride glass fiber laser is demonstrated. The laser produced a maximum output power of 2.5 W at a slope efficiency of 32% using diode lasers emitting at 1,150 nm. The long-emission wavelength of 2.94 microm measured at maximum pump power, which is particularly suited to medical applications, indicates that tailoring of the proportion of Pr(3+) ions can provide specific emission wavelengths while providing sufficient de-excitation of the lower laser level.

  5. Novel application of an established technique for removing a knotted ureteric stent

    PubMed Central

    Tempest, Heidi; Turney, Ben; Kumar, Sunil

    2011-01-01

    This report describes a case whereby a ureteric stent became knotted during removal and lodged within the upper ureter. The authors describe a novel minimally invasive technique to remove the knotted ureteric stent using the holmium laser. PMID:22701009

  6. Arthroscopic management of temporomandibular joint disc perforations and associated advanced chondromalacia by discoplasty and abrasion arthroplasty: a supplemental report.

    PubMed

    Quinn, J H; Stover, J D

    1998-11-01

    This article describes the results of treating temporomandibular joint (TMJ) articular disc perforation and advanced chondromalacia arthroscopically by the use of discoplasty and abrasion arthroplasty. Forty-four joints were treated in 25 patients (23 females and 2 males). Twenty-nine disc perforations were present, 24 joints had grade III chondromalacia (fibrillated cartilage), and 14 joints had grade IV chondromalacia (exposed bone). Surgical procedures included 14 abrasion arthroplasties and 24 motorized shavings or holmium laser vaporizations. Holmium laser discoplasty with mobilization was used in 29 joints. Patients were followed-up for an average of 40.8 months (11 to 74 months). Preoperative pain on the visual analog scale (VAS) (1 to 10 cm) ranged from 5 to 10 cm, with an average of 7.4 cm. Postoperatively, nine patients had no pain and 16 patients had an average VAS of 2.7 cm (range, 1 to 5 cm). Preoperatively, 30 joints had clicking, and 14 joints had crepitation. Postoperatively, 25 joints had no noise, 12 joints had slight intermittent clicking, and seven joints had crepitation. The preoperative range of motion averaged 29.7 mm. Postoperatively, the range of motion averaged 37.7 mm (range, 33 to 42 mm). All patients could masticate a regular diet except hard food after an average of 40.8 months (11 to 74 months). These findings seem to justify the arthroscopic surgical procedures of discoplasty for disc perforations, motorized shaving, or holmium laser vaporization of grade III chondromalacia, and abrasion arthroplasty for bone exposure. The results also question the need for discectomy in the treatment of disc perforation.

  7. HO:LULF and HO:LULF Laser Materials

    NASA Technical Reports Server (NTRS)

    Barnes, Norman P. (Inventor); Morrison, Clyde A. (Inventor); Filer, Elizabeth D. (Inventor); Jani, Mahendra G. (Inventor); Murray, Keith E. (Inventor); Lockard, George E. (Inventor)

    1998-01-01

    A laser host material LULF (LuLiF4) is doped with holmium (Ho) and thulium (Tm) to produce a new laser material that is capable of laser light production in the vicinity of 2 microns. The material provides an advantage in efficiency over conventional Ho lasers because the LULF host material allows for decreased threshold and upconversion over such hosts as YAG and YLF. The addition of Tm allows for pumping by commonly available GaAlAs laser diodes. For use with flashlamp pumping, erbium (Er) may be added as an additional dopant. For further upconversion reduction, the Tm can be eliminated and the Ho can be directly pumped.

  8. Photoselective laser ablation of the prostate: a review of the current 2015 tissue ablation options.

    PubMed

    Tholomier, Côme; Valdivieso, Roger; Hueber, Pierre-Alain; Zorn, Kevin C

    2015-10-01

    Transurethral resection of the prostate (TURP) is still considered the gold standard to treat benign prostatic hyperplasia (BPH). However, photoselective vaporization of the prostate (PVP) has gained widespread acceptance as an alternative option requiring preoperative patient selection. Four laser systems are currently in use: holmium, thulium, diode and GreenLight. The goal of this article is to review the physics and the basics behind laser prostatectomies, as well as to present the most current literature concerning the results, advantages, disadvantages and international recommendations for each vaporization procedure. Holmium laser ablation of the prostate (HoLAP) and GreenLight photoselective vaporization of the prostate are an alternative to TURP for small to medium-sized prostates, providing equivalent efficacy and safety. GreenLight is also safe and effective in large-sized prostates and especially beneficial in anti-coagulated individuals compared to TURP. Thulium vaporization of the prostate (ThuVAP) and diode vaporization both require additional randomized trials and long term studies before conclusion is made, despite promising initial results. Diode vaporization provides the best hemostasis overall, but at the cost of increased complication and re-treatment rate, and thus is not recommended except in severely anti-coagulated patients. Laser vaporization is a safe and effective alternative to TURP in the treatment of benign prostatic hyperplasia (BPH) for carefully selected patients. However, further research is still needed to assess the durability of each technology.

  9. Restenosis of the coronary stenotic lesions treated by holmium:YAG laser coronary angioplasty

    NASA Astrophysics Data System (ADS)

    Miyazaki, Shunichi; Nonogi, Hiroshi; Goto, Yoichi; Itoh, Akira; Ozono, Keizaburo; Daikoku, Satoshi; Haze, Kazuo

    1994-07-01

    Clinical efficacy of newly developed Holmium YAG laser coronary angioplasty (HLCA) was assessed for 30 patients with angina. There were 12 near left main trunk (LMT) lesions and 4 aorto- ostial lesions. Adjunctive balloon angioplasty was performed for 25 of 30 lesions. Delivered energy ranged from 1.5 to 2.5 watts/pulse and the total exposure time ranged from 6 to 55 seconds. External diameter of laser catheter was 1.5 mm for 13 lesions, 1.4 mm for 17 lesions, and 1.7 mm for 5 lesions. Laser success, defined as 20% reduction of stenotic ratio, was obtained in 21 of 30 (70%) and overall procedural success rate was 93%. There were 3 cases with acute coronary occlusions relieved by adjunctive balloon angioplasty and one coronary perforation without manifestation of cardiac tamponade. There were no large coronary dissection which involved more than 5 mm of the coronary artery. Follow up coronary angiography after 3 months showed restenosis in 14 of 27 patients (52%). Percent stenosis after lasering (56%) was similar to that at 3 months after (62%). HLCA is acutely effective treatment for lesions near LMT, because of low incidence of large coronary dissection. However, angiographical restenosis rate is high at 3 months after HLCA. This may be attributed to the relatively large residual stenosis after the procedure and vessel injury caused by shock wave.

  10. Transurethral lithotripsy with holmium-YAG laser of a large exogenous prostatic calculus.

    PubMed

    Hasegawa, Masanori; Ohara, Rei; Kanao, Kent; Nakajima, Yosuke

    2011-04-01

    Prostatic calculi are classified into two types, endogenous and exogenous calculi, based on their origin. Endogenous calculi are commonly observed in elderly men; however, exogenous prostatic calculi are extremely rare. We report here the case of a 51-year-old man who suffered incontinence and pollakiuria with a giant exogenous prostatic calculus almost completely replacing the prostatic tissue. X-rays and computed tomography demonstrated a large calculus of 65 × 58 mm in the small pelvic cavity. The patient underwent a transurethral lithotripsy with a holmium-YAG laser and a total of 85 g of disintegrated stones was retrieved and chemical stone analysis revealed the presence of magnesium ammonium phosphate. The incontinence improved and the voiding volume increased dramatically, and no stone recurrence in the prostatic fossa occurred at the 2 years follow-up. The etiology of this stone formation seemed to be based on some exogenous pathways combined with urinary stasis and chronic urinary infection due to compression fracture of the lumbar vertebra.

  11. The "Body Mass Index" of Flexible Ureteroscopes.

    PubMed

    Proietti, Silvia; Somani, Bhaskar; Sofer, Mario; Pietropaolo, Amelia; Rosso, Marco; Saitta, Giuseppe; Gaboardi, Franco; Traxer, Olivier; Giusti, Guido

    2017-10-01

    To assess the "body mass index" (BMI) (weight and length) of 12 flexible ureteroscopes (digital and fiber optic) along with the light cables and camera heads, to make the best use of our instruments. Twelve different brand-new flexible ureteroscopes from four different manufacturers, along with eight camera heads and three light cables were evaluated. Each ureteroscope, camera head, and light cable was weighted; the total length of each ureteroscope, shaft, handle, flexible end-tip, and cable were all measured. According to our measurements (in grams [g]), the lightest ureteroscope was the LithoVue (277.5 g), while the heaviest was the URF-V2 (942.5 g). The lightest fiber optic endoscope was the Viper (309 g), while the heaviest was the Cobra (351.5 g). Taking into account the entirety of the endoscopes, the lightest ureteroscope was the Lithovue and the heaviest was the Wolf Cobra with the Wolf camera "3 CHIP HD KAMERA KOPF ENDOCAM LOGIC HD" (1474 g). The longest ureteroscope was the URF-P6 (101.6 cm) and the shortest was the LithoVue (95.5 cm); whereas the Viper and Cobra had the longest shaft (69 cm) and URF-V had the shortest shaft (67.2 cm). The URF-V2 had the longest flexible end-tip (7.6 cm), while the LithoVue had the shortest end-tip (5.7 cm) in both directions (up/down), while the URF-V had the shortest upward deflection (3.7 cm). Newer more versatile digital endoscopes were lighter than their traditional fiber optic counterparts in their entirety, with disposable endoscope having a clear advantage over other reusable ureteroscopes. Knowing the "BMI" of our flexible ureteroscopes is an important information that every endourologist should always take into consideration.

  12. Damage thresholds of silica fibers in holmium:YAG laser energy delivery for medical applications

    NASA Astrophysics Data System (ADS)

    Marolda, Matthew D.; Perrault, Donald F., Jr.; Pankratov, Michail M.; Shapshay, Stanley M.

    1993-07-01

    Pulsed Holmium:YAG (Ho:YAG) laser has been approved for some clinical applications and is under investigation for others. There is little published evidence on the durability or damage parameters for the fibers used in delivering energy from pulsed Ho:YAG laser. This study makes an initial attempt to investigate the damage threshold of different silica fibers under various conditions. Three types of fibers supplied by different manufacturers underwent laboratory testing. The overall finding of the study is that a new `perfect' fiber sustains no damage when fired without a target in air or in saline at energies up to 1.5 J/pulse and repetition rate up to 10 Hz. This study suggests that one may need to chose a fiber according to the clinical procedure to be performed: in cases where only soft tissue is to be manipulated - - any fiber may fare well, in cases where bone or calcified tissue is to be lased -- one may need fiber with aluminized or other hard coating. We also conclude that only professional refinishing with the removal of all exposed core-cladding material can insure trouble free performance.

  13. Improving Reliability of High Power Quasi-CW Laser Diode Arrays Operating in Long Pulse Mode

    NASA Technical Reports Server (NTRS)

    Amzajerdian, Farzin; Meadows, Byron L.; Barnes, Bruce W.; Lockard, George E.; Singh, Upendra N.; Kavaya, Michael J.; Baker, Nathaniel R.

    2006-01-01

    Operating high power laser diode arrays in long pulse regime of about 1 msec, which is required for pumping 2-micron thulium and holmium-based lasers, greatly limits their useful lifetime. This paper describes performance of laser diode arrays operating in long pulse mode and presents experimental data of the active region temperature and pulse-to-pulse thermal cycling that are the primary cause of their premature failure and rapid degradation. This paper will then offer a viable approach for determining the optimum design and operational parameters leading to the maximum attainable lifetime.

  14. Urologic laser types and instrumentation.

    PubMed

    Natalin, Ricardo A; Phillips, Courtney K; Clayman, Ralph V; Landman, Jaime

    2008-11-01

    Though the primary role of lasers in urology has always been in the treatment of urolithiasis, there are several other indications for their use. There are many different types of lasers currently available, each with unique properties conducive to treating certain disorders. As such, it is critical that today's urologist understands each laser's characteristics in order to optimize patient selection and treatment. The lasers which are primarily used in urologic applications include the carbon dioxide (CO2) laser; the Neodymium:Yttrium-Aluminum-Garnet (Nd:YAG); the Potassium Titanyl Phosphate (KTP) laser and the Holmium:YAG (Ho:YAG) laser. This review focuses on the unique characteristics of each of these lasers as well as the instrumentation needed utilize and deploy these tools in the urinary tract.

  15. Qualification Testing of Laser Diode Pump Arrays for a Space-Based 2-micron Coherent Doppler Lidar

    NASA Technical Reports Server (NTRS)

    Amzajerdian, Farzin; Meadows, Byron L.; Baker, Nathaniel R.; Barnes, Bruce W.; Singh, Upendra N.; Kavaya, Michael J.

    2007-01-01

    The 2-micron thulium and holmium-based lasers being considered as the transmitter source for space-based coherent Doppler lidar require high power laser diode pump arrays operating in a long pulse regime of about 1 msec. Operating laser diode arrays over such long pulses drastically impact their useful lifetime due to the excessive localized heating and substantial pulse-to-pulse thermal cycling of their active regions. This paper describes the long pulse performance of laser diode arrays and their critical thermal characteristics. A viable approach is then offered that allows for determining the optimum operational parameters leading to the maximum attainable lifetime.

  16. Laser-induced activation of regeneration processes in spine disc cartilage

    NASA Astrophysics Data System (ADS)

    Sobol, Emil N.; Vorobjeva, Natalia N.; Sviridov, Alexander P.; Omelchenko, Alexander I.; Baskov, Andrey V.; Shekhter, Anatoliy B.; Baskov, Vladimir A.; Feldchtein, Felix I.; Kamensky, Vladislav A.; Kuranov, Roman V.

    2000-05-01

    The effect of laser radiation on the regeneration processes in spine disk cartilage has been studied in-vivo. We used rabbits as a model and a Holmium (2.09 micrometer) and an Erbium fiber (1.56 micrometer) lasers for irradiation the discs which were preliminary opened to remove annulus fibrosus and the nucleus pulposus of the intervertebral disc. The irradiated zone has been examined using an optical coherent tomography in one month after the operation and conventional histological technique in two months after the laser operation. It has been shown that laser radiation promotes the growth of the new cartilaginous tissue of fibrous and hyaline types.

  17. Do We Really Need to Wear Proper Eye Protection When Using Holmium:YAG Laser During Endourologic Procedures? Results from an Ex Vivo Animal Model on Pig Eyes.

    PubMed

    Villa, Luca; Cloutier, Jonathan; Compérat, Eva; Kronemberg, Peter; Charlotte, Frederic; Berthe, Laurent; Rouchausse, Yann; Salonia, Andrea; Montorsi, Francesco; Traxer, Olivier

    2016-03-01

    We sought to evaluate the effect of holmium:yttrium-aluminum-garnet (Ho:YAG) laser exposure on ex vivo pig eyes and to test the protective action of different glasses in preventing eye lesions in case of accident. We pointed the tip of a Ho:YAG laser fiber from different distances (0, 3, 5, 8, 10, and 20 cm, respectively) toward the center of the pupil of the pig eye. The Ho:YAG laser was activated for 1 or 5 seconds at three different settings (0.5 J-20 Hz, 1 J-10 Hz, and 2 J-10 Hz, respectively). The experiment was repeated using laser safety glasses and eyeglasses. A total of 78 pig eyes were used. The effects of the Ho:YAG laser on pig eyes were assessed by histopathology. Comparable laser emission experiments were performed on thermal paper at different distances using different pulse energies. Ho:YAG laser-induced corneal lesions were observed in unprotected eyes, ranging from superficial burning lesions to full-thickness necrotic areas, and were directly related to pulse energy and time of exposure and inversely related to the distance from the eye. When the laser was placed 5 cm or more, no corneal damage was observed regardless of the laser setting and the time of exposure. Similar distance/energy level relationships were observed on thermal paper. No damage was observed to the lens or the retina in any of the Ho-YAG laser-treated eyes or in any of the eyes protected by laser safety and eyeglasses. Ho:YAG lasers can cause damage when set to high energy, but only to the cornea, from close distances (0-5 cm) and in the absence of eye protection. Eyeglasses are equally effective in preventing laser damage as laser safety glasses.

  18. Lande gJ factors for even-parity electronic levels in the holmium atom

    NASA Astrophysics Data System (ADS)

    Stefanska, D.; Werbowy, S.; Krzykowski, A.; Furmann, B.

    2018-05-01

    In this work the hyperfine structure of the Zeeman splitting for 18 even-parity levels in the holmium atom was investigated. The experimental method applied was laser induced fluorescence in a hollow cathode discharge lamp. 20 spectral lines were investigated involving odd-parity levels from the ground multiplet, for which Lande gJ factors are known with high precision, as the lower levels; this greatly facilitated the evaluation of gJ factors for the upper levels. The gJ values for the even-parity levels considered are reported for the first time. They proved to compare fairly well with the values obtained recently in a semi-empirical analysis for the even-parity level system of Ho I.

  19. An 8 cm long holmium-doped fiber saturable absorber for Q-switched fiber laser generation at 2-μm region

    NASA Astrophysics Data System (ADS)

    Rahman, M. F. A.; Dhar, A.; Das, S.; Dutta, D.; Paul, M. C.; Rusdi, M. F. M.; Latiff, A. A.; Dimyati, K.; Harun, S. W.

    2018-07-01

    We demonstrate a Q-switched all-fiber laser operating at 2-μm region by adding a piece of 8 cm long holmium doped fiber (HDF) as a fiber saturable absorber (SA) in Thulium doped fiber laser (TDFL) ring cavity. Doping of Ho ions into yttria-alumina silica glass was done through conventional Modified Chemical Vapor Deposition (MCVD) technique in conjunction with solution doping process. The fabricated HDF has a linear absorption of 3 dB with a core diameter and a numerical aperture of 10 μm and 0.18, respectively. A self-started Q-switching operation begins at 418 mW pump level and continually dominant until 564 mW pump level. As the pump power increases, stable pulse train presence from 30.61 kHz to 38.89 kHz while the pulse width reduces from 3.18 μs to 2.27 μs. Both maximum output power and maximum peak power are obtained at 5.05 mW and 57.2 mW, respectively, while the maximum pulse energy is calculated to be 129 nJ. The signal-to-noise ratio (SNR) of the fundamental frequency is 50 dB. Our work may contribute to the discovery of stable, robust, and economic SA for pulse fiber laser generation at 2-μm region.

  20. Percutaneous nephrostomy versus ureteroscopic management of sepsis associated with ureteral stone impaction: a randomized controlled trial.

    PubMed

    Wang, Chung-Jing; Hsu, Chi-Sen; Chen, Hung-Wen; Chang, Chien-Hsing; Tsai, Po-Chao

    2016-10-01

    A randomized trial was conducted prospectively to evaluate the efficacy, related complications, and convalescence of emergent retrograde ureteroscopic management, instead of percutaneous nephrostomy for decompression of the collecting system in cases of sepsis associated with ureteral stone obstruction. A total of 107 patients undergoing ureteroscopic stone manipulation for ureteral stones completed the study protocol, 53 patients in the percutaneous nephrostomy group, and 54 patients in the emergent retrograde ureteroscopic management group. The primary end point was the time to normalization of WBC of 10,000/mm or less and temperature of 37.4 °C or less. The second end point was the comparison analgesic consumption, length of stay, and related complications. Statistical analysis was performed using SPSS(®) version 14.0.1. The Mann-Whitney U test, Chi square test, and fisher's exact test was used as appropriate. The length of hospital stay (days) was 10.25 ± 3.53 and 8.24 ± 2.77 in the percutaneous nephrostomy group and emergent retrograde ureteroscopic management group, respectively, with significant difference (Table 2). However, patients in the emergent retrograde ureteroscopic management group had a significantly higher rate of s body temperature (°C). Meanwhile, the analgesic consumptions are 31.51 ± 11.16 and 40.00 ± 14.54 in the percutaneous nephrostomy group and emergent retrograde ureteroscopic management group, respectively, with significant difference. Our results show that it can be effectively and safely managed by retrograde ureteroscopic management combined with strong antibiotics in select clinical situations. Ureteroscopic management should no longer be considered a contraindication for the treatment of patients with sepsis associated with obstructing ureteral stones.

  1. Investigation of holmium-doped zirconium oxide ceramic phosphor as an ultraviolet wavelength-discriminating laser beam viewer

    NASA Astrophysics Data System (ADS)

    Yamanoi, Kohei; Hori, Tatsuhiro; Minami, Yuki; Empizo, Melvin John F.; Luong, Mui Viet; Shiro, Atsushi; Watanabe, Jun; Iwano, Keisuke; Iwasa, Yuki; Cadatal-Raduban, Marilou; Gabayno, Jacque Lynn; Shimizu, Toshihiko; Sarukura, Nobuhiko; Norimatsu, Takayoshi

    2018-01-01

    We report the fluorescence spectra of ZrO2 and trivalent Ho-doped ZrO2 ceramics under ultraviolet (UV) excitation at 213, 266, and 355 nm wavelengths. The Ho3+-doped ZrO2 ceramics exhibited varying fluorescence color tones depending on the excitation wavelength used. The different color tones match the fluorescence spectrum characteristics at each excitation wavelength. Our results demonstrate that Ho3+-doped ZrO2 ceramics can discriminate between UV light, specifically the third, fourth, and fifth harmonics of a Nd:YAG laser. It can potentially be used for developing UV laser beam viewers to aid laser alignment.

  2. Holmium:YAG thermokeratoplasty: treatment parameters for the correction of astigmatism based upon enucleated human eyes using an application mask

    NASA Astrophysics Data System (ADS)

    Kriegerowski, Martin; Rassmann, Katja; Oltrup, Theo; Bende, Thomas; Jean, Benedikt J.

    1995-05-01

    The refractive outcome of thermokeratoplasty depends upon the location and angle of the coagulation spots, applied with a focusing handpiece onto the corneal surface. Accuracy can be enhanced using a specially designed application mask. An astigmatism correction was performed on 10 human donor eyes (Holmium 25, Technomed, FRG, 15 Hz, 20 mJ/pulse, 25 pulses) with an optical zone of 8.1 mm, 5 eyes received a free hand laser application (marked positions) and the other 5 eyes were treated using a suctioned metal mask with drills for the handpiece (optical zone 8.1 mm). To compare the results a silicone replica was taken and analyzed by a confocal laser microtopometer. The refractive change for the steepest meridian was 10 D with a standard deviation of +/- 3.7 D for the free hand application. Using the application mask the refractive outcome was 9.8 D with a standard deviation of only 0.8 D. Using the application mask the standard deviation for the induced refractive change decreases by a factor of five.

  3. In-vivo study and histological examination of laser reshaping of cartilage

    NASA Astrophysics Data System (ADS)

    Sviridov, Alexander P.; Sobol, Emil N.; Bagratashvili, Victor N.; Omelchenko, Alexander I.; Ovchinnikov, Yuriy M.; Shekhter, Anatoliy B.; Svistushkin, Valeriy M.; Shinaev, Andrei A.; Nikiforova, G.; Jones, Nicholas

    1999-06-01

    The results of recent study of cartilage reshaping in vivo are reported. The ear cartilage of piglets of 8-12 weeks old have been reshaped in vivo using the radiation of a holmium laser. The stability of the shape and possible side effects have been examined during four months. Histological investigation shown that the healing of irradiated are could accompany by the regeneration of ear cartilage. Finally, elastic type cartilage has been transformed into fibrous cartilage or cartilage of hyaline type.

  4. Holmium Doped Solid State Laser Resonantly Pumped and Q-Switched by Novel GaSb-Based Photonic Devices

    DTIC Science & Technology

    2011-08-31

    increased overlap with p-cladding, presumably due to dominant role of inter valence band absorption [7]. Details of the conduction band structure of the...absorption to total loss. In the specific structures used here the n-cladding composition resulted into material with three valleys in conduction band to...materials. The beam properties of the high power 2 μm emitting GaSb -based diode lasers was improved by utilization of the waveguide structure with

  5. Temporal model of an optically pumped co-doped solid state laser

    NASA Technical Reports Server (NTRS)

    Wangler, T. G.; Swetits, J. J.; Buoncristiani, A. M.

    1993-01-01

    Currently, research is being conducted on the optical properties of materials associated with the development of solid state lasers in the two micron region. In support of this effort, a mathematical model describing the energy transfer in a holmium laser sensitized with thulium is developed. In this paper, we establish some qualitative properties of the solution of the model, such as non-negativity, boundedness, and integrability. A local stability analysis is then performed from which conditions for asymptotic stability are attained. Finally, we report on our numerical analysis of the system and how it compares with experimental results.

  6. Intensity noise coupling in soliton fiber oscillators.

    PubMed

    Wan, Chenchen; Schibli, Thomas R; Li, Peng; Bevilacqua, Carlo; Ruehl, Axel; Hartl, Ingmar

    2017-12-15

    We present an experimental and numerical study on the spectrally resolved pump-to-output intensity noise coupling in soliton fiber oscillators. In our study, we observe a strong pump noise coupling to the Kelly sidebands, while the coupling to the soliton pulse is damped. This behavior is observed in erbium-doped as well as holmium-doped fiber oscillators and confirmed by numerical modeling. It can be seen as a general feature of laser oscillators in which soliton pulse formation is dominant. We show that spectral blocking of the Kelly sidebands outside the laser cavity can improve the intensity noise performance of the laser dramatically.

  7. Electrokinetic lithotripsy: safety, efficacy and limitations of a new form of ballistic lithotripsy.

    PubMed

    Keeley, F X; Pillai, M; Smith, G; Chrisofos, M; Tolley, D A

    1999-08-01

    To investigate the safety and efficacy of electrokinetic lithotripsy (EKL), a ballistic lithotripter which uses high-energy magnetic fields to propel an impactor to fragment calculi. The records and radiographs of 121 patients who underwent ureteroscopy using the EKL for stones in the upper (26), mid (28) or lower (67) ureter were reviewed retrospectively. Ureteroscopy was performed with an 8.5 F semi-rigid ureteroscope, through which a 3 F EKL probe was passed. A total of 148 stones (mean stone size 11.5 mm, range 6-40) in 121 patients were treated using the EKL. One patient was lost to follow-up. Of 148 stones, 147 (99.3%) were fragmented, including five that had resisted fragmentation with either pulsed-dye laser or electrohydraulic lithotripsy. Despite this, only 45 of 56 patients (80%) with a single stone in the lower ureter were rendered stone-free after a single ureteroscopic procedure. Seven patients in this group (12%) required shock-wave lithotripsy for fragments that had been propelled into the kidney, while four patients (7%) required repeat ureteroscopy for retained ureteric fragments. Complications were limited to minor ureteric perforations in two patients, both of which were treated with a stent. EKL is an inexpensive and reliable endoscopic method which fragments nearly all urinary calculi. Its limitations include the propulsion of fragments and the need to use an offset, semi-rigid ureteroscope. We recommend the use of a basket or graspers to remove fragments of >/=4 mm after EKL.

  8. Comparison of Vela and holmium laser enucleation of the prostate: a retrospective clinical trial with a 12-month follow-up.

    PubMed

    Gu, Meng; Liu, Chong; Chen, Yan-Bo; Xu, Huan; Fu, Shi; Chen, Qi; Wang, Zhong

    2018-05-01

    This study aimed to estimate the validity and applicability of Vela laser enucleation of the prostate (VoLEP) in the management of benign prostatic hyperplasia (BPH). A retrospective chart review of 112 patients with BPH who underwent VoLEP (n = 60) or holmium laser enucleation of the prostate (HoLEP) (n = 56) was conducted at our institution from January 2015 to June 2015. The general and perioperative characteristics of the patients were collected. The 12-month follow-up data, including the lower urinary tract symptom (LUTS) indexes (International Prostate Symptom Score [I-PSS], quality-of-life [QoL] score and maximum flow rate [Qmax]), as well as rates of perioperative and late complications, were analyzed. No significant differences were observed in pre- and perioperative parameters, including operation time (58.05 ± 10.14 vs. 60.14 ± 12.30 min, P = 0.44), serum sodium decrease (3.49 ± 0.83 vs. 3.48 ± 0.84 mmol/L, P = 0.97), hemoglobin decrease (1.28 ± 0.38 vs. 1.24 ± 0.77 g/dL, P = 0.71), catheterization time (3.63 ± 1.10 vs. 3.89 ± 1.11 days, P = 0.21) and hospital stay (4.57 ± 1.25 vs. 4.68 ± 1.18 days, P = 0.63) between the two groups of patients. Compared with the HoLEP group, the noise during operation was lower in VoLEP group (47.22 ± 10.31 vs. 59.45 ± 9.65 db, P < 0.05). During 1, 6 and 12 months of follow-up visits, the LUTS indexes (I-PSS, QoL score and Qmax) were remarkably improved in both groups when comparing with the baseline values. Furthermore, LUTS indexes were comparable in both groups (P > 0.05). Similarly as the holmium laser, the Vela laser is a potent, safe, efficient durable and surgical treatment option for minimally invasive surgery in patients with BPH-induced LUTS.

  9. Fragmentation targeted at preferred discontinuities: A new concept in endolithotripsy with Holmium laser:YAG.

    PubMed

    Sánchez-Martín, F M; Emiliani, E; Pueyo-Morer, E; Angerri-Feu, O; Sanguedolce, F; Millán, F; Villavicencio, H

    2018-04-17

    There are currently 3holmium laser, YAG (Ho:YAG) endolithotripsy procedures that are considered basic (fragmentation, pulverisation, "pop-corn" technique). We present the technique of fragmentation targeted at preferred discontinuities (FTPD), a new concept of endolithotripsy by Ho:YAG laser. The FTPD technique is based on the selective application of energy (targeting a specific preselected point) to an area that is visually prone to the formation of a fracture line or preferred discontinuity (conditioned by the anisotropy of the urolithiasis). The ideal energy regimen (setting) is a high range of working energy (2-3J) with a very low frequency range (5-8Hz) and short pulse width. Between January 2015 to February 2017, the FTPD technique was used in 37 procedures (7 NLP, 16 RIRS, 12 URS, 2 cystolithotomies), with a Ho:YAG laser (Lumenis Pulse 120H ® , Tel-Aviv, Israel). Maximum power used: 24W (3J/8Hz) with fibres of 365μ and 273μ (URS, RIRS), and 32W (4J/8Hz) with fibres of 550μ (NLP, cystolithotomy). Strategic improvement was achieved in all cases using the TFPD technique to continue the endolithotripsy or remove fragments. No complications were recorded after the use of this method. FTPD can be considered a complementary option in combination with the basic methods of fragmentation and pulverisation. In our experience, it constitutes significant progress in optimising the performance of Ho:YAG laser endolithotripsy. Copyright © 2018 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Advances in Lasers for the Treatment of Stones-a Systematic Review.

    PubMed

    Kronenberg, Peter; Somani, Bhaskar

    2018-05-17

    Laser lithotripsy is increasingly used worldwide and is a continuously evolving field with new and extensive research being published every year. Variable pulse length Ho:YAG lithotripters allow new lithotripsy parameters to be manipulated, and there is an effort to integrate new technologies into lithotripters. Pulsed thulium lasers seem to be a viable alternative to holmium lasers. The performance of similar laser fibers varies from manufacturer to manufacturer. Special laser fibers and "cleaving only" fiber tip preparation can be beneficial for the lithotripsy procedure. Different laser settings and the surgical technique employed can have significant impact on the success of laser lithotripsy. When safely done, complications of laser lithotripsy are rare and concern the endoscopic nature of procedure, not the technology itself, making laser lithotripsy one of the safest tools in urology. Laser lithotripsy has had several new developments and more insight has been gained in recent years with many more advances expected in the future.

  11. Holmium laser urethrotomy for treatment of traumatic stricture urethra: a review of 78 patients.

    PubMed

    Hussain, Manzoor; Lal, Murli; Askari, Syed Hasan; Hashmi, Altaf; Rizvi, Syed Adibul Hasan

    2010-10-01

    To evaluate the efficacy and long-term results of laser urethrotomy as minimally invasive treatment for traumatic stricture urethra. Between January 2006 and June 2008, 78 male patients were treated with Holmium Laser urethrotomy. 16 Fr urethroscope was used through which 600um laser fiber was introduced through side channel. Stricture was visualized and incised at 12 o'clock position with energy set at 1500-2000 MJ at pulse rate of 10-12. Two other incisions were given at 2 and 10 o'clock positions. Further ablation was done till 16Fr Foley's catheter was passed. Patients were followed in a stricture clinic. Patients age ranged from 15-73 years. All strictures were due to trauma, Road traffic accident in 40 (52%) post catheter trauma 4 (5%), fall as ride 27 (35%) and failed urethroplasty 7 (8%). Site of stricture was bulbar 57 (73%), bulbomembranous 16 (20%) and membranoprostatic 5 (2.5%). Length of stricture ranged from 0.8-2.5 cms. At 3 months follow-up, 60 (77%) patients remained catheter and symptoms free while 18 (23%) developed recurrence of stricture but at the end of 36 months follow-up success rate decreased to 47 (60%). Among those who developed re-strictures, 6 ( 7.6%) had 2nd sitting laser while 4 (5.1%) had urethroplasty, and others were on intermittent dilatation. Immediate complications were sepsis 10 (13%), extravasation 2 (4%), failed urethrotomy 2 (4%) and mild haematuria 3 (5.8%). Hospital stay ranged from day care to 3 days. Laser urethrotomy is minimally invasive and an effective treatment for short strictures in bulbarurethra. The recurrence rate is 40% in the long-term follow-up and is more commonly seen in completely obliterated strictures.

  12. Robotically assisted ureteroscopy for kidney exploration.

    PubMed

    Talari, Hadi F; Monfaredi, Reza; Wilson, Emmanuel; Blum, Emily; Bayne, Christopher; Peters, Craig; Zhang, Anlin; Cleary, Kevin

    2017-02-01

    Ureteroscopy is a minimally invasive procedure for diagnosis and treatment of a wide range of urinary tract pathologies. It is most commonly performed in the diagnostic work-up of hematuria and the diagnosis and treatment of upper urinary tract malignancies and calculi. Ergonomic and visualization challenges as well as radiation exposure are limitations to conventional ureteroscopy. For example, for diagnostic tumor inspection, the urologist has to maneuver the ureteroscope through each of the 6 to 12 calyces in the kidney under fluoroscopy to ensure complete surveillance. Therefore, we have been developing a robotic system to "power drive" a flexible fiber-optic ureteroscope with 3D tip tracking and pre-operative image overlay. Our goal is to provide the urologist precise control of the ureteroscope tip with less radiation exposure. Our prototype system allows control of the three degrees of freedom of the ureteroscope via brushless motors and a joystick interface. The robot provides a steady platform for controlling the ureteroscope. Furthermore, the robot design facilitates a quick "snap-in" of the ureteroscope, thus allowing the ureteroscope to be mounted midway through the procedure. We have completed the mechanical system and the controlling software and begun evaluation using a kidney phantom. We put MRI-compatible fiducials on the phantom and obtained MR images. We registered these images with the robot using an electromagnetic tracking system and paired-point registration. The system is described and initial evaluation results are given in this paper.

  13. The Impact of Increased Bladder Blood Flow on Storage Symptoms after Holmium Laser Enucleation of the Prostate

    PubMed Central

    Ide, Hisamitsu; Aoki, Hiroaki; Muto, Satoru; Yamaguchi, Raizo; Tsujimura, Akira; Horie, Shigeo

    2015-01-01

    In order to investigate how holmium laser enucleation of the prostate (HoLEP) improves urinary storage symptoms, we assessed blood flow in the urinary bladder mucosa of patients with benign prostatic hyperplasia (BPH) before and after laser surgery. Seventy-four consecutive patients with BPH (median age 69 years, range; 53–88) underwent HoLEP at our institution and are included in this study. We prospectively assessed the International Prostate Symptom Score (IPSS), IPSS-QOL Score, the Overactive Bladder Symptom Score (OABSS), uroflowmetry, and blood flow in the urinary bladder, before and after surgery. Blood flow in the bladder mucosa was measured using the OMEGA FLOW (OMEGAWAVE, Tokyo, Japan) laser Doppler flowmeter. The median volume of the enucleated adenomas was 45.0 g (range: 25.0 to 83.2). The median IPSS improved significantly from 20 (range: 6–35) to 3 (0–22) (p<0.001; Wilcoxon signed-rank test), as did the storage symptoms score, which decreased from 13 (2–20) to 3 (1–8) (p<0.001). Median bladder blood flow increased at the trigone from 9.57±0.83 ml/sec to 17.60±1.08 ml/sec. Multiple regression analysis for the improved storage symptom score eliminated all explanatory variables except increased bladder perfusion. The data suggest that HoLEP improves blood flow in the bladder mucosa, which independently leads to the improvement of storage symptoms. PMID:26090819

  14. Watt-level short-length holmium-doped ZBLAN fiber lasers at 1.2  μm.

    PubMed

    Zhu, Xiushan; Zong, Jie; Wiersma, Kort; Norwood, R A; Prasad, Narasimha S; Obland, Michael D; Chavez-Pirson, Arturo; Peyghambarian, N

    2014-03-15

    In-band core-pumped Ho3+-doped ZBLAN fiber lasers at the 1.2 μm region were investigated with different gain fiber lengths. A 2.4 W 1190 nm all-fiber laser with a slope efficiency of 42% was achieved by using a 10 cm long gain fiber pumped at a maximum available 1150 nm pump power of 5.9 W. A 1178 nm all-fiber laser was demonstrated with an output power of 350 mW and a slope efficiency of 6.5%. High Ho3+ doping in ZBLAN is shown to be effective in producing single-frequency fiber lasers and short-length fiber amplifiers immune from stimulated Brillouin scattering.

  15. Digital ureteroscopes: technology update

    PubMed Central

    Gridley, Chad M; Knudsen, Bodo E

    2017-01-01

    The field of ureteroscopy has undergone a continual evolution since the first ureteroscopes were introduced. Over the past 10 years, we have entered into the digital era of ureteroscopy with both semirigid and flexible options becoming available. The following review looks at the benefits and drawbacks of digital flexible ureteroscopes as well as the current commercially available options. PMID:28203551

  16. Widely tunable short-infrared thulium and holmium doped fluorozirconate waveguide chip lasers.

    PubMed

    Lancaster, D G; Gross, S; Withford, M J; Monro, T M

    2014-10-20

    We report widely tunable (≈ 260 nm) Tm(3+) and Ho(3+) doped fluorozirconate (ZBLAN) glass waveguide extended cavity lasers with close to diffraction limited beam quality (M(2) ≈ 1.3). The waveguides are based on ultrafast laser inscribed depressed claddings. A Ti:sapphire laser pumped Tm(3+)-doped chip laser continuously tunes from 1725 nm to 1975 nm, and a Tm(3+)-sensitized Tm(3+):Ho(3+) chip laser displays tuning across both ions evidenced by a red enhanced tuning range of 1810 to 2053 nm. We also demonstrate a compact 790 nm diode laser pumped Tm(3+)-doped chip laser which tunes from 1750 nm to 1998 nm at a 14% incident slope efficiency, and a beam quality of M(2) ≈ 1.2 for a large mode-area waveguide with 70 µm core diameter.

  17. Ureteroscopy from the recent past to the near future.

    PubMed

    Reis Santos, José Manuel

    2018-02-01

    Stone surgery is one of oldest surgical practices undertaken by man. Hippocrates refused to let his followers "cut for the stone" and it was only in February 1980, when the first human trial of shock wave therapy on a renal stone was performed with success that a new era in minimally invasive treatment (surgery) for stones was opened up and this condemnation was finally resolved in the Hippocratic Oath. Endoscopy, using natural orifices, supported by anaesthesia, incremented by technology and with access to all points along the urinary tract, began by competing with ESWL, but is now the treatment of choice in most cases. As far as we know humans have always had stones. First, lithiasis was endemic bladder stones in children, now it is renal in general. Added to this a number of well-known risk factors, a rapid increase in obesity in the population, as well as bariatric surgery for its treatment, are causing an increase in the prevalence and recurrence of lithiasis everywhere. A short history of the advances made with the introduction and development of the ureteroscope, along with auxiliary devices, will show why this is the preferred technique at the moment for treating lithiasis in general and for treating stones in pregnant women, children and the obese in particular. Being a minimally invasive surgery, with a low morbidity and a very high efficiency and stonefree rate, has become established as a clear future technique for both adults and children. This development is not only due to technological advancements, but also to the routine use of the Holmium: YAG LASER for intracorporeal lithotripsy, capable of destroying any stone regardless of its composition or location, surpassing the ability of any other lithotripter. It is also due to the development of devices that allow access to the ureter and all parts of the kidney, as well as auxiliary aids to assist in the handling of stones during treatment. New LASERs, robotic control of the fdURS and digital imaging, as well as disposable devices, have had and, indeed, continue to have a unique impact on future development in this field. However, success will continue to depend on the careful choice of fURS, energy source and ancillary instruments obtained by the urologist during both real life and virtual training in human simulators.

  18. Robotically assisted ureteroscopy for kidney exploration

    PubMed Central

    Talari, Hadi F.; Monfaredi, Reza; Wilson, Emmanuel; Blum, Emily; Bayne, Christopher; Peters, Craig; Zhang, Anlin; Cleary, Kevin

    2018-01-01

    Ureteroscopy is a minimally invasive procedure for diagnosis and treatment of a wide range of urinary tract pathologies. It is most commonly performed in the diagnostic work-up of hematuria and the diagnosis and treatment of upper urinary tract malignancies and calculi. Ergonomic and visualization challenges as well as radiation exposure are limitations to conventional ureteroscopy. For example, for diagnostic tumor inspection, the urologist has to maneuver the ureteroscope through each of the 6 to 12 calyces in the kidney under fluoroscopy to ensure complete surveillance. Therefore, we have been developing a robotic system to “power drive” a flexible fiber-optic ureteroscope with 3D tip tracking and pre-operative image overlay. Our goal is to provide the urologist precise control of the ureteroscope tip with less radiation exposure. Our prototype system allows control of the three degrees of freedom of the ureteroscope via brushless motors and a joystick interface. The robot provides a steady platform for controlling the ureteroscope. Furthermore, the robot design facilitates a quick “snap-in” of the ureteroscope, thus allowing the ureteroscope to be mounted midway through the procedure. We have completed the mechanical system and the controlling software and begun evaluation using a kidney phantom. We put MRI-compatible fiducials on the phantom and obtained MR images. We registered these images with the robot using an electromagnetic tracking system and paired-point registration. The system is described and initial evaluation results are given in this paper. PMID:29731536

  19. Comparison of holmium:YAG and thulium fiber laser lithotripsy: ablation thresholds, ablation rates, and retropulsion effects.

    PubMed

    Blackmon, Richard L; Irby, Pierce B; Fried, Nathaniel M

    2011-07-01

    The holmium:YAG (Ho:YAG) laser lithotriptor is capable of operating at high pulse energies, but efficient operation is limited to low pulse rates (∼10 Hz) during lithotripsy. On the contrary, the thulium fiber laser (TFL) is limited to low pulse energies, but can operate efficiently at high pulse rates (up to 1000 Hz). This study compares stone ablation threshold, ablation rate, and retropulsion for the two different Ho:YAG and TFL operation modes. The TFL (λ = 1908 nm) was operated with pulse energies of 5 to 35 mJ, 500-μs pulse duration, and pulse rates of 10 to 400 Hz. The Ho:YAG laser (λ = 2120 nm) was operated with pulse energies of 30 to 550 mJ, 350-μs pulse duration, and a pulse rate of 10 Hz. Laser energy was delivered through 200- and 270-μm-core optical fibers in contact mode with human calcium oxalate monohydrate (COM) stones for ablation studies and plaster-of-Paris stone phantoms for retropulsion studies. The COM stone ablation threshold for Ho:YAG and TFL measured 82.6 and 20.8 J∕cm(2), respectively. Stone retropulsion with the Ho:YAG laser linearly increased with pulse energy. Retropulsion with TFL was minimal at pulse rates less than 150 Hz, then rapidly increased at higher pulse rates. For minimal stone retropulsion, Ho:YAG operation at pulse energies less than 175 mJ at 10 Hz and TFL operation at 35 mJ at 100 Hz is recommended, with both lasers producing comparable ablation rates. Further development of a TFL operating with both high pulse energies of 100 to 200 mJ and high pulse rates of 100 to 150 Hz may also provide an alternative to the Ho:YAG laser for higher ablation rates, when retropulsion is not a primary concern.

  20. Holmium Doped Solid State Laser Resonantly Pumped and Q-Switched by Novel GaSb-Based Photonic Devices

    DTIC Science & Technology

    2011-08-31

    dominant role of inter valence band absorption [7]. Details of the conduction band structure of the particular 0 20 40 60 80 100 0 10 20 30 CW 30s...here the n-cladding composition resulted into material with three valleys in conduction band to have almost the same energy minimum so no inter...emitting GaSb -based diode lasers was improved by utilization of the waveguide structure with asymmetric claddings. The AlGaAsSb p-cladding contained

  1. Acoustic transients in pulsed holmium laser ablation: effects of pulse duration

    NASA Astrophysics Data System (ADS)

    Asshauer, Thomas; Delacretaz, Guy P.; Jansen, E. Duco; Welch, Ashley J.; Frenz, Martin

    1995-01-01

    The goal of this work was to study the influence of pulse duration on acoustic transient generation in holmium laser ablation. For this, the generation and collapse of cavitation bubbles induced by Q-switched and free-running laser pulses delivered under water were investigated. Polyacrylamide gel of 84% water content served as a model for soft tissue. This gel is a more realistic tissue phantom than water because it mimics not only the optical properties but also the mechanical properties of tissue. The dynamics of bubble formation inside the clear gel were observed by 1 ns time resolved flash videography. A polyvinylidenefluoride (PVDF) needle probe transducer measured absolute values of pressure amplitudes. Pressure wave generation by cavitation bubble collapse was observed in all phantoms used. Maximum pressures of more than 180 bars at 1 mm from the collapse center were observed in water and high water-contents gels with a pulse energy of 200 mJ and a 400 micrometers fiber. A strong dependency of the bubble collapse pressure on the pulse duration for constant pulse energy was observed in gel as well as in water. For pulse durations longer than 400 microsecond(s) a 90% reduction of pressure amplitudes relative to 100 microsecond(s) pulses was found. This suggests that optimization of pulse duration offers a degree of freedom allowing us to minimize the risk of acoustical damage in medical applications like arthroscopy and angioplasty.

  2. Evidence-based outcomes of holmium laser enucleation of the prostate.

    PubMed

    Large, Tim; Krambeck, Amy E

    2018-05-01

    Holmium laser enucleation of the prostate (HoLEP) has been a mainstay therapy for the treatment of lower urinary tract symptoms (LUTS) secondary to benign prostate hyperplasia (BPH) for nearly 20 years. We briefly review current and sentinel publications that provide outcomes data after HoLEP. Current literature continues to support HoLEP as a versatile and durable surgical option for men with LUTS secondary to BPH. Despite evidence supporting durable symptom relief beyond 10 years even in large prostate glands, HoLEP is still not widely available to all patients. Concerns surrounding the learning curve of the procedure, high rates of retrograde ejaculation, and transient urinary incontinence seem to persist and limit the adoption of HoLEP by established urologists and residency training programs. Recent publications continue to show excellent short-term and long-term outcomes after HoLEP, in the categories of voiding function and patient satisfaction. Continued attempts to demonstrate equivalent outcomes of alternate-BPH surgical techniques are being met with renewed efforts by those performing HoLEP to demonstrate equivalent outcomes and patient safety during the learning phase of HoLEP for both mentored and self-directed surgical training.

  3. Titanium Dioxide (TiO2) film as a new saturable absorber for generating mode-locked Thulium-Holmium doped all-fiber laser

    NASA Astrophysics Data System (ADS)

    Mohd Rusdi, Muhammad Farid; Latiff, Anas Abdul; Paul, Mukul Chandra; Das, Shyamal; Dhar, Anirban; Ahmad, Harith; Harun, Sulaiman Wadi

    2017-03-01

    We report the generation of mode-locked thulium-holmium doped fiber laser (THDFL) at 1979 nm. This is a first demonstration of mode-locked by using Titanium Dioxide (TiO2) film as a saturable absorber (SA). A piece of 1 mm×1 mm TiO2 film was sandwiched in between two fiber ferrule in the cavity. Fabrication process of TiO2 film incorporated a TiO2 and a polyvinyl alcohol (PVA). The stable 9 MHz repetition rate of mode-locked mode operation with 58 dB SNR was generated under pump power of 902-1062 mW. At maximum pump power, the mode-locked THDFL has output power and pulse energy of 15 mW and 1.66 nJ, respectively. Our results demonstrate the TiO2 can be used promisingly in ultrafast photonics applications.

  4. Review of Current Laser Therapies for the Treatment of Benign Prostatic Hyperplasia

    PubMed Central

    Choi, Benjamin B.

    2013-01-01

    The gold standard for symptomatic relief of bladder outlet obstruction secondary to benign prostatic hyperplasia has traditionally been a transurethral resection of the prostate (TURP). Over the past decade, however, novel laser technologies that rival the conventional TURP have multiplied. As part of the ongoing quest to minimize complications, shorten hospitalization, improve resection time, and most importantly reduce mortality, laser prostatectomy has continually evolved. Today, there are more variations of laser prostatectomy, each with several differing surgical techniques. Although abundant data are available confirming the safety and feasibility of the various laser systems, future randomized-controlled trials will be necessary to verify which technique is superior. In this review, we describe the most common modalities used to perform a laser prostatectomy, mainly, the holmium laser and the potassium-titanyl-phosphate lasers. We also highlight the physical and clinical characteristics of each technology with a review of the most current and highest-quality literature. PMID:23789041

  5. Preventing stone retropulsion during intracorporeal lithotripsy.

    PubMed

    Elashry, Osama M; Tawfik, Ahmad M

    2012-12-01

    Several studies of ureteroscopic treatment for ureteral stones have reported that most stone clearance failures can be attributed to stone fragment retropulsion. Stone retropulsion can result in increased operative time and cost-resulting from the need to change from the semi-rigid ureteroscope to a flexible instrument to chase migrated calculi-and additional procedures to treat residual migrated fragments are often required. The degree of migration depends mainly on the energy source used for lithotripsy; pneumatic and electrohydraulic lithotripters are associated with a greater degree of retropulsion than lasers. Different stone-trapping strategies and devices have been developed to minimize stone migration. Novel devices include the Lithovac(®) suction device, the Passport(™) balloon, the Stone Cone(™), the PercSys Accordion(®), the NTrap(®), and stone baskets such as the LithoCatch(™), the Parachute(™), and the Escape(®). Some authors have also reported on the use of lubricating jelly and BackStop(®) gel (a reverse thermosensitive polymeric plug); these devices are instilled proximal to the stone prior to the application of kinetic energy in order to prevent retrograde stone migration.

  6. Minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy for calculus in bladder diverticula

    PubMed Central

    GU, SI-PING; YOU, ZHI-YUAN; HUANG, YUNTENG; LU, YI-JIN; HE, CAOHUI; CAI, XIAO-DONG; ZHOU, XIAO-MING

    2013-01-01

    The aim of this study was to investigate the effectiveness of minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy for treating calculus in bladder diverticula. Percutaneous cystostomy with ureteroscopic pneumatic lithotripsy was performed on six elderly male patients with calculi in bladder diverticula, who could not be treated with transurethral ureteroscopic lithotripsy. The stones were successfully removed from all patients, with no complications such as bladder perforation, rupture, urethritis or cystitis. The surgery time was 15–60 min, with an average time of 32 min. Postoperative ultrasound or X-ray examination showed no stone residues and the bladder stoma healed well. No recurrent stones were detected in the follow-up of 3–24 months (average, 16 months). Minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy is a safe, efficient and easy treatment for calculus in bladder diverticula. This method provides a new clinical approach for lithotripsy and we suggest that it is worthy of wider use. PMID:23837044

  7. Carbon Nanotube Mode-Locked Thulium Fiber Laser With 200 nm Tuning Range

    PubMed Central

    Meng, Yafei; Li, Yao; Xu, Yongbing; Wang, Fengqiu

    2017-01-01

    We demonstrated a mode-locked thulium/holmium (Tm/Ho) fiber laser continuously tunable across 200 nm (from 1860 nm to 2060 nm), which to the best of our knowledge represents the widest tuning range ever achieved for a passively mode-locked fiber laser oscillator. The combined use of a broadband carbon nanotube (CNT) saturable absorber and a diffraction grating mirror ensures ultra-broad tuning range, superb stability and repeatability, and makes the demonstrated laser a highly practical source for spectroscopy, imaging and optical communications. The laser emits <5 ps pulses with an optical spectral bandwidth of ∼3 nm across the full tuning range. Our results indicate that carbon nanotubes can be an excellent saturable absorber for achieving gain-bandwidth-limited tunable operation for 2 μm thulium fiber lasers. PMID:28322327

  8. Carbon Nanotube Mode-Locked Thulium Fiber Laser With 200 nm Tuning Range

    NASA Astrophysics Data System (ADS)

    Meng, Yafei; Li, Yao; Xu, Yongbing; Wang, Fengqiu

    2017-03-01

    We demonstrated a mode-locked thulium/holmium (Tm/Ho) fiber laser continuously tunable across 200 nm (from 1860 nm to 2060 nm), which to the best of our knowledge represents the widest tuning range ever achieved for a passively mode-locked fiber laser oscillator. The combined use of a broadband carbon nanotube (CNT) saturable absorber and a diffraction grating mirror ensures ultra-broad tuning range, superb stability and repeatability, and makes the demonstrated laser a highly practical source for spectroscopy, imaging and optical communications. The laser emits <5 ps pulses with an optical spectral bandwidth of ˜3 nm across the full tuning range. Our results indicate that carbon nanotubes can be an excellent saturable absorber for achieving gain-bandwidth-limited tunable operation for 2 μm thulium fiber lasers.

  9. Clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy for large impacted proximal ureteral calculi: a prospective, randomized study.

    PubMed

    Qi, Shiyong; Li, Yanni; Liu, Xu; Zhang, Changwen; Zhang, Hongtuan; Zhang, Zhihong; Xu, Yong

    2014-09-01

    To evaluate the clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy (POBC-URSL) for large impacted proximal ureteral calculi. 156 patients with impacted proximal ureteral stones ≥1.5 cm in size were randomized to ureteroscopic lithotripsy (URSL), POBC-URSL, and percutaneous nephrolithotomy (PNL) group between May 2010 and May 2013. For URSL, the calculi were disintegrated with the assistance of anti-retropulsion devices. POBC-URSL was performed with the assistance of an 8F percutaneous occlusive balloon catheter. PNL was finished with the combination of an ultrasonic and a pneumatic lithotripter. A flexible ureteroscope and a 200 μm laser fiber were used to achieve stone-free status to a large extent for each group. Variables studied were mean operative time, auxiliary procedure, postoperative hospital stay, operation-related complications, stone clearance rate, and treatment costs. The mean lithotripsy time for POBC-URSL was shorter than URSL, but longer than PNL (42.6±8.9 minutes vs 66.7±15.3 minutes vs 28.1±6.3 minutes, p=0.014). The auxiliary procedure rate and postoperative fever rate for POBC-URSL were significantly lower than URSL and comparable to PNL (p<0.01, p=0.034). POBC-URSL was superior to URSL with regard to the stone clearance rate at 3 days postoperatively, and as good as PNL (98.1% vs 75.0% vs 96.2%, p<0.01). The postoperative hospital stay and hematuria rate were lower in POBC-URSL group than PNL group and similar to URSL group (p=0.016, p<0.01). The treatment costs were lowest in POBC-URSL group ($1205.0±$113.9 vs $1731.7±$208.1 vs $2446.4±$166.4, p=0.004). For large impacted proximal ureteral calculi, POBC-URSL was associated with a higher stone clearance rate, fewer complications and costs. POBC-URSL combined the advantages of URSL and PNL.

  10. Ureteroscopy and laser stone fragmentation (URSL) for large (≥1 cm) paediatric stones: Outcomes from a university teaching hospital.

    PubMed

    Featherstone, N C; Somani, B K; Griffin, S J

    2017-04-01

    The treatment of large renal stones (≥1 cm) in paediatric patients is challenging. The usual treatment options include percutaneous nephrolithotomy (PCNL) or shockwave lithotripsy (SWL). There is a rise in the use of ureteroscopy and laser stone fragmentation (URSL) for paediatric stones; however, outcomes of treatment for large renal stones in this age group are still largely unknown. To investigate the outcome of URSL for large paediatric renal stones ≥1 cm treated at the present institution over the last 5 years. A retrospective review was performed of outcomes from the prospectively maintained stone database. Only paediatric patients undergoing ureteroscopic (rigid or flexible ureteroscopy (URS)) procedures for stones ≥1 cm were included. Patient demographics, operative details, stone burden, hospital stay, complications and stone clearance were recorded and analysed. From April 2010 to June 2015, 18 paediatric patients with a mean age of 10.4 years (range 3.6-15) underwent 35 ureteroscopic procedures for large stones (≥1 cm). The stone location was in the kidney (n = 14), ureter (n = 1), and in both the kidney and ureter for the remaining three patients. Nine patients had multiple stones. There was a preceding history of PCNL in four patients, with one patient having URS combined with a PCNL. The mean follow-up was 2.7 years (range 0-5). A postoperative stent was inserted in 21 (60%) patients. The overall stone-free rate (SFR) was 89% for a mean of 1.8 procedures per patient (range 1-4) - see Summary Table below. There was an inability to access stone within a lower pole calyx in one patient, despite maximum deflection of the ureteroscope. No intra- or post-operative complications were noted, and mean hospital stay was 1.1 days (range 0-5). Published papers in adult literature have shown that ureteroscopy and laser fragmentation (URSL) is a viable alternative to PCNL. Newer equipment and improved techniques have resulted in SFRs being comparable with PCNL. A recent systematic review reported an SFR of 91% for large adult stones (>2 cm) for a mean 1.45 procedures per patient, and an overall complication rate of 8.6%. The present study has also demonstrated excellent outcomes in the use of ureteroscopy and laser fragmentation for the management of large paediatric stones with no complications. The results show that paediatric URSL for large stones achieves a good SFR with minimal morbidity and is a good treatment option in established endourological units. Copyright © 2016. Published by Elsevier Ltd.

  11. Structural and optical properties of α-Fe2O3 nanoparticles, influence by holmium ions

    NASA Astrophysics Data System (ADS)

    Mathevula, L. E.; Noto, L. L.; Mothudi, B. M.; Dhlamini, M. S.

    2018-04-01

    α-Fe2O3 and α-Fe2O3 doped with different concentration of holmium ions were synthesized by a simple sol-gel method. The XRD data confirmed the hexagonal structure of α-Fe2O3 for un-doped and holmium doped samples. The crystallite size was found to be decreasing with increasing holmium concentration. The amount of holmium was quantified using an EDS, which shows an increase in holmium quantity as concentration increases. The UV-Vis measurement shows an absorption edge around 570 nm. The band gap was estimated using the Kubelka-Munk relation and it was found to be fluctuating between 1.94 eV and 2.04 eV. The PL spectra confirmed the effect of holmium ions on luminescence properties of α-Fe2O3 which showed a maximum intensity at 0.1 mol% Holmium, and quenching as the concentration is increased from 0.3 mol% to 0.9 mol%.

  12. Comparison of a 4.5 F semi-rigid ureteroscope with a 7.5 F rigid ureteroscope in the treatment of ureteral stones in preschool-age children.

    PubMed

    Atar, Murat; Sancaktutar, Ahmet Ali; Penbegul, Necmettin; Soylemez, Haluk; Bodakci, Mehmet Nuri; Hatipoglu, Namik Kemal; Bozkurt, Yasar; Cakmakci, Suleyman

    2012-12-01

    The aim of this study was to compare the success and complication rates of a 4.5 F ureteroscope with a 7.5 F ureteroscope in the treatment of urolithiasis in preschool-age children. We retrospectively reviewed 69 ureteroscopy (URS) procedures in a pediatric population (40 boys, 29 girls). We divided the patients into two groups according to the type of ureteroscope used: group 1 (n = 42, Storz 7.5 F) and group 2 (n = 27, Wolf 4.5 F). We statistically compared all the procedures performed in both groups regarding patient age, complication rates, whether the procedure was therapeutic, and whether we used a guidewire. Additionally, in cases with ureteral stones, we also compared the stone clearance rate and the necessity of X-ray imaging between the two groups. The mean patient age was 56.04 months in group 1 and 47.48 months in group 2 (p = 0.057). The stone-free rate was 78.6 % in group 1 and 92.6 % in group 2 (p > 0.05). However, when we compared the stone-free rates for patients younger than 3 years, the rate was 66.7 % in group 1 and 93.8 % in group 2 (p < 0.05). The difference was not statistically significant for patients between the ages of 4 and 7 years. The success and failure rates revealed better outcomes for treatment of ureteral stones with a 4.5 F ureteroscope. We recommend the use of the mini-ureteroscope, especially in infants and preschool-age children.

  13. Soft tissue effects of the THC:YAG laser on canine vocal cords.

    PubMed

    Kay, S L; Oz, M C; Haber, M; Blitzer, A; Treat, M R; Trokel, S L

    1992-09-01

    Recently, a laser based on a thulium-holmium-chromium (THC) doped Yttrium-aluminum-garnet (YAG) rod has been developed that produces light of 2.15 microns wavelength and can be transmitted through a low OH- silica fiberoptic cable. This wavelength falls on one of the peaks of the energy absorption spectrum of water. Thus, the THC:YAG laser eliminates the disadvantage of a cumbersome delivery system found in the CO2 laser while still providing precise cutting and minimal tissue injury inherent in lasers emitting light absorbed by water. We evaluated the soft tissue effects of this laser on canine vocal cords. Ablative lesions were produced by the THC:YAG laser and histologically examined on postoperative days 1, 7, and 28. Results indicate that the depth of tissue penetration is easily controlled and the healing response to tissue injury is comparable to that of the CO2 laser. The THC:YAG laser should prove to be a superior laser for use in otorhinolaryngology, especially when adapted to a flexible endoscope.

  14. Pneumatic ureteroscopic lithotripsy: is it still a reasonable treatment option for multiple ureteric stones?

    PubMed

    Isen, Kenan

    2012-01-01

    To assess the efficacy and safety of ureteroscopic pneumatic lithotripsy for multiple ureteric stones. 36 patients with multiple ureteric stones were treated with ureteroscopic lithotripsy (URSL). A 8/9.8-Fr Wolf semirigid ureteroscope and pneumatic lithotripter were used for stone fragmentation. 87 stones were treated with URSL. Successful fragmentation was achieved in 77 (88.5%) of the stones. The retreatment rate was 11.5%. The stone-free rate (SFR) of lower ureteric stones (93.3%) and middle ureteric stones (87.5%) was significantly higher compared with upper (73.3%) ureteric stones (p < 0.05). For patients with stones less than 1 cm and greater than 1 cm, the SFR was 91.5 and 75.0%, respectively (p < 0.05). Perforation occurred in 1 patient, mucosal injury occurred in 5 and stone migration in 5. No long-term complication was observed in any patient. Ureteroscopic pneumatic lithotripsy is still a reasonable treatment option for multiple ureteric stones. The procedure has high success rates with minimal morbidity. However, success rate can be affected by stone size and ureteric location. Copyright © 2012 S. Karger AG, Basel.

  15. Low-power holmium:YAG laser urethrotomy for treatment of urethral strictures: functional outcome and quality of life.

    PubMed

    Kamp, Stefan; Knoll, Thomas; Osman, Mahmoud M; Köhrmann, Kai Uwe; Michel, Maurice S; Alken, Peter

    2006-01-01

    To evaluate the efficacy of endourethrotomy with the holmium:YAG laser as a minimally invasive treatment for urethral stricture. Between January 2002 and January 2004, 32 male patients with symptomatic urethral strictures (8 bulbar, 9 penile, 9 combined) were treated with Ho:YAG-laser urethrotomy in our department. The stricture was iatrogenic in 60% (N = 18), inflammatory in 16.6% (N = 5), traumatic in 13.3% (N = 4), and idiopathic in 7% (N = 3). The stricture was incised under vision at the 12 o'clock location or the site of maximum scar tissue or narrowing in asymmetric strictures. Laser energy was set on 1200 to 1400 mJ with a frequency of 10 to 13 Hz. Postoperatively, drainage of the bladder was performed for 4 days using a 18F silicone catheter. Triamcinolone was instilled intraurethrally after removal of the catheter in all patients. Patients were followed up by mailed questionnaire, including International Prostate Symptom Score and quality of life. Retrograde endoscopic Ho:YAG laser urethrotomy could be performed in all 32 patients. Most patients (22; 68.7%) did not need any reintervention. Ten patients developed recurrent strictures that were treated by another laser urethrotomy in 4 patients (12.5%), while 6 patients (18.7%) needed open urethroplasty with buccal mucosa. Including 2 patients treated with repeat laser urethrotomy, 24 patients (75%) were considered successful after a mean follow-up of 27 months (range 13-38 months). No intraoperative complications were encountered, although in 5% of patients, a urinary-tract infection was diagnosed postoperatively. No gross hematuria occurred. The Ho:YAG laser urethrotomy is a safe and effective minimally invasive therapeutic modality for urethral stricture with results comparable to those of conventional urethrotomy. Further data from long-time follow-up are necessary to compare the success rate with that of conventional urethrotomy and urethroplasty. Nevertheless, the Ho:YAG laser urethrotomy might at least be an alternative to urethroplasty in patients with high comorbidity who are not suitable for open reconstruction.

  16. Stone formation from nonabsorbable clip migration into the collecting system after robot-assisted partial nephrectomy.

    PubMed

    Lee, Ziho; Reilly, Christopher E; Moore, Blake W; Mydlo, Jack H; Lee, David I; Eun, Daniel D

    2014-01-01

    We describe a case in which a Weck Hem-o-lok clip (Teleflex, Research Triangle Park, USA) migrated into the collecting system and acted as a nidus for stone formation in a patient after robot-assisted partial nephrectomy. The patient presented 2 years postoperatively with left-sided renal colic. Abdominal computed tomography scan showed a 10 millimeter renal calculus in the left middle pole. After using laser lithotripsy to fragment the overlying renal stone, a Weck Hem-o-lok clip was found to be embedded in the collecting system. A laser fiber through a flexible ureteroscope was used to successfully dislodge the clip from the renal parenchyma, and a stone basket was used to extract the clip.

  17. Comparison of Perioperative Outcomes Between Holmium Laser Enucleation of the Prostate and Robot-Assisted Simple Prostatectomy.

    PubMed

    Zhang, Mimi W; El Tayeb, Marawan M; Borofsky, Michael S; Dauw, Casey A; Wagner, Kristofer R; Lowry, Patrick S; Bird, Erin T; Hudson, Tillman C; Lingeman, James E

    2017-09-01

    To compare perioperative outcomes for patients undergoing holmium laser enucleation of the prostate (HoLEP) and robotic-assisted simple prostatectomy (RSP) for benign prostatic hypertrophy (BPH). Patient demographics and perioperative outcomes were compared between 600 patients undergoing HoLEP and 32 patients undergoing RSP at two separate academic institutions between 2008 and 2015. Patients undergoing HoLEP and RSP had comparable ages (71 vs 71, p = 0.96) and baseline American Urological Association Symptom Scores (20 vs 24, p = 0.21). There was no difference in mean specimen weight (96 g vs 110 g, p = 0.15). Mean operative time was reduced in the HoLEP cohort (103 minutes vs 274 minutes, p < 0.001). Patients undergoing HoLEP had lesser decreases in hemoglobin, decreased transfusions rates, shorter hospital stays, and decreased mean duration of catheterization. There was no difference in the rate of complications Clavien grade 3 or greater (p = 0.33). HoLEP and RSP are both efficacious treatments for large gland BPH. In expert hands, HoLEP appears to have a favorable perioperative profile. Further studies are necessary to compare long-term efficacy, cost, and learning curve influences, especially as minimally invasive approaches become more widespread.

  18. When is prior ureteral stent placement necessary to access the upper urinary tract in prepubertal children?

    PubMed

    Corcoran, Anthony T; Smaldone, Marc C; Mally, Dev; Ost, Michael C; Bellinger, Mark F; Schneck, Francis X; Docimo, Steven G; Wu, Hsi-Yang

    2008-10-01

    We studied the possibility that age, height, weight and body mass index could be used to predict the likelihood of successful ureteroscopic access to the upper urinary tract without previous stent placement in prepubertal children. We retrospectively reviewed all ureteroscopic procedures for upper tract calculi in prepubertal children from 2003 to 2007. We compared age, height, weight and body mass index in patients who underwent successful primary flexible ureteroscopic access and in those who required initial stent placement to perform ureteroscopy. Successful primary ureteroscopic access to the upper tract was achieved in 18 of 30 patients (60%). There was no difference in mean age (9.9 vs 9.5 years, p = 0.8), height (132 vs 128 cm, p = 0.6), weight (37 vs 36 kg, p = 0.86) or body mass index (19.3 vs 20.5 kg/m(2), p = 0.55) between patients with successful vs unsuccessful upper tract access. Locations that prevented access to the upper urinary tract were evenly distributed among the ureteral orifice, iliac vessels and ureteropelvic junction. Age, height, weight and body mass index could not predict the likelihood of successful ureteroscopic access to the upper tract. Placement of a ureteral stent for passive ureteral dilation is not necessary for successful ureteroscopic access to the renal pelvis in prepubertal children. An initial attempt at ureteroscopy, with placement of a ureteral stent if upper tract access is unsuccessful, decreases the number of procedures while maintaining a low complication rate.

  19. Pediatric ureteroscopic management of intrarenal calculi.

    PubMed

    Tanaka, Stacy T; Makari, John H; Pope, John C; Adams, Mark C; Brock, John W; Thomas, John C

    2008-11-01

    Data addressing ureteroscopic management of intrarenal calculi in prepubertal children are limited. We reviewed our experience from January 2002 through December 2007. We retrospectively reviewed ureteroscopic procedures for intrarenal calculi in children younger than 14 years. Stone-free status was determined with postoperative imaging. Multiple logistic regression analysis was used to assess the influence of preoperative factors on initial stone-free status and the need for additional procedures. Intrarenal calculi were managed ureteroscopically in 52 kidneys in 50 children with a mean age of 7.9 years (range 1.2 to 13.6). Mean stone size was 8 mm (range 1 to 16). Stone-free rate after a single ureteroscopic procedure was 50% (25 of 50 patients) on initial postoperative imaging and 58% (29 of 50) with extended followup. Initial stone-free status was dependent on preoperative stone size (p = 0.005) but not stone location. Additional stone procedures were required in 18 upper tracts. Younger patient age (p = 0.04) and larger preoperative stone size (p = 0.002) were associated with the need for additional procedures. Additional procedures were required in more than half of the stones 6 mm or larger but in no stone smaller than 6 mm. Ureteroscopy is a safe method for the treatment of intrarenal calculi in the prepubertal population. Our ureteroscopic stone-free rate for intrarenal stones is lower than that reported for ureteral stones. Parents should be informed that additional procedures will likely be required, especially in younger patients and those with stones larger than 6 mm.

  20. New laser treatment approaches for benign prostatic hyperplasia.

    PubMed

    Fried, Nathaniel M

    2007-01-01

    The recent introduction of higher power 100 W holmium:yttrium-aluminum-garnet (Ho:YAG) and 80 W potassium titanyl phosphate lasers for rapid incision and vaporization of the prostate has resulted in renewed interest in the use of lasers for treatment of benign prostatic hyperplasia (BPH). Although long-term studies are still lacking, short-term results demonstrate that these procedures are at least as safe and effective in relieving BPH symptoms as transurethral resection of the prostate and may provide reduced morbidity. Other laser techniques, such as interstitial laser coagulation and contact laser vaporization of the prostate, have lost popularity due to complications with increased catheterization time, irritative symptoms, and infection rates. Although Ho:YAG laser enucleation of the prostate is more difficult to learn and a slower procedure than potassium titanyl phosphate laser vaporization, the Ho:YAG laser is currently the most proven laser technique for BPH treatment. This article reviews the latest developments in laser treatment of BPH over the past 2 years and provides a view toward the future of lasers in the treatment of BPH.

  1. Fluoroscopic Placement of Double-Pigtail Ureteral Stents

    PubMed Central

    Chen, Gregory L.

    2001-01-01

    Purpose: Double-pigtail ureteral stent is placed cystoscopically after ureteroscopy. We describe a technique for fluoroscopic placement of ureteral stents and demonstrate its use in a non-randomized prospective study. Materials and methods: Double-pigtail stents were placed either fluoroscopically or cystoscopically in 121 consecutive patients. In the fluoroscopic method, the stent was placed over a guide wire using a stent pusher without the use of cystoscopy. Conversely, stents were placed through the working channel of the cystoscope under vision. The procedure, stent length, width, type, method, ureteral dilation, and use of a retrieval string were noted. Results: A wide range of stent sizes were used. The success with fluoroscopic placement of double-pigtail ureteral stents was 100% (89 of 89 cases). No stents migrated or required replacement. Stents were placed after ureteroscopic laser lithotripsy (53/89) and ureteroscopic tumor treatment (22/89). Cystoscopic visualization was used in 32 additional procedures requiring precise control (15 ureteral strictures and nine retrograde endopyelotomy). Conclusions: The fluoroscopic placement of ureteral stents is a safe and simple technique with a very high success rate. We have used cystoscopic placement only after incisional procedures such as retrograde endopyelotomy, stricture or ureterotomy. PMID:18493562

  2. A Prospective Randomized Comparison Between Shock Wave Lithotripsy and Flexible Ureterorenoscopy for Lower Caliceal Stones ≤2 cm: A Single-Center Experience.

    PubMed

    Kumar, Anup; Vasudeva, Pawan; Nanda, Biswajit; Kumar, Niraj; Das, Manoj Kumar; Jha, Sanjeev Kumar

    2015-05-01

    The optimal management method of lower caliceal calculi is still undefined. We performed a prospective randomized comparison to evaluate safety and efficacy of shock wave lithotripsy (SWL) and flexible ureteroscopy (RIRS) for lower caliceal calculus ≤2 cm. Between December 2011 and January 2012, 195 patients with single radio-opaque lower caliceal calculi ≤2 cm were included in the study. Randomization was done into two groups-group A: SWL performed as an outpatient procedure using the electromagnetic lithotripter (Dornier compact delta) and group B: RIRS was performed using the 6F/7.5F flexible ureteroscope (Richard Wolf) with holmium laser intracorporeal lithotripsy. Demographic characteristics, success, retreatment, and auxiliary procedure rates and complications were analyzed statistically. Of 195 patients, 97 and 98 patients were enrolled in group A and B, respectively. Mean stone size was 12.1 mm in group A vs 12.3 mm in group B (p=0.52). The overall 3 month stone-free rate was (74/90) 82.2% for group A vs (78/90) 86.6% for group B (p=0.34); for stones <10 mm, it was (45/55) 84.9% for group A vs (43/51) 87.7% for group B (p=0.32) and for 10-20 mm stones, it was (29/35) 78.4% for group A vs (35/39) 85.4% for group B (p=0.12). Retreatment rate was significantly greater in group A compared with group B (61.1% vs 11.1%; p<0.001). Auxiliary procedure rate was comparable (21.1% vs 17.7%; p=0.45). The complication rate was 6.6% in group A vs 11.1% in group B (p=0.21). Both SWL and RIRS are safe and efficacious for lower caliceal calculi ≤20 mm. For stones <10 mm, SWL was less invasive and safer than RIRS with efficacy comparable to it. However, for 10-20 mm stones, RIRS was more effective, with lesser retreatment rate.

  3. Mini-percutaneous Nephrolithotomy Under Total Ultrasonography in Patients Aged Less Than 3 Years: A Single-center Initial Experience from China

    PubMed Central

    Xiao, Bo; Zhang, Xin; Hu, Wei-Guo; Chen, Song; Li, Yu-Hong; Tang, Yu-Zhe; Liu, Yu-Bao; Li, Jian-Xing

    2015-01-01

    Background: Urolithiasis in pediatric population is a serious problem with the incidence increased these years. In the management of larger stones (diameters >2 cm), percutaneous nephrolithotomy (PCNL) is considered to be the gold standard. This study aimed to investigate the efficacy and safety of mini-PCNL under total ultrasonography in patients aged <3 years. Methods: We reviewed 68 patients (80 renal units) aged <3 years between August 2006 and December 2014 in Peking University People's Hospital and Beijing Tsinghua Changung Hospital, including 36 renal units with a single stone, 6 with staghorn stones, 14 with upper ureteral stones, and 24 with multiple stones. The mean age of the patients was 24.2 months (range 6–36 months), and the mean maximum stone diameter was 19.2 mm (range 10–35 mm). The puncture site selection and tract dilation were guided by Doppler ultrasonography solely. All procedures were performed using 12–16 Fr tracts. Stones were fragmented using pneumatic lithotripsy and a holmium laser with an 8/9.8 Fr rigid ureteroscope. Results: Fifty-six patients with unilateral stones underwent a single session procedure, and 12 patients with bilateral stones underwent two procedures. The mean time to establish access was 2.8 min (range 1.8–5.0 min), the mean operative time was 36.5 min (range 20–88 min), the mean decrease in hemoglobin concentration was 8.9 g/L (2–15 g/L), and the stone-free rate (SFR) at hospital discharge was 94.0%. The mean postoperative hospital stay was 7.1 days (range 3–13 days). Postprocedure complications included fever (>38.5°C) in five patients and reactive pleural effusion in one patient. Blood loss requiring transfusion, sepsis, adjacent organ injury, and kidney loss were not observed. Conclusions: This study indicated that ultrasound-guided mini-PCNL is feasible and safe in patients aged <3 years, without major complications or radiation exposure. PMID:26063360

  4. Dual comb generation from a mode-locked fiber laser with orthogonally polarized interlaced pulses.

    PubMed

    Akosman, Ahmet E; Sander, Michelle Y

    2017-08-07

    Ultra-high precision dual-comb spectroscopy traditionally requires two mode-locked, fully stabilized lasers with complex feedback electronics. We present a novel mode-locked operation regime in a thulium-holmium co-doped fiber laser, a frequency-halved state with orthogonally polarized interlaced pulses, for dual comb generation from a single source. In a linear fiber laser cavity, an ultrafast pulse train composed of co-generated, equal intensity and orthogonally polarized consecutive pulses at half of the fundamental repetition rate is demonstrated based on vector solitons. Upon optical interference of the orthogonally polarized pulse trains, two stable microwave RF beat combs are formed, effectively down-converting the optical properties into the microwave regime. These co-generated, dual polarization interlaced pulse trains, from one all-fiber laser configuration with common mode suppression, thus provide an attractive compact source for dual-comb spectroscopy, optical metrology and polarization entanglement measurements.

  5. Free-beam and contact laser soft-tissue ablation in urology.

    PubMed

    Tan, Andrew H H; Gilling, Peter J

    2003-10-01

    The ablation of tissue by laser has several applications in urology. Most of the published research has been concerned with the treatment of benign prostatic hyperplasia (BPH). Other applications studied include superficial upper- and lower-tract transitional-cell carcinoma, urethral and ureteral strictures, ureteropelvic junction stenosis, and posterior urethral valves. The attraction of laser ablation for the treatment of BPH lies with the decreased morbidity in comparison with standard transurethral electrocautery resection of the prostate and the ability to remove tissue immediately and therefore allow a more rapid progression to catheter removal and early voiding. The three main laser wavelengths used in urology for tissue ablation are the neodymium:yttrium-aluminum-garnet when used with contact tips or high-density power settings, the potassium-titanyl-phosphate, and the holmium:YAG. This article reviews the published literature on the use of these laser wavelengths in soft-tissue ablation, focusing on the treatment of BPH.

  6. In Vitro Comparison of Stone Fragmentation When Using Various Settings with Modern Variable Pulse Holmium Lasers.

    PubMed

    Bell, John Roger; Penniston, Kristina L; Nakada, Stephen Y

    2017-10-01

    There are limited data regarding optimal laser and energy settings during stone fragmentation. We assessed effects on fragmentation using a variety of energy and frequency settings with two laser systems. Artificial stones were created using BegoStone. A clear polyvinylchloride (PVC) tube with an inner diameter of 13 mm was closed at one end with a removable plug to create the in vitro ureteral and caliceal environments. The Lumenis Pulse 120H and the Cook Rhapsody H-30 holmium lasers were studied in the caliceal and ureteral models. A single urologist fragmented each stone to <2 mm. The caliceal studies assessed the time to fragmentation (n = 56). The ureteral studies measured the retropulsion distance of each stone phantom after 5 minutes of laser treatment time using different pulse width settings (n = 15). Complete treatment of the stone with the 120H required 10.9 minutes at ≥1 J vs 26.9 minutes at <1 J (p < 0.001). The H-30 showed similar results with treatment times of 11.2 minutes at ≥1 J vs 22.8 minutes at <1 J (p < 0.001). There was no significant difference in treatment time when comparing the two lasers using settings of 0.8 J × 8 Hz and 1.5 J × 10 Hz (25.5 minutes vs 24.8 minutes, p = 0.861; and 13.2 minutes vs 9.5 minutes, p = 0.061; respectively). Retropulsion distances using the 120H were 13.9 cm using long pulse, 25.2 cm using medium pulse, and 56.6 cm using short pulse. Retropulsion distances using the H-30 laser were 7 cm using long pulse and 14.5 cm using short pulse, which differed from the 120H (p < 0.001). Laser fragmentation was faster with both lasers when energy settings of ≥1 J were used. Treatment times using the 120H and the H-30 lasers were equivalent. Retropulsion distances were less with both lasers when longer pulse widths were used. The H-30 resulted in less stone retropulsion compared with the 120H.

  7. Doped sesquioxide ceramic for eye-safe solid state laser materials

    NASA Astrophysics Data System (ADS)

    Kim, Woohong; Baker, Colin; Florea, Catalin; Frantz, Jesse; Villalobos, Guillermo; Shaw, Brandon; Bowman, Steve; O'Connor, Shawn; Sadowski, Bryan; Hunt, Michael; Aggalwar, Ishwar; Sanghera, Jasbinder

    2013-03-01

    In this paper, we present our recent results in the development of Ho3+ doped sesquioxides for eye-safe solid state lasers. We have synthesized optical quality Lu2O3 nanopowders doped with concentrations of 0.1, 1.0, 2.0, and 5% Ho3+. The powders were synthesized by a co-precipitation method beginning with nitrates of holmium and lutetium. The nanopowders were hot pressed into optical quality ceramic discs. The optical transmission of the ceramic discs is excellent, nearly approaching the theoretical limit. The optical, spectral and morphological properties as well as the lasing performance from highly transparent ceramics are presented.

  8. Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate

    PubMed Central

    Maheshwari, Pankaj N.; Wagaskar, Vinayak G.; Maheshwari, Reeta P.

    2018-01-01

    Introduction: Holmium laser enucleation of the prostate (HoLEP) is a recognized option for the surgical management of benign prostatic hyperplasia. While the laser parameters and enucleation techniques have been widely studied, the morcellation techniques still remain under-evaluated. The current study evaluates the two commonly used morcellation devices for their in vivo efficiency and patient safety. Materials and Methods: A total of 222 patients who underwent HoLEP at two medical centres between January 2011 to December 2013 by a single surgeon were included. Of these 222 patients, the Richard Wolf Piranha Morcellation System, Germany (WM), was used on 140 patients, while on the remaining 82, the Lumenis® VersaCut™ Morcellator, Yokneam, Israel (LM), was used. These devices were compared for safety parameters such as the incidence of bladder mucosal injury, deep muscle injury, bladder perforation, and bleeding requiring electrocoagulation. The morcellation efficiency (ME) defined as the ratio of the weight of morcellated tissue in grams to the time required for morcellation in minutes was also compared. Results: The incidence of bladder mucosal injury, deep muscle injury, and bleeding requiring electrocoagulation was statistically significantly lower for the WM than the LM. None of the patients had a full-thickness bladder perforation with either of the morcellators. The ME was higher for the LM. In eight patients, hard, smooth rounded adenomatous nodules could not be morcellated by the WM and had to be crushed by a stone grasping forceps before morcellation. Conclusions: While the LM is a faster morcellator, WM has a better safety profile. PMID:29692508

  9. From novelty to the every-day: the evolution of ureteroscopy.

    PubMed

    Ridyard, Douglas; Dagrosa, Lawrence; Pais, Vernon M

    2016-12-01

    Ureteroscopy revolutionized the surgical approach to the upper urinary tract, and is well recognized as a cornerstone of modern urology. Although now commonplace, ureteroscopic equipment and techniques were truly revolutionary. A review of the innovations and innovators that developed ureteroscopic surgery sets the stage for a more thorough understanding of what can be done ureteroscopically, and may additionally better inform what limitations remain. Given that future advancements in urologic therapy will be dependent upon a similar pursuit of paradigm shifting improvements in disease management, an overview of the development of modern ureteroscopy may inspire such change.

  10. Significance of Ureteroscopic Biopsy Grade in Patients with Upper Tract Urothelial Carcinoma

    PubMed Central

    Furukawa, Junya; Miyake, Hideaki; Sakai, Iori; Fujisawa, Masato

    2013-01-01

    Background The objective of this study was to assess the significance of the ureteroscopic biopsy grade for patients with upper tract urothelial carcinoma (UTUC). Patients and Methods This study included 40 patients who were diagnosed with a single focus of UTUC by ureteroscopic biopsy and subsequently underwent nephroureterectomy. The significance of the biopsy grade as a predictive factor for pathological outcomes of nephroureterectomy was retrospectively analyzed. Results Of these 40 patients, 19 (47.5%) and 21 (52.5%) were diagnosed with low and high grade UTUC, respectively. The ureteroscopic biopsy grade matched the pathological grade of surgically resected specimens in 35 of the 40 cases (87.5%), and there was a significant correlation between the biopsy and pathological grades (p < 0.001). Furthermore, the biopsy grade was also shown to be closely associated with the pathological stage (p < 0.001); that is, only 1 of the 19 patients (5.3%) with biopsy low grade UTUC were pathologically diagnosed as having muscle invasive disease, while 17 of the 21 patients (81.0%) with biopsy high grade UTUC appeared to show tumor invasion into muscle or deeper. Conclusions The grade of UTUC on ureteroscopic biopsy could provide accurate diagnostic information on the final pathology of nephroureterectomy specimens. PMID:24917735

  11. Best laser for prostatectomy in the year 2013.

    PubMed

    Maheshwari, Pankaj N; Joshi, Nitin; Maheshwari, Reeta P

    2013-07-01

    Lasers have come a long way in the management of benign prostatic hyperplasia. Over last nearly two decades, various different lasers have been utilized for prostatectomy. Neodymium: yttrium-aluminum-garnet laser that started this journey, is no longer used for prostatectomy. Holmium laser can achieve transurethral enucleation of the prostatic adenoma producing a fossa that can be compared with the fossa after Freyer's prostatectomy. Green light laser has a short learning curve, is nearly blood-less with good immediate results. Thulium laser is a faster cutting laser while diode laser is a portable laser device. Often laser prostatectomy is considered as a replacement for the standard transurethral resection of prostate (TURP). To be comparable, laser should reduce or avoid the immediate and long-term complications of TURP, especially bleeding and need for blood transfusion. It should also be safe in the ever increasing patient population on antiplatelet and anticoagulant drugs. We need to take stock of the situation and identify, which among the present day lasers has stood the test of time. A review of the literature was performed to see if any of these lasers could be called the "best laser for prostatectomy in 2013."

  12. Best laser for prostatectomy in the year 2013

    PubMed Central

    Maheshwari, Pankaj N; Joshi, Nitin; Maheshwari, Reeta P

    2013-01-01

    Lasers have come a long way in the management of benign prostatic hyperplasia. Over last nearly two decades, various different lasers have been utilized for prostatectomy. Neodymium: yttrium-aluminum-garnet laser that started this journey, is no longer used for prostatectomy. Holmium laser can achieve transurethral enucleation of the prostatic adenoma producing a fossa that can be compared with the fossa after Freyer's prostatectomy. Green light laser has a short learning curve, is nearly blood-less with good immediate results. Thulium laser is a faster cutting laser while diode laser is a portable laser device. Often laser prostatectomy is considered as a replacement for the standard transurethral resection of prostate (TURP). To be comparable, laser should reduce or avoid the immediate and long-term complications of TURP, especially bleeding and need for blood transfusion. It should also be safe in the ever increasing patient population on antiplatelet and anticoagulant drugs. We need to take stock of the situation and identify, which among the present day lasers has stood the test of time. A review of the literature was performed to see if any of these lasers could be called the “best laser for prostatectomy in 2013.” PMID:24082446

  13. In-band-pumped Ho:KLu(WO4)2 microchip laser with 84% slope efficiency.

    PubMed

    Loiko, Pavel; Serres, Josep Maria; Mateos, Xavier; Yumashev, Konstantin; Kuleshov, Nikolai; Petrov, Valentin; Griebner, Uwe; Aguiló, Magdalena; Díaz, Francesc

    2015-02-01

    We report on a continuous-wave Ho:KLu(WO4)2 (KLuW) microchip laser with a record slope efficiency of 84%, the highest value among the holmium inband-pumped lasers, delivering 201 mW output power at 2105 nm. The Ho laser operating at room temperature on the (5)I8→(5)I7 transition is in-band-pumped by a diode-pumped Tm:KLuW microchip laser at 1946 nm. Ho:KLuW laser operation at 2061 and 2079 nm is also demonstrated with a maximum slope efficiency of 79%. The microchip laser generates an almost diffraction-limited output beam with a Gaussian profile and a M2<1.1. The laser performance of the Ng-cut Ho:KLuW crystal is very similar for pump light polarizations ‖Nm and Np. The positive thermal lens plays a key role in the laser mode stabilization and proper mode-matching. The latter, together with the low quantum defect under in-band-pumping (∼0.08), is responsible for the extraordinary high slope efficiency.

  14. Further characterization of photothermal breakdown products of uric acid stones following holmium:YAG laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Glickman, Randolph D.; Weintraub, Susan T.; Kumar, Neeru; Corbin, Nicole S.; Lesani, Omid; Teichman, Joel M. H.

    2000-06-01

    Previously we found that Ho:YAG laser (2120 nm) lithotripsy of uric acid stones produced cyanide, a known thermal breakdown product of uric acid. We now report that alloxan, another thermal breakdown product, is also likely produced. Uric acid stones (approximately 98% pure) of human origin were placed in distilled water and subjected to one of the following experimental treatments: unexposed control, exposed to Ho:YAG laser, Nd:YAG laser, or mechanically crushed. Samples were then processed for HPLC analysis with UV detection. Peaks were identified by comparison to authentic standards. All samples contained uric acid, with retention time (RT) about 6 min. All of the laser-exposed samples contained a peak that eluted at 2.5 min, identical to the RT of authentic alloxan. Ho:YAG laser irradiation, however, produced a larger presumed alloxan peak than did the Nd:YAG laser. The peak at 2.5 min, as well as unidentified later-eluting peaks, were present in the laser-exposed, but not the unexposed or mechanically crushed, samples. These results confirm the thermal nature of lithotripsy performed with long-pulse IR lasers.

  15. Watt-level dysprosium fiber laser at 315 μm with 73% slope efficiency

    NASA Astrophysics Data System (ADS)

    Woodward, R. I.; Majewski, M. R.; Bharathan, G.; Hudson, D. D.; Fuerbach, A.; Jackson, S. D.

    2018-04-01

    Rare-earth-doped fiber lasers are emerging as promising high-power mid-infrared sources for the 2.6-3.0 {\\mu}m and 3.3-3.8 {\\mu}m regions based on erbium and holmium ions. The intermediate wavelength range, however, remains vastly underserved, despite prospects for important manufacturing and defense applications. Here, we demonstrate the potential of dysprosium-doped fiber to solve this problem, with a simple in-band pumped grating-stabilized linear cavity generating up to 1.06 W at 3.15 {\\mu}m. A slope efficiency of 73% with respect to launched power (77% relative to absorbed power) is achieved: the highest value for any mid-infrared fiber laser to date, to the best of our knowledge. Opportunities for further power and efficiency scaling are also discussed.

  16. After urgent drainage of an obstructed kidney by internal ureteric stenting; is ureteroscopic stone extraction always needed?

    PubMed Central

    Taha, Diaa-Eldin; Elshal, Ahmed M.; Zahran, Mohamed H.; Harraz, Ahmed M.; El-Nahas, Ahmed R.; Shokeir, Ahmed A.

    2015-01-01

    Objectives To assess the probability of spontaneous stone passage and its predictors after drainage of obstructed kidney by JJ stent, as insertion of an internal ureteric stent is often used for renal drainage in cases of calcular ureteric obstruction. Patients and methods Between January 2011 and June 2013, patients for whom emergent drainage by ureteric stents were identified. The patients’ demographics, presentation, and stone characteristics were reviewed. The primary endpoint for this study was stone-free status at the time of stent removal, where all patients underwent non-contrast spiral computed tomography (NCCT) before stent removal. Ureteroscopic stone extraction was performed for CT detectable ureteric stones at the time of stent removal. Potential factors affecting the need for ureteroscopic stone extraction at the time of stent removal were assessed using univariate and multivariate statistical analyses. Results Emergent ureteric stents were undertaken in 196 patients (112 males, 84 females) with a mean (SD) age of 53.7 (16.2) years, for renal obstruction drainage. At the time of stent removal, 83 patients (42.3%) were stone free; with the remaining 113 patients (57.7%) undergoing ureteroscopic stone extraction. On multivariate analysis, stone width [odds ratio (OR) 15.849, 95% confidence interval (CI) 2.83; P = 0.002) and radio-opaque stones (OR 12.035, 95% CI 4.65; P < 0.001) were independent predictors of the need for ureteroscopic stone extraction at the time of stent removal. Conclusion Spontaneous ureteric stone passage is possible after emergent drainage of an obstructed kidney by ureteric stenting. Stone opacity, larger stone width, and positive preoperative urine culture are associated with a greater probability of requiring ureteroscopic stone extraction after emergent drainage by ureteric stenting. PMID:26609444

  17. The Advantage of a Ureteroscopic Navigation System with Magnetic Tracking in Comparison with Simulated Fluoroscopy in a Phantom Study.

    PubMed

    Yoshida, Kenji; Yokomizo, Akira; Matsuda, Tadashi; Hamasaki, Tsutomu; Kondo, Yukihiro; Yamaguchi, Kunihisa; Kanayama, Hiro-Omi; Wakumoto, Yoshiaki; Horie, Shigeo; Naito, Seiji

    2015-09-01

    To assess whether our ureteroscopic real-time navigation system has the possibility to reduce radiation exposure and improve performance of ureteroscopic maneuvers in surgeons of various ages and experience levels. Our novel ureteroscopic navigation system used a magnetic tracking device to detect the position of the ureteroscope and display it on a three-dimensional image. We recruited 31 urologists from five institutions to perform two tasks. Task 1 consisted of finding three internal markings on the phantom calices. Task 2 consisted of identifying all calices by ureteroscopy. In both tasks, participants performed with simulated fluoroscopy first, followed by our navigation system. Accuracy rates (AR) for identification, required time (T) for completing the task, migration length (ML), and time exposed to simulated fluoroscopy were recorded. The AR, T, and ML for both tasks were significantly better with the navigation system than without it (Task 1 with simulated fluoroscopy vs with navigation: AR 87.1 % vs 98.9%, P=0.003; T 355 s vs 191 s, P<0.0001; ML 4627 mm vs 2701 mm, P<0.0001. Task 2: AR 88.2% vs 96.7%, P=0.011; T 394 s vs 333 s, P=0.027; ML 5966 mm vs 5299 mm, P=0.0006). In both tasks, the participants used the simulated fluoroscopy about 20% of the total task time. Our navigation system, while still under development, could help surgeons of all levels to achieve better performances for ureteroscopic maneuvers compared with using fluoroscopic guidance. It also has the potential to reduce radiation exposure during fluoroscopy.

  18. Application of ureterorenoscope and flexible ureterorenoscope lithotripsy in removing calculus from extracorporeal living donor renal graft: a single-center experience.

    PubMed

    Lin, Chun-Hua; Zhang, Zuo-Fu; Wang, Jiahui; Yu, Lu-Xin; Wang, Wen-Ting; Shi, Lei; Lin, Xiang-Nan

    2017-11-01

    Here, we reported our clinical application of ureterorenoscope (URS) and flexible URS lithotripsy in stone removal on 10 cases of excised living donor kidney graft. After the extraction of donor kidney by retroperitoneal laparoscopy, the donor graft was perfused with 4 °C HCA solution. Calculus between 2-4 mm were removed intact with lithotomy forceps under direct vision of URS. Larger calculi of >4 mm were fractured with flexible URS combining holmium laser lithotripsy. Fragments of the calculus were extracted with basket extractor and lithotomy forceps. All operations were successful. The operation time was 14-31 min (average 21.2 ± 6.3 min). The kidneys were then transplanted to the recipients using routine procedure. The transplanted kidneys functioned well after transplantation. Gross hematuria resolved 1-4 d after operation (average 2.6 ± 0.9 d). The transplanted kidneys functioned well without early complications such as functional recovery delay and acute graft rejection. The donors and recipients were followed for 12 months. The size of the transplanted kidneys was normal and new stones or urinary obstruction was not seen upon urinary color Doppler ultrasound examination. In conclusion, we believe it is feasible, safe and effective to use URS or flexible URS combining holmium laser lithotripsy on extracorporeal living donor kidney.

  19. Lasers in clinical urology: state of the art and new horizons.

    PubMed

    Marks, Andrew J; Teichman, Joel M H

    2007-06-01

    We present an overview of current and emerging lasers for Urology. We begin with an overview of the Holmium:YAG laser. The Ho:YAG laser is the gold standard lithotripsy modality for endoscopic lithotripsy, and compares favorably to standard electrocautery transurethral resection of the prostate for benign prostatic hyperplasia (BPH). Available laser technologies currently being studied include the frequency doubled double-pulse Nd:Yag (FREDDY) and high-powered potassium-titanyl-phosphate (KTP) lasers. The FREDDY laser presents an affordable and safe option for intracorporeal lithotripsy, but it does not fragment all stone compositions, and does not have soft tissue applications. The high power KTP laser shows promise in the ablative treatment of BPH. Initial experiments with the Erbium:YAG laser show it has improved efficiency of lithotripsy and more precise ablative and incisional properties compared to Ho:YAG, but the lack of adequate optical fibers limits its use in Urology. Thulium:YAG fiber lasers have also demonstrated tissue ablative and incision properties comparable to Ho:YAG. Lastly, compact size, portability, and low maintenance schedules of fiber lasers may allow them to shape the way lasers are used by urologists in the future.

  20. Facial and meridional isomers of holmium-nitrate N-tert-butylacetamide complexes

    NASA Astrophysics Data System (ADS)

    Chang, Ye-Di; Xue, Jun-Hui; Kang, Xiao-Yan; Yang, Li-Min; Li, Wei-Hong; Xu, Yi-Zhuang; Zhao, Guo-Zhong; Zhang, Gao-Hui; Liu, Ke-Xin; Chen, Jia-Er; Wu, Jin-Guang

    2018-06-01

    Two Ho(C6H13NO)3(NO3)3 complexes formed by holmium nitrate and N-tert-butylacetamide (NtBA) (Ho-NtBA(I) in a Cc space group, and Ho-NtBA(II) in a P21/c space group) are reported here to investigate the coordination of lanthanide ions with amide groups. Using X-ray single crystal diffraction, FTIR, Raman, FIR and THz methods the structures of the two complexes were identified, in which Ho3+ is 9-coordinated to three carbonyl oxygen atoms provided by three NtBA ligands and three bidentate nitrate ions to form the "facial" and "meridional" isomers. Their FTIR and Raman spectra indicate the formation of two holmium complexes, the variations of NtBA after holmium coordination and the spectra are similar for the isomers in some extent. Their FIR and THz spectroscopic results show the coordination of holmium ions and THz maybe more sensitive to isomers. The results demonstrate the coordination behaviors of holmium ions and NtBA ligand.

  1. Acute results, complications, and effect of lesion characteristics on outcome with the solid-state, pulsed-wave, mid-infrared laser angioplasty system: final multicenter registry report. Holmium:YAG Laser Multicenter Investigators.

    PubMed

    Topaz, O; McIvor, M; Stone, G W; Krucoff, M W; Perin, E C; Foschi, A E; Sutton, J; Nair, R; deMarchena, E

    1998-01-01

    The solid-state, mid-infrared holmium:YAG laser (2.1 microm wavelength) is a relatively new percutaneous device that has recently been evaluated in a multicenter study. Because of its unique wavelength and photoacoustic effects on atherosclerotic plaques, this laser may be useful in treatment of symptomatic patients with coronary artery disease. This study sought to evaluate the safety and efficacy of mid-infrared laser angioplasty in the treatment of coronary artery lesions. Laser angioplasty was performed on 2,038 atherosclerotic lesions in 1,862 consecutive patients with a mean age of 61 +/- 11 years. Clinical indications included unstable angina (69%), stable angina (20%), acute infarction (6%), and positive exercise test (5%). Complex lesion morphology included eccentricity (62%), thrombus (30%), total occlusion (27%), long lesions (14%), and saphenous vein grafts (11%). This laser catheter alone successfully reduced stenosis (>20%) in 87% of lesions. With adjunct balloon angioplasty, 93% procedural success was achieved. The presence of thrombus within the target lesion was a predictor of procedural success (OR = 2.0 [95% confidence interval 2.0, 4.0], P = .04). Bifurcation lesions (OR = 0.5 [95% confidence interval 0.2, 1.0], P = .05) and severe tortuosity of the treated vessel (OR = 0.4 [95% confidence interval 0.2, 0.9], P = .02) were identified as significant predictors of decreased laser success. Calcium within the lesion was associated with reduced procedural success (OR = 0.57 [95% confidence interval 0.34, 0.97], P = .03), and calcified lesions required significantly more energy pulses than noncalcified lesions (119 +/- 91 pulses vs. 101 +/- 86 pulses, respectively, P = .0002). Complications included in-hospital bypass surgery 2.5%, Q-wave myocardial infarction 1.2%, and death 0.8%. Perforation occurred in 2.2% of patients; major dissection in 5.8% of patients, and spasm in 12% of patients. No predictor of major complications was identified. Six-month angiographic restenosis was documented in 54% of patients, and clinical restenosis occurred in 34% of patients. Mid-infrared laser has a safety profile similar to that of other debulking devices. This laser may be useful in select patients presenting with acute ischemic syndromes associated with intracoronary thrombus; however, like other coronary lasers, it is limited by the need for adjunctive balloon angioplasty and/or stenting to achieve adequate final luminal diameter. No beneficial effects on reducing 6-month restenosis rates were observed.

  2. Update on the use of diode laser in the management of benign prostate obstruction in 2014.

    PubMed

    Lusuardi, Lukas; Mitterberger, Michael; Hruby, Stephan; Kunit, Thomas; Kloss, Birgit; Engelhardt, Paul F; Sieberer, Manuela; Janetschek, Günter

    2015-04-01

    To determine the status quo in respect of various diode lasers and present the techniques in use, their results and complications. We assess how these compare with transurethral resection of the prostate and other types of laser in randomized controlled trials (RCTs). When adequate RCTs were not available, case studies and reports were evaluated. Laser for the treatment of benign prostatic hyperplasia (BPH) has aroused the interest and curiosity of urologists as well as patients. The patient associates the term laser with a successful and modern procedure. The journey that started with coagulative necrosis of prostatic adenoma based on neodymium: yttrium-aluminum-garnet (Nd:YAG) laser has culminated in endoscopic "enucleation" with holmium laser. Diode laser is being used in urology for about 10 years now. Various techniques have been employed to relieve bladder outlet obstruction due to BPH. The diode laser scenario is marked by a diversity of surgical techniques and wavelengths. We summarize the current published literature in respect of functional results and complications. More randomized controlled studies are needed to determine the position and the ideal technique of diode laser treatment for BPH.

  3. Holmium:YAG Laser Ablation for the Management of Lower Urinary Tract Foreign Bodies Following Incontinence Surgery: A Case Series and Systematic Review.

    PubMed

    Chan, Garson; Mamut, Adiel; Martin, Paul; Welk, Blayne

    2016-11-01

    The objective of this study was to determine the outcomes associated with the endoscopic removal of foreign bodies (such as mesh or permanent suture) in the lower urinary tract after female stress incontinence surgery with the Holmium:YAG (Ho:YAG) laser, and to systematically review the literature on this topic. A retrospective chart review of 18 consecutive women found to have mesh or suture exposure was performed. All patients underwent Ho:YAG laser ablation. A systematic review was performed to identify literature addressing the endoscopic management of mesh/suture exposure after stress incontinence surgery. Between November 2011 and February 2016, 18 women underwent Ho:YAG laser ablation of exposed mesh or suture. Presenting symptoms included lower urinary tract symptoms, pelvic pain, incontinence, or recurrent urinary tract infections. Thirteen women had a previous synthetic midurethral sling and five had a prior retropubic suspension. The median age was 58 years (interquartile range [IQR] 50-60) and median follow-up was 2 years (IQR 1-2). Four patients (22%) had residual mesh after the first procedure, requiring a repeat endoscopic procedure. Only one patient had a small amount of asymptomatic residual mesh on cystoscopy after the final procedure. Only minor postoperative complications were observed. Eight patients had stress incontinence and four underwent operative treatment for this. In our systematic review, we identified 16 case series, which described a total of 158 patients. Women most commonly presented with voiding symptoms or incontinence. Based on the synthesis of these data, repeat procedures were necessary in 16% and vesicovaginal fistula occurred in 2%. Recurrent/persistent stress incontinence was present in 20%, and of these patients, 3/4 underwent a new stress incontinence procedure. Both our case series and the systematic review of the literature demonstrated that endoscopic treatment of lower urinary tract foreign bodies after stress incontinence surgery has good success rates and minimal morbidity.

  4. Effect of Young's modulus on bubble formation and pressure waves during pulsed holmium ablation of tissue phantoms

    NASA Astrophysics Data System (ADS)

    Jansen, E. Duco; Asshauer, Thomas; Frenz, Martin; Delacretaz, Guy P.; Motamedi, Massoud; Welch, Ashley J.

    1995-05-01

    Mechanical injury during pulsed laser ablation of tissue is caused by rapid bubble expansions and collapse or by laser-induced pressure waves. In this study the effect of material elasticity on the ablation process has been investigated. Polyacrylamide tissue phantoms with various water concentrations (75-95%) were made. The Young's moduli of the gels were determined by measuring the stress-strain relationship. An optical fiber (200 or 400 micrometers ) was translated into the clear gel and one pulse of holmium:YAG laser radiation was given. The laser was operated in either the Q-switched mode (tau) p equals 500 ns, Qp equals 14 +/- 1 mJ, 200 micrometers fiber, Ho equals 446 mJ/mm2) or the free-running mode ((tau) p equals 100 microsecond(s) , Qp equals 200 +/- 5 mJ, 400 micrometers fiber, Ho equals 1592 mJ/mm2). Bubble formation inside the gels was recorded using a fast flash photography setup while simultaneously recording pressures with a PVDP needle hydrophone (40 ns risetime) positioned in the gel, approximately 2 mm away from the fibertip. A thermo-elastic expansion wave was measured only during Q-switched pulse delivery. The amplitude of this wave (approximately equals 40 bar at 1 mm from the fiber) did not vary significantly in any of the phantoms investigated. Rapid bubble formation and collapse was observed inside the clear gels. Upon bubble collapse, a pressure transient was emitted; the amplitude of this transient depended strongly on bubble size and geometry. It was found that (1) the bubble was almost spherical for the Q-switched pulse and became more elongated for the free-running pulse, and (2) the maximum bubble size and thus the collapse amplitude decreased with an increase in Young's modulus (from 68 +/- 11 bar at 1 mm in 95% water gel to 25 +/- 10 bar at 1 mm in 75% water gel).

  5. Nurse-Initiated Telephone Follow Up after Ureteroscopic Stone Surgery.

    PubMed

    Tackitt, Helen M; Eaton, Samuel H; Lentz, Aaron C

    2016-01-01

    This article presents findings of a quality improvement (QI) project using the DMAIC (define, measure, analyze, improve, and control) model designed to decrease the rate of emergency department (ED) visits and nurse advice line calls after ureteroscopic stone surgery. Results indicated that nurse-initiated follow- up phone calls can decrease ED visits.

  6. Evaluation of Ignition and Burn Risk Associated with Contemporary Fiberoptic and Distal Sensor Endoscopic Technology.

    PubMed

    Spradling, Kyle; Uribe, Brittany; Okhunov, Zhamshid; Hofmann, Martin; Del Junco, Michael; Hwang, Christina; Gruber, Caden; Youssef, Ramy F; Landman, Jaime

    2015-09-01

    To evaluate the ignition and burn risk associated with contemporary fiberoptic and distal sensor endoscopic technologies. We used new and used SCB Xenon 300 light sources to illuminate a 4.8 mm fiberoptic cable, 10 mm laparoscope, 5 mm laparoscope, rigid cystoscope, semirigid ureteroscope, flexible cystoscope, flexible fiberoptic ureteroscope, distal sensor cystoscope, and a distal sensor ureteroscope (Karl Storz, Inc., Tuttlingen, Germany). We measured peak temperatures at the distal end of each device. We then evaluated each device on a flat and folded surgical drape to establish ignition risk. Finally, we evaluated the effects of all devices on human cadaver skin covered by surgical drape. Peak temperatures recorded for each device ranged from 26.9°C (flexible fiberoptic ureteroscope) to 194.5°C (fiberoptic cable). Drape ignition was noted when the fiberoptic cable was placed against a fold of drape. Contact with the fiberoptic cable, 10 mm laparoscope, 5 mm laparoscope, and distal sensor cystoscope resulted in cadaver skin damage. Cadaver skin damage occurred despite little or no visible change to the surgical drape. Rigid and flexible fiberoptic cystoscopes and flexible fiberoptic ureteroscopes had no effect on surgical drapes or cadaver skin. Fiberoptic light cables and some endoscopic devices have the potential to cause thermal injury and drape ignition. Thermal injury may occur without visible damage to drapes. Surgeons should remain vigilant regarding the risks associated with these devices and take necessary safety precautions to prevent patient injury.

  7. The mechanism of joint capsule thermal modification in an in-vitro sheep model.

    PubMed

    Hayashi, K; Peters, D M; Thabit, G; Hecht, P; Vanderby, R; Fanton, G S; Markel, M D

    2000-01-01

    The purpose of this study was to understand the mechanism responsible for joint capsule shrinkage after nonablative laser application in an in-vitro sheep model. Femoropatellar joint capsular tissue specimens harvested from 20 adult sheep were treated with one of three power settings of a holmium:yttrium-aluminum-garnet laser or served as a control. Laser treatment significantly shortened the tissue and decreased tissue stiffness in all three laser groups, whereas failure strength was not altered significantly by laser treatment. Transmission electron microscopic examination showed swollen collagen fibrils and loss of membrane integrity of fibroblasts. A thermometric study revealed nonablative laser energy caused tissue temperature to rise in the range of 64 degrees C to 100 degrees C. Electrophoresis after trypsin digestion of the tissue revealed significant loss of distinct alpha bands of Type I collagen in laser treated samples, whereas alpha bands were present in laser treated tissue without trypsin digestion. The results of this study support the concept that the primary mechanism responsible for the effect of nonablative laser energy is thermal denaturation of collagen in joint capsular tissue associated with unwinding of the triple helical structure of the collagen molecule.

  8. Magneto-optical study of holmium iron garnet Ho3Fe5O12

    NASA Astrophysics Data System (ADS)

    Kalashnikova, A. M.; Pavlov, V. V.; Kimel, A. V.; Kirilyuk, A.; Rasing, Th.; Pisarev, R. V.

    2012-09-01

    Bulk holmium iron garnet Ho3Fe5O12 is a cubic ferrimagnet with Curie temperature TC = 567 K and magnetization compensation point in the range 130-140 K. The magneto-optical data are presented for a holmium iron garnet Ho3Fe5O12 film, ˜10 μm thick, epitaxially grown on a (111)-type gadolinium-gallium garnet Gd3Ga5O12 substrate. A specific feature of this structure is that the parameters of the bulk material, from which the film was grown, closely match the substrate ones. The temperature and field dependences of Faraday rotation as well as the temperature dependence of the domain structure in zero field were investigated. The compensation point of the structure was found to be Tcomp = 127 K. It was shown that the temperature dependence of the characteristic size of domain structure diverges at this point. Based on the obtained results we established that the magnetic anisotropy of the material is determined by both uniaxial and cubic contributions, each characterized by different temperature dependence. A complex shape of hysteresis loops and sharp changes of the domain pattern with temperature indicate the presence of collinear-noncollinear phase transitions. Study of the optical second harmonic generation was carried out using 100 fs laser pulses with central photon energy E = 1.55 eV. The electric dipole contribution (both crystallographic and magnetic) to the second harmonic generation was observed with high reliability despite a small mismatch of the film and substrate parameters.

  9. Cutting and skin-ablative properties of pulsed mid-infrared laser surgery.

    PubMed

    Kaufmann, R; Hartmann, A; Hibst, R

    1994-02-01

    Pulsed mid-infrared lasers allow a precise removal of soft tissues with only minimal thermal damage. To study the potential dermatosurgical usefulness of currently available systems at different wavelengths (2010-nm Thulium:YAG laser, 2100-nm Holmium:YAG laser, 2790-nm Erbium:YSGG laser, and 2940-nm Erbium:YAG laser) in vivo on pig skin. Immediate effects and wound healing of superficial laser-abrasions and incisions were compared with those of identical control lesions produced by dermabrasion, scalpel incisions, or laser surgery performed by a 1060-nm Nd:YAG and a 1060-nm CO2 laser (continuous and superpulsed mode). Best efficiency and least thermal injury was found for the pulsed Erbium:YAG laser, leading to ablative and incisional lesions comparable to those obtained by dermabrasion or superficial scalpel incisions, respectively. In contrast to other mid-infrared lasers tested, the 2940-nm Erbium:YAG laser thus provides a potential instrument for future applications in skin surgery, especially when aiming at a careful ablative removal of delicate superficial lesions with maximum sparing of adjacent tissue structures. However, in the purely incisional application mode pulsed mid-infrared lasers, though of potential usefulness in microsurgical indications (eg, surgery of the cornea), do not offer a suggestive alternative to simple scalpel surgery of the skin.

  10. Biokinetics of yttrium and comparison with its geochemical twin holmium

    DOE PAGES

    Leggett, Rich

    2017-06-01

    The transition metal yttrium (Y, atomic number 39) is chemically similar to elements in the lanthanide family (atomic numbers 57-71, lanthanum through lutetium) and is always present with the lanthanides in rare earth ores. Yttrium and the lanthanide holmium are particularly close chemical and physical analogues and are referred to as geochemical twins because they typically show little fractionation in geological material. Extensive measurements on rocks, soils, and meteorites indicate that the Y/Ho mass concentration ratio rarely falls far from the “chondritic” or “solar system” ratio of ~26. Our paper presents a new biokinetic model for yttrium in adult humansmore » and examines whether yttrium and holmium may be biological as well as geochemical twins. Collected data on yttrium and holmium in plants and human tissues do not allow precise derivations of Y/Ho concentration ratios but with occasional exceptions yield ratios that are reasonably consistent with chondritic values. Predictions of the time-dependent behavior of yttrium in adult humans based on the yttrium model presented here closely approximate predictions of the behavior of holmium based on a previously developed model for holmium. We know that yttrium and holmium are close biological analogues, but the available comparative data are too limited and imprecise to reveal whether there are any significant differences in their biological behavior.« less

  11. [Giant prostatic calculus with neurogenic bladder disease and prostate diverticulum: a case report and review of the literature].

    PubMed

    Li, Xiao-Shi; Quan, Chang-Yi; Li, Gang; Cai, Qi-Liang; Hu, Bin; Wang, Jiu-Wei; Niu, Yuan-Jie

    2013-02-01

    To study the etiology, clinical manifestation, diagnosis and treatment of giant prostatic calculus with neurogenic bladder disease and prostate diverticulum. We retrospectively analyzed the clinical data of a case of giant prostatic calculus with neurogenic bladder disease and prostate diverticulum and reviewed the relevant literature. The patient was a 37-year-old man, with urinary incontinence for 22 years and intermittent dysuria with frequent micturition for 9 years, aggravated in the past 3 months. He had received surgery for spina bifida and giant vesico-prostatic calculus. The results of preoperative routine urinary examination were as follows: WBC 17 -20/HPF, RBC 12 - 15/HPF. KUB, IVU and pelvic CT revealed spina bifida occulta, neurogenic bladder and giant prostatic calculus. The patient underwent TURP and transurethral lithotripsy with holmium-YAG laser. The prostatic calculus was carbonate apatite in composition. Urinary dynamic images at 2 weeks after surgery exhibited significant improvement in the highest urine flow rate and residual urine volume. Seventeen months of postoperative follow-up showed dramatically improved urinary incontinence and thicker urine stream. Prostate diverticulum with prostatic giant calculus is very rare, and neurogenic bladder may play a role in its etiology. Cystoscopy is an accurate screening method for its diagnosis. For the young patients and those who wish to retain sexual function, TURP combined with holmium laser lithotripsy can be employed, and intraoperative rectal examination should be taken to ensure complete removal of calculi.

  12. Predictors of urgency improvement after Holmium laser enucleation of the prostate in men with benign prostatic hyperplasia.

    PubMed

    Hur, Won Sok; Kim, Joon Chul; Kim, Hyo Sin; Koh, Jun Sung; Kim, Sang Hoon; Kim, Hyun Woo; Cho, Su Yeon; Cho, Kang Jun

    2016-11-01

    To investigate the change in urinary urgency and predictors of urgency improvement after holmium laser enucleation of the prostate (HoLEP) in men with benign prostatic hyperplasia (BPH). We retrospectively analyzed the medical records of patients who were treated with HoLEP for BPH and had preoperative urgency measuring ≥3 on a 5-point urinary sensation scale. Those with prostate cancer diagnosed prior to or after HoLEP, a history of other prostatic and/or urethral surgery, moderate to severe postoperative complications, and neurogenic causes were excluded. Patients who had improved urgency with antimuscarinic medication after HoLEP were excluded. We divided the patients into 2 groups based on urgency symptoms 3 months after HoLEP: improved and unimproved urgency. Improved urgency was defined as a reduction of 2 or more points on the 5-point urinary sensation scale. Preoperative clinical and urodynamic factors as well as perioperative factors were compared between groups. In total, 139 patients were included in this study. Voiding parameters in all patients improved significantly after HoLEP. Seventy-one patients (51.1%) had improved urgency, while 68 (48.9%) did not show any improvement. A history of acute urinary retention (AUR) and postvoid residual were associated with postoperative urgency improvement in univariate analysis. In multivariate analysis, a history of AUR was an independent factor affecting urgency improvement. A preoperative history of AUR could influence the change in urgency after HoLEP surgery in patients with BPH.

  13. Surgical Management of Stones: New Technology

    PubMed Central

    Matlaga, Brian R.; Lingeman, James E.

    2011-01-01

    In recent years, the surgical treatment of kidney stone disease has undergone tremendous advances, many of which were possible only as a result of improvements in surgical technology. Rigid intracorporeal lithotrites, the mainstay of percutaneous nephrolithotomy, are now available as combination ultrasonic and ballistic devices. These combination devices have been reported to clear a stone burden with much greater efficiency than devices that operate by either ultrasonic or ballistic energy alone. The laser is the most commonly used flexible lithotrite; advances in laser lithotripsy have led to improvements in the currently utilized Holmium laser platform, as well as the development of novel laser platforms such as Thulium and Erbium devices. Our understanding of shock wave lithotripsy (SWL)has been improved over recent years as a consequence of basic science investigations. It is now recognized that there are certain maneuvers with SWL that the treating physician can do that will increase the likelihood of a successful outcome while minimizing the likelihood of adverse treatment-related events. PMID:19095207

  14. [Combination of the ureteral dilation catheter and balloon catheter under the ureteroscope in the treatment of male urethral stricture].

    PubMed

    Zhou, Yi; Li, Gong-hui; Yan, Jia-jun; Shen, Cong; Tang, Gui-hang; Xu, Gang

    2016-01-01

    To investigate the clinical application of the ureteral dilation catheter combined with the balloon catheter under the ureteroscope in the treatment of urethral stricture in men. Under the ureteroscope, 45 male patients with urethral stricture received placement of a zebra guide wire through the strictured urethra into the bladder and then a ureteral dilation catheter along the guide wire, followed by dilation of the urethra from F8 initially to F14 and F16. Again, the ureteroscope was used to determine the length of the strictured urethra, its distance to the external urethral orifice, and whether it was normally located. An F24 balloon catheter and then a metal urethral calibrator was used for the dilation of the strictured urethra. After removal of the F18-F22 urethral catheter at 8 weeks, the urinary flow rate was measured immediately and again at 3 months. All the operations were successfully performed without serious complications. The maximum urinary flow rate was (13.3-29.9) ml/s (mean [17.7 ± 3.2] ml/s) at the removal of the catheter and (15.2-30.8) ml/s (mean [19.8 ± 3.9] ml/s) at 3 months after it. Smooth urination was found in all the patients during the 6-24 months follow-up. The application of the ureteral dilation catheter combined with, the balloon catheter under the ureteroscope is a good option for the treatment of male urethral stricture for its advantages of uncomplicatedness, safety, effectiveness, few complications, less pain, high success rate, and repeatable operation.

  15. Clinical factors associated with postoperative hydronephrosis after ureteroscopic lithotripsy.

    PubMed

    Kim, Sun Woo; Ahn, Ji Hoon; Yim, Sang Un; Cho, Yang Hyun; Shin, Bo Sung; Chung, Ho Seok; Hwang, Eu Chang; Yu, Ho Song; Oh, Kyung Jin; Kim, Sun-Ouck; Jung, Seung Il; Kang, Taek Won; Kwon, Dong Deuk; Park, Kwangsung

    2016-09-01

    This study aimed to determine the predictors of ipsilateral hydronephrosis after ureteroscopic lithotripsy for ureteral calculi. From January 2010 to December 2014, a total of 204 patients with ureteral calculi who underwent ureteroscopic lithotripsy were reviewed. Patients with lack of clinical data, presence of ureteral rupture, and who underwent simultaneous percutaneous nephrolithotomy (PNL) were excluded. Postoperative hydronephrosis was determined via computed tomographic scan or renal ultrasonography, at 6 months after ureteroscopic lithotripsy. Multivariable analysis was performed to determine clinical factors associated with ipsilateral hydronephrosis. A total of 137 patients were enrolled in this study. The mean age of the patients was 58.8±14.2 years and the mean stone size was 10.0±4.6 mm. The stone-free rate was 85.4%. Overall, 44 of the 137 patients (32.1%) had postoperative hydronephrosis. Significant differences between the hydronephrosis and nonhydronephrosis groups were noted in terms of stone location, preoperative hydronephrosis, impacted stone, operation time, and ureteral stent duration (all, p<0.05). On multivariable analysis, increasing preoperative diameter of the hydronephrotic kidney (adjusted odds ratio [OR], 1.21; 95% confidence interval [CI], 1.12-1.31; p=0.001) and impacted stone (adjusted OR, 3.01; 95% CI, 1.15-7.61; p=0.031) independently predicted the occurrence of postoperative hydronpehrosis. Large preoperative diameter of the hydronephrotic kidney and presence of impacted stones were associated with hydronephrosis after ureteroscopic stone removal. Therefore, patients with these predictive factors undergo more intensive imaging follow-up in order to prevent renal deterioration due to postoperative hydronephrosis.

  16. Clinical factors associated with postoperative hydronephrosis after ureteroscopic lithotripsy

    PubMed Central

    Kim, Sun Woo; Ahn, Ji Hoon; Yim, Sang Un; Cho, Yang Hyun; Shin, Bo Sung; Chung, Ho Seok; Yu, Ho Song; Oh, Kyung Jin; Kim, Sun-Ouck; Jung, Seung Il; Kang, Taek Won; Kwon, Dong Deuk; Park, Kwangsung

    2016-01-01

    Purpose This study aimed to determine the predictors of ipsilateral hydronephrosis after ureteroscopic lithotripsy for ureteral calculi. Materials and Methods From January 2010 to December 2014, a total of 204 patients with ureteral calculi who underwent ureteroscopic lithotripsy were reviewed. Patients with lack of clinical data, presence of ureteral rupture, and who underwent simultaneous percutaneous nephrolithotomy (PNL) were excluded. Postoperative hydronephrosis was determined via computed tomographic scan or renal ultrasonography, at 6 months after ureteroscopic lithotripsy. Multivariable analysis was performed to determine clinical factors associated with ipsilateral hydronephrosis. Results A total of 137 patients were enrolled in this study. The mean age of the patients was 58.8±14.2 years and the mean stone size was 10.0±4.6 mm. The stone-free rate was 85.4%. Overall, 44 of the 137 patients (32.1%) had postoperative hydronephrosis. Significant differences between the hydronephrosis and nonhydronephrosis groups were noted in terms of stone location, preoperative hydronephrosis, impacted stone, operation time, and ureteral stent duration (all, p<0.05). On multivariable analysis, increasing preoperative diameter of the hydronephrotic kidney (adjusted odds ratio [OR], 1.21; 95% confidence interval [CI], 1.12–1.31; p=0.001) and impacted stone (adjusted OR, 3.01; 95% CI, 1.15–7.61; p=0.031) independently predicted the occurrence of postoperative hydronpehrosis. Conclusions Large preoperative diameter of the hydronephrotic kidney and presence of impacted stones were associated with hydronephrosis after ureteroscopic stone removal. Therefore, patients with these predictive factors undergo more intensive imaging follow-up in order to prevent renal deterioration due to postoperative hydronephrosis. PMID:27617316

  17. Is there a role for small-diameter ureteral access sheaths? Impact on irrigant flow and intrapelvic pressures.

    PubMed

    Monga, Manoj; Bodie, Joshua; Ercole, Barbara

    2004-09-01

    To evaluate irrigant flows and intrapelvic pressures with small-diameter access sheaths. Ureteral access sheaths improve irrigant flow and decrease intrarenal pelvic pressures during flexible ureteroscopy. However, no comparisons of individual sheaths have been conducted. Previous studies have demonstrated more favorable results with the 12F sheath than with the 10F sheath. Ureteral access sheaths were tested ex vivo in porcine kidneys. An 18F angiocatheter was placed in the renal pelvis and connected to a Hewlett Packard Gauss Pressure transducer. Irrigant was maintained at 100 mm Hg pressure. Irrigant flow and intrapelvic pressures were measured with three flexible ureteroscopes at baseline and using each of four 10F sheaths, with the sheaths positioned in the middle ureter and the ureteroscopes positioned in the renal pelvis. The pressure at which irrigant efflux through the sheath occurred and the rate of irrigant efflux through the access sheath were measured. Intrapelvic pressures measured greater than 40 mm Hg, and irrigant flows remained at less than 15 mL/min when the Olympus URF-P3 and Storz 11274AAU flexible ureteroscopes were tested with all four sheaths. The intrapelvic pressures, irrigant inflow, and irrigant efflux with the Wolf 7325.172 (7.5F) flexible ureteroscope were optimized in combination with the Cook Peelaway 10F and Applied Access 10F sheaths. Small ureteral access sheaths should be used only with the Wolf 7325.172 flexible ureteroscope. The Cook Peelaway (10F) and Applied Access (10F) sheaths offered the greatest increase in irrigant flow and decrease in intrapelvic pressures.

  18. Ureteroscopy for the management of stone disease.

    PubMed

    Eisner, Brian H; Kurtz, Michael P; Dretler, Stephen P

    2010-01-01

    Ureteroscopy is the first-line treatment for urinary stone disease at many institutions. Techniques and indications continue to evolve. This Review covers the most current trends, controversies, and issues in ureteroscopic stone management. We present a summary of the most recent evidence regarding ureteroscopic treatment of ureteral and renal stones, current standard indications, adjunct devices and instruments used during ureteroscopy, and future directions.

  19. Endoscopic Stone Measurement During Ureteroscopy.

    PubMed

    Ludwig, Wesley W; Lim, Sunghwan; Stoianovici, Dan; Matlaga, Brian R

    2018-01-01

    Currently, stone size cannot be accurately measured while performing flexible ureteroscopy (URS). We developed novel software for ureteroscopic, stone size measurement, and then evaluated its performance. A novel application capable of measuring stone fragment size, based on the known distance of the basket tip in the ureteroscope's visual field, was designed and calibrated in a laboratory setting. Complete URS procedures were recorded and 30 stone fragments were extracted and measured using digital calipers. The novel software program was applied to the recorded URS footage to obtain ureteroscope-derived stone size measurements. These ureteroscope-derived measurements were then compared with the actual-measured fragment size. The median longitudinal and transversal errors were 0.14 mm (95% confidence interval [CI] 0.1, 0.18) and 0.09 mm (95% CI 0.02, 0.15), respectively. The overall software accuracy and precision were 0.17 and 0.15 mm, respectively. The longitudinal and transversal measurements obtained by the software and digital calipers were highly correlated (r = 0.97 and 0.93). Neither stone size nor stone type was correlated with error measurements. This novel method and software reliably measured stone fragment size during URS. The software ultimately has the potential to make URS safer and more efficient.

  20. Development of mid-infrared solid state lasers for spaceborne lidar

    NASA Technical Reports Server (NTRS)

    Whitney, Donald A.; Kim, Kyong H.

    1989-01-01

    Laser performance of Ho(3+):Tm(3+):Cr(3+):YAG crystals was investigated under both Cr:GSAG laser and flashlamp pumping. A flashlamp pumped Cr:GSAG laser was built to simulate high power quasi-CW laser diode pumping of a 2.1 micrometer holmium laser. The 2.1 micrometer output laser energy exceeded more than 14 mJ, the highest value reported to date under laser pumping near 785 nm. This was obtained in a pulse length of nearly 650 microsec from a 3 x 3 mm Ho:Tm:Cr:YAG rod by using the flashlamp-pumped Cr:CSAG laser as a pumping source at the diode laser wavelength, 785 micrometers. In addition, Ho:Tm:Cr:YAG crystals with various Tm(3+) concentrations were evaluated for flashlamp-pumped normal mode and Q-switched 2.1 micrometer laser operations under a wide variety of experimental conditions in order to understand internal dynamic processes among the ions and to determine an optimum lasing condition. An increase of the laser slope efficiency was observed with the increase of the Tm(3+) concentration from 2.5 to 4.5 atomic percent. The thermal dependence of the laser performance was also investigated. Q-switched laser output energies corresponding to nearly 100 percent of the normal-mode laser energies were obtained in a strong single spike of 200 ns pulse length by optimizing the opening time of a lithium niobate Q-switch.

  1. Office flexible cystoscopy.

    PubMed

    Kavoussi, L R; Clayman, R V

    1988-11-01

    Since the development of the first purpose-built flexible cystoscope in 1984, flexible cystoscopy has become an accepted diagnostic and therapeutic modality. Indeed, it is estimated that more than 10 per cent of practicing urologists are already familiar with this technology. The flexible cystoscope has markedly extended the urologist's ability to examine the bladder, and it has become a valuable adjunct to the rigid cystoscope. Although the operation of this instrument is vastly different from that of its rigid counterpart, with practice, the technique can be learned. After experience is obtained with diagnostic flexible cystoscopy, the urologist will likely prefer this new instrument for bladder inspection, as it provides for a more thorough yet less morbid and less expensive examination. In the future, the development of improved and smaller instrumentation will further extend the therapeutic indications for flexible cystoscopy. Indeed, advances in laser technology are already providing the urologist with 300- to 600-micron (0.9 to 1.8F) flexible probes capable of incision (KTP laser), fulguration (Nd:YAG laser), and stone disintegration (tunable dye laser). Lastly, the skills obtained in using the flexible cystoscope are all readily applicable to the development of dexterity with the already available flexible nephroscope and the more recently developed flexible ureteroscope.

  2. Development and characterisation of polymeric microparticle of poly(d,l-lactic acid) loaded with holmium acetylacetonate.

    PubMed

    de Azevedo, Mariangela de Burgos M; de Melo, Vitor H S; Soares, Carlos Roberto J; Miyamoto, Douglas M; Katayama, Ricardo A; Squair, Peterson L; Barros, Caio H N; Tasic, Ljubica

    2018-06-14

    Biodegradable polymers containing radioactive isotopes such as Holmium 166 ( 166 Ho) have potential applications as beta particle emitters in tumour tissues. It is also a gamma ray emitter, allowing nuclear imaging of any tissue to be acquired. It is frequently used in the form of complexes such as holmium acetylacetonate (HoAcAc), which may cause damages in tissues next to the targets cancer cells, as it is difficult to control its linkage or healthy tissues radiotherapy effects. Poly(d,l-lactic acid), PDLLA, was used to encapsulate holmium acetylacetonate (HoAcAc) using an emulsion solvent extraction/evaporation technique. Microspheres with sizes between 20-53 µm were extensively characterised. HoAcAc release from the microspheres was assessed through studies using Inductively Coupled Plasma - Optical Emission Spectroscopy, and the microspheres showed no holmium leakage after a period of 10 half-lives and following gamma irradiation. Thus, HoAcAc loaded microspheres are here presented as a potential system for brachytherapy and imaging purposes.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Rich

    The transition metal yttrium (Y, atomic number 39) is chemically similar to elements in the lanthanide family (atomic numbers 57-71, lanthanum through lutetium) and is always present with the lanthanides in rare earth ores. Yttrium and the lanthanide holmium are particularly close chemical and physical analogues and are referred to as geochemical twins because they typically show little fractionation in geological material. Extensive measurements on rocks, soils, and meteorites indicate that the Y/Ho mass concentration ratio rarely falls far from the “chondritic” or “solar system” ratio of ~26. Our paper presents a new biokinetic model for yttrium in adult humansmore » and examines whether yttrium and holmium may be biological as well as geochemical twins. Collected data on yttrium and holmium in plants and human tissues do not allow precise derivations of Y/Ho concentration ratios but with occasional exceptions yield ratios that are reasonably consistent with chondritic values. Predictions of the time-dependent behavior of yttrium in adult humans based on the yttrium model presented here closely approximate predictions of the behavior of holmium based on a previously developed model for holmium. We know that yttrium and holmium are close biological analogues, but the available comparative data are too limited and imprecise to reveal whether there are any significant differences in their biological behavior.« less

  4. Acute effects of pulsed-laser irradiation on the arterial wall

    NASA Astrophysics Data System (ADS)

    Nakamura, Fumitaka; Kvasnicka, Jan; Lu, Hanjiang; Geschwind, Herbert J.; Levame, Micheline; Bousbaa, Hassan; Lange, Francoise

    1992-08-01

    Pulsed laser coronary angioplasty with an excimer or a holmium-yttrium-aluminum-garnet (Ho:YAG) laser may become an alternative treatment for patients with coronary artery disease. However, little is known about its acute consequences on the normal arterial wall. This study was designed to examine the acute histologic consequences of these two pulsed lasers on the arterial wall of normal iliac arteries in rabbits. Irradiation with each laser was performed in 15 normal iliac sites on eight male New Zealand white rabbits. The excimer laser was operated at 308 nm, 25 Hz, 50 mJ/mm2/pulse, and 135 nsec/pulse and the Ho:YAG laser was operated at 2.1 micrometers , 3/5 Hz, 400 mJ/pulse, and 250 microsecond(s) ec/pulse. The excimer and Ho:YAG laser were coupled into a multifiber wire-guided catheter of 1.4 and 1.5 mm diameter, respectively. The sites irradiated with excimer or Ho:YAG laser had the same kinds of histologic features, consisting of exfoliation of the endothelium, disorganization of internal elastic lamina, localized necrosis of vascular smooth muscle cells, and fissures in the medial layer. However, the sites irradiated with excimer laser had lower grading scores than those irradiated with Ho:YAG laser (p < 0.05). Laser irradiation with excimer or Ho:YAG laser of normal arteries results in localized mechanical vascular injury.

  5. A compact, inexpensive infrared laser system for continuous-wave optical stimulation of the rat prostate cavernous nerves

    NASA Astrophysics Data System (ADS)

    Perkins, William C.; Lagoda, Gwen A.; Burnett, Arthur L.; Fried, Nathaniel M.

    2014-03-01

    Optical nerve stimulation (ONS) has been commonly performed in the laboratory using high-power, pulsed, infrared (IR) lasers including Holmium:YAG, diode, and Thulium fiber lasers. However, the relatively high cost of these lasers in comparison with conventional electrical nerve stimulation (ENS) equipment may represent a significant barrier to widespread adoption of ONS. Optical stimulation of the prostate cavernous nerves (CN's) has recently been reported using lower cost, continuous-wave (CW), all-fiber-based diode lasers. This preliminary study describes further miniaturization and cost reduction of the ONS system in the form of a compact, lightweight, cordless, and inexpensive IR laser. A 140-mW, 1560-nm diode laser was integrated with a green aiming beam and delivery optics into a compact ONS system. Surface and subsurface ONS was performed in a total of 5 rats, in vivo, with measurement of an intracavernous pressure (ICP) response during CW laser irradiation for 30 s with a spot diameter of 0.7 mm. Short-term, CW ONS of the prostate CN's is feasible using a compact, inexpensive, batterypowered IR laser diode system. This ONS system may represent an alternative to ENS for laboratory studies, and with further development, a handheld option for ONS in the clinic to identify and preserve the CN's during prostate cancer surgery.

  6. Generation of 70-fs pulses at 286 μm from a mid-infrared fiber laser

    NASA Astrophysics Data System (ADS)

    Woodward, R. I.; Hudson, D. D.; Fuerbach, A.; Jackson, S. D.

    2017-12-01

    We propose and demonstrate a simple route to few-optical-cycle pulse generation from a mid-infrared fiber laser through nonlinear compression of pulses from a holmium-doped fiber oscillator using a short length of chalcogenide fiber and a grating pair. Pulses from the oscillator with 265-fs duration at 2.86 {\\mu}m are spectrally broadened through self-phase modulation in step-index As2S3 fiber to 141-nm bandwidth and then re-compressed to 70 fs (7.3 optical cycles). These are the shortest pulses from a mid-infrared fiber system to date, and we note that our system is compact, robust, and uses only commercially available components. The scalability of this approach is also discussed, supported by numerical modeling.

  7. Congenital anterior urethral valve with or without diverticulum: a single-centre experience.

    PubMed

    Prakash, Jai; Dalela, Divakar; Goel, Apul; Singh, Vishwajeet; Kumar, Manoj; Garg, Manish; Mandal, Swarnendu; Sankhwar, Satya N; Paul, Sagorika; Singh, Bhupender P

    2013-12-01

    Congenital anterior urethral valves (AUV) are rare and can occur as an isolated entity or in association with proximal diverticula. Diagnosis may be overlooked and ideal treatment is not standardized when both the valve and diverticulum are simultaneously present. We present our experience of congenital AUV. From January 2007 to June 2012 a retrospective review of the medical records of 7 cases of AUV was performed. Three patients were diagnosed as isolated AUV while four presented with associated diverticula. The age of presentation ranged from 10 months to 6 years. Weak voiding stream and dribbling were the most common symptoms. Renal function was found to be deranged in two patients (28%). Hydro-ureteronephrosis was present in three boys (42%) and reflux was present in one patient. Post-void residual volume was >20 ml (mean 55 ml) in all children. Transurethral holmium laser fulguration was carried out on isolated AUV or AUV with small diverticula. Open resection and reconstruction or plication was performed in patients with AUV and proximal large (>3 cm) diverticula. Surgical outcome was successful in all patients except for occurrence of urethrocutaneous fistula in one patient. In isolated AUV or valve with associated small diverticulum, transurethral holmium:YAG laser ablation is the treatment of choice. Primary excision and repair or plication are preferred if a large diverticula has formed. Eventual outcomes of AUV are good if irreversible changes have not been established. Copyright © 2013 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  8. Salvage Holmium laser enucleation of prostate to treat residual benign prostatic hyperplasia.

    PubMed

    Oh, Jin Kyu; Bae, Jungbum; Jeong, Chang Wook; Paick, Jae-Seung; Oh, Seung-June

    2014-03-01

    The Holmium laser enucleation of the prostate (HoLEP) technique to remove residual adenoma has not been reported. Salvage HoLEP enables anatomical enucleation of residual adenoma in patients who have previously undergone surgical treatment. We describe not only anatomical insights into the frequent location of adenoma recurrence, but also the feasibility of the salvage HoLEP technique. We retrospectively reviewed a database containing HoLEP video records for 35 patients out of a total of 535 individuals on whom HoLEP was performed by 2 surgeons (SJO & JSP) between July 2008 and June 2011. Group 1 consisted of patients who underwent salvage HoLEP due to recurring adenoma and Group 2 of patients who underwent HoLEP as an initially surgical management to treat benign prostate hyperplasia (BPH). We compared the dataset of pre-, intra- and postoperative parameters between Groups 1 and 2. In the analysis of the video records of Group 1 (n = 35), there was significant remnant tissue around the verumontanum and the lateral lobes were also incompletely removed by previous conventional procedures. When we compared pre-, intra- and postoperative parameters between the 2 groups, there were no significant differences, including operation time, duration of hospital stay. However, the duration of the catheterization of Group 1 was shorter than that of Group 2 (1.38 ± 0.55 vs. 1.90 ± 1.81 days, p < 0.001). Even for cases of residual BPH, salvage HoLEP is a feasible and effective procedure for treating residual adenoma along the anatomical plane.

  9. Influence of Pelvicaliceal Anatomy on Stone Clearance After Flexible Ureteroscopy and Holmium Laser Lithotripsy for Large Renal Stones.

    PubMed

    Inoue, Takaaki; Murota, Takashi; Okada, Shinsuke; Hamamoto, Shuzo; Muguruma, Kouei; Kinoshita, Hidefumi; Matsuda, Tadashi

    2015-09-01

    This study was performed to evaluate the impact of pelvicaliceal anatomy on stone clearance in patients with remnant fragments in the lower pole after flexible ureteroscopy and holmium laser lithotripsy (fURSL) for renal stones >15 mm. This retrospective study included 67 patients with radiopaque residual fragments (>2 mm) in the lower pole after fURSL for large renal stones (>15 mm). The preoperative infundibular length (IL), infundibular width (IW), infundibulopelvic angle (IPA), and caliceal pelvic height (CPH) were measured using intravenous urography. Multivariate analysis was performed to determine whether any of these measurements affected stone clearance. Of the 67 patients, 55 (82.1%) were stone free (SF) 3 months after fURSL. The anatomic factors significantly favorable for an SF status were a short IL, broad IW, wide IPA, and low CPH. On multivariate analysis, the IPA had a significant influence on an SF status after fURSL (p=0.010). An IPA <30° was a negative risk factor (p=0.019). Postoperative complications occurred in nine patients (13.4%), including Clavien grade I complications in two patients (2.9%), grade II in six patients (8.9%), and grade IIIa in one patient (1.8%). Almost all complications were minor. An IPA <30° is the only negative risk factor for stone clearance after fURSL for large renal stones according to our multivariate analysis. Additional studies are required to further evaluate the characteristics of the pelvicaliceal anatomy influencing stone clearance.

  10. Theoretical branching ratios for the 5I7 to 5I7 levels of Ho(3+) in the garnets A3B2C3O12 (A = Y,La,Lu,Gd; B = Al,Lu,Sc,Ga; C = Al,Ga)

    NASA Technical Reports Server (NTRS)

    Filer, Elizabeth D.; Morrison, Clyde A.; Turner, Gregory A.; Barnes, Norman P.

    1991-01-01

    Results are reported from an experimental study investigating triply ionized holmium in 10 garnets using the point-change model to predict theoretical energy levels and temperature-dependent branching ratios for the 5I7 to 5I8 manifolds for temperatures between 50 and 400 K. Plots were made for the largest lines at 300 K. YScAG was plotted twice, once for each set of X-ray data available. Energy levels are predicted based on theoretical crystal-field parameters, and good agreement to experiment is found. It is suggested that the present set of theoretical crystal-field parameters provides good estimates of the energy levels for the other hosts on which there are no experimental optical data. X-ray and index-of-refraction data are used to evaluate the performance of 10 lasers via a quantum mechanical model to predict the position of the energy levels and the temperature-dependent branching rations of the 5I7 to 5I8 levels of holmium. The fractional population inversion required for threshold is also evaluated.

  11. A cheap minimally painful and widely usable alternative for retrieving ureteral stents.

    PubMed

    Söylemez, Haluk; Sancaktutar, Ahmet Ali; Bozkurt, Yaşar; Atar, Murat; Penbegül, Necmettin; Yildirim, Kadir

    2011-01-01

    To describe a cheap, minimally painful and widely usable method for retrieving ureteral stents by using an ureteroscope. Sixty-seven patients with ureteral stents were enrolled in this study. The patients were randomized into a cystoscopic (35 patients) and a ureteroscopic (32 patients) group. All stents were retrieved by a flexible cystoscope in the first group and by a ureteroscope in the second group under local anesthesia. Patients in each group were assessed for stented time, stent side, cause of stent placement, operative time, peroperative pain, postoperative pain, irritative voiding symptoms and hematuria. Also costs of instruments were calculated. Stents were successfully retrieved in 67 patients. There were no statistical differences in the two groups regarding patient gender and age or stent side, operative time, stented time, mean operative pain score, irritative voiding symptom scores and hematuria. Total selling price was USD 20.399 for flexible instruments and USD 10.516 for rigid ones. Total maintenance price was higher in flexible instruments than in the rigid ones (USD 197.8 and 51.7 per use, respectively). Ureteroscopic stent retrieval is a minimally painful, safe and highly tolerable method under local anesthesia as well as flexible cystoscopic retrieval. Also, it is a cheap and widely usable method. Copyright © 2011 S. Karger AG, Basel.

  12. Ureteral Avulsion Associated with Ureteroscopy: Insights from the MAUDE Database.

    PubMed

    Tanimoto, Ryuta; Cleary, Ryan C; Bagley, Demetrius H; Hubosky, Scott G

    2016-03-01

    Flexible and semirigid ureteroscopy (URS) are widely performed for the treatment of upper tract calculi and tumors. Ureteral avulsion is a rare, but devastating complication of endoscopic stone removal having multiple possible etiologies. Awareness and avoidance of this rare complication depend on identifying responsible mechanisms. This study examines the situations in which ureteral avulsion occurs as described anonymously in the Manufacturer and User facility Device Experience (MAUDE) database. The MAUDE database was systematically reviewed to account for all reported complications of flexible and semirigid URS. Keywords "ureteroscopy, injury, death, malfunction and other" were entered in the database and medical device reports were reviewed to capture any cases resulting in ureteral avulsion. Attention was paid to the type of ureteroscope involved and the mechanism for avulsion. A total of 104 entries were found detailing the reported complications of flexible and semirigid URS. Ureteral avulsion was clearly noted in six reports with flexible (2) and semirigid ureteroscopes (4). Potential mechanisms included locked deflection of a flexible ureteroscope (1), bunching of the distal bending rubber in a flexible ureteroscope (1), scabbard avulsion (3), and stone basketing (1). Although the incidence of ureteral avulsion cannot truly be determined from this study, some potentially novel mechanisms for this rare complication are observed. This may target future educational efforts to maximize awareness and avoidance of this complication.

  13. [The frequency-doubled double-pulse Neodym:YAG laser lithotripter (FREDDY) in lithotripsy of urinary stones. First clinical experience].

    PubMed

    Ebert, A; Stangl, J; Kühn, R; Schafhauser, W

    2003-06-01

    Laser lithotripsy does not play an important role in urinary stone treatment, mostly due to ineffective fragmentation efficiency, and high purchase and maintenance costs. The aim of the following retrospective study was to show the clinical significance and efficiency of an innovative laser lithotripsy system for urinary stone treatment. Between November 1998 and October 1999, 48 patients were treated with the innovative frequency- doubled double-pulse Neodym: YAG laser lithotripter FREDDY. A total of 50 renal units were treated, 43 ureteroscopically, four ureterorenoscopically, three percutaneous-nephroscopically, and one bladder stone cystoscopically. With a median laser operation time of 5 min (range: 1-30 min) and a total procedure duration of 60 min (range: 15-180 min), a stone-free rate of upper ureteral stones of 62%, middle ureteral stones of 91% and distal ureteral stones of 100% were documented on the first day after treatment. In an observation period of 6 months, no complications were seen. In our experience Laser lithotripsy with FREDDY is an effective, simple and reliable method for the treatment of ureteral stones, with low purchase and maintenance costs. The extremely thin and highly flexible quartz fibre may extend the endoscopic spectrum to otherwise poorly accessible upper ureteral stones, the renal pelvis and renal calix stones. Therefore, a prospective validation study for comparison with ballistic lithotriptors is of great interest.

  14. Numerical Response Surfaces of Volume of Ablation and Retropulsion Amplitude by Settings of Ho:YAG Laser Lithotripter

    PubMed Central

    Rutherford, Jonathan; Solomon, Metasebya; Cheng, Brian; Xuan, Jason R.; Gong, Jason; Yu, Honggang; Xia, Michael L. D.; Yang, Xirong; Hasenberg, Thomas; Curran, Sean

    2018-01-01

    Objectives Although laser lithotripsy is now the preferred treatment option for urolithiasis due to shorter operation time and a better stone-free rate, the optimal laser settings for URS (ureteroscopic lithotripsy) for less operation time remain unclear. The aim of this study was to look for quantitative responses of calculus ablation and retropulsion by performing operator-independent experiments to determine the best fit versus the pulse energy, pulse width, and the number of pulses. Methods A lab-built Ho:YAG laser was used as the laser pulse source, with a pulse energy from 0.2 J up to 3.0 J and a pulse width of 150 μs up to 1000 μs. The retropulsion was monitored using a high-speed camera, and the laser-induced craters were evaluated with a 3-D digital microscope. The best fit to the experimental data is done by a design of experiment software. Results The numerical formulas for the response surfaces of ablation speed and retropulsion amplitude are generated. Conclusions The longer the pulse, the less the ablation or retropulsion, while the longer pulse makes the ablation decrease faster than the retropulsion. The best quadratic fit of the response surface for the volume of ablation varied nonlinearly with pulse duration and pulse number. PMID:29707187

  15. The role of lasers in modern urology.

    PubMed

    Dołowy, Łukasz; Krajewski, Wojciech; Dembowski, Janusz; Zdrojowy, Romuald; Kołodziej, Anna

    2015-01-01

    The functioning of modern urological departments and the high level of service they provide is possible through, among other things, the use of modern laser techniques. Open operations have been replaced by minimally invasive procedures, and classical surgical tools by advanced lasers. The search for new applications with lasers began as technology developed. Among many devices available, holmium, diode and thulium lasers are currently the most popular. Depending on the wavelength, the absorption by water and hemoglobin and the depth of penetration, lasers can be used for coagulation, vaporization and enucleation. In many centres, after all the possibilities of pharmacological treatment have been exhausted, lasers are used as the primary treatment for patients with benign prostatic hyperplasia, with therapeutic results that are better than those obtained through open or endoscopic operations. The use of lasers in the treatment of urolithiasis, urinary strictures and bladder tumours has made treatment of older patients with multiple comorbidities safe, without further necessity to modify the anticoagulant drug treatment. Laser procedures are additionally less invasive, reduce hospitalization time and enable a shorter bladder catheterization time, sometimes even eliminating the need for bladder catherterization completely. Such procedures are also characterized by more stable outcomes and a lower number of reoperations. There are also indications that with the increased competition among laser manufacturers, decreased purchase and maintenance costs, and increased operational safety, laser equipment will become mandatory and indispensable asset in all urology wards.

  16. IN VITRO COMPARISON OF MAXIMUM PRESSURE DEVELOPED BY IRRIGATION SYSTEMS IN A KIDNEY MODEL.

    PubMed

    Proietti, Silvia; Dragos, Laurian; Somani, Bhaskar K; Butticè, Salvatore; Talso, Michele; Emiliani, Esteban; Baghdadi, Mohammed; Giusti, Guido; Traxer, Olivier

    2017-04-05

    To evaluate in vitro the maximum pressure generated in an artificial kidney model when people of different levels of strengths used various irrigation systems. Fifteen people were enrolled and divided in 3 groups based on their strengths. Individual strength was evaluated according to the maximum pressure each participant was able to achieve using an Encore™ Inflator. The irrigation systems evaluated were: T-FlowTM Dual Port, HilineTM, continuous flow single action pumping system (SAPSTM) with the system close and open, Irri-flo IITM, a simple 60-ml syringe and PeditrolTM . Each irrigation system was connected to URF-V2 ureteroscope, which was inserted into an artificial kidney model. Each participant was asked to produce the maximum pressure possible with every irrigation device. Pressure was measured with the working channel (WC) empty, with a laser fiber and a basket inside. The highest pressure was achieved with the 60 ml-syringe system and the lowest with SAPS continuous version system (with continuous irrigation open), compared to the other irrigation devices (p< 0.0001). Irrespective of the irrigation system, there was a significant difference in the pressure between the WC empty and when occupied with the laser fiber or the basket inside it (p<0.0001). The stratification between the groups showed that the most powerful group could produce the highest pressure in the kidney model with all the irrigation devices in almost any situation. The exception to this was the T-Flow system, which was the only device where no statistical differences were detected among these groups. The use of irrigation systems can often generate excessive pressure in an artificial kidney model, especially with an unoccupied WC of the ureteroscope. Depending on the strength of force applied, very high pressure can be generated by most irrigation devices irrespective of whether the scope is occupied or not.

  17. Learning curves and perioperative outcomes after endoscopic enucleation of the prostate: a comparison between GreenLight 532-nm and holmium lasers.

    PubMed

    Peyronnet, Benoit; Robert, Grégoire; Comat, Vincent; Rouprêt, Morgan; Gomez-Sancha, Fernando; Cornu, Jean-Nicolas; Misrai, Vincent

    2017-06-01

    To compare the learning curves, perioperative and early functional outcomes after HoLEP and GreenLEP. Data from the first 100 consecutive cases treated by GreenLEP and HoLEP by two surgeons were prospectively collected from dedicated databases and analysed retrospectively. En-bloc GreenLEP and two-lobar HoLEP enucleations were conducted using the GreenLight HPS™ 2090 laser and Lumenis™ holmium laser. Patients' characteristics, perioperative outcomes and functional outcomes after 1, 3 and 6 months were compared between groups. Total energy delivered and operative times were significantly shorter for GreenLEP (58 vs. 110 kJ, p < 0.0001; 60 vs. 90 min, p < 0.0001). Operative time reached a plateau after 30 procedures in each group. Length of catheterization and hospital stay were significantly shorter in the HoLEP group (2 vs. 1 day, p < 0.0001; 2 vs. 1 day, p < 0.0001). Postoperative complications were comparable between GreenLEP and HoLEP (19 vs. 25 %; p = 0.13). There was a greater increase of Q max at 3 months and a greater IPSS decrease at 1 month for GreenLEP, whereas decreases in IPSS and IPSS-Q8 at 6 months were greater for HoLEP. Transient stress urinary incontinence was comparable between both groups (6 vs. 9 % at 3 months; p = 0.42). Pentafecta was achieved in four consecutive patients after the 18th and the 40th procedure in the GreenLEP and HoLEP group, respectively. Learning curves ranged from 14 to 30 cases for GreenLEP and 22 to 40 cases for HoLEP. Learning curves of GreenLEP and HoLEP provided roughly similar peri-operative and short-term functional outcomes.

  18. Visual internal urethrotomy for management of urethral strictures in boys: a comparison of short-term outcome of holmium laser versus cold knife.

    PubMed

    Aboulela, Waseem; ElSheemy, Mohammed S; Shoukry, Mahmoud; Shouman, Ahmed M; Shoukry, Ahmed I; Ghoneima, Waleed; El Ghoneimy, Mohamed; Morsi, Hany A; Mohsen, Mostafa Abdel; Badawy, Hesham

    2018-04-01

    To compare efficacy and safety of visual internal urethrotomy (VIU) using holmium laser (Ho:YAG) (group A) versus cold knife (group B) in children with urethral strictures. It may be the first comparative study on this issue in children. This study compared Ho:YAG group, which was evaluated prospectively from January 2014 till January 2016, versus cold knife group, which was a historical control performed from March 2008 till February 2010. Children ≤ 13 years old with urethral strictures ≤ 1.5 cm were included successively. Recurrent cases, congenital obstructions and cases with complete arrest of dye in voiding cystourethrography were excluded. Scar tissue was incised at twelve o'clock. Outcome was compared using Student's t, Mann-Whitney, Chi-square or Fisher exact tests as appropriate. Each group included 21 patients. Mean age was 6.27 ± 3.23 (2-13) years old. Mean stricture length was 1.02 versus 1 cm in group A versus B, respectively (p = 0.862). Ten cases of penile/bulbous strictures and another 11 cases of membranous strictures were found in each group. There was no significant difference between both groups in preoperative data. Success rate for initial VIU was 66.7% in group A versus 38% in group B (p = 0.064). This was associated with significantly higher Q max in group A (mean 16.52 vs 12.09 ml/s; p = 0.03). Success rate after two trials of VIU was 76.2% for group A and 47.61% for group B (p = 0.057). No complications were reported in both groups. Laser VIU has a higher success rate than cold knife VIU for urethral strictures ≤ 1.5 cm in children with significantly higher Q max . Both are easy to perform, low invasive and safe.

  19. Development of mid-infrared solid state lasers for spaceborne lidar

    NASA Technical Reports Server (NTRS)

    Whitney, Donald A.

    1990-01-01

    Researchers investigated laser performance of Ho(3+):Tm(3+):Cr(3+):YAG crystals under both Cr:GSAG laser and flashlamp pumping. A flashlamp pumped Cr:GSAG laser was built to simulate high power quasi-CW laser diode pumping of a 2.1 micron holmium laser. The 2.1 micron output laser energy exceeded more than 14 mJ, the highest value reported to date under laser pumping near 785 nm. This was obtained in a pulse length of nearly 650 microns from a 3 x 3 mm Ho:Tm:Cr:YAG rod by using the flashlamp-pumped Cr:GSAG laser as a pumping source at the diode laser wavelength, 785 microns. In addition, Ho:Tm:Cr:YAG crystals with various Tm(3+) concentrations have been evaluated for flashlamp-pumped normal mode and Q-switched 2.1 micron laser operations under a wide variety of experimental conditions in order to understand internal dynamic processes among the ions and to determine an optimum lasing condition. An increase of the laser slope efficiency was observed with the increase of the Tm(3+) concentration from 2.5 atomic percent to 4.5 atomic percent. The thermal dependence of the laser performance was also investigated. Q-switched laser output energies corresponding to nearly 100 percent of the normal-mode laser energies were obtained in a strong single spike of 200 ns pulse length by optimizing the opening time of a lithium niobate Q-switch.

  20. Thermal property of holmium doped lithium lead borate glasses

    NASA Astrophysics Data System (ADS)

    Usharani, V. L.; Eraiah, B.

    2018-04-01

    The new glass system of holmium doped lithium lead borate glasses were prepared by conventional melt quenching technique. The thermal stability of the different compositions of Ho3+ ions doped lithium lead borate glasses were studied by using TG-DTA. The Tg values are ranging from 439 to 444 °C with respect to the holmium concentration. Physical parameters like polaron radius(rp), inter-nuclear distance (ri), field strength (F) and polarizability (αm) of oxide ions were calculated using appropriate formulae.

  1. Effects of holmium:YAG laser on equine articular cartilage and subchondral bone adjacent to traumatic lesions

    NASA Astrophysics Data System (ADS)

    Collier, Michael A.; Haugland, L. Mark; Bellamy, Janine; Johnson, Lanny L.; Rohrer, Michael D.; Walls, Robert C.; Bartels, Kenneth E.

    1994-09-01

    The effects of Ho:YAG laser energy on articular cartilage and subchondral bone adjacent to traumatically created cartilage lesions in a continuous weight-bearing model were investigated. The 2.1 micrometers wavelength was delivered in hand-controlled contact and near-contact hard tissue arthroscopic surgery in a saline medium. Bilateral arthroscopy was performed on normal antebrachiocarpal and intercarpal joints of four adult horses. One-hundred twenty traumatic lesions were created on three weight-bearing articular surfaces with a knife, curette, or a motorized burr. Depths of the lesions were partial and full thickness. Configurations of the lesions were lacerations, scrapes, and craters. Left limbs were used as controls. Right limb lesions were treated with various intensities of laser energy. Animals were sacrificed at intervals of 1, 3, and 8 weeks. Gross microscopic anatomy was documented, and tissue sections were subjected to blind review by a pathologist. Mankin grading for cellularity and proteoglycan content was used to qualitatively evaluate cartilage response. Cartilage adjacent to all lesions exposed to laser energy had better cellularity and proteoglycan content than corresponding controls by Mankin grading.

  2. Corneal collagen denaturation in laser thermokeratoplasty

    NASA Astrophysics Data System (ADS)

    Brinkmann, Ralf; Kampmeier, Juergen; Grotehusmann, Ulf; Vogel, Alfred; Koop, Norbert; Asiyo-Vogel, Mary; Birngruber, Reginald

    1996-05-01

    In laserthermokeratoplasty (LTK) thermal denaturation and shrinkage of corneal collagen is used to correct hyperopia and astigmatism. In order to optimize dosimetry, the temperature at which maximal shrinkage of collagen fibrils occurs is of major interest. Since the exposure time in clinical LTK-treatment is limited to a few seconds, the kinetics of collagen denaturation as a rate process has to be considered, thus the time of exposure is of critical importance for threshold and shrinkage temperatures. We investigated the time-temperature correlation for corneal collagen denaturation within different time domains by turbidimetry of scattered HeNe laser probe light using a temperature controlled water bath and pulsed IR laser irradiation. In the temperature range of 60 degree(s)C to 95 degree(s)C we found an exponential relation between the denaturation time and temperature. For the typical LTK-treatment time of 2 s, a temperature of 95 degree(s)C is needed to induce thermal damage. Use of pulsed Holmium laser radiation gave significant scattering of HeNe laser probe light at calculated temperatures of around 100 degree(s)DC. Rate parameters according to the formalism of Arrhenius were fitted to these results. Force measurements showed the simultaneous onset of light scattering and collagen shrinkage.

  3. Holmium laser use in debridement of stable labral lesions: two-year experience in initial 50 patients

    NASA Astrophysics Data System (ADS)

    Dew, Douglas K.; Risch, E. David

    1994-09-01

    The purpose of this study is to determine the laser related complication rate for shoulder arthroscopy in the initial clinical experience of 50 patients, and to identify potential advantages of laser use in shoulder arthroscopy. Fifty patients spanning ages 25 to 87 were treated. Surgical debridement was selective and conservative creating a smooth post resection rim. In those that included rotator cuff tears, in addition to arthroscopic debridement, a mini arthrotomy and open acromioplasty were performed. Changes in arthroscopic technique due to laser use included no arthroscopic pump use and use of the shaver only when the fiber could not be easily seen with severe synovitis. We found that the hyper-vascular synovium did not need to be resected last, it could be resected at any point during the procedure. Four hundred and 600 micron fiberoptics were used as well as 20 watts average power. Technical advantage of the laser was felt to be the size of the instrument probe and the availability of excellent hemostasis. Complications include one case of arthroscope damage and one case with a broken fiber tip which was removed with a grasper. Long term follow up of these patients is now underway.

  4. Prostatic vascular damage induced by cigarette smoking as a risk factor for recovery after holmium laser enucleation of the prostate (HoLEP)

    PubMed Central

    Gu, Meng; Chen, Yanbo; Cai, Zhikang; Chen, Qi; Wang, Zhong

    2017-01-01

    Purpose To evaluate the relationship between prostatic vessel changes induced by cigarette smoking and the perioperative outcome of holmium laser enucleation of the prostate (HoLEP). Materials and Methods A total of 268 postoperative patients with benign prostatic hyperplasia (BPH) were prospectively analysed in our department. They were divided into two groups (smokers and non-smokers) according to smoking history. Transrectal colour Doppler ultrasound was performed to evaluate the prostate vascular changes. Pathologically, HE staining, CD31 and CD34 were analysed in prostatic section chips. Furthermore, postoperative outcomes were determined during a 6-month follow-up period. Results The preoperative prostate volume was significantly decreased in smoking patients (P = 0.04). CPI was significantly lower in smoking BPH patients (P < 0.01), whereas RI was significantly increased in smokers compared with non-smokers (P < 0.01). Histological assays revealed elevated CD34 in the smoking BPH individuals presenting an increased number of microvessels. The HoLEP duration was increased in smokers. Interestingly, we identified significantly increased overactive bladder syndrome score (OABSS) and decreased Qmax in smoking individuals during the 6-month follow-up with no difference being observed preoperatively. However, no significant difference between the groups was observed for the International Prostate Symptom Score (IPSS). Conclusions The significantly lower CPI and higher RI values in smoking BPH patients indicated the presence of considerable vascular damage in these subjects. Moreover, cigarette smoking extended the surgical duration and prolonged the recovery period of overactive bladder (OAB) syndrome. Thus, integrated treatment should be suggested for various BPH individuals. PMID:27732940

  5. Occupational noise exposure during endourologic procedures.

    PubMed

    Soucy, Frédéric; Ko, Raymond; Denstedt, John D; Razvi, Hassan

    2008-08-01

    Long-term noise exposure in the workplace is a known cause of hearing loss. There has been limited study on the potential harm related to shock wave lithotripsy (SWL) or intracorporeal devices on patients and operating room personnel. We used a digital sound meter to measure decibel levels in the operating room during several endourologic procedures. The decibel levels were recorded during SWL (Storz SLX-F2), percutaneous nephrolithotomy using single- and dual-probe ultrasonic lithotripters (Olympus LUS-2, CyberWand), and during ureteroscopy using the Versa Pulse Holmium:YAG laser. Findings were compared with the U.S. Department of Labor Occupational Health and Safety Administration and Canadian Centre for Occupational Health recommendations on permissible noise levels in the workplace. The background sound level in the operating room prior to endourologic procedures ranged between 58 and 60 dB. In the SWL control room, 5 m from the source, the mean sound level was 68 dB (range 64-75) during treatment. The mean corresponding decibel level recorded at the patient's head during SWL was 77 dB (range 73-83). Noises produced by intracorporeal lithotripters were recorded at the surgeon's head, 2 m from the source. Measurements of the CyberWand (dual-probe) device revealed a higher mean decibel reading of 93 dB (range 85-102). Noise levels recorded for the Olympus LUS-2 (single-probe) ultrasound and the holmium laser were 65 dB (62 -68) and 60 dB (58-62), respectively. Although we noted that patients and urologists maybe exposed to significant noise levels during endourologic procedures, the duration of exposure is short. This risk appears to be minimal, based on current occupational guidelines, for most operating personnel.

  6. Holmium laser enucleation of the prostate and retropubic prostatic adenomectomy: morbidity analysis and anesthesia considerations.

    PubMed

    Soto-Mesa, D; Amorín-Díaz, M; Pérez-Arviza, L; Fernández-Pello Montes, S; Martín-Huéscar, A

    2015-11-01

    Holmium laser enucleation of the prostate (HoLEP) is an alternative to prostatic adenomectomy for the surgical treatment of benign prostatic hypertrophy. We analyzed our learning curve for this technique, and we compared it in a secondary manner with prostatic adenomectomy. A retrospective comparative study was conducted that included the first 100 cases of HoLEP performed in our center and the latest 50 cases of retropubic adenomectomy. We collected data on the patients, the surgery, the anesthesia, the perioperative variables, the anesthesia complications and the postoperative variables, with a 6-month follow-up. We analyzed the learning curve without mentors for HoLEP and compared the characteristics of HoLEP in 2 separate phases (learning and stabilization phases) with the latest retropubic prostatic adenomectomies performed. Intradural anesthesia was the most common technique. The transfusion needs, length of stay (P<.01) and postoperative morbidity were lower for HoLEP than for adenomectomy. However, the retropubic adenomectomy group had larger initial prostate volumes (P<.001) and shorter surgical times (P<.001). Better surgical performance (P<.001) and a lower incidence of complications were observed in the HoLEP-B group (once the learning curve had been overcome) compared with the HoLEP-A group. In our center, HoLEP was introduced as a valid alternative to open retropubic adenomectomy, with excellent results in terms of morbidity and reduced hospital stay. In terms of the learning curve, we consider that approximately 50 patients (without mentor) is an appropriate cutoff. Local anesthesia is a good choice for the anesthesia technique. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Efficacy of holmium laser enucleation of the prostate (HoLEP) in men with bladder outlet obstruction (BOO) and non-neurogenic bladder dysfunction.

    PubMed

    Pyun, Jong Hyun; Kang, Sung Gu; Kang, Seok Ho; Cheon, Jun; Kim, Je Jong; Lee, Jeong Gu

    2017-09-01

    We aimed to compare the short-term outcomes of men who had urodynamic evidence of detrusor underactivity (DU) or detrusor overactivity (DO) of a non-neurogenic etiology as well as bladder outlet obstruction (BOO) and who underwent Holmium Laser Enucleation of the prostate (HoLEP). A database of 322 patients who underwent HoLEP between 2010 and 2014 was analyzed. Patients were classified into three groups according to the results of a preoperative urodynamic study. Preoperative parameters such as International Prostate Symptom Score (IPSS), Quality of Life (QoL) index, IPSS grade, uroflowmetry were compared with postoperative parameters measured at 6 months. There were 138 patients with BOO-only and 89 patients with BOO and detrusor dysfunction including 56 with DO and 33 with DU. The degree of improvement in IPSS-total (BOO: 10.7, DO: 8.3, DU: 7.0; p = 0.023) was greater in the BOO-only group than in the DU group. There were more patients whose IPSS grade improved in the BOO-only group (71%) than in the detrusor dysfunction group (DO: 53.6% and DU: 45.5%). Postoperative IPSS-voiding (4.5 vs 7.0), and Qmax (18 vs 13.7) in the BOO-only group were significantly better than those in the DU group. Additionally, postoperative IPSS-storage (4.7 vs 6.7), and IPSS-total (9.1 vs 12.3) in the BOO-only group were significantly better than in the DO group (all p < 0.05). In conclusion, early surgical management for men with severe LUTS and associated BPH before secondary degeneration occurs may be beneficial for preserving detrusor function and yield better treatment outcomes. Copyright © 2017. Published by Elsevier Taiwan.

  8. Preparation of artificial kidney stones of reproducible size, shape, and mass by precision injection molding.

    PubMed

    Carey, Robert I; Kyle, Christopher C; Carey, Donna L; Leveillee, Raymond J

    2008-01-01

    To prepare artificial kidney stones of defined shape, size, mass, and material composition via precision injection molding of Ultracal 30 cement slurries into an inexpensive biodegradable mold. A calcium alginate and silica-based mold was used to prepare casts of varying shapes in a reproducible manner. Ultracal 30 cement slurries mixed 1:1 with water were injected into these casts and allowed to harden. The artificial stones were recovered and their physical properties determined. Ex-vivo and in-vivo responses to holmium laser lithotripsy were examined. Spheres, half spheres, cylinders, cubes, tapered conical structures, and flat angulated structures were prepared with high precision without post-molding manipulations. Large spheres of average mass 0.661 g (+/- 0.037), small spheres of average mass 0.046 g (+/- 0.0026), and hexagons of average mass 0.752 g (+/- 0.0180) were found to have densities (1610-1687 kg/m(3)) within the expected range for Ultracal 30 cement stones. Ex-vivo holmium laser lithotripsy of small spheres in saline showed uniformly reproducible efficiencies of comminution. Implantation of a tapered conical stone into the ureter of a porcine model demonstrated stone comminution in vivo consistent with that seen in the ex-vivo models. We present an environmentally safe, technically simple procedure for the formation of artificial kidney stones of predetermined size and shape. The technique does not require the use of hazardous solvents or postprocedural processing of the stones. These stones are intended for use in standardized experiments of lithotripsy efficiency in which the shape of the stone as well as the mass can be predetermined and precisely controlled.

  9. Serial Changes in Sexual Function Following Holmium Laser Enucleation of the Prostate: A Short-term Follow-up Study.

    PubMed

    Jeong, Min Su; Ha, Seung Beom; Lee, Chang Ju; Cho, Min Chul; Kim, Soo Woong; Paick, Jae-Seung

    2012-02-01

    To evaluate the serial changes in sexual function in the short-term period after holmium laser enucleation of the prostate (HoLEP) for benign prostatic hyperplasia (BPH) and to investigate whether a change in each domain of the International Index of Erectile Function (IIEF) is associated with improvement of micturition. Thirty-eight potent men who underwent HoLEP and in whom complete 12-month follow-up data on the IIEF were available were included in this retrospective study. All patients underwent a baseline evaluation for BPH. The surgical outcome was evaluated at 1, 3, 6, and 12 months postoperatively by use of the International Prostate Symptom Score, IIEF, and uroflowmetry. The mean age and body mass index of the patients was 64.5±6.2 years and 24.2±2.6 kg/m(2), respectively. Mean total prostate volume and transitional zone volume were 48.8±18.8 ml and 24.2±16.1 ml, respectively. Most IIEF domain scores showed a slight decrease at 1, 3, and 6 months after surgery but recovered to the baseline or showed a marginal but nonsignificant increase at 12 months postoperatively compared with baseline. Orgasmic function and the overall sexual satisfaction domain score remained slightly reduced up to 12 months postoperatively. There was no significant correlation between improvement of micturition and change in sexual function throughout the follow-up period after surgery. Although HoLEP achieves significant improvements in micturition, overall sexual function decreases slightly in the early postoperative period, but recovers to the baseline at 12 months postoperatively. Our data suggest that changes in sexual function after HoLEP are not associated with improvement of micturition.

  10. The role of lasers in modern urology

    PubMed Central

    Dołowy, Łukasz; Dembowski, Janusz; Zdrojowy, Romuald; Kołodziej, Anna

    2015-01-01

    Introduction The functioning of modern urological departments and the high level of service they provide is possible through, among other things, the use of modern laser techniques. Material and methods Open operations have been replaced by minimally invasive procedures, and classical surgical tools by advanced lasers. The search for new applications with lasers began as technology developed. Among many devices available, holmium, diode and thulium lasers are currently the most popular. Results Depending on the wavelength, the absorption by water and hemoglobin and the depth of penetration, lasers can be used for coagulation, vaporization and enucleation. In many centres, after all the possibilities of pharmacological treatment have been exhausted, lasers are used as the primary treatment for patients with benign prostatic hyperplasia, with therapeutic results that are better than those obtained through open or endoscopic operations. The use of lasers in the treatment of urolithiasis, urinary strictures and bladder tumours has made treatment of older patients with multiple comorbidities safe, without further necessity to modify the anticoagulant drug treatment. Laser procedures are additionally less invasive, reduce hospitalization time and enable a shorter bladder catheterization time, sometimes even eliminating the need for bladder catherterization completely. Such procedures are also characterized by more stable outcomes and a lower number of reoperations. Conclusions There are also indications that with the increased competition among laser manufacturers, decreased purchase and maintenance costs, and increased operational safety, laser equipment will become mandatory and indispensable asset in all urology wards. PMID:26251737

  11. Impact of pulse duration on Ho:YAG laser lithotripsy: fragmentation and dusting performance.

    PubMed

    Bader, Markus J; Pongratz, Thomas; Khoder, Wael; Stief, Christian G; Herrmann, Thomas; Nagele, Udo; Sroka, Ronald

    2015-04-01

    In vitro investigations of Ho:YAG laser-induced stone fragmentation were performed to identify potential impacts of different pulse durations on stone fragmentation characteristics. A Ho:YAG laser system (Swiss LaserClast, EMS S.A., Nyon, Switzerland) with selectable long or short pulse mode was tested with regard to its fragmentation and laser hardware compatibility properties. The pulse duration is depending on the specific laser parameters. Fragmentation tests (hand-held, hands-free, single-pulse-induced crater) on artificial BEGO stones were performed under reproducible experimental conditions (fibre sizes: 365 and 200 µm; laser settings: 10 W through combinations of 0.5, 1, 2 J/pulse and 20, 10, 5 Hz, respectively). Differences in fragmentation rates between the two pulse duration regimes were detected with statistical significance for defined settings. Hand-held and motivated Ho:YAG laser-assisted fragmentation of BEGO stones showed no significant difference between short pulse mode and long pulse mode, neither in fragmentation rates nor in number of fragments and fragment sizes. Similarly, the results of the hands-free fragmentation tests (with and without anti-repulsion device) showed no statistical differences between long pulse and short pulse modes. The study showed that fragmentation rates for long and short pulse durations at identical power settings remain at a comparable level. Longer holmium laser pulse duration reduces stone pushback. Therefore, longer laser pulses may result in better clinical outcome of laser lithotripsy and more convenient handling during clinical use without compromising fragmentation effectiveness.

  12. Using transurethral Ho:YAG-laser resection to treat urethral stricture and bladder neck contracture

    NASA Astrophysics Data System (ADS)

    Bo, Juanjie; Dai, Shengguo; Huang, Xuyuan; Zhu, Jing; Zhang, Huiguo; Shi, Hongmin

    2005-07-01

    Objective: Ho:YAG laser had been used to treat the common diseases of urinary system such as bladder cancer and benign prostatic hyperplasia in our hospital. This study is to assess the efficacy and safety of transurethral Ho:YAG-laser resection to treat the urethral stricture and bladder neck contracture. Methods: From May 1997 to August 2004, 26 cases of urethral stricture and 33 cases of bladder neck contracture were treated by transurethral Ho:YAG-laser resection. These patients were followed up at regular intervals after operation. The uroflow rate of these patients was detected before and one-month after operation. The blood loss and the energy consumption of holmium-laser during the operation as well as the complications and curative effect after operation were observed. Results: The therapeutic effects were considered successful, with less bleeding and no severe complications. The Qmax of one month postoperation increased obviously than that of preoperation. Of the 59 cases, restenosis appeared in 11 cases (19%) with the symptoms of dysuria and weak urinary stream in 3-24 months respectively. Conclusions: The Ho:YAG-laser demonstrated good effect to treat the obstructive diseases of lower urinary tract such as urethral stricture and bladder neck contracture. It was safe, minimal invasive and easy to operate.

  13. Safety and efficacy of silodosin and tadalafil in ease of negotiation of large ureteroscope in the management of ureteral stone: A prosective randomized trial.

    PubMed

    Bhattar, Rohit; Jain, Vipin; Tomar, Vinay; Yadav, Sher Singh

    2017-12-01

    To evaluate the safety and efficacy of silodosin and tadalafil in ease of negotiation of large size ureteroscope (8/9.8 Fr) in the management of ureteral stone. Between June 2015 and May 2016, 86 patients presented with ureteral stone of size 6-15 mm were on consent randomly assigned to 1 of 3 outpatient treatment arms: silodosin (Group A), tadalafil (Group B), and placebo (Group C). After two weeks of therapy 67 patients underwent ureteroscopy, and ureteral orifice configuration, ureteroscopic negotiation, ureteral dilatation, operating time, procedural complication and drug related side effects were noted in each group. Ureteral negotiation was significantly better in Groups A (73.9%) and B (69.6%) as compared to Group C (38.1%) (p<0.01). Statistically significant difference was noted in the requirement for dilatation in Group C (71.4%) as compared to Groups A (26.1%) and B (39.1%) (p<0.01). Ureteral orifice was found to be more dilated in Groups A (69.6%) and B (60.9%) as compared to Group C (28.6%). Mean operating time was statistically lower in Groups A (35.2 min) and B (34.91 min) as compared to Group C (41.14 min) (p<0.01). Both silodosin and tadalafil not only relax ureteral smooth muscle but also help in forward propagation of large size ureteroscope (8/9.8 Fr) without any significant risk of adverse events.

  14. Ureteroscopic skills with and without Roboflex Avicenna in the K-box® simulator.

    PubMed

    Proietti, Silvia; Dragos, Laurian; Emiliani, Esteban; Butticè, Salvatore; Talso, Michele; Baghdadi, Mohammed; Villa, Luca; Doizi, Steeve; Giusti, Guido; Traxer, Olivier

    2017-01-01

    The aim of this study was to evaluate the acquisition of basic ureteroscopic skills with and without Roboflex Avicenna by subjects with no prior surgical training. Ten medical students were divided in two groups: Group 1 was trained with Roboflex Avicenna and Group 2 with flexible ureteroscope alone, using the K-box ® simulator model. Participants were scored on their ability to perform or not two exercises, recording the time. In addition, the participants were evaluated on the quality of their performance for the following parameters: respect of the surrounding environment, flow of the operation, orientation, vision centering and stability. The first exercise was completed only by three and four out of five of students in Group 1 and Group 2, respectively. Stability with the scope was significantly more accurate in the first group compared with the second (P = 0.02). There were no differences in timing, flow or orientation between groups. Although not significant, a tendency of respecting the surrounding tissue and maintaining centered vision was perceived more in the first group. As for the second exercise, there were no differences between groups in regard of orientation, flow, respecting the surrounding tissue, stability or the ability of maintaining centered vision. Although not significant, the second group had a tendency of performing the exercise faster. According to these preliminary results, the acquisition of basic ureteroscopic skills with and without robotic fURS in the K-box ® simulator, by subjects with no prior surgical training, is similar.

  15. Ho-nanoparticle-doping for improved high-energy laser fibers

    NASA Astrophysics Data System (ADS)

    Friebele, E. Joseph; Baker, Colin C.; Burdett, Ashley A.; Rhonehouse, Daniel L.; Bowman, Steven R.; Kim, Woohong; Sanghera, Jasbinder S.; Kucera, Courtney; Vargas, Amber; Ballato, John; Hemming, Alexander; Simakov, Nikita; Haub, John

    2017-02-01

    A significant issue for holmium-doped fiber lasers (HoDFLs) operating near 2 μm is multiphonon quenching due to the high phonon energy 1100 cm-1 of the silica host, which complicates power scaling due to reduced lifetimes and increased heating. Nanoparticle (NP) doping is a new technique where the structure surrounding the Ho ions is developed chemically prior to doping into the silica core. We have incorporated Ho3+ ions into various NPs, such as LaF3, Al2O3 and Lu2O3, to shield them from the silica glass matrix. Results indicate slightly longer lifetimes with Ho:LaF3 NPs and the possibility of further improvement with oxide NPs. We report the first of lasing in a Ho:Lu2O3 NP-doped fiber pumped at 1.95 μm and operating at 2.09 μm with a record slope efficiency of 85.2%.

  16. Invasive fungal bezoar requiring partial cystectomy.

    PubMed

    Sundi, Debasish; Tseng, Kenneth; Mullins, Jeffrey K; Marr, Kieren A; Hyndman, Matthew Eric

    2012-02-01

    A 67-year-old man developed dysuria and position-dependent obstructive voiding symptoms after undergoing holmium laser ablation of the prostate (HOLAP) for benign prostatic hypertrophy. A large fungal (candidal) ball adherent to the bladder wall was removed by loop excision, but the bezoar recurred in 2 weeks despite systemic fluconazole and intravesical amphotericin B. A second attempt at endoscopic removal with ultrasonic lithotripsy, endoscopic graspers, and fulguration was also unsuccessful. The patient underwent open partial cystectomy to remove his invasive fungal bezoar. Convalescence was unremarkable. Urinalysis, culture, and follow-up cystoscopy after partial cystectomy demonstrated successful definitive treatment of the fungal ball. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Bilateral complete ureteral duplication with calculi obstructing both limbs of left double ureter.

    PubMed

    Aiken, William D; Johnson, Peter B; Mayhew, Richard G

    2015-01-01

    A woman with bilateral complete ureteral duplication with stones simultaneously obstructing both limbs of the left double ureter is presented. A search of the English medical literature suggests that this is the first reported case. Based on the initial difficulty accessing the stones via ureteroscopy we make recommendations regarding how this rare problem should be approached if encountered. A 37-year old woman with left-sided flank pain was discovered on CT scan to have bilateral complete ureteral duplication and three stones obstructing both limbs of the left double ureter. Ureteroscopy was initially unsuccessful due to the very small calibre and unyielding nature of the ureters and both ureteral limbs were stented. Repeat ureteroscopy was easily achieved after pre-stenting and the impacted stones were completely cleared with intracorporeal laser lithotripsy. The smaller calibre of both double ureters and their presence in a common adventitial sheath distally, made initial attempts at ureteroscopy difficult. Stenting both limbs increased ureteral compliance, passively dilated both ureters and allowed for improved manoeuvrability and retrograde passage of the ureteroscope. Based on the experience with this first reported case it is recommended that pre-stenting should be routinely performed prior to any attempt at ureteroscopy in cases of stones complicating completely duplicated ureters. We report the first recorded case of bilateral complete ureteral duplication with stones simultaneously obstructing both limbs of the double ureter and recommend that routine pre-stenting be done prior to ureteroscopy to allow easy uncomplicated retrograde passage of the ureteroscope. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Neutron-activatable radionuclide cancer therapy using graphene oxide nanoplatelets.

    PubMed

    Kim, Junghyun; Jay, Michael

    2017-09-01

    Neutron-activation is a promising method of generating radiotherapeutics with minimal handling of radioactive materials. Graphene oxide nanoplatelets (GONs) were examined as a carrier for neutron-activatable holmium with the purpose of exploiting inherent characteristics for theranostic application. GONs were hypothesized to be an ideal candidate for this application owing to their desirable characteristics such as a rigid structure, high metal loading capacity, low density, heat resistance, and the ability to withstand harsh environments associated with the neutron-activation process. Non-covalently PEGylated GONs (GONs-PEG) offered enhanced dispersibility and biocompatibility, and also exhibited increased holmium loading capacity nearly two-fold greater than GONs. Holmium leaching was investigated over a wide pH range, including conditions that mimic the tumor microenvironment, following neutron irradiation. The in vitro cell-based cytotoxicity analysis of GONs-based formulations with non-radioactive holmium confirmed their safety profile within cells. The results demonstrate the potential of GONs as a carrier of neutron-activatable radiotherapeutic agents. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Optimization of a novel Tm fiber laser lithotripter in terms of stone ablation efficiency and retropulsion reduction

    NASA Astrophysics Data System (ADS)

    Yaroslavsky, Ilya; Vinnichenko, Victoria; McNeill, Tyler; Novoseltseva, Anna; Perchuk, Igor; Vybornov, Alexander; Altshuler, Gregory; Gapontsev, Valentin

    2018-02-01

    Recently, a Thulium (Tm) fiber laser operating at a wavelength of 1940 nm and peak power up to 500 W has been introduced as a promising energy source for laser lithotripsy. Direct comparative studies have demonstrated considerable advantages of Tm fiber laser over the current industry-standard 2100 nm Holmium:YAG (Ho:YAG) device in terms of ablation rate and retropulsion effects. In this work, we investigated avenues of further improving stone ablation efficiency and reducing retropulsion. Specifically, the roles of temporal pulse structure and fiber tip preparation were studied in detail. Experiments were conducted on Bego stone phantoms in an aqueous environment using a computerized 2D stage for controlled scanning of the fiber over the stone surface. High-resolution 3D-enabled optical microscopy was employed to assess both fiber tip damage and stone ablation rate. Retropulsion effects were quantified using a high-speed video camera. Fiber burn back was evaluated as well. Fiber performance could be preserved during prolonged (up to 15 min) procedures when the fiber tip was adequately prepared. Furthermore, the results were compared with available literature for similar experiments performed with the Ho:YAG laser. The data obtained provide an important foundation for optimizing clinical performance of Tm fiber systems for lithotripsy.

  20. Metrological traceability of holmium oxide solution

    NASA Astrophysics Data System (ADS)

    Gonçalves, D. E. F.; Gomes, J. F. S.; Alvarenga, A. P. D.; Borges, P. P.; Araujo, T. O.

    2018-03-01

    Holmium oxide solution was prepared as a candidate of certified reference material for spectrophotometer wavelength scale calibration. Here is presented the necessary steps for evaluation of the uncertainty and the establishment of metrological traceability for the production of this material. Preliminary results from the first produced batch are shown.

  1. What Is New with Sexual Side Effects After Transurethral Male Lower Urinary Tract Symptom Surgery?

    PubMed

    Rieken, Malte; Antunes-Lopes, Tiago; Geavlete, Bogdan; Marcelissen, Tom

    2018-01-01

    Transurethral resection of the prostate as well as laser prostatectomy (by either holmium laser enucleation of the prostate or Greenlight laser vaporization) is associated with risks of sexual dysfunction such as antegrade ejaculation and occasionally erectile dysfunction. While ejaculation-sparing variations of these techniques show promising results, larger multicenter studies are needed to confirm promising data. Prostatic urethral lift maintains erectile and ejaculatory function at 5-yr follow-up. The same is true for the 3-yr data on the Rezum system. Recently, Aquablation has shown promising results; however, these 6-mo data need to be confirmed during longer follow-up. An individualized, shared decision-making process based on clinical parameters and patient preference is warranted to select the ideal treatment option for each patient. Sexual dysfunction such as loss of ejaculation and, less frequently, erectile dysfunction can occur after transurethral prostate surgery. Ejaculation-sparing modifications as well as minimally invasive alternatives show promising results. An individualized approach is warranted to select the ideal technique for each patient. Copyright © 2018 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  2. Stone/tissue differentiation during intracorporeal lithotripsy using diffuse white light reflectance spectroscopy: In vitro and clinical measurements.

    PubMed

    Lange, Birgit; Jocham, Dieter; Brinkmann, Ralf; Cordes, Jens

    2014-10-01

    Holmium laser lithotripsy is the 'gold standard' for intracorporeal fragmentation of stones. However, there is a risk of damaging and perforating the ureter wall when the laser is accidentally fired while the fiber is in contact with tissue. The aim of this study was to evaluate if white illumination light, diffusely reflected back into the treatment fiber and spectrally analyzed, can be used for differentiating between stone and tissue. Firstly, in vitro reflectance spectra (Xenon light source, wavelength range λ = 350-850 nm) of 38 human kidney stones, porcine renal calix and ureter tissue were collected. Secondly, in an in vivo study with 8 patients, 72 ureter and 49 stone reflectance signals were recorded during endourological interventions. The spectra were analyzed to discriminate between stone and tissue by the absence or presence of minima due to hemoglobin absorption at λ1  = 542nm and λ3  = 576nm. In vitro, all stone and tissue signals could correctly be identified by calculating the ratio R = I (λ1  = 542 nm)/I (λ2  = 475 nm): Because of the hemoglobin absorption at λ1 , R is smaller for tissue than for calculi. In vivo, only 75% tissue spots could correctly be identified utilizing this method. Using the more sophisticated evaluation of looking for minima in the diffuse reflectance spectra at λ1  = 542 nm and λ3  = 576 nm, 62 out of 64 tissue spots were correctly identified (sensitivity 96.9%). This was also the case for 39 out of 43 stone spots. Taking into account the number of measured spectra, a tissue detection probability of 91% and a stone detection probability of 77% was achieved (significance level 5%). White light diffusely reflected off the treatment zone into the fiber can be used to strongly improve the safety of Holmium laser lithotripsy by implementing an automatic feedback control algorithm that averts mispositioning the fiber. © 2014 Wiley Periodicals, Inc.

  3. A Single Dose of Intraoperative Antibiotics Is Sufficient to Prevent Urinary Tract Infection During Ureteroscopy.

    PubMed

    Chew, Ben H; Flannigan, Ryan; Kurtz, Michael; Gershman, Boris; Arsovska, Olga; Paterson, Ryan F; Eisner, Brian H; Lange, Dirk

    2016-01-01

    American Urology Association (AUA) Best Practice Guidelines for ureteroscopic stone treatment recommend antibiotic coverage for <24 hours following the procedure. The purpose of this study was to evaluate if the addition of postoperative antibiotics reduces urinary tract infections (UTIs) following ureteroscopic stone treatment beyond the recommended preoperative dose. A retrospective review was performed of consecutive patients at two institutions, University of British Columbia and Massachusetts General Hospital, Harvard. All patients received a single dose of antibiotics before ureteroscopic stone treatment. A subset of patients was also given postoperative antibiotics. The rate of UTI was compared in patients receiving only preoperative antibiotics (group 1) vs those who received pre- and postoperative antibiotics (group 2). Eighty-one patients underwent ureteroscopy for renal calculi. Mean time to follow up was 42 ± 88 days. Eight (9.9%) patients in total (two from group 1 and six from group 2, p = 0.1457) developed UTIs postoperatively. In group 1, both patients presented with pyelonephritis (n = 2); those patients with infections in group 2 presented with urosepsis (n = 2) and cystitis (n = 2) and two patients had asymptomatic bacteriuria. Risk factors such as preoperative stenting, nephrostomy tubes, and foley catheters neither differed between groups nor did they predispose patients to postoperative infections. The postoperative UTI rate in this study (9.9%) is consistent with previous reports. Our data suggest that a single preoperative dose of antibiotics is sufficient, and additional postoperative antibiotics do not decrease infection rates after ureteroscopic stone treatment. Risk for selection bias is a potential limitation.

  4. Safety and efficacy of silodosin and tadalafil in ease of negotiation of large ureteroscope in the management of ureteral stone: A prosective randomized trial

    PubMed Central

    Bhattar, Rohit; Jain, Vipin; Tomar, Vinay; Yadav, Sher Singh

    2017-01-01

    Objective To evaluate the safety and efficacy of silodosin and tadalafil in ease of negotiation of large size ureteroscope (8/9.8 Fr) in the management of ureteral stone. Material and methods Between June 2015 and May 2016, 86 patients presented with ureteral stone of size 6–15 mm were on consent randomly assigned to 1 of 3 outpatient treatment arms: silodosin (Group A), tadalafil (Group B), and placebo (Group C). After two weeks of therapy 67 patients underwent ureteroscopy, and ureteral orifice configuration, ureteroscopic negotiation, ureteral dilatation, operating time, procedural complication and drug related side effects were noted in each group. Results Ureteral negotiation was significantly better in Groups A (73.9%) and B (69.6%) as compared to Group C (38.1%) (p<0.01). Statistically significant difference was noted in the requirement for dilatation in Group C (71.4%) as compared to Groups A (26.1%) and B (39.1%) (p<0.01). Ureteral orifice was found to be more dilated in Groups A (69.6%) and B (60.9%) as compared to Group C (28.6%). Mean operating time was statistically lower in Groups A (35.2 min) and B (34.91 min) as compared to Group C (41.14 min) (p<0.01). Conclusion Both silodosin and tadalafil not only relax ureteral smooth muscle but also help in forward propagation of large size ureteroscope (8/9.8 Fr) without any significant risk of adverse events. PMID:29201512

  5. The effect of nonablative laser energy on joint capsular properties. An in vitro histologic and biochemical study using a rabbit model

    NASA Technical Reports Server (NTRS)

    Hayashi, K.; Thabit, G. 3rd; Vailas, A. C.; Bogdanske, J. J.; Cooley, A. J.; Markel, M. D.

    1996-01-01

    The purpose of this study was to evaluate the effect of laser energy at nonablative levels on joint capsular histologic and biochemical properties in an in vitro rabbit model. The medial and lateral portions of the femoropatellar joint capsule from both stifles of 12 mature New Zealand White rabbits were used. Specimens were divided into three treatment groups (5 watts, 10 watts, and 15 watt) and one control group using a randomized block design. Specimens were placed in a 37 degrees bath of lactated Ringer's solution and laser energy was applied using a holmium:yttrium-aluminum-garnet laser in four transverse passes across the tissue at a velocity of 2 mm/sec with the handpiece set 1.5 mm from the synovial surface. Histologic analysis revealed thermal alteration of collagen (fusion) and fibroblasts (pyknosis) at all energy densities, with higher laser energy causing significantly greater morphologic changes over a larger area (P < 0.05). Application of laser energy did not significantly alter the biochemical parameters evaluated, including type I collagen content and nonreducible crosslinks (P > 0.05). This study demonstrated that nonablative laser energy caused significant thermal damage to the joint capsular tissue in an energy-dependent fashion, but type I collagen content and nonreducible crosslinks (P > 0.05). This study demonstrated that nonablative laser energy caused significant thermal damage to the joint capsular tissue in an energy-dependent fashion, but type I Collagen content and nonreducible corsslinks were not significantly altered.

  6. Adverse events resulting from lasers used in urology.

    PubMed

    Althunayan, Abdulaziz M; Elkoushy, Mohamed A; Elhilali, Mostafa M; Andonian, Sero

    2014-02-01

    To collate world reports of adverse events (AEs) resulting from lasers used in urology. The Manufacturer and User Facility Device Experience (MAUDE) database of the United States Food and Drug Administration (FDA) was searched using the term "Laser for gastro-urology use." In addition, the Rockwell Laser Industries (RLI) Laser Accident Database was searched for the following types of lasers: neodymium-doped yttrium aluminum garnet (Nd:YAG), holmium:yttrium aluminum garnet (Ho:YAG), potassium titanyl phosphate (KTP), diode and thulium:YAG (Tm:YAG). Both databases were last accessed on October 1, 2012. Overall, there were 433 AEs; 166 in MAUDE database (1992-2012) and 267 in RLI database (1964-2005). Most of the AEs (198/433 or 46%) resulted from generator failure or fiber tip breaking. Whereas there were 20 (4.6%) AEs harming medical operators, there were 159 (37%) AEs harming nonmedical operators using Nd:YAG, KTP, and diode lasers. Eye injuries ranging from mild corneal abrasions to total vision loss were reported in 164 AEs with the use of Nd:YAG, KTP, and diode lasers. Overall, there were 36 (8.3%) AEs resulting in patient harm, including 7 (1.6%) mortalities, 3 deaths from ureteral perforation using the Ho:YAG laser, and 4 deaths from air emboli using the Nd:YAG laser. Other reported patient injuries included bladder perforation resulting in urinary diversion in a patient, in addition to minor skin burns, internal burns, and bleeding in others. There were no AEs reported with the use of Tm:YAG laser. Most of the AEs reported relate to equipment failure. There were no eye injuries reported with the use of Ho:YAG lasers. Caution must be exercised when using lasers in urology, including wearing appropriate eye protection when using Nd:YAG, KTP, and diode lasers.

  7. High-pulse-energy 3.9-μm lasers in Ho:BYF

    NASA Astrophysics Data System (ADS)

    Stutz, Russell; Miller, Harold C.; Dinndorf, Kenneth M.; Cassanho, Arlete; Jenssen, Hans P.

    2004-07-01

    Experimental results describing pulsed lasers operating near 3.9 μm on the Ho3+ (5I5-5I6) transition in highly-doped (> 10 at. %) barium yttrium fluoride (BaY2F8 or BYF) will be presented. The 5I5 manifolds in Ho:BYF were pumped using a flashlamp excited, free-running Cr:LiSAF laser tuned to the Ho3+ absorption peak near 889nm. Ho3+ concentrations of 10%, 20%, 30% and 40% in BYF were lased in a simple end-pumped resonator. Some similar data was also obtained in 10% and 20% Ho:YLF. The highest 3.9 μm pulse energy obtained in the comparative study was 55 mJ (at ~10% optical-to-optical efficiency) using the 30% Ho:BYF crystal. A dual end-pumped laser in 30% Ho:BYF was also demonstrated, providing a pulse energy of 90 mJ in a near diffraction limited beam (M2 ~ 1.2). Emission decay data was taken to shed light on the observed dependence of laser efficiency on holmium concentration and excitation density. The lifetimes of both lasing levels (5I5 and 5I6) deviate rather significantly from their low-concentration values. Plausible energy transfer processes that may be responsible for the observed trends in the laser and emission data will also be discussed.

  8. High-Frequency Dusting Versus Conventional Holmium Laser Lithotripsy for Intrarenal and Ureteral Calculi.

    PubMed

    Li, Roger; Ruckle, David; Keheila, Mohamed; Maldonado, Jonathan; Lightfoot, Michelle; Alsyouf, Muhannad; Yeo, Alexander; Abourbih, Samuel R; Olgin, Gaudencio; Arenas, Javier L; Baldwin, D Duane

    2017-03-01

    The efficiency of holmium laser lithotripsy for urolithiasis depends upon several factors, including laser pulse energy and frequency and stone composition and retropulsion. This study investigates the complex interplay between these factors and quantifies lithotripsy efficiency using different laser settings in a benchtop kidney and ureter model. In vitro caliceal and ex vivo porcine ureteral models were constructed. Calcium oxalate monohydrate stones were fragmented using a 200-μm laser fiber. In the caliceal model, stone fragmentation and vaporization rates at settings of 0.6 J/5 Hz, 0.2 J/15 Hz, and 0.2 J/50 Hz were compared. In the ureteral model, fragmentation time, retropulsion rate, fragmentation rate, and fragmented stone weight were compared at settings of 0.6 J/5 Hz and 0.2 J/15 Hz. Retropulsive forces generated at 0.6 J/5 Hz, 0.2 J/15 Hz, and 0.2 J/50 Hz settings were compared. Analysis was performed using Student's t-test and one-way ANOVA. In the caliceal model, the 0.6 J/5 Hz setting fragmented and vaporized stones at a higher rate than the 0.2 J/15 Hz setting (0.072 vs. 0.049 mg/s; p < 0.001). However, when the 0.2 J energy setting was combined with the 50 Hz frequency, the fragmentation rate (0.069 mg/s) was similar to the fragmentation rate at 0.6 J/5 Hz (0.072 mg/s; p = 0.677). In the ureteral model, the 0.6 J/5 Hz setting produced higher fragmentation rates (0.089 vs. 0.049 mg/s; p < 0.001), but resulted in significantly lower fragmented stone weight overall (16.815 vs. 25.485 mg; p = 0.009) due to higher retropulsion rates (0.732 vs. 0.213 mm/s; p < 0.001). Retropulsive forces decreased significantly when pulse energy decreased from 0.6 to 0.2 J (0.907 vs. 0.223 N; p < 0.001). Frequency did not affect retropulsive force at 15 and 50 Hz settings (0.223 vs. 0.288 N; p = 0.509). Laser lithotripsy of calcium oxalate monohydrate stones in the ureter should be performed using the low-energy, moderate-frequency dusting setting to minimize retropulsion and maximize efficiency. In the renal calix, the low-energy high-frequency setting performed similarly to the high-energy low-frequency setting.

  9. Emission characteristics of holmium ions in fluoro-phosphate glasses for photonic applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Babu, S.; Ratnakaram, Y. C., E-mail: ratnakaramsvu@gmail.com

    2016-05-23

    Optical properties of Ho{sup 3+} doped different fluorophosphate (FP) glasses have been synthesized and discussed. Thermal properties have been studied through differential scanning calorimetry (DSC).The Judd-Ofelt (J-O) intensity parameters Ω{sub λ} (λ= 2, 4, 6) from absorption spectra have been evaluated. Various radiative parameters have been obtained for the different excited states using J-O theory. From the emission spectra, different laser properties have been studied and discussed. The nature of decay curve analysis was performed for the {sup 5}F{sub 4}({sup 5}S{sub 2}) level. These glasses are expected to give interesting application in the field of photonic applications.

  10. In vitro comparison of renal stone laser treatment using fragmentation and popcorn technique.

    PubMed

    Klaver, Paul; de Boorder, Tjeerd; Rem, Alex I; Lock, Tycho M T W; Noordmans, Herke Jan

    2017-09-01

    To study the effectiveness of two laser techniques clinically used to fragment renal stones: fragmenting technique (FT) and popcorn technique (PT). Phantom stones were placed in a test tube filled with water, mimicking a renal calyx model. A Holmium:YAG laser was used for fragmentation using both techniques. Four series of experiments were performed with two parameters: the technique (FT or PT) and the number of stones in the test tube (one or four). The mass decrease of the phantom stones was measured before, during, and after the experiment to quantify the effect of both techniques. Visualization of PT showed that the main effect of PT takes place, when the stone moves in front of the laser fiber and is subject to direct radiant exposure. Both FT and PT resulted in a decrease in stone weight; the mass decrease of the stones subjected to FT exceeded that of the stones subjected to PT, even with less laser energy applied. This difference in mass decrease was evident in both the experiments with one and four stones. PT was less effective in decreasing stone weight compared with FT. The FT is more effective regarding the applied energy than PT, even in a shorter time period and regardless of the number of stones. This study suggests that FT is to be preferred over PT, when stones are accessible by the laser fiber. Lasers Surg. Med. 49:698-704, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. Performance of Single-Use FlexorVue vs Reusable BoaVision Ureteroscope for Visualization of Calices and Stone Extraction in an Artificial Kidney Model.

    PubMed

    Schlager, Daniel; Hein, Simon; Obaid, Moaaz Abdulghani; Wilhelm, Konrad; Miernik, Arkadiusz; Schoenthaler, Martin

    2017-11-01

    To evaluate and compare Flexor ® Vue™, a semidisposable endoscopic deflection system with disposable ureteral sheath and reusable visualization source, and a nondisposable fiber optic ureteroscope in a standard in vitro setting. FlexorVue and a reusable fiber optic flexible ureteroscope were each tested in an artificial kidney model. The experimental setup included the visualization of colored pearls and the extraction of calculi with two different extraction devices (NCircle ® and NGage ® ). The procedures were performed by six experienced surgeons. Visualization time, access to calices, successful stone retraction, and time required were recorded. In addition, the surgeons' workload and subjective performance were determined according to the National Aeronautics and Space Administration-task load index (NASA-TLX). We referred to the Likert scale to assess maneuverability, handling, and image quality. Nearly all calices (99%) were correctly identified using the reusable scope, indicating full kidney access, whereas 74% of the calices were visualized using FlexorVue, of which 81% were correctly identified. Access to the lower poles of the kidney model was significantly less likely with the disposable device, and time to completion was significantly longer (755 s vs 153 s, p < 0.001). The stone clearance success rate with the disposable device was 23% using the NGage and 13% using the NCircle basket. Overall NASA-TLX scores were significantly higher using FlexorVue. The conventional reusable device also demonstrated superior maneuverability, handling, and image quality. FlexorVue offers a semidisposable deflecting endoscopic system allowing basic ureteroscopic and cystoscopic procedures. For its use as an addition or replacement for current reusable scopes, it requires substantial technical improvements.

  12. Ureterorenoscopy with Stenting and Its Effect on Female Sexual Function.

    PubMed

    Akdeniz, Ekrem; Bolat, Mustafa Suat

    2017-05-23

    Various etiological factors have been studied which negatively affect female sexual function, but theeffects of ureteroscopic stone surgery on women's sexual dysfunction remain unknown. The aim of this study wasto investigate the effect of ureteroscopic stone surgery with postoperative stenting on female sexual function. This study included 30 sexually active female patients who underwent ureteroscopicstone surgery with JJ stenting (study group) and 26 age-matched female patients with ureteral stone surgerywithout JJ stenting (control group). Sexual function was assessed at preoperative and at the first and 3rd monthspostoperative using the Female Sexual Function Index. Overall satisfaction in relation to the age, operation time,presence of stents, body mass index, educational status, previous operations, income status, and psychogenic statuswas evaluated. Sexual function was adversely affected by ureteroscopic stone surgery with JJ stenting; but psychogenic,educational and income status remained stable. Mean individual female sexual function subscores were statistically significant between the study and control groups, but the differences in the mean Beck scores minimally improved between the two groups at preoperative (p = 0.19) visit, whereas first month (p = 0.08) and third month (p = 0.31) of postoperative controls were deteriorated but the differences were not statistically significant, respectively. Ureterorenoscopy with JJ stenting has considerably negative effects on female sexual function. JJ stenting causes temporary sexual deterioration in women and it generally ceases at the end of the 3rd month after ureteroscopic surgery. Therefore, JJ stenting should be avoided or used for as short a time as possible. If JJ stenting is inevitable, patients should be warned about a temporary decline in their sexual function during the first month of the operation that resolves at most in three months.

  13. Outcomes of flexible ureterorenoscopy and laser fragmentation for renal stones: comparison between digital and conventional ureteroscope.

    PubMed

    Somani, Bhaskar K; Al-Qahtani, Saeed M; de Medina, Sixtina Diez Gil; Traxer, Olivier

    2013-11-01

    To compare the outcomes of flexible ureterorenoscopy and lasertripsy (FURS) using digital and conventional FURS for kidney stones. From September 2007 to April 2011, 118 patients underwent FURS (by the same surgeon). The outcomes were compared between equal numbers of procedures (59 each) using a conventional flexible ureterorenoscope (C-FURS; Olympus URF-P5) and a digital flexible ureterorenoscope (D-FURS; Olympus URF-V). Although the deflection, working channel, and field view are similar in both, the initial and terminal diameter is 8.4F and 9.9F and 6.9F and 8.4F for the D-FURS and C-FURS, respectively. The mean stone fragmentation time was calculated by the size per operative time. The preoperative, operative, and postoperative data were retrospectively analyzed and compared. The patient demographics were comparable. The mean stone size was 12.8 and 12 mm in the C-FURS and D-FURS groups, respectively. The initial assessment of the entire pyelocaliceal system was possible in 58 of 59 cases (98%) in the C-FURS group and 56 of 59 cases (94%) in the D-FURS group. The mean operative time was significantly longer in the C-FURS group (53.8 ± 15.2 minutes vs 44.5 ± 14.9 minutes). The overall stone-free rate 1 month after the procedure was 86% in the C-FURS group and 88% in the D-FURS group. Although on comparison, the D-FURS had slightly limited maneuverability, comparable success rates can be achieved with both conventional and digital ureteroscopes. D-FURSs significantly reduced the operative time compared with C-FURSs. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Comparison of cold-knife optical internal urethrotomy and holmium:YAG laser internal urethrotomy in bulbar urethral strictures

    PubMed Central

    Yenice, Mustafa Gurkan; Sam, Emre; Colakoglu, Yunus; Atar, Feyzi Arda; Sahin, Selcuk; Simsek, Abdulmuttalip; Tugcu, Volkan

    2017-01-01

    Introduction To compare the results of cold-knife optical internal urethrotomy (OIU) and Holmium:YAG laser internal urethrotomy (HIU) in primary bulbar urethral strictures. Material and methods A total of 63 patients diagnosed with primary bulbar urethral stricture between August 2014 and September 2015 were assigned to the OIU (n = 29) and HIU (n = 34) groups. The demographic variables, biochemistry panels, and preoperative and postoperative uroflowmetry results including the maximum flow rate (Qmax) and mean flow rate (Qmean) values, retrograde urethrography, and diagnostic flexible urethroscopy findings were recorded prospectively. Demographic features and preoperative values were not statistically different between groups (p >0.05). Mean surgical times were 18.4 ±2.3 min for OIU and 21.9 ±3.8 min for HIU groups, which was statistically significant (p <0.05). There was no significant difference in complication rates in both groups (p = 0.618). Results Postoperative Qmax values were increased in both groups even though postoperative Qmax values were not significantly different between the two groups in the short- and long-term results at 3, 6, and 12 months (p >0.05). There was no recurrence in the first 3 months in either group. The urethral stricture recurrence rate up to month 12 was not statistically significant for the OIU group (n = 6, 20.7%) as compared to the HIU group (n = 11, 32.4%; p = 0.299). At follow-up, the SFR and IFR was 96% and 88% at 3-months, and 82% and 71% at 12-months, respectively (p <0.001). While almost three-quarters of patients were stone and infection free at 12-months, the majority of those with stones recurrence also had recurrence of their UTI. Conclusions HIU is an alternative method to OIU, and it has similar success rates in the treatment of short segment bulbar urethral strictures. PMID:29732217

  15. Comparison of Predictive Factors for Postoperative Incontinence of Holmium Laser Enucleation of the Prostate by the Surgeons' Experience During Learning Curve.

    PubMed

    Shigemura, Katsumi; Tanaka, Kazushi; Yamamichi, Fukashi; Chiba, Koji; Fujisawa, Masato

    2016-03-01

    To detect predictive factors for postoperative incontinence following holmium laser enucleation of the prostate (HoLEP) according to surgeon experience (beginner or experienced) and preoperative clinical data. Of 224 patients, a total of 203 with available data on incontinence were investigated. The potential predictive factors for post-HoLEP incontinence included clinical factors, such as patient age, and preoperative urodynamic study results, including detrusor overactivity (DO). We also classified the surgeons performing the procedure according to their HoLEP experience: beginner (<21 cases) and experienced (≥21 cases). Our statistical data showed DO was a significant predictive factor at the super-short period (the next day of catheter removal: odds ratio [OR], 3.375; P=0.000). Additionally, patient age, surgeon mentorship (inverse correlation), and prostate volume were significant predictive factors at the 1-month interval after HoLEP (OR, 1.072; P=0.004; OR, 0.251; P=0.002; and OR, 1.008; P=0.049, respectively). With regards to surgeon experience, DO and preoperative International Prostate Symptom Score (inverse) at the super-short period, and patient age and mentorship (inverse correlation) at the 1-month interval after HoLEP (OR, 3.952; P=0.002; OR, 1.084; P=0.015; and OR,1.084; P=0.015; OR, 0.358; P=0.003, respectively) were significant predictive factors for beginners, and first desire to void (FDV) at 1 month after HoLEP (OR, 1.009; P=0.012) was a significant predictive factor for experienced surgeons in multivariate analysis. Preoperative DO, IPSS, patient age, and surgeon mentorship were significant predictive factors of postoperative patient incontinence for beginner surgeons, while FDV was a significant predictive factors for experienced surgeons. These findings should be taken into account by surgeons performing HoLEP to maximize the patient's quality of life with regards to urinary continence.

  16. Holmium laser enucleation of the prostate for treatment for large-sized benign prostate hyperplasia; is it a realistic endourologic alternative in developing country?

    PubMed

    Elshal, Ahmed M; Mekkawy, Ramy; Laymon, Mahmoud; Barakat, Tamer S; Elsaadany, Mohamed M; El-Assmy, Ahmed; El-Nahas, Ahmed R

    2016-03-01

    To assess the functional outcome and cumulative health-resource-related cost of holmium laser enucleation of the prostate (HoLEP) in comparison with transvesical open prostatectomy (TVOP) in a developing country. Matching of 92 HoLEP and 91 TVOP procedures was performed using resected prostate tissue weight as a sole matching criterion. Safety, efficacy, and accordingly health-related cost-efficiency of both procedures were statistically compared. Preoperative criteria and mean prostate size (166.7 ± 49.7, 161.4 ± 35.7 ml) were similar in HoLEP and TVOP, respectively; however, HoLEP treated more comorbid patients. Blood transfusion was 2.1 and 26.1 % after HoLEP and TVOP, respectively (P = 0.001). Median time to catheter removal and hospital stay was 2 days after HoLEP and 5 and 9 days, respectively, after TVOP (P < 0.001). On modified Clavien scale, grade per grade, there was no statistically significant difference between the two groups apart from local wound complications in TVOP group. High-grade complications (≥ grade 3) were reported in 3.2 and 6.5 % in HoLEP and TVOP, respectively (P = 0.49). Resected prostate tissue weight was independently associated with high-grade periprocedure complications (OR[95 %CI] 1.22[1.02:1.49], P = 0.03). Last follow-up symptom score, peak urine flow rate, residual urine, % PSA reduction, and need for reoperation were comparable between the two groups. HoLEP costs the hospital in the first 3 months 4111.8EP (575US$) versus 4305.4EP (602US$) for TVOP (P = 0.09). In high-volume hospital, HoLEP procedure seems to be equally safe and effective as TVOP with the advantages of minimally invasive procedures. Two years after adopting the technique, HoLEP equally costs the hospital as TVOP. Significant hospital cost savings are anticipated in subsequent cases.

  17. Femtosecond laser lithotripsy: feasibility and ablation mechanism.

    PubMed

    Qiu, Jinze; Teichman, Joel M H; Wang, Tianyi; Neev, Joseph; Glickman, Randolph D; Chan, Kin Foong; Milner, Thomas E

    2010-01-01

    Light emitted from a femtosecond laser is capable of plasma-induced ablation of various materials. We tested the feasibility of utilizing femtosecond-pulsed laser radiation (lambda=800 nm, 140 fs, 0.9 mJ/pulse) for ablation of urinary calculi. Ablation craters were observed in human calculi of greater than 90% calcium oxalate monohydrate (COM), cystine (CYST), or magnesium ammonium phosphate hexahydrate (MAPH). Largest crater volumes were achieved on CYST stones, among the most difficult stones to fragment using Holmium:YAG (Ho:YAG) lithotripsy. Diameter of debris was characterized using optical microscopy and found to be less than 20 microm, substantially smaller than that produced by long-pulsed Ho:YAG ablation. Stone retropulsion, monitored by a high-speed camera system with a spatial resolution of 15 microm, was negligible for stones with mass as small as 0.06 g. Peak shock wave pressures were less than 2 bars, measured by a polyvinylidene fluoride (PVDF) needle hydrophone. Ablation dynamics were visualized and characterized with pump-probe imaging and fast flash photography and correlated to shock wave pressures. Because femtosecond-pulsed laser ablates urinary calculi of soft and hard compositions, with micron-sized debris, negligible stone retropulsion, and small shock wave pressures, we conclude that the approach is a promising candidate technique for lithotripsy.

  18. WIND MEASUREMENTS WITH HIGH-ENERGY DOPPLER LIDAR

    NASA Technical Reports Server (NTRS)

    Koch, Grady J.; Kavaya, Michael J.; Barnes, Bruce W.; Beyon, Jeffrey Y.; Petros, Mulugeta; Jirong, Yu; Amzajerdian, Farzin; Slingh, Upendra N.

    2006-01-01

    Coherent lidars at 2-micron wavelengths from holmium or thulium solid-state lasers have been in use to measure wind for applications in meteorology, aircraft wake vortex tracking, and turbulence detection [1,2,3] These field-deployed lidars, however, have generally been of a pulse energy of a few millijoules, limiting their range capability or restricting operation to regions of high aerosol concentration such as the atmospheric boundary layer. Technology improvements in the form of high-energy pulsed lasers, low noise detectors, and high optical quality telescopes are being evaluated to make wind measurements to long ranges or low aerosol concentrations. This research is aimed at developing lidar technology for satellite-based observation of wind on a global scale. The VALIDAR project was initiated to demonstrate a high pulse energy coherent Doppler lidar. VALIDAR gets its name from the concept of validation lidar, in that it can serve as a calibration and validation source for future airborne and spaceborne lidar missions. VALIDAR is housed within a mobile trailer for field measurements.

  19. Rapid vaporization of kidney stones, ex vivo, using a Thulium fiber laser at pulse rates up to 500 Hz with a stone basket

    NASA Astrophysics Data System (ADS)

    Hardy, Luke A.; Wilson, Christopher R.; Irby, Pierce B.; Fried, Nathaniel M.

    2014-03-01

    The Holmium:YAG laser (λ = 2120 nm) is currently the preferred laser for fragmenting kidney stones in the clinic. However, this laser has some limitations, including operation at low pulse rates and a multimode spatial beam profile which prohibits its use with smaller, more flexible optical fibers. Our laboratory is studying the Thulium fiber laser (λ = 1908 nm) as an alternative lithotripter. The TFL has several advantages, including lower stone ablation thresholds, use with smaller and more flexible fibers, and operation at arbitrary pulse lengths and pulse rates. Previous studies have reported increased stone ablation rates with TFL operation at higher pulse rates, however, stone retropulsion remains an obstacle to even more efficient stone ablation. This study explores TFL operation at high pulse rates in combination with a stone stabilization device (e.g. stone basket) for improved efficiency. A TFL beam with pulse energy of 35 mJ, pulse duration of 500-μs, and pulse rates of 10-500 Hz was coupled into 100-μm-core, low-OH, silica fibers, in contact mode with uric acid and calcium oxalate monohydrate stones, ex vivo. TFL operation at 500 Hz produced UA and COM stone ablation rates up to 5.0 mg/s and 1.3 mg/s, respectively. High TFL pulse rates produced increased stone ablation rates sufficient for use in the clinic.

  20. Which ureteral access sheath is compatible with your flexible ureteroscope?

    PubMed

    Al-Qahtani, Saeed M; Letendre, Julien; Thomas, Alexandre; Natalin, Ricardo; Saussez, Thibaud; Traxer, Olivier

    2014-03-01

    Our aim is to evaluate different ureteral access sheaths (UASs), which are available in the international market and their compatibility with different available flexible ureteroscopes (F-URSs) to help the urologist choose the proper ureteral access sheath for his or her endoscope before commencing the procedure. A total of 21 UASs and 12 F-URSs were evaluated. Measurements were obtained in French (F) units considering different characteristics for each UAS and each F-URS. Insertion test without friction between F-URS and UAS was considered as a successful test and was referred as (YES). All UASs and F-URSs were successfully submitted to the insertion test. All F-URSs that were inserted into UASs without friction had an internal diameter of at least 12F. Different lengths of UAS did not influence the test outcome. This study was able to establish a correlation table between different UASs and different flexible ureteroscopes. As of now, the 12/14F UAS is considered the universal UAS that accepts all F-URSs that are available in the endourology field. Nevertheless, we are expecting a significant change with the new standard size 10/12F UAS as well as huge advances in minimizing the size of different endoscopes.

  1. TISU: Extracorporeal shockwave lithotripsy, as first treatment option, compared with direct progression to ureteroscopic treatment, for ureteric stones: study protocol for a randomised controlled trial.

    PubMed

    McClinton, Samuel; Cameron, Sarah; Starr, Kathryn; Thomas, Ruth; MacLennan, Graeme; McDonald, Alison; Lam, Thomas; N'Dow, James; Kilonzo, Mary; Pickard, Robert; Anson, Ken; Keeley, Frank; Burgess, Neil; Clark, Charles Terry; MacLennan, Sara; Norrie, John

    2018-05-22

    Urinary stone disease is very common with an estimated prevalence among the general population of 2-3%. Ureteric stones are associated with severe pain as they pass through the urinary tract and have significant impact on patients' quality of life due to the detrimental effect on their ability to work and need for hospitalisation. Most ureteric stones can be expected to pass spontaneously with supportive care. However, between one-fifth and one-third of cases require an intervention. The two standard active intervention options are extracorporeal shockwave lithotripsy (ESWL) and ureteroscopic stone retrieval. ESWL and ureteroscopy are effective in terms of stone clearance; however, they differ in terms of invasiveness, anaesthetic requirement, treatment setting, complications, patient-reported outcomes (e.g. pain after intervention, time off work) and cost. There is uncertainty around which is the most clinically effective in terms of stone clearance and the true cost to the NHS and to society (in terms of impact on patient-reported health and economic burden). The aim of this trial is to determine whether, in adults with ureteric stones, judged to require active intervention, ESWL is not inferior and is more cost-effective compared to ureteroscopic treatment as the initial management option. The TISU study is a pragmatic multicentre non-inferiority randomised controlled trial of ESWL as the first treatment option compared with direct progression to ureteroscopic treatment for ureteric stones. Patients aged over 16 years with a ureteric stone confirmed by non-contrast computed tomography of the kidney, ureter and bladder (CTKUB) will be randomised to either ESWL or ureteroscopy. The primary clinical outcome is resolution of the stone episode (no further intervention required to facilitate stone clearance) up to six months from randomisation. The primary economic outcome is the incremental cost per quality-adjusted life years (QALYs) gained at six months from randomisation. Determining whether ESWL is not inferior clinically and is cost-effective compared to ureteroscopic treatment as the initial management in adults with ureteric stones who are judged to require active treatment is relevant not only to patients and clinicians but also to healthcare providers, both in the UK and globally. ISRCTN registry, ISRCTN92289221 . Registered on 21 February 2013.

  2. Material science as basis for nuclear medicine: Holmium irradiation for radioisotopes production

    NASA Astrophysics Data System (ADS)

    Usman, Ahmed Rufai; Khandaker, Mayeen Uddin; Haba, Hiromitsu; Otuka, Naohiko

    2018-05-01

    Material Science, being an interdisciplinary field, plays important roles in nuclear science. These applications are seen in weaponry, armoured vehicles, accelerator structure and development, semiconductor detectors, nuclear medicine and many more. Present study presents the applications of some metals in nuclear medicine (radioisotope production). The charged-particle-induced nuclear reactions by using cyclotrons or accelerators have become a very vital feature of the modern nuclear medicine. Realising the importance of excitation functions for the efficient production of medical radionuclides, some very high purity holmium metals are generally prepared or purchased for bombardment in nuclear accelerators. In the present work, various methods to obtain pure holmium for radioisotope production have been discussed while also presenting details of our present studies. From the experimental work of the present studies, some very high purity holmium foils have been used in the work for a comprehensive study of residual radionuclides production cross-sections. The study was performed using a stacked-foil activation technique combined with γ-ray spectrometry. The stack was bombarded with 50.4 MeV alpha particle beam from AVF cyclotron of RI Beam Factory, Nishina Centre for Accelerator-Based Science, RIKEN, Japan. The work produced thulium radionuclides useful in nuclear medicine.

  3. [Research on the cytotoxic and genotoxic effects of rare-earth element holmium to Vicia faba].

    PubMed

    Qu, Ai; Wang, Cheng-Run; Bo, Jun

    2004-03-01

    Crystal of nitrate, made by the reaction of holmium trioxide and nitric acid, was dissolved in distilled water, thus diluted into gradient solution. Soaked in the solution for 6 hours (6h), the root tips of Vicia faba were then recovered and cultivated for 22 h and 24 h, respectively. By observing the change of root tips and calculating the frequency of micronucleus (FMN), the frequency of chromosomal aberrations(CAF) and mitosis index (MI),we find that the dosage below 4mg/L (expressed by concentration of holmium trioxide) could accelerate the growth of root tips of Vicia faba. CAF and FMN increased while MI decreased with the rise of concentrations. From it a dosage effect relationship is clearly seen. And it indicated that the rare earth element holmium has certain cytotoxic and genotoxic effects. Furthermore, the different recovery groups have different FMN, CAF and MI, and the difference lies in the fact that FMN of 22 h recovery group was lower than that of 24 h recovery group, while CAF and MI were higher than those of 24 h recovery group. The results suggest that the statistics of FMN should be made after that of CAF.

  4. Examination of the Mass Transfer of Additive Elements in Barium Titanate Ceramics during Sintering Process by Laser Ablation ICP-MS.

    PubMed

    Sakate, Daisuke; Iwazaki, Yoshiki; Kon, Yoshiaki; Yokoyama, Takaomi; Ohata, Masaki

    2018-01-01

    The mass transfer of additive elements during the sintering of barium titanate (BaTiO 3 ) ceramic was examined by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) in the present study. An analytical sample consisting of two pellets of BaTiO 3 with different concentrations of additive elements of manganese (Mn) and holmium (Ho) as well as silicon (Si) as a sintering reagent was prepared and measured by LA-ICP-MS with small laser irradiated diameter of 10 μm to evaluate the distributions and concentrations of additive elements in order to examine their mass transfers. As results, enrichments of Mn and Si as an additive element and a sintering reagent, respectively, were observed on the adhesive surface between two BaTiO 3 pellets, even though Ho did not show a similar phenomenon. The mass transfers of additive elements of Mn and Ho were also examined, and Mn seemed to show a larger mass transfer than that of Ho during the sintering process for BaTiO 3 ceramics. The results obtained in this study shows the effectives of LA-ICP-MS for the future improvement of MLCCs.

  5. A pilot study to determine medical laser generated air contaminant emission rates for a simulated surgical procedure.

    PubMed

    Lippert, Julia F; Lacey, Steven E; Lopez, Ramon; Franke, John; Conroy, Lorraine; Breskey, John; Esmen, Nurtan; Liu, Li

    2014-01-01

    The U.S. Occupational Safety and Health Administration (OSHA) estimates that half a million health-care workers are exposed to laser surgical smoke each year. The purpose of this study was to establish a methodology to (1) estimate emission rates of laser-generated air contaminants (LGACs) using an emission chamber, and to (2) perform a screening study to differentiate the effects of three laser operational parameters. An emission chamber was designed, fabricated, and assessed for performance to estimate the emission rates of gases and particles associated with LGACs during a simulated surgical procedure. Two medical lasers (Holmium Yttrium Aluminum Garnet [Ho:YAG] and carbon dioxide [CO2]) were set to a range of plausible medical laser operational parameters in a simulated surgery to pyrolyze porcine skin generating plume in the emission chamber. Power, pulse repetition frequency (PRF), and beam diameter were evaluated to determine the effect of each operational parameter on emission rate using a fractional factorial design. The plume was sampled for particulate matter and seven gas phase combustion byproduct contaminants (benzene, ethylbenzene, toluene, formaldehyde, hydrogen cyanide, carbon dioxide, and carbon monoxide): the gas phase emission results are presented here. Most of the measured concentrations of gas phase contaminants were below their limit of detection (LOD), but detectable measurements enabled us to determine laser operation parameter influence on CO2 emissions. Confined to the experimental conditions of this screening study, results indicated that beam diameter was statistically significantly influential and power was marginally statistically significant to emission rates of CO2 when using the Ho:YAG laser but not with the carbon dioxide laser; PRF was not influential vis-a-vis emission rates of these gas phase contaminants.

  6. Local shock-wave lithotripsy of distal ureteral calculi.

    PubMed

    Voges, G E; Wilbert, D M; Stöckle, M; Hohenfellner, R

    1988-01-01

    Since the initiation of the clinical trial utilizing a second-generation lithotripor (Lithostar, Siemens, Erlangen, FRG), 96 patients with distal ureteral calculi (i.e. calculi below the pelvic brim) underwent local shock-wave lithotripsy. Routine treatment was conducted under intravenous sedation and light analgesia only. Complete stone disintegration was achieved in 84 patients (87.5%), 11 requiring two sessions and 1 patient, three. In 7 patients ureteroscopy became necessary after unsuccessful local shock-wave treatment. In 2 of these patients a 9-french flexible ureteroscope and the Storz Q-switched neodymium-YAG laser was used for stone disintegration. In 3 cases loop extraction and in 2 cases open surgery had to be performed for definitive stone removal. All pre- and postoperative manipulations (except open surgery) were done on the Lithostar. Local shock-wave lithotripsy is a highly successful, noninvasive, time-saving and easily applicable technique. It has become our primary approach in the treatment of distal ureteral calculi.

  7. Scanning electron microscopy of real and artificial kidney stones before and after Thulium fiber laser ablation in air and water

    NASA Astrophysics Data System (ADS)

    Hardy, Luke A.; Irby, Pierce B.; Fried, Nathaniel M.

    2018-02-01

    We investigated proposed mechanisms of laser lithotripsy, specifically for the novel, experimental Thulium fiber laser (TFL). Previous lithotripsy studies with the conventional Holmium:YAG laser noted a primary photothermal mechanism (vaporization). Our hypothesis is that an additional mechanical effect (fragmentation) occurs due to vaporization of water in stone material from high absorption of energy, called micro-explosions. The TFL irradiated calcium oxalate monohydrate (COM) and uric acid (UA) stones, as well as artificial stones (Ultracal30 and BegoStone), in air and water environments. TFL energy was varied to determine the relative effect on the ablation mechanism. Scanning electron microscopy (SEM) was used to study qualitative and characteristic changes in surface topography with correlation to presumed ablation mechanisms. Laser irradiation of stones in air produced charring and melting of the stone surface consistent with a photothermal effect and minimal fragmentation, suggesting no mechanical effect from micro-explosions. For COM stones ablated in water, there was prominent fragmentation in addition to recognized photothermal effects, supporting dual mechanisms during TFL lithotripsy. For UA stones, there were minimal photothermal effects, and dominant effects were mechanical. By increasing TFL pulse energy, a greater mechanical effect was demonstrated for both stone types. For artificial stones, there was no significant evidence of mechanical effects. TFL laser lithotripsy relies on two prominent mechanisms for stone ablation, photothermal and mechanical. Water is necessary for the mechanical effect which can be augmented by increasing pulse energy. Artificial stones may not provide a predictive model for mechanical effects during laser lithotripsy.

  8. A cost analysis of stenting in uncomplicated semirigid ureteroscopic stone removal.

    PubMed

    Seklehner, Stephan; Sievert, Karl-Dietrich; Lee, Richard; Engelhardt, Paul F; Riedl, Claus; Kunit, Thomas

    2017-05-01

    To evaluate the outcome and the costs of stenting in uncomplicated semirigid ureteroscopic stone removal. A decision tree model was created to evaluate the economic impact of routine stenting versus non-stenting strategies in uncomplicated ureteroscopy (URS). Probabilities of complications were extracted from twelve randomized controlled trials. Stone removal costs, costs for complication management, and total costs were calculated using Treeage Pro (TreeAge Pro Healthcare version 2015, Software, Inc, Williamstown Massachusetts, USA). Stone removal costs were higher in stented URS (€1512.25 vs. €1681.21, respectively). Complication management costs were higher in non-stented procedures. Both for complications treated conservatively (€189.43 vs. €109.67) and surgically (€49.26 vs. €24.83). When stone removal costs, costs for stent removal, and costs for complication management were considered, uncomplicated URS with stent placement yielded an overall cost per patient of €1889.15 compared to €1750.94 without stent placement. The incremental costs of stented URS were €138.25 per procedure. Semirigid URS with stent placement leads to higher direct procedural costs. Costs for managing URS-related complications are higher in non-stented procedures. Overall, a standard strategy of deferring routine stenting uncomplicated ureteroscopic stone removal is more cost efficient.

  9. Production of GMP-grade radioactive holmium loaded poly(L-lactic acid) microspheres for clinical application.

    PubMed

    Zielhuis, S W; Nijsen, J F W; de Roos, R; Krijger, G C; van Rijk, P P; Hennink, W E; van het Schip, A D

    2006-03-27

    Radioactive holmium-166 loaded poly(L-lactic acid) microspheres are promising systems for the treatment of liver malignancies. The microspheres are loaded with holmium acetylacetonate (HoAcAc) and prepared by a solvent evaporation method. After preparation, the microspheres (Ho-PLLA-MS) are activated by neutron irradiation in a nuclear reactor. In this paper, the aspects of the production of a (relatively) large-scale GMP batch (4 g, suitable for treatment of 5-10 patients) of Ho-PLLA-MS are described. The critical steps of the Ho-PLLA-MS production process (sieving procedure, temperature control during evaporation and raw materials) were considered and the pharmaceutical quality of the microspheres was evaluated. The pharmaceutical characteristics (residual solvents, possible bacterial contaminations and endotoxins) of the produced Ho-PLLA-MS batches were in compliance with the requirements of the European Pharmacopoeia. Moreover, neutron irradiated Ho-PLLA-MS retained their morphological integrity and the holmium remained stably associated with the microspheres; it was observed that after 270h (10 times the half-life of Ho-166) only 0.3+/-0.1% of the loading was released from the microspheres in an aqueous solution. In conclusion, Ho-PLLA-MS which are produced as described in this paper, can be clinically applied, with respect to their pharmaceutical quality.

  10. Holmium:Yttrium Aluminum Garnet Laser and Guidewires: Is There a Durability Difference Among Guidewires Against Laser Energy? An In Vitro Experimental Study.

    PubMed

    Bagbanci, Sahin

    2017-05-01

    To evaluate the durability differences between five different type of guidewires against laser energy in an in vitro experimental ureteral model. The study was performed at the Department of Urology, Medicine Faculty of Ahi Evran University. An in vitro experimental ureteral model was created for the work; a silicon ureteral model in a saline-filled container. Experiments were performed on five different type of guidewires; ZIPwire, Sensor polytetrafluoroethylene (PTFE) Nitinol guidewire, Roadrunner ® PC wire guide, Amplatz Super Stiff, and Zebra Urologic Guidewire. These guidewires were grouped from one to five, respectively. Laser fibers were contacted to the guidewire, and laser energy was fired to the premarked tip and body parts in different adjustments. The breakage of the guidewires was detected only on the flexible tip parts in group 1a, group 1b, group 2a, group 2b, group 4a, and group 4b. The body parts of the guidewires were resistant to laser energy in all groups and did not break. The breakage of the guidewires occurred after 3 J × 10 Hz (30 W) experiment. Group 1a and 1b were different from group 2a, 2b, 4a, and 4b according to Kruskal-Wallis H test. The body parts of the guidewires in all study groups were resistant to laser energy. The tip parts of Zipwire ™ , Sensor ™ PTFE Nitinol, and Amplatz Super Stiff ™ guidewire should be kept away from the surgical field when the high power settings of the laser are being used. The body parts of the guidewires can be utilized in the surgical field safely.

  11. Skin graft take and healing following 193-nm excimer, continuous-wave carbon dioxide (CO2), pulsed CO2, or pulsed holmium: YAG laser ablation of the graft bed.

    PubMed

    Green, H A; Burd, E E; Nishioka, N S; Compton, C C

    1993-08-01

    Ablative lasers have been used for cutaneous surgery for greater than two decades since they can remove skin and skin lesions bloodlessly and efficiently. Because full-thickness skin wounds created after thermal laser ablation may require skin grafting in order to heal, we have examined the effect of the residual laser-induced thermal damage in the wound bed on subsequent skin graft take and healing. In a pig model, four different pulsed and continuous-wave lasers with varying wavelengths and radiant energy exposures were used to create uniform fascial graft bed thermal damage of approximately 25, 160, 470, and 1100 microns. Meshed split-thickness skin graft take and healing on the thermally damaged fascial graft beds were examined on a gross and microscopic level on days 3 and 7, and then weekly up to 42 days. Laser-induced thermal damage on the graft bed measuring greater than 160 +/- 60 microns in depth significantly decreased skin graft take. Other deleterious effects included delayed graft revascularization, increased inflammatory cell infiltrate at the graft-wound bed interface, and accelerated formation of hypertrophied fibrous tissue within the graft bed and underlying muscle. Ablative lasers developed for cutaneous surgery should create less than 160 +/- 60 microns of residual thermal damage to permit optimal skin graft take and healing. Pulsed carbon dioxide and 193-nm excimer lasers may be valuable instruments for the removal of full-thickness skin, skin lesions, and necrotic tissue, since they create wound beds with minimal thermal damage permitting graft take comparable to that achieved with standard surgical techniques.

  12. Discordance between Ureteroscopic Biopsy and Final Pathology for Upper Tract Urothelial Carcinoma.

    PubMed

    Margolin, Ezra J; Matulay, Justin T; Li, Gen; Meng, Xiaosong; Chao, Brian; Vijay, Varun; Silver, Hayley; Clinton, Timothy N; Krabbe, Laura-Maria; Woldu, Solomon L; Singla, Nirmish; Bagrodia, Aditya; Margulis, Vitaly; Huang, William C; Bjurlin, Marc A; Shah, Ojas; Anderson, Christopher B

    2018-06-01

    We evaluated the discordance between ureteroscopic biopsy and surgical pathology findings for grading and staging upper tract urothelial carcinoma. We also sought to establish preoperative predictors of aggressive tumors. We retrospectively reviewed the records of 314 patients who underwent ureteroscopic biopsy followed by surgical management of upper tract urothelial carcinoma from 2000 to 2016 at a total of 3 institutions. Our primary outcomes were muscle invasive (pT2 or greater) disease at surgical pathology and upgrading of clinical low grade tumors to pathological high grade. At biopsy 61% of the patients had clinical high grade tumors and 21% had subepithelial connective tissue invasion (cT1+). On final pathology 79% of the patients had pathological high grade tumors and 45% had stage pT2 or greater. On multivariate analysis advanced patient age, clinical high grade and cT1+ were independently associated with pT2 or greater. The combined presence of clinical high grade and cT1+ had 86% positive predictive value for muscle invasion while the combined absence of clinical high grade and cT1+ had 80% negative predictive value. The likelihood of missing invasion on biopsy in patients with muscle invasive disease was increased when biopsy fragments were limited to 1 mm or less. Of clinical low grade cases on biopsy 51% were upgraded at surgery. The presence of positive urine cytology was associated with an increased risk of upgrading but this was not statistically significant. Clinical high grade, cT1+ on biopsy and advanced patient age are independent risk factors for muscle invasive upper tract urothelial carcinoma. There is a significant risk of upgrading in patients with clinical low grade tumors on biopsy, especially when urine cytology is positive. The predictive value of biopsy can likely be improved by more extensive ureteroscopic sampling. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. Evaluating the Ergonomics of Flexible Ureteroscopy.

    PubMed

    Ludwig, Wesley W; Lee, Gyusung; Ziemba, Justin B; Ko, Joan S; Matlaga, Brian R

    2017-10-01

    To date, the ergonomics of flexible ureteroscopy (URS) have not been well described. We performed a study to assess the biomechanical stresses on urologists performing URS and to investigate the effect of ureteroscope type on these parameters. Electromyography (EMG) was used to quantify the activation level of muscle groups involved in URS. Surface EMG electrodes (Delsys, Boston, MA) were placed on the right and left thenar, flexor carpi ulnaris (FCU), extensor carpi ulnaris (ECU), biceps, triceps, and deltoid. Three endoscopes were studied: single-use digital (Boston Scientific LithoVue), reusable digital (Karl Storz Flex-X c ), and reusable fiber-optic (Karl Storz Flex-X 2 ). Each ureteroscope was used to perform a set sequence of navigation and procedural tasks in a training model. EMG data were processed and normalized to compare the maximum voluntary contractions between muscle groups. Cumulative muscular workload (CMW) and average muscular work per second (AWS) were used for comparative analysis. For navigational tasks, CMW and AWS were greatest for the ECU, followed in descending order by right and left thenar, FCU, biceps, deltoid, and triceps. For procedural tasks, CMW and AWS were greatest for the right thenar, followed in descending order by the left thenar, ECU, FCU, triceps, biceps, and deltoid. During navigational tasks, both LithoVue and Flex-X c had lower CMWs for every muscle group than Flex-X 2 (p < 0.05). LithoVue and Flex-X c had similar AWS and both were lower than Flex-X 2 for the right thenar, ECU, biceps, and deltoid activation (p < 0.05). During procedural tasks, both LithoVue and Flex-X c had lower CMWs and AWS for right and left thenar, ECU, and biceps than Flex-X 2 (p < 0.05). This study provides the first description of EMG-measured ergonomics of URS. Both the single-use and reusable digital ureteroscopes have similar profiles, and both have significantly better ergonomic metrics than the reusable fiber-optic ureteroscope.

  14. Holmium:YAG laser lithotripsy: A dominant photothermal ablative mechanism with chemical decomposition of urinary calculi.

    PubMed

    Chan, K F; Vassar, G J; Pfefer, T J; Teichman, J M; Glickman, R D; Weintraub, S T; Welch, A J

    1999-01-01

    Evidence is presented that the fragmentation process of long-pulse Holmium:YAG (Ho:YAG) lithotripsy is governed by photothermal decomposition of the calculi rather than photomechanical or photoacoustical mechanisms as is widely thought. The clinical Ho:YAG laser lithotriptor (2.12 microm, 250 micros) operates in the free-running mode, producing pulse durations much longer than the time required for a sound wave to propagate beyond the optical penetration depth of this wavelength in water. Hence, it is unlikely that shock waves are produced during bubble formation. In addition, the vapor bubble induced by this laser is not spherical. Thus the magnitude of the pressure wave produced at cavitation collapse does not contribute significantly to lithotripsy. A fast-flash photography setup was used to capture the dynamics of urinary calculus fragmentation at various delay times following the onset of the Ho:YAG laser pulse. These images were concurrently correlated with pressure measurements obtained with a piezoelectric polyvinylidene-fluoride needle-hydrophone. Stone mass-loss measurements for ablation of urinary calculi (1) in air (dehydrated and hydrated) and in water, and (2) at pre-cooled and at room temperatures were compared. Chemical and composition analyses were performed on the ablation products of several types of Ho:YAG laser irradiated urinary calculi, including calcium oxalate monohydrate (COM), calcium hydrogen phosphate dihydrate (CHPD), magnesium ammonium phosphate hexahydrate (MAPH), cystine, and uric acid calculi. When the optical fiber was placed perpendicularly in contact with the surface of the target, fast-flash photography provided visual evidence that ablation occurred approximately 50 micros after the initiation of the Ho:YAG laser pulse (250-350 micros duration; 375-400 mJ per pulse), long before the collapse of the cavitation bubble. The measured peak acoustical pressure upon cavitation collapse was negligible (< 2 bars), indicating that photomechanical forces were not responsible for the observed fragmentation process. When the fiber was placed in parallel to the calculus surface, the pressure peaks occurring at the collapse of the cavitation were on the order of 20 bars, but no fragmentation occurred. Regardless of fiber orientation, no shock waves were recorded at the beginning of bubble formation. Ablation of COM calculi (a total of 150 J; 0.5 J per pulse at an 8-Hz repetition rate) revealed different Ho:YAG efficiencies for dehydrated calculus, hydrated calculus, and submerged calculus. COM and cystine calculi, pre-cooled at -80 degrees C and then placed in water, yielded lower mass-loss during ablation (20 J, 1.0 J per pulse) compared to the mass-loss of calculi at room temperature. Chemical analyses of the ablated calculi revealed products resulting from thermal decomposition. Calcium carbonate was found in samples composed of COM calculi; calcium pyrophosphate was found in CHPD samples; free sulfur and cysteine were discovered in samples composed of cystine samples; and cyanide was found in samples of uric acid calculi. These experimental results provide convincing evidence that long-pulse Ho:YAG laser lithotripsy causes chemical decomposition of urinary calculi as a consequence of a dominant photothermal mechanism. Copyright 1999 Wiley-Liss, Inc.

  15. A rabbit vocal fold laser scarring model for testing lamina propria tissue engineering therapies

    PubMed Central

    Mau, Ted; Du, Mindy; Xu, Chet C.

    2015-01-01

    Objectives/Hypothesis To develop a vocal fold scarring model using an ablative laser in the rabbit as a platform for testing bioengineered therapies for missing or damaged lamina propria. Study Design Prospective controlled animal study. Methods An optimal laser energy level was first determined by assessing the depths of vocal fold injury created by a Holmium:YAG laser at various energy levels on fresh cadaveric rabbit larynges. The selected energy level was then used to create controlled unilateral injuries in vocal folds of New Zealand white rabbits, with the contralateral folds serving as uninjured controls. After 4 weeks, the larynges were harvested and subjected to excised-larynx phonation with high-speed imaging and immunohistochemical staining for collagen types I and III, elastin, and hyaluronic acid (HA) with quantitative histological analysis. Results 1.8 joules produced full-thickness injury of the lamina propria without extensive muscle injury. After 4 weeks, the injured vocal folds vibrated with reduced amplitude (P = 0.036) in excised-larynx phonation compared to normal vocal folds. The injured vocal folds contained a higher relative density of collagen type I (P = 0.004), higher elastin (P = 0.022), and lower HA (P = 0.030) compared to normal controls. Collagen type III was unchanged. Conclusions With its potential for higher precision of injury, this laser vocal fold scarring model may serve as an alternative to scarring produced by cold instruments for studying the effects of vocal fold lamina propria bioengineered therapies. Level of Evidence N/A. PMID:24715695

  16. Fine- and hyperfine structure investigations of the even-parity configuration system of the atomic holmium

    NASA Astrophysics Data System (ADS)

    Stefanska, D.; Ruczkowski, J.; Elantkowska, M.; Furmann, B.

    2018-04-01

    In this work new experimental results concerning the hyperfine structure (hfs) for the even-parity level system of the holmium atom (Ho I) were obtained; additionally, hfs data obtained recently as a by-product in investigations of the odd-parity level system were summarized. In the present work the values of the magnetic dipole and the electric quadrupole hfs constants A and B were determined for 24 even-parity levels, for 14 of them for the first time. On the basis of these results, as well as on available literature data, a parametric study of the fine structure and the hyperfine structure for the even-parity configurations of atomic holmium was performed. A multi-configuration fit of 7 configurations was carried out, taking into account second-order of the perturbation theory. For unknown electronic levels predicted values of the level energies and hfs constants are given, which can facilitate further experimental investigations.

  17. The impact of minimally invasive surgeries for the treatment of symptomatic benign prostatic hyperplasia on male sexual function: a systematic review.

    PubMed

    Frieben, Ryan W; Lin, Hao-Cheng; Hinh, Peter P; Berardinelli, Francesco; Canfield, Steven E; Wang, Run

    2010-07-01

    A systematic review of randomized controlled trials and cohort studies was conducted to evaluate data for the effects of minimally invasive procedures for treatment of symptomatic benign prostatic hyperplasia (BPH) on male sexual function. The studies searched were trials that enrolled men with symptomatic BPH who were treated with laser surgeries, transurethral microwave therapy (TUMT), transurethral needle ablation of the prostate (TUNA), transurethral ethanol ablation of the prostate (TEAP) and high-intensity frequency ultrasound (HIFU), in comparison with traditional transurethral resection of the prostate (TURP) or sham operations. A total of 72 studies were identified, of which 33 met the inclusion criteria. Of the 33 studies, 21 were concerned with laser surgeries, six with TUMT, four with TUNA and two with TEAP containing information regarding male sexual function. No study is available regarding the effect of HIFU for BPH on male sexual function. Our analysis shows that minimally invasive surgeries for BPH have comparable effects to those of TURP on male erectile function. Collectively, less than 15.4% or 15.2% of patients will have either decrease or increase, respectively, of erectile function after laser procedures, TUMT and TUNA. As observed with TURP, a high incidence of ejaculatory dysfunction (EjD) is common after treatment of BPH with holmium, potassium-titanyl-phosphate and thulium laser therapies (> 33.6%). TUMT, TUNA and neodymium:yttrium aluminum garnet visual laser ablation or interstitial laser coagulation for BPH has less incidence of EjD, but these procedures are considered less effective for BPH treatment when compared with TURP.

  18. The impact of minimally invasive surgeries for the treatment of symptomatic benign prostatic hyperplasia on male sexual function: a systematic review

    PubMed Central

    Frieben, Ryan W.; Lin, Hao-Cheng; Hinh, Peter P.; Berardinelli, Francesco; Canfield, Steven E.; Wang, Run

    2010-01-01

    A systematic review of randomized controlled trials and cohort studies was conducted to evaluate data for the effects of minimally invasive procedures for treatment of symptomatic benign prostatic hyperplasia (BPH) on male sexual function. The studies searched were trials that enrolled men with symptomatic BPH who were treated with laser surgeries, transurethral microwave therapy (TUMT), transurethral needle ablation of the prostate (TUNA), transurethral ethanol ablation of the prostate (TEAP) and high-intensity frequency ultrasound (HIFU), in comparison with traditional transurethral resection of the prostate (TURP) or sham operations. A total of 72 studies were identified, of which 33 met the inclusion criteria. Of the 33 studies, 21 were concerned with laser surgeries, six with TUMT, four with TUNA and two with TEAP containing information regarding male sexual function. No study is available regarding the effect of HIFU for BPH on male sexual function. Our analysis shows that minimally invasive surgeries for BPH have comparable effects to those of TURP on male erectile function. Collectively, less than 15.4% or 15.2% of patients will have either decrease or increase, respectively, of erectile function after laser procedures, TUMT and TUNA. As observed with TURP, a high incidence of ejaculatory dysfunction (EjD) is common after treatment of BPH with holmium, potassium-titanyl-phosphate and thulium laser therapies (> 33.6%). TUMT, TUNA and neodymium:yttrium aluminum garnet visual laser ablation or interstitial laser coagulation for BPH has less incidence of EjD, but these procedures are considered less effective for BPH treatment when compared with TURP. PMID:20473318

  19. Growth and lasing of single crystal YAG fibers with different Ho3+ concentrations

    NASA Astrophysics Data System (ADS)

    Bera, Subhabrata; Nie, Craig D.; Soskind, Michael G.; Li, Yuan; Harrington, James A.; Johnson, Eric G.

    2018-01-01

    A method to grow single crystal (SC) yttrium aluminum garnet (YAG) fibers with varied rare-earth ion dopant concentration has been proposed. Crystalline holmium aluminum garnet (HoAG), prepared via sol-gel process, was dip-coated on to previously grown SC YAG fibers. The HoAG coated SC YAG fiber preforms were re-grown to a smaller diameter using the laser heated pedestal growth (LHPG) technique. The final dopant concentration of the re-grown SC fiber was varied by changing the number of HoAG coatings on the preform. 120 μm diameter SC Ho:YAG fibers with four different dopant concentrations were grown. Lasing was demonstrated at 2.09 μm for these fibers. A maximum of 58.5% optical-to-optical slope efficiency was obtained.

  20. Stone Retropulsion with Ho: YAG and Tm: YAG Lasers: A Clinical Practice-Oriented Experimental Study.

    PubMed

    Kamal, Wissam; Kallidonis, Panagiotis; Koukiou, Georgia; Amanatides, Lefteris; Panagopoulos, Vasileios; Ntasiotis, Pantelis; Liatsikos, Evangelos

    2016-11-01

    To compare the retropulsion of stones with the use of holmium: yttrium aluminum garnet (Ho: YAG) laser and thulium: yttrium aluminum garnet (Tm: YAG) laser in settings that could be used in clinical practice. The experimental configuration included a glass tube set in a water bath filled with physiologic saline. Plaster of Paris stones were inserted in the tube. Tm: YAG and Ho: YAG laser systems were used along with a high-speed slow-motion camera. The lasers were activated with different settings. The displacement of the stone was measured according to a custom-made algorithm. Ho: YAG: the retropulsion of stones was the lowest with the energy setting of 0.5 J and the frequency of 20 Hz with long pulse duration. The highest retropulsion was observed in the case of 3 J, 5 Hz, and short pulse. Tm: YAG: the retropulsion of stones was the lowest with the energy setting of 1 J and the frequency of 10 Hz with either long or short pulse duration. Practically, there was no retropulsion at all. The highest retropulsion was observed in the case of 8 J, 5 Hz, and short pulse. Ho: YAG laser has a linear increase in stone retropulsion with increased pulse energy. On the other hand, the retropulsion rate was kept to the minimum with Tm: YAG as much as the energy level of 8 J. The activation of lasers with short pulse resulted in further displacement of the stone. Lower frequency with the same power setting seemed to result in further stone retropulsion. Higher power with the same frequency setting resulted in further displacement of the stone.

  1. 1.9 μm square-wave passively Q-witched mode-locked fiber laser.

    PubMed

    Ma, Wanzhuo; Wang, Tianshu; Su, Qingchao; Wang, Furen; Zhang, Jing; Wang, Chengbo; Jiang, Huilin

    2018-05-14

    We propose and demonstrate the operation of Q-switched mode-locked square-wave pulses in a thulium-holmium co-doped fiber laser. By using a nonlinear amplifying loop mirror, continuous square-wave dissipative soliton resonance pulse is obtained with 4.4 MHz repetition rate. With the increasing pump power, square-wave pulse duration can be broadened from 1.7 ns to 3.2 ns. On such basis Q-switched mode-locked operation is achieved by properly setting the pump power and the polarization controllers. The internal mode-locked pulses in Q-switched envelope still keep square-wave type. The Q-switched repetition rate can be varied from 41.6 kHz to 74 kHz by increasing pump power. The corresponding average single-pulse energy increases from 2.67 nJ to 5.2 nJ. The average peak power is also improved from 0.6 W to 1.1 W when continuous square-wave operation is changed into Q-switched mode-locked operation. It indicates that Q-switched mode-locked operation is an effective method to increase the square-wave pulse energy and peak power.

  2. Single-session ureteroscopic pneumatic lithotripsy for the management of bilateral ureteric stones.

    PubMed

    Isen, Kenan

    2012-01-01

    In nowadays there is no consensus on single-session ureteroscopic lithotripsy (URSL) for the management of bilateral ureteric stones. The aim of this study was to evaluate efficacy and safety of single-session URSL in patients with bilateral ureteric stones. 41 patients who have undergone bilateral single-session URSL were evaluted in this study. A 8/9.8 Fr Wolf semi-rigid ureteroscope was used for the procedures, and the stones were fragmented with pneumatic lithotripter. A high stone-free rate was achieved (90.2%) after single endoscopic procedure with a retreatment rate of 9.8%. The procedure was most successful for distal ureteric stones with a 96.2% stone-free rate followed by middle ureteric stones with a 81.8% stone-free rate while the least success was achieved for proximal ureteric stones with a 77.7% stone-free rate (p < 0.05). A greater stone-free rate was obtained in those with stones less than 10 mm (93.7%) than in those with stones larger than 10 mm (77.7%) (p < 0.05). Ureteral perforation occurred in only one patient (2.4%). No long-term complication was observed in any patient. Bilateral single-session URSL can be performed effectively and safely with a low complication rate in patients with bilateral ureteric stones. It can reduce the need of anaesthetics and hospital stay.

  3. Structural and Luminescent property of Holmium doped Borate Glasses

    NASA Astrophysics Data System (ADS)

    Usharani, V. L.; Eraiah, B.

    2018-02-01

    Holmium doped Lithium Lead Borate glasses of different compositions were prepared by melt quenching technique. Fourier transform infrared investigations on lithium lead borate glasses have been made to study the local order and vibrations of atoms in the glass network and it contains mainly BO3 and BO4 structural units. Photoluminescence techniques were employed to investigate the luminescent property of these glasses excited at 451nm. Blue emission have been observed from the transition 495 (5F3 → 5I8).

  4. Magnetic x-ray scattering studies of holmium using synchro- tron radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gibbs, D.; Moncton, D.E.; D'Amico, K.L.

    1985-07-08

    We present the results of magnetic x-ray scattering experiments on the rare-earth metal holmium using synchrotron radiation. Direct high-resolution measurements of the nominally incommensurate magnetic satellite reflections reveal new lock-in behavior which we explain within a simple spin-discommensuration model. As a result of magnetoelastic coupling, the spin-discommensuration array produces additional x-ray diffraction satellites. Their observation further substantiates the model and demonstrates additional advantages of synchrotron radiation for magnetic-structure studies.

  5. Accuracy of endoscopic intraoperative assessment of urologic stone size.

    PubMed

    Patel, Nishant; Chew, Ben; Knudsen, Bodo; Lipkin, Michael; Wenzler, David; Sur, Roger L

    2014-05-01

    Endoscopic treatment of renal calculi relies on surgeon assessment of residual stone fragment size for either basket removal or for the passage of fragments postoperatively. We therefore sought to determine the accuracy of endoscopic assessment of renal calculi size. Between January and May 2013, five board-certified endourologists participated in an ex vivo artificial endoscopic simulation. A total of 10 stones (pebbles) were measured (mm) by nonparticipating urologist (N.D.P.) with electronic calibers and placed into separate labeled opaque test tubes to prevent visualization of the stones through the side of the tube. Endourologists were blinded to the actual size of the stones. A flexible digital ureteroscope with a 200-μm core sized laser fiber in the working channel as a size reference was placed through the ureteroscope into the test tube to estimate the stone size (mm). Accuracy was determined by obtaining the correlation coefficient (r) and constructing an Altman-Bland plot. Endourologists tended to overestimate actual stone size by a margin of 0.05 mm. The Pearson correlation coefficient was r=0.924, with a p-value<0.01. The estimation of small stones (<4 mm) had a greater accuracy than large stones (≥4 mm), r=0.911 vs r=0.666. Altman-bland plot analysis suggests that surgeons are able to accurately estimate stone size within a range of -1.8 to +1.9 mm. This ex vivo simulation study demonstrates that endoscopic assessment is reliable when assessing stone size. On average, there was a slight tendency to overestimate stone size by 0.05 mm. Most endourologists could visually estimate stone size within 2 mm of the actual size. These findings could be generalized to state that endourologists are accurately able to intraoperatively assess residual stone fragment size to guide decision making.

  6. Characterization of calculus migration during Ho:YAG laser lithotripsy by high speed camera using suspended pendulum method

    NASA Astrophysics Data System (ADS)

    Zhang, Jian James; Rajabhandharaks, Danop; Xuan, Jason Rongwei; Chia, Ray W. J.; Hasenberg, Tom

    2014-03-01

    Calculus migration is a common problem during ureteroscopic laser lithotripsy procedure to treat urolithiasis. A conventional experimental method to characterize calculus migration utilized a hosting container (e.g. a "V" grove or a test tube). These methods, however, demonstrated large variation and poor detectability, possibly attributing to friction between the calculus and the container on which the calculus was situated. In this study, calculus migration was investigated using a pendulum model suspended under water to eliminate the aforementioned friction. A high speed camera was used to study the movement of the calculus which covered zero order (displacement), 1st order (speed) and 2nd order (acceleration). A commercialized, pulsed Ho:YAG laser at 2.1 um, 365-um core fiber, and calculus phantom (Plaster of Paris, 10×10×10mm cube) were utilized to mimic laser lithotripsy procedure. The phantom was hung on a stainless steel bar and irradiated by the laser at 0.5, 1.0 and 1.5J energy per pulse at 10Hz for 1 second (i.e., 5, 10, and 15W). Movement of the phantom was recorded by a high-speed camera with a frame rate of 10,000 FPS. Maximum displacement was 1.25+/-0.10, 3.01+/-0.52, and 4.37+/-0.58 mm for 0.5, 1, and 1.5J energy per pulse, respectively. Using the same laser power, the conventional method showed <0.5 mm total displacement. When reducing the phantom size to 5×5×5mm (1/8 in volume), the displacement was very inconsistent. The results suggested that using the pendulum model to eliminate the friction improved sensitivity and repeatability of the experiment. Detailed investigation on calculus movement and other causes of experimental variation will be conducted as a future study.

  7. Evaluation of cystoscopic-guided laser ablation of intramural ectopic ureters in female dogs.

    PubMed

    Berent, Allyson C; Weisse, Chick; Mayhew, Philipp D; Todd, Kimberly; Wright, Monika; Bagley, Demetrius

    2012-03-15

    To describe and evaluate the short- and long-term outcomes in female dogs after cystoscopic-guided laser ablation of ectopic ureters (CLA-EU). Prospective case series. 32 incontinent female dogs with intramural ectopic ureters. A diagnosis of intramural ectopic ureters was made via cystoscopy and fluoroscopy in all patients. Transurethral CLA-EU (via diode laser [n = 27] or Holmium:yttrium aluminum garnet laser [3]) was performed to relocate the ectopic ureteral orifice cranially into the urinary bladder. All vaginal anomalies were treated with the laser concurrently. Follow-up evaluation was standardized and included urinary continence scoring, serial bacteriologic culture of urine samples, and a follow-up cystoscopy 6 to 8 weeks after CLA-EU. Ectopic ureteral orifices of all dogs were initially located in the urethra. Eighteen of 30 dogs had bilateral ectopic ureters, and 12 had unilateral ectopic ureters. All dogs had other concurrent urinary anomalies. At the time of last follow-up (median, 2.7 years after CLA-EU, [range, 12 to 62 months]), 14 of 30 (47%) dogs did not require any additional treatments following CLA-EU to maintain urinary continence. For the 16 residually incontinent dogs, the addition of medical management, transurethral bulking-agent injection, or placement of a hydraulic occluder was effective in 3, 2, and 4 dogs, respectively, improving the overall urinary continence rate to 77% (23/30 dogs). One dog had evidence of polypoid cystitis at the neoureteral orifice 6 weeks after CLA-EU that was resolved at 3 months. CLA-EU provided an effective, safe, and minimally invasive alternative to surgery for intramural ectopic ureters in female dogs.

  8. Ambulatory pathway laser prostate surgery in severely ill patients--feasibility and short-term outcomes.

    PubMed

    Ingimarsson, Johann P; Herrick, Benjamin W; Yap, Ronald L

    2014-03-01

    To assess readmissions, complications, and outcomes of a rapid ambulatory discharge pathway (RADP) in high anesthetic risk patients who have undergone laser prostate surgery. Medical records of patients who underwent holmium laser ablation of the prostate between 2007 and 2012 by a single surgeon were retrospectively reviewed. Patients with American Society of Anesthesiologists category ≥3 ("severe systemic disease") were included. All patients were scheduled for a rapid ambulatory discharge pathway, which involved discharge on the day of surgery with a urethral catheter, with a voiding trial on postoperative day 3. Fifty-seven patients met the inclusion criteria. Fifty patients (88%) were successfully discharged on rapid ambulatory discharge pathway. Six patients (11%) were later readmitted for hematuria (3), urinary retention (1), or cardiac events (2). Two patients (4%) had emergency department visits for catheter-related problems. Increasing length of surgery, increasing amount of laser energy used, and a surgical indication indicative of more advanced disease were associated with postoperative hospitalization and readmissions on univariate analysis. No patient operated on for lower urinary tract symptoms was hospitalized or needed a readmission. The mean change in International Prostate Symptom Score and quality of life at 3 months were -12.5 ± 8.2 (P <.001) and -2.6 ± 1.7 (P <.001), respectively. It is safe to use a rapid ambulatory discharge pathway for laser prostatectomy in high anesthetic risk patients with good short-term outcomes, especially in men operated on for lower urinary tract symptoms. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. In vitro fragmentation efficiency of holmium: yttrium-aluminum-garnet (YAG) laser lithotripsy--a comprehensive study encompassing different frequencies, pulse energies, total power levels and laser fibre diameters.

    PubMed

    Kronenberg, Peter; Traxer, Olivier

    2014-08-01

    To assess the fragmentation (ablation) efficiency of laser lithotripsy along a wide range of pulse energies, frequencies, power settings and different laser fibres, in particular to compare high- with low-frequency lithotripsy using a dynamic and innovative testing procedure free from any human interaction bias. An automated laser fragmentation testing system was developed. The unmoving laser fibres fired at the surface of an artificial stone while the stone was moved past at a constant velocity, thus creating a fissure. The lithotripter settings were 0.2-1.2 J pulse energies, 5-40 Hz frequencies, 4-20 W power levels, and 200 and 550 μm core laser fibres. Fissure width, depth, and volume were analysed and comparisons between laser settings, fibres and ablation rates were made. Low frequency-high pulse energy (LoFr-HiPE) settings were (up to six times) more ablative than high frequency-low pulse energy (HiFr-LoPE) at the same power levels (P < 0.001), as they produced deeper (P < 0.01) and wider (P < 0.001) fissures. There were linear correlations between pulse energy and fragmentation volume, fissure width, and fissure depth (all P < 0.001). Total power did not correlate with fragmentation measurements. Laser fibre diameter did not affect fragmentation volume (P = 0.81), except at very low pulse energies (0.2 J), where the large fibre was less efficient (P = 0.015). At the same total power level, LoFr-HiPE lithotripsy was most efficient. Pulse energy was the key variable that drove fragmentation efficiency. Attention must be paid to prevent the formation of time-consuming bulky debris and adapt the lithotripter settings to one's needs. As fibre diameter did not affect fragmentation efficiency, small fibres are preferable due to better scope irrigation and manoeuvrability. © 2013 The Authors. BJU International © 2013 BJU International.

  10. [Open laser surgery on the locomotor apparatus].

    PubMed

    Gerber, B E; al-Khodairy, A T; Morscher, E; Hefti, F

    1996-02-01

    The first applications of laser in surgery of the locomotor apparatus in the early 1980s used the haemostatic properties of laser to diminish the amount of substitution of coagulation factors in haemophiliac patients. Only since the early 1990s has a device been available in corporating the pulsed holmium:YAG laser which works in a fluid medium without relevant side effects. Apart from haemostasis, the cutting function and tissue ablation, together with the thermal shrinking effect, are exploited in arthroscopy and percutaneous disc decompression. Now that the biophysical mechanisms of action have been elucidated, nothing stands in the way of the use of infrared lasers in open surgery of the locomotor apparatus in some indications. In a prospective clinical study we included 30 consecutive patients who underwent open laser surgery from November 1992 to August 1994, for the following indications: the sparing haemostatic tissue ablation was used for synovectomy or for bony resection in osteophytes and osteochondromas of different locations, an osteoid osteoma and a painful sacral hyperplasia in the presence of incomplete sacral meningomyelocele. With bleeding eliminated, the shaping was much easier. The non-ablative shrinking produced less tissue loss and a stabilizing strengthening of tissue at the margins of soft tissue resections, e.g. in jumper's knee, tennis elbow and Achilles tendon cysts. All laser functions that are useful in open surgery have also been used in sequestered disc herniations that are inaccessible a percutaneous procedure and, in spinal decompression, for remodelling of the posterior spine contour. An analgesic effect of laser limited the postoperative administration of analgesic drugs to an average of 3 days. No complications related to the laser treatment were observed. At follow-up 12-21 months after operation, 25 of the 30 patients in this heterogeneous population showed complete or near-total healing of the operated pathological finding, and a further 3 patients showed significant improvement. To what extent these very encouraging results will persist will be shown by long-term observation.

  11. An Unusual Complication of Ventriculoperitoneal Shunt: Urinary Bladder Stone Case Report and Literature Review.

    PubMed

    Xu, Songtao; Sheng, Weixin; Qiu, Yufa; Wang, Jianguo

    2016-01-01

    Ventriculoperitoneal (V-P) shunt surgery is the most common technique used for the treatment of hydrocephalus. The migration of ventriculoperitoneal shunt to the bladder is rare. Only two cases have been previously reported in the literature. We report on a 38-year-old male who had hydrocephalus and V-P shunt for 12 years. Two years ago, he found himself with recurrent urinary tract infections, haematuria and urges incontinence, and then he was diagnosed with bladder perforation and merge stones. The patient had an abdominal operation to cut off and take out the shunt catheter, as well as a transurethral holmium laser lithotripsy. Bladder perforation and stones are rare examples of complications in V-P surgical procedures. Controlling the effective length of the terminal V-P shunt and modifying it appropriately can effectively reduce these complications.

  12. Thulium Laser Treatment of Upper Urinary Tract Carcinoma: A Multi-Institutional Analysis of Surgical and Oncological Outcomes.

    PubMed

    Musi, Gennaro; Mistretta, Francesco A; Marenghi, Carlo; Russo, Andrea; Catellani, Michele; Nazzani, Sebastiano; Conti, Andrea; Luzzago, Stefano; Ferro, Matteo; Matei, Deliu V; Carmignani, Luca; de Cobelli, Ottavio

    2018-03-01

    To evaluate the efficacy and safety of ureteroscopic thulium laser (TL) treatment of upper urinary tract carcinoma (UTUC). Forty-two consecutive patients underwent conservative TL treatment for UTUC at two referral institutions. All patients underwent preliminary biopsy and then laser vaporization. A 272 μm and 365 μm laser fibers were used with a flexible and semirigid scope, respectively. Ablation was carried out with a 10 to 20 W power. Mean age at surgery was 68 years (SD 10.7). Mean tumor size was 14.3 mm (range 2-30 mm). Preliminary biopsy revealed the presence of low-grade disease in 29 (69.1%) patients, high-grade disease in 4 (9.5%) and 1 carcinoma in situ 1 (2.4%), whereas it was not conclusive in 8 (19%) cases. Final stage was pTa and pTis in 41 (97.6%) and 1 (2.4%) patients, respectively. Thirty eight percent (16) experienced Clavien-Dindo grade I complication, 47.6% (20) grade II, and 2.4% (1) grade III. Five (12%) patients underwent a second-look procedure due to residual disease. Eight (19%) patients experienced clinical recurrence. The median estimated recurrence-free survival was 44 months (SE 3.68). Four patients (9.5%) underwent a nephroureterectomy. Final pathological stage was pTis, pT3 high grade, pTa low grade, and pT0. Median follow-up was 26.3 months (range 2-54 months), and no progression or upstaging of disease occurred. TL management of UTUC is a safe and efficacious conservative treatment. Our experience shows optimal vaporization and hemostatic control in the absence of major complications.

  13. Ureteroscopic treatment of larger renal calculi (>2 cm).

    PubMed

    Bagley, Demetrius H; Healy, Kelly A; Kleinmann, Nir

    2012-09-01

    To evaluate the current status of ureteroscopic lithotripsy (UL) for treating renal calculi of >2 cm, as advances in flexible ureteroscope design, accessory instrumentation and lithotrites have revolutionised the treatment of urinary calculi. While previously reserved for ureteric and small renal calculi, UL has gained an increasing role in the selective management of larger renal stone burdens. We searched the available databases, including PubMed, Google Scholar, and Scopus, for relevant reports in English, and the article bibliographies to identify additional relevant articles. Keywords included ureteroscopy, lithotripsy, renal calculi, and calculi >2 cm. Retrieved articles were reviewed to consider the number of patients, mean stone size, success rates, indications and complications. In all, nine studies (417 patients) were eligible for inclusion. After one, two or three procedures the mean (range) success rates were 68.2 (23-84)%, 87.1 (79-91)% and 94.4 (90.1-96.7)%, respectively. Overall, the success rate was >90% with a mean of 1.2-2.3 procedures per patient. The overall complication rate was 10.3%, including six (1.4%) intraoperative and 37 (8.9%) postoperative complications, most of which were minor. The most common indications for UL were a failed previous treatment (46%), comorbidities (18.2%), and technical and anatomical factors (12.3%). UL is safe and effective for treating large renal calculi. While several procedures might be required for total stone clearance, UL should be considered a standard approach in the urologist's options treating renal calculi of >2 cm.

  14. Preparation of Ho3+/Tm3+ Co-doped Lanthanum Tungsten Germanium Tellurite Glass Fiber and Its Laser Performance for 2.0 μm.

    PubMed

    Zhou, Dechun; Bai, Xuemei; Zhou, Hang

    2017-03-17

    Ho 3+ /Tm 3+ co-doped 50TeO 2 -25GeO 2 -3WO 3 -5La 2 O 3 -3Nb 2 O 5 -5Li 2 O-9BaF 2 glass fiber is prepared with the rod-tube drawing method of 15 μm core diameter and 125 μm inner cladding diameter applied in the 2.0 μm-infrared laser. The 2.0 μm luminescence properties of the core glass are researched and the fluorescence intensity variation for different Tm 3+ doping concentration is systematically analyzed. The results show that the 2.0 μm luminescence of Ho 3+ is greatly influenced by the doping concentration ratio of Ho 3+ to Tm 3+ and that the maximum fluorescence intensity of the core glass can be obtained and its emission cross section can reach 0.933 × 10 -21  cm 2 when the sensitized proportion of holmium to thulium is 0.3 to 0.7 (mol%). Simultaneously, the maximum phonon energy of the core glass sample is 753 cm -1 , which is significantly lower than that of silicate, gallate and germanate glass and the smaller matrix phonon energy can be conductive to the increase 2.0 μm-band emission intensity. The continuous laser with the maximum laser output power of 0.993 W and 2051 nm -wavelength of 31.9%-slope efficiency is output within the 0.5 m glass fiber and the experiment adopts 1560 nm erbium-doped fiber laser(EDFL) as the pump source and the self-built all-fiber laser. Therefore, the glass fiber has excellent laser characteristics and it is suitable for the 2.0 μm-band laser.

  15. Preparation of Ho3+/Tm3+ Co-doped Lanthanum Tungsten Germanium Tellurite Glass Fiber and Its Laser Performance for 2.0 μm

    NASA Astrophysics Data System (ADS)

    Zhou, Dechun; Bai, Xuemei; Zhou, Hang

    2017-03-01

    Ho3+/Tm3+ co-doped 50TeO2-25GeO2-3WO3-5La2O3-3Nb2O5-5Li2O-9BaF2 glass fiber is prepared with the rod-tube drawing method of 15 μm core diameter and 125 μm inner cladding diameter applied in the 2.0 μm-infrared laser. The 2.0 μm luminescence properties of the core glass are researched and the fluorescence intensity variation for different Tm3+ doping concentration is systematically analyzed. The results show that the 2.0 μm luminescence of Ho3+ is greatly influenced by the doping concentration ratio of Ho3+ to Tm3+ and that the maximum fluorescence intensity of the core glass can be obtained and its emission cross section can reach 0.933 × 10-21 cm2 when the sensitized proportion of holmium to thulium is 0.3 to 0.7 (mol%). Simultaneously, the maximum phonon energy of the core glass sample is 753 cm-1, which is significantly lower than that of silicate, gallate and germanate glass and the smaller matrix phonon energy can be conductive to the increase 2.0 μm-band emission intensity. The continuous laser with the maximum laser output power of 0.993 W and 2051 nm -wavelength of 31.9%-slope efficiency is output within the 0.5 m glass fiber and the experiment adopts 1560 nm erbium-doped fiber laser(EDFL) as the pump source and the self-built all-fiber laser. Therefore, the glass fiber has excellent laser characteristics and it is suitable for the 2.0 μm-band laser.

  16. Preparation of Ho3+/Tm3+ Co-doped Lanthanum Tungsten Germanium Tellurite Glass Fiber and Its Laser Performance for 2.0 μm

    PubMed Central

    Zhou, Dechun; Bai, Xuemei; Zhou, Hang

    2017-01-01

    Ho3+/Tm3+ co-doped 50TeO2-25GeO2-3WO3-5La2O3-3Nb2O5-5Li2O-9BaF2 glass fiber is prepared with the rod-tube drawing method of 15 μm core diameter and 125 μm inner cladding diameter applied in the 2.0 μm-infrared laser. The 2.0 μm luminescence properties of the core glass are researched and the fluorescence intensity variation for different Tm3+ doping concentration is systematically analyzed. The results show that the 2.0 μm luminescence of Ho3+ is greatly influenced by the doping concentration ratio of Ho3+ to Tm3+ and that the maximum fluorescence intensity of the core glass can be obtained and its emission cross section can reach 0.933 × 10−21 cm2 when the sensitized proportion of holmium to thulium is 0.3 to 0.7 (mol%). Simultaneously, the maximum phonon energy of the core glass sample is 753 cm−1, which is significantly lower than that of silicate, gallate and germanate glass and the smaller matrix phonon energy can be conductive to the increase 2.0 μm-band emission intensity. The continuous laser with the maximum laser output power of 0.993 W and 2051 nm -wavelength of 31.9%-slope efficiency is output within the 0.5 m glass fiber and the experiment adopts 1560 nm erbium-doped fiber laser(EDFL) as the pump source and the self-built all-fiber laser. Therefore, the glass fiber has excellent laser characteristics and it is suitable for the 2.0 μm-band laser. PMID:28303946

  17. Evaluation of erbium:YAG and holmium:YAG laser radiation and dental hard tissue

    NASA Astrophysics Data System (ADS)

    Attrill, David Cameron

    Lasers have become increasingly established in medicine as effective alternatives or adjuncts to conventional techniques. In dentistry, several clinical laser systems have been developed and marketed, but their applications have been limited to soft tissue surgery. To date, no laser has been capable of effectively cutting or modifying the highly mineralised dental tissues of enamel and dentine. The aim of this study was to evaluate two new laser systems for use in dentistry through a series of in vitro experiments. Both generic erbium and holmium lasers have theoretically superior operating characteristics over currently established lasers for applications with dental hard tissues. The two lasers investigated in this study were pulsed Er:YAG (lambda=2.94) a.m. and Cr-Tm-Ho:YAG (lambda=2.1mu.m). Both operated with a macropulse duration of approximately 200lambdas, at pulse repetition rates of 2-8Hz and mean pulse energies up to 230mJ. Radiation was focused using CaF[2] lenses (f=50-120mm). The lasers could be operated with or without the addition of a surface water film at the interaction site. Tissue removal efficiency was expressed as a latent heat of ablation (LHA, kJ/cm[3]) using a modification of the technique described by Charlton et al. (1990). The mean LHA's for the Er:YAG laser were 6.24kJ/cm[3] and 22.99kJ/cm[3] with dentine and enamel respectively without water, and 10.07kJ/cm[3] and 18.73kJ/cm[3] for dentine and enamel with water. The Cr-Tm-Ho:YAG laser was unable to effectively remove enamel at the fluences and pulse energies available; the mean LHA's for the Cr-Tm- Ho:YAG laser with dentine were 82.79kJ/cm3 and 57.57kJ/cm3 with and without water respectively. The Cr-Tm-Ho;YAG was approximately 8-9 times less efficient for tissue removal than the Er:YAG system. Er:YAG tissue removal with water was characterised by clean "surgical" cuts, comparable in histological appearance to those obtained using conventional instrumentation. Some thermal disruption and evidence of molten enamel in particular were apparent when the Er:YAG laser was used without water. The Cr-Tm-Ho;YAG laser produced extensive charring and carbonisation of tissues. It was concluded that this laser was unsuitable for clinical applications directed at the removal or modification of enamel and dentine, particularly as the Er:YAG laser offers superior qualities. Further research with the Cr-Tm-Ho:YAG laser was discontinued. A comparison of the mean shear bond strengths of a composite (ZlOO, 3M Dental Products) bonded to enamel was made using either a conventional acid etch technique or one of a range of experimental Er:YAG laser etching configurations. The mean values for acid etching (16.6 MPa) were in all cases significantly greater (p<0.01, Bonferroni) than those obtained with laser etching. The optimal laser etching parameters were a fluence of 24J/cm[2] (1/e[2] calculation) with water resulting in a mean bond strength of 11.5 MPa. This figure represents approximately 70% of the mean obtained with acid etching, and was significantly greater (p<0.01, Bonferroni) than the mean recorded for non etched negative control surfaces (4.4 MPa). Histological evaluation of the etched surfaces demonstrated clear differences in the etching patterns observed between laser and acid etching. Some surface cracking was noted in most laser etched surfaces, but the extent of this was minimised when the laser was applied in conjunction with a surface water film. Pulpal temperature increments following Er:YAG laser irradiation were significantly lower in teeth prepared with water than without (paired t-test, p<0.01). The largest increment in samples prepared with water was 3.9°C, compared to 24.7°C without water. The principal determinant of the temperature increment in either group was the total delivered energy, up to 140J. Linear regression modelling predicts that continuous irradiation up to 160J with water would not result in iatrogenic pulpal damage. In conclusion, the Er:YAG laser was shown to be an effective tool for cutting and modifying dental hard tissues. It almost certainly offers the best combination of safety, efficiency and speed of any laser system designed for preparing cavities. The laser must be used in conjunction with a water coolant on the tissues to minimise the possibility of iatrogenic damage, improve the quality of the laser cuts and in some circumstances increase cutting efficiency. The Er:YAG laser has shown much promise in these in vitro experiments and its progression to clinical use is supported. The Cr-Tm-Ho:YAG laser is significantly less efficient and in vitro results are unfavourable in comparison with the Er:YAG laser. Its clinical use is not supported.

  18. Application of the holmium:YAG laser for refractive surgery: an update of clinical progress

    NASA Astrophysics Data System (ADS)

    Thompson, Vance M.; Durrie, Daniel S.; Hunkeler, John D.; Hurt, Art C., III; Mann, P. M.; Seiler, Theo; King, Michael C.; Sacharoff, Alex C.; Muller, David F.

    1993-06-01

    We describe the results of a 30 patient Phase I clinical trial using the Laser Thermokeratoplasty (LTK) treatment for correction of hyperopic astigmatism. We report the results for 29 patients who have reached 2 months post-operative. The average pre-op cylinder was reduced from -3.06 Diopters (D) to -1.21 D. Average spherical equivalent (SE) refractive error was reduced from +2.28 to +1.34 D. Six patients have reached 4 months post-op; the average cylinder of these patients has been reduced from -1.92 to -0.79 D while the average SE has been reduced from +1.29 to +0.31 D. Although patients had varying degrees of astigmatism pre-op, all treatments were performed with identical parameters (intended to correct a small amount of astigmatism) to enable us to determine the effect of the procedure without the influence of other factors such as varying zone diameter or laser fluence. The predictability and stability of the LTK procedure are supported by a recent study of 20 patients treated in Germany by Seiler for low to moderate degrees (2 - 4 D) of hyperopia. After 6 months post-op, 16 of 20 patients are within +/- 1 D of the attempted correction. Longer-term follow-up will be necessary to determine the ultimate refractive stability of the LTK procedure.

  19. Mid-Infrared Laser Orbital Septal Tightening

    PubMed Central

    Chu, Eugene A.; Li, Michael; Lazarow, Frances B.; Wong, Brian J. F.

    2014-01-01

    IMPORTANCE Blepharoplasty is one of the most commonly performed facial aesthetic surgeries. While myriad techniques exist to improve the appearance of the lower eyelids, there is no clear consensus on the optimal management of the orbital septum. OBJECTIVES To evaluate the safety and feasibility of the use of the holmium:yttrium aluminum garnet (Ho:YAG) laser for orbital septal tightening, and to determine whether modest use of this laser would provide some degree of clinical efficacy. DESIGN, SETTING, AND PARTICIPANTS Direct laser irradiation of ex vivo bovine tissue was used to determine appropriate laser dosimetry using infrared thermal imaging and optical coherence tomography before conducting a pilot clinical study in 5 patients. Laser irradiation of the lower eyelid orbital septum was performed through a transconjunctival approach. Standardized preoperative and postoperative photographs were taken for each patient and evaluated by 6 unbiased aesthetic surgeons. EXPOSURE Use of the Ho:YAG laser for orbital septal tightening. MAIN OUTCOME AND MEASURE To determine appropriate laser dosimetry, infrared thermal imaging and optical coherence tomography were used to monitor temperature and tissue shape changes of ex vivo bovine tissue that was subjected to direct laser irradiation. For the clinical study, preoperative and postoperative photographs were evaluated by 6 surgeons on a 10-point Likert scale. RESULTS Optical coherence tomography demonstrated that laser irradiation of bovine tissue to a temperature range of 60°C to 80°C resulted in an increase in thickness of up to 2-fold. There were no complications or adverse cosmetic outcomes in the patient study. Patient satisfaction with the results of surgery averaged 7 on a 10-point Likert scale. For 3 patients, 3 (50%) of the evaluators believed there was a mild improvement in appearance of the lower eyelids after surgery. The remaining patients were thought to have no significant changes. CONCLUSIONS AND RELEVANCE Transconjunctival Ho:YAG laser blepharoplasty is a safe procedure that may ameliorate mild pseudoherniation of lower eyelid orbital fat and is a first step toward the development of percutaneous techniques. LEVEL OF EVIDENCE 4. PMID:25275274

  20. Flexible ureterorenoscopy in position or fusion anomaly: Is it feasible?

    PubMed

    Astolfi, Rafael Haddad; Freschi, Gustavo; Berti, Fernando Figueiredo; Gattas, Nelson; Molina, Wilson Rica; Meller, Alex

    2017-08-01

    To analyze the results of flexible ureterorenoscopy (F-URS) with holmium laser in the treatment of kidney stones with ectopic and fusion anomalies (horseshoe kidney and rotation anomalies). We reviewed data from 13 patients with fusion and ectopic renal anomalies that underwent F-URS from April 2011 to April 2017. We analyzed demographic and clinical data (age, gender, BMI, anatomical abnormality, location and dimension of the renal calculi) and perioperative data (method of treatment, stone-free rate, number of days with DJ catheter and perioperative complications). The mean stone size was 12.23 +/- 5.43 mm (range 6-22mm), located in the inferior (58.33%) and middle (16.76%) calyceal units, renal pelvis (16.67%) and multiple locations (8.33%). All 13 patients were treated with Ho-Yag laser, using dusting technique (25%), fragmentation and extraction of the calculi (58.33%) and mixed technique (16.67%). We did not have any severe perioperative complication. After 90 days, nine patients (75%) were considered stone free. Our data suggest that F-URS is a safe and feasible choice for the treatment of kidney stones in patients with renal ectopic and fusion anomalies.

  1. Innovations in surgical stone disease.

    PubMed

    Antonelli, Jodi A

    2016-05-01

    Urinary stone disease is a condition characterized by a rich history of surgical innovation. Herein, we review the new ideas, devices and methods that are the cornerstones of contemporary surgical innovation in stone disease, specifically flexible ureteroscopy and percutaneous nephrolithotomy. The new ideas being applied to flexible ureteroscopy include extending the boundaries of surgical indications and eliminating the need for intraoperative fluoroscopy. Device advancements include disposable ureteroscopes and flexi semirigid ureteroscopes. Robotic flexible ureteroscopy, the use of magnets and mobile technology applications represent progress in methods of performing flexible ureteroscopy. Three-dimensional computed tomography and printing technology are enhancing percutaneous renal access. Novel image-guided access techniques are improving the accuracy of percutaneous surgery particularly for complex cases. New ideas, devices and methods are continuing to reshape the landscape of surgical stone treatment and in so doing not only have the potential to improve surgical outcomes but also to cultivate further scientific and technological advancements in this area.

  2. Impact of the Curve Diameter and Laser Settings on Laser Fiber Fracture.

    PubMed

    Haddad, Mattieu; Emiliani, Esteban; Rouchausse, Yann; Coste, Frederic; Doizi, Steeve; Berthe, Laurent; Butticé, Salvatore; Somani, Bhaskar; Traxer, Olivier

    2017-09-01

    To analyze the risk factors for laser fiber fractures when deflected to form a curve, including laser settings, size of the laser fiber, and the fiber bending diameter. Single-use 272 and 365 μm fibers (Rocamed ® , Monaco) were employed along with a holmium laser (Rocamed). Five different fiber curve diameters were tested: 9, 12, 15, 18, and 20 mm. Fragmentation and dusting settings were used at a theoretical power of 7.5 W. The laser was activated for 5 minutes and the principal judgment criterion was fiber fracture. Every test for each parameter, bending diameter, and fiber size combinations was repeated 10 times. With dusting settings, fibers broke more frequently at a curved diameter of 9 mm for both 272 and 365 μm fibers (p = 0.037 and 0.006, respectively). Using fragmentation settings, fibers broke more frequently at 12 mm for 272 μm and 15 mm for 365 μm (p = 0.007 and 0.033, respectively). Short pulse and high energy were significant risk factors for fiber fracture using the 365 μm fibers (p = 0.02), but not for the 272 μm fibers (p = 0.35). Frequency was not a risk factor for fiber rupture. Fiber diameters also seemed to be involved in the failure with a higher number of broken fibers for the 365 μm fibers, but this was not statistically significant when compared with the 272 μm fibers (p > 0.05). Small-core fibers are more resistant than large-core fibers as lower bending diameters (<9 mm) are required to break smaller fibers. In acute angles, the use of small-core fibers, at a low energy and long-pulse (dusting) setting, will reduce the risk of fiber rupture.

  3. Concomitant treatment of ureteropelvic junction obstruction and renal calculi with robotic laparoscopic surgery and rigid nephroscopy.

    PubMed

    Zheng, Ji; Yan, Junan; Zhou, Zhansong; Chen, Zhiwen; Li, Xin; Pan, Jinhong; Li, Weibing

    2014-01-01

    The treatment of ureteropelvic junction obstruction (UPJO) and concomitant calculus poses a technically challenging situation. We present our experience with using rigid nephroscopy for renal calculi removal during robot-assisted pyeloplasy (RAP) for UPJO. From December 2010 to November 2012, 25 patients with UPJO had RAP at our institution; 9 of those had concurrent renal calculi, which were simultaneously treated with rigid nephroscopy. For stone extraction, a rigid ureteroscope was passed through an assistant trocar under laparoscopic vision directly into a previously created pyelotomy. The stones were extracted using a rigid grasper or stone basket through the rigid ureteroscope. For the removal of the stones within the upper and lower calyces, the rigid ureteroscope was introduced into the incised renal pelvis through robotic trocars if the "assistant trocar" route failed. Complete stone clearance was achieved in 8 of 9 patients. Residual calculi in 1 patient were removed with a single session of extracorporeal shock wave lithotripsy. At the mean follow-up of 10.2 months, no patients had obstruction or recurrent stones. The mean operative time was 187.1 minutes, which was 40.9 minutes longer than the mean operative time in patients without renal calculi. There was no significant difference in blood loss, hospital stay, complications, and success rates between patients with and without renal calculi. Our data suggest that the use of a concomitant rigid nephroscope and RAP is a safe and feasible option for the treatment of UPJO complicated with renal calculi. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Minimally invasive percutaneous nephrolithotomy in preschool age children with kidney calculi (including stones induced by melamine-contaminated milk powder).

    PubMed

    Yan, Xiang; Al-Hayek, Samih; Gan, Weidong; Zhu, Wei; Li, Xiaogong; Guo, Hongqian

    2012-10-01

    This study was undertaken to assess the safety and efficacy of minimally invasive percutaneous nephrolithotomy (mini-PCNL) using ureteroscope and pneumatic intracorporeal lithotripsy in preschool age children with kidney calculi. We studied 27 renal units in 20 patients of preschool age (≤ 6 years) who underwent mini-PCNL at our institute. The mean age was 42.6 months (range 14-68 months). The average stone burden was 1.85 cm (range 0.9-2.8 cm). Eight patients aged 14 to 58 months had been exposed to melamine-tainted powdered formula. The mini-PCNL was performed with an X-ray-guided peripheral puncture. Minimal tract dilatation was undertaken to fit a 14-16 Fr peel-away sheath. Ureteroscope and pneumatic intracorporeal lithotripsy were used to fragment the stones. Complete clearance was achieved in 23 renal units (85.2 %) with mini-PCNL monotherapy. This has increased to 92.6 % after adjunctive ESWL. The average fall in hemoglobin was 1.28 g/dL. None of the patients required blood transfusion. The median length of hospital stay was 8.2 days. Patients were followed up every 6 months for 2 years. There has been only one recurrence of stone and no long-term complications. Mini-PCNL is a effective treatment for pediatric kidney stones refractory to extracorporeal shock wave lithotripsy, including stones induced by melamine-contaminated milk powder. The "mini-PCNL" technique, which uses ureteroscope and pneumatic intracorporeal lithotripsy, is a safe and feasible modality for treating renal calculi in preschool age children.

  5. Ureteroscopic treatment of larger renal calculi (>2 cm)

    PubMed Central

    Bagley, Demetrius H.; Healy, Kelly A.; Kleinmann, Nir

    2012-01-01

    Objectives To evaluate the current status of ureteroscopic lithotripsy (UL) for treating renal calculi of >2 cm, as advances in flexible ureteroscope design, accessory instrumentation and lithotrites have revolutionised the treatment of urinary calculi. While previously reserved for ureteric and small renal calculi, UL has gained an increasing role in the selective management of larger renal stone burdens. Methods We searched the available databases, including PubMed, Google Scholar, and Scopus, for relevant reports in English, and the article bibliographies to identify additional relevant articles. Keywords included ureteroscopy, lithotripsy, renal calculi, and calculi >2 cm. Retrieved articles were reviewed to consider the number of patients, mean stone size, success rates, indications and complications. Results In all, nine studies (417 patients) were eligible for inclusion. After one, two or three procedures the mean (range) success rates were 68.2 (23–84)%, 87.1 (79–91)% and 94.4 (90.1–96.7)%, respectively. Overall, the success rate was >90% with a mean of 1.2–2.3 procedures per patient. The overall complication rate was 10.3%, including six (1.4%) intraoperative and 37 (8.9%) postoperative complications, most of which were minor. The most common indications for UL were a failed previous treatment (46%), comorbidities (18.2%), and technical and anatomical factors (12.3%). Conclusions UL is safe and effective for treating large renal calculi. While several procedures might be required for total stone clearance, UL should be considered a standard approach in the urologist’s options treating renal calculi of >2 cm. PMID:26558040

  6. A laser-induced pulsed water jet for layer-selective submucosal dissection of the esophagus

    PubMed Central

    Sato, C; Yamada, M; Nakagawa, A; Yamamoto, H; Fujishima, F; Tominaga, T; Satomi, S; Ohuchi, N

    2016-01-01

    Background and aims: Conventional water jet devices have been used for injecting fluid to lift up lesions during endoscopic submucosal dissection or endoscopic mucosal resection procedures. However, these devices cannot dissect the submucosal layer effectively. Here we aim to elucidate the dissection capability of a laser-induced pulsed water jet and to clarify the mechanism of dissection with layer selectivity. Materials (Subjects) and methods: Pulsed water jets were ejected from a stainless nozzle by accelerating saline using the energy of a pulsed holmium: yttrium-aluminum-garnet laser. The impact force (strength) of the jet was evaluated using a force meter. Injection of the pulsed jet into the submucosal layer was documented by high-speed imaging. The physical properties of the swine esophagus were evaluated by measuring the breaking strength. Submucosal dissection of the swine esophagus was performed and the resection bed was evaluated histologically. Results: Submucosal dissection of the esophagus was accomplished at an impact force of 1.11–1.47 N/pulse (laser energy: 1.1–1.5 J/pulse; standoff distance: 60 mm). Histological specimens showed clear dissection at the submucosal layer without thermal injury. The mean static breaking strength of the submucosa (0.11 ± 0.04 MPa) was significantly lower than that of the mucosa (1.32 ± 0.18 MPa), and propria muscle (1.45 ± 0.16 MPa). Conclusions: The pulsed water jet device showed potential for achieving selective submucosal dissection. It could achieve mucosal, submucosal, and muscle layer selectivity owing to the varied breaking strengths. PMID:27853343

  7. Ureteroscopic Lithotripsy

    PubMed Central

    Bagley, Demetrius H.

    1997-01-01

    There is a wide array of endoscopic lithotriptors presently available. Each of these has its own advantages and disadvantages. No single lithotriptor is suitable for all applications and none can meet the goal of fragmenting all calculi while remaining harmless to tissue. PMID:18493444

  8. Inside HOLMES experiment: 163Ho metallic target production for the micro-calorimeter absorber

    NASA Astrophysics Data System (ADS)

    Pizzigoni, G.; Alpert, B.; Balata, M.; Bennett, D.; Biasotti, M.; Boragno, C.; Brofferio, C.; De Gerone, M.; Dressler, R.; Faverazani, M.; Ferri, E.; Folwer, J.; Gatti, F.; Giachero, A.; Heinitz, S.; Hilton, G.; Köster, U.; Lusignoli, M.; Maino, M.; Mates, J.; Nisi, S.; Nizzolo, R.; Nucciotti, A.; Pessina, G.; Puiu, A.; Ragazzi, S.; Reintsema, C.; Ribeiro Gomes, M.; Shmidt, D.; Schumann, D.; Sisti, M.; Swetz, D.; Terranova, F.; Ullom, J.; Day, P. K.

    2016-07-01

    The main goal in the HOLMES experiment is the neutrino mass measurement using an array of 1000 micro-calorimeters with standard metallic absorber. A good isotope for such measurement is the 163Ho, those isotopes embedded in the metallic absorber will be 1011-1013. Since 163Ho is not available in nature, a dedicated process must be set up to produce the amount needed for this neutrino mass experiment. The process with the highest born-up cross-section is the neutron irradiation of Er2O3 enriched in 162Er: 162Er(n,γ)163Er →163Ho+νe, where the decay is an EC with half-life of about 75 min and the (n,γ) is about 20 barns for thermal neutron. After the neutron irradiation in the oxide powder there are several radioactive isotopes which are potentially disturbing because of the background that they cause below 5 keV. The chemical separation of holmium from the irradiation enriched Er2O3 powder is therefore mandatory and will be performed by means of ion exchange chromatography. On the end of those processes the oxide powder enriched in 162Er will have the 163Ho isotope number required. The holmium chemical state influences the end point of the EC spectrum, in order to avoid such effect it is necessary to embed in the absorber only the metallic isotope. Reduction and distillation technique allowed us to obtain a pure metallic holmium, starting from natural oxide holmium. This technique will be applied on the irradiated oxide powder to obtain the metallic 163Ho, ready to be embedded in the micro-calorimeter absorber.

  9. New, efficient, room temperature mid-infrared laser at 3.9 mu m in holmium:barium yttrium fluoride and visible praseodymium:lithium yttrium fluoride laser for holography

    NASA Astrophysics Data System (ADS)

    Tabirian, Anna Murazian

    This dissertation describes a series of experiments and theoretical studies, which led to the development of two new solid state laser systems: efficient, room temperature mid-infrared solid state laser at 3.9 μm in Ho 3+ doped BaY2F8 and visible Pr:LiYF4 laser at 640 mn for holography. The 3.9 μm laser wavelength matches the peak of mid-IR atmospheric transmission window, which makes it very important for multiple applications such as remote sensing, imaging, IR countermeasures, eye-safe lidars and environmental agent detection. We present the results of spectroscopic evaluations and numerical modeling of energy transfer processes between rare earth ions of Ho3+ doped in two host laser materials: BaY2F8 and LiYF 4. The 3.9 μm laser is based on transition with upper laser lifetime considerably shorter than lower level lifetime, which in general leads to self-terminating laser action in the cw mode or at high repetition rates. Therefore, three different pumping and lasing schemes, that could allow overcoming these limitations have been suggested and studied. First, cascade laser action at 1.4 μm and 3.9 μm was achieved with low thresholds and near-theoretical quantum efficiency in Ho3+ doped BaY2F8 pumped at 532 nm by a Q- switched frequency doubled Nd:YAG laser. Next, the feasibility of achieving 3.9 μm laser with cw resonant cascade pumping at 750 mn by a Ti:Sapphire laser was studied. New energy transfer process, such as upconversion from terminal level of the 3.9 μm laser was observed in high concentration Ho3+ doped BaY2F 8. Finally, we proposed to use high-energy flashlamp pumped tunable Cr:LiSAF laser operating in long pulse regime for the direct pumping of the upper level of the 3.9 μm laser. Pulsed laser oscillation at 3.9 μm is demonstrated in Ho3+ doped BaY2F8 with low threshold of 3 mJ and a slope efficiency of 14.5% with maximal energy of 30 mJ. The second part of the thesis describes the design and the development of the visible Pr:LiYF4 laser for holography at 640 nm resonantly pumped by the frequency-doubled flashlamp pumped tunable Cr:LiSAF laser at 444 nm.

  10. Holmium laser enucleation versus simple prostatectomy for treating large prostates: Results of a systematic review and meta-analysis.

    PubMed

    Jones, Patrick; Alzweri, Laith; Rai, Bhavan Prasad; Somani, Bhaskar K; Bates, Chris; Aboumarzouk, Omar M

    2016-03-01

    To compare and evaluate the safety and efficacy of holmium laser enucleation of the prostate (HoLEP) and simple prostatectomy for large prostate burdens, as discussion and debate continue about the optimal surgical intervention for this common pathology. A systematic search was conducted for studies comparing HoLEP with simple prostatectomy [open (OP), robot-assisted, laparoscopic] using a sensitive strategy and in accordance with Cochrane collaboration guidelines. Primary parameters of interest were objective measurements including maximum urinary flow rate (Q max) and post-void residual urine volume (PVR), and subjective outcomes including International Prostate Symptom Score (IPSS) and quality of life (QoL). Secondary outcomes of interest included volume of tissue retrieved, catheterisation time, hospital stay, blood loss and serum sodium decrease. Data on baseline characteristics and complications were also collected. Where possible, comparable data were combined and meta-analysis was conducted. In all, 310 articles were identified and after screening abstracts (114) and full manuscripts (14), three randomised studies (263 patients) were included, which met our pre-defined inclusion criteria. All these compared HoLEP with OP. The mean transrectal ultrasonography (TRUS) volume was 113.9 mL in the HoLEP group and 119.4 mL in the OP group. There was no statistically significant difference in Q max, PVR, IPSS and QoL at 12 and 24 months between the two interventions. OP was associated with a significantly shorter operative time (P = 0.01) and greater tissue retrieved (P < 0.001). However, with HoLEP there was significantly less blood loss (P < 0.001), patients had a shorter hospital stay (P = 0.03), and were catheterised for significantly fewer hours (P = 0.01). There were no significant differences in the total number of complications recorded amongst HoLEP and OP (P = 0.80). The results of the meta-analysis have shown that HoLEP and OP possess similar overall efficacy profiles for both objective and subjective disease status outcome measures. This review shows these improvements persist to at least the 24 month follow-up point. Further randomised studies are warranted to fully determine the optimal surgical intervention for large prostate burdens.

  11. The Difficult Ureter: Clinical and Radiographic Characteristics Associated With Upper Urinary Tract Access at the Time of Ureteroscopic Stone Treatment.

    PubMed

    Viers, Boyd R; Viers, Lyndsay D; Hull, Nathan C; Hanson, Theodore J; Mehta, Ramila A; Bergstralh, Eric J; Vrtiska, Terri J; Krambeck, Amy E

    2015-11-01

    To evaluate the association between clinicoradiographic features and need for prestenting (PS) because of inability of the ureter to accommodate the ureteroscope, or ureteral access sheath, at the time of stone treatment. From 2009 to 2013, 120 consecutive nonstented patients underwent ureteroscopic stone treatment with preoperative computerized tomography urogram. Acute stone events with obstruction or infection were excluded. Preoperative radiographic imaging underwent radiologist review. Clinicoradiographic features were characterized, and multivariable logistic regression models were used to identify covariates independently associated with need for PS. Of the 154 renal units treated, 25 (16%) required PS for failed primary access. PS ureters were less likely to have a history of prior ipsilateral ureteral stent (4% vs 31%) or surgery (8% vs 36%; P <.05). Radiographically, PS ureters had a narrower ureteropelvic junction (4 mm vs 5 mm) and were more likely to have <50% ureteral opacification on computerized tomography urogram (32% vs 9%; P <.05). On multivariable analysis, prior ipsilateral ureteral stent (odds ratio [OR] = 0.11) and stone surgery (OR = 0.15) reduced the need for PS; meanwhile, <50% ureteral opacification (OR = 4.41) was independently associated with an increased risk of access failure. We report a 16% incidence of access failure requiring PS at time of ureteroscopy. Clinically, there was an 89% and 85% risk reduction in the need for PS with prior history of ipsilateral ureteral stent or surgery. Radiographically, there was a 4.4-fold increased risk of PS with <50% ureteral opacification. Accordingly, our findings may assist in counseling and operative management of the difficult ureter. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. [Influence of lithotripsy modalities on complication rate].

    PubMed

    Radulović, Slobodan; Milenković-Petronić, Dragica; Vuksanović, Aleksandar; Vavić, Bozo

    2009-01-01

    Localization of ureteric stones and difference in disintegration success are the most important factors in determining the first treatment approach for ureteric stones. The aim of our study was to evaluate the difference in complication rate between different ureteric stone litho-tripsy modalities. Two hundred sixty patients with ureteric stones were analyzed in a prospective bicentric study that lasted 1 year.The patients were divided into two groups: 1-120 patients who underwent ESWL (extracorporeal shockwave lithotripsy) treatment and II-140 patients who were treated endoscopically with ballistic lithotripsy. RESULTS Ureteroscopic lithotripsy of all pelvic and iliac stones was significantly more successful comparing to ESWL, while lumbar ureteric stone treatment with ureteroscopic lithotripsy was not significantly more successful than ESWL, except for lumbar stones larger than 100mm2 that were significantly better treated endoscopically. In the I group complications after lithotripsy were recorded in 64 (59.3%) and in the II group in 58 (42.0%) patients, meaning that complications were statistically significantly more frequent in the I than in the II group. In the II group complications were significantly more often recorded after treatment of proximal comparing to ureteric stones of other localizations, while in the I group complica-tions were significantly more often detected after treatment of impacted stones than in the II group. Being significantly successful comparing to ESWL, ureteric stone treatment with ureteroscopic lithotripsy should be considered as the first therapeutic option for all, especially impacted stones located in the iliac and pelvic ureteric portion. In spite of absent statistical difference in the success rate, ESWL should be chosen as the first treatment option in all cases of lumbar ureteric stones due to lower complication rate except for stones larger than 100mm2that should be primarily treated endoscopically.

  13. Pre-Emptive Tramadol Could Reduce Pain after Ureteroscopic Lithotripsy

    PubMed Central

    Denčić, Nataša; Jovičić, Jelena; Mirković, Jelena; Durutović, Otaš; Milenković-Petronić, Dragica; Lađević, Nebojša

    2014-01-01

    Purpose Optimal analgesia in ambulatory urology patients still remains a challenge. The aim of this study was to examine if the pre-emptive use of intravenous tramadol can reduce pain after ureteroscopic lithotripsy in patients diagnosed with unilateral ureteral stones. Materials and Methods This prospective pilot cohort study included 74 patients diagnosed with unilateral ureteral stones who underwent ureteroscopic lithotripsy under general anesthesia in the Urology Clinic at the Clinical Center of Serbia from March to June 2012. All patients were randomly allocated to two groups: one group (38 patients) received intravenous infusion of tramadol 100 mg in 500 mL 0.9%NaCl one hour before the procedure, while the other group (36 patients) received 500 mL 0.9%NaCl at the same time. Visual analogue scale (VAS) scores were recorded once prior to surgery and two times after the surgery (1 h and 6 h, respectively). The patients were prescribed additional postoperative analgesia (diclofenac 75 mg i.m.) when required. Pre-emptive effects of tramadol were assessed measuring pain scores, VAS1 and VAS2, intraoperative fentanyl consumption, and postoperative analgesic requirement. Results The average VAS1 score in the tramadol group was significantly lower than that in the non-tramadol group. The difference in average VAS2 score values between the two groups was not statistically significant; however, there were more patients who experienced severe pain in the non-tramadol group (p<0.01). The number of patients that required postoperative analgesia was not statistically different between the groups. Conclusion Pre-emptive tramadol did reduce early postoperative pain. The patients who received pre-emptive tramadol were less likely to experience severe post-operative pain. PMID:25048508

  14. Pre-emptive tramadol could reduce pain after ureteroscopic lithotripsy.

    PubMed

    Mimić, Ana; Denčić, Nataša; Jovičić, Jelena; Mirković, Jelena; Durutović, Otaš; Milenković-Petronić, Dragica; Lađević, Nebojša

    2014-09-01

    Optimal analgesia in ambulatory urology patients still remains a challenge. The aim of this study was to examine if the pre-emptive use of intravenous tramadol can reduce pain after ureteroscopic lithotripsy in patients diagnosed with unilateral ureteral stones. This prospective pilot cohort study included 74 patients diagnosed with unilateral ureteral stones who underwent ureteroscopic lithotripsy under general anesthesia in the Urology Clinic at the Clinical Center of Serbia from March to June 2012. All patients were randomly allocated to two groups: one group (38 patients) received intravenous infusion of tramadol 100 mg in 500 mL 0.9%NaCl one hour before the procedure, while the other group (36 patients) received 500 mL 0.9%NaCl at the same time. Visual analogue scale (VAS) scores were recorded once prior to surgery and two times after the surgery (1 h and 6 h, respectively). The patients were prescribed additional postoperative analgesia (diclofenac 75 mg i.m.) when required. Pre-emptive effects of tramadol were assessed measuring pain scores, VAS1 and VAS2, intraoperative fentanyl consumption, and postoperative analgesic requirement. The average VAS1 score in the tramadol group was significantly lower than that in the non-tramadol group. The difference in average VAS2 score values between the two groups was not statistically significant; however, there were more patients who experienced severe pain in the non-tramadol group (p<0.01). The number of patients that required postoperative analgesia was not statistically different between the groups. Pre-emptive tramadol did reduce early postoperative pain. The patients who received pre-emptive tramadol were less likely to experience severe post-operative pain.

  15. Results of minimally invasive surgical treatment of allograft lithiasis in live-donor renal transplant recipients: a single-center experience of 3758 renal transplantations.

    PubMed

    Sarier, Mehmet; Duman, Ibrahim; Yuksel, Yucel; Tekin, Sabri; Demir, Meltem; Arslan, Fatih; Ergun, Osman; Kosar, Alim; Yavuz, Asuman Havva

    2018-02-26

    Allograft lithiasis is a rare urologic complication of renal transplantation (RT). Our aim is to present our experience with minimally invasive surgical treatment of allograft lithiasis in our series of live-donor renal transplant recipients. In a retrospective analysis of 3758 consecutive live-donor RTs performed in our center between November 2009 and January 2017, the results of minimally invasive surgery for the treatment of renal graft lithiasis diagnosed at follow-up were evaluated. Twenty-two (0.58%) patients underwent minimally invasive surgery for renal graft lithiasis. The mean age was 41.6 years, and duration between RT and surgical intervention was 27.3 months (range 3-67). The mean stone size was 11.6 mm (range 4-29). Stones were located in the urethra in 1, bladder in 2, ureter in 9, renal pelvis in 7 and calices in 3 patients. Surgical treatment included percutaneous nephrolithotomy in 1, cystoscopic lithotripsy in 3, flexible ureteroscopic lithotripsy in 6 and rigid ureteroscopic lithotripsy in 12 patients. No major complications were observed. One patient (4.5%) who underwent flexible ureteroscopy developed postoperative urinary tract infection. All patients were stone-free except two (9%) patients who required a second-look procedure after flexible ureteroscopic lithotripsy for residual stones. Stone recurrence was not observed in any patient during a mean follow-up duration of 30.2 months (range 8-84). Renal transplant lithiasis is uncommon and minimally invasive surgical treatment is rarely performed for its treatment. Endourological surgery may be performed safely, effectively and with a high success rate in these patients.

  16. Stenting versus non-stenting following uncomplicated ureteroscopic lithotripsy: Comparsion and evaluation of symptoms.

    PubMed

    Savić, Slaviša; Vukotić, Vinka; Lazić, Miodrag; Savić, Nataša

    2016-09-01

    Currently, ureterorenoscopic (URS) stone fragmentation and removal is the treatment of choice for managing ureteral stones, especially mid and distal ones and is advocated as initial management of ureteric stones. The aim of this work was to evaluate the symptoms, necessity, potential benefits and adverse effects of ureteral stent placement after uncomplicated ureteroscopic lithotripsy. This retrospective-prospective study evaluated a total of 125 patients who had underwent ureteroscopic lithotripsy (URSL). The patients were divided into two groups: stented (59 patients) and unstented (controls, 66 patients). The outcomes measured and compared between the two groups included: stone free rate, postoperative patient pain validated by scale, lower urinary tract symptoms (LUTS), the need for unplanned hospital care, stent related complications, and functional recovery in the form return to normal physical activities. A successful outcome, defined as being stonefree after 12 weeks, was achieved in all 125 (100%) patients. The stone-free rate showed no significant differences between the two groups. LUTS was frequent complaint in the stented group, with statistically significant difference in the domain of frequency/urgency (p = 0.0314). There was a statistically significant difference between the groups in the mean operative time and mean hospitalization time, mean pain visual analog scale (VAS) score and in the use of nonnarcotic analgesic. On the day of the surgery and until postoperative day 3 (POD 3) and postoperative day 5 (POD 5), the pain score was much higher among stented patients than among the controls (p = 0.0001) and non-narcotic analgesic use (p = 0.001) was frequently required in the stented group. Routine placement of ureteral stent after URSL is not mandatory and may be associated with stent side effects. Uncomplicated URSL is safe without stent placement after the treatment.

  17. Randomized study of percutaneous ureteroscopic plasma column electrode decortication and laparoscopic decortication in managing simple renal cyst.

    PubMed

    Liu, Weiguang; Zhang, Chengrong; Wang, Bohan; Li, Bao; Gao, Guojun; Sun, Guobao; Sun, Yuansheng; Lin, Guiting

    2018-04-01

    To assess the safety and efficacy of a novel technology referred to as percutaneous ureteroscopic plasma column electrode (PCE) by comparing laparoscopic decortication in the management of simple renal cyst (SRC). Between March 2016 and June 2017, 53 patients with SRCs were randomized to divided into two groups, the PCE group (24 patients), or laparoscope group (29 patients). The operative time, blood loss, days of drainage, catheter, and hospital stay and complications were compared with the two groups. All patients were followed- up to 6 months after treatment. No patients had intraoperative complications such as hemopneumothorax, adjacent organ injury, infection or hemorrhage shock. In the PCE group and laparoscope group: the mean operation time was 34.1±8.2 vs. 58.4±16.7 min (P<0.05). The mean blood loss was 2.0±1.16 vs. 9.7±4.09 mL (P<0.05). The mean postoperative indwelling drainage tube time was 2.5±1.5 vs. 2.9±1.09 d (P>0.05). The mean intra-urethral indwelling catheter time was 2.1±0.88 vs. 2.0±1.15 d (P>0.05). The mean postoperative hospital stay was 3.0±1.7 vs. 3.7±1.53 (P>0.05). One patient in electrode group was suffered from rupture of the collecting system during the operation, and was treated by indwelling D-J stent. During follow up, no cysts recurrence was found. Percutaneous ureteroscopic PCE decortication is a safe, minimally invasive and effective therapy to treat SRCs, with equal efficacy and advantages in shortening the operation time and reducing the amount of intraoperative bleeding compared with laparoscopic decortication.

  18. Intracorporeal lithotripsy. Update on technology.

    PubMed

    Zheng, W; Denstedt, J D

    2000-05-01

    The number and variety of devices currently available for endoscopic lithotripsy reflect the reality that no single device is ideal in all situations. Although the search for the universal lithotriptor continues, the urologist must consider several factors if faced with the decision of which device to purchase. Perhaps foremost among these factors is the clinical situation with which one commonly deals. For example, although the smaller, flexible probes such as EHL or laser demonstrate considerable utility if used ureteroscopically, the larger stone burden associated with today's percutaneous nephrolithotripsy population often is treated more efficiently with one of the mechanical devices employing a larger, rigid probe, such as ultrasound or the Lithoclast. Similarly, the type and size of endoscopic equipment at one's disposal have a significant impact on which device to purchase or use. There are physical constraints affecting which device may or may not be used, rigid versus flexible endoscope, working channel caliber, and offset versus end-on-port. The skill and experience of the surgeon is also a factor of obvious importance, particularly if one is using a modality with a relatively narrow margin of safety such as EHL. Likewise, the training and experience of nursing personnel is a factor, especially regarding the use of lasers, which require certified personnel who are well versed in laser safety. Finally, in today's environment one must carefully evaluate cost in terms of not only initial capital outlay but also ongoing charges for disposable and maintenance items. Thus, the decision of which device to purchase is complex and requires careful evaluation of all of the previously noted variables. Likewise, if one is fortunate enough to have more than one device available, the decision of which lithotriptor to employ requires a similar decision based on sound surgical judgment.

  19. Intrinsic Studies of Materials.

    DTIC Science & Technology

    RELAXATION TIME , CRYSTAL LATTICES), (*RARE EARTH ELEMENTS, *ELECTRON TRANSITIONS), (*CRYSTAL DEFECTS, INTERACTIONS), EXCITATION, DOPING, LANTHANUM COMPOUNDS, PHONONS, ATOMIC ENERGY LEVELS, HOLMIUM, CHLORIDES, PRASEODYMIUM

  20. Application of the holmium:YAG laser for refractive surgery III

    NASA Astrophysics Data System (ADS)

    Thompson, Vance M.; Seiler, Theo; Sacharoff, Alex C.; Durrie, Daniel S.; Aran, Alberto J.; Barnet, Ronald W.; Dulaney, David D.; Hurt, Art C., III; Mann, P. M.; Sawelson, Harold; Yanoff, Myron; Muller, David F.

    1994-06-01

    We update the continued progress of laser thermokeratoplasty (LTK) clinical trials being conducted in the U.S. for the treatment of hyperopia and hyperopic astigmatism. Data from the Phase II hyperopia investigations on 25 patients and from Phase I astigmatism trials on 30 patients is reviewed. From the hyperopia Phase IIa study, the near uncorrected visual acuity of 13 patients for whom complete follow-up results are available at 1 year shows that all 13 patients gained 2 or more lines of visual acuity (Ave. gain 3.5 lines), which indicates a significant improvement in near vision. A survey given to these hyperopia patients finds 8% could read without glasses preoperatively versus 58.3% at 1 year post-operatively. The preoperative uncorrected visual acuity of those patients treated for astigmatism in the Phase I trial showed 2 out of 30 patients or 6.7% seeing better than 20/40 versus 10 out of 27 patients or 37% at one year post-op. The one year data in both studies indicates that after an initial period of partial regression of effect, the residual correction remains relatively stable between 6 months and 1 year. Continued follow-up will be carried out to see if the corrections remain stable beyond 1 year.

  1. Laser intensity scaling through stimulated scattering in optical fibers

    NASA Astrophysics Data System (ADS)

    Russell, Timothy H.

    The influence of stimulated scattering on laser intensity in fiber optic waveguides is examined. Stimulated Brillouin scattering (SBS) in long, multimode optical waveguides is found to generate a Stokes beam that propagates in the fiber LP01 mode. This characteristic of the Stokes beam was first applied to beam cleanup, where an aberrated pump generated a Gaussian-like Stokes beam. Additionally, the same process is found to combine multiple laser beams into a single spatially coherent source. The mean square difference between the two beams was used to measure the degree of spatial overlap, demonstrating spatial coherence between the Stokes beams even when the pump beams are not spatially correlated. This result is obtained regardless of whether the pump beams are at the same or different frequencies; producing two temporally coherent or incoherent Stokes beams respectively. Limitations in beam cleanup and combining are also examined to identify ways to overcome them. Output couplers are designed that could be used to spatially filter the Stokes beam from the pump, thus increasing the number of beams that could be combined. The combined power restriction induced by second order Stokes threshold is examined experimentally and theoretically and is not found to be a significant limitation. Finally, stimulated Raman scattering (SRS) beam cleanup is examined to overcome the stringent spectral requirements on the pump beams required by SBS. The last portion of the dissertation theoretically examines suppression of stimulated Raman scattering in fibers to eliminate the restriction this imposes on the power of a fiber laser or amplifier. The suppression was modeled using both a holmium dopant and adding a long period grating to the fiber. Both methods were shown to have a significant effect on the SRS threshold.

  2. Minimally Invasive Surgical Ureterolithotomy Versus Ureteroscopic Lithotripsy for Large Ureteric Stones: A Systematic Review and Meta-analysis of the Literature.

    PubMed

    Kallidonis, Panagiotis; Ntasiotis, Panteleimon; Knoll, Thomas; Sarica, Kemal; Papatsoris, Athanasios; Somani, Bhaskar K; Greco, Francesco; Aboumarzouk, Omar M; Álvarez-Maestro, Mario; Sanguedolce, Francesco

    2017-12-01

    The management of large ureteric stones represents a technical and clinical challenge. To investigate the safety and efficacy of minimally invasive surgical ureterolithotomy (MISU) in comparison with ureteroscopic lithotripsy (URS) for the treatment of large ureteric stones. The Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) guidelines were followed for the conduction of the study, which was registered in the PROSPERO database. Search string was "(laparoscop* OR retroperito* OR robot*) AND ureterolitho*"; database scope included PubMed, SCOPUS, Cochrane, and EMBASE. Primary end points were the stone-free (SFR) and complications rates. Secondary end points included operative time and hospital stay. Subgroup analyses were performed for stones 1-2 and >2cm, as well as different lithotripters and ureteroscopes. Meta-analysis and forest-plot diagrams were performed with the RevMan 5.3.5 software. After screening 673 publications, seven randomized controlled trials were eligible to be included in the meta-analysis. A total of 778 patients were pooled after the elimination of the dropouts. No robotic cohorts were found. Only upper ureteral stones were treated in the included studies. The SFR at discharge and 3 mo was higher with MISU with odds ratios of 6.30 (95% confidence interval [CI]: 3.05, 13.01; I 2 =0%) and 5.34 (95% CI: 2.41, 8.81; I 2 =0%), respectively. The most common complications for MISU and URS were conversion to open surgery and stone migration to the renal pelvis, respectively. Favorable results in terms of operative time were observed in the case of URS with a mean difference of 29.5min (95% CI: 14.74, 44.26; I 2 =98%). Hospitalization time was favorable in the case of URS with a mean difference of 2.08 days (95% CI: 0.96, 3.20; I 2 =99%). This meta-analysis showed a significantly higher SFR at discharge and 3 mo for MISU in comparison with URS when upper ureteral stones were treated. Operative and hospitalization time favored URS over MISU. The current study investigated the literature on the minimally invasive management of large ureteric stones. The available evidence shows that both ureteroscopic lithotripsy and minimally invasive surgical ureterolithotomy could be considered for the treatment of these stones with similar results. The selection of the approach should be based on the advantages and disadvantages of each technique. Copyright © 2017 European Association of Urology. All rights reserved.

  3. Flexible ureterorenoscopy and laser lithotripsy in children

    PubMed Central

    Yeow, When-Chan; Pemberton, Richard; Barker, Andrew

    2009-01-01

    Background: Flexible ureterorenoscopy (FUR) and laser lithotripsy (LL) are techniques used in the management of upper urinary tract disorders. These techniques, so far established in adults, are now being used in children as well. We report our experience with 26 cases of pediatric upper urinary tract disorders treated using these techniques. Methods: In the period from 1997 to 2006, FUR was performed in 26 children (14 males and 12 females) in the age group of three months to 15 years with a mean age of 8.2 years. Twenty five were stented prior to undergoing FUR and 24 presented with suspected upper tract stones (17 pelvicalyceal and seven midureteric). Two cases showed JJ stent migration post-pyeloplasty. Results: Eight cases involved diagnostic procedures. Six excluded the presence of renal calculi, one had focal medullary sponge kidney, and one had calcified papillae. There were 15 cases of therapeutic FUR. Of these, 12 had LL with only one had incomplete stone fragmentation which subsequently passed spontaneously. Other therapeutic procedures included removal of migrated JJ stents and FUR with the basket removal of a midureteric calculus. Three cases failed ureterorenoscopy due to technical difficulties. The overall success rate was 88.5% for FUR. Conclusion: FUR and LL are valuable minimally invasive techniques for the examination and treatment of pediatric upper urinary tract conditions. Preoperative stenting improves passage of the ureteroscope and with progressive miniaturization of instruments, the lower weight limit will decrease. PMID:20671848

  4. Simple sonochemical synthesis of Ho2O3-SiO2 nanocomposites as an effective photocatalyst for degradation and removal of organic contaminant.

    PubMed

    Zinatloo-Ajabshir, Sahar; Mortazavi-Derazkola, Sobhan; Salavati-Niasari, Masoud

    2017-11-01

    In this work, highly photocatalytically active Ho 2 O 3 -SiO 2 nanocomposites have been designed and applied for decomposition of methylene blue pollutant. Ho 2 O 3 -SiO 2 nanocomposites have been produced by new, quick and facile sonochemical process with the aid of tetramethylethylenediamine as a novel basic agent for the first time. The effect of the kind of basic agent, ultrasonic time and dosage of Ho source on the grain size, photocatalytic behavior and shape of the Ho 2 O 3 -SiO 2 nanocomposites have been evaluated for optimization the production condition. FESEM, EDX, FT-IR, DRS, XRD and TEM have been applied to characterize the as-produced Ho 2 O 3 -SiO 2 nanocomposites. Use of the as-produced Ho 2 O 3 -SiO 2 nanocomposites as photocatalyst via destruction of methylene blue pollutant under UV illumination has been compared. It was observed that SiO 2 has notable impact on catalytic activity of holmium oxide photocatalyst for destruction. Introducing of SiO 2 to holmium oxide can enhance destruction efficiency of holmium oxide to methylene blue pollutant under ultraviolet light. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Clinical effects of transcatheter hepatic arterial embolization with holmium-166 poly(l-lactic acid) microspheres in healthy pigs

    PubMed Central

    Nijsen, J. F. W.; de Wit, T. C.; Seppenwoolde, J. H.; Krijger, G. C.; Seevinck, P. R.; Huisman, A.; Zonnenberg, B. A.; van den Ingh, T. S. G. A. M.; van het Schip, A. D.

    2008-01-01

    Purpose The aim of this study is to evaluate the toxicity of holmium-166 poly(l-lactic acid) microspheres administered into the hepatic artery in pigs. Methods Healthy pigs (20–30 kg) were injected into the hepatic artery with holmium-165-loaded microspheres (165HoMS; n = 5) or with holmium-166-loaded microspheres (166HoMS; n = 13). The microspheres’ biodistribution was assessed by single-photon emission computed tomography and/or MRI. The animals were monitored clinically, biochemically, and (166HoMS group only) hematologically over a period of 1 month (165HoMS group) or over 1 or 2 months (166HoMS group). Finally, a pathological examination was undertaken. Results After microsphere administration, some animals exhibited a slightly diminished level of consciousness and a dip in appetite, both of which were transient. Four lethal adverse events occurred in the 166HoMS group due either to incorrect administration or comorbidity: inadvertent delivery of microspheres into the gastric wall (n = 2), preexisting gastric ulceration (n = 1), and endocarditis (n = 1). AST levels were transitorily elevated post-166HoMS administration. In the other blood parameters, no abnormalities were observed. Nuclear scans were acquired from all animals from the 166HoMS group, and MRI scans were performed if available. In pigs from the 166HoMS group, atrophy of one or more liver lobes was frequently observed. The actual radioactivity distribution was assessed through ex vivo 166mHo measurements. Conclusion It can be concluded that the toxicity profile of HoMS is low. In pigs, hepatic arterial embolization with 166HoMS in amounts corresponding with liver-absorbed doses of over 100 Gy, if correctly administered, is not associated with clinically relevant side effects. This result offers a good perspective for upcoming patient trials. PMID:18330569

  6. Laser fiber cleaving techniques: effects on tip morphology and power output.

    PubMed

    Vassantachart, Janna M; Lightfoot, Michelle; Yeo, Alexander; Maldonado, Jonathan; Li, Roger; Alsyouf, Muhannad; Martin, Jacob; Lee, Michael; Olgin, Gaudencio; Baldwin, D Duane

    2015-01-01

    Proper cleaving of reusable laser fibers is needed to maintain optimal functionality. This study quantifies the effect of different cleaving tools on power output of the holmium laser fiber and demonstrates morphologic changes using microscopy. The uncleaved tips of new 272 μm reusable laser fibers were used to obtain baseline power transmission values at 3 W (0.6 J, 5 Hz). Power output for each of four cleaving techniques-11-blade scalpel, scribe pen cleaving tool, diamond cleaving wheel, and suture scissors-was measured in a single-blinded fashion. Dispersion of light from the fibers was compared with manufacturer specifications and rated as "ideal," "acceptable," or "unacceptable" by blinded reviewers. The fiber tips were also imaged using confocal and scanning electron microscopy. Independent samples Kruskal-Wallis test and chi square were used for statistical analysis (α<0.05). New uncleaved fiber tips transmitted 3.04 W of power and were used as a reference (100%). The scribe pen cleaving tool produced the next highest output (97.1%), followed by the scalpel (83.4%), diamond cleaving wheel (77.1%), and suture scissors (61.7%), a trend that was highly significant (P<0.001). On pairwise comparison, no difference in power output was seen between the uncleaved fiber tips and those cleaved with the scribe pen (P=1.0). The rating of the light dispersion patterns from the different cleaving methods followed the same trend as the power output results (P<0.001). Microscopy showed that the scribe pen produced small defects along the fiber cladding but maintained a smooth, flat core surface. The other cleaving techniques produced defects on both the core and cladding. Cleaving techniques produce a significant effect on the initial power transmitted by reusable laser fibers. The scribe pen cleaving tool produced the most consistent and highest average power output.

  7. Calculus migration characterization during Ho:YAG laser lithotripsy by high-speed camera using suspended pendulum method.

    PubMed

    Zhang, Jian James; Rajabhandharaks, Danop; Xuan, Jason Rongwei; Chia, Ray W J; Hasenberg, Thomas

    2017-07-01

    Calculus migration is a common problem during ureteroscopic laser lithotripsy procedure to treat urolithiasis. A conventional experimental method to characterize calculus migration utilized a hosting container (e.g., a "V" grove or a test tube). These methods, however, demonstrated large variation and poor detectability, possibly attributed to the friction between the calculus and the container on which the calculus was situated. In this study, calculus migration was investigated using a pendulum model suspended underwater to eliminate the aforementioned friction. A high-speed camera was used to study the movement of the calculus which covered zero order (displacement), first order (speed), and second order (acceleration). A commercialized, pulsed Ho:YAG laser at 2.1 μm, a 365-μm core diameter fiber, and a calculus phantom (Plaster of Paris, 10 × 10 × 10 mm 3 ) was utilized to mimic laser lithotripsy procedure. The phantom was hung on a stainless steel bar and irradiated by the laser at 0.5, 1.0, and 1.5 J energy per pulse at 10 Hz for 1 s (i.e., 5, 10, and 15 W). Movement of the phantom was recorded by a high-speed camera with a frame rate of 10,000 FPS. The video data files are analyzed by MATLAB program by processing each image frame and obtaining position data of the calculus. With a sample size of 10, the maximum displacement was 1.25 ± 0.10, 3.01 ± 0.52, and 4.37 ± 0.58 mm for 0.5, 1, and 1.5 J energy per pulse, respectively. Using the same laser power, the conventional method showed <0.5 mm total displacement. When reducing the phantom size to 5 × 5 × 5 mm 3 (one eighth in volume), the displacement was very inconsistent. The results suggested that using the pendulum model to eliminate the friction improved sensitivity and repeatability of the experiment. A detailed investigation on calculus movement and other causes of experimental variation will be conducted as a future study.

  8. Energy Delivery Systems for Treatment of Benign Prostatic Hyperplasia

    PubMed Central

    2006-01-01

    Executive Summary Objective The Ontario Health Technology Advisory Committee asked the Medical Advisory Secretariat (MAS) to conduct a health technology assessment on energy delivery systems for the treatment of benign prostatic hyperplasia (BPH). Clinical Need: Target Population and Condition BPH is a noncancerous enlargement of the prostate gland and the most common benign tumour in aging men. (1) It is the most common cause of lower urinary tract symptoms (LUTS) and bladder outlet obstruction (BOO) and is an important cause of diminished quality of life among aging men. (2) The primary goal in the management of BPH for most patients is a subjective improvement in urinary symptoms and quality of life. Until the 1930s, open prostatectomy, though invasive, was the most effective form of surgical treatment for BPH. Today, the benchmark surgical treatment for BPH is transurethral resection of the prostate (TURP), which produces significant changes of all subjective and objective outcome parameters. Complications after TURP include hemorrhage during or after the procedure, which often necessitates blood transfusion; transurethral resection (TUR) syndrome; urinary incontinence; bladder neck stricture; and sexual dysfunction. A retrospective review of 4,031 TURP procedures performed by one surgeon between 1979 and 2003 showed that the incidence of complications was 2.4% for blood transfusion, 0.3% for TUR syndrome, 1.5% for hemostatic procedures, 2.8% for bladder neck contracture, and 1% for urinary stricture. However, the incidence of blood transfusion and TUR syndrome decreased as the surgeon’s skills improved. During the 1990s, a variety of endoscopic techniques using a range of energy sources have been developed as alternative treatments for BPH. These techniques include the use of light amplification by stimulated emission of radiation (laser), radiofrequency, microwave, and ultrasound, to heat prostate tissue and cause coagulation or vaporization. In addition, new electrosurgical techniques that use higher amounts of energy to cut, coagulate, and vaporize prostatic tissue have entered the market as competitors to TURP. The driving force behind these new treatment modalities is the potential of producing good hemostasis, thereby reducing catheterization time and length of hospital stay. Some have the potential to be used in an office environment and performed under local anesthesia. Therefore, these new procedures have the potential to rival TURP if their effectiveness is proven over the long term. The Technology Being Reviewed The following energy-based techniques were considered for assessment: transurethral electrovaporization of the prostate (TUVP) transurethral electrovapor resection of the prostate (TUVRP) transurethral electrovaporization of the prostate using bipolar energy (plasmakinetic vaporization of the prostate [PKVP]) visual laser ablation of the prostate (VLAP) transurethral ultrasound guided laser incision prostatectomy (TULIP) contact laser vaporization of the prostate (CLV) interstitial laser coagulation (ILC) holmium laser resection of the prostate (HoLRP) holmium laser enucleation of the prostate (HoLEP) holmium laser ablation of the prostate (HoLAP) potassium titanyl phosphate (KTP) laser transurethral microwave thermotherapy (TUMT) transurethral needle ablation (TUNA) Review Strategy A search of electronic databases (OVID MEDLINE, MEDLINE In-Process & Other Non-Indexed Citations, EMBASE, The Cochrane Library, and the International Agency for Health Technology Assessment [INAHTA] database) was undertaken to identify evidence published from January 1, 2000 to June 21, 2006. The search was limited to English-language articles and human studies. The literature search identified 284 citations, of which 38 randomized controlled trials (RCTs) met the inclusion criteria. Since the application of high-power (80 W) KTP laser (photoselective vaporization of the prostate [PVP]) has been supported in the United States and has resulted in a rapid diffusion of this technology in the absence of any RCTs, the MAS decided that any comparative studies on PVP should be identified and evaluated. Hence, the literature was searched and one prospective cohort study (3) was identified but evaluated separately. Findings of Literature Review and Analysis Meta-analysis of the results of RCTs shows that monopolar electrovaporization is as clinically effective as TURP for the relief of urinary symptoms caused by BPH (based on 5-year follow-up data). Meta-analysis of the results of RCTs shows that bipolar electrovaporization (PKVP) is clinically as effective as TURP for the relief of urinary symptoms caused by BPH (based on 1-year follow-up data). Two of the three RCTs on VLAP have shown that patients undergoing VLAP had a significantly lesser improvement in urinary symptom scores compared with patients undergoing TURP. RCTs showed that the time to catheter removal was significantly longer in patients undergoing VLAP compared with patients undergoing TURP. Meta-analysis of the rate of reoperation showed that patients undergoing VLAP had a significantly higher rate of reoperation compared with patients undergoing TURP. Meta-analysis showed that patients undergoing CLV had a significantly lesser improvement in urinary symptom scores compared with TURP at 2 years and at 3 or more years of follow-up. Two RCTs with 6-month and 2-year follow-up showed similar improvement in symptom scores for ILC and TURP. Time to catheter removal was significantly longer in patients undergoing ILC compared with patients undergoing TURP. The results of RCTs on HoLEP with 1-year follow-up showed excellent clinical outcomes with regard to the urinary symptom score and peak urinary flow. Meta-analysis showed that at 1-year follow-up, patients undergoing HoLEP had a significantly greater improvement in urinary symptom scores and peak flow rate compared with patients undergoing TURP. Procedural time is significantly longer in HoLEP compared with TURP. The results of one RCT with 4-year follow-up showed that HoLRP and TURP provided equivalent improvement in urinary symptom scores. The results of one RCT with 1-year follow-up showed that patients undergoing KTP had a lesser improvement in urinary symptom scores than did patients undergoing TURP. However, the results were not significant at longer-term follow-up periods. Two RCTs that provided 3-year follow-up data reported that patients undergoing TUMT had a significantly lesser improvement in symptom score compared with patients undergoing TURP. RCTs reported a longer duration of catheterization for TUMT compared with TURP (P values are not reported). The results of a large RCT with 5-year follow-up showed a significantly lesser improvement in symptom scores in patients undergoing TUNA compared with patients undergoing TURP. Meta-analysis of the rate of reoperation showed that patients undergoing TUNA had a significantly higher rate of reoperation compared with patients undergoing TURP. Based on the results of RCTs, TURP is associated with a 0.5% risk of TUR syndrome, while no cases of TUR syndrome have been reported in patients undergoing monopolar or bipolar electrovaporization, laser-based procedures, TUMT, or TUNA. Based on the results of RCTs, the rate of blood transfusion ranges from 0% to 8.3% in patients undergoing TURP. The rate is about 1.7% in monopolar electrovaporization, 1.4% in bipolar electrovaporization, and 0.4% in the VLAP procedure. No patients undergoing CLV, ILC, HoLEP, HoLRP, KTP, TUMT, and TUNA required blood transfusion. The mean length of hospital stay is between 2 and 5 days for patients undergoing TURP, about 3 days for electrovaporization, about 2 to 4 days for Nd:YAG laser procedures, and about 1 to 2 days for holmium laser procedures. TUMT and TUNA can each be performed as a day procedure in an outpatient setting (0.5 and 1 day respectively). Based on a prospective cohort study, PVP is clinically as effective as TURP for the relief of urinary symptoms caused by BPH (based on 6-month follow-up data). Time to catheter removal was significantly shorter in patients undergoing PVP than in those undergoing TURP. Operating room time was significantly longer in PVP than in TURP. PVP has the potential to reduce health care expenses due to shorter hospital stays. Economic Analysis In the three most recent fiscal years (FY) reported, an average of approximately 5,000 TURP procedures per year were performed in Ontario. From FY 2002 to FY 2004, the total number of surgical interventions decreased by approximately 500 procedures. During this time, the increase in costs of drugs to the government was estimated at approximately $10 million (Cdn); however, there was a concurrent decrease in costs due to a decline in the total number of surgical procedures, estimated at approximately $1.9 million (Cdn). From FY 2002 to FY 2004, the increase in costs associated with the increase in utilization of drugs for the treatment of BPH translates into $353 (Cdn) per patient while the cost savings associated with a decrease in the total number of surgical procedures translates into a savings of $3,906 (Cdn) per patient. The following table summarizes the change in the current budget, depending on various estimates of the total percentage of the 5,000 TURP procedures that might be replaced by other energy-based interventions for the treatment of BPH in the future. Executive Summary Table 1: Budget Impact With Various Estimates of the Percentage of TURP Procedures Captured by Energy-based Interventions for the Treatment of BPH Technology Cost perprocedure, $ Budget Impact of 25% diffusion, $M Budget Impact of 50% diffusion, $M Budget Impact of 75% diffusion, $M Budget Impact of 100% diffusion, $M Incremental Budget Impact, $M TURP 3,887 19.4 Bipolar Electrovaporization 4,011 19.6 19.7 19.9 20.0 0.6 Monopolar Electrovaporization 4,130 19.7 20.0 20.3 20.6 1.2 TUMT 1,529 16.5 13.5 10.6 7.6 (11.8)  TUNA 4,804 20.6 21.7 22.9 24.0 4.6 PVP 1,184 16.0 12.7 9.3 5.9 (13.5)   Holmium Laser 3,892 19.4 19.4 19.4 19.4 0.02 VLAP Nd:YAG 4,663 20.4 21.4 22.3 23.3 3.9 CLAP Nd:YAG 4,615 20.3 21.2 22.4 23.0 3.6 * All costs are in Canadian currency. Parentheses indicative of cost reduction. PMID:23074487

  9. Gamma spectrometry and chemical characterization of ceramic seeds with samarium-153 and holmium-166 for brachytherapy proposal.

    PubMed

    Valente, Eduardo S; Campos, Tarcísio P R

    2010-12-01

    Ceramic seeds were synthesized by the sol-gel technique with Si:Sm:Ca and Si:Ho:Ca. One set of seeds was irradiated in the TRIGA type nuclear reactor IPR-R1 and submitted to instrumental neutron activation analysis (INAA), K(0) method, to determine mass percentage concentration of natural samarium and holmium in the seed as well as to determine all existing radionuclides and their activities. Attention was paid to discrimination of Si-31, Ca-40, Ca-45, Ca-47, Ca-49, Sm-145, Sm-155, Sm-153 and Ho-166. A second sample was submitted to atomic emission spectrometry (ICP-AES) also to determine samarium and holmium concentrations in weight. A third sample was submitted to X-ray fluorescence spectrometry to qualitatively determine chemical composition. The measured activity was due to Sm-153 and Ho-166 with a well-characterized gamma spectrum. The X-ray fluorescence spectrum demonstrated that there is no discrepancy in seed composition. The maximum ranges in the water of beta particles from Sm-153 and Ho-166 decay were evaluated, as well as the dose rate and total dose delivered within the volume delimited by the range of the beta particles. The results are relevant for investigation of the viability of producing Sm-153 and Ho-166 radioactive seeds for use in brachytherapy. Copyright 2010 Elsevier Ltd. All rights reserved.

  10. Durability of Flexible Ureteroscopes: A Prospective Evaluation of Longevity, the Factors that Affect it, and Damage Mechanisms.

    PubMed

    Legemate, Jaap D; Kamphuis, Guido M; Freund, Jan Erik; Baard, Joyce; Zanetti, Stefano P; Catellani, Michele; Oussoren, Harry W; de la Rosette, Jean J

    2018-03-10

    Flexible ureteroscopy is an established treatment modality for evaluating and treating abnormalities in the upper urinary tract. Reusable ureteroscope (USC) durability is a significant concern. To evaluate the durability of the latest generation of digital and fiber optic reusable flexible USCs and the factors affecting it. Six new flexible USCs from Olympus and Karl Storz were included. The primary endpoint for each USC was its first repair. Data on patient and treatment characteristics, accessory device use, ureteroscopy time, image quality, USC handling, disinfection cycles, type of damage, and deflection loss were collected prospectively. Ureteroscopy. USC durability was measured as the total number of uses and ureteroscopy time before repair. USC handling and image quality were scored. After every procedure, maximal ventral and dorsal USC deflection were documented on digital images. A total of 198 procedures were performed. The median number of procedures was 27 (IQR 16-48; 14h) for the six USCs overall, 27 (IQR 20-56; 14h) for the digital USCs, and 24 (range 10-37; 14h) for the fiber optic USCs. Image quality remained high throughout the study for all six USCs. USC handling and the range of deflection remained good under incremental use. Damage to the distal part of the shaft and shaft coating was the most frequent reason for repair, and was related to intraoperative manual forcing. A limitation of this study is its single-center design. The durability of the latest reusable flexible USCs in the current study was limited to 27 uses (14h). Damage to the flexible shaft was the most important limitation to the durability of the USCs evaluated. Prevention of intraoperative manual forcing of flexible USCs maximizes their overall durability. Current flexible ureteroscopes proved to be durable. Shaft vulnerability was the most important limiting factor affecting durability. Copyright © 2018 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  11. Benign Prostatic Hyperplasia: from Bench to Clinic

    PubMed Central

    Cho, Hee Ju

    2012-01-01

    Benign prostatic hyperplasia (BPH) is a prevalent disease, especially in old men, and often results in lower urinary tract symptoms (LUTS). This chronic disease has important care implications and financial risks to the health care system. LUTS are caused not only by mechanical prostatic obstruction but also by the dynamic component of obstruction. The exact etiology of BPH and its consequences, benign prostatic enlargement and benign prostatic obstruction, are not identified. Various theories concerning the causes of benign prostate enlargement and LUTS, such as metabolic syndrome, inflammation, growth factors, androgen receptor, epithelial-stromal interaction, and lifestyle, are discussed. Incomplete overlap of prostatic enlargement with symptoms and obstruction encourages focus on symptoms rather than prostate enlargement and the shifting from surgery to medicine as the treatment of BPH. Several alpha antagonists, including alfuzosin, doxazosin, tamsulosin, and terazosin, have shown excellent efficacy without severe adverse effects. In addition, new alpha antagonists, silodosin and naftopidil, and phosphodiesterase 5 inhibitors are emerging as BPH treatments. In surgical treatment, laser surgery such as photoselective vaporization of the prostate and holmium laser prostatectomy have been introduced to reduce complications and are used as alternatives to transurethral resection of the prostate (TURP) and open prostatectomy. The status of TURP as the gold standard treatment of BPH is still evolving. We review several preclinical and clinical studies about the etiology of BPH and treatment options. PMID:22468207

  12. Room temperature high power mid-IR diode laser bars for atmospheric sensing applications

    NASA Astrophysics Data System (ADS)

    Crump, Paul; Patterson, Steve; Dong, Weimin; Grimshaw, Mike; Wang, Jun; Zhang, Shiguo; Elim, Sandrio; Bougher, Mike; Patterson, Jason; Das, Suhit; Wise, Damian; Matson, Triston; Balsley, David; Bell, Jake; DeVito, Mark; Martinsen, Rob

    2007-04-01

    Peak CW optical power from single 1-cm diode laser bars is advancing rapidly across all commercial wavelengths and the available range of emission wavelengths also continues to increase. Both high efficiency ~ 50% and > 100-W power InP-based CW bars have been available in bar format around 1500-nm for some time, as required for eye-safe illuminators and for pumping Er-YAG crystals. There is increasing demand for sources at longer wavelengths. Specifically, 1900-nm sources can be used to pump Holmium doped YAG crystals, to produce 2100-nm emission. Emission near 2100-nm is attractive for free-space communications and range-finding applications as the atmosphere has little absorption at this wavelength. Diode lasers that emit at 2100-nm could eliminate the need for the use of a solid-state laser system, at significant cost savings. 2100-nm sources can also be used as pump sources for Thulium doped solid-state crystals to reach even longer wavelengths. In addition, there are several promising medical applications including dental applications such as bone ablation and medical procedures such as opthamology. These long wavelength sources are also key components in infra-red-counter-measure systems. We have extended our high performance 1500-nm material to longer wavelengths through optimization of design and epitaxial growth conditions and report peak CW output powers from single 1-cm diode laser bars of 37W at 1910-nm and 25W at 2070-nm. 1-cm bars with 20% fill factor were tested under step-stress conditions up to 110-A per bar without failure, confirming reasonable robustness of this technology. Stacks of such bars deliver high powers in a collimated beam suitable for pump applications. We demonstrate the natural spectral width of ~ 18nm of these laser bars can be reduced to < 3-nm with use of an external Volume Bragg Grating, as required for pump applications. We review the developments required to reach these powers, latest advances and prospects for longer wavelength, higher power and higher efficiency.

  13. [Use of laser in arthroscopy of the ankle. Indications, method, first results].

    PubMed

    Zangger, P; Gerber, B E

    1996-02-01

    As in the knee joint, lasers can be used during ankle arthroscopy for their resective and ablative properties. Reports on arthroscopic treatment of degenerative and post-traumatic disorder of the ankle by conventional techniques are encouraging. We have used laser in ankle arthroscopy in three main situations: (1) When exuberant scar tissue from previous capsulo-ligamentous damage (e.g. after ankle sprain) symptomatically restricts range of motion and causes pain (ankle impingement). Laser is used in this case at middle energy, as a resector. (2) In the presence of cartilaginous lesions, as in osteoarthritis, flake fractures or osteoarthritis, flake fractures or osteochondrosis dissecans. Here laser is used at lower energy to reshape the cartilaginous surface without resective effect ("welding"). (3) When impaired range of motion is due to osteophytic rims, mainly at the anterior tibia, resulting from previous capsular lesions. Laser is then used at high energy to cut excessive bone. A series of 16 patients underwent ankle arthroscopy at our clinic, mainly for post-traumatic disorders, including impingement, osteochondrosis dissecans and osteoarthritis. The most frequently encountered intraarticular findings were impingement by post-traumatic synovitis and scar tissue of the anterio-lateral and postero-lateral compartments, with or without an osteophytic rim of the distal anterior tibial border. Scar tissue, synovitis and osteophytes were debrided in half of the patients purely mechanically (with arthroscopic scissors or shaver) and in the other half with the holmium laser. The results are encouraging; 50% of patients had no symptoms at all at follow-up (9.5 months on average), and another 38% were satisfied with a significant improvement. In two cases, no improvement at all occurred: one patient complained of persistent pain with lack of objective findings and is believed to have developed "insurance neurosis." The other had severe postinfectious osteoarthritis that was operated too late in the course to influence pain positively. Concerning the clinical, functional and subjective follow-up results there was no relevant difference between the two groups. We recommend ankle arthroscopy to treat post-traumatic impingement syndromes of the antero-lateral, antero-medial and postero-lateral compartments of the ankle joint; the use of lasers seems to have a slightly better analgetic effect, allows an easier approach than is the case with shavers or other bulky arthroscopic resectors, and allows shaping of convex resection surfaces, which cannot be performed with a shaver.

  14. The PolyScope: a modular design, semidisposable flexible ureterorenoscope system.

    PubMed

    Bader, Markus Juergen; Gratzke, Christian; Walther, Sebastian; Schlenker, Boris; Tilki, Derya; Hocaoglu, Yasemin; Sroka, Ronald; Stief, Christian Georg; Reich, Oliver

    2010-07-01

    To characterize the mechanical and optical properties of the PolyScope endoscope system and to examine the clinical outcome in patients who were undergoing ureteronephroscopy. Mechanical assessment involved measurement of the deflection angle and irrigation flow rate. Optical resolution and distortion, field and angle of view, and light transmission and output formed the optical assessment. Clinical assessment was made in a series of consecutive ureteronephroscopy procedures. The optical cord was disconnected after each procedure, and the image fiber was assessed for damage. The mean value for the angle of maximum active tip deflection with an empty working channel was 265 degrees (261-275 degrees). Deflection was impaired most with insertion of the 3.0 F basket (10% decrease) and least with an indwelling 220 microm laser fiber (2% decrease). Irrigation flow rate was 57 mL/min with an empty working channel. Flow was reduced by 50% and 68%, with the insertion of a 200 microm or 365 microm laser probe, respectively, and by 92.5% with a 3.2F basket. No damage to the image fiber occurred. The PolyScope optics system could identify a target of about 0.125 mm at a distance of 2 to 4 mm, based on 3 line-pairs/mm needed for clear identification. Lithotripsy of renal calculi was performed for 40 stone burdens in 32 patients; the resulting stone-free rate was 87.5%. The novel semidisposable ureteroscope system PolyScope was simple to use, effective, and reliable in this preliminary clinical evaluation. It overcomes the inherent fragility of comparable devices, which renders the need for maintenance unnecessary.

  15. Synthesis and optical properties of antimony oxide glasses doped with holmium trioxide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raghunatha, S.; Eraiah, B., E-mail: eraiah@rediffmail.com

    2016-05-06

    Holmium doped lithium-antimony-lead borate glasses having 1 mol% AgNO{sub 3} with composition 50B{sub 2}O{sub 3}-20PbO-25Sb{sub 2}O{sub 3}-5Li{sub 2}O have been prepared using single step melt quenching technique. The XRD spectrum confirms amorphous nature of glasses. The optical absorbance studies were carried out on these glasses. The optical direct band gap energies were found to be in the range of 3.10 eV to 3.31 eV and indirect band gap energies were found to be in the range of 2.28 eV to 3.00 eV. The refractive indexes have been calculated by using Lorentz-Lorenz formula and the calculated values in the range ofmore » 2.31 to 2.37.« less

  16. Magnetic suspension and balance system advanced study, phase 2

    NASA Technical Reports Server (NTRS)

    Boom, R. W.; Abdelsalam, M. K.; Eyssa, Y. M.; Mcintosh, G. E.

    1990-01-01

    The design improvements for the system encompass 14 or 18 external superconductive coils mounted on a 8 x 8 foot wind tunnel, a superconductive model core magnet on a holmium mandrel to fit an F-16 model, model wings of permanent magnet material Nd2Fe14B, and fiber glass epoxy structure. The Magnetic Suspension and Balance System (MSBS) advanced design is confirmed by the successful construction and test of a full size superconductive model core solenoid with holmium mandrel. The solenoid is 75 cm long and 12.6 cm in diameter and produces 6.1 tesla for a hold time of 47 minutes. An integrated coil system design of a new compact configuration without specific coils for roll or pitch shows promise of simplicity; magnet reductions of 30 percent compared to the most recent 1985 design are possible.

  17. Optical and Physical Investigations of Lanthanum Bismuth Borate glasses doped with Ho2O3

    NASA Astrophysics Data System (ADS)

    Ramesh, P.; Jagannath, G.; Eraiah, B.; Kokila, M. K.

    2018-02-01

    Holmium doped 10La2O3-15Bi2O3-(75-x) B2O3 (Ho3+: LBB) glasses have been prepared by melt quench technique and the impact of holmium ions concentration on optical and physical properties of present glasses have been examined. Ho3+ dependent density, molar volume, refractive index, rare earth ion concentration, polaron radius, inter ionic distance, field strength and energy band gap are calculated and tabulated. Amorphous nature of the all glasses has been confirmed by XRD patterns. The room temperature (RT) Uv-Vis absorption spectrum doped with 1 mol% of Ho2O3 exhibit eight prominent bands centred at 895, 641, 537, 486, 472, 467, 451 and 416 due to transition between ground state to various excited states. The results show that, the density is increases and molar volume of the glasses is decreases with an increase in Ho2O3 concentration and consequently generate more non-bridging oxygen (NBOs) in the glass matrix. The Urbach energy is increases with holmium concentration which exemplifies the degree of disorder present in the LBB glasses. The considerable increase in field strength observed in present glasses is attributed to occurrence of strong bridge between Ho3+ and B- ions and this strong bridge is possibly due to the displacement between Ho3+ and oxygen atoms which are generated from the conversion BO3-BO4 units.

  18. Usage of GreenLight HPS 180-W laser vaporisation for treatment of benign prostatic hyperplasia.

    PubMed

    Jovanović, M; Džamić, Z; Aćimović, M; Kajmaković, B; Pejčić, T

    2014-01-01

    Laser therapy has gained increasing acceptance as a relatively less invasive treatment for lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH). From the early procedure of interstitial laser coagulation through to the use of holmium laser enucleation of the prostate, there has been an expanding body of evidence on the efficacy of such procedures. One of the newer lasers is the Green Light HPS 180 W laser. Studies with this GreenLight laser (GLL) (American Medical Systems, Inc, Minnetonka, MN, USA) showing results as good as those of transurethral resection of the prostate (TURP). In this paper, the efficacy of the new GLL 180-W versus the gold standard TURP in patients with LUTS due to BPH was tested in a prospective clinical trial. To compare results of Green light laser (GLL) evaporisation of the prostatae and transurethral resection of the prostate (TURP) for treatment of BPH. MATERIJALS AND METHODS: A total of 62 patients with BPH were randomly assigned to two equal groups: TURP or GLL. Both groups were compared regarding all relevant preoperative, operative, and postoperative parameters. Functional results in terms of improvement of International Prostate Symptom Score (IPSS), maximum flow rate (Qmax), and postvoid residual (PVR) urine were assessed at 1, 3, 6 and 12 mo. A total of 62 patients completed 12 mo of follow-up in the TURP and GLL groups, respectively. Baseline characteristics were comparable. Mean operative time was significantly shorter for TURP. Compared to preoperative values, there was significant reduction in hemoglobin levels at the end of TURP only. A significant difference in favor of GLL was achieved regarding the duration of catheterization and hospital stay. In the GLL, no major intraoperative complications were recorded and none of the patients required blood transfusion. Among TURP patients, 6 required transfusion, 1 developed TUR syndrome, and capsule perforation was observed in 5 patients. There was dramatic improvement in Qmax, IPSS, and GLL compared with preoperative values and the degree of improvement was comparable in both groups at all time points of follow-up. Four TURP patients and one GLL patients developed bladder neck contracture treated by bladder neck incision; none in either group experienced urethral stricture or urinary incontinence. Compared to transurethral resection of the prostate, GreenLight HPS 180-W laser photoselective vaporization of the prostate is safe and effective in the treatment of patients suffering from lower urinary tract symptoms due to benign prostatic hyperplasia.

  19. Pulsed lasers in dentistry: sense or nonsense?

    NASA Astrophysics Data System (ADS)

    Koort, Hans J.; Frentzen, Matthias

    1991-05-01

    The great interest in the field of laser applications in dentistry provokes the question, if all these new techniques may really fulfill advantages, which are expected after initial in-vitro studies. Whereas laser surgery of soft oral tissues has been developed to a standard method, laser treatment of dental hard tissues and the bone are attended with many unsolved problems. Different laser types, especially pulsed lasers in a wide spectrum of wavelengths have been proofed for dental use. Today neither the excimer lasers, emitting in the far uv-range from 193 to 351 nm, nor the mid-infrared lasers like Nd:YAG (1,064 μm), Ho:YAG (2,1 μm) and Er:YAG (2,96 μm) or the C02-laser (10,6 μm) show mechanism of interaction more carefully and faster than a preparation of teeth with diamond drillers. The laser type with the most precise and considerate treatment effects in the moment is the short pulsed (15 ns) ArF-excimer laser with a wavelength of 193 nm. However this laser type has not yet the effectivity of mechanical instruments and it needs a mirror system to deliver the radiation. Histological results point out, that this laser shows no significant pathological alterations in the adjacent tissues. Another interesting excimer laser, filled with XeCI and emitting at a wavelength of 308 nm has the advantage to be good to deliver through quartz fibers. A little more thermal influence is to be seen according to the longer wavelength. Yet the energy density, necessary to cut dental hard tissues will not be reached with the laser systems available now. Both the pulsed Er:YAG- (2,94 μm, pulse duration 250 s) and the Ho:YAG -laser (2,1 μm, pulse duration 250 μs) have an effective coupling of the laser energy to hydrogeneous tissues, but they do not work sufficient on healthy enamel and dentine. The influence to adjacent healthy tissue is not tolerable, especially in regard of the thermal damage dentine and pulp tissues. Moreover, like the 193 nm ArF-excimer laser radiation the Er:YAG-laser radiation could also only be delivered via mirror systems, while the radiation of the Ho:YAG-Laser can be well transmitted through quartz fibers. The energy of the well known and in other medical disciplines often used Nd:YAG - laser (1,064 μm, pulse duration 150 us) laser can be transmitted through fiber systems without problems, but this laser has not the effectivity to work sufficient on healthy hard dental tissues due to the high transmission in mineralized dental tissues. The thermal injuries of this laser type are not tolerable. The short pulsed TEA-C02-laser (9,6 and 10,6 μm, pulse duration 200-300 ns), which has an excellent coupling not only to the hydrogeneous tissues but also to the mineralized tissues could be an alternative system to prepare dental tissues. The greatest disadvantage of this system is the noneffective delivery of the light energy through flexible fiber systems, which are still in development. Another good chance perhaps will have the q-switched Neodym, Erbium and Holmium:- YAG lasers with pulse durations of about some hundred ns. Both, possible thermal influences and possible disruptive effects should be small enough to let the adjacent tissues undamaged.

  20. Case series: Bladder clot evacuation using a prostate morcellation device.

    PubMed

    Doersch, Karen M; Navetta, Andrew F; Bird, Erin T; El Tayeb, Marawan M

    2017-07-01

    We sought to provide a technical update on the use of a prostate morcellator device (PMD) to manage organized blood clots of the bladder following laser prostatectomy. Herein, we describe our experience in using the Wolf Piranha morcellator in managing organized bladder blood clots supplemented with a retrospective chart review of the patients in whom this procedure was performed. Six patients, all male with a mean age of 75 ± 8.9 years, had organized bladder clots following either holmium laser enucleation or photoselective vaporization of the prostate managed with a PMD. Clots were recognized based on hematuria or urinary retention a median of 3.5 days following the aforementioned procedures. Initial management was attempted with more conservative measures, including a three-way Foley catheter, followed by cystoscopy with an Ellik evacuator, or a glass Tommey syringe. Morcellation times were a mean of 10.2 ± 6.15 minutes (range 2-18). This technique was able to manage clots that were an average of 173.3 ± 115.9 cc in size. The procedure was well-tolerated. No patients experienced intraoperative or morcellator-related complications. Benign prostatic hypertrophy frequently requires surgical endoscopic management and can be complicated by hematuria and bladder blood clot formation. When these clots become organized, this can lead to urinary retention and the required management, evacuation, may be difficult. The use of a Wolf Piranha PMD is a safe, well-tolerated, and effective in evacuating organized blood clots of the bladder.

  1. Impact of loop-tail ureteral stents on ureteral stent-related symptoms immediately after ureteroscopic lithotripsy: Comparison with pigtail ureteral stents

    PubMed Central

    Inoue, Takaaki; Muguruma, Kouei; Murota, Takashi; Kinoshita, Hidefumi; Matsuda, Tadashi

    2017-01-01

    Purpose To evaluate urination-related quality of life (QoL) in patients with an indwelling ureteral stent immediately after ureteroscopic lithotripsy (URSL) for upper urinary calculi. We compared the effects of loop-tail and pigtail ureteral stents on urination-related QoL. Materials and Methods Of 135 patients who underwent URSL between May 2014 and March 2015 at our hospital, we retrospectively analyzed the records of 70 patients (42 men, 28 women; median age, 63 years) in whom the stent tail was positioned inside the bladder without crossing the midline and who completed the core lower urinary tract symptoms score (CLSS) questionnaire pre- and postoperatively. Results There were significant differences in incomplete emptying (p=0.048) and bladder pain (p=0.041) between patients with loop-tail versus pigtail ureteral stents after URSL. In the multivariate analysis, stent type had a stronger association with incomplete emptying (p=0.022) and bladder pain (p=0.018) than age, sex, body mass index, stent side, operation time, diameter of ureteral access sheath, and stent type. Conclusions Patients with loop-tail ureteral stents had better urination-related QoL in the immediate post-URSL stage than patients with pigtail stents. PMID:29124244

  2. Surgical Management of Nephrolithiasis in the Bottlenose Dolphin: Collaborations Between the Urologist and Veterinarian.

    PubMed

    Sur, Roger L; Meegan, Jenny M; Smith, Cynthia R; Schmitt, Todd; L'Esperance, James; Hendrikson, Dean; Woo, Jason R

    2018-01-01

    Background: Cohorts of bottlenose ( Tursiops truncatus ) dolphins are at significant risk for nephrolithiasis development. However, effective surgical treatment has been limited due to absence of literature and also familiarity by both veterinarians and urologists. Recently a joint veterinarian and urology team were called to treat local bottlenose dolphins in San Diego, CA, and they performed several cases. The fund of knowledge from these cases is presented for future providers who may be asked to surgically treat these animals. Case Presentation: Two surgical kidney stone cases were performed by a joint veterinarian and physician team. An effective ureteroscopic stone removal was performed on a 39-year-old female bottlenose dolphin with 9.7 mm distal ureteral calculus. The second case involved laparoscopic ureterolithotomy on a 31-year-old male bottlenose dolphin with a 6-mm right distal ureteral calculus that previously failed retrograde ureteroscopic removal. The stone was not effectively removed laparoscopically as well due to failure to progress associated with operative machinery malfunction. The dolphin was ultimately euthanized. Conclusion: Despite suboptimal outcome in one case, extremely valuable lessons were learned during both cases. We present our surgical experiences, as well as pertinent anatomical differences, in these animals with the hope that this discussion will facilitate future surgical kidney stone treatment of dolphins.

  3. Efficacy of combining flexible and rigid ureteroscopy for transurethral lithotripsy.

    PubMed

    Shigemura, Katsumi; Yasufuku, Tomihiko; Yamashita, Masuo; Arakawa, Soichi; Fujisawa, Masato

    2010-08-23

    Transurethral lithotripsy (TUL) is a common procedure in urology. However, controversy persists about how to deal with stones pushed up into kidney from the ureter during the procedure of TUL. This study investigated the efficacy of combining flexible ureteroscopy and rigid ureteroscopy for pushed-up stones into kidney during TUL. Fotry-one patients underwent TUL by a single surgeon from July 2007 to May 2009. Eight cases resulted in pushed-up stones during operation or involved existing kidney stones. We used a Zero-tip or Litho Catch Basket catheter and a flexible ureteroscope to carry these stones in kidney down into the ureter where the rigid ureteroscope could then reach and handle the stone for lithotripsy or being taken away. A Lithoclast system was used for lithotripsy. Five cases involved stones pushed up during surgery and 3 cases involved stones already in the kidney in detail. We pulled the stones down into the ureter in all cases and successfully completed lithotripsy or removed the stone, thus avoiding the performance of additional extracorporeal shock wave lithotripsy (ESWL). In conclusions, combined use of flexible ureteroscopy and rigid ureteroscopy for upper urinary tract stones pushed up into the kidney during TUL or renal stones could be useful for avoiding additional ESWL.

  4. Surgical Management of Nephrolithiasis in the Bottlenose Dolphin: Collaborations Between the Urologist and Veterinarian

    PubMed Central

    Meegan, Jenny M.; Smith, Cynthia R.; Schmitt, Todd; L'Esperance, James; Hendrikson, Dean; Woo, Jason R.

    2018-01-01

    Abstract Background: Cohorts of bottlenose (Tursiops truncatus) dolphins are at significant risk for nephrolithiasis development. However, effective surgical treatment has been limited due to absence of literature and also familiarity by both veterinarians and urologists. Recently a joint veterinarian and urology team were called to treat local bottlenose dolphins in San Diego, CA, and they performed several cases. The fund of knowledge from these cases is presented for future providers who may be asked to surgically treat these animals. Case Presentation: Two surgical kidney stone cases were performed by a joint veterinarian and physician team. An effective ureteroscopic stone removal was performed on a 39-year-old female bottlenose dolphin with 9.7 mm distal ureteral calculus. The second case involved laparoscopic ureterolithotomy on a 31-year-old male bottlenose dolphin with a 6-mm right distal ureteral calculus that previously failed retrograde ureteroscopic removal. The stone was not effectively removed laparoscopically as well due to failure to progress associated with operative machinery malfunction. The dolphin was ultimately euthanized. Conclusion: Despite suboptimal outcome in one case, extremely valuable lessons were learned during both cases. We present our surgical experiences, as well as pertinent anatomical differences, in these animals with the hope that this discussion will facilitate future surgical kidney stone treatment of dolphins. PMID:29756043

  5. Radiotherapeutic bandage based on electrospun polyacrylonitrile containing holmium-166 iron garnet nanoparticles for the treatment of skin cancer.

    PubMed

    Munaweera, Imalka; Levesque-Bishop, Daniel; Shi, Yi; Di Pasqua, Anthony J; Balkus, Kenneth J

    2014-12-24

    Radiation therapy is used as a primary treatment for inoperable tumors and in patients that cannot or will not undergo surgery. Radioactive holmium-166 ((166)Ho) is a viable candidate for use against skin cancer. Nonradioactive holmium-165 ((165)Ho) iron garnet nanoparticles have been incorporated into a bandage, which, after neutron-activation to (166)Ho, can be applied to a tumor lesion. The (165)Ho iron garnet nanoparticles ((165)HoIG) were synthesized and introduced into polyacrylonitrile (PAN) polymer solutions. The polymer solutions were then electrospun to produce flexible nonwoven bandages, which are stable to neutron-activation. The fiber mats were characterized using scanning electron microscopy, transmission electron microscopy, powder X-ray diffraction, Fourier transform infrared spectroscopy, thermogravimetric analysis and inductively coupled plasma mass spectrometry. The bandages are stable after neutron-activation at a thermal neutron-flux of approximately 3.5 × 10(12) neutrons/cm(2)·s for at least 4 h and 100 °C. Different amounts of radioactivity can be produced by changing the amount of the (165)HoIG nanoparticles inside the bandage and the duration of neutron-activation, which is important for different stages of skin cancer. Furthermore, the radioactive bandage can be easily manipulated to irradiate only the tumor site by cutting the bandage into specific shapes and sizes that cover the tumor prior to neutron-activation. Thus, exposure of healthy cells to high energy β-particles can be avoided. Moreover, there is no leakage of radioactive material after neutron activation, which is critical for safe handling by healthcare professionals treating skin cancer patients.

  6. A primary exploration to quasi-two-dimensional rare-earth ferromagnetic particles: holmium-doped MoS2 sheet as room-temperature magnetic semiconductor

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Lin, Zheng-Zhe

    2018-05-01

    Recently, two-dimensional materials and nanoparticles with robust ferromagnetism are even of great interest to explore basic physics in nanoscale spintronics. More importantly, room-temperature magnetic semiconducting materials with high Curie temperature is essential for developing next-generation spintronic and quantum computing devices. Here, we develop a theoretical model on the basis of density functional theory calculations and the Ruderman-Kittel-Kasuya-Yoshida theory to predict the thermal stability of two-dimensional magnetic materials. Compared with other rare-earth (dysprosium (Dy) and erbium (Er)) and 3 d (copper (Cu)) impurities, holmium-doped (Ho-doped) single-layer 1H-MoS2 is proposed as promising semiconductor with robust magnetism. The calculations at the level of hybrid HSE06 functional predict a Curie temperature much higher than room temperature. Ho-doped MoS2 sheet possesses fully spin-polarized valence and conduction bands, which is a prerequisite for flexible spintronic applications.

  7. Predicting lanthanide cluster properties: a comparison with the observed optical spectra of HO 2

    NASA Astrophysics Data System (ADS)

    Nemukhin, A. V.; Ermilov, A. Yu.; Petrukhina, M. A.; Klotzbücher, W. E.; Smets, J.

    1997-10-01

    Ab initio pseudopotential calculations for HO and HO 2 have been carried out in order to support an assignment of the bands observed in UV-visible spectra of matrix isolated holmium species. SCF, MCSCF and configuration interaction (CI) procedures have been used with quasirelativistic pseudopotentials to compute the ground and excited state energies of HO and HO 2, together with the dipole transition moments. For HO 2, using a Q = 11 pseudopotential (describing the holmium atom in the 4f 106s 25d 1 electronic state), two transitions from the ground state σg2σu2πu2 to the states with principal excitations σu → πg and π u → σ g∗ are predicted at 499 and 524 nm. These two lines, with predicted close intensities, correlate nicely with the observed features at 498/504 and 558/563nm in the spectrum of matrix-isolated HO 2.

  8. Yb3+/Ho3+-codoped antimony-silicate optical fiber

    NASA Astrophysics Data System (ADS)

    Żmojda, Jacek; Dorosz, Dominik; Kochanowicz, Marcin; Miluski, Piotr; Dorosz, Jan

    2012-05-01

    The emission properties of Yb3+/Ho3+-codoped antimony-silicate optical fiber has been investigated. Luminescence at 2.1 μm corresponding to 5I7--> 5I8 transition in holmium was obtained by energy transfer between Yb3+ and Ho3+ ions. According to the Dexter-Miyakawa model, the parameters of energy migration CDD of the 2F5/2 (Yb3+) <--> 2F5/2 (Yb3+) transition and direct energy transfer CDA of the 2F5/2 (Yb3+) --> 5I6 (Ho3+) transition was calculated. The optimization of the activator content and the concentration ratio were conducted with the purpose of maximizing the efficiency of energy transfer. It made possible to select best-suited glass which was used to manufacture double-clad optical fiber. Strong and narrow bands of spontaneous emission which formed as a result of energy transfer between ytterbium and holmium ions were observed in the fiber under exciting with radiation at 978 nm wavelength.

  9. Line Identification of Atomic and Ionic Spectra of Holmium in the Near-UV. Part I. Spectrum of Ho I

    NASA Astrophysics Data System (ADS)

    Al-Labady, N.; Özdalgiç, B.; Er, A.; Güzelçimen, F.; Öztürk, I. K.; Kröger, S.; Kruzins, A.; Tamanis, M.; Ferber, R.; Başar, Gö.

    2017-02-01

    The Fourier Transform spectra of a Holmium hollow cathode discharge lamp have been investigated in the UV spectral range from 25,000 up to 31,530 cm-1 (317 to 400 nm). Two Ho spectra have been measured with neon and argon as buffer gases. Based on the intensity ratios from these two spectra, a distinction was made between atomic and ionic lines (ionic lines are discussed in an accompanying paper). Using the known Ho I energy levels, 71 lines could be classified as transitions of atomic Ho, 34 of which have not been published previously. Another 32 lines, which could not be classified, are listed in the literature and assigned as atomic Ho. An additional 370 spectral lines have been assigned to atomic Ho based on the signal-to-noise ratio in the two spectra measured under different discharge conditions, namely with buffer gases argon and neon, respectively. These 370 lines have not been previously listed in the literature.

  10. Clinical Significance of Prostatic Calculi: A Review

    PubMed Central

    2018-01-01

    Prostatic calculi often occur in middle-aged and old men. Prostatic calculi are usually classified as primary/endogenous stones or secondary/extrinsic stones. Endogenous stones are commonly caused by obstruction of the prostatic ducts around the enlarged prostate by benign prostatic hyperplasia (BPH) or by chronic inflammation. Extrinsic stones occur mainly around the urethra, because they are caused by urine reflux. The exact prevalence of prostatic calculi is not known, and it has been reported to vary widely, from 7% to 70%. Most cases of prostatic calculi are not accompanied by symptoms. Therefore, most cases are found incidentally during the diagnosis of BPH using transrectal ultrasonography (TRUS). However, prostatic calculi associated with chronic prostatitis may be accompanied by chronic pelvic pain. Rare cases have been reported in which extrinsic prostatic calculi caused by urine reflux have led to voiding difficulty due to their size. More than 80% of prostatic calculi are composed of calcium phosphate. Prostatic calculi can be easily diagnosed using TRUS or computed tomography. Treatment is often unnecessary, but if an individual experiences difficulty in urination or chronic pain, prostatic calculi can be easily removed using a transurethral electroresection loop or holmium laser. PMID:29076299

  11. Structural and luminescence studies of Ho{sup 3+}-doped zinc-aluminium-sodium-phosphate (ZANP) glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brahmachary, K.; Rajesh, D.; Ratnakaram, Y. C., E-mail: ratnakaramsvu@gmail.com

    Trivalent holmium doped zinc-aluminium-sodium-phosphate (ZANP) glasses were prepared by conventional melt-quenching technique and characterized for their structural and luminescence properties. The amorphous nature, elemental analysis and thermal stability of the glasses were studied by using X-ray diffraction, energy dispersive spectrum and differential scanning calorimetry analysis, respectively. The absorption and fluorescence spectra have been recorded at room temperature. Based on the absorption spectra, the Judd-Ofelt parameters and radiative parameters such as spontaneous transition probabilities (A{sub R}), branching ratios (β{sub R}), radiative lifetimes (τ{sub R}) were calculated and discussed. From the emission spectra emission peak positions (λ{sub P}), effective bandwidths (Δλ{sub eff})more » and stimulated emission cross-sections (σ{sub P}) were calculated for the observed emission transitions,{sup 5}S{sub 2} ({sup 5}F{sub 4}→{sup 5}I{sub 8}) and {sup 5}F{sub 5}→{sup 5}I{sub 8} in all the glass samples. The stimulated emission cross-section is higher for ZANPHo10 glass matrix and so it may be useful for laser excitation.« less

  12. ''Sandwich'' treatment for diospyrobezoar intestinal obstruction: A case report

    PubMed Central

    Zheng, Yi-Xiong; Prasoon, Pankaj; Chen, Yan; Hu, Liang; Chen, Li

    2014-01-01

    Intestinal obstruction is a common clinical entity encountered in surgical practice. The objective of this report is to corroborate an atypical scenario of intestinal obstruction in a Chinese patient and to focus on the diagnosis and treatment. A 27-year-old male presented with a history of gastric pain combined with nausea and abdominal distension that had been present for 5 d. The presence of a foreign body was detected by computed tomography and observed as an abnormal density within the stomach. A diospyrobezoar was revealed during gastroscopy, the extraction of which was prevented due to its size and firmness. An endoscopic holmium laser joined with a snare was used to fragment the obstruction, which was followed by management with a conservative “sandwich” treatment strategy involving intestinal decompression with an ileus tube and Coca-Cola lavage between endoscopic lithotripsy fragmentation procedures. This strategy resulted in the successful removal of the diospyrobezoar along with multiple small bowel obstructions. The patient was discharged after abatement of symptoms. The case presented here demonstrates the implementation of a conservative, yet successful, treatment as an alternative to conventional surgical removal of intestinal obstructions. PMID:25561823

  13. An Efficient Single Frequency Ho:YLF Laser for IPDA Lidar Applications

    NASA Technical Reports Server (NTRS)

    Yu, J.; Bai, Y.; Wong, T.; Reithmeier, K.; Petros, M.

    2016-01-01

    A highly efficient, versatile, single frequency 2-micron pulsed laser can be used in a pulsed Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) instrument to make precise, high-resolution measurements to investigate sources and sinks of CO2. For a direct detection IPDA lidar, the desired 2 ?m Ho:YLF laser should generate 30-40 mJ pulses at the repetition rate of 100 to 200 Hz, with short pulse length (<100 ns) and better than 2% wall plug efficiency. A Tm fiber laser in-band pumped Ho:YLF laser has been developed to meet this technical challenge. This Ho:YLF laser is designed in a four mirror ring resonator with bow tie configuration, which helps to obtain high beam quality. It is end-pumped by a 40 W linearly polarized Tm fiber laser at 1.94µm. The resonator length is 1.10 meters with output coupler reflectivity at 45%. The laser crystal size is 3 x 3 x 60 mm (w, h, l) with a doping concentration of 0.5% Holmium. The laser beam and pump beam are mode-matched in the active medium. Thus, the pump and laser beams have the same confocal parameters. Mode-matching is also helpful for operating the laser in a single transverse mode. The laser beam waist is slightly less than 0.5 mm at the center of the laser crystal. Based on quasi-four level modeling, pump absorption and saturation depend on laser intensity. Laser amplification and saturation also depend on the pump intensity in the crystal. The laser is injection seeded to obtain the single frequency required by an IPDA lidar measurement. The seed beam is entered into the resonator through an output coupler. The laser is mounted on a water cooled optical bench for stable and reliable operation. The size of the optical bench is 22.16 x 9.20 x 1.25 inches. It is stiffened so that the laser can be operated in any orientation of the optical bench. This packaged Ho:YLF laser is designed for either mobile trailer or airborne platform operation. The engineering prototype Ho:YLF laser has been fully characterized to demonstrate laser performance. Figure 1 shows the laser output power as a function of pump power at different pulse repetition rates from 100 Hz to 333 Hz. The threshold of the laser is less than 14 W. The slope efficiencies are 28%, 40%, 41% and 43% for pulse repetition rates of 100, 200, 250 and 333 Hz, respectively. Maximum power increases with the pulse repetition rate. Output power of 4.2 W, 6 W, 6.7 W, and 7.7 W is achieved for pulse repetition rates of 100, 200, 250 and 333Hz, respectively. This represents the optical conversion efficiency of 16.7%, 22.4%, 23.7%, and 26.5% at these various pulse repletion rates. It is the most efficient and compact Ho:YLF laser demonstrated in the high pulse energy (>20mJ) and moderate pulse repetition rate (100's Hz) operation range. As shown in Figure 1, the maximum pulse energy at 100 Hz is 42 mJ. This is limited due to optical damage. The laser stability is characterized and found to be very stable. A relative pulse energy standard deviation of 2% was measured. The beam quality of the Ho:YLF was measured by a Spiricon infrared laser beam camera. Figure 2 shows the beam profile image of the laser. Both the X-profile of the beam (horizontal direction) and the Y-profile of the beam (vertical direction) are well fitted by a Gaussian profile. The qualitative beam quality measurement shows excellent beam quality in both axis. The M-square value for the laser beam is measured at 1.06 and 1.09 for the x and y axis respectively.-

  14. Urological applications of Ho/Nd:Yag laser

    NASA Astrophysics Data System (ADS)

    Grifoni, Riccardo; Pierangeli, Tiziana; Gioacchini, Andrea; Muraro, Giovanni B.

    2001-10-01

    The introduction of Ho:Yag laser has brought many advantages in urology. By this work we want show you our experience with this technology. Between April 1998 and May 2000 we treated 137 patients. Of these 28 had urinary lithiasis (18 bladder and 10 ureteral stones 3 in the upper, 2 in the middle and 5 in the distal tract), 40 were affected by enlargement of prostatic gland: 32 had B.P.H., 8 P.C.; 36 had T.C.C. and 33 strictures of urethra (27) or bladder neck (6). For ureteral lithiasis we used 200 micrometer fiber, energy of 0.5 - 1.4 J with 10 Hz of frequency. In case of bladder stones a 550 or 1000 micrometer using a power of 80 W. The prostatic gland were resected by a 550 micrometer fiber, 2.2 - 2.8 J, 25 - 30 Hz and 70 -80 W. The superficial bladder tumors were removed by 1.4 J with 10 - 15 Hz and 10 - 14 W. In the large tumors we completed the procedure by Nd:YAG at the base of the tumor. Urethra and bladder neck strictures were treated by 1.2 - 1.8 J and 10 - 30 Hz. We successful treated 26 patients with urinary lithiasis obtained the complete vaporization of the stones, 2 had endoscopic ancillary procedures. Out of 32 patients with B.P.H. 41% had the complete resection of the gland the others the resection of the 3d lobe. We removed 114 superficial bladder tumors and only 4 patients had a local recurrence. Of the patients with the strictures 4 had more than one treatment and about 87% had good result. From our experience the use of Holmium:Yag laser has been very efficacy to treat different urological diseases, also in patients with important comorbid disorders and its use reduce the stay in hospital and so the costs.

  15. [Safety and effect of transurethral holmium laser enucleation of the prostate versus bipolar transurethral plasmakinetic prostatectomy for benign prostatic hyperplasia: A meta-analysis].

    PubMed

    Guo, Qiang; Xiao, Yi; Li, Jian-Wen; Zhang, Jian-Dong; Zhang, Yan-Gang

    2016-10-01

    To evaluate the safety and effect of transurethral holmium laser enucleation of the prostate (HoLEP) in comparison with bipolar transurethral plasmakinetic prostatectomy (TUPKP) in the treatment of benign prostatic hyperplasia (BPH). We searched the databases of PubMed, SCI, Ovid, The Cochrane Library, CNKI, CBM, VIP, and Wangfang Data for controlled clinical trials about HoLEP versus TUPKP in the treatment of BPH published up to April 2016. The studies were screened according to the inclusion and exclusion criteria, the data extracted, and their quality evaluated by 2 reviewers independently, followed by a meta-analysis using the RevMan 5.3 software. A total of 7 studies were included, involving 2031 cases. In comparison with TUPKP, HoLEP showed significantly longer operation time (WMD = 24.61, 95% CI 11.88, 37.34, P lt; 0.001), shorter hospital stay (WMD =-1.91, 95% CI -3.74, -0.07, P = 0.04), shorter bladder irrigation time (WMD = -21.50, 95% CI -34.95, -8.06, P = 0.002), shorter catheter-indwelling time (WMD = -27.60, 95% CI -48.17, -7.03, P = 0.009), less hemoglobin loss (WMD = - 0.42, 95% CI -0.78, -0.07, P = 0.02); lower postvoid residual urine (PVR) at 3 months (WMD = -3.35, 95% CI -4.46, -2.23, P<0.001) and 6 months after surgery (WMD =-1.11, 95% CI -2.18, -0.05, P = 0.04); higher maximum urinary flow rate (Qmax) (WMD = 0.42, 95% CI 0.04, 0.80, P = 0.03) and fewer urinary tract irritation symptoms (OR =0.58, 95% CI 0.41, 0.81, P = 0.002) at 12 months after surgery. No statistically significant differences were found between the two groups in the volume of resected tissue, serum sodium reduction, urethral stricture, erectile dysfunction, retrograde ejaculation, or transient urinary incontinence (P>0.05), or in the improvement of the quality of life (QoL) at 1, 3 and 12 months, International Prostate Symptom Score (IPSS) at 1, 3, 6 and 12 months, Qmax at 1, 3 and 6 months, or International Index of Erectile Function-5 (IIEF-5) at 6 months after surgery (P>0.05). HoLEP is preferred to TUPKP in clinical application for its advantages of higher Qmax at 12 months after surgery, lower PVR at 3 and 6 months, higher peri-operative safety, faster recovery, and fewer urinary tract irritation symptoms. However, for the quantity and quality limitations of the included publications, our findings are to be further supported by large-sample, multi-center, and high-quality prospective controlled clinical studies.

  16. Transurethral ultrasonic ureterolithotripsy using a solid-wire probe.

    PubMed

    Chaussy, C; Fuchs, G; Kahn, R; Hunter, P; Goodfriend, R

    1987-05-01

    A multicenter study evaluates a new technique for transurethral ultrasonic ureterolithotripsy utilizing a solid-wire probe. The transverse vibrations of the probe cause greater stone disintegration. A small ureteroscope is used and a basket is not required. There was a 96.6 per cent success rate in 118 cases. This technique has significantly improved ultrasonic lithotripsy. It has proved to be useful for upper ureteral stones not amenable to extracorporeal shock-wave lithotripsy and lower ureteral stones including "steinstrasse."

  17. Refining the intraoperative measurement of the distal intrapancreatic part of a choledochal cyst during laparoscopic repair allows near total excision.

    PubMed

    Koga, Hiroyuki; Okawada, Manabu; Doi, Takashi; Miyano, Go; Lane, Geoffrey J; Yamataka, Atsuyuki

    2015-10-01

    During surgery for choledochal cyst (CC), any intrapancreatic CC (IPCC) must also be excised to prevent postoperative pancreatitis and stone formation. We report our technique for laparoscopic total IPCC excision (n = 16; mean age 6.0 years). We insert a fine ureteroscope with a light source into the opened CC through an extra 3.9-mm trocar placed in the epigastrium through a minute incision to identify the pancreatic duct orifice. By pulling the end of the ureteroscope emerging from the trocar gently to withdraw the tip from the pancreatic duct to where distal dissection was ceased under laparoscopic view, the IPCC can be measured. If longer than 5 mm, the distal CC is dissected further caudally until it is less than 5 mm. For accuracy, the distal CC is elevated with a suture that is exteriorized and clamped to provide constant traction. The IPCC was able to be measured in 11/16 (68 %). Initial lengths measured were 3-10 mm (5.2 ± 2.7 mm). Final IPCC were all 5 mm or less. Surgery was uncomplicated without any pancreatic duct injury and postoperative recovery was unremarkable. Follow-up MRI at 32 months showed no IPCC in any case. Measuring the IPCC enables total CC excision, thus reducing the potential for postoperative complications.

  18. Robotically assisted ureteroscopy for kidney exploration

    NASA Astrophysics Data System (ADS)

    Talari, Hadi F.; Monfaredi, Reza; Wilson, Emmanuel; Blum, Emily; Bayne, Christopher; Peters, Craig; Zhang, Anlin; Cleary, Kevin

    2017-03-01

    Ureteroscopy is a minimally invasive procedure for diagnosis and treatment of urinary tract pathology. Ergonomic and visualization challenges as well as radiation exposure are limitations to conventional ureteroscopy. Therefore, we have developed a robotic system to "power drive" a flexible ureteroscope with 3D tip tracking and pre-operative image overlay. The proposed system was evaluated using a kidney phantom registered to pre-operative MR images. Initial experiments show the potential of the device to provide additional assistance, precision, and guidance during urology procedures.

  19. Experimental application of pulsed laser-induced water jet for endoscopic submucosal dissection: mechanical investigation and preliminary experiment in swine.

    PubMed

    Sato, Chiaki; Nakano, Toru; Nakagawa, Atsuhiro; Yamada, Masato; Yamamoto, Hiroaki; Kamei, Takashi; Miyata, Go; Sato, Akira; Fujishima, Fumiyoshi; Nakai, Masaaki; Niinomi, Mitsuo; Takayama, Kazuyoshi; Tominaga, Teiji; Satomi, Susumu

    2013-05-01

    A current drawback of endoscopic submucosal dissection (ESD) for early-stage gastrointestinal tumors is the lack of instruments that can safely assist with this procedure. We have developed a pulsed jet device that can be incorporated into a gastrointestinal endoscope. Here, we investigated the mechanical profile of the pulsed jet device and demonstrated the usefulness of this instrument in esophageal ESD in swine. The device comprises a 5-Fr catheter, a 14-mm long stainless steel tube for generating the pulsed water jet, a nozzle and an optical quartz fiber. The pulsed water jet was generated at pulse rates of 3 Hz by irradiating the physiological saline (4°C) within the stainless steel tube with an holmium-doped yttrium-aluminum-garnet (Ho:YAG) laser at 1.1 J/pulse. Mechanical characteristics were evaluated using a force meter. The device was used only for the part of submucosal dissection in the swine ESD model. Tissues removed using the pulsed jet device and a conventional electrocautery device, and the esophagus, were histologically examined to assess thermal damage. The peak impact force was observed at a stand-off distance of 40 mm (1.1 J/pulse). ESD using the pulsed jet device was successful, as the tissue specimens showed precise dissection of the submucosal layer. The extent of thermal injury was significantly lower in the dissected bed using the pulsed jet device. The results showed that the present endoscopic pulsed jet system is a useful alternative for a safe ESD with minimum tissue injury. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  20. Addition of Sodium Bicarbonate to Irrigation Solution May Assist in Dissolution of Uric Acid Fragments During Ureteroscopy.

    PubMed

    Paonessa, Jessica E; Williams, James C; Lingeman, James E

    2018-04-01

    We hypothesized that adding sodium bicarbonate (bicarb) to normal saline (NS) irrigation during ureteroscopy in patients with uric acid (UA) nephrolithiasis may assist in dissolving small stone fragments produced during laser lithotripsy. In vitro testing was performed to determine whether dissolution of UA fragments could be accomplished within 1 hour. In total 100% UA renal calculi were fragmented, filtered, and separated by size. Fragment sizes were <0.5 mm and 0.5 to 1 mm. Similar amounts of stone material were agitated in solution at room temperature. Four solutions were tested (NS, NS +1 ampule bicarb/L, NS +2, NS +3). Both groups were filtered to remove solutions after fixed periods. Filtered specimens were dried and weighed. Fragment dissolution rates were calculated as percent removed per hour. Additional testing was performed to determine whether increasing the temperature of solution affected dissolution rates. For fragments <0.5 mm, adding 2 or 3 bicarb ampules/L NS produced a dissolution rate averaging 91% ± 29% per hour. This rate averaged 226% faster than NS alone. With fragments 0.5 to 1 mm, addition of 2 or 3 bicarb ampules/L NS yielded a dissolution rate averaging 22% ± 7% per hour, which was nearly five times higher than NS alone. There was a trend for an increase in mean dissolution rate with higher temperature but this increase was not significant (p = 0.30). The addition of bicarbonate to NS more than doubles the dissolution rate of UA stone fragments and fragments less than 0.5 mm can be completely dissolved within 1 hour. Addition of bicarb to NS irrigation is a simple and inexpensive approach that may assist in the dissolution of UA fragments produced during ureteroscopic laser lithotripsy. Further studies are needed to determine whether a clinical benefit exists.

  1. Effectiveness of Prophylactic Antibiotics against Post-Ureteroscopic Lithotripsy Infections: Systematic Review and Meta-Analysis.

    PubMed

    Lo, Chi-Wen; Yang, Stephen Shei-Dei; Hsieh, Cheng-Hsing; Chang, Shang-Jen

    2015-08-01

    To evaluate the effectiveness of prophylactic antibiotic therapy in reducing the incidence of post-ureteroscopic lithotripsy (URL) infections. A systemic search of PubMED was performed to identify all randomized trials that compared the incidence of post-operative infections in patients without pre-operative urinary tract infections who underwent URL with and without a single dose of prophylactic antibiotics. The data were analyzed using Cochrane Collaboration Review Manager (RevMan, version 5.2). The endpoints of the analysis were pyuria (>10 white blood cells/high-power field), bacteriuria (urine culture with bacteria >10(5) colony-forming units/mL), and febrile urinary tract infections (fUTIs), defined as a body temperature of >38°C with pyuria or meaningful bacteriuria within 1 wk after the operation. In total, four trials enrolling 500 patients met the inclusion criteria and were subjected to meta-analysis. Prophylactic antibiotics significantly reduced post-URL pyuria (risk ratios [RR] 0.65; 95% confidence interval [CI] 0.51-0.82) and bacteriuria (RR 0.26; 95% CI 0.12-0.60; p=0.001). Patients who received prophylactic antibiotics tended to have lower rates of fUTI, although the difference was not statistically significant. Prophylactic antibiotic therapy can reduce the incidence of pyuria and bacteriuria after URL. However, because of the low incidence of post-URL fUTIs, we failed to show that a single dose of prophylactic antibiotics can reduce the rate of such infections significantly.

  2. Immediate and late management of iatrogenic ureteric injuries: 28 years of experience.

    PubMed

    El Abd, Ahmed S; El-Abd, Shawky A; El-Enen, Mohamed Abo; Tawfik, Ahmed M; Soliman, Mohamed G; Abo-Farha, Mohamed; Gamasy, Abd-El Naser El; El-Sharaby, Mahmoud; El-Gamal, Samir

    2015-12-01

    To evaluate the long-term results after managing intraoperative and late-diagnosed cases of iatrogenic ureteric injury (IUI), treated endoscopically or by open surgery. Patients immediately diagnosed with IUI were managed under the same anaesthetic, while those referred late had a radiological assessment of the site of injury, and endoscopic management. Open surgical procedures were used only for the failed cases with previous diversion. In all, 98 patients who were followed had IUI after gynaecological, abdominopelvic and ureteroscopic procedures in 60.2%, 14.3% and 25.5%, respectively. The 27 patients diagnosed during surgery were managed immediately, while in the late-referred 71 patients ureteroscopic ureteric realignment with stenting was successful in 26 (36.6%). Complex open reconstruction with re-implantation or ureteric substitution, using bladder-tube or intestinal-loop procedures, was used in 27 (60%), 16 (35.5%) and two (4.5%) patients of the late group, respectively. A long-term radiological follow-up with a mean (range) of 46.6 (24.5-144) months showed recurrent obstruction in 16 (16.3%) patients managed endoscopically and reflux in six (8.3%) patients. Three renal units only (3%) were lost in the late-presenting patients. Patients managed immediately had better long-term results. More than a third of the late-diagnosed patients were successfully managed endoscopically with minimal morbidity. Open reconstruction by an experienced urologist who can perform a complex substitutional procedure was mandatory to preserve renal units in the long-term.

  3. Mechanical Implantation of Urothelium Into Periureteral Soft Tissue: A Series of 4 Cases Mimicking High-stage Urothelial Carcinoma.

    PubMed

    Wobker, Sara E; Aron, Manju; Epstein, Jonathan I

    2016-11-01

    In the upper genitourinary tract of the ureter and renal pelvis, any invasion of urothelial carcinoma (UC) beyond the thin muscularis is considered pT3 disease, which may prompt adjuvant chemotherapy. Ureteroscopy is commonly used in the workup of these lesions to obtain tissue biopsies and cytology specimens, or to place stents for the relief of obstructive symptoms. The current study describes 4 cases in which the presence of small nests of urothelium in periureteral and peripelvic soft tissue was noted after ureteroscopic instrumentation, mimicking high-stage UC. All 4 cases had a history of ureteral instrumentation with biopsy of the suspected UC. The diagnostic biopsies showed low-grade noninvasive papillary UC (n=2), papillary urothelial neoplasm of uncertain malignant potential (n=1), and benign inverted urothelial papilloma (n=1). In the definitive resection specimens, small nests of bland urothelium were present in the periureteral or peripelvic soft tissue, raising the possibility of pT3 UC. We interpreted these displaced small nests to be the result of mechanical implantation occurring during the ureteroscopic procedure on the basis of the finding of associated linear fibrosis, inflammation, hemorrhage, and foreign body giant cells. In the setting of low-grade or benign urothelial neoplasms in the upper urinary tract, caution is warranted when cytologically bland nests of the urothelium are identified beyond the muscularis that could represent mechanically induced implants as opposed to invasive UC extending into peripelvic or periureteral soft tissue.

  4. Systematic review of ureteral access sheaths: facts and myths.

    PubMed

    De Coninck, Vincent; Keller, Etienne Xavier; Rodríguez-Monsalve, María; Audouin, Marie; Doizi, Steeve; Traxer, Olivier

    2018-05-11

    The aim of the present paper was to review the literature on all available ureteral access sheaths (UASs) with their indications, limitations, risks, advantages and disadvantages in current modern endourological practice. Two authors searched Medline, Scopus, Embase and Web of Science databases to identify studies on UASs published in English. No time period restriction was applied. All original articles reporting outcomes or innovations were included. Additional articles identified through references lists were also included. Case reports, editorials, letters, review articles and meeting abstracts were excluded. A total of 754 abstracts were screened, 176 original articles were assessed for eligibility and 83 articles were included in the review. Based on a low level of evidence, UASs increase irrigation flow during flexible ureteroscopy and decrease intrapelvic pressure and probably infectious complications. Data were controversial and sparse on the impact of UASs on multiple reinsertions and withdrawals of a ureteroscope, stone-free rates, ureteroscope protection or damage, postoperative pain, risk of ureteral strictures, and also on its cost-effectiveness. Studies on the benefit of UASs in paediatrics and in patients with a coagulopathy were inconclusive. In the absence of good randomized data, the true impact of UASs on surgery outcome remains unclear. The present review may contribute to the evidence-based decision-making process at the individual patient level regarding whether or not a UAS should be used. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  5. Anesthetic exposure in the treatment of symptomatic urinary calculi in pregnant women.

    PubMed

    Rivera, Marcelino E; McAlvany, Kelly L; Brinton, Thomas S; Gettman, Matthew T; Krambeck, Amy E

    2014-12-01

    To assess the duration and total number of anesthetic exposures required for the treatment of urolithiasis during pregnancy, specifically comparing temporizing measures with active treatment because urolithiasis and its management may pose potential theoretical risks for the mother and fetus. We retrospectively reviewed patients with a confirmed diagnosis of urolithiasis during pregnancy who underwent surgical intervention from 1997 to 2012 at our institution. The number and duration of anesthetic exposures were assessed. We identified 26 women with urolithiasis during pregnancy, of which 15 (58%) were treated with temporizing stents and 11 (42%) with ureteroscopic stone extraction. In the ureteroscopy group, the median number of anesthetic exposures was 1.18 (interquartile range [IQR], 1-2), and the median total anesthetic time was 80 minutes (IQR, 37-126 minutes). In the stent group, 6 (40%) required multiple stent exchanges for a median of 1.47 (IQR, 1-3) anesthetic events and a median total anesthetic time of 70 minutes (IQR, 29-208 minutes). In the ureteral stent group, 7 women (47%) were induced before spontaneous labor due to inability to tolerate the stent. There was no difference in the number of anesthetic events (P = .208) or anesthesia time (P = .503) between stenting and ureteroscopy. Women undergoing ureteroscopic surgical intervention during pregnancy were at no greater risk in the number or cumulative duration of anesthesia exposure than women managed with temporizing ureteral stent placement and subsequent exchanges. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. [Clinical, ureteroscopic and photodynamic diagnosis of urothelial carcinomas of the upper tract: state-of-the art review for the yearly scientific report of the French National Association of Urology].

    PubMed

    Nison, L; Bozzini, G; Rouprêt, M; Traxer, O; Colin, P

    2014-11-01

    To propose a state-of-the art of current knowledge about clinical, ureteroscopic and photodynamic for the diagnosis of the upper urinary tract cancer (UTUC). A systematic review of the literature search was performed from the database Medline (NLM, Pubmed), focused on the following keywords: urothelial carcinomas; upper urinary tract; ureter; renal pelvis; diagnosis; fluorescence; ureteroscopy; photodynamic technique; biopsy; cytology. Gross hematuria and flank pain are the two main clinical symptoms revealing a UTUC in daily clinical practice. Urinary cystoscopy and cystoscopy are mandatory to rule out a concomittant synchronous bladder tumour. Flexible ureteroscopy has revolutionized the management of UTUC by allowing a full exploration of upper urinary tract, an endoscopi vizualization of the tumour and assessment of grade with biopsies. A flexible ureteroscopy is mandatory in diagnostic evaluation of UTUC as soon as a conservative management is being considered. New investigation technologies such as fluorescence, narrow band imaging and optical coherence tomography (± combined with ultra sound), are promising for a near future. It has to be understood that the diagnostic work-up of a UTUC has to be exhaustive and particularly the search of another urothelial carcinoma within the urinary tract. Flexible ureterosocopy has revolutionized the diagnosis and management of UTUC and belongs fully to its initial evaluation. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  7. Rare Earths; The Fraternal Fifteen (Rev.)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gschneidner, Jr., Karl A.

    1966-01-01

    Rare earths are a set of 15 elements: lanthanum, cerium, praseodymium, neodymium, promethium, samarium, europium, gadolinium, terbium, dysprosium, holmium, erbium, thulium, ytterbium and lutetium. They are not rare and not earths; they are metals and quite abundant. They are studied to develop commercial products which are beneficial to mankind, and because some rare earths are important to fission products.

  8. [Bladder neck sclerosis following prostate surgery : Which therapy when?

    PubMed

    Rassweiler, J J; Weiss, H; Heinze, A; Elmussareh, M; Fiedler, M; Goezen, A S

    2017-09-01

    Secondary bladder neck sclerosis represents one of the more frequent complications following endoscopic, open, and other forms of minimally invasive prostate surgery. Therapeutic decisions depend on the type of previous intervention (e.g., radical prostatectomy, TURP, HoLEP, radiotherapy, HIFU) and on associated complications (e.g., incontinence, fistula). Primary treatment in most cases represents an endoscopic bilateral incision. No specific advantages of any type of the applied energy (i.e., mono-/bipolar HF current, cold incision, holmium/thulium YAG laser) could be documented. Adjuvant measures such as injection of corticosteroids or mitomycin C have not been helpful in clinical routine. In case of first recurrence, a transurethral monopolar or bipolar resection can usually be performed. Recently, the ablation of the scared tissue using bipolar vaporization has been recommended providing slightly better long-term results. Thereafter, surgical reconstruction is strongly recommended using an open, laparoscopic, or robot-assisted approach. Depending on the extent of the bladder neck sclerosis and the underlying prostate surgery, a Y-V/T-plasty, urethral reanastomosis, or even a radical prostatectomy with new urethravesical anastomosis should be performed. Stent implantation should be reserved for patients who are not suitable for surgery. The final palliative measure is a cystectomy with urinary diversion or a (continent) cystostomy.

  9. Rigid ureteroscopy in children: Our experience.

    PubMed

    Sripathi, Venkat; Chowdhary, Sujit K; Kandpal, Deepak K; Sarode, Varun V

    2014-07-01

    To report our experience of Pediatric ureterorenoscopy for ureteric calculi from two tertiary Pediatric urology centers at Apollo Children's Hospital, Chennai and Indraprastha Apollo Hospital, New Delhi. All children who presented with symptomatic ureteric stones greater than 6 mm were entered into the study. All children less than 12 months and more than 18 years of age and those who underwent ureterorenoscopy for indications other than the stones were excluded from the study. The children were managed on a fixed investigative and treatment protocol. The data from the Apollo Hospital New Delhi and Apollo Children's Hospital Chennai was analysed. There were a total of thirty eight children, twenty in Chennai and eighteen in the New Delhi study. The mean age was 10.4 years and 8.5 years and the youngest child was14 months and 24 months in the Chennai and New Delhi group respectively. There was one conversion to open surgery in either group. Pneumatic lithotripter was used in majority of cases and holmium laser in select children. This is the largest Indian series of ureterorenoscopy for ureteric calculi in children. This study over nearly a decade confirms the safety and efficacy of this technique even in young children. In children less than five years, prestenting and delayed ureterorenoscopy allows safe endoscopic treatment of ureteric calculi.

  10. Expanding endourology for biliary stone disease: the efficacy of intracorporeal lithotripsy on refractory biliary calculi.

    PubMed

    Sninsky, Brian C; Sehgal, Priyanka D; Hinshaw, J Louis; McDermott, John C; Nakada, Stephen Y

    2014-07-01

    We evaluated the efficacy of ureteroscopic therapy (electrohydraulic lithotripsy [EHL] and intraductal laser lithotripsy [ILL]) in patients with challenging biliary stones secondary to anatomic variations resulting from a previous surgical procedure, including liver transplantation. A retrospective chart review was performed for all patients with previous surgical alteration of the gastrointestinal (GI) tract who underwent EHL or ILL via peroral or percutaneous access for choledocholithiasis by a single surgeon at our institution from 2000 to 2012. A database containing clinical and surgical variables was created, and long-term follow-up was conducted (3-138 months; median, 99 months). Thirteen patients (51.7±20.0 years; M:F, 10:3) in whom endoscopic retrograde cholangiopancreatography (ERCP), percutaneous transhepatic cholangiography (PTHC), or both failed were identified. Failure of ERCP/PTHC was because of inaccessibility of the calculi in all cases. Stone clearance was achieved in 12/13 (93%) patients; 8/12 (62%) after one procedure, and 4/12 (31%) after two procedures. One patient with biliary cast syndrome needed four interventions over 9 years. Major complications were low, with only one patient with hypotension and cholangitis that resolved with 24 hours of administration of intravenous fluids and antibiotics. Both endoscopic and percutaneous lithotripsies are effective treatments for refractory biliary calculi resulting from the post-surgical GI tract. Although a staged second procedure may be necessary in patients with significant stone burden, this is significantly better than extensive open surgery.

  11. Development of Endoscopic Diagnosis and Treatment for Chronic Unilateral Hematuria: 35 Years Experience.

    PubMed

    Tanimoto, Ryuta; Kumon, Hiromi; Bagley, Demetrius H

    2017-04-01

    Chronic unilateral hematuria (CUH) is also called lateralizing essential hematuria, benign essential hematuria, and benign lateralizing hematuria, which was defined as intermittent or continuous gross hematuria that cannot be diagnosed with standard radiology and hematology studies, together with unilateral bloody efflux by cystoscopy. CUH is rare, but sometimes confused with malignancy or life-threatening hemorrhage. Therefore, it can cause considerable anxiety to not only patients but also urologists. For this study, we summarized articles about endoscopic diagnosis and treatment of CUH, and discussed the development of endourology for CUH. We searched articles related to CUH that were indexed in the PubMed database and published in English. Key terms used were "unilateral," "lateralizing," "chronic," "benign," and "idiopathic" hematuria. We found 15 pertinent articles reporting CUH. Endoscopically, CUH can be classified into three categories: discrete lesion, diffuse lesion, or no (unidentified) lesion. Currently, endoscopic techniques for CUH are similar to the techniques for upper tract urothelial carcinoma, using semi-rigid and flexible ureteroscopes with diathermy fulguration or laser ablation for treatment. The overall success rate of endoscopic treatment for CUH, defined as resolution of gross hematuria after treatment, was 93% (190/205). The recurrence rate, defined as recurrent gross hematuria after treatment, was 10% (19/189). Advancements in endoscopic devices and techniques have enabled more accurate and less invasive diagnosis and treatment of CUH. Once CUH is defined, flexible ureteroscopy is the diagnostic and therapeutic technique of choice.

  12. Tips and tricks of ureteroscopy: consensus statement Part I. Basic ureteroscopy.

    PubMed

    Rukin, Nicholas J; Somani, Bhaskar K; Patterson, Jake; Grey, Ben R; Finch, William; McClinton, Sam; Parys, Bo; Young, Graham; Syed, Haider; Myatt, Andy; Samsudin, Azi; Inglis, John A; Smith, Daron

    2015-01-01

    Ureteroscopy is fast becoming the first line treatment option for the majority of urinary tract stones. Ureteroscopy training can be performed in a variety of ways including simulation, hands on ureteroscopy courses and supervised operative experience. We report an "expert consensus view" from experienced endourological surgeons, on all aspects of basic ureteroscopic techniques, with a particular focus on avoiding and getting out of trouble while performing ureteroscopy. In this paper we provide a summary of treatment planning, positioning, cannulation of ureteric orifice, guidewire placement, rigid ureteroscopy and stone fragmentation.

  13. Tips and tricks of ureteroscopy: consensus statement. Part II. Advanced ureteroscopy.

    PubMed

    Rukin, Nicholas J; Somani, Bhaskar K; Patterson, Jake; Grey, Ben R; Finch, William; McClinton, Sam; Parys, Bo; Young, Graham; Syed, Haider; Myatt, Andy; Samsudin, Azi; Inglis, John A; Smith, Daron

    2016-01-01

    Our "tips and tricks" focuses on all aspects of upper tract endourology and we hope these will be of use to all trainees and consultants who perform ureteroscopy. We report an "expert consensus view" from experienced endourological surgeons, on all aspects of advanced ureteroscopic techniques, with a particular focus on avoiding and getting out of trouble while performing ureteroscopy. In this paper we provide a summary of placing ureteric access sheath, flexible ureteroscopy, intra renal stone fragmentation and retrieval, maintaining visual clarity and biopsy of ureteric and pelvicalyceal tumours.

  14. Management of calculus anuria using ureteroscopic lithotripsy as a first line treatment: its efficacy and safety.

    PubMed

    Savić, Slaviša; Vukotić, Vinka; Lazić, Miodrag; Savić, Nataša

    2014-05-06

    To present our experience with emergency ureteroscopic lithotripsy (URSL) for ureteral calculi associated with acute kidney injury (AKI). We retrospectively evaluated the 61 patients consisted of 90 ureteral units (UU), who underwent URSL. The cause of anuria was bilateral calculus obstructions in 29 cases, and unilateral calculus obstruction with, absent, nephrectomized contralateral kidney in 32 cases. In the case of bilateral synchronous ureteric calculi same-session bilateral ureteroscopy (SBBU) was done. The duration of anuria varied between 12 to 72 hours. At the end of the procedure, ureteral stent was systematically left in place in all patients. Surgery was performed 6-12 hours after admission to hospital. Patients were followed at least 1 month postoperatively. The stone free rates (SFR) were determined as baseline, on the first post-operative day, and as overall on the 30 days after procedure. The greatest success was achieved in the distal localization of stones up to 10 mm (93%). Renal function returned in 51 (83.6%) patients within 7 days. In 18 (29.5%) patients [18 (20%) UU] we performed second procedure as extracorporeal shockwave lithotripsy in 16.7% and open surgery in 2.2%. In 43 (70.5%) patients URSL was a successful therapeutic approach in dealing with pain, obstruction and calculus. Calculus anuria is a medical emergency that requires rapid diagnosis and prompt treatment for the purpose of decompression. URSL is the proper method of choice for selected patients and can be performed safely and has high success rates with minimal morbidity.

  15. Migrated Hem-o-Lok clips in the ureter: a rare cause of recurrent urinary tract infection.

    PubMed

    Shrivastava, Prashant; Nayak, Brusabhanu; Singh, Prabhjot

    2017-02-15

    Erosion of surgical materials into the adjacent organs following surgical procedures is a rare complication. Migrations of these surgical materials into the urinary tract like pelvicalyceal system, ureter and bladder have been reported following various urological procedures. We present a case of migrated Hem-o-Lok clips into the ureter following a laparoscopic partial nephrectomy for angiomyolipoma of the left kidney presented with recurrent urinary tract infection. The case was managed with ureteroscopic removal of clips. The patient is asymptomatic on last follow-up. 2017 BMJ Publishing Group Ltd.

  16. Spontaneous dissolution of a guaifenesin stone.

    PubMed

    Nguyen, Thai T; Fallon, Bernard; Winfield, Howard N

    2005-08-01

    Guaifenesin is a commonly used expectorant whose use may lead to the occasional formation of guaifenesin urinary stones. We herein describe a patient who was taking 2400 mg Guaifenesin per day as part of his treatment for asthma. He had a past history of a guaifenesin stone removed ureteroscopically. His current presentation was with a 9 mm by 6 mm stone in the upper left ureter, seen on CT scan, and treated initially with a ureteral stent and hydration. After 3 weeks, the stone had disappeared, as confirmed by repeat CT scan. The genesis and treatment of guaifenesin stones is discussed.

  17. Temporomandibular joint arthroscopy technique using a single working cannula.

    PubMed

    Srouji, S; Oren, D; Zoabi, A; Ronen, O; Zraik, H

    2016-11-01

    The traditional arthroscopy technique includes the creation of three ports in order to enable visualization, operation, and arthrocentesis. The aim of this study was to assess an advanced temporomandibular joint (TMJ) arthroscopy technique that requires only a single cannula, through which a one-piece instrument containing a visualization canal, irrigation canal, and a working canal is inserted, as an alternative to the traditional double-puncture technique. This retrospective study assessed eight patients (13 TMJs) with pain and/or limited range of movement that was refractory to conservative therapy, who were treated between June 2015 and December 2015. The temporomandibular joint disorder (TMD) was diagnosed by physical examination and mouth opening measurements. The duration of surgery was recorded and compared to that documented for traditional arthroscopies performed by the same surgeon. Operative single-cannula arthroscopy (OSCA) was performed using a holmium YAG (Ho:YAG) 230μm fibre laser for ablation. The OSCA technique proved effective in improving mouth opening in all patients (mean increase 9.12±1.96mm) and in reducing pain (mean visual analogue scale decrease of 3.25±1.28). The operation time was approximately half that of the traditional technique. The OSCA technique is as efficient as the traditional technique, is simple to learn, and is simpler to execute. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Rigid ureteroscopy in children: Our experience

    PubMed Central

    Sripathi, Venkat; Chowdhary, Sujit K.; Kandpal, Deepak K.; Sarode, Varun V.

    2014-01-01

    Aim: To report our experience of Pediatric ureterorenoscopy for ureteric calculi from two tertiary Pediatric urology centers at Apollo Children's Hospital, Chennai and Indraprastha Apollo Hospital, New Delhi. Material and methods: All children who presented with symptomatic ureteric stones greater than 6 mm were entered into the study. All children less than 12 months and more than 18 years of age and those who underwent ureterorenoscopy for indications other than the stones were excluded from the study. The children were managed on a fixed investigative and treatment protocol. The data from the Apollo Hospital New Delhi and Apollo Children's Hospital Chennai was analysed. Results: There were a total of thirty eight children, twenty in Chennai and eighteen in the New Delhi study. The mean age was 10.4 years and 8.5 years and the youngest child was14 months and 24 months in the Chennai and New Delhi group respectively. There was one conversion to open surgery in either group. Pneumatic lithotripter was used in majority of cases and holmium laser in select children. Conclusion: This is the largest Indian series of ureterorenoscopy for ureteric calculi in children. This study over nearly a decade confirms the safety and efficacy of this technique even in young children. In children less than five years, prestenting and delayed ureterorenoscopy allows safe endoscopic treatment of ureteric calculi. PMID:25197190

  19. Use of renal resistive index and semi-rigid ureteroscopy for managing symptomatic persistent hydronephrosis during pregnancy.

    PubMed

    Atar, Murat; Bozkurt, Yasar; Soylemez, Haluk; Penbegul, Necmettin; Sancaktutar, Ahmet Ali; Bodakci, Mehmet Nuri; Hatipoglu, Namik Kemal; Hamidi, Cihad; Ozler, Ali

    2012-01-01

    The aim of this study was to evaluate the use of Doppler ultrasonography (DUS) and semi-rigid ureteroscopy (URS) for managing symptomatic persistent hydronephrosis during pregnancy. The study included 19 pregnant patients with unilateral symptomatic persistent hydronephrosis. All pregnant patients were assessed with conventional ultrasonography (US) followed by DUS for both kidneys. The mean patient age was 26 years (range 19-40), and the gestational period was 24 weeks (range 16-33). There was a significantly higher mean resistive index in the kidneys with ureteral obstruction than in the contralateral normal kidneys. Spinal anesthesia was performed on 18 patients, while general anesthesia was performed on 1 patient. Endoscopically stones were found in 17 patients (89.5%), while no stone was found in 2 patients (10.5%). The stones were fragmented by holmium laser and retracted with forceps. After lithotripsy, a ureteral JJ stent was inserted in 8 of 17 (47%) patients with ureteral stones. Intraoperatively, there were no obstetric complications, while ureteral perforation was seen in one patient. Two patients are still pregnant at the time of this writing, and 17 babies were born normally. Both RI and ΔRI increase in unilateral symptomatic persistent hydronephrosis during pregnancy. Semi-rigid URS can be used successfully for diagnosis and treatment in these patients. Copyright © 2012 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  20. Rare Earth Element Concentrations in Geothermal Wells at the Puna Geothermal Field, Hawaii

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, Andrew; Zierenberg, Robert

    Rare earth element concentrations in the geothermal wells at the Puna geothermal field, Hawaii. Samples taken from geothermal wells KS-5, KS-6W, KS-9W, KS-14E, and KS-16N. Includes pH and concentrations for Cerium, Dysprosium, Erbium, Europium, Gadolinium, Holmium, Lanthanum, Lutetium, Neodymium, Praseodymium, Samarium, Terbium, Thulium, Yttrium, and Ytterbium. Samples collected on November 11-17, 2016.

  1. The Synthesis and Characterization of Some Rare Earth Arsenides.

    DTIC Science & Technology

    1987-09-10

    particular, handling contaminants such as sodium , calcium and potassium can be monitored as well as hydrogen and oxygen content from oxide and hydroxide...trace quantities. Exceptional sensitivities (ppm) can be obtained for easily ionizable elements such as sodium , calcium, potassium, etc. This method of...holmium then reacts with the silica container wall, forming silicide and oxide products. The Nd melt reacts with the container as well. In the longer

  2. Fourier spectroscopy with a one-million-point transformation

    NASA Technical Reports Server (NTRS)

    Connes, J.; Delouis, H.; Connes, P.; Guelachvili, G.; Maillard, J.; Michel, G.

    1972-01-01

    A new type of interferometer for use in Fourier spectroscopy has been devised at the Aime Cotton Laboratory of the National Center for Scientific Research (CNRS), Orsay, France. With this interferometer and newly developed computational techniques, interferograms comprising as many as one million samples can now be transformed. The techniques are described, and examples of spectra of thorium and holmium, derived from one million-point interferograms, are presented.

  3. Amphiphilic complexes of Ho(iii), Dy(iii), Tb(iii) and Eu(iii) for optical and high field magnetic resonance imaging.

    PubMed

    Harris, Michael; Henoumont, Céline; Peeters, Wannes; Toyouchi, Shuichi; Vander Elst, Luce; Parac-Vogt, Tatjana N

    2018-05-29

    Lanthanides, holmium(iii), dysprosium(iii), and terbium(iii), were coordinated to an amphiphilic DOTA bis-coumarin derivative and then further assembled with an amphiphilic europium(iii) DTPA bis-coumarin derivative into mono-disperse micelles. The self-assembled micelles were characterized and assessed for their potential as bimodal contrast agents for high field magnetic resonance and optical imaging applications. All micelles showed a high transverse relaxation (r2) of 46, 34, and 30 s-1 mM-1 at 500 MHz and 37 °C for Dy(iii), Ho(iii) and Tb(iii), respectively, which is a result of the high magnetic moment of these lanthanides and the long rotational correlation time of the micelles. The quantum yield in aqueous solution ranged from 1.8% for Tb/Eu to 1.4% for Dy/Eu and 1.0% for the Ho/Eu micelles. Multi-photon excited emission spectroscopy has shown that due to the two-photon absorption of the coumarin chromophore the characteristic Eu(iii) emission could be observed upon excitation at 800 nm, demonstrating the usefulness of the system for in vivo fluorescence imaging applications. To the best of our knowledge, this is the first example reporting the potential of a holmium(iii) chelate as a negative MRI contrast agent.

  4. Impact of shock wave pattern and cavitation bubble size on tissue damage during ureteroscopic electrohydraulic lithotripsy.

    PubMed

    Vorreuther, R; Corleis, R; Klotz, T; Bernards, P; Engelmann, U

    1995-03-01

    It is known that electrohydraulic lithotripsy (EHL) during ureteroscopy may cause ureteral damage. To evaluate this trauma potential, find its mechanism and make it possible to avoid it, our research employed photographic evaluation, tissue studies, shock wave measurements and disintegration tests. The setup included a 3.3 F probe attached to an experimental generator with adjustable voltages and capacities providing energies from 25 mJ. to 1300 mJ. per pulse. In general, we distinguish between two traumatic mechanisms: (1) After placing the probe directly on the mucosa the rapid initial plasma penetrates the tissue resulting in a small, nonthermal, punched-like defect, whose depth depends on the energy applied. This trauma has minor clinical implications and is avoided by maintaining a minimum safety distance of 1 mm.; (2) According to physics, each plasma is followed by a cavitation bubble. The maximum size of this bubble depends on the energy applied and ranges from 3 mm. (25 mJ) to > 15 mm. (1300 mJ). In proportion to the bubble size, the ureteral wall may be distended or disrupted, even when the probe is not in direct contact with the mucosa. Therefore, the goal should be to obtain a low energy pressure pulse with high disintegration efficacy. Our evaluation of the pressure waves revealed that the selection of a high voltage and a low capacity leads to short and steep "laser-like" pulses. These pulses have a significant higher impact on stone disintegration than the broader pulses of the same energy provided by currently available generators.

  5. Single use disposable digital flexible ureteroscopes: an ex-vivo assessment and cost analysis.

    PubMed

    Hennessey, D B; Fojecki, G; Papa, N; Lawrentschuk, N; Bolton, D

    2018-04-15

    The single use flexible ureteroscope (fURS), the LithoVue is an important recent development. We aim to measure the capability of this instrument and to assess if there is a benefit to switching to single use instruments. The LithoVue was compared to Olympus URF-V and Stortz Flex Xc ex-vivo. An analysis of reusable fURS usage was performed to evaluate damage, durability and maintenance costs. This was then compared to the projected costs of using single use instruments. Flexion, deflection and irrigation flow of the LithoVue was equivalent, if not better than reusable instruments. An analysis of 234 procedures with 7 new Olympus URF-V scopes, revealed 15 scope damages. Staghorn stones and lower pole/midzone stones were significant risk factors for damage, p=0.014. Once damage occurred, it was likely to occur again. Total repair costs were $162,628 (£92,411), the mean cost per case is $695 (£395). Factoring in the purchase cost, cleaning and repair costs, and the cumulative cost of 28 reusable fURS cases is approximately $50,000 (£28,412). If the LithoVue was priced at $1200 AUD, switching to a single use scope would cost approximately $35,000 (£19,888). The LithoVue is analogous to reusable fURS scopes in regard to standard technical metrics. Depending on its purchase cost it may also represent a cost saving for hospitals when compared to the cumulative costs of maintaining reusable fURS. Additionally, urologist may consider to use the scope in cases in which reusable scope damage is anticipated. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    PubMed

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P <.0001). Significant variabilities in specimen size (P = .001), the presence of intact urothelium (P = .008), and crush artifact (P = .028) were found among the biopsy devices. The quality of specimens from backloaded cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Effects of pulsed electromagnetic fields on benign prostate hyperplasia.

    PubMed

    Giannakopoulos, Xenophon K; Giotis, Christos; Karkabounas, Spyridon Ch; Verginadis, Ioannis I; Simos, Yannis V; Peschos, Dimitrios; Evangelou, Angelos M

    2011-12-01

    Benign prostate hyperplasia (BPH) has been treated with various types of electromagnetic radiation methods such as transurethral needle ablation (TUNA), interstitial laser therapy (ILC), holmium laser resection (HoLRP). In the present study, the effects of a noninvasive method based on the exposure of patients with BPH to a pulsative EM Field at radiofrequencies have been investigated. Twenty patients with BPH, aging 68-78 years old (y.o), were enrolled in the study. Patients were randomly divided into two groups: the treatment group (10 patients, 74.0 ± 5.7 y.o) treated with the α-blocker Alfusosin, 10 mg/24 h for at least 4 weeks, and the electromagnetic group (10 patients, 73.7 ± 6.3 y.o) exposed for 2 weeks in a very short wave duration, pulsed electromagnetic field at radiofrequencies generated by an ion magnetic inductor, for 30 min daily, 5 consecutive days per week. Patients of both groups were evaluated before and after drug and EMF treatment by values of total PSA and prostatic PSA fraction, acid phosphate, U/S estimation of prostate volume and urine residue, urodynamic estimation of urine flow rate, and International Prostate Symptom Score (IPSS). There was a statistically significant decrease before and after treatment of IPSS (P < 0.02), U/S prostate volume (P < 0.05), and urine residue (P < 0.05), as well as of mean urine flow rate (P < 0.05) in patients of the electromagnetic group, in contrast to the treatment group who had only improved IPSS (P < 0.05). There was also a significant improvement in clinical symptoms in patients of the electromagnetic group. Follow-up of the patients of this group for one year revealed that results obtained by EMFs treatment are still remaining. Pulsed electromagnetic field at radiofrequencies may benefit patients with benign prostate hyperplasia treated by a non-invasive method.

  8. Experimental application of pulsed Ho:YAG laser-induced liquid jet as a novel rigid neuroendoscopic dissection device.

    PubMed

    Ohki, Tomohiro; Nakagawa, Atsuhiro; Hirano, Takayuki; Hashimoto, Tokitada; Menezes, Viren; Jokura, Hidefumi; Uenohara, Hiroshi; Sato, Yasuhiko; Saito, Tsutomu; Shirane, Reizo; Tominaga, Teiji; Takayama, Kazuyoshi

    2004-01-01

    Although water jet technology has been considered as a feasible neuroendoscopic dissection methodology because of its ability to perform selective tissue dissection without thermal damage, problems associated with continuous use of water and the ensuing fountain-effect-with catapulting of the tissue-could make water jets unsuitable for endoscopic use, in terms of safety and ease of handling. Therefore, the authors experimented with minimization of water usage during the application of a pulsed holmium:yttrium-aluminum-garnet (Ho:YAG) laser-induced liquid jet (LILJ), while assuring the dissection quality and the controllability of a conventional water jet dissection device. We have developed the LILJ generator for use as a rigid neuroendoscope, discerned its mechanical behavior, and evaluated its dissection ability using the cadaveric rabbit ventricular wall. The LILJ generator is incorporated into the tip of a stainless steel tube (length: 22 cm; internal diameter: 1.0 mm; external diameter: 1.4 mm), so that the device can be inserted into a commercial, rigid neuroendoscope. Briefly, the LILJ is generated by irradiating an internally supplied water column within the stainless steel tube using the pulsed Ho:YAG laser (wave length: 2.1 microm, pulse duration time: 350 microseconds) and is then ejected through the metal nozzle (internal diameter: 100 microm). The Ho:YAG laser pulse energy is conveyed through optical quartz fiber (core diameter: 400 microm), while cold water (5 degrees C) is internally supplied at a rate of 40 ml/hour. The relationship between laser energy (range: 40-433 mJ/pulse), standoff distance (defined as the distance between the tip of the optical fiber and the nozzle end; range: 10-30 mm), and the velocity, shape, pressure, and average volume of the ejected jet were analyzed by means of high-speed camera, PVDF needle hydrophone, and digital scale. The quality of the dissection plane, the preservation of blood vessels, and the penetration depth were evaluated using five fresh cadaveric rabbit ventricular walls, under neuroendoscopic vision. Jet velocity (7.0-19.6 m/second) and pressure (0.07-0.28 MPa) could be controlled by varying the laser energy, which determined the penetration depth in the cadaveric rabbit ventricular wall (0.07-1.30 mm/shot). The latter could be cut into desirable shapes-without thermal effects-under clear neuroendoscopic vision. The average volume of a single ejected jet could be confined to 0.42-1.52 microl/shot, and there was no accompanying generation of shock waves. Histological specimens revealed a sharp dissection plane and demonstrated that blood vessels of diameter over 100 microm could be preserved, without thermal damage. The present pulsed LILJ system holds promise as a safe and reliable dissection device for deployment in a rigid neuroendoscope. Copyright 2004 Wiley-Liss, Inc.

  9. In vitro investigations of propulsion during laser lithotripsy using video tracking.

    PubMed

    Eisel, Maximilian; Ströbl, Stephan; Pongratz, Thomas; Strittmatter, Frank; Sroka, Ronald

    2018-04-01

    Ureteroscopic laser lithotripsy is an important and widely used method for destroying ureter stones. It represents an alternative to ultrasonic and pneumatic lithotripsy techniques. Although these techniques have been thoroughly investigated, the influence of some physical parameters that may be relevant to further improve the treatment results is not fully understood. One crucial topic is the propulsive stone movement induced by the applied laser pulses. To simplify and speed up the optimization of laser parameters in this regard, a video tracking method was developed in connection with a vertical column setup that allows recording and subsequently analyzing the propulsive stone movement in dependence of different laser parameters in a particularly convenient and fast manner. Pulsed laser light was applied from below to a cubic BegoStone phantom loosely guided within a vertical column setup. The video tracking method uses an algorithm to determine the vertical stone position in each frame of the recorded scene. The time-dependence of the vertical stone position is characterized by an irregular series of peaks. By analyzing the slopes of the peaks in this signal it was possible to determine the mean upward stone velocity for a whole pulse train and to compare it for different laser settings. For a proof of principle of the video tracking method, a specific pulse energy setting (1 J/pulse) was used in combination with three different pulse durations: short pulse (0.3 ms), medium pulse (0.6 ms), and long pulse (1.0 ms). The three pulse durations were compared in terms of their influence on the propulsive stone movement in terms of upward velocity. Furthermore, the propulsions induced by two different pulse energy settings (0.8 J/pulse and 1.2 J/pulse) for a fixed pulse duration (0.3 ms) were compared. A pulse repetition rate of 10 Hz was chosen for all experiments, and for each laser setting, the experiment was repeated on 15 different freshly prepared stones. The latter set of experiments was compared with the results of previous propulsion measurements performed with a pendulum setup. For a fixed pulse energy (1 J/pulse), the mean upward propulsion velocity increased (from 120.0 to 154.9 mm · s -1 ) with decreasing pulse duration. For fixed pulse duration (0.3 ms), the mean upward propulsion velocity increased (from 91.9 to 123.3 mm · s -1 ) with increasing pulse energy (0.8 J/pulse and 1.2 J/pulse). The latter result corresponds roughly to the one obtained with the pendulum setup (increase from 61 to 105 mm · s -1 ). While the mean propulsion velocities for the two different pulse energies were found to differ significantly (P < 0.001) for the two experimental and analysis methods, the standard deviations of the measured mean propulsion velocities were considerably smaller in case of the vertical column method with video tracking (12% and 15% for n = 15 freshly prepared stones) than in case of the pendulum method (26% and 41% for n = 50 freshly prepared stones), in spite of the considerably smaller number of experiment repetitions ("sample size") in the first case. The proposed vertical column method with video tracking appears advantageous compared to the pendulum method in terms of the statistical significance of the obtained results. This may partly be understood by the fact that the entire motion of the stones contributes to the data analysis, rather than just their maximum distance from the initial position. The key difference is, however, that the pendulum method involves only one single laser pulse in each experiment run, which renders this method rather tedious to perform. Furthermore, the video tracking method appears much better suited to model a clinical lithotripsy intervention that utilizes longer series of laser pulses at higher repetition rates. The proposed video tracking method can conveniently and quickly deliver results for a large number of laser pulses that can easily be averaged. An optimization of laser settings to achieve minimal propulsive stone movement should thus be more easily feasible with the video tracking method in connection with the vertical column setup. Lasers Surg. Med. 50:333-339, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  10. NRL Review, 2008

    DTIC Science & Technology

    2008-01-01

    submicron powders in situ. Facilities to process powder into bulk specimens by hot and cold isostatic pressing permit a variety of consolidation...two types of nanoparticles, (YxHo1–x)2O3 and Cu - Ba-Ho-Y (exact stoichiometry yet to be determined), are formed during the deposition process ... Properties by Tailor- ing Nanoparticles in Holmium-doped YBa 2 Cu 3 O 7-d Superconductors 187 Molecular Memory Circuits Using a Virus as a Template 189

  11. Huge maternal hydronephrosis: a rare complication in pregnancy.

    PubMed

    Peng, Hsiu-Huei; Wang, Chin-Jung; Yen, Chih-Feng; Chou, Chien-Chung; Lee, Chyi-Long

    2003-06-10

    A huge maternal hydronephrosis is uncommon in pregnancy and might be mistaken as a pelvic mass. A 21-year-old primigravida was noted at 25th week of gestation to have a visible bulging mass on her left flank. The mass was originally mistaken as a large ovarian cyst but later proved to be a huge hydronephrosis. Retrograde insertion of ureteroscope and a ureteric stent failed, so we performed repeated ultrasound-guided needle aspiration to decompress the huge hydronephrosis, which enabled the patient to proceed to a successful term vaginal delivery. Nephrectomy was performed after delivery and proved the diagnosis of congenital ureteropelvic junction obstruction.

  12. Rare Earth Element Concentrations from Wells at the Don A. Campbell Geothermal Plant, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, Andrew; Zierenberg, Robert

    * Requires permission of originators for use. Rare earth element concentrations in thermal springs from the wells at the Don A. Campbell geothermal plant, Nevada. Samples taken from geothermal wells 85-11, 65-11, 54-11, and 64-11. Includes pH and concentrations for Cerium, Dysprosium, Erbium, Europium, Gadolinium, Holmium, Lanthanum, Lutetium, Neodymium, Praseodymium, Samarium, Terbium, Thulium, Yttrium, and Ytterbium. Samples from Don A. Campbell, Nevada collected on October 14, 2016.

  13. Smile effect detection for dispersive hypersepctral imager based on the doped reflectance panel

    NASA Astrophysics Data System (ADS)

    Zhou, Jiankang; Liu, Xiaoli; Ji, Yiqun; Chen, Yuheng; Shen, Weimin

    2012-11-01

    Hyperspectral imager is now widely used in many regions, such as resource development, environmental monitoring and so on. The reliability of spectral data is based on the instrument calibration. The smile, wavelengths at the center pixels of imaging spectrometer detector array are different from the marginal pixels, is a main factor in the spectral calibration because it can deteriorate the spectral data accuracy. When the spectral resolution is high, little smile can result in obvious signal deviation near weak atmospheric absorption peak. The traditional method of detecting smile is monochromator wavelength scanning which is time consuming and complex and can not be used in the field or at the flying platform. We present a new smile detection method based on the holmium oxide panel which has the rich of absorbed spectral features. The higher spectral resolution spectrometer and the under-test imaging spectrometer acquired the optical signal from the Spectralon panel and the holmium oxide panel respectively. The wavelength absorption peak positions of column pixels are determined by curve fitting method which includes spectral response function sequence model and spectral resampling. The iteration strategy and Pearson coefficient together are used to confirm the correlation between the measured and modeled spectral curve. The present smile detection method is posed on our designed imaging spectrometer and the result shows that it can satisfy precise smile detection requirement of high spectral resolution imaging spectrometer.

  14. Evaluation of fluid absorption during holmium laser enucleation of prostate by breath ethanol technique.

    PubMed

    Shah, Hemendra N; Kausik, Vikram; Hegde, Sunil; Shah, Jignesh N; Bansal, Manish B

    2006-02-01

    In a prospective manner we studied various factors affecting fluid absorption during HoLEP. We also simultaneously evaluated changes in serum electrolytes and hemoglobin decrease during HoLEP. This prospective study comprised of 53 patients who underwent HoLEP at our institute. Irrigation fluid was normal saline tagged with ethanol (1% w/v). Intraoperatively a standard breath analyzer was used to monitor expired breath ethanol levels during the procedure at 10-minute intervals. Patients who absorbed irrigating fluid as indicated by positive intraoperative breath tests were considered absorbers. Serum electrolyte and hemoglobin estimations were done before and after surgery. Total irrigation time, amount of irrigation fluid used, weight of resected tissue and presence of capsular perforation were recorded. Statistical analysis was performed to observe the effects of various factors on the amount of intraoperative fluid absorption. Of 53 patients studied 14 (26.41%) demonstrated fluid absorption in the range of 213 to 930 ml (mean 459). Preoperative prostate weight, total irrigation time, amount of irrigation fluid used and resected tissue weight were all significantly greater in absorbers. Similarly, absorbers had a statistically significant decrease in hemoglobin level postoperatively. There was no statistically significant change in serum electrolytes between absorbers and nonabsorbers. Preoperative weight of prostate, total irrigation time, amount of irrigation fluid used and weight of resected tissue all directly influence the amount of fluid absorption during HoLEP. There is no significant change in serum electrolytes and no risk of the transurethral resection syndrome.

  15. Analysis of Er{sup 3+} and Ho{sup 3+} codoped fluoroindate glasses as wide range temperature sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haro-Gonzalez, P., E-mail: patharo@ull.es; Leon-Luis, S.F.; Gonzalez-Perez, S.

    2011-07-15

    Graphical abstract: The sensor sensitivity as a function of the temperature of erbium and holmium doped fluoroindate glasses. A wide temperature range from 20 K to 425 K is covered with a sensitivity larger than 0.0005. Highlights: {yields} The FIR technique has been carried out in fluoroindate glass sample. {yields} The Er doped fluoroindate sample has a maximum sensitivity of 0.0028 K{sup -1} at 425 K. {yields} The Ho doped fluoroindate sample has a maximum sensitivity of 0.0036 K{sup -1} at 59 K. -- Abstract: The fluorescence intensity ratio technique for two fluoroindate glass samples has been carried out. Themore » green emissions at 523 nm and at 545 nm in a 0.1 mol% of Er{sup 3+} doped fluoroindate glass was studied in a wide range of temperature from 125 K to 425 K with a maximum sensitivity of 0.0028 K{sup -1} for 425 K. In a sample doped with 0.1 mol% of Ho{sup 3+} the emissions at 545 nm and at 750 nm were analyzed as a function of temperature from 20 K to 300 K obtaining a maximum sensitivity of 0.0036 K{sup -1} at 59 K. Using both fluoroindate glass samples a wide temperature range from 20 K to 425 K is easily covered pumping with two low-cost diode laser at 406 nm and 473 nm.« less

  16. Efficacy of endoscopic combined intrarenal surgery in the prone split-leg position for staghorn calculi.

    PubMed

    Hamamoto, Shuzo; Yasui, Takahiro; Okada, Atsushi; Koiwa, Satoshi; Taguchi, Kazumi; Itoh, Yasunori; Kawai, Noriyasu; Hashimoto, Yoshihiro; Tozawa, Keiichi; Kohri, Kenjiro

    2015-01-01

    Abstract Purpose: To evaluate the efficacy of endoscopic combined intrarenal surgery (ECIRS) using retrograde flexible ureteroscopy and miniature percutaneous nephrolithotomy (PNL) for the treatment of patients with staghorn calculi in the prone split-leg position. We retrospectively reviewed the records of 42 patients with staghorn calculi (45.8±3.2 mm) who underwent ECIRS using retrograde flexible ureteroscopy and miniature PNL in the prone split-leg position for the treatment of staghorn calculi in our center between December 2010 and August 2013. A flexible ureteroscope with a laser fiber was inserted through a ureteral access sheath, and lithoclast lithotripsy was performed through a mini-percutaneous tract. Both procedures were performed simultaneously by two urologists. Surgical parameters, including surgical time, stone-free (SF) rates, modified Clavien complication grades, and risk factors for residual stones, were analyzed. Fifteen patients (35.7%) had complete staghorn calculi. Among the 42 staghorn calculi treated, 23 had 0 to 5 stone branches, 14 had 6 to 10 stone branches, and 5 had ≥11 stone branches. All procedures were performed successfully using a single lithotripsy tract with the patient in the prone split-leg position. The mean surgical time was 143.2±9.2 minutes. The initial SF rate was 71.4%, and the final SF rate was 83.3% after further treatment. One patient required a blood transfusion (2.4%), but no patient experienced a ≥3 Clavien grade complication. Risk factors for residual stones were stone size, stone surface area, complete staghorn calculi, and the number of stone branches. ECIRS for staghorn calculi in the prone split-leg position is a safe, efficient, and versatile method for the effective management of staghorn calculi without the creation of multiple percutaneous tracts.

  17. Study of holmium (III) and yttrium(III) with DOTA complexes as candidates for radiopharmaceutical use

    NASA Astrophysics Data System (ADS)

    Ernestová, M.; Jedináková-Křížová, V.

    2003-01-01

    Reaction conditions for complexation of radionuclides with DOTA were studied using thinlayer chromatography (TLC), paper chromatography (PC) and potentiometry. It was found that all of the studied complexes can reach very high radiochemical yield about 95%. Optimal conditions for obtaining such high radiochemical yields are as follows: pH higher than 4 and the excess of chelating agent must be minimally 3∶1. Potentiometric study showed that the formation of complexes is characterised by very slow kinetics.

  18. On the specific electrophysical properties of n-InSe single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdinov, A. Sh., E-mail: abdinov-axmed@yahoo.com; Babaeva, R. F., E-mail: babaeva-rena@yandex.ru; Rzaev, R. M., E-mail: abdinov-axmed@yandex.ru

    2016-01-15

    The temperature dependences of physical parameters (the conductivity and the Hall constant) are experimentally investigated for pure indium-selenide (n-InSe) crystals and those lightly doped with rareearth elements (gadolinium, holmium, and dysprosium). It is established that the obtained results depend on the origin of the samples under investigation and prove to be contradictory for different samples. The obtained experimental results are treated taking into account the presence of chaotic large-scale defects and drift barriers caused by them in these samples.

  19. Water Quality Data from Two Agricultural Drainage Basins in Northwestern Indiana and Northeastern Illinois: I. Lagrangian and Synoptic Data, 1999-2002

    DTIC Science & Technology

    2004-01-01

    of 370 °C with sulfuric acid , potassium sulfate and mercury (II). Therefore, in this report, Kjeldahl nitrogen refers to ammonium ions plus organic... sulfuric acid to a fixed point endpoint according to the techniques of Kramer (1982) using a Gran’s titration calculation. Standard reference water...Name Al Aluminum H Hydrogen Rb Rubidium As Arsenic HCO 3 Bicarbonate Re Rhenium B Boron Hg Mercury S Sulfur Ba Barium Ho Holmium SO 4

  20. Emittance Theory for Thin Film Selective Emitter

    NASA Technical Reports Server (NTRS)

    Chubb, Donald L.; Lowe, Roland A.; Good, Brian S.

    1994-01-01

    Thin films of high temperature garnet materials such as yttrium aluminum garnet (YAG) doped with rare earths are currently being investigated as selective emitters. This paper presents a radiative transfer analysis of the thin film emitter. From this analysis the emitter efficiency and power density are calculated. Results based on measured extinction coefficients for erbium-YAG and holmium-YAG are presented. These results indicated that emitter efficiencies of 50 percent and power densities of several watts/sq cm are attainable at moderate temperatures (less than 1750 K).

  1. Pulsed laser-induced liquid jet: evolution from shock/bubble interaction to neurosurgical application

    NASA Astrophysics Data System (ADS)

    Nakagawa, A.; Kumabe, T.; Ogawa, Y.; Hirano, T.; Kawaguchi, T.; Ohtani, K.; Nakano, T.; Sato, C.; Yamada, M.; Washio, T.; Arafune, T.; Teppei, T.; Atsushi, K.; Satomi, S.; Takayama, K.; Tominaga, T.

    2017-01-01

    The high-speed liquid (water) jet has distinctive characteristics in surgical applications, such as tissue dissection without thermal damage and small blood vessel preservation, that make it advantageous over more conventional instruments. The continuous pressurized jet has been used since the first medical application of water jets to liver surgery in the 1980s, but exhibited drawbacks partly related to the excess water supply required and unsuitability for application to microsurgical instruments intended for deep, narrow lesions (endoscopic instrumentation and catheters) due to limitations in miniaturization of the device. To solve these issues, we initiated work on the pulsed micro-liquid jet. The idea of the pulsed micro-liquid jet originated from the observation of tissue damage by shock/bubble interactions during extracorporeal shock wave lithotripsy and evolved into experimental application for recanalization of cerebral embolisms in the 1990s. The original method of generating the liquid jet was based on air bubble formation and microexplosives as the shock wave source, and as such could not be applied clinically. The air bubble was replaced by a holmium:yttrium-aluminum-garnet (Ho:YAG) laser-induced bubble. Finally, the system was simplified and the liquid jet was generated via irradiation from the Ho:YAG laser within a liquid-filled tubular structure. A series of investigations revealed that this pulsed laser-induced liquid jet (LILJ) system has equivalent dissection and blood vessel preservation characteristics, but the amount of liquid usage has been reduced to less than 2 μ l per shot and can easily be incorporated into microsurgical, endoscopic, and catheter devices. As a first step in human clinical studies, we have applied the LILJ system for the treatment of skull base tumors through the transsphenoidal approach in 9 patients (7 pituitary adenomas and 2 chordomas), supratentorial glioma (all high grade glioma) in 8 patients, including one with fine perforating vessel involvement, and cerebrovascular disease (1 arteriovenous malformation and 2 intracerebral hemorrhages) in 3 patients. Precise dissection and mass reduction of the tumor were obtained in all tumor cases except for one chordoma with significant fibrosis. Small arteries down to 100 μ m were preserved, allowing subsequent microsurgical devascularization. Veins were also preserved occasionally. The arachnoid membrane and the tumor capsule were resistant to the LILJ except for one case with prolonged exposure. No complications related to use of the LILJ system were observed. No disturbance of the surgical field by splashing, aerosol, or dissemination of pathological tissue occurred with placement of the optimal suction system. The Ho:YAG LILJ system enhances the advantages of commercialized pressure-driven continuous liquid jet instrumentation in terms of small vessel preservation and accessibility in confined spaces for minimally invasive neurosurgery, and solves some of the drawbacks involved with excessive liquid use and size.

  2. A New Alternative for Difficult Ureter in Adult Patients: No Need to Dilate Ureter via a Balloon or a Stent with the Aid of 4.5F Semirigid Ureteroscope.

    PubMed

    Söylemez, Haluk; Yıldırım, Kadir; Utangac, Mehmet Mazhar; Aydoğan, Tahsin Batuhan; Ezer, Mehmet; Atar, Murat

    2016-06-01

    To investigate the effectivity of 4.5F ultrathin ureteroscope (UT-URS) without any need for active or passive dilation in the treatment of adult patient population in whom ureteral orifices cannot be engaged using conventional URS. Among a total of 512 adult patients who had undergone URS between April 2012 and November 2015 in our department for diagnostic or therapeutic purposes, 43 (8.4%) patients required ureteral dilation because we could not engage ureteral orifice. In adult patients in whom we could not engage ureteral orifice with 7.5F and 8F semirigid URS, we tried to complete the operation using 4.5F UT-URS without resorting to dilation. Age and gender of the patients, indication for operation, stone size, location, operative times, laterality of stone(s), stone-free rates, length of hospital stay, and complications were recorded. Mean age of the patients was 34.5 ± 11.2 (21-66) years. The patients had undergone operations for ureteral stone (n = 39), unexplained hydronephrosis (n = 2), and ureteral stenosis (n = 2). Mean stone size was 8.2 ± 2.3 (4-18) mm. Mean operative time was 64.2 ± 13.5 minutes. In 37 of 39 patients, a complete stone-free rate (94.8%) was achieved. Mean length of hospital stay was 8.9 ± 5.8 hours. It has been demonstrated that in an adult patient population in whom ureteral orifices cannot be engaged using conventional URS, ureteral access could be achieved with 4.5F UT-URS without any need for dilation. At the same time, use of 4.5F UT-URS resulted in an acceptable treatment success and lower complication rates in most of these patients without the need for a second session.

  3. Evidence for strong Breit interaction in dielectronic recombination of highly charged heavy ions.

    PubMed

    Nakamura, Nobuyuki; Kavanagh, Anthony P; Watanabe, Hirofumi; Sakaue, Hiroyuki A; Li, Yueming; Kato, Daiji; Currell, Fred J; Ohtani, Shunsuke

    2008-02-22

    Resonant strengths have been measured for dielectronic recombination of Li-like iodine, holmium, and bismuth using an electron beam ion trap. By observing the atomic number dependence of the state-resolved resonant strength, clear experimental evidence has been obtained that the importance of the generalized Breit interaction (GBI) effect on dielectronic recombination increases as the atomic number increases. In particular, it has been shown that the GBI effect is exceptionally strong for the recombination through the resonant state [1s2s(2)2p(1/2)](1).

  4. [Calculus formation in the prostatic cavity after transurethral resection of the prostate: causes, treatment and prevention].

    PubMed

    Wei, Zhi-Feng; Xu, Xiao-Feng; Cheng, Wen; Zhou, Wen-Quan; Ge, Jing-Ping; Zhang, Zheng-Yu; Gao, Jian-Ping

    2012-05-01

    To study the causes, clinical manifestations, treatment and prevention of calculus that develops in the prostatic cavity after transurethral resection of the prostate. We reported 11 cases of calculus that developed in the prostatic cavity after transurethral resection or transurethral plasmakinetic resection of prostate. The patients complained of repeated symptoms of frequent micturition, urgent micturition and urodynia after operation, accompanied with urinary tract infection and some with urinary obstruction, which failed to respond to anti-infective therapies. Cystoscopy revealed calculi in the prostatic cavity, with eschar, sphacelus, uneven wound surface and small diverticula in some cases. After diagnosis, 1 case was treated by holmium laser lithotripsy and a second transurethral resection of the prostate, while the other 10 had the calculi removed under the cystoscope, followed by 1 -2 weeks of anti-infective therapy. After treatment, all the 11 cases showed normal results of routine urinalysis, and no more symptoms of frequent micturition, urgent micturition and urodynia. Three- to six-month follow-up found no bladder irritation symptoms and urinary tract infection. Repeated symptoms of frequent micturition, urgent micturition, urodynia and urinary tract infection after transurethral resection of the prostate should be considered as the indicators of calculus in the prostatic cavity, which can be confirmed by cystoscopy. It can be treated by lithotripsy or removal of the calculus under the cystoscope, or even a second transurethral resection of the prostate. For its prevention, excessive electric coagulation and uneven wound surface should be avoided and anti-infection treatment is needed.

  5. [Causes and management for male urethral stricture].

    PubMed

    Chen, Caifang; Zeng, Mingqiang; Xue, Ruizhi; Wang, Guilin; Gao, Zhiyong; Yuan, Wuxiong; Tang, Zhengyan

    2018-05-28

    To explore the etiology of male urethral stricture, analyze the therapeutic strategies of urethral stricture, and summarize the complicated cases.
 Methods: The data of 183 patients with urethral stricture were retrospectively analyzed, including etiology, obstruction site, stricture length, therapeutic strategy, and related complications.
 Results: The mean age was 49.7 years, the average course was 64.7 months, and the constituent ratio of 51 to 65 years old patients was 38.8% (71/183). The traumatic injury of patients accounted for 52.4% (96/183), in which the pelvic fracture accounted for 35.5% (65/183) and the straddle injury accounted for 16.9% (31/183). There were 54 cases of iatrogenic injury (29.5%). The posterior urethral stricture accounted for 45.9% (84/183), followed by the anterior urethral stricture (44.8%, 82/183) and the stenosis (6.6%, 12/183). A total of 99 patients (54.1%) received the end to end anastomosis, and 40 (21.9%) were treated with intracavitary surgery, such as endoscopic holmium laser, cold knife incision, endoscopic electroknife scar removal, balloon dilation, and urethral dilation. In the patients over 65-years old, the urethral stricture rate was 14.8% and the complication rate (70.4%) for transurethral resection of the prostate (TURP) was significantly higher than that of all samples (P<0.01).
 Conclusion: Both the etiology of male urethral stricture and the treatment strategy have changed and the incidence of traumatic and iatrogenic urethral stricture has increased in recent 3 years. The main treatment of urethral stricture has been transformed from endoscopic surgery into urethroplasty.

  6. MINI PCNL in a Pediatric Population

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wah, Tze M., E-mail: Tze.Wah@leedsth.nhs.uk; Kidger, Lizi; Kennish, Steven

    2013-02-15

    We report our initial experience of MINI percutaneous nephrolithotomy (PCNL) in a pediatric population using a miniature nephroscope through a 16F metal access sheath. All pediatric patients who underwent PCNL from August 2007 to September 2010 using a 14F miniature nephroscope through a 16F metal access sheath for renal stone extraction were evaluated. Patients' demographic details, procedural information, and posttreatment outcomes were prospectively documented. A total of 23 MINI PCNLs were performed on 23 kidneys of 12 patients whose ages ranged from 1.6 to 14.6 years. The median stone burden was 3.44 cm{sup 2}, and there were 11 'Staghorn' stones.more » The procedure was primary via a single puncture in 19 kidneys and secondary using a preexisting nephrostomy tract in 4 kidneys. Access was successful in all primary and two secondary cases, for a total of success rate of 91.3%. Stones were fragmented using a Holmium laser and/or lithoclast, and fragments were irrigated or sequentially removed by various stone grasping devices. The mean procedural X-ray screening time and total stone extraction period were 4.5 and 109.4 min, respectively. The primary stone free rate was 83.6 %, which increased to 90.5 % after treating the residual fragments. Postoperative hydrothorax developed in one patient, which required a chest drain. Symptoms of chest infection and positive urine culture were detected in one and two patients, respectively. Our initial experience supports previous reports that MINI PCNL is safe and effective for the management of renal stones in children.« less

  7. Therapy-resistant nephrolithiasis following renal artery coil embolization

    PubMed Central

    2013-01-01

    Background Transcatheter renal artery embolization is an effective and minimally invasive treatment option for acute renal bleeding. Early post-interventional complications include groin hematoma, incomplete embolization, coil misplacement and coil migration. Late complications are rare and mostly related to coil migration. Case presentation A 22-year-old woman with a history of recurrent stone disease and a lumbal meningomyelocele underwent bilateral open pyelolithotomy for bilateral staghorn calculi. Post-operatively, acute hemorrhage of the left kidney occurred and selective arterial coil embolization of a lower pole interlobular renal artery was performed twice. Four years after this intervention the patient presented with a new 15.4 mm stone in the lower calyx of the left kidney. After two extracorporeal shock wave lithotripsy treatments disintegration of the stone was not detectable. Therefore, flexible ureterorenoscopy was performed and revealed that the stone was adherent to a partially intraluminal metal coil in the lower renal calyx. The intracalyceal part of the coil and the adherent stone were successfully removed using the holmium laser. Conclusion Therapy-resistant nephrolithiasis was caused by a migrated metal coil, which was placed four years earlier for the treatment of acute post-operative renal bleeding. Renal coils in close vicinity to the renal pelvis can migrate into the collecting system and trigger renal stone formation. Extracorporeal shock wave lithotripsy seems to be inefficient for these composite stones. Identification of these rare stones is possible during retrograde intrarenal surgery. It also enables immediate stone disintegration and removal of the stone fragments and the intraluminal coil material. PMID:23758632

  8. Biodegradable seeds of holmium don't change neurological function after implant in brain of rats.

    PubMed

    Diniz, Mirla Fiuza; Ferreira, Diogo Milioli; de Lima, Wanderson Geraldo; Pedrosa, Maria Lucia; Silva, Marcelo Eustáquio; de Almeida Araujo, Stanley; Sampaio, Kinulpe Honorato; de Campos, Tarcisio Passos Ribeiro; Siqueira, Savio Lana

    2017-01-01

    To evaluate the surgical procedure and parenchymal abnormalities related to implantation of ceramic seeds with holmium-165 in rats' brain. An effective method of cancer treatment is brachytherapy in which radioactive seeds are implanted in the tumor, generating a high local dose of ionizing radiation that can eliminate tumor cells while protecting the surrounding healthy tissue. Biodegradable Ho 166 -ceramic-seeds have been addressed recently. The experiments in this study were approved by the Ethics Committee on Animal Use at the Federal University of Ouro Preto, protocol number 2012/034. Twenty-one adult Fischer rats were divided into Naive Group, Sham Group and Group for seed implants (ISH). Surgical procedures for implantation of biodegradable seeds were done and 30 days after the implant radiographic examination and biopsy of the brain were performed. Neurological assays were also accomplished to exclude any injury resulting from either surgery or implantation of the seeds. Radiographic examination confirmed the location of the seeds in the brain. Neurological assays showed animals with regular spontaneous activity. The histological analysis showed an increase of inflammatory cells in the brain of the ISH group. Electron microscopy evidenced cytoplasmic organelles to be unchanged. Biochemical analyzes indicate there was neither oxidative stress nor oxidative damage in the ISH brain. CAT activity showed no difference between the groups as well as lipid peroxidation measured by TBARS. The analysis of the data pointed out that the performed procedure is safe as no animal showed alterations of the neurological parameters and the seeds did not promote histological architectural changes in the brain tissue.

  9. catena-Poly[[[tetra­kis(μ-2-butenoato)dicopper(II)]-μ-2-butenoato-[diaqua­(2-butenoato)holmium(III)]-di-μ-2-butenoato-[diaqua­(2-butenoato)holmium(III)]-μ-2-butenoato] trihydrate

    PubMed Central

    Perec, Mireille; Garland, Maria Teresa; Baggio, Ricardo

    2008-01-01

    The title compound {[Cu2Ho2(C4H5O2)10(H2O)4]·3H2O}n, is a one-dimensional 3d/4f organic–inorganic hybrid complex, the HoIII member of the isotypic lanthanoid series with Ln = GdIII, ErIII and YIII. The structure shows an alternation of Cu2 and Ho2 dinuclear units bridged by the ligands and hydrogen bonds only. The chains are composed of Cu2 classical dinuclear η1:η1:μ2 fourfold bridges [Cu⋯Cu = 2.6417 (9) Å] and of Ho2 units bridged by two η2:η1:μ2 carboxyl­ate units. This results in distorted square-based pyramidal CuO5 units and irregular HoO9 units. The alternating Cu2 and Ho2 units are bridged into linear arrays along the a axis by a set of one η2:η1:μ2 carboxyl­ate O atom and two hydrogen bonds with Cu⋯Ho separations of 4.4883 (10) and 4.5086 (10) Å. The distance between adjacent chains, as calculated by the closest and furthest distances between two chains, covers the range 10–14 Å. The H atoms of the water mol­ecules could not be located, but the O⋯O separations for these species suggest the presence of O—H⋯O hydrogen bonds. PMID:21580901

  10. Retrograde Endourological Management of Upper Urinary Tract Abnormalities in Patients with Ileal Conduit Urinary Diversion: A Dual-Center Experience.

    PubMed

    Olson, Louise; Satherley, Hywel; Cleaveland, Paul; Zelhof, Bachar; Mokete, Max; Neilson, Donald; Srirangam, Shalom

    2017-09-01

    Patients with ileal conduit urinary diversions are at an increased risk of long-term upper urinary tract (UUT) complications, including anastomotic strictures, infections, and urolithiasis. The reconstructed urinary system poses challenges for endoscopic manipulation. We present and describe our dual-center experience in performing retrograde ureteroscopy to treat or diagnose UUT abnormalities in patients with ileal conduit incontinent diversion. We performed a retrospective analysis of medical records for all patients with previous urinary diversion who underwent retrograde ureteroscopic procedures via the ileal loop in our institutions over a 9 year period (between June 2007 and August 2016). Fifty-four procedures were performed in 36 patients. Mean age was 61 (28-90) years. Average time from diversion to ureteroscopic procedure was 13.0 (0.08-53) years. Stone disease was the most common indication for intervention in 35.2% (19/54) of cases, with a stone-free rate of 78.9% (15/19). Other indications included surveillance of transitional-cell carcinoma in 22.2% (12/54), diagnostic flexible ureteroscopy (fURS) in 20.4% (11/54), stricture management in 11.1% (6/54), removal of encrusted stent/nephrostomy in 7.4% (4/54), urine leak after diversion in 1.9% (1/54), and miscellaneous in 1.9% (1/54). Successful retrograde access was possible in 74% (40/54) of cases. A long and tortuous ileal segment, too difficult to negotiate, was the most common cause of failure to access the UUT. In 13 out of 54 (24.1%) cases, retrograde fURS was combined with simultaneous percutaneous antegrade access. Six patients (11.1%) developed postprocedural pyrexia requiring additional antibiotic therapy, and one (1.9%) patient required embolization of the renal artery for ongoing bleeding. Median length of stay was 1 day (0-55), with 13 (24%) being performed as day-case procedures. Retrograde ureteroscopy in patients with ileal conduits can be technically challenging due to distorted anatomy. This procedure can be safely performed in experienced hands with standard endourological equipment. An antegrade approach can be carried out simultaneously, which may be required in a small number of patients.

  11. Endockscope: using mobile technology to create global point of service endoscopy.

    PubMed

    Sohn, William; Shreim, Samir; Yoon, Renai; Huynh, Victor B; Dash, Atreya; Clayman, Ralph; Lee, Hak J

    2013-09-01

    Recent advances and the widespread availability of smartphones have ushered in a new wave of innovations in healthcare. We present our initial experience with Endockscope, a new docking system that optimizes the coupling of the iPhone 4S with modern endoscopes. Using the United States Air Force resolution target, we compared the image resolution (line pairs/mm) of a flexible cystoscope coupled to the Endockscope+iPhone to the Storz high definition (HD) camera (H3-Z Versatile). We then used the Munsell ColorChecker chart to compare the color resolution with a 0° laparoscope. Furthermore, 12 expert endoscopists blindly compared and evaluated images from a porcine model using a cystoscope and ureteroscope for both systems. Finally, we also compared the cost (average of two company listed prices) and weight (lb) of the two systems. Overall, the image resolution allowed by the Endockscope was identical to the traditional HD camera (4.49 vs 4.49 lp/mm). Red (ΔE=9.26 vs 9.69) demonstrated better color resolution for iPhone, but green (ΔE=7.76 vs 10.95), and blue (ΔE=12.35 vs 14.66) revealed better color resolution with the Storz HD camera. Expert reviews of cystoscopic images acquired with the HD camera were superior in image, color, and overall quality (P=0.002, 0.042, and 0.003). In contrast, the ureteroscopic reviews yielded no statistical difference in image, color, and overall (P=1, 0.203, and 0.120) quality. The overall cost of the Endockscope+iPhone was $154 compared with $46,623 for a standard HD system. The weight of the mobile-coupled system was 0.47 lb and 1.01 lb for the Storz HD camera. Endockscope demonstrated feasibility of coupling endoscopes to a smartphone. The lighter and inexpensive Endockscope acquired images of the same resolution and acceptable color resolution. When evaluated by expert endoscopists, the quality of the images overall were equivalent for flexible ureteroscopy and somewhat inferior, but still acceptable for flexible cystoscopy.

  12. Endockscope: Using Mobile Technology to Create Global Point of Service Endoscopy

    PubMed Central

    Sohn, William; Shreim, Samir; Yoon, Renai; Huynh, Victor B.; Dash, Atreya; Clayman, Ralph

    2013-01-01

    Abstract Background and Purpose Recent advances and the widespread availability of smartphones have ushered in a new wave of innovations in healthcare. We present our initial experience with Endockscope, a new docking system that optimizes the coupling of the iPhone 4S with modern endoscopes. Materials and Methods Using the United States Air Force resolution target, we compared the image resolution (line pairs/mm) of a flexible cystoscope coupled to the Endockscope+iPhone to the Storz high definition (HD) camera (H3-Z Versatile). We then used the Munsell ColorChecker chart to compare the color resolution with a 0° laparoscope. Furthermore, 12 expert endoscopists blindly compared and evaluated images from a porcine model using a cystoscope and ureteroscope for both systems. Finally, we also compared the cost (average of two company listed prices) and weight (lb) of the two systems. Results Overall, the image resolution allowed by the Endockscope was identical to the traditional HD camera (4.49 vs 4.49 lp/mm). Red (ΔE=9.26 vs 9.69) demonstrated better color resolution for iPhone, but green (ΔE=7.76 vs 10.95), and blue (ΔE=12.35 vs 14.66) revealed better color resolution with the Storz HD camera. Expert reviews of cystoscopic images acquired with the HD camera were superior in image, color, and overall quality (P=0.002, 0.042, and 0.003). In contrast, the ureteroscopic reviews yielded no statistical difference in image, color, and overall (P=1, 0.203, and 0.120) quality. The overall cost of the Endockscope+iPhone was $154 compared with $46,623 for a standard HD system. The weight of the mobile-coupled system was 0.47 lb and 1.01 lb for the Storz HD camera. Conclusion Endockscope demonstrated feasibility of coupling endoscopes to a smartphone. The lighter and inexpensive Endockscope acquired images of the same resolution and acceptable color resolution. When evaluated by expert endoscopists, the quality of the images overall were equivalent for flexible ureteroscopy and somewhat inferior, but still acceptable for flexible cystoscopy. PMID:23701228

  13. The modern history and evolution of percutaneous nephrolithotomy.

    PubMed

    Patel, Sutchin R; Nakada, Stephen Y

    2015-02-01

    Serendipity, innovative physicians, evolving techniques for renal access, and improvements in equipment and radiology led to the evolution of percutaneous nephrolithotomy (PCNL). We searched urology texts and the literature for sources pertaining to the history and development of PCNL. In 1941, Rupel and Brown performed the first nephroscopy when a rigid cystoscope was passed into the kidney following open surgery. Willard Goodwin, in 1955, while trying to perform a renal arteriogram, placed a needle into the collecting system of a hydronephrotic kidney and performed the first antegrade nephrostogram. He left a tube to drain the kidney, thereby placing the first nephrostomy tube. By 1976, Fernström and Johansson were the first to describe a technique for extracting renal calculi through a percutaneous nephrostomy under radiological control. In 1978, Arthur Smith, would describe the first antegrade stent placement when he introduced a Gibbons stent through a percutaneous nephrostomy in a patient with a reimplanted ureter. Dr. Smith would coin the term "endourology" to describe closed, controlled manipulation of the genitourinary tract. His collaboration with Kurt Amplatz, an interventional radiologist and medical inventor, would lead to numerous innovations that would further advance PCNL. In the 1980s the process of renal access and tract dilation was improved upon and the use of a rigid cystoscope was replaced by offset nephroscopes with a large straight working channel. Radiographic innovations, including improvements in fluoroscopy would further aid in renal access. The development of various lithotripsy devices and the introduction of the holmium laser improved the efficiency of stone fragmentation and clearance. The increased clinical experience and utilization of PCNL would lead to the characterization of stone-free rates and complications for the procedure. Serendipity, innovations in renal access, optics, radiology, and improvements in lithotripsy all contributed to the modern day PCNL.

  14. A multicenter, randomized, controlled trial of transureteral and shock wave lithotripsy--which is the best minimally invasive modality to treat distal ureteral calculi in children?

    PubMed

    Basiri, Abbas; Zare, Samad; Tabibi, Ali; Sharifiaghdas, Farzaneh; Aminsharifi, Alireza; Mousavi-Bahar, Seyed Habibollah; Ahmadnia, Hassan

    2010-09-01

    Since there is insufficient evidence to determine the best treatment modality in children with distal ureteral calculi, we designed a multicenter, randomized, controlled trial to evaluate the efficacy and complications of transureteral and shock wave lithotripsy in these patients. A total of 100 children with distal ureteral calculi were included in the study. Of the patients 50 were randomized consecutively to undergo shock wave lithotripsy using a Compact Delta II lithotriptor (Dornier MedTech, Kennesaw, Georgia), and 50 were randomized to undergo transureteral lithotripsy with holmium laser and pneumatic lithotriptor between February 2007 and October 2009. Stone-free, complication and efficiency quotient rates were assessed in each group. Mean +/- SD patient age was 6.5 +/- 3.7 years (range 1 to 13). Mean stone surface was 35 mm(2) in the transureteral group and 37 mm(2) in the shock wave lithotripsy group. Stone-free rates at 2 weeks after transureteral lithotripsy and single session shock wave lithotripsy differed significantly, at 78% and 56%, respectively (p = 0.004). With 2 sessions of shock wave lithotripsy the stone-free rate increased to 72%. Efficiency quotient was significantly higher for transureteral vs shock wave lithotripsy (81% vs 62%, p = 0.001). Minor complications were comparable and negligible between the groups. Two patients (4%) who underwent transureteral lithotripsy sustained a ureteral perforation. In the short term it seems that transureteral and shock wave lithotripsy are acceptable modalities for the treatment of distal ureteral calculi in children. However, transureteral lithotripsy has a higher efficacy rate when performed meticulously by experienced hands using appropriate instruments. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. [HoLEP learning curve: Toward a standardised formation and a team strategy].

    PubMed

    Baron, M; Nouhaud, F-X; Delcourt, C; Grise, P; Pfister, C; Cornu, J-N; Sibert, L

    2016-09-01

    Holmium laser enucleation of prostate (HoLEP) is renowned for the difficulty of its learning curve. Our aim was to evaluate the interest of a three-step tutorial in the HoLEP learning curve, in a university center. It is a retrospective, monocentric study of the 82 first procedures done consecutively by the same operator with a proctoring in early experience and after 40 procedures. For all patients were noted: enucleation efficiency (g/min), morcellation efficiency (g/min), percentage of enucleated tissue (enucleated tissue/adenome weigth evaluated by ultrasonography. g/g), perioperative morbidity (Clavien), length of hospital stay, length of urinary drainage, functional outcomes at short and middle term (Qmax, post-void residual volume [PVR], QOL scores and IPSS at 3 and 6months). Enucleation and morcellation efficiency were significantly higher after the second proctoring (0.87 vs 0.44g/min; P<0.0001 and 4.2 vs 3.37g/min, P=0.038, respectively) so as the prostatic volume (43.5 vs 68.1mL, P=0.0001). Percentage of enucleated tissue was higher in the second group, however, the difference was not significant (69.5% vs 80.4%, P=0.03). Per- and postoperative complications, hospital length of stay, urinary drainage length and functional results at 3 and 6months were not significantly different. The learning curve did not interfere with functional results. The second proctoring was essential to us in order to grasp the technique. These data underlined the necessity of a pedagogic reflexion in order to built a standardized formation technique to the HoLEP. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Super-mini percutaneous nephrolithotomy (SMP): a new concept in technique and instrumentation.

    PubMed

    Zeng, Guohua; Wan, ShawPong; Zhao, Zhijian; Zhu, Jianguo; Tuerxun, Aierken; Song, Chao; Zhong, Liang; Liu, Ming; Xu, Kewei; Li, Hulin; Jiang, Zhiqiang; Khadgi, Sanjay; Pal, Shashi K; Liu, Jianjun; Zhang, Guoxi; Liu, Yongda; Wu, Wenqi; Chen, Wenzhong; Sarica, Kemal

    2016-04-01

    To present a novel miniature endoscopic system designed to improve the safety and efficacy of percutaneous nephrolithotomy, named the 'super-mini percutaneous nephrolithotomy' (SMP). The endoscopic system consists of a 7-F nephroscope with enhanced irrigation and a modified 10-14 F access sheath with a suction-evacuation function. This system was tested in patients with renal stones of <2.5 cm, in a multicentre prospective non-randomised clinical trial. In all, 146 patients were accrued in 14 centres. Nephrostomy tract dilatation was carried out to 10-14 F. The lithotripsy was performed using either a Holmium laser or pneumatic lithotripter. A nephrostomy tube or JJ stent was placed only if clinically indicated. SMP was completed successfully in 141 of 146 patients. Five patients required conversion to larger nephrostomy tracts. The mean (sd) stone size was 2.2 (0.6) cm and the mean operative duration was 45.6 min. The initial stone-free rate (SFR) was 90.1%. The SFR at the 3-month follow-up was 95.8%. Three patients required auxiliary procedures for residual stones. Complications occurred in 12.8% of the patients, all of which were Clavien grade ≤II and no transfusions were needed. In all, 72.3% of the patients did not require any kind of catheter, while 19.8% had JJ stents and 5.7% had nephrostomy tubes placed. The mean hospital stay was 2.1 days. SMP is a safe and effective treatment for renal stones of <2.5 cm. SMP may be particularly suitable for patients with lower pole stones and stones that ae not amenable to retrograde intrarenal surgery. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  17. The spectrum of pelvic fracture urethral injuries and posterior urethroplasty in an Italian high-volume centre, from 1980 to 2013.

    PubMed

    Barbagli, Guido; Sansalone, Salvatore; Romano, Giuseppe; Lazzeri, Massimo

    2015-03-01

    To describe the emergency and delayed treatment of patients with pelvic fracture urethral injuries (PFUI) presenting to an Italian high-volume centre. In a retrospective, observational study we evaluated the spectrum of PFUI and posterior urethroplasty in an Italian high-volume centre, from 1980 to 2013. Patients requiring emergency treatment for PFUI and delayed treatment for pelvic fracture urethral defects (PFUD) were included. Patients with incomplete clinical records were excluded from the study. Descriptive statistical methods were applied. In all, 159 male patients (median age 35 years) were included in the study. A traffic accident was the most frequent (42.8%) cause of PFUI, and accidents at work were reported as the cause of trauma in 34% of patients. Agricultural accidents decreased from 24.4% to 6.2% over the course of the survey. A suprapubic cystostomy was the most frequent (49%) emergency treatment in patients with PFUI. The use of surgical realignment decreased from 31.7% to 6.2%, and endoscopic realignment increased from 9.7% to 35.3%. A bulbo-prostatic anastomosis was the most frequent (62.9%) delayed treatment in patients with PFUD. The use of the Badenoch pull-through decreased from 19.5% to 2.6%, and endoscopic holmium laser urethrotomy increased from 4.9% to 32.7%. The spectrum of PFUI and subsequent treatment of PFUD has changed greatly over the last 10 years at our centre. These changes involved patient age, aetiology, emergency and delayed treatments, and were found to be related to changes in the economy and lifestyle of the Italian patients.

  18. Retrograde Intrarenal Surgery for Symptomatic Renal Sinus Cysts: Long-Term Results and Literature Review.

    PubMed

    Mancini, Vito; Cormio, Luigi; d'Altilia, Nicola; Benedetto, Giuseppe; Ferrarese, Paolo; Balzarro, Matteo; Defidio, Lorenzo; Carrieri, Giuseppe

    2018-05-02

    To report the long-term multicenter experience with retrograde intrarenal holmium-laser incision (RIR-HoLI) in the management of symptomatic renal sinus cysts (RSCs). In the literature, RIR-HoLI has been shown to be a safe and effective treatment, but there are only a few reports regarding long-term results and reproducibility of this procedure. From June 2010 to June 2015, 14 patients with symptomatic RSCs underwent RIR-HoLI. The mean age was 52.1 ± 11.28 years (range 28-77) and the mean cyst size was 53.2 ± 14.23 mm (range 35-90). In all cases, contrast-enhanced computer tomography (CT) showed compression of the renal pelvis by the cyst (no malignancy). Surgical outcome was assessed in terms of symptoms improvement (measured by Visual Analogue Scale [VAS] for pain) and renal ultrasound findings at 3-6-12 months postoperatively and then yearly. CT scan was carried out at 12 months follow-up. RIR-HoLI was successful in all patients. The mean operative time was 47.8 ± 13.54 min (range 30-80) and mean hospital stay was 3.5 days (range 2-5). There were 2 Clavien grade II complications (flank pain and urgency delaying discharge). After surgery, all patients -became asymptomatic (VAS score change, p = 0.0001). One patient had persistence of a small cyst (10 mm). Mean follow-up is 44 ± 17.24 months (range 24-84); all patients remained asymptomatic, with no signs of recurrence. RIR-HoLI proved to be a safe and effective treatment for symptomatic RSCs. In our experience, it provided excellent long-term results and was reproducible at 4 different -institutions. © 2018 S. Karger AG, Basel.

  19. Matched pair analysis of ureteroscopy vs. shock wave lithotripsy for the treatment of upper ureteric calculi.

    PubMed

    Stewart, G D; Bariol, S V; Moussa, S A; Smith, G; Tolley, D A

    2007-05-01

    There is controversy over whether shock wave lithotripsy (SWL) or ureteroscopy (URS) is the best management of ureteric calculi, especially for stones located in the upper ureter. This study compares URS and SWL management of upper ureteric stones directly for the first time using a different analysis tool, the matched pair analysis study design. This method enables meaningful comparisons to be made on a small number of matched patients, using precise like-for-like matching. Adult patients undergoing primary treatment of solitary radiopaque proximal ureteric stones were identified. Patients with stents, nephrostomies or stones at the pelvi-ureteric junction were excluded. Patients had a minimum of 3 months follow-up. Patients treated by primary URS were matched using four parameters (sex, laterality, stone size and location) to patients treated on a Dornier Compact Delta Lithotriptor. A total of 1479 patients had URS or SWL from which 27 upper ureteric stone matched pairs were identified. Three-month stone free rates were 82% for URS and 89% for SWL (McNemar's test, p=0.625). Re-treatment was required in 11% and 26% following URS and SWL respectively (p=0.219). Forty-one per cent of URS patients required an ancillary treatment, such as stent removal, compared with only 22% of SWL patients (p=0.227). Introduction of a holmium:YAG laser for use with URS improved the stone free rate for URS to 100%. Using a robust like-for-like comparison of similar patients with very similar upper ureteric stones the outcomes following SWL and URS were comparable. Choice of treatment should therefore be based on parameters such as availability of equipment, waiting times and patient preference.

  20. Flexible ureterorenoscopy for lower pole stones: influence of the collecting system's anatomy.

    PubMed

    Jessen, Jan Peter; Honeck, Patrick; Knoll, Thomas; Wendt-Nordahl, Gunnar

    2014-02-01

    The impact of renal anatomy on the success rate of flexible ureterorenoscopy (fURS) for lower pole stones is less clear than it is on shock wave lithotripsy, for which it is a recognized influence factor. We analyzed safety and efficiency of fURS using modern endoscopes for lower pole stones dependent on the collecting system's configuration. We retrospectively evaluated a consecutive sample of 111 fURS for lower pole stones at our tertiary care center between January 2010 and September 2012 from our prospectively kept database. All procedures were performed with modern flexible ureterorenoscopes, nitinol baskets, holmium laser lithotripsy, and ureteral access sheaths whenever needed. The infundibular length (IL) and width (IW) and infundibulopelvic angle (IPA) were measured and the data were stratified for stone-free status and complications classified by the Clavien-Dindo scale. Univariate and multifactorial statistical analyses were performed. Correlation of operation time (OR-time) with anatomical parameters was conducted. Ninety-eight (88.3%) of the 111 patients were stone free after a single fURS. On multifactorial analysis, the stone size and IL had significant influence on the stone-free rate (SFR) (p<0.01), whereas IW did not. An acute IPA (<30°) also had significant influence (p=0.01). The incidence of complications and OR-time were not influenced by the pelvicaliceal anatomy. fURS is a safe and efficient treatment option for lower pole kidney stones. A long infundibulum and a very acute IPA (<30°) negatively affect the SFR. However, with second look procedures, a complete stone clearance is achievable even in case of unfavorable anatomic conditions. A narrow infundibulum has no negative effect while using modern endoscopes. The complication rate is not affected by the collecting system's anatomy.

Top