Distributed pressure sensors for a urethral catheter.
Ahmadi, Mahdi; Rajamani, Rajesh; Timm, Gerald; Sezen, A S
2015-01-01
A flexible strip that incorporates multiple pressure sensors and is capable of being fixed to a urethral catheter is developed. The urethral catheter thus instrumented will be useful for measurement of pressure in a human urethra during urodynamic testing in a clinic. This would help diagnose the causes of urinary incontinence in patients. Capacitive pressure sensors are fabricated on a flexible polyimide-copper substrate using surface micromachining processes and alignment/assembly of the top and bottom portions of the sensor strip. The developed sensor strip is experimentally evaluated in an in vitro test rig using a pressure chamber. The sensor strip is shown to have adequate sensitivity and repeatability. While the calibration factors for the sensors on the strip vary from one sensor to another, even the least sensitive sensor has a resolution better than 0.1 psi.
Safety System for Controlling Fluid Flow into a Suction Line
NASA Technical Reports Server (NTRS)
England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)
2018-01-01
A safety system includes a sleeve fitted within a pool's suction line at its inlet. The sleeve terminates with a plate that resides within the suction line. The plate has holes formed therethrough. A housing defining distinct channels is fitted in the sleeve so that the distinct channels lie within the sleeve. Each of the distinct channels has a first opening on one end thereof and a second opening on another end thereof. The second openings reside in the sleeve. The first openings are in fluid communication with the water in the pool, and are distributed around a periphery of an area of the housing that prevents coverage of all the first openings when a human interacts therewith. A first sensor is coupled to the sleeve to sense pressure therein, and a second pressure sensor is coupled to the plate to sense pressure in one of the plates' holes.
Using arm and hand gestures to command robots during stealth operations
NASA Astrophysics Data System (ADS)
Stoica, Adrian; Assad, Chris; Wolf, Michael; You, Ki Sung; Pavone, Marco; Huntsberger, Terry; Iwashita, Yumi
2012-06-01
Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-offreedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.
Using Arm and Hand Gestures to Command Robots during Stealth Operations
NASA Technical Reports Server (NTRS)
Stoica, Adrian; Assad, Chris; Wolf, Michael; You, Ki Sung; Pavone, Marco; Huntsberger, Terry; Iwashita, Yumi
2012-01-01
Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-of-freedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.
77 FR 36146 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-18
... airplanes to the applicability. We are issuing this AD to prevent degradation of the electrical insulation... could cause the level sensor to heat above acceptable limits, possibly resulting in a fuel tank... connector sleeves materials fitted to the MTI units. Degradation of the electrical insulation sleeves of the...
76 FR 68671 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-07
... incorrect connector sleeves materials fitted to the MTI units. Degradation of the electrical insulation... condition, if not corrected, could cause the level sensor to heat above acceptable limits, possibly.... Degradation of the electrical insulation sleeves of the Low- level indication lamps on the MTI of the flight...
NASA Technical Reports Server (NTRS)
Tucker, Dennis Stephen (Inventor); Capo-Lugo, Pedro A. (Inventor)
2016-01-01
A single-axis accelerometer includes a housing defining a sleeve. An object/mass is disposed in the sleeve for sliding movement therein in a direction aligned with the sleeve's longitudinal axis. A first piezoelectric strip, attached to a first side of the object and to the housing, is longitudinally aligned with the sleeve's longitudinal axis. The first piezoelectric strip includes a first strip of a piezoelectric material with carbon nanotubes substantially aligned along a length thereof. A second piezoelectric strip, attached to a second side of the object and to the housing, is longitudinally aligned with the sleeve's longitudinal axis. The second piezoelectric strip includes a second strip of the piezoelectric material with carbon nanotubes substantially aligned along a length thereof. A voltage sensor is electrically coupled to at least one of the first and second piezoelectric strips.
Decoding static and dynamic arm and hand gestures from the JPL BioSleeve
NASA Astrophysics Data System (ADS)
Wolf, M. T.; Assad, C.; Stoica, A.; You, Kisung; Jethani, H.; Vernacchia, M. T.; Fromm, J.; Iwashita, Y.
This paper presents methods for inferring arm and hand gestures from forearm surface electromyography (EMG) sensors and an inertial measurement unit (IMU). These sensors, together with their electronics, are packaged in an easily donned device, termed the BioSleeve, worn on the forearm. The gestures decoded from BioSleeve signals can provide natural user interface commands to computers and robots, without encumbering the users hands and without problems that hinder camera-based systems. Potential aerospace applications for this technology include gesture-based crew-autonomy interfaces, high degree of freedom robot teleoperation, and astronauts' control of power-assisted gloves during extra-vehicular activity (EVA). We have developed techniques to interpret both static (stationary) and dynamic (time-varying) gestures from the BioSleeve signals, enabling a diverse and adaptable command library. For static gestures, we achieved over 96% accuracy on 17 gestures and nearly 100% accuracy on 11 gestures, based solely on EMG signals. Nine dynamic gestures were decoded with an accuracy of 99%. This combination of wearableEMGand IMU hardware and accurate algorithms for decoding both static and dynamic gestures thus shows promise for natural user interface applications.
Biosleeve Human-Machine Interface
NASA Technical Reports Server (NTRS)
Assad, Christopher (Inventor)
2016-01-01
Systems and methods for sensing human muscle action and gestures in order to control machines or robotic devices are disclosed. One exemplary system employs a tight fitting sleeve worn on a user arm and including a plurality of electromyography (EMG) sensors and at least one inertial measurement unit (IMU). Power, signal processing, and communications electronics may be built into the sleeve and control data may be transmitted wirelessly to the controlled machine or robotic device.
Control of a Glove-Based Grasp Assist Device
NASA Technical Reports Server (NTRS)
Bergelin, Bryan J (Inventor); Ihrke, Chris A. (Inventor); Davis, Donald R. (Inventor); Linn, Douglas Martin (Inventor); Sanders, Adam M (Inventor); Askew, R. Scott (Inventor); Laske, Evan (Inventor); Ensley, Kody (Inventor)
2015-01-01
A grasp assist system includes a glove and sleeve. The glove includes a digit, i.e., a finger or thumb, and a force sensor. The sensor measures a grasping force applied to an object by an operator wearing the glove. The glove contains a tendon connected at a first end to the digit. The sleeve has an actuator assembly connected to a second end of the tendon and a controller in communication with the sensor. The controller includes a configuration module having selectable operating modes and a processor that calculates a tensile force to apply to the tendon for each of the selectable operating modes to assist the grasping force in a manner that differs for each of the operating modes. A method includes measuring the grasping force, selecting the mode, calculating the tensile force, and applying the tensile force to the tendon using the actuator assembly.
Development of a system to measure local measurement conditions around textile electrodes.
Kim, Saim; Oliveira, Joana; Roethlingshoefer, Lisa; Leonhard, Steffen
2010-01-01
The three main influence factors on the interface between textile electrode an skin are: temperature, contact pressure and relative humidity. This paper presents first results of a prototype, which measures these local measurement conditions around textile electrodes. The wearable prototype is a data acquisition system based on a microcontroller with a flexible sensor sleeve. Validation measurements included variation of ambient temperature, contact pressures and sleeve material. Results show a good correlation with data found in literature.
NASA Astrophysics Data System (ADS)
Kuosheng, Jiang; Guanghua, Xu; Tangfei, Tao; Lin, Liang; Yi, Wang; Sicong, Zhang; Ailing, Luo
2014-01-01
This paper presents the theory and implementation of a novel sensor system for measuring the angular speed (AS) of a shaft rotating at a very low speed range, nearly zero speed. The sensor system consists mainly of an eccentric sleeve rotating with the shaft on which the angular speed to be measured, and an eddy current displacement sensor to obtain the profile of the sleeve for AS calculation. When the shaft rotates at constant speed the profile will be a pure sinusoidal trace. However, the profile will be a phase modulated signal when the shaft speed is varied. By applying a demodulating procedure, the AS can be obtained in a straightforward manner. The sensor system was validated experimentally based on a gearbox test rig and the result shows that the AS obtained are consistent with that obtained by a conventional encoder. However, the new sensor gives very smooth and stable traces of the AS, demonstrating its higher accuracy and reliability in obtaining the AS of the low speed operations with speed-up and down transients. In addition, the experiment also shows that it is easy and cost-effective to be realised in different applications such as condition monitoring and process control.
Eddy Current Sensing of Torque in Rotating Shafts
NASA Astrophysics Data System (ADS)
Varonis, Orestes J.; Ida, Nathan
2013-12-01
The noncontact torque sensing in machine shafts is addressed based on the stress induced in a press-fitted magnetoelastic sleeve on the shaft and eddy current sensing of the changes of electrical conductivity and magnetic permeability due to the presence of stress. The eddy current probe uses dual drive, dual sensing coils whose purpose is increased sensitivity to torque and decreased sensitivity to variations in distance between probe and shaft (liftoff). A mechanism of keeping the distance constant is also employed. Both the probe and the magnetoelastic sleeve are evaluated for performance using a standard eddy current instrument. An eddy current instrument is also used to drive the coils and analyze the torque data. The method and sensor described are general and adaptable to a variety of applications. The sensor is suitable for static and rotating shafts, is independent of shaft diameter and operational over a large range of torques. The torque sensor uses a differential eddy current measurement resulting in cancellation of common mode effects including temperature and vibrations.
Design of a Soft Robotic Elbow Sleeve with Passive and Intent-Controlled Actuation
Koh, Tze Hui; Cheng, Nicholas; Yap, Hong Kai; Yeow, Chen-Hua
2017-01-01
The provision of continuous passive, and intent-based assisted movements for neuromuscular training can be incorporated into a robotic elbow sleeve. The objective of this study is to propose the design and test the functionality of a soft robotic elbow sleeve in assisting flexion and extension of the elbow, both passively and using intent-based motion reinforcement. First, the elbow sleeve was developed, using elastomeric and fabric-based pneumatic actuators, which are soft and lightweight, in order to address issues of non-portability and poor alignment with joints that conventional robotic rehabilitation devices are faced with. Second, the control system was developed to allow for: (i) continuous passive actuation, in which the actuators will be activated in cycles, alternating between flexion and extension; and (ii) an intent-based actuation, in which user intent is detected by surface electromyography (sEMG) sensors attached to the biceps and triceps, and passed through a logic sequence to allow for flexion or extension of the elbow. Using this setup, the elbow sleeve was tested on six healthy subjects to assess the functionality of the device, in terms of the range of motion afforded by the device while in the continuous passive actuation. The results showed that the elbow sleeve is capable of achieving approximately 50% of the full range of motion of the elbow joint among all subjects. Next, further experiments were conducted to test the efficacy of the intent-based actuation on these healthy subjects. The results showed that all subjects were capable of achieving electromyography (EMG) control of the elbow sleeve. These preliminary results show that the elbow sleeve is capable of carrying out continuous passive and intent-based assisted movements. Further investigation of the clinical implementation of the elbow sleeve for the neuromuscular training of neurologically-impaired persons, such as stroke survivors, is needed. PMID:29118693
Kirby, Anna C; Tan-Kim, Jasmine; Nager, Charles W.
2015-01-01
Objectives Female stress urinary incontinence (SUI) is caused by urethral dysfunction during dynamic conditions, but current technology has limitations in measuring urethral pressures under dynamic conditions. An 8-French high resolution manometry catheter (HRM) currently in clinical use in gastroenterology may accurately measure urethral pressures under dynamic conditions because it has a 25ms response rate and circumferential pressure sensors along the length of the catheter (ManoScan® ESO, Given Imaging). We evaluated the concordance, repeatability, and tolerability of this catheter. Methods We measured resting, cough, and strain maximum urethral closure pressures (MUCPs) using HRM and measured resting MUCPs with water perfusion side-hole catheter urethral pressure profilometry (UPP) in 37 continent and 28 stress incontinent subjects. Maneuvers were repeated after moving the HRM catheter along the urethral length to evaluate whether results depend on catheter positioning. Visual analog pain scores evaluated the comfort of HRM compared to UPP. Results The correlation coefficient for resting MUCPs measured by HRM vs. UPP was high (r = 0.79, p<0.001). Repeatability after catheter repositioning was high for rest, cough, and strain with HRM: r= 0.92, 0.89, and 0.89. Mean MUCPs (rest, cough, strain) were higher in continent than incontinent subjects (all p < 0.001) and decreased more in incontinent subjects than continent subjects during cough and strain maneuvers compared to rest. Conclusions This preliminary study shows that HRM is concordant with standard technology, repeatable, and well tolerated in the urethra. Incontinent women have more impairment of their urethral closure pressures during cough and strain than continent women. PMID:25185595
Kirby, Anna C; Tan-Kim, Jasmine; Nager, Charles W
2015-01-01
Female stress urinary incontinence is caused by urethral dysfunction during dynamic conditions, but current technology has limitations in measuring urethral pressures under these conditions. An 8-French high-resolution manometry (HRM) catheter currently in clinical use in gastroenterology may accurately measure urethral pressures under dynamic conditions because it has a 25-millisecond response rate and circumferential pressure sensors along the length of the catheter (ManoScan ESO; Given Imaging, Yoqneam, Israel). We evaluated the concordance, repeatability, and tolerability of this catheter. We measured resting, cough, and strain maximum urethral closure pressures (MUCPs) using HRM and measured resting MUCPs with water-perfusion side-hole catheter urethral pressure profilometry (UPP) in 37 continent and 28 stress-incontinent subjects. Maneuvers were repeated after moving the HRM catheter along the urethral length to evaluate whether results depend on catheter positioning. Visual analog pain scores evaluated the comfort of HRM compared to UPP. The correlation coefficient for resting MUCPs measured by HRM versus UPP was high (r = 0.79, P < 0.001). Repeatability after catheter repositioning was high for rest, cough, and strain with HRM: r = 0.92, 0.89, and 0.89. Mean MUCPs (rest, cough, and strain) were higher in continent than in incontinent subjects (all P < 0.001) and decreased more in incontinent subjects than in continent subjects during cough and strain maneuvers compared to rest. This preliminary study shows that HRM is concordant with standard technology, repeatable, and well tolerated in the urethra. Incontinent women have more impairment of their urethral closure pressures during cough and strain than continent women.
Insulation Testing Using Cryostat Apparatus with Sleeve
NASA Technical Reports Server (NTRS)
Fesmire, J. E.; Augustynowicz, S. D.
1999-01-01
The method and equipment of testing continuously rolled insulation materials is presented in this paper. Testing of blanket and molded products is also facilitated. Materials are installed around a cylindrical copper sleeve using a wrapping machine. The sleeve is slid onto the vertical cold mass of the cryostat. The gap between the cold mass and the sleeve measures less than 1 mm. The cryostat apparatus is a liquid nitrogen boiloff calorimeter system that enables direct measurement of the apparent thermal conductivity (k-value) of the insulation system at any vacuum level between 5 x 10(exp -5) and 760 torr. Sensors are placed between layers of the insulation to provide complete temperature-thickness profiles. The temperatures of the cold mass (maintained at 77.8 kelvin (K)), the sleeve (cold boundary temperature (CBT)), the insulation outer surface (warm boundary temperature (WBT)), and the vacuum can (maintained at 313 K by a thermal shroud) are measured. Plots of CBT, WBT, and layer temperature profiles as functions of vacuum level show the transitions between the three dominant heat transfer modes. For this cryostat apparatus, the measureable heat gain is from 0.2 to 20 watts. The steady-state measurement of k-value is made when all temperatures and the boiloff rate are stable.
Instrumented urethral catheter and its ex vivo validation in a sheep urethra
NASA Astrophysics Data System (ADS)
Ahmadi, Mahdi; Rajamani, Rajesh; Timm, Gerald; Sezen, Serdar
2017-03-01
This paper designs and fabricates an instrumented catheter for instantaneous measurement of distributed urethral pressure profiles. Since the catheter enables a new type of urological measurement, a process for accurate ex vivo validation of the catheter is developed. A flexible sensor strip is first fabricated with nine pressure sensors and integrated electronic pads for an associated sensor IC chip. The flexible sensor strip and associated IC chip are assembled on a 7 Fr Foley catheter. A sheep bladder and urethra are extracted and used in an ex vivo set up for verification of the developed instrumented catheter. The bladder-urethra are suspended in a test rig and pressure cuffs placed to apply known static and dynamic pressures around the urethra. A significant challenge in the performance of the sensor system is the presence of parasitics that introduce large bias and drift errors in the capacitive sensor signals. An algorithm based on use of reference parasitic transducers is used to compensate for the parasitics. Extensive experimental results verify that the developed compensation method works effectively. Results on pressure variation profiles circumferentially around the urethra and longitudinally along the urethra are presented. The developed instrumented catheter will be useful in improved urodynamics to more accurately diagnose the source of urinary incontinence in patients.
Human Grasp Assist Device Soft Goods
NASA Technical Reports Server (NTRS)
Ihrke, Chris A. (Inventor); Davis, Donald R. (Inventor); Bergelin, Bryan (Inventor); Bridgwater, Lyndon B. J. (Inventor); Bibby, Heather (Inventor); Schroeder, Judy (Inventor); Linn, Douglas Martin (Inventor); Erkkila, Craig (Inventor)
2015-01-01
A grasp assist system includes a glove and a flexible sleeve. The glove includes a digit such as a finger or thumb, a force sensor configured to measure a grasping force applied to an object by an operator wearing the glove, and adjustable phalange rings positioned with respect to the digit. A saddle is positioned with respect to the finger. A flexible tendon is looped at one end around the saddle. A conduit contains the tendon. A conduit anchor secured within a palm of the glove receives the conduit. The sleeve has pockets containing an actuator assembly connected to another end of the tendon and a controller. The controller is in communication with the force sensor, and calculates a tensile force in response to the measured grasping force. The controller commands the tensile force from the actuator assembly to tension the tendon and thereby move the finger.
Spring/dimple instrument tube restraint
DeMario, Edmund E.; Lawson, Charles N.
1993-01-01
A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs.
Spring/dimple instrument tube restraint
DeMario, E.E.; Lawson, C.N.
1993-11-23
A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs. 7 figures.
Van den Kerckhove, Eric; Fieuws, Steffen; Massagé, Patrick; Hierner, Robert; Boeckx, Willy; Deleuze, Jean-Paul; Laperre, Jan; Anthonissen, Mieke
2007-08-01
This study investigated the reproducibility of repeated measurements with the Kikuhime pressure sensor under two different types of pressure garments used in the treatment and prevention of scars after burns. Also efficiency of garments was assessed in clinical circumstances by assessing pressure loss and residual pressure after 1 month. Intra- and inter-observer reproducibility and repeated measurements with 1-month time lapse were examined on 55 sites in 26 subjects by means of intra-class correlation coefficients and standard error of measurements. Results showed good to excellent ICC and low SEMs in the two conditions. There was a significant difference in pressure after 1 month between elastic tricot and weft knit garments, although evolution of pressure loss after 1 month was similar. Concerning different locations, there was a significant difference in pressure loss after 1 month between gloves and sleeves with the largest pressure loss for sleeves. Considering these results we concluded that the Kikuhime pressure sensor provides valid and reliable information and can be used in comparative clinical trials to evaluate pressure garments used in burn scar treatment. Secondly, elastic tricot garments in our study tended to have higher clinical pressures but both types of garments had similar pressure loss over time.
NASA Astrophysics Data System (ADS)
Dong, Bo; Han, Ming; Wang, Anbo
2012-06-01
A reliable and low-cost two-wavelength quadrature interrogating method has been developed to demodulate optical signals from diaphragm-based Fabry-Perot interferometric fiber optic sensors for multipoint partial discharge detection in power transformers. Commercial available fused-silica parts (a wafer, a fiber ferrule, and a mating sleeve) and a cleaved optical single mode fiber were bonded together to form an extrinsic Fabry-Perot acoustic sensor. Two lasers with center wavelengths separated by a quarter of the period of sensor interference fringes were used to probe acousticwave- induced diaphragm vibration. A coarse wavelength-division multiplexing (CWDM) add/drop multiplexer was used to separate the reflected two wavelengths before two photo detectors. Optical couplers were used to distribute mixed laser light to each sensor-detector module for multiplexing purpose. Sensor structure, detection system design and experiment results are presented.
Signal processing in urodynamics: towards high definition urethral pressure profilometry.
Klünder, Mario; Sawodny, Oliver; Amend, Bastian; Ederer, Michael; Kelp, Alexandra; Sievert, Karl-Dietrich; Stenzl, Arnulf; Feuer, Ronny
2016-03-22
Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI) which is a significant medical, social, and economic problem. Low spatial pressure resolution, common occurrence of artifacts, and uncertainties in data location limit the diagnostic value of UPP. To overcome these limitations, high definition urethral pressure profilometry (HD-UPP) combining enhanced UPP hardware and signal processing algorithms has been developed. In this work, we present the different signal processing steps in HD-UPP and show experimental results from female minipigs. We use a special microtip catheter with high angular pressure resolution and an integrated inclination sensor. Signals from the catheter are filtered and time-correlated artifacts removed. A signal reconstruction algorithm processes pressure data into a detailed pressure image on the urethra's inside. Finally, the pressure distribution on the urethra's outside is calculated through deconvolution. A mathematical model of the urethra is contained in a point-spread-function (PSF) which is identified depending on geometric and material properties of the urethra. We additionally investigate the PSF's frequency response to determine the relevant frequency band for pressure information on the urinary sphincter. Experimental pressure data are spatially located and processed into high resolution pressure images. Artifacts are successfully removed from data without blurring other details. The pressure distribution on the urethra's outside is reconstructed and compared to the one on the inside. Finally, the pressure images are mapped onto the urethral geometry calculated from inclination and position data to provide an integrated image of pressure distribution, anatomical shape, and location. With its advanced sensing capabilities, the novel microtip catheter collects an unprecedented amount of urethral pressure data. Through sequential signal processing steps, physicians are provided with detailed information on the pressure distribution in and around the urethra. Therefore, HD-UPP overcomes many current limitations of conventional UPP and offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct anatomical location. This could enable the development of focal therapy approaches in the treatment of SUI.
Simple refractometer based on in-line fiber interferometers
NASA Astrophysics Data System (ADS)
Esteban, Ó.; Martínez Manuel, R.; Shlyagin, M. G.
2015-09-01
A very simple but accurate optical fiber refractometer based on the Fresnel reflection in the fiber tip and two in-line low-reflective mirrors for light intensity referencing is reported. Each mirror was generated by connecting together 2 fiber sections with FC/PC and FC/APC connectors using the standard FC/PC mating sleeve. For the sensor interrogation, a standard DFB diode laser pumped with a sawtooth-wave current was used. A resolution of 6 x 10-4 was experimentally demonstrated using different liquids. A simple sensor construction and the use of low cost components make the reported system interesting for many applications.
Nuclear reactor flow control method and apparatus
Church, J.P.
1993-03-30
Method and apparatus for improving coolant flow in a nuclear reactor during accident as well as nominal conditions. The reactor has a plurality of fuel elements in sleeves and a plenum above the fuel and through which the sleeves penetrate. Holes are provided in the sleeve so that coolant from the plenum can enter the sleeve and cool the fuel. The number and size of the holes are varied from sleeve to sleeve with the number and size of holes being greater for sleeves toward the center of the core and less for sleeves toward the periphery of the core. Preferably the holes are all the same diameter and arranged in rows and columns, the rows starting from the bottom of every sleeve and fewer rows in peripheral sleeves and more rows in the central sleeves.
Nuclear reactor flow control method and apparatus
Church, John P.
1993-01-01
Method and apparatus for improving coolant flow in a nuclear reactor during accident as well as nominal conditions. The reactor has a plurality of fuel elements in sleeves and a plenum above the fuel and through which the sleeves penetrate. Holes are provided in the sleeve so that coolant from the plenum can enter the sleeve and cool the fuel. The number and size of the holes are varied from sleeve to sleeve with the number and size of holes being greater for sleeves toward the center of the core and less for sleeves toward the periphery of the core. Preferably the holes are all the same diameter and arranged in rows and columns, the rows starting from the bottom of every sleeve and fewer rows in peripheral sleeves and more rows in the central sleeves.
High definition urethral pressure profilometry: Evaluating a novel microtip catheter.
Klünder, Mario; Amend, Bastian; Vaegler, Martin; Kelp, Alexandra; Feuer, Ronny; Sievert, Karl-Dietrich; Stenzl, Arnulf; Sawodny, Oliver; Ederer, Michael
2016-11-01
Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI). SUI is a significant medical, social, and economic problem, affecting about 12.5% of the population. A novel microtip catheter was developed for UPP featuring an inclination sensor and higher angular resolution compared to systems in clinical use today. Therewith, the location of each measured pressure sample can be determined and the spatial pressure distribution inside the urethra reconstructed. In order to assess the performance and plausibility of data from the microtip catheter, we compare it to data from a double balloon air charged system. Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, plotted and compared against data from the air-charged catheter. The microtip catheter delivers results in agreement with previous comparisons of microtip and air-charged systems. It additionally provides a new level of detail in the reconstructed UPPs which may lead to new insights into the sphincter mechanism of minipigs. The ability of air-charged catheters to measure pressure circumferentially is widely considered a main advantage over microtip catheters. However, directional pressure readings can provide additional information on angular fluctuations in the urethral pressure distribution. It is shown that the novel microtip catheter in combination with a signal reconstruction algorithm delivers plausible data. It offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct location within the anatomical location of the pelvic floor. Neurourol. Urodynam. 35:888-894, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
A Raman spectroscopy bio-sensor for tissue discrimination in surgical robotics.
Ashok, Praveen C; Giardini, Mario E; Dholakia, Kishan; Sibbett, Wilson
2014-01-01
We report the development of a fiber-based Raman sensor to be used in tumour margin identification during endoluminal robotic surgery. Although this is a generic platform, the sensor we describe was adapted for the ARAKNES (Array of Robots Augmenting the KiNematics of Endoluminal Surgery) robotic platform. On such a platform, the Raman sensor is intended to identify ambiguous tissue margins during robot-assisted surgeries. To maintain sterility of the probe during surgical intervention, a disposable sleeve was specially designed. A straightforward user-compatible interface was implemented where a supervised multivariate classification algorithm was used to classify different tissue types based on specific Raman fingerprints so that it could be used without prior knowledge of spectroscopic data analysis. The protocol avoids inter-patient variability in data and the sensor system is not restricted for use in the classification of a particular tissue type. Representative tissue classification assessments were performed using this system on excised tissue. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sleeve gastrectomy with anti-reflux procedures
Santoro, Sergio; Lacombe, Arnaldo; de Aquino, Caio Gustavo Gaspar; Malzoni, Carlos Eduardo
2014-01-01
Objective Sleeve gastrectomy is the fastest growing surgical procedure to treat obesity in the world but it may cause or worsen gastroesophageal reflux disease. This article originally aimed to describe the addition of anti-reflux procedures (removal of periesophageal fats pads, hiatoplasty, a small plication and fixation of the gastric remnant in position) to the usual sleeve gastrectomy and to report early and late results. Methods Eighty-eight obese patients that also presented symptoms of gastroesophageal reflux disease were submitted to sleeve gastrectomy with anti-reflux procedures. Fifty of them were also submitted to a transit bipartition. The weight loss of these patients was compared to consecutive 360 patients previously submitted to the usual sleeve gastrectomy and to 1,140 submitted to sleeve gastrectomy + transit bipartition. Gastroesophageal reflux disease symptoms were specifically inquired in all anti-reflux sleeve gastrectomy patients and compared to the results of the same questionnaire applied to 50 sleeve gastrectomy patients and 60 sleeve gastrectomy + transit bipartition patients that also presented preoperative symptoms of gastroesophageal reflux disease. Results In terms of weight loss, excess of body mass index loss percentage after anti-reflux sleeve gastrectomy is not inferior to the usual sleeve gastrectomy and anti-reflux sleeve gastrectomy + transit bipartition is not inferior to sleeve gastrectomy + transit bipartition. Anti-reflux sleeve gastrectomy did not add morbidity but significantly diminished gastroesophageal reflux disease symptoms and the use of proton pump inhibitors to treat this condition. Conclusion The addition of anti-reflux procedures, such as hiatoplasty and cardioplication, to the usual sleeve gastrectomy did not add morbidity neither worsened the weight loss but significantly reduced the occurrence of gastroesophageal reflux disease symptoms as well as the use of proton pump inhibitors. PMID:25295447
Gorscak, Donald A.; Maringo, John J.; Nilsen, Roy J.
1988-01-01
A stuck fuel rod capping sleeve to be used during derodding of spent fuel assemblies if a fuel rod becomes stuck in a partially withdrawn position and, thus, has to be severed. The capping sleeve has an inner sleeve made of a lower work hardening highly ductile material (e.g., Inconel 600) and an outer sleeve made of a moderately ductile material (e.g., 304 stainless steel). The inner sleeve may be made of an epoxy filler. The capping sleeve is placed on a fuel rod which is then severed by using a bolt cutter device. Upon cutting, the capping sleeve deforms in such a manner as to prevent the gross release of radioactive fuel material
Development and evaluation of gas-pressurized elastic sleeves for extravehicular activity.
Tanaka, Kunihiko; Tohnan, Momoka; Abe, Chikara; Iwata, Chihiro; Yamagata, Kenji; Tanaka, Masao; Tanaka, Nobuyuki; Morita, Hironobu
2010-07-01
In space, mobility of the current extravehicular activity space suit is limited due to the pressure differential between the inside and outside of the suit. We have previously demonstrated that an elastic glove increased mobility when compared with a non-elastic glove such as that found in the current suit. Extending this work, we hypothesized that an elastic sleeve would also have more mobility compared to a non-elastic sleeve, but a partially elastic sleeve, consisting of elastic joints sewn to non-elastic parts in low mobility areas, might generate similar mobility to a wholly elastic sleeve. The right arms of 10 volunteers were studied with wholly elastic, partially elastic, and non-elastic sleeves in a chamber pressure of -220 mmHg. Range of motion (ROM) of the wrist and electromyography (EMG) of the flexor carpi radialis muscle and the biceps brachii muscle during wrist and elbow flexion were measured. ROM of the wrist was similar among all the sleeves. However, EMG amplitudes during wrist flexion with both elastic sleeves were significantly smaller than that with the non-elastic sleeve. EMG amplitudes during 90 degrees of elbow flexion were also significantly smaller in both elastic sleeves. However, no significant difference in EMG amplitudes was observed between the two elastic sleeves (0.53 +/- 0.06, 0.56 +/- 0.07, 1.14 +/- 0.10 V for wholly elastic, partially elastic, and non-elastic sleeves, respectively). The mobility of elastic sleeves is better than that of a non-elastic sleeve. Elasticity over the joints is important; however the elasticity of the other parts does not appear to affect mobility.
Harris, William G.
1985-01-01
A heat limiting tubular sleeve extending over only a portion of a tube having a generally uniform outside diameter, the sleeve being open on both ends, having one end thereof larger in diameter than the other end thereof and having a wall thickness which decreases in the same direction as the diameter of the sleeve decreases so that the heat transfer through the sleeve and tube is less adjacent the large diameter end of the sleeve than adjacent the other end thereof.
Xiao, Yong Jie; Chen, Fu Quan; Dong, Yi Zhi
2016-01-01
During driving sleeve of cast-in-place piles by vibratory hammers, soils were squeezed into sleeve and then soil plugging was formed. The physic-mechanical properties of the soil plug have direct influence on the load transmission between the sleeve wall and soil plug. Nevertheless, the researches on this issue are insufficient. In this study, finite element and infinite element coupling model was introduced, through the commercial code ABAQUS, to simulate the full penetration process of the sleeve driven from the ground surface to the desired depth by applying vibratory hammers. The research results indicated that the cyclic shearing action decreases both in soil shear strength and in granular cementation force when the sleeve is driven by vibratory hammers, which leads to a partially plugged mode of the soil plug inside the sleeve. Accordingly, the penetration resistance of sleeve driven by vibratory hammers is the smallest compared to those by other installation methods. When driving the sleeve, the annular soil arches forming in the soil plug at sleeve end induce a significant rise in the internal shaft resistance. Moreover, the influence of vibration frequencies, sleeve diameters, and soil layer properties on the soil plug was investigated in detail, and at the same time improved formulas were brought forward to describe the soil plug resistance inside vibratory driven sleeve.
Unusual Giant Prostatic Urethral Calculus
Bello, A.; Maitama, H. Y.; Mbibu, N. H.; Kalayi, G. D.; Ahmed, A.
2010-01-01
Giant vesico-prostatic urethral calculus is uncommon. Urethral stones rarely form primarily in the urethra, and they are usually associated with urethral strictures, posterior urethral valve or diverticula. We report a case of a 32-year-old man with giant vesico-prostatic (collar-stud) urethral stone presenting with sepsis and bladder outlet obstruction. The clinical presentation, management, and outcome of the giant prostatic urethral calculus are reviewed. PMID:22091328
Summary report, Flexible VSR`s and VSR channel sleeve development programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kempf, F.J.
1963-11-15
(VSR = vertical safety rod.) This report summarizes results of development programs which have evaluated vertical rod channel sleeving materials and provided flexible vertical rods, acceptable for both interim use before rod channel sleeving, and for subsequent use in sleeved channels. B{sub 4}C is the rod material; graphite and Al oxide are among the sleeve materials.
Eisenberg, Michael L; Elliott, Sean P; McAninch, Jack W
2007-12-01
We describe our experience with urethral stents to manage iatrogenic posterior urethral stenosis. We surveyed our retrospective database for patients in whom we placed a urethral stent for posterior urethral stricture disease. We reviewed patient age, comorbidities, indications for stent placement, stricture length, postoperative complications and the repeat stenosis rate. Overall we placed urethral stents in 13 patients, of whom 12 presented with posterior urethral stenosis and 1 presented with anterior and posterior stricture. The etiology of urethral stricture was prostate cancer therapy in 11 of 13 cases and simple prostatectomy in 2. Urethral stenting was chosen instead of urethral reconstruction largely due to prior radiation for prostate cancer and avoidance of the morbidity of surgery. Overall 6 of 13 patients required additional procedures for stricture recurrence, including 5 in previously irradiated patients. Two patients had stents removed due to migration or pain. Genitourinary infections developed in 5 of 13 patients. Eight of 13 patients with a posterior urethral stricture were incontinent, as expected after stent placement. Incontinence was managed by an artificial urinary sphincter in willing patients with 9 of 13 continent. Urethral stents provide reasonable treatment for patients with posterior urethral stenosis when attempting to preserve lower urinary tract function caused by stricture disease after prostate cancer therapy. Prior radiation seems to increase the failure rate. Continence can be maintained after posterior urethral stenting in select patients.
Afatinib in Advanced Refractory Urothelial Cancer
2017-09-28
Distal Urethral Cancer; Proximal Urethral Cancer; Recurrent Bladder Cancer; Recurrent Urethral Cancer; Stage III Bladder Cancer; Stage III Urethral Cancer; Stage IV Bladder Cancer; Stage IV Urethral Cancer; Ureter Cancer
Apparatus and method for measuring the expansion properties of a cement composition
Spangle, Lloyd B.
1983-01-01
An apparatus is disclosed which is useful for measuring the expansion properties of semi-solid materials which expand to a solid phase, upon curing, such as cement compositions. The apparatus includes a sleeve, preferably cylindrical, which has a vertical slit on one side, to allow the sleeve to expand. Mounted on the outside of the sleeve are several sets of pins, consisting of two pins each. The two pins in each set are located on opposite sides of the slit. In the test procedure, the sleeve is filled with wet cement, which is then cured to a solid. As the cement cures it causes the sleeve to expand. The actual expansion of the sleeve represents an expansion factor for the cement. This factor is calculated by measuring the distance across the pins of each set, when the sleeve is empty, and again after the cured cement expands the sleeve.
Pressurizer with a mechanically attached surge nozzle thermal sleeve
Wepfer, Robert M
2014-03-25
A thermal sleeve is mechanically attached to the bore of a surge nozzle of a pressurizer for the primary circuit of a pressurized water reactor steam generating system. The thermal sleeve is attached with a series of keys and slots which maintain the thermal sleeve centered in the nozzle while permitting thermal growth and restricting flow between the sleeve and the interior wall of the nozzle.
Finite element Analysis of Semi-Grouting Sleeve Connection Member Based on ABAQUS
NASA Astrophysics Data System (ADS)
Bao, Longsheng; Fan, Qianyu; Wang, Ling
2018-05-01
This paper use investigates the force transfer mechanism and failure form of semi-grouting sleeve members under axial load, analyze the weak points of structural bearing capacity and verify the reliability of the connection of steel bars through finite element analysis software. The results show that adding the axial load to semi-grouting sleeve forms a 45°oblique compression zone, which help to transfer stress between reinforcement, grouting material and sleeve. Because the maximum stress of sleeve doesn’t reach its tensile resistance and the deformation of the sleeve is located at the junction of the grouting and the threaded section when the stress value of steel bars at each end of the semi-grouting sleeve reach its ultimate tensile strength, we conclude that the semi-grouting sleeve members can meet the construction quality requirements and be used to connect the steel bars at the joints of the assembled structures. It is necessary to avoid breaking down, since the deformation section will accumulate large plastic deformation during the processing of the sleeve.
Urethral calculi with a urethral fistula: a case report and review of the literature.
Zeng, Mingqiang; Zeng, Fanchang; Wang, Zhao; Xue, Ruizhi; Huang, Liang; Xiang, Xuyu; Chen, Zhi; Tang, Zhengyan
2017-09-06
To explore and summarize the reasons why urethral calculi cause a urethral fistula. We retrospectively studied 1 patient in Xiangya hospital and all relevant literature published in English between 1989 and 2015. The patients (including those reported in the literature) were characterized by age, origin, location of calculus, size of calculus, fistulous track, and etiological factors. Most of urethral calculi associated with a urethral fistula were native generated. Urethral calculi can be formed in various locations of the urethra, and the size of the calculus ranged from small (multiple) calculi to giant stones. The fistula external orifice located at the root of the penis was relatively common, and there were various etiological factors, such as urethral strictures, urethral trauma induced by long-term catheterization, lumbar fractures, and congenital anomaly factors. They were managed by the excision of the fistulous tract, retrieval of the urethral stones, and/or debridement and pus drainage operations. Some elements, such as trauma, recurrent urinary tract infections, abscess formation induced by long-term catheterization, and urethral calculus, may be the risk factors for a urethral fistula.
Benett, William J.; Richards, James B.
2003-01-01
A sleeve-type silicon polymerase chain reaction (PCR) chamber or thermocycler having improved thermal performance. The silicon sleeve reaction chamber is improved in thermal performance by etched features therein that reduce thermal mass and increase the surface area of the sleeve for cooling. This improved thermal performance of the thermocycler enables an increase in speed and efficiency of the reaction chamber. The improvement is accomplished by providing grooves in the faces of the sleeve and a series of grooves on the interior surfaces that connect with grooves on the faces of the sleeve. The grooves can be anisotropically etched in the silicon sleeve simultaneously with formation of the chamber.
Benett, William J.; Richards, James B.
2005-05-17
A sleeve-type silicon polymerase chain reaction (PCR) chamber or thermocycler having improved thermal performance. The silicon sleeve reaction chamber is improved in thermal performance by etched features therein that reduce thermal mass and increase the surface area of the sleeve for cooling. This improved thermal performance of the thermocycler enables an increase in speed and efficiency of the reaction chamber. The improvement is accomplished by providing grooves in the faces of the sleeve and a series of grooves on the interior surfaces that connect with grooves on the faces of the sleeve. The grooves can be anisotropically etched in the silicon sleeve simultaneously with formation of the chamber.
Knitted Strain Sensor Textiles of Highly Conductive All-Polymeric Fibers.
Seyedin, Shayan; Razal, Joselito M; Innis, Peter C; Jeiranikhameneh, Ali; Beirne, Stephen; Wallace, Gordon G
2015-09-30
A scaled-up fiber wet-spinning production of electrically conductive and highly stretchable PU/PEDOT:PSS fibers is demonstrated for the first time. The PU/PEDOT:PSS fibers possess the mechanical properties appropriate for knitting various textile structures. The knitted textiles exhibit strain sensing properties that were dependent upon the number of PU/PEDOT:PSS fibers used in knitting. The knitted textiles show sensitivity (as measured by the gauge factor) that increases with the number of PU/PEDOT:PSS fibers deployed. A highly stable sensor response was observed when four PU/PEDOT:PSS fibers were co-knitted with a commercial Spandex yarn. The knitted textile sensor can distinguish different magnitudes of applied strain with cyclically repeatable sensor responses at applied strains of up to 160%. When used in conjunction with a commercial wireless transmitter, the knitted textile responded well to the magnitude of bending deformations, demonstrating potential for remote strain sensing applications. The feasibility of an all-polymeric knitted textile wearable strain sensor was demonstrated in a knee sleeve prototype with application in personal training and rehabilitation following injury.
Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R
2016-12-21
To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients.
Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R
2016-01-01
AIM To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). METHODS VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. RESULTS Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. CONCLUSION Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients. PMID:28058017
Pariser, Joseph J; Pearce, Shane M; Patel, Sanjay G; Bales, Gregory T
2015-07-01
To examine the epidemiology and timing of penile fracture, patterns of urethral evaluation, and risk factors for concomitant urethral injury. The National Inpatient Sample (2003-2011) was used to identify patients with penile fractures. Clinical data included age, race, comorbidity, insurance, hospital factors, timing, hematuria, and urinary symptoms. Rates of formal urethral evaluation (cystoscopy or urethrogram) and urethral injury were calculated. Multivariate logistic regression was used to identify predictors of urethral evaluation and risk factors for urethral injury. A weighted population of 3883 patients with penile fracture was identified. Presentations during weekends (37%) and summers (30%) were overrepresented (both P <.001). Urethral evaluation was performed in 882 patients (23%). Urethral injury was diagnosed in 813 patients (21%) with penile fracture. There was an increased odds of urethral evaluation with hematuria (odds ratio [OR] = 2.99; 95% confidence interval [CI], 1.03-8.73; P = .045) and a decrease for Hispanics (OR = 0.42; 95% CI, 0.22-0.82; P = .011). Older age (32-41 years: OR = 1.84; 95% CI, 1.07-3.16; P = .027; >41 years: OR = 2.25; 95% CI, 1.25-4.05; P = .007), black race (OR = 1.93; 95% CI, 1.12-3.34; P = .018), and hematuria (OR = 17.03; 95% CI, 3.20-90.54; P = .001) were independent risk factors for urethral injury. Penile fractures, which occur disproportionately during summer and weekends, were associated with a 21% risk of urethral injury. Urethral evaluations were performed in a minority of patients. Even in patients with hematuria, 55% of patients underwent formal urethral evaluation. On multivariate analysis of patients with penile fracture, hematuria as well as older age and black race were independently associated with concomitant urethral injury. Copyright © 2015 Elsevier Inc. All rights reserved.
Favazza, C P; Gorny, K R; King, D M; Rossman, P J; Felmlee, J P; Woodrum, D A; Mynderse, L A
2014-08-01
Introduction of urethral warmers to aid cryosurgery in the prostate has significantly reduced the incidence of urethral sloughing; however, the incidence rate still remains as high as 15%. Furthermore, urethral warmers have been associated with an increase of cancer recurrence rates. Here, we report results from our phantom-based investigation to determine the impact of a urethral warmer on temperature distributions around cryoneedles during cryosurgery. Cryoablation treatments were simulated in a tissue mimicking phantom containing a urethral warming catheter. Four different configurations of cryoneedles relative to urethral warming catheter were investigated. For each configuration, the freeze-thaw cycles were repeated with and without the urethral warming system activated. Temperature histories were recorded at various pre-arranged positions relative to the cryoneedles and urethral warming catheter. In all configurations, the urethral warming system was effective at maintaining sub-lethal temperatures at the simulated surface of the urethra. The warmer action, however, was additionally demonstrated to potentially negatively impact treatment lethality in the target zone by elevating minimal temperatures to sub-lethal levels. In all needle configurations, rates of freezing and thawing were not significantly affected by the use of the urethral warmer. The results indicate that the urethral warming system can protect urethral tissue during cryoablation therapy with cryoneedles placed as close as 5mm to the surface of the urethra. Using a urethral warming system and placing multiple cryoneedles within 1cm of each other delivers lethal cooling at least 5mm from the urethral surface while sparing urethral tissue. Copyright © 2014 Elsevier Inc. All rights reserved.
Whitson, Jared M; McAninch, Jack W; Tanagho, Emil A; Metro, Michael J; Rahman, Nadeem U
2008-03-01
Controversy exists regarding continence mechanisms in patients who undergo posterior urethral reconstruction after pelvic fracture. Some evidence suggests that continence after posterior urethroplasty is maintained by the bladder neck or proximal urethral mechanism without a functioning distal mechanism. We studied distal urethral sphincter activity in patients who have undergone posterior urethroplasty for pelvic fracture. A total of 12 patients who had undergone surgical repair of urethral disruption involving the prostatomembranous region underwent videourodynamics with urethral pressure profiles at rest, and during stress and hold maneuvers. Bladder pressure and urethral pressure, including proximal and distal urethral sphincter activity and pressure, were assessed in each patient. All 12 patients had daytime continence of urine postoperatively with a followup after anastomotic urethroplasty of 12 to 242 months (mean 76). Average maximum urethral pressure was 71 cm H2O. Average maximum urethral closure pressure was 61 cm H2O. The average urethral pressure seen during a brief hold maneuver was 111 cm H2O. Average functional sphincteric length was 2.5 cm. Six of the 12 patients had clear evidence of distal urethral sphincter function, as demonstrated by the profile. Continence after anastomotic urethroplasty for posttraumatic urethral strictures is maintained primarily by the proximal bladder neck. However, there is a significant contribution of the rhabdosphincter in many patients.
Babelay, E.F.
1962-02-13
A flexible shaft coupling for operation at speeds in excess of 14,000 rpm is designed which requires no lubrication. A driving sleeve member and a driven sleeve member are placed in concentric spaced relationship. A torque force is transmitted to the driven member from the driving member through a plurality of nylon balls symmetrically disposed between the spaced sleeves. The balls extend into races and recesses within the respective sleeve members. The sleeve members have a suitable clearance therebetween and the balls have a suitable radial clearance during operation of the coupling to provide a relatively loose coupling. These clearances accommodate for both parallel and/or angular misalignments and avoid metal-tometal contact between the sleeve members during operation. Thus, no lubrication is needed, and a minimum of vibrations is transmitted between the sleeve members. (AEC)
Management of severe urethral complications of prostate cancer therapy.
Elliott, Sean P; McAninch, Jack W; Chi, Thomas; Doyle, Sean M; Master, Viraj A
2006-12-01
We present our management of urethral stenosis and rectourinary fistula resulting from prostate cancer therapy. We concentrated on cases refractory to minimally invasive treatment, such as dilation, urethrotomy, and urinary and/or fecal diversion. In our prospectively collected urethral reconstruction database we identified patients who underwent reconstruction of urethral stenosis or rectourinary fistula who also received prior treatment for prostate cancer. We documented demographics, prostate cancer pretreatment characteristics, prostate cancer therapy type, urethral reconstruction type and success. A total of 48 patients met the inclusion criteria, including 16 with rectourinary fistula and 32 with urethral stenosis. Urethral complications followed prior radical prostatectomy, brachytherapy, external beam radiotherapy, cryotherapy, thermal ablation and any combination of these procedures. Stenosis repair was successful in 23 of 32 cases (73%) and it differed little between anterior and posterior urethral stenosis. Repair was accomplished by anastomotic urethroplasty in 19 cases, flap urethroplasty in 2, perineal urethrostomy in 2 and a urethral stent in 9. Prior external beam radiotherapy was a risk factor for urethral reconstruction failure. Fistula repair was successful in 14 of 15 patients (93%), excluding 1 who died postoperatively. The complexity of fistula management was dictated by fistula size and the presence or absence of coincident urethral stenosis. Urethral stenosis or rectourethral fistula following prostate cancer therapy can be managed by urethral reconstruction, such that normal voiding via the urethra is maintained, rather than abandoning the urethral outlet and performing heterotopic diversion. This can be accomplished with an acceptable rate of failure, given the complexity of the cases.
Urethral pull-through operation for the management of pelvic fracture urethral distraction defects.
Yin, Lei; Li, Zhenhua; Kong, Chuize; Yu, Xiuyue; Zhu, Yuyan; Zhang, Yuxi; Jiang, Yuanjun
2011-10-01
To present our institutional experience in the management of pelvic fracture urethral distraction defects with urethral pull-through operation. Seventy-six patients (average age 34.5 years) with posterior urethral strictures caused by pelvic fracture urethral distraction defects underwent urethral pull-through operation at our department from July 1995 to September 2009. The estimated urethral stricture length was 2.0-3.5 cm (mean 2.5). Of these patients, 31 (41%) had undergone failed urethroplasty or urethrotomy after the initial management, and 5 (7%) had urethrorectal fistula. Urethral pull-through operation was performed 4-7 months (mean 4.9) after initial treatment or failed urethral reconstruction. The clinical outcome was considered a failure when any postoperative intervention was needed. Follow-up was 14-74 months (mean 42.5). The overall success rate was 89% (68/76). All treatment failures occurred within the first 6 months postoperatively. Failed repairs were successfully managed with internal urethrotomy in 1 patient, by urethral dilation in 6, and by another urethroplasty in 1. All patients were urinary-continent postoperatively. Of the potent patients, 2 (5%) became impotent after urethroplasty. There was no chordee, penile shortening, or urethral fistula recurrence. Urethral pull-through operation might be a less demanding and less time-consuming procedure. It does not increase the rate of impotence or incontinence and, with a high success rate, might serve as an alternative method for the management of pelvic fracture urethral distraction defects. Copyright © 2011 Elsevier Inc. All rights reserved.
Motorized wellbore fishing tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, L.E.; Schasteen, T.
1989-08-15
This patent describes a fishing tool for retrieving an article located in a wellbore, wherein the fishing tool may be lowered into the wellbore by means connected to one end of the fishing tool. The fishing tool comprising: an elongated tubular body; an inner sleeve member secured to the body and extending axially within the body; a ball key disposed within each of the openings and movable at least partially into the bore in locking registration with a fishing head connected to the article; an outer sleeve member disposed in sleeved relationship around the inner sleeve member and movable axiallymore » between first and second positions with respect to the inner sleeve member. The outer sleeve member being operable to prevent, in the first position, radial outward movement of the ball keys out of the bore. The outer sleeve member including recess means formed thereon such that in the second position of the outer sleeve member the recess means is adjacent to the circumferentially spaced openings to allow limited radial outward movement of the ball keys; and means for axially moving the outer sleeve member between the first and second positions for engaging and releasing the fishing head with respect to the tool.« less
MEMS-Based Flexible Force Sensor for Tri-Axial Catheter Contact Force Measurement
Sheng, Jun; Desai, Jaydev P.
2016-01-01
Atrial fibrillation (AFib) is a significant healthcare problem caused by the uneven and rapid discharge of electrical signals from pulmonary veins (PVs). The technique of radiofrequency (RF) ablation can block these abnormal electrical signals by ablating myocardial sleeves inside PVs. Catheter contact force measurement during RF ablation can reduce the rate of AFib recurrence, since it helps to determine effective contact of the catheter with the tissue, thereby resulting in effective power delivery for ablation. This paper presents the development of a three-dimensional (3D) force sensor to provide the real-time measurement of tri-axial catheter contact force. The 3D force sensor consists of a plastic cubic bead and five flexible force sensors. Each flexible force sensor was made of a PEDOT:PSS strain gauge and a PDMS bump on a flexible PDMS substrate. Calibration results show that the fabricated sensor has a linear response in the force range required for RF ablation. To evaluate its working performance, the fabricated sensor was pressed against gelatin tissue by a micromanipulator and also integrated on a catheter tip to test it within deionized water flow. Both experiments simulated the ventricular environment and proved the validity of applying the 3D force sensor in RF ablation. PMID:28190945
Sinclair, Jonathan; Taylor, Paul John
2017-07-17
Prophylactic knee bracing is extensively utilized in athletic populations, to reduce the high risk from knee injuries, but their role in the attenuation of anterior cruciate ligament (ACL) pathologies is not well understood. The aim of the current investigation was to investigate the effects of a prophylactic knee sleeve on ACL loading parameters linked to the aetiology of injury in recreational athletes. Laboratory. Repeated measures. Thirteen healthy male recreational athletes. Intervention Participants performed run, cut and single leg hop movements under two conditions; prophylactic knee sleeve and no-sleeve. Biomechanical data was captured using an eight-camera 3D motion capture system and a force platform. Peak ACL force, average ACL load rate and instantaneous ACL load rate were quantified using a musculoskeletal modelling approach. The results showed that both average and instantaneous ACL load rates were significantly reduced when wearing the knee sleeve in the hop (sleeve = 612.45/ 1286.39N/kg/s & no-sleeve = 743.91/ 1471.42 N/kg/s) and cut (sleeve = 222.55/ 1058.02 N/kg/s & no-sleeve = 377.38/ 1183.01 N/kg/s) movements. Given the biomechanical association between ACL loading and the aetiology of ACL injuries, it is proposed that athletes may be able to attenuate their risk from injury during cut and hop movements through utilization of a prophylactic knee sleeve.
Blind urethral catheterization in trauma patients suffering from lower urinary tract injuries.
Shlamovitz, Gil Z; McCullough, Lynne
2007-02-01
The goals of our study were to review all cases of urethral and bladder trauma that presented to the University of California, Los Angeles (UCLA) Medical Center between January 1998 and August 2005 and determine (1) the clinical characteristics of patients with urethral and/or bladder injuries as well as the sensitivities of those clinical characteristics; (2) whether or not a blind attempt to insert a urethral catheter was performed; and (3) whether there is any evidence that a blind attempt to insert a urethral catheter worsened the initial urinary tract injury. This is a retrospective chart review. The study cohort comprised 46 patients with a mean age of 30 years, including 36 men (78.2%) and 10 women (21.8%). Bladder tears were found in 33 patients, 10 patients had urethral lacerations, and 3 patients had combined bladder and urethral lacerations. The most sensitive finding for urinary bladder or urethral injury was the presence of gross hematuria in the urethral catheter (100%, 95% confidence interval [CI] 0.63-0.89). Blinded insertion of a urethral catheter was attempted in 30 (90.9%, 95% CI 0.75-0.98) patients who suffered from urinary bladder injury, 6 (50%, 95% CI 0.26-0.87) patients who suffered from urethral injury and 1 (33%, 95% CI 0.0-0.9) patient who suffered from a combined urinary bladder and urethral injuries. We did not find evidence that a blind attempt to insert a urethral catheter worsened the initial urinary injury. Gross hematuria in the urethral catheter was the most sensitive sign for the presence of a urethral or urinary bladder injury in our study cohort, and often the only sign of such an injury. We found no evidence that a blind attempt to insert a urethral catheter in patients suffering from urethral and or urinary bladder injuries worsened the initial injury. Larger studies will be needed to determine the safety of blind urethral catheterization in patients that are suspected to suffer from a lower urological trauma. It is our opinion that the current guidelines should be revised to better reflect the current knowledge, technologies, and clinical practice.
Kureel, Shiv Narain; Gupta, Archika; Singh, Chandra Shekhar; Kumar, Manoj
2013-10-01
To study the anatomic arrangement of the fascial planes and superficial vessels in relationship to the laid-open urethral plate, glans, corpus spongiosum, and corpora cavernosa in the penis of patients with exstrophy or epispadias. Of 6 patients, 4 had classic exstrophy and 2 had incontinent epispadias. These patients had presented beyond adolescence without previous intervention and were selected for the present study. Using a 1.5-T magnetic resonance imaging scanner and compatible 3-in. surface coil, the epispadiac penises were studied using fast spin echo sequences and contrast-enhanced sequences. In 2 patients, angiography of the superficial vessels was also performed using multidetector row helical computed tomography. The imaging findings were also verified during the subsequent reconstructive surgery. A clear demarcation of the skin, dartos fascia, Buck's fascia, corpora cavernosa, corpus spongiosum, and the intraglanular planes were seen with the course of the blood vessels. The penile dartos received axial pattern vessels from the external pudendal vessels, with collateral branches from the dorsal penile artery as transverse branches at the shaft of the penis and preputial branches at the coronal sulcus. Buck's fascia sleeved the corpora cavernosa, enveloped the neurovascular bundle, and fused with the corpus spongiosum without crossing the midline. Intraglanular extension of Buck's fascia separated the intraglanular vascular arcade from the tip of the corpora. Parallel to the ventral midline, axial pattern vessels to the skin-dartos complex are present, with an additional supply to the prepuce from the terminal penile arteries. These findings can be used for designing the skin coverage. The subfascial plane between the tip of the corpora and the intraglanular vascular arcade and the plane of cleavage between the cavernosa-spongiosum interface can be used for efficient corporal urethral separation. Copyright © 2013 Elsevier Inc. All rights reserved.
de Graaf, Petra; van der Linde, E Martine; Rosier, Peter F W M; Izeta, Ander; Sievert, Karl-Dietrich; Bosch, J L H Ruud; de Kort, Laetitia M O
2017-06-01
Tissue-engineered (TE) urethra is desirable in men with urethral disease (stricture or hypospadias) and shortage of local tissue. Although ideally a TE graft would contain urethral epithelium cells, currently, bladder epithelium (urothelium) is widely used, but morphologically different. Understanding the differences and similarities of urothelium and urethral epithelium could help design a protocol for in vitro generation of urethral epithelium to be used in TE grafts for the urethra. To understand the development toward urethral epithelium or urothelium to improve TE of the urethra. A literature search was done following PRISMA guidelines. Articles describing urethral epithelium and bladder urothelium development in laboratory animals and humans were selected. Twenty-nine studies on development of urethral epithelium and 29 studies on development of urothelium were included. Both tissue linings derive from endoderm and although adult urothelium and urethral epithelium are characterized by different gene expression profiles, the signaling pathways underlying their development are similar, including Shh, BMP, Wnt, and FGF. The progenitor of the urothelium and the urethral epithelium is the early fetal urogenital sinus (UGS). The urethral plate and the urothelium are both formed from the p63+ cells of the UGS. Keratin 20 and uroplakins are exclusively expressed in urothelium, not in the urethral epithelium. Further research has to be done on unique markers for the urethral epithelium. This review has summarized the current knowledge about embryonic development of urothelium versus urethral epithelium and especially focuses on the influencing factors that are potentially specific for the eventual morphological differences of both cell linings, to be a basis for developmental or tissue engineering of urethral tissue.
Mechanism Research on Melting Loss of Coppery Tuyere Small Sleeve in Blast Furnace
NASA Astrophysics Data System (ADS)
Chai, Yi-Fan; Zhang, Jian-Liang; Ning, Xiao-Jun; Wei, Guang-Yun; Chen, Yu-Ting
2016-01-01
The tuyere small sleeve in blast furnace works under poor conditions. The abnormal damage of it will severely affect the performance of the blast furnace, thus it should be replaced during the damping down period. So it is of great significance that we study and reduce the burnout of tuyere small sleeve. Melting loss is one case of its burnout. This paper studied the reasons of tuyere small sleeve's melting loss, through computational simulation and microscopic analysis of the melting section. The research shows that the temperature of coppery tuyere small sleeve is well distributed when there is no limescale in the lumen, and the temperature increases with the thickness of limescale. In addition, the interruption of circulating water does great harm to the tuyere small sleeve. The melting loss of tuyere small sleeve is caused by iron-slag erosion, with the occurrence of the melt metallurgical bonding and diffusion metallurgical combination.
Comparison of stiffness and interface pressure during rest and exercise among various arm sleeves.
Hirai, M; Niimi, K; Iwata, H; Sugimoto, I; Ishibashi, H; Ota, T; Nakamura, H
2010-08-01
To compare the interface pressure during rest and exercise among various kinds of arm sleeves. The interface pressure underneath nine different arm sleeves was measured during 10 maximal opening and closing movements of fingers using a pressure transducer (Air Pack Type Analyser) in 16 healthy volunteers. Furthermore, in order to evaluate the characteristics of each arm sleeve, the extensibility, stiffness and thickness were determined in vitro by several apparatuses. There was a significant correlation between stiffness and extensibility. The stiffness was significantly correlated with the pressure difference between muscle contraction and relaxation during exercise. The higher the value of stiffness, the greater the pressure amplitude during exercise. Short-stretch arm sleeves characterized with a high level stiffness, including thick round- and flat-knitted arm sleeves, are more beneficial for the augmentation of muscle pumping than long-stretch arm sleeves, in the same way as short-stretch bandages or stockings applied to the leg.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lane, W.L.; Lewis, D.L.
1987-04-07
A rockbolt is described for installation in a bore in the roof of an underground excavation to support the roof, the rockbolt comprising: a sleeve insertable into the bore and having an upper and a lower end; at least one port in the sleeve near the upper end; means inside the sleeve near the upper end for engaging a device for supplying hardenable binder material inserted into the sleeve, the engaging means having at least one passage therein communicating with the port to allow binder material to pass from the device through the engaging means and out the port, tomore » encase the sleeve in binder material; means for engaging the sleeve, near the lower end, to the roof face; means for engaging the sleeve near the upper end to the rock surrounding the bore and means for tensioning the rockbolt to compress the rock between the upper and lower ends.« less
Wang, Wen-Min; Qiu, Wei-Feng; Qian, Chong
2010-07-01
To explore the feasibility of urethroplasty with transection of the urethral orifice and preservation and lengthening of the urethral plate in the treatment of hypospadias. Forty-eight patients with hypospadias (18 of the coronal type, 21 the penile type, 8 the penoscrotal type and 1 the perineal type) underwent urethroplasty with transection of the urethral orifice and preservation and lengthening of the urethral plate. The surgical effects were observed by following up the patients for 3-27 months. One-stage surgical success was achieved in 44 of the cases, with satisfactory functional and cosmetic results but no complications. Two cases developed urinary fistula and another 2 urethral stricture, but all cured by the second surgery. Urethroplasty with transection of the urethral orifice and preservation and lengthening of the urethral plate is a simple, safe and effective surgical procedure for the treatment of hypospadias.
Swell Sleeves for Testing Explosive Devices
NASA Technical Reports Server (NTRS)
Hinkel, Todd J.; Dean, Richard J.; Hohmann, Carl W.; Hacker, Scott C.; Harrington, Douglas W.; Bacak, James W.
2003-01-01
A method of testing explosive and pyrotechnic devices involves exploding the devices inside swell sleeves. Swell sleeves have been used previously for measuring forces. In the present method, they are used to obtain quantitative indications of the energy released in explosions of the devices under test. A swell sleeve is basically a thick-walled, hollow metal cylinder threaded at one end to accept a threaded surface on a device to be tested (see Figure 1). Once the device has been tightly threaded in place in the swell sleeve, the device-and-swell-sleeve assembly is placed in a test fixture, then the device is detonated. After the explosion, the assembly is removed from the test fixture and placed in a coordinate-measuring machine for measurement of the diameter of the swell sleeve as a function of axial position. For each axial position, the original diameter of the sleeve is subtracted from the diameter of the sleeve as swollen by the explosion to obtain the diametral swelling as a function of axial position (see Figure 2). The amount of swelling is taken as a measure of the energy released in the explosion. The amount of swelling can be compared to a standard amount of swelling to determine whether the pyrotechnic device functioned as specified.
Fretting and Corrosion Damage in Taper Adapter Sleeves for Ceramic Heads: A Retrieval Study.
MacDonald, Daniel W; Chen, Antonia F; Lee, Gwo-Chin; Klein, Gregg R; Mont, Michael A; Kurtz, Steven M; Cates, Harold E; Kraay, Matthew J; Rimnac, Clare M
2017-09-01
During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In vitro testing suggests that corrosion is not a concern in sleeved ceramic heads; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties. Thirty-seven sleeved ceramic heads were collected during revision. The femoral heads and sleeves were implanted 0.0-3.3 years. The implants were revised predominantly for instability, infection, and loosening. Fifty percent of the retrievals were implanted during a primary surgery. Fretting corrosion was assessed using the Goldberg-Higgs semiquantitative scoring system. Mild-to-moderate fretting corrosion scores (score = 2-3) were observed in 92% of internal tapers, 19% of external tapers, and 78% of the stems. Severe fretting corrosion was observed in 1 stem trunnion that was previously retained during revision surgery and none of the retrieved sleeves. There was no difference in corrosion damage of sleeves used in primary or revision surgery. The fretting corrosion scores in this study were predominantly mild and lower than reported fretting scores of cobalt-chrome heads in metal-on-polyethylene bearings. Although intended for use in revisions, we found that the short-term in vivo corrosion behavior of the sleeves was similar in both primary and revision surgery applications. From an in vivo corrosion perspective, sleeves are a reasonable solution for restoring the stem taper during revision surgery. Copyright © 2017. Published by Elsevier Inc.
Shafik, A; Shafik, A A; Shafik, I; el-Sibai, O
2005-01-01
The functional activity of the urethral sphincters during cavernosus muscles' contraction at coitus has been poorly addressed in the literature. We investigated the hypothesis that cavernosus muscles' contraction affects reflex contraction of the urethral sphincters to guard against semen reflux into the urinary bladder or urine leakage from the bladder during orgasm and ejaculation. The electromyographic (EMG) response of the external (EUS) and internal (IUS) urethral sphincters to ischio- (ICM) and bulbo- (BCM) cavernosus muscle stimulation was studied in 15 healthy volunteers (9 men, 6 women, age 39.3 +/- 8.2 SD years). An electrode was applied to each of ICM and BCM (stimulating electrodes) and the 2 urethral sphincters (recording electrodes). The test was repeated after individual anesthetization of the urethral sphincters and the 2 cavernosus muscles, and after using saline instead of lidocaine. Upon stimulation of each of the 2 cavernosus muscles, the EUS and IUS recorded increased EMG activity. Repeated cavernosus muscles' stimulation evoked the urethral sphincteric response without fatigue. The urethral sphincters did not respond to stimulation of the anesthetized cavernosus muscles nor did the anesthetized urethral sphincters respond to cavernosus muscle stimulation. Saline infiltration instead of lidocaine did not affect the urethral sphincteric response to cavernosal muscle stimulation. Results were reproducible. Cavernosus muscles' contraction is suggested to effect EUS and IUS contraction. This action seems to be reflex and mediated through the 'cavernoso-urethral reflex.' Urethral sphincters contraction upon cavernosus muscles contraction during sexual intercourse presumably prevents urine leak from the urinary bladder to urethra, prevents retrograde ejaculation, and propels ejaculate from the posterior to the penile urethra. The cavernoso-urethral reflex can act a diagnostic tool in the investigations of patients with ejaculatory disorders.
A Wideband Corner-Reflector Antenna for 240 to 400 MHz.
1983-09-19
8217 .; ,:,:. .-.:.,.;.. - -... - .- . -.. .-- v...- ..... .-. .-.- 1,.:..- FIGURES 1. Corner Reflector with Open-Sleeve Dipole Feed ............ ...... 7 2...Open-Sleeve Dipole Feed for Corner Reflector, 240-400 MHz........ 8 3. Closeup Photo of Open-Sleeve Dpole ..................... ...... 8 4. VSWR of...4-ft Corner Reflector, Open-Sleeve Dipole Feed .......... 9 5. Gain of Corner Reflector............ .............. . ....... 9 6. Measured E- and H
System and method for manufacture of airfoil components
Moors, Thomas Michael
2016-11-29
Embodiments of the present disclosure relate generally to systems and methods for manufacturing an airfoil component. The system can include: a geometrical mold; an elongated flexible sleeve having a closed-off interior and positioned within the geometrical mold, wherein the elongated flexible sleeve is further positioned to have a desired geometry; an infusing channel in fluid communication with the closed-off interior of the elongated flexible sleeve and configured to communicate a resinous material thereto; a vacuum channel in fluid communication with the closed-off interior of the elongated flexible sleeve and configured to vacuum seal the closed-off interior of the elongated flexible sleeve; and a glass fiber layer positioned within the closed-off interior of the elongated flexible sleeve.
Hong, Young-Kwon; Choi, Kyung-Hwa; Lee, Young-Tae; Lee, Seung-Ryeol
2017-05-01
Internal urethrotomy (IU) in patients with urethral contracture following perineal repair of pelvic fracture urethral injuries (PRPFUI) is troublesome. We evaluated the clinical factors affecting the surgical outcome of IU for urethral contracture after PRPFUI. We retrospectively reviewed the records of 35 patients who underwent IU for urethral contracture after PRPFUI between March 2004 and June 2013. Ages of patients ranged from 18 to 50, and their follow-up duration was more than 1year after IU. The urethral contracture was confirmed by retrograde urethrogram or cysto-urethroscopy. Success was defined as greater than 15mL/s of peak urinary flow rate at 1year after IU without any clinical evidence of urethral contracture. Success rates were investigated according to the number of IU. Age, body mass index, urethral defect length before PRPFUI, time interval between the original urethral injury and the PRPFUI or between a previous operation and the PRPFUI, time interval between the PRPFUI and the urethral contracture, number of PRPFUI performed, and the type of urethral lengthening procedure were compared between patients with and without success according to the number of IU. Among the 35 patients, the overall success rate of IU was 37% (13/35) during the mean follow-up period of 53 months (range: 17-148 months). There were 8 and 5 patients with success in first and second IU, respectively. However, there was no success after third IU. Urethral defect length before PRPFUI was significantly shorter in patients with success who underwent first and second IU (p<0.05). There were significant differences of success between patients with and without previous repeated failures of PRPFUI in first and second IU (p<0.05). Short urethral defect length and no previous surgical failures before PRPFUI are good prognostic factors for IU following PRPFUI. Only one or two IUs will be helpful in patients with urethral contracture following PRPFUI. Copyright © 2017 Elsevier Ltd. All rights reserved.
Okuda, Hidenobu; Tei, Norihide; Shimizu, Kiyonori; Imazu, Tetsuo; Yoshimura, Kazuhiro; Kiyohara, Hisakazu
2008-07-01
Perforation of the bladder related to long-term indwelling urethral catheter is a rare and serious complication. A 85-year-old man with an indwelling urethral catheter presented severe hematuria, abdominal pain with rebound tenderness and muscular tension over the suprapubic area after the exchange of the urethral catheter. Computed tomography and cystogram revealed experitoneal bladder perforation due to indwelling catheter. Three weeks after the indwelling urethral catheter had been placed, the perforation was closed. In most cases, laparotomy and suprapubic cystostomy are performed. We describe the case of experitoneal bladder perforation successfully treated by urethral drainage.
Gelman, Joel; Wisenbaugh, Eric S.
2015-01-01
Pelvic fracture urethral injuries are typically partial and more often complete disruptions of the most proximal bulbar and distal membranous urethra. Emergency management includes suprapubic tube placement. Subsequent primary realignment to place a urethral catheter remains a controversial topic, but what is not controversial is that when there is the development of a stricture (which is usually obliterative with a distraction defect) after suprapubic tube placement or urethral catheter removal, the standard of care is delayed urethral reconstruction with excision and primary anastomosis. This paper reviews the management of patients who suffer pelvic fracture urethral injuries and the techniques of preoperative urethral imaging and subsequent posterior urethroplasty. PMID:26691883
[Transurethral thulium laser urethrotomy for urethral stricture].
Liu, Chun-Lai; Zhang, Xi-Ling; Liu, Yi-Li; Wang, Ping
2011-09-01
To evaluate the effect of endourethrotomy with thulium laser as a minimally invasive treatment for urethral stricture. We treated 36 cases of urethral stricture or atresia by endourethrotomy with thulium laser, restored the urethral continuity by vaporization excision of the scar tissue, and observed the clinical effects and complications. The mean operation time was 35 min, ranging from 10 to 90 min. Smooth urination was achieved after 2-6 weeks of catheter indwelling, with no urinary incontinence. The patients were followed up for 4-24 (mean 12) months, during which 27 did not need any reintervention, 5 developed urinary thinning but cured by urethral dilation, 3 received another laser urethrotomy for previous negligence of timely urethral dilation, and the other 1 underwent open urethroplasty. Thulium laser urethrotomy is a safe and effective minimally invasive option for short urethral stricture, which is also suitable for severe urethral stricture and urethral atresia. Its short-term outcome is satisfactory, but its long-term effect remains to be further observed.
... urinary retention with • bladder drainage • urethral dilation • urethral stents • prostate medications • surgery The type and length of ... patient will receive sedation and regional anesthesia. Urethral Stents Another treatment for urethral stricture involves inserting an ...
Current management of urethral stricture disease
Smith, Thomas G.
2016-01-01
Introduction: Broadly defined, urethral strictures are narrowing of the urethral lumen that is surrounded by corpus spongiosum, i.e., urethral meatus through the bulbar urethra. Urethral stenosis is narrowing of the posterior urethra, i.e., membranous urethra through bladder neck/prostate junction, which is not enveloped by corpus spongiosum. The disease has significant quality of life ramifications because many times younger patients are affected by this compared to many other urological diseases. Methods: A review of the scientific literature concerning urethral stricture, stenosis, treatment, and outcomes was performed using Medline and PubMed (U.S. National Library of Medicine and the National Institutes of Health). Abstracts from scientific meetings were included in this review. Results: There is level 3 evidence regarding the etiology and epidemiology of urethral strictures, stenoses, and pelvic fracture urethral injuries. Outcomes data from literature regarding intervention for urethral stricture are largely limited to level 3 evidence and expert opinion. There is a single level 1 study comparing urethral dilation and direct vision internal urethrotomy. Urethroplasty outcomes data are limited to level 3 case series. Conclusions: Progress is being made toward consistent terminology, and nomenclature which will, in turn, help to standardize treatment within the field of urology. Treatment for urethral stricture and stenosis remains inconsistent between reconstructive and nonreconstructive urologists due to varying treatment algorithms and approaches to disease management. Tissue engineering appears to be future for reconstructive urethral surgery with reports demonstrating feasibility in the use of different tissue substitutes and grafts. PMID:26941491
Primary urethral reconstruction: the cost minimized approach to the bulbous urethral stricture.
Rourke, Keith F; Jordan, Gerald H
2005-04-01
Treatment for urethral stricture disease often requires a choice between readily available direct vision internal urethrotomy (DVIU) and highly efficacious but more technically complex open urethral reconstruction. Using the short segment bulbous urethral stricture as a model, we determined which strategy is less costly. The costs of DVIU and open urethral reconstruction with stricture excision and primary anastomosis for a 2 cm bulbous urethral stricture were compared using a cost minimization decision analysis model. Clinical probability estimates for the DVIU treatment arm were the risk of bleeding, urinary tract infection and the risk of stricture recurrence. Estimates for the primary urethral reconstruction strategy were the risk of wound complications, complications of exaggerated lithotomy and the risk of treatment failure. Direct third party payer costs were determined in 2002 United States dollars. The model predicted that treatment with DVIU was more costly (17,747 dollars per patient) than immediate open urethral reconstruction (16,444 dollars per patient). This yielded an incremental cost savings of $1,304 per patient, favoring urethral reconstruction. Sensitivity analysis revealed that primary treatment with urethroplasty was economically advantageous within the range of clinically relevant events. Treatment with DVIU became more favorable when the long-term risk of stricture recurrence after DVIU was less than 60%. Treatment for short segment bulbous urethral strictures with primary reconstruction is less costly than treatment with DVIU. From a fiscal standpoint urethral reconstruction should be considered over DVIU in the majority of clinical circumstances.
Urethral calculi in young-adult Nigerian males: a case series.
Gali, B M; Ali, N; Agbese, G O; Garba, I I; Musa, K
2011-01-01
Urethral calculi are rare and usually encountered in males with urethral pathology. To present our experience managing urethral calculi in a resource limited centre and review the literature. We did a chart review of management of patients with urethral calculi between January and April 2009, at Federal Medical Centre (FMC) Azare, Nigeria. We also reviewed the literature on this rare condition. Four young adult male Nigerians between the ages of 17 and 27 years presented with varying degrees of urethral pain and palpable calculi in the anterior urethra. Two presented with acute retention of urine, but none had haematuria. The calculi were radio-opaque, located in the anterior urethra with no associated urethral pathology. Three were solitary and one multiple. The composition of the urethral calculi was a mixture of calcium oxalate calcium carbonate, magnesium phosphate, one has additional cystine but none had struvite or uric acid. Their sizes ranged between 1cm ×1.5cm and 1.5cm × 5.5cm. External urethrotomy was the method of treatment. Urethral calculi are rare in our setting, with no clear identifiable aetiological factors which suggests urinary schistosomiasisbeing associsted. The occurrence of urethral calculi appears to have a relationship with childhood urinary schistosomasis.
Two-Dimensional Automatic Measurement for Nozzle Flow Distribution Using Improved Ultrasonic Sensor
Zhai, Changyuan; Zhao, Chunjiang; Wang, Xiu; Wang, Ning; Zou, Wei; Li, Wei
2015-01-01
Spray deposition and distribution are affected by many factors, one of which is nozzle flow distribution. A two-dimensional automatic measurement system, which consisted of a conveying unit, a system control unit, an ultrasonic sensor, and a deposition collecting dish, was designed and developed. The system could precisely move an ultrasonic sensor above a pesticide deposition collecting dish to measure the nozzle flow distribution. A sensor sleeve with a PVC tube was designed for the ultrasonic sensor to limit its beam angle in order to measure the liquid level in the small troughs. System performance tests were conducted to verify the designed functions and measurement accuracy. A commercial spray nozzle was also used to measure its flow distribution. The test results showed that the relative error on volume measurement was less than 7.27% when the liquid volume was 2 mL in trough, while the error was less than 4.52% when the liquid volume was 4 mL or more. The developed system was also used to evaluate the flow distribution of a commercial nozzle. It was able to provide the shape and the spraying width of the flow distribution accurately. PMID:26501288
Remotely Adjustable Hydraulic Pump
NASA Technical Reports Server (NTRS)
Kouns, H. H.; Gardner, L. D.
1987-01-01
Outlet pressure adjusted to match varying loads. Electrohydraulic servo has positioned sleeve in leftmost position, adjusting outlet pressure to maximum value. Sleeve in equilibrium position, with control land covering control port. For lowest pressure setting, sleeve shifted toward right by increased pressure on sleeve shoulder from servovalve. Pump used in aircraft and robots, where hydraulic actuators repeatedly turned on and off, changing pump load frequently and over wide range.
Coring device with a improved core sleeve and anti-gripping collar with a collective core catcher
DOE Office of Scientific and Technical Information (OSTI.GOV)
Story, A.L.; Filshtinsky, M.
1986-01-28
This patent describes an improved coring apparatus used in combination with a coring bit and drill string. This device consists of: an outer driving structure adapted to be connected at one end to the coring bit for cutting a core in a borehole, and at the other end to the lower end of the drill string in telescoping and co-rotatable manner therewith; an inner barrel disposed within the outer driving structure and including a lower end portion adjacent to the bit; first means supporting the inner barrel in spaced relationship to the outer driving structure while permitting rotation of themore » driving structure with respect to the inner barrel; a woven metal mesh sleeve mounted in surrounding relation on at least a portion of the exterior surface of the inner barrel; second means, connected to a free end of the sleeve opposite the leading portion of the sleeve, for maintaining the portion of the sleeve which surrounds the inner barrel in compression and to maintain an inside diameter greater than the outside diameter of the inner barrel of the portion of the sleeve surrounding the inner barrel while the portion of the sleeve positioned inside the inner barrel being in tension to grip and compress a core received within the sleeve and having an outside diameter less than the inside diameter of the inner barrel when in tension, wherein the second means is also for engaging the core when the means is drawn into the inner barrel, and third means positioned within the inner barrel and connected to the leading portion of the sleeve to draw the sleeve within the inner barrel and to apply tension to the portion of the sleeve within the barrel to encase and grip the core as it is cut.« less
de Vrieze, Nynke Hesselina Neeltje; van Rooijen, Martijn; Speksnijder, Arjen Gerard Cornelis Lambertus; de Vries, Henry John C
2013-08-01
Urethral lymphogranuloma venereum (LGV) is not screened routinely. We found that in 341 men having sex with men with anorectal LGV, 7 (2.1%) had concurrent urethral LGV. Among 59 partners, 4 (6.8%) had urethral LGV infections. Urethral LGV is common, probably key in transmission, and missed in current routine LGV screening algorithms.
Bronchovascular versus bronchial sleeve resection for central lung tumors.
Lausberg, Henning F; Graeter, Thomas P; Tscholl, Dietmar; Wendler, Olaf; Schäfers, Hans-Joachim
2005-04-01
Pneumonectomy has traditionally been the treatment of choice for central lung tumors. Bronchial sleeve resections are increasingly considered as a reasonable alternative. For tumor involvement of both central airways and pulmonary artery, bronchovascular sleeve resections are possible, but considered to be technically demanding and associated with a higher perioperative risk. In addition, their role as adequate oncologic treatment for lung cancer is unclear. We have compared the early and long-term results of bronchovascular sleeve resection with those of bronchial sleeve resection and pneumonectomy. We retrospectively analyzed all patients who underwent bronchial sleeve resection (group I, n = 104), bronchovascular sleeve resection (group II, n = 67), and pneumonectomy (group III, n = 63) for central lung cancer in our institution. The groups were comparable regarding demographics and tumor, node, and metastasis (TNM) stage. Early mortality was 1.9% in group I, 1.5% in group II, and 6.3% in group III (p = 0.19). The rate of bronchial complications was 0.96% in group I, 0% in group II, and 7.9% in group III (p = 0.006). Five-year survival was 46.1% in group I, 42.9% in group II, and 30.4% in group III (p = 0.16). Freedom from local recurrence of disease (5 years) was 83.8% in group I, 84.2% in group II, and 88.7% in group III (p = 0.56). Bronchovascular sleeve resections are as safe as bronchial sleeve resections for the treatment of central lung cancer. Both procedures have comparable early and long-term results, which are similar to those of pneumonectomy. It appears reasonable to apply bronchovascular sleeve resections more liberally.
Seo, Ill Young; Lee, Jea Whan; Park, Seung Chol; Rim, Joung Sik
2012-12-01
Although endoscopic realignment has been accepted as a standard treatment for urethral injuries, the long-term follow-up data on this procedure are not sufficient. We report the long-term outcome of primary endoscopic realignment in bulbous urethral injuries. Patients with bulbous urethral injuries were treated by primary endoscopic realignment between 1991 and 2005. The operative procedure included suprapubic cystostomy and transurethral catheterization using a guide wire, within 72 hours of injury. The study population included 51 patients with a minimum follow-up duration of 5 years. The most common causes of the injuries were straddle injury from falling down (74.5%), and pelvic bone fracture (7.8%). Gross hematuria was the most common complaint (92.2%). Twenty-three patients (45.1%) had complete urethral injuries. The mean time to operation after the injury was 38.8±43.2 hours. The mean operation time and mean indwelling time of a urethral Foley catheter were 55.5±37.6 minutes and 22.0±11.9 days, respectively. Twenty out of 51 patients (39.2%) were diagnosed with urethral stricture in 89.1±36.6 months after surgery. A multivariate analysis revealed that young age and operation time were independent risk factors for strictures as a complication of urethral realignment (hazard ratio [HR], 6.554, P=0.032; HR, 6.206, P=0.035). Urethral stricture commonly developed as a postoperative complication of primary endoscopic urethral realignment for bulbous urethral injury, especially in young age and long operation time.
Pazopanib in Treating Patients With Metastatic Urothelial Cancer
2014-05-22
Distal Urethral Cancer; Proximal Urethral Cancer; Recurrent Bladder Cancer; Recurrent Transitional Cell Cancer of the Renal Pelvis and Ureter; Recurrent Urethral Cancer; Stage IV Bladder Cancer; Transitional Cell Carcinoma of the Bladder; Urethral Cancer Associated With Invasive Bladder Cancer
Urethral injury in the multiple-injured patient.
Cass, A S
1984-10-01
A total of 74 patients with urethral injury due to external trauma consisted of 48 posterior urethral injuries (25 complete rupture, 23 partial rupture) and 26 anterior urethral injuries (two complete rupture, 16 partial rupture, and eight contusion). The diagnosis was made by retrograde urethrography. All 48 patients with posterior urethral injury had associated injuries, including a fractured pelvis in 46, and a mortality rate of 33%. Only seven of the 26 patients with anterior urethral injury had associated injuries and a mortality rate of 14%. The management of posterior urethral injury is changing from primary realignment of the ruptured urethra to suprapubic cystostomy alone and followed later by urethral surgery for the resulting stricture. The impotence rate is significantly lower with management with suprapubic cystostomy alone. However, the type of pelvic fracture, the urethral injury itself disrupting neurovascular structures, and the surgical dissection (initial primary realignment or delayed urethroplasty) must be investigated before it can be determined whether the impotence associated with pelvic trauma is caused by the injury itself or by the surgical dissection undertaken to reconstruct the urethra.
Installation and assembly device and method of using
Kolsun, George J.
1997-01-01
An installation and assembly device for aligning a first member such as a pump impeller with a second member such as an inlet nozzle of an impeller pump. The installation and assembly device includes a sleeve slideable within the inlet nozzle and a vertical positioning assembly which has a contact member that is extendable out away from the sleeve so as to vertically position the sleeve on a shoulder of the inlet nozzle and to present an upper contact surface spaced a certain distance from the shoulder to provide the desired vertical spacing with respect to the impeller contacting the upper contact surface. The vertical positioning assembly is retractable so as to allow for removal of the sleeve through the nozzle when installation and assembly are completed. The alignment device also includes a radial alignment assembly supported by the sleeve and adjustable to an expanded state for contacting and spacing the interior surface of the impeller a certain distance from the sleeve and hence a certain distance from the inlet nozzle. The radial alignment device being adjustable from a retracted removal state to an expanded state and also being adjustable to fine tune the spacing of the impeller from the sleeve. The radial alignment device also preferably includes members that can be used to releasably secure the sleeve to the impeller.
Ballout, Rami A; Maatouk, Ismael
2018-01-01
This is the case of a young man presenting with urethritis despite a negative infectious work-up. Careful history taking elucidated a strong correlation between symptom onset and a recent dose escalation of isotretinoin for treatment of his refractory cystic acne. The urethral symptoms quickly resolved with dose reduction, suggesting urethritis as a rare adverse reaction of isotretinoin.
Kajbafzadeh, Abdol-Mohammad; Rasouli, Mohammad Reza; Dianat, SeyedSaeid; Nezami, Behtash G; Mahboubi, Amir Hassan; Sina, Alireza
2010-11-01
The aim of the study was to evaluate the efficacy and safety of urethral hydrodistension for management of urethral hypoplasia in prune belly syndrome (PBS). During a 10-year period, 7 infants with PBS and urethral hypoplasia presented either with open urachus or surgically created urinary diversion referred to our hospital. Five milliliters of normal saline was pushed via a 22-gauge plastic angiocatheter into the urethra with simultaneous finger pressure on the perineum to occlude the proximal urethra that was repeated with higher volumes of the solution (up to 20 mL). The procedure was continued until a 6F or 8F feeding tube catheter confirmed the urethral patency. Hydrodistension was repeated in 3-month intervals till complete patency was confirmed by imaging. Median age of the infants was 6 (1-8) months. All urethral hydrodistension were successful after 1 to 3 sessions. Follow-up imaging studies showed significant improvement in all patients except one. Natural and surgically created urinary diversions were closed in 6 infants. The hydrodistension create an equal and constant pressure into the urethral wall without any urethral damage. This technique can be considered along with the other available methods for management of urethral hypoplasia in selected cases of PBS. Copyright © 2010 Elsevier Inc. All rights reserved.
Combination drilling and skiving tool
Stone, William J.
1989-01-01
A combination drilling and skiving tool including a longitudinally extending hollow skiving sleeve slidably and concentrically mounted on a right-handed twist drill. Dogs or pawls provided on the internal periphery of the skiving sleeve engage with the helical grooves of the drill. During a clockwise rotation of the tool, the drill moves downwardly and the sleeve translates upwardly, so that the drill performs a drilling operation on a workpiece. On the other hand, the drill moves upwardly and the sleeve translates downwardly, when the tool is rotated in a counter-clockwise direction, and the sleeve performs a skiving operation. The drilling and skiving operations are separate, independent and exclusive of each other.
NASA Technical Reports Server (NTRS)
Giandomenico, A.; Dame, J. M.; Behimer, H. (Inventor)
1978-01-01
A wrench is described that is usable where limited access normally requires an open-end wrench, but which has substantially the high-torque capacity and small radial clearance characteristics of a closed-end wrench. The wrench includes a sleeve forming a nut-engageable socket with a gap in its side, and an adaptor forming a socket with a gap in its side, the adaptor closely surrounding the sleeve and extending across the gap in the sleeve. The sleeve and adaptor have surfaces that become fully engaged when a wrench handle is applied to the adaptor to turn it so as to tighten a nut engaged by the sleeve.
Insert sleeve prevents tube soldering contamination
NASA Technical Reports Server (NTRS)
Stein, J.
1966-01-01
Teflon sleeve insert prevents contamination of internal tube surfaces by solder compound during soldering operations that connect and seal the tube ends. The sleeve insert is pressed into the mating tube ends with a slight interference fit.
External combustor for gas turbine engine
Santanam, Chandran B.; Thomas, William H.; DeJulio, Emil R.
1991-01-01
An external combustor for a gas turbine engine has a cyclonic combustion chamber into which combustible gas with entrained solids is introduced through an inlet port in a primary spiral swirl. A metal draft sleeve for conducting a hot gas discharge stream from the cyclonic combustion chamber is mounted on a circular end wall of the latter adjacent the combustible gas inlet. The draft sleeve is mounted concentrically in a cylindrical passage and cooperates with the passage in defining an annulus around the draft sleeve which is open to the cyclonic combustion chamber and which is connected to a source of secondary air. Secondary air issues from the annulus into the cyclonic combustion chamber at a velocity of three to five times the velocity of the combustible gas at the inlet port. The secondary air defines a hollow cylindrical extension of the draft sleeve and persists in the cyclonic combustion chamber a distance of about three to five times the diameter of the draft sleeve. The hollow cylindrical extension shields the drive sleeve from the inlet port to prevent discharge of combustible gas through the draft sleeve.
ELECTROMAGNETIC APPARATUS FOR MOVING A ROD
Young, J.N.
1957-08-20
An electromagnetic device for moving an object in a linear path by increments is described. The device is specifically adapted for moving a neutron absorbing control rod into and out of the core of a reactor and consists essentially of an extension member made of magnetic material connected to one end of the control rod and mechanically flexible to grip the walls of a sleeve member when flexed, a magnetic sleeve member coaxial with and slidable between limit stops along the flexible extension, electromagnetic coils substantially centrally located with respect to the flexible extension to flex the extension member into gripping engagement with the sleeve member when ener gized, moving electromagnets at each end of the sleeve to attract the sleeve when energized, and a second gripping electromagnet positioned along the flexible extension at a distance from the previously mentioned electromagnets for gripping the extension member when energized. In use, the second gripping electromagnet is deenergized, the first gripping electromagnet is energized to fix the extension member in the sleeve, and one of the moving electromagnets is energized to attract the sleeve member toward it, thereby moving the control rod.
Modeling and testing of a knitted-sleeve fluidic artificial muscle
NASA Astrophysics Data System (ADS)
Ball, Erick J.; Meller, Michael A.; Chipka, Jordan B.; Garcia, Ephrahim
2016-11-01
The knitted-sleeve fluidic muscle is similar in design to a traditional McKibben muscle, with a separate bladder and sleeve. However, in place of a braided sleeve, it uses a tubular-knit sleeve made from a thin strand of flexible but inextensible yarn. When the bladder is pressurized, the sleeve expands by letting the loops of fiber slide past each other, changing the dimensions of the rectangular cells in the stitch pattern. Ideally, the internal volume of the sleeve would reach a maximum when its length has contracted by 2/3 from its maximum length, and although this is not reachable in practice, preliminary tests show that free contraction greater than 50% is achievable. The motion relies on using a fiber with a low coefficient of friction in order to reduce hysteresis to an acceptable level. In addition to increased stroke length, potential advantages of this technique include slower force drop-off during the stroke, more useable energy in certain applications, and greater similarity to the force-length relationship of skeletal muscle. Its main limitation is its potentially greater effect from friction compared to other fluidic muscle designs.
Stimulated pressure profile at rest: a noninvasive method for assessing urethral sphincter function.
Meyer, S; Kuntzer, T; De Grandi, P; Bachelard, O; Schreyer, A
1998-10-01
To validate a method for assessing urethral sphincter muscle function by recording rises in intraurethral pressure during repetitive pudendal nerve stimulations. A supine urethral pressure profile at rest was performed on 12 stress-continent and 28 stress-incontinent patients during repetitive pudendal nerve stimulations applied near the ischial spine, and the intraurethral pressure increases were calculated for each third of the urethral functional length. No significant difference in intraurethral pressure increases was seen between continent and stress-incontinent women. On the various regression curves, the intraurethral pressure increases showed a significant correlation with maximal urethral closure pressure values at rest and at stress (r = 0.36 to 0.54) and with the patient's age (r = 0.46), but not with pudendal nerve conduction times to the urethral sphincter on either side (r = 0.14 and 0.19). This method (1) measures intraurethral pressure increases that correlate well with the anatomic location of the urethral sphincter muscle, (2) shows there is no significant difference between them in continent and stress-incontinent patients, except in patients with a low-pressure urethra, and (3) demonstrates that they correlate well with the maximal urethral closure pressure and the patient's age, but not with pudendal motor latencies to the urethral sphincter. This method gives us a mapping of the urethral sphincter activity, explaining why some patients with a low-pressure urethra have less urinary loss than others with the same urethral closure pressure.
Urethral Cancer—Patient Version
Urethral cancer is rare and is more common in men than in women. Urethral cancer can metastasize (spread) quickly to tissues around the urethra and has often spread to nearby lymph nodes by the time it is diagnosed. Start here to find information on urethral cancer treatment.
Urethral Cancer—Health Professional Version
Urethral cancer is a rare cancer. There are three types of urethral cancer. Squamous cell carcinoma is the most common type. Transitional cell carcinoma of the urethra, and adenocarcinoma in the glands around the urethra are less common. Find evidence-based information on urethral cancer treatment.
Buccal mucosa urethroplasty for adult urethral strictures
Zimmerman, W. Britt; Santucci, Richard A.
2011-01-01
Urethral strictures are difficult to manage. Some treatment modalities for urethral strictures are fraught with high patient morbidity and stricture recurrence rates; however, an extremely useful tool in the armamentarium of the Reconstructive Urologist is buccal mucosal urethroplasty. We like buccal mucosa grafts because of its excellent short and long-term results, low post-operative complication rate, and relative ease of use. We utilize it for most our bulbar urethral stricture repairs and some pendulous urethral stricture repairs, usually in conjunction with a first-stage Johanson repair. In this report, we discuss multiple surgical techniques for repair of urethral stricture disease. Diagnosis, evaluation of candidacy, surgical techniques, post-operative care, and complications are included. The goal is to raise awareness of buccal mucosa grafting for the management urethral stricture disease. PMID:22022061
Ong, J J; Fethers, K; Howden, B P; Fairley, C K; Chow, E P F; Williamson, D A; Petalotis, I; Aung, E; Kanhutu, K; De Petra, V; Chen, M Y
2017-08-01
Guidelines regarding whether men who have sex with men (MSM) without symptoms of urethritis should be screened for urethral gonorrhoea differ between countries. We examined the rate of asymptomatic urethral gonorrhoea in MSM using sensitive nucleic acid amplification testing. This study was conducted on consecutive MSM attending the Melbourne Sexual Health Centre between July 2015 and May 2016 for sexually transmitted infections screening. Gonorrhoea testing with the Aptima Combo 2 (AC2) assay was performed on all urine specimens obtained from MSM, whether symptoms of urethritis were present or not. Men were classified as having: typical discharge if they reported symptoms suggesting purulent discharge; other symptoms if they reported other symptoms of urethritis; and no symptoms if they reported no urethral symptoms. During the study period, there were 7941 clinic visits by 5947 individual MSM with 7090 urine specimens obtained from 5497 individual MSM tested with the AC2 assay. Urethral gonorrhoea was detected in 242 urine specimens from 228 individual MSM. The majority (189/242, 78%, 95% CI 73-83) reported typical discharge, 27/242 (11%, 95% CI 8-16) reported other urethral symptoms, and 26/242 (11%, 95% CI 7-15) reported no symptoms on the day of presentation and testing. Among men with urethral gonorrhoea, the proportions with concurrent pharyngeal or rectal gonorrhoea were 32% (134/210) and 64% (74/235), respectively. The mean interval between last reported sexual contact and onset of typical urethral discharge, where present, was 3.9 days. The findings from our study lend support to guidelines that recommend screening asymptomatic MSM for urethral gonorrhoea. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
2014-10-10
Adenocarcinoma of the Bladder; Distal Urethral Cancer; Metastatic Transitional Cell Cancer of the Renal Pelvis and Ureter; Proximal Urethral Cancer; Recurrent Bladder Cancer; Recurrent Transitional Cell Cancer of the Renal Pelvis and Ureter; Recurrent Urethral Cancer; Squamous Cell Carcinoma of the Bladder; Stage III Bladder Cancer; Stage III Urethral Cancer; Stage IV Bladder Cancer; Transitional Cell Carcinoma of the Bladder; Urethral Cancer Associated With Invasive Bladder Cancer
Godsil, E.C.; Robinson, E.Y.
1963-07-16
A variable-throw cam comprising inner and outer eccentric sleeves which are adjustably locked together is described. The cam throw is varied by unlocking the inner and outer sleeves, rotating the outer sleeve relative to the inner one until the desired throw is obtained, and locking the sleeves together again. The cam is useful in applications wherein a continuously-variable throw is required, e.g., ram-and-die pressing operations, cyclic fatigue testing of materials, etc. (AEC)
Regeneratively cooled transition duct with transversely buffered impingement nozzles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrison, Jay A; Lee, Ching-Pang; Crawford, Michael E
2015-04-21
A cooling arrangement (56) having: a duct (30) configured to receive hot gases (16) from a combustor; and a flow sleeve (50) surrounding the duct and defining a cooling plenum (52) there between, wherein the flow sleeve is configured to form impingement cooling jets (70) emanating from dimples (82) in the flow sleeve effective to predominately cool the duct in an impingement cooling zone (60), and wherein the flow sleeve defines a convection cooling zone (64) effective to cool the duct solely via a cross-flow (76), the cross-flow comprising cooling fluid (72) exhausting from the impingement cooling zone. In themore » impingement cooling zone an undimpled portion (84) of the flow sleeve tapers away from the duct as the undimpled portion nears the convection cooling zone. The flow sleeve is configured to effect a greater velocity of the cross-flow in the convection cooling zone than in the impingement cooling zone.« less
NASA Technical Reports Server (NTRS)
Burgess, Kevin (Inventor); Yakos, David (Inventor); Walthall, Bryan (Inventor)
2011-01-01
A stemless ball valve comprising two flanges and a ball with a channel, two axis pins and two travel pins. One end of each axis and travel pin is fixedly attached to the ball, and the other end of each axis pin is lodged into a notch in the first or second flange such that the axis pin is allowed to rotate in the notch. The guide sleeve comprises two channels, and one end of each travel pin is situated within one of the two channels in the guide sleeve. An outer magnetic cartridge causes the inner magnetic cartridge and guide sleeve to rotate, and when the guide sleeve rotates, the travel pins move up and down within the channels in the guide sleeve. The movement of the travel pins within the channels in the guide sleeve causes the ball to rotate, thereby opening and closing the ball valve.
Safety System for Controlling Fluid Flow into a Suction Line
NASA Technical Reports Server (NTRS)
England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)
2015-01-01
A safety system includes a sleeve fitted within a pool's suction line at the inlet thereof. An open end of the sleeve is approximately aligned with the suction line's inlet. The sleeve terminates with a plate that resides within the suction line. The plate has holes formed therethrough. A housing defining a plurality of distinct channels is fitted in the sleeve so that the distinct channels lie within the sleeve. Each of the distinct channels has a first opening on one end thereof and a second opening on another end thereof. The second openings reside in the sleeve. Each of the distinct channels is at least approximately three feet in length. The first openings are in fluid communication with the water in the pool, and are distributed around a periphery of an area of the housing that prevents coverage of all the first openings when a human interacts therewith.
Aşci, R; Sarikaya, S; Büyükalpelli, R; Saylik, A; Yilmaz, A F; Yildiz, S
1999-08-01
The aim of this study is to evaluate the effects of the different immediate treatment modalities on the sexual and voiding functions in pelvic fracture urethral injuries. The records of 38 male patients with traumatic posterior urethral injuries were reviewed, 18 of whom were treated by initial suprapubic cystostomy and delayed repair (Group 1), and 20 by primary urethral realignment (Group 2). Types of pelvic fractures and urethral injuries were classified according to surgical and radiological findings. Long-term voiding functions were determined by the patient questionnaire, residual urine and uroflow. Sexual functions were also determined by the patient questionnaire and a penile duplex ultrasound study. Mean follow-ups of Groups 1 and 2 were 37 and 39 months, respectively. Membranous urethral disruption extending to the urogenital diaphragm was the most frequent urethral injury (type 3), with incidences of 66.7% and 77.7%, respectively. There were no statistically significant differences in mean age, incidence of pelvic fracture types and urethral injury types between groups (p > 0.05). After the immediate treatments, 16.7% and 55% of the patients regained normal urination, and stricture developed in 83.3% and 45% of the patients, respectively. In 44.4% of the patients in Group 1 and 10% in Group 2, urethral strictures required open urethroplasty (p < 0.05). Erectile impotence before urethroplasty in 17.6% and 20%, anejaculation after urethroplasty in 17.6% and 15% and incontinence in 5.6% and 10% of the patients were found in Groups 1 and 2, respectively (p > 0.05). However, 88.8% and 90% of patients eventually achieved normal urination with complete continence. Sexual and voiding dysfunction after pelvic fracture posterior urethral injury seem to be the result of the injury itself, not of the immediate treatment modalities. In urethral disruption injuries, primary urethral realignment seems more favourable than suprapubic cystostomy and delayed repair.
Wearing long sleeves while prepping a patient in the operating room decreases airborne contaminants.
Markel, Troy A; Gormley, Thomas; Greeley, Damon; Ostojic, John; Wagner, Jennifer
2018-04-01
The use of long sleeves by nonscrubbed personnel in the operating room has been called into question. We hypothesized that wearing long sleeves and gloves, compared with having bare arms without gloves, while applying the skin preparation solution would decrease particulate and microbial contamination. A mock patient skin prep was performed in 3 different operating rooms. A long-sleeved gown and gloves, or bare arms, were used to perform the procedure. Particle counters were used to assess airborne particulate contamination, and active and passive microbial assessment was achieved through air samplers and settle plate analysis. Data were compared with Student's t-test or Mann-Whitney U, and P < .05 was considered to be significant. Operating room B demonstrated decreased 5.0- µm particle sizes with the use of sleeves, while operating rooms A and C showed decreased total microbes only with the use of sleeves. Despite there being no difference in the average number of total microbes for all operating rooms assessed, the use of sleeves specifically appeared to decrease the shed of Micrococcus. The use of long sleeves and gloves while applying the skin preparation solution decreased particulate and microbial shedding in several of the operating rooms tested. Although long sleeves may not be necessary for all operating room personnel, they may decrease airborne contamination while the skin prep is applied, which may lead to decreased surgical site infections. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Long-term effect of urethral dilatation and internal urethrotomy for urethral strictures.
Veeratterapillay, Rajan; Pickard, Rob S
2012-11-01
Urethral dilatation and direct visual internal urethrotomy (DVIU) are widely used minimally invasive options to manage men with urethral strictures. Advances in open urethroplasty with better long-term cure rates have fuelled the continuing debate as to which treatment is best for primary and recurrent urethral strictures. We reviewed recent literature to identify contemporary practice of urethral dilatation and DVIU and the long-term outcome of these procedures. Systematic literature search for the period January 2010 to December 2011 showed that urethral dilatation and DVIU remain frequently used treatment options as confirmed by surveys of urologists in the USA and the Netherlands. Multiple reports of laser DVIU confirm the safety of this approach but long-term data were lacking. Stricture free rates from urethra dilatation and DVIU vary from 10 to 90% at 12 months, although adjunctive intermittent self-dilatation can reduce time to recurrence. Although quality-of-life benefit appears good in the short term, repeated procedures may harm sexual function in the long-term. Urethral dilatation and DVIU remain widely used in urethral stricture management but high-level comparative evidence of benefit and harms against urethroplasty in the short and long-term is still lacking.
Use of an Absorbable Urethral Stent for the Management of a Urethral Stricture in a Stallion.
Trela, Jan M; Dechant, Julie E; Culp, William T; Whitcomb, Mary B; Palm, Carrie A; Nieto, Jorge E
2016-11-01
To describe the successful management of a urethral stricture with an absorbable stent in a stallion. Clinical report. Stallion with a urethral stricture. A 12-year-old Thoroughbred breeding stallion was evaluated for acute onset of colic. Uroperitoneum because of presumptive urinary bladder rupture, with urethral obstruction by a urethrolith, was diagnosed. The uroperitoneum was treated conservatively. The urethrolith was removed through a perineal urethrotomy. Approximately 15 weeks after urethrolith removal, the stallion presented with a urethral stricture. The stricture was unsuccessfully treated with an indwelling urinary catheter and 4 attempts at balloon dilation. Eight weeks after diagnosis of stricture, an absorbable polydioxanone (20 mm × 80 mm) urethral stent was implanted under percutaneous, ultrasound guidance. Urethroscopy was performed at 70, 155, and 230 days after stent placement and the endoscope passed through the affected site without complication. Urethroscopy at 155 days showed the stent had been reabsorbed. Follow-up 20 months after stent placement reports the stallion was able to void a normal urine stream. Absorbable urethral stent placement was a feasible treatment for urethral stricture in this stallion. © Copyright 2016 by The American College of Veterinary Surgeons.
Pelvic-fracture urethral injury in children
Hagedorn, Judith C.; Voelzke, Bryan B.
2015-01-01
Objective To review paediatric posterior urethral injuries and the current potential management options; because urethral injury due to pelvic fracture in children is rare and has a low incidence, the management of this type of trauma and its complications remains controversial. Methods We reviewed previous reports identified by searching the PubMed Medline electronic database for clinically relevant articles published in the past 25 years. The search was limited to the keywords ‘pediatric’, ‘pelvic fracture’, ‘urethral injury’, ‘stricture’, ‘trauma’ and ‘reconstruction’. Results Most paediatric urethral injuries are a result of pelvic fractures after high-impact blunt trauma. After the diagnosis, immediate bladder drainage via a suprapubic cystotomy, or urethral realignment, are the initial management options, except for a possible immediate primary repair in girls. The common complications of pelvic fracture-associated urethral injury include urethral stricture formation, incontinence and erectile dysfunction. Excellent results can be achieved with delayed urethroplasty for pelvic fracture-associated urethral injuries. Conclusion Traumatic injury to the paediatric urethra is rare and calls for an immediate diagnosis and management. These devastating injuries have a high complication rate and therefore a close follow-up is warranted to assure adequate delayed repair by a reconstructive urologist. PMID:26019977
21 CFR 876.4590 - Interlocking urethral sound.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Interlocking urethral sound. 876.4590 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4590 Interlocking urethral sound. (a) Identification. An interlocking urethral sound is a device that consists of two metal sounds...
21 CFR 876.4590 - Interlocking urethral sound.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Interlocking urethral sound. 876.4590 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4590 Interlocking urethral sound. (a) Identification. An interlocking urethral sound is a device that consists of two metal sounds...
21 CFR 876.4590 - Interlocking urethral sound.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Interlocking urethral sound. 876.4590 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4590 Interlocking urethral sound. (a) Identification. An interlocking urethral sound is a device that consists of two metal sounds...
21 CFR 876.4590 - Interlocking urethral sound.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Interlocking urethral sound. 876.4590 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4590 Interlocking urethral sound. (a) Identification. An interlocking urethral sound is a device that consists of two metal sounds...
21 CFR 876.4590 - Interlocking urethral sound.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Interlocking urethral sound. 876.4590 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4590 Interlocking urethral sound. (a) Identification. An interlocking urethral sound is a device that consists of two metal sounds...
Apparatus for a compact adjustable passive compliant mechanism
Salisbury, Curt Michael
2015-03-17
Various technologies described herein pertain to an adjustable compliance apparatus. The adjustable compliance apparatus includes a shaft, a sleeve element, and a torsion spring. The sleeve element includes a bore there through, where the shaft is positioned through the bore of the sleeve element. Further, the torsion spring includes a plurality of coils, where the shaft is positioned through the plurality of coils. Moreover, the sleeve element is slidable in an axial direction along the shaft between the torsion spring and the shaft. Accordingly, compliance of the adjustable compliance apparatus is adjustable based on a number of the plurality of coils in contact with the sleeve element as positioned along the shaft within the torsion spring.
[Effect of Radii barrier sleeves on cure depth of composite resin].
Wang, Binping; DU, Yongxiu
2009-01-01
To explore the effect of Radii barrier sleeves on the cure depth of composite resin. Cylinder mold was prepared, and the resin was filled strictly into the mold. The surface was flattened and then cured with plastic engraver's knife.The depth of composite resin which was cured by QHL75TM with or without Radii barrier sleeves was compared. The cure depth of composite resin which were cured by QHL75TM with or without Radii barrier sleeves of photo-curing machine was 4.38 mm and 4.27 mm respectively,with no statistical difference. The cure depth of composite resin is not influenced by Radii barrier sleeves under the same light condition.
Ro, Kyung-Han; Park, Jong-Hoon; Kim, Myo-Jong; Lee, Dae-Hee
2014-03-01
Sleeve fractures are generally restricted to children or adolescents, and usually occur at the lower patella pole. Here we report on a superior pole sleeve fracture in an adult that occurred following forceful passive physiotherapy after cast immobilization. To our knowledge, this is the first report of a superior pole sleeve fracture in an otherwise healthy adult. The case highlighted that a diagnosis of a superior patella pole sleeve fracture in an adult can easily be missed because it is a rare injury, and hence is unlikely to be suspected by physicians. Copyright © 2013 Elsevier B.V. All rights reserved.
Left lower lobe sleeve lobectomy for lung cancer using the Da Vinci surgical system.
Zhao, Yandong; Jiao, Wenjie; Ren, Xiaoyang; Zhang, Liangdong; Qiu, Tong; Fu, Bo; Wang, Lei
2016-04-12
Despite the robotic surgery is widely applied, sleeve lobectomy for lung cancer using the Da Vinci surgical system is still less performed. We described a sleeve lobectomy for adenocarcinoma located at the left lower lobe using the Da Vinci surgical system. A case of 57-year old female referred to our hospital. Computed tomography scan showed an occupation located at the left lower lobe and adenocarcinoma project from the lobe bronchus was diagnosed by bronchoscope examination. A sleeve lobectomy was performed using the Da Vinci surgical system and the postoperative recovery was uneventful. Robotic thoracic surgery is feasible to perform sleeve lobectomy inspite of inadequate experience.
Jendrzejczyk, Joseph A.
1982-01-01
An electrical fluid force transducer for measuring the magnitude and direction of fluid forces caused by lateral fluid flow, includes a movable sleeve which is deflectable in response to the movement of fluid, and a rod fixed to the sleeve to translate forces applied to the sleeve to strain gauges attached to the rod, the strain gauges being connected in a bridge circuit arrangement enabling generation of a signal output indicative of the magnitude and direction of the force applied to the sleeve.
NASA Astrophysics Data System (ADS)
Liu, Yong Jun; Li, Chao; Zhou, When Jun
2018-06-01
This paper presents some numerical simulation results of tensile properties of reinforcing bars spliced by grout-filled coupling sleeves under fire conditions to identify the effect of load ratio on fire resistance time of spliced reinforcing bars, which provide a useful base for predicting structural behaviors of pre-cast reinforced concrete buildings in fires. A spliced rebar system investigated in this paper consists of two equal-diameter steel reinforcing bars with 25mm diameter and a straight coupling sleeve with 50mm outer and 45mm inner diameters. As a result, the thickness of grout between steel bars and sleeves are 20mm. Firstly, the temperature distributions in steel bars connected by grout- filled coupling sleeves exposed to ISO 834 standard fire were calculated utilizing finite element analysis software ANSYS. Secondly, the stress changes in heated steel bars connected by grout-filled coupling sleeves under different constant tensile loads were calculated step by step until the rebar system failed due to fire. Thus, the fire resistant time of rebar spliced by grout-filled coupling sleeves under different axial tensile loads can be determined, further, the relationship between fire resistance time and axial tensile loads ratio can could be obtained. Finally, the fire resistant times versus axial tensile load ratios curve of grout-filled splice sleeve rebars exposed to ISO 834 standard fire is presented.
Madhok, B M; Carr, W R J; McCormack, C; Boyle, M; Jennings, N; Schroeder, N; Balupuri, S; Small, P K
2016-08-01
Laparoscopic sleeve gastrectomy is a safe and effective bariatric operation, but postoperative reflux symptoms can sometimes necessitate revisional surgery. Roux-en-Y gastric bypass is the preferred operation in morbidly obese patients with gastro-oesophageal reflux disease. In 2011, we introduced preoperative endoscopy to assess for hiatus hernia or evidence of oesophagitis in conjunction with an assessment of gastro-oesophageal reflux symptoms for all patients undergoing bariatric surgery with a view to avoid sleeve gastrectomy for these patients. A prospectively maintained database was used to identify patients who underwent sleeve gastrectomy before and after we changed the unit policy. The need for revisional surgery in patients with troublesome gastro-oesophageal reflux disease was examined. Prior to 2011, 130 patients underwent sleeve gastrectomy, and 11 (8.5%) of them required conversion to Roux-en-Y gastric bypass for symptomatic reflux disease. Following the policy change, 284 patients underwent sleeve gastrectomy, and to date, only five (1.8%) have required revisional surgery (p = 0.001). Baseline demographics were comparable between the groups, and average follow-up period was 47 and 33 months, respectively, for each group. Preoperative endoscopy and a detailed clinical history regarding gastro-oesophageal reflux symptoms may improve patient selection for sleeve gastrectomy. Avoiding sleeve gastrectomy in patients with reflux disease and/or hiatus hernia may reduce the incidence of revisional surgery. © 2016 World Obesity.
[Causes and management for male urethral stricture].
Chen, Caifang; Zeng, Mingqiang; Xue, Ruizhi; Wang, Guilin; Gao, Zhiyong; Yuan, Wuxiong; Tang, Zhengyan
2018-05-28
To explore the etiology of male urethral stricture, analyze the therapeutic strategies of urethral stricture, and summarize the complicated cases. Methods: The data of 183 patients with urethral stricture were retrospectively analyzed, including etiology, obstruction site, stricture length, therapeutic strategy, and related complications. Results: The mean age was 49.7 years, the average course was 64.7 months, and the constituent ratio of 51 to 65 years old patients was 38.8% (71/183). The traumatic injury of patients accounted for 52.4% (96/183), in which the pelvic fracture accounted for 35.5% (65/183) and the straddle injury accounted for 16.9% (31/183). There were 54 cases of iatrogenic injury (29.5%). The posterior urethral stricture accounted for 45.9% (84/183), followed by the anterior urethral stricture (44.8%, 82/183) and the stenosis (6.6%, 12/183). A total of 99 patients (54.1%) received the end to end anastomosis, and 40 (21.9%) were treated with intracavitary surgery, such as endoscopic holmium laser, cold knife incision, endoscopic electroknife scar removal, balloon dilation, and urethral dilation. In the patients over 65-years old, the urethral stricture rate was 14.8% and the complication rate (70.4%) for transurethral resection of the prostate (TURP) was significantly higher than that of all samples (P<0.01). Conclusion: Both the etiology of male urethral stricture and the treatment strategy have changed and the incidence of traumatic and iatrogenic urethral stricture has increased in recent 3 years. The main treatment of urethral stricture has been transformed from endoscopic surgery into urethroplasty.
Deng, Tuo; Liao, Banghua; Luo, Deyi; Liu, Bing; Wang, Kunjie; Liu, Jiaming; Jin, Tao
2015-01-01
Objective: Therapy for anterior combined with posterior urethral stricture is difficult and controversial. This study aims to introduce a standard process for managing anterior combined with posterior urethral stricture. Patients and methods: 19 patients with anterior combined with posterior urethral stricture were treated following our standard process. Average (range) age was 52 (21-72) years old. In this standard process, anterior urethral stricture should be treated first. Endoscopic surgery is applied for anterior urethra stricture as a priority as long as obliteration does not occur, and operation for posterior urethral stricture can be conducted in the same stage. Otherwise, an open reconstructive urethroplasty for anterior urethral is needed; while in this condition, the unobliterated posterior urethra can also be treated with endoscopic surgery in the same stage; however, if posterior urethra obliteration exists, then open reconstructive urethroplasty for posterior urethral stricture should be applied 2-3 months later. Results: The median (range) follow-up time was 25.8 (3-56) months. All 19 patients were normal in urethrography after 1 month of the surgery. 4 patients (21.1%) recurred urethral stricture during follow-up, and the locations of recurred stricture were bulbomembranous urethra (2 cases), bulbar urethra (1 case) and bladder neck (1 case). 3 of them restored to health through urethral dilation, yet 1 underwent a second operation. 2 patients (10.5%) complaint of dripping urination. No one had painful erection, stress urinary incontinence or other complications. Conclusions: The management for anterior combined with posterior urethral stricture following our standard process is effective and safe. PMID:26064293
Peterli, Ralph; Wölnerhanssen, Bettina Karin; Peters, Thomas; Vetter, Diana; Kröll, Dino; Borbély, Yves; Schultes, Bernd; Beglinger, Christoph; Drewe, Jürgen; Schiesser, Marc; Nett, Philipp; Bueter, Marco
2018-01-16
Sleeve gastrectomy is increasingly used in the treatment of morbid obesity, but its long-term outcome vs the standard Roux-en-Y gastric bypass procedure is unknown. To determine whether there are differences between sleeve gastrectomy and Roux-en-Y gastric bypass in terms of weight loss, changes in comorbidities, increase in quality of life, and adverse events. The Swiss Multicenter Bypass or Sleeve Study (SM-BOSS), a 2-group randomized trial, was conducted from January 2007 until November 2011 (last follow-up in March 2017). Of 3971 morbidly obese patients evaluated for bariatric surgery at 4 Swiss bariatric centers, 217 patients were enrolled and randomly assigned to sleeve gastrectomy or Roux-en-Y gastric bypass with a 5-year follow-up period. Patients were randomly assigned to undergo laparoscopic sleeve gastrectomy (n = 107) or laparoscopic Roux-en-Y gastric bypass (n = 110). The primary end point was weight loss, expressed as percentage excess body mass index (BMI) loss. Exploratory end points were changes in comorbidities and adverse events. Among the 217 patients (mean age, 45.5 years; 72% women; mean BMI, 43.9) 205 (94.5%) completed the trial. Excess BMI loss was not significantly different at 5 years: for sleeve gastrectomy, 61.1%, vs Roux-en-Y gastric bypass, 68.3% (absolute difference, -7.18%; 95% CI, -14.30% to -0.06%; P = .22 after adjustment for multiple comparisons). Gastric reflux remission was observed more frequently after Roux-en-Y gastric bypass (60.4%) than after sleeve gastrectomy (25.0%). Gastric reflux worsened (more symptoms or increase in therapy) more often after sleeve gastrectomy (31.8%) than after Roux-en-Y gastric bypass (6.3%). The number of patients with reoperations or interventions was 16/101 (15.8%) after sleeve gastrectomy and 23/104 (22.1%) after Roux-en-Y gastric bypass. Among patients with morbid obesity, there was no significant difference in excess BMI loss between laparoscopic sleeve gastrectomy and laparoscopic Roux-en-Y gastric bypass at 5 years of follow-up after surgery. clinicaltrials.gov Identifier: NCT00356213.
Improved design and durability of aluminum die casting horizontal shot sleeves
NASA Astrophysics Data System (ADS)
Birceanu, Sebastian
The design and performance of shot sleeves is critical in meeting the engineering requirements of aluminum die cast parts. Improvement in shot sleeve materials have a major impact on dimensional stability, reproducibility and quality of the product. This investigation was undertaken in order to improve the life of aluminum die casting horizontal shot sleeves. Preliminary pin tests were run to evaluate the soldering, wash-out and thermal fatigue behavior of commercially available materials and coatings. An experimental rig was designed and constructed for shot sleeve configuration evaluation. Fabrication and testing of experimental shot sleeves was based upon preliminary results and manufacturing costs. Three shot sleeve designs and materials were compared to a reference nitrided H13 sleeve. Nitrided H13 is the preferred material for aluminum die casting shot sleeves because of wear resistance, strength and relative good soldering and wash-out resistance. The study was directed towards damage evaluation on the area under the pouring hole. This area is the most susceptible to damage because of high temperatures and impingement of molten aluminum. The results of this study showed that tungsten and molybdenum had the least amount of soldering and wash-out damage, and the best thermal fatigue resistance. Low solubility in molten aluminum and stability of intermetallic layers are main factors that determine the soldering and wash-out behavior. Thermal conductivity and thermal expansion coefficient directly influence thermal fatigue behavior. TiAlN nanolayered coating was chosen as the material with the best damage resistance among several commercial PVD coatings, because of relatively large thickness and simple deposition conditions. The results show that molybdenum thermal sprayed coating provided the best protection against damage under the pouring hole. Improved bonding is however required for life extension of the coating. TiAlN PVD coating applied on H13 nitrided substrate performed very well as long as the coating was maintained. Nitrided H13 sleeve showed extensive damage that occurred as early as 200 cycles. The nitrided layer only slowed down the diffusion process and dissolution took place at a higher rate as soon as the layer wore off. Stellite 6 sleeve also showed considerable wear under the action of molten aluminum.
2018-06-11
Bladder Urothelial Carcinoma; Distal Urethral Carcinoma; Infiltrating Bladder Urothelial Carcinoma Associated With Urethral Carcinoma; Metastatic Urothelial Carcinoma of the Renal Pelvis and Ureter; Proximal Urethral Carcinoma; Recurrent Bladder Carcinoma; Recurrent Prostate Carcinoma; Recurrent Urethral Carcinoma; Recurrent Urothelial Carcinoma of the Renal Pelvis and Ureter; Regional Urothelial Carcinoma of the Renal Pelvis and Ureter; Stage IV Bladder Cancer AJCC v7; Stage IV Prostate Cancer AJCC v7; Stage IV Urethral Cancer AJCC v7; Ureter Carcinoma
Gillitzer, R; Hampel, C; Pahernik, S; Melchior, S W; Thüroff, J W
2006-09-01
We present a case of post-traumatic posterior urethral stricture and localized prostate cancer, which could be treated successfully with simultaneous radical perineal prostatectomy and membranous urethral stricture excision. After 6 months follow-up, the patient is continent with no evidence of stricture recurrence. Post-traumatic posterior urethral strictures can be managed surgically through a perineal approach with high success rates. Prostate surgery after pelvic fracture with posterior urethral distraction defects does not necessarily lead to stress urinary incontinence.
Biomechanical and functional efficacy of knee sleeves: A literature review.
Mohd Sharif, Nahdatul Aishah; Goh, Siew-Li; Usman, Juliana; Wan Safwani, Wan Kamarul Zaman
2017-11-01
Knee sleeves are widely used for the symptomatic relief and subjective improvements of knee problems. To date, however, their biomechanical effects have not been well understood. To determine whether knee sleeves can significantly improve the biomechanical variables for knee problems. Systematic literature search was conducted on four online databases - PubMed, Web of Science, ScienceDirect and Springer Link - to find peer-reviewed and relevant scientific papers on knee sleeves published from January 2005 to January 2015. Study quality was assessed using the Structured Effectiveness Quality Evaluation Scale (SEQES). Twenty studies on knee sleeves usage identified from the search were included in the review because of their heterogeneous scope of coverage. Twelve studies found significant improvement in gait parameters (3) and functional parameters (9), while eight studies did not find any significant effects of knee sleeves usage. Most improvements were observed in: proprioception for healthy knees, gait and balance for osteoarthritic knees, and functional improvement of injured knees. This review suggests that knee sleeves can effect functional improvements to knee problems. However, further work is needed to confirm this hypothesis, due to the lack of homogeneity and rigor of existing studies. Copyright © 2017 Elsevier Ltd. All rights reserved.
Compressible sleeve provides automatic centering for grinding or turning of cylinders
NASA Technical Reports Server (NTRS)
Rohrer, J. A.
1968-01-01
Elastomeric sleeve supported on a threaded mandrel automatically centers cylindrical castings for grinding or turning. By expanding the diameter of the sleeve with pressure against the ends, the casting becomes rigidly supported and the surfacing operation can be completed.
Power control for heat engines
Dineen, John J.
1984-01-01
A power control arrangement for a Stirling engine includes a sleeve mounted in each cylinder for axial movement and a port in the sleeve leading to a dead space. The port is covered by the piston at a position that is determined by the piston position and the axial adjustment of the sleeve. The compression phase of the Stirling cycle for that piston begins when the port is covered, so the position of the sleeve is used to set the Stirling engine power level.
Sangkum, P; Levy, J; Yafi, F A; Hellstrom, W J G
2015-05-01
Urethral stricture disease, pelvic fracture urethral injury (PFUI), and their various treatment options are associated with erectile dysfunction (ED). The etiology of urethral stricture disease is multifactorial and includes trauma, inflammatory, and iatrogenic causes. Posterior urethral injuries are commonly associated with pelvic fractures. There is a spectrum in the severity of both conditions and this directly impacts the treatment options offered by the surgeon. Many published studies focus on the treatment outcomes and the relatively high recurrence rates after surgical repair. This communication reviews the current knowledge of the association between ED and urethral stricture disease, as well as PFUI. The incidence, pathophysiology, and clinical ramifications of both conditions on sexual function are discussed. The treatment options for ED in those patients are reviewed and summarized. © 2015 American Society of Andrology and European Academy of Andrology.
Nguyen, Ninh T; Smith, Brian R; Reavis, Kevin M; Nguyen, Xuan-Mai T; Nguyen, Brian; Stamos, Michael J
2012-05-01
Strategic laparoscopic surgery for improved cosmesis (SLIC) is a less invasive surgical approach than conventional laparoscopic surgery. The aim of this study was to examine the feasibility and safety of SLIC for general and bariatric surgical operations. Additionally, we compared the outcomes of laparoscopic sleeve gastrectomy with those performed by the SLIC technique. In an academic medical center, from April 2008 to December 2010, 127 patients underwent SLIC procedures: 38 SLIC cholecystectomy, 56 SLIC gastric banding, 26 SLIC sleeve gastrectomy, 1 SLIC gastrojejunostomy, and 6 SLIC appendectomy. SLIC sleeve gastrectomy was initially performed through a single 4.0-cm supraumbilical incision with extraction of the gastric specimen through the same incision. The technique evolved to laparoscopic incisions that were all placed within the umbilicus and suprapubic region. There were no 30-day or in-hospital mortalities or 30-day re-admissions or re-operations. For SLIC cholecystectomy, gastric banding, appendectomy, and gastrojejunostomy, conversion to conventional laparoscopy occurred in 5.3%, 5.4%, 0%, and 0%, respectively; there were no major or minor postoperative complications. For SLIC sleeve gastrectomy, there were no significant differences in mean operative time and length of hospital stay compared with laparoscopic sleeve gastrectomy; 1 (3.8%) of 26 SLIC patients required conversion to five-port laparoscopy. There were no major complications. Minor complications occurred in 7.7% in the SLIC sleeve group versus 8.3% in the laparoscopic sleeve group. SLIC in general and bariatric operations is technically feasible, safe, and associated with a low rate of conversion to conventional laparoscopy. Compared with laparoscopic sleeve gastrectomy, SLIC sleeve gastrectomy can be performed without a prolonged operative time with comparable perioperative outcomes.
Sleeve gastrectomy and anti-reflux procedures.
Crawford, Christopher; Gibbens, Kyle; Lomelin, Daniel; Krause, Crystal; Simorov, Anton; Oleynikov, Dmitry
2017-03-01
Obesity is an epidemic in the USA that continues to grow, becoming a leading cause of premature avoidable death. Bariatric surgery has become an effective solution for obesity and its comorbidities, and one of the most commonly utilized procedures, the sleeve gastrectomy, can lead to an increase in gastroesophageal reflux following the operation. While these data are controversial, sometimes operative intervention can be necessary to provide durable relief for this problem. We performed an extensive literature review examining the different methods of anti-reflux procedures that are available both before and after a sleeve gastrectomy. We reviewed several different types of anti-reflux procedures, including those that supplement the lower esophageal sphincter anatomy, such as magnetic sphincter augmentation and radiofrequency ablation procedures. Re-operation was also discussed as a possible treatment of reflux in sleeve gastrectomy, especially if the original sleeve becomes dilated or if a conversion to a Roux-en-Y gastric bypass or biliopancreatic diversion is deemed necessary. Sleeve gastrectomy with concomitant anti-reflux procedure was also reviewed, including the anti-reflux gastroplasty, hiatal hernia repair, and limited fundoplication. A number of techniques can be used to mitigate the severity of reflux, either by maintaining the normal anatomic structures that limit reflux or by supplementing these structures with a plication or gastroplasty. Individuals with existing severe reflux should not be considered for a sleeve gastrectomy. New techniques that incorporate plication at the time of the index sleeve gastrectomy show some improvement, but these are in small series that will need to be further evaluated. The only proven method of treating intractable reflux after sleeve gastrectomy is conversion to a Roux-en-Y gastric bypass.
High temperature control rod assembly
Vollman, Russell E.
1991-01-01
A high temperature nuclear control rod assembly comprises a plurality of substantially cylindrical segments flexibly joined together in succession by ball joints. The segments are made of a high temperature graphite or carbon-carbon composite. The segment includes a hollow cylindrical sleeve which has an opening for receiving neutron-absorbing material in the form of pellets or compacted rings. The sleeve has a threaded sleeve bore and outer threaded surface. A cylindrical support post has a threaded shaft at one end which is threadably engaged with the sleeve bore to rigidly couple the support post to the sleeve. The other end of the post is formed with a ball portion. A hollow cylindrical collar has an inner threaded surface engageable with the outer threaded surface of the sleeve to rigidly couple the collar to the sleeve. the collar also has a socket portion which cooperates with the ball portion to flexibly connect segments together to form a ball and socket-type joint. In another embodiment, the segment comprises a support member which has a threaded shaft portion and a ball surface portion. The threaded shaft portion is engageable with an inner threaded surface of a ring for rigidly coupling the support member to the ring. The ring in turn has an outer surface at one end which is threadably engageably with a hollow cylindrical sleeve. The other end of the sleeve is formed with a socket portion for engagement with a ball portion of the support member. In yet another embodiment, a secondary rod is slidably inserted in a hollow channel through the center of the segment to provide additional strength. A method for controlling a nuclear reactor utilizing the control rod assembly is also included.
Verit, Ayhan; Savas, Murat; Ciftci, Halil; Unal, Dogan; Yeni, Ercan; Kaya, Mete
2006-02-01
Urethral calculus is a rare form of urolithiasis with an incidence lower than 0.3%. We determined the outcomes of 15 patients with urethral stone, of which 8 were pediatric, including an undiagnosed primary fossa navicularis calculus. Fifteen consecutive male patients, of whom eight were children, with urethral calculi were assessed between 2000 and 2005 with a mean of 19 months' follow-up. All stones were fusiform in shape and solitary. Acute urinary retention, interrupted or weak stream, pain (penile, urethral, perineal) and gross hematuria were the main presenting symptoms in 7 (46.7%), 4 (26.7%), 3 (20%) and 1 (6.6%) patient, respectively. Six of them had accompanying urethral pathologies such as stenosis (primary or with hypospadias) and diverticulum. Two patients were associated with upper urinary tract calculi but none of them secondary to bladder calculi. A 50-year-old patient with a primary urethral stone disease had urethral meatal stenosis accompanied by lifelong lower urinary tract symptoms. Unlike the past reports, urethral stones secondary to bladder calculi were decreasing, especially in the pediatric population. However, the pediatric patients in their first decade are still under risk secondary to the upper urinary tract calculi or the primary ones.
Device for use in loading tension members. [characterized by elongated elastic body
NASA Technical Reports Server (NTRS)
Appleberry, W. T. (Inventor)
1975-01-01
The indicator is characterized by an elongated elastic body having extended from the opposite ends of threaded shanks adapted to selected tension members. A pair of external shoulders, one of which is axially displaceable relative to the other, and a rigid tubular sleeve interposed between said shoulders are included. Tension is applied to the elastic body for imparting strain. The movable shoulder can be advanced into abutting engagement with the sleeve, whereby the sleeve is placed in compression once the tensile forces are removed from the shanks. A reapplication of tensile forces equal to the initially applied tensile forces removes the sleeve from compression, whereby the sleeve is freed for rotation for thus indicating the magnitude of the applied tensile forces.
Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Nakano, Masahiro; Kubota, Yasuaki; Maeda, Sunaho; Ohtakara, Kazuhiro; Deguchi, Takashi; Hoshi, Hiroaki
2007-08-01
No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200(cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. The UrV150(cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume.
Rocha, Natalia P; Bastos, Fernando M; Vieira, Érica L M; Prestes, Thiago R R; Silveira, Katia D da; Teixeira, Mauro M; Simões E Silva, Ana Cristina
2018-03-11
Posterior urethral valve is the most common lower urinary tract obstruction in male children. A high percentage of patients with posterior urethral valve evolve to end-stage renal disease. Previous studies showed that cytokines, chemokines, and components of the renin-angiotensin system contribute to the renal damage in obstructive uropathies. The authors recently found that urine samples from fetuses with posterior urethral valve have increased levels of inflammatory molecules. The aim of this study was to measure renin-angiotensin system molecules and to investigate their correlation with previously detected inflammatory markers in the same urine samples of fetuses with posterior urethral valve. Urine samples from 24 fetuses with posterior urethral valve were collected and compared to those from 22 healthy male newborns at the same gestational age (controls). Renin-angiotensin system components levels were measured by enzyme-linked immunosorbent assay. Fetuses with posterior urethral valve presented increased urinary levels of angiotensin (Ang) I, Ang-(1-7) and angiotensin-converting enzyme 2 in comparison with controls. ACE levels were significantly reduced and Ang II levels were similar in fetuses with posterior urethral valve in comparison with controls. Increased urinary levels of angiotensin-converting enzyme 2 and of Ang-(1-7) in fetuses with posterior urethral valve could represent a regulatory response to the intense inflammatory process triggered by posterior urethral valve. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Onofre, Luciano Silveira; Leão, Jovelino Quintino de Souza; Gomes, Adriano Luis; Heinisch, Antonio Carlos; Leão, Fernanda Ghilardi; Carnevale, José
2011-06-01
Trauma injuries of the posterior urethra resulting from pelvic fracture in children tend to be complete ruptures, with upper dislocation of the prostate. This paper aims to show our experience in using an anterior sagittal transanorectal approach (ASTRA) in the treatment of such injuries. The medical records of 11 patients with pelvic fracture urethral distraction defects who had undergone anastomotic urethroplasty through ASTRA between 1997 and 2009 were reviewed. Ages ranged from 1 year and 6 months to 23 years (mean age 11 years). Of the 11 patients, 8 had previously undergone failed urethroplasties. In 10 patients it was possible to perform tension free urethroplasty. One patient required inferior pubectomy and separation of the corpora cavernosa. Patients' follow-up time varied from 10 months to 10 years and 9 months (mean 41 months). One patient had a urethral fistula and evolved with a urethral diverticulum successfully managed by diverticulectomy. One patient presented a urethral stenosis managed by urethral dilatation. Of the 11 patients, 9 presented functional urethral flow and are continent. Two patients had no urethral flow. One is undergoing bladder catheterization through the Mitrofanoff principle and the other one through the urethra. No patient presented fecal incontinence or rectourethral fistula. This access, which is increasingly being used to approach posterior urethral diseases, has proved to be safe and effective in the treatment of pelvic fracture urethral distraction defects. Copyright © 2011 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
To sling or not to sling at time of abdominal sacrocolpopexy: a cost-effectiveness analysis.
Richardson, Monica L; Elliott, Christopher S; Shaw, Jonathan G; Comiter, Craig V; Chen, Bertha; Sokol, Eric R
2013-10-01
We compare the cost-effectiveness of 3 strategies for the use of a mid urethral sling to prevent occult stress urinary incontinence in patients undergoing abdominal sacrocolpopexy. Using decision analysis modeling we compared cost-effectiveness during a 1-year postoperative period of 3 treatment approaches including 1) abdominal sacrocolpopexy alone with deferred option for mid urethral sling, 2) abdominal sacrocolpopexy with universal concomitant mid urethral sling and 3) preoperative urodynamic study for selective mid urethral sling. Using published data we modeled probabilities of stress urinary incontinence after abdominal sacrocolpopexy with or without mid urethral sling, the predictive value of urodynamic study to detect occult stress urinary incontinence and the likelihood of complications after mid urethral sling. Costs were derived from Medicare 2010 reimbursement rates. The main outcome modeled was incremental cost-effectiveness ratio per quality adjusted life-years gained. In addition to base case analysis, 1-way sensitivity analyses were performed. In our model, universally performing mid urethral sling at abdominal sacrocolpopexy was the most cost-effective approach with an incremental cost per quality adjusted life-year gained of $2,867 compared to abdominal sacrocolpopexy alone. Preoperative urodynamic study was more costly and less effective than universally performing intraoperative mid urethral sling. The cost-effectiveness of abdominal sacrocolpopexy plus mid urethral sling was robust to sensitivity analysis with a cost-effectiveness ratio consistently below $20,000 per quality adjusted life-year. Universal concomitant mid urethral sling is the most cost-effective prophylaxis strategy for occult stress urinary incontinence in women undergoing abdominal sacrocolpopexy. The use of preoperative urodynamic study to guide mid urethral sling placement at abdominal sacrocolpopexy is not cost-effective. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Menezes Filho, Jonas Rodrigues de; Sardinha, José Carlos Gomes; Galbán, Enrique; Saraceni, Valéria; Talhari, Carolina
2017-01-01
Urethral discharge syndrome (UDS) is characterized by the presence of purulent or mucopurulent urethral discharge.The main etiological agents of this syndrome are Neisseria gonorrhoeae and Chlamydia trachomatis. To evaluate the effectiveness of the syndromic management to resolve symptoms in male urethral discharge syndrome cases in Manaus, Amazonas, Brazil. Retrospective cohort of male cases of urethral discharge syndrome observed at a clinic for sexually transmitted disease (STD) in 2013. Epidemiological and clinical data, as well as the results of urethral swabs, bacterioscopy, hybrid capture for C.trachomatis, wet-mount examination, and culture for N.gonorrhoeae, were obtained through medical chart reviews. Of the 800 urethral discharge syndrome cases observed at the STD clinic, 785 (98.1%) presented only urethral discharge syndrome, 633 (79.1%) returned for follow-up, 579 (91.5%) were considered clinically cured on the first visit, 41(6.5 %) were considered cured on the second visit, and 13(2.0%) did not reach clinical cure after two appointments. Regarding the etiological diagnosis, 42.7% of the patients presented a microbiological diagnosis of N.gonorrhoeae, 39.3% of non-gonococcal and non-chlamydia urethritis, 10.7% of C.trachomatis and 7.3% of co-infection with chlamydia and gonococcus. The odds of being considered cured in the first visit were greater in those who were unmarried, with greater schooling, and with an etiological diagnosis of gonorrhea. The diagnosis of non-gonococcal urethritis reduced the chance of cure in the first visit. A study conducted at a single center of STD treatment. Syndromic management of male urethral discharge syndrome performed in accordance with the Brazilian Ministry of Health STD guidelines was effective in resolving symptoms in the studied population. More studies with microbiological outcomes are needed to ensure the maintenance of the syndromic management.
Shrinkable sleeve eliminates shielding gap in RF cable
NASA Technical Reports Server (NTRS)
1965-01-01
RF shielding gap between an RF cable and a multipin connector is eliminated by a sleeve assembly installed between the connector and the terminated portion of the shielding. The assembly is enclosed in a heat-shrinkable plastic sleeve which completes the continuous RF shield.
NASA Technical Reports Server (NTRS)
Bluck, Raymond M. (Inventor); Bush, Harold G. (Inventor); Johnson, Robert R. (Inventor)
1991-01-01
A process for producing seamless metal-clad composite structures includes providing a hollow, metallic inner member and an outer sleeve to surround the inner member and define an inner space therebetween. A plurality of continuous reinforcing fibers is attached to the distal end of the outside diameter of the inner member, and the inner member is then introduced, distal end first, into one end of the outer sleeve. The inner member is then moved, distal end first, into the outer sleeve until the inner member is completely enveloped by the outer sleeve. A liquid matrix material is then injected into the space containing the reinforcing fibers between the inner member and the outer sleeve. Next a pressurized heat transfer medium is passed through the inner member to cure the liquid matrix material. Finally, the wall thickness of both the inner member and the outer sleeve are reduced to desired dimensions by chemical etching, which adjusts the thermal expansion coefficient of the metal-clad composite structure to a desired value.
Quartararo, N; Barry, P H
1987-12-01
A technical problem associated with the patch clamp technique has been the changing of solutions bathing the membrane patch. The simple technique described here solves this problem by means of a movable polythene sleeve placed on the shaft of the patch clamp pipette. The sleeve is initially placed so that the tip of the pipette is exposed. A gigaohm seal is formed using standard techniques. The patch is then excised and the sleeve is slipped down a few mm past the end of the tip of the pipette. When the pipette and sleeve is now removed from the solution, a small drop of solution covering the membrane patch is held in place at the end of the sleeve by surface tension. The pipette is then easily transferred to a different solution without passing the membrane patch through the air-water interface. The sleeve is then simply pulled back up the pipette shaft to expose the membrane patch to the new solution.
McKay, M.D.; Sweeney, C.E.; Spangler, B.S. Jr.
1993-11-30
A flow meter and temperature measuring device are described comprising a tube with a body centered therein for restricting flow and a sleeve at the upper end of the tube to carry several channels formed longitudinally in the sleeve to the appropriate axial location where they penetrate the tube to allow pressure measurements and temperature measurements with thermocouples. The high pressure measurement is made using a channel penetrating the tube away from the body and the low pressure measurement is made at a location at the widest part of the body. An end plug seals the end of the device and holes at its upper end allow fluid to pass from the interior of the tube into a plenum. The channels are made by cutting grooves in the sleeve, the grooves widened at the surface of the sleeve and then a strip of sleeve material is welded to the grooves closing the channels. Preferably the sleeve is packed with powdered graphite before cutting the grooves and welding the strips. 7 figures.
High precision high flow range control valve
McCray, J.A.
1999-07-13
A fluid control valve is described having a valve housing having first and second valve housing openings for the ingress and egress of fluid through the control valve. Disposed within a void formed by the control valve is a sleeve having at least one sleeve opening to permit the flow of fluid therethrough. A flow restricter travels within the sleeve to progressively block off the sleeve opening and thereby control flow. A fluid passageway is formed between the first valve housing opening and the outer surface of the sleeve. A second fluid passageway is formed between the inside of the sleeve and the second valve housing opening. Neither fluid passageway contains more than one 90 [degree] turn. In the preferred embodiment only one of the two fluid passageways contains a 90[degree] turn. In another embodiment, the control valve housing is bifurcated by a control surface having control surface opening disposed therethrough. A flow restricter is in slidable contact with the control surface to restrict flow of fluid through the control surface openings. 12 figs.
High precision high flow range control valve
McCray, John A.
1999-01-01
A fluid control valve is described having a valve housing having first and second valve housing openings for the ingress and egress of fluid through the control valve. Disposed within a void formed by the control valve is a sleeve having at least one sleeve opening to permit the flow of fluid therethrough. A flow restricter travels within the sleeve to progressively block off the sleeve opening and thereby control flow. A fluid passageway is formed between the first valve housing opening and the outer surface of the sleeve. A second fluid passageway is formed between the inside of the sleeve and the second valve housing opening. Neither fluid passageway contains more than one 90.degree. turn. In the preferred embodiment only one of the two fluid passageways contains a 90.degree. turn. In another embodiment, the control valve housing is bifurcated by a control surface having control surface opening disposed therethrough. A flow restricter is in slidable contact with the control surface to restrict flow of fluid through the control surface openings.
Model of radiation transmittance by inorganic fouling on UV reactor lamp sleeves.
Wait, Isaac W; Blatchley, Ernest R
2010-11-01
The efficacy of UV disinfection of water depends on the ability of radiation to pass from UV lamps through the quartz sleeves that encase them; the accumulation of metal-containing foulants on sleeve surfaces inhibits disinfection by absorbing radiation that would otherwise be available for inactivation. In a series of experiments, the composition and quantity of sleeve foulants were studied relative to water chemistry and sleeve transmittance. Findings indicate that iron and calcium dominate fouling, with elevated fouling activity by iron, aluminum, manganese, and zinc. A regression-based modeling approach was used to characterize and quantify the effects of foulant metals on UV absorbance. The molar extinction coefficient for iron was found to be more than 3 times greater than that of calcium. Iron's relatively high activity in fouling reactions, elevated capacity to absorb UV, and reduced solubility under oxidizing conditions makes it a fouling precursor of particular concern, with respect to potential for sleeve fouling in UV reactors.
Mechanical counter pressure on the arm counteracts adverse effects of hypobaric exposures
NASA Technical Reports Server (NTRS)
Tanaka, Kunihiko; Limberg, Ryan; Webb, Paul; Reddig, Mike; Jarvis, Christine W.; Hargens, Alan R.
2003-01-01
INTRODUCTION: Current space suits have limited movement due to gas pressurization during exposure to the vacuum of space. Alternatively, if pressure is applied by an elastic garment vs. pneumatic garment to produce mechanical counter pressure (MCP), several advantages are possible. In this study, we investigate local microcirculatory and other effects produced with and without a prototype MCP glove and sleeve during exposure to varying levels of vacuum. METHODS: The entire arms of eight male volunteers were studied at normal ambient pressure and during 5 min exposures to -50, -100, and -150 mm Hg with and without the MCP glove and sleeve. Pressure distribution, skin microvascular flow, and temperature were measured. RESULTS: The MCP glove and sleeve generated over 200 mm Hg on the middle finger, dorsum of the hand, and the wrist. However, pressure was significantly lower on the forearm and the upper arm. Without the glove and sleeve, only two of eight subjects tolerated -100 mm Hg. Also, no subject tolerated -150 mm Hg. However, subjects tolerated all vacuum pressures wearing the glove and sleeve. Skin microvascular flow and temperature remained within control values with the glove and sleeve at a chamber pressure of -150 mm Hg. DISCUSSION: The MCP glove and sleeve counteracts adverse effects of vacuum exposures due to lower pressure differentials. Pressure levels over the hand and wrist are similar to those of the current U.S. space suit glove and sleeve, but additional development is required to increase MCP over the forearm and upper arm.
Dual Pathology Causing Congenital Bladder Outlet Obstruction.
Kwong, Ruth; Johal, Navroop S; Upasani, Anand; Paul, Anu; Cuckow, Peter
2017-12-07
Anterior urethral syringocele is an uncommon congenital deformity characterised by cystic dilatation of bulbo-urethral gland ducts and is usually asymptomatic. We present a case on 4-day-old male neonate who presented with bilateral antenatal hydroureteronephrosis and renal impairment and found to have urethral syringocele and posterior urethral valves (PUV). Copyright © 2017. Published by Elsevier Inc.
2013-05-01
Distal Urethral Cancer; Metastatic Transitional Cell Cancer of the Renal Pelvis and Ureter; Proximal Urethral Cancer; Recurrent Bladder Cancer; Recurrent Transitional Cell Cancer of the Renal Pelvis and Ureter; Recurrent Urethral Cancer; Stage IV Bladder Cancer; Transitional Cell Carcinoma of the Bladder; Urethral Cancer Associated With Invasive Bladder Cancer
Sigdel, G; Agarwal, A; Keshaw, B W
2014-01-01
Urethral calculi are rare forms of urolithiasis. Majority of the calculi are migratory from urinary bladder or upper urinary tract. Primary urethral calculi usually occur in presence of urethral stricture or diverticulum. In this article we report a case of a giant posterior urethral calculus measuring 7x3x2 cm in a 47 years old male. Patient presented with acute retention of urine which was preceded by burning micturition and dribbling of urine for one week. The calculus was pushed in to the bladder through the cystoscope and was removed by suprapubic cystolithotomy.
Fukui, Shinji; Aoki, Katsuya; Kaneko, Yoshiteru; Samma, Shoji; Fujimoto, Kiyohide
2014-01-01
A 2-month-old boy was diagnosed with febrile urinary tract infection. Voiding cystourethrography showed bulbar and anterior urethral strictures, and endoscopic internal urethrotomy was performed. He developed febrile urinary tract infection again and revealed the recurrence of the anterior urethral stricture. Consequently, endoscopic internal urethrotomy was performed 4 times. Because the anterior urethral stricture had not improved, he was referred to us. Anterior urethroplasty was performed when he was 5 years. After excision of the scarred portions of the urethra, the defect of the urethra was 20 mm. Transperineal bulbar urethral mobilization was performed, and a single-stage end-to-end anterior urethroplasty without tension could be performed simultaneously. PMID:26955558
Fukui, Shinji; Aoki, Katsuya; Kaneko, Yoshiteru; Samma, Shoji; Fujimoto, Kiyohide
2014-05-01
A 2-month-old boy was diagnosed with febrile urinary tract infection. Voiding cystourethrography showed bulbar and anterior urethral strictures, and endoscopic internal urethrotomy was performed. He developed febrile urinary tract infection again and revealed the recurrence of the anterior urethral stricture. Consequently, endoscopic internal urethrotomy was performed 4 times. Because the anterior urethral stricture had not improved, he was referred to us. Anterior urethroplasty was performed when he was 5 years. After excision of the scarred portions of the urethra, the defect of the urethra was 20 mm. Transperineal bulbar urethral mobilization was performed, and a single-stage end-to-end anterior urethroplasty without tension could be performed simultaneously.
Anterior urethral stricture review
Stein, Marshall J.
2013-01-01
Male anterior urethral stricture disease is a commonly encountered condition that presents to many urologists. According to a National Practice Survey of Board Certified Urologist in the United States most urologists treat on average 6-20 urethral strictures yearly. Many of those same urologists surveyed treat with repeated dilation or internal urethrotomy, despite continual recurrence of the urethral stricture. In point of fact, the urethroplasty despite its high success rate, is underutilized by many practicing urologists. Roughly half of practicing urologist do not perform urethroplasty in the United States. Clearly, the reconstructive ladder for urethral stricture management that was previously described in the literature may no longer apply in the modern era. The following article reviews the etiology, diagnosis, management and comparisons of treatment options for anterior urethral strictures. PMID:26816721
76 FR 59116 - Procurement List; Additions
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-23
... NSN: AF110--Shirt, Class A/Primary Duty, USAF, Men's, Long Sleeve, Dark Navy Blue, Numerous Sizes. NSN: AF111--Shirt, Class A/Primary Duty, USAF, Women's, Long Sleeve, Dark Navy Blue, Numerous Sizes. NSN: AF120--Shirt, Class A/Primary Duty, USAF, Men's, Short Sleeve, Dark Navy Blue, Numerous Sizes. NSN...
Use of color-coded sleeve shutters accelerates oscillograph channel selection
NASA Technical Reports Server (NTRS)
Bouchlas, T.; Bowden, F. W.
1967-01-01
Sleeve-type shutters mechanically adjust individual galvanometer light beams onto or away from selected channels on oscillograph papers. In complex test setups, the sleeve-type shutters are color coded to separately identify each oscillograph channel. This technique could be used on any equipment using tubular galvanometer light sources.
Dynamic, High-Temperature, Flexible Seal
NASA Technical Reports Server (NTRS)
Steinetz, Bruce M.; Sirocky, Paul J.
1989-01-01
New seal consists of multiple plies of braided ceramic sleeves filled with small ceramic balls. Innermost braided sleeve supported by high-temperature-wire-mesh sleeve that provides both springback and preload capabilities. Ceramic balls reduce effect of relatively high porosity of braided ceramic sleeves by acting as labyrinth flow path for gases and thereby greatly increasing pressure gradient seal can sustain. Dynamic, high-temperature, flexible seal employed in hypersonic engines, two-dimensional convergent/divergent and vectorized-thrust exhaust nozzles, reentry vehicle airframes, rocket-motor casings, high-temperature furnaces, and any application requiring non-asbestos high-temperature gaskets.
Inductively coupled plasma torch with laminar flow cooling
Rayson, Gary D.; Shen, Yang
1991-04-30
An improved inductively coupled gas plasma torch. The torch includes inner and outer quartz sleeves and tubular insert snugly fitted between the sleeves. The insert includes outwardly opening longitudinal channels. Gas flowing through the channels of the insert emerges in a laminar flow along the inside surface of the outer sleeve, in the zone of plasma heating. The laminar flow cools the outer sleeve and enables the torch to operate at lower electrical power and gas consumption levels additionally, the laminar flow reduces noise levels in spectroscopic measurements of the gaseous plasma.
Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew
2014-03-01
Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.
Sleeve gastrectomy and gastro-oesophageal reflux disease: a complex relationship.
Mahawar, Kamal K; Jennings, Neil; Balupuri, Shlok; Small, Peter K
2013-07-01
Sleeve gastrectomy is rapidly becoming popular as a standalone bariatric operation. At the same time, there are valid concerns regarding its long-term durability and postoperative gastro-oesophageal reflux disease. Though gastric bypass remains the gold standard bariatric operation, it is not suitable for all patients. Sleeve gastrectomy is sometimes the only viable option. Patients with inflammatory bowel disease, liver cirrhosis, significant intra-abdominal adhesions involving small bowel and those reluctant to undergo gastric bypass could fall in this category. It is widely recognised that some patients report worsening of their gastro-oesophageal reflux disease after sleeve gastrectomy. Still, others develop de novo reflux. This review examines if it is possible to identify these patients prior to surgery and thus prevent postoperative gastro-oesophageal reflux disease after sleeve gastrectomy.
Downhole steam generator with improved preheating/cooling features
Donaldson, A. Burl; Hoke, Donald E.; Mulac, Anthony J.
1983-01-01
An apparatus for downhole steam generation employing dual-stage preheaters for liquid fuel and for the water. A first heat exchange jacket for the fuel surrounds the fuel/oxidant mixing section of the combustor assembly downstream of the fuel nozzle and contacts the top of the combustor unit of the combustor assembly, thereby receiving heat directly from the combustion of the fuel/oxidant. A second stage heat exchange jacket surrounds an upper portion of the oxidant supply line adjacent the fuel nozzle receiving further heat from the compression heat which results from pressurization of the oxidant. The combustor unit includes an inner combustor sleeve whose inner wall defines the combustion zone. The inner combustor sleeve is surrounded by two concentric water channels, one defined by the space between the inner combustor sleeve and an intermediate sleeve, and the second defined by the space between the intermediate sleeve and an outer cylindrical housing. The channels are connected by an annular passage adjacent the top of the combustor assembly and the countercurrent nature of the water flow provides efficient cooling of the inner combustor sleeve. An annular water ejector with a plurality of nozzles is provided to direct water downwardly into the combustor unit at the boundary of the combustion zone and along the lower section of the intermediate sleeve.
Downhole steam generator with improved preheating/cooling features. [Patent application
Donaldson, A.B.; Hoke, D.E.; Mulac, A.J.
1980-10-10
An apparatus is described for downhole steam generation employing dual-stage preheaters for liquid fuel and for the water. A first heat exchange jacket for the fuel surrounds the fuel/oxidant mixing section of the combustor assembly downstream of the fuel nozzle and contacts the top of the combustor unit of the combustor assembly, thereby receiving heat directly from the combustion of the fuel/oxidant. A second stage heat exchange jacket surrounds an upper portion of the oxidant supply line adjacent the fuel nozzle receiving further heat from the compression heat which results from pressurization of the oxidant. The combustor unit includes an inner combustor sleeve whose inner wall defines the combustion zone. The inner combustor sleeve is surrounded by two concentric water channels, one defined by the space between the inner combustor sleeve and an intermediate sleeve, and the second defined by the space between the intermediate sleeve and an outer cylindrical housing. The channels are connected by an annular passage adjacent the top of the combustor assembly and the countercurrent nature of the water flow provides efficient cooling of the inner combustor sleeve. An annular water ejector with a plurality of nozzles is provided to direct water downwardly into the combustor unit at the boundary of the combustion zone and along the lower section of the intermediate sleeve.
Female urethral injuries associated with pelvic fracture: a systematic review of the literature.
Patel, Devin N; Fok, Cynthia S; Webster, George D; Anger, Jennifer T
2017-12-01
To review systematically the literature on female urethral injuries associated with pelvic fracture and to determine the optimum management of this rare injury. Using Meta-analysis of Observational Studies in Epidemiology criteria, we searched the Cochrane, Pubmed and OVID databases for all articles available before 30 June 2016 using the terms 'female pelvic fracture urethroplasty', 'female urethral distraction', 'female pelvic fracture urethral injury' and 'female pelvic fracture urethra girls.' Two authors of this paper independently reviewed the titles, abstracts, and articles in duplicate. We identified 162 individual articles from the databases. Fifty-one articles met our criteria for full review, including 158 female patients with urethral trauma. Of these injuries, 83 (53%) were managed with immediate repair; 17/83 (20%) via primary alignment and 66/83 (80%) via anastomotic repair. The remaining 75/158 (47%) were managed with delayed repair. Rates of urethral stenosis and fistula were highest after primary alignment. Urethral integrity appears to be similar after both primary anastomosis and delayed repair; however, patients experienced significantly more incontinence and vaginal stenosis after delayed repair. Patients who underwent delayed urethral repair were more likely to undergo more extensive reconstructive surgery than those who underwent primary repair. The optimum management of female urethral distraction defects is based on very-low-quality literature. Based on our review of the available literature, primary anastomotic repair of a female urethral distraction defect via a vaginal approach as soon as the patient is haemodynamically stable appears to be optimal. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.
A descriptive study of urethral discharge among men in Fiji.
Gaunavinaka, Lavenia; Balak, Dashika; Varman, Sumanthla; Ram, Sharan; Graham, Stephen M
2014-10-17
Urethral discharge is a common presentation of sexually transmitted infection (STI) in men and known pathogens include Neisseria gonorrhoeae and Chlamydia trachomatis. There are no published data of the burden of urethral discharge among men in Fiji. To evaluate urethral discharge among men to determine the incidence, the frequency of recurrence and reported at-risk behaviour. We conducted a retrospective, descriptive study of clinical records of all men presenting with urethral discharge to two major reproductive health clinics. Data collected included self-reported at-risk behaviours, results of abnormal syphilis serology and antibiotics prescribed. The frequency of recurrence in the following 1-2 years of initial presentation was determined along with microbiological findings from urethral swab in this group. A total of 748 males presented with urethral discharge to the clinic in one year. This represents an incidence rate of at least 295 per 100,000 adult males per year in the study population. Within the next 1-2 years of the initial presentation, 102 (14%) of these re-presented out of which 42 had urethral swab taken for etiological diagnosis. The commonest isolate was Neisseria gonorrhoeae. Results of syphilis tests were available for 560 (75%) of patients and 29 (5%) were positive. Recurrence was not associated with self-reported at-risk behaviours. The incidence of urethral discharge among males in Fiji is very high and prevention strategies are urgently needed.
Pépin, J.; Sobéla, F.; Deslandes, S.; Alary, M.; Wegner, K.; Khonde, N.; Kintin, F.; Kamuragiye, A.; Sylla, M.; Zerbo, P. J.; Baganizi, E.; Koné, A.; Kane, F.; Mâsse, B.; Viens, P.; Frost, E.
2001-01-01
OBJECTIVE: To determine the etiological role of pathogens other than Neisseria gonorrhoeae and Chlamydia trachomatis in urethral discharge in West African men. METHODS: Urethral swabs were obtained from 659 male patients presenting with urethral discharge in 72 primary health care facilities in seven West African countries, and in 339 controls presenting for complaints unrelated to the genitourinary tract. Polymerase chain reaction analysis was used to detect the presence of N. gonorrhoeae, C. trachomatis, Trichomonas vaginalis, Mycoplasma genitalium, and Ureaplasma urealyticum. FINDINGS: N. gonorrhoeae, T. vaginalis, C. trachomatis, and M. genitalium--but not U. urealyticum--were found more frequently in men with urethral discharge than in asymptomatic controls, being present in 61.9%, 13.8%, 13.4% and 10.0%, respectively, of cases of urethral discharge. Multiple infections were common. Among patients with gonococcal infection, T. vaginalis was as frequent a coinfection as C. trachomatis. M. genitalium, T. vaginalis, and C. trachomatis caused a similar clinical syndrome to that associated with gonococcal infection, but with a less severe urethral discharge. CONCLUSIONS: M. genitalium and T. vaginalis are important etiological agents of urethral discharge in West Africa. The frequent occurrence of multiple infections with any combination of four pathogens strongly supports the syndromic approach. The optimal use of metronidazole in flowcharts for the syndromic management of urethral discharge needs to be explored in therapeutic trials. PMID:11242818
Kranz, J; Maurer, G; Maurer, U; Deserno, O; Schulte, S; Steffens, J
2017-03-01
A urethral stricture is a scar of the urethral epithelium which can cause obstructive voiding dysfunction with consequential damage of the upper urinary tract. Almost 45% of all strictures are iatrogenic; they develop in 2-9% of patients after radical prostatectomy, but can also occur after prostate cancer radiotherapy. This study provides 5‑year data of a certified prostate cancer center (PKZ) in terms of urethral strictures. Between 01/2008 and 12/2012 a total of 519 men were irradiated for prostate cancer (LDR and HDR brachytherapy as well as external beam radiation). The entire cohort was followed-up prospectively according to a standardized protocol (by type of irradiation). Short segment urethral strictures were treated by urethrotomy, recurrent and long segment stenosis with buccal mucosa urethroplasty. A total of 18 of 519 (3.4%) patients developed a urethral stricture post-therapeutically, which recurred in 66% of cases after the first operative treatment. The largest risk for developing a urethral stricture is attributed to the HDR brachytherapy (8.9%). Urethral strictures after prostate cancer radiotherapy should be diagnosed and treated in time for long-term preservation of renal function. The rate of radiogenic urethral strictures (3.4%) is equivalent to those after radical prostatectomy. Due to a high rate of recurrences, urethrotomy has a limited importance after irradiation.
[Clinical studies on lower urinary tract injury].
Tanaka, M; Ozono, S; Takashima, K; Yoshida, K; Hirao, Y; Okajima, E; Kaneko, Y; Tabata, S; Yoshida, K; Moriya, A
1997-01-01
A total of 61 patients with lower urinary tract injuries were treated at Nara Medical University and its affiliated hospitals, between January 1985 and June 1995. There were 9 patients with bladder injuries and 52 patients with urethral injuries. The main cause of bladder injury was a traffic accident sustained in 4 patients (44.5%) and that of urethral injury was an occupational accident sustained in 27 cases (51.9%). The major associated injuries were a bone fracture seen in 45 patients (73.8%) and an intrascrotal hematoma seen in 28 patients (45.9%). Posterior urethral injuries associated with pelvic bone fractures were classified into 3 types according to the classification reported by Colapinto et al.; 8 patients (32.0%) into Type I, 8 (32.0%) into Type II and 9 (36.0%) into Type III. Of the 25 patients with posterior urethral injuries, 8 (32.0%) underwent immediate surgical treatment, 12 (48.0%) underwent initial cystostomies and delayed surgical treatment and 5 (20.0%) received indwelling of urethral catheters. Postoperative complications of urethral injury included urethral stricture in 30 patients (57.7%), incontinence in 3 (5.8%) and impotence in 3 (5.8%). A significant relationship between the duration of cystostomy and the incidence of postoperative urethral stricture was observed in our patients. Therefore at least three weeks of cystostomy will be necessary in the management of patients with complicated urethral injuries.
Results of surgical excision of urethral prolapse in symptomatic patients.
Hall, Mary E; Oyesanya, Tola; Cameron, Anne P
2017-11-01
Here, we present the clinical presentation and surgical outcomes of women with symptomatic urethral prolapse presenting to our institution over 20 years, and seek to provide treatment recommendations for management of symptomatic urethral prolapse and caruncle. A retrospective review of medical records from female patients who underwent surgery for symptomatic urethral prolapse from June 1995 to August 2015 was performed. Surgical technique consisted of a four-quadrant excisional approach for repair of urethral prolapse. A total of 26 patients were identified with a mean age of 38.8 years (range 3-81). The most common presentations were vaginal bleeding, hematuria, pain, and dysuria. All patients underwent surgical excision of urethral prolapse via a standard approach. Follow-up data was available in 24 patients. Six patients experienced temporary postoperative bleeding, and one patient required placement of a Foley catheter for tamponade. One patient experienced temporary postoperative urinary retention requiring Foley catheter placement. Three patients had visible recurrence of urethral prolapse, for which one later underwent re-excision. Surgical excision of urethral prolapse is a reasonable treatment option in patients who have tried conservative management without relief, as well as in those who present with severe symptoms. Possible complications following excision include postoperative bleeding and recurrence, and patients must be counseled accordingly. In this work, we propose a treatment algorithm for symptomatic urethral prolapse. © 2017 Wiley Periodicals, Inc.
Radhakrishnan, A
2017-03-01
Urethral stent placement is an interventional treatment option to alleviate urethral outflow obstruction. It has been described utilizing fluoroscopy, but fluoroscopy is not as readily available in private practice as digital radiography. To describe the use of digital radiography for urethral stent placement in dogs with obstructive uropathy. Twenty-six client-owned dogs presented for dysuria associated with benign and malignant causes of obstructive uropathy that underwent urethral stent placement. Retrospective study. Causes of obstructive uropathy included transitional cell carcinoma, prostatic carcinoma, hemangiosarcoma, obstructive proliferative urethritis, compressive vaginal leiomyosarcoma, and detrusor-sphincter dyssynergia. Survival time range was 1-48 months (median, 5 months). All dogs were discharged from the hospital with urine outflow restored. Intraprocedural complications included guide wire penetration of the urethral wall in 1 dog and improper stent placement in a second dog. Both complications were successfully managed at the time of the procedure with no follow-up problems noted in either patient. Urethral stent placement can be successfully performed utilizing digital radiography. The complications experienced can be avoided by more cautious progression with each step through the procedure and serial radiography. The application of digital radiography may allow treatment of urethral obstruction to become more readily available. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Method and apparatus for shape and end position determination using an optical fiber
NASA Technical Reports Server (NTRS)
Moore, Jason P. (Inventor)
2010-01-01
A method of determining the shape of an unbound optical fiber includes collecting strain data along a length of the fiber, calculating curvature and bending direction data of the fiber using the strain data, curve-fitting the curvature and bending direction data to derive curvature and bending direction functions, calculating a torsion function using the bending direction function, and determining the 3D shape from the curvature, bending direction, and torsion functions. An apparatus for determining the 3D shape of the fiber includes a fiber optic cable unbound with respect to a protective sleeve, strain sensors positioned along the cable, and a controller in communication with the sensors. The controller has an algorithm for determining a 3D shape and end position of the fiber by calculating a set of curvature and bending direction data, deriving curvature, bending, and torsion functions, and solving Frenet-Serret equations using these functions.
2014-01-27
Anterior Urethral Cancer; Localized Transitional Cell Cancer of the Renal Pelvis and Ureter; Posterior Urethral Cancer; Recurrent Bladder Cancer; Recurrent Urethral Cancer; Regional Transitional Cell Cancer of the Renal Pelvis and Ureter; Stage III Bladder Cancer; Transitional Cell Carcinoma of the Bladder; Ureter Cancer; Urethral Cancer Associated With Invasive Bladder Cancer
Management of infected urethral diverticulum with urethral dilation.
Lazarou, George; Andrikopoulou, Maria; Cho, Sylvia
2015-01-01
Urethral diverticula are rare but underdiagnosed entities that may cause a variety of urinary and pelvic symptoms in women. Management can be very challenging, especially in cases of chronic infection. A 69-year-old gravida 4, para 2 woman with a history of type 2 diabetes and hypothyroidism presented with long history of a painful midline 3-cm suburethral cystic mass, recurrent urinary tract infections, dysuria, dyspareunia, and incomplete voiding. The diagnosis was consistent with an infected urethral diverticulum unresponsive to multiple courses of oral antibiotics. Given the patient's comorbidities and the persistence of infection of the diverticulum, conservative treatment with urethral dilation was performed before surgical treatment. Urethral dilation successfully alleviated the patient's symptoms; the surgical treatment was not ultimately required, and the patient continues to be completely asymptomatic well over 17 months later. We present a unique case of infected urethral diverticulum, which was conservatively treated with dilatation and resulted in resolution of all symptoms, and there is no need for further surgical management.
Pelvic fracture urethral injuries: evaluation of various methods of management.
Koraitim, M M
1996-10-01
The results of various immediate treatments of urethral injuries complicating a fractured pelvis were evaluated. The records of 100 male patients with pelvic fracture urethral injury were reviewed, 73 of whom were treated by suprapubic cystostomy and delayed repair, 23 by primary realignment and 4 by primary suturing. Also, the findings of 771 patients reported in the literature were reviewed. Urethral stricture was an almost inevitable consequence (97% of the cases) after suprapubic cystostomy. Primary realignment decreased the incidence of stricture to 53% but produced a 36% impotence rate. Primary suturing also decreased the incidence of stricture to 49% but produced the greatest complication rates for impotence (56%) and incontinence (21%). Suprapubic cystostomy alone is indicated for incomplete urethral rupture, slight urethral distraction and critically unstable patients, and when there are inadequate facilities or inexperienced surgeons. Primary realignment is advised if there is wide separation of the urethral ends, or associated injury of the bladder neck or rectum. Primary suturing is not recommended for any condition.
Current Management of Urethral Stricture
Lee, Young Ju
2013-01-01
The surgical treatment of urethral stricture diseases is continually evolving. Although various surgical techniques are available for the treatment of anterior urethral stricture, no one technique has been identified as the method of choice. This article provides a brief updated review of the surgical options for the management of different sites and different types of anterior urethral stricture. This review also covers present controversies in urethral reconstruction. Among the various procedures available for treating urethral stricture, one-stage buccal mucosal graft urethroplasty is currently widely used. The choice of technique for urethroplasty for an individual case largely depends on the expertise of the surgeon. Therefore, urologists working in this field should keep themselves updated on the numerous surgical techniques to deal with any condition of the urethra that might surface at the time of surgery. PMID:24044088
Acute urinary retention in women due to urethral calculi: A rare case
Turo, Rafal; Smolski, Michal; Kujawa, Magda; Brown, Stephen C.W.; Brough, Richard; Collins, Gerald N.
2014-01-01
We present a case of a 51-year-old woman with acute urinary retention caused by a urethral calculus. Urethral calculi in women are extremely rare and are usually formed in association with underlying genitourinary pathology. In this case, however, no pathology was detected via thorough urological evaluation. We discuss the pathogenesis, clinical presentation and treatment of urethral calculi. To our knowledge, this is the second reported case of a primary urethral calculus in a female with an anatomically normal urinary tract and the first in a middle-aged Caucasian female. PMID:24554984
Gomes de Souza Pegorare, Ana Beatriz; Gonçalves, Marco Antonio; Martiniano de Oliveira, Alessandra; Rodrigues Junior, Antonio Antunes; Tucci, Silvio; Suaid, Haylton Jorge
2014-04-01
To evaluate the effect of diabetes mellitus and of sildenafil citrate on female urethral function. Twenty nine female rats were divided into four groups: G1 - (n=9), normal rats; G2 - (n=6), normal rats treated with sildenafil citrate; G3 - (n=9) rats with alloxan-induced diabetes; G4 - (n=5) rats with alloxan-induced diabetes treated with sildenafil citrate. Under anesthesia, urodynamic evaluation was performed by cystometry and urethral pressure simultaneously. A significant increase in urethral pressure was observed during micturition. Sildenafil citrate can partially reduced urethral pressure in diabetic female rats.
NASA Astrophysics Data System (ADS)
Karrenberg, Gregor; Wortberg, Johannes
2015-05-01
The High-Speed-S-Truder with floating screw sleeve is an alternative extrusion concept with solid-melt-separation. A fairly conventional 35 mm screw with a length of 21 D, which is accelerated by a 75 kW gearless, water cooled synchronous drive, conveys the resin into a 60 mm screw sleeve with a length of 10 D. Inside the sleeve the material is plasticizied and discharged into the outer screw channel of the sleeve through radial bores. Only the solid bed remains inside. The development of a melt pool - and thus a decrease of the plasticizing capacity - is avoided. The sleeve is rotated by drag forces only (approximately 10 - 15 % of the screw speed). Due to the low speed of the screw sleeve molten material is conveyed to a 4 D Dynamic Mixing Ring in a gentle manner. The DMRs floating ring and the screw sleeve are directly coupled. The granules in the screw channel are stopped by a barrier on the screw in front of the mixing device. So nearly no unmelted material can pass the system. For temperature management in the plastification and mixing zone a 3-zone heating/air-cooling system is used. Various kinds of experiments with the High-Speed S-Truder were conducted. Reachable throughputs with different types of material (LDPE, LLDPE, PP, PS) have been tested. Also three screw geometries, which are mainly varying in the channel depth, were compared. Experimental results and theoretical background will be described in this paper.
Pelvic fracture urethral injuries in girls.
Podestá, M L; Jordan, G H
2001-05-01
Injuries to the female urethra associated with pelvic fracture are uncommon. They may vary from urethral contusion to partial or circumferential rupture. When disruption has occurred at the level of the proximal urethra, it is usually complete and often associated with vaginal laceration. We retrospectively reviewed the records of a series of girls with pelvic fracture urethral stricture and present surgical treatment to restore urethral continuity and the outcome. Between 1984 and 1997, 8 girls 4 to 16 years old (median age 9.6) with urethral injuries associated with pelvic fracture were treated at our institutions. Immediate therapy involved suprapubic cystostomy in 4 cases, urethral catheter alignment and simultaneous suprapubic cystostomy in 3, and primary suturing of the urethra, bladder neck and vagina in 1. Delayed 1-stage anastomotic repair was performed in 1 patient with urethral avulsion at the level of the bladder neck and in 5 with a proximal urethral distraction defect, while a neourethra was constructed from the anterior vaginal wall in a 2-stage procedure in 1 with mid urethral avulsion. Concomitant vaginal rupture in 7 cases was treated at delayed urethral reconstruction in 5 and by primary repair in 2. The surgical approach was retropubic in 3 cases, vaginal-retropubic in 1 and vaginal-transpubic in 4. Associated injuries included rectal injury in 3 girls and bladder neck laceration in 4. Overall postoperative followup was 6 months to 6.3 years (median 3 years). Urethral obliteration developed in all patients treated with suprapubic cystostomy and simultaneous urethral realignment. The stricture-free rate for 1-stage anastomotic repair and substitution urethroplasty was 100%. In 1 girl complete urinary incontinence developed, while another has mild stress incontinence. Retrospectively the 2 incontinent girls had had an associated bladder neck injury at the initial trauma. Two recurrent vaginal strictures were treated successfully with additional transpositions of lateral labial flaps. This study emphasizes that combined vaginal-partial transpubic access is a reliable approach for resolving complex obliterative urethral strictures and associated urethrovaginal fistulas or severe bladder neck damage after traumatic pelvic fracture injury in female pediatric patients. Although our experience with the initial management of these injuries is limited, we advocate early cystostomy drainage and deferred surgical reconstruction when life threatening clinical conditions are present or extensive traumatized tissue in the affected area precludes immediate ideal surgical repair.
Salminen, Paulina; Helmiö, Mika; Ovaska, Jari; Juuti, Anne; Leivonen, Marja; Peromaa-Haavisto, Pipsa; Hurme, Saija; Soinio, Minna; Nuutila, Pirjo; Victorzon, Mikael
2018-01-16
Laparoscopic sleeve gastrectomy for treatment of morbid obesity has increased substantially despite the lack of long-term results compared with laparoscopic Roux-en-Y gastric bypass. To determine whether laparoscopic sleeve gastrectomy and laparoscopic Roux-en-Y gastric bypass are equivalent for weight loss at 5 years in patients with morbid obesity. The Sleeve vs Bypass (SLEEVEPASS) multicenter, multisurgeon, open-label, randomized clinical equivalence trial was conducted from March 2008 until June 2010 in Finland. The trial enrolled 240 morbidly obese patients aged 18 to 60 years, who were randomly assigned to sleeve gastrectomy or gastric bypass with a 5-year follow-up period (last follow-up, October 14, 2015). Laparoscopic sleeve gastrectomy (n = 121) or laparoscopic Roux-en-Y gastric bypass (n = 119). The primary end point was weight loss evaluated by percentage excess weight loss. Prespecified equivalence margins for the clinical significance of weight loss differences between gastric bypass and sleeve gastrectomy were -9% to +9% excess weight loss. Secondary end points included resolution of comorbidities, improvement of quality of life (QOL), all adverse events (overall morbidity), and mortality. Among 240 patients randomized (mean age, 48 [SD, 9] years; mean baseline body mass index, 45.9, [SD, 6.0]; 69.6% women), 80.4% completed the 5-year follow-up. At baseline, 42.1% had type 2 diabetes, 34.6% dyslipidemia, and 70.8% hypertension. The estimated mean percentage excess weight loss at 5 years was 49% (95% CI, 45%-52%) after sleeve gastrectomy and 57% (95% CI, 53%-61%) after gastric bypass (difference, 8.2 percentage units [95% CI, 3.2%-13.2%], higher in the gastric bypass group) and did not meet criteria for equivalence. Complete or partial remission of type 2 diabetes was seen in 37% (n = 15/41) after sleeve gastrectomy and in 45% (n = 18/40) after gastric bypass (P > .99). Medication for dyslipidemia was discontinued in 47% (n = 14/30) after sleeve gastrectomy and 60% (n = 24/40) after gastric bypass (P = .15) and for hypertension in 29% (n = 20/68) and 51% (n = 37/73) (P = .02), respectively. There was no statistically significant difference in QOL between groups (P = .85) and no treatment-related mortality. At 5 years the overall morbidity rate was 19% (n = 23) for sleeve gastrectomy and 26% (n = 31) for gastric bypass (P = .19). Among patients with morbid obesity, use of laparoscopic sleeve gastrectomy compared with use of laparoscopic Roux-en-Y gastric bypass did not meet criteria for equivalence in terms of percentage excess weight loss at 5 years. Although gastric bypass compared with sleeve gastrectomy was associated with greater percentage excess weight loss at 5 years, the difference was not statistically significant, based on the prespecified equivalence margins. clinicaltrials.gov Identifier: NCT00793143.
Ixabepilone in Treating Patients With Advanced Urinary Tract Cancer
2013-01-23
Distal Urethral Cancer; Metastatic Transitional Cell Cancer of the Renal Pelvis and Ureter; Proximal Urethral Cancer; Recurrent Bladder Cancer; Recurrent Transitional Cell Cancer of the Renal Pelvis and Ureter; Recurrent Urethral Cancer; Regional Transitional Cell Cancer of the Renal Pelvis and Ureter; Stage III Bladder Cancer; Stage IV Bladder Cancer; Transitional Cell Carcinoma of the Bladder; Urethral Cancer Associated With Invasive Bladder Cancer
NASA Technical Reports Server (NTRS)
Burley, R. K.
1983-01-01
Electrochemical deburring removes burrs from assembled injector tubes. Since process uses liquid anodic dissolution in liquid electrolyte to proide deburring action, smoothes surfaces and edges in otherwise inaccessible areas. Tool consists of sleeve that contains metallic ring cathode. Sleeve is placed over tube, and electrolytic solution is forced to flow between tube and sleeve. The workpiece serves an anode.
78 FR 14934 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-08
... discrepancies of the wiring and surrounding Teflon sleeves of the fuel tank boost pumps and override/jettison... the wiring and sleeves with new parts, as necessary. The first SNPRM proposed to reduce the initial... inspections to detect discrepancies of the wiring and surrounding Teflon sleeves of the fuel tank boost pumps...
NASA Technical Reports Server (NTRS)
Bluck, Raymond M. (Inventor); Bush, Harold G. (Inventor); Johnson, Robert R. (Inventor)
1990-01-01
A metallic outer sleeve is provided which is capable of enveloping a hollow metallic inner member having continuous reinforcing fibers attached to the distal end thereof. The inner member is then introduced into outer sleeve until inner member is completely enveloped by outer sleeve. A liquid matrix member is then injected into space between inner member and outer sleeve. A pressurized heat transfer medium is flowed through the inside of inner member, thereby forming a fiber reinforced matrix composite material. The wall thicknesses of both inner member and outer sleeve are then reduced to the appropriate size by chemical etching, to adjust the thermal expansion coefficient of the metal-clad composite structure to the desired value. thereby forming a fiber reinforced matrix composite material. The wall thicknesses of both inner member and outer sleeve are then reduced to the appropriate size by chemical etching, to adjust the thermal expansion coefficient of the metal-clad composite structure to the desired value. The novelty of this invention resides in the development of a efficient method of producing seamless metal clad fiber reinforced organic matrix composite structures.
de Menezes Filho, Jonas Rodrigues; Sardinha, José Carlos Gomes; Galbán, Enrique; Saraceni, Valéria; Talhari, Carolina
2017-01-01
Background Urethral discharge syndrome (UDS) is characterized by the presence of purulent or mucopurulent urethral discharge.The main etiological agents of this syndrome are Neisseria gonorrhoeae and Chlamydia trachomatis. Objectives To evaluate the effectiveness of the syndromic management to resolve symptoms in male urethral discharge syndrome cases in Manaus, Amazonas, Brazil. Methods Retrospective cohort of male cases of urethral discharge syndrome observed at a clinic for sexually transmitted disease (STD) in 2013. Epidemiological and clinical data, as well as the results of urethral swabs, bacterioscopy, hybrid capture for C.trachomatis, wet-mount examination, and culture for N.gonorrhoeae, were obtained through medical chart reviews. Results Of the 800 urethral discharge syndrome cases observed at the STD clinic, 785 (98.1%) presented only urethral discharge syndrome, 633 (79.1%) returned for follow-up, 579 (91.5%) were considered clinically cured on the first visit, 41(6.5 %) were considered cured on the second visit, and 13(2.0%) did not reach clinical cure after two appointments. Regarding the etiological diagnosis, 42.7% of the patients presented a microbiological diagnosis of N.gonorrhoeae, 39.3% of non-gonococcal and non-chlamydia urethritis, 10.7% of C.trachomatis and 7.3% of co-infection with chlamydia and gonococcus. The odds of being considered cured in the first visit were greater in those who were unmarried, with greater schooling, and with an etiological diagnosis of gonorrhea. The diagnosis of non-gonococcal urethritis reduced the chance of cure in the first visit. Study limitation A study conducted at a single center of STD treatment. Conclusion Syndromic management of male urethral discharge syndrome performed in accordance with the Brazilian Ministry of Health STD guidelines was effective in resolving symptoms in the studied population. More studies with microbiological outcomes are needed to ensure the maintenance of the syndromic management. PMID:29364432
Method and apparatus for extracting tritium and preparing radioactive waste for disposal
Heung, Leung K.
1994-01-01
Apparatus for heating an object such as a nuclear target bundle to release and recover hydrogen and contain the disposable residue for disposal. The apparatus comprises an inverted furnace, a sleeve/crucible assembly for holding and enclosing the bundle, conveying equipment for placing the sleeve onto the crucible and loading the bundle into the sleeve/crucible, a lift for raising the enclosed bundle into the furnace, and hydrogen recovery equipment including a trap and strippers, all housed in a containment having negative internal pressure. The crucible/sleeve assembly has an internal volume that is sufficient to enclose and hold the bundle before heating; the crucible's internal volume is sufficient by itself to hold and enclose the bundle's volume after heating. The crucible can then be covered and disposed of; the sleeve, on the other hand, can be reused.
Apparatus and method for sealing perforated well casing
Blount, Curtis G.; Benham, Robert A.; Brock, Jerry L.; Emerson, John A.; Ferguson, Keith R.; Scheve, Donald F.; Schmidt, Joseph H.; Schuler, Karl W.; Stanton, Philip L.
1997-01-01
Perforations and other openings in well casings, liners and other conduits may be substantially blocked or sealed to prevent fluid flow between the casing or liner interior and an earth formation by placing a radially expansible sleeve adjacent the perforations or openings and urging the sleeve into forcible engagement with the casing or inner wall using an explosive charge. An apparatus including a radially contracted sleeve formed by a coiled plate member or a tubular member having flutes defined by external and internal folds, may be deployed into a well casing or liner through a production or injection tubing string and on the end of a flexible cable or coilable tubing. An explosive charge disposed on the apparatus and within the sleeve may be detonated to urge the sleeve into forcible engagement with the casing inner wall.
Apparatus and method for sealing perforated well casing
Blount, C.G.; Benham, R.A.; Brock, J.L.; Emerson, J.A.; Ferguson, K.R.; Scheve, D.F.; Schmidt, J.H.; Schuler, K.W.; Stanton, P.L.
1997-03-25
Perforations and other openings in well casings, liners and other conduits may be substantially blocked or sealed to prevent fluid flow between the casing or liner interior and an earth formation by placing a radially expansible sleeve adjacent the perforations or openings and urging the sleeve into forcible engagement with the casing or inner wall using an explosive charge. An apparatus including a radially contracted sleeve formed by a coiled plate member or a tubular member having flutes defined by external and internal folds, may be deployed into a well casing or liner through a production or injection tubing string and on the end of a flexible cable or coilable tubing. An explosive charge disposed on the apparatus and within the sleeve may be detonated to urge the sleeve into forcible engagement with the casing inner wall. 17 figs.
Intraoperative fracture of phacoemulsification sleeve
2010-01-01
Background We describe a case of intraoperative fracture of phacoemulsification sleeve during phacoemulsification surgery. Case presentation Phacoemulsification surgery was performed in the left eye of a 58-year-old lady with grade II nuclear sclerosis & grade I cortical cataract. Towards the end of quadrant removal, there was anterior chamber instability with impaired followability of nuclear fragments. The distal part of the fractured sleeve remained inside the anterior chamber upon removal of the phacoemulsification probe. The retained sleeve was retrieved with a pair of forceps through the corneal incision site, which did not require widening. There was no missing fragments retained intraocularly and the patient had an uneventful recovery with vision of 20/25 at three months post-operatively. Conclusion Phacoemulsification sleeve fracture is an uncommon complication. With early identification of this condition and proper management, major complications can be avoided. PMID:21118542
Han, Cong-Xiang; Xu, Wei-Jie; Li, Wei; Yu, Zhong-Ying; Li, Jin-Yu; Lin, Xia-Cong; Zhao, Li
2016-07-01
To study the clinical effect endoscopic realignment with drainage via a peel-away sheath in the treatment of urethral rupture. We treated 21 urethral rupture patients by endoscopic realignment with drainage via a peel-away sheath using normal saline for irrigation under the normal nephroscope or Li Xun nephroscope, followed by analysis of the clinical results. The operation was successfully accomplished in 20 cases but failed in 1 and none experienced urinary extravasation. In the 14 cases of bulbar urethral rupture, the mean operation time was (5.1±1.6) min and the mean Foley catheter indwelling time was (26.0±5.1) d. Urethral stricture developed in 57.1% (8/14) of the cases after catheter removal, of which 1 was cured by internal urethrotomy and the other 7 by urethral sound dilation, with an average maximum urinary flow rate of (18.8±1.8) ml/s at 12 months after operation. In the 6 cases of posterior urethral rupture, the mean operation time was (15.8±7.5) min and the mean Foley catheter indwelling time was 8 weeks. Urethral stricture developed in all the 6 cases after catheter removal, of which 3 cases were cured by urethral dilation, 1 by internal urethrotomy, and 2 by open urethroplasty. The average maxium urinary flow rate of the 4 cases exempt from open surgery was (17.9±1.9) ml/s at 12 months after operation. Endoscopic realignment with drainage via a peel-away sheath can keep the operative field clear, avoid intraoperative rinse extravasation, shorten the operation time, improve the operation success rate, and achieve satisfactory early clinical outcomes in the treatment of either bulbar or posterior urethral rupture.
On the etiology of the electric activity of the external anal and urethral sphincters.
Shafik, Ali A; Shafik, Ismail A; El Sibai, Olfat
2014-10-01
In a previous study, the external anal sphincter (EAS) in dogs, known to consist of skeletal muscle fibers, was proved to contain bundles of smooth muscle fibers in between as well. Cause of electric activity in the external anal and urethral sphincters is not known; the current study investigated this point. Slices from external anal and urethral sphincters of 21 cadavers (12 male, 9 female). Eighth were fully and mat wide neonates, 13 were adults, were stained with hematoxylin and eosin, Masson's trichrome and succinic dehydrogenase, and examined microscopically. Eighteen healthy volunteers, electromyography activity of their external anal and urethral sphincters was recorded at rest, on coughing, after pudendal nerve block and after drotaverine administration, (a smooth muscle relaxant). Anal and urethral pressures were also measured. Microscopic studies have shown that both external anal and urethral sphincters were formed of bundles of smooth muscle fibers present in between the skeletal muscle fibers. Bilateral pudendal nerve block did not abolish the external anal or the urethral sphincters electromyography activity at rest, or on coughing, and did not cause significant anal or urethral pressure changes (p > .05). Drotaverine administration lead to disappearance of the electromyography activity and significant decline of the anal and urethral pressures (p < .05). The results were reproducible when the tests were repeated in the same subject. Histologic examination revealed the presence of smooth muscle fibers, between the skeletal fibers of the external anal and urethral sphincters. Evidence suggests that the smooth muscle fibers are the source of the electric activity of the sphincters and might explain some physiologic phenomena such as the external anal contraction on rectal distension or on coughing.
Prasad, Sandip M; Large, Michael C; Patel, Amit R; Famakinwa, Olufenwa; Galocy, R Matthew; Karrison, Theodore; Shalhav, Arieh L; Zagaja, Gregory P
2014-07-01
Retrospective single institution data suggest that postoperative pain after robot-assisted laparoscopic radical prostatectomy is decreased by early removal of the urethral catheter with suprapubic tube drainage. In a randomized patient population we determined whether suprapubic tube drainage with early urethral catheter removal would improve postoperative pain compared with urethral catheter drainage alone. Men with a body mass index of less than 40 kg/m(2) who had newly diagnosed prostate cancer and elected robot-assisted laparoscopic radical prostatectomy were included in analysis. Block randomization by surgeon was used and randomization assignment was done after completing the urethrovesical anastomosis. In patients assigned to suprapubic tube drainage the urethral catheter was removed on postoperative day 1 and all catheters were removed on postoperative day 7. Visual analog pain scale and satisfaction questionnaires were administered on postoperative days 0, 1 and 7. A total of 29 patients were randomized to the urethral catheter vs 29 to the suprapubic tube plus early urethral catheter removal at the time of interim futility analysis. Mean visual analog pain scale scores did not differ between the groups at any time point and a similar percent of patients cited the catheter as the greatest bother with nonsignificant differences in treatment related satisfaction. Complications during postoperative week 1 did not vary between the groups. Based on interim results the trial was terminated due to lack of effect. Patients randomized to suprapubic tube vs urethral catheter drainage for the week after prostatectomy had similar pain, catheter related bother and treatment related satisfaction in the perioperative period. We no longer routinely offer suprapubic tube drainage with early urethral catheter removal at our institution. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Leddy, Laura S.; Vanni, Alex J.; Wessells, Hunter; Voelzke, Bryan B.
2012-01-01
Purpose We examined the success of early endoscopic realignment of pelvic fracture associated urethral injury after blunt pelvic trauma. Materials and Methods A retrospective review was performed of patients with pelvic fracture associated urethral injury who underwent early endoscopic realignment using a retrograde or retrograde/antegrade approach from 2004 to 2010 at a Level 1 trauma center. Followup consisted of uroflowmetry, post-void residual and cystoscopic evaluation. Failure of early endoscopic realignment was defined as patients requiring urethral dilation, direct vision internal urethrotomy, posterior urethroplasty or self-catheterization after initial urethral catheter removal. Results A total of 19 consecutive patients (mean age 38 years) with blunt pelvic fracture associated urethral injury underwent early endoscopic realignment. Twelve cases of complete urethral disruption, 4 of incomplete disruption and 3 of indeterminate status were noted. Mean time to realignment was 2 days and mean duration of urethral catheterization after realignment was 53 days. One patient was lost to followup after early endoscopic realignment. Using an intent to treat analysis early endoscopic realignment failed in 15 of 19 patients (78.9%). Mean time to early endoscopic realignment failure after catheter removal was 79 days. The cases of early endoscopic realignment failure were managed with posterior urethroplasty (8), direct vision internal urethrotomy (3) and direct vision internal urethrotomy followed by posterior urethroplasty (3). Mean followup for the 4 patients considered to have undergone successful early endoscopic realignment was 2.1 years. Conclusions Early endoscopic realignment after blunt pelvic fracture associated urethral injury results in high rates of symptomatic urethral stricture requiring further operative treatment. Close followup after initial catheter removal is warranted, as the mean time to failure after early endoscopic realignment was 79 days in our cohort. PMID:22591965
Mans, Esther; Serra-Prat, Mateu; Palomera, Elisabet; Suñol, Xavier; Clavé, Pere
2015-09-01
The relation between hunger, satiation, and integrated gastrointestinal motility and hormonal responses in morbidly obese patients after sleeve gastrectomy has not been determined. The objective was to assess the effects of sleeve gastrectomy on hunger, satiation, gastric and gallbladder motility, and gastrointestinal hormone response after a liquid meal test. Three groups were studied: morbidly obese patients (n = 16), morbidly obese patients who had had sleeve gastrectomy (n = 8), and nonobese patients (n = 16). The participants fasted for 10 h and then consumed a 200-mL liquid meal (400 kcal + 1.5 g paracetamol). Fasting and postprandial hunger, satiation, hormone concentrations, and gastric and gallbladder emptying were measured several times over 4 h. No differences were observed in hunger and satiation curves between morbidly obese and nonobese groups; however, sleeve gastrectomy patients were less hungry and more satiated than the other groups. Antrum area during fasting in morbidly obese patients was statistically significant larger than in the nonobese and sleeve gastrectomy groups. Gastric emptying was accelerated in the sleeve gastrectomy group compared with the other 2 groups (which had very similar results). Gallbladder emptying was similar in the 3 groups. Sleeve gastrectomy patients showed the lowest ghrelin concentrations and higher early postprandial cholecystokinin and glucagon-like peptide 1 peaks than did the other participants. This group also showed an improved insulin resistance pattern compared with morbidly obese patients. Sleeve gastrectomy seems to be associated with profound changes in gastrointestinal physiology that contribute to reducing hunger and increasing sensations of satiation. These changes include accelerated gastric emptying, enhanced postprandial cholecystokinin and glucagon-like peptide 1 concentrations, and reduced ghrelin release, which together may help patients lose weight and improve their glucose metabolism after surgery. This trial was registered at clinicaltrials.gov as NCT02414893. © 2015 American Society for Nutrition.
General Information about Urethral Cancer
... Treatment Urethral Cancer Treatment (PDQ®)–Patient Version General Information About Urethral Cancer Go to Health Professional Version ... the PDQ Adult Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...
Urethral Cancer Treatment (PDQ®)—Patient Version
Urethral cancer occurs in men and women and can spread quickly to lymph nodes near the urethra. Find out about risk factors, symptoms, tests to diagnose, prognosis, staging, and treatment for urethral cancer.
URETHROPLASTY FOR COMPLICATED ANTERIOR URETHRAL STRICTURES.
Aoki, Katsuya; Hori, Shunta; Morizawa, Yosuke; Nakai, Yasushi; Miyake, Makito; Anai, Satoshi; Torimoto, Kazumasa; Yoneda, Tatsuo; Tanaka, Nobumichi; Yoshida, Katsunori; Fujimoto, Kiyohide
2016-01-01
(Objectives) To compare efficacy and outcome of urethroplasty for complicated anterior urethral strictures. (Methods) Twelve patients, included 3 boys, with anterior urethral stricture underwent urethroplasty after the failure of either urethral dilatation or internal urethrotomy. We evaluated pre- and post-operative Q max and surgical outcome. (Results) Four patients were treated with end-to-end anastomosis, included a case of bulbar urethral elongation simultaneously, one patient was treated with augmented anastomotic urethroplasty, three patients were treated with onlay urethroplasty with prepucial flap, one patient was treated with tubed urethroplasty with prepucial flap (Ducket procedure) and three patients were treated with onlay urethroplasty with buccal mucosal graft. Postoperative Qmax improved in all patients without major complications and recurrence during follow-up periods ranging from 17 to 102 months (mean 55 months). (Conclusions) Urethroplasty is an effective therapeutic procedure for complicated anterior urethral stricture.
Application of dermoscopy image analysis technique in diagnosing urethral condylomata acuminata.
Zhang, Yunjie; Jiang, Shuang; Lin, Hui; Guo, Xiaojuan; Zou, Xianbiao
2018-01-01
In this study, cases with suspected urethral condylomata acuminata were examined by dermoscopy, in order to explore an effective method for clinical. To study the application of dermoscopy image analysis technique in clinical diagnosis of urethral condylomata acuminata. A total of 220 suspected urethral condylomata acuminata were clinically diagnosed first with the naked eyes, and then by using dermoscopy image analysis technique. Afterwards, a comparative analysis was made for the two diagnostic methods. Among the 220 suspected urethral condylomata acuminata, there was a higher positive rate by dermoscopy examination than visual observation. Dermoscopy examination technique is still restricted by its inapplicability in deep urethral orifice and skin wrinkles, and concordance between different clinicians may also vary. Dermoscopy image analysis technique features a high sensitivity, quick and accurate diagnosis and is non-invasive, and we recommend its use.
What matters after sleeve gastrectomy: patient characteristics or surgical technique?
Dhar, Vikrom K; Hanseman, Dennis J; Watkins, Brad M; Paquette, Ian M; Shah, Shimul A; Thompson, Jonathan R
2018-03-01
The impact of operative technique on outcomes in laparoscopic sleeve gastrectomy has been explored previously; however, the relative importance of patient characteristics remains unknown. Our aim was to characterize national variability in operative technique for laparoscopic sleeve gastrectomy and determine whether patient-specific factors are more critical to predicting outcomes. We queried the database of the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program for laparoscopic sleeve gastrostomies performed in 2015 (n = 88,845). Logistic regression models were used to determine predictors of postoperative outcomes. In 2015, >460 variations of laparoscopic sleeve gastrectomy were performed based on combinations of bougie size, distance from the pylorus, use of staple line reinforcement, and oversewing of the staple line. Despite such substantial variability, technique variants were not predictive of outcomes, including perioperative morbidity, leak, or bleeding (all P ≥ .05). Instead, preoperative patient characteristics were found to be more predictive of these outcomes after laparoscopic sleeve gastrectomy. Only history of gastroesophageal disease (odds ratio 1.44, 95% confidence interval 1.08-1.91, P < .01) was associated with leak. Considerable variability exists in technique among surgeons nationally, but patient characteristics are more predictive of adverse outcomes after laparoscopic sleeve gastrectomy. Bundled payments and reimbursement policies should account for patient-specific factors in addition to current accreditation and volume thresholds when deciding risk-adjustment strategies. Copyright © 2018 Elsevier Inc. All rights reserved.
Homopolar machine for reversible energy storage and transfer systems
Stillwagon, Roy E.
1978-01-01
A homopolar machine designed to operate as a generator and motor in reversibly storing and transferring energy between the machine and a magnetic load coil for a thermo-nuclear reactor. The machine rotor comprises hollow thin-walled cylinders or sleeves which form the basis of the system by utilizing substantially all of the rotor mass as a conductor thus making it possible to transfer substantially all the rotor kinetic energy electrically to the load coil in a highly economical and efficient manner. The rotor is divided into multiple separate cylinders or sleeves of modular design, connected in series and arranged to rotate in opposite directions but maintain the supply of current in a single direction to the machine terminals. A stator concentrically disposed around the sleeves consists of a hollow cylinder having a number of excitation coils each located radially outward from the ends of adjacent sleeves. Current collected at an end of each sleeve by sleeve slip rings and brushes is transferred through terminals to the magnetic load coil. Thereafter, electrical energy returned from the coil then flows through the machine which causes the sleeves to motor up to the desired speed in preparation for repetition of the cycle. To eliminate drag on the rotor between current pulses, the brush rigging is designed to lift brushes from all slip rings in the machine.
Homopolar machine for reversible energy storage and transfer systems
Stillwagon, Roy E.
1981-01-01
A homopolar machine designed to operate as a generator and motor in reversibly storing and transferring energy between the machine and a magnetic load coil for a thermo-nuclear reactor. The machine rotor comprises hollow thin-walled cylinders or sleeves which form the basis of the system by utilizing substantially all of the rotor mass as a conductor thus making it possible to transfer substantially all the rotor kinetic energy electrically to the load coil in a highly economical and efficient manner. The rotor is divided into multiple separate cylinders or sleeves of modular design, connected in series and arranged to rotate in opposite directions but maintain the supply of current in a single direction to the machine terminals. A stator concentrically disposed around the sleeves consists of a hollow cylinder having a number of excitation coils each located radially outward from the ends of adjacent sleeves. Current collected at an end of each sleeve by sleeve slip rings and brushes is transferred through terminals to the magnetic load coil. Thereafter, electrical energy returned from the coil then flows through the machine which causes the sleeves to motor up to the desired speed in preparation for repetition of the cycle. To eliminate drag on the rotor between current pulses, the brush rigging is designed to lift brushes from all slip rings in the machine.
2018-05-23
Metastatic Ureteral Neoplasm; Metastatic Urethral Neoplasm; Stage III Bladder Urothelial Carcinoma AJCC v6 and v7; Stage III Ureter Cancer AJCC v7; Stage III Urethral Cancer AJCC v7; Stage IV Bladder Urothelial Carcinoma AJCC v7; Stage IV Ureter Cancer AJCC v7; Stage IV Urethral Cancer AJCC v7; Ureter Urothelial Carcinoma; Urethral Urothelial Carcinoma
Schick, Erik; Bertrand, Pierre E; Jolivet-Tremblay, Martine; Dupont, Charles; Tessier, Jocelyne
2004-01-01
To study the relation between maximum urethral closure pressure (MUCP) at rest and the degree of urethral incompetence in the female. Two hundred fifty five patients aged 20 years or older, with stable bladders on multichannel urodynamics, without known neurological pathology, and with no previous history of pelvic or anti-incontinence surgery were included in the study. Resting urethral pressure profile (UPP) and the grade of urethral incompetence was registered. Mean age of the group was 45.6+/-12.7 years; mean MUCP was 62.7+/-28.5 cm of water. There was a statistically significant difference in the MUCP when the different grades of urethral incompetence were compared to each other, the higher grades being associated with a lower maximal closure pressure. This study demonstrates that there is a highly significant relationship between MUCP and between all grades of urethral incompetence. This supports previous observations that MUCP decreases when abdominal leak point pressure (ALPP) is low and that this might be secondary to some mechanical failure in the pressure transmission from the abdominal cavity to the urethra. Studies should never compare continent to incontinent cohorts without considering their ALPP because in doing so they are comparing groups that are functionally heterogeneous. Copyright 2003 Wiley-Liss, Inc.
Kandpal, D. K.; Rawat, S. K.; Kanwar, S.; Baruha, A.; Chowdhary, S. K.
2013-01-01
Post traumatic urethral injury is uncommon in children. The management of this condition is dependent on the severity of injury. Initial suprapubic cystostomy with delayed repair is the conventional treatment. Successful reconstruction of urethral injury may be followed by urethral stricture, incontinence, impotence, and retrograde ejaculation. Successful repair of post traumatic urethral injury followed by secondary incontinence in children has not been well addressed in literature. We report the management of one such child, with satisfactory outcome with implantation of a new model of single piece artificial urinary sphincter in the bulbar urethra by perineal approach. PMID:24347870
78 FR 17082 - Airworthiness Directives; Rolls-Royce Deutschland Ltd & Co KG Turbojet Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-20
... flight. (5) If you find any broken bolt in the HPT shaft air seal sleeve, visually inspect the HPT stage... assembly, high pressure turbine (HPT) bearing support assembly and HPT air seal sleeve bolts identified... turbine (HPT) bearing support assembly, and HPT air seal sleeve within 100 engine cycles-in-service. (2...
77 FR 66769 - Airworthiness Directives; Rolls-Royce Deutschland Ltd & Co KG Turbojet Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-07
.... (5) If any bolt is found broken in the HPT shaft air seal sleeve, inspect the HPT stage 1 disc for...) bearing support assembly and HPT air seal sleeve bolts identified that, before installation, those bolts... assembly, high-pressure turbine (HPT) bearing support assembly, and HPT air seal sleeve. (2) If engine...
Bergman, Ulf C.
1984-01-01
The safety valve contains a resilient gland to be held between a valve seat and a valve member and is secured to the valve member by a sleeve surrounding the end of the valve member adjacent to the valve seat. The sleeve is movable relative to the valve member through a limited axial distance and a gap exists between said valve member and said sleeve.
Staple line reinforcement during sleeve gastrectomy with a new type of reinforced stapler.
El Moussaoui, Imad; Limbga, Augustin; Mehdi, Abdelilah
2018-04-01
Bleeding and staple-line leak, are the most common complications of laparoscopic sleeve gastrectomy. To decrease the incidence of this complications, a variety of intraoperative reinforcement of staple line is used. Reinforced GIA™ is a new automatic suture device with pre-attached synthetic tissue reinforcement, but no study has evaluated its use in sleeve gastrectomy. The objective of this study is to evaluate the efficacy and safety of this new staple line reinforcement technique in laparoscopic sleeve gastrectomy. We conducted a retrospective review of 290 patients who underwent laparoscopic sleeve gastrectomy between January 2013 and January 2016 in which reinforced GIA™ or standard GIA™ was used. Patients preoperative characteristics, Operative time, staple line leaks, staple line bleeds, stenosis, and complications requiring reoperation were collected. A total of 187 laparoscopic sleeve gastrectomy were performed with standard GIA and 103 with reinforced GIA™. Patient characteristics were not significantly different between the groups. The average operating time in the standard GIA group is 57.41±16.44 min against 50.9±14.12 min in the reinforced GIA group (P=0.006). Two staple line leaks developed in the standard GIA group and reoperated against no patients in the reinforced GIA group, without significant difference between the both groups (P=0.66). Staple line bleeds are less in the reinforced GIA group, only 23 (22.3%) against 78 (41.7%) cases in the standard GIA group (P=0.001). No patients of both groups developed gastric sleeve stenosis. During laparoscopic sleeve gastrectomy, the use of a reinforced stapler significantly reduces the operative time and staple line bleeding. No significant difference is evidenced in terms of reduction of staple line leaks with this reinforced stapler.
Method and apparatus for extracting tritium and preparing radioactive waste for disposal
Heung, L.K.
1994-03-29
Apparatus is described for heating an object such as a nuclear target bundle to release and recover hydrogen and contain the disposable residue for disposal. The apparatus comprises an inverted furnace, a sleeve/crucible assembly for holding and enclosing the bundle, conveying equipment for placing the sleeve onto the crucible and loading the bundle into the sleeve/crucible, a lift for raising the enclosed bundle into the furnace, and hydrogen recovery equipment including a trap and strippers, all housed in a containment having negative internal pressure. The crucible/sleeve assembly has an internal volume that is sufficient to enclose and hold the bundle before heating; the crucible's internal volume is sufficient by itself to hold and enclose the bundle's volume after heating. The crucible can then be covered and disposed of; the sleeve, on the other hand, can be reused. 4 figures.
Development of on line automatic separation device for apple and sleeve
NASA Astrophysics Data System (ADS)
Xin, Dengke; Ning, Duo; Wang, Kangle; Han, Yuhang
2018-04-01
Based on STM32F407 single chip microcomputer as control core, automatic separation device of fruit sleeve is designed. This design consists of hardware and software. In hardware, it includes mechanical tooth separator and three degree of freedom manipulator, as well as industrial control computer, image data acquisition card, end effector and other structures. The software system is based on Visual C++ development environment, to achieve localization and recognition of fruit sleeve with the technology of image processing and machine vision, drive manipulator of foam net sets of capture, transfer, the designated position task. Test shows: The automatic separation device of the fruit sleeve has the advantages of quick response speed and high separation success rate, and can realize separation of the apple and plastic foam sleeve, and lays the foundation for further studying and realizing the application of the enterprise production line.
Iatrogenic injury of the intrathoracic oesophagus with bougie during sleeve gastrectomy
Signorini, Franco José; Verónica, Gorodner; Marcos, Marani; German, Viscido; Federico, Moser
2018-01-01
One of the most popular procedures amongst obesity surgery is the sleeve gastrectomy. There is international consensus regarding the usage of bougie for sleeve gastrectomy calibration. Nevertheless, there is a dissociation between the number of oesophageal perforations reported for any other oesophageal/gastric operation that requires bougie (e.g., anti-reflux surgery, incidence 1.2%) and bariatric surgery, where this complication seems to be almost a myth. Interestingly enough, the number of bariatric procedures is much higher than any other oesophageal/gastric surgery. This suggests that oesophageal perforations in obesity surgery are underreported. We report a case of injury of the intrathoracic oesophagus with bougie that occurred during a sleeve gastrectomy. In the infrequent case that the perforation is diagnosed during surgery, primary repair during the same intervention is highly recommended. Videothoracoscopy might be an effective option in case of necessity. We were able to complete the sleeve gastrectomy without increasing morbidity. PMID:28695879
NASA Technical Reports Server (NTRS)
Burgess, Kevin (Inventor); Yakos, David (Inventor); Walthall, Bryan (Inventor)
2012-01-01
A stemless ball valve comprising: a right flange; left flange; ball with an axis pin and two travel pins; ball seal on either side of the ball; guide sleeve with inner walls comprising two channels; cartridge guide holder; inner magnetic cartridge; and outer magnetic cartridge. The ball is situated inside of the guide sleeve, and a travel pin is located in each of the two channels. The guide sleeve is situated inside of the cartridge guide holder, which is located adjacent to and outside of the inner magnetic cartridge and secured to the inner magnetic cartridge such that when the inner magnetic cartridge rotates, the cartridge guide holder also rotates. The cartridge guide holder is secured to the guide sleeve such that when the cartridge guide holder rotates, the travel pins move within the channels in the inner walls of the guide sleeve, thereby causing the ball to rotate.
Primary urethral reconstruction results in penile fracture.
Barros, R; Silva, Mis; Antonucci, V; Schulze, L; Koifman, L; Favorito, L A
2018-01-01
Objective This study assessed primary urethral reconstruction results in patients with a penile fracture. Materials and methods Between January 2005 and April 2016, patients who underwent primary urethral reconstruction due to penile fracture were called for a follow-up. Epidemiological and clinical presentation data and operative findings were reviewed retrospectively. Partial urethral lesions were primarily treated with interrupted absorbable sutures over urethral catheter. In cases of complete urethral lesion, tension-free end-to-end anastomosis was performed. From the third month after surgery, all patients were interviewed using the International Prostate Symptom Score questionnaire and uroflowmetry. Retrograde urethrocystography was used in patients with urinary symptoms or altered uroflowmetry to rule out or confirm urethral stenosis. Results Of 175 patients with penile fractures, 27 (15.4%) had associated urethral injury. All patients were diagnosed with penile fracture by means of clinical history and physical examination. No subsequent examinations were conducted. Ages varied from 30 years to 58 years old (mean 39.2 years). All fractures resulted from sexual activity. Reported sexual positions were 'doggy style' position in eight cases (61.5%) and with the 'man on top' in five cases (38.4%). Ten patients (76.9%) experienced haematuria, ten (76.9%) had urethral bleeding and four (30.7%) suffered urinary retention. Unilateral and bilateral injury of the corpus cavernosum was observed in four (30.7%) and nine (69.2%) patients, respectively; partial injury was found in nine cases (69.3%) and complete urethral injury was noticed in four cases (30.7%). All cases of complete urethral injury were associated with bilateral lesion of the corpus cavernosum. Six patients who had uroflowmetry with maximum urinary flow rate below 15 ml/s and/or had IPSS above 7 underwent retrograde urethrocystogram, and this was normal in all cases, excluding the possibility of urethral stenosis. Two patients (15.3%) experienced surgical postoperative complications represented by an urethrocutaneous fistula and a subcutaneous abscess adjacent to the end-to-end anastomosis area. Conclusions Penile fracture is a rare urological emergency, especially when it is associated with a urethral lesion. This must be suspected when the clinical picture is suggestive or in cases of high-energy trauma, especially in bilateral lesions of the corpus cavernosum. Complementary imaging methods are not needed in these cases and immediate exploration should not be delayed. Primary urethroplasty produces satisfactory results with low complication levels. Nonetheless, prospective studies with larger samples should be conducted.
Micromachined fiber optic Fabry-Perot underwater acoustic probe
NASA Astrophysics Data System (ADS)
Wang, Fuyin; Shao, Zhengzheng; Hu, Zhengliang; Luo, Hong; Xie, Jiehui; Hu, Yongming
2014-08-01
One of the most important branches in the development trend of the traditional fiber optic physical sensor is the miniaturization of sensor structure. Miniature fiber optic sensor can realize point measurement, and then to develop sensor networks to achieve quasi-distributed or distributed sensing as well as line measurement to area monitoring, which will greatly extend the application area of fiber optic sensors. The development of MEMS technology brings a light path to address the problems brought by the procedure of sensor miniaturization. Sensors manufactured by MEMS technology possess the advantages of small volume, light weight, easy fabricated and low cost. In this paper, a fiber optic extrinsic Fabry-Perot interferometric underwater acoustic probe utilizing micromachined diaphragm collaborated with fiber optic technology and MEMS technology has been designed and implemented to actualize underwater acoustic sensing. Diaphragm with central embossment, where the embossment is used to anti-hydrostatic pressure which would largely deflect the diaphragm that induce interferometric fringe fading, has been made by double-sided etching of silicon on insulator. By bonding the acoustic-sensitive diaphragm as well as a cleaved fiber end in ferrule with an outer sleeve, an extrinsic Fabry-Perot interferometer has been constructed. The sensor has been interrogated by quadrature-point control method and tested in field-stable acoustic standing wave tube. Results have been shown that the recovered signal detected by the sensor coincided well with the corresponding transmitted signal and the sensitivity response was flat in frequency range from 10 Hz to 2kHz with the value about -154.6 dB re. 1/μPa. It has been manifest that the designed sensor could be used as an underwater acoustic probe.
TRENDS IN STRICTURE MANAGEMENT AMONG MALE MEDICARE BENEFICIARIES: UNDERUSE OF URETHROPLASTY?
Anger, Jennifer T.; Buckley, Jill C.; Santucci, Richard A.; Elliott, Sean P.; Saigal, Christopher S.
2012-01-01
Objectives We sought to analyze trends in male urethral stricture management through the use of 1992–2001 Medicare claims data, and to determine whether certain racial and ethnic groups bear a disproportionate burden of urethral stricture disease. Methods We analyzed Medicare claims for fiscal years 1992, 1995, 1998, and 2001. ICD-9 diagnosis codes were used to identify men with urethral stricture. Demographic characteristics assessed included patient age, race, and comorbidities as measured by the Charlson index. Treatments were identified by CPT-4 procedure codes and stratified into four treatment types: (1) urethral dilation, (2) direct vision internal urethrotomy (DVIU), (3) urethral stent/steroid injection, and (4) urethroplasty. Results Overall rates of stricture diagnosis decreased from 10,088 per 100,000 population in 1992 to 6,897 in 2001 (1.4% to 0.9%). Stricture prevalence was highest among African American and Hispanic men, although urethroplasty rates were highest among Caucasians. DVIU was the most common treatment, followed by urethral dilation, urethral stent/steroid injection, and urethroplasty. Urethroplasty rates remained stable, but quite low (0.6–0.8%), over the period of study. Conclusions Overall rates of stricture diagnosis decreased from 1992 to 2001. Despite the poor overall efficacy of urethrotomy and urethral dilation relative to urethroplasty, and despite the known complications of stent placement in this setting, urethroplasty rates were the lowest of all treatments. Although we cannot determine treatment success with these data, these findings suggest an underuse of the most efficacious treatment for urethral stricture disease, urethroplasty. PMID:21168194
Linder, Brian J; Viers, Boyd R; Ziegelmann, Matthew J; Rivera, Marcelino E; Elliott, Daniel S
2017-01-01
To compare outcomes for single urethral cuff downsizing versus tandem cuff placement during artificial urinary sphincter (AUS) revision for urethral atrophy. We identified 1778 AUS surgeries performed at our institution from 1990-2014. Of these, 406 were first AUS revisions, including 69 revisions for urethral atrophy. Multiple clinical and surgical variables were evaluated for potential association with device outcomes following revision, including surgical revision strategy (downsizing a single urethral cuff versus placing tandem urethral cuffs). Of the 69 revision surgeries for urethral atrophy at our institution, 56 (82%) were tandem cuff placements, 12 (18%) were single cuff downsizings and one was relocation of a single cuff. When comparing tandem cuff placements and single cuff downsizings, the cohorts were similar with regard to age (p=0.98), body-mass index (p=0.95), prior pelvic radiation exposure (p=0.73) and length of follow-up (p=0.12). Notably, there was no difference in 3-year overall device survival compared between single cuff and tandem cuff revisions (60% versus 76%, p=0.94). Likewise, no significant difference was identified for tandem cuff placement (ref. single cuff) when evaluating the risk of any tertiary surgery (HR 0.95, 95% CI 0.32-4.12, p=0.94) or urethral erosion/device infection following revision (HR 0.79, 95% CI 0.20-5.22, p=0.77). There was no significant difference in overall device survival in patients undergoing single cuff downsizing or tandem cuff placement during AUS revision for urethral atrophy. Copyright® by the International Brazilian Journal of Urology.
Effect of early realignment on length and delayed repair of postpelvic fracture urethral injury.
Koraitim, Mamdouh M
2012-04-01
To determine the effect of early realignment of posterior urethral injury on the length and delayed repair of ensuing urethral defect. We reviewed the medical records of 120 patients with a pelvic fracture urethral defect who were referred for delayed repair from elsewhere from 1995 to 2009. The review was focused on 5 variables: initial management of urethral injury, length of urethral defect, type of delayed repair, continence, and erectile function. Of the patients, 26 were excluded from the study and 94 were categorized as having been initially treated by realignment (42 patients, group 1) or suprapubic cystostomy (52 patients, group 2). Urethral defects ≤ 2 cm in length were found in 28 patients (67%) in group 1 versus 22 (42%) in group 2. Defects >2 cm were found in 14 patients (33%) in group 1 versus 30 (58%) in group 2. The repair was accomplished by a simple perineal operation in 32 (76%) and 30 (58%) patients in groups 1 and 2, respectively. An elaborated perineal or perineo-abdominal procedure was required in 10 (24%) and 22 (42%) patients in groups 1 and 2, respectively (all P < .05). Incontinence occurred in 1 patient in group 1. Impotence developed in 10 (28%) of 36 realigned adults and in 2 (5%) of 38 adults with suprapubic cystostomy. Early realignment of posterior urethral injury decreases the length of the ensuing urethral defect and facilitates its delayed repair. Incontinence and impotence appear to result from the injury itself and not the treatment. Copyright © 2012 Elsevier Inc. All rights reserved.
QUICK DISCONNECT ELECTRICAL CONNECTOR
None
1962-08-14
A remotely actuated quick-dlsconnect electrical connector which comprises a pair of mating portrons releasably retained together by a bayonet- type joint with a rotatable sleeve on one of the mating portions providing for engagement and disengagement of the joint is described. A lanyard with ends passed through fulcrums and affixed to the sleeve erfects rotation of the sleeve and disengages the joint. (AEC)
Correy, T.B.
1961-10-01
A welding torch into which water and inert gas are piped separately for cooling and for providing a suitable gaseous atmosphere is described. A welding electrode is clamped in the torch by a removable collet sleeve and a removable collet head. Replacement of the sleeve and head with larger or smaller sleeve and head permits a larger or smaller welding electrode to be substituted on the torch. (AEC)
Directly susceptible, noncarbon metal ceramic composite crucible
Holcombe, Jr., Cressie E.; Kiggans, Jr., James O.; Morrow, S. Marvin; Rexford, Donald
1999-01-01
A sintered metal ceramic crucible suitable for high temperature induction melting of reactive metals without appreciable carbon or silicon contamination of the melt. The crucible comprises a cast matrix of a thermally conductive ceramic material; a perforated metal sleeve, which serves as a susceptor for induction heating of the crucible, embedded within the ceramic cast matrix; and a thermal-shock-absorber barrier interposed between the metal sleeve and the ceramic cast matrix to allow for differential thermal expansions between the matrix and the metal sleeve and to act as a thermal-shock-absorber which moderates the effects of rapid changes of sleeve temperature on the matrix.
Hutto, E.L.
1961-08-15
A manipulator is described for performing, within an entirely enclosed cell containling radioactive materials, various mechanical operations. A rod with flexible fingers is encompassed by a tubular sleeve shorter than the rod. Relative movement between the rod and sleeve causes the fingers to open and close. This relative movement is effected by relative movement of permanent magnets in magnetic coupling relation to magnetic followers affixed to the ends of the rod and sleeve. The rod and its sleeve may be moved as a unit axially or may be rotated by means of the magnetic couplings. The manipulator is enclosed within a tubular member which is flexibly sealed to an opening in the cell. (AEC)
Li, Shuben; Chai, Huiping; Huang, Jun; Zeng, Guangqiao; Shao, Wenlong; He, Jianxing
2014-04-01
The purpose of the current study is to present the clinical and surgical results in patients who underwent hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection. Thirty-one patients, 27 men and 4 women, underwent segmental-main bronchial sleeve anastomoses for non-small cell lung cancer between May 2004 and May 2011. Twenty-six (83.9%) patients had squamous cell carcinoma, and 5 patients had adenocarcinoma. Six patients were at stage IIB, 24 patients at stage IIIA, and 1 patient at stage IIIB. Secondary sleeve anastomosis was performed in 18 patients, and Y-shaped multiple sleeve anastomosis was performed in 8 patients. Single segmental bronchiole anastomosis was performed in 5 cases. The average time for chest tube removal was 5.6 days. The average length of hospital stay was 11.8 days. No anastomosis fistula developed in any of the patients. The 1-, 2-, and 3-year survival rates were 83.9%, 71.0%, and 41.9%, respectively. Hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection is a complex technique that requires training and experience, but it is an effective and safe operation for selected patients.
Gesture-Based Robot Control with Variable Autonomy from the JPL Biosleeve
NASA Technical Reports Server (NTRS)
Wolf, Michael T.; Assad, Christopher; Vernacchia, Matthew T.; Fromm, Joshua; Jethani, Henna L.
2013-01-01
This paper presents a new gesture-based human interface for natural robot control. Detailed activity of the user's hand and arm is acquired via a novel device, called the BioSleeve, which packages dry-contact surface electromyography (EMG) and an inertial measurement unit (IMU) into a sleeve worn on the forearm. The BioSleeve's accompanying algorithms can reliably decode as many as sixteen discrete hand gestures and estimate the continuous orientation of the forearm. These gestures and positions are mapped to robot commands that, to varying degrees, integrate with the robot's perception of its environment and its ability to complete tasks autonomously. This flexible approach enables, for example, supervisory point-to-goal commands, virtual joystick for guarded teleoperation, and high degree of freedom mimicked manipulation, all from a single device. The BioSleeve is meant for portable field use; unlike other gesture recognition systems, use of the BioSleeve for robot control is invariant to lighting conditions, occlusions, and the human-robot spatial relationship and does not encumber the user's hands. The BioSleeve control approach has been implemented on three robot types, and we present proof-of-principle demonstrations with mobile ground robots, manipulation robots, and prosthetic hands.
Sorafenib in Treating Patients With Regional or Metastatic Cancer of the Urothelium
2014-05-20
Adenocarcinoma of the Bladder; Distal Urethral Cancer; Metastatic Transitional Cell Cancer of the Renal Pelvis and Ureter; Proximal Urethral Cancer; Recurrent Bladder Cancer; Recurrent Transitional Cell Cancer of the Renal Pelvis and Ureter; Recurrent Urethral Cancer; Regional Transitional Cell Cancer of the Renal Pelvis and Ureter; Squamous Cell Carcinoma of the Bladder; Stage III Bladder Cancer; Stage IV Bladder Cancer; Transitional Cell Carcinoma of the Bladder; Urethral Cancer Associated With Invasive Bladder Cancer
Krishnamurthi, V; Spirnak, J P
1995-02-01
Urethral obliteration is an uncommon complication of urethral injury and is usually associated with pelvic fracture. Until recently, surgical reconstruction was the only means available to restore urethral continuity. Although formal urethroplasty may be associated with excellent success rates, impotence and incontinence are potential complications. Endoscopic urethroplasty has recently evolved into a suitable alternative to surgical reconstruction in selected cases. We review here the technique of endoscopic urethroplasty and include our initial results.
Kirschner-Hermanns, Ruth; Anding, Ralf; Rosier, Peter; Birder, Lori; Andersson, Karl Erik; Djurhuus, Jens Christian
2016-02-01
Urethral pathophysiology is often neglected in discussions of bladder dysfunction. It has been debated whether "urethral sphincter instability," referred to based on observed "urethral pressure variations," is an important aspect of overactive bladder syndrome (OAB). The purpose of this report is to summarize current urethral pathophysiology evidence and outline directions for future research based on a literature review and discussions during the ICI-RS meeting in Bristol in 2014. Urethral pathophysiology with a focus on urethral pressure variation (UPV) was presented and discussed in a multidisciplinary think tank session at the ICI_R meeting in Bristol 2014. This think tank session was based on collaboration between physicians and basic science researchers. Experimental animal studies or studies performed in clinical series (predominantly symptomatic women) provided insights into UPV, but the findings were inconsistent and incomplete. However, UPV is certainly associated with lower urinary tract symptoms (likely OAB), and thus, future research on this topic is relevant. Future research based on adequately defined clinical (and urodynamic) parameters with precisely defined patient groups might shed better light on the cause of OAB symptoms. Further fundamental investigation of urethral epithelial-neural interactions via the release of mediators should enhance our knowledge and improve the management of patients with OAB. © 2016 The Authors. Neurourology and Urodynamics published by Wiley Periodicals, Inc.
[Reconstructive treatment of female urethral estenosis secondary to erosion by suburethral tape].
Angulo, J C; Mateo, E; Lista, F; Andrés, G
2011-04-01
Female urethral stricture secondary to erosión by suburethral sling is an unfrequent problem of difficult solution. Ventral vaginal rotation flaps or buccal mucosa dorsal grafts are not useful because this type of stricture is very proximal (close to the bladder neck) and the vagina is thinned. We present our experience to manage this problem using excision of disease urethral tract, associated to bladder mucosa flap and vaginal sling using transverse vaginal flap to repair the weakened vaginal wall. Three females with urethral stricture secondary to urethral erosion of their sling were treated with a technique of combined urethroplasty with bladder flap and vaginal reinforcement with pediculated vaginal flap transferred in a mini-sling fashion. Two of the patients suffered chronic urinary retention and preoperative placement of urethral catheter was not possible. The patients were evaluated 12, 36 and 55 months after surgery, respectively. Surgery was performed without complications. Results were satisfactory in all the patients, reaching good micturition postoperative caliber and being without incontinence at follow-up. Patients with suburethral erosion by a synthetic sling and secondary severe urethral stricture need total extirpation of the mesh and complete reconstruction of the urethro-vaginal septum. Tension-free urethral suture and use of vaginal sling with the technique here described are two useful technical tips for this problem. Copyright © 2011 AEU. Published by Elsevier Espana. All rights reserved.
Kaijser, Mirjam A; van Ramshorst, Gabrielle H; Emous, Marloes; Veeger, Nic J G M; van Wagensveld, Bart A; Pierie, Jean-Pierre E N
2018-04-09
Bariatric procedures are technically complex and skill demanding. In order to standardize the procedures for research and training, a Delphi analysis was performed to reach consensus on the practice of the laparoscopic gastric bypass and sleeve gastrectomy in the Netherlands. After a pre-round identifying all possible steps from literature and expert opinion within our study group, questionnaires were send to 68 registered Dutch bariatric surgeons, with 73 steps for bypass surgery and 51 steps for sleeve gastrectomy. Statistical analysis was performed to identify steps with and without consensus. This process was repeated to reach consensus of all necessary steps. Thirty-eight participants (56%) responded in the first round and 32 participants (47%) in the second round. After the first Delphi round, 19 steps for gastric bypass (26%) and 14 for sleeve gastrectomy (27%) gained full consensus. After the second round, an additional amount of 10 and 12 sub-steps was confirmed as key steps, respectively. Thirteen steps in the gastric bypass and seven in the gastric sleeve were deemed advisable. Our expert panel showed a high level of consensus expressed in a Cronbach's alpha of 0.82 for the gastric bypass and 0.87 for the sleeve gastrectomy. The Delphi consensus defined 29 steps for gastric bypass and 26 for sleeve gastrectomy as being crucial for correct performance of these procedures to the standards of our expert panel. These results offer a clear framework for the technical execution of these procedures.
Computational Modeling and Simulation of Genital Tubercle Development
Hypospadias is a developmental defect of urethral tube closure that has a complex etiology. Here, we describe a multicellular agent-based model of genital tubercle development that simulates urethrogenesis from the urethral plate stage to urethral tube closure in differentiating ...
DeLancey, John O. L.; Miller, Janis M.; Kearney, Rohna; Howard, Denise; Reddy, Pranathi; Umek, Wolfgang; Guire, Kenneth E.; Margulies, Rebecca U.; Ashton-Miller, James A.
2009-01-01
Background Vaginal birth increases the chance a woman will develop stress incontinence. This study evaluates the relative contributions of urethral mobility and urethral function to stress incontinence. Methods This is a case-control study with group matching. Eighty primiparous women with self-reported new stress incontinence 9–12 months postpartum were compared to 80 primiparous continent controls to identify impairments specific to stress incontinence. Eighty nulliparous continent controls were evaluated as a comparison group to allow us to determine birth-related changes not associated with stress incontinence. Urethral function was measured with urethral profilometry, and vesical neck mobility was assessed with ultrasound and Q-tip test. Urethral sphincter anatomy and mobility were evaluated using MRI. The association between urethral closure pressure, vesical neck movement, and incontinence were explored using logistic regression. Results Urethral closure pressure in primiparous incontinent women (62.9 +/− 25.2 s.d. cm H20) was lower than in primiparous continent women (83.0 +/− 21.0, p<0.001; effect size d= 0.91) who were similar to nulliparous women (90.3 +/− 25.0, p=0.09). Vesical neck movement measured during cough with ultrasound was the mobility parameter most associated with stress incontinence; 15.6 +/− 6.2 mm in incontinent women versus 10.9 +/− 6.2 in primiparous continent women (p < 0.0001, d = 0.75) or nulliparas (9.9 +/− 5.0, p=0.33). Logistic regression disclosed the two-variable model (max-rescaled R2 =0.37, p < 0.0001) was more strongly associated with stress incontinence than either single variable models, urethral closure pressure (R2 = 0.25, p <0.0001) or vesical neck movement (R2 = 0.16 p < 0.0001). Conclusions Lower maximal urethral closure pressure is the parameter most associated with de novo stress incontinence after first vaginal birth followed by vesical neck mobility. PMID:17666611
Factors affecting urine EIA sensitivity in the detection of Chlamydia trachomatis in men.
Talbot, H; Romanowski, B
1994-01-01
OBJECTIVE--This study examined the effects of four variables on the detection of Chlamydia trachomatis in urine from men by enzyme immunoassay (EIA). These variables were: symptoms and signs of urethritis, urine polymorphonuclear leucocytes (PMN), inclusion counts from urethral chlamydia cell cultures and the time between testing and last voiding. METHODS--Included were patients with and without symptoms and/or signs of urethritis attending the Edmonton Sexually Transmitted Disease Clinic. Men were asked to submit a 20 ml volume urine sample. Urethral swabs were collected for gram stain, chlamydia and gonorrhea culture. RESULTS--A total of 318 men were evaluated of whom 47 had chlamydia. Excluding six men who were coinfected with gonorrhoea, sensitivities and specificities of the Microtrak, Chlamydiazyme and IDEIA systems were 78.1% and 99.6%, 75.6% and 100%, and 80.5% and 97.8% respectively. Last void time did not affect the sensitivity. However, sensitivity was best when applied to men with severe evidence of urethritis. CONCLUSION--There is evidence that urine EIA could be used to detect chlamydia in men with acute urethritis but not in those without signs of urethritis. PMID:8206466
Melman, Arnold; Tar, Moses; Boczko, Judd; Christ, George; Leung, Albert C; Zhao, Weixin; Russell, Robert G
2005-11-01
To perform a comparison to determine which of two methods of partial urethral ligation produces the most consistent outcome and fewest side effects. Such a study has not been previously reported. Partial urethral ligation is a means of causing reproducible bladder outlet obstruction. In the male rat model, partial urethral obstruction can be performed either by perineal incision and bulbous urethral ligation or retropubic incision and midprostatic obstruction. Fifteen male Sprague-Dawley rats were studied. Five were selected for bulbous urethral obstruction through a perineal incision, five for midprostatic obstruction using a retropubic approach, and five for a sham operation through a perineal incision. The operative time was shorter and morbidity lower with the perineal approach compared with the retropubic approach. Inflammation or infection, or both, were seen in the prostate, bladder, proximal urethra, ureters, and kidneys in the rats in which a midprostatic obstruction was performed. The proximal urethra and prostate were mildly inflamed in those rats that underwent bulbous obstruction. Sham-operated rats exhibited mild prostatitis only. The perineal approach to the bulbous urethra is the method of choice for creating a partial urethral obstruction model of bladder outlet obstruction in the male rat.
Advances in urethral stricture management
Gallegos, Maxx A.; Santucci, Richard A.
2016-01-01
Urethral stricture/stenosis is a narrowing of the urethral lumen. These conditions greatly impact the health and quality of life of patients. Management of urethral strictures/stenosis is complex and requires careful evaluation. The treatment options for urethral stricture vary in their success rates. Urethral dilation and internal urethrotomy are the most commonly performed procedures but carry the lowest chance for long-term success (0–9%). Urethroplasty has a much higher chance of success (85–90%) and is considered the gold-standard treatment. The most common urethroplasty techniques are excision and primary anastomosis and graft onlay urethroplasty. Anastomotic urethroplasty and graft urethroplasty have similar long-term success rates, although long-term data have yet to confirm equal efficacy. Anastomotic urethroplasty may have higher rates of sexual dysfunction. Posterior urethral stenosis is typically caused by previous urologic surgery. It is treated endoscopically with radial incisions. The use of mitomycin C may decrease recurrence. An exciting area of research is tissue engineering and scar modulation to augment stricture treatment. These include the use of acellular matrices or tissue-engineered buccal mucosa to produce grafting material for urethroplasty. Other experimental strategies aim to prevent scar formation altogether. PMID:28105329
The urethral pressure profiles in continent and stress-incontinent women.
Henriksson, L; Andersson, K E; Ulmsten, U
1979-01-01
Simultaneous urethrocystometry, including recording of the urethral pressure profile, was performed in 127 women aged 30 to 69 years; 42 of the women were free from urologic disorders and 85 had stress incontinence of urine. Both groups were subgrouped according to age. The results in the continent and the incontinent women were analyzed separately, in order to disclose any age-related changes. The data within each decade of age were also comparatively analyzed. In the bladder pressure at rest no age-related changes were found, and the readings were similar in the continent and the incontinent women. The maximum urethral pressure fell significantly with rising age in both groups and was significantly reduced in stress incontinence. The urethral closure pressure showed variations similar to those in the maximum urethral pressure. No lower limit of urethral closure pressure that definitely predisposed to stress incontinence could be established. The functional length of the urethra diminished significantly with rising age in the continent, but not in the incontinent women. The absolute length of the urethra did not show such diminution. Both the functional and the absolute urethral length were significantly less in the incontinent than in the continent women in the age groups between 30 and 49 years.
Does Sleeve Shape Make a Difference in Outcomes?
Alhaj Saleh, Adel; Janik, Michal R; Mustafa, Rami R; Alshehri, Mohammed; Khan, Adil H; Kalantar Motamedi, Seyed Mohammad; Rahim, Shiraz; Patel, Indravadan; Aryaie, Amir; Abbas, Mujjahid; Rogula, Tomasz; Khaitan, Leena
2018-06-01
Sleeve gastrectomy (SG) is one of the most common procedures performed for weight loss. Many seek the "perfect sleeve" with the notion that the type of calibrating device affects sleeve shape, and this in turn will affect outcomes and complications. Two major concerns after SG are amount of weight loss and acid reflux. Our aim was to determine if the various calibration methods could impact sleeve shape and thereby allow for better outcomes of weight loss and reflux. A retrospective chart review was performed of 210 patients who underwent SG and had postoperative upper gastrointestinal (UGI) study from 2011 to 2015 in a single center by a single (fellowship-trained) bariatric surgeon. Data regarding demographics, calibrating devices and clinical outcomes at 1 year (weight loss and de novo acid reflux) were collected. UGIs were reviewed by two radiologists blinded to the clinical outcomes. Sleeve shape was classified according to a previously described classification as tubular, dumbbell, upper pouch, or lower pouch. The types of calibrating devices used to guide the sleeve size intraoperatively were endoscopy, large-bore orogastric tube, and fenestrated suction tube. One hundred ninety-nine patients met inclusion criteria (11 had no esophagram). Demographics revealed age 45.76 ± 10.6 years, BMI 47 ± 8.6 kg/m 2 , and 82% female. Calibration devices used were endoscopic guidance (7.6%), large bore orogastric tube (41.4%), and fenestrated suction tube (50.5%). Sleeve shape was reported as 32.6% tubular, 20.6% dumbbell, 39.2% lower pouch, and 7.5% upper pouch (100% interrater reliability). No correlation was seen with type of calibration used. Of patients, 62.0% had > 50% excess weight loss at 1 year. Twenty-three percent of patients remained on PPI at 1 year (of which 43.3% did not have reflux preoperatively). The lower pouch shape showed a trend toward less reflux and more weight loss. This study showed no clear association between uniformity of sleeve shape and the type of calibration device used. The study showed a trend toward decreased reflux and improved weight loss with the lower pouch shape, regardless of calibration device.
Characterization and Surgical Management of Achilles Tendon Sleeve Avulsions.
Huh, Jeannie; Easley, Mark E; Nunley, James A
2016-06-01
An Achilles sleeve avulsion occurs when the tendon ruptures distally from its calcaneal insertion as a continuous "sleeve." This relatively rare injury pattern may not be appreciated until the time of surgery and can be challenging to treat because, unlike a midsubstance rupture, insufficient tendon remains on the calcaneus to allow for end-to-end repair, and unlike a tuberosity avulsion fracture, any bony element avulsed with the tendon is inadequate for internal fixation. This study aimed to highlight the characteristics of Achilles sleeve avulsions and present the outcomes of operative repair using suture anchor fixation. A retrospective analysis was conducted on 11 consecutive Achilles tendon sleeve avulsions (10 males, 1 female; mean age 44 years) that underwent operative repair between 2008 and 2014. Patient demographics, injury presentation, and operative details were reviewed. Postoperative outcomes were collected at a mean follow-up of 38.4 (range, 12-83.5) months, including the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot score, visual analog scale (VAS) for pain, plantarflexion strength, patient satisfaction, and complications. Eight patients (72.7%) had preexisting symptoms of insertional Achilles disease. Ten of 11 (90.9%) injuries were sustained during recreational athletic activity. An Achilles sleeve avulsion was recognized preoperatively in 7 of 11 (64%) cases, where lateral ankle radiographs demonstrated a small radiodensity several centimeters proximal to the calcaneal insertion. Intraoperatively, 90.9% of sleeve avulsions had a concomitant Haglund deformity and macroscopic evidence of insertional tendinopathy. All patients healed after suture anchor repair. The average AOFAS score was 92.8 and VAS score was 0.9. Ten patients (90.9%) were completely satisfied. One complication occurred, consisting of delayed wound healing. Achilles tendon sleeve avulsions predominantly occurred in middle-aged men with preexisting insertional disease, while engaged in athletic activity. Suture anchor fixation, combined with addressing concomitant insertional pathology, was a reliable and safe technique for the operative management of Achilles tendon sleeve avulsions. The majority of patients returned to their preinjury levels of work and recreational activity. Level IV, retrospective case series. © The Author(s) 2016.
Use of overlapping buccal mucosa graft urethroplasty for complex anterior urethral strictures
2015-01-01
Complex anterior urethral stricture disease typically manifests as a symptomatic, severely narrowed, long stricture (or multiple strictures) in which conventional excision and/or augmentation is not feasible. Overlapping buccal mucosal graft urethroplasty (OBMGU) is an innovative hybrid technique, combining the well-established principles of dorsal and ventral graft augmentation to allow single stage reconstruction of complex anterior urethral strictures. In this review, we discuss the rationale, techniques, and outcomes of OBMGU for complex anterior urethral strictures. PMID:26813234
Jordan, Stephen J; Schwebke, Jane R; Aaron, Kristal J; Van Der Pol, Barbara; Hook, Edward W
2017-07-01
Urethral swabs are the samples of choice for point-of-care Gram stain testing to diagnose Neisseria gonorrhoeae infection and nongonococcal urethritis (NGU) in men. As an alternative to urethral swabs, meatal swabs have been recommended for the collection of urethral discharge to diagnose N. gonorrhoeae and Chlamydia trachomatis infection in certain populations by nucleic acid amplification testing (NAAT), as they involve a less invasive collection method. However, as meatal swabs could be sampling a reduced surface area and result in fewer collected epithelial cells compared to urethral swabs, the adequacy of meatal swab specimens to collect sufficient cellular material for Gram stain testing remains unknown. We enrolled 66 men who underwent either urethral or meatal swabbing and compared the cellular content and Gram stain failure rate. We measured the difference in swab cellular content using the Cepheid Xpert CT/NG sample adequacy control crossing threshold (SAC CT ) and determined the failure rate of Gram stain smears (GSS) due to insufficient cellular material. In the absence of discharge, meatal smears were associated with a significant reduction in cellular content ( P = 0.0118), which corresponded with a GSS failure rate significantly higher than that for urethral swabs (45% versus 3%, respectively; P < 0.0001). When discharge was present, there was no difference among results from urethral and meatal swabs. Therefore, if GSS testing is being considered for point-of-care diagnosis of N. gonorrhoeae infection or NGU in men, meatal swabs should be avoided in the absence of a visible discharge. Copyright © 2017 American Society for Microbiology.
AT1 expression in human urethral stricture tissue.
Siregar, Safendra; Parardya, Aga; Sibarani, Jupiter; Romdan, Tjahjodjati; Adi, Kuncoro; Hernowo, Bethy S; Yantisetiasti, Anglita
2017-01-01
Urethral stricture has a high recurrence rate. There is a common doctrine stating that "once a stricture, always a stricture". This fibrotic disease pathophysiology, pathologically characterized by excessive production, deposition and contraction of extracellular matrix is unknown. Angiotensin II type 1 (AT 1 ) receptor primarily induces angiogenesis, cellular proliferation and inflammatory responses. AT 1 receptors are also expressed in the fibroblasts of hypertrophic scars, whereas angiotensin II (AngII) regulates DNA synthesis in hypertrophic scar fibroblasts through a negative cross talk between AT 1 and angiotensin II type 2 (AT 2 ) receptors, which might contribute to the formation and maturation of human hypertrophic scars. This study was conducted to determine the expression of AT 1 receptors in urethral stricture tissues. Urethral stricture tissues were collected from patients during anastomotic urethroplasty surgery. There were 24 tissue samples collected in this study with 2 samples of normal urethra for the control group. Immunohistochemistry study was performed to detect the presence of AT 1 receptor expression. Data were analyzed using Mann-Whitney U test, and statistical analysis was performed with SPSS version 20. This study showed that positive staining of AT 1 receptor was found in all urethral stricture tissues (n=24). A total of 8.33% patients had low intensity, 41.67% had moderate intensity and 50% had high intensity of AT 1 receptors, while in the control group, 100% patients had no intensity of AT 1 receptors. Using the Mann-Whitney U test, it was found that urethral stricture tissue had a higher intensity of AT 1 receptors than normal urethral tissue with a p -value = 0.012. The results showed that AT 1 receptor had a higher intensity in the urethral stricture tissue and that AT 1 receptor may play an important role in the development of urethral stricture.
Grov, Christian; Cain, Demetria; Rendina, H Jonathan; Ventuneac, Ana; Parsons, Jeffrey T
2016-03-01
Gay and bisexual men are at elevated risk for Neisseria gonorrhoeae and Chlamydia trachomatis (GC/CT). Rectal GC/CT symptoms may be less obvious than urethral, increasing opportunities for undiagnosed rectal GC/CT. A US national sample of 1071 gay and bisexual men completed urethral and rectal GC/CT testing and an online survey. In total, 6.2% were GC/CT positive (5.3% rectal, 1.7% urethral). We calculated adjusted (for education, race, age, relationship status, having health insurance, and income) odds ratios for factors associated with rectal and urethral GC/CT diagnoses. Age was inversely associated with urethral and rectal GC/CT. Compared with white men, Latinos had significantly greater odds of rectal GC/CT. Among men who reported anal sex, those reporting only insertive sex had lower odds of rectal GC/CT than did men who reported both insertive and receptive. There was a positive association between rectal GC/CT and number of male partners (<12 months), the number of anal receptive acts, receptive condomless anal sex (CAS) acts, and insertive CAS acts. Compared with those who had engaged in both insertive and receptive anal sex, those who engaged in only receptive anal sex had lower odds of urethral GC/CT. The number of male partners (<12 months) was associated with increased odds of urethral GC/CT. Rectal GC/CT was more common than urethral and associated with some demographic and behavioral characteristics. Our finding that insertive CAS acts was associated with rectal GC/CT highlights that providers should screen patients for GC/CT via a full range of transmission routes, lest GC/CT go undiagnosed.
Singh, Bhupendra P; Andankar, Mukund G; Swain, Sanjaya K; Das, Krishanu; Dassi, Vimal; Kaswan, Harish K; Agrawal, Vipul; Pathak, Hemant R
2010-01-01
To determine the impact of earlier urethral interventions on the outcomes of anastomotic urethroplasty in post-traumatic stricture urethra. From October 1995 to March 2008, a total of 58 patients with post-traumatic posterior urethral stricture underwent anastomotic urethroplasty. Eighteen patients had earlier undergone urethral intervention in the form of urethrotomy (3), endoscopic realignment (7), or open urethroplasty (8). Success was defined as no obstructive urinary symptoms, maximum urine flow rate > or = 15 mL/s, normal urethral imaging and/or urethroscopy, and no need of any intervention in the follow-up period. Patients who met the above objective criteria after needing 1 urethrotomy following urethroplasty were defined to have satisfactory outcome and were included in satisfactory result rate along with patients who had a successful outcome. Results were analyzed using unpaired t test, chi-square test, binary logistic regression, Kaplan-Meier curves, and log rank test. Previous interventions in the form of endoscopic realignment or urethroplasty have significant adverse effect on the success rate of subsequent anastomotic urethroplasty for post-traumatic posterior urethral strictures (P <.05). Previous intervention in the form of visual internal urethrotomies (up to 2 times) did not affect the outcome of subsequent anastomotic urethroplasty. Length of stricture and age of patient did not predict the outcome in traumatic posterior urethral strictures in logistic regression analysis. Previous failed railroading or urethroplasty significantly decrease the success of subsequent anastomotic urethroplasty. Hence, a primary realignment or urethroplasty should be avoided in suboptimal conditions and the cases of post-traumatic urethral stricture should be referred to centers with such expertise. 2010 Elsevier Inc. All rights reserved.
Trends in stricture management among male Medicare beneficiaries: underuse of urethroplasty?
Anger, Jennifer T; Buckley, Jill C; Santucci, Richard A; Elliott, Sean P; Saigal, Christopher S
2011-02-01
To analyze the trends in male urethral stricture management using the 1992-2001 Medicare claims data and to determine whether certain racial and ethnic groups have a disproportionate burden of urethral stricture disease. We analyzed the Medicare claims for fiscal years 1992, 1995, 1998, and 2001. The "International Classification of Disease, 9th revision," diagnosis codes were used to identify men with urethral stricture. The demographic characteristics assessed included patient age, race, and comorbidities, as measured using the Charlson index. Treatments were identified using the Physician Current Procedural Terminology Coding System, 4th edition, procedure codes and stratified into 4 treatment types: urethral dilation, direct vision internal urethrotomy, urethral stent/steroid injection, and urethroplasty. The overall rates of stricture diagnosis decreased from 10,088/100,000 population in 1992 to 6897 in 2001 (from 1.4% to 0.9%). The stricture prevalence was greatest among black and Hispanic men, although the urethroplasty rates were greatest among white men. Direct vision internal urethrotomy was the most common treatment, followed by urethral dilation, urethral stent/steroid injection, and urethroplasty. The urethroplasty rates remained stable, but quite low (0.6%-0.8%), during the study period. The overall rates of stricture diagnosis decreased from 1992 to 2001. Despite the poor overall efficacy of urethrotomy and urethral dilation relative to urethroplasty and despite the known complications of stent placement in this setting, the urethroplasty rates were the lowest of all treatments. Although we could not determine the treatment success with these data, these findings suggest an underuse of the most efficacious treatment of urethral stricture disease, urethroplasty. Copyright © 2011. Published by Elsevier Inc.
Orthotopic bladder substitution in men revisited: identification of continence predictors.
Koraitim, M M; Atta, M A; Foda, M K
2006-11-01
We determined the impact of the functional characteristics of the neobladder and urethral sphincter on continence results, and determined the most significant predictors of continence. A total of 88 male patients 29 to 70 years old underwent orthotopic bladder substitution with tubularized ileocecal segment (40) and detubularized sigmoid (25) or ileum (23). Uroflowmetry, cystometry and urethral pressure profilometry were performed at 13 to 36 months (mean 19) postoperatively. The correlation between urinary continence and 28 urodynamic variables was assessed. Parameters that correlated significantly with continence were entered into a multivariate analysis using a logistic regression model to determine the most significant predictors of continence. Maximum urethral closure pressure was the only parameter that showed a statistically significant correlation with diurnal continence. Nocturnal continence had not only a statistically significant positive correlation with maximum urethral closure pressure, but also statistically significant negative correlations with maximum contraction amplitude, and baseline pressure at mid and maximum capacity. Three of these 4 parameters, including maximum urethral closure pressure, maximum contraction amplitude and baseline pressure at mid capacity, proved to be significant predictors of continence on multivariate analysis. While daytime continence is determined by maximum urethral closure pressure, during the night it is the net result of 2 forces that have about equal influence but in opposite directions, that is maximum urethral closure pressure vs maximum contraction amplitude plus baseline pressure at mid capacity. Two equations were derived from the logistic regression model to predict the probability of continence after orthotopic bladder substitution, including Z1 (diurnal) = 0.605 + 0.0085 maximum urethral closure pressure and Z2 (nocturnal) = 0.841 + 0.01 [maximum urethral closure pressure - (maximum contraction amplitude + baseline pressure at mid capacity)].
Xu, Yue-Min; Sa, Ying-Long; Fu, Qiang; Zhang, Jiong; Xie, Hong; Jin, San-Bao
2009-07-01
Female urethral injury is rare, and there is no accepted standard approach for the repair of urethral strictures. To evaluate the efficacy of transpubic access using pedicle tubularized labial urethroplasty for urethral reconstruction in female patients with urethral obliterative strictures and urethrovaginal fistulas. Between January 1996 and December 2006, eight cases of female urethral strictures associated with urethrovaginal fistulas were treated using pedicle labial skin flaps. A flap of approximately 3x3.5x3cm of the labia minora or majora with its vascular pedicle was tubularized over an 18-22 Fr fenestrated silicone stent to create a neourethra. This technique was used in five women. Two flaps, approximately 1.5-3.5 cm, were taken from bilateral labia minora or majora and were pieced together to create a neourethra. This technique was used in three patients. We performed voiding cystourethrography and uroflowmetry to assess postoperative results. The patients were followed up for 10-118 mo (mean 48.25 mo) after the procedure. There were no postoperative complications. Two patients complained of dysuria, which resolved spontaneously after 2 wk. One patient experienced stress incontinence that resolved after 4 wk. At 3-mo follow-up, one patient complained of difficulty voiding; the urinary peak flow was 13 ml/s, and the patient was treated successfully with urethral dilation. All other patients had normal micturition following catheter removal. Pedicle labial urethroplasty is a reliable technique for the repair of extensive urethral damage, and a transpubic surgical approach provides wide and excellent exposure for the management of complex obliterative urethral strictures and urethrovaginal fistulas secondary to pelvic fracture.
Saaby, Marie-Louise; Klarskov, Niels; Lose, Gunnar
2013-11-01
to assess the urethral closure function by urethral pressure reflectometry (UPR) during intra-abdominal pressure-increase in SUI and continent women. Twenty-five urodynamically proven SUI women and eight continent volunteer women were assessed by ICIQ-SF, pad-weighing test, incontinence diary, and UPR. UPR was conducted during resting and increased intra-abdominal pressure (P(Abd)) by straining. Related values of P(Abd) and urethral opening pressure (P(o)) were plotted into an abdomino-urethral pressuregram. Linear regression of the values was conducted, and the slope of the line ("APIR") and the intercept with the y-axis found. By the equation of the line, Po was calculated for various values of P(Abd), for example, 50 cm H2O (P(o-Abd 50)). The resting P(o) (P(o-rest)) and APIR, respectively, significantly differed in SUI and continent women but could not separate the two groups. The urethral closure equation (UCE) based on P(o-rest) and APIR provided a more detailed characterization of a woman's closure function based on the permanent closure forces (primarily generated by the urethral sphincteric unit) and the adjunctive closure forces (primarily generated by the support system). P(o-Abd 50) and UCE, respectively, which express the combined permanent and adjunctive closure forces and estimate the efficiency of the closure function, separated SUI and continent women and were highly significantly negatively correlated with ICIQ-SF, pad test, and the number of incontinence episodes. New parameters for characterization of the urethral closure function and possible dysfunctions and its efficiency were provided. P(o-Abd 50) and UCE may be used as diagnostic tests and severity measures. © 2013 Wiley Periodicals, Inc.
Expressed prostate secretions in the study of human papillomavirus epidemiology in the male.
Smelov, Vitaly; Eklund, Carina; Bzhalava, Davit; Novikov, Andrey; Dillner, Joakim
2013-01-01
Exploring different sampling sites and methods is of interest for studies of the epidemiology of HPV infections in the male. Expressed prostate secretions (EPS) are obtained during digital rectal examination (DRE), a daily routine urological diagnostic procedure, following massage of the prostate. Urethral swabs and EPS samples were obtained from a consecutive sample of 752 men (mean age 32.4 years; median life-time sex partners 34) visiting urology outpatient clinics in St. Petersburg, Russia and tested for HPV DNA by general primer PCR, followed by genotyping using Luminex. Overall, 47.9% (360/752) of men were HPV-positive, with 42.0% (316/752) being positive for high-risk (HR-) HPV and 12.6% (95/752) for multiple HPV types. HPV-positivity in the EPS samples was 32.6% (27.7% HR-HPV) and in the urethral samples 25.9% (24.5% HR-HPV). 10.6% were HPV positive in both EPS and urethral samples. 6.4% had the same HPV-type in both EPS and urethral samples. 10.6% were HPV positive in both EPS and urethral samples. 6.4% had the same HPV-type in both EPS and urethral samples. The concordance between the urethral samples and EPS was 62.5% (470/752), with 80 cases double positive and 390 cases double negative in both sites. The sensitivity of urethral samples for overall HPV detection was 54.2% (195/360). Compared to analysis of urethral samples only, the analysis of EPS increased the HPV prevalence in this population with 26.2%. EPS represent informative sampling material for the study of HPV epidemiology in the male.
Estimating the spatial resolution of fNIRS sensors for BCI purposes
NASA Astrophysics Data System (ADS)
Almajidy, Rand Kasim; Kirch, Robert D.; Christ, Olaf; Hofmann, Ulrich G.
2014-03-01
Differential near infrared sensors recently sparked a growing interest as a promising measuring modality for brain computer interfacing. In our study we present the design and characterization of novel, differential functional NIRS sensors, intended to record hemodynamic changes of the human motor cortex in the hand-area during motor imagery tasks. We report on the spatial characterization of a portable, multi-channel NIRS system with one module consisting of two central light emitting diodes (LED) (770 nm and 850 nm) and four symmetric pairs of radially aligned photodiodes (PD) resembling a plus symbol. The other sensor module features four similar, differential light paths crossing in the center of a star. Characterization was performed on a concentric, double beaker phantom, featuring a PBS/intralipid/blood mixture (97/1/2%). In extension of previous work, the inner, oxygenated beaker was covered by neoprene sleeves with holes of various sizes, thus giving an estimate on the spatial limits of the NIRS sensor's measurement volume. The star shaped sensor module formed a diffuse focus of approximately 3 cm in diameter at 1.4 cm depth, whereas the plus shaped arrangement suggested a concentric ring of four separate regions of interest, overall larger than 6 cm. The systems measurement sensitivity could be improved by removing ambient light from the sensing photodiodes by optical filtering. Altogether, we conclude that both our novel fNIRS design as well as its electronics perform well in the double-layered oxygenation phantom and are thus suitable for in-vivo testing.
Negative pressures during swing phase in below-knee prostheses with rubber sleeve suspension.
Chino, N; Pearson, J R; Cockrell, J L; Mikishko, H A; Koepke, G H
1975-01-01
Negative pressures in the small space between the distal stump and the below-knee prosthetic socket were measured during swing phase for a series of nine subjects. A molded rubber sleeve connecting the prosthesis and the thigh was found to enhance this effect so that suction suspension occurred during the entire swing phase. Deterioration of the suction occurred when the sleeve was intentionally pierced, and when other suspensions such as a suprapatellar cuff or thigh band were tested. The findings indicate that the total-contact socket, gel liner and elastic sleeve combine to create suction in the below-knee socket which improves overall comfort and function for the patient in using the prosthesis.
Imai, Kazuhiro; Minamiya, Yoshihiro; Saito, Hajime; Miyakoshi, Naohisa; Hongo, Michio; Kasukawa, Yuji; Ishikawa, Yoshinori; Motoyama, Satoru; Sato, Yusuke; Shimada, Yoichi; Ogawa, Jun-ichi
2013-07-01
We describe a novel technique of using halo-vest-enforced immobilization to relieve anastomotic tension after tracheal sleeve resection. Immediately after the tracheal sleeve resection, four halo titanium pins were inserted in the skulls of the patients to secure the halo-vest. All patients fitted with halo-vests were able to eat and drink and their clinical course was good. Bronchoscopy confirmed the absence of anastomotic leaks and stenoses, and there were no complications associated with the halo-vest. We believe that ensuring neck flexion using a halo-vest after tracheal sleeve resection is an excellent way of relieving anastomotic tension that would predispose the wound to dehiscence.
21 CFR 876.5520 - Urethral dilator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urethral dilator. 876.5520 Section 876.5520 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5520 Urethral dilator. (a...
Male urethral strictures and their management
Hampson, Lindsay A.; McAninch, Jack W.; Breyer, Benjamin N.
2014-01-01
Male urethral stricture disease is prevalent and has a substantial impact on quality of life and health-care costs. Management of urethral strictures is complex and depends on the characteristics of the stricture. Data show that there is no difference between urethral dilation and internal urethrotomy in terms of long-term outcomes; success rates range widely from 8–80%, with long-term success rates of 20–30%. For both of these procedures, the risk of recurrence is greater for men with longer strictures, penile urethral strictures, multiple strictures, presence of infection, or history of prior procedures. Analysis has shown that repeated use of urethrotomy is not clinically effective or cost-effective in these patients. Long-term success rates are higher for surgical reconstruction with urethroplasty, with most studies showing success rates of 85–90%. Many techniques have been utilized for urethroplasty, depending on the location, length, and character of the stricture. Successful management of urethral strictures requires detailed knowledge of anatomy, pathophysiology, proper patient selection, and reconstructive techniques. PMID:24346008
Urethral pressure response patterns induced by squeeze in continent and incontinent women.
Teleman, Pia M; Mattiasson, Anders
2007-09-01
Our aim was to compare the urethral pressure response pattern to pelvic floor muscle contractions in 20-27 years old, nulliparous continent women (n = 31) to that of continent (n = 28) and formerly untreated incontinent (n = 59) (53-63 years old) women. These women underwent urethral pressure measurements during rest and repeated pelvic muscle contractions. The response to the contractions was graded 0-4. The young continent women showed a mean urethral pressure response of 2.8, the middle-aged continent women 2.2 (NS vs young continent), and the incontinent women 1.5 (p < 0.05 vs middle-aged continent, p < 0.001 vs young continent). Urethral pressures during rest were significantly higher in the younger women than in both groups of middle-aged women. The decreased ability to increase urethral pressure on demand seen in middle-aged incontinent women compared to continent women of the same age as well as young women seems to be a consequence of a neuromuscular disorder rather than of age.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-10-09
Following the ignition of crude oil that leaked from a fractured 22 in. oil pipeline at a levee crossing at Berwick, Louisiana, on 1/2/80, NTSB has recommended that Texaco Pipeline Co., the line owner, review the practice of using fillet-welded reinforcement sleeves for tie-in welds to determine if these sleeves have caused any pipeline failures in its system; notify the pipeline patrol of the location of such existing sleeves and instruct it to examine the areas around these sleeves for signs of leakage; and evaluate existing procdures for leak detection to make these procedures more effective. The American Petroleum Institutemore » has also been urged to notify its member companies of the Berwick accident and the aforementioned recommendations. These pipeline and other safety recommendation letters and reports of accidents, including the determination of the cause of the explosion, burning, and sinking of the Liberian tanker Seatige.« less
NASA Technical Reports Server (NTRS)
Rothrock, A M; Marsh, E T
1935-01-01
Test data and analysis show that the rate of fuel leakage between a lapped plunger and sleeve varies directly with the density of the fuel, the diameter of the plunger, the pressure producing the leakage, and the cube of the mean clearance between the plunger and sleeve. The rate varies inversely as the length of the lapped fit and the viscosity of the fuel. With a mean clearance between the plunger and sleeve of 0.0001 inch the leakage amounts to approximately 0.2 percent of the fuel injected with gasoline and as low as 0.01 percent with diesel fuel oils. With this mean clearance an effective seal is obtained when the length of the lap is three times the diameter of the lap. The deformation of the sleeve and plunger under pressure is sufficient to change the rate of leakage appreciably from that which would be obtained if the clearance was constant under pressure.
Lei, Hongen; Guan, Xing; Han, Hu; Qian, Xiaosong; Zhou, Xiaoguang; Zhang, Xiaodong; Tian, Long
2018-06-01
Klippel-Trenaunay syndrome (KTS) is a rare congenital vascular disorder characterized by a triad of cutaneous port wine capillary malformations, varicose veins, and hemihypertrophy of bone and soft tissues. To report on a rare case of KTS in an adult man manifested by painless urethral bleeding during penile erection briefly review the clinical presentation and management of the genitourinary forms of this syndrome. On presentation, the clinical features of this patient, including medical history, signs and symptoms, and imaging examinations, were recorded. After diagnosis and initial treatment, a literature review of the urethral features of KTS was performed and is discussed in this report. A 35-year-old man with KTS presented with painless urethral bleeding during penile erection that was associated with posterior urethral vascular malformations. The coagulation method was used to treat the malformation, and no urethral bleeding or gross hematuria occurred during a postoperative follow-up period of 6 months. This case demonstrates that coagulation therapy and careful follow-up can be adequate treatment approaches for urethral features of KTS. However, the long-term efficacy of coagulation for this disorder should be investigated further. Lei H, Guan X, Han H, et al. Painless Urethral Bleeding During Penile Erection in an Adult Man With Klippel-Trenaunay Syndrome: A Case Report. Sex Med 2018;6:180-183. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Prakash, Gaurav; Singh, Bhupendra Pal; Sinha, Rahul Janak; Jhanwar, Ankur; Sankhwar, Satyanarayan
2018-01-01
For dorsal onlay graft placement, unilateral urethral mobilization is less invasive than standard circumferential urethral mobilization. Apart from success in terms of patency of urethra, other issues like sexual function, overall quality of life and patient satisfaction remain important issues while comparing outcomes of urethroplasty. To prospectively compare the objective as well as subjective outcomes of two approaches. Between July 2011 and January 2015, 136 adult males having anterior urethral stricture with urethral lumen ≥ 6 Fr. were prospectively assigned between two groups by alternate randomization. Operative time, complications, success rate (no obstructive symptoms, no need of any postoperative intervention, Q max > 15mL/sec), sexual functions (using Brief Male Sexual Function Inventory) were compared. Baseline parameters were similar in both groups (68 in each group). Overall success rate was similar in both groups (89 % and 91 % respectively). Improvement in total LUTS scores was similar in groups. Changes in overall health status (VAS and EQ 5D) was equal in both groups. Erectile function score was significantly decreased in DO than DL group while ejaculatory function and sexual desire remained stable after urethroplasty in both groups. In anterior urethral stricture buccal mucosa graft provides satisfactory results as onlay technique. No technique whether dorsolateral and dorsal techniques is superior to other. Dorsolateral technique needs minimal urethral mobilization and should be preferred whenever feasible. Copyright® by the International Brazilian Journal of Urology.
Office dilation of the female urethra: a quality of care problem in the field of urology.
Santucci, Richard A; Payne, Christopher K; Anger, Jennifer T; Saigal, Christopher S
2008-11-01
Historically dilation of the female urethra was thought to be of value in the treatment of a variety of lower urinary tract symptoms. Subsequent work has more accurately classified these complaints as parts of various diseases or syndromes in which scant data exist to support the use of dilation. Yet Medicare reimbursement for urethral dilation remains generous and we describe practice patterns regarding female urethral dilation to characterize a potential quality of care issue. Health care use by females treated with urethral dilation was compiled using a complementary set of databases. Data sets were examined for relevant inpatient, outpatient and emergency room services for women of all ages. Female urethral dilation is common (929 per 100,000 patients) and is performed almost as much as treatment for male urethral stricture disease. Approximately 12% of these patients are subjected to costly studies such as retrograde urethrography. The overall national costs for treatment exceed $61 million per year and have increased 10% to 17% a year since 1994. A diagnosis of female urethral stricture increases health care expenditures by more than $1,800 per individual per year in insured populations. Urethral dilation is still common despite the fact that true female urethral stricture is an uncommon entity. This scenario is likely secondary to the persistence of the mostly discarded practice of dilating the unstrictured female urethra for a wide variety of complaints despite the lack of data suggesting that it improves lower urinary tract symptoms.
Hillman, R J; Ryait, B K; Botcherby, M; Taylor-Robinson, D
1993-01-01
OBJECTIVE--To assess the presence of human papillomavirus (HPV) DNA in urethral and urine specimens from men with and without sexually transmitted diseases. DESIGN--Prospective study. SETTING--Two London departments of genitourinary medicine PATIENTS--100 men with urethral gonorrhoea, 31 men with penile warts and 37 men with genital dermatoses. METHODS--Urethral and urine specimens were taken, HPV DNA extracted and then amplified using the polymerase chain reaction. HPV types 6, 11, 16, 18, 31 and 33 were identified using Southern blotting followed by hybridisation. RESULTS--HPV DNA was detected in 18-31% of urethral swab specimens and in 0-14% of urine specimens. Men with penile warts had HPV detected in urethral swabs more often than did men in the other two clinical groups. "High risk" HPV types were found in 71-83% of swab specimens and in 73-80% of urine specimens containing HPV DNA. CONCLUSIONS--HPV is present in the urogenital tracts of men with gonorrhoea, penile warts and with genital dermatoses. In men with urethral gonorrhoea, detection of HPV in urethral specimens is not related to the number of sexual partners, condom usage, racial origin or past history of genital warts. HPV DNA in the urethral swab and urine specimens may represent different aspects of the epidemiology of HPV in the male genital tract. The preponderance of HPV types 16 and 18 in all three groups of men may be relevant to the concept of the "high risk male". Images PMID:8392967
Xu, Yue-Min; Qiao, Yong; Sa, Ying-Long; Wu, Den-Long; Zhang, Xin-Ru; Zhang, Jion; Gu, Bao-Jun; Jin, San-Bao
2007-04-01
We evaluated the applications and outcomes of substitution urethroplasty, using a variety of techniques, in 65 patients with complex, long-segment urethral strictures. From January 1995 to December 2005, 65 patients with complex urethral strictures >8cm in length underwent substitution urethroplasty. Of the 65 patients, 43 underwent one-stage urethral reconstruction using mucosal grafts (28 colonic mucosal graft, 12 buccal mucosal graft, and 3 bladder mucosal graft), 17 patients underwent one-stage urethroplasty using pedicle flaps, and 5 patients underwent staged Johanson's urethroplasty. The mean follow-up time was 4.8 yr (range; 0.8-10 yr), with an overall success rate of 76.92% (50 of 65 cases). Complications developed in 15 patients (23.08%) and included recurrent stricture in 7 (10.77%), urethrocutaneous fistula in 3 (4.62%), coloabdominal fistula in 1 (1.54%), penile chordee in 2 (3.08%), and urethral pseudodiverticulum in 2 (3.08%). Recurrent strictures and urethral pseudodiverticulum were treated successfully with a subsequent procedure, including repeat urethroplasty in six cases and urethrotomy or dilation in three. Coloabdominal fistula was corrected only by dressing change; five patients await further reconstruction. Penile skin, colonic mucosal, and buccal mucosal grafts are excellent materials for substitution urethroplasty. Colonic mucosal graft urethroplasty is a feasible procedure for complicated urethral strictures involving the entire or multiple portions of the urethra and the technique may also be considered for urethral reconstruction in patients in whom other conventional procedures failed.
Podestá, M L; Medel, R; Castera, R; Ruarte, A
1997-04-01
We retrospectively reviewed the results of 3 types of initial management of pelvic fracture urethral disruption in children. From 1980 to 1994, 35 boys 2 to 15 years old (mean age 8.1) with prostatomembranous urethral disruption were treated, including 17 who also had associated injuries. Immediate treatment included suprapubic cystostomy and delayed urethroplasty in 19 patients (group 1), urethral catheter alignment without traction and concomitant suprapubic cystostomy in 10 (group 2), and primary retropubic anastomotic urethroplasty in 6 (group 3). In all patients in groups 1 and 2 severe urethral obliteration developed. Four group 3 patients (66%) had a stricture at the site of anastomotic repair. After delayed urethroplasty 16 group 1 (84%) and all 10 group 2 patients were continent. However, only 3 group 3 patients (50%) achieved continence. Retrospectively associated bladder neck injury occurred in 5 of the 6 incontinent boys. Erections were observed before and after treatment in all but 3 children. Unstable pelvic ring fractures (type IV) comprised 28% of all pelvic fractures with a high rate of associated injuries. As described, urethral alignment was not beneficial for avoiding urethral obliteration. Therefore we recommend suprapublic cystostomy as the only form of initial treatment in these cases. Urinary incontinence seems more likely related to associated bladder neck rupture and the severity of pelvic fracture rather than to initial treatment or delayed urethral repair. Consequently, when associated bladder neck injury is present, we advocate immediate surgical repair.
Kadono, Yoshifumi; Nohara, Takahiro; Kawaguchi, Shohei; Naito, Renato; Urata, Satoko; Nakashima, Kazufumi; Iijima, Masashi; Shigehara, Kazuyoshi; Izumi, Kouji; Gabata, Toshifumi; Mizokami, Atsushi
2018-02-28
To assess the chronological changes in urinary incontinence and urethral function before and after radical prostatectomy (RP), and to compare the findings of pelvic magnetic resonance imaging (MRI) before and after RP to evaluate the anatomical changes. In total, 185 patients were evaluated with regard to the position of the distal end of the membranous urethra (DMU) on a mid-sagittal MRI slice and urethral sphincter function using the urethral pressure profilometry. The patients also underwent an abdominal leak point pressure test before RP and at 10 days and 12 months after RP. The results were then compared with the chronological changes in urinary incontinence. The MRI results showed that the DMU shifted proximally to an average distance of 4 mm at 10 days after RP and returned to the preoperative position at 12 months after RP. Urethral sphincter function also worsened 10 days after RP, with recovery after 12 months. The residual length of the urethral stump and urinary incontinence were significantly associated with the migration length of the DMU at 10 days after RP. The residual length of the urethral stump was a significant predictor of urinary incontinence after RP. This is the first study to elucidate that the slight vertical repositioning of the membranous urethra after RP causes chronological changes in urinary incontinence. A long urethral residual stump reduces urinary incontinence after RP. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.
Retractor Tool for Brain Surgery
NASA Technical Reports Server (NTRS)
Helms, R.; Hayes, T.
1982-01-01
Proposed brain-surgery tool has an octogonal fixture for positioning latex tube over incision. Eight stainless-steel wires embedded in latex extend to hold positioning fixture. Another eight are also embedded in the latex. Concentric sleeves are successively inserted into expandable latex tube. The first sleeve is placed over a solid rod. Last sleeve is a stainless-steel tube 1 inch in diameter. It is overcoated with Teflon (or equivalent) material.
Sleeve fracture of the adult patella: Case report and review of the literature.
Xie, Linjun; Xu, Hong; Zhang, Lizhi; Xu, Rong; Guo, Yingkun
2017-08-01
The patellar fractures are common in adults, but rare in children. As a particular type of patellar fracture, however, sleeve fractures are almost always limited to children in the under 16's group. Herein, we report a rare case of a 19-year-old healthy adult female who presented sleeve fracture at the superior pole of the left patella. The clinical and radiological features are found including joint effusion, anterior tilt of the patella and a shell of bone lying proximally to the patella. Computed tomography and magnetic resonance imaging examination have been performed to further confirm the diagnosis of sleeve fracture, rupture of the quadriceps tendon and the cartilaginous injury. Under general anaesthesia, she underwent open surgical procedures for reconstituting anatomically the fracture and repairing the rupture of the quadriceps tendon. Six months after the operation, she could fully use her left knee without any pain and disability. Sleeve fractures of the patellar in adults are extremely rare, and our case is of interest for the first time occurring in healthy female adults. Our case report and literature review was aim to describe the clinic and imaging characteristics of superior pole sleeve fractures in adults, and highlight that physicians must be aware of this entity in adults so as to reduce misdiagnosis due to unfamiliarity.
Crimped braided sleeves for soft, actuating arm in robotic abdominal surgery.
Elsayed, Yahya; Lekakou, Constantina; Ranzani, Tommaso; Cianchetti, Matteo; Morino, Mario; Arezzo, Alberto; Menciassi, Arianna; Geng, Tao; Saaj, Chakravarthini M
2015-01-01
This paper investigates different types of crimped, braided sleeve used for a soft arm for robotic abdominal surgery, with the sleeve required to contain balloon expansion in the pneumatically actuating arm while it follows the required bending, elongation and diameter reduction of the arm. Three types of crimped, braided sleeves from PET (BraidPET) or nylon (BraidGreyNylon and BraidNylon, with different monofilament diameters) were fabricated and tested including geometrical and microstructural characterisation of the crimp and braid, mechanical tests and medical scratching tests for organ damage of domestic pigs. BraidPET caused some organ damage, sliding under normal force of 2-5 N; this was attributed to the high roughness of the braid pattern, the higher friction coefficient of polyethylene terephthalate (PET) compared to nylon, and the high frequency of the crimp peaks for this sleeve. No organ damage was observed for the BraidNylon, attributed to both the lower roughness of the braid pattern and the low friction coefficient of nylon. BraidNylon also required the lowest tensile force during its elongation to similar maximum strain as that of BraidPET, translating to low power requirements. BraidNylon is recommended for the crimped sleeve of the arm designed for robotic abdominal surgery.
Alamdari, Nasser Malekpour; Bakhtiyari, Mahmood; Gholizadeh, Barmak; Shariati, Catrine
2018-03-01
The indications for sleeve gastrectomy as a primary procedure for the surgical treatment of morbid obesity have increased worldwide. Pain is the most common complaint for patients on the first day after laparoscopic sleeve gastrectomy. There are various methods for decreasing pain after laparoscopic sleeve gastrectomy such as the use of intraperitoneal bupivacaine hydrochloride. This clinical trial was an attempt to discover the effects of intraperitoneal bupivacaine hydrochloride on alleviating postoperative pain after laparoscopic sleeve gastrectomy. In general, 120 patients meeting the inclusion criteria were enrolled. Patients were randomly allocated into two interventions and control groups using a balanced block randomization technique. One group received intraperitoneal bupivacaine hydrochloride (30 cm 3 ), and the other group served as the control one and did not receive bupivacaine hydrochloride. Diclofenac suppository and paracetamol injection were administered to both groups for postoperative pain management. The mean subjective postoperative pain score was significantly decreased in patients who received intraperitoneal bupivacaine hydrochloride within the first 24 h after the surgery; thus, the instillation of bupivacaine hydrochloride was beneficial in managing postoperative pain. The intraoperative peritoneal irrigation of bupivacaine hydrochloride (30 cm 3 , 0.25%) in sleeve gastrectomy patients was safe and effective in reducing postoperative pain, nausea, and vomiting (IRCT2016120329181N4).
Aortic Root Biomechanics After Sleeve and David Sparing Techniques: A Finite Element Analysis.
Tasca, Giordano; Selmi, Matteo; Votta, Emiliano; Redaelli, Paola; Sturla, Francesco; Redaelli, Alberto; Gamba, Amando
2017-05-01
Aortic root aneurysm can be treated with valve-sparing procedures. The David and Yacoub techniques have shown excellent long-term results but are technically demanding. Recently, a new and simpler procedure, the Sleeve technique, was proposed with encouraging results. We aimed to quantify the biomechanics of the initially aneurysmal aortic root (AR) after the Sleeve procedure to assess whether it induces abnormal stresses, potentially undermining its durability. Two finite element (FE) models of the physiologic and aneurysmal AR were built, accounting for the anatomical asymmetry and the nonlinear and anisotropic mechanical properties of human AR tissues. On the aneurysmal model, the Sleeve and David techniques were simulated based on the corresponding published technical features. Aortic root biomechanics throughout 2 consecutive cardiac cycles were computed in each simulated configuration. Both sparing techniques restored physiologic-like kinematics of aortic valve (AV) leaflets but induced different leaflets stresses. The time course averaged over the leaflets' bellies was 35% higher in the David model than in the Sleeve model. Commissural stresses, which were equal to 153 and 318 kPa in the physiologic and aneurysmal models, respectively, became 369 and 208 kPa in the David and Sleeve models, respectively. No intrinsic structural problems were detected in the Sleeve model that might jeopardize the durability of the procedure. If corroborated by long-term clinical outcomes, the results obtained suggest that using this new technique could successfully simplify the surgical repair of AR aneurysms and reduce intraoperative complications. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Ibitoye, Ayo Zaccheaus; Nwoye, Ephraim Okeke; Aweda, Adebayo Moses; Oremosu, Ademola A; Anunobi, Chidozie Charles; Akanmu, Nurudeen Olanrewaju
2016-12-01
To study the efficiency of a dual slot antenna with a floating metallic sleeve on the ablation of different ex vivo bovine tissues. COMSOL Multiphysics® version 4.4 (Stockholm, Sweden), which is based on finite element methods (FEM), was used to design and simulate monopole and dual slot with sleeve antennas. Power, specific absorption rate (SAR), temperature and necrosis distributions in the selected tissues were determined using these antennas. Monopole and dual slot with sleeve antennas were designed, simulated, constructed and applied in this study based on a semi-rigid coaxial cable. Ex vivo experiments were performed on liver, lung, muscle and heart of bovine obtained from a public animal slaughter house. The microwave energy was delivered using a 2.45 GHz solid-state microwave generator at 40 W for 3, 5 and 10 min. Aspect ratio, ablation length and ablation diameter were also determined on ablated tissues and compared with simulated results. Student's t-test was used to compare the statistically significant difference between the performance of the two antennas. The dual slot antenna with sleeve produces localised microwave energy better than the monopole antenna in all ablated tissues using simulation and experimental validation methods. There were significant differences in ablation diameter and aspect ratio between the sleeve antenna and monopole antenna. Additionally, there were no significant differences between the simulation and experimental results. This study demonstrated that the dual slot antenna with sleeve produced larger ablation zones and higher sphericity index in ex vivo bovine tissues with minimal backward heating when compared with the monopole antenna.
Sleeve gastrectomy and the risk of leak: a systematic analysis of 4,888 patients.
Aurora, Alexander R; Khaitan, Leena; Saber, Alan A
2012-06-01
Sleeve gastrectomy has become a popular stand-alone bariatric procedure with comparable weight loss and resolution of comorbidities to that of laparoscopic gastric bypass. The simplicity of the procedure and the decreased long-term risk profile make this surgery more appealing. Nonetheless, the ever present risk of a staple-line leak is still of great concern and needs further investigation. An electronic literature search of MEDLINE database plus manual reference checks of articles published on laparoscopic sleeve gastrectomy for morbid obesity and its complications was completed. Keywords used in the search were "sleeve gastrectomy" OR "gastric sleeve" AND "leak." We analyzed 29 publications, including 4,888 patients. We analyzed the frequency of leak after sleeve gastrectomy and its associated risks of causation. The risk of leak after sleeve gastrectomy in all comers was 2.4%. This risk was 2.9% in the super-obese [body mass index (BMI) > 50 kg/m(2)] and 2.2% for BMI < 50 kg/m(2). Staple height and use of buttressing material did not affect leak rate. The use of a size 40-Fr or greater bougie was associated with a leak rate of 0.6% compared with those who used smaller sizes whose leak rate was 2.8%. Leaks were found at the proximal third of the stomach in 89% of cases. Most leaks were diagnosed after discharge. Endoscopic management is a viable option for leaks and was documented in 11% of cases as successful. Sleeve gastrectomy has become an important surgical option for the treatment of the ever growing morbidly obese population. The risk of leak is low at 2.4%. Attention to detail specifically at the esophagogastric junction cannot be stressed enough. Careful patient selection (BMI < 50 kg/m(2)) and adopting the use of a 40-Fr or larger bougie may decrease the risk of leak. Vigilant follow-up during the first 30 days is critical to avoid catastrophe, because most leaks will happen after patient discharge.
Gastroesophageal reflux disease and morbid obesity: To sleeve or not to sleeve?
Rebecchi, Fabrizio; Allaix, Marco E; Patti, Marco G; Schlottmann, Francisco; Morino, Mario
2017-01-01
Laparoscopic sleeve gastrectomy (LSG) has reached wide popularity during the last 15 years, due to the limited morbidity and mortality rates, and the very good weight loss results and effects on comorbid conditions. However, there are concerns regarding the effects of LSG on gastroesophageal reflux disease (GERD). The interpretation of the current evidence is challenged by the fact that the LSG technique is not standardized, and most studies investigate the presence of GERD by assessing symptoms and the use of acid reducing medications only. A few studies objectively investigated gastroesophageal function and the reflux profile by esophageal manometry and 24-h pH monitoring, reporting postoperative normalization of esophageal acid exposure in up to 85% of patients with preoperative GERD, and occurrence of de novo GERD in about 5% of cases. There is increasing evidence showing the key role of the surgical technique on the incidence of postoperative GERD. Main technical issues are a relative narrowing of the mid portion of the gastric sleeve, a redundant upper part of the sleeve (both depending on the angle under which the sleeve is stapled), and the presence of a hiatal hernia. Concomitant hiatal hernia repair is recommended. To date, either medical therapy with proton pump inhibitors or conversion of LSG to laparoscopic Roux-en-Y gastric bypass are the available options for the management of GERD after LSG. Recently, new minimally invasive approaches have been proposed in patients with GERD and hypotensive LES: the LINX® Reflux Management System procedure and the Stretta® procedure. Large studies are needed to assess the safety and long-term efficacy of these new approaches. In conclusion, the recent publication of pH monitoring data and the new insights in the association between sleeve morphology and GERD control have led to a wider acceptance of LSG as bariatric procedure also in obese patients with GERD, as recently stated in the 5th International Consensus Conference on sleeve gastrectomy. PMID:28428706
Gastroesophageal reflux disease and morbid obesity: To sleeve or not to sleeve?
Rebecchi, Fabrizio; Allaix, Marco E; Patti, Marco G; Schlottmann, Francisco; Morino, Mario
2017-04-07
Laparoscopic sleeve gastrectomy (LSG) has reached wide popularity during the last 15 years, due to the limited morbidity and mortality rates, and the very good weight loss results and effects on comorbid conditions. However, there are concerns regarding the effects of LSG on gastroesophageal reflux disease (GERD). The interpretation of the current evidence is challenged by the fact that the LSG technique is not standardized, and most studies investigate the presence of GERD by assessing symptoms and the use of acid reducing medications only. A few studies objectively investigated gastroesophageal function and the reflux profile by esophageal manometry and 24-h pH monitoring, reporting postoperative normalization of esophageal acid exposure in up to 85% of patients with preoperative GERD, and occurrence of de novo GERD in about 5% of cases. There is increasing evidence showing the key role of the surgical technique on the incidence of postoperative GERD. Main technical issues are a relative narrowing of the mid portion of the gastric sleeve, a redundant upper part of the sleeve (both depending on the angle under which the sleeve is stapled), and the presence of a hiatal hernia. Concomitant hiatal hernia repair is recommended. To date, either medical therapy with proton pump inhibitors or conversion of LSG to laparoscopic Roux-en-Y gastric bypass are the available options for the management of GERD after LSG. Recently, new minimally invasive approaches have been proposed in patients with GERD and hypotensive LES: the LINX ® Reflux Management System procedure and the Stretta ® procedure. Large studies are needed to assess the safety and long-term efficacy of these new approaches. In conclusion, the recent publication of pH monitoring data and the new insights in the association between sleeve morphology and GERD control have led to a wider acceptance of LSG as bariatric procedure also in obese patients with GERD, as recently stated in the 5 th International Consensus Conference on sleeve gastrectomy.
Evaluation of the outcomes after posterior urethroplasty.
Liberman, Daniel; Pagliara, Travis J; Pisansky, Andrew; Elliott, Sean P
2015-03-01
Posterior urethral injury is a clinically significant complication of pelvic fractures. The management is complicated by the associated organ injuries, distortion of the pelvic anatomy and the ensuing fibrosis that occurs with urethral injury. We report a review of the outcomes after posterior urethroplasty in the context of pelvic fracture urethral injury.
Tran, Christine N; Reichard, Chad A; McMahon, Daniel; Rhee, Audrey
2014-08-01
Anterior urethral valve (AUV) associated with posterior urethral valves (PUVs) is an extremely rare congenital urologic anomaly resulting in lower urinary tract obstruction. We present our experience with 2 children with concomitant AUV and PUV as well as a literature review. The clinical presentation of concomitant AUV and PUV is variable. Successful endoscopic management can result in improvement in renal function, reversal of obstructive changes, and improvement or resolution of voiding dysfunction. Copyright © 2014 Elsevier Inc. All rights reserved.
Remote discovery of an asymptomatic bowel perforation by a mid-urethral sling.
Elliott, Jason E; Maslow, Ken D
2012-02-01
Bowel perforation is a rare complication of mid-urethral sling procedures and is usually reported shortly after the surgery. We report a remotely discovered asymptomatic bowel injury found at the time of subsequent surgery. The patient with a history of several prior pelvic surgeries underwent an uneventful retropubic mid-urethral sling placement. Five years later, during an abdominal sacrocolpopexy procedure, mesh from the mid-urethral sling was found perforating the wall of the cecum and fixating it to the right pelvic sidewall. Cecal wedge resection was performed to excise the sling mesh. Asymptomatic bowel perforation by mid-urethral sling mesh has not been previously reported. Pelvic and abdominal surgeons should be aware of the possibility of finding this injury in patients with prior sling surgeries.
Do we assess urethral function adequately in LUTD and NLUTD? ICI-RS 2015.
Gajewski, Jerzy B; Rosier, Peter F W M; Rahnama'i, Sajjad; Abrams, Paul
2017-04-01
Urethral function, as well as anatomy, play a significant role in voiding reflex and abnormalities in one or both contribute to the pathophysiology of Lower Urinary Tract Dysfunction (LUTD). We have several diagnostic tools to assess the urethral function or dysfunction but the question remains, are these adequate? This is a report of the proceedings of Think Tank P1: 'Do we assess urethral function adequately in LUTD and NLUTD?' from the annual International Consultation on Incontinence-Research Society, which took place September 22-24, 2014 in Bristol, UK. We have collected and discussed, as a committee, the evidence with regard to the urethra and the available relevant methods of testing urethral function, with the emphasis on female and male voiding dysfunction. We looked into previous research and clinical studies and compiled summaries of pertinent testing related to urethral function. The discussion has focused on clinical applications and the desirability of further development of functional tests and analyses in this field. There are limitations to most of the urethral function tests. Future perspectives and research should concentrate on further development of functional testing and imaging techniques with emphasis on standardization and clinical application of these tests. Neurourol. Urodynam. 36:935-942, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Lumen, Nicolaas; Hoebeke, Piet; Troyer, Bart De; Ysebaert, Barbara; Oosterlinck, Willem
2009-03-01
We retrospectively analyzed cases of anastomotic urethroplasty for posttraumatic urethral strictures that were done at our center. Surgical and functional outcomes were evaluated. The impact of previous urethral manipulations was assessed. Between 1993 and 2006, 61 males were treated with anastomotic urethroplasty because of urethral trauma after pelvic fracture. Mean followup was 67 months (range 19 to 173). In 21 of the 61 cases (34.4%) urethral manipulation had been performed previously (secondary cases) but had failed. All patients were treated via the perineal approach. In 9 patients (14.8%) recurrence was reported. The recurrence rate was higher in patients who underwent former treatment than in primary patients (19% vs 12.5%). Posttraumatic impotence was reported by 20 patients (32.8%) but in 2 erectile function was restored after treatment. One patient had minor stress incontinence. In 2 secondary cases the rectum was injured during the procedure but could be repaired. Anastomotic urethroplasty via the perineal approach is an excellent treatment for posttraumatic urethral stricture. Results are good at long-term followup. Although statistical significance has not been attained, failures and complications seem to be higher in patients who have already undergone failed urethroplasty.
Mycoplasmataceae Colonizations in Women With Urethral Pain Syndrome: A Case-Control Study.
Kyndel, Anna; Elmér, Caroline; Källman, Owe; Altman, Daniel
2016-07-01
To determine if Mycoplasma genitalium, Ureaplasma urealyticum, and Ureaplasma parvum are more common in premenopausal women with urethral pain syndrome than in asymptomatic controls. We used a case-control study design to compare the prevalence of M. genitalium, U. urealyticum, and U. parvum using polymerase chain reaction (PCR) analysis in urine. Urethral pain syndrome was defined as localized urethral pain with or without accompanying lower urinary tract symptoms during the past month or longer and at least one negative urine culture. Among the 28 cases, 46% carried Ureaplasma species compared with 64% of the 92 controls overall (P = 0.09). There were no significant differences in the prevalence of U. parvum and U. urealyticum among controls than in patients with urethral pain syndrome (P = 0.35 and P = 0.33, respectively). Co-colonization with U. parvum and urealyticum was infrequent, and there was only one case of M. genitalium colonization, which occurred among the controls. The symptomatic profile of Ureaplasma carriers with urethral pain syndrome was heterogeneous with no clear pattern and did not differ significantly compared with patients negative for Ureaplasma. We found no evidence to support the notion that M. genitalium, U. parvum, and U. urealyticum are more prevalent in women with urethral pain syndrome than in women without lower urinary tract symptoms.
NASA Technical Reports Server (NTRS)
Schmidt, G. K.
1979-01-01
A booms and mechanisms subsystem was designed, developed, and qualified for the geostationary scientific satellite GEOS. Part of this subsystem consist of four axial booms consisting of one pair of 1 m booms and one pair of 2.5 m booms. Each of these booms is carrying one bird cage electric field sensor. Alignment accuracy requirements led to a telescopic type solution. Deployment is performed by pressurized nitrogen. At deployment in orbit two of these booms showed some anomalies and one of these two deployed only about 80%. Following this malfunction a detailed failure investigation was performed resulting in a design modification of some critical components as release mechanism, guide sleeves of the telescopic elements, and pressure system.
Eshiobo, Irekpita; Ehizomen, Esezobor; Omosofe, F; Onuora, V
2016-01-01
Urethral stricture disease is prevalent, and many surgical techniques have been developed to treat it. Currently, urethroplasty for bulbar strictures implies ventral or dorsal stricturotomy and a buccal mucosa graft (BMG) patch. To describe the surgical approach of the ventral patch BMG urethroplasty for proximal bulbar urethral stricture and to analyze 11 consecutive cases for whom the technique was used. The diagnosis of urethral stricture was confirmed with a combined retrograde urethrography and micturating cystourethrography. A single team exposed the urethra, harvested, and planted the BMG in the lithotomy position under general anesthesia. The oral preoperative preparation was done with oraldene (hexetidine) mouth wash three times daily beginning from the 2 nd preoperative day. The buccal mucosa was harvested from the left inner cheek in all the patients. The donor site was left unclosed but packed with wet gauze. Data related to age, preoperative adverse conditions, stricture length, urine culture result, perineal/oral wound complications, postoperative residual urine volume, and duration of hospital stay were recorded. Eleven patients with proximal bulbar urethral stricture had BMG urethroplasty from August 2013 to October 2015. Stricture length ranged from 2 to 5 cm. In six (54%) of the men, the stricture resulted from urethritis thereby constituting the most common etiology of urethral stricture in this study. The preoperative adverse conditions were age above 70 in three, diabetes mellitus in two, severe dental caries in one, and recurrent stricture in two. All of them were able to resume reasonable oral intake 72 h postoperatively. One (9.2%) had perineal wound infection, while two (18.2%) still had mild pain at donor site 4 weeks postoperatively. Ten (90.9%) of the 11 patients had <30 ml residual urine volume at 2 months of follow-up. Urethritis is still a common cause of urethral stricture in this rural community. Ventral onlay buccal mucosal graft urethroplasty for proximal bulbar urethral stricture is safe, even in certain adverse preoperative conditions. Buccal mucosa from the cheek is however now preferred.
Urethral stricture Yemen experience.
Al-Ba'adani, Tawfik H; Al-Asbahi, Walid; Al-Towaity, Mansour; Alwan, Mohammed; Al-Germozi, Shehab; Ghilan, Abdulelah; Telha, Khaled; Ben Godal, Mohammed; El-Nono, Ibraheim
2010-09-01
In order to evaluate the etiology of urethral stricture in our society and outcome of different types of surgical reconstruction used to treat them. This prospective study was carried out in the Urology and Nephrology Center, at Al-Thawra Modern General and Teaching Hospital, Sana'a, Yemen from July 2003 to July 2007 and included 62 male patients with complete urethral stricture whom underwent Urethral reconstructive surgery. The patients were evaluated by history, local and systemic physical examination, and radiological assessment according to each case. Patient's age ranged between 3 and 70 years (mean 25.31). Of 55 patients presented to the GER, 31 patients had car accident, 14 patients had gun shot injury, 9 patients fell from high, and one patient had bomb explosion. Five patients had history of traumatized catheterization and urethrocystoscopy, while two patients had history of urethritis. The site of the stricture was at the bulbomembranous area in 43 patients, in the penile urethra in 14 patients, and in bulbous urethra in 5 patients. The length of the urethral stricture was 10-30 mm in 39 patients (63%), <10 mm in 13 patients (21%) and of 30-70 mm in 10 patients (16%). A total of 15 patients (24%) with posterior urethral stricture of 10 mm or less (+2 patients with 1.2 and 1.5 cm), subjected to endoscopic treatment, 37 patients (60%) with stricture >10-30 mm, were underwent anastomotic urethral reconstruction and 10 patients (15%) with stricture >30 mm, were repaired utilizing tissue transfer technique. Follow-up period ranged from 3 months to 2 years (median 15 months), in which recurrent stricture was found in 11 patients (18%), wound dehiscence in 4 patients (6%) and fistula formation in 1 patient (1.5%), while no patient came with erectile dysfunction. Trauma is the commonest cause of urethral stricture in our country, therefore the control of it will decrease extremely the urethral stricture disease. No one technique is suitable for all types of the stricture, and the surgeon should be familiar with the different techniques and choose the most suitable one according to the case he deals with.
Urethral Pain Among Prostate Cancer Survivors 1 to 14 Years After Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pettersson, Niclas, E-mail: niclas.pettersson@vgregion.se; Olsson, Caroline; Tucker, Susan L.
Purpose: To investigate how treatment-related and non-treatment-related factors impact urethral pain among long-term prostate cancer survivors. Methods and Materials: Men treated for prostate cancer with radiation therapy at the Sahlgrenska University Hospital in Goeteborg, Sweden from 1993 to 2006 were approached with a study-specific postal questionnaire addressing symptoms after treatment, including urethral burning pain during urination (n=985). The men had received primary or salvage external-beam radiation therapy (EBRT) or EBRT in combination with brachytherapy (BT). Prescribed doses were commonly 70 Gy in 2.0-Gy fractions for primary and salvage EBRT and 50 Gy plus 2 Multiplication-Sign 10.0 Gy for EBRT +more » BT. Prostatic urethral doses were assessed from treatment records. We also recruited 350 non-pelvic-irradiated, population-based controls matched for age and residency to provide symptom background rates. Results: Of the treated men, 16% (137 of 863) reported urethral pain, compared with 11% (27 of 242) of the controls. The median time to follow-up was 5.2 years (range, 1.1-14.3 years). Prostatic urethral doses were similar to prescription doses for EBRT and 100% to 115% for BT. Fractionation-corrected dose and time to follow-up affected the occurrence of the symptom. For a follow-up {>=}3 years, 19% of men (52 of 268) within the 70-Gy EBRT + BT group reported pain, compared with 10% of men (23 of 222) treated with 70 Gy primary EBRT (prevalence ratio 1.9; 95% confidence interval 1.2-3.0). Of the men treated with salvage EBRT, 10% (20 of 197) reported urethral pain. Conclusions: Survivors treated with EBRT + BT had a higher risk for urethral pain compared with those treated with EBRT. The symptom prevalence decreased with longer time to follow-up. We found a relationship between fractionation-corrected urethral dose and pain. Among long-term prostate cancer survivors, the occurrence of pain was not increased above the background rate for prostatic urethral doses up to 70 Gy{sub 3}.« less
Long-term outcome of surgical treatment of penile fracture complicated by urethral rupture.
El-Assmy, Ahmed; El-Tholoth, Hossam S; Mohsen, Tarek; Ibrahiem, El Housseiny I
2010-11-01
The combination of lesions of the penile urethra and the corpus cavernosum is rare and is likely to worsen the immediate and long-term prognosis. To assess the late effects of penile fractures complicated by urethral rupture treated by immediate surgical intervention. Fourteen patients with concomitant urethral rupture were treated surgically at our center. Those patients were seen in the outpatient follow-up clinic and were re-evaluated. Sexual Health Inventory for Men questionnaire, local examination, uroflowmetry and penile color Doppler ultrasound. The most common cause of penile fracture is sexual intercourse (50%). The site of tunical tear was in the proximal shaft of the penis in 3 patients (21%) and in the mid of the shaft in 11 patients (79%). Urethral injury was localized at the same level as the corpus cavernosum tear in all cases; and it was partial in 11 cases and complete in 3. Long-term follow-up (mean=90 months) was available for 12 patients; among whom there was no complications in 4 (33%), painful erection in 1 (8%), erectile dysfunction in 2 (17%), and palpable fibrous nodule in 5 (47%). All patients had a normal urinary flow except one who developed relative urethral narrowing that required regular dilatation for 1 month. The urethral injury complicating penile fracture is often partial and localized at the level of the corpora cavenosa tear. Standard treatment consists of immediate surgical repair of both urethral and corporal ruptures with no harmful long-term sequelae on urethral and erectile function in most of patients. © 2010 International Society for Sexual Medicine.
Urethral Foreign Bodies: Clinical Presentation and Management.
Palmer, Cristina J; Houlihan, Matthew; Psutka, Sarah P; Ellis, K Alexandria; Vidal, Patricia; Hollowell, Courtney M P
2016-11-01
To review a single institution's 15-year experience with urethral foreign bodies, including evaluation, clinical findings, and treatment. In total, 27 patients comprising 35 episodes of inserted urethral foreign bodies were reviewed at Cook County Hospital between 2000 and 2015. Retrospective chart review was performed to describe the clinical presentation, rationale for insertion, management, recidivism, and sequelae. Median patient age was 26 (range 12-60). Twenty-six patients (97 %) were male, 1 was female (3%). Items inserted included pieces of plastic forks, spoons, metal screws and aluminum, pieces of cardboard or paper, staples, writing utensils such as pens and pencils, as well as coaxial cable and spray foam sealant. Reported reasons for insertion were self-stimulation, erectile enhancement, and attention seeking. Presenting symptoms included dysuria, gross hematuria, urinary retention, urinary tract infection, and penile discharge. The most common technique for removal was manual extraction with extrinsic pressure (n = 19, 54%). Other methods include endoscopic retrieval (n = 8, 23%), open cystotomy (n = 1, 3%), and voiding to expel the foreign body (n = 7, 20%). Postremoval complications included urinary tract infection (n = 7), sepsis (n = 4), urethral false passage (n = 5), laceration (n = 5), and stricture (n = 1). We present the largest single-institutional series of urethral foreign bodies to date. Urethral foreign body insertion is a relatively rare occurrence and, commonly, is a recurrent behavior. Urethral trauma related to foreign body insertion is associated with significant risk of infection and urethral injury with long-term sequelae. Copyright © 2016 Elsevier Inc. All rights reserved.
Wang, Lin; Lv, Xiangguo; Jin, Chongrui; Guo, Hailin; Shu, Huiquan; Fu, Qiang; Sa, Yinglong
2018-02-01
To develop a standardized PU-score (posterior urethral stenosis score), with the goal of using this scoring system as a preliminary predictor of surgical complexity and prognosis of posterior urethral stenosis. We retrospectively reviewed records of all patients who underwent posterior urethral surgery at our institution from 2013 to 2015. The PU-score is based on 5 components, namely etiology (1 or 2 points), location (1-3 points), length (1-3 points), urethral fistula (1 or 2 points), and posterior urethral false passage (1 point). We calculated the score of all patients and analyzed its association with surgical complexity, stenosis recurrence, intraoperative blood loss, erectile dysfunction, and urinary incontinence. There were 144 patients who underwent low complexity urethral surgery (direct vision internal urethrotomy, anastomosis with or without crural separation) with a mean score of 5.1 points, whereas 143 underwent high complexity urethroplasty (anastomosis with inferior pubectomy or urethrorectal fistula repair, perineal or scrotum skin flap urethroplasty, bladder flap urethroplasty) with a mean score of 6.9 points. The increase of PU-score was predictive of higher surgical complexity (P = .000), higher recurrence (P = .002), more intraoperative blood loss (P = .000), and decrease of preoperative (P = .037) or postoperative erectile function (P = .047). However, no association was observed between PU-score and urinary incontinence (P = .213). The PU-score is a novel and meaningful scoring system that describes the essential factors in determining the complexity and prognosis for posterior urethral stenosis. Copyright © 2017. Published by Elsevier Inc.
Horiguchi, Akio
2017-07-01
Male anterior urethral stricture is scarring of the subepithelial tissue of the corpus spongiosum that constricts the urethral lumen, decreasing the urinary stream. Its surgical management is a challenging problem, and has changed dramatically in the past several decades. Open surgical repair using grafts or flaps, called substitution urethroplasty, has become the gold standard procedure for anterior urethral strictures that are not amenable to excision and primary anastomosis. Oral mucosa harvested from the inner cheek (buccal mucosa) is an ideal material, and is most commonly used for substitution urethroplasty, and lingual mucosa harvested from the underside of the tongue has recently emerged as an alternative material with equivalent outcome. Onlay augmentation of oral mucosa graft on the ventral side (ventral onlay) or dorsal side (dorsal onlay, Barbagli procedure) has been widely used for bulbar urethral stricture with comparable success rates. In bulbar urethral strictures containing obliterative or nearly obliterative segments, either a two-sided dorsal plus ventral onlay (Palminteri technique) or a combination of excision and primary anastomosis and onlay augmentation (augmented anastomotic urethroplasty) are the procedures of choice. Most penile urethral strictures can be repaired in a one-stage procedure either by dorsal inlay with ventral sagittal urethrotomy (Asopa technique) or dorsolateral onlay with one-sided urethral dissection (Kulkarni technique); however, staged urethroplasty remains the procedure of choice for complex strictures, including strictures associated with genital lichen sclerosus or failed hypospadias. This article presents an overview of substitution urethroplasty using oral mucosa graft, and reviews current topics. © 2017 The Japanese Urological Association.
Total vaginectomy and urethral lengthening at time of neourethral prelamination in transgender men.
Medina, Carlos A; Fein, Lydia A; Salgado, Christopher J
2017-11-29
For transgender men (TGM), gender-affirmation surgery (GAS) is often the final stage of their gender transition. GAS involves creating a neophallus, typically using tissue remote from the genital region, such as radial forearm free-flap phalloplasty. Essential to this process is vaginectomy. Complexity of vaginal fascial attachments, atrophy due to testosterone use, and need to preserve integrity of the vaginal epithelium for tissue rearrangement add to the intricacy of the procedure during GAS. We designed the technique presented here to minimize complications and contribute to overall success of the phalloplasty procedure. After obtaining approval from the Institutional Review Board, our transgender (TG) database at the University of Miami Hospital was reviewed to identify cases with vaginectomy and urethral elongation performed at the time of radial forearm free-flap phalloplasty prelamination. Surgical technique for posterior vaginectomy and anterior vaginal wall-flap harvest with subsequent urethral lengthening is detailed. Six patients underwent total vaginectomy and urethral elongation at the time of radial forearm free-flap phalloplasty prelamination. Mean estimated blood loss (EBL) was 290 ± 199.4 ml for the vaginectomy and urethral elongation, and no one required transfusion. There were no intraoperative complications (cystotomy, ureteral obstruction, enterotomy, proctotomy, or neurological injury). One patient had a urologic complication (urethral stricture) in the neobulbar urethra. Total vaginectomy and urethral lengthening procedures at the time of GAS are relatively safe procedures, and using the described technique provides excellent tissue for urethral prelamination and a low complication rate in both the short and long term.
Office Dilation of the Female Urethra: A Quality of Care Problem in the Field of Urology
Santucci, Richard A.; Payne, Christopher K.; Saigal, Christopher S.
2008-01-01
Purpose: Historically dilation of the female urethra was thought to be of value in the treatment of a variety of lower urinary tract symptoms. Subsequent work has more accurately classified these complaints as parts of various diseases or syndromes in which scant data exist to support the use of dilation. Yet Medicare reimbursement for urethral dilation remains generous and we describe practice patterns regarding female urethral dilation to characterize a potential quality of care issue. Materials and Methods: Health care use by females treated with urethral dilation was compiled using a complementary set of databases. Data sets were examined for relevant inpatient, outpatient and emergency room services for women of all ages. Results: Female urethral dilation is common (929 per 100,000 patients) and is performed almost as much as treatment for male urethral stricture disease. Approximately 12% of these patients are subjected to costly studies such as retrograde urethrography. The overall national costs for treatment exceed $61 million per year and have increased 10% to 17% a year since 1994. A diagnosis of female urethral stricture increases health care expenditures by more than $1,800 per individual per year in insured populations. Conclusions: Urethral dilation is still common despite the fact that true female urethral stricture is an uncommon entity. This scenario is likely secondary to the persistence of the mostly discarded practice of dilating the unstrictured female urethra for a wide variety of complaints despite the lack of data suggesting that it improves lower urinary tract symptoms. PMID:18804232
Monti's procedure as an alternative technique in complex urethral distraction defect.
Hosseini, Jalil; Kaviani, Ali; Mazloomfard, Mohammad M; Golshan, Ali R
2010-01-01
Pelvic fracture urethral distraction defect is usually managed by the end to end anastomotic urethroplasty. Surgical repair of those patients with post-traumatic complex posterior urethral defects, who have undergone failed previous surgical treatments, remains one of the most challenging problems in urology. Appendix urinary diversion could be used in such cases. However, the appendix tissue is not always usable. We report our experience on management of patients with long urethral defect with history of one or more failed urethroplasties by Monti channel urinary diversion. From 2001 to 2007, we evaluated data from 8 male patients aged 28 to 76 years (mean age 42.5) in whom the Monti technique was performed. All cases had history of posterior urethral defect with one or more failed procedures for urethral reconstruction including urethroplasty. A 2 to 2.5 cm segment of ileum, which had a suitable blood supply, was cut. After the re-anastomosis of the ileum, we closed the opened ileum transversely surrounding a 14-16 Fr urethral catheter using running Vicryl sutures. The newly built tube was used as an appendix during diversion. All patients performed catheterization through the conduit without difficulty and stomal stenosis. Mild stomal incontinence occurred in one patient in the supine position who became continent after adjustment of the catheterization intervals. There was no dehiscence, necrosis or perforation of the tube. Based on our data, Monti's procedure seems to be a valuable technique in patients with very long complicated urethral defect who cannot be managed with routine urethroplastic techniques.
Detecting Solenoid Valve Deterioration in In-Use Electronic Diesel Fuel Injection Control Systems
Tsai, Hsun-Heng; Tseng, Chyuan-Yow
2010-01-01
The diesel engine is the main power source for most agricultural vehicles. The control of diesel engine emissions is an important global issue. Fuel injection control systems directly affect fuel efficiency and emissions of diesel engines. Deterioration faults, such as rack deformation, solenoid valve failure, and rack-travel sensor malfunction, are possibly in the fuel injection module of electronic diesel control (EDC) systems. Among these faults, solenoid valve failure is most likely to occur for in-use diesel engines. According to the previous studies, this failure is a result of the wear of the plunger and sleeve, based on a long period of usage, lubricant degradation, or engine overheating. Due to the difficulty in identifying solenoid valve deterioration, this study focuses on developing a sensor identification algorithm that can clearly classify the usability of the solenoid valve, without disassembling the fuel pump of an EDC system for in-use agricultural vehicles. A diagnostic algorithm is proposed, including a feedback controller, a parameter identifier, a linear variable differential transformer (LVDT) sensor, and a neural network classifier. Experimental results show that the proposed algorithm can accurately identify the usability of solenoid valves. PMID:22163597
Detecting solenoid valve deterioration in in-use electronic diesel fuel injection control systems.
Tsai, Hsun-Heng; Tseng, Chyuan-Yow
2010-01-01
The diesel engine is the main power source for most agricultural vehicles. The control of diesel engine emissions is an important global issue. Fuel injection control systems directly affect fuel efficiency and emissions of diesel engines. Deterioration faults, such as rack deformation, solenoid valve failure, and rack-travel sensor malfunction, are possibly in the fuel injection module of electronic diesel control (EDC) systems. Among these faults, solenoid valve failure is most likely to occur for in-use diesel engines. According to the previous studies, this failure is a result of the wear of the plunger and sleeve, based on a long period of usage, lubricant degradation, or engine overheating. Due to the difficulty in identifying solenoid valve deterioration, this study focuses on developing a sensor identification algorithm that can clearly classify the usability of the solenoid valve, without disassembling the fuel pump of an EDC system for in-use agricultural vehicles. A diagnostic algorithm is proposed, including a feedback controller, a parameter identifier, a linear variable differential transformer (LVDT) sensor, and a neural network classifier. Experimental results show that the proposed algorithm can accurately identify the usability of solenoid valves.
Kato, Haruaki; Kobayashi, Shinya; Kawakami, Masako; Inoue, Hiroo; Iijima, Kazuyoshi; Nishizawa, Osamu
2004-10-01
Repair of a posterior urethral disruption associated with a pelvic fracture is a challenge for urologic surgeons. Here, we provide surgical and strategic tips to facilitate the delayed surgical repair of urethral distraction defects. Nine patients each with a traumatic posterior urethral distraction defect underwent delayed transperineal or transperineoabdominal bulboprostatic anastomosis. Four patients had previously undergone multiple procedures. Seven patients regained satisfactory urination without incontinence, although one other patient is suffering from incontinence. In one patient, urethral disruption occurred again after removal of the urethral catheter, and he is being managed by suprapubic catheter. In our experience, the key to success is to perform a true bulboprostatic mucosa-to-mucosa anastomosis without tension. For this purpose, a transperineoabdominal approach is of particular importance when the healthy mucosa of the prostatic apex cannot be revealed through a perineal approach due to dense fibrous scar or fractured bone. A partial pubectomy may be necessary according to the situation. By the transperineoabdominal approach, the scar tissue can be bypassed through a broad sub-pubic-arch tunnel, and a reliable anastomosis achieved.
Fracture of the penis with urethral rupture.
Roy, Mk; Matin, Ma; Alam, Mm; Suruzzaman, M; Rahman, Mm
2008-01-01
We report a rare case of penile fracture with incomplete urethral rupture in a 25 years old male who sustained the injury during sexual intercourse. He presented with a tense haematoma on the ventral aspect of the penile shaft, associated with urethral bleeding. Per urethral catheterization was possible though it was painful. Exploration and repair of the penile fracture and urethra were performed within 16 hrs. The patient made an uneventful recovery with good erectile and voiding function. This case illustrates the value of early surgical repair of the fracture in order to prevent complications. The true incidence of penile fracture is not known even in the Western countries because it is under reported or hidden for social embracement and even it is reported to physicians it remains undiagnosed or mismanaged. Very rarely it is associated with urethral rupture.
Wlaszczuk, Adam; Marcol, Wiesław; Kucharska, Magdalena; Wawro, Dariusz; Palen, Piotr; Lewin-Kowalik, Joanna
2016-11-01
The influence of different kinds of nerve guidance conduits on regeneration of totally transected rat sciatic nerves through a 7-mm gap was examined. Five different types of conduits made of chitosan and poly(D,L-lactide-co-glycolide) (PLGA) were constructed and tested in vivo. We divided 50 animals into equal groups of 10, with a different type of conduit implanted in each group: chitosan sponge core with an average molecular mass of polymer (Mv) of 287 kDa with 7 channels in a PLGA sleeve, chitosan sponge core with an Mv of 423 kDa with 7 channels in a PLGA sleeve, chitosan sponge core (Mv, 423 kDa) with 13 channels in a PLGA sleeve, chitosan multifilament yarn in a PLGA sleeve, and a PLGA sleeve only. Seven weeks after the operation, we examined the distance covered by regenerating nerve fibers, growing of nerves into the conduit's core, and intensity and type of inflammatory reaction in the conduit, as well as autotomy behavior (reflecting neuropathic pain intensity) in the animals. Two types of conduits were allowing nerve outgrowth through the gap with minor autotomy and minor inflammatory reactions. These were the conduits with chitosan multifilament yarn in a PLGA sleeve and the conduits with 13-channel microcrystalline chitosan sponge in a PLGA sleeve. The type of chitosan used to build the nerve guidance conduit influences the intensity and character of inflammatory reaction present during nerve regeneration, which in turn affects the distance crossed by regenerating nerve fibers, growing of the nerve fibers into the conduit's core, and the intensity of autotomy in the animals. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Pelvic fracture urethral injuries: the unresolved controversy.
Koraitim, M M
1999-05-01
The unresolved controversies about pelvic fracture urethral injuries and whether any conclusions can be reached to develop a treatment plan for this lesion are determined. All data on pelvic fracture urethral injuries in the English literature for the last 50 years were critically analyzed. Studies were eligible only if data were complete and conclusive. The risk of urethral injury is influenced by the number of broken pubic rami as well as involvement of the sacroiliac joint. Depending on the magnitude of trauma, the membranous urethra is first stretched and then partially or completely ruptured at the bulbomembranous junction. Injuries to the prostatic urethra and bladder neck occur only in children. Injury to the female urethra usually is a partial tear of the anterior wall and rarely complete disruption of the proximal or distal urethra. Diagnosis depends on urethrography in men and on a high index of suspicion and urethroscopy in women. Of the 3 conventional treatment methods primary suturing of the disrupted urethral ends has the greatest complication rates of incontinence and impotence (21 and 56%, respectively). Primary realignment has double the incidence of impotence and half that of stricture compared to suprapubic cystostomy and delayed repair (36 versus 19 and 53 versus 97%, respectively, p <0.0001). In men surgical and endoscopic procedures do not compete but rather complement each other for treatment of different injuries under different circumstances, including indwelling catheter for urethral stretch injury, endoscopic stenting or suprapubic cystostomy for partial rupture, endoscopic realignment or suprapubic cystostomy for complete rupture with a minimal distraction defect and surgical realignment if the distraction defect is wide. Associated injury to the bladder, bladder neck or rectum dictates immediate exploration for repair but does not necessarily indicate exploration of the urethral injury site. In women treatment modalities are dictated by the level of urethral injury, including immediate retropubic realignment or suturing for proximal and transvaginal urethral advancement for distal injury.
Sleeve fracture of the adult patella
Xie, Linjun; Xu, Hong; Zhang, Lizhi; Xu, Rong; Guo, Yingkun
2017-01-01
Abstract Rationale: The patellar fractures are common in adults, but rare in children. As a particular type of patellar fracture, however, sleeve fractures are almost always limited to children in the under 16's group. Patient concerns: Herein, we report a rare case of a 19-year-old healthy adult female who presented sleeve fracture at the superior pole of the left patella. The clinical and radiological features are found including joint effusion, anterior tilt of the patella and a shell of bone lying proximally to the patella. Diagnoses: Computed tomography and magnetic resonance imaging examination have been performed to further confirm the diagnosis of sleeve fracture, rupture of the quadriceps tendon and the cartilaginous injury. Interventions: Under general anaesthesia, she underwent open surgical procedures for reconstituting anatomically the fracture and repairing the rupture of the quadriceps tendon. Outcomes: Six months after the operation, she could fully use her left knee without any pain and disability. Lessons: Sleeve fractures of the patellar in adults are extremely rare, and our case is of interest for the first time occurring in healthy female adults. Our case report and literature review was aim to describe the clinic and imaging characteristics of superior pole sleeve fractures in adults, and highlight that physicians must be aware of this entity in adults so as to reduce misdiagnosis due to unfamiliarity. PMID:28796028
Bickel, Amitai; Shturman, Alexander; Sergeiev, Michael; Ivry, Shimon; Eitan, Arieh; Atar, Shaul
2014-10-01
Pneumatic leg sleeves are widely used after prolonged operations for prevention of venous stasis. In healthy volunteers they increase cardiac function. We evaluated the hemodynamic effects and safety of intermittent sequential pneumatic compression (ISPC) leg sleeves in patients with chronic congestive heart failure (CHF). We studied 19 patients with systolic left ventricular dysfunction and CHF. ISPC leg sleeves, each with 10 air cells, were operated by a computerized compressor, exerting 2 cycles/min. Hemodynamic and echocardiographic parameters were measured before, during, and after ISPC activation. The baseline mean left ventricular ejection fraction was 29 ± 9.2%, median 32%, range 10%-40%. Cardiac output (from 4.26 to 4.83 L/min; P = .008) and stroke volume (from 56.1 to 63.5 mL; P = .029) increased significantly after ISPC activation, without a reciprocal increase in heart rate, and declined after sleeve deactivation. Systemic vascular resistance (SVR) decreased significantly (from 1,520 to 1,216 dyne-s/cm5; P = .0005), and remained lower than the baseline level throughout the study. There was no detrimental effect on diastolic function and no adverse clinical events, despite increased pulmonary venous return. ISPC leg sleeves in patients with chronic CHF do not exacerbate symptoms and transiently improve cardiac output through an increase in stroke volume and a reduction in SVR. Copyright © 2014 Elsevier Inc. All rights reserved.
Kabukoba, J J; Pearce, J M
1993-08-01
1. To design a device that would reduce contamination of staff during obstetric procedures. 2. To undertake clinical trials to assess the effectiveness and acceptability of such a device. A prospective study. The arm sleeve is made of a nonwoven material laminated on polyethylene film making it waterproof. It has an elastomeric cuff with adhesive that ensures a watertight seal between it and the glove. Delivery suite in a teaching hospital. Doctors and midwives were requested to wear the sleeve on top of the standard gown and gloves. Each user was assessed for blood contamination at the end of the procedure and a questionnaire detailing the extent of contamination and the views of the user was completed. Eighty questionnaires were completed. The contamination of arms and hands was 3.8% and 5%, respectively. Eighty-nine percent thought the sleeve had served its purpose and 76% said they would use it regularly. The sleeve is an effective protective device which complements the glove and gown. We recommend that it should be used during all obstetric procedures.
Airborne asbestos exposures associated with work on asbestos fire sleeve materials.
Blake, Charles L; Harbison, Stephen C; Johnson, Giffe T; Harbison, Raymond D
2011-11-01
Asbestos-containing fire sleeves have been used as a fire protection measure for aircraft fluid hoses. This investigation was conducted to determine the level of airborne asbestos fiber exposure experienced by mechanics who work with fire sleeve protected hoses. Duplicate testing was performed inside a small, enclosed workroom during the fabrication of hose assemblies. Personal air samples taken during this work showed detectable, but low airborne asbestos fiber exposures. Analysis of personal samples (n=9) using phrase contract microscopy (PCM) indicated task duration airborne fiber concentrations ranging from 0.017 to 0.063 fibers per milliliter (f/ml) for sampling durations of 167-198 min, and 0.022-0.14 f/ml for 30 min samples. Airborne chrysotile fibers were detected for four of these nine personal samples, and the resulting asbestos adjusted airborne fiber concentrations ranged from 0.014 to 0.025 f/ml. These results indicate that work with asbestos fire sleeve and fire sleeve protected hose assemblies, does not produce regulatory noncompliant levels of asbestos exposure for persons who handle, cut and fit these asbestos-containing materials. Copyright © 2011 Elsevier Inc. All rights reserved.
Chlamydia trachomatis in non-specific urethritis.
Terho, P
1978-01-01
Chlamydia trachomatis was isolated from 58.5% of 159 patients with non-specific urethritis (NSU) using irradiated McCoy cell cultures. Patients with persistent Chlamydia-positive NSU remained Chlamydia-positive each time they were examined before treatment and patients with Chlamydia-negative NSU remained Chlamydia-negative during the course of the illness. Neither the duration of symptoms of urethritis nor a history of previous urethritis affected the chlamydial isolation rate significantly. Of 40 patients with severe discharge 30 (75%) harboured C. trachomatis. One-third of the Chlamydia-positive patients had a severe urethral discharge, while this was present in only 15% of Chlamydia-negative patients. Complications--such as conjunctivitis, arthritis, and epididymitis--were more severe in men with Chlamdia-positive NSU than in those with Chlamydia-negative NSU. Of 64 men matched for sexual promiscuity but without urethritis, none harboured C. trachomatis in his urethra. This differs significantly (P less than 0.001) when compared with patients with NSU. C. trachomatis was isolated from the urogenital tract in 24 (42%) out of 57 female sexual contacts of patients with NSU. The presence of C. trachomatis in the women correlated significantly (P less than 0.001) with the isolation of the agent from their male contacts. These findings give further evidence for the aetiological role of C. trachomatis in non-specific urethritis and its sexual transmission. PMID:678958
Tissue engineering for human urethral reconstruction: systematic review of recent literature.
de Kemp, Vincent; de Graaf, Petra; Fledderus, Joost O; Ruud Bosch, J L H; de Kort, Laetitia M O
2015-01-01
Techniques to treat urethral stricture and hypospadias are restricted, as substitution of the unhealthy urethra with tissue from other origins (skin, bladder or buccal mucosa) has some limitations. Therefore, alternative sources of tissue for use in urethral reconstructions are considered, such as ex vivo engineered constructs. To review recent literature on tissue engineering for human urethral reconstruction. A search was made in the PubMed and Embase databases restricted to the last 25 years and the English language. A total of 45 articles were selected describing the use of tissue engineering in urethral reconstruction. The results are discussed in four groups: autologous cell cultures, matrices/scaffolds, cell-seeded scaffolds, and clinical results of urethral reconstructions using these materials. Different progenitor cells were used, isolated from either urine or adipose tissue, but slightly better results were obtained with in vitro expansion of urothelial cells from bladder washings, tissue biopsies from the bladder (urothelium) or the oral cavity (buccal mucosa). Compared with a synthetic scaffold, a biological scaffold has the advantage of bioactive extracellular matrix proteins on its surface. When applied clinically, a non-seeded matrix only seems suited for use as an onlay graft. When a tubularized substitution is the aim, a cell-seeded construct seems more beneficial. Considerable experience is available with tissue engineering of urethral tissue in vitro, produced with cells of different origin. Clinical and in vivo experiments show promising results.
The Cost of Surveillance After Urethroplasty
Zaid, Uwais B.; Hawkins, Mitchel; Wilson, Leslie; Ting, Jie; Harris, Catherine; Alwaal, Amjad; Zhao, Lee C.; Morey, Allen F.; Breyer, Benjamin N.
2015-01-01
Objectives To determine variability in urethral stricture surveillance. Urethral strictures impact quality of life and exact a large economic burden. Although urethroplasty is the gold standard for durable treatment, strictures recur in 8–18%. There are no universally accepted guidelines for post-urethroplasty surveillance. We performed a literature search to evaluate variability in surveillance protocols, analyzed costs, and reviewed performance of each commonly employed modality. Methods Medline search was performed using the keywords: “urethroplasty,” “urethral stricture,” “stricture recurrence” to ascertain commonly used surveillance strategies for stricture recurrence. We included English language manuscripts from the past 10 years with at least 10 patients, and age greater than 18. Cost data was calculated based on standard 2013 Centers for Medicare and Medicaid Services physician’s fees. Results Surveillance methods included retrograde urethrogram/voiding cystourethrogram (RUG/VCUG), cystourethroscopy, urethral ultrasound, AUA-Symptom Score, and post void residual (PVR) and urine flowmetry (UF) measurement. Most protocols call for a RUG/VCUG at time of catheter removal. Following this, UF/PVR, cystoscopy, urine culture, or a combination of UF and AUA-SS were performed at variable intervals. The first year follow-up cost of anterior urethral surgery ranged from $205 to $1,784. For posterior urethral surgery, follow-up cost for the first year ranged from $404 to $961. Conclusions Practice variability for surveillance of urethral stricture recurrence after urethroplasty leads to significant differences in cost. PMID:25819624
Jam proof closure assembly for lidded pressure vessels
Cioletti, Olisse C.
1992-01-01
An expendable closure assembly is provided for use (in multiple units) with a lockable pressure vessel cover along its rim, such as of an autoclave. This assembly is suited to variable compressive contact and locking with the vessel lid sealing gasket. The closure assembly consists of a thick walled sleeve insert for retention in the under bores fabricated in the cover periphery and the sleeve is provided with internal threading only. A snap serves as a retainer on the underside of the sleeve, locking it into an under bore retention channel. Finally, a standard elongate externally threaded bolt is sized for mating cooperation with the so positioned sleeve, whereby the location of the bolt shaft in the cover bore hole determines its compressive contact on the underlying gasket.
Heesakkers, John; Gerretsen, Reza; Izeta, Ander; Sievert, Karl-Dietrich; Farag, Fawzy
2016-02-01
The diagnosis of intrinsic sphincter deficiency (ISD) in patients with stress urinary incontinence (SUI) is not well established. We explored the possibility of applying a new tool: minimally invasive circumferential sphincter surface electromyography (CSS-EMG) to assess the muscular integrity of the urethral sphincter in patients with SUI/ISD. CSS-EMG of the urethral sphincter and urodynamic studies were performed in 44 women with SUI. A urethral pressure profile (UPP) was measured in four directions. Maximal urethral closure pressure (MUCP) <40 cm/H2 O or the presence of SUI without urethral hypermobility was used to define ISD. Twenty-one patients had urodynamic SUI, 23 had no SUI and 12 patients had ISD. The mean average rectified value (ARV) of the motor unit action potential (MUAP), an indicator of the strength of urethral rhabdosphincter, was estimated. ARV measured in the 12 o'clock quadrant during maximal contraction was the only CSS-EMG parameter that had significant predictive value for ISD. With an increase in the 12 o'clock ARV value, the likelihood of ISD decreases (Odds Ratio 0.36 95% confidence interval 0.67-0.92). In the ROC curve with ARV measured in the 12 o'clock quadrant during maximal contraction, the explained area was 0.794 (P = 0.02); implying that ARV measured at the 12 o'clock quadrant during maximal contraction was able to predict ISD significantly. Myogenic changes of the urethral sphincter that contribute to ISD can be assessed with CSS-EMG. This new concept for assessing the functionality of the female urethral sphincter may assist with better understanding of the pathophysiology, the diagnosis and the treatment of SUI. © 2014 Wiley Periodicals, Inc.
Reinnervation of Urethral and Anal Sphincters With Femoral Motor Nerve to Pudendal Nerve Transfer
Ruggieri, Michael R.; Braverman, Alan S.; Bernal, Raymond M.; Lamarre, Neil S.; Brown, Justin M.; Barbe, Mary F.
2012-01-01
Aims Lower motor neuron damage to sacral roots or nerves can result in incontinence and a flaccid urinary bladder. We showed bladder reinnervation after transfer of coccygeal to sacral ventral roots, and genitofemoral nerves (L1, 2 origin) to pelvic nerves. This study assesses the feasibility of urethral and anal sphincter reinnervation using transfer of motor branches of the femoral nerve (L2–4 origin) to pudendal nerves (S1, 2 origin) that innervate the urethral and anal sphincters in a canine model. Methods Sacral ventral roots were selected by their ability to stimulate bladder, urethral sphincter, and anal sphincter contraction and transected. Bilaterally, branches of the femoral nerve, specifically, nervus saphenous pars muscularis [Evans HE. Miller’s anatomy of the dog. Philadelphia: W.B. Saunders; 1993], were transferred and end-to-end anastomosed to transected pudendal nerve branches in the perineum, then enclosed in unipolar nerve cuff electrodes with leads to implanted RF micro-stimulators. Results Nerve stimulation induced increased anal and urethral sphincter pressures in five of six transferred nerves. Retrograde neurotracing from the bladder, urethral sphincter, and anal sphincter using fluorogold, fast blue, and fluororuby, demonstrated urethral and anal sphincter labeled neurons in L2–4 cord segments (but not S1–3) in nerve transfer canines, consistent with rein-nervation by the transferred femoral nerve motor branches. Controls had labeled neurons only in S1–3 segments. Postmortem DiI and DiO labeling confirmed axonal regrowth across the nerve repair site. Conclusions These results show spinal cord reinnervation of urethral and anal sphincter targets after sacral ventral root transection and femoral nerve transfer (NT) to the denervated pudendal nerve. These surgical procedures may allow patients to regain continence. PMID:21953679
Zehnder, Pascal; Roth, Beat; Burkhard, Fiona C; Kessler, Thomas M
2008-09-01
We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.
Thulium laser urethrotomy for urethral stricture: a preliminary report.
Wang, Linhui; Wang, Zhixiang; Yang, Bo; Yang, Qing; Sun, Yinghao
2010-09-01
The outcome of thulium laser urethrotomy for patients with urethral stricture had not been reported. The purpose of this study was to evaluate outcome of endourethrotomy with the thulium laser as a minimally invasive treatment for urethral stricture. Twenty-one consecutive patients with urethral stricture were evaluated by retrograde uroflowmetry, International Prostate Symptom Score (IPSS), and quality of life preoperatively at a single academic center. All patients were treated with thulium laser urethrotomy. All patients were followed up for 12-24 months postoperatively by uroflowmetry and by retrograde with voiding cystourethrogram every 3 months. And all patients were followed up by mailed questionnaire, including IPSS and quality of life. Retrograde endoscopic thulium laser urethrotomy was performed in all 21 patients. Most patients (N = 16; 76.2%) did not need any reintervention. Five patients developed recurrent strictures, of them two patients were treated by another laser urethrotomy, one patient was treated by open urethroplasty with buccal mucosa and the other two patients' reintervention were treated by urethral dilation. No intraoperative complications were encountered, although in 9.5% (N = 2) of patients, a urinary tract infection was diagnosed postoperatively. No gross hematuria occurred. Including two patients treated with repeat laser urethrotomy, 17(81.0%) showed good flow of urine (Q(ave)>16.0 ml/second) and adequate caliber urethra in retrograde urethrogram (RGU) 12 months after operation. Three (14.3%) patients showed narrow stream of urine (Q(ave)<8.0 ml/second) and urethral dilation was done every month or 2 months. There was one patient whose Q(ave) was between 8.0 and 16.0 ml/second. And this patient was treated by neither urethral dilation nor another laser urethrotomy. The thulium laser urethrotomy was a safe and effective minimally invasive therapeutic modality for urethral stricture. 2010 Wiley-Liss, Inc.
Husmann, D A; Rathbun, S R
2006-10-01
We reviewed the results of direct vision urethrotomy for short (less than 1 cm) penile urethral strictures following hypospadias surgery. Patients with less than 1 cm anterior penile urethral strictures located proximal to the meatus underwent direct vision urethrotomy. Based on the type of initial urethroplasty patients were randomly divided into treatment with direct vision urethrotomy vs direct vision urethrotomy plus clean intermittent catheterization for 3 months. Success was defined as absent obstructive voiding symptoms and a normal urine flow 2 years following the last patient instrumentation. Of patients with urethral strictures following hypospadias repair 44% (32) had previously undergone tubularized graft urethroplasty and 56% (40) had previously undergone flap urethroplasty, including a tubularized island flap in 18, an onlay flap in 11 and urethral plate urethroplasty in 11. Direct vision urethrotomy alone was performed in 51% of patients (37), and direct vision urethrotomy and clean intermittent catheterization were performed in 49% (35). Success with the 2 methods was similar, that is 24% (9 of 37 patients) vs 22% (8 of 35). Following direct vision urethrotomy all patients with tubularized graft urethroplasty showed failure (0 of 32). Success was noted in 11% of patients (2 of 18) with tubularized island flap urethroplasty compared to 72% (8 of 11) with onlay urethroplasty and 63% (7 of 11) with urethral plate urethroplasty (each p <0.05). The addition of clean intermittent catheterization to direct vision urethrotomy does not improve the likelihood of success. Direct vision urethrotomy for short (less than 1 cm) urethral stricture usually fails following any type of tubularized graft or flap urethroplasty but it had moderate success following onlay flap and urethral plate urethroplasties.
Ivaz, Stella L; Veeratterapillay, Rajan; Jackson, Matthew J; Harding, Christopher K; Dorkin, Trevor J; Andrich, Daniela E; Mundy, Anthony R
2016-09-01
Intermittent self-dilatation (ISD) may be recommended to reduce the risk of recurrent urethral stricture. Level one evidence to support the use of this intervention is lacking. Determine the clinical and cost-effectiveness of ISD for the management of urethral stricture disease in males. The strategy developed for the Cochrane Incontinence Review Group as a whole (last searched May 7, 2014). Randomised trials where one arm was a programme of ISD for urethral stricture. At least two independent review authors carried out trial assessment, selection, and data abstraction. Data from six trials that were pooled and collectively rated very low quality per the GRADE approach, indicated that recurrent urethral stricture was less likely in men who performed ISD than those who did not (RR 0.70, 95% CI 0.48-1.00). Two trials compared programmes of ISD but the data were not combined and neither were sufficiently robust to draw firm conclusions. Three trials compared devices for performing ISD, results from one of which were too uncertain to determine the effects of a low friction hydrophilic catheter versus a polyvinyl chloride catheter on risk of recurrent urethral stricture (RR 0.32, 95% CI 0.07 to 1.40); another did not find evidence of a difference between 1% triamcinolone gel for lubricating the ISD catheter versus water-based gel on risk of recurrent urethral stricture (RR 0.68, 95% CI 0.35 to 1.32). No trials gave cost-effectiveness or validated PRO data. ISD may decrease the risk of recurrent urethral stricture. A well-designed RCT is required to determine whether that benefit alone is sufficient to make this intervention worthwhile and in whom. Neurourol. Urodynam. 35:759-763, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Çelebi, Süleyman; Sander, Serdar; Kuzdan, Özgür; Özaydın, Seyithan; Güvenç, Ünal; Yavuz, Sevgi; Kıyak, Aysel; Demirali, Oyhan
2015-04-01
Children commonly undergo vesicograms for diagnosing vesicoureteral reflux (VUR). This requires urethral catheterization with transurethral replacement. We report misdiagnosed or related complications due to indwelling urethral catheters unintentionally placed in the ureter. From our computerized urology records over an 18-year period from January 1995 to May 2013, we retrospectively identified nine cases of 1850 vesicograms that had misdirection of a urethral catheter placed in a ureter. Foley catheters with inflating balloons were used to obtain the vesicograms. In all, 1850 vesicograms were performed (746 males, 1104 females; age 1 week to 14 years, mean age 3.8 years) using standard radiological techniques. Size 6-10 Fr indwelling urethral catheters were used, depending on the patient's age and gender. In nine cases (five females, four males), a misdirected urethral catheter was discovered in one of the ureters. The urethral catheter was in the left ureter in four patients and in the right ureter in five patients. Cystoscopic examination found ectopic ureteral openings in six patients: at the bladder neck in four and just below the bladder trigone in two. Three patients in this group with ectopic ureters were followed due a misdiagnosis of VUR. The remaining three patients had grade 3 or 4 VUR. In this group, the catheter passed into the ureter because of the enlarged ureterovesical junction. In one patient with VUR, intraparenchymal fluid leakage and transient hematuria occurred due to the rapid tension increase following the fast injection of contrast with liquid to one ureter. Although placing an indwelling urethral catheter is a relatively safe procedure, complications can occur, particularly in patients with ureterovesical anomalies, such as high-grade VUR or an ectopic ureter. Using catheters with inflating balloons can cause rapid increases in tension in the ureter, and related complications.
Martínez Montoya, Jorge A; Tascón Acevedo, Natalia M
2009-04-01
In order to evaluate the efficacy of different surgical techniques for the correction of traumatic lesions of the urethra, we performed a retrospective study in those patients, and evaluated different complications such as postsurgical stenosis of the urethra, incontinence and impotence (erectile dysfunction). A retrospective study was conducted, reviewing the clinical charts of 43 patients admitted to the San Vicente of Paul Hospital, with diagnosis of traumatic rupture of the posterior urethra from 1987 to 2007. We analyzed different demographic data, type of surgical correction, early and late complications. The average age of the patients was 7.7 years, the average follow up was 30.6 months, and all the patients were male with a posterior urethral rupture. 27 Patients underwent a primary urethral repair (63%), 13 patients underwent a cistostomy with later urologic reconstruction (30%), in 3 patients (7%) other surgical procedures were made. Overall complication rate was 39.5%. These complications were: Urethral stenosis, 26 patients (60.5%), urinary retention secondary to obstruction, 10 patients (23.3%), incontinence 10 patients (23.3%) and impotence 7 patients (16.3%). Patients treated with a primary urethral repair presented a significantly less development of infection, obstruction and stenosis, (p<0.05). Patients with pelvis fracture associated to urethral trauma had a significant higher risk of developing stenosis and impotence. (p<0.05). Both different surgical techniques compared showed a similar complication and morbidity rates in middle follow up. Each procedure should be selected according to clinical condition of the patient, the extension of the urethral damage, the associated traumatic lesions and the surgeon's expertise. In our searched patients, treated with a primary urethral repair we found a significantly less development of infection, obstruction and stenosis.
Schade, George R.; Styn, Nicholas R.; Hall, Timothy L.
2012-01-01
Abstract Background and Purpose Histotripsy is a nonthermal focused ultrasound technology that uses acoustic cavitation to homogenize tissue. Previous research has demonstrated that the prostatic urethra is more resistant to histotripsy effects than prostate parenchyma, a finding that may complicate the creation of transurethral resection of the prostate-like treatment cavities. The purpose of this study was to characterize the endoscopic appearance of the prostatic urethra during and after histotripsy treatment and to identify features that are predictive of urethral disintegration. Materials and Methods Thirty-five histotripsy treatments were delivered in a transverse plane traversing the prostatic urethra in 17 canine subjects (1–3/prostate ≥1 cm apart). Real-time endoscopy was performed in the first four subjects to characterize development of acute urethral treatment effect (UTE). Serial postprocedure endoscopy was performed in all subjects to assess subsequent evolution of UTE. Results Endoscopy during histotripsy was feasible with observation of intraurethral cavitation, allowing characterization of the real-time progression of UTE from normal to frank urethral disintegration. While acute urethral fragmentation occurred in 3/35 (8.6%) treatments, frank urethral disintegration developed in 24/35 (68.5%) within 14 days of treatment. Treating until the appearance of hemostatic pale gray shaggy urothelium was the best predictor of achieving urethral fragmentation within 14 days of treatment with positive and negative predictive values of 0.91 and 0.89, respectively. Conclusion Endoscopic assessment of the urethra may be a useful adjunct to prostatic histotripsy to help guide therapy to ensure urethral disintegration, allowing drainage of the homogenized adenoma and effective tissue debulking. PMID:22050511
Marković, B B; Marković, Z; Yachia, D; Hadzi, Djokić J
2007-01-01
A number of urethral stents made of different materials, with different time of indwelling and different designs, primarily based on the vascular stent concept, have been applied in the clinical practice so far. According to the published studies, urethral stents have justified their clinical application, however with certain limitations. Within an attempt to overcome the limitations, a covered, temporary urethral stent was initially designed by Daniel Yachie and Ijko Markovi in Allium corporation from Israel. With its triangular shape, the stent is a replica of the obstructive prostatic urethral lumen. In has been applied in a series of 14 patients with lower urinary tract symptoms caused by the obstruction at the level of the prostatic urethra. The subjects were averagely aged 77.4 +/- 5.1 years. Allium prostatic stent remained in place in the patients for 4.93 +/- 3.17 months, at the average.
Ng, Andrea; Ross, Jonathan D C
2016-01-01
Persistent or recurrent non-gonococcal urethritis has been reported to affect up to 10-20% of men attending sexual health clinics. An audit was undertaken to review the management of persistent or recurrent non-gonococcal urethritis in men presenting at Whittall Street Clinic, Birmingham, UK. Detection of Trichomonas vaginalis infection was with the newly-introduced nucleic acid amplification test. A total of 43 (8%) of 533 men treated for urethritis re-attended within three months with persistent or recurrent symptoms. Chlamydia trachomatis infection was identified in 13/40 (33%), T. vaginalis in 1/27 (4%) and Mycoplasma genitalium in 6/12 (50%). These findings suggest that the prevalence of T. vaginalis infection remains low in our clinic population and may not contribute significantly to persistent or recurrent non-gonococcal urethritis. © The Author(s) 2015.
Kovell, Robert Caleb; Terlecki, Ryan Patrick
2015-02-01
To describe the novel technique of ventral inlay substitution urethroplasty for the management of male anterior urethral stricture disease. A 58-year-old gentleman with multifocal bulbar stricture disease measuring 7 cm in length was treated using a ventral inlay substitution urethroplasty. A dorsal urethrotomy was created, and the ventral urethral plated was incised. The edges of the urethral plate were mobilized without violation of the ventral corpus spongiosum. A buccal mucosa graft was harvested and affixed as a ventral inlay to augment the caliber of the urethra. The dorsal urethrotomy was closed over a foley catheter. No intraoperative or postoperative complications occurred. Postoperative imaging demonstrated a widely patent urethra. After three years of follow-up, the patient continues to do well with no voiding complaints and low postvoid residuals. Ventral inlay substitution urethroplasty appears to be a safe and feasible technique for the management of bulbar urethral strictures.
Postpubertal genitourinary function following posterior urethral disruptions in children.
Boone, T B; Wilson, W T; Husmann, D A
1992-10-01
A total of 24 boys sustaining a simultaneous pelvic fracture and posterior urethral disruption was observed from the time of injury through puberty. Average length of followup was 6 years. In contrast to the adult, in whom the urethra is invariably injured at the prostatomembranous junction, the posterior urethral disruptions in the prepubertal patient were at 3 distinct locations: 1) supraprostatic in 4 patients, 2) transprostatic in 4 and 3) prostatomembranous in 16. Prolonged followup through puberty in these children revealed that the frequency of complications was significantly higher for urethral injuries proximal to the prostatomembranous region compared to those at this latter site: impotence 75% versus 31%, intractable strictures following repairs 75% versus 12% and urinary incontinence 25% versus 0%. In summary, the prognosis of children who sustain a posterior urethral disruption should be based on the location of the injury and must remain guarded until the individual attains a postpubertal status.
Medical Surveillance Monthly Report (MSMR). Volume 15, Number 10, December 2008
2008-12-01
gonococcal (NGU). Reporting locations Arthropod-borne Sexually transmitted Environmental Lyme disease Malaria Chlamydia Gonorrhea Syphilis‡ Urethritis§ Cold...gonococcal (NGU). Reporting location Arthropod-borne Sexually transmitted Environmental Lyme disease Malaria Chlamydia Gonorrhea Syphilis‡ Urethritis...Lyme disease Malaria Chlamydia Gonorrhea Syphilis‡ Urethritis§ Cold Heat 2007 2008 2007 2008 2007 2008 2007 2008 2007 2008 2007 2008 2007 2008 2007
2013-06-04
Metastatic Transitional Cell Cancer of the Renal Pelvis and Ureter; Recurrent Bladder Cancer; Recurrent Transitional Cell Cancer of the Renal Pelvis and Ureter; Recurrent Urethral Cancer; Stage III Bladder Cancer; Stage III Urethral Cancer; Stage IV Bladder Cancer; Stage IV Urethral Cancer; Transitional Cell Carcinoma of the Bladder; Ureter Cancer
Y-type urethral duplication: an unusual variant of a rare anomaly.
Kumaravel, S; Senthilnathan, R; Sankkarabarathi, C; Bagdi, R K; Soundararajan, S; Prasad, N
2004-12-01
Urethral duplications are rare anomalies. We present a 3-year-old continent boy passing urine since birth per anus while voiding from penis. Micturating cystourethrogram, retrograde urethrogram and cystoscopy revealed a Y connection between the posterior urethra and anal canal. The accessory channel was excised by a perineal approach. Histopathology revealed that the tract was lined by transitional epithelium, proving that it was indeed a case of urethral duplication; hence, we suggest that all urethroanal fistulas are not variants of anorectal malformations. Certain of these fistulas should be considered as variants of Y-type urethral duplication even if the orthotopic urethra is normal.
A simple technique to facilitate treatment of urethral strictures with optical internal urethrotomy.
Stamatiou, Konstantinos; Papadatou, Aggeliki; Moschouris, Hippocrates; Kornezos, Ioannis; Pavlis, Anargiros; Christopoulos, Georgios
2014-01-01
Urethral stricture is a common condition that can lead to serious complications such as urinary infections and renal insufficiency secondary to urinary retention. Treatment options include catheterization, urethroplasty, endoscopic internal urethrotomy, and dilation. Optical internal urethrotomy offers faster recovery, minimal scarring, and less risk of infection, although recurrence is possible. However, technical difficulties associated with poor visualization of the stenosis or of the urethral lumen may increase procedural time and substantially increase the failure rates of internal urethrotomy. In this report we describe a technique for urethral catheterization via a suprapubic, percutaneous approach through the urinary bladder in order to facilitate endoscopic internal urethrotomy.
The Association of Congenital Urethral Duplication and Double Megalourethra
Uçar, Murat; Karagözlü Akgül, Ahsen; Kılıç, Nizamettin; Balkan, Emin
2017-01-01
Background: Urethral duplication and megalourethra are rare urethral anomalies. However, the concomitance of urethral duplication and double megalourethra has not been reported previously. Case Report: A newborn was presented with penile swelling during voiding. Physical examination revealed a retractable foreskin and two external meatus of a double urethra. Retrograde urethrography demonstrated two complete megalourethras. Urethro-urethrostomy and urethroplasty were performed when the patient was 10 months old. The patient was followed up for one year without any urinary problems and has good cosmetics and urinary continence. Conclusion: The concomitance of these two rare anomalies and more importantly its surgical treatment makes this case report unique and valuable. PMID:29215339
Hypothyroidism impairs somatovisceral reflexes involved in micturition of female rabbits.
Sánchez-García, Octavio; López-Juárez, Rhode; Rodríguez-Castelán, Julia; Corona-Quintanilla, Dora L; Martínez-Gómez, Margarita; Cuevas-Romero, Estela; Castelán, Francisco
2018-04-17
To determine the impact of hypothyroidism on the bladder and urethral functions as well as in the activation of the pubococcygeous (Pcm) and bulbospongiosus (Bsm) during micturition. Age-matched control and methimazole-induced hypothyroid female rabbits were used to simultaneously record cystometrograms, urethral pressure, and the reflex activation of Pcm and Bsm during the induced micturition. Urodynamic and urethral variables were measured. Activation or no activation of the Pcm and Bsm during the storage and voiding phases of micturition were categorized as 1 or 0. Significant differences (P ≤ 0.05) between control and hypothyroid groups were determined with unpaired Student-t or Mann-Whitney tests. One-month induced hypothyroidism increased the residual volume and threshold pressure while the opposite was true for the voided volume, maximal pressure, and voiding efficiency. Urethral pressure was also affected as supported by a notorious augmentation of the urethral resistance, among other changes in the rest of measured variables. Hypothyroidism also affected the reflex activation of the Pcm in the voiding phase of micturition. Our findings demonstrate hypothyroidism impairs the bladder and, urethral functions, and reflex activation of Pcm and Bsm affecting the micturition in female rabbits. © 2018 Wiley Periodicals, Inc.
Temporary vesicostomy-assisted urethroplasty for recurrent obliterated posterior urethral stricture.
Liu, Jui-Ming; Wang, Ta-Min; Chiang, Yang-Jen; Chen, Hsiao-Wen; Chu, Sheng-Hsien; Liu, Kuan-Lin; Lin, Kuo-Jen
2012-01-01
We report the outcomes of temporary vesicostomy- assisted anastomotic urethroplasty in patients with recurrent obliterated posterior urethral stricture. A review of the medical records identified 12 men (mean age 35.8 years) who had undergone anastomotic urethroplasty for recurrent obliterated posterior stricture. Preoperative evaluation of the urethral defect included a simultaneous retrograde urethrogram and cystogram. The mean estimated preoperative radiographic length of the urethral disruption was 4.25 cm. All patients underwent 1-stage bulboprostatic anastomotic repair which was assisted by an intraoperative temporary vesicostomy. The initial objective success rate was 83%. The mean follow-up was 22 months. Voiding cystourethrography performed postoperatively demonstrated a wide, patent anastomosis in all but two cases. Urethroscopy performed 1 month after surgery revealed a patent anastomosis with normal urethral mucosa in all but two patients. The mean peak flow rate at the last follow-up visit was 16.3 ml/s. Two patients developed an anastomotic stricture 6 weeks after surgery that was successfully treated by direct visual internal urethrotomy. Finally, all patients had a patent urethra after salvage treatment postoperatively. An open 1-stage temporary vesicostomy- assisted urethroplasty for recurrent obliterated posterior urethral stricture provides satisfactory outcomes and minimal morbidities.
Pelvic fracture-associated urethral injuries in girls: experience with primary repair.
Dorairajan, Lalgudi N; Gupta, Harendra; Kumar, Santosh
2004-07-01
To present our experience with four urethral injuries in females accompanying a pelvic fracture, managed with primary repair or realignment of the urethra. There were three teenage girls and one adult (22 years old). All the patients had complete urethral injuries associated with a pelvic fracture from accidents. They were managed by immediate suprapubic cystostomy followed by repair or realignment of the urethra over a catheter on the same day. The catheter was removed after 3 weeks and a voiding cysto-urethrogram taken. Thereafter they were followed with regular urethral calibration. All patients voided satisfactorily with a good stream; three were fully continent and the fourth had transient stress urinary incontinence. One patient needed dilatation at 2 months and another visual internal urethrotomy at 5 months. At a mean (range) follow-up of 33 (9-60) months all the patients had a normal voiding pattern and were continent; none developed vaginal stenosis. Primary repair of the urethra, and if that is impossible, simple urethral realignment over a catheter, is the procedure of choice for managing female urethral injury associated with a pelvic fracture. The procedure has the additional advantage of reducing the risk of vaginal stenosis.
[Urethral pain syndrome: fact or fiction--an update].
Dreger, N M; Degener, S; Roth, S; Brandt, A S; Lazica, D A
2015-09-01
Urethral pain syndrome is a symptom complex including dysuria, urinary urgency and frequency, nocturia and persistent or intermittent urethral and/or pelvic pain in the absence of proven infection. These symptoms overlap with several other conditions, such as interstitial cystitis bladder pain syndrome and overactive bladder. Urethral pain syndrome may occur in men but is more frequent in women. The exact etiology is unknown but infectious and psychogenic factors, urethral spasms, early interstitial cystitis, hypoestrogenism, squamous metaplasia as well as gynecological risk factors are discussed. These aspects should be ruled out or confirmed in the diagnostic approach. Despite the assumption of a multifactorial etiology, pathophysiologically there is a common pathway: dysfunctional epithelium of the urethra becomes leaky which leads to bacterial and abacterial inflammation and ends in fibrosis due to the chronic impairment. The therapeutic approach should be multimodal using a trial and error concept: general treatment includes analgesia, antibiotics, alpha receptor blockers and muscle relaxants, antimuscarinic therapy, topical vaginal estrogen, psychological support and physical therapy. In cases of nonresponding patients intravesical and/or surgical therapy should be considered. The aim of this review is to summarize the preliminary findings on urethral pain syndrome and to elucidate the diagnostic and therapeutic options.
NASA Technical Reports Server (NTRS)
Gheen, Darrell
2007-01-01
A tool makes a cut perpendicular to the cylindrical axis of a core hole at a predetermined depth to free the core at that depth. The tool does not damage the surrounding material from which the core was cut, and it operates within the core-hole kerf. Coring usually begins with use of a hole saw or a hollow cylindrical abrasive cutting tool to make an annular hole that leaves the core (sometimes called the plug ) in place. In this approach to coring as practiced heretofore, the core is removed forcibly in a manner chosen to shear the core, preferably at or near the greatest depth of the core hole. Unfortunately, such forcible removal often damages both the core and the surrounding material (see Figure 1). In an alternative prior approach, especially applicable to toxic or fragile material, a core is formed and freed by means of milling operations that generate much material waste. In contrast, the present tool eliminates the damage associated with the hole-saw approach and reduces the extent of milling operations (and, hence, reduces the waste) associated with the milling approach. The present tool (see Figure 2) includes an inner sleeve and an outer sleeve and resembles the hollow cylindrical tool used to cut the core hole. The sleeves are thin enough that this tool fits within the kerf of the core hole. The inner sleeve is attached to a shaft that, in turn, can be attached to a drill motor or handle for turning the tool. This tool also includes a cutting wire attached to the distal ends of both sleeves. The cutting wire is long enough that with sufficient relative rotation of the inner and outer sleeves, the wire can cut all the way to the center of the core. The tool is inserted in the kerf until its distal end is seated at the full depth. The inner sleeve is then turned. During turning, frictional drag on the outer core pulls the cutting wire into contact with the core. The cutting force of the wire against the core increases with the tension in the wire and, hence, with the frictional drag acting on the outer sleeve. As the wire cuts toward the center of the core, the inner sleeve rotates farther with respect to the outer sleeve. Once the wire has cut to the center of the core, the tool and the core can be removed from the hole. The proper choice of cutting wire depends on the properties of the core material. For a sufficiently soft core material, a nonmetallic monofilament can be used. For a rubber-like core material, a metal wire can be used. For a harder core material, it is necessary to use an abrasive wire, and the efficiency of the tool can be increased greatly by vacuuming away the particles generated during cutting. For a core material that can readily be melted or otherwise cut by use of heat, it could be preferable to use an electrically heated cutting wire. In such a case, electric current can be supplied to the cutting wire, from an electrically isolated source, via rotating contact rings mounted on the sleeves.
Mauriello, Claudio; Chouillard, Elie; d'alessandro, Antonio; Marte, Gianpaolo; Papadimitriou, Argyri; Chahine, Elias; Kassir, Radwan
2018-04-16
Evaluate the efficacy of single-port sleeve gastrectomy (SPSG) and then compare it to a less-invasive sleeve approach (three-port) (3PSG) according to a propensity score (PS) matching analysis. We analyzed all patients who underwent SG through a three-port or a single-port laparoscopic approach. After 2 years, the follow-up was completed in 84% patients treated with 3PSG and 95% patients of the SPSG group. Excess weight loss (EWL) was comparable for the first year of follow-up within the two groups except for the controls at 3 months in which the SPSG group showed a higher EWL (p = 0.0243). We demonstrated the efficacy of SPSG in bariatric surgery even compared to another, less invasive, laparoscopic SG approach (three-port).
PWR integral tie plate and locking mechanism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flora, B.S.; Osborne, J.L.
1980-08-26
A locking mechanism for securing an upper tie plate to the tie rods of a nuclear fuel bundle is described. The mechanism includes an upper tie plate assembly and locking sleeves fixed to the ends of the tie rods. The tie plate is part of the upper tie plate assembly and is secured to the fuel bundle by securing the entire upper tie plate assembly to the locking sleeves fixed to the tie rods. The assembly includes, in addition to the tie plate, locking nuts for engaging the locking sleeves, retaining sleeves to operably connect the locking nuts to themore » assembly, a spring biased reaction plate to restrain the locking nuts in the locked position and a means to facilitate the removal of the entire assembly as a unit from the fuel bundle.« less
The management of amputations of the leg using a new rigid foam plaster for prosthetic fitting.
Hölter, W; Echterhoff, M; Blömer, A; Verfürden, H
1980-01-01
This paper describes the use of a rigid polyurethane foam to construct a stump socket for immediate or early prosthetic fitting in 15 patients with amputation through the leg. The foam plaster is poured into a prepared cotton sleeve, with a zip incorporated, and rolled out to a layer 4 mm thick. The filled sleeve is put around the stump and the zip closed, moulding the sleeve firmly to the stump. The closed sleeve hardens into a rigid polyurethane shell within 20 min. Aferwards the skeletal prosthetic components are fixed with the same rigid foam. The polyurethane foam socket is quickly and cleanly prepared, only one third of the weight of a plaster of Paris cast and is easily removed by means of the zip, allowing access to the stump.
Wigner, E.P.; Young, G.J.
1958-10-14
A method is presented for loading and unloading rod type fuel elements of a neutronic reactor of the heterogeneous, solld moderator, liquid cooled type. In the embodiment illustrated, the fuel rods are disposed in vertical coolant channels in the reactor core. The fuel rods are loaded and unloaded through the upper openings of the channels which are immersed in the coolant liquid, such as water. Unloading is accomplished by means of a coffer dam assembly having an outer sleeve which is placed in sealing relation around the upper opening. A radiation shield sleeve is disposed in and reciprocable through the coffer dam sleeve. A fuel rod engaging member operates through the axial bore in the radiation shield sleeve to withdraw the fuel rod from its position in the reactor coolant channel into the shield, the shield snd rod then being removed. Loading is accomplished in the reverse procedure.
Transpiring purging access probe for particulate laden or hazardous environments
VanOsdol, John G
2013-12-03
An access probe for remote-sensing access through a viewing port, viewing volume, and access port into a vessel. The physical boundary around the viewing volume is partially formed by a porous sleeve lying between the viewing volume and a fluid conduit. In a first mode of operation, a fluid supplied to the fluid conduit encounters the porous sleeve and flows through the porous material to maintain the viewing volume free of ash or other matter. When additional fluid force is needed to clear the viewing volume, the pressure of the fluid flow is increased sufficiently to slidably translate the porous sleeve, greatly increasing the flow into the viewing volume. The porous sleeve is returned to position by an actuating spring. The access probe thereby provides for alternate modes of operation based on the pressure of an actuating fluid.
Composite drill pipe and method for forming same
Leslie, James C; Leslie, II, James C; Heard, James; Truong, Liem; Josephson, Marvin
2014-04-15
Metal inner and outer fittings configured, the inner fitting configured proximally with an external flange and projecting distally to form a cylindrical barrel and stepped down-in-diameter to form an abutment shoulder and then projecting further distally to form a radially inwardly angled and distally extending tapered inner sleeve. An outer sleeve defining a torque tube is configured with a cylindrical collar to fit over the barrel and is formed to be stepped up in diameter in alignment with the first abutment shoulder to then project distally forming a radially outwardly tapered and distally extending bonding surface to cooperate with the inner sleeve to cooperate with the inner sleeve in forming a annular diverging bonding cavity to receive the extremity of a composite pipe to abut against the abutment shoulders and to be bonded to the respective bonding surfaces by a bond.
Kizilcik, Nurcan; Koner, Ozge
2018-05-12
The purpose of the study was to investigate the effect of magnesium sulfate on pain management for pain after sleeve gastrectomy operation. A prospective, randomized, placebo-controlled clinical study. University hospital. Eighty patients undergoing sleeve gastrectomy. Visual analog scale for the evaluation of pain, sedation score, mean arterial pressure, heart rate, and total analgesic consumption was recorded. Serum magnesium levels were determined before the operation, at the end of the operation, and at 24 h. There were no significant differences between the groups with respect to demographics, and sedation scores. Cumulative morphine consumption and pain scores were found to be higher in the control group than the magnesium group. Perioperative use of magnesium sulfate reduced postoperative pain and opioid consumption in obese patients undergoing sleeve gastrectomy operations.
Management Options for Twisted Gastric Tube after Laparoscopic Sleeve Gastrectomy.
Abd Ellatif, Mohamed E; Abbas, Ashraf; El Nakeeb, Ayman; Magdy, Alaa; Salama, Asaad F; Bashah, Moataz M; Dawoud, Ibrahim; Gamal, Maged Ali; Sargsyan, Davit
2017-09-01
This study aims to determine the incidence, etiology, and management options for symptomatic gastric obstruction caused by axially twisted sleeve gastrectomy. In this retrospective study, we reviewed medical charts of all morbidly obese patients who underwent laparoscopic sleeve gastrectomy. Patients who developed gastric obstruction symptoms and were diagnosed with twisted sleeve gastrectomy were identified and included in this study. From October 2005 to December 2015, there are 3634 morbidly obese patients who underwent laparoscopic sleeve gastrectomy (LSG). Eighty-six (2.3%) patients developed symptoms of gastric obstruction. Forty-five (1.23%) patients were included in this study. The mean time of presentation was 59.8 days after surgery. Upper GI contrast study was done routinely, and it was positive for axial twist in 37 (82%) patients. Abdominal CT with oral and IV contrast was done in eight (18%) when swallow study was equivocal. Endoscopic treatment was successful in 43 patients (95.5%). Sixteen patients were successfully managed by endoscopic stenting, and 29 patients had balloon dilation. The average numbers of dilation sessions were 1.7. Out of these 29 patients, 18 responded well to a single session of dilatation and did not require any further dilatation sessions. Two patients who failed to respond to three subsequent sessions of balloon dilation underwent laparoscopic adhesiolysis and gastropexy. Endoscopic stenting is an effective tool in management of axial rotation of sleeved stomach. Balloon dilation can also be effective in selected cases. Few cases might require laparoscopic adhesiolysis and gastropexy.
Kafalı, Mehmet Ertuğrul; Şahin, Mustafa; Ece, İlhan; Acar, Fahrettin; Yılmaz, Hüseyin; Alptekin, Hüsnü; Ateş, Leyla
2017-01-01
The objective of this study was to evaluate patients who underwent laparoscopic Roux-en-Y gastric bypass and laparoscopic sleeve gastrectomy in terms of weight loss, metabolic parameters, and postoperative complications. Data on patients who underwent laparoscopic Roux-en-Y gastric bypass and laparoscopic sleeve gastrectomy with a diagnosis of morbid obesity between January 2012 and June 2014 were retrospectively evaluated. Patients were compared in terms of age, sex, body mass index, duration of operation, American Society of Anesthesiologists score, perioperative complications, length of hospital stay, and long term follow-up results. During the study period, 91 patients (45 laparoscopic Roux-en-Y gastric bypass and 46 laparoscopic sleeve gastrectomy) underwent bariatric surgery. There was no difference between the two groups in terms of preoperative patient characteristics. Both groups showed statistically significant weight loss and improvement in co-morbidities when compared with the preoperative period. Weight loss and improvement in metabolic parameters were similar in both groups. The duration of operation and hospital stay was longer in the laparoscopic Roux-en-Y gastric bypass group. Furthermore, the rate of total complications was significantly lower in the laparoscopic sleeve gastrectomy group. Laparoscopic sleeve gastrectomy is a safe and effective method with a significantly lower complication rate and length of hospital stay than laparoscopic Roux-en-Y gastric bypass, with similar improvement rates in metabolic syndrome.
Anterior Urethral Valve: A Rare But an Important Cause of Infravesical Urinary Tract Obstruction.
Parmar, Jitendra P; Mohan, Chander; Vora, Maulik P
2016-01-01
Urethral valves are infravesical congenital anomalies, with the posterior urethral valve (PUV) being the most prevalent one. Anterior urethral valve (AUV) is a rare but a well-known congenital anomaly. AUV and diverticula can cause severe obstruction, whose repercussions on the proximal urinary system can be important. Few cases have been described; both separately and in association with urethral diverticulum. The presentation of such a rare but important case led us to a report with highlighting its classic imaging features. We present a case report of AUV with lower urinary tract symptoms in a 6-year-old boy with complaints of a poor stream of urine and strain to void. Unique findings were seen on Retrograde Urethrography (RGU) and Voiding Cysto-Urethrography (VCUG), i.e. linear incomplete filling defect in the penile urethra and associated mild dilatation of the anterior urethra ending in a smooth bulge. On cysto-urethroscopy the anterior urethral valve was confirmed and fulguration was done. Congenital anterior urethral valve is an uncommon but important cause of infravesical lower urinary tract obstruction that is more common in male urethra. It can occur as an isolated AUV or in association with diverticulum and VATER anomalies. Early diagnosis and management of this rare condition is very important to prevent further damage, infection and vesicoureteral reflux. AUV may be associated with other congenital anomalies of the urinary system; therefore a full evaluation of the urinary system is essential.
Hosseini, Seyed Jali; Kaviani, Ali; Vazirnia, Ali Reza
2008-01-01
We studied the safety and efficacy of flexible cystoscopy-guided internal urethrotomy in the management of obliterative urethral strictures. Forty-three flexible cystoscopy-guided internal urethrotomies were performed between 1999 and 2005. The indication for the procedure was nearly blinded bulbar or membranous urethral strictures not longer than 1 cm that would not allow passage of guide wire. Candidates were those who refused or were unable to undergo urtheroplasty. By monitoring any impression of the urethrotome on the monitor through the flexible cystoscope, we were able to do under-vision urethrotomy. All of the patients were started clean intermittent catheterization afterwards which was tapered over the following 6 months. Follow-up continued for 24 months after the last internal urethrotomy. Seventeen patients were younger than 65 years with a history of failed posterior urethroplasty, and 26 were older than 65 with poor cardiopulmonary conditions who had bulbar urethral stricture following straddle or iatrogenic injuries. Urethral stricture stabilized in 16 patients (37.2%) with a single session of urethrotomy and in 17 (39.5%) with 2 urethrotomies. Overall, urethral stricture stabilized in 76.7% of patients with 1 or 2 internal urethrotomies within 24 months of follow-up. No severe complication was reported. Flexible cystoscopy-guided internal urethrotomy is a simple, safe, and under-vision procedure in obliterative urethral strictures shorter than 1 cm. It can be an ideal option for patients who do not accept posterior urethroplasty or are in a poor cardiopulmonary condition that precludes general anesthesia.
Dorsal inlay buccal mucosal graft (Asopa) urethroplasty for anterior urethral stricture.
Marshall, Stephen D; Raup, Valary T; Brandes, Steven B
2015-02-01
Asopa described the inlay of a graft into Snodgrass's longitudinal urethral plate incision using a ventral sagittal urethrotomy approach in 2001. He claimed that this technique was easier to perform and led to less tissue ischemia due to no need for mobilization of the urethra. This approach has subsequently been popularized among reconstructive urologists as the dorsal inlay urethroplasty or Asopa technique. Depending on the location of the stricture, either a subcoronal circumferential incision is made for penile strictures, or a midline perineal incision is made for bulbar strictures. Other approaches for penile urethral strictures include the non-circumferential penile incisional approach and a penoscrotal approach. We generally prefer the circumferential degloving approach for penile urethral strictures. The penis is de-gloved and the urethra is split ventrally to exposure the stricture. It is then deepened to include the full thickness of the dorsal urethra. The dorsal surface is made raw and grafts are fixed on the urethral surface. Quilting sutures are placed to further anchor the graft. A Foley catheter is placed and the urethra is retubularized in two layers with special attention to the staggering of suture lines. The skin incision is then closed in layers. We have found that it is best to perform an Asopa urethroplasty when the urethral plate is ≥1 cm in width. The key to when to use the dorsal inlay technique all depends on the width of the urethral plate once the urethrotomy is performed, stricture etiology, and stricture location (penile vs. bulb).
Management of the stricture of fossa navicularis and pendulous urethral strictures
Singh, Shrawan K.; Agrawal, Santosh K.; Mavuduru, Ravimohan S.
2011-01-01
Objective: Management of distal anterior urethral stricture is a common problem faced by practicing urologists. Literature on urethral stricture mainly pertains to bulbar urethral stricture and pelvic fracture urethral distraction defect. The present article aims to review the management of the strictures of fossa navicularis and pendulous urethra. Materials and Methods: The literature in English language was searched from the National Library of Medicine database, using the appropriate key words for the period 1985-2010. Out of 475 articles, 115 were selected for the review based on their relevance to the topic. Results: Etiology of stricture is shifting from infective to inflammatory and iatrogenic causes. Stricture of fossa navicularis is most often caused by lichen sclerosus et atrophicus and instrumentation. Direct visual internal urethrotomy is limited to selected cases in the management of pendulous urethral stricture. With experience and identification of various prognostic factors, conservative management by dilatation and internal urethrotomy is being replaced by various reconstructive procedures, using skin flaps and grafts with high success rates. Single-stage urethroplasty is preferred over the 2-stage procedure as the latter disfigures the penis and poses sexual problems temporarily. Conclusions: Flaps or grafts are useful for single-stage reconstruction of fossa navicularis and pendulous urethral strictures. The buccal and lingual mucosa serves as a preferred resource material for providing the inner lining of the urethra. Off-the-shelf materials, such as acellular collagen matrix, are promising. PMID:22022062
Treatment of Overactive Bladder Syndrome with Urethral Calibration in Women
Sato, Renee L; Matsuura, Grace HK; Wei, David C; Chen, John J
2013-01-01
Our objective was to determine whether urethral calibration with Walther's urethral sounds may be an effective treatment for overactive bladder syndrome. The diagnosis of overactive bladder syndrome is a clinical one based on the presence of urgency, with or without urge incontinence, and is usually accompanied by frequency and nocturia in the absence of obvious pathologic or metabolic disease. These symptoms exert a profound effect on the quality of life. Pharmacologic treatment is generally used to relieve symptoms, however anticholinergic medications may be associated with several undesirable side effects. There are case reports of symptom relief following a relatively quick and simple office procedure known as urethral dilation. It is hypothesized that this may be an effective treatment for the symptoms of overactive bladder. Women with clinical symptoms of overactive bladder were evaluated. Eighty-eight women were randomized to either urethral calibration (Treatment), or placebo (Control) treatment. Women's clinical outcomes at two and eight weeks were assessed and compared between the two treatment arms. Eight weeks after treatment, 31.1% (n=14) of women who underwent urethral calibration were responsive to the treatment versus 9.3% (n=4) of the Control group. Also, 51.1% (n=23) of women within the Treatment group showed at least a partial response versus 20.9% (n=9) of the Control group. Our conclusion is that Urethral calibration significantly improves the symptoms of overactive bladder when compared to placebo and may be an effective alternative treatment method. PMID:24167769
Acquired urethral obstruction in New World camelids: 34 cases (1995-2008).
Duesterdieck-Zellmer, K F; Van Metre, D C; Cardenas, A; Cebra, C K
2014-08-01
Document the clinical features, short- and long-term outcomes and prognostic factors in New World camelids with acquired urethral obstruction. Retrospective case study. Case data from medical records of 34 New World camelids presenting with acquired urethral obstruction were collected and follow-up information on discharged patients was obtained. Associations with short- and long-term survival were evaluated using Wilcoxon rank-sum tests, exact-logistic regressions and Kaplan-Meier survival curves. Of the 34 New World camelids 23 were intact males and 11 were castrated; 4 animals were euthanased upon presentation, 7 were treated medically and 23 surgically, including urethrotomy, bladder marsupialisation, tube cystostomy alone or combined with urethrotomy, urethrostomy or penile reefing. Necrosis of the distal penis was found in 4 animals and all were short-term non-survivors. Short-term survival for surgical cases was 65%, and 57% for medical cases. Incomplete urethral obstruction at admission and surgical treatment were associated with increased odds of short-term survival. Of 14 records available for long-term follow-up, 6 animals were alive and 8 were dead (median follow-up 4.5 years, median survival time 2.5 years). Recurrence of urethral obstruction was associated with long-term non-survival. Surgically treated New World camelids with incomplete urethral obstruction have the best odds of short-term survival and those with recurrence of urethral obstruction have a poor prognosis for long-term survival. © 2014 Australian Veterinary Association.
What is the relationship between free flow and pressure flow studies in women?
Duckett, Jonathan; Cheema, Katherine; Patil, Avanti; Basu, Maya; Beale, Sian; Wise, Brian
2013-03-01
The relationship between free flow (FFS) and pressure flow (PFS) voiding studies remains uncertain and the effect of a urethral catheter on flow rates has not been determined. The relationship between residuals obtained at FF and PFS has yet to be established. This was a prospective cohort study based on 474 consecutive women undergoing cystometry using different sized urethral catheters at different centres. FFS and PFS data were compared for different conditions and the relationship of residuals analysed for FFS and PFS. The null hypothesis was that urethral catheters do not produce an alteration in maximum flow rates for PFS and FF studies. Urethral catheterisation results in lower flow rates (p < 0.01) and this finding is confirmed when flows are corrected for voided volume (p < 0.01). FFS and PFS maximum flow rates are lower in women with DO than USI (p < 0.01). A 6-F urethral catheter does not have a significantly greater effect than a 4.5-F urethral catheter. A mathematical model can be applied to transform FFS to PFS flow rates and vice versa. There was no significant difference between the mean residuals of the two groups (FFS vs PFS-two-tailed t = 0.54, p = 0.59). Positive residuals in FFS showed a good association with positive residuals in the PFS (r = 0.53, p < 0.01) Urethral catheterisation results in lower maximum flow rates. The relationship can be compared mathematically. The null hypothesis can be rejected.
Medical Surveillance Monthly Report (MSMR). Volume 16, Number 2, February 2009
2009-02-01
Urethritis, non-gonococcal (NGU). Reporting location Arthropod-borne Sexually transmitted Environmental Lyme disease Malaria Chlamydia Gonorrhea Syphilis...transmitted Environmental Lyme disease Malaria Chlamydia Gonorrhea Syphilis‡ Urethritis§ Cold Heat 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 2008...Environmental Lyme disease Malaria Chlamydia Gonorrhea Syphilis‡ Urethritis§ Cold Heat 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 2008
Common Pediatric Urological Disorders
Robson, Wm. Lane M.; Leung, Alexander K.C.; Boag, Graham S.
1991-01-01
The clinical and radiological presentations of 12 pediatric urological disorders are described. The described disorders include pyelonephritis, vesicoureteral reflux, ureteropelvic obstruction, ureterovesical obstruction, ectopic ureterocele, posterior urethral valves, multicystic dysplastic kidney, polycystic kidney disease, ectopic kidney, staghorn calculi, urethral diverticulum, and urethral meatal stenosis. ImagesFigure 1-2Figure 3Figure 3Figure 4Figure 5Figure 6-7Figure 8-9Figure 10Figure 11-12 PMID:21229068
Posterior urethral stricture repair following trauma and pelvic fracture.
Rios, Emilio; Martinez-Piñeiro, Luis; Álvarez-Maestro, Mario
2014-01-01
Posterior urethral injuries typically arise in the context of a pelvic fracture.The correct and appropriate initial treatment of associated urethral rupture is critical to the proper healing of the injury. In this paper, we provide a comprehensive review of the literature with special emphasis on the various treatments available: open or endoscopic primary realignment, immediate or delayed urethroplasty after suprapubic cystostomy, and delayed optical urethrotomy.
Welding fixture for nuclear fuel pin cladding assemblies
Oakley, David J.; Feld, Sam H.
1986-01-01
A welding fixture for locating a driver sleeve about the open end of a nuclear fuel pin cladding. The welding fixture includes a holder provided with an open cavity having shoulders for properly positioning the driver sleeve, the end cap, and a soft, high temperature resistant plastic protective sleeve that surrounds a portion of the end cap stem. Ejected contaminant particles spewed forth by closure of the cladding by pulsed magnetic welding techniques are captured within a contamination trap formed in the holder for ultimate removal and disposal of contaminating particles along with the holder.
1994-05-01
utilizes drill bits and tubing to cut through the soil. Unlike the auger method, a slurry mixture is used to keep the drill bit clean and assist in...is applied. In the sleeve pipe method, or also called tube -a-manchette, the sleeve pipe is installed in the grout hole, and sealed in place with a...acts as a one-way valve. allowing grout out of the pipe, but not back into the sleeve. A grouting tube with double packer is used to inject the grout
Surgical correction of bladder neck contracture following prostate cancer treatment.
Bugeja, Simon; Andrich, Daniela E; Mundy, Anthony R
2014-01-01
The surgical and non-surgical treatment of localised prostate cancer may be complicated by bladder neck contractures, prostatic urethral stenoses and bulbomembranous urethral strictures. In general, such complications following radical prostatectomy are less extensive, easier to treat and associated with a better outcome and more rapid recovery than the same complications following radiotherapy, high-intensity focussed ultrasound and cryotherapy. Treatment options range from minimally invasive endoscopic procedures to more complex and specialised open surgical reconstruction.In this chapter the surgical management of bladder neck contractures following the treatment of prostate cancer is described together with the management of prostatic urethral stenoses and bulbomembranous urethral strictures, given the difficulty in distinguishing them from one another clinically.
Soccorso, G; Thyagarajan, M S; Murthi, G V; Sprigg, A
2008-02-01
Ano-rectal malformations (ARM) in the male patient may be associated with a fistulous communication between the rectum and urethra. Pre-operative radiological assessment is important to delineate (a) the presence and level of the fistula, (b) the anatomy of the posterior urethra and (c) any anomalies in adjacent structures. Bladder catheterisation can be technically difficult when performing an MCUG and distal loopogram in such patients. This can be due to urethral stricture, tortuous or kinked urethra or preferential passage of catheter into a large fistula and leads to an inadequate study. We describe a "double urethral catheter technique" to enable urethral catheterisation when the fistula is large.
2018-05-18
Metastatic Bladder Urothelial Carcinoma; Metastatic Renal Pelvis Urothelial Carcinoma; Metastatic Ureter Urothelial Carcinoma; Metastatic Urethral Urothelial Carcinoma; Metastatic Urothelial Carcinoma; Recurrent Bladder Urothelial Carcinoma; Recurrent Renal Pelvis Urothelial Carcinoma; Recurrent Ureter Urothelial Carcinoma; Recurrent Urethral Urothelial Carcinoma; Stage III Bladder Cancer AJCC v8; Stage III Renal Pelvis Cancer AJCC v8; Stage III Ureter Cancer AJCC v8; Stage III Urethral Cancer AJCC v8; Stage IV Bladder Cancer AJCC v8; Stage IV Renal Pelvis Cancer AJCC v8; Stage IV Ureter Cancer AJCC v8; Stage IV Urethral Cancer AJCC v8; Stage IVA Bladder Cancer AJCC v8; Stage IVB Bladder Cancer AJCC v8
Saaby, Marie-Louise
2014-02-01
Stress urinary incontinence (SUI) occurs when the bladder pressure exceeds the urethral pressure in connection with physical effort or exertion or when sneezing or coughing and depends both on the strength of the urethral closure function and the abdominal pressure to which it is subjected. The urethral closure function in continent women and the dysfunction causing SUI are not known in details. The currently accepted view is based on the concept of a sphincteric unit and a support system. Our incomplete knowledge relates to the complexity of the closure apparatus and to inadequate assessment methods which so far have not provided robust urodynamic diagnostic tools, severity measures, or parameters to assess outcome after intervention. Urethral Pressure Reflectometry (UPR) is a novel method that measures the urethral pressure and cross-sectional area (by use of sound waves) simultaneously. The technique involves insertion of only a small, light and flexible polyurethane bag in the urethra and therefore avoids the common artifacts encountered with conventional methods. The UPR parameters can be obtained at a specific site of the urethra, e.g. the high pressure zone, and during various circumstances, i.e. resting and squeezing. During the study period, we advanced the UPR technique to enable faster measurement (within 7 seconds by the continuous technique) which allowed assessment during increased intra-abdominal pressure induced by physical straining. We investigated the urethral closure function in continent and SUI women during resting and straining by the "fast" UPR technique. Thereby new promising urethral parameters were provided that allowed characterization of the closure function based on the permanent closure forces (primarily generated by the sphincteric unit, measured by the Po-rest) and the adjunctive closure forces (primarily generated by the support system, measured by the abdominal to urethral pressure impact ratio (APIR)). The new parameters enabled a more detailed description of the efficiency of the closure function and the extent and nature of a possible dysfunction in the individual woman. The urethral closure equation (UCE) and urethral opening pressure at an abdominal pressure of 50 cm H2O (Po-Abd 50), respectively, which combine the permanent and the adjunctive closure forces, could separate continent and SUI women and thus appear to be excellent diagnostic tests. Moreover, the parameters showed highly significant negative correlation with ICIQ-SF, pad test and the number of incontinence episodes per week and are therefore valid as urodynamic severity measures. UPR in SUI women before and after TVT demonstrated a more efficient urethral closure function after the operation. The Po-rest was unchanged suggesting that the sphincteric unit was virtually unaltered and hence the permanent closure forces unchanged. However, the resting opening elastance increased by 18% indicating that at the resting state the TVT somewhat improves the closure function by providing increased resistance against the dilation of the urethra, which probably explains the decreased maximum urine flow rate found after TVT in this and previous studies. The APIR increased in all patients after TVT suggesting that the support system was re-established and thus the adjunctive closure forces improved, regardless of the type of pre-operative dysfunction. The new UPR parameters may be used as outcome measures after treatment.
Unna sleeve for neurotic excoriations.
Paley, Kristina; Prevost, Noel; English, Joseph C
2010-03-01
Neurotic excoriations are self-induced skin lesions produced because of compulsive scratching or picking. We present the successful use of the venerable technique of an Unna boot used as an Unna sleeve for neurotic excoriations of the upper extremities.
New nut and sleeve improve flared connections
NASA Technical Reports Server (NTRS)
Garrard, J. S.
1965-01-01
Improved nut and sleeve of standard stainless steel flared tube connection allows forces on the mating surfaces to be uniformly applied. This can be applied to pressurized fluid systems such as refrigeration, air conditioning, and hydraulic systems.
Sleeve Push Technique: A Novel Method of Space Gaining.
Verma, Sanjeev; Bhupali, Nameksh Raj; Gupta, Deepak Kumar; Singh, Sombir; Singh, Satinder Pal
2018-01-01
Space gaining is frequently required in orthodontics. Multiple loops were initially used for space gaining and alignment. The most common used mechanics for space gaining is the use of nickel-titanium open coil springs. The disadvantage of nickel-titanium coil spring is that they cannot be used until the arches are well aligned to receive the stiffer stainless steel wires. Therefore, a new method of gaining space during initial alignment and leveling has been developed and named as sleeve push technique (SPT). The nickel-titanium wires, i.e. 0.012 inches and 0.014 inches along with archwire sleeve (protective tubing) can be used in a modified way to gain space along with alignment. This method helps in gaining space right from day 1 of treatment. The archwire sleeve and nickel-titanium wire in this new SPT act as a mutually synergistic combination and provide the orthodontist with a completely new technique for space opening.
Hosseini, Seyyed Yousef; Safarinejad, Mohammad Reza
2005-01-01
Our aim was to evaluate the results of early versus delayed internal urethrotomy for management of recurrent urethral strictures after posterior urethroplasty in children. Twenty boys with proven posterior urethral strictures were treated by perineal posterior urethroplasty. Of these, 12 required internal urethrotomy. Each radiograph demonstrated a patent but irregular urethra with a decrease in diameter at the point of repair (fair results). Patients were then divided into 2 groups: 6 underwent early (within 6 weeks from urethroplasty), and 6 underwent delayed (after 12 weeks from urethroplasty), internal urethrotomy with the cold knife as a complementary treatment. The groups were comparable in terms of patient age, etiology of the primary urethral stricture, number of recurrences, length and site of the actual stricture, and preoperative maximum flow rate. Mean follow-up was 5 years. Kaplan-Meier analyses showed that the stricture-free rate was 66.6% after early, and 33.3% after delayed, internal urethrotomy (P = .03). Early internal urethrotomy should be considered in boys with recurrent urethral stricture after urethroplasty.
Post-traumatic female urethral reconstruction.
Blaivas, Jerry G; Purohit, Rajveer S
2008-09-01
Post-traumatic urethral damage resulting in urethrovaginal fistulas or strictures, though rare, should be suspected in patients who have unexpected urinary incontinence or lower urinary tract symptoms after pelvic surgery, pelvic fracture, a long-term indwelling urethral catheter, or pelvic radiation. Careful physical examination and cystourethroscopy are critical to diagnose and assess the extent of the fistula. A concomitant vesicovaginal or ureterovaginal fistula should also be ruled out. The two main indications for reconstruction are sphincteric incontinence and urethral obstruction. Surgical correction intends to create a continent urethra that permits volitional, painless, and unobstructed passage of urine. An autologous pubovaginal sling, with or without a Martius flap at time of reconstruction, should be considered. The three approaches to urethral reconstruction are anterior bladder flaps, posterior bladder flaps, and vaginal wall flaps. We believe vaginal flaps are usually the best option. Options for vaginal repair of fistula include primary closure, peninsula flaps, bilateral labial pedicle flaps, and labial island flaps. Outcomes are optimized by using exacting surgical principles during repair and careful postoperative management by an experienced reconstructive surgeon.
Traumatic injuries to the urethra.
McAninch, J W
1981-04-01
Major urethral injuries from external trauma are complex problems of diagnosis and treatment. Complications resulting from injury, failed diagnosis, and inappropriate therapy include stricture, impotent, and incontinence. Opinions differ as to whether immediate suprapubic cystostomy followed by later reconstruction is preferable to immediate direct urethral realignment. A review of 30 patients with urethral injuries is presented, 27 male and three female, 29 from blunt trauma and one gunshot. Initial suprapubic cystostomy alone was used in 26 male patients, 21 with prostatomembranous disruption and five with straddle injury. Prostatomembranous reconstruction in 14 complete urethral transections resulted in one residual stricture, two impotent patients, and no incontinence. Partial prostatomembranous disruption and straddle injuries had insignificant residual stricture, none requiring dilation or reconstruction. The results of this management approach appear superior to those of immediate urethral realignment. Advantages of immediate suprapubic cystostomy are: 1) simplified early approach in management, and 2) successful elective reconstruction of major prostatomembranous injuries with low incidence of stricture, impotence, and incontinence.
PCR for diagnosis of male Trichomonas vaginalis infection with chronic prostatitis and urethritis.
Lee, Jong Jin; Moon, Hong Sang; Lee, Tchun Yong; Hwang, Hwan Sik; Ahn, Myoung-Hee; Ryu, Jae-Sook
2012-06-01
The aim of this study was to assess the usefulness of PCR for diagnosis of Trichomonas vaginalis infection among male patients with chronic recurrent prostatitis and urethritis. Between June 2001 and December 2003, a total of 33 patients visited the Department of Urology, Hanyang University Guri Hospital and were examined for T. vaginalis infection by PCR and culture in TYM medium. For the PCR, we used primers based on a repetitive sequence cloned from T. vaginalis (TV-E650). Voided bladder urine (VB1 and VB3) was sampled from 33 men with symptoms of lower urinary tract infection (urethral charge, residual urine sensation, and frequency). Culture failed to detect any T. vaginalis infection whereas PCR identified 7 cases of trichomoniasis (21.2%). Five of the 7 cases had been diagnosed with prostatitis and 2 with urethritis. PCR for the 5 prostatitis cases yielded a positive 330 bp band from bothVB1 and VB3, whereas positive results were only obtained from VB1 for the 2 urethritis patients. We showed that the PCR method could detect T. vaginalis when there was only 1 T. vaginalis cell per PCR mixture. Our results strongly support the usefulness of PCR on urine samples for detecting T. vaginalis in chronic prostatitis and urethritis patients.
Singh, Bhupendra P; Pathak, Hemant R; Andankar, Mukund G
2009-04-01
For management of long segment anterior urethral stricture, dorsal onlay urethroplasty is currently the most favored single-stage procedure. Conventional dorsal onlay urethroplasty requires circumferential mobilization of the urethra, which might cause ischemia of the urethra in addition to chordee. To determine the feasibility and short-term outcomes of applying a dorsolateral free graft to treat anterior urethral stricture by unilateral urethral mobilization through a perineal approach. A prospective study from September 2005 to March 2008 in a tertiary care teaching hospital. Seventeen patients with long or multiple strictures of the anterior urethra were treated by a dorsolateral free buccal mucosa graft. The pendulous urethra was accessed by penile eversion through the perineal wound. The urethra was not separated from the corporal bodies on one side and was only mobilized from the midline on the ventral aspect to beyond the midline on the dorsal aspect. The urethra was opened in the dorsal midline over the stricture. The buccal mucosa graft was secured on the ventral tunica of the corporal bodies. Mean and median. After a follow-up of 12-30 months, one recurrence developed and 1 patient needed an internal urethrotomy. A unilateral urethral mobilization approach for dorsolateral free graft urethroplasty is feasible for panurethral strictures of any length with good short-term success.
Wang, Yong-Quan; Zhang, Heng; Shen, Wen-Hao; Li, Long-Kun; Li, Wei-Bing; Xiong, En-Qing
2012-04-01
To investigate the outcomes of perineal urethrostomy plus secondary urethroplasty for ultralong urethral stricture and assess its influence on the patient's quality of life. We retrospectively analyzed 54 cases of ultralong urethral stricture treated by perineal urethrostomy from 2000 to 2010. The mean age of the patients was 40 years, and the average length of stricture was 6.5 cm. We evaluated the patients'quality of life by questionnaire investigation and the clinical outcomes based on IPSS, Qmax, the necessity of urethral dilation and satisfaction of the patients. The mean Qmax of the 54 patients was (14.0 +/- 4.7) ml/min. Of the 34 cases that underwent secondary urethroplasty, 22 (64.7%) achieved a mean Qmax of (12.0 +/- 3.5) ml/min, 8 (23.5%) needed regular urethral dilatation and 4 (11.8%) received internal urethrotomy because of restenosis. IPSS scores were 5.4 +/- 2.1 and 8.5 +/- 5.8 after perineal urethrostomy and secondary urethroplasty, respectively. Fifty of the total number of patients (92.6%) were satisfied with the results of perineal urethrostomy, and 22 of the 34 (64.7%) with the results of secondary urethroplasty. Perineal urethrostomy plus secondary urethroplasty is safe and effective for ultralong urethral stricture, and affects very little the patient's quality of life.
Traumatic lesions of the posterior urethra.
Velarde-Ramos, L; Gómez-Illanes, R; Campos-Juanatey, F; Portillo-Martín, J A
2016-11-01
The posterior urethral lesions are associated with pelvis fractures in 5-10% of cases. The posterior urethra is attached to the pelvis bone by puboprostatic ligaments and the perineal membrane, which explains why disruption of the pelvic ring can injure the urethra at this level. To identify suspected cases of posterior urethral trauma and to perform the diagnosis and its immediate or deferred management. Search in PubMed of articles related to traumatic posterior urethral lesions, written in English or Spanish. We reviewed the relevant publications including literature reviews and chapters from books related to the topic. With patients with pelvis fractures, we must always rule out posterior urethral lesions. The diagnostic examination of choice is retrograde urethrography, which, along with the severity of the condition, will determine the management in the acute phase and whether the treatment will be performed immediately or deferred. Early diagnosis and proper acute management decrease the associated complications, such as strictures, urinary incontinence and erectile dysfunction. Despite the classical association between posterior urethral lesions and pelvic fractures, the management of those lesions (whether immediate or deferred) remains controversial. Thanks to the growing interest in urethral disease, there are an increasing number of studies that help us achieve better management of these lesions. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Factors affecting urethrocystographic parameters in urinary continent women.
Yang, J M
1996-06-01
To evaluate the urethrocystographic changes in different conditions, 154 women were evaluated by using introital sonography. Patients were divided into three groups: group 1 (n = 103) normal, including 10 postmenopausal women; group 2 (n = 46) pregnant, including 16 women in the first trimester, 15 in the second trimester, and 15 in the third trimester; group 3 (n = 15) severe genitourinary prolapse. None of the 154 women had a history of urinary incontinence. The following parameters were measured at rest: urethral thickness, uretheral length, urethral inclination, and posterior urethrovesical angle. On maximum straining, urethral inclination, posterior urethrovesical angle, and rotational angle were measured. In general, age, parity, and menopause did not affect the urethrocystographic parameters in Group 1 patients. Postmenopausal women had a significant decrease in the urethral thickness compared with the premenopausal women (p = 0.026). Patients in Groups 2 and 3 had a significantly lower urethral position than those in group 1. However, hypermobility of the urethra was found only in Group 3. Different menstrual ages did not affect the urethral position but could affect the posterior urethrovesical angle at rest in the first trimester. Introital sonography, without the risk of radiation exposure, enables the observation of static and dynamic changes in the lower urinary tract, both repeatedly and reproducibly.
Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun
2011-01-01
When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5-10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire.
Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun
2011-01-01
When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5–10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire. PMID:22110492
Zhou, Yi; Li, Gong-hui; Yan, Jia-jun; Shen, Cong; Tang, Gui-hang; Xu, Gang
2016-01-01
To investigate the clinical application of the ureteral dilation catheter combined with the balloon catheter under the ureteroscope in the treatment of urethral stricture in men. Under the ureteroscope, 45 male patients with urethral stricture received placement of a zebra guide wire through the strictured urethra into the bladder and then a ureteral dilation catheter along the guide wire, followed by dilation of the urethra from F8 initially to F14 and F16. Again, the ureteroscope was used to determine the length of the strictured urethra, its distance to the external urethral orifice, and whether it was normally located. An F24 balloon catheter and then a metal urethral calibrator was used for the dilation of the strictured urethra. After removal of the F18-F22 urethral catheter at 8 weeks, the urinary flow rate was measured immediately and again at 3 months. All the operations were successfully performed without serious complications. The maximum urinary flow rate was (13.3-29.9) ml/s (mean [17.7 ± 3.2] ml/s) at the removal of the catheter and (15.2-30.8) ml/s (mean [19.8 ± 3.9] ml/s) at 3 months after it. Smooth urination was found in all the patients during the 6-24 months follow-up. The application of the ureteral dilation catheter combined with, the balloon catheter under the ureteroscope is a good option for the treatment of male urethral stricture for its advantages of uncomplicatedness, safety, effectiveness, few complications, less pain, high success rate, and repeatable operation.
Zhou, Tie; Chen, Guanghua; Zhang, Wei; Peng, Yonghan; Xiao, Liang; Xu, Chuangliang; Sun, Yinghao
2013-01-01
The prevalence of lower urinary tract symptoms (LUTS) is about 20% in men aged 40 or above. Other than benign prostatic hyperplasia (BPH), urethral diverticulum or calculus is not uncommon for LUTS in men. Surgical treatment is often recommended for urethral diverticulum or calculus, but treatment for an impacted urethral calculus complicated by a stone-containing diverticulum is challenging. An 82-year-old man had the persistence of LUTS despite having undergone transurethral resection of prostate for BPH. Regardless of treatment with broad spectrum antibiotics and an α-blocker, LUTS and post-void residual urine volume (100 mL) did not improve although repeated urinalysis showed reduction of WBCs from 100 to 10 per high power field. Further radiology revealed multiple urethral calculi and the stone configuration suggested the existence of a diverticulum. He was successfully treated without resecting the urethral diverticulum; and a new generation of ultrasound lithotripsy (EMS, Nyon, Switzerland) through a 22F offset rigid Storz nephroscope (Karl Storz, Tuttingen, Germany) was used to fragment the stones. The operative time was 30 minutes and the stones were cleanly removed. The patient was discharged after 48 hours with no immediate complications and free of LUTS during a 2 years follow-up. When the diverticulum is the result of a dilatation behind a calculus, removal of the calculus is all that is necessary. Compared with open surgery, ultrasound lithotripsy is less invasive with little harm to urethral mucosa; and more efficient as it absorbs stone fragments while crushing stones.
Stafford, Ryan E; Mazzone, Stuart; Ashton-Miller, James A; Constantinou, Christos; Hodges, Paul W
2014-04-15
Coughing provokes stress urinary incontinence, and voluntary coughs are employed clinically to assess pelvic floor dysfunction. Understanding urethral dynamics during coughing in men is limited, and it is unclear whether voluntary coughs are an appropriate surrogate for spontaneous coughs. We aimed to investigate the dynamics of urethral motion in continent men during voluntary and evoked coughs. Thirteen men (28-42 years) with no history of urological disorders volunteered to participate. Transperineal ultrasound (US) images were recorded and synchronized with measures of intraabdominal pressure (IAP), airflow, and abdominal/chest wall electromyography during voluntary coughs and coughs evoked by inhalation of nebulized capsaicin. Temporal and spatial aspects of urethral movement induced by contraction of the striated urethral sphincter (SUS), levator ani (LA), and bulbocavernosus (BC) muscles and mechanical aspects of cough generation were investigated. Results showed coughing involved complex urethral dynamics. Urethral motion implied SUS and BC shortening and LA lengthening during preparatory and expulsion phases. Evoked coughs resulted in greater IAP, greater bladder base descent (LA lengthening), and greater midurethral displacement (SUS shortening). The preparatory inspiration cough phase was shorter during evoked coughs, as was the latency between onset of midurethral displacement and expulsion. Maximum midurethral displacement coincided with maximal bladder base descent during voluntary cough, but followed it during evoked cough. The data revealed complex interaction between muscles involved in continence in men. Spatial and temporal differences in urethral dynamics and cough mechanics between cough types suggest that voluntary coughing may not adequately assess capacity of the continence mechanism.
Kawano, Paulo Roberto; Fugita, Oscar Eduardo Hidetoshi; Yamamoto, Hamilto Akihissa; Quitzan, Juliany Gomes; Padovani, Carlos; Amaro, João Luiz
2012-05-01
Several urethral conditions may require tissue substitution. One collagen-base biomaterial that recently emerged as an option is small intestinal submucosa (SIS). The aim of this study was to compare the results of SIS and buccal mucosa for urethral substitution in rabbits. Thirty-six North Folk male rabbits were randomized into three groups. In all animals, a 10 × 5 mm urethral segment was excised, and the urethral defect was repaired using a one-layer SIS patch (group I [GI]); four-layer SIS (group II [GII]); or buccal mucosa (group III [GIII]). Urethrography was performed preoperatively and after 12 weeks. After sacrifice, graft retraction was objectively measured using Scion Image(®) computer analysis and by calculation of ellipse area. The grade of fibrosis, inflammatory reaction, vascular/epithelial regeneration, and collagen III/I ratio were analyzed by hematoxylin/eosin and Picrosirius red staining. Urethrography confirmed a wide urethral caliber without any signs of strictures after surgery. Urethral fistulae was diagnosed in 8.3% of cases (1 animal each group). Average graft shrinkage was 55.2% in GI; 44.2% in GII; and 57.2% in GIII (p<0.05). The intensity of chronic inflammation, fibrosis, epithelium regeneration, and neovascularization was similar in all groups (p>0.05). Collagen III/I ratio was higher in GII (GI: 119.6; GII: 257.2 and GIII: 115.0); p<0.01. The four-layer SIS is more advantageous than the one-layer SIS and buccal mucosa for urethral substitution in rabbits.
Redo-urethroplasty in pelvic fracture urethral distraction defect: an audit.
Bhagat, Suresh K; Gopalakrishnan, Ganesh; Kumar, Santosh; Devasia, Antony; Kekre, Nitin S
2011-02-01
To predict the outcome of redo-urethroplasty after failed single or multiple open urethral procedures for pelvic fracture urethral distraction defects. From January 1997 to December 2006, 43 patients underwent redo-urethroplasty for pelvic fracture urethral distraction defect. Forty-one were referred from other centers. All had undergone open surgery along with an endoscopic procedure (one or more procedures in each patient) which included endoscopic internal urethrotomy, urethral stenting or urethral dilations. There were 43 men with mean age of 29 (range 11-52). Eleven had associated injuries: intraperitoneal bladder rupture (3), bladder neck (2), rectum (3), anal sphincter (2), combined bladder, rectum and anal sphincter (1). Trocar suprapubic cystostomy was performed in 22, rail-road procedures in 10 and open suprapubic cystostomy in 11 along with the management of associated injuries as immediate treatment. Of 43 patients, 28 had progressive perineal, and 12 had transpubic repair. Three patients had total bulbar necrosis, and they underwent prepuceal tube reconstruction (1) and staged substitution with BMG and standard scrotal inlay (2). Analysis of various factors like number of attempts at previous surgery and stricture length did not affect the outcome. A successful result was achieved in 36 (83.72%), improved and stable in five and failure in two. The overall result of redo-urethroplasty for pelvic fracture urethral distraction defect continues to be gratifying. Failures happen usually within the first 3 months. Substitution urethroplasty can be reserved for those who have long distraction defect. Long-term follow-up is essential using stringent criteria to measure success.
Shittu, O B; Sotunmbi, P T
2015-06-01
Urethroplasty is often required for long urethral strictures or urethral strictures that have recurred after repeated urethral dilatations or urethrotomy. The transvers penile skin pedicled flap is very versatile for the reconstruction of long urethral stricture. However the meticulous sharp dissection required to develop it takes a long time to do and may be associated with button hole injuries to the vascular pedicle and the penile skin. We describe a simplified technique of raising the flap which does not require sharp dissection and is very quick to accomplish. Technique involves using a circumcising distal penile shaft skin incision to de-glove the penis by blunt dissection. The skin substitute, adequate to give appropriate urethra calibre is similarly dissected bluntly along with its vascular pedicle from the proximal penile skin. The techniques used to facilitate successful blunt dissection are described. In 9 adults with long, multiple urethral strictures, the average time to develop the flap was 15 minutes and complication have been limited to temporary urethro-cutaneous fistula at the ventral part of the circular skin closure. These fistulae closed on conservative treatment. No patient suffered button-hole injuries to either the vascular pedicle or the penile skin. This modification to the standard sharp dissection is very quick to accomplish. It also avoids the creation of button-hole injuries to either the vascular pedicle or the penile skin. It should make the use of this versatile flap more attractive in the reconstruction of long urethral strictures in those who may wish to use this option for reconstruction of long urethral strictures.
Guo, Hailin; Sa, Yinglong; Fu, Qiang; Jin, Chongrui; Wang, Lin
2017-07-01
Pelvic fracture urethral defects associated with urethrorectal fistulas are rare and difficult to repair. The aim of this study was to evaluate the efficacy of transperineal urethroplasty with gracilis muscle interposition for the repair of pelvic fracture urethral defects associated with urethrorectal fistulas. We identified 32 patients who underwent transperineal urethroplasty with gracilis muscle interposition to repair pelvic fracture urethral defects associated with urethrorectal fistulas. Patient demographics as well as preoperative, operative and postoperative data were obtained. Mean followup was 33 months (range 6 to 64). The overall success rate was 91% (29 of 32 cases). One-stage repair was successful in 17 of 18 patients (94%) using perineal anastomosis with separation of the corporeal body and in 12 of 14 (86%) using perineal anastomosis with inferior pubectomy and separation of the corporeal body. All 22 patients (100%) without a previous history of repair were successfully treated. However, only 7 of 10 patients (70%) with a previous history of failed urethroplasty and urethrorectal fistula repair were cured. Recurrent urethral strictures developed in 2 cases. One patient was treated successfully with optical internal urethrotomy and the other was treated successfully with tubed perineoscrotal flap urethroplasty. Recurrent urethrorectal fistulas associated with urethral strictures developed in an additional patient. Transperineal urethroplasty with gracilis muscle interposition is a safe and effective surgical procedure for most pelvic fracture urethral defects associated with urethrorectal fistulas. Several other factors may affect its postoperative efficiency. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Dorsal inlay buccal mucosal graft (Asopa) urethroplasty for anterior urethral stricture
Marshall, Stephen D.; Raup, Valary T.
2015-01-01
Asopa described the inlay of a graft into Snodgrass’s longitudinal urethral plate incision using a ventral sagittal urethrotomy approach in 2001. He claimed that this technique was easier to perform and led to less tissue ischemia due to no need for mobilization of the urethra. This approach has subsequently been popularized among reconstructive urologists as the dorsal inlay urethroplasty or Asopa technique. Depending on the location of the stricture, either a subcoronal circumferential incision is made for penile strictures, or a midline perineal incision is made for bulbar strictures. Other approaches for penile urethral strictures include the non-circumferential penile incisional approach and a penoscrotal approach. We generally prefer the circumferential degloving approach for penile urethral strictures. The penis is de-gloved and the urethra is split ventrally to exposure the stricture. It is then deepened to include the full thickness of the dorsal urethra. The dorsal surface is made raw and grafts are fixed on the urethral surface. Quilting sutures are placed to further anchor the graft. A Foley catheter is placed and the urethra is retubularized in two layers with special attention to the staggering of suture lines. The skin incision is then closed in layers. We have found that it is best to perform an Asopa urethroplasty when the urethral plate is ≥1 cm in width. The key to when to use the dorsal inlay technique all depends on the width of the urethral plate once the urethrotomy is performed, stricture etiology, and stricture location (penile vs. bulb). PMID:26816804
Olajide, Abimbola Olaniyi; Olajide, Folakemi Olajumoke; Kolawole, Oladapo Adedayo; Oseni, Ismaila; Ajayi, Adewale Idowu
2013-11-01
Management of urethral stricture has evolved over the years with better understanding of the pathology, advancement in imaging, and introduction of several techniques of urethral reconstruction. In sub-Saharan Africa, advancement in management of urethral stricture may not be comparable with what obtained in most developed nations because of problems like late presentation and persistence of rare complications still reported in recent literature from the region. We set to evaluate the challenges faced by urologists involved in the management of urethral strictures in Osogbo, a poor resource community in south western Nigeria. A retrospective study was performed in the urology unit of Ladoke Akintola University of Technology Teaching Hospital, Osogbo, Nigeria between July 2007 and July 2012. Information was retrieved from patients' clinical notes and analyzed using statistical package for social sciences (SPSS) version 16.0. Eighty-four patients were treated during the period of study, their ages ranged between 19 and 89 years with the mean age of 52.3 years. The mean duration of symptoms before presentation was 3 years and 1 month. Inflammation resulting from sexually transmitted infection was the commonest etiology and more than 50% of the patients presented with complications. Sixteen patients (19.1%) received no treatment due to lack of fund. More than 90% were dependent, unemployed or underemployed. Single stage reconstruction by urethral substitution was the commonest form of repair with the restenosis rate of 4.4%. Prevalent socio-cultural and economic situation in south western Nigeria have added some peculiar challenges to the management of urethral stricture in the region.
Delayed repair of post-traumatic posterior urethral distraction injuries: long-term results.
Tunc, H M; Tefekli, A H; Kaplancan, T; Esen, T
2000-06-01
There is still controversy regarding the treatment of post-traumatic posterior urethral distraction injuries. Initial suprapubic cystostomy and delayed perineal urethral reconstruction has been considered the reference standard. In this report, we review our experience with delayed perineal urethral reconstruction, with a focus on the long-term outcome and complications. A total of 77 men with posterior urethral distraction injury due to pelvic trauma underwent reconstruction with delayed perineal approach. In all cases, the area of fibrosis was aggressively excised, the corpus spongiosum was mobilized, and a tension-free, spatulated end-to-end anastomosis was achieved by splitting the corporeal bodies in 66.2% and by an additional perineally performed inferior pubectomy in 49.3% of the patients. The median time from injury to surgical repair was 12 months. The preoperative evaluation consisted of combined antegrade and retrograde cystourethrograms and cystourethrography. A detailed sexual history was obtained in 58 patients (75.3%). After a mean follow-up of 47 months (range 15 months to 14 years), the urethral continuity was adequate in 94. 8%; however, 2 patients required a perineal surgical revision (total of 79 operations). Postoperative incontinence was observed in 7 (9. 1%) of 77 patients. Postoperative erectile dysfunction was noted in 16.2% of patients who were known to be potent by history before surgery. Our results support the belief that delayed perineal reconstruction with extensive excision of fibrosis and a tension-free, spatulated end-to-end anastomosis is a successful treatment alternative for posterior urethral distraction defects, with acceptable morbidity.
Beaudreuil, Johann; Bendaya, Samy; Faucher, Marc; Coudeyre, Emmanuel; Ribinik, Patricia; Revel, Michel; Rannou, François
2009-12-01
To develop clinical practice guidelines concerning the use of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis. The French Physical Medicine and Rehabilitation Society (SOFMER) methodology, associating a systematic literature review, collection of everyday clinical practice, and external review by multidisciplinary expert panel, was used. Few high-level studies of bracing for knee osteoarthritis were found. No evidence exists for the effectiveness of rest orthosis. Evidence for knee sleeves suggests that they decrease pain in knee osteoarthritis, and their use is associated with subjective improvement. These actions do not appear to depend on a local thermal effect. The effectiveness of knee sleeves for disability is not demonstrated for knee osteoarthritis. Short- and mid-term follow-up indicates that valgus knee bracing decreases pain and disability in medial knee osteoarthritis, appears to be more effective than knee sleeves, and improves quality of life, knee proprioception, quadriceps strength, and gait symmetry, and decreases compressive loads in the medial femoro-tibial compartment. However, results of response to valgus knee bracing remain inconsistent; discomfort and side effects can result. Thrombophlebitis of the lower limbs has been reported with the braces. Braces, whatever kind, are infrequently prescribed in clinical practice for osteoarthritis of the lower limbs. Modest evidence exists for the effectiveness of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis, with only low level recommendations for its use. Braces are prescribed infrequently in French clinical practice for osteoarthritis of the knee. Randomized clinical trials concerning bracing in knee osteoarthritis are still necessary.
García-Díaz, Juan José; Ferrer-Márquez, Manuel; Moreno-Serrano, Almudena; Barreto-Rios, Rogelio; Alarcón-Rodríguez, Raquel; Ferrer-Ayza, Manuel
2016-01-01
Laparoscopic sleeve gastrectomy is a surgical procedure for the treatment of morbid obesity. However, there are still controversies regarding its efficiency in terms of weight reduction and incidence of complications. In this prospective study, the experience is presented of a referral centre for the treatment of morbid obesity with laparoscopic sleeve gastrectomy. A prospective study on 73 patients subjected to laparoscopic sleeve gastrectomy from February 2009 to September 2013. Patients were followed-up for a period of 12 months, evaluating the development of complications, reduction of gastric volume, and the weight loss associated with the surgery, as well as their impact on the improvement of comorbidities present at beginning of the study. There was a statistically a significantly reduction between the preoperative body mass index (BMI) and the BMI at 12 months after laparoscopic sleeve gastrectomy (p < 0.001), despite there being an increase in the gastric volume during follow-up, measured at one month and 12 months after surgery (p < 0.001). Five patients (6.85%) had complications, with none of them serious and with no deaths in the whole series. Laparoscopic sleeve gastrectomy is a safe and effective technique for the treatment of morbid obesity. Its use is associated with a significant reduction in the presence of comorbidities associated with obesity. Multicentre studies with a longer period of monitoring are required to confirm the efficacy and safety of this surgical technique. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.
Visibility of the urethral meatus and risk of urinary tract infections in uncircumcised boys
Dubrovsky, Alexander Sasha; Foster, Bethany J.; Jednak, Roman; Mok, Elise; McGillivray, David
2012-01-01
Background: Uncircumcised boys are at higher risk for urinary tract infections than circumcised boys. Whether this risk varies with the visibility of the urethral meatus is not known. Our aim was to determine whether there is a hierarchy of risk among uncircumcised boys whose urethral meatuses are visible to differing degrees. Methods: We conducted a prospective cross-sectional study in one pediatric emergency department. We screened 440 circumcised and uncircumcised boys. Of these, 393 boys who were not toilet trained and for whom the treating physician had requested a catheter urine culture were included in our analysis. At the time of catheter insertion, a nurse characterized the visibility of the urethral meatus (phimosis) using a 3-point scale (completely visible, partially visible or nonvisible). Our primary outcome was urinary tract infection, and our primary exposure variable was the degree of phimosis: completely visible versus partially or nonvisible urethral meatus. Results: Cultures grew from urine samples from 30.0% of uncircumcised boys with a completely visible meatus, and from 23.8% of those with a partially or nonvisible meatus (p = 0.4). The unadjusted odds ratio (OR) for culture growth was 0.73 (95% confidence interval [CI] 0.35–1.52), and the adjusted OR was 0.41 (95% CI 0.17–0.95). Of the boys who were circumcised, 4.8% had urinary tract infections, which was significantly lower than the rate among uncircumcised boys with a completely visible urethral meatus (unadjusted OR 0.12 [95% CI 0.04–0.39], adjusted OR 0.07 [95% CI 0.02–0.26]). Interpretation: We did not see variation in the risk of urinary tract infection with the visibility of the urethral meatus among uncircumcised boys. Compared with circumcised boys, we saw a higher risk of urinary tract infection in uncircumcised boys, irrespective of urethral visibility. PMID:22777988
The effect of platelet rich fibrin on growth factor levels in urethral repair.
Soyer, Tutku; Ayva, Şebnem; Boybeyi, Özlem; Aslan, Mustafa Kemal; Çakmak, Murat
2013-12-01
Platelet rich fibrin (PRF) is an autologous source of growth factors and promotes wound healing. An experimental study was performed to evaluate the effect of PRF on growth factor levels in urethral repair. Eighteen Wistar albino rats were included in the study. Rats were allocated in three groups (n:6): control (CG), sham (SG), and PRF (PRFG). In SG, a 5 mm vertical incision was performed in the penile urethra and repaired with 10/0 Vicryl® under a microscope. In PRFG, during the urethral repair as described in SG, 1 cc of blood was sampled from each rat and centrifuged for 10 minutes at 2400 rpm. PRF obtained from the centrifugation was placed on the repair site during closure. Penile urethras were sampled 24 hours after PRF application in PRFG and after urethral repair in SG. Transforming growth factor beta receptor (TGF-β-R-CD105), vascular endothelial growth factor (VEGF) and its receptor (VEGF-R), as well as endothelial growth factor receptor (EGFR), were evaluated in subepithelia of the penile skin and urethra. Groups were compared for growth factor levels and growth factor receptor expression with the Kruskal Wallis test. TGF-β-R levels were significantly decreased in SG when compared to CG (p<0.05). In PRFG, TGF-β-R was increased in both subepithelia of penile skin and urethra with respect to SG (p<0.05). When VEGF levels and its receptor expression were compared between SG and PRFG, VEGF levels were found to be increased in penile skin subepithelium, whereas VEGF-R expressions were decreased in urethral subepithelia in PRFG (p<0.05). There was no difference between groups for EGFR levels (p>0.05). Use of PRF after urethral repair increases TGF-β-R and VEGF expressions in urethral tissue. PRF can be considered as an alternative measure to improve the success of urethral repair. © 2013.
Garofalo, Marco; Bianchi, Lorenzo; Gentile, Giorgio; Borghesi, Marco; Vagnoni, Valerio; Dababneh, Hussam; Schiavina, Riccardo; Franceschelli, Alessandro; Romagnoli, Daniele; Colombo, Fulvio; Corcioni, Beniamino; Golfieri, Rita; Brunocilla, Eugenio
2015-09-30
To present the management of a patient with partial disruption of both cavernosal bodies and complete urethral rupture and to propose a non-systematic review of literature about complete urethral rupture. MATERIAL AND METHOD - CASE REPORT: A 46 years old man presented to our emergency department after a blunt injury of the penis during sexual intercourse. On physical examination there was subcutaneous hematoma extending over the proximal penile shaft with a dorsal-left sided deviation of the penis and urethral bleeding. Ultrasound investigation showed an hematoma in the ventral shaft of the penis with a discontinuity of the tunica albuginea of the right cavernosal corporum. The patient underwent immediate emergency surgery consisted on evacuation of the hematoma, reparation the partial defect of both two cavernosal bodies and end to end suture of the urethra that resulted completely disrupted. The urethral catheter was removed at the 12-th postoperative day without voiding symptoms after a retrograde urethrography. 6 months postoperatively the patients was evaluated with uroflowmetry demonstrating a max flow rate of 22 ml/s and optimal functional outcomes evaluated with validated questionnaires. 8 months after surgery the patients was evaluated by dynamic magnetic resonance (MRI) of the penis showing only a little curvature on the left side of the penile shaft. Penile fracture is an extremely uncommon urologic injury with approximately 1331 reported cases in the literature till the years 2001. To best of our knowledge from 2001 up today, 1839 more cases have been reported, only in 159 of them anterior urethral rupture was associated and in only 22 cases a complete urethral rupture was described. In our opinion, in order to prevent long term complications, in case of clinical suspicion of penile fracture, especially if it is associated to urethral disruption, emergency surgery should be the first choice of treatment.
Evaluation of syndromic patient management algorithm for urethral discharge.
Djajakusumah, T; Sudigdoadi, S; Keersmaekers, K; Meheus, A
1998-06-01
To determine feasibility, validity, and cost effectiveness of the syndromic approach to male patients with urethral discharge in Bandung, Indonesia. The WHO algorithm on urethral discharge with no microscopy available was evaluated. Patients presented with a complaint of urethral discharge and if discharge was confirmed the algorithm was applied. Treatment covered gonococcal and chlamydial infection (ciprofloxacin 500 mg single oral dose plus doxycycline 100 mg, twice daily orally for 7 days). The gold standard for validation was gonococcal culture and chlamydia antigen detection. 140 male patients with a complaint of urethral discharge were enrolled; 119 had confirmed discharge and entered the decision tree: 107 were followed and 104 (97%) were clinically cured. Of the three patients with persistent discharge, one had a purulent urethral discharge, diagnosed as gonococcal urethritis and he was probably reinfected; two patients had a serous discharge and microbiological tests were negative. Overall, 106 out of 107 patients (99%) were microbiologically cured. Sensitivity of the algorithm is 100% and its positive predictive value (PPV) is 75% or 97% if validated against gold standard microbiological tests or Gram stain, respectively. Cost per patient is rupiah (Rp)5.894 ($US2.56) for the algorithm compared with Rp43.024 ($18.70) for full microbiological diagnosis. The cost estimate for an algorithm of urethral discharge with microscopy available is Rp6.432 ($2.80) The "symptom and sign" algorithm is fully adapted to the prevailing situation in primary healthcare settings, is acceptable to healthcare workers and patients (who are effectively treated at their first visit), is highly cost effective, is 100% sensitive (no false negatives, which is not the case with microbiological diagnosis), and has a high PPV, between 75% and 97%. It is an excellent patient management tool and a sound basis for partner notification so that it should have a major impact on STD/HIV control and prevention in both men and women.
Mehmood, Shahbaz; Alsulaiman, Omer Abdulaziz; Al Taweel, Waleed Mohammad
2018-01-01
Purpose: We present our success rate and complications of delayed anastomotic urethroplasty (DAU) in patients with post-traumatic posterior urethral injury. Materials and Methods: This was a retrospective study of patients aged ≥17 years that underwent DAU for post-traumatic posterior urethral injury during 2010–2014. Stricture length was measured by ascending and descending urethrogram. Success of procedure was considered when the patient was free of stricture-ralated obstruction and needed no further intervention. Primary group includes patients who underwent first time delayed urethroplasty while secondary group included patients who had some sort of urethral manipulation in local hospital. Results were analyzed using unpaired t-test, Chi-square test, binary logistic regression, Kaplan–Meier curves, and log-rank test. Results: Of the 80 male patients, 73 (91.25%) patients underwent primary DAU while 7 (8.75%) patients had secondary DAU. Median age, stricture length, and follow-up were 27.0 ± 12.7, 1.6 ± 0.9, and 3.2 ± 0.9, respectively. Overall, success rate was 83.75% while success rate in primary group was 89.04% and secondary group was only 28.57% (P = 0.0059). Regarding ancillary maneuvers, urethral mobilization alone was done in 29 (36.25%) patients with success rate (72.41%), corporeal body separation in 36 (45%) patients with success rate (91.66%), inferior wedge pubectomy in 13 (16.25%) with success rate (84.61%), supracrural rerouting in 1 (1.25%) with success rate (100%), and abdominoperineal approach in 1 (1.25%) with success rate of 100% (P = 0.193). Patients who had prior urethral manipulation affect the outcome of definitive anastomotic urethroplasty. Conclusion: DAU has durable success rate with less morbidity. Ancillary elaborated maneuvers are frequently needed in patients with complex and elongated post-traumatic posterior urethral defect with successful outcome. PMID:29719330
Freitas, Gabrielle C.; Monteiro Carvalho Mori da Cunha, Marina G.; Gomes, Kleber; Monteiro Carvalho Mori da Cunha, João P.; Togni, Monique; Pippi, Ney L.; Carregaro, Adriano B.
2012-01-01
This study compared acid-base and biochemical changes and quality of recovery in male cats with experimentally induced urethral obstruction and anesthetized with either propofol or a combination of ketamine and diazepam for urethral catheterization. Ten male cats with urethral obstruction were enrolled for urethral catheterization and anesthetized with either ketamine-diazepam (KD) or propofol (P). Lactated Ringer’s solution was administered by intravenous (IV) beginning 15 min before and continuing for 48 h after relief of urethral obstruction. Quality of recovery and time to standing were evaluated. The urethral catheter was maintained to measure urinary output. Hematocrit (Hct), total plasma protein (TPP), albumin, total protein (TP), blood urea nitrogen (BUN), creatinine, pH, bicarbonate (HCO3−), chloride, base excess, anion gap, sodium, potassium, and partial pressure of carbon dioxide in mixed venous blood (pvCO2) were measured before urethral obstruction, at start of fluid therapy (0 h), and at subsequent intervals. The quality of recovery and time to standing were respectively 4 and 75 min in the KD group and 5 and 16 min in the P group. The blood urea nitrogen values were increased at 0, 2, and 8 h in both groups. Serum creatinine increased at 0 and 2 h in cats administered KD and at 0, 2, and 8 h in cats receiving P, although the values were above the reference range in both groups until 8 h. Acidosis occurred for up to 2 h in both groups. Acid-base and biochemical stabilization were similar in cats anesthetized with propofol or with ketamine-diazepam. Cats that received propofol recovered much faster, but the ketamine-diazepam combination was shown to be more advantageous when treating uncooperative cats as it can be administered by intramuscular (IM) injection. PMID:23277699
Greenwell, T J; Castle, C; Andrich, D E; MacDonald, J T; Nicol, D L; Mundy, A R
2004-07-01
We developed an algorithm for the management of urethral stricture based on cost-effectiveness. United Kingdom medical and hospital costs associated with the current management of urethral stricture were calculated using private medical insurance schedules of reimbursement and clean intermittent self-catheterization supply costs. These costs were applied to 126 new patients treated endoscopically for urethral stricture in a general urological setting between January 1, 1991 and December 31, 1999. Treatment failure was defined as recurrent symptomatic stricture requiring further operative intervention following initial intervention. Mean followup available was 25 months (range 1 to 132). The costs were urethrotomy/urethral dilation 2,250.00 pounds sterling (3,375.00 dollars, ratio 1.00), simple 1-stage urethroplasty 5,015.00 pounds sterling (7,522.50 dollars, ratio 2.23), complex 1-stage urethroplasty 5,335.00 pounds sterling (8,002.50 dollars, ratio 2.37) and 2-stage urethroplasty 10,370 pounds sterling (15,555.00 dollars, ratio 4.61). Of the 126 patients assessed 60 (47.6%) required more than 1 endoscopic retreatments (mean 3.13 each), 50 performed biweekly clean intermittent self-catheterization and 7 underwent urethroplasty during followup. The total cost per patient for all 126 patients for stricture treatment during followup was 6,113 pounds sterling (9,170 dollars). This cost was calculated by multiplying procedure cost by the number of procedures performed. A strategy of urethrotomy or urethral dilation as first line treatment, followed by urethroplasty for recurrence yielded a total cost per patient of 5,866 pounds sterling (8,799 dollars). A strategy of initial urethrotomy or urethral dilation followed by urethroplasty in patients with recurrent stricture proves to be the most cost-effective strategy. This financially based strategy concurs with evidence based best practice for urethral stricture management.
Iselin, C E; Webster, G D
1999-08-01
As a result of pelvic fracture urethral distraction defects, urinary continence relies predominantly on intact bladder neck function. Hence, when cystoscopy and/or cystography reveals an open bladder neck before urethroplasty, the probability of postoperative urinary incontinence may be significant. Unresolved issues are the necessity, the timing and the type of bladder neck repair. We report the outcome of various therapeutic options in patients with pelvic fracture urethral distraction defects and open bladder neck. We also attempt to identify prognostic factors of incontinence before urethroplasty. We retrospectively reviewed the records of 15 patients with a mean age of 30 years in whom an open bladder neck was identified before posterior urethroplasty between January 1981 and October 1997. Of the 15 patients 6 were continent and 8 were incontinent postoperatively. One patient underwent artificial urethral sphincter implantation simultaneously with pelvic fracture urethral distraction defect repair and was dry postoperatively without sphincter activation. Average bladder neck and prostatic urethral opening on the cystourethrogram before urethroplasty was significantly longer in incontinent (1.68 cm.) than in continent (0.9 cm.) patients. Of the 8 patients who were incontinent 6 underwent bladder neck reconstruction, 1 artificial urinary sphincter and 1 periurethral collagen implant. Five patients with bladder neck reconstruction are totally continent and 1 requires 1 pad daily. The patient who underwent collagen implant requires 2 pads daily and the patient who received an artificial urethral sphincter has minor urge leakage. Open bladder neck before urethroplasty may herald postoperative incontinence which may be predicted by radiographic and cystoscopic features. Evaluation of the risk of postoperative incontinence may be valuable, and eventually guide the necessity and timing of anti-incontinence surgery, although our preference remains to manage the pelvic fracture urethral distraction defects and bladder neck problem sequentially. Bladder neck reconstruction provides good postoperative continence rates and is our technique of choice.
Dynamics of the sensory response to urethral flow over multiple time scales in rat
Danziger, Zachary C; Grill, Warren M
2015-01-01
The pudendal nerve carries sensory information from the urethra that controls spinal reflexes necessary to maintain continence and achieve efficient micturition. Despite the key role urethral sensory feedback plays in regulation of the lower urinary tract, there is little information about the characteristics of urethral sensory responses to physiological stimuli, and the quantitative relationship between physiological stimuli and the evoked sensory activation is unknown. Such a relation is critical to understanding the neural control of the lower urinary tract and how dysfunction arises in disease states. We systematically quantified pudendal afferent responses to fluid flow in the urethra in vivo in the rat. We characterized the sensory response across a range of stimuli, and describe a previously unreported long-term neural accommodation phenomenon. We developed and validated a compact mechanistic mathematical model capable of reproducing the pudendal sensory activity in response to arbitrary profiles of urethral flows. These results describe the properties and function of urethral afferents that are necessary to understand how sensory disruption manifests in lower urinary tract pathophysiology. Key points Sensory information from the urethra is essential to maintain continence and to achieve efficient micturition and when compromised by disease or injury can lead to substantial loss of function. Despite the key role urethral sensory information plays in the lower urinary tract, the relationship between physiological urethral stimuli, such as fluid flow, and the neural sensory response is poorly understood. This work systematically quantifies pudendal afferent responses to a range of fluid flows in the urethra in vivo and describes a previously unknown long-term neural accommodation phenomenon in these afferents. We present a compact mechanistic mathematical model that reproduces the pudendal sensory activity in response to urethral flow. These results have implications for understanding urinary tract dysfunction caused by neuropathy or nerve damage, such as urinary retention or incontinence, as well as for the development of strategies to mitigate the symptoms of these conditions. PMID:26041695
[Effect of modified Badenoch operation on the treatment of posterior urethral stricture].
Wang, Ping-xian; Zhang, Gen-pu; Huang, Chi-bing; Fan, Ming-qi; Feng, Jia-yu; Xiao, Ya
2012-02-01
To determine the effects of modified pull-through operation (Badenoch operation) on the treatment of posterior urethral stricture. From September 2001 to December 2010 traditional pull-through operation was Modified for two times in our center. A total of 129 patients with posttraumatic posterior urethral stricture resulting from pelvic fracture injury underwent the modified urethral pull-through operation. Stricture length was 1.5 to 5.3 cm (mean 2.9 cm). Of the patients 43 had undergone at least 1 previous failed management for stricture. In phase 1 (from September 2001 to January 2008), the improving items include: (1) The distal urethral end was stitched and tied to the catheter. (2) As catheter was inserted into bladder and 20 ml water was injected into catheter balloon, the distal urethral end was fixed in the proximal urethra and an overlaying of 1.5 cm was formed between the two ends. (3) Three weeks later, it was tried to insert the catheter to bladder. After the urethral stump necrosis and the catheter separating from the urethra, the catheter was removed. In phase 2 (from February 2008 to December 2010), based on the above, irrigating catheter was used. After the surgery, urethra was irrigated with 0.02% furacillin solution through the catheter 3 times a day. All patients were followed up for at least 6 months. If patients had no conscious dysuria and maximum urinary flow rate (Qmax) > 15 ml/s, the treatment was considered successful. All complications were recorded. In phase 1, the 96 patients (101 times) underwent the procedure. The treatment was successful in 88 patients (success rate 92%). Within 1 to 13 days after removal of the catheter, urethral stricture was recurred in 8 patients. They had to undergo cystostomy once more for 3 to 11 months before reoperation (the 3 patients' reoperation was in phase 2). The 8 cases were treated successfully. In phase 2, 33 patients (total 36 times) underwent the procedure. One patient was failed (success rate 97%). The actual follow-up time is 7 to 93 months (An average of 37.6 months). Qmax is (22 ± 5) ml/s. No complications such as urinary incontinence, erectile pain, urinary shortening happened. The modified urethral pull-through operation is effective for the surgical treatment of posttraumatic posterior urethral stricture. It has a high success rate with durable long-term results. Complications are few. The procedure is simple, less demanding and especially suitable in patients who had previously undergone failed surgical treatments.
Seismic retrofit of spliced sleeve connections for precast bridge piers.
DOT National Transportation Integrated Search
2017-03-01
Grouted Splice Sleeve (GSS) connectors are being considered for connecting bridge columns, footings, and pier caps in Accelerated Bridge Construction (ABC). A repair technique for precast reinforced concrete bridge column-to-footing and column-to-pie...
Park, Sin Hyung; Choi, Yeong-Jin; Moon, Sang Won; Lee, Byung Hoon; Shim, Jin-Hyung; Cho, Dong-Woo; Wang, Joon Ho
2018-01-01
To investigate the efficacy of the insertion of 3-dimensional (3D) bio-printed scaffold sleeves seeded with mesenchymal stem cells (MSCs) to enhance osteointegration between the tendon and tunnel bone in anterior cruciate ligament (ACL) reconstruction in a rabbit model. Scaffold sleeves were fabricated by 3D bio-printing. Before ACL reconstruction, MSCs were seeded into the scaffold sleeves. ACL reconstruction with hamstring tendon was performed on both legs of 15 adult rabbits (aged 12 weeks). We implanted 15 bone tunnels with scaffold sleeves with MSCs and implanted another 15 bone tunnels with scaffold sleeves without MSCs before passing the graft. The specimens were harvested at 4, 8, and 12 weeks. H&E staining, immunohistochemical staining of type II collagen, and micro-computed tomography of the tunnel cross-sectional area were evaluated. Histologic assessment was conducted with a histologic scoring system. In the histologic assessment, a smooth bone-to-tendon transition through broad fibrocartilage formation was identified in the treatment group, and the interface zone showed abundant type II collagen production on immunohistochemical staining. Bone-tendon healing histologic scores were significantly higher in the treatment group than in the control group at all time points. Micro-computed tomography at 12 weeks showed smaller tibial (control, 9.4 ± 0.9 mm 2 ; treatment, 5.8 ± 2.9 mm 2 ; P = .044) and femoral (control, 9.6 ± 2.9 mm 2 ; treatment, 6.0 ± 1.0 mm 2 ; P = .03) bone-tunnel areas in the treated group than in the control group. The 3D bio-printed scaffold sleeve with MSCs exhibited excellent results in osteointegration enhancement between the tendon and tunnel bone in ACL reconstruction in a rabbit model. If secure biological healing between the tendon graft and tunnel bone can be induced in the early postoperative period, earlier, more successful rehabilitation may be facilitated. Three-dimensional bio-printed scaffold sleeves with MSCs have the potential to accelerate bone-tendon healing in ACL reconstruction. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Anterior Urethral Valve: Uncommon Association with Renal Duplicity.
Salem, Amina Ben; Mazhoud, Ines; Laamiri, Rachida; Salem, Randa; Laajili, Hayet; Sahnoun, Lassaad; Hafsa, Chiraz
2017-01-01
Anterior urethral valves (AUVs) is an unusual cause of congenital obstruction of the male urethra, being 15-30 times less common than posterior urethral valves. We present a case of AUV diagnosed at 24th gestational week. Ultrasonography and fetal MRI revealed hydronephrotic kidneys with ureteral duplicity, a distended bladder and perineal cystic mass which confirmed dilated anterior urethra in a male fetus. Diagnosis was confirmed postnatally by voiding cystourethrogram and surgery.
Penile fracture with urethral trauma.
de Carvalho, Arlindo Monteiro; de Melo, Fábio Martinez; Félix, Gabriella Alves de Lima; Sarmento, Juliana Fernandes; Capriglione, Maria Luisa Dutra
2013-01-01
We reported a case of a twenty-nine-year-old male who presented a penile fracture associated with urethral injury caused by a sexual intercourse. An ideal anamnesis and a special physical examination were determinant to correct diagnostics. Ultrasonography and uretrocistography must be performed for confirmation. The treatment is based on the presence of associated urethral injury. The surgical repair of cavernous body and urethra can produce good results, with a favorable prognosis and minimal rate of complications.
Pelvic fracture and associated urologic injuries.
Brandes, S; Borrelli, J
2001-12-01
Successful management of patients with major pelvic injuries requires a team approach including orthopedic, urologic, and trauma surgeons. Each unstable pelvic disruption must be treated aggressively to minimize complications and maximize long-term functional outcome. Commonly associated urologic injuries include injuries of the urethra, corpora cavernosa (penis), bladder, and bladder neck. Bladder injuries are usually extraperitoneal and result from shearing forces or direct laceration by a bone spicule. Posterior urethral injuries occur more commonly with vertically applied forces, which typically create Malgaigne-type fractures. Common complications of urethral disruption are urethral stricture, incontinence, and impotence. Acute urethral injury management is controversial, although it appears that early primary realignment has promise for minimizing the complications. Impotence after pelvic fracture is predominantly vascular in origin, not neurologic as once thought.
Welding fixture for nuclear fuel pin cladding assemblies
Oakley, D.J.; Feld, S.H.
1984-02-22
A welding fixture is described for locating a driver sleeve about the open end of a nuclear fuel pin cladding. The welding fixture includes a holder provided with an open cavity having shoulders for properly positioning the driver sleeve, the end cap, and a soft, high temperature resistant plastic protective sleeve that surrounds a portion of the end cap stem. Ejected contaminant particles spewed forth by closure of the cladding by pulsed magnetic welding techniques are captured within a contamination trap formed in the holder for ultimate removal and disposal of contaminating particles along with the holder.
Status of the steam generator tube circumferential ODSCC degradation experienced at the Doel 4 plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roussel, G.
1997-02-01
Since the 1991 outage, the Doel Unit 4 nuclear power plant is known to be affected by circumferential outside diameter intergranular stress corrosion cracking at the hot leg tube expansion transition. Extensive non destructive examination inspections have shown the number of tubes affected by this problem as well as the size of the cracks to have been increasing for the three cycles up to 1993. As a result of the high percentage of tubes found non acceptable for continued service after the 1993 in-service inspection, about 1,700 mechanical sleeves were installed in the steam generators. During the 1994 outage, allmore » the tubes sleeved during the 1993 outage were considered as potentially cracked to some extent at the upper hydraulic transition and were therefore not acceptable for continued service. They were subsequently repaired by laser welding. Furthermore all the tubes not sleeved during the 1993 outage were considered as not acceptable for continued service and were repaired by installing laser welded sleeves. During the 1995 outage, some unexpected degradation phenomena were evidenced in the sleeved tubes. This paper summarizes the status of the circumferential ODSCC experienced in the SG tubes of the Doel 4 plant as well as the other connected degradation phenomena.« less
Effect of insulator sleeve material on the x-ray emission from a plasma focus device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hussain, S.; Badar, M. A.; Shafiq, M.
The effect of insulator sleeve material on x-ray emission from a 2.3 kJ Mather type plasma focus device operated in argon-hydrogen mixture is investigated. The time and space resolved x-ray emission characteristics are studied by using a three channel p-i-n diode x-ray spectrometer and a multipinhole camera. The x-ray emission depends on the volumetric ratio of argon-hydrogen mixture as well as the filling pressure and the highest x-ray emission is observed for a volumetric ratio 40% Ar to 60%H{sub 2} at 2.5 mbar filling pressure. The fused silica insulator sleeve produces the highest x-ray emission whereas nonceramic insulator sleeves suchmore » as nylon, Perspex, or Teflon does not produce focus or x-rays. The pinhole images of the x-ray emitting zones reveal that the contribution of the Cu K{alpha} line is weak and plasma x-rays are intense. The highest plasma electron temperature is estimated to be 3.3 and 3.6 keV for Pyrex glass and fused silica insulator sleeves, respectively. It is speculated that the higher surface resistivity of fused silica is responsible for enhanced x-ray emission and plasma electron temperature.« less
Liang, Weiqiang; Ji, Chenyang; Chen, Yuhong; Zhang, Ganling; Zhang, Jiaqi; Yao, Yuanyuan; Zhang, Jinming
2016-08-01
To evaluate the effects, particularly the incidence of anastomotic fistula, of a pedicled dartos flap around the urethral orifice in the treatment of urethroplasty of mid-shaft hypospadias. A total of 46 cases of congenital mid-shaft hypospadias were included in this study. The patients ranged in age from 0.7 to 25.4 years and the average was 5.8 years. The patients received penis chordee correction. A transverse preputial island flap was developed for urethral reconstruction. The proximal dartos of the urethral orifice was used to develop a pedicled dartos flap, which was transposed to cover and strengthen neourethral anastomosis. The ventral penile skin defect was repaired by another flap. The 46 patients were examined during follow-up visits for 6 months to 3 years. An anastomotic fistula was observed in one case (2.2 %). Scar healing without fistula was observed in another patient due to poor blood supply to part of the ventral penile skin. No other incidences of fistula, urethral rupture, flap necrosis, wound infections, urinary tract (meatal) stenosis, or urethral diverticulum were observed in the patients. A pedicled dartos flap around the urethral orifice can take advantage of well-vascularized local tissue to add a protective layer to the proximal aspect of the neourethral anastomosis for reducing the incidence of anastomotic fistula in mid-shaft hypospadias repair using a transverse preputial island flap. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
[Neo-urethroclitoroplasty according to Petrovic].
Trombetta, Carlo; Liguori, Giovanni; Benvenuto, Sara; Petrovic, Milos; Napoli, Renata; Umari, Paolo; Rizzo, Michele; Zordani, Alessio
2011-01-01
We present a refinement to our original technique in MtF gender reassignment surgery. Our goal was to construct a neoclitoris, which is wet and covered with urethral neoprepuce. Since 1995 more than 300 transgender MtF patients have been operated at our institution. Our refinement has been applied to 12 cases and showed both excellent functional and cosmetic results during midterm follow-up. During 2010 several sex reassignment surgeries have been performed using our new technique that includes: bilateral orchiectomy, removal of corpora cavernosa of the penis, formation of the neourethra with neomeatus, neovaginoplasty by inversion of penoscrotal skin flaps, construction of the neoclitoris with preservation of the neurovascular bundle and exterior vulva formation. The refinement consists in creating a neoclitoris embedded in urethral mucosa using urethral flaps. These flaps are in continuity with the previously spatulated urethra. The urethral plate is further incised distally in a Y fashion. The urethral flaps are sutured around the neoclitoris to form a neo-urethroclitoris covered by urethral neoprepuce, which resembles a real female clitoris. The neoclitoris is positioned in the anatomical position of the male suspensory ligament of the penis that is also the natural anatomical position of the female clitoris. With this method we are able to construct a clitoris with a normal sensitivity embedded in urethral mucosa that remains wet and hairless. It can be easily stimulated during sexual intercourse, as most of the patients reported great satisfaction and ability to reach orgasm. We want to emphasize how both the cosmetic results and functionality of the neovagina and neoclitoris are important in this type of surgery for the quality of life of our patients. We are still far from a perfect surgical solution, but we are further improving our technique and follow our aims step by step.
Pizzoferrato, Anne-Cécile; Fauconnier, Arnaud; Bader, Georges; de Tayrac, Renaud; Fort, Julie; Fritel, Xavier
2016-07-01
Obstetric trauma during childbirth is considered a major risk factor for postpartum urinary incontinence (UI), particularly stress urinary incontinence. Our aim was to investigate the relation between postpartum UI, mode of delivery, and urethral descent, and to define a group of women who are particularly at risk of postnatal UI. A total of 186 women were included their first pregnancy. Validated questionnaires about urinary symptoms during pregnancy, 2 and 12 months after delivery, were administered. Urethral descent was assessed clinically and by ultrasound at inclusion. Multivariate logistic regression analysis was used to determine the risk factors for UI during pregnancy, at 2 months and 1 year after first delivery. The prevalence of UI was 38.6, 46.5, 35.6, and 34.4 % at inclusion, late pregnancy, 2 months postpartum, and 1 year postpartum respectively. No significant association was found between UI at late pregnancy and urethral descent assessed clinically or by ultrasound. The only risk factor for UI at 2 months postpartum was UI at inclusion (OR 6.27 [95 % CI 2.70-14.6]). The risk factors for UI at 1 year postpartum were UI at inclusion (6.14 [2.22-16.9]), body mass index (BMI), and urethral descent at inclusion, assessed clinically (7.21 [2.20-23.7]) or by ultrasound. The mode of delivery was not associated with urethral descent. Prenatal urethral descent and UI during pregnancy are risk factors for UI at 1 year postpartum. These results indicate that postnatal UI is more strongly influenced by susceptibility factors existing before first delivery than by the mode of delivery.
Sensitivity of Gram stain in the diagnosis of urethritis in men.
Orellana, M Angeles; Gómez-Lus, M Luisa; Lora, David
2012-06-01
Acute urethritis is among the most common types of sexually transmitted diseases in men. The diagnosis usually requires microscopic evidence of urethritis, but sometimes urethral pathogens are detected in asymptomatic men without such evidence. The aims of this study were to assess the sensitivity of Gram stain in men with urethral symptoms and to relate it to the microorganisms isolated. Between January 2006 and December 2007, 491 urethral samples were analysed. The authors assessed the presence of leukocytes by Gram stain and tested specifically for Chlamydia trachomatis, Ureaplasma urealyticum, Mycoplasma hominis and Trichomonas vaginalis, as well as analysing the results of conventional culture. The percentages of positive samples as a function of Gram category were two or less polymorphonuclear leukocytes (PMNLs)/high-power field (HPF) 25% (92/364), three to four PMNLs/HPF 32% (18/57) and five or more PMNLs/HPF 54% (38/70). Classing samples with more than two PMNLs/HPF as positive, the sensitivity, specificity and positive likelihood ratio for Gram stain were 38% (95% CI 30 to 46), 79% (95% CI 75 to 84) and 1.8 (95% CI 1.4 to 2.4), respectively. On the other hand, taking as positive five or more PMNLs/HPF, the sensitivity, specificity and positive likelihood ratio for Gram stain were 26% (95% CI 18 to 33), 91% (95% CI 87 to 94) and 2.7 (95% CI 1.8 to 4.2), respectively. The sensitivity of Gram stain to Neisseria gonorrhoeae, Chlamydia trachomatis and Ureaplasma urealyticum were 80% (95% CI 64 to 96), 23% (95% CI 8 to 39) and 11% (95% CI 2 to 20), respectively. The low sensitivity of Gram stain means that negative results do not exclude the presence of urethritis in symptomatic patients.
Medication Effects on Periurethral Sensation and Urethral Sphincter Activity
Greer, W. Jerod; Gleason, Jonathan L.; Kenton, Kimberly; Szychowski, Jeff M.; Goode, Patricia S; Richter, Holly E
2014-01-01
Aim To characterize urethral neuromuscular function before and 2 weeks after medication therapy. Methods Premenopausal women without lower urinary tract symptoms were randomly allocated to one of six medications for 2 weeks (pseudoephedrine ER 120mg, imipramine 25mg, cyclobenzaprine 10mg, tamsulosin 0.4mg, solifenacin 5mg or placebo). At baseline and after medication, participants underwent testing: quantitative concentric needle EMG (CNE) of the urethral sphincter using automated Multi-Motor Unit Action Potential (MUP) software; current perception threshold (CPT) testing to measure periurethral sensation; and standard urodynamic pressure flow studies (PFS). Nonparametric tests were used to compare pre-post differences. Results 56 women had baseline testing; 48 (85.7%) completed follow-up CNE, and 49 (87.5%) completed follow-up CPT and PFS testing. Demographics showed no significant differences among medication groups with respect to age (mean 34.3 ± 10.1), BMI (mean 31.8 ± 7.5), parity (median 1, range 0–7), or race (14% Caucasian, 80% African American). PFS parameters were not significantly different within medication groups. No significant pre-post changes in CNE values were noted; however, trends in amplitudes were in a direction consistent with the expected physiologic effect of the medications. With CPT testing, a trend toward increased urethral sensation at the 5 Hz stimulation level, was observed following treatment with pseudoephedrine (0.15 to 0.09 mA at 5Hz; P=0.03). Conclusion In women without LUTS, pseudoephedrine improved urethral sensation, but not urethral neuromuscular function on CNE or pressure flow studies. Imipramine, cyclobenzaprine, tamsulosin, solifenacin, and placebo did not change urethral sensation or neuromuscular function. PMID:25185603
Urethral caruncle: a lesion related to IgG4-associated sclerosing disease?
Williamson, Sean R; Scarpelli, Marina; Lopez-Beltran, Antonio; Montironi, Rodolfo; Conces, Miriam R; Cheng, Liang
2013-07-01
Urethral caruncle is a benign, polypoid urethral mass that occurs almost exclusively in postmenopausal women. Despite that these lesions are routinely managed with topical medications or excision, their pathogenesis is not well understood. We investigated the possibilities of autoimmune, viral and inflammatory myofibroblastic proliferations as possible aetiologies. In 38 patients with urethral caruncle, we utilised immunohistochemistry for immunoglobulin G (IgG) and IgG4 to assess for a potential autoimmune aetiology. Immunohistochemistry was performed in nine patients for Epstein-Barr virus, BK virus, human herpesvirus 8, human papillomavirus, adenovirus and anaplastic lymphoma kinase. Four patients (11%) showed infiltrates of ≥50 IgG4-positive plasma cells per high power field, of which all showed an IgG4 to IgG ratio greater than 40%. A statistically significant difference (p<0.01) was detected in the mean number of IgG4-positive cells (14.73 per high power field) compared with control benign urethral specimens (mean, 1.19). One patient with increased counts below this threshold had rheumatoid arthritis; none had documented autoimmune pancreatitis or other known manifestations of systemic IgG4-related sclerosing disease. All lesions showed negative reactions for the viral and inflammatory myofibroblastic markers. Urethral caruncle is a benign inflammatory and fibrous polypoid urethral mass of unclear aetiology. It appears unrelated to viral infection and lacks the abnormal expression of anaplastic lymphoma kinase protein, as seen in inflammatory myofibroblastic tumours. Increased numbers of IgG4-positive plasma cells in a subset of lesions raise the possibility that some cases may be related to the autoimmune phenomena of IgG4-associated disease.
Olajide, Abimbola Olaniyi; Olajide, Folakemi Olajumoke; Kolawole, Oladapo Adedayo; Oseni, Ismaila; Ajayi, Adewale Idowu
2013-01-01
Background Management of urethral stricture has evolved over the years with better understanding of the pathology, advancement in imaging, and introduction of several techniques of urethral reconstruction. In sub-Saharan Africa, advancement in management of urethral stricture may not be comparable with what obtained in most developed nations because of problems like late presentation and persistence of rare complications still reported in recent literature from the region. Objectives We set to evaluate the challenges faced by urologists involved in the management of urethral strictures in Osogbo, a poor resource community in south western Nigeria. Patients and Methods A retrospective study was performed in the urology unit of Ladoke Akintola University of Technology Teaching Hospital, Osogbo, Nigeria between July 2007 and July 2012. Information was retrieved from patients’ clinical notes and analyzed using statistical package for social sciences (SPSS) version 16.0. Results Eighty-four patients were treated during the period of study, their ages ranged between 19 and 89 years with the mean age of 52.3 years. The mean duration of symptoms before presentation was 3 years and 1 month. Inflammation resulting from sexually transmitted infection was the commonest etiology and more than 50% of the patients presented with complications. Sixteen patients (19.1%) received no treatment due to lack of fund. More than 90% were dependent, unemployed or underemployed. Single stage reconstruction by urethral substitution was the commonest form of repair with the restenosis rate of 4.4%. Conclusions Prevalent socio-cultural and economic situation in south western Nigeria have added some peculiar challenges to the management of urethral stricture in the region. PMID:24693504
Routt, M L; Simonian, P T; Defalco, A J; Miller, J; Clarke, T
1996-05-01
Associated urological and orthopedic injuries of the pelvic ring are complex with numerous potential complications. These patients are treated optimally using a team approach. The combined expertise is not only helpful initially when managing these difficult patients, but also later as problems develop. This study describes a treatment protocol and reports the early results of 23 patients with unstable pelvic fractures and associated bladder or urethral disruptions, or both, treated surgically with open reduction and internal fixation of the anterior pelvic ring injuries at the same anesthetic and using the same surgical exposure as the urethral realignments or bladder repairs or both. Early complications occurred in four patients (17%): one patient sustained a fifth lumbar nerve injury caused by the pelvic reduction procedure, and three patients had anterior pelvic internal fixation failures. Late complications occurred in eight patients (35%). There was one deep wound infection (4.3%) that presented 6 weeks after injury. Late urological complications occurred in seven patients (30%). Four of the nine male patients with urethral disruptions had urethral stricture after their primary urethral realignments (44%). Three of the 18 male patients admitted to impotence (16.7%). One of the three had a residual thoracic paraplegia caused by a burst fracture. One of the five female patients had urinary incontinence and required a bladder suspension operation to restore normal function (20%). A low infection rate can be expected despite the use of internal fixation. Early urethral "indirect" realignments avoid more difficult delayed open repairs; however, late urological complication rates are still high. Early "direct" bladder repairs are easily performed at the time of anterior pelvic open reduction and internal fixation. Suprapubic tubes are not necessary to adequately divert the urine when large diameter urethral catheters are used in these patients.
Cannon, Tracy W; Lee, Ji Youl; Somogyi, George; Pruchnic, Ryan; Smith, Christopher P; Huard, Johnny; Chancellor, Michael B
2003-11-01
To study the physiologic outcome of allogenic transplant of muscle-derived progenitor cells (MDPCs) in the denervated female rat urethra. MDPCs were isolated from muscle biopsies of normal 6-week-old Sprague-Dawley rats and purified using the preplate technique. Sciatic nerve-transected rats were used as a model of stress urinary incontinence. The experimental group was divided into three subgroups: control, denervated plus 20 microL saline injection, and denervated plus allogenic MDPCs (1 to 1.5 x 10(6) cells) injection. Two weeks after injection, urethral muscle strips were prepared and underwent electrical field stimulation. The pharmacologic effects of d-tubocurare, phentolamine, and tetrodotoxin on the urethral strips were assessed by contractions induced by electrical field stimulation. The urethral tissues also underwent immunohistochemical staining for fast myosin heavy chain and CD4-activated lymphocytes. Urethral denervation resulted in a significant decrease of the maximal fast-twitch muscle contraction amplitude to only 8.77% of the normal urethra and partial impairment of smooth muscle contractility. Injection of MDPCs into the denervated sphincter significantly improved the fast-twitch muscle contraction amplitude to 87.02% of normal animals. Immunohistochemistry revealed a large amount of new skeletal muscle fiber formation at the injection site of the urethra with minimal inflammation. CD4 staining showed minimal lymphocyte infiltration around the MDPC injection sites. Urethral denervation resulted in near-total abolishment of the skeletal muscle and partial impairment of smooth muscle contractility. Allogenic MDPCs survived 2 weeks in sciatic nerve-transected urethra with minimal inflammation. This is the first report of the restoration of deficient urethral sphincter function through muscle-derived progenitor cell tissue engineering. MDPC-mediated cellular urethral myoplasty warrants additional investigation as a new method to treat stress urinary incontinence.
Cassadó Garriga, Jordi; Pessarrodona Isern, Antoni; Rodríguez Carballeira, Monica; Pallarols Badia, Mar; Moya Del Corral, Manuela; Valls Esteve, Marta; Huguet Galofré, Eva
2017-09-01
The pathophysiological mechanism of incontinence is multifactorial. We evaluated the role of 3D-4D ultrasound in the assessment of the fascial supports of the urethra and the urethral sphincter complex (USC) for diagnosing stress urinary incontinence. Observational case-control study in women with and without stress urinary incontinence attending a urogynecology service and a general gynecology service. All women were interviewed, examined, and classified according to the Pelvic Organ Prolapse Quantification (POP-Q) and underwent a 3D-4D translabial ultrasound. Fascial supports of the urethra were assessed by tomographic ultrasound and were considered to be intact or absent if it was possible to identify them at eight levels on each side, urethral mobility was assessed on maximal Valsalva in sagittal section and the length and volume of the USC at rest and on maximal Valsalva were determined using the Virtual Organ Computer-aided Analysis (VOCAL) program. Variables were compared between continent and incontinent women. A total of 173 women were examined, 78 continent and 95 incontinent. There was a significant difference in urethral mobility between continent and incontinent women (12.82 mm vs. 21.85 mm, P < 0.001), but there was no significant difference in the percentage of supports affected (43.27% vs. 35.94%, P < 0.070). The length of the USC at rest was significantly shorter (P < 0.001) in incontinent patients. Ultrasound evaluation of urethral supports does not discriminate between continent and incontinent women. However, the length of the USC at rest was shorter and urethral mobility was higher in incontinent women. Neurourol. Urodynam. 9999:XX-XX, 2016. © 2016 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Effects of birth trauma and estrogen on urethral elastic fibers and elastin expression.
Lin, Guiting; Ning, Hongxiu; Wang, Guifang; Banie, Lia; Lue, Tom F; Lin, Ching-Shwun
2010-10-01
To investigate the effects of birth trauma and estrogen on urethral elastic fibers and elastin expression. Pregnant rats were subjected to sham operation (Delivery-only), DVDO (delivery, vaginal distension and ovariectomy), or DVDO + E₂ (estrogen). At 2, 4, 8, or 12 weeks, their urethras were harvested for elastic fiber staining and reverse transcription-polymerase chain reaction analysis. Urethral cells were treated with transforming growth factor- β1 (TGFβ1) and/or estrogen and analyzed for elastin mRNA expression. Urethral cells were also examined for the activities of Smad1- and Smad3/4-responsive elements in response to TGFβ1 and estrogen. At 8 weeks post-treatment, the urethras of DVDO rats had fewer and shorter elastic fibers when compared with Delivery-only rats, and those of DVDO + E₂ rats had fewer and shorter elastic fibers when compared with DVDO rats. Elastin mRNA was expressed at low levels in Delivery-only rats and at increasingly higher levels in DVDO rats at 2, 4, and 8 weeks but at sharply lower levels in DVDO + E₂ rats when compared with DVDO rats at 8 weeks. Urethral cells expressed increasingly higher levels of elastin mRNA in response to increasing concentrations of TGFβ1 up to 1 ng/mL. At this TGFβ1 concentration, urethral cells expressed significantly lower levels of elastin mRNA when treated with estrogen before or after TGFβ1 treatment. Both Smad1- and Smad3/4-responsive elements were activated by TGFβ1 and such activation was suppressed by estrogen. Birth trauma appears to activate urethral elastin expression via TGFβ1 signaling. Estrogen interferes with this signaling, resulting in improper assembly of elastic fibers. Copyright © 2010 Elsevier Inc. All rights reserved.
Photodynamic therapy of urethral condylomata acuminata using topically 5-aminolevulinic acid
NASA Astrophysics Data System (ADS)
Wang, Xiuli; Wang, Hongwei; Wang, Haishan; Xu, Shizheng; Liao, Kanghuang; Hillemanns, Peter
2005-07-01
Background Electrocoagulation and laser evaporation for urethral condylomata acuminata have high recurrence rates and can be associated with urethral malformations. Objective To investigate the effect of photodynamic therapy (PDT) with topical 5-aminolevulinic acid (ALA) on urethral condylomata acuminata and to examine the histological changes in lesions of condylomata acuminata after ALA-PDT. Methods One hundred and sixty-four urethral condylomata patients were given topical ALA followed by intraurethral PDT through a cylindrical fiber. Among the cases, 16 penile and vulval condylomatous lesions in 11 patients were treated with topical ALA-PDT at same time. After the treatment, biopsy specimens were collected from the 16 penile and vulval lesions. The histological changes were then evaluated by light microscope and electron microscope. Results The complete response rate for urethral condylomata by topical ALA-PDT was 95.12% and the recurrence rate was 5.13% after 6 to 24 months follow-up. Keratinocytes in middle and upper layers of the epidermis with marked vacuolation and some necrocytosis were detected one and three hours after PDT. Necrosis in all layers of the epidermis was noted five hours after PDT by microscopy. In electron microscopy of kerationcytes, distinct ultrastructural abnormalities of mitochondrion, endoplasmic reticulum and membrane damage were observed. Apoptotic bodies were detected three hours after PDT and a large number of the keratinocytes exhibited necrosis five hours after PDT by electron microscope. Conclusions Results suggests that topical ALA-PDT is a simple, effective, relatively safe, less recurrent and comparatively well tolerated treatment for urethral condylomata acuminata. The mechanisms might be that ALA-PDT could trigger apoptotic process and necrosis in the HPV infected keratinocytes. Key words:
Medical Surveillance Monthly Report (MSMR). Volume 16, Number 3, March 2009
2009-03-01
Gonorrhea Syphilis‡ Urethritis§ Cold Heat 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 NORTH ATLANTIC Washington, DC... Gonorrhea Syphilis‡ Urethritis§ Cold Heat 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 2008 2009 NATIONAL CAPITOL AREA NNMC...Sexually transmitted Environmental Lyme disease Malaria Chlamydia Gonorrhea Syphilis‡ Urethritis§ Cold Heat 2008 2009 2008 2009 2008 2009 2008 2009 2008
Phosphoinositide-Driven Epithelial Proliferation in Prostatic Inflammation
2009-04-01
IL-1β expression is localized to the urethral urothelium during development, and little or no expression is observed in the developing prostatic...ducts [Figure 3B]. By comparison, IL-1α expression is found both in the urethral urothelium and in the developing prostatic ducts [Figure 3A]. In...adult [C]. Hyperplasia was induced by E. coli for 5 days. In contrast, IL-1β [B,D] expression is localized to the urethral urothelium at P10 [B] and
Gamé, Xavier; Allard, Julien; Escourrou, Ghislaine; Gourdy, Pierre; Tack, Ivan; Rischmann, Pascal; Arnal, Jean-François; Malavaud, Bernard
2008-03-01
Estrogens are known to modulate lower urinary tract (LUT) trophicity and neuronal nitric oxide synthase (nNOS) expression in several organs. The aim of this study was to explore the effects of endogenous and supraestrus levels of 17beta-estradiol (E2) on LUT and urethral nNOS expression and function. LUT function and histology and urethral nNOS expression were studied in adult female mice subjected either to sham surgery, surgical castration, or castration plus chronic E2 supplementation (80 microg.kg(-1).day(-1), i.e., pregnancy level). The micturition pattern was profoundly altered by long-term supraestrus levels of E2 with decreased frequency paralleled by increased residual volumes higher than those of ovariectomized mice. Urethral resistance was increased twofold in E2-treated mice, with no structural changes in urethra, supporting a pure tonic mechanism. Acute nNOS inhibition by 7-nitroindazole decreased frequency and increased residual volumes in ovariectomized mice but had no additive effect on the micturition pattern of long-term supraestrus mice, showing that long-term supraestrus E2 levels and acute inhibition of nNOS activity had similar functional effects. Finally, E2 decreased urethral nNOS expression in ovariectomized mice. Long-term supraestrus levels of E2 increased urethral tone through inhibition of nNOS expression, whereas physiological levels of E2 had no effect.
Xue, Jing-Dong; Xie, Hong; Fu, Qiang; Feng, Chao; Guo, Hui; Xu, Yue-Min
2016-01-01
To present an improved tubularized flap (ITF) technique and report the outcome of single-stage urethroplasty using preputial/penile skin flaps (PSFs) for the treatment of obliterative anterior urethral strictures (AUSs). From January 2000 to June 2012, 42 cases of obliterative AUS (3-14 cm, mean 6.38 cm) with urethral plate unsalvageable were treated using PSF-ITF urethroplasty including longitudinal skin flap, circular island flap, L-flap, Q-flap. Patients were divided into 3 groups: pendulous urethral stricture (Group A), bulbar urethral stricture (Group B) and panurethral strictures (Group C). Patients were followed up by uroflowmetry, urethrography and ureteroscope when necessary. The mean follow-up in these patients was 65 months (range 36 months-15 years). The primary success rates at 3-year follow-up were 75, 75 and 60% for Groups A, B and C, respectively. The overall success rates were 85, 83 and 70% with the remedial measure of a single visual internal urethrotomy at 3-year follow-up. A total 60% of the patients in the study completed more than 5 years of follow-up with no additional recurrence. Improved tubularized preputial/PSF urethroplasty with relatively high overall satisfaction is a novel technique for treatment of AUS when there is inadequate urethral plate or obliterative defects. © 2016 S. Karger AG, Basel.
Dorsal onlay lingual mucosal graft urethroplasty for urethral strictures in women.
Sharma, Girish K; Pandey, Ashwani; Bansal, Harbans; Swain, Sameer; Das, Suren K; Trivedi, Sameer; Dwivedi, Udai S; Singh, Pratap B
2010-05-01
To describe the technique and results of dorsal onlay lingual mucosal graft (LMG) urethroplasty for the definitive management of urethral strictures in women. In all, 15 women (mean age 42 years) with a history suggestive of urethral stricture who had undergone multiple urethral dilatations and/or urethrotomy were selected for dorsal onlay LMG urethroplasty after thorough evaluation, from October 2006 to March 2008. After a suprameatal inverted-U incision, the dorsal aspect of the urethra was dissected and urethrotomy was done at the 12 o'clock position across the strictured segment. Tailored LMG harvested from the ventrolateral aspect of the tongue was then sutured to the urethrotomy wound over an 18 F silicone catheter. The preoperative mean maximum urinary flow rate of 7.2 mL/s increased to 29.87 mL/s, 26.95 mL/s and 26.86 mL/s with a 'normal' flow rate curve at 3, 6 and 12 months follow-up, respectively. One patient at the 3-month follow-up had submeatal stenosis and required urethral dilatation thrice at monthly intervals. At the 1-year follow-up, none of the present patients had any neurosensory complications, urinary incontinence, or long-term functional/aesthetic complication at the donor site. LMG urethroplasty using the dorsal onlay technique should be offered for correction of persistent female urethral stricture as it provides a simple, safe and effective approach with durable results.
... that cause this condition are E coli, chlamydia , gonorrhea . These bacteria also cause urinary tract infections and ... women only) Urinalysis and urine cultures Tests for gonorrhea , chlamydia , and other sexually transmitted illnesses (STI) Urethral ...
Nguyen, Ninh T; Nguyen, Brian; Gebhart, Alana; Hohmann, Samuel
2013-02-01
Laparoscopic sleeve gastrectomy is gaining popularity in the US; however, there has been no study examining the use of sleeve gastrectomy at a national level and its impact on the use of other bariatric operations. The aim of this study was to examine contemporary changes in use and outcomes of bariatric surgery performed at academic medical centers. Using ICD-9 diagnosis and procedure codes, clinical data obtained from the University HealthSystem Consortium database for all bariatric procedures performed for the treatment of morbid obesity between October 1, 2008 and September 30, 2012 were reviewed. Quartile trends in use for the 3 most commonly performed bariatric operations were examined, and a comparison of perioperative outcomes between procedures was performed within a subset of patients with minor severity of illness. A total of 60,738 bariatric procedures were examined. In 2008, the makeup of bariatric surgery consisted primarily of gastric bypass (66.8% laparoscopic, 8.6% open), followed by laparoscopic gastric banding (23.8%). In 2012, there was a precipitous increase in use of laparoscopic sleeve gastrectomy (36.3 %), with a concurrent reduction in the use of laparoscopic (56.4%) and open (3.2%) gastric bypass, and a major reduction in laparoscopic gastric banding (4.1%). The length of hospital stay, in-hospital morbidity and mortality, and costs for laparoscopic sleeve gastrectomy were found to be between those of laparoscopic gastric banding and laparoscopic gastric bypass. Within the context of academic medical centers, there has been a recent change in the makeup of bariatric surgery. There has been an increase in the use of laparoscopic sleeve gastrectomy, which has had an impact primarily on reducing the use of laparoscopic adjustable gastric banding. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Method for hot press forming articles
Baker, Robert R.; Hartsock, Dale L.
1982-01-01
This disclosure relates to an improved method for achieving the best bond strength and for minimizing distortion and cracking of hot pressed articles. In particular, in a method for hot press forming both an outer facing circumferential surface of and an inner portion of a hub, and of bonding that so-formed outer facing circumferential surface to an inner facing circumferential surface of a pre-formed ring thereby to form an article, the following improvement is made. Normally, in this method, the outside ring is restrained by a restraining sleeve of ring-shaped cross-section having an inside diameter. A die member, used to hot press form the hub, is so-formed as to have an outside diameter sized to engage the inside diameter of the restraining sleeve in a manner permitting relative movement therebetween. The improved method is one in which several pairs of matched restraining sleeve and die member are formed with each matched pair having a predetermined diameter. The predetermined diameter of each matched pair is different from another matched pair by stepped increments. The largest inside diameter of a restraining sleeve is equal to the diameter of the outer facing circumferential surface of the hub. Each pair of the matched restraining sleeve and die member is used to form an article in which an inside hub is bonded to an outside ring. The several samples so-formed are evaluated to determine which sample has the best bond formed between the hub and the ring with the least or no cracking or distortion in the ring portion of the article. Thereafter, the matched restraining sleeve and die member which form the article having the best bonding characteristics and least distortion cracking is then used for repeated formations of articles.
Hospital Variation in Perioperative Complications for Laparoscopic Sleeve Gastrectomy in Michigan
Pradarelli, Jason C.; Varban, Oliver A.; Ghaferi, Amir A.; Weiner, Matthew; Carlin, Arthur M.; Dimick, Justin B.
2015-01-01
Structured Abstract Background Laparoscopic sleeve gastrectomy has recently surpassed gastric bypass and laparoscopic adjustable gastric banding as the most common weight-loss procedure. Previously, substantial concerns existed regarding variation in perioperative safety with bariatric surgery. This study aimed to assess rates of perioperative complications for laparoscopic sleeve gastrectomy across hospitals and in relation to procedure volume. Study Design We analyzed 8,693 patients who underwent laparoscopic sleeve gastrectomy from 2013 through 2014 across 40 hospitals in the Michigan Bariatric Surgery Collaborative. Mixed-effects logistic regression was used to assess hospital variation in risk- and reliability-adjusted rates of overall and serious 30-day complications and their relationship with hospital annual stapling procedure volume (gastric bypass and sleeve gastrectomy). Results Overall, 5.4% of patients experienced perioperative complications. Adjusted rates of overall complications varied three-fold across hospitals, ranging from 3.6% (95% CI, 1.9–6.8%) to 11.0% (95% CI, 7.7–15.5%). Serious complications occurred in just 1.2% of patients and varied minimally. In this analysis, hospital volume was not associated with overall or serious complications. The 1 hospital with significantly lower overall complication rates was high-volume (≥125 procedures/year); however, of the 4 hospitals with significantly higher complication rates, 3 were medium-volume (50–124 procedures/year) and 1 was high-volume. The remaining hospitals were not significantly different than the cohort mean. Conclusions Serious complications among patients undergoing laparoscopic sleeve gastrectomy were relatively infrequent. Rates of overall complications varied widely across Michigan hospitals enrolled in a quality collaborative, although this variation was unrelated to volume standards required for accreditation as a comprehensive bariatric surgery center. PMID:26506567
Thermal characterization of phacoemulsification probes operated in axial and torsional modes.
Zacharias, Jaime
2015-01-01
To analyze temperature increases and identify potential sources of heat generated when sleeved and sleeveless phacoemulsification probes were operated in axial and torsional modes using the Infiniti Vision System with the Ozil torsional handpiece. Phacodynamics Laboratory, Pasteur Ophthalmic Clinic, Santiago, Chile. Experimental study. Two computer-controlled thermal transfer systems were developed to evaluate the contribution of internal metal stress and tip-to-sleeve friction on heat generation during phacoemulsification using axial and torsional ultrasound modalities. Both systems incorporated infrared thermal imaging and used a black-body film to accurately capture temperature measurements. Axial mode was consistently associated with greater temperature increases than torsional mode whether tips were operated with or without sleeves. In tests involving bare tips, axial mode and torsional mode peaked at 51.7°C and 34.2°C, respectively. In an example using sleeved tips in which a 30.0 g load was applied for 1 second, temperatures for axial mode reached 45°C and for torsional mode, 38°C. Friction between the sleeved probe and the incisional wall contributed more significantly to the temperature increase than internal metal stress regardless of the mode used. In all experiments, the temperature increase observed with axial mode was greater than that observed with torsional mode, even when conditions such as power or amplitude and flow rate were varied. Tip-to-sleeve friction was a more dominant source of phaco probe heating than internal metal stress. The temperature increase due to internal metal stress was greater with axial mode than with torsional mode. Dr. Zacharias received research funding from Alcon Laboratories, Inc., to conduct this study. He has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Saber, Alan A; Shoar, Saeed; Khoursheed, Mousa
2017-08-01
Despite its technical simplicity, laparoscopic sleeve gastrectomy (LSG) complications are increasingly reported. Intra-thoracic sleeve migration (ITSM ) is a rare complication after LSG which has been inconsistently addressed in the literature. The purpose of this study was to emphasize ITSM occurrence after LSG and evaluate the perioperative factors associated with its development. Between January and July 2016, LSG patients diagnosed with ITSM at two bariatric surgery departments were identified. Perioperative factors were assessed for all the patients and compared between two groups, LSG alone and LSG with concomitant hiatal hernia (HH) repair (HHR). A total of 19 patients (6 males and 13 females) were included. Central obesity was present in 18 patients (94.7%). Nine patients (47.4%) had concomitant hiatal hernia repair during their original LSG. Post-LSG GERD (94.7%) (38.9% de novo and 61.1% recurrent) and post-LSG constipation (57.9%) were commonly associated with ITSM. Severe refractory GERD was the most common presentation for ITSM (94.7%), followed by epigastric pain (47.4%), persistent nausea/vomiting (36.8%), and dysphagia (21.1%). Time interval between primary LSG and ITSM diagnosis ranged from 1 day to 3 years. Patients with LSG and concomitant HHR presented with higher post-LSG BMI compared to the LSG patients (37 ± 6.4 kg/m 2 vs. 30.1 ± 6.3 kg/m 2 , p = 0.03). All the patients underwent successful reduction of ITSM and subsequent HHR. Central obesity, chronic constipation, post-LSG GERD, and concomitant HHR are commonly seen in post-laparoscopic sleeve gastrectomy intra-thoracic sleeve migration.
Anterior urethral valve associated with posterior urethral valves.
Kajbafzadeh, A M; Jangouk, P; Ahmadi Yazdi, C
2005-12-01
The association of anterior urethral valve (AUV) with posterior urethral valve (PUV) is rare. A 7-month-old infant was presented at a district hospital with episodes of acute pyelonephritis. He was treated medically and a voiding cystourethrogram (VCUG) confirmed bilateral vesico-urethral reflux. The presence of concomitant AUV and PUV was not recognized. He underwent several surgical procedures, which failed. He had reflux recurrence following two antireflux procedures. He had urinary retention after each operation, which was managed by vesicostomy and perineal urethrostomy. At the age of 3.5 years, he was referred to our paediatric urology clinic. Noticing the AUV and PUV in the past VCUG, the valves were fulgurated. Urodynamic study before and 3 months after valve ablation showed a high voiding pressure. VCUG 6 months following ablation showed no reflux, but several uroflowmetric studies showed a staccato and interrupted pattern. Empirical treatment with an alpha-blocker was started. One year after treatment, a repeat VCUG showed no reflux. Uroflowmetry and urodynamic studies returned to normal. The perineal urethrostomy was closed. The child was asymptomatic after 9 months of follow up.
Iosif, S; Ulmsten, U
1981-07-15
Twelve pregnant women were examined by urethral pressure profile measurement and simultaneous urethrocystometry early in pregnancy (weeks 12 to 16), in the thirty-eighth week, and 5 to 7 days after delivery. All patients reported symptoms of stress incontinence starting at an early 5 to 7 days after delivery. All patients reported symptoms of stress incontinence starting at an early gestational age, it was found that that the stress incontinent women, compared to 14 continent, healthy women from whom measurements were obtained earlier, had shorter urethral lengths. Furthermore, no increase in urethral length during pregnancy was registered among the stress incontinent women, whereas such an increase did occur in the continent women. In contrast to the continent women, the incontinent patients had a low urethral closure pressure at rest and this pressure did not appear to increase sufficiently to compensate for the progressive increase in bladder pressure during pregnancy. As a result the urethral closure pressure in the stress incontinent women, therefore, decreased more and more during stress situations as pregnancy progressed, resulting in an increased leakage of urine.
Continent women have better urethral neuromuscular function than those with stress incontinence
Mueller, Elizabeth; Brubaker, Linda
2012-01-01
Introduction and hypothesis The objective of this study is to describe urethral neuromuscular function using concentric needle electromyography (EMG) in stress incontinent (SUI) and asymptomatic women. Methods Following Institutional Review Board approval, we recruited SUI and asymptomatic women without urinary incontinence. Participants underwent quantitative urethral EMG and urodynamic testing. Results Sixty-seven women (37 SUI, 30 continent) with mean±SD age of 44±12 years participated. Nearly all EMG parameters showed significant differences between continent and SUI women consistent with better motor unit recruitment in continent women. Continent women had larger-amplitude, longer-duration motor unit action potentials (MUP) with increased turns and better MUP recruitment during bladder filling (P<.05). Increasing age was inversely correlated with nearly all MUP parameters (P<.05), suggesting MUP to be consistent with neuropathy. Conclusions We found significant differences in multiple MUP parameters in urethral sphincter between continent and stress incontinent women, suggesting continent women have better urethral innervation. We also found significant neuropathic MUP changes with advancing age, regardless of continence status. PMID:21979386
Repair of an incompetent urethral sphincter in a mare.
Schumacher, Jim; Brink, Palle
2011-01-01
To describe successful surgical treatment of urinary incontinence caused by a ruptured and/or transected urethral sphincter in a mare. Clinical report. A 7-year-old, Swedish Warmblood mare with urinary incontinence. The urethral sphincter, which had been damaged during removal of a cystic urolith, was repaired by apposing the ends of the disrupted urethralis muscle and tunica muscularis. The mare was no longer incontinent after repair of the defect by apposition of the ends of the urethralis muscle and tunica muscularis. Transection and/or rupture of the urethral sphincter of a mare may result in urinary incontinence. Apposition of the ends of the ruptured or transected urethralis muscle and tunica muscularis can correct urinary incontinence caused by this defect. © Copyright 2010 by The American College of Veterinary Surgeons.
Favorito, Luciano A; Conte, Paulo P; Sobrinho, Ulisses G; Martins, Rodrigo G; Accioly, Tomas
2017-11-17
Buccal mucosa grafts and fascio-cutaneous flaps are frequently used in long anterior urethral strictures (1). The inlay and onlay buccal mucosa grafts are easier to perform, do not need urethral mobilization and generally have good long-term results (2-4). In the present video, we present a case where we used a double buccal mucosa graft technique in a simultaneous penile and bulbar urethral stricture. A 54 year-old male patient was submitted to appendectomy where a urethral catheter was used for two days in May 2015. Three months after surgery, the patient complained of acute urinary retention and a supra-pubic tube was indicated. Urethrocystography was performed two weeks later and showed strictures in penile and bulbar urethra with 3.5 cm and 3 cm in length respectively. Urethroplasty was proposed for the surgical treatment in this case. We used a perineal approach with a ventral sagittal urethrotomy in both strictures. Penile urethra stricture measuring 3.5 cm in length was observed and a free graft from the buccal mucosa was harvested and placed into the longitudinal incision in the dorsal urethra and fixed with interrupted suture as dorsal inlay. Bulbar urethra stricture measuring 3 cm was observed and a free graft from the buccal mucosa was harvested and placed into the longitudinal incision in the ventral urethra and fixed with interrupted suture as ventral onlay. The ventral urethrotomy was closed over a 16Fr Foley catheter and the skin incision was then closed in layers. No intraoperative or postoperative complications occurred. The patient could achieve satisfactory voiding and no complication was seen during the six-month follow-up. Postoperative imaging demonstrated a widely patent urethra, and the mean peak flow was 12 mL/s. The BMG placement can be ventral, dorsal, lateral or combined dorsal and ventral BMG in the meeting of stricture but the first two are most common (5, 6). Ventral location provides the advantages of ease of exposure and good vascular supply by avoiding circumferential rotation of the urethra (7). Early success rates of dorsal and ventral onlay with BMG were 96 and 85%, respectively. However, long-term follow-up revealed essentially no difference in success rates (8-11). Anterior urethral stricture treatments are various, and comprehensive consideration should be given in selecting individualized treatment programs, which must be combined with the patient's stricture, length, complexity, and other factors. Traditionally, anastomotic procedures with transection and urethral excision are suggested for short bulbar strictures, while longer strictures are treated by patch graft urethroplasty preferably using the buccal mucosa as gold-standard material due to its histological characteristics. The current management for complex urethral strictures commonly uses open reconstruction with buccal mucosa urethroplasty. However, there are multiple situations whereby buccal mucosa is inadequate (pan-urethral stricture or prior buccal harvest) or inappropriate for utilization (heavy tobacco use or oral radiation). Multiple options exist for use as alternatives or adjuncts to buccal mucosa in complex urethral strictures (injectable antifibrotic agents, augmentation urethroplasty with skin flaps, lingual mucosa, colonic mucosa, and new developments in tissue engineering for urethral graft material). In the present case, our patient had two strictures and we chose to correct the first stricture with a dorsal graft and the bulbar stricture with a ventral graft because of our personal expertise. We can conclude that the double buccal mucosa graft is easier to perform and can be an option to repair multiple urethral strictures. Copyright® by the International Brazilian Journal of Urology.
High-Temperature Helical-Tube Solar Receiver
NASA Technical Reports Server (NTRS)
Robertson, C. S., Jr.; Mccreight, L.
1984-01-01
Solar-thermal receiver used with circular parabolic concentrator to supply about 58 kW thermal power to Brayton engine or industrial process. Solar radiation focused into open end of cylindrical ceramic thermal inertial sleeve 8 in. in diameter that reradiates energy to helical heatexchanger tube surrounding sleeve.
77 FR 39188 - Airworthiness Directives; the Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-02
... existing AD currently requires repetitive inspections to detect discrepancies of the wiring and surrounding... new sleeves, for certain airplanes; and repair or replacement of the wiring and sleeves with new parts... currently requires repetitive inspections to detect discrepancies of the wiring and surrounding Teflon...
Gandhi, Varun; Roberts, Philip J W; Stoesser, Thorsten; Wright, Harold; Kim, Jae-Hong
2011-07-01
Three-dimensional laser-induced fluorescence (3DLIF) was applied to visualize and quantitatively analyze mixing in a lab-scale UV reactor consisting of one lamp sleeve placed perpendicular to flow. The recirculation zone and the von Karman vortex shedding that commonly occur in flows around bluff bodies were successfully visualized. Multiple flow paths were analyzed by injecting the dye at various heights with respect to the lamp sleeve. A major difference in these pathways was the amount of dye that traveled close to the sleeve, i.e., a zone of higher residence time and higher UV exposure. Paths away from the center height had higher velocities and hence minimal influence by the presence of sleeve. Approach length was also characterized in order to increase the probability of microbes entering the region around the UV lamp. The 3DLIF technique developed in this study is expected to provide new insight on UV dose delivery useful for the design and optimization of UV reactors. Copyright © 2011 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cullen, W.K.; Keating, R.F.
1997-02-01
In the Spring and Fall of 1994, and the Spring of 1995, crack-like indications were found in the upper hybrid expansion joint (HEJ) region of Steam Generator (S/G) tubes which had been sleeved using Westinghouse HEJ sleeves. As a result of these findings, analytic and test evaluations were performed to assess the effect of the degradation on the structural, and leakage, integrity of the sleeve/tube joint relative to the requirements of the United States Nuclear Regulatory Commission`s (NRC) draft Regulatory Guide (RG) 1.121. The results of these evaluations demonstrated that tubes with implied or known crack-like circumferential parent tube indicationsmore » (PTIs) located 1.1 inches or farther below the bottom of the hardroll upper transition, have sufficient, and significant, integrity relative to the requirements of RG 1.121. Thus, the purpose of this report is to provide background information related to the justification of the modified tube repair boundary.« less
The effects of sleeve gastectomy on gastro-esophageal reflux and gastro-esophageal motility.
Hayat, Jamal O; Wan, Andrew
2014-05-01
Sleeve gastrectomy is an increasingly performed bariatric procedure associated with low morbidity and good short to medium term effects on weight loss and comorbid conditions. Studies assessing the prevalence of post-operative gastro-esophageal reflux disease (GERD), show sleeve gastrectomy may provoke de novo GERD symptoms or worsening of pre-existing GERD. Pathophysiological mechanisms of GERD after sleeve gastrectomy include a hypotensive lower esophageal sphincter, increased gastro-esophageal pressure gradient and intra-thoracic migration of the remnant stomach. A reduction in the compliance of the gastric remnant may provoke an increase in transient lower esophageal sphincter relaxations. Time-resolved MRI suggests relative gastric stasis in the proximal remnant and increased emptying from the antrum. A lack of standardisation of technique, along with heterogeneity of studies assessing GERD may explain the wide variability in reported results. Simultaneous and careful repair of an associated hiatus hernia may result in a reduction in the prevalence of post-operative GERD.
Apparatus for enhancing tissue repair in mammals
NASA Technical Reports Server (NTRS)
Goodwin, Thomas J. (Inventor); Parker, Clayton R. (Inventor)
2007-01-01
An apparatus is disclosed for enhancing tissue repair in mammals, with the apparatus comprising: a sleeve for encircling a portion of a mammalian body part, said sleeve comprising an electrically conductive coil capable of generating an electromagnetic field when an electrical current is applied thereto, means for supporting the sleeve on the mammalian body part; and means for supplying the electrically conductive coil with a square wave time varying electrical current sufficient to create a time varying electromagnetic force of from approximately 0.05 gauss to 0.05 gauss within the interior of the coil in order that when the sleeve is placed on a mammalian body part and the time varying electromagnetic force of from approximately 0.05 gauss to 0.05 gauss is generated on the mammalian body part for an extended period of time, tissue regeneration within the mammalian body part is increased to a rate in excess of the normal tissue regeneration rate that would occur without application of the time varying electromagnetic force.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habibi, M., E-mail: mortezahabibi@aut.ac.ir; Sharifi, R.; Amrollahi, R.
2013-12-15
The variation of the X-ray intensity has been investigated with the Pyrex and quartz insulators surface contamination in a 4-kJ plasma focus device with argon gas at 11.5-kV charging voltage. Elemental analysis (EDAX) showed that the Cu evaporated from the electrode material and was deposited on the sleeve surface improves the breakdown conditions. A small level of sleeve contamination by copper is found to be essential for good focusing action and high HXR intensity. The SEM imaging showed the grain-type structure of Cu formed on the surface and it changed the surface property. Resistance measurements of original and coated Pyrexmore » surface proved that the copper deposition on the sleeve surface will reduce its resistance as compared to the almost infinitely large resistance of the uncontaminated sleeve. As the contamination is surpassed to some critical level, the HXR intensity from the device is deteriorated.« less
Macura, Katarzyna Jadwiga; Thompson, Richard Eugene; Bluemke, David Alan; Genadry, Rene
2015-11-28
To define the magnetic resonance imaging (MRI) parameters differentiating urethral hypermobility (UH) and intrinsic sphincter deficiency (ISD) in women with stress urinary incontinence (SUI). The static and dynamic MR images of 21 patients with SUI were correlated to urodynamic (UD) findings and compared to those of 10 continent controls. For the assessment of the urethra and integrity of the urethral support structures, we applied the high-resolution endocavitary MRI, such as intraurethral MRI, endovaginal or endorectal MRI. For the functional imaging of the urethral support, we performed dynamic MRI with the pelvic phased array coil. We assessed the following MRI parameters in both the patient and the volunteer groups: (1) urethral angle; (2) bladder neck descent; (3) status of the periurethral ligaments, (4) vaginal shape; (5) urethral sphincter integrity, length and muscle thickness at mid urethra; (6) bladder neck funneling; (7) status of the puborectalis muscle; (8) pubo-vaginal distance. UDs parameters were assessed in the patient study group as follows: (1) urethral mobility angle on Q-tip test; (2) Valsalva leak point pressure (VLPP) measured at 250 cc bladder volume; and (3) maximum urethral closure pressure (MUCP). The UH type of SUI was defined with the Q-tip test angle over 30 degrees, and VLPP pressure over 60 cm H2O. The ISD incontinence was defined with MUCP pressure below 20 cm H2O, and VLPP pressure less or equal to 60 cm H2O. We considered the associations between the MRI and clinical data and UDs using a variety of statistical tools to include linear regression, multivariate logistic regression and receiver operating characteristic (ROC) analysis. All statistical analyses were performed using STATA version 9.0 (StataCorp LP, College Station, TX). In the incontinent group, 52% have history of vaginal delivery trauma as compared to none in control group (P < 0.001). There was no difference between the continent volunteers and incontinent patients in body habitus as assessed by the body mass index. Pubovaginal distance and periurethral ligament disruption are significantly associated with incontinence; periurethral ligament symmetricity reduces the odds of incontinence by 87%. Bladder neck funneling and length of the suprapubic urethral sphincter are significantly associated with the type of incontinence on UDs; funneling reduced the odds of pure UH by almost 95%; increasing suprapubic urethral sphincter length at rest is highly associated with UH. Both MRI variables result in a predictive model for UDs diagnosis (area under the ROC = 0.944). MRI may play an important role in assessing the contribution of hypermobility and sphincteric dysfunction to the SUI in women when considering treatment options.
Macura, Katarzyna Jadwiga; Thompson, Richard Eugene; Bluemke, David Alan; Genadry, Rene
2015-01-01
AIM: To define the magnetic resonance imaging (MRI) parameters differentiating urethral hypermobility (UH) and intrinsic sphincter deficiency (ISD) in women with stress urinary incontinence (SUI). METHODS: The static and dynamic MR images of 21 patients with SUI were correlated to urodynamic (UD) findings and compared to those of 10 continent controls. For the assessment of the urethra and integrity of the urethral support structures, we applied the high-resolution endocavitary MRI, such as intraurethral MRI, endovaginal or endorectal MRI. For the functional imaging of the urethral support, we performed dynamic MRI with the pelvic phased array coil. We assessed the following MRI parameters in both the patient and the volunteer groups: (1) urethral angle; (2) bladder neck descent; (3) status of the periurethral ligaments, (4) vaginal shape; (5) urethral sphincter integrity, length and muscle thickness at mid urethra; (6) bladder neck funneling; (7) status of the puborectalis muscle; (8) pubo-vaginal distance. UDs parameters were assessed in the patient study group as follows: (1) urethral mobility angle on Q-tip test; (2) Valsalva leak point pressure (VLPP) measured at 250 cc bladder volume; and (3) maximum urethral closure pressure (MUCP). The UH type of SUI was defined with the Q-tip test angle over 30 degrees, and VLPP pressure over 60 cm H2O. The ISD incontinence was defined with MUCP pressure below 20 cm H2O, and VLPP pressure less or equal to 60 cm H2O. We considered the associations between the MRI and clinical data and UDs using a variety of statistical tools to include linear regression, multivariate logistic regression and receiver operating characteristic (ROC) analysis. All statistical analyses were performed using STATA version 9.0 (StataCorp LP, College Station, TX). RESULTS: In the incontinent group, 52% have history of vaginal delivery trauma as compared to none in control group (P < 0.001). There was no difference between the continent volunteers and incontinent patients in body habitus as assessed by the body mass index. Pubovaginal distance and periurethral ligament disruption are significantly associated with incontinence; periurethral ligament symmetricity reduces the odds of incontinence by 87%. Bladder neck funneling and length of the suprapubic urethral sphincter are significantly associated with the type of incontinence on UDs; funneling reduced the odds of pure UH by almost 95%; increasing suprapubic urethral sphincter length at rest is highly associated with UH. Both MRI variables result in a predictive model for UDs diagnosis (area under the ROC = 0.944). CONCLUSION: MRI may play an important role in assessing the contribution of hypermobility and sphincteric dysfunction to the SUI in women when considering treatment options. PMID:26644825
Pawanindra, Lal; Vindal, Anubhav; Midha, Manoj; Nagpal, Prashant; Manchanda, Alpana; Chander, Jagdish
2015-10-01
Pre- and post-operative stomach volumes can be important determinants for effectiveness of laparoscopic sleeve gastrectomy (LSG) in causing weight loss. There is little existing data on the volumes of stomach preoperatively and that excised during LSG. This study was designed to evaluate the change in gastric volume after LSG using multi-detector CT and to correlate it with early post-operative weight loss. Twenty consecutive patients with BMI ≥ 40 kg/m(2) and medical comorbidities underwent LSG between October 2011 and October 2013 and were analysed prospectively. The pre-operative stomach volume was measured by MDCT done 1-3 days before the surgery. LSG was performed in the standard manner using a 36F bougie. The volume of excised stomach was measured by distending the specimen with saline. MDCT of the upper abdomen was repeated 3 months postoperatively to calculate the gastric sleeve volume. Weight loss and resolution of comorbidities were documented. The mean pre-operative weight of patients was 123.90 kg, and the mean pre-operative stomach volume on MDCT was 1,067 ml. The stomach volume on pre-operative MDCT correlated with pre-operative weight and BMI. The mean volume of the excised stomach was 859 ml when measured by distension of the specimen and 850 ml on MDCT. After 3 months post surgery, the mean volume of gastric sleeve on MDCT was 217 ml, and the mean weight of the patients was 101.22 kg. The volume of the excised stomach calculated by MDCT correlated with the weight loss achieved 3 months postoperatively. However, no correlation was seen between the gastric sleeve volume 3 months postoperatively and weight loss during this period. MDCT is a good method to measure gastric volume before and after LSG. Early post-operative weight loss (3 months) correlates well with the volume of the excised stomach but not with that of the gastric sleeve.
Hjorth, M H; Egund, N; Mechlenburg, I; Gelineck, J; Jakobsen, S S; Soballe, K; Stilling, M
2016-12-01
Little is known about pseudotumor frequency and risk factors for pseudotumor formation among different types of metal-on-metal (MoM) hip arthroplasties. A lower release of chromium and cobalt have been reported in MoM hip arthroplasties with a titanium sleeve compared to MoM designs without a titanium sleeve, but yet it is unknown whether a titanium sleeve reduces the pseudotumor frequency. We conducted a cross-sectional study to investigate: 1) pseudotumor frequency, 2) risk factors of pseudotumor formation 3) and correlations between pseudotumors, serum metal-ions, implant position, and clinical symptoms. We expected a lower pseudotumor frequency in MoM hip articulation with a titanium sleeve than reported in MoM hip articulation designs using chromium-cobalt sleeve. A consecutive series of 41 patients/49 hips (31 males), mean age 52 (28-68) years, participated in a 5.5±0.5 (4-6.5) year follow-up study of their M2a_Magnum hip articulation (Biomet Inc., Warsaw, Indiana, USA). Patients were evaluated with magnetic resonance imaging (MRI), measurements of serum metal-ions, plain radiographs, and clinical outcome measures of Harris Hip Score (HHS) and Oxford Hip Score (OHS). Eighteen of 47 hips (38%) had MRI-verified pseudotumors, all cystic, with a mean dimension of 10.6×25.6×41mm. Digital measurements on plain radiographs revealed a higher cup anteversion in patients with a pseudotumor of mean 28.4°±5.05° compared to mean 23.5°±6.5° in patients without a pseudotumor (P=0.009). Serum metal-ion concentrations, acetabular cup inclination and measures of HHS and OHS were similar between patients with and without a pseudotumor (P>0.46). At 5.5±0.5years after surgery, MRI-verified cystic pseudotumors were frequently observed in M2a_Magnum hip articulations despite the use of titanium sleeves. The pseudotumors were related to high cup anteversion angles but not related to high serum metal-ions or clinical symptoms. IV: cross-sectional study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Phosphoinositide-Driven Epithelial Proliferation in Prostatic Inflammation
2008-01-01
that IL-1β expression is localized to the urethral urothelium during development, and little or no expression is observed in the developing prostatic...ducts [Figure 3B]. By comparison, IL-1α expression is found both in the urethral urothelium and in the developing prostatic ducts [Figure 3A]. In...adult [C]. Hyperplasia was induced by E. coli for 5 days. In contrast, IL-1β [B,D] expression is localized to the urethral urothelium at P10 [B] and
Recurrent urethral obstruction secondary to idiopathic renal hematuria in a puppy.
Hawthorne, J C; deHaan, J J; Goring, R L; Randall, S R; Kennedy, F S; Stone, E; Zimmerman, K M; McAbee, S W
1998-01-01
A seven-month-old, neutered male Catahoula leopard dog cross was presented for recurrent urethral obstruction and intermittent hematuria. After exploratory laparotomy and ventral cystotomy, unilateral idiopathic renal hematuria was diagnosed based on gross observation of hematuria from the left ureteral catheter. The hematuria resolved after nephrectomy of the left kidney. The histopathological diagnosis was multifocal, acute congestion and intratubular hemorrhage. Although idiopathic renal hematuria has been described previously, this puppy was unique because the hematuria caused recurrent, complete urethral obstruction.
Bronchial and arterial sleeve resection for centrally-located lung cancers
D’Andrilli, Antonio; Venuta, Federico; Rendina, Erino Angelo
2016-01-01
The use of bronchial and arterial sleeve resections for the treatment of centrally-located lung cancers, when available, has become the option of choice in comparison with pneumonectomy (PN). Technical expertise, in particular in vascular reconstruction, and perioperative management improved over time allowing excellent short-term and long-term results. This is even truer if considering literature data from the main experiences published in the last years. These evidences have given to such lung sparing reconstructive procedures more and more acceptance among the surgical community. This article focuses on the main technical aspects and literature data regarding bronchovascular sleeve resections. PMID:27942409
NASA Technical Reports Server (NTRS)
Wang, D. S.; Warren, A. D. (Inventor)
1980-01-01
A method for installing fragile, high temperature insulation batting in an elongated cavity or in a resilient wire sleeve to form a resilient seal. The batting is preformed to rough dimensions and wrapped in a plastic film, the film being of a material which is fugitive at a high temperature. The film is heat sealed and trimmed to form a snugly fit skin which overlaps at least at one end to permit attachment of a pull cord. The film absorbs the tensile force of pulling the film enclosed batting through the cavity or wire mesh sleeve and is subsequently driven off by high temperature baking, leaving only the insulation in the cavity or wire mesh sleeve.
Study on coming out of the shaft from ceramic sleeve in terms of the residual displacement
NASA Astrophysics Data System (ADS)
Zhang, G. W.; Noda, N.-A.; Sano, Y.; Sakai, H.
2018-06-01
Ceramic roller can be used in the heating furnace conveniently because of its high temperature resistance. However, the coming out of the shaft may often happen from the ceramic sleeve under repeated load. In this paper, a two-dimensional shrink fitted structure is considered by replacing the shaft with the inner plate and by replacing the sleeve with the outer plate. Based on the model with stopper, the FEM simulation is performed under alternate loading with certain intervals newly added. The analysis results show that the coming out failure can be explained from the residual displacement accumulation during these intervals.
2013-01-01
Background Vesico-urethral function may be evaluated in humans and dogs by conventional urodynamic testing (cystometry and urethral pressure profilometry) or by electromyography. These techniques are performed under general anaesthesia in dogs. However, anaesthesia can depress bladder and urethral pressures and inhibit the micturition reflex. The primary objective of this pilot study was to evaluate the use of telemetry for urodynamic investigation in dogs. We also aimed to determine the applicability of telemetry to toxicologic studies by assessing the repeatability of telemetric recordings. Results Conventional diuresis cystometry was performed in six continent adult female Beagle dogs prior to surgical implantation of telemetric and electromyographic devices. In the first phase of the telemetric study, continuous recordings were performed over 8 days and nights. Abdominal, intravesical and detrusor threshold pressures (Pdet th), voided volume (Vv), urethral smooth muscle electrical activity and involuntary detrusor contractions (IDC) were measured during the bladder filling phase and during micturition episodes. Vv recorded during telemetry was significantly lower than bladder volume obtained by diuresis cystometry. Repeatability of telemetric measurements was greater for observations recorded at night. IDC frequency and Pdet th were both lower and Vv was higher at night compared to values recorded during daytime. In the second phase of the telemetric study, phenylpropanolamine, oestriol, bethanechol, oxybutynin or duloxetine were administered orally for 15 days. For each drug, continuous recordings were performed overnight for 12 hours on days 0, 1, 8 and 15. Electromyographic urethral activity was significantly increased 8 days after oestriol or duloxetine administration. No significant changes in bladder function were observed at any time point. Conclusions In dogs, the high repeatability of nocturnal telemetric recordings indicates that this technique could provide more informative results for urologic research. Urethral smooth muscle electrical activity appears to be modified by administration of drugs with urethral tropism. In this pilot telemetric study, bladder function was not affected by oral administration of urological drugs at their recommended clinical dosages. Experimental studies, (pharmacokinetic and pharmacodynamic) and clinical studies are warranted to further define the effects of these drugs on vesico-urethral function in dogs. PMID:24099564
Characterization of bulbospongiosus muscle reflexes activated by urethral distension in male rats.
Tanahashi, Masayuki; Karicheti, Venkateswarlu; Thor, Karl B; Marson, Lesley
2012-10-01
The urethrogenital reflex (UGR) is used as a surrogate model of the autonomic and somatic nerve and muscle activity that accompanies ejaculation. The UGR is evoked by distension of the urethra and activation of penile afferents. The current study compares two methods of elevating urethral intraluminal pressure in spinalized, anesthetized male Sprague-Dawley rats (n = 60). The first method, penile extension UGR, involves extracting the penis from the foreskin, so that urethral pressure rises due to a natural anatomical flexure in the penis. The second method, penile clamping UGR, involves penile extension UGR with the addition of clamping of the glans penis. Groups of animals were prepared that either received no additional treatment, surgical shams, or received bilateral nerve cuts (4 nerve cut groups): either the pudendal sensory nerve branch (SbPN), the pelvic nerves, the hypogastric nerves, or all three nerves. Penile clamping UGR was characterized by multiple bursts, monitored by electromyography (EMG) of the bulbospongiosus muscle (BSM) accompanied by elevations in urethral pressure. The penile clamping UGR activity declined across multiple trials and eventually resulted in only a single BSM burst, indicating desensitization. In contrast, the penile extension UGR, without penile clamping, evoked only a single BSM EMG burst that showed no desensitization. Thus, the UGR is composed of two BSM patterns: an initial single burst, termed urethrobulbospongiosus (UBS) reflex and a subsequent multiple bursting pattern (termed ejaculation-like response, ELR) that was only induced with penile clamping urethral occlusion. Transection of the SbPN eliminated the ELR in the penile clamping model, but the single UBS reflex remained in both the clamping and extension models. Pelvic nerve (PelN) transection increased the threshold for inducing BSM activation with both methods of occlusion but actually unmasked an ELR in the penile extension method. Hypogastric nerve (HgN) cuts did not significantly alter any parameter. Transection of all three nerves eliminated BSM activation completely. In conclusion, penile clamping occlusion recruits penile and urethral primary afferent fibers that are necessary for an ELR. Urethral distension without significant penile afferent activation recruits urethral primary afferent fibers carried in either the pelvic or pudendal nerve that are necessary for the single-burst UBS reflex.
77 FR 65501 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-29
... done. (g) Retained Replacement of Wiring, Installation of Sleeving, and Associated Actions This... requires replacing wiring for the fuel boost pumps and override pumps with new wiring, installing Teflon sleeving on the wiring, and doing associated actions; and doing repetitive inspections to detect damage of...
78 FR 10499 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-14
... done. (g) Retained Replacement of Wiring, Installation of Sleeving, and Associated Actions This... replacing wiring for the fuel boost pumps and override pumps with new wiring, installing Teflon sleeving on the wiring, and doing associated actions; and doing repetitive inspections to detect damage of the...
Effect of brace design on patients with ACL-ruptures.
Strutzenberger, G; Braig, M; Sell, S; Boes, K; Schwameder, H
2012-11-01
Different designs of functional knee braces for ACL-injury rehabilitation exist. In addition to the mechanical stabilization provided by rigid shell braces, sleeve braces also address proprioceptive mechanisms, but little is known if this leads to benefits for ACL-deficient subjects. Therefore the aim of this study was to investigate the effect of 2 different functional brace designs (shell and sleeve brace) on functional achievements in ACL-deficient patients. 28 subjects with ACL-ruptured knees performed tests for knee joint laxity, joint position sense, static and dynamic balance and isometric and dynamic lower limb extension strength in non-braced, sleeve braced and shell braced condition. The results showed a significant decrease in knee joint laxity for sleeve (33%; p<0.001) and rigid shell bracing (14%, p=0.039). The sleeve brace revealed a significant increase in dynamic balance after perturbation (20%; p=0.024) and a significant increase in dynamic lower limb peak rate of force development (17%; p=0.015) compared to the non-braced condition. The effects might be caused by the flexible area of support and the incorporated mechanisms to address proprioceptive aspects. Braces might not be needed in simple daily life tasks, but could provide beneficial support in more dynamic settings when patients return to sporting activities after an ACL-injury. © Georg Thieme Verlag KG Stuttgart · New York.
Avidov, R; Saadi, I; Krassnovsky, A; Hanan, A; Medina, Sh; Raviv, M; Chen, Y; Laor, Y
2017-09-01
Composting in polyethylene sleeves with forced aeration may minimize odor emissions, vectors attraction and leachates associated with open windrows. A disadvantage of this technology is the lack of mixing during composting, potentially leading to non-uniform products. In two pilot experiments using biosolids and green waste (1:1; v:v), thermophilic conditions (>45°C) were maintained for two months, with successful control of oxygen levels and sufficient moisture. Emitted odors declined from 1.5-3.8×10 5 to 5.9×10 3 -2.3×10 4 odor units m -3 -air in the first 3weeks of the process, emphasizing the need of odor control primarily during this period. Therefore, composting might be managed in two phases: (i) a closed sleeve for 6-8weeks during which the odor is treated; (ii) an open pile (odor control is not necessary). Reduction of salmonella, E. coli and coliforms was effective initially, meeting the standards of "Class A" biosolids; however, total and fecal coliforms density increased after opening the second sleeve and exceeded the standard of 1000 most probable number (MPN) per g dry matter. Compost maturity was achieved in the open piles following the two sleeves and the final compost was non-phytotoxic and beneficial as a soil additive. Copyright © 2017 Elsevier Ltd. All rights reserved.
Self-actuating and locking control for nuclear reactor
Chung, Dong K.
1982-01-01
A self-actuating, self-locking flow cutoff valve particularly suited for use in a nuclear reactor of the type which utilizes a plurality of fluid support neutron absorber elements to provide for the safe shutdown of the reactor. The valve comprises a substantially vertical elongated housing and an aperture plate located in the housing for the flow of fluid therethrough, a substantially vertical elongated nozzle member located in the housing and affixed to the housing with an opening in the bottom for receiving fluid and apertures adjacent a top end for discharging fluid. The nozzle further includes two sealing means, one located above and the other below the apertures. Also located in the housing and having walls surrounding the nozzle is a flow cutoff sleeve having a fluid opening adjacent an upper end of the sleeve, the sleeve being moveable between an upper open position wherein the nozzle apertures are substantially unobstructed and a closed position wherein the sleeve and nozzle sealing surfaces are mated such that the flow of fluid through the apertures is obstructed. It is a particular feature of the present invention that the valve further includes a means for utilizing any increase in fluid pressure to maintain the cutoff sleeve in a closed position. It is another feature of the invention that there is provided a means for automatically closing the valve whenever the flow of fluid drops below a predetermined level.
Desart, Kenneth; Rossidis, Georgios; Michel, Michael; Lux, Tamara; Ben-David, Kfir
2015-10-01
Laparoscopic sleeve gastrectomy (LSG) has gained significant popularity in the USA, and consequently resulted in patients experiencing new-onset gastroesophageal reflux disease (GERD) following this bariatric procedure. Patients with GERD refractory to medical therapy present a more challenging situation limiting the surgical options to further treat the de novo GERD symptoms since the gastric fundus to perform a fundoplication is no longer an option. The aim of this study is to determine if the LINX® magnetic sphincter augmentation system is a safe and effective option for patients with new gastroesophageal reflux disease following laparoscopic sleeve gastrectomy. This study was conducted at the University Medical Center. This is a retrospective review of seven consecutive patients who had a laparoscopic LINX® magnetic sphincter device placement for patients with refractory gastroesophageal reflux disease after laparoscopic sleeve gastrectomy between July 2014 and April 2015. All patients were noted to have self-reported greatly improved gastroesophageal reflux symptoms 2-4 weeks after their procedure. They were all noted to have statistically significant improved severity and frequency of their reflux, regurgitation, epigastric pain, sensation of fullness, dysphagia, and cough symptoms in their postoperative GERD symptoms compared with their preoperative evaluation. This is the first reported pilot case series, illustrating that the LINX® device is a safe and effective option in patients with de novo refractory gastroesophageal reflux disease after a laparoscopic sleeve gastrectomy despite appropriate weight loss.
Endoscopic sleeve gastroplasty (the Apollo method): a new approach to obesity management.
López-Nava Breviere, Gontrand; Bautista-Castaño, Inmaculada; Fernández-Corbelle, Juan Pedro; Trell, Marta
2016-04-01
Many obese patients cannot lose weight or reject conventional obesity management. Endoscopic sleeve gastroplasty (the Apollo method) is a pioneering coadjuvant, interventionist technique for the integral management of obesity. The goals of this study were to report safety and efficacy results obtained at 6 months in patients undergoing endoscopic sleeve gastroplasty. A prospective study was performed in 55 patients (13 males, 42 females) who were subjected to the Apollo technique; mean age was 43.5 years (range 25-60) and mean BMI was 37.7 kg/m2 (range 30-48). All received multidisciplinary follow-up for weight loss. Weight changes and presence of complications were assessed. Through the endoscope a triangular pattern suture is performed consisting of approximately 3-6 transmural (mucosa to serosa) stitches, using a cinch device to bring them nearer and form a plication. A total of 6-8 plications are used to provide a tubular or sleeve-shaped restriction to the gastric cavity. No major complications developed and patients were discharged at 24 hours following the procedure. Endoscopic and radiographic follow-up at 6 months post-procedure showed a well preserved tubular form to the stomach. After 6 months patients had lost 18.9 kg and 55.3% of excess weight. Endoscopic sleeve gastroplasty, together with dietary and psycho-behavioral changes, is a safe, effective technique in the coadjuvant management of obese patients.
Delayed vaginal and urethral mesh exposure: 10 years after TVT surgery.
Khanuengkitkong, Siwatchaya; Lo, Tsia-Shu; Dass, Anil Krishna
2013-03-01
Delayed mesh exposure after tension-free vaginal tape (TVT) procedure is rare. We report a case of mesh exposure into the vagina and urethra that developed 10 years after TVT surgery. A 58-year-old postmenopausal woman presented with mixed urinary incontinence. She was investigated, and her stress urinary incontinence was cured with a TVT procedure 10 years ago. She was then scheduled follow-up annually. Two years postsurgery, a granulation tissue was observed and excised at the vaginal incision site. Vaginal examination 10 years postsurgery showed vaginal mesh erosion 0.5 cm from urethral meatus. Cystoscopy revealed concomitant urethral erosion at the posterior urethral wall. Mesh excision was performed, and urethra and vagina were repaired in layers. Postoperative recovery was uneventful. This finding shows that, although rare, complications can occur even after 10 years of TVT surgery.
Dogra, P N; Nabi, G
2002-01-01
To assess the feasibility, problems and results of Nd-YAG laser core through urethrotomy in the management of failed urethroplasty for posttraumatic bulbomembranous urethral strictures. 61 patients with obliterative posttraumatic urethral strictures were treated by Nd-YAG laser core through urethrotomy between May 1997 to April 2000. Of these, 5 patients had failed end-to-end urethroplasty done as an initial procedure at various periods of time. The procedure was performed as day care and patients were discharged within 6 h of procedure. At 24-30 months of follow-up, all patients are voiding well and are continent. Auxiliary procedures were required in 2 cases. Nd-YAG laser core through urethrotomy is a feasible day care option for patients of obliterative urethral strictures following failed initial urethroplasty with successful outcome. Copyright 2002 S. Karger AG, Basel
Con: bulbomembranous anastomotic urethroplasty for pelvic fracture urethral injuries
Tausch, Timothy J.
2015-01-01
Current literature remains controversial regarding whether to treat patients sustaining pelvic fracture urethral injuries (PFUIs) with primary endoscopic realignment (PER) versus suprapubic tube (SPT) placement alone with elective bulbomembranous anastomotic urethroplasty (BMAU). Success rates for PER following PFUI are wide-ranging, depending on various authors’ definitions of what defines a successful outcome. At our institution, for SPT/BMAU patients, the mean time to definitive resolution of stenosis was dramatically shorter compared to PER cases. The vast majority of PER patients required multiple endoscopic urethral interventions and/or experienced various other adverse events which were rarely noted among the SPT/BMAU group. While PER does occasionally result in urethral patency without the need for further intervention, the risk of delay in definitive treatment and potential for adverse events has led to a preference for SPT and elective BMAU at our institution. PMID:26816814
Injuries to the urethra and urinary bladder associated with fractures of the pelvis.
Morehouse, D D
1988-03-01
The posterior urethra or urinary bladder may be injured in patients who sustain fractures of the bony pelvis. It is important to assess the urethra radiologically by retrograde urethrography before introducing a urethral catheter to avoid missing a urethral injury or causing further damage. The author's approach to the immediate management of urethral injury is suprapubic cystostomy. The urethra may be repaired later after other injuries have healed. With this approach the incidence of permanent impotence and incontinence will be low and the stricture cure rate high. If the urethra has not been injured, a catheter is introduced and cystography performed to rule out bladder injuries. If the bladder is ruptured, the area is explored, the perivesical space drained and urinary drainage is provided by either a suprapubic cystostomy or a urethral catheter.
Urethral Caruncle Presented as Premature Menarche in a 4-Year-Old Girl.
Gamage, Manori; Beneragama, D
2018-01-01
Urethral caruncle (UC) is a benign fleshy outgrowth at the urethral meatus. It was first described by Samuel Sharp in 1750 and occurs mainly at the posterior lip of the urethra, and the exact aetiology is still uncertain. More often it was seen in the postmenopausal women, and only few cases are reported in young girls. Patients may be asymptomatic and could find this as an incidental finding or they may present with symptoms such as dysuria, bleeding per vagina, haematuria, a mass protruding through vagina, and acute retention of urine. Here, we report the case history of a 4-year-old girl presented with vaginal bleeding which was taken as she has attended menarche and found to have urethral caruncle which was the cause for bleeding. Histology confirmed the diagnosis, and girl was completely cured following surgical excision.
Urethral catheter insertion forces: a comparison of experience and training.
Canales, Benjamin K; Weiland, Derek; Reardon, Scott; Monga, Manoj
2009-01-01
This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6) had the lowest average insertion force for any group at 6.8 +/- 2.0 Newtons (N). Medical students (n = 10) had the least amount of experience (1 +/- 0 years) and the highest average insertion force range of 10.1 +/- 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 +/- 1.8 N) compared to all groups (p < 0.01). We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.
Hoag, Nathan; Gani, Johan; Chee, Justin
2016-07-01
To present a novel modification of surgical technique to treat female urethral stricture (FUS) by a vaginal-sparing ventral buccal mucosal urethroplasty. Recurrent FUS represents an uncommon, though difficult clinical scenario to manage definitively. A variety of surgical techniques have been described to date, yet a lack of consensus on the optimal procedure persists. We present a 51-year-old female with urethral stricture involving the entire urethra. Suspected etiology was iatrogenic from cystoscopy 17 years prior. Since then, the patient had undergone at least 25 formal urethral dilations and periods of self-dilation. In lithotomy position, the urethra was dilated to accommodate forceps, and ventral urethrotomy carried out sharply, exposing a bed of periurethral tissue. Buccal mucosa was harvested, and a ventral inlay technique facilitated by a nasal speculum, was used to place the graft from the proximal urethra/bladder neck to urethral meatus without a vaginal incision. Graft was sutured into place, and urethral Foley catheter inserted. The vaginal-sparing ventral buccal mucosal graft urethroplasty was deemed successful as of last follow-up. Flexible cystoscopy demonstrated patency of the repair at 6 months. At 10 months of follow-up, the patient was voiding well, with no urinary incontinence. No further interventions have been required. This case describes a novel modification of surgical technique for performing buccal mucosal urethroplasty for FUS. By avoiding incision of the vaginal mucosa, benefits may include reduced: morbidity, urinary incontinence, and wound complications including urethro-vaginal fistula.
Mouraviev, Vladimir B; Coburn, Michael; Santucci, Richard A
2005-03-01
Urological treatment of the patient with severe mechanical trauma and urethral disruption remains controversial. Debate continues regarding the advisability of early realignment vs delayed open urethroplasty. We analyzed our experience with 96 patients to determine the long-term results of the 2 approaches. We retrospectively reviewed the records of 191 men with posterior urethral disruption after severe blunt pelvic injury between 1984 and 2001, of whom 96 survived. Data on 57 patients who underwent early realignment were compared to those on 39 treated with delayed urethroplasty with an average 8.8-year followup (range 1 to 22). All patients were evaluated postoperatively for incontinence, impotence and urethral strictures. The majority of patients had severe concomitant organ injuries (78%) and severe pelvic fractures (76%). The overall mortality rate was 51%. Diagnosis of urethral rupture was based on clinical findings and retrograde urethrography. Strictures developed in 49% of the early realignment group and in 100% of the suprapubic tube group. Impotence (33.6%) and incontinence (17.7%) were less frequent in the early realignment group than in the delayed reconstruction group (42.1% and 24.9%, respectively). Patients with delayed reconstruction underwent an average of 3.1 procedures compared with an average of 1.6 in the early realignment group. Early realignment may provide better outcomes than delayed open urethroplasty after posterior urethral disruption. Increased complications are not seen and, although it can be inconvenient in the massively injured patient, it appears to be a worthwhile maneuver.
Early endoscopic realignment of post-traumatic posterior urethral disruption.
Moudouni, S M; Patard, J J; Manunta, A; Guiraud, P; Lobel, B; Guillé, F
2001-04-01
The management of complete or partial urethral disruption is controversial, and much debate continues regarding immediate versus delayed definitive therapy. We further analyze our experience and long-term results using early endoscopic realignment. Between April 1987 and January 1999, 29 men with posterior urethral disruption (23 complete and 6 partial) underwent primary urethral realignment 0 to 8 days after injury. Pelvic fractures were present in 23 patients. In all patients, the actual operating time for realignment was 75 minutes or less. All patients were evaluated postoperatively for incontinence, impotence, and strictures. After a mean follow-up of 68 months (range 18 to 155), all patients were continent. Four patients (13.7%) required conversion to an open perineal urethroplasty. At the last follow-up visit, 25 (86%) of the 29 patients were potent and 4 achieved adequate erections for intercourse using intracorporeal injections (prostaglandin E(1)). Twelve patients (41%) developed short secondary strictures and were successfully treated with internal urethrotomy. The mean follow-up of these 12 patients was 83 months (range 34 to 120). Urinary flow rate measurement at the last follow-up visit revealed satisfactory voiding parameters in all patients. Primary endoscopic realignment offers an effective method for treating traumatic urethral injuries. Our long-term follow-up provides additional support for the use of this technique by demonstrating that urethral continuity can be established without an increased incidence of impotence, stricture formation, or incontinence. In case of failure, endoscopic realignment does not compromise the result of secondary urethroplasty.
Tewari, Ashutosh; Rao, Sandhya; Mandhani, Anil
2008-09-01
To study the feasibility of avoiding a urethral catheter after robotic radical prostatectomy by using suprapubic diversion with a urethral splint, as urethral catheterization is often a source of major discomfort and pain to the patient, and can cause more concern to the patient than the procedure; we present the outcomes of a pilot study. This pilot study involved 30 patients; in group 1 (the study group of 10 patients) we used a custom-made suprapubic catheter which provided a small anastomotic splint, multiple holes for drainage and the ability to retract the splint to give a voiding trial before removing the drainage device. Group 2 was a control group of 20 patients who had standard urethral catheterization with an 18 F Silastic Foley catheter. Demographic, intraoperative and outcome data were measured and analysed. Urethral symptoms were recorded using a specially developed questionnaire. The two groups were comparable in terms of age, serum prostate specific antigen level, body mass index, Gleason scores, tumour stage, operative duration, amount of bleeding, console times, anastomotic leakage and postoperative retention rates. The study group had significantly less penile shaft or tip pain and discomfort during walking or sleeping. No patient in either group had haematuria or clot retention requiring irrigation. Urethral catheter-less robotic radical prostatectomy is feasible. The advantages are decreased penile shaft and tip pain, and decreased patient discomfort and an earlier return of continence.
75 FR 12667 - Airworthiness Directives; Learjet Inc. Model 45 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-17
... certain Model 45 airplanes. This AD requires a general visual inspection for cracked and missing ballscrew... sleeve or flap actuator for cracks, and replacement or modification of the flap actuator if necessary. This AD results from reports of cracked and missing ballscrew assembly sleeves of the flap actuators...
Section Work--Sleeves; Apparel Manufacturing: 9377.08.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
This course involves practice in a sleeve-making techniques. Prior to entry in this course the vocational student will have completed "Section Work--Pocket Setting." Upon completion of the course the student will be able to understand the underlying principles of sewing individual sections of garments using factory techniques comparable…
75 FR 77790 - Airworthiness Directives; The Boeing Company Model 767 Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-14
... repetitive inspections to detect discrepancies of the wiring and surrounding Teflon sleeves of the fuel tank... airplanes; and repair or replacement of the wiring and sleeves with new parts, as necessary. This proposed...).) That AD requires repetitive inspections to detect discrepancies of the wiring and surrounding Teflon...
Moving body velocity arresting line. [stainless steel cables with energy absorbing sleeves
NASA Technical Reports Server (NTRS)
Hull, R. A. (Inventor)
1981-01-01
The arresting of a moving body is improved through the use of steel cables that elongate to absorb the kinetic energy of the body. A sleeve surrounds the cables, protecting them from chafing and providing a failsafe energy absorbing system should the cables fail.
Wong, Susan S W; Narahari, Radhakrishna; O'Riordan, Anna; Pickard, Robert
2010-04-14
Strictures of the urethra are the commonest cause of obstructed micturition in younger men and frequently recur after initial treatment. Standard treatment comprises internal widening of the strictured area by simple dilatation or by telescope-guided internal cutting (optical urethrotomy), but these interventions are associated with a high failure rate requiring repeated treatment. The alternative option of open urethroplasty whereby the urethral lumen is permanently widened by removal or grafting of the strictured segment is less likely to fail but requires greater expertise. Improved choice of graft material and shortened hospital stay suggest urethroplasty may be under used. The extent and quality of evidence guiding treatment choice for this condition is uncertain. To determine which is the best surgical treatment for male urethral stricture disease taking into account relative efficacy, adverse event rates and cost-effectiveness. We searched the Cochrane Incontinence Group Specialised Register (searched 26 March 2009), CENTRAL (2009, Issue 1), MEDLINE (January 1950 to March 2009), EMBASE (January 1980 to March 2009), OpenSIGLE (searched 26 March 2009), clinical trials registries and reference lists of relevant articles. We included publications reporting data from randomised or quasi-randomised controlled trials comparing the effectiveness of dilatation, urethrotomy and urethroplasty in the treatment of adult men with urethral stricture disease. Two authors evaluated trials for appropriateness for inclusion and methodological quality. Data extraction was performed using predetermined criteria. Analyses were carried out using the Cochrane Review Manager software; RevMan 5. Two randomised trials were identified. One trial compared the outcome of surgical urethral dilatation and optical urethrotomy in 210 adult men with urethral stricture disease. No significant difference was found in the proportion of men being stricture free at three years or in the median time to recurrence. The second trial compared the outcome of urethrotomy and urethroplasty in 50 men with traumatic stricture of the posterior urethra following pelvic fracture injury. After two years 16 of 25 (64%) men initially treated by urethrotomy required continued self-dilatation or further surgery for stricture recurrence compared to 6 of 25 (24%) men treated by primary urethroplasty. There was insufficient data to perform meta-analysis or to reliably determine effect size. There were insufficient data to determine which intervention is best for urethral stricture disease in terms of balancing efficacy, adverse effects and costs. Well designed, adequately powered multi-centre trials are needed to answer relevant clinical questions regarding treatment of men with urethral strictures.
Gite, Venkat A; Nikose, Jayant V; Bote, Sachin M; Patil, Saurabh R
2017-07-02
Many techniques have been described to correct anterior hypospadias with variable results. Anterior urethral advancement as one stage technique was first described by Ti Chang Shing in 1984. It was also used for the repair of strictures and urethrocutaneous fistulae involving distal urethra. We report our experience of using this technique with some modification for the repair of anterior hypospadias. In the period between 2013-2015, 20 cases with anterior hypospadias including 2 cases of glanular, 3 cases of coronal, 12 cases of subcoronal and 3 cases of distal penile hypospadias were treated with anterior urethral advancement technique. Patients' age groups ranged from 18 months to 10 years. Postoperatively, patients were passing urine from tip of neomeatus with satisfactory stream during follow up period of 6 months to 2 years. There were no major complications in any of our patients except in one patient who developed meatal stenosis which was treated by periodic dilatation. Three fold urethral mobilization was sufficient in all cases. Anterior urethral advancement technique is a single-stage procedure with good cosmetic results and least complications for anterior hypospadias repair in properly selected cases.
Computational Modeling and Simulation of Genital Tubercle ...
Hypospadias is a developmental defect of urethral tube closure that has a complex etiology. Here, we describe a multicellular agent-based model of genital tubercle development that simulates urethrogenesis from the urethral plate stage to urethral tube closure in differentiating male embryos. The model, constructed in CompuCell3D, implemented spatially dynamic signals from SHH, FGF10, and androgen signaling pathways. These signals modulated stochastic cell behaviors, such as differential adhesion, cell motility, proliferation, and apoptosis. Urethral tube closure was an emergent property of the model that was quantitatively dependent on SHH and FGF10 induced effects on mesenchymal proliferation and endodermal apoptosis, ultimately linked to androgen signaling. In the absence of androgenization, simulated genital tubercle development defaulted to the female condition. Intermediate phenotypes associated with partial androgen deficiency resulted in incomplete closure. Using this computer model, complex relationships between urethral tube closure defects and disruption of underlying signaling pathways could be probed theoretically in multiplex disturbance scenarios and modeled into probabilistic predictions for individual risk for hypospadias and potentially other developmental defects of the male genital tubercle. We identify the minimal molecular network that determines the outcome of male genital tubercle development in mice.
Pathologic Outcomes following Urethral Diverticulectomy in Women
Laudano, Melissa A.; Jamzadeh, Asha E.; Lee, Richard K.; Robinson, Brian D.; Tyagi, Renuka; Kaplan, Steven A.; Te, Alexis E.
2014-01-01
Purpose. Although most urethral diverticula in women are benign, there is a subset of patients who develop malignant changes. Limited studies report the pathologic findings associated with this relatively rare entity. We describe the clinicopathologic findings of women who underwent urethral diverticulectomy. Methods. A consecutive series of 29 women who underwent surgical resection of a urethral diverticulum were identified between 1992 and 2013. Clinical and radiographic data was collected by retrospective review of patient medical records. All pathological slides were rereviewed by a single urologic pathologist. Results. Of the 14 women with clinical data, 9 (64%) presented with urgency, 7 (50%) with urinary frequency, 3 (21%) with urinary incontinence, and 3 (21%) with dysuria. Mean diverticular size was 2.3 (±1.4) cm. Although one patient (3%) had invasive adenocarcinoma on final pathology, the remaining 28 cases (97%) demonstrated benign features. The most common findings were inflammation (55%) and nephrogenic adenoma (21%). Conclusions. Although most urethral diverticula in women are benign, there is a subset of patients who develop malignancy in association with the diverticulum. In this series, 97% of cases had a benign histology. These findings are important when counseling patients regarding treatment options. PMID:24860605
Pathologic Outcomes following Urethral Diverticulectomy in Women.
Laudano, Melissa A; Jamzadeh, Asha E; Dunphy, Claire; Lee, Richard K; Robinson, Brian D; Tyagi, Renuka; Kaplan, Steven A; Te, Alexis E; Chughtai, Bilal
2014-01-01
Purpose. Although most urethral diverticula in women are benign, there is a subset of patients who develop malignant changes. Limited studies report the pathologic findings associated with this relatively rare entity. We describe the clinicopathologic findings of women who underwent urethral diverticulectomy. Methods. A consecutive series of 29 women who underwent surgical resection of a urethral diverticulum were identified between 1992 and 2013. Clinical and radiographic data was collected by retrospective review of patient medical records. All pathological slides were rereviewed by a single urologic pathologist. Results. Of the 14 women with clinical data, 9 (64%) presented with urgency, 7 (50%) with urinary frequency, 3 (21%) with urinary incontinence, and 3 (21%) with dysuria. Mean diverticular size was 2.3 (±1.4) cm. Although one patient (3%) had invasive adenocarcinoma on final pathology, the remaining 28 cases (97%) demonstrated benign features. The most common findings were inflammation (55%) and nephrogenic adenoma (21%). Conclusions. Although most urethral diverticula in women are benign, there is a subset of patients who develop malignancy in association with the diverticulum. In this series, 97% of cases had a benign histology. These findings are important when counseling patients regarding treatment options.
Computational Modeling and Simulation of Genital Tubercle Development
Hypospadias is a developmental defect of urethral tube closure that has a complex etiology involving genetic and environmental factors, including anti-androgenic and estrogenic disrupting chemicals; however, little is known about the morphoregulatory consequences of androgen/estrogen balance during genital tubercle (GT) development. Computer models that predictively model sexual dimorphism of the GT may provide a useful resource to translate chemical-target bipartite networks and their developmental consequences across the human-relevant chemical universe. Here, we describe a multicellular agent-based model of genital tubercle (GT) development that simulates urethrogenesis from the sexually-indifferent urethral plate stage to urethral tube closure. The prototype model, constructed in CompuCell3D, recapitulates key aspects of GT morphogenesis controlled by SHH, FGF10, and androgen pathways through modulation of stochastic cell behaviors, including differential adhesion, motility, proliferation, and apoptosis. Proper urethral tube closure in the model was shown to depend quantitatively on SHH- and FGF10-induced effects on mesenchymal proliferation and epithelial apoptosis??both ultimately linked to androgen signaling. In the absence of androgen, GT development was feminized and with partial androgen deficiency, the model resolved with incomplete urethral tube closure, thereby providing an in silico platform for probabilistic prediction of hypospadias risk across c
Dorsal buccal mucosa graft urethroplasty for female urethral strictures.
Migliari, Roberto; Leone, Pierluigi; Berdondini, Elisa; De Angelis, M; Barbagli, Guido; Palminteri, Enzo
2006-10-01
We describe the feasibility and complications of dorsal buccal mucosa graft urethroplasty in female patients with urethral stenosis. From April 2005 to July 2005, 3 women 45 to 65 years old (average age 53.7) with urethral stricture disease underwent urethral reconstruction using a dorsal buccal mucosa graft. Stricture etiology was unknown in 1 patient, ischemic in 1 and iatrogenic in 1. Buccal mucosa graft length was 5 to 6 cm and width was 2 to 3 cm. The urethra was freed dorsally until the bladder neck and then opened on the roof. The buccal mucosa patch was sutured to the margins of the opened urethra and the new roof of the augmented urethra was quilted to the clitoris corpora. In all cases voiding urethrogram after catheter removal showed a good urethral shape with absent urinary leakage. No urinary incontinence was evident postoperatively. On urodynamic investigation all patients showed an unobstructed Blaivas-Groutz nomogram. Two patients complained about irritative voiding symptoms at catheter removal, which subsided completely and spontaneously after a week. The dorsal approach with buccal mucosa graft allowed us to reconstruct an adequate urethra in females, decreasing the risks of incontinence and fistula.
[Physiology of the urethral sphincteric vesico-prostatic complex].
Carmignani, L; Gadda, F; Dell'Orto, P; Ferruti, M; Grisotto, M; Rocco, F
2001-09-01
We propose a review of the literature about innervation and physiology of the urethral sphincteric complex. Parasympathetic innervation of the pelvic viscera comes from ventral branches of the sacral nerves (S2-S4). The orthosympathetic component derives from superior hypogastric plexus and runs down the hypogastric nerves to form the right and left pelvic plexus together with the parasympathetic component. The pelvic plexus is situated inferolaterally with respect to the rectum and runs on the surface of the levator ani muscle down to the prostatic apex. The pelvic plexus gives innervation to the rectum, the bladder, the prostate and the urethral sphincteric complex. The pelvic muscular floor is innervated by the somatic component (pudendal nerve) derived from the sacral branches (S2-S4). Bladder neck and smooth muscle urethral sphincter innervation is given mostly by the orthosympathetic component. The rhabdosphincter innervation comes from the pudendal nerve and from the pelvic plexus; its role in the continence mechanism is probably to give steady tonic urethral compression. Levator ani muscle takes part in the sphincteric complex with its anteromedial pubococcygeal portion. It plays its role strengthening the sphincteric tone during increase of the abdominal pressure or during active quick stop cessation of the urinary stream.
Gupta, N P; Ansari, M S; Dogra, P N; Tandon, S
2004-06-01
To present the technique of dorsal buccal mucosal graft urethroplasty through a ventral sagittal urethrotomy and minimal access perineal approach for anterior urethral stricture. From July 2001 to December 2002, 12 patients with a long anterior urethral stricture had the anterior urethra reconstructed, using a one-stage urethroplasty with a dorsal onlay buccal mucosal graft through a ventral sagittal urethrotomy. The urethra was approached via a small perineal incision irrespective of the site and length of the stricture. The penis was everted through the perineal wound. No urethral dissection was used on laterally or dorsally, so as not to jeopardize the blood supply. The mean (range) length of the stricture was 5 (3-16) cm and the follow-up 12 (10-16) months. The results were good in 11 of the 12 patients. One patient developed a stricture at the proximal anastomotic site and required optical internal urethrotomy. Dorsal buccal mucosal graft urethroplasty via a minimal access perineal approach is a simple technique with a good surgical outcome; it does not require urethral dissection and mobilization and hence preserves the blood supply.
Posttraumatic posterior urethral strictures in children: a 20-year experience.
Koraitim, M M
1997-02-01
We attempted to identify the particular features of strictures complicating pelvic fracture urethral injuries in children. A total of 68 boys 3 to 15 years old who had sustained pelvic fracture urethral disruption underwent 78 urethroplasties performed by bulboprostatic anastomosis through the perineum in 42, transpubically in 23 and by 2-stage urethroscrotal inlay in 13. Perineal and transurethral urethroplasty was successful in 93 and 91% of cases respectively. There was a 54% failure rate after urethroscrotal inlay. Urethral strictures were most commonly associated with Malgaigne's fracture (35% of cases) and straddle fracture with or without diastasis of the sacroiliac joint (26%). Strictures were almost invariably inferior to the verumontanum with prostatic displacement in 44% of cases. Length of the strictured segment may be overestimated or underestimated on urethrography as a result of incomplete filling of the prostatic urethra or a urinoma cavity connected with the proximal segment, respectively. Perineal or transpubic bulboprostatic anastomosis is the best treatment for posttraumatic strictures, while internal urethrotomy should be avoided since it may compromise the chance of subsequent anastomotic urethroplasty. Repair of associated bladder neck incompetence may be deferred until the resumption of urethral voiding after urethroplasty, when incontinence can be documented.
Incidence of urethral disruption in females with traumatic pelvic fractures.
Carter, C T; Schafer, N
1993-05-01
According to the National Center for Health Statistics, in 1986 1.4 million female patients in the United States were admitted to inpatient and short-stay nonfederal hospitals as a result of injuries acquired secondary to trauma. Of these, 45,000 had traumatic pelvic fractures. Rupture of the urethra is the most important lower urinary tract injury associated with traumatic pelvic fracture because of the high incidence of serious complications, such as urethral stricture and incontinence. To our knowledge, there are no satisfactory studies in the English literature documenting the incidence of urethral disruption in females with traumatic pelvic fractures. The records of all women patients with pelvic fractures registered in the Latter Day Saints Hospital trauma registry between July 1, 1981 and August 31, 1987 were reviewed. Of 146 female patients with traumatic pelvic fractures who were hospitalized during this period, none was found to have an urethral injury. Two patients (1.4%) had bladder contusions, and one (.7%) had a bladder rupture. This was the first large series attempting to identify the true incidence of urethral disruption in females with traumatic pelvic fracture, and it was found to be a rare occurrence.
Tissue engineering in urethral reconstruction—an update
Mangera, Altaf; Chapple, Christopher R
2013-01-01
The field of tissue engineering is rapidly progressing. Much work has gone into developing a tissue engineered urethral graft. Current grafts, when long, can create initial donor site morbidity. In this article, we evaluate the progress made in finding a tissue engineered substitute for the human urethra. Researchers have investigated cell-free and cell-seeded grafts. We discuss different approaches to developing these grafts and review their reported successes in human studies. With further work, tissue engineered grafts may facilitate the management of lengthy urethral strictures requiring oral mucosa substitution urethroplasty. PMID:23042444
Digital single-channel seismic-reflection data from western Santa Monica basin
Normark, William R.; Piper, David J.W.; Sliter, Ray W.; Triezenberg, Peter; Gutmacher, Christina E.
2006-01-01
During a collaborative project in 1992, Geological Survey of Canada and United States Geological Survey scientists obtained about 850 line-km of high-quality single-channel boomer and sleeve-gun seismic-reflection profiles across Hueneme, Mugu and Dume submarine fans, Santa Monica Basin, off southern California. The goals of this work were to better understand the processes that lead to the formation of sandy submarine fans and the role of sea-level changes in controlling fan development. This report includes a trackline map of the area surveyed, as well as images of the sleeve-gun profiles and the opportunity to download both images and digital data files (SEG-Y) of all the sleeve-gun profiles.
Slide release mechanism. [for space shuttle orbiter/external tank connection device
NASA Technical Reports Server (NTRS)
Bunker, J. W.; Ritchie, R. S. (Inventor)
1985-01-01
A releasable support device is described which is comprised of a hollow body with a sleeve extending transversely there-through for receiving the end of a support shank. A slider-latch, optionally lubricated, extends through side recesses in the sleeve to straddle the shank, respectively, in latched and released positions. The slider-latch is slid from its latched to its unlatched position by a pressure squib whereupon a spring or other pressure means pushes the shank out of the sleeve. At the same time, a follower element is lodged in and closed the hole in the body wall from which the shank was discharged. The mechanism was designed for the shuttle orbiter/external tank connection device.
Retention sleeve for a thermal medium carrying tube in a gas turbine
Lathrop, Norman Douglas; Czachor, Robert Paul
2003-01-01
Multiple tubes are connected to steam supply and spent cooling steam return manifolds for supplying cooling steam to buckets and returning spent cooling steam from the buckets to the manifolds, respectively. The tubes are prevented from axial movement in one direction by flanges engaging end faces of the spacer between the first and second-stage wheels. Retention sleeves are disposed about cantilevered ends of the tubes. One end of the retention sleeve engages an enlarged flange on the tube, while an opposite end is spaced axially from an end face of the adjoining wheel, forming a gap, enabling thermal expansion of the tubes and limiting axial displacement of the tube in the opposite direction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leslie, James C.; Leslie, II, James C.; Heard, James
A method for making a metal to composite tube joint including selecting an elongated interior fitting constructed with an exterior barrel, reduced in exterior diameter to form a distally facing annular shoulder and then projecting still further distally to form an interior sleeve having a radially outwardly facing bonding surface. Selecting an elongated metal outer sleeve formed proximally with a collar constructed for receipt over the barrel and increased in interior diameter and projecting distally to form an exterior sleeve having a radially inwardly facing bonding surface cooperating with the first bonding surface to form an annulus receiving an extremitymore » of a composite tube and a bond bonding the extremity of the tube to the bonding surfaces.« less
Fracture of the penis. A report of two cases.
Ugwu, B T; Liman, H U; Sani, A A; Mohammed, A M
2009-06-01
We present two cases of fracture of the penis in two young men at the extremes of the social strata the first an unemployed tailor while the other a practicing engineer. The first one was a bachelor while the other was married with children. In the first case, the fracture occurred during masturbation while in the second case it occurred during consensual intercourse with his wife on top. In the first case the fracture occurred at the base of the penis with associated rupture of the deep dorsal vein while in the second case it affected the mid-shaft with urethral rupture and blood at the tip of the penis at presentation. Both of them presented within two hours of their injuries with deformed, swollen and tender penis. Laubscher's subcoronal sleeve operation with evacuation of clots and repair of the tear with absorbable sutures to ensure a leak-proof repair was promptly performed with no complications. Both patients experienced spontaneous erection whilst in hospital even with indwelling catheter in place. The wife of the second case became pregnant six months after the repair. Counseling was successful with the engineer but was unsuccessful with the tailor-bachelor who continued with masturbation despite professional help. Though we published the first case of fracture of the penis in this centre almost a decade ago, we still found it necessary to report these new cases managed after we created awareness of this uncommon condition in our environment in order to highlight the presentations and the factors that influenced outcome.
Shen, Joel; Overland, Maya; Sinclair, Adriane; Cao, Mei; Yue, Xuan; Cunha, Gerald; Baskin, Laurence
We recently described a two-step process of urethral plate canalization and urethral fold fusion to form the human penile urethra. Canalization ("opening zipper") opens the solid urethral plate into a groove, and fusion ("closing zipper") closes the urethral groove to form the penile urethra. We hypothesize that failure of canalization and/or fusion during human urethral formation can lead to hypospadias. Herein, we use scanning electron microscopy (SEM) and analysis of transverse serial sections to better characterize development of the human fetal penile urethra as contrasted to the development of the human fetal clitoris. Eighteen 7-13 week human fetal external genitalia specimens were analyzed by SEM, and fifteen additional human fetal specimens were sectioned for histologic analysis. SEM images demonstrate canalization of the urethral/vestibular plate in the developing male and female external genitalia, respectively, followed by proximal to distal fusion of the urethral folds in males only. The fusion process during penile development occurs sequentially in multiple layers and through the interlacing of epidermal "cords". Complex epithelial organization is also noted at the site of active canalization. The demarcation between the epidermis of the shaft and the glans becomes distinct during development, and the epithelial tag at the distal tip of the penile and clitoral glans regresses as development progresses. In summary, SEM analysis of human fetal specimens supports the two-zipper hypothesis of formation of the penile urethra. The opening zipper progresses from proximal to distal along the shaft of the penis and clitoris into the glans in identical fashion in both sexes. The closing zipper mechanism is active only in males and is not a single process but rather a series of layered fusion events, uniquely different from the simple fusion of two epithelial surfaces as occurs in formation of the palate and neural tube. Copyright © 2016 International Society of Differentiation. Published by Elsevier B.V. All rights reserved.
Risk Factors for Urinary Tract Infection following Mid Urethral Sling Surgery.
Vigil, Humberto R; Mallick, Ranjeeta; Nitti, Victor W; Lavallée, Luke T; Breau, Rodney H; Hickling, Duane R
2017-05-01
Mid urethral sling surgery is common. Postoperative urinary tract infection rates vary in the literature and independent risk factors for urinary tract infection are not well defined. We sought to determine the incidence of and risk factors for urinary tract infection following mid urethral sling surgery. A retrospective cohort of females who underwent sling surgery was captured from the 2006 to 2014 NSQIP® (National Surgical Quality Improvement Program®) database. Exclusion criteria included male gender, nonelective surgery, totally dependent functional status, preoperative infection, prior surgery within 30 days, ASA® (American Society of Anesthesiologists®) Physical Status Classification 4 or greater, concomitant procedure and operative time greater than 60 minutes. The primary outcome was the incidence of urinary tract infection within 30 days of mid urethral sling surgery. Risk factors for urinary tract infection were assessed by examining patient demographic, comorbidity and surgical variables. Logistic regression analyses were performed to estimate the ORs of individual risk factors. Multivariable logistic regression was then performed to adjust for confounding. A total of 9,022 mid urethral sling surgeries were identified. The urinary tract infection incidence was 2.6%. Factors independently associated with an increased infection risk included age greater than 65 years (OR 1.54, 95% CI 1.07-2.22), body mass index greater than 40 kg/m 2 (OR 1.89, 95% CI 1.23-2.92) and hospital admission (OR 2.06, 95% CI 1.37-3.11). Mid urethral sling surgery performed by urologists carried a reduced risk of infection compared to the surgery done by gynecologists (OR 0.52, 95% CI 0.40-0.69). The urinary tract infection risk following mid urethral sling surgery in NSQIP associated hospitals is low. Novel patient and surgical factors for postoperative urinary tract infection have been identified and merit further study. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Folasire, Oladayo S; Chess-Williams, Russ; Sellers, Donna J
2017-09-01
The urethral uroepithelium has been implicated in urethral sensation and maintenance of continence. However, relatively little is known about the function of the urethral urothelium compared with that of the bladder. The aim of the study was to examine the role of the urothelium/lamina propria on contractility of the porcine urethra, along with the influence of nitric oxide, prostaglandins and ageing. Porcine urethral tissues, intact and denuded of urothelium/lamina propria, were mounted in tissue baths and contractions to noradrenaline, phenylephrine and carbachol obtained. Contractions in the presence of Nώ-nitro-l-arginine (100 μmol/L) and indomethacin (10 μmol/L) were examined, along with contractions of tissues from young (6 months) and older (3 years) animals. The urothelium/lamina propria of the urethra significantly inhibited contractions to carbachol, noradrenaline and phenylephrine. This inhibitory effect was not significantly different for the three agonists (58.7±10.3%, 60.4±12.6% and 39.4±12.2% inhibition; n=4-7), and was also observed when denuded tissues were co-incubated with a second tissue with intact urothelium/lamina propria (40.6±7.5% inhibition; n=6). Inhibition of nitric oxide and prostaglandin production did not attenuate the inhibitory effect of the urothelium/lamina propria on noradrenaline contractions. In addition, ageing did not alter the inhibitory effect for either phenylephrine contractions (33.9±2.2% vs 41.0±9.7%, young vs older urethral tissues) or noradrenaline contractions (32.9±11.1% vs 53.7±11.0%). In conclusion the urothelium/lamina propria of the urethra has an inhibitory effect on receptor-mediated urethral contraction. This inhibition is due to the release of a diffusible factor, and the effect is not mediated by nitric oxide or prostaglandins, or affected by age. © 2017 John Wiley & Sons Australia, Ltd.
Kulkarni, Sanjay B; Barbagli, Guido; Joshi, Pankaj M; Hunter, Craig; Shahrour, Walid; Kulkarni, Jyotsna; Sansalone, Salvatore; Lazzeri, Massimo
2015-05-01
To test the hypothesis that a new surgical technique using elaborated perineal anastomotic urethroplasty combined with laparoscopic omentoplasty for patients with complex and prior failed pelvic fracture urethral defect repair was feasible, safe, and effective. We performed a prospective, observational, stage 2a study to observe treatment outcomes of combined perineal and laparoscopic approach for urethroplasty in patients with pelvic fracture urethral defect at a single center in Pune, India, between January 2012 and February 2013. Complex and redo patients with pelvic fracture urethral defect occurring after pelvic fracture urethral injury were included in the study. Anterior urethral strictures were excluded. The primary study outcome was the success rate of the surgical technique, and the secondary outcome was to evaluate feasibility and safety of the procedure. The clinical outcome was considered a failure when any postoperative instrumentation was needed. Fifteen male patients with a median age of 19 years were included in the study. Seven patients were adolescents (12-18 years) and 8 patients (53.3%) were adults (19-49 years). The mean number of prior urethroplasties was 1.8 (range, 1-3). All patients underwent elaborated bulbomembranous anastomosis using a perineal approach with inferior pubectomy combined with laparoscopic mobilization of the omentum into the perineum to envelope the anastomosis and to fill the perineal dead space. Of 15 patients, 14 (93.3%) were successful and 1 (6.6%) failed. One adolescent boy 14 years old developed a recurrent stricture 2 months after the procedure and was managed using internal urethrotomy. Median follow-up was 18 months (range, 13-24 months). Combining a laparoscopic omentoplasty to a membranobulbar anastomosis for complex and redo pelvic fracture urethral injury is successful, feasible, safe, and with minimal additional morbidity to the patient. The technique has the advantage of a perineal incision and the ability to use the omentum to support the anastomosis. Copyright © 2015 Elsevier Inc. All rights reserved.
Dorsal buccal mucosal graft urethroplasty for anterior urethral stricture by Asopa technique.
Pisapati, V L N Murthy; Paturi, Srimannarayana; Bethu, Suresh; Jada, Srikanth; Chilumu, Ramreddy; Devraj, Rahul; Reddy, Bhargava; Sriramoju, Vidyasagar
2009-07-01
Buccal mucosal graft (BMG) substitution urethroplasty has become popular in the management of intractable anterior urethral strictures with good results. Excellent long-term results have been reported by both dorsal and ventral onlay techniques. Asopa reported a successful technique for dorsal placement of BMG in long anterior urethral strictures through a ventral sagittal approach. To evaluate prospectively the results and advantages of dorsal BMG urethroplasty for recurrent anterior urethral strictures by a ventral sagittal urethrotomy approach (Asopa technique). From December 2002 to December 2007, a total of 58 men underwent dorsal BMG urethroplasty by a ventral sagittal urethrotomy approach for recurrent urethral strictures. Forty-five of these patients with a follow-up period of 12-60 mo were prospectively evaluated, and the results were analysed. The urethra was split twice at the site of the stricture both ventrally and dorsally without mobilising it from its bed, and the buccal mucosal graft was secured in the dorsal urethral defect. The urethra was then retubularised in one stage. The overall results were good (87%), with a mean follow-up period of 42 mo. Seven patients developed minor wound infection, and five patients developed fistulae. There were six recurrences (6:45, 13%) during the follow-up period of 12-60 mo. Two patients with a panurethral stricture and four with bulbar or penobulbar strictures developed recurrences and were managed by optical urethrotomy and self-dilatation. The medium-term results were as good as those reported with the dorsal urethrotomy approach. Long-term results from this and other series are awaited. More randomised trials and meta-analyses are needed to establish this technique as a procedure of choice in future. The ventral sagittal urethrotomy approach is easier to perform than the dorsal urethrotomy approach, has good results, and is especially useful in long anterior urethral strictures.
Djordjevic, Miroslav L; Bizic, Marta R
2013-05-01
Metoidioplasty presents one of the variants of phalloplasty in female transsexuals. Urethral lengthening is the most difficult part in this surgery and poses many challenges. We evaluated 207 patients who underwent metoidioplasty, aiming to compare two different surgical techniques of urethral lengthening, postoperative results, and complications. The study encompassed a total of 207 patients, aged from 18 to 62 years, who underwent single stage metoidioplasty between September 2002 and July 2011. The procedure included lengthening and straightening of the clitoris, urethral reconstruction, and scrotoplasty with implantation of testicular prostheses. Buccal mucosa graft was used in all cases for dorsal urethral plate formation and joined with one of the two different flaps: I-longitudinal dorsal clitoral skin flap (49 patients) and II-labia minora flap (158 patients). Results were analyzed using Z-test to evaluate the statistical difference between the two approaches. Also, postoperative questionnaire was used, which included questions on functioning and esthetical appearance of participating subjects as well as overall satisfaction. The median follow-up was 39 months (ranged 12-116 months). The total length of reconstructed urethra was measured during surgery in both groups. It ranged from 9.1 to 12.3 cm (median 9.5) in group I and from 9.4 to 14.2 cm (median 10.8) in group II. Voiding while standing was significantly better in group II (93%) than in group I (87.82%) (P < 0.05). Urethral fistula occurred in 16 patients in both groups (7.72%). There was statistically significant difference between the groups, with lower incidence in group II (5.69%) vs. group I (14.30%) (P < 0.05). Overall satisfaction was noted in 193 patients. Comparison of the two methods for urethral lengthening confirmed combined buccal mucosa graft and labia minora flap as a method of choice for urethroplasty in metoidioplasty, minimizing postoperative complications. © 2013 International Society for Sexual Medicine.
Early effectiveness of endoscopic posterior urethra primary alignment.
Kim, Fernando J; Pompeo, Alexandre; Sehrt, David; Molina, Wilson R; Mariano da Costa, Renato M; Juliano, Cesar; Moore, Ernest E; Stahel, Philip F
2013-08-01
Posterior urethra primary realignment (PUPR) after complete transection may decrease the gap between the ends of the transected urethra, tamponade the retropubic bleeding, and optimize urinary drainage without the need of suprapubic catheter facilitating concurrent pelvic orthopedic and trauma procedures. Historically, the distorted anatomy after pelvic trauma has been a major surgical challenge. The purpose of the study was to assess the relationship of the severity of the pelvic fracture to the success of endoscopic and immediate PUPR following complete posterior urethral disruption using the Young-Burgess classification system. A review of our Level I trauma center database for patients diagnosed with pelvic fracture and complete posterior urethral disruption from January 2005 to April 2012 was performed. Pelvic fracture severity was categorized according to the Young-Burgees classification system. Management consisted of suprapubic catheter insertion at diagnosis followed by early urethral realignment when the patient was clinically stable. Failure of realignment was defined as inability to achieve urethral continuity with Foley catheterization. Clinical follow-up consisted of radiologic, pressure studies and cystoscopic evaluation. A total of 481 patients with pelvic trauma from our trauma registry were screened initially, and 18 (3.7%) were diagnosed with a complete posterior urethral disruption. A total of 15 primary realignments (83.3%) were performed all within 5 days of trauma. The success rate of early realignment was 100%. There was no correlation between the type of pelvic ring fracture and the success of PUPR. Postoperatively, 8 patients (53.3%) developed urethral strictures, 3 patients (20.0%) developed incontinence, and 7 patients (46.7%) reported erectile dysfunction after the trauma. The mean follow-up of these patients was 31.8 months. Endoscopic PUPR may be an effective option for the treatment of complete posterior urethral disruption and enables urinary drainage to best suit the multispecialty surgical team. The success rate of achieving primary realignment did not appear to be related to the complexity and type of pelvic ring fracture.
... It can also occur after a disease or injury. Rarely, it may be caused by pressure from a growing tumor near the urethra. Other factors that increase the risk for this condition include: Sexually ... Injury to the pelvic area Repeated urethritis Strictures that ...
Direct visual internal urethrotomy: Is it a durable treatment option?
Pal, Dilip Kumar; Kumar, Sanjay; Ghosh, Bastab
2017-01-01
Objective: To evaluate the long-term success rate of direct vision internal urethrotomy as a treatment for anterior urethral strictures. Materials and Methods: We retrospectively analyzed the results for patients who underwent internal urethrotomy from January 2009 to January 2014 for anterior urethral strictures. Patients were followed till January 2016. Patients with complicated urethral strictures with a history of previous urethroplasty, hypospadias repair, or previous radiation were excluded from the study, as anticipated low success rate of direct visual internal urethrotomy (DVIU) in these patients. The Kaplan–Meier method was used to analyze stricture-free probability after the first, second, and third urethrotomy. Results: A total of 186 patients were included in this study. Stricture-free rates after first, second, and third urethrotomy were 29.66%, 22.64%, and 13.33%, respectively. Conclusions: Although DVIU may be a management option for anterior urethral stricture disease, it seems that long-term results are disappointing. PMID:28216923
Direct visual internal urethrotomy: Is it a durable treatment option?
Pal, Dilip Kumar; Kumar, Sanjay; Ghosh, Bastab
2017-01-01
To evaluate the long-term success rate of direct vision internal urethrotomy as a treatment for anterior urethral strictures. We retrospectively analyzed the results for patients who underwent internal urethrotomy from January 2009 to January 2014 for anterior urethral strictures. Patients were followed till January 2016. Patients with complicated urethral strictures with a history of previous urethroplasty, hypospadias repair, or previous radiation were excluded from the study, as anticipated low success rate of direct visual internal urethrotomy (DVIU) in these patients. The Kaplan-Meier method was used to analyze stricture-free probability after the first, second, and third urethrotomy. A total of 186 patients were included in this study. Stricture-free rates after first, second, and third urethrotomy were 29.66%, 22.64%, and 13.33%, respectively. Although DVIU may be a management option for anterior urethral stricture disease, it seems that long-term results are disappointing.
Clinical evaluation of Apamarga-Ksharataila Uttarabasti in the management of urethral stricture
Reddy, K. Rajeshwar
2013-01-01
Stricture urethra, though a rare condition, still is a rational and troublesome problem in the international society. Major complications caused by this disease are obstructed urine flow, urine stasis leading to urinary tract infection, calculi formation, etc. This condition can be correlated with Mutramarga Sankocha in Ayurveda. Modern medical science suggests urethral dilatation, which may cause bleeding, false passage and fistula formation in few cases. Surgical procedures have their own complications and limitations. Uttarabasti, a para-surgical procedure is the most effective available treatment in Ayurveda for the diseases of Mutravaha Strotas. In the present study, total 60 patients of urethral stricture were divided into two groups and treated with Uttarabasti (Group A) and urethral dilatation (Group B). The symptoms like obstructed urine flow, straining, dribbling and prolongation of micturation were assessed before and after treatment. The results of the study were significant on all the parameters. PMID:24250127
Iliac Vein Compression Syndrome due to Bladder Distention Caused by Urethral Calculi
Ikegami, Akiko; Kondo, Takeshi; Tsukamoto, Tomoko; Ohira, Yoshiyuki; Ikusaka, Masatomi
2015-01-01
We report a rare case of iliac vein compression syndrome caused by urethral calculus. A 71-year-old man had a history of urethral stenosis. He complained of bilateral leg edema and dysuria for 1 week. Physical examination revealed bilateral distention of the superficial epigastric veins, so obstruction of both common iliac veins or the inferior vena cava was suspected. Plain abdominal computed tomography showed a calculus in the pendulous urethra, distention of the bladder (as well as the right renal pelvis and ureter), and compression of the bilateral common iliac veins by the distended bladder. Iliac vein compression syndrome was diagnosed. Bilateral iliac vein compression due to bladder distention (secondary to neurogenic bladder, benign prostatic hyperplasia, or urethral calculus as in this case) is an infrequent cause of acute bilateral leg edema. Detecting distention of the superficial epigastric veins provides a clue for diagnosis of this syndrome. PMID:25802794
Weidlich, P; Adam, C; Sroka, R; Lanzl, I; Assmann, W; Stief, C
2007-09-01
The treatment of urethral strictures represents an unsolved urological problem. The effect of a (32)P-coated urethral catheter in the sense of low-dose rate brachytherapy to modulate wound healing will be analyzed in an animal experiment. Unfortunately it is not possible to present any results because this is being studied for the first time and there are no experiences with low-dose rate brachytherapy and this form of application in the lower urinary tract. Furthermore the animal experiment will only start in the near future. Both decade-long experiences with radiotherapy to treat benign diseases and our own results of previous studies in otolaryngology and ophthalmology let us expect a significantly lower formation of urethral strictures after internal urethrotomy. This study will contribute to improving the treatment of urethral strictures as demanded in previous papers.
Pelvic fracture injuries of the female urethra.
Venn, S N; Greenwell, T J; Mundy, A R
1999-04-01
To review pelvic fracture urethral injuries in women, generally regarded as rare and thus discussed infrequently. Twelve patients (age range 7-51 years) with such injuries were reviewed; most had associated injuries, generally more severe than seen in males with urethral injuries. Patients with milder injuries, perhaps damaging just the innervation of the urethra, presented with incontinence; more severe injuries seemed to cause a longitudinal tear in the urethra but again patients presented mainly with incontinence problems. The most severe injuries were associated with complete rupture of the urethra and a distraction defect suggesting an avulsion injury. These problems were difficult to treat both reconstructively and in providing continence. Pelvic fracture urethral injuries occur in females, but less often than in males. The female urethra seems relatively resistant to injury; differing degrees of severity of pelvic trauma cause different types of urethral injury but in general, a more severe injury is needed to damage it than is necessary in males.
Clinical evaluation of Apamarga-Ksharataila Uttarabasti in the management of urethral stricture.
Reddy, K Rajeshwar
2013-04-01
Stricture urethra, though a rare condition, still is a rational and troublesome problem in the international society. Major complications caused by this disease are obstructed urine flow, urine stasis leading to urinary tract infection, calculi formation, etc. This condition can be correlated with Mutramarga Sankocha in Ayurveda. Modern medical science suggests urethral dilatation, which may cause bleeding, false passage and fistula formation in few cases. Surgical procedures have their own complications and limitations. Uttarabasti, a para-surgical procedure is the most effective available treatment in Ayurveda for the diseases of Mutravaha Strotas. In the present study, total 60 patients of urethral stricture were divided into two groups and treated with Uttarabasti (Group A) and urethral dilatation (Group B). The symptoms like obstructed urine flow, straining, dribbling and prolongation of micturation were assessed before and after treatment. The results of the study were significant on all the parameters.
Protection of tree seedlings from deer browsing
Jeffrey S. Ward; George R. Stephens
1995-01-01
Browsing by large deer herds has seriously impaired successful regeneration on some Connecticut forests. Six plots were established in 1990 to examine the effectiveness of 5 deer browsing protection devices for 5 tree species. Protective devices included plastic mesh sleeves (60-cm), Reemay (spunbonded polypropylene) sleeves (60-cm), Tubex tree shelters (120 and 180-cm...
1989-03-01
the embayment indicating extensive inundation by the sea during these epochs. Some Oligocene and Miocene deposits can be found in the southern part of...accurately measure sleeve fric- tion in low-strength materials without careful calibration and equipment warm -up. The tension cone measures sleeve
Hydraulic servo control spool valve
Miller, Donald M.
1983-01-01
A servo operated spool valve having a fixed sleeve and axially movable spool. The sleeve is machined in two halves to form a long, narrow tapered orifice slot across which a transverse wall of the spool is positioned. The axial position of the spool wall along the slot regulates the open orifice area with extreme precision.
Improved material-bagging device
Wach, C.G.; Nelson, R.E.; Brak, S.B.
1982-01-19
A bagging device for transferring material; specifically contaminated material, from one chamber through an opening in a wall to a second chamber includes a cylindrical housing communicating with the opening and defining a passage between the chambers. A cylindrical cartridge is slidably received within the housing. The cartridge has a substantially rigid cylindrical sleeve to which is affixed a pliable tube. The pliable tube is positioned concentrically about the sleeve and has a pleated portion capable of unfolding from the sleeve and a closed end extending over a terminal end of the sleeve. Sealing means are interposed in sealed relationship between the cartridge and the housing. Material from one chamber is inserted into the cartridge secured in the housing and received in the closed end of the tube which unfolds into the other chamber enclosing the material therein. The tube may then be sealed behind the material and then severed to form a bag-like enclosure defined by the tube's closed terminal end and the new seal. The new seal then forms a terminal end for the unsevered portion of the pliable tube into which additional material may be placed and the bagging process repeated.
Wach, Charles G.; Nelson, Robert E.; Brak, Stephen B.
1984-01-01
A bagging device for transferring material from one chamber through an opening in a wall to a second chamber includes a cylindrical housing communicating with the opening and defining a passage between the chambers. A cylindrical cartridge is slidably received within the housing. The cartridge has a substantially rigid cylindrical sleeve to which is affixed a pliable tube. The pliable tube is positioned concentrically about the sleeve and has a pleated portion capable of unfolding from the sleeve and a closed end extending over a terminal end of the sleeve. Sealing means are interposed in sealed relationship between the cartridge and the housing. Material from one chamber is inserted into the cartridge secured in the housing and received in the closed end of the tube which unfolds into the other chamber enclosing the material therein. The tube may then be sealed behind the material and then severed to form a bag-like enclosure defined by the tube's closed terminal end and the new seal. The new seal then forms a terminal end for the unsevered portion of the pliable tube into which additional material may be placed and the bagging process repeated.
Nozzle cavity impingement/area reduction insert
Yu, Yufeng Phillip; Itzel, Gary Michael; Osgood, Sarah Jane
2002-01-01
A turbine vane segment is provided that has inner and outer walls spaced from one another, a vane extending between the inner and outer walls and having leading and trailing edges and pressure and suction sides, the vane including discrete leading edge, intermediate, aft and trailing edge cavities between the leading and trailing edges and extending lengthwise of the vane for flowing a cooling medium; and an insert sleeve within at least one of the cavities and spaced from interior wall surfaces thereof. The insert sleeve has an inlet for flowing the cooling medium into the insert sleeve and has impingement holes defined in first and second walls thereof that respectively face the pressure and suction sides of the vane. The impingement holes of at least one of those first and second walls are defined along substantially only a first, upstream portion thereof, whereby the cooling flow is predominantly impingement cooling along a first region of the insert wall corresponding to the first, upstream portion and the cooling flow is predominantly convective cooling along a second region corresponding to a second, downstream portion of the at least one wall of the insert sleeve.
Obermeyer, F.D.
1993-11-16
Segmented instrumentation tube including a locking sleeve for interlocking the segments of the instrumentation tube, so that the threaded ends of the instrumentation tube do not unthread when subjected to vibration, such an instrumentation tube being suitable for use in a nuclear reactor pressure vessel. The instrumentation tube has a first member having a threaded end portion that has a plurality of first holes circumferentially around the outside surface thereof. The instrumentation tube also has a second member having a threaded end portion that has a plurality of second holes circumferentially around the outside surface thereof. The threads of the second member are caused to threadably engage the threads of the first member for defining a threaded joint there between. A sleeve having an inside surface surrounds the end portion of the first member and the end portion of the second member and thus surrounds the threaded joint. The sleeve includes a plurality of first projections and second projections that outwardly extend from the inside surface to engage the first holes and the second holes, respectively. The outside surface of the sleeve is crimped or swaged at the locations of the first projections and second projections such that the first projections and the second projections engage their respective holes. In this manner, independent rotation of the first member with respect to the second member is prevented, so that the instrumentation tube will not unthread at its threaded joint. 10 figures.
Obermeyer, Franklin D.
1993-01-01
Segmented instrumentation tube including a locking sleeve for interlocking the segments of the instrumentation tube, so that the threaded ends of the instrumentation tube do not unthread when subjected to vibration, such an instrumentation tube being suitable for use in a nuclear reactor pressure vessel. The instrumentation tube has a first member having a threaded end portion that has a plurality of first holes circumferentially around the outside surface thereof. The instrumentation tube also has a second member having a threaded end portion that has a plurality of second holes circumferentially around the outside surface thereof. The threads of the second member are caused to threadably engage the threads of the first member for defining a threaded joint therebetween. A sleeve having an inside surface surrounds the end portion of the first member and the end portion of the second member and thus surrounds the threaded joint. The sleeve includes a plurality of first projections and second projections that outwardly extend from the inside surface to engage the first holes and the second holes, respectively. The outside surface of the sleeve is crimped or swaged at the locations of the first projections and second projections such that the first projections and the second projections engage their respective holes. In this manner, independent rotation of the first member with respect to the second member is prevented, so that the instrumentation tube will not unthread at its threaded joint.
Patellar Sleeve Fracture With Ossification of the Patellar Tendon.
Damrow, Derek S; Van Valin, Scott E
2017-03-01
Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.
Microclimatic Variation Within Sleeve Cages Used in Ecological Studies
Nelson, Lori A.; Rieske, Lynne K.
2014-01-01
Abstract Sleeve cages for enclosing or excluding arthropods are essential components of field studies evaluating trophic interactions. Microclimatic variation in sleeve cages was evaluated to characterize its potential effects on subsequent long-term experiments. Two sleeve cage materials, polyester and nylon, and two cage sizes, 400 and 6000 cm 2 , were tested on eastern hemlock, Tsuga canadensis (L.) Carrière. Temperature and relative humidity inside and outside cages, and the cost and durability of the cage materials, were compared. Long-term effects of the sleeve cages were observed by measuring new growth on T. canadensis branches. The ultimate goal was to identify a material that minimizes bag-induced microclimatic variation. Bagged branches whose microclimates mimic those of surrounding unbagged branches should have minimal effects on plant growth and may prove ideal venues for assessing herbivore and predator behavior under natural conditions. No differences were found in temperature or humidity between caging materials. Small cages had higher average temperatures than large cages, especially in the winter, but this difference was confounded by the fact that small cages were positioned higher in trees than large cages. Differences in plant growth were detected. Eastern hemlock branches enclosed within polyester cages produced fewer new growth tips than uncaged controls. Both polyester and nylon cages reduced the length of new shoot growth relative to uncaged branches. In spite of higher costs, nylon cages were superior to polyester with respect to durability and ease of handling. PMID:25368083