Sample records for urine acetoacetate testing

  1. Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.

    PubMed

    Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr

    2014-01-07

    To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.

  2. Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases

    PubMed Central

    Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr

    2014-01-01

    AIM: To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). METHODS: Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn’s disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student’s t test (α = 0.05). RESULTS: The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. CONCLUSION: NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission. PMID:24415869

  3. Osmotonicity of acetoacetate: possible implications for cerebral edema in diabetic ketoacidosis.

    PubMed

    Puliyel, Jacob M

    2003-04-01

    Rapid drops in blood glucose and sodium levels during treatment of diabetic ketoacidosis (DKA) can cause a drop in the osmotonicity of plasma, resulting in cerebral edema. Ketone bodies are assumed to move freely in and out of cells, so it is assumed that they do not contribute to the tonicity of plasma or influence fluid shifts. The assumption that ketone bodies do not contribute to osmotonicity has not been tested previously. The experiment described here was done to check if acetoacetate has osmotonicity. A modified erythrocyte fragility test was used to check the osmotonic and osmoprotective effects of the ketone body. Red blood cells were suspended in different test tubes containing distilled water, normal saline, glucose, urea and acetoacetic acid (lithium salt C4H5O3Li). All solutions (except the tube with distilled water) were made to match the osmolality of plasma. We hypothesized that solutions in which red cell hemolysis does not take place have greater tonicity than the tonicity of 0.45% saline. Spectrophotometry showed that there was no hemolysis in the solutions of normal saline or solutions containing glucose or acetoacetate. Complete hemolysis was demonstrated in the tube with plain distilled water and also in the solutions containing urea. This study shows that acetoacetate is functionally similar to glucose in that it contributes to increased osmotonicity. The drop in ketone body levels can produce a drop in the osmolar tonicity of plasma and precipitate cerebral edema.

  4. Latent class evaluation of a milk test, a urine test, and the fat-to-protein percentage ratio in milk to diagnose ketosis in dairy cows.

    PubMed

    Krogh, M A; Toft, N; Enevoldsen, C

    2011-05-01

    In this study, 3 commonly used tests to diagnose ketosis were evaluated with a latent class model to avoid the assumption of an available perfect test. The 3 tests were the KetoLac BHB (Sanwa Kagaku Kenkyusho Co. Ltd., Nagoya, Japan) test strip that tests milk for β-hydroxybutyrate, the KetoStix (Bayer Diagnostics Europe Ltd., Dublin, Ireland) test strip that tests urine for acetoacetate, and the fat-to-protein percentage ratio (FPR) in milk. A total of 8,902 cows were included in the analysis. The cows were considered to be a random sample from the population of Danish dairy cattle under intensive management, thus representing a natural spectrum of ketosis as a disease. All cows had a recorded FPR between 7 and 21 d postpartum. The KetoLac BHB recordings were available from 2,257 cows and 6,645 cows had a KetoStix recording. The recordings were analyzed with a modified Hui-Walter model, in a Bayesian framework. The specificity of the KetoLac BHB test and the KetoStix test were both high [0.99 (0.97-0.99)], whereas the specificity of FPR was somewhat lower [0.79 (0.77-0.81)]. The best sensitivity was for the KetoStix test [0.78 (0.55-0.98)], followed by the FPR [0.63 (0.58-0.71)] and KetoLac BHB test [0.58 (0.35-0.93)]. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. A 3-Month Aerobic Training Program Improves Brain Energy Metabolism in Mild Alzheimer's Disease: Preliminary Results from a Neuroimaging Study.

    PubMed

    Castellano, Christian-Alexandre; Paquet, Nancy; Dionne, Isabelle J; Imbeault, Hélène; Langlois, Francis; Croteau, Etienne; Tremblay, Sébastien; Fortier, Mélanie; Matte, J Jacques; Lacombe, Guy; Fülöp, Tamás; Bocti, Christian; Cunnane, Stephen C

    2017-01-01

    Aerobic training has some benefits for delaying the onset or progression of Alzheimer's disease (AD). Little is known about the implication of the brain's two main fuels, glucose and ketones (acetoacetate), associated with thesebenefits. To determine whether aerobic exercise training modifies brain energy metabolism in mild AD. In this uncontrolled study, ten patients with mild AD participated in a 3-month, individualized, moderate-intensity aerobic training on a treadmill (Walking). Quantitative measurement of brain uptake of glucose (CMRglu) and acetoacetate (CMRacac) using neuroimaging and cognitive testing were done before and after the Walking program. Four men and six women with an average global cognitive score (MMSE) of 26/30 and an average age of 73 y completed the Walking program. Average total distance and treadmill speed were 8 km/week and 4 km/h, respectively. Compared to the Baseline, after Walking, CMRacac was three-fold higher (0.6±0.4 versus 0.2±0.1 μmol/100 g/min; p = 0.01). Plasma acetoacetate concentration and the blood-to-brain acetoacetate influx rate constant were also increased by 2-3-fold (all p≤0.03). CMRglu was unchanged after Walking (28.0±0.1 μmol/100 g/min; p = 0.96). There was a tendency toward improvement in the Stroop-color naming test (-10% completion time, p = 0.06). Performance on the Trail Making A&B tests was also directly related to plasma acetoacetate and CMRacac (all p≤0.01). In mild AD, aerobic training improved brain energy metabolism by increasing ketone uptake and utilization while maintaining brain glucose uptake, and could potentially be associated with some cognitive improvement.

  6. Urinary Metabolomic Approach Provides New Insights into Distinct Metabolic Profiles of Glutamine and N-Carbamylglutamate Supplementation in Rats.

    PubMed

    Liu, Guangmang; Cao, Wei; Fang, Tingting; Jia, Gang; Zhao, Hua; Chen, Xiaoling; Wu, Caimei; Wang, Jing

    2016-08-04

    Glutamine and N-carbamylglutamate can enhance growth performance and health in animals, but the underlying mechanisms are not yet elucidated. This study aimed to investigate the effect of glutamine and N-carbamylglutamate supplementation in rat metabolism. Thirty rats were fed a control, glutamine, or N-carbamylglutamate diet for four weeks. Urine samples were analyzed by nuclear magnetic resonance (NMR)-based metabolomics, specifically high-resolution ¹H NMR metabolic profiling combined with multivariate data analysis. Glutamine significantly increased the urine levels of acetamide, acetate, citrulline, creatinine, and methymalonate, and decreased the urine levels of ethanol and formate (p < 0.05). Moreover, N-carbamylglutamate significantly increased the urine levels of creatinine, ethanol, indoxyl sulfate, lactate, methymalonate, acetoacetate, m-hydroxyphenylacetate, and sarcosine, and decreased the urine levels of acetamide, acetate, citrulline, creatine, glycine, hippurate, homogentisate, N-acetylglutamate, phenylacetyglycine, acetone, and p-hydroxyphenylacetate (p < 0.05). Results suggested that glutamine and N-carbamylglutamate could modify urinary metabolome related to nitrogen metabolism and gut microbiota metabolism. Moreover, N-carbamylglutamate could alter energy and lipid metabolism. These findings indicate that different arginine precursors may lead to differences in the biofluid profile in rats.

  7. Urinary Metabolomic Approach Provides New Insights into Distinct Metabolic Profiles of Glutamine and N-Carbamylglutamate Supplementation in Rats

    PubMed Central

    Liu, Guangmang; Cao, Wei; Fang, Tingting; Jia, Gang; Zhao, Hua; Chen, Xiaoling; Wu, Caimei; Wang, Jing

    2016-01-01

    Glutamine and N-carbamylglutamate can enhance growth performance and health in animals, but the underlying mechanisms are not yet elucidated. This study aimed to investigate the effect of glutamine and N-carbamylglutamate supplementation in rat metabolism. Thirty rats were fed a control, glutamine, or N-carbamylglutamate diet for four weeks. Urine samples were analyzed by nuclear magnetic resonance (NMR)-based metabolomics, specifically high-resolution 1H NMR metabolic profiling combined with multivariate data analysis. Glutamine significantly increased the urine levels of acetamide, acetate, citrulline, creatinine, and methymalonate, and decreased the urine levels of ethanol and formate (p < 0.05). Moreover, N-carbamylglutamate significantly increased the urine levels of creatinine, ethanol, indoxyl sulfate, lactate, methymalonate, acetoacetate, m-hydroxyphenylacetate, and sarcosine, and decreased the urine levels of acetamide, acetate, citrulline, creatine, glycine, hippurate, homogentisate, N-acetylglutamate, phenylacetyglycine, acetone, and p-hydroxyphenylacetate (p < 0.05). Results suggested that glutamine and N-carbamylglutamate could modify urinary metabolome related to nitrogen metabolism and gut microbiota metabolism. Moreover, N-carbamylglutamate could alter energy and lipid metabolism. These findings indicate that different arginine precursors may lead to differences in the biofluid profile in rats. PMID:27527211

  8. Deuterium Exchange in Ethyl Acetoacetate: An Undergraduate GC-MS [Gas Chromatography-Mass Spectroscopy] Experiment

    ERIC Educational Resources Information Center

    Heinson, C. D.; Williams, J. M.; Tinnerman, W. N.; Malloy, T. B.

    2005-01-01

    The role of ethanol O-d in nullifying the deuterolysis may be demonstrated by determining that transesterification of methyl acetoacetate of the ethyl ester occurs as well as deuterium exchange of the five acetoacetate hydrogens. The significant acidity of the methylene protons in the acetoacetate group, the efficacy of base catalysis, the role of…

  9. Usefulness of postmortem biochemistry in identification of ketosis: Diagnosis of ketoacidosis at the onset of autoimmune type 1 diabetes in an autopsy case with cold exposure and malnutrition.

    PubMed

    Tani, Naoto; Michiue, Tomomi; Chen, Jian-Hua; Oritani, Shigeki; Ishikawa, Takaki

    2016-09-01

    A severely malnourished, Japanese female in her twenties was found dead in her apartment. On autopsy, most of the findings from the internal examination were suggestive of hypothermia. Postmortem biochemistry, however, showed severely increased levels of glycated hemoglobin (HbA1c) and blood and urine glucose levels. Levels of acetone, 3-hydroxybutyric acid, and acetoacetate in various body fluids were also highly increased, indicating ketosis. The serum insulin and c-peptide levels were severely low, and subsequent testing was positive for anti-GAD antibodies. Immunohistochemical examination of the pancreatic islet cells revealed few insulin-positive cells but many glucagon-positive cells on staining. Furthermore, slight invasion of CD8-positive lymphocytes in the pancreatic islets of Langerhans was observed. Results of immunostaining of the pancreatic and bronchial epithelial tissues were partly positive for the Influenza A virus. We concluded that severe ketoacidosis associated with rapid-onset hyperglycemia due to autoimmune type 1 diabetes (AT1D) had occurred shortly before death. However, the ketosis was accompanied by hypothermia and malnutrition as well as diabetic ketoacidosis (DKA). Therefore, we retrospectively collected biochemical data on cases of hypothermia and malnutrition and compared them with the present case. Serum glucose, acetone, 3-hydroxybutyric acid, and acetoacetic acid can be used for screening and diagnosis to distinguish DKA from ketosis due to hypothermia and malnutrition. Therefore, in the present case, we diagnosed that the natural cause of death was due to AT1D. In conclusion, screening investigations for relevant biochemical markers can provide essential information for the diagnosis of metabolic disturbances, which fail to demonstrate characteristic autopsy findings. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. [Pyroglutamic acidemia associated with acetaminophen].

    PubMed

    Alados Arboledas, F J; de la Oliva Senovilla, P; García Muñoz, Ma J; Alonso Melgar, A; Ruza Tarrío, F

    2007-12-01

    We report a case of pyroglutamic acidemia probably related to acetaminophen administration. A 16-month boy recovering from hemolytic uremic syndrome abruptly developed unexplained high anion gap metabolic acidosis requiring hemodialysis. Septic shock, lactic acidosis and salicylate intoxication were ruled out. Betahydroxybutyrate and acetoacetate levels were within the normal range. No osmolarity gap or high amino acid levels were found. Urine and blood pyroglutamic acid levels were 392 mmol/mol creatinine (reference range: 9-55) and 9.8 mmol/L (reference range<0.16), respectively. The patient was receiving acetaminophen. We conclude that pyroglutamic acidosis should be considered in patients receiving acetaminophen who abruptly develop high anion gap metabolic acidosis not attributable to more common causes.

  11. Hyperpolarized ketone body metabolism in the rat heart.

    PubMed

    Miller, Jack J; Ball, Daniel R; Lau, Angus Z; Tyler, Damian J

    2018-06-01

    The aim of this work was to investigate the use of 13 C-labelled acetoacetate and β-hydroxybutyrate as novel hyperpolarized substrates in the study of cardiac metabolism. [1- 13 C]Acetoacetate was synthesized by catalysed hydrolysis, and both it and [1- 13 C]β-hydroxybutyrate were hyperpolarized by dissolution dynamic nuclear polarization (DNP). Their metabolism was studied in isolated, perfused rat hearts. Hyperpolarized [1- 13 C]acetoacetate metabolism was also studied in the in vivo rat heart in the fed and fasted states. Hyperpolarization of [1- 13 C]acetoacetate and [1- 13 C]β-hydroxybutyrate provided liquid state polarizations of 8 ± 2% and 3 ± 1%, respectively. The hyperpolarized T 1 values for the two substrates were 28 ± 3 s (acetoacetate) and 20 ± 1 s (β-hydroxybutyrate). Multiple downstream metabolites were observed within the perfused heart, including acetylcarnitine, citrate and glutamate. In the in vivo heart, an increase in acetylcarnitine production from acetoacetate was observed in the fed state, as well as a potential reduction in glutamate. In this work, methods for the generation of hyperpolarized [1- 13 C]acetoacetate and [1- 13 C]β-hydroxybutyrate were investigated, and their metabolism was assessed in both isolated, perfused rat hearts and in the in vivo rat heart. These preliminary investigations show that DNP can be used as an effective in vivo probe of ketone body metabolism in the heart. © 2018 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  12. Human forearm metabolism during progressive starvation.

    PubMed

    Owen, O E; Reichard, G A

    1971-07-01

    Forearm muscle metabolism was studied in eight obese subjects after an overnight, 3 and 24 day fast. Arterio-deep-venous differences of oxygen, carbon dioxide, glucose, lactate, pyruvate, free fatty acids, acetoacetate, and beta-hydroxybutyrate with simultaneous forearm blood flow were measured. Rates of metabolite utilization and production were thus estimated. Oxygen consumption and lactate and pyruvate production remained relatively constant at each fasting period. Glucose, initially the major substrate consumed, showed decreased consumption after 3 and 24 days of fasting. Acetoacetate and beta-hydroxybutyrate consumption after an overnight fast was low. At 3 days of fasting with increased arterial concentrations of acetoactate and beta-hydroxybutyrate, consumption of these substrates rose dramatically. At 24 days of fasting, despite further elevation of arterial levels of acetoacetate and beta-hydroxybutyrate, the utilization of acetoacetate did not increase further and if anything decreased, while five out of eight subjects released beta-hydroxybutyrate across the forearm. Acetoacetate was preferentially extracted over beta-hydroxybutyrate. At 24 days of starvation, free fatty acids were the principal fuels extracted by forearm muscle; at this time there was a decreased glucose and also ketone-body consumption by skeletal muscle.

  13. Condensation of anhydrides or dicarboxylic acids with compounds containing active methylene groups. Part 1: Condensation of phthalic anhydride with acetoacetic and malonic ester

    NASA Technical Reports Server (NTRS)

    Oshkaya, V. P.; Vanag, G. Y.

    1985-01-01

    Phthalic anhydride was condensed with acetoacetic ester in acetic anhydride and triethylamine solution, and when phthalyl chloride was reacted with sodium acetoacetic ester compounds were formed of the phthalide and indandione series: phthalylacetoacetic ester and a derivative of indan-1,3-dione which after boiling with hydrochloric acid yielded indan-1,3-dione. Phthalylmalonic ester was obtained from phthalic anhydride and malonic ester in the presence of triethylamine.

  14. Brain glucose and acetoacetate metabolism: a comparison of young and older adults.

    PubMed

    Nugent, Scott; Tremblay, Sebastien; Chen, Kewei W; Ayutyanont, Napatkamon; Roontiva, Auttawut; Castellano, Christian-Alexandre; Fortier, Melanie; Roy, Maggie; Courchesne-Loyer, Alexandre; Bocti, Christian; Lepage, Martin; Turcotte, Eric; Fulop, Tamas; Reiman, Eric M; Cunnane, Stephen C

    2014-06-01

    The extent to which the age-related decline in regional brain glucose uptake also applies to other important brain fuels is presently unknown. Ketones are the brain's major alternative fuel to glucose, so we developed a dual tracer positron emission tomography protocol to quantify and compare regional cerebral metabolic rates for glucose and the ketone, acetoacetate. Twenty healthy young adults (mean age, 26 years) and 24 healthy older adults (mean age, 74 years) were studied. In comparison with younger adults, older adults had 8 ± 6% (mean ± SD) lower cerebral metabolic rates for glucose in gray matter as a whole (p = 0.035), specifically in several frontal, temporal, and subcortical regions, as well as in the cingulate and insula (p ≤ 0.01, false discovery rate correction). The effect of age on cerebral metabolic rates for acetoacetate in gray matter did not reach significance (p = 0.11). Rate constants (min(-1)) of glucose (Kg) and acetoacetate (Ka) were significantly lower (-11 ± 6%; [p = 0.005], and -19 ± 5%; [p = 0.006], respectively) in older adults compared with younger adults. There were differential effects of age on Kg and Ka as seen by significant interaction effects in the caudate (p = 0.030) and post-central gyrus (p = 0.023). The acetoacetate index, which expresses the scaled residuals of the voxel-wise linear regression of glucose on ketone uptake, identifies regions taking up higher or lower amounts of acetoacetate relative to glucose. The acetoacetate index was higher in the caudate of young adults when compared with older adults (p ≤ 0.05 false discovery rate correction). This study provides new information about glucose and ketone metabolism in the human brain and a comparison of the extent to which their regional use changes during normal aging. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. The interconversion and disposal of ketone bodies in untreated and injured post-absorptive rats

    PubMed Central

    Barton, Roger N.

    1973-01-01

    [3-14C]Acetoacetate and β-hydroxy[3-14C]butyrate were used to investigate the kinetics of ketone body metabolism in rats 3h after bilateral hind-limb ischaemia and in controls, both groups being in the post-absorptive state and in a 20°C environment. Calculations were carried out as described by Heath & Barton (1973) and the following conclusions were reached. 1. In both injured and control rats, the rates of irreversible disposal (extrahepatic utilization) of β-hydroxybutyrate and acetoacetate were proportional within experimental error to their blood concentrations up to at least 0.4mm (the maximum found in these rats), implying that they were determined, via these concentrations, by the rates of production by the liver. 2. Conversion of blood β-hydroxybutyrate into blood acetoacetate took place mainly in the liver, but the reverse process occurred mainly in extrahepatic tissues. 3. The `metabolic clearance rate' (the volume of blood which, if completely cleared of substrate in unit time, would give a disposal rate equal to that in the whole animal) was calculated for β-hydroxybutyrate and acetoacetate. Comparison with the cardiac output showed that in control rats the proportion of circulating β-hydroxybutyrate extracted was lower than that of acetoacetate, clearance of which appeared almost complete. After injury both metabolic clearance rates decreased, probably because of the lower cardiac output. 4. After injury, because the average blood concentrations of ketone bodies, especially acetoacetate, were higher, the mean total rate of disposal also increased. Assuming complete oxidation, the mean contribution of ketone bodies to the whole body O2 consumption rose from 7 to 15%. PMID:4798577

  16. The interconversion and disposal of ketone bodies in untreated and injured post-absorptive rats.

    PubMed

    Barton, R N

    1973-11-01

    [3-(14)C]Acetoacetate and beta-hydroxy[3-(14)C]butyrate were used to investigate the kinetics of ketone body metabolism in rats 3h after bilateral hind-limb ischaemia and in controls, both groups being in the post-absorptive state and in a 20 degrees C environment. Calculations were carried out as described by Heath & Barton (1973) and the following conclusions were reached. 1. In both injured and control rats, the rates of irreversible disposal (extrahepatic utilization) of beta-hydroxybutyrate and acetoacetate were proportional within experimental error to their blood concentrations up to at least 0.4mm (the maximum found in these rats), implying that they were determined, via these concentrations, by the rates of production by the liver. 2. Conversion of blood beta-hydroxybutyrate into blood acetoacetate took place mainly in the liver, but the reverse process occurred mainly in extrahepatic tissues. 3. The ;metabolic clearance rate' (the volume of blood which, if completely cleared of substrate in unit time, would give a disposal rate equal to that in the whole animal) was calculated for beta-hydroxybutyrate and acetoacetate. Comparison with the cardiac output showed that in control rats the proportion of circulating beta-hydroxybutyrate extracted was lower than that of acetoacetate, clearance of which appeared almost complete. After injury both metabolic clearance rates decreased, probably because of the lower cardiac output. 4. After injury, because the average blood concentrations of ketone bodies, especially acetoacetate, were higher, the mean total rate of disposal also increased. Assuming complete oxidation, the mean contribution of ketone bodies to the whole body O(2) consumption rose from 7 to 15%.

  17. Lipase-catalyzed synthesis of partial acylglycerols of acetoacetate

    USDA-ARS?s Scientific Manuscript database

    A commercially available immobilized preparation of Rhizomucor miehei lipase (Lipozyme RMIM) has been employed in the synthesis of partial glycerides of acetoacetate. Due to the chemical reactivitity of the acetoacetyl group, these glycerides could have novel uses in e.g. polymer formation. Both 1...

  18. Toxicological effects of cinnabar in rats by NMR-based metabolic profiling of urine and serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wei Lai; Liao Peiqiu; Wu Huifeng

    2008-03-15

    Cinnabar, an important traditional Chinese mineral medicine, has been widely used as a Chinese patent medicine ingredient for sedative therapy. However, the pharmaceutical and toxicological effects of cinnabar, especially in the whole organism, were subjected to few investigations. In this study, an NMR-based metabolomics approach has been applied to investigate the toxicological effects of cinnabar after intragastrical administration (dosed at 0.5, 2 and 5 g/kg body weight) on male Wistar rats. Liver and kidney histopathology examinations and serum clinical chemistry analyses were also performed. The {sup 1}H NMR spectra were analyzed using multivariate pattern recognition techniques to show the time-more » and dose-dependent biochemical variations induced by cinnabar. The metabolic signature of urinalysis from cinnabar-treated animals exhibited an increase in the levels of creatinine, acetate, acetoacetate, taurine, hippurate and phenylacetylglycine, together with a decrease in the levels of trimethyl-N-oxide, dimethylglycine and Kreb's cycle intermediates (citrate, 2-oxoglutarate and succinate). The metabolomics analyses of serum showed elevated concentrations of ketone bodies (3-D-hydroxybutyrate and acetoacetate), branched-chain amino acids (valine, leucine and isoleucine), choline and creatine as well as decreased glucose, lipids and lipoproteins from cinnabar-treated animals. These findings indicated cinnabar induced disturbance in energy metabolism, amino acid metabolism and gut microflora environment as well as slight injury in liver and kidney, which might indirectly result from cinnabar induced oxidative stress. This work illustrated the high reliability of NMR-based metabolomic approach on the study of the biochemical effects induced by traditional Chinese medicine.« less

  19. Rapid Intravenous Sodium Acetoacetate Infusion in Man METABOLIC AND KINETIC RESPONSES

    PubMed Central

    Owen, O. E.; Reichard, G. A.; Markus, H.; Boden, G.; Mozzoli, M. A.; Shuman, C. R.

    1973-01-01

    The metabolic and kinetic responses to rapidly intravenously administered sodium acetoacetate (1.0 mmol/kg body wt) was studied after an overnight fast in 12 male and female adults weighing between 88 and 215% of average body weight. Blood was obtained before, during, and after the infusion for determination of circulating concentrations of immunoreactive insulin, glucose, acetoacetate, β-hydroxybutyrate and free fatty acids. In three obese subjects the studies were repeated after 3 and 24 days of total starvation. After the overnight fast acetoacetate rose rapidly reaching a peak concentration at the end of the infusion; β-hydroxybutyrate concentrations also increased rapidly and exceeded those of acetoacetate 10 min postinfusion. Total ketone body concentration at the end of the infusion period was comparable to that found after prolonged starvation. After the initial mixing period, acetoacetate, β-hydroxybutyrate and total ketone bodies rapidly declined in a parallel manner. There were no obvious differences between the subjects with regard to their blood concentrations of ketone bodies. The mean plasma free fatty acid concentration decreased significantly during the 20th to 90th min postinfusion period; for example the control concentration of 0.61 mmol/liter fell to 0.43 mmol/liter at 60 min. In the three obese subjects studied repeatedly, fasting plasma free fatty acids decreased with acetoacetate infusion from 0.92 to 0.46 mmol/liter after the 3 day fast and from 1.49 to 0.71 mmol/liter after the 24 day fast. Acetoacetate infusion caused no changes in blood glucose concentration after an overnight fast. However, in the three obese subjects restudied after 3- and 24-day fasts blood glucose decreased, respectively, from 3.49 to 3.22 mmol/liter and from 4.07 to 3.49 mmol/liter. The mean serum insulin concentration in all subjects significantly increased from 21 to 46 μU/ml at the completion of the infusion and rapidly declined. In the three obese subjects restudied after 3- and 24-day fasts an approximate two-fold increase of serum insulin was observed after each acetoacetate infusion. The mean fractional utilization rate of exogenously derived ketone bodies for all 12 subjects after an overnight fast was 2.9% min-1. In the three obese subjects studied after an overnight, 3 and 24 day fast the mean fractional utilization rates were 2.1%, 1.5%, and 0.6% min-1, respectively. Ketone body volumes of distribution in the overnight fasted subjected varied from about 18% to 31% of body wt, suggesting that ketone bodies are not homogenously distributed in the body water. In the three obese subjects restudied after 3- and 24-day fasts volumes of distribution remained approximately constant. When total ketone body concentrations in the blood were below 2.0 mmol/liter, there was a linear relationship between ketone body utilization rates and ketone body concentrations; no correlation was found when blood concentrations were higher. Images PMID:4729054

  20. A systematic review and meta-analysis of the diagnostic accuracy of point-of-care tests for the detection of hyperketonemia in dairy cows.

    PubMed

    Tatone, Elise H; Gordon, Jessica L; Hubbs, Jessie; LeBlanc, Stephen J; DeVries, Trevor J; Duffield, Todd F

    2016-08-01

    Several rapid tests for use on farm have been validated for the detection of hyperketonemia (HK) in dairy cattle, however the reported sensitivity and specificity of each method varies and no single study has compared them all. Meta-analysis of diagnostic test accuracy is becoming more common in human medical literature but there are few veterinary examples. The objective of this work was to perform a systematic review and meta-analysis to determine the point-of-care testing method with the highest combined sensitivity and specificity, the optimal threshold for each method, and to identify gaps in the literature. A comprehensive literature search resulted in 5196 references. After removing duplicates and performing relevance screening, 23 studies were included for the qualitative synthesis and 18 for the meta-analysis. The three index tests evaluated in the meta-analysis were: the Precision Xtra(®) handheld device measuring beta-hydroxybutyrate (BHB) concentration in whole blood, and Ketostix(®) and KetoTest(®) semi-quantitative strips measuring the concentration of acetoacetate in urine and BHB in milk, respectively. The diagnostic accuracy of the 3 index tests relative to the reference standard measurement of BHB in serum or whole blood between 1.0-1.4mmol/L was compared using the hierarchical summary receiver operator characteristic (HSROC) method. Subgroup analysis was conducted for each index test to examine the accuracy at different thresholds. The impact of the reference standard threshold, the reference standard method, the prevalence of HK in the population, the primary study source and risk of bias of the primary study was explored using meta-regression. The Precision Xtra(®) device had the highest summary sensitivity in whole blood BHB at 1.2mmol/L, 94.8% (CI95%: 92.6-97.0), and specificity, 97.5% (CI95%: 96.9-98.1). The threshold employed (1.2-1.4mmol/L) did not impact the diagnostic accuracy of the test. The Ketostix(®) and KetoTest(®) strips had the highest summary sensitivity and specificity when the trace and weak positive thresholds were used, respectively. Controlling for the source of publication, HK prevalence and reference standard employed did not impact the estimated sensitivity and specificity of the tests. Including only peer-reviewed studies reduced the number of primary studies evaluating the Precision Xtra(®) by 43% and Ketostix(®) by 33%. Diagnosing HK with blood, urine or milk are valid options, however, the diagnostic inaccuracy of urine and milk should be considered when making economic and treatment decisions. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Utilization of ketone bodies by chick brain and spinal cord during embryonic and postnatal development.

    PubMed

    Linares, A; Caamaño, G J; Diaz, R; Gonzalez, F J; Garcia-Peregrin, E

    1993-10-01

    Lipid synthesis from acetoacetate and 3-hydroxybutyrate was studied in chick embryo from 15 to 21 days and in chick neonate from 1 to 21 days. Embryonic spinal cord showed higher ability than brain to incorporate acetoacetate into total lipids, although a sharp decrease was found at hatching. 3-Hydroxybutyrate incorporation into total lipids was also higher in spinal cord than in brain, especially during the embryonic period. Phospholipids were the main lipids formed in both tissues from both precursors. An appreciable percentage of radioactivity was also recovered as free cholesterol, especially during the embryonic phase. The developmental patterns of amino acid synthesis from acetoacetate and 3-hydroxybutyrate were similar in both tissues: a clear increase after hatching was followed by a decrease at day 4 of neonatal life. Acetoacetate was a better substrate for amino acid synthesis than 3-hydroxybutyrate during the embryonic development in both tissues. Oxidation of both precursors to CO2 strongly decreased between 15 and 21 days of embryonic development both in brain and spinal cord.

  2. Acetoacetate is a more efficient energy-yielding substrate for human mesenchymal stem cells than glucose and generates fewer reactive oxygen species.

    PubMed

    Board, Mary; Lopez, Colleen; van den Bos, Christian; Callaghan, Richard; Clarke, Kieran; Carr, Carolyn

    2017-07-01

    Stem cells have been assumed to demonstrate a reliance on anaerobic energy generation, suited to their hypoxic in vivo environment. However, we found that human mesenchymal stem cells (hMSCs) have an active oxidative metabolism with a range of substrates. More ATP was consistently produced from substrate oxidation than glycolysis by cultured hMSCs. Strong substrate preferences were shown with the ketone body, acetoacetate, being oxidised at up to 35 times the rate of glucose. ROS-generation was 45-fold lower during acetoacetate oxidation compared with glucose and substrate preference may be an adaptation to reduce oxidative stress. The UCP2 inhibitor, genipin, increased ROS production with either acetoacetate or glucose by 2-fold, indicating a role for UCP2 in suppressing ROS production. Addition of pyruvate stimulated acetoacetate oxidation and this combination increased ATP production 27-fold, compared with glucose alone, which has implications for growth medium composition. Oxygen tension during culture affected metabolism by hMSCs. Between passages 2 and 5, rates of both glycolysis and substrate-oxidation increased at least 2-fold for normoxic (20% O 2 )- but not hypoxic (5% O 2 )-cultured hMSCs, despite declining growth rates and no detectable signs of differentiation. Culture of the cells with 3-hydroxybutyrate abolished the increased rates of these pathways. These findings have implications for stem cell therapy, which necessarily involves in vitro culture of cells, since low passage number normoxic cultured stem cells show metabolic adaptations without detectable changes in stem-like status. Copyright © 2017. Published by Elsevier Ltd.

  3. Concentrations of ketone bodies in the blood of the green lizard Ameiva ameiva (Teiidae) in different physiological situations.

    PubMed

    Pontes, R de C; Cartaxo, A C; Jonas, R

    1988-01-01

    1. The concentrations of acetoacetate and 3-hydroxybutyrate have been determined in the blood of the green lizard Ameiva ameiva (Teiidae) in fed animals and in animals starved for periods from one week to about four months. 2. The concentrations of acetoacetate are low and unaltered in fed and starved animals, being in the range from 0.014 to 0.018 mM. 3. The concentrations of 3-hydroxybutyrate are high: 2.67 mM, in fed animals, falling during starvation down to 0.26 mM. 4. The 3-hydroxybutyrate/acetoacetate ratio is high, 151, in fed animals, falling down to 17. 5. The possible importance of ketone bodies in the metabolism of Ameiva ameiva is discussed.

  4. Acetone production by methylobacteria.

    PubMed

    Thomson, A W; O'Neill, J G; Wilkinson, J F

    1976-09-01

    An accumulation of acetone was observed during the metabolism of ethane and products of ethane oxidation by washed suspensions of Methylosinus trichosporium OB3B. This strain possessed an acetoacetate decarboxylase and 3-hydroxybutyrate dehydrogenase, and a decline in poly-beta-hydroxybutyric acid occurred under the same conditions as acetone formation. A pathway of acetone production from poly-beta-hydroxybutyric acid via 3-hydroxybutyrate and acetoacetate was suggested.

  5. Purification and functional characterisation of the pyruvate (monocarboxylate) carrier from baker's yeast mitochondria (Saccharomyces cerevisiae).

    PubMed

    Nałecz, M J; Nałecz, K A; Azzi, A

    1991-08-09

    Isolated yeast mitochondria were subjected to solubilization by Triton X-114 and the detergent extract was subsequently chromatrographed on dry hydroxyapatite. Purification of the yeast monocarboxylate (pyruvate) carrier was achieved by affinity chromatography on immobilized 2-cyano-4-hydroxycinnamate, as described previously for bovine heart mitochondria (Bolli, R., Nałecz K.A. and Azzi, A. (1989) J. Biol. Chem. 264 18024-18030). The final preparation contained two polypeptides of apparent molecular mass 26 and 50 kDa. The yeast carrier appeared to be less abundant, but more active, than the analogous protein from higher eukaryotes. The carrier was able to catalyse the pyruvate / pyruvate and pyruvate / acetoacetate exchange reactions, both reactions being sensitive to cyanocinnamate and its derivatives, to phenylpyruvate and to mersalyl and p-chloromercuribenzoate. In the pyruvate / acetoacetate exchange reaction (200 mM internal acetoacetate, enzymatic assay), the Km value for external pyruvate was found to be 0.8 mM and the Vmax 135 mumol/min per mg protein. Among other substrates of the yeast carrier, all transported with similar affinity and identical maximal velocity against acetoacetate, we identified 2-oxoisocaproate, 2-oxoisovalerate and 2-oxo-3-methylvalerate. Lactate was not translocated by this carrier with a measurable rate, neither were di- or tricarboxylates.

  6. Acetoacetate protects hippocampal neurons against glutamate-mediated neuronal damage during glycolysis inhibition.

    PubMed

    Massieu, L; Haces, M L; Montiel, T; Hernández-Fonseca, K

    2003-01-01

    Glucose is the main substrate that fulfills energy brain demands. However, in some circumstances, such as diabetes, starvation, during the suckling period and the ketogenic diet, brain uses the ketone bodies, acetoacetate and beta-hydroxybutyrate, as energy sources. Ketone body utilization in brain depends directly on its blood concentration, which is normally very low, but increases substantially during the conditions mentioned above. Glutamate neurotoxicity has been implicated in neurodegeneration associated with brain ischemia, hypoglycemia and cerebral trauma, conditions related to energy failure, and to elevation of glutamate extracellular levels in brain. In recent years substantial evidence favoring a close relation between glutamate neurotoxic potentiality and cellular energy levels, has been compiled. We have previously demonstrated that accumulation of extracellular glutamate after inhibition of its transporters, induces neuronal death in vivo during energy impairment induced by glycolysis inhibition. In the present study we have assessed the protective potentiality of the ketone body, acetoacetate, against glutamate-mediated neuronal damage in the hippocampus of rats chronically treated with the glycolysis inhibitor, iodoacetate, and in hippocampal cultured neurons exposed to a toxic concentration of iodoacetate. Results show that acetoacetate efficiently protects against glutamate neurotoxicity both in vivo and in vitro probably by a mechanism involving its role as an energy substrate.

  7. Is the formula of Traub still up to date in antemortem blood glucose level estimation?

    PubMed

    Palmiere, Cristian; Sporkert, Frank; Vaucher, Paul; Werner, Dominique; Bardy, Daniel; Rey, François; Lardi, Christelle; Brunel, Christophe; Augsburger, Marc; Mangin, Patrice

    2012-05-01

    According to the hypothesis of Traub, also known as the 'formula of Traub', postmortem values of glucose and lactate found in the cerebrospinal fluid or vitreous humor are considered indicators of antemortem blood glucose levels. However, because the lactate concentration increases in the vitreous and cerebrospinal fluid after death, some authors postulated that using the sum value to estimate antemortem blood glucose levels could lead to an overestimation of the cases of glucose metabolic disorders with fatal outcomes, such as diabetic ketoacidosis. The aim of our study, performed on 470 consecutive forensic cases, was to ascertain the advantages of the sum value to estimate antemortem blood glucose concentrations and, consequently, to rule out fatal diabetic ketoacidosis as the cause of death. Other biochemical parameters, such as blood 3-beta-hydroxybutyrate, acetoacetate, acetone, glycated haemoglobin and urine glucose levels, were also determined. In addition, postmortem native CT scan, autopsy, histology, neuropathology and toxicology were performed to confirm diabetic ketoacidosis as the cause of death. According to our results, the sum value does not add any further information for the estimation of antemortem blood glucose concentration. The vitreous glucose concentration appears to be the most reliable marker to estimate antemortem hyperglycaemia and, along with the determination of other biochemical markers (such as blood acetone and 3-beta-hydroxybutyrate, urine glucose and glycated haemoglobin), to confirm diabetic ketoacidosis as the cause of death.

  8. Oxaloacetate- and acetoacetate-induced calcium efflux from mitochondria occurs by reversal of the uptake pathway.

    PubMed Central

    Bardsley, M E; Brand, M D

    1982-01-01

    1. Addition of oxaloacetate or acetoacetate to isolated rat liver mitochondria results in an efflux of Ca2+. Concomitant with this efflux is an immediate oxidation of endogenous nicotinamide nucleotides, a fall in the mitochondrial membrane potential and an increase in the rate of respiration. The primary effect in this sequence may be either (a) physiologically important stimulation of a Ca2+-efflux carrier, followed by Ca2+ re-uptake, a fall in membrane potential and increased respiration, or (b) physiologically unimportant damage to mitochondrial integrity, followed by a fall in membrane potential, increased respiration and Ca2+ efflux. 2. Ruthenium Red and EGTA will restore the increased respiratory rate to one approximating to the control rate of respiration. However, addition of lanthanide, at a concentration which inhibits the uptake but not the normal efflux of Ca2+, inhibits the rate of Ca2+ efflux induced by oxaloacetate or acetoacetate. Therefore the observed efflux is occurring by a reversal of the uptake pathway (uniporter) and thus follows the fall in membrane potential. 3. From these results we conclude that the decrease in membrane potential and increase in the rate of respiration seen during oxaloacetate- or acetoacetate-induced Ca2+ efflux cannot be accounted for by rapid Ca2+ cycling, but are due to damage to mitochondrial integrity. PMID:7082307

  9. Tricaprylin Alone Increases Plasma Ketone Response More Than Coconut Oil or Other Medium-Chain Triglycerides: An Acute Crossover Study in Healthy Adults

    PubMed Central

    Vandenberghe, Camille; St-Pierre, Valérie; Pierotti, Tyler; Fortier, Mélanie; Castellano, Christian-Alexandre; Cunnane, Stephen C

    2017-01-01

    Abstract Background: Ketones are the brain's main alternative fuel to glucose. Dietary medium-chain triglyceride (MCT) supplements increase plasma ketones, but their ketogenic efficacy relative to coconut oil (CO) is not clear. Objective: The aim was to compare the acute ketogenic effects of the following test oils in healthy adults: coconut oil [CO; 3% tricaprylin (C8), 5% tricaprin (C10)], classical MCT oil (C8-C10; 55% C8, 35% C10), C8 (>95% C8), C10 (>95% C10), or CO mixed 50:50 with C8-C10 or C8. Methods: In a crossover design, 9 participants with mean ± SD ages 34 ± 12 y received two 20-mL doses of the test oils prepared as an emulsion in 250 mL lactose-free skim milk. During the control (CTL) test, participants received only the milk vehicle. The first test dose was taken with breakfast and the second was taken at noon but without lunch. Blood was sampled every 30 min over 8 h for plasma acetoacetate and β-hydroxybutyrate (β-HB) analysis. Results: C8 was the most ketogenic test oil with a day-long mean ± SEM of +295 ± 155 µmol/L above the CTL. C8 alone induced the highest plasma ketones expressed as the areas under the curve (AUCs) for 0–4 and 4–8 h (780 ± 426 µmol ⋅ h/L and 1876 ± 772 µmol ⋅ h/L, respectively); these values were 813% and 870% higher than CTL values (P < 0.01). CO plasma ketones peaked at +200 µmol/L, or 25% of the C8 ketone peak. The acetoacetate-to-β-HB ratio increased 56% more after CO than after C8 after both doses. Conclusions: In healthy adults, C8 alone had the highest net ketogenic effect over 8 h, but induced only half the increase in the acetoacetate-to-β-HB ratio compared with CO. Optimizing the type of MCT may help in developing ketogenic supplements designed to counteract deteriorating brain glucose uptake associated with aging. This trial was registered at clinicaltrials.gov as NCT 02679222.

  10. Anti-Diabetic Activity and Metabolic Changes Induced by Andrographis paniculata Plant Extract in Obese Diabetic Rats.

    PubMed

    Akhtar, Muhammad Tayyab; Bin Mohd Sarib, Mohamad Syakir; Ismail, Intan Safinar; Abas, Faridah; Ismail, Amin; Lajis, Nordin Hj; Shaari, Khozirah

    2016-08-09

    Andrographis paniculata is an annual herb and widely cultivated in Southeast Asian countries for its medicinal use. In recent investigations, A. paniculata was found to be effective against Type 1 diabetes mellitus (Type 1 DM). Here, we used a non-genetic out-bred Sprague-Dawley rat model to test the antidiabetic activity of A. paniculata against Type 2 diabetes mellitus (Type 2 DM). Proton Nuclear Magnetic Resonance (¹H-NMR) spectroscopy in combination with multivariate data analyses was used to evaluate the A. paniculata and metformin induced metabolic effects on the obese and obese-diabetic (obdb) rat models. Compared to the normal rats, high levels of creatinine, lactate, and allantoin were found in the urine of obese rats, whereas, obese-diabetic rats were marked by high glucose, choline and taurine levels, and low lactate, formate, creatinine, citrate, 2-oxoglutarate, succinate, dimethylamine, acetoacetate, acetate, allantoin and hippurate levels. Treatment of A. paniculata leaf water extract was found to be quite effective in restoring the disturbed metabolic profile of obdb rats back towards normal conditions. Thisstudy shows the anti-diabetic potential of A. paniculata plant extract and strengthens the idea of using this plant against the diabetes. Further classical genetic methods and state of the art molecular techniques could provide insights into the molecular mechanisms involved in the pathogenesis of diabetes mellitus and anti-diabetic effects of A. paniculata water extract.

  11. High-performance liquid chromatography determination of ketone bodies in human plasma by precolumn derivatization with p-nitrobenzene diazonium fluoroborate.

    PubMed

    Yamato, Susumu; Shinohara, Kumiko; Nakagawa, Saori; Kubota, Ai; Inamura, Katsushi; Watanabe, Gen; Hirayama, Satoshi; Miida, Takashi; Ohta, Shin

    2009-01-01

    We developed and validated a sensitive and convenient high-performance liquid chromatography (HPLC) method for the specific determination of ketone bodies (acetoacetate and D-3-hydroxybutyrate) in human plasma. p-Nitrobenzene diazonium fluoroborate (diazo reagent) was used as a precolumn derivatization agent, and 3-(2-hydroxyphenyl) propionic acid was used as an internal standard. After the reaction, excess diazo reagent and plasma proteins were removed by passing through a solid-phase cartridge (C(18)). The derivatives retained on the cartridge were eluted with methanol, introduced into the HPLC system, and then detected with UV at 380 nm. A calibration curve for acetoacetate standard solution with a 20-microl injection volume showed good linearity in the range of 1 to 400 microM with a 0.9997 correlation coefficient. For the determination of D-3-hydroxybutyrate, it was converted to acetoacetate before reaction with the diazo reagent by an enzymatic coupling method using D-3-hydroxybutyrate dehydrogenase and lactate dehydrogenase. A calibration curve for D-3-hydroxybutyrate standard solution also showed good linearity in the range of 1.5 to 2000 microM with a 0.9988 correlation coefficient. Analytical recoveries of acetoacetate and D-3-hydroxybutyrate in human plasma were satisfactory. The method was successfully applied to samples from diabetic patients, and results were consistent with those obtained using the thio-NAD enzymatic cycling method used in clinical laboratories.

  12. Fisher Discrimination of Metabolic Changes in Rats Treated with Aspirin and Ibuprofen.

    PubMed

    Zhang, Jing; Song, Huanchun; Jiang, Shuying; Chen, Zhibin; Tong, Shuhua; Lin, Feiyan; Wen, Congcong; Zhang, Xiuhua; Hu, Lufeng

    2017-01-01

    Aspirin and ibuprofen are the most frequently prescribed non-steroidal anti-inflammatory drugs in the world. However, both are associated with a variety of toxicities. We applied serum metabonomics and Fisher discrimination for the early diagnosis of its toxic reaction in order to help diagnose these toxicities. A total of 45 rats were randomly divided into Control group, Aspirin group, and Ibuprofen groups. The experiment groups were given intragastric aspirin (15 mg/kg) or ibuprofen (15 mg/kg) for 3 weeks. Liver function tests were performed and blood metabonomics were analyzed by gas chromatography-mass spectrometry. The most important compounds altered were trihydroxybutyric acid and l-alanine in the aspirin group, and acetoacetic acid, l-alanine, and trihydroxybutyric acid in the ibuprofen group. With respect to metabolic profiles, all 3 groups were completely distinct from one another. Fisher discrimination showed that 91.1% of the original grouped cases were correctly classified by the third week. However, only 55.6% of liver function tests were able to classify grouped cases correctly. Trihydroxybutyric acid, l-alanine, and acetoacetic acid were the most significant indicators of altered serum metabolites following intragastric administration of aspirin and ibuprofen in rates. These metabolomic data may be used for classification of aspirin and ibuprofen toxicity. © 2017 S. Karger AG, Basel.

  13. Chiral Compounds and Green Chemistry in Undergraduate Organic Laboratories: Reduction of a Ketone by Sodium Borohydride and Baker's Yeast

    NASA Astrophysics Data System (ADS)

    Pohl, Nicola; Clague, Allen; Schwarz, Kimberly

    2002-06-01

    We describe an integrated set of experiments for the undergraduate organic laboratory that allows students to compare and contrast biological and chemical means of introducing chirality into a molecule. The racemic reduction of ethyl acetoacetate with sodium borohydride and the same reduction in the presence of a tartaric acid ligand are described, and a capillary gas chromatography column packed with a chiral material for product analysis is introduced. The results of these two hydride reactions are compared with the results of a common undergraduate experiment, the baker's yeast reduction of ethyl acetoacetate.

  14. A new irreversible enzyme-aided esterification method in organic solvents.

    PubMed

    Jeromin, Günter E; Zoor, Annegreth

    2008-05-01

    A new irreversible esterification method for carboxylic acids catalyzed by a lipase from Candida antarctica (Novozyme 435) in organic solvents has been developed. The water produced during the process is chemically destroyed by a corresponding ester of acetoacetate, which acts as a sacrificial substrate in this reaction. The flavour esters isobutyl acetate, methyl butyrate, ethyl butyrate and benzyl butyrate were synthesized either in small scale (0.05 mol) or large scale (1 mol). The yields range from 82 to 92% within 24 h at 52 degrees C. Optimal molar ratios of reactants were 1:1:1 (carboxylic acid:alcohol:acetoacetate).

  15. Cyclization of arylacetoacetates to indene and dihydronaphthalene derivatives in strong acids. Evidence for involvement of further protonation of O,O-diprotonated beta-ketoester, leading to enhancement of cyclization.

    PubMed

    Kurouchi, Hiroaki; Sugimoto, Hiromichi; Otani, Yuko; Ohwada, Tomohiko

    2010-01-20

    The chemical features, such as substrate stability, product distribution, and substrate generality, and the reaction mechanism of Brønsted superacid-catalyzed cyclization reactions of aromatic ring-containing acetoacetates (beta-ketoesters) were examined in detail. While two types of carbonyl cyclization are possible, i.e., keto cyclization and ester cyclization, the former was found to take place exclusively. The reaction constitutes an efficient method to synthesize indene and 3,4-dihydronapthalene derivatives. Acid-base titration monitored with (13)C NMR spectroscopy showed that the acetoacetates are fully O(1),O(3)-diprotonated at H(0) = -11. While the five-membered ring cyclization of the arylacetoacetates proceeded slowly at H(0) = -11, a linear increase in the rate of the cyclization was found with increasing acidity in the high acidity region of H(0) = -11.8 to -13.3. Therefore, the O(1),O(3)-diprotonated acetoacetates exhibited some cyclizing reactivity, but they are not the reactive intermediates responsible for the acceleration of the cyclization in the high acidity region. The reactive cationic species might be formed by further protonation (or protosolvation) of the O(1),O(3)-diprotonated acetoacetates; i.e., they may be tricationic species. Thermochemical data on the acid-catalyzed cyclization of the arylacetoacetates showed that the activation energy is decreased significantly as compared with that of the related acid-catalyzed cyclization reaction of a compound bearing a single functional group, such as a ketone. These findings indicate that intervention of the trication contributes to the activation of the cyclization of arylacetoacetates in strong acid, and the electron-withdrawing nature of the O-protonated ester functionality significantly increases the electrophilicity of the ketone moiety.

  16. Catecholamines - urine

    MedlinePlus

    Dopamine - urine test; Epinephrine - urine test; Adrenalin - urine test; Urine metanephrine; Normetanephrine; Norepinephrine - urine test; Urine catecholamines; VMA; HVA; Metanephrine; Homovanillic ...

  17. Proteomic analysis of nitrate-dependent acetone degradation by Alicycliphilus denitrificans strain BC.

    PubMed

    Oosterkamp, Margreet J; Boeren, Sjef; Atashgahi, Siavash; Plugge, Caroline M; Schaap, Peter J; Stams, Alfons J M

    2015-06-01

    Alicycliphilus denitrificans strain BC grows anaerobically on acetone with nitrate as electron acceptor. Comparative proteomics of cultures of A. denitrificans strain BC grown on either acetone or acetate with nitrate was performed to study the enzymes involved in the acetone degradation pathway. In the proposed acetone degradation pathway, an acetone carboxylase converts acetone to acetoacetate, an AMP-dependent synthetase/ligase converts acetoacetate to acetoacetyl-CoA, and an acetyl-CoA acetyltransferase cleaves acetoacetyl-CoA to two acetyl-CoA. We also found a putative aldehyde dehydrogenase associated with acetone degradation. This enzyme functioned as a β-hydroxybutyrate dehydrogenase catalyzing the conversion of surplus acetoacetate to β-hydroxybutyrate that may be converted to the energy and carbon storage compound, poly-β-hydroxybutyrate. Accordingly, we confirmed the formation of poly-β-hydroxybutyrate in acetone-grown cells of strain BC. Our findings provide insight in nitrate-dependent acetone degradation that is activated by carboxylation of acetone. This will aid studies of similar pathways found in other microorganisms degrading acetone with nitrate or sulfate as electron acceptor. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Acetoacetate promotes the formation of fluorescent advanced glycation end products (AGEs).

    PubMed

    Bohlooli, Mousa; Ghaffari-Moghaddam, Mansour; Khajeh, Mostafa; Aghashiri, Zohre; Sheibani, Nader; Moosavi-Movahedi, Ali Akbar

    2016-12-01

    Acetoacetate (AA) is an important ketone body, which produces reactive oxygen species (ROS). Advanced glycation end products (AGEs) are defined as final products of glycation process whose production is influenced by the levels of ROS. The accumulation of AGEs in the body contributes to pathogenesis of many diseases including complications of diabetes, and Alzheimer's and Parkinson's disease. Here, we evaluated the impact of AA on production of AGEs upon incubation of human serum albumin (HSA) with glucose. The effect of AA on the AGEs formation of HSA was studied under physiological conditions after incubation with glucose for 35 days. The physical techniques including circular dichroism (CD) and fluorescence spectroscopy were used to assess the impact of AA on formation and structural changes of glycated HSA (GHSA). Our results indicated that the secondary and tertiary structural changes of GHSA were increased in the presence of AA. The fluorescence intensity measurements of AGEs also showed an increase in AGEs formation. Acetoacetate has an activator effect in formation of AGEs through ROS production. The presence of AA may result in enhanced glycation in the presence of glucose and severity of complications associated with accumulation of AGEs.

  19. Myoglobin urine test

    MedlinePlus

    Urine myoglobin; Heart attack - myoglobin urine test; Myositis - myoglobin urine test; Rhabdomyolysis - myoglobin urine test ... The test involves only normal urination, which should cause no discomfort.

  20. Ketones urine test

    MedlinePlus

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  1. Urinalysis: MedlinePlus Health Topic

    MedlinePlus

    ... Urine odor (Medical Encyclopedia) Also in Spanish Urine pH test (Medical Encyclopedia) Also in Spanish Urine specific gravity ... Urine - abnormal color Urine - bloody Urine odor Urine pH test Urine specific gravity test Show More Show Less ...

  2. Urine chemistry

    MedlinePlus

    ... rate 24-hour urine protein Acid loading test (pH) Adrenalin - urine test Amylase - urine Bilirubin - urine Calcium - urine Citric acid ... Urine dermatan sulfate Urine - hemoglobin Urine metanephrine Urine pH Urine specific gravity Vanillylmandelic acid (VMA)

  3. Decreased carbon shunting from glucose towards oxidative metabolism in diet-induced ketotic rat brain

    PubMed Central

    Zhang, Yifan; Zhang, Shenghui; Marin-Valencia, Isaac; Puchowicz, Michelle A.

    2014-01-01

    The mechanistic link of ketosis to neuroprotection under certain pathological conditions continues to be explored. We investigated whether chronic ketosis induced by ketogenic diet results in the partitioning of ketone bodies towards oxidative metabolism in brain. We hypothesized that diet-induced ketosis results in increased shunting of ketone bodies towards citric acid cycle (CAC) and amino acids with decreased carbon shunting from glucose. Rats were fed standard (STD) or ketogenic (KG) diets for 3.5 weeks and then infused with [U-13C]glucose or [U-13C]acetoacetate tracers. Concentrations and 13C-labeling pattern of CAC intermediates and amino acids were analyzed from brain homogenates using stable isotopomer mass spectrometry analysis. The contribution of [U-13C]glucose to acetyl-CoA and amino acids decreased by ~30% in the KG group vs STD, whereas [U-13C]acetoacetate contributions were more than 2-fold higher. The concentration of GABA remained constant across all groups; however, the 13C-labeling of GABA was markedly increased in the KG group infused with [U-13C]acetoacetate compared to STD. This study reveals that there is a significant contribution of ketone bodies to oxidative metabolism and GABA in diet-induced ketosis. We propose that this represents a fundamental mechanism of neuroprotection under pathological conditions. PMID:25314677

  4. The redox state of endogenous pyridine nucleotides can determine both the degree of mitochondrial oxidative stress and the solute selectivity of the permeability transition pore.

    PubMed

    Zago, E B; Castilho, R F; Vercesi, A E

    2000-07-28

    Acetoacetate, an NADH oxidant, stimulated the ruthenium red-insensitive rat liver mitochondrial Ca(2+) efflux without significant release of state-4 respiration, disruption of membrane potential (Deltapsi) or mitochondrial swelling. This process is compatible with the opening of the currently designated low conductance state of the permeability transition pore (PTP) and, under our experimental conditions, was associated with a partial oxidation of the mitochondrial pyridine nucleotides. In contrast, diamide, a thiol oxidant, induced a fast mitochondrial Ca(2+) efflux associated with a release of state-4 respiration, a disruption of Deltapsi and a large amplitude mitochondrial swelling. This is compatible with the opening of the high conductance state of the PTP and was associated with extensive oxidation of pyridine nucleotides. Interestingly, the addition of carbonyl cyanide p-(trifluoromethoxy)phenylhydrazone to the acetoacetate experiment promoted a fast shift from the low to the high conductance state of the PTP. Both acetoacetate and diamide-induced mitochondrial permeabilization were inhibited by exogenous catalase. We propose that the shift from a low to a high conductance state of the PTP can be promoted by the oxidation of NADPH. This impairs the antioxidant function of the glutathione reductase/peroxidase system, strongly strengthening the state of mitochondrial oxidative stress.

  5. Beta-ketothiolase deficiency: An unusual cause of recurrent ketoacidosis.

    PubMed

    Kılıç-Yıldırım, Gonca; Durmuş-Aydoğdu, Sultan; Ceylaner, Serdar; Sass, Jörn Oliver

    2017-01-01

    Kılıç-Yıldırım G, Durmuş-Aydoğdu S, Ceylaner S, Sass JO. Beta-ketothiolase deficiency: An unusual cause of recurrent ketoacidosis. Turk J Pediatr 2017; 59: 471-474. Beta-ketothiolase deficiency (mitochondrial acetoacetyl-CoA thiolase, MAT or T2 deficiency) is a rare autosomal recessive disorder of isoleucine and ketone body metabolism due to acetyl-CoA acetyltransferase-1 (ACAT1) gene mutations. The disease is characterized by recurrent episodes of ketoasidosis which starts with vomiting and followed by dehydration and tachypnea. Here, we present a patient who was admitted to the hospital with severe acidosis and dehydration because of vomiting induced by protein rich nutrient and was diagnosed with MAT deficiency. 3-hydroxy-butyric acid, acetoacetic acid and 3-hydroxy-iso-valeric acid levels were significantly increased and tiglyglycine as trace amount in the urine organic acid analysis of the patient. Genetic analysis for ACAT-1 showed compound heterozygosity for the mutations c.949G > A (p.D317N) and c.951C > T (p.D317D), which both are known to cause exon 10 skipping and to be pathogenic missense mutations.

  6. HCG in urine

    MedlinePlus

    Beta-HCG - urine; Human chorionic gonadotropin - urine; Pregnancy test - hCG in urine ... To collect a urine sample, you urinate into a special (sterile) cup. Home pregnancy tests require the test strip to be dipped into ...

  7. [Comparison of essential oil enriched with ultrafiltration method and extraction method respectively from essential oil-in-water emulsion of Citri Reticulatae Pericarpium Viride by GC-MS].

    PubMed

    Yin, Ailing; Han, Zhifeng; Shen, Jie; Guo, Liwei; Cao, Guiping

    2011-10-01

    To study on the separation from essential oil-in-water emulsion of Citri Reticulatae Pericarpium Viride by ultrafiltration and acetoacetate extraction methods respectively, and the comparison of the oil yields and chemical compositions. Essential oil-in-water emulsion of Citri Reticulatae Pericarpium Viride was separated by ultrafiltration and acetoacetate extraction methods respectively, and the chemical compositions were analyzed and compared by GC-MS. Ultrafiltration method could enrich essential oil more and its chemical compositions were more similar to the essential oil prepared by steam distillation method. Ultrafiltration method is a good medium to separate essential oil from essential oil-in-water emulsion of Citri Reticulatae Pericarpium Viride.

  8. Glucose urine test

    MedlinePlus

    Urine sugar test; Urine glucose test; Glucosuria test; Glycosuria test ... After you provide a urine sample, it is tested right away. The health care provider uses a dipstick made with a color-sensitive pad. The ...

  9. Does Performing Preplacement Workplace Hair Drug Testing Influence US Department of Transportation Random and Postaccident Urine Drug Test Positivity Rates?

    PubMed

    Price, James W

    Does performing pre-employment hair drug testing subsequently affect the prevalence of positive random and postaccident urine drug tests? This cross-sectional study was designed to evaluate the prevalence of positive postaccident and random workplace urine drug tests for companies that perform pre-employment hair and urine drug testing to companies that only perform pre-employment urine drug testing. Fisher exact test of independence indicated no significant difference between pre-employment hair drug testing and overall US Department of Transportation random and postaccident urine drug test positivity rates. The analysis failed to reject the null hypothesis, suggesting that pre-employment hair drug testing had no effect upon random and postaccident urine drug test positivity rates.

  10. Urine melanin test

    MedlinePlus

    Thormahlen's test; Melanin - urine ... A clean-catch urine sample is needed. ... this substance that it shows up in the urine. ... Normally, melanin is not present in urine. Normal value ranges may ... measurements or test different samples. Talk to your health ...

  11. Effects of polychlorinated biphenyls and nutritional restriction on barbituate-induced sleeping times and selected blood characteristics in raccoons (Procyon lotor)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montz, W.E.; Card, W.C.; Kirkpatrick, R.L.

    1982-05-01

    Hepatic microsomal enzyme activity was induced in wild-trapped raccoons (Procyon lotor) and selected blood characteristics were measured in an effort to detect responses due to PCB ingestion, nutritional restriction, and their interactions. Barbiturate-induced sleeping times were used as an index of hepatic microsomal activity because they have been used reliably by other workers. Blood characteristics examined in the study were nonesterified fatty acids (NEFA), cholesterol, and three ketone bodies (D-(-)-3-hydroxybutyrate, acetoacetate, and acetone). Results show a reduction in sleeping times, elevated NEFA and D-(-)-3-hydroxybutyrate concentrations, and lower cholesterol concentrations in PCB-treated groups. A highly significant interaction between PCB treatment andmore » nutritional restriction was observed in acetoacetate concentrations. (JMT)« less

  12. Calcium in Urine Test: MedlinePlus Lab Test Information

    MedlinePlus

    ... medlineplus.gov/labtests/calciuminurinetest.html Calcium in Urine Test To use the sharing features on this page, ... enable JavaScript. What is a Calcium in Urine Test? A calcium in urine test measures the amount ...

  13. Rapid spot tests for detecting the presence of adulterants in urine specimens submitted for drug testing.

    PubMed

    Dasgupta, Amitava; Wahed, Amer; Wells, Alice

    2002-02-01

    Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite, and "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity checks (pH, specific gravity, and temperature). We developed rapid spot tests for detecting these adulterants in urine. Addition of 3% hydrogen peroxide in urine adulterated with PCC caused rapid formation of a dark brown color. In contrast, unadulterated urine turned colorless when hydrogen peroxide was added. When urine contaminated with nitrite and 2 to 3 drops of 2N hydrochloric acid were added to 2% aqueous potassium permanganate solution, the dark pink permanganate solution turned colorless immediately with effervescence. Urine contaminated with nitrite liberated iodine from potassium iodide solution in the presence of 2N hydrochloric acid. Urine adulterated with PCC also liberated iodine from potassium iodide in acid medium but did not turn potassium permanganate solution colorless. Urine specimens from volunteers and random urine samples that tested negative for drugs did not cause false-positive results. These rapid spot tests are useful for detecting adulterated urine to avoid false-negative drug tests.

  14. Blister Test for Measurements of Adhesion and Adhesion Degradation of Organic Polymers on AA2024-T3

    NASA Astrophysics Data System (ADS)

    Rincon Troconis, Brendy Carolina

    A key parameter for the performance of corrosion protective coatings applied to metals is adhesion. Surface preparation prior to coating application is known to be critical, but there is a lack of understanding of what controls adhesion. Numerous techniques have been developed in the last decades to measure the adhesion strength of coatings to metals. Nonetheless, they are generally non-quantitative, non-reproducible, performed in dry conditions, or overestimate adhesion. In this study, a quantitative and reproducible technique, the Blister Test (BT), is used. The BT offers the ability to study the effects of a range of parameters, including the presence or absence of a wetting liquid, and simulates the stress situation in the coating/substrate interface. The effects of roughness and surface topography were studied by the BT and Optical Profilometry, using AA2024-T3 substrates coated with polyvinyl butyral (PVB). Random abrasion generated a surface with lower average roughness than aligned abrasion due to the continual cross abrasion of the grooves. The BT could discern the effects of different mechanical treatments. An adhesion strength indicator was defined and found to be a useful parameter. The effectiveness of standard adhesion techniques such as ASTM D4541 (Pull-off Test) and ASTM D3359 (Tape Test) was compared to the BT. Also, different attempts to measure adhesion and adhesion degradation of organic polymers to AA2024-T3 were tested. The pull-off test does not produce adhesive failure across the entire interface, while the tape test is a very qualitative technique and does not discern between the effects of different coating systems on the adhesion performance. The BT produces adhesive failure of the primer studied, is very reproducible, and is able to rank different coating systems. Therefore, it was found to be superior to the others. The approaches tested for adhesion degradation were not aggressive enough to have a measurable effect. The effects of cleaning/desmutting and conversion coating (CC) on the adhesion strength of acetoacetate to AA2024-T3 and the effects of improper water rinse temperature after cleaner were assessed using the BT. The results showed that pretreatments improve the adhesion strength of acetoacetate primer on AA2024-T3, but the comparative behavior depends on the specific treatment. Process control is of paramount importance for the performance of acetoacetate coated systems applied on AA2024-T3. The lack of thermal activity in the water rinse after cleaning step produces deleterious effects on the adhesion and blistering resistance of CC. Finally, a test sample incorporating a coated and scribed Al alloy panel and uncoated through-hole fasteners (Ti, SS316, AA2024-T3) was designed to provide accelerated response during atmospheric corrosion testing in the field (long-term beach exposure) or in laboratory chambers (ASTM B117). The results after only three weeks of exposure to ASTM B117 correlated well with long-term beach exposure, allowing rapid ranking of different coating systems. Of the fastener materials studied, visual observation and volume lost determination indicated that the worst attack occurred near SS316 fasteners its effect was explained by Scanning Kelvin Probe measurements and the available cathodic current measured in chloride solution.

  15. The reliability and validity of using the urine dipstick test by patient self-assessment for urinary tract infection screening in spinal cord injury patients.

    PubMed

    Duanngai, Krit; Sirasaporn, Patpiya; Ngaosinchai, Siriwan Surapaitoon

    2017-01-01

    The aim of this is to evaluate the reliability of the urine dipstick test by patients' self-assessment for urinary tract infection (UTI) screening and to determine the validity of urine dipstick test. Rehabilitation Department, Srinagarind Hospital, Thailand. A diagnostic study. This study compared the urine dipstick test (index test) with the National Institute on Disability and Rehabilitation Research (NIDRR) criteria (gold standard test) in spinal cord injury (SCI) patients. The urine dipstick test informed positive and negative results. Besides the NIDRR criteria classified as UTI and no UTI. The interrater reliability was measured in the sense of Kappa whereas the validity of urine dipstick test was reported in terms of sensitivity, specificity, positive likelihood ratio (LR) (+LR), negative LR (-LR), positive predictive value (PPV), and negative predictive value (NPV). Out of the 56 participants, the kappa of urine dipstick test for leukocyte esterase, nitrite, and combined leukocyte esterase and nitrite were 0.09, 0.21, and 0.52, respectively. The nitrite urine dipstick test showed the highest sensitivity (90%). The combined leukocyte esterase and nitrite urine dipstick test gave the highest specificity (87%), PPV (60%), NPV (93%), and +LR (5.63). The interrater reliability of combined leukocyte esterase and nitrite urine dipstick test was moderate agreement. The combined leukocyte esterase and nitrite urine dipstick test showed high level of both sensitivity and specificity. The combined leukocyte esterase and nitrite urine dipstick test should be promoted for patients' self-assessment for UTI screening in SCI patients.

  16. Carbonylation as a Key Reaction in Anaerobic Acetone Activation by Desulfococcus biacutus

    PubMed Central

    Gutiérrez Acosta, Olga B.; Hardt, Norman

    2013-01-01

    Acetone is activated by aerobic and nitrate-reducing bacteria via an ATP-dependent carboxylation reaction to form acetoacetate as the first reaction product. In the activation of acetone by sulfate-reducing bacteria, acetoacetate has not been found to be an intermediate. Here, we present evidence of a carbonylation reaction as the initial step in the activation of acetone by the strictly anaerobic sulfate reducer Desulfococcus biacutus. In cell suspension experiments, CO was found to be a far better cosubstrate for acetone activation than CO2. The hypothetical reaction product, acetoacetaldehyde, is extremely reactive and could not be identified as a free intermediate. However, acetoacetaldehyde dinitrophenylhydrazone was detected by mass spectrometry in cell extract experiments as a reaction product of acetone, CO, and dinitrophenylhydrazine. In a similar assay, 2-amino-4-methylpyrimidine was formed as the product of a reaction between acetoacetaldehyde and guanidine. The reaction depended on ATP as a cosubstrate. Moreover, the specific activity of aldehyde dehydrogenase (coenzyme A [CoA] acylating) tested with the putative physiological substrate was found to be 153 ± 36 mU mg−1 protein, and its activity was specifically induced in extracts of acetone-grown cells. Moreover, acetoacetyl-CoA was detected (by mass spectrometry) after the carbonylation reaction as the subsequent intermediate after acetoacetaldehyde was formed. These results together provide evidence that acetoacetaldehyde is an intermediate in the activation of acetone by sulfate-reducing bacteria. PMID:23913429

  17. Carbonylation as a key reaction in anaerobic acetone activation by Desulfococcus biacutus.

    PubMed

    Gutiérrez Acosta, Olga B; Hardt, Norman; Schink, Bernhard

    2013-10-01

    Acetone is activated by aerobic and nitrate-reducing bacteria via an ATP-dependent carboxylation reaction to form acetoacetate as the first reaction product. In the activation of acetone by sulfate-reducing bacteria, acetoacetate has not been found to be an intermediate. Here, we present evidence of a carbonylation reaction as the initial step in the activation of acetone by the strictly anaerobic sulfate reducer Desulfococcus biacutus. In cell suspension experiments, CO was found to be a far better cosubstrate for acetone activation than CO2. The hypothetical reaction product, acetoacetaldehyde, is extremely reactive and could not be identified as a free intermediate. However, acetoacetaldehyde dinitrophenylhydrazone was detected by mass spectrometry in cell extract experiments as a reaction product of acetone, CO, and dinitrophenylhydrazine. In a similar assay, 2-amino-4-methylpyrimidine was formed as the product of a reaction between acetoacetaldehyde and guanidine. The reaction depended on ATP as a cosubstrate. Moreover, the specific activity of aldehyde dehydrogenase (coenzyme A [CoA] acylating) tested with the putative physiological substrate was found to be 153 ± 36 mU mg(-1) protein, and its activity was specifically induced in extracts of acetone-grown cells. Moreover, acetoacetyl-CoA was detected (by mass spectrometry) after the carbonylation reaction as the subsequent intermediate after acetoacetaldehyde was formed. These results together provide evidence that acetoacetaldehyde is an intermediate in the activation of acetone by sulfate-reducing bacteria.

  18. Adulterants in Urine Drug Testing.

    PubMed

    Fu, S

    Urine drug testing plays an important role in monitoring licit and illicit drug use for both medico-legal and clinical purposes. One of the major challenges of urine drug testing is adulteration, a practice involving manipulation of a urine specimen with chemical adulterants to produce a false negative test result. This problem is compounded by the number of easily obtained chemicals that can effectively adulterate a urine specimen. Common adulterants include some household chemicals such as hypochlorite bleach, laundry detergent, table salt, and toilet bowl cleaner and many commercial products such as UrinAid (glutaraldehyde), Stealth® (containing peroxidase and peroxide), Urine Luck (pyridinium chlorochromate, PCC), and Klear® (potassium nitrite) available through the Internet. These adulterants can invalidate a screening test result, a confirmatory test result, or both. To counteract urine adulteration, drug testing laboratories have developed a number of analytical methods to detect adulterants in a urine specimen. While these methods are useful in detecting urine adulteration when such activities are suspected, they do not reveal what types of drugs are being concealed. This is particularly the case when oxidizing urine adulterants are involved as these oxidants are capable of destroying drugs and their metabolites in urine, rendering the drug analytes undetectable by any testing technology. One promising approach to address this current limitation has been the use of unique oxidation products formed from reaction of drug analytes with oxidizing adulterants as markers for monitoring drug misuse and urine adulteration. This novel approach will ultimately improve the effectiveness of the current urine drug testing programs. © 2016 Elsevier Inc. All rights reserved.

  19. Porphyrins - urine test

    MedlinePlus

    Urine uroporphyrin; Urine coproporphyrin; Porphyria - uroporphyrin ... After you provide a urine sample, it is tested in the lab. This is called a random urine sample. If needed, your health care provider ...

  20. Crystals in Urine Test: MedlinePlus Lab Test Information

    MedlinePlus

    ... medlineplus.gov/labtests/crystalsinurinetest.html Crystals in Urine Test To use the sharing features on this page, ... enable JavaScript. What is a Crystals in Urine Test? Your urine contains many chemicals. Sometimes these chemicals ...

  1. Protein urine test

    MedlinePlus

    Urine protein; Albumin - urine; Urine albumin; Proteinuria; Albuminuria ... After you provide a urine sample, it is tested. The health care provider uses a dipstick made with a color-sensitive pad. The color change ...

  2. Swit_4259, an acetoacetate decarboxylase-like enzyme from Sphingomonas wittichii RW1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mydy, Lisa S.; Mashhadi, Zahra; Knight, T. William

    The Gram-negative bacteriumSphingomonas wittichiiRW1 is notable for its ability to metabolize a variety of aromatic hydrocarbons. Not surprisingly, theS. wittichiigenome contains a number of putative aromatic hydrocarbon-degrading gene clusters. One of these includes an enzyme of unknown function, Swit_4259, which belongs to the acetoacetate decarboxylase-like superfamily (ADCSF). Here, it is reported that Swit_4259 is a small (28.8 kDa) tetrameric ADCSF enzyme that, unlike the prototypical members of the superfamily, does not have acetoacetate decarboxylase activity. Structural characterization shows that the tertiary structure of Swit_4259 is nearly identical to that of the true decarboxylases, but there are important differences in themore » fine structure of the Swit_4259 active site that lead to a divergence in function. In addition, it is shown that while it is a poor substrate, Swit_4259 can catalyze the hydration of 2-oxo-hex-3-enedioate to yield 2-oxo-4-hydroxyhexanedioate. It is also demonstrated that Swit_4259 has pyruvate aldolase-dehydratase activity, a feature that is common to all of the family V ADCSF enzymes studied to date. The enzymatic activity, together with the genomic context, suggests that Swit_4259 may be a hydratase with a role in the metabolism of an as-yet-unknown hydrocarbon. These data have implications for engineering bioremediation pathways to degrade specific pollutants, as well as structure–function relationships within the ADCSF in general.« less

  3. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  4. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  5. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  6. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  7. Comparison of urine specimen collection times and testing fractions for the detection of high-risk human papillomavirus and high-grade cervical precancer.

    PubMed

    Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S

    2016-01-01

    Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. The diagnostic accuracy of the rapid dipstick test to predict asymptomatic urinary tract infection of pregnancy.

    PubMed

    Eigbefoh, J O; Isabu, P; Okpere, E; Abebe, J

    2008-07-01

    Untreated urinary tract infection can have devastating maternal and neonatal effects. Thus, routine screening for bacteriuria is advocated. This study was designed to evaluate the diagnostic accuracy of the rapid dipstick test to predict urinary tract infection in pregnancy with the gold standard of urine microscopy, culture and sensitivity acting as the control. The urine dipstick test uses the leucocyte esterase, nitrite and test for protein singly and in combination. The result of the dipstick was compared with the gold standard, urine microscopy, culture and sensitivity using confidence interval for proportions. The reliability and validity of the urine dipstick was also evaluated. Overall, the urine dipstick test has a poor correlation with urine culture (p = 0.125, CI 95%). The same holds true for individual components of the dipstick test. The overall sensitivity of the urine dipstick test was poor at 2.3%. Individual sensitivity of the various components varied between 9.1% for leucocyte esterase and the nitrite test to 56.8% for leucocyte esterase alone. The other components of the dipstick test, the test of nitrite, test for protein and combination of the test (leucocyte esterase, nitrite and proteinuria) appear to decrease the sensitivity of the leucocyte esterase test alone. The ability of the urine dipstick test to correctly rule out urinary tract infection (specificity) was high. The positive predictive value for the dipstick test was high, with the leucocyte esterase test having the highest positive predictive value compared with the other components of the dipstick test. The negative predictive value (NPV) was expectedly highest for the leucocyte esterase test alone with values higher than the other components of the urine dipstick test singly and in various combinations. Compared with the other parameters of the urine dipstick test, singly and in combination, leucocyte esterase appears to be the most accurate (90.25%). The dipstick test has a limited use in screening for asymptomatic bacteriuria. The leucocyte esterase test component of the dipstick test appears to have the highest reliability and validity. The other parameters of the dipstick test decreases the reliability and validity of the leucocyte esterase test. A positive test merits empirical antibiotics, while a negative test is an indication for urine culture. The urine dipstick test if positive will also be useful in follow-up of patient after treatment of urinary tract infection. This is useful in poor resource setting especially in the third world where there is a dearth of trained personnel and equipment for urine culture.

  9. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  10. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  11. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  12. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  13. Flow meter urine testing: a practical proposition in patients attending for urodynamics?

    PubMed

    Hashim, Hashim; Abrams, Paul

    2006-05-01

    To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.

  14. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  15. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  16. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  17. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  18. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  19. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    PubMed

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.

  20. Recommendations for provoked challenge urine testing.

    PubMed

    Ruha, Anne-Michelle

    2013-12-01

    "Urine mobilization test," "challenge test," and "provoked urine test" are all terms used to describe the administration of a chelating agent to a person prior to collection of their urine to test for metals. There is no standard, validated challenge test. Despite recommendations by professional and government organizations against the use of provoked urine testing, the tests are still commonly used and recommended by some practitioners. Challenge testing utilizes a variety of chelating agents, including dimercaptosuccinic acid (DMSA), dimercaptopropanesulfonate (DMPS), and ethylenediaminetetraacetic acid (EDTA). The agents are given by a variety of routes of administration, doses used are inconsistent, and urine collection procedures vary. Additional problems with challenge tests include comparison of results to inappropriate reference ranges and creatinine correction of urine obtained within hours of chelator administration. Human volunteer studies demonstrate that mercury is detected in the urine of most people even in the absence of known exposure or chelator administration, and that urinary mercury excretion rises after administration of a chelator, regardless of exposure history and in an unpredictable fashion. Studies also demonstrate that challenge testing fails to reveal a "body burden" of mercury due to remote exposure. Chelating agents have been associated with adverse reactions. Current evidence does not support the use of DMPS, DMSA, or other chelation challenge tests for the diagnosis of metal toxicity. Since there are no established reference ranges for provoked urine samples in healthy subjects, no reliable evidence to support a diagnostic value for the tests, and potential harm, these tests should not be utilized.

  1. Urine specimen validity test for drug abuse testing in workplace and court settings.

    PubMed

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  2. Impact of order set design on urine culturing practices at an academic medical centre emergency department.

    PubMed

    Munigala, Satish; Jackups, Ronald R; Poirier, Robert F; Liang, Stephen Y; Wood, Helen; Jafarzadeh, S Reza; Warren, David K

    2018-01-20

    Urinalysis and urine culture are commonly ordered tests in the emergency department (ED). We evaluated the impact of removal of order sets from the 'frequently ordered test' in the computerised physician order entry system (CPOE) on urine testing practices. We conducted a before (1 September to 20 October 2015) and after (21 October to 30 November 2015) study of ED patients. The intervention consisted of retaining 'urinalysis with reflex to microscopy' as the only urine test in a highly accessible list of frequently ordered tests in the CPOE system. All other urine tests required use of additional order screens via additional mouse clicks. The frequency of urine testing before and after the intervention was compared, adjusting for temporal trends. During the study period, 6499 (28.2%) of 22 948 ED patients had ≥1 urine test ordered. Urine testing rates for all ED patients decreased in the post intervention period for urinalysis (291.5 pre intervention vs 278.4 per 1000 ED visits post intervention, P=0.03), urine microscopy (196.5vs179.5, P=0.001) and urine culture (54.3vs29.7, P<0.001). When adjusted for temporal trends, the daily culture rate per 1000 ED visits decreased by 46.6% (-46.6%, 95% CI -66.2% to -15.6%), but urinalysis (0.4%, 95% CI -30.1 to 44.4%), microscopy (-6.5%, 95% CI -36.0% to 36.6%) and catheterised urine culture rates (17.9%, 95% CI -16.9 to 67.4) were unchanged. A simple intervention of retaining only 'urinalysis with reflex to microscopy' and removing all other urine tests from the 'frequently ordered' window of the ED electronic order set decreased urine cultures ordered by 46.6% after accounting for temporal trends. Given the injudicious use of antimicrobial therapy for asymptomatic bacteriuria, findings from our study suggest that proper design of electronic order sets plays a vital role in reducing excessive ordering of urine cultures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Enlarged prostate

    MedlinePlus

    ... gland. Other tests may include: Urine flow rate Post-void residual urine test to see how much urine is left in your bladder after you urinate Pressure-flow studies to measure the pressure in the bladder as ...

  4. Prevalence of isolated non-albumin proteinuria in the US population tested for both, urine total protein and urine albumin: An unexpected discovery.

    PubMed

    Katayev, Alexander; Zebelman, Arthur M; Sharp, Thomas M; Samantha Flynn; Bernstein, Richard K

    2017-04-01

    Isolated non-albumin proteinuria (NAP) is a condition when urine total protein concentrations are elevated without elevation of urine albumin. The prevalence of NAP in the US population tested for both, urine total protein and albumin was assessed in this study. The database of a US nationwide laboratory network was queried for test results when random urine albumin was ordered together with urine total protein and also when timed 24-hour urine albumin was ordered together with urine total protein. The total prevalence of NAP in the US population tested for both, urine total protein and albumin was calculated for patient groups having normal and low-normal urine albumin (random and timed) with elevated and severely increased urine total protein (random and timed). Also, the prevalence of NAP was calculated for patients with normal urine albumin to assess the probability of missing proteinuria if only urine albumin is measured. The prevalence of NAP in the random samples group was 10.1% (15.2% for females and 4.7% for males). Among patients with normal random albumin, there were 20.0% (27.3% of females and 10.7% of males) patients with NAP. The prevalence of NAP in the timed samples group was 24.6% (29.8% for females and 18.5% for males). Among patients with normal timed urine albumin, there were 36.2% (40.0% of females and 30.8% of males) patients with NAP. There was a strong positive association with female gender and NAP in most patients groups. Testing for only urine (micro)albumin can miss up to 40% of females and 30.8% of males with gross proteinuria. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. A pilot study to assess if urine specific gravity and urine colour charts are useful indicators of dehydration in acute stroke patients.

    PubMed

    Rowat, Anne; Smith, Laura; Graham, Cat; Lyle, Dawn; Horsburgh, Dorothy; Dennis, Martin

    2011-09-01

    The purpose of this pilot study was to examine whether urine specific gravity and urine colour could provide an early warning of dehydration in stroke patients compared with standard blood indicators of hydration status. Dehydration after stroke has been associated with increased blood viscosity, venous thrombo-embolism and stroke mortality at 3-months. Earlier identification of dehydration might allow us to intervene to prevent significant dehydration developing or reduce its duration to improve patient outcomes. We recruited 20 stroke patients in 2007 and measured their urine specific gravity with urine test strips, a refractometer, and urine colour of specimens taken daily on 10 consecutive days and compared with the routine blood urea:creatinine ratios over the same period to look for trends and relationships over time. The agreement between the refractometer, test strips and urine colour were expressed as a percentage with 95% confidence intervals. Nine (45%) of the 20 stroke patients had clinical signs of dehydration and had a significantly higher admission median urea:creatinine ratio (P = 0·02, Mann-Whitney U-test). There were no obvious relationships between urine specific gravity and urine colour with the urea:creatinine ratio. Of the 174 urine samples collected, the refractometer agreed with 70/174 (40%) urine test strip urine specific gravity and 117/174 (67%) urine colour measurements. Our results do not support the use of the urine test strip urine specific gravity as an early indicator of dehydration. Further research is required to develop a practical tool for the early detection of dehydration in stroke patients. © 2011 Blackwell Publishing Ltd.

  6. Urine testing and urinary tract infections in febrile infants seen in office settings: the Pediatric Research in Office Settings' Febrile Infant Study.

    PubMed

    Newman, Thomas B; Bernzweig, Jane A; Takayama, John I; Finch, Stacia A; Wasserman, Richard C; Pantell, Robert H

    2002-01-01

    To determine the predictors and results of urine testing of young febrile infants seen in office settings. Prospective cohort study. Offices of 573 pediatric practitioners from 219 practices in the American Academy of Pediatrics Pediatric Research in Office Settings' research network. A total of 3066 infants 3 months or younger with temperatures of 38 degrees C or higher were evaluated and treated according to the judgment of their practitioners. Urine testing results, early and late urinary tract infections (UTIs), and UTIs with bacteremia. Fifty-four percent of the infants initially had urine tested, of whom 10% had a UTI. The height of the fever was associated with urine testing and a UTI among those tested (adjusted odds ratio per degree Celsius, 2.2 for both). Younger age, ill appearance, and lack of a fever source were associated with urine testing but not with a UTI, whereas lack of circumcision (adjusted odds ratio, 11.6), female sex (adjusted odds ratio, 5.4), and longer duration of fever (adjusted odds ratio, 1.8 for fever lasting > or = 24 hours) were not associated with urine testing but were associated with a UTI. Bacteremia accompanied the UTI in 10% of the patients, including 17% of those younger than 1 month. Among 807 infants not initially tested or treated with antibiotics, only 2 had a subsequent documented UTI; both did well. Practitioners order urine tests selectively, focusing on younger and more ill-appearing infants and on those without an apparent fever source. Such selective urine testing, with close follow-up, was associated with few late UTIs in this large study. Urine testing should focus particularly on uncircumcised boys, girls, the youngest and sickest infants, and those with persistent fever.

  7. Comparison of spot tests with AdultaCheck 6 and Intect 7 urine test strips for detecting the presence of adulterants in urine specimens.

    PubMed

    Dasgupta, Amitava; Chughtai, Omar; Hannah, Christina; Davis, Bonnette; Wells, Alice

    2004-10-01

    Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite while "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity check (pH, specific gravity, creatinine and temperature). We previously reported the development of rapid spot tests to detect the presence of these adulterants. AdultaCheck 6 and Intect 7 urine test strips are commercially available for detecting the presence of these adulterants along with specific gravity, creatinine and pH in urine. The performance of these two test strips for detecting adulterants was compared with the results obtained by spot tests. Both AdultaCheck 6 and Intect 7 effectively detected the presence of nitrite and pyridinium chlorochromate in urine. Moreover, both test strips successfully detected the presence of glutaraldehyde, for which no spot test is currently available. High amount of glucose and ascorbic acid did not cause any false positive result with AdultaCheck 6 or Intect 7. Both AdultaCheck 6 and Intect 7 can be used for checking the integrity of a urine specimen submitted for drugs of abuse testing.

  8. Urine concentration test

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003608.htm Urine concentration test To use the sharing features on this page, please enable JavaScript. A urine concentration test measures the ability of the kidneys ...

  9. Urine specific gravity test

    MedlinePlus

    ... medlineplus.gov/ency/article/003587.htm Urine specific gravity test To use the sharing features on this page, please enable JavaScript. Urine specific gravity is a laboratory test that shows the concentration ...

  10. Validation of a urine circulating cathodic antigen cassette test for detection of Schistosoma haematobiumin uMkhanyakude district of South Africa.

    PubMed

    Rubaba, O; Chimbari, M J; Soko, W; Manyangadze, T; Mukaratirwa, S

    2018-06-01

    Circulating cathodic antigen (CCA) tests for schistosomiasis are fast and less complicated allowing making them good candidates for routine qualitative screening for schistosomiasis at point of care. The urine-CCA has been evaluated for detection of S. mansoni with promising results. Its specificity and consistency in detecting S. haematobium infection in different endemic regions has been variable. This study validated a rapid urine-CCA cassette test for qualitative detection of S. haematobium infection in an S. haematobium endemic area with low S. mansoni prevalence. Microscopic examination for the standard urine filtration technique was used to validate the commercially available urine-CCA cassette test (rapid medical diagnostics ® ). The validation was done in a sample of primary school pupils (n = 420) aged 10-15 years in schools in the Jozini Municipality, KZN. There was a relationship between infection intensity and a positive urine-CCA test. Using the urine filtration method as the gold standard, the prevalence for S. haematobium was 40%, the accuracy of the CCA kit was 54.8%, sensitivity was 68.1% while the specificity was 45.8%. The positive predictive value was 45.82% while the negative predictive value was 68.05%. Both the urine filtration and the urine-CCA methods detected heavy (≥50 eggs/10 mL urine) and light infections at statistically significant levels. The overall accuracy, sensitivity and specificity of the urine-CCA cassette test were low. The urine-CCA cassette test performed much better for heavy infections than low infections (p < 0.05) implying that the kit may not be suitable for low endemic areas. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Development testing of a shuttle urine collection system

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Flight tests conducted in December 1973 demonstrated the ability of an unisexual urine collection subsystem to function in a zero-g environment. The urinal, which could be adjusted with three degrees of freedom, accommodated 16 female test subjects with a wide range of stature, as well as five male test subjects. The urinal was in intimate contact with the female and was contoured to form an effective air seal at the periphery. When positioned 2-4 inches forward, the urinal could be used for male collection and contact was not required.

  12. A Prospective Blinded Evaluation of Urine-DNA Testing for Detection of Urothelial Bladder Carcinoma in Patients with Gross Hematuria.

    PubMed

    Dahmcke, Christina M; Steven, Kenneth E; Larsen, Louise K; Poulsen, Asger L; Abdul-Al, Ahmad; Dahl, Christina; Guldberg, Per

    2016-12-01

    Retrospective studies have provided proof of principle that bladder cancer can be detected by testing for the presence of tumor DNA in urine. We have conducted a prospective blinded study to determine whether a urine-based DNA test can replace flexible cystoscopy in the initial assessment of gross hematuria. A total of 475 consecutive patients underwent standard urological examination including flexible cystoscopy and computed tomography urography, and provided urine samples immediately before (n=461) and after (n=444) cystoscopy. Urine cells were collected using a filtration device and tested for eight DNA mutation and methylation biomarkers. Clinical evaluation identified 99 (20.8%) patients with urothelial bladder tumors. With this result as a reference and based on the analysis of all urine samples, the DNA test had a sensitivity of 97.0%, a specificity of 76.9%, a positive predictive value of 52.5%, and a negative predictive value of 99.0%. In three patients with a positive urine-DNA test without clinical evidence of cancer, a tumor was detected at repeat cystoscopy within 16 mo. Our results suggest that urine-DNA testing can be used to identify a large subgroup of patients with gross hematuria in whom cystoscopy is not required. We tested the possibility of using a urine-based DNA test to check for bladder cancer in patients with visible blood in the urine. Our results show that the test efficiently detects bladder cancer and therefore may be used to greatly reduce the number of patients who would need to undergo cystoscopy. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  13. An insight into the metabolic responses of ultra-small superparamagnetic particles of iron oxide using metabonomic analysis of biofluids

    NASA Astrophysics Data System (ADS)

    Feng, Jianghua; Liu, Huili; Zhang, Limin; Bhakoo, Kishore; Lu, Lehui

    2010-10-01

    Ultra-small superparamagnetic particles of iron oxides (USPIO) have been developed as intravenous organ/tissue-targeted contrast agents to improve magnetic resonance imaging (MRI) in vivo. However, their potential toxicity and effects on metabolism have attracted particular attention. In the present study, uncoated and dextran-coated USPIO were investigated by analyzing both rat urine and plasma metabonomes using high-resolution NMR-based metabonomic analysis in combination with multivariate statistical analysis. The wealth of information gathered on the metabolic profiles from rat urine and plasma has revealed subtle metabolic changes in response to USPIO administration. The metabolic changes include the elevation of urinary α-hydroxy-n-valerate, o- and p-HPA, PAG, nicotinate and hippurate accompanied by decreases in the levels of urinary α-ketoglutarate, succinate, citrate, N-methylnicotinamide, NAG, DMA, allantoin and acetate following USPIO administration. The changes associated with USPIO administration included a gradual increase in plasma glucose, N-acetyl glycoprotein, saturated fatty acid, citrate, succinate, acetate, GPC, ketone bodies (β-hydroxybutyrate, acetone and acetoacetate) and individual amino acids, such as phenylalanine, lysine, isoleucine, glycine, glutamine and glutamate and a gradual decrease of myo-inositol, unsaturated fatty acid and triacylglycerol. Hence USPIO administration effects are reflected in changes in a number of metabolic pathways including energy, lipid, glucose and amino acid metabolism. The size- and surface chemistry-dependent metabolic responses and possible toxicity were observed using NMR analysis of biofluids. These changes may be attributed to the disturbances of hepatic, renal and cardiac functions following USPIO administrations. The potential biotoxicity can be derived from metabonomic analysis and serum biochemistry analysis. Metabonomic strategy offers a promising approach for the detection of subtle physiological responses on mammalian metabolism, and can be employed to investigate the potential adverse effects of other nanoparticles and nanomaterials on the environment and human health.

  14. 24-hour urine copper test

    MedlinePlus

    ... medlineplus.gov/ency/article/003604.htm 24-hour urine copper test To use the sharing features on this page, please enable JavaScript. The 24-hour urine copper test measures the amount of copper in ...

  15. Medullary cystic kidney disease

    MedlinePlus

    ... Tests that may be done include: 24-hour urine volume and electrolytes Blood urea nitrogen (BUN) Complete blood count (CBC) Creatinine blood test Creatinine clearance -- blood and urine Uric acid blood test Urine specific gravity (will ...

  16. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    PubMed

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  17. Workplace drug testing in Italy: findings about second-stage testing.

    PubMed

    Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo

    2015-03-01

    Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Asymptomatic bacteriuria in pregnant women attending Boo-Ali Hospital Tehran Iran: Urine analysis vs. urine culture.

    PubMed

    Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana

    2017-11-01

    Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Of 123 urine samples, significant asymptomatic bacteriuria (≥10 4 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and specificity of 100%, whereas we can only refer the pregnant women with positive leucocyte esterase test and significant pyuria to the urine culture.

  19. Leukocyte esterase urine test

    MedlinePlus

    ... the urine. This may mean you have a urinary tract infection . If this test is positive, the urine should ... Results Mean An abnormal result indicates a possible urinary tract infection. The following may turn the test abnormal even ...

  20. Urobilinogen in Urine

    MedlinePlus

    ... Why do I need a urobilinogen in urine test? Your health care provider may have ordered this test as part ... skin What happens during a urobilinogen in urine test? Your health care provider will need to collect a sample of ...

  1. Design, fabrication and testing of a dual catalyst ammonia removal system for a urine VCD unit

    NASA Technical Reports Server (NTRS)

    Budinikas, P.

    1980-01-01

    A three-man capacity catalytic system for the recovery of water from urine was designed, constructed, and tested, it was designed to operate with feed streams containing high concentrations of urine vapor and only 5 to 7% of oxygen for the oxidation of ammonia and volatile organic vapor.It can operate either in a flow-through or a recycle mode and is capable of accepting the urine vapor produced by a vapor compression distillation evaporator. Testing consisted of short preliminary and optimization test, an endurance test of 74 hours continuous operation, and recycle tests using both air and oxygen. The system was designed for a urine processing rate of 0.86 liters/hr; however, it was tested at rates up to 1.2 liter/hr. Untreated urine evaporated by an electrically heated evaporator was used. The quality of the recovered water meets the U.S. Drinking Water Standards, with the exception of a low pH. Accumulation of solids in the urine sludge is reduced to approximately 65% of the anticipated value.

  2. Uric acid test (image)

    MedlinePlus

    Uric acid urine test is performed to check for the amount of uric acid in urine. Urine is collected over a 24 ... for testing. The most common reason for measuring uric acid levels is in the diagnosis or treatment of ...

  3. Effects of a single glucocorticoid injection on propylene glycol-treated cows with clinical ketosis.

    PubMed

    van der Drift, Saskia G A; Houweling, Martin; Bouman, Marina; Koets, Ad P; Tielens, Aloysius G M; Nielen, Mirjam; Jorritsma, Ruurd

    2015-05-01

    This study investigated the metabolic effects of glucocorticoids when administered to propylene glycol-treated cows with clinical ketosis. Clinical ketosis was defined by depressed feed intake and milk production, and a maximal score for acetoacetate in urine. All cows received 250 mL oral propylene glycol twice daily for 3 days and were randomly assigned to a single intramuscular injection with sterile isotonic saline solution (n = 14) or dexamethasone-21-isonicotinate (n = 17). Metabolic blood variables were monitored for 6 days and adipose tissue variables for 3 days. β-Hydroxybutyrate (BHBA) concentrations in blood decreased in all cows during treatment, but were lower in glucocorticoid-treated cows. Cows treated with glucocorticoids had higher plasma glucose and insulin concentrations, whereas concentrations of non-esterified fatty acids, 3-methylhistidine and growth hormone were unaffected. mRNA expression of hormone-sensitive lipase, BHBA receptor and peroxisome proliferator-activated receptor type γ in adipose tissue was not affected. This shows that lipolytic effects do not appear to be important in ketotic cows when glucocorticoids are combined with PG. Plasma 3-methyl histidine concentrations were similar in both groups, suggesting that glucocorticoids did not increase muscle breakdown and that the greater rise in plasma glucose in glucocorticoid-treated cows may not be due to increased supply of glucogenic amino acids from muscle. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Rapid Diagnosis of Tuberculosis from Analysis of Urine Volatile Organic Compounds

    PubMed Central

    Lim, Sung H.; Martino, Raymond; Anikst, Victoria; Xu, Zeyu; Mix, Samantha; Benjamin, Robert; Schub, Herbert; Eiden, Michael; Rhodes, Paul A.; Banaei, Niaz

    2017-01-01

    The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different urine test conditions. Basified testing condition yielded the best accuracy with 85.5% sensitivity and 79.5% specificity. The CSA urine assay offers desired features needed for tuberculosis diagnosis in endemic settings. PMID:29057329

  5. The efficacy of semi-quantitative urine protein-to-creatinine (P/C) ratio for the detection of significant proteinuria in urine specimens in health screening settings.

    PubMed

    Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh

    2016-01-01

    Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.

  6. Detection of Cytomegalovirus (CMV) Infection in Wheezing Infants by Urine DNA and Serum IgG Testing.

    PubMed

    Zeng, Zhao-Cheng; Chang, Qing; Sun, Zhi-Wei; Song, Ming-Mei; Jin, Xin-Ling; Jiang, Shu-Ya; Yang, Xia

    2017-03-11

    BACKGROUND The aim of this study was to investigate the involvement of CMV infection in wheezing infants and the association between CMV-DNA and immunoglobulins (Igs). MATERIAL AND METHODS A total of 243 wheezing infants and 3,000 parturients were enrolled in this study. The infants were randomly grouped to receive blood HCMV-DNA tests (n=46) or urine HCMV-DNA tests (n=197). Furthermore, all participants had serum CMV-specific IgM and IgG testing. Afterwards, 10 HCMV-IgG positive infants were randomly selected for simultaneous blood and urine HCMV-DNA tests, and 25 HCMV-IgG positive puerperants were randomly selected for urine HCMV-DNA tests. RESULTS The detection rate of urine HCMV-DNA was significantly higher than that of blood HCMV-DNA (67.5% vs. 13.0%, p<0.001). Fifteen (6.2%) and 190 (80.0%) infants showed positive CMV-specific IgM and IgG results (p<0.001), respectively. Among the 10 HCMV-IgG positive infants tested further, only two infants had positive HCMV-DNA blood tests, while all of the 10 infants had positive HCMV-DNA urine tests. However, HCMV-DNA was not detected in the urine of the 25 randomly selected parturients positive for HCMV-IgG. CONCLUSIONS CMV infection may be one of the causes of wheezing in infants; CMV infection can be detected by urine-HCMV-DNA and serum HCMV-IgG testing. Infants were more susceptible to CMV infection than parturients.

  7. Accuracy of simple urine tests for diagnosis of urinary tract infections in low-risk pregnant women.

    PubMed

    Feitosa, Danielle Cristina Alves; da Silva, Márcia Guimarães; de Lima Parada, Cristina Maria Garcia

    2009-01-01

    Anatomic and physiological alterations during pregnancy predispose pregnant women to urinary tract infections (UTI). This study aimed to identify the accuracy of the simple urine test for UTI diagnosis in low-risk pregnant women. Diagnostic test performance was conducted in Botucatu, SP, involving 230 pregnant women, between 2006 and 2008. Results showed 10% UTI prevalence. Sensitivity, specificity and accuracy of the simple urine test were 95.6%, 63.3% and 66.5%, respectively, in relation to UTI diagnoses. The analysis of positive (PPV) and negative (NPV) predictive values showed that, when a regular simple urine test was performed, the chance of UTI occurrence was small (NPV 99.2%). In view of an altered result for such a test, the possibility of UTI existence was small (PPV 22.4%). It was concluded that the accuracy of the simple urine test as a diagnostic means for UTI was low, and that performing a urine culture is essential for appropriate diagnosis.

  8. Diagnostic performance of urine dipstick testing in children with suspected UTI: a systematic review of relationship with age and comparison with microscopy.

    PubMed

    Mori, R; Yonemoto, N; Fitzgerald, A; Tullus, K; Verrier-Jones, K; Lakhanpaul, M

    2010-04-01

    Prompt diagnosis of urinary tract infection (UTI) in children is needed to initiate treatment but is difficult to establish without urine testing, and reliance on culture leads to delay. Urine dipsticks are often used as an alternative to microscopy, although the diagnostic performance of dipsticks at different ages has not been established systematically. Studies comparing urine dipstick testing in infants versus older children and urine dipstick versus microscopy were systematically searched and reviewed. Meta-analysis of available studies was conducted. Six studies addressed these questions. The results of meta-analysis showed that the performance of urine dipstick testing was significantly less in the younger children when compared with older children (p < 0.01). Positive likelihood ratio (LR) of both nitrite and leucocyte positive 38.54 [95% confidence interval (CI) 22.49-65.31], negative LR for both negative 0.13 (95% CI 0.07-0.25) are reasonably good, and those for young infants are less reliable [positive LR 7.62 (95% CI 0.95-51.85) and negative LR 0.34 (95% CI 0.66-0.15)]. Comparing microscopy and urine dipstick testing, using bacterial colony count on urine culture showed no significant difference between the two methods. Urine dipstick testing is more effective for diagnosis of UTI in children over 2 years than for younger children.

  9. Cortisol - urine

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/003703.htm Cortisol urine test To use the sharing features on this page, please enable JavaScript. The cortisol urine test measures the level of cortisol in the ...

  10. Use of a midstream clean catch mobile application did not lower urine contamination rates in an ED.

    PubMed

    Jacob, Mary S; Kulie, Paige; Benedict, Cameron; Ordoobadi, Alexander J; Sikka, Neal; Steinmetz, Erika; McCarthy, Melissa L

    2018-01-01

    Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Direct C-H alkylation and indole formation of anilines with diazo compounds under rhodium catalysis.

    PubMed

    Mishra, Neeraj Kumar; Choi, Miji; Jo, Hyeim; Oh, Yongguk; Sharma, Satyasheel; Han, Sang Hoon; Jeong, Taejoo; Han, Sangil; Lee, Seok-Yong; Kim, In Su

    2015-12-18

    The rhodium(III)-catalyzed direct functionalization of aniline C-H bonds with α-diazo compounds is described. These transformations provide a facile construction of ortho-alkylated anilines with diazo malonates or highly substituted indoles with diazo acetoacetates.

  12. High Glass Transition Temperature Renewable Polymers via Biginelli Multicomponent Polymerization.

    PubMed

    Boukis, Andreas C; Llevot, Audrey; Meier, Michael A R

    2016-04-01

    A novel and straightforward one-pot multicomponent polycondensation method was established in this work. The Biginelli reaction is a versatile multicomponent reaction of an aldehyde, a β-ketoester (acetoacetate) and urea, which can all be obtained from renewable resources, yielding diversely substituted 3,4-dihydropyrimidin-2(1H)-ones (DHMPs). In this study, renewable diacetoacetate monomers with different spacer chain lengths (C3, C6, C10, C20) were prepared via simple transesterification of renewable diols and commercial acetoacetates. The diacetoacetate monomers were then reacted with renewable dialdehydes, i.e., terephthalaldehyde and divanillin in a Biginelli type step-growth polymerization. The obtained DHMP polymers (polyDHMPs) displayed high molar masses, high glass transition temperatures (Tg) up to 203 °C and good thermal stability (Td5%) of 280 °C. The Tg of the polyDHMPs could be tuned by variation of the structure of the dialdehyde or the diacetoacetate component. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Antioxidant and Antimicrobial Activity of 5-methyl-2-(5-methyl-1,3-diphenyl-1H-pyrazole-4-carbonyl)-2,4-dihydro-pyrazol-3-one

    PubMed Central

    Umesha, K. B.; Rai, K. M. L.; Harish Nayaka, M. A.

    2009-01-01

    Cycloaddition of nitrile imines 4 generated in situ by the catalytic dehydrogenation of diphenyl hydrazones 3 using Chloramine-T (CAT) as oxidant in glacial acetic acid with enolic form of ethyl acetoacetate 5 afforded Ethyl 3-aryl-5-methyl-1-phenyl-1H-pyrazol-4-carboxylate 6 in 80% yield. The said pyrazoles 6 refluxed with 80% hydrazine hydrate using absolute alcohol as solvent for about 2–3 hours to produce the respective 5-methyl-1,3-diphenyl-1H-pyrazole-4-carboxylic acid hydrazide 7. The alcoholic solution of pyrazole acid hydrazides on heating with ethyl acetoacetate 5 to give the 5-methyl-2-(5-methyl-1,3-diphenyl-1H-pyrazole-4-carbonyl)-2,4-dihydro-pyrazol-3-one 8. The synthesized compounds were found to exhibit good antimicrobial and antioxidant activity as evaluated by 1,1-diphenyl-2-picryl Hydrazyl (DPPH) radical scavenging, reducing power and DNA protection assays. PMID:23675159

  14. Urine Pretreat Injection System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    A new method of introducing the OXONE (Registered Trademark) Monopersulfate Compound for urine pretreat into a two-phase urine/air flow stream has been successfully tested and evaluated. The feasibility of this innovative method has been established for purposes of providing a simple, convenient, and safe method of handling a chemical pretreat required for urine processing in a microgravity space environment. Also, the Oxone portion of the urine pretreat has demonstrated the following advantages during real time collection of 750 pounds of urine in a Space Station design two-phase urine Fan/Separator: Eliminated urine precipitate buildup on internal hardware and plumbing; Minimized odor from collected urine; and Virtually eliminated airborne bacteria. The urine pretreat, as presently defined for the Space Station program for proper downstream processing of urine, is a two-part chemical treatment of 5.0 grams of Oxone and 2.3 ml of H2SO4 per liter of urine. This study program and test demonstrated only the addition of the proper ratio of Oxone into the urine collection system upstream of the Fan/Separator. This program was divided into the following three major tasks: (1) A trade study, to define and recommend the type of Oxone injection method to pursue further; (2) The design and fabrication of the selected method; and (3) A test program using high fidelity hardware and fresh urine to demonstrate the method feasibility. The trade study was conducted which included defining several methods for injecting Oxone in different forms into a urine system. Oxone was considered in a liquid, solid, paste and powered form. The trade study and the resulting recommendation were presented at a trade study review held at Hamilton Standard on 24-25 October 94. An agreement was reached at the meeting to continue the solid tablet in a bag concept which included a series of tablets suspended in the urine/air flow stream. These Oxone tablets would slowly dissolve at a controlled rate providing the proper concentration in the collected urine. To implement the solid tablet in a bag approach, a design concept was completed with prototype drawings of the complete urine pretreat prefilter assembly. A successful fabrication technique was developed for retaining the Oxone tablets in a fabric casing attached to the end of the existing Space Station Waste Collection System urine prefilter assembly. The final pretreat prefilter configuration held sufficient Oxone in a tablet form to allow normal scheduled daily (or twice daily) change out of the urine filter depending on the use rate of the Space Station urine collection system. The actual tests to prove the concept were conducted using the Urine Fan/Separator assembly that was originally used in the STS-52 Design Test Objective (DTO) urinal assembly. Other related tests were conducted to demonstrate the actual minimum ratio of Oxone to urine that will control microbial growth.

  15. Odor Control Test Report of the Urine Containment Bag (UCB) for Orion Utilization

    NASA Technical Reports Server (NTRS)

    Casper, Stephanie; Williams, Nichole M. M.

    2010-01-01

    The purpose of this report is to summarize the conclusions for the odor control test of the Urine Containment Bag (UCB), P/N SDD46107234-306 in an environment simulating a space craft capsule. JSC 65891, Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization, documents the test plan. The details of the test set-up and data reduction are detailed in the WSTF test report for this test WSTF #10-44500, Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization,. This document outlines the project conclusions and forward plans with regard to trash containment for Constellation.

  16. Utility of urine lipoarabinomannan (LAM) in diagnosing tuberculosis and predicting mortality with and without HIV: prospective TB cohort from the Thailand Big City TB Research Network.

    PubMed

    Suwanpimolkul, Gompol; Kawkitinarong, Kamon; Manosuthi, Weerawat; Sophonphan, Jiratchaya; Gatechompol, Sivaporn; Ohata, Pirapon June; Ubolyam, Sasiwimol; Iampornsin, Thatri; Katerattanakul, Pairaj; Avihingsanon, Anchalee; Ruxrungtham, Kiat

    2017-06-01

    To evaluate the applicability and accuracy of the urine lipoarabinomannan (LAM) test in tuberculosis (TB)/HIV co-infected patients and HIV-negative patients with disseminated TB. Frozen urine samples obtained at baseline from patients in the TB research cohort with proven culture-positive TB were selected for blinded urine LAM testing. One hundred and nine patients were categorized into four groups: (1) HIV-positive patients with TB; (2) HIV-negative patients with disseminated TB; (3) HIV-negative immunocompromised patients with TB; and (4) patients with diseases other than TB. The sensitivity of urine LAM testing for culture-positive TB, specificity of urine LAM testing for patients without TB, positive predictive value (PPV), and negative predictive value (NPV) were assessed. The sensitivity of the urine LAM test in group 1 patients with a CD4 T-cell count of >100, ≤100, and ≤50 cells/mm 3 was 38.5%, 40.6%, and 45%, respectively. The specificity and PPV of the urine LAM test were >80%. The sensitivity of the test was 20% in group 2 and 12.5% in group 3, and the specificity and PPV were 100% for both groups. A positive urine LAM test result was significantly associated with death. This promising diagnostic tool could increase the yield of TB diagnosis and may predict the mortality rate of TB infection, particularly in TB/HIV co-infected patients. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  17. Sodium urine test

    MedlinePlus

    ... or monitor many types of kidney diseases. Normal Results For adults, normal urine sodium values are generally ... meaning of your specific test result. What Abnormal Results Mean A higher than normal urine sodium level ...

  18. Asymptomatic bacteriuria in pregnant women attending Boo-Ali Hospital Tehran Iran: Urine analysis vs. urine culture

    PubMed Central

    Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana

    2017-01-01

    Background Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. Objective The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. Methods A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Results Of 123 urine samples, significant asymptomatic bacteriuria (≥104 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Conclusion Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and specificity of 100%, whereas we can only refer the pregnant women with positive leucocyte esterase test and significant pyuria to the urine culture. PMID:29403616

  19. Uric acid - urine

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003616.htm Uric acid urine test To use the sharing features on this page, please enable JavaScript. The uric acid urine test measures the level of uric acid ...

  20. 75 FR 39023 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-07

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  1. 75 FR 27348 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-14

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  2. 75 FR 9229 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-01

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  3. 75 FR 5088 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-01

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  4. 75 FR 154 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-04

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  5. 75 FR 45128 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-02

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the..., ``Certification of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  6. 75 FR 32950 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-10

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  7. 75 FR 55795 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-14

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  8. Urinalysis and associated laboratory procedures.

    PubMed

    Brobst, D

    1989-09-01

    Macroscopic examination of urine is an integral part of urinalysis, and blood and bile pigments are a common cause of abnormal coloration. Urine SG is a convenient index of urine concentration and should be correlated with the patient's hydration status to determine the ability of the kidneys to concentrate and dilute urine. The pH of urine of dogs and cats normally is dietary dependent, but alkaline urine may suggest that the urinary tract is infected with a urea splitting organism. The dipstick test for proteinuria is convenient but less reliable than the sulfosalicylic acid method. The dipstick test for blood should not be used as a substitute for microscopic examination of urine but is of value in detecting hemoglobinuria and myoglobinuria, when red cells may be absent in the sediment. The finding of glucose, ketones, and bilirubin in urine, when interpreted properly, may indicate the presence of disease processes not associated with the urogenital tract. Microscopic examination of urine sediment must be interpreted in combination with the physical and chemical composition of urine, but excessive numbers of cells, casts, crystals, and bacteria may provide evidence of disease. The absence of these structures in the sediment, however, does not eliminate the possibility of disease. The ability of the kidneys to concentrate urine is dependent on normal kidney function and the production and release of ADH. A urine SG greater than 1.030 in dogs and 1.035 in cats indicates that the functions associated with concentrating urine are adequate. In the evaluation of the patient's ability to form concentrated urine, the status of hydration must be considered; this may require water deprivation tests or administration of ADH. The estimation of blood urea nitrogen concentration, with the use of test strips, may provide a convenient but not specific measure of renal function.

  9. Performance of the dipstick screening test as a predictor of negative urine culture

    PubMed Central

    Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle

    2017-01-01

    ABSTRACT Objective To investigate whether the urine dipstick screening test can be used to predict urine culture results. Methods A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. Results The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). Conclusion A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. PMID:28444086

  10. Study on color difference estimation method of medicine biochemical analysis

    NASA Astrophysics Data System (ADS)

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Sun, Jiashi; Zhou, Fengkun

    2006-01-01

    The biochemical analysis in medicine is an important inspection and diagnosis method in hospital clinic. The biochemical analysis of urine is one important item. The Urine test paper shows corresponding color with different detection project or different illness degree. The color difference between the standard threshold and the test paper color of urine can be used to judge the illness degree, so that further analysis and diagnosis to urine is gotten. The color is a three-dimensional physical variable concerning psychology, while reflectance is one-dimensional variable; therefore, the estimation method of color difference in urine test can have better precision and facility than the conventional test method with one-dimensional reflectance, it can make an accurate diagnose. The digital camera is easy to take an image of urine test paper and is used to carry out the urine biochemical analysis conveniently. On the experiment, the color image of urine test paper is taken by popular color digital camera and saved in the computer which installs a simple color space conversion (RGB -> XYZ -> L *a *b *)and the calculation software. Test sample is graded according to intelligent detection of quantitative color. The images taken every time were saved in computer, and the whole illness process will be monitored. This method can also use in other medicine biochemical analyses that have relation with color. Experiment result shows that this test method is quick and accurate; it can be used in hospital, calibrating organization and family, so its application prospect is extensive.

  11. Accuracy of urinary human papillomavirus testing for presence of cervical HPV: systematic review and meta-analysis

    PubMed Central

    Pathak, Neha; Dodds, Julie; Khan, Khalid

    2014-01-01

    Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064

  12. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    PubMed

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  13. Primary Care Providers’ Experiences with Urine Toxicology Tests to Manage Prescription Opioid Misuse and Substance Use Among Chronic Non-Cancer Pain Patients in Safety Net Healthcare Settings

    PubMed Central

    Ceasar, Rachel; Chang, Jamie; Zamora, Kara; Hurstak, Emily; Kushel, Margot; Miaskowski, Christine; Knight, Kelly

    2016-01-01

    Background Guideline recommendations to reduce prescription opioid misuse among patients with chronic non-cancer pain include the routine use of urine toxicology tests for high-risk patients. Yet little is known about how the implementation of urine toxicology tests among patients with co-occurring chronic non-cancer pain and substance use impacts primary care providers’ management of misuse. In this paper, we present clinicians’ perspectives on the benefits and challenges of implementing urine toxicology tests in the monitoring of opioid misuse and substance use in safety net healthcare settings. Methods We interviewed 23 primary care providers from six safety net healthcare settings whose patients had a diagnosis of co-occurring chronic non-cancer pain and substance use. We transcribed, coded, and analyzed interviews using grounded theory methodology. Results The benefits of implementing urine toxicology tests for primary care providers included less reliance on intuition to assess for misuse and the ability to identify unknown opioid misuse and/or substance use. The challenges of implementing urine toxicology tests included insufficient education and training about how to interpret and implement tests, and a lack of clarity on how and when to act on tests that indicated misuse and/or substance use. Conclusions These data suggest that primary care clinicians’ lack of education and training to interpret and implement urine toxicology tests may impact their management of patient opioid misuse and/or substance use. Clinicians may benefit from additional education and training about the clinical implementation and use of urine toxicology tests. Additional research is needed on how primary care providers implementation and use of urine toxicology tests impacts chronic non-cancer pain management in primary care and safety net healthcare settings among patients with co-occurring chronic non-cancer pain and substance use. PMID:26682471

  14. Blood in Urine: MedlinePlus Lab Test Information

    MedlinePlus

    ... Information → Blood in Urine URL of this page: https://medlineplus.gov/labtests/bloodinurine.html Blood in Urine ... 2017 Mar 14]; [about 4 screens]: Available from: https://labtestsonline.org/understanding/analytes/urinalysis/tab/test Lab ...

  15. Nitrites in Urine

    MedlinePlus

    ... Why do I need a nitrites in urine test? Your health care provider may have ordered a urinalysis as part ... Fever What happens during a nitrites in urine test? Your health care provider will need to collect a sample of ...

  16. Lab Test Information

    MedlinePlus

    ... Mumps Tests MPV Blood Test Mucus in Urine N Nitrites in Urine P Pap Smear Porphyrin Test ... V Vitamin D Test Vitamin E (tocopherol) Test Y Yeast Infection Test Related MedlinePlus Health Topics Laboratory ...

  17. 51Cr-EDTA absorption blood test: an easy method for assessing small intestinal permeability in dogs.

    PubMed

    Frias, Rafael; Sankari, Satu; Westermarck, Elias

    2004-01-01

    The 51Cr-EDTA test is a valuable clinical tool for screening intestinal diseases in dogs. The test is performed by calculating the percentage of recovery from urine of a PO-ingested dose of 51Cr-EDTA after 6 or 24 hours. Careful urine collection is a practical limitation of this test in dogs, and our goal was to develop a simpler test that measures 51Cr-EDTA in blood. A 51Cr-EDTA absorption test was simultaneously performed on urine and serum 43 times in healthy Beagle Dogs. Timed blood samples were withdrawn, and urine was collected during a 6-hour period. Percentages of the ingested dose were then calculated in urine and serum. The mean +/- standard deviation (range) percentage in urine after 6 hours was 14.07 +/- 8.72% (3.81-34.18%), whereas results in serum from samples taken at 2, 3, 4, 5, and 6 hours were 0.49 +/- 0.45% (0.02-2.13%), 0.75 +/- 0.52% (0.03-1.89%), 0.82 +/- 0.57% (0.13-2.21%), 0.70 +/- 0.53% (0.12-1.99%), and 0.47 +/- 0.44% (0.11-1.79%), respectively. The results for blood specimens showed good concordance with those for urine, especially for the samples taken at 4 hours (r = 0.89). Moreover, the correlation between urine and blood was better when the sum of the percentages of the recovered analyte from various blood samples was compared with urine. The correlation coefficient when summing 4 blood samples was excellent (r = 0.97) and remained excellent when summing only 2 blood samples taken at 3 and 5 hours (r = 0.95) or at 3 and 4 hours (r = 0.94). We conclude that a serum 51Cr-EDTA test determined by summing successive blood samples provides an easier means of estimating small intestinal permeability in dogs and gives results comparable to those of the 6-hour urine test.

  18. Urine test for HPV genotypes as a predictor of precancerous cervical lesions and for cervical cancer screening.

    PubMed

    Maged, Ahmed M; Saad, Hany; Salah, Emad; Meshaal, Hadeer; AbdElbar, Mostafa; Omran, Eman; Eldaly, Ashraf

    2018-06-01

    To assess the sensitivity of a urine test for high-risk HPV DNA genotypes in the detection of high-grade squamous intra-epithelial lesion (HSIL) and its correlation with pathologic precancerous lesions. The present prospective cross-sectional study included women referred to Kasr AlAiny Medical School, Cairo, Egypt, for cervical smear anomalies, a history of cervical smear anomalies, or for suspicious cervix between May 1, 2015, and April 30, 2017. Paired urine tests and cervical smears were performed. HPV DNA was detected in urine using polymerase chain reaction and cervical smears were performed with a cervical spatula and a cytobrush. Agreement between urine test results and pathology was examined. In total, 1375 women were included. Urine test for high-risk HPV DNA demonstrated 97.8% (95% confidence interval [CI] 92.1%-99.7%) sensitivity and 100% (95% CI 99.7%-100.0%) specificity for HSIL. Overall, 87 women had a positive urine test for high-risk HPV; of these, 82 (94.3%, 95% CI 87.1%-98.1%) had pathologic findings of cervical intra-epithelial neoplasia 2 or 3 (CIN2/3). Similarly, 89 women had HSIL cytology; again, 82 had CIN2/3 (92.1%; 95% CI, 84.3%-96.4%). There was good agreement between a positive urine test for high-risk HPV DNA genotypes and pathologic findings of CIN2/3. © 2018 International Federation of Gynecology and Obstetrics.

  19. Epithelial Cells in Urine: MedlinePlus Lab Test Information

    MedlinePlus

    ... page: https://medlineplus.gov/labtests/epithelialcellsinurine.html Epithelial Cells in Urine To use the sharing features on ... page, please enable JavaScript. What is an Epithelial Cells in Urine Test? Epithelial cells are a type ...

  20. Compatibility Testing of Non-Metallic Materials for the Urine Processor Assembly (UPA) of International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)

    2001-01-01

    In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA). The urine is distilled, with the concentrated form containing about 15% brine solids, and the dilute form as a blend of pre-treated urine/wastewater. Eighteen candidate non-metallic materials for use with the UPA were tested in 2000 for compatibility with the concentrated and dilute urine solutions for continuous times of at least 30 days, and at conditions of 0.5 psia pressure and 100 F, to simulate the working UPA environment. A primary screening test for each material (virgin and conditioned) was dynamic mechanical analysis (DMA) in the stress relaxation mode, with the test data used to predict material performance for a 10-year use in space. Data showed that most of the candidate materials passed the compatibility testing, although a few significant changes in stress relaxation modulus were observed.

  1. [Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].

    PubMed

    Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo

    2016-03-01

    The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.

  2. Sole Dependence on Urine Testing Strips and the Ability to Identify Clinically Significant Disease: Challenging the Current Paradigm for Heme Detection in General Clinical Situations.

    PubMed

    Rothschild, Bruce

    2016-05-01

    The ability of health care professionals to provide patient care is potentially compromised when predicated on untested, although longstanding, perspectives. One such example is urinalysis testing, which has been currently simplified to use only urine testing strips for detection of microscopic hematuria. To determine whether urine testing strips are sufficient for identification of clinically significant findings in urinalysis. To determine the presence of microscopic hematuria, I examined a collection of urine specimens that had tested heme negative during the 3-month study period. Of the 342 patients from whom urine specimens were examined during this interval, 50 had microscopic hematuria, despite having tested negative for heme via urine testing strip. Also, 30% were not receiving any medication known to produce microscopic hematuria, and 18% had clinically significant pathology. Diagnosis of significant clinical pathologic manifestations would have been compromised had microscopic examination not been performed on the urine specimens from the cohort individuals. Examination of the novel approach of including microscopic examination of specimens in a specific clinical situation challenges the dominant paradigm of reliance on assaying using urine testing strips only, revealing that the current method is not only unreliable for determining microscopic hematuria but also is less than optimal in general clinical practice. The findings of this study provide evidence of the importance of microscopic evaluation as a routine component of urinalysis. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    PubMed

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV detection in urine. Thus, urine samples may be an effective alternative for HPV detection in women who hesitate to participate in cervical cancer screening programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. PBG urine test

    MedlinePlus

    ... test. Alternative Names Porphobilinogen test; Porphyria - urine; PBG Images Male urinary system References Fuller SJ, Wiley JS. Heme biosynthesis and its disorders: porphyrias and sideroblastic ...

  5. Noninvasive and Painless Urine Glucose Detection by Using Computer-based Polarimeter

    NASA Astrophysics Data System (ADS)

    Sutrisno; Laksono, Y. A.; Hidayat, N.

    2017-05-01

    Diabetes kills millions of people worldwide each year. It challenges us as researchers to give contribution in early diagnosis to ensure a healthy life. As a matter of fact, common glucose testing devices that have been widely used so far are, at least, glucose meter and urine glucose test strip. The glucose meter ordinarily requires blood taken from patient’s finger. The glucose test strip uses patient’s urine but records unspecific urine glucose level, since the strip only provides the glucose level in some particular ranges. Instead of detecting the glucose level in blood and using the non-specific technique, a noninvasive and painless technique that can detect glucose level accurately will provide a more feasible approach for diabetes diagnosis. The noninvasive and painless urine glucose level monitoring by means of computer-based polarimeter is presented in this paper. The instrument consisted of a power source, a sample box, a light sensor, a polarizer, an analyzer, an analog to digital converter (ADC), and a computer. The concentration of urine glucose concentration was evaluated from the curve of the change in detected optical rotation angle and output potential by the computer-based polarimeter. Statistical analyses by means of Gaussian fitting and linear regression were applied to investigate the rotation angle and urine glucose concentration, respectively. From our experiment, the urine glucose level, measured by glucose test strips, of the normal patient was 100 mg/dl, and the diabetic patient was 500 mg/dl. Our polarimeter even read more precise values for the urine glucose concentrations of those normal and diabetic of the same patients, i.e. 50.61 mg/dl and 502.41 mg/dl, respectively. In other words, the results showed that our polarimeter was able to quantitatively measure the urine glucose level more accurate than urine glucose test strips. Hence, this computer-based polarimeter could be used as an alternative for early detection of urine glucose with noninvasive and painless characteristics.

  6. The use of semi-quantitative tests at Cesarean section delivery for the differentiation of canine fetal fluids from maternal urine on the basis of biochemical characteristics.

    PubMed

    Balogh, Orsolya; Roch, Marie; Keller, Stefanie; Michel, Erika; Reichler, Iris M

    2017-01-15

    In dogs, there is no diagnostic test to identify and differentiate fetal fluids from maternal urine in the event that a clear-yellowish vulvar discharge is observed pre-whelping. The objective of this study was to find a test that could easily and accurately identify rupture of the fetal membranes preceding parturition. Maternal urine, and amniotic fluid (AMF) and allantoic fluid (ALF) from only one fetus per bitch, were collected intraoperatively during Cesarean section. Specific gravity (SG) was analyzed with a refractometer, whereas the presence of leukocytes, protein, glucose, ketones, bilirubin, urobilinogen, nitrite, erythrocyte/hemoglobin (Hb), and the pH were assessed using a urine dipstick (Combur-Test ® ). Combined calcium and magnesium (Ca/Mg) content were evaluated with the Total Hardness Test. The AmniSure test, which detects rupture of fetal membranes in women on the basis of the presence of human placental alpha microglobulin-1, was also performed on canine AMF, ALF, and urine. Data were analyzed using the Fisher's exact test, Wilcoxon signed-rank test, and Pearson's correlation. Sensitivity, specificity, and positive and negative likelihood ratios (LR) were calculated for parameters with significant difference between urine and both fetal fluids. Maternal urine had higher SG and lower leukocyte, protein, Hb, and Ca/Mg content than AMF and ALF. Glucose was more often present in AMF (n = 17) and ALF (n = 12) than in urine (n = 1), whereas ketone bodies were rarely detected in ALF compared with urine. Bilirubin content was higher in urine and ALF than in AMF. AMF pH was less variable and higher than the pH of ALF or urine. The AmniSure was negative in all samples tested. Sensitivity and specificity for SG and for the detection of leukocytes, protein, glucose, Hb, Ca/Mg, and glucose without ketones in urine and fetal fluids were between 42% to 100% and 65% to 100%, respectively. Best positive LR was achieved for the detection of glucose without ketones and best negative LR for SG of 1.022 or less. In conclusion, the AmniSure test, which is used in humans with high diagnostic accuracy, cannot identify AMF and ALF in dogs. On the basis of our results in 26 dogs undergoing Cesarean section, the presence or absence of fetal fluids could be best determined by a positive glucose test without ketone bodies or by SG higher than 1.022, respectively. These tests may serve as additional tools to recognize parturition if clear-yellowish vulvar discharge is present in a term pregnant bitch, but their accuracy and practicability in the clinical setting need to be confirmed. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Isomorphic red blood cells using automated urine flow cytometry is a reliable method in diagnosis of bladder cancer.

    PubMed

    Muto, Satoru; Sugiura, Syo-Ichiro; Nakajima, Akiko; Horiuchi, Akira; Inoue, Masahiro; Saito, Keisuke; Isotani, Shuji; Yamaguchi, Raizo; Ide, Hisamitsu; Horie, Shigeo

    2014-10-01

    We aimed to identify patients with a chief complaint of hematuria who could safely avoid unnecessary radiation and instrumentation in the diagnosis of bladder cancer (BC), using automated urine flow cytometry to detect isomorphic red blood cells (RBCs) in urine. We acquired urine samples from 134 patients over the age of 35 years with a chief complaint of hematuria and a positive urine occult blood test or microhematuria. The data were analyzed using the UF-1000i (®) (Sysmex Co., Ltd., Kobe, Japan) automated urine flow cytometer to determine RBC morphology, which was classified as isomorphic or dysmorphic. The patients were divided into two groups (BC versus non-BC) for statistical analysis. Multivariate logistic regression analysis was used to determine the predictive value of flow cytometry versus urine cytology, the bladder tumor antigen test, occult blood in urine test, and microhematuria test. BC was confirmed in 26 of 134 patients (19.4 %). The area under the curve for RBC count using the automated urine flow cytometer was 0.94, representing the highest reference value obtained in this study. Isomorphic RBCs were detected in all patients in the BC group. On multivariate logistic regression analysis, only isomorphic RBC morphology was significantly predictive for BC (p < 0.001). Analytical parameters such as sensitivity, specificity, positive predictive value, and negative predictive value of isomorphic RBCs in urine were 100.0, 91.7, 74.3, and 100.0 %, respectively. Detection of urinary isomorphic RBCs using automated urine flow cytometry is a reliable method in the diagnosis of BC with hematuria.

  8. Urine Test: Microalbumin-to-Creatinine Ratio (For Parents)

    MedlinePlus

    ... involves measuring the amount of a protein called albumin in the urine (pee). The amount of urine albumin is compared with the quantity of a waste ... steady rate, so comparing the ratio of urine albumin with creatinine in the same urine specimen helps ...

  9. Urine Pretreatment Configuration and Test Results for Space Applications

    NASA Technical Reports Server (NTRS)

    Howard, Stanley G.; Hutchens, Cindy F.; Rethke, Donald W.; Swartley, Vernon L.; Marsh, Robert W.

    1998-01-01

    Pretreatment of urine using Oxone and sulfuric acid is baselined in the International Space Station (ISS) waste water reclamation system to control odors, fix urea and control microbial growth. In addition, pretreatment is recommended for long term flight use of urine collection and two phase separation to reduce or eliminate fouling of the associated hardware and plumbing with urine precipitates. This is important for ISS application because the amount of maintenance time for cleaning and repairing hardware must be minimized. This paper describes the development of a chemical pretreatment system based on solid tablet shapes which are positioned in the urine collection hose and are dissolved by the intrained urine at the proper ratio of pretreatment to urine. Building upon the prior success of the developed and tested solid Oxone tablet a trade study was completed to confirm if a similar approach, or alternative, would be appropriate for the sulfuric acid injection method. In addition, a recommended handling and packaging approach of the solid tablets for long term, safe and convenient use on ISS was addressed. Consequently, the solid tablet concept with suitable packaging was identified as the Urine Pretreat / Prefilter Assembly (UPPA). Testing of the UPPA configuration confirmed the disolution rates and ratios required by ISS were achieved. This testing included laboratory controlled methods as well as a 'real world' test evaluation that occurred during the 150 day Stage 10 Water Recovery Test (WRT) conducted at NASA Marshall Space Flight Center (MSFC).

  10. Osmolality urine test

    MedlinePlus

    ... balance and urine concentration. Osmolality is a more exact measurement of urine concentration than the urine specific ... must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get ...

  11. 24-hour urinary aldosterone excretion test

    MedlinePlus

    Aldosterone - urine; Addison disease - urine aldosterone; Cirrhosis - serum aldosterone ... A 24-hour urine sample is needed. You will need to collect your urine over 24 hours . Your health care provider will tell ...

  12. Citric acid urine test

    MedlinePlus

    Urine - citric acid test; Renal tubular acidosis - citric acid test; Kidney stones - citric acid test; Urolithiasis - citric acid test ... No special preparation is necessary for this test. But the results ... test is usually done while you are on a normal diet. Ask your ...

  13. Urine drug testing results and paired oral fluid comparison from patients enrolled in long-term medication-assisted treatment in Tennessee.

    PubMed

    Miller, Katie L; Puet, Brandi L; Roberts, Ali; Hild, Cheryl; Carter, Jason; Black, David L

    2017-05-01

    Urine drug testing is recommended for individuals receiving medication-assisted treatment. It provides objective information for practitioners to consider and may serve as a protective factor against drug-related mortality. The primary objective of our study was to describe urine drug testing results for patients undergoing long-term medication-assisted treatment (≥6months). The secondary objective was to provide further evidence to establish oral fluid as a reliable alternative to urine. All subjects (n=639) included in the study were enrolled in one of five treatment centers in the state of Tennessee, and all urine specimens were positive for either methadone or buprenorphine. Nicotine (87%), caffeine (70%), marijuana (15%), alcohol (14%) and gabapentin (10%) were the most prevalent substances identified through urine drug testing. The presence of non-maintenance opioids (prescription and/or heroin) may represent relapse; these drugs were present in 10% of specimens tested. Evidence of illicit drug use (cocaine, heroin, marijuana and/or methamphetamine) was detected in 19% specimens. For 126 of the 639 subjects included in the study, paired oral fluid and urine test results were compared for agreement. Of the total paired urine and oral fluid tests, approximately 7% were positive for a drug in both specimen types and 91% were negative in both, resulting in an overall agreement of 98%. The study demonstrates continued use of illicit and commercially available medications in a medication-assisted treatment population undergoing long-term treatment. The results affirm the reliability of oral fluid as an alternative specimen type for compliance testing in this population. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Urine pretreatment for waste water processing systems. [for space station

    NASA Technical Reports Server (NTRS)

    Winkler, H. E.; Verostko, C. E.; Dehner, G. F.

    1983-01-01

    Recovery of high quality water from urine is an essential part of life support on a Space Station to avoid costly launch and resupply penalties. Water can be effectively recovered from urine by distillation following pretreatment by a chemical agent to inhibit microorganism contamination and fix volatile ammonia constituents. This paper presents the results of laboratory investigations of several pretreatment chemicals which were tested at several concentration levels in combination with sulfuric acid in urine. The optimum pretreatment formulation was then evaluated with urine in the Hamilton Standard Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES). Over 2600 hours of test time was accumulated. Results of these laboratory and system tests are presented in this paper.

  15. European guidelines for workplace drug testing in urine.

    PubMed

    Taskinen, Sanna; Beck, Olof; Bosch, Tessa; Brcak, Michaela; Carmichael, Duncan; Fucci, Nadia; George, Claire; Piper, Mark; Salomone, Alberto; Schielen, Wim; Steinmeyer, Stefan; Weinmann, Wolfgang

    2017-06-01

    These European Guidelines for Workplace Drug Testing in Urine have been prepared and updated by the European Workplace Drug Testing Society (EWDTS). The first version of these urine guidelines was published in 2002. Since then, the guidelines have been followed by many laboratories in different European countries and their role has been essential particularly in countries lacking legislation for workplace drug testing. In 2014, the EWDTS started a guidelines updating project and published a new version of the urine guidelines in 2015. Here we represent this updated version of the urine guidelines. The European Guidelines are designed to establish best practice procedures whilst allowing individual countries to operate within the requirements of national customs and legislation. The EWDTS recommends that all European laboratories that undertake legally defensible workplace drug testing should use these guidelines as a template for accreditation. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Survey of antibiotic residues in Canadian slaughter animals.

    PubMed Central

    Tittiger, F; Kingscote, B; Meldrum, B; Prior, M

    1975-01-01

    Kidneys and urine of cattle, swine, sheep and chickens were tested for bacterial growth inhibitors using Bacillus subtilis and Sarcina lutea as test organisms. Results were as follows: 211 beef kidneys four positive, 611 swine kidneys five positive, 27 sheep and 120 chicken kidneys all negative, 2108 beef urine 76 positive, 2409 swine urine 186 positive, 176 sheep urine 17 positive. Strongest reactions were obtained with B. subtilis on phosphate buffered pH 6.0 plates. Larger zones were produced by urine from injected animals than by tissue samples. PMID:236082

  17. Use of Enzymes in Organic Synthesis: Reduction of Ketones by Baker's Yeast Revisited

    ERIC Educational Resources Information Center

    Patterson, James; Sigurdsson, Snorri Th.

    2005-01-01

    The reduction of ethyl acetoacetate using common baker's yeast is a traditional experiment that shows the stereoselective power of a biochemical system. Addition of organic solvents to aqueous reaction system increased the yields and reproducibility of the experiment thus overcoming the two problems associated with the experiment, low yield, and…

  18. Activation of Acetone and Other Simple Ketones in Anaerobic Bacteria.

    PubMed

    Heider, Johann; Schühle, Karola; Frey, Jasmin; Schink, Bernhard

    2016-01-01

    Acetone and other ketones are activated for subsequent degradation through carboxylation by many nitrate-reducing, phototrophic, and obligately aerobic bacteria. Acetone carboxylation leads to acetoacetate, which is subsequently activated to a thioester and degraded via thiolysis. Two different types of acetone carboxylases have been described, which require either 2 or 4 ATP equivalents as an energy supply for the carboxylation reaction. Both enzymes appear to combine acetone enolphosphate with carbonic phosphate to form acetoacetate. A similar but more complex enzyme is known to carboxylate the aromatic ketone acetophenone, a metabolic intermediate in anaerobic ethylbenzene metabolism in denitrifying bacteria, with simultaneous hydrolysis of 2 ATP to 2 ADP. Obligately anaerobic sulfate-reducing bacteria activate acetone to a four-carbon compound as well, but via a different process than bicarbonate- or CO2-dependent carboxylation. The present evidence indicates that either carbon monoxide or a formyl residue is used as a cosubstrate, and that the overall ATP expenditure of this pathway is substantially lower than in the known acetone carboxylase reactions. © 2016 S. Karger AG, Basel.

  19. Timing of specimen collection is crucial in urine screening of drug dependent mothers and newborns.

    PubMed

    Halstead, A C; Godolphin, W; Lockitch, G; Segal, S

    1988-01-01

    We compared results of urine drug analysis with clinical data and history to test the usefulness of peripartum drug screening and to establish guidelines for optimal testing. Urine from 28 mothers and 52 babies was analysed. Drugs not suspected by history were found in 10 mothers and six babies. Results assisted in the management of neonatal withdrawal in three babies. Drugs suspected by history were not found in 11/22 mothers and 23/35 babies. About half of these results were associated with delayed urine collection. In 12/28 mothers, drugs administered in hospital could have confused interpretation of screen results. We conclude that urine drug screening without strict protocols for specimen collection is of limited usefulness for management of drug abuse in pregnancy and neonatal drug withdrawal. We favour testing of maternal urine obtained before drugs are administered in hospital. Neonatal urine, if used, should be collected in the first day of life.

  20. Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?

    PubMed Central

    Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok

    2012-01-01

    Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881

  1. Impact of probability estimation on frequency of urine culture requests in ambulatory settings.

    PubMed

    Gul, Naheed; Quadri, Mujtaba

    2012-07-01

    To determine the perceptions of the medical community about urine culture in diagnosing urinary tract infections. The cross-sectional survey based of consecutive sampling was conducted at Shifa International Hospital, Islamabad, on 200 doctors, including medical students of the Shifa College of Medicine, from April to October 2010. A questionnaire with three common clinical scenarios of low, intermediate and high pre-test probability for urinary tract infection was used to assess the behaviour of the respondents to make a decision for urine culture test. The differences between the reference estimates and the respondents' estimates of pre- and post-test probability were assessed. The association of estimated probabilities with the number of tests ordered was also evaluated. The respondents were also asked about the cost effectiveness and safety of urine culture and sensitivity. Data was analysed using SPSS version 15. In low pre-test probability settings, the disease probability was over-estimated, suggesting the participants' inability to rule out the disease. The post-test probabilities were, however, under-estimated by the doctors as compared to the students. In intermediate and high pre-test probability settings, both over- and underestimation of probabilities were noticed. Doctors were more likely to consider ordering the test as the disease probability increased. Most of the respondents were of the opinion that urine culture was a cost-effective test and there was no associated potential harm. The wide variation in the clinical use of urine culture necessitates the formulation of appropriate guidelines for the diagnostic use of urine culture, and application of Bayesian probabilistic thinking to real clinical situations.

  2. The impact on accuracy and cost of ligase chain reaction testing by pooling urine specimens for the diagnosis of Chlamydia trachomatis infections.

    PubMed

    Krepel, J; Patel, J; Sproston, A; Hopkins, F; Jang, D; Mahony, J; Chernesky, M

    1999-10-01

    Nucleic acid amplification testing is the most accurate approach to diagnosing Chlamydia trachomatis infections. Our objective was to compare the accuracy and cost savings of pooling urines as opposed to individual testing. Strategies of pooling urine specimens into groups of four (4x pool) or eight (8x pool) followed by testing the positive pools individually were compared to individual specimen testing to determine if significant cost savingS could be realized without compromising the sensitivity and specificity of the LCx C. trachomatis Assay (Abbott Laboratories, Abbott Park, Chicago, IL) performed in a busy private medical laboratory. A total of 1,220 patient urine samples, 1,187 male (97%) and 33 female (3%), were tested using the normal LCx specimen to cutoff ratio (S/CO) of 1.0 and a decreased S/CO value of 0.2. Individual testing identified 98.2% (109/111) of positive urines. The 4x pooling maneuver identified 92.8% (103/111) of positive patients with the regular cutoff and 96.4% (107/111) when the cutoff was decreased. These values were 95.9% (47/49) and 97.9% (48/49), respectively, when eight urines were pooled. Both pooling and individual testing strategies identified all the negative samples accurately. Cost savings of pooling were calculated to be 44.5% for pools of four and 37.5% for pools of eight, applying the lowered cutoff. Pooling urine specimens for testing with the C. trachomatis LCx system is a simple, accurate, and cost-saving approach that can significantly reduce the cost of amplified nucleic acid testing with minimal sacrifice of testing accuracy.

  3. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  4. Use of urine testing in outpatients treated for urinary tract infection.

    PubMed

    Copp, Hillary L; Yiee, Jenny H; Smith, Alexandria; Hanley, Janet; Saigal, Christopher S

    2013-09-01

    To characterize urine test use in ambulatory, antibiotic-treated pediatric urinary tract infection (UTI). We studied children <18 years who had an outpatient UTI and a temporally associated antibiotic prescription from 2002 through 2007 by using a large claims database, Innovus i3. We evaluated urine-testing trends and performed multivariable logistic regression to assess for factors associated with urine culture use. Of 40 603 treated UTI episodes in 28 678 children, urinalysis was performed in 76%, and urine culture in 57%; 32% of children <2 years had no urinalysis or culture performed for an antibiotic-treated UTI episode. Urine culture use decreased during the study period from 60% to 54% (P < .001). We observed variation in urine culture use with age (<2 years: odds ratio [OR] 1.0, 95% confidence interval [CI] 0.9-1.1; 2-5 years: OR 1.3, 95% CI 1.2-1.4; 6-12 years: OR 1.3, 95% CI 1.2-1.4, compared with 13-17 years); gender (boys: OR 0.8, 95% CI 0.8-0.9); and specialty (pediatrics: OR 2.6, 95% CI 2.5-2.8; emergency medicine, OR 1.2, 95% CI 1.1-1.3; urology: OR 0.5, 95% CI 0.4-0.6, compared with family/internal medicine). Recent antibiotic exposure (OR 1.1, 95% CI 1.1-1.2) and empirical broad-spectrum prescription (OR 1.2, 95% CI 1.1-1.2) were associated with urine culture use, whereas previous UTI and urologic anomalies were not. Providers often do not obtain urine tests when prescribing antibiotics for outpatient pediatric UTI. Variation in urine culture use was observed based on age, gender, and physician specialty. Additional research is necessary to determine the implications of empirical antibiotic prescription for pediatric UTI without confirmatory urine testing.

  5. Use of Urine Testing in Outpatients Treated for Urinary Tract Infection

    PubMed Central

    Yiee, Jenny H.; Smith, Alexandria; Hanley, Janet; Saigal, Christopher S.

    2013-01-01

    OBJECTIVE: To characterize urine test use in ambulatory, antibiotic-treated pediatric urinary tract infection (UTI). METHODS: We studied children <18 years who had an outpatient UTI and a temporally associated antibiotic prescription from 2002 through 2007 by using a large claims database, Innovus i3. We evaluated urine-testing trends and performed multivariable logistic regression to assess for factors associated with urine culture use. RESULTS: Of 40 603 treated UTI episodes in 28 678 children, urinalysis was performed in 76%, and urine culture in 57%; 32% of children <2 years had no urinalysis or culture performed for an antibiotic-treated UTI episode. Urine culture use decreased during the study period from 60% to 54% (P < .001). We observed variation in urine culture use with age (<2 years: odds ratio [OR] 1.0, 95% confidence interval [CI] 0.9–1.1; 2–5 years: OR 1.3, 95% CI 1.2–1.4; 6–12 years: OR 1.3, 95% CI 1.2–1.4, compared with 13–17 years); gender (boys: OR 0.8, 95% CI 0.8–0.9); and specialty (pediatrics: OR 2.6, 95% CI 2.5–2.8; emergency medicine, OR 1.2, 95% CI 1.1–1.3; urology: OR 0.5, 95% CI 0.4–0.6, compared with family/internal medicine). Recent antibiotic exposure (OR 1.1, 95% CI 1.1–1.2) and empirical broad-spectrum prescription (OR 1.2, 95% CI 1.1–1.2) were associated with urine culture use, whereas previous UTI and urologic anomalies were not. CONCLUSIONS: Providers often do not obtain urine tests when prescribing antibiotics for outpatient pediatric UTI. Variation in urine culture use was observed based on age, gender, and physician specialty. Additional research is necessary to determine the implications of empirical antibiotic prescription for pediatric UTI without confirmatory urine testing. PMID:23918886

  6. [Is bacteriological testing of bladder urine informative in acute obstructive pyelo- nephritis?

    PubMed

    Kogan, M I; Naboka, Yu L; Bedzhanyan, S K; Mitusova, E V; Gudima, I A; Morgun, P P; Vasileva, L I

    2017-07-01

    The problem of the etiology and pathogenesis of acute obstructive pyelonephritis (OOP) remains one of the challenging issues of modern urology. Etiological agents of pyelonephritis can be both gram-negative and gram-positive opportunistic bacteria mostly belonging to the normal flora in humans. The generally accepted diagnostic work-up involves a bacteriological testing of not pelvic urine, but of bladder urine collected by a transurethral catheter or midstream specimens of urine collected from the patients. The aim of our study was to compare the microbiota of bladder and pelvic urine in patients with OOP. The study comprised 72 sequentially selected patients (12 men and 60 women) with OOP associated with ureteral stones. Mean age of patients was 53.7+/-0.5 years. All patients underwent bacteriological examination of the bladder urine collected by a transurethral catheter and pelvic urine obtained after relieving stone-related ureteral obstruction. Urinary diversion was performed using j-j stent and PCN in 64 and 8 patients, respectively. Preoperative prophylactic antibiotics were administered routinely. Bacteriological testing of urine was carried out using an extended set (9-10) of culture media. Empirical antibiotic therapy was initiated only after the restoration of urine outflow from the kidney and continued for 5-6 days until the availability of bacteriological testing results. Levels of bacteriuria with Enterobacteria, gram-positive pathogens and NAB in two urine samples did not differ significantly (p>0.05). There was a wide range of bacteriuria from 101 to 106 CFU/ml of most microorganisms except @Proteus spp., S. aureus. In bladder urine, the rates of bacteriuria of more or equal 104 CFU/ml for E. coli, Klebsiella spp. and Proteus spp. were 90.9%, 72.7% and 100.0%, respectively. For the remaining microorganisms, predominant bacteriuria was less or equal 103 CFU/ml. In pelvic urine, the rates of bacteriuria of more or equal 104 CFU/ml for E. coli, Klebsiella spp. and Proteus spp. was 71.8%, 40.0% and 66.7%, respectively. Other uropathogens in the pelvic urine mainly had a bacterial count of less or equal 103 CFU/ml. Only the concentration of Corynebacterium spp. in the pelvic urine significantly (p=0.023) differed from that of the bladder urine. There were no significant differences between microbiota of bladder and pelvic urine depending on duration of OOP except higher rates of Corynebacterium spp. in the bladder urine.

  7. Kidney Tests

    MedlinePlus

    ... taking out waste products and making urine. Kidney tests check to see how well your kidneys are working. They include blood, urine, and imaging tests. Early kidney disease usually does not have signs ...

  8. [A study of biomechanical method for urine test based on color difference estimation].

    PubMed

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Zhou, Fengkun

    2008-02-01

    The biochemical analysis of urine is an important inspection and diagnosis method in hospitals. The conventional method of urine analysis covers mainly colorimetric visual appraisement and automation detection, in which the colorimetric visual appraisement technique has been superseded basically, and the automation detection method is adopted in hospital; moreover, the price of urine biochemical analyzer on market is around twenty thousand RMB yuan (Y), which is hard to enter into ordinary families. It is known that computer vision system is not subject to the physiological and psychological influence of person, its appraisement standard is objective and steady. Therefore, according to the color theory, we have established a computer vision system, which can carry through collection, management, display, and appraisement of color difference between the color of standard threshold value and the color of urine test paper after reaction with urine liquid, and then the level of an illness can be judged accurately. In this paper, we introduce the Urine Test Biochemical Analysis method, which is new and can be popularized in families. Experimental result shows that this test method is easy-to-use and cost-effective. It can realize the monitoring of a whole course and can find extensive applications.

  9. Study of removal of ammonia from urine vapor by dual catalyst

    NASA Technical Reports Server (NTRS)

    Budininkas, P.

    1976-01-01

    The feasibility of ammonia removal from urine vapor by a low temperature dual-catalyst system was investigated. The process is based on the initial catalytic oxidation of ammonia present in urine vapor to nitrogen and nitrous oxide, followed by a catalytic decomposition of the nitrous oxide formed into its elements. The most active catalysts for the oxidation of ammonia and for the decomposition of N2O, identified in screening tests, were then combined into dual catalyst systems and tested to establish their overall efficiencies for the removal of ammonia from artificial gas mixtures. Dual catalyst systems capable of ammonia removal from the artificial gas mixtures were then tested with the actual urine vapor produced by boiling untreated urine. A suitable dual catalyst bed arrangement was found that achieved the removal of ammonia and organic carbon, and recovered water of good quality from urine vapor.

  10. Development and validation of a highly sensitive urine-based test to identify patients with colonic adenomatous polyps.

    PubMed

    Wang, Haili; Tso, Victor; Wong, Clarence; Sadowski, Dan; Fedorak, Richard N

    2014-03-20

    Adenomatous polyps are precursors of colorectal cancer; their detection and removal is the goal of colon cancer screening programs. However, fecal-based methods identify patients with adenomatous polyps with low levels of sensitivity. The aim or this study was to develop a highly accurate, prototypic, proof-of-concept, spot urine-based diagnostic test using metabolomic technology to distinguish persons with adenomatous polyps from those without polyps. Prospective urine and stool samples were collected from 876 participants undergoing colonoscopy examination in a colon cancer screening program, from April 2008 to October 2009 at the University of Alberta. Colonoscopy reference standard identified 633 participants with no colonic polyps and 243 with colonic adenomatous polyps. One-dimensional nuclear magnetic resonance spectra of urine metabolites were analyzed to define a diagnostic metabolomic profile for colonic adenomas. A urine metabolomic diagnostic test for colonic adenomatous polyps was established using 67% of the samples (un-blinded training set) and validated using the other 33% of the samples (blinded testing set). The urine metabolomic diagnostic test's specificity and sensitivity were compared with those of fecal-based tests. Using a two-component, orthogonal, partial least-squares model of the metabolomic profile, the un-blinded training set identified patients with colonic adenomatous polyps with 88.9% sensitivity and 50.2% specificity. Validation using the blinded testing set confirmed sensitivity and specificity values of 82.7% and 51.2%, respectively. Sensitivities of fecal-based tests to identify colonic adenomas ranged from 2.5 to 11.9%. We describe a proof-of-concept spot urine-based metabolomic diagnostic test that identifies patients with colonic adenomatous polyps with a greater level of sensitivity (83%) than fecal-based tests.

  11. The Impact of Using Different Methods to Assess Completeness of 24-Hour Urine Collection on Estimating Dietary Sodium.

    PubMed

    Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard

    2016-06-01

    The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted. ©2015 Wiley Periodicals, Inc.

  12. Urinary lithogenesis risk tests: comparison of a commercial kit and a laboratory prototype test.

    PubMed

    Grases, Félix; Costa-Bauzá, Antonia; Prieto, Rafel M; Arrabal, Miguel; De Haro, Tomás; Lancina, Juan A; Barbuzano, Carmen; Colom, Sergi; Riera, Joaquín; Perelló, Joan; Isern, Bernat; Sanchis, Pilar; Conte, Antonio; Barragan, Fernando; Gomila, Isabel

    2011-11-01

    Renal stone formation is a multifactorial process depending in part on urine composition. Other parameters relate to structural or pathological features of the kidney. To date, routine laboratory estimation of urolithiasis risk has been based on determination of urinary composition. This process requires collection of at least two 24 h urine samples, which is tedious for patients. The most important feature of urinary lithogenic risk is the balance between various urinary parameters, although unknown factors may be involved. The objective of this study was to compare data obtained using a commercial kit with those of a laboratory prototype, using a multicentre approach, to validate the utility of these methods in routine clinical practice. A simple new commercial test (NefroPlus®; Sarstedt AG & Co., Nümbrecht, Germany) evaluating the capacity of urine to crystallize calcium salts, and thus permitting detection of patients at risk for stone development, was compared with a prototype test previously described by this group. Urine of 64 volunteers produced during the night was used in these comparisons. The commercial test was also used to evaluate urine samples of 83 subjects in one of three hospitals. Both methods were essentially in complete agreement (98%) with respect to test results. The multicentre data were: sensitivity 94.7%; specificity 76.9%; positive predictive value (lithogenic urine) 90.0%; negative predictive value (non-lithogenic urine) 87.0%; test efficacy 89.2%. The new commercial NefroPlus test offers fast and cheap evaluation of the overall risk of development of urinary calcium-containing calculi.

  13. Hair and urine testing to assess drugs of abuse consumption in couples undergoing assisted reproductive technology (ART).

    PubMed

    Pichini, Simona; De Luca, Roberto; Pellegrini, Manuela; Marchei, Emilia; Rotolo, Maria Concetta; Spoletini, Roberta; D'Aloja, Paola; Pacifici, Roberta; Mortali, Claudia; Scaravelli, Giulia

    2012-05-10

    For the first time in Europe hair and urine testing have been applied to assess drugs of abuse consumption in couples undergoing assisted reproductive technology and the eventual association of toxic habits with other lifestyle, health status and sociodemographic factors was also investigated. Couples attending five assisted reproduction centers in Rome were invited to join the study. When they presented at the Centre for the visit, they were asked to answer a structured questionnaire concerning sociodemographic characteristics and lifestyle habits, and at the same time to provide hair and urine samples. Hair and urine testing for drugs of abuse, urinary profile of principal endogenous steroids involved in fertility process (testosterone, epitestosterone, androsterone, etiocholanolone and dehydroepiandrosterone) and of alcohol and tobacco smoke biomarkers were performed with validated methodologies. Of the 594 enrolled individuals (297 couples), 352 (164 couples and 24 single individuals from the couple) completed the questionnaire and gave both hair and urine samples, apart from 3 bald men, who only gave urine samples. Urine testing showed an overall 4.8% (17 individuals) positivity to drugs of abuse: 4.2% to cannabinoids, 1.4% to cocaine and 0.85% to both drugs. Results of 4cm segment hair samples testing matched those from urine samples. Thus, taking together, results of urine and hair testing confirmed repeated use of cannabis, cocaine and both drugs in 3.7, 0.85 and 0.57% examined individuals, respectively. Drug consumers were in a statistically higher percentage active smokers and alcohol drinkers, less prone to physical activity and with a trend towards higher weight than non consumers. Finally, repeated drug consumption was associated with significant lower concentration of urinary testosterone in males and of urinary dehydroepiandrosterone in females. The findings of the present study confirm the suitability of urine testing to disclose recent drugs of abuse consumption and of hair analysis to verify repeated consumption. Association between different toxic habits and sedentary lifestyle is also substantiated by the obtained results in our cohort of couples attending assisted reproduction centers. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. Quantitative urine confirmatory testing for synthetic cannabinoids in randomly collected urine specimens

    PubMed Central

    Castaneto, Marisol S.; Scheidweiler, Karl B.; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L.; Martin, Thomas M.; Huestis, Marilyn A.

    2014-01-01

    Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20,017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1,432 presumptive positive specimens. We analyzed all presumptive positive and 1,069 negative specimens with our qualitative synthetic cannabinoid LC-MS/MS method, which confirmed 290 positive specimens. All 290 positive and 487 randomly-selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date. 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-018 N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1–2434), 5.1 (0.1–1239), 2.0 (0.1–321), 1.1 (0.1–48.6), and 1.1 (0.1–250) μg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although, hydroxyindoles also were observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. PMID:25231213

  15. Bladder Diseases

    MedlinePlus

    ... frequent, urgent urination Bladder cancer Doctors diagnose bladder diseases using different tests. These include urine tests, x- ... National Institute of Diabetes and Digestive and Kidney Diseases

  16. Comparison of sodium, potassium, calcium, magnesium, zinc, copper and iron concentrations of elements in 24-h urine and spot urine in hypertensive patients with healthy renal function.

    PubMed

    Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi

    2017-12-01

    Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.

  17. Kinetic and Mechanistic Studies of the Deuterium Exchange in Classical Keto-Enol Tautomeric Equilibrium Reactions

    ERIC Educational Resources Information Center

    Nichols, Michael A.; Waner, Mark J.

    2010-01-01

    An extension of the classic keto-enol tautomerization of beta-dicarbonyl compounds into a kinetic analysis of deuterium exchange is presented. It is shown that acetylacetone and ethyl acetoacetate undergo nearly complete deuterium exchange of the alpha-methylene carbon when dissolved in methanol-d[subscript 4]. The extent of deuteration may be…

  18. Role of Urine Drug Testing in the Current Opioid Epidemic.

    PubMed

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  19. Enhanced urinalysis in the detection of asymptomatic bacteriuria in pregnancy.

    PubMed

    Aigere, E O S; Okusanya, B O; Eigbefoh, J O; Okome, G B O

    2013-01-01

    Detection and treatment of asymptomatic bacteriuria (ASB) in pregnancy is important to avert the attendant maternal and fetal morbidity. Other than urine culture, no other screening test is unequivocal. The use of enhanced urinalysis test to detect ASB in pregnancy was investigated. This was a prospective observational study which compared enhanced urinalysis with dipstick tests and urine culture. Clean catch midstream urine specimen was collected from 150 consecutive asymptomatic pregnant women. Tests of validity were used for comparison. Enhanced urinalysis detected bacteriuria as much as urine culture (4% vs. 4.7%). Itwas 57.1% sensitive and 98.6% specific. It had a false negative rate of 42.9% and was 96.7% accurate when compared to urine culture. Enhanced urinalysis took 1-2 hours to be done and required skills to use the microscope and was more expensive than dipstick urinalysis. The accuracy of enhanced urinalysis and its ability to detect ASB as much as urine culture connotes that it can be used to detect asymptomatic bacteriuria in pregnancy albeit only in secondary and tertiary health centres because of the cost and technicality involved.

  20. Dipstick screening for urinary tract infection in febrile infants.

    PubMed

    Glissmeyer, Eric W; Korgenski, E Kent; Wilkes, Jacob; Schunk, Jeff E; Sheng, Xiaoming; Blaschke, Anne J; Byington, Carrie L

    2014-05-01

    This study compares the performance of urine dipstick alone with urine microscopy and with both tests combined as a screen for urinary tract infection (UTI) in febrile infants aged 1 to 90 days. We queried the Intermountain Healthcare data warehouse to identify febrile infants with urine dipstick, microscopy, and culture performed between 2004 and 2011. UTI was defined as >50 000 colony-forming units per milliliter of a urinary pathogen. We compared the performance of urine dipstick with unstained microscopy or both tests combined ("combined urinalysis") to identify UTI in infants aged 1 to 90 days. Of 13 030 febrile infants identified, 6394 (49%) had all tests performed and were included in the analysis. Of these, 770 (12%) had UTI. Urine culture results were positive within 24 hours in 83% of UTIs. The negative predictive value (NPV) was >98% for all tests. The combined urinalysis NPV was 99.2% (95% confidence interval: 99.1%-99.3%) and was significantly greater than the dipstick NPV of 98.7% (98.6%-98.8%). The dipstick positive predictive value was significantly greater than combined urinalysis (66.8% [66.2%-67.4%] vs 51.2% [50.6%-51.8%]). These data suggest 8 febrile infants would be predicted to have a false-positive combined urinalysis for every 1 infant with UTI initially missed by dipstick screening. Urine dipstick testing compares favorably with both microscopy and combined urinalysis in febrile infants aged 1 to 90 days. The urine dipstick test may be an adequate stand-alone screen for UTI in febrile infants while awaiting urine culture results. Copyright © 2014 by the American Academy of Pediatrics.

  1. Performance evaluation of three on-site adulterant detection devices for urine specimens.

    PubMed

    Peace, Michelle R; Tarnai, Lisa D

    2002-10-01

    The performance of three on-site adulterant detection devices that assess the integrity of urine specimens collected for drug-of-abuse testing was evaluated: the Intect 7, MASK Ultra Screen, and Adultacheck 4. Intect 7 simultaneously tests creatinine, nitrite, glutaraldehyde, pH, specific gravity, and the presence of bleach and pyridinium chlorochromate (PCC). Mask Ultra Screen tests creatinine, nitrite, pH, specific gravity, and oxidants, and Adultacheck 4 tests creatinine, nitrite, glutaraldehyde, and pH. Urine specimens were prepared with the Substance Abuse and Mental Health Administration regulated analytes at 50% above the cut-off concentrations. Stealth, Urine Luck, Instant Clean ADD-IT-ive, and KLEAR were added individually to the drug-added urine specimens so that their concentrations reflected the "optimum" usage reported in their package inserts and 25% above and below that optimum. Stealth is reported to be peroxidase; Urine Luck is believed to be PCC; Instant Clean ADD-it-ive reportedly contains glutaraldehyde, and Klear is a nitrite. The following diluents/adulterants were added at 25%, 33%, and 50% of the volume of drug-added urine: distilled water, bleach, ammonia, and vinegar. Of the devices tested, Intect 7 proved to be the most sensitive, and it correctly indicated the presence of adulterant or diluent in all samples tested. In order to do so, all indication pads had to be assessed in concert. Adultacheck 4 specifically assesses four characteristics of urine integrity and is therefore very limited in detecting the use of several popular adulterants that are commercially available. Although it correctly assessed the four characteristics, it did not detect the use of Stealth, Urine Luck, or Instant Clean ADD-it-ive. Mask Ultra Screen can potentially detect a broader range of adulterants than Adultacheck 4. However, in practice, it only detected them at levels well above their optimum usage, making it less efficacious than Intect 7. Clearly, the specific identification of an adulterant is a trade-off for sensitive detection of several adulterants.

  2. Adulteration of urine by "Urine Luck".

    PubMed

    Wu, A H; Bristol, B; Sexton, K; Cassella-McLane, G; Holtman, V; Hill, D W

    1999-07-01

    In vitro adulterants are used to invalidate assays for urine drugs of abuse. The present study examined the effect of pyridinium chlorochromate (PCC) found in the product "Urine Luck". PCC was prepared and added to positive urine controls at concentrations of 0, 10, 50, and 100 g/L. The controls were assayed for methamphetamine, benzoylecgonine (BE), codeine and morphine, tetrahydrocannabinol (THC), and phencyclidine (PCP) with the Emit II (Syva) and Abuscreen Online (Roche) immunoassays, and by gas chromatography/mass spectrometry (GC/MS). Two tests were also developed to detect PCC in urine: a spot test to detect chromate ions using 10 g/L 1,5-diphenylcarbazide as the indicator, and a GC/MS assay for pyridine. We tested 150 samples submitted for routine urinalysis, compliance, and workplace drug testing for PCC, using these assays. Response rates decreased at 100 g/L PCC for all Emit II drug assays and for the Abuscreen morphine and THC assays. In contrast, the Abuscreen amphetamine assay produced apparently higher results, and no effect was seen on the results for BE or PCP. The PCC did not affect the GC/MS recovery of methamphetamine, BE, PCP, or their deuterated internal standards, but decreased GC/MS recovery of the opiates at both intermediate (50 g/L) and high (100 g/L) PCC concentrations and apparent concentrations of THC and THC-d3 at all PCC concentrations. Two of 50 samples submitted for workplace drug testing under chain-of-custody conditions were positive for PCC, whereas none of the remaining 100 specimens submitted for routine urinalysis or compliance drug testing were positive. PCC is an effective adulterant for urine drug testing of THC and opiates. Identification of PCC use can be accomplished with use of a spot test for the oxidant.

  3. Comparison of initial stream urine samples and cervical samples for detection of human papillomavirus.

    PubMed

    Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige

    2016-08-01

    Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  4. Diagnostic accuracy of a point-of-care urine test for tuberculosis screening among newly-diagnosed HIV-infected adults: a prospective, clinic-based study.

    PubMed

    Drain, Paul K; Losina, Elena; Coleman, Sharon M; Giddy, Janet; Ross, Douglas; Katz, Jeffrey N; Walensky, Rochelle P; Freedberg, Kenneth A; Bassett, Ingrid V

    2014-02-26

    A rapid diagnostic test for active tuberculosis (TB) at the clinical point-of-care could expedite case detection and accelerate TB treatment initiation. We assessed the diagnostic accuracy of a rapid urine lipoarabinomannan (LAM) test for TB screening among HIV-infected adults in a TB-endemic setting. We prospectively enrolled newly-diagnosed HIV-infected adults (≥18 years) at 4 outpatient clinics in Durban from Oct 2011-May 2012, excluding those on TB therapy. A physician evaluated all participants and offered CD4 cell count testing. Trained study nurses collected a sputum sample for acid-fast bacilli smear microscopy (AFB) and mycobacterial culture, and performed urine LAM testing using Determine™ TB LAM in the clinic. The presence of a band regardless of intensity on the urine LAM test was considered positive. We defined as the gold standard for active pulmonary TB a positive sputum culture for Mycobacterium tuberculosis. Diagnostic accuracy of urine LAM was assessed, alone and in combination with smear microscopy, and stratified by CD4 cell count. Among 342 newly-diagnosed HIV-infected participants, 190 (56%) were male, mean age was 35.6 years, and median CD4 was 182/mm3. Sixty participants had culture-positive pulmonary TB, resulting in an estimated prevalence of 17.5% (95% CI 13.7-22.0%). Forty-five (13.2%) participants were urine LAM positive. Mean time from urine specimen collection to LAM test result was 40 minutes (95% CI 34-46 minutes). Urine LAM test sensitivity was 28.3% (95% CI 17.5-41.4) overall, and 37.5% (95% CI 21.1-56.3) for those with CD4 count <100/mm3, while specificity was 90.1% (95% CI 86.0-93.3) overall, and 86.9% (95% CI 75.8-94.2) for those with CD4 < 100/mm3. When combined with sputum AFB (either test positive), sensitivity increased to 38.3% (95% CI 26.0-51.8), but specificity decreased to 85.8% (95% CI 81.1-89.7). In this prospective, clinic-based study with trained nurses, a rapid urine LAM test had low sensitivity for TB screening among newly-diagnosed HIV-infected adults, but improved sensitivity when combined with sputum smear microscopy.

  5. Lupus Nephritis

    MedlinePlus

    ... can be a sign of lupus nephritis. What tests do health care professionals use to diagnose lupus nephritis? Lupus nephritis ... and blood tests and a kidney biopsy. Urine Test Your health care professional uses a urine sample to look for ...

  6. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle R.; Broyan, James Lee, Jr.

    2011-01-01

    Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

  7. Fluorescence And Alternative Methods In Urine Drug Testing

    NASA Astrophysics Data System (ADS)

    Jain, Naresh C.

    1988-04-01

    Drug abuse has become-one of the most compelling realities _ ot contemporary society. It has penetrated every segment ot our population: trom schools to sports and trom organized crime to board rooms . Drugs in tie w9rkplace allegedly cost government agencies and business millions ot dollars each year in increased absenteeism,. poor work performance, thefts,accidents andwastedtime. The President's Commission on Organized Crime and the federal government are in tavor ot urine drug testing. In fact many employers are now resorting to urine drug testing on current and prospective employees. This presep.tation discusses different laboratory methods used in urine drug.testing, including immunoassays, fluorescence polarization, thin layer chromatography, high pressure liquid chromatography, gas chromatography and gas-chromatography-mass spectrometry.

  8. Evaluation of a Urine Pooling Strategy for the Rapid and Cost-Efficient Prevalence Classification of Schistosomiasis.

    PubMed

    Lo, Nathan C; Coulibaly, Jean T; Bendavid, Eran; N'Goran, Eliézer K; Utzinger, Jürg; Keiser, Jennifer; Bogoch, Isaac I; Andrews, Jason R

    2016-08-01

    A key epidemiologic feature of schistosomiasis is its focal distribution, which has important implications for the spatial targeting of preventive chemotherapy programs. We evaluated the diagnostic accuracy of a urine pooling strategy using a point-of-care circulating cathodic antigen (POC-CCA) cassette test for detection of Schistosoma mansoni, and employed simulation modeling to test the classification accuracy and efficiency of this strategy in determining where preventive chemotherapy is needed in low-endemicity settings. We performed a cross-sectional study involving 114 children aged 6-15 years in six neighborhoods in Azaguié Ahoua, south Côte d'Ivoire to characterize the sensitivity and specificity of the POC-CCA cassette test with urine samples that were tested individually and in pools of 4, 8, and 12. We used a Bayesian latent class model to estimate test characteristics for individual POC-CCA and quadruplicate Kato-Katz thick smears on stool samples. We then developed a microsimulation model and used lot quality assurance sampling to test the performance, number of tests, and total cost per school for each pooled testing strategy to predict the binary need for school-based preventive chemotherapy using a 10% prevalence threshold for treatment. The sensitivity of the urine pooling strategy for S. mansoni diagnosis using pool sizes of 4, 8, and 12 was 85.9%, 79.5%, and 65.4%, respectively, when POC-CCA trace results were considered positive, and 61.5%, 47.4%, and 30.8% when POC-CCA trace results were considered negative. The modeled specificity ranged from 94.0-97.7% for the urine pooling strategies (when POC-CCA trace results were considered negative). The urine pooling strategy, regardless of the pool size, gave comparable and often superior classification performance to stool microscopy for the same number of tests. The urine pooling strategy with a pool size of 4 reduced the number of tests and total cost compared to classical stool microscopy. This study introduces a method for rapid and efficient S. mansoni prevalence estimation through examining pooled urine samples with POC-CCA as an alternative to widely used stool microscopy.

  9. Evaluation of a Urine Pooling Strategy for the Rapid and Cost-Efficient Prevalence Classification of Schistosomiasis

    PubMed Central

    Coulibaly, Jean T.; Bendavid, Eran; N’Goran, Eliézer K.; Utzinger, Jürg; Keiser, Jennifer; Bogoch, Isaac I.; Andrews, Jason R.

    2016-01-01

    Background A key epidemiologic feature of schistosomiasis is its focal distribution, which has important implications for the spatial targeting of preventive chemotherapy programs. We evaluated the diagnostic accuracy of a urine pooling strategy using a point-of-care circulating cathodic antigen (POC-CCA) cassette test for detection of Schistosoma mansoni, and employed simulation modeling to test the classification accuracy and efficiency of this strategy in determining where preventive chemotherapy is needed in low-endemicity settings. Methodology We performed a cross-sectional study involving 114 children aged 6–15 years in six neighborhoods in Azaguié Ahoua, south Côte d’Ivoire to characterize the sensitivity and specificity of the POC-CCA cassette test with urine samples that were tested individually and in pools of 4, 8, and 12. We used a Bayesian latent class model to estimate test characteristics for individual POC-CCA and quadruplicate Kato-Katz thick smears on stool samples. We then developed a microsimulation model and used lot quality assurance sampling to test the performance, number of tests, and total cost per school for each pooled testing strategy to predict the binary need for school-based preventive chemotherapy using a 10% prevalence threshold for treatment. Principal Findings The sensitivity of the urine pooling strategy for S. mansoni diagnosis using pool sizes of 4, 8, and 12 was 85.9%, 79.5%, and 65.4%, respectively, when POC-CCA trace results were considered positive, and 61.5%, 47.4%, and 30.8% when POC-CCA trace results were considered negative. The modeled specificity ranged from 94.0–97.7% for the urine pooling strategies (when POC-CCA trace results were considered negative). The urine pooling strategy, regardless of the pool size, gave comparable and often superior classification performance to stool microscopy for the same number of tests. The urine pooling strategy with a pool size of 4 reduced the number of tests and total cost compared to classical stool microscopy. Conclusions/Significance This study introduces a method for rapid and efficient S. mansoni prevalence estimation through examining pooled urine samples with POC-CCA as an alternative to widely used stool microscopy. PMID:27504954

  10. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    PubMed

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  11. Point-of-care Helicobacter pylori urine antibody detection in a multi-ethnic adult population in the United States.

    PubMed

    Opekun, Antone R; Luu, Phong; Gotschall, Ann B; Abdalla, Nageeb; Torres, Elizabeth; Rudd, Summer B; Graham, David Y; Nurgalieva, Zhannat Z; Tsuchiya, Kyoko

    2006-07-01

    A need exists for accurate point-of-care tests for diagnosis of Helicobacter pylori (H. pylori) infection to evaluate a rapid urine-H. pylori antibody test device for detection of H. pylori infection in a point-of-care setting in the United States. A multi-center study in a multi-ethnic population compared the RAPIRUN urine antibody test with the (13)C-urea breath test (C-UBT) and a traditional serologic test, the high-molecular-weight cell-associated protein enzyme immunoassay (HM-CAP EIA). The primary comparator was with "definite positive" and "definite negative" patients defined as a concordance of combined results of the UBT and the HM-CAP IgG EIA. Overall, 188 eligible patients were enrolled (61 men, age range: 18-73 years, including 84 Hispanics, 73 Asian-Pacific Americans, 22 Black African-Americans, 6 non-Hispanic Caucasians, and 3 of "other" ethnicity). Compared with "definite positive" and "definite negative" results, the sensitivity and specificity of the urine antibody test were 0.9 and 1.0, respectively. The urine antibody test proved suitable for point-of-care rapid diagnosis of anti-H. pylori antibodies indicative of active or past H. pylori infection.

  12. Amylase - urine

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/003607.htm Amylase - urine To use the sharing features on this page, ... test that measures the amount of amylase in urine. Amylase is an enzyme that helps digest carbohydrates. ...

  13. Urinalysis in children and adolescents.

    PubMed

    Utsch, Boris; Klaus, Günter

    2014-09-12

    Urinalysis is the most commonly performed biochemical test in infancy and early childhood. The urine sample should be correctly obtained, age-specific aspects should be considered, and age-dependent reference values should be used. This review is based on a selective literature search in electronic databases, textbooks, and guidelines from Germany and abroad on the acquisition of urine samples and the performance of urinalysis in infancy and early childhood. The timing and mode of acquisition of the urine sample affect the assessment of hematuria, proteinuria, leukocyturia, nitrituria, and the uropathogenic bacterial colony count in the urine culture. Dipstick tests can be used for targeted screening for these features. The test results should be interpreted together with the findings of urine microscopy, the medical history, and the physical examination. Proteinuria should be quantified and differentiated; both of these things can be done either from collected urine or (especially in infants and young children) from a spontaneously voided urine sample, by determination of the protein/creatinine quotient. Orthostatic proteinuria in an adolescent requires no further evaluation or treatment. Hematuria should be characterized as either glomerular or non-glomerular erythrocyturia. Asymptomatic, isolated microhematuria in childhood is not uncommon and often transient; in the absence of a family history, it usually does not require an extensive work-up. Proteinuria combined with hematuria should arouse the suspicion of glomerulonephritis. Urinalysis in infancy and early childhood is a simple and informative diagnostic test as long as the urine sample has been obtained properly and the results are interpreted appropriately for this age group.

  14. High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.

    PubMed

    Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna

    2013-01-01

    Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.

  15. The Diagnostic Accuracy of Urine-Based Xpert MTB/RIF in HIV-Infected Hospitalized Patients Who Are Smear-Negative or Sputum Scarce

    PubMed Central

    Peter, Jonathan G.; Theron, Grant; Muchinga, Tapuwa E.; Govender, Ureshnie; Dheda, Keertan

    2012-01-01

    Background Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients. Methodology/Principal Findings 281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity). Conclusions/Significance This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity. PMID:22815718

  16. Multicenter Evaluation of the AMPLICOR and Automated COBAS AMPLICOR CT/NG Tests for Detection of Chlamydia trachomatis

    PubMed Central

    Van Der Pol, Barbara; Quinn, Thomas C.; Gaydos, Charlotte A.; Crotchfelt, Kimberly; Schachter, Julius; Moncada, Jeanne; Jungkind, D.; Martin, David H.; Turner, Buffy; Peyton, Cynthia; Jones, Robert B.

    2000-01-01

    The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for the ability to detect Chlamydia trachomatis infections. Test performance compared to that of culture was evaluated for 2,236 matched endocervical swab and urine specimens obtained from women and for 1,940 matched urethral swab and urine specimens obtained from men. Culture-negative, PCR-positive specimens that tested positive in a direct fluorescent-antibody test or in a confirmatory PCR test for an alternative target sequence were resolved as true positives. The overall prevalences of chlamydia were 2.4% in women and 7.2% in men. The COBAS AMPLICOR and AMPLICOR formats yielded concordant results for 98.1% of the specimens. With the infected patient as the reference standard, the resolved sensitivities of COBAS AMPLICOR were 89.7% for endocervical swab specimens, 89.2% for female urine specimens, 88.6% for male urethral swab specimens, and 90.3% for male urine specimens. When results were analyzed as if only a single test had been performed on a single specimen type, the resolved sensitivity was always higher. The resolved specificities of PCR were 99.4% for endocervical swab specimens, 99.0% for female urine specimens, 98.7% for male urethral swab specimens, and 98.4% for male urine specimens. The internal control revealed that 2.4% of the specimens were inhibitory when initially tested. Nevertheless, valid results were obtained for 98.6% of the specimens because 59.1% of the inhibitory specimens were not inhibitory when a second aliquot was tested. The COBAS AMPLICOR and AMPLICOR CT/NG tests for C. trachomatis exhibited equally high sensitivity and specificity with both urogenital swab and urine specimens and thus are well suited for screening for C. trachomatis infection. PMID:10699004

  17. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    PubMed

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  18. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...

  19. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...

  20. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...

  1. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...

  2. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...

  3. [USING URINARY STRIPS].

    PubMed

    Barbeito García, Ana; Sampayo Montenegro, Ana

    2015-10-01

    Urinalysis using reactive strip is a commonly used in clinical practice. Although mainly indicated as first step test when a urine infection it suspected, it may also be a helpful tool in the management of a wide range of disorders. Standard urine test strips may comprise of up to 10 different chemical pads or reagents (leukocytes, nitrites, pH, glucose, proteins, ketones, bilirubin, urobilinogen, density and blood) that allow a qualitative and semiquantitative analysis of a urine sample. The test method consists of immersing the strip completely in a well-mixed sample of urine and left to stand for the time necessary for the reactions to occur (which is variable depending on the manufacturer). Finally the colors that appear are compared against a specific chromatic scale provided. Several factors may influence the results causing a significant number of false positives and negatives. Such limitations should always be taken into account when reading the test. Despite clinical features lead to the suspicion of an infection, urine test strips is a fast screening test that may reinforce the diagnosis. The combination of dysuria, frequency and emergency, hematuria, pain and sensibility in the pelvis reaches a positive predictive value to identified a urine infection of 90 %. When only dysuria and emergency or high frequency are present, the such probability diminishes to 70-80%, and, when dysuria is the only symptom, it drops to 25%. Despite urine test strips is a fast, easy and cheap method for the diagnosis and follow-up of several diseases, results are fairly heterogeneous and may be influenced by external factors. Therefore a cautious interpretation if advised. Sensibility and specificity of urine test strips is widely variable (S 46%-86% and E 17%-93%). Although the highest diagnostic values are obtained at primary care centers, where such tests are routinely used in a diverse population, the number of false positives is still high. This issue should be taken into account and a proper differential diagnosis of a positive result is mandatory in all cases. More studies are needed to assess the real sensibility and specificity of urinary reactive strips.

  4. Urine Cytology

    MedlinePlus

    ... types of cells were found in your urine sample. You may need to repeat the test. Negative. This means no cancer cells were identified in your urine sample. Atypical. This indicates that some abnormalities were found ...

  5. CK (Creatine Kinase) Test

    MedlinePlus

    ... you have muscle weakness, muscle aches, and/or dark urine and your healthcare practitioner suspects muscle damage; ... such as: Muscle pain or aches Muscle weakness Dark urine (The urine may be dark because of ...

  6. Creatinine

    MedlinePlus

    ... then passes out of the body in your urine. If you have kidney disease, the level of creatinine in your blood increases. Blood (serum) and urine tests can check your creatinine levels. The tests ...

  7. Diagnostic value and cost utility analysis for urine Gram stain and urine microscopic examination as screening tests for urinary tract infection.

    PubMed

    Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn

    2005-06-01

    The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.

  8. Microbiological test results using three urine pretreatment regimes with 316L stainless steel

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1993-01-01

    Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.

  9. HMGCS2 promotes autophagic degradation of the amyloid-β precursor protein through ketone body-mediated mechanisms.

    PubMed

    Hu, Li-Tian; Zhu, Bing-Lin; Lai, Yu-Jie; Long, Yan; Zha, Jing-Si; Hu, Xiao-Tong; Zhang, John H; Chen, Guo-Jun

    2017-04-29

    HMGCS2 (mitochondrial 3-hydroxy-3-methylglutaryl-COA synthase 2) is a control enzyme in ketogenesis. The mitochondrial localization and interaction with APP (β-amyloid precursor protein) suggest that HMGCS2 may play a role in the pathophysiology of AD (Alzheimer's disease). Here we report that overexpression of HMGCS2 decreased levels of APP and related CTFs (carboxy-terminal fragments), which was largely prevented by an autophagic inhibitor chloroquine. In addition, HMGCS2 enhancement of autophagic marker LC3II was diminished by rapamycin, an inhibitor of mechanistic target of rapamycin. Moreover, deprivation of EBSS (Earle's Balanced Salt Solution) significantly augmented the effect of HMGCS2 on LC3II, while acetoacetate reversed the reduction of LC3II, APP and CTFs which was induced by HMGCS2 knockdown. In the presence of acetoacetate, rapamycin failed to induce further increase of LC3II, which mimicked the effect of HMGCS2 overexpression. Finally, HMGCS2 enhanced the antioxidant response. Collectively, HMGCS2 shares with ketone bodies common features in autophagic clearance of APP and CTFs, suggesting that ketone bodies play an important role in HMGCS2 regulation of the autophagy. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Urine Creatinine Concentrations in Drug Monitoring Participants and Hospitalized Patients.

    PubMed

    Love, Sara A; Seegmiller, Jesse C; Kloss, Julie; Apple, Fred S

    2016-10-01

    Urine drug testing is commonly performed in both clinical and forensic arenas for screening, monitoring and compliance purposes. We sought to determine if urine creatinine concentrations in monitoring program participants were significantly different from hospital in-patients and out-patients undergoing urine drug testing. We retrospectively reviewed urine creatinine submitted in June through December 2015 for all specimens undergoing urine drug testing. The 20,479 creatinine results were categorized as hospitalized patients (H) and monitoring/compliance groups for pain management (P), legal (L) or recovery (R). Median creatinine concentrations (interquartile range, mg/dL) were significantly different (P < 0.001) between groups: H 126 (122-136); P 138 (137-143); L 147 (144-154); R 95 (92-97). In the two groups subject to on-demand sampling time pressures, median creatinine concentrations were significantly lower in the R vs. L group (P<0.001). In conclusion, recovery (R) participants have more dilute specimens, reflected by significantly lower creatinine concentration and may indicate participants' attempts to tamper with their drug test results through dilution means. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Getting a Urine Test (For Kids)

    MedlinePlus Videos and Cool Tools

    ... learn a lot from urine tests. Obviously, this test doesn't hurt. And if you know what to expect, it doesn't have to be embarrassing ... Visit the Nemours Web site. Note: All information on KidsHealth® is for ...

  12. Nitrogen test (image)

    MedlinePlus

    ... is performed to check for the amount of urea in urine. Urine is collected over a 24 hour period and is sent to the laboratory for testing. This test is mainly used to assess the amount of dietary protein needed by severely ill patients.

  13. Evaluation of the automated urine particle analyzer UF-1000i screening for urinary tract infection in nonpregnant women.

    PubMed

    Dai, Qingkai; Jiang, Yongmei; Shi, Hua; Zhou, Wei; Zhou, Shengjie; Yang, Hui

    2014-01-01

    Urinary tract infection (UTI) is a widespread disease in women. Urine culture is still the "gold standard" diagnostic test for UTI, but most of them are negative. To reduce unnecessary culture, we evaluated the automated urine particle analyzer UF-1000i screening for UTI in nonpregnant women. The urine specimens submitted to our laboratory were submitted for culture and tested by the Sysmex UF-1000i. Bacteria and white blood cell (WBC) counts were compared to standard urine culture results to assess the best cutoff values. In this study, 272 urine samples were included, of which 98 (36.0%) were culture positive with a bacterial cutoff value of 10 x 10(5) CFU/mL. A combination of bacterial (> 95/microL) and/or WBC count (> 24/microL) provided the best screening for UTI, with a sensitivity of 0.99 and a specificity of 0.82 compared with the urine culture. Sysmex UF-1000i could be used as a screening test for UTI in nonpregnant women. According to the distribution and range of the bacterial scattergram, we could primarily identify and differentiate between Gram-negative and Gram-positive bacteria.

  14. Non-invasive Pregnancy Diagnosis from Urine by the Cuboni Reaction and the Barium Chloride Test in Donkeys (Equus asinus) and Alpacas (Vicugna pacos).

    PubMed

    Kubátová, A; Fedorova, T; Skálová, I; Hyniová, L

    2016-09-01

    The aim of the research was to evaluate two chemical tests for non-invasive pregnancy diagnosis from urine, the Cuboni reaction and the barium chloride test, in donkeys (Equus asinus) and alpacas (Vicugna pacos). The research was carried out from April 2013 to September 2014. Urine samples were collected on five private Czech farms from 18 jennies and 12 alpaca females. Urine was collected non-invasively into plastic cups fastened on a telescopic rod, at 6-9 week intervals. In total, 60 and 54 urine samples from alpacas and jennies, respectively, were collected. The Cuboni reaction was performed by the State Veterinary Institute Prague. The barium chloride test was done with 5 ml of urine mixed together with 5 ml of 1% barium chloride solution. Results of the Cuboni reaction were strongly influenced by the reproductive status of jennies; the test was 100% successful throughout the second half of pregnancy. However, no relationship was found between the real reproductive status of alpaca females and results of the Cuboni reaction. It was concluded that the barium chloride test is not suitable for pregnancy diagnosis either in donkeys, due to significant influence of season on the results, or in alpacas, because no relationship between results of the test and the reproductive status of alpaca females was found. In conclusion, the Cuboni reaction has potential to become a standard pregnancy diagnostic method in donkeys.

  15. Quantitative urine confirmatory testing for synthetic cannabinoids in randomly collected urine specimens.

    PubMed

    Castaneto, Marisol S; Scheidweiler, Karl B; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L; Martin, Thomas M; Huestis, Marilyn A

    2015-06-01

    Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20 017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1432 presumptive positive specimens. We analyzed all presumptive positive and 1069 negative specimens with our qualitative synthetic cannabinoid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, which confirmed 290 positive specimens. All 290 positive and 487 randomly selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date; 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1-2,434), 5.1 (0.1-1,239), 2.0 (0.1-321), 1.1 (0.1-48.6), and 1.1 (0.1-250) µg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although hydroxyindoles were also observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. This article is a U.S. Government work and is in the public domain in the USA.

  16. EDRN Pre-Validation of Multiplex Biomarker in Urine — EDRN Public Portal

    Cancer.gov

    The goal of this proposal is to begin to establish an EDRN “pre-validation” trial of a multiplex set of transcripts, including the ETS gene fusions, in post-DRE urine sediments. As can be evidenced by our preliminary data, we have established the utility of this multiplex urine test (which includes TMPRSS-ERG, SPINK1, PCA3 and GOLPH2) in a cohort of prospectively collected urine sediments from the University of Michigan EDRN CEVC site (collected by co-I, Dr. John Wei). In this proposal, we will run this multiplex assay on prospectively collected post-DRE urines collected from other EDRN sites. The idea is to couple this “pre-validation” study with an EDRN validation trial under consideration for the Gen-Probe PCA3 urine test (directed by Drs. John Wei and Harry Rittenhouse).

  17. Pregnancy test

    MedlinePlus

    For the urine test, you urinate into a cup. For the blood test, the health care provider uses a needle and syringe to draw blood from your vein into a tube. Any discomfort you might feel from the blood draw will only last a few seconds.

  18. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  19. Usefulness of enzyme immunoassay (EIA) for screening of anti HIV antibodies in urinary specimens: A comparative analysis.

    PubMed

    Sahni, A K; Nagendra, A; Roy, Partha; Patrikar, S

    2014-07-01

    Standard HIV testing is done using serum or plasma. FDA approved ELISA to screen urine for IgG antibodies to HIV-1 in 1996. It is a simple, noninvasive test and is appropriate for developing countries where health care personnel may not be professionally trained or where clean needles for drawing blood may not always be available. 436 individuals with high-risk behavior and strong clinical suspicion of HIV infection were screened for IgG antibodies to HIV-1 in urine by ELISA. Urine HIV testing was performed by enzyme immunoassay, at the ongoing Voluntary Confidential Counseling and Testing Center (VCCTC) at a large tertiary care microbiology lab. The individuals enrolled for the study had high-risk exposure to the virus and majorities were from a state with a high incidence of HIV infection. In all individuals, both serum and urine were tested for IgG antibodies to HIV-1. Overall, 135 individuals (30.96%) were HIV-positive, of whom 96 (71%) had never previously tested positive; 87% of those who tested positive received their results, and most were referred for medical care. Sensitivity, specificity and predictive values of HIV-1 urine ELISA test kit were determined. Sensitivity was found to be 89.6%; 95% CI [82.9-94.0], specificity 97.3%; 95% CI [94.6-98.8], positive predictive value 93.8%; 95% CI [87.8-97.1] and negative predictive value 95.4%; 95% CI [92.3-97.4]. Efficiency, sensitivity, and specificity of the urine-based screening for HIV-1 test kits were excellent as compared to the reference test.

  20. A pilot study on the use of natural calcium isotope (44Ca/40Ca) fractionation in urine as a proxy for the human body calcium balance.

    PubMed

    Heuser, Alexander; Eisenhauer, Anton

    2010-04-01

    We explored the possibility of using natural calcium (Ca) isotope variations in the urine (delta(44/40)Ca(urine)) as a proxy for the Ca balance in the human body. We chose two test persons extremely different in their health status, gender and age (4-year-old healthy boy and a 60-year-old woman known to suffer from osteoporosis). During a 5 day interval the Ca isotope composition of the individual diet (delta(44/40)Ca(diet)) was monitored for both test persons to be in general agreement to the Ca isotope composition of the normal western European diet ( approximately -1.02+/-0.1 per thousand). However, measurements showed that (1) delta(44/40)Ca(urine) of both test persons are approximately 1.37 and approximately 2.49 per thousand, respectively, heavier than delta(44/40)Ca(diet) and that (2) the delta(44/40)Ca(urine-boy) is approximately 1.1 per thousand heavier when compared to the value of the woman. The individual offset between diet and test persons is interpreted to reflect individual Ca reabsorption rates in the kidneys being the result of Rayleigh type Ca isotope fractionation related to the partitioning of Ca between the glomerular filtrate and filtered residue. The relative difference between delta(44/40)Ca(urine-boy) and delta(44/40)Ca(urine-woman) of approximately 1.1 per thousand may reflect individual differences in the balance of bone mineralization and demineralization processes related to age, gender and health status. By arbitrarily defining an equilibrium value for Delta(44/40)Ca(diet-urine) of -1.93 per thousand being the arithmetic mean of delta(44/40)Ca(urine) for both test persons the measured delta(44/40)Ca(urine) values may be applied to model the individual bone mineralization and demineralization processes in a qualitative way. Note, second order influences of intestinal Ca absorption during sequestration of Ca between intestine and blood have to be subject of further studies. Copyright 2009 Elsevier Inc. All rights reserved.

  1. Urine Concentration and Pyuria for Identifying UTI in Infants.

    PubMed

    Chaudhari, Pradip P; Monuteaux, Michael C; Bachur, Richard G

    2016-11-01

    Varying urine white blood cell (WBC) thresholds have been recommended for the presumptive diagnosis of urinary tract infection (UTI) among young infants. These thresholds have not been studied with newer automated urinalysis systems that analyze uncentrifuged urine that might be influenced by urine concentration. Our objective was to determine the optimal urine WBC threshold for UTI in young infants by using an automated urinalysis system, stratified by urine concentration. Retrospective cross-sectional study of infants aged <3 months evaluated for UTI in the emergency department with paired urinalysis and urine culture. UTI was defined as ≥50 000 colony-forming units/mL from catheterized specimens. Test characteristics were calculated across a range of WBC and leukocyte esterase (LE) cut-points, dichotomized into specific gravity groups (dilute <1.015; concentrated ≥1.015). Twenty-seven thousand infants with a median age of 1.7 months were studied. UTI prevalence was 7.8%. Optimal WBC cut-points were 3 WBC/high-power field (HPF) in dilute urine (likelihood ratio positive [LR+] 9.9, likelihood ratio negative [LR‒] 0.15) and 6 WBC/HPF (LR+ 10.1, LR‒ 0.17) in concentrated urine. For dipstick analysis, positive LE has excellent test characteristics regardless of urine concentration (LR+ 22.1, LR‒ 0.12 in dilute urine; LR+ 31.6, LR‒ 0.22 in concentrated urine). Urine concentration should be incorporated into the interpretation of automated microscopic urinalysis in young infants. Pyuria thresholds of 3 WBC/HPF in dilute urine and 6 WBC/HPF in concentrated urine are recommended for the presumptive diagnosis of UTI. Without correction of specific gravity, positive LE by automated dipstick is a reliably strong indicator of UTI. Copyright © 2016 by the American Academy of Pediatrics.

  2. Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure

    PubMed Central

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2018-01-01

    Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162

  3. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    PubMed

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  4. [Mutagenic evaluation of the urine of rats treated with oils implicated in the toxic oil syndrome using bacterial tests].

    PubMed

    Barrueco, C; Sladek, F; Canga, C; Valcarce, E; de la Peña, E; Alia, M; Laborda, E

    1983-01-01

    The mutagenic activity of the urine of pregnant rats treated with toxic oil syndrome-related rape seed oil or with edible oil was evaluated by means of the Ames and Green tests. It was found that the urine of the pregnant rats treated with "Jen" oil, that was related to the toxic oil syndrome, was mutagenic.

  5. Comparison of Four Strong Acids on the Precipitation Potential of Gypsum in Brines During Distillation of Pretreated, Augmented Urine

    NASA Technical Reports Server (NTRS)

    Muirhead, Dean; Carrier, Christopher

    2012-01-01

    In this study, three different mineral acids were substituted for sulfuric acid (H2SO4) in the urine stabilizer solution to eliminate the excess of sulfate ions in pretreated urine and assess the impact on maximum water recovery to avoid precipitation of minerals during distillation. The study evaluated replacing 98% sulfuric acid with 85% phosphoric acid (H3PO4), 37% hydrochloric acid (HCl), or 70% nitric acid (HNO3). The effect of lowering the oxidizer concentration in the pretreatment formulation also was studied. This paper summarizes the test results, defines candidate formulations for further study, and specifies the injection masses required to stabilize urine and minimize the risk of mineral precipitation during distillation. In the first test with a brine ersatz acidified with different acids, the solubility of calcium in gypsum saturated solutions was measured. The solubility of gypsum was doubled in the brines acidified with the alternative acids compared to sulfuric acid. In a second series of tests, the alternative acid pretreatment concentrations were effective at preventing precipitation of gypsum and other minerals up to 85% water recovery from 95th-percentile pretreated, augmented urine. Based on test results, phosphoric acid is recommended as the safest alternative to sulfuric acid. It also is recommended that the injected mass concentration of chromium trioxide solution be reduced by 75% to minimize liquid resupply mass by about 50%, reduce toxicity of brines, and reduce the concentration of organic acids in distillate. The new stabilizer solution formulations and required doses to stabilize urine and prevent precipitation of minerals up to 85% water recovery are given. The formulations in this study were tested on a limited number of artificially augmented urine batches collected from employees at the Johnson Space Center (JSC). This study successfully demonstrated that the desired physical and chemical stability of pretreated urine and brines can be achieved using alternate pretreatment formulations under laboratory conditions. Additional testing and hazard assessments will be required to determine the feasibility of utilizing the proposed urine pretreatment formulations on ISS.

  6. Bilirubin in Urine: MedlinePlus Lab Test Information

    MedlinePlus

    ... Information → Bilirubin in Urine URL of this page: https://medlineplus.gov/labtests/bilirubininurine.html Bilirubin in Urine ... 2017 Mar 23]; [about 3 screens]. Available from: https://www.liverfoundation.org/for-patients/about-the-liver/ ...

  7. Urge incontinence

    MedlinePlus

    ... much urine you lost. Pelvic or abdominal ultrasound . Post void residual to measure the amount of urine left in your bladder after you urinate. Urinalysis to check for infection . Urinary stress test (you stand with a full bladder and cough). ...

  8. Monitoring hydration status pre- and post-training among university athletes using urine color and weight loss indicators.

    PubMed

    Webb, Marquitta C; Salandy, Sinead T; Beckford, Safiya E

    2016-01-01

    To investigate the hydration status pre- and post-training among university athletes using urine color and weight loss as indicators. Participants were 52 university athletes training for campus games in a developing country. Pre- and post-training urine specimens were compared with a standard urine color scale. Paired t tests were used to compare urine color and difference in body mass pre- and post-training. The mean age of the athletes was 22.87 ± 3.21. A statistically significance difference (p < .01) was observed between pre- (4.31 ± 1.75) and post- (5.67 ± 1.45) training urine color values for males. Hydration status and weight post-training were statistically significantly different both at the level of p < .01. The results suggest that there is a link between urine color and body mass difference among the student athletes tested. Exercise increases hypohydration due to fluid losses, and therefore attention should be given to fluid supplementation and individualization of fluid intake for each athlete.

  9. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  10. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  11. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  12. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  13. 75 FR 16813 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of [[Page 16814

  14. Advances in the Diagnosis of Human Opisthorchiasis: Development of Opisthorchis viverrini Antigen Detection in Urine

    PubMed Central

    Duenngai, Kunyarat; Wangboon, Chompunoot; Sithithaworn, Jiraporn; Watwiengkam, Nattaya; Namwat, Nisana; Techasen, Anchalee; Loilome, Watcharin; Yongvanit, Puangrat; Loukas, Alex; Sithithaworn, Paiboon; Bethony, Jeffrey M.

    2015-01-01

    Background Many strategies to control opisthorchiasis have been employed in Thailand, but not in the other neighbouring countries. Specific control methods include mass drug administration (MDA) and health education to reduce raw fish consumption. These control efforts have greatly shifted the epidemiology of Opisthorchis viverrini (OV) infection over the last decade from presenting as densely concentrated "heavy" infections in single villages to widespread "light" OV infections distributed over wide geographical areas. Currently, the "gold standard" detection method for OV infection is formalin ethyl-acetate concentration technique (FECT), which has limited diagnostic sensitivity and diagnostic specificity for light OV infections, with OV eggs often confused with eggs of minute intestinal flukes (MIFs) in feces. In this study, we developed and evaluated the diagnostic performance of a monoclonal antibody-based enzyme-linked immunosorbent assay for the measurement of OV excretory-secretory (ES) antigens in urine (urine OV-ES assay) for the diagnosis of opisthorchiasis compared to the gold standard detection FECT method. Methodology We tested several methods for pre-treating urine samples prior to testing the diagnostic performance of the urine OV-ES assay. Using trichloroacetic acid (TCA) pre-treated urine, we compared detection and quantification of OV infection using the urine OV-ES assay versus FECT in OV-endemic areas in Northeastern Thailand. Receiver operating characteristic (ROC) curves were used to determine the diagnostic sensitivity and specificity of the urine OV-ES assay using TCA pre-treated urine, and to establish diagnostic positivity thresholds. The Positive Predictive Value as well as the likelihood of obtaining a positive test result (LR+) or a negative test result (LR-) were calculated for the established diagnostic positivity threshold. Diagnostic risks (Odds Ratios) were estimated using logistic regression. Results When urine samples were pre-treated with TCA prior to use in the urine OV-ES assay, the analytical sensitivity was significantly improved. Using TCA pre-treatment of urine, the urine OV-ES assay had a limit of detection (LoD) of 39 ng/ml compared to the LoD of 52 ng/mL reported for coprological antigen detection methods. Similarly, the urine OV-ES assay correlated significantly with intensity of OV infection as measured by FECT. The urine OV-ES assay was also able to detect 28 individuals as positive from the 63 (44.4%) individuals previously determined to be negative using FECT. The likelihood of a positive diagnosis of OV infection by urine OV-ES assay increased significantly with the intensity of OV infection as determined by FECT. With reference to FECT, the sensitivity and specificity of the urine OV-ES assay was 81% and 70%, respectively. Conclusion The detection of OV-infection by the urine OV-ES assay showed much greater diagnostic sensitivity and diagnostic specificity than the current "gold standard" FECT method for the detection and quantification of OV infection. Due to its ease-of-use, and noninvasive sample collection (urine), the urine OV-ES assay offers the potential to revolutionize the diagnosis of liver fluke infection and provide an effective tool for control and elimination of these tumorigenic parasites. PMID:26485024

  15. 32 CFR 634.8 - Implied consent.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to blood, breath, or urine tests. Persons who drive on the installation shall be deemed to have given their consent to evidential tests for alcohol or other drug content of their blood, breath, or urine...

  16. Laboratory and clinical evaluation of on-site urine drug testing.

    PubMed

    Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter

    2014-11-01

    Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.

  17. Chronic Co-species Housing Mice and Rats Increased the Competitiveness of Male Mice.

    PubMed

    Liu, Ying-Juan; Li, Lai-Fu; Zhang, Yao-Hua; Guo, Hui-Fen; Xia, Min; Zhang, Meng-Wei; Jing, Xiao-Yuan; Zhang, Jing-Hua; Zhang, Jian-Xu

    2017-03-01

    Rats are predators of mice in nature. Nevertheless, it is a common practice to house mice and rats in a same room in some laboratories. In this study, we investigated the behavioral and physiological responsively of mice in long-term co-species housing conditions. Twenty-four male mice were randomly assigned to their original raising room (control) or a rat room (co-species-housed) for more than 6 weeks. In the open-field and light-dark box tests, the behaviors of the co-species-housed mice and controls were not different. In a 2-choice test of paired urine odors [rabbit urine (as a novel odor) vs. rat urine, cat urine (as a natural predator-scent) vs. rabbit urine, and cat urine vs. rat urine], the co-species-housed mice were more ready to investigate the rat urine odor compared with the controls and may have adapted to it. In an encounter test, the rat-room-exposed mice exhibited increased aggression levels, and their urines were more attractive to females. Correspondingly, the levels of major urinary proteins were increased in the co-species-housed mouse urine, along with some volatile pheromones. The serum testosterone levels were also enhanced in the co-species-housed mice, whereas the corticosterone levels were not different. The norepinephrine, dopamine, and 5-HT levels in the right hippocampus and striatum were not different between the 2. Our findings indicate that chronic co-species housing results in adaptation in male mice; furthermore, it appears that long-term rat-odor stimuli enhance the competitiveness of mice, which suggests that appropriate predator-odor stimuli may be important to the fitness of prey animals. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Comparison between Urine and Cervical Samples for HPV DNA Detection and Typing in Young Women in Colombia.

    PubMed

    Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina

    2016-09-01

    Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.

  19. Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients.

    PubMed

    Yu, Hoi-Ying Elsie; Agus, Michael; Kellogg, Mark D

    2011-11-01

    Diagnosis and management of diabetic ketoacidosis (DKA) often rely on the measurement of urine ketones along with blood glucose, anion gap, and pH. These values, however, do not reliably reflect the severity of ketoacidosis. The Abbott Precision Xceed Pro® meter is an FDA-approved device that quantitatively measures β-hydroxybutyrate (BOH) in whole blood. This study was undertaken to determine whether the ketone meter meets the analytical criteria to aid DKA diagnosis and management in the hospital. 54 heparinized venous whole blood BOH concentrations from 27 diabetic patients were measured by the Abbott meter, and compared with the plasma BOH concentrations measured with Stanbio reagent (reference method). Measurements were done in the hospital central laboratory. Of the 54 pairs of specimens analyzed, 17 pairs displayed a difference of >15% between the two methods. Nearly all discrepant points occurred when BOH >5 mmol/L (reference method). Linearity evaluation revealed that the meter is not linear from 0.0 to 8.0 mmol/L, contrary to the claim by the manufacturer. Further, we identified acetoacetate, a metabolite commonly present in DKA patients, as a potential interfering substance for the meter BOH measurement. BOH measurements by the Abbott meter up to 3 mmol/L correlate well with the reference method, but become discrepant above that point. While this characteristic may be useful in the diagnosis of DKA, it may not allow clinicians to serially follow the response to therapy in hospitalized DKA patients with BOH values greater than 5 mmol/L (reference method). © 2011 John Wiley & Sons A/S.

  20. NMR-based metabonomic study of the sub-acute toxicity of titanium dioxide nanoparticles in rats after oral administration

    NASA Astrophysics Data System (ADS)

    Bu, Qian; Yan, Guangyan; Deng, Pengchi; Peng, Feng; Lin, Hongjun; Xu, Youzhi; Cao, Zhixing; Zhou, Tian; Xue, Aiqin; Wang, Yanli; Cen, Xiaobo; Zhao, Ying-Lan

    2010-03-01

    As titanium dioxide nanoparticles (TiO2 NPs) are widely used commercially, their potential toxicity on human health has attracted particular attention. In the present study, the oral toxicological effects of TiO2 NPs (dosed at 0.16, 0.4 and 1 g kg - 1, respectively) were investigated using conventional approaches and metabonomic analysis in Wistar rats. Serum chemistry, hematology and histopathology examinations were performed. The urine and serum were investigated by 1H nuclear magnetic resonance (NMR) using principal components and partial least squares discriminant analysis. The metabolic signature of urinalysis in TiO2 NP-treated rats showed increases in the levels of taurine, citrate, hippurate, histidine, trimethylamine-N-oxide (TMAO), citrulline, α-ketoglutarate, phenylacetylglycine (PAG) and acetate; moreover, decreases in the levels of lactate, betaine, methionine, threonine, pyruvate, 3-D-hydroxybutyrate (3-D-HB), choline and leucine were observed. The metabonomics analysis of serum showed increases in TMAO, choline, creatine, phosphocholine and 3-D-HB as well as decreases in glutamine, pyruvate, glutamate, acetoacetate, glutathione and methionine after TiO2 NP treatment. Aspartate aminotransferase (AST), creatine kinase (CK) and lactate dehydrogenase (LDH) were elevated and mitochondrial swelling in heart tissue was observed in TiO2 NP-treated rats. These findings indicate that disturbances in energy and amino acid metabolism and the gut microflora environment may be attributable to the slight injury to the liver and heart caused by TiO2 NPs. Moreover, the NMR-based metabolomic approach is a reliable and sensitive method to study the biochemical effects of nanomaterials.

  1. Urine Protein and Urine Protein to Creatinine Ratio

    MedlinePlus

    ... Less Common Questions Related Content On This Site Tests: Urinalysis ; Albumin ; Urine Albumin ; Protein Electrophoresis ; Total Protein , BUN , Creatinine , Creatinine Clearance , eGFR Conditions: Kidney Disease , Proteinuria , Pre-eclampsia , Diabetes , Hypertension , Multiple Myeloma , Urinary Tract Infection ...

  2. Cytology exam of urine

    MedlinePlus

    Urine cytology; Bladder cancer - cytology; Urethral cancer - cytology; Renal cancer - cytology ... The test is done to detect cancer of the urinary tract. It is often done when blood is seen in the urine. It is also useful for monitoring people ...

  3. Extended testing of compression distillation.

    NASA Technical Reports Server (NTRS)

    Bambenek, R. A.; Nuccio, P. P.

    1972-01-01

    During the past eight years, the NASA Manned Spacecraft Center has supported the development of an integrated water and waste management system which includes the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water, and concentrated wash water. This paper describes the design of the compression distillation unit, developed for this system, and the testing performed to demonstrate its reliability and performance. In addition, this paper summarizes the work performed on pretreatment and post-treatment processes, to assure the recovery of sterile potable water from urine and treated urinal flush water.

  4. Conceptual Data Model for Administrative Functions of a Typical Naval Ship, to Include: Personnel, Training, Ship Secretary, Welfare and Recreation, Command Career Counselor, Public Affairs Officer, Educational Services Officer, Master at Arms, and Legal

    DTIC Science & Technology

    1991-09-01

    DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT REPAIR DEPARTMENT DEEP AIR WIN AIR REACTOR SUBMERGENCE PARIEMDT DEPDTMENT EPARTMENT (EMBARKED MAINTENANCECOMMAND...URIN DRUG L C,45 N URINALYS E SC: Name o druog 1E to which test was sent for testing URINALYSIS MEMBER BOTTLE INITIAL URIN MBR 9O L N URINALYS E SC...Indicates that meabiei initialed bottle that it was his urine URINALYSIS MEMBER SIGNATURE URIN MBR SI L N URINALYS E SC: Indicates that meber signed log

  5. [Delayed testing for the diagnosis of fungi in the urines. Evaluation of the BD Vacutainer C&S tubes for the storage of urine samples at room temperature].

    PubMed

    Baixench, M T; Al-Sheikh, M; Paugam, A

    2005-01-01

    The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.

  6. Evaluation of the bioNexia Legionella Test, Including Impact of Incubation Time Extension, for Detection of Legionella pneumophila Serogroup 1 Antigen in Urine.

    PubMed

    Badoux, Paul; Euser, Sjoerd M; Bruin, Jacob P; Mulder, Patrick P G; Yzerman, Ed P F

    2017-06-01

    In this study, we compared the bioNexia test (bioMérieux, Marcy-l'Étoile, France), a new immunochromatographic assay for the detection of Legionella pneumophila serogroup 1 in urine, with the BinaxNOW urinary antigen test (Alere, Waltham, Massachusetts, USA). After 15 min of incubation (in accordance with the manufacturers' instructions), the sensitivities and specificities were, respectively, 76.5% and 97.2% for the bioNexia test and 87.1% and 100% for the BinaxNOW test. After a prolonged incubation time of 60 min, the sensitivities and specificities increased to, respectively, 89.4% and 97.2% for the bioNexia test and 91.8% and 100% for the BinaxNOW test. When the tests were read after 15 min, the concentration of discrepant urine samples increased the sensitivities to 94.1% for both tests. In conclusion, we found that although the bioNexia test showed lower sensitivity for the detection of L. pneumophila antigen in nonconcentrated urine compared to the BinaxNOW test, a prolonged incubation time as well as the use of concentrated samples showed comparable sensitivities for both tests. Copyright © 2017 American Society for Microbiology.

  7. Military Nutrition Research: Four Tasks to Address Personnel Readiness and Warfighter Performance

    DTIC Science & Technology

    2007-03-01

    insulin, free fatty acids, beta hydroxybutyrate, glucagon, and IGF-1, epinephrine, norepinephrine, urine creatinine, urine total nitrogen, urine urea...project. • Completion of blood testing for Project 4. Specifically, the following tests were completed: AST, beta hydroxybutyrate, blood urea...Minehira, J-M Schwarz, K Acheson, P Schneiter, J Burri, E Jequier, and L Tappy. Mechanisms of action of ß- glucan in postprandial glucose metabolism

  8. Synthesis of novel heterocycles through reaction of indolin-2-one derivatives with active methylene and amino reagents.

    PubMed

    Abdel-Latif, F F; Ahmed, E K; Mekheimer, R; Mashaly, M M

    1997-10-01

    Several new spiro compounds were synthesized via one-pot ternary condensation of isatin, malononitrile and each of thiobarbituric acid, barbituric acid, 3-methyl-pyrazolin-5-one, 1-phenyl-3-methyl-pyrazolin-5-one, acetylacetone, benzoylacetone, ethyl acetoacetate, phenacyl cyanide or ethyl-cyanoacetate dimer. Structures and reaction mechanism were reported and supported via a second synthetic route.

  9. The further development of the active urine collection device: a novel continence management system.

    PubMed

    Tinnion, E; Jowitt, F; Clarke-O'Neill, S; Cottenden, A M; Fader, M; Sutherland, I

    2003-01-01

    Continence difficulties affect the lives of a substantial minority of the population. Women are far more likely than men to be affected by urinary incontinence but the range of management options for them is limited. There has been considerable interest in developing an external urine collection system for women but without success to date. This paper describes the development and preliminary clinical testing of an active urine collection device (AUCD), which could provide a solution for sufferers. The device uses stored vacuum, protected by a high bubble point filter, to remove urine as quickly as it is produced. This allows a small battery-operated pump to provide the required vacuum, enabling the device to be portable. Two different types of non-invasive patient/device interface were developed, and tested by volunteers: urinal and small pad. The slimline urinal was popular with users although liquid noise was a problem. The pad interface was successful on occasions but further work is necessary to produce a reliable pad. This study has successfully demonstrated that a prototype AUCD liquid handling system can remove urine at clinically relevant flowrates. While further development is required, volunteer tests have shown that the AUCD could be a useful advance in continence management.

  10. Rapid test by liquid chromatography/tandem mass spectrometry to evaluate equine urine reactivity towards 17beta-OH steroids.

    PubMed

    Fidani, Marco; Casagni, Eleonora; Montana, Marco; Pasello, Emanuela; Pecoraro, Chiara; Gambaro, Veniero

    2006-01-01

    Bacteria frequently found in equine urine samples may cause degradation of 17beta-OH steroids. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to evaluate the microbiological contamination of equine urine as a marker of poor storage conditions. Norethandrolone was used as the internal standard, and the linearity, sensitivity, precision and accuracy of the method were evaluated. 17beta-OH oxidation was demonstrated for testosterone, nandrolone, trenbolone and boldenone, but did not occur in alpha-epimers such as alpha-boldenone and epitestosterone, demonstrating the stereoselectivity of the reaction. A rapid test was performed by spiking one of the four 17beta-OH steroids in samples of diluted equine urine. The steroids were transformed into their respective ketones in the presence of bacterial activity. The test allows direct injection of diluted samples into the LC/MS system, without the need for prior extraction. Results show that the best method of storage is freezing at -18 degrees C. Urine specimens should be analyzed as soon as possible after thawing. This allows bacterial degradation of equine urine to be arrested temporarily, so that the urine can be used for qualitative or quantitative analysis of 17beta-OH steroids.

  11. 75 FR 75485 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-03

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Guidelines for Federal Workplace Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were... Laboratories and Instrumented Initial Testing Facilities (IITF) must meet in order to conduct drug and specimen...

  12. 75 FR 62842 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-13

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Guidelines for Federal Workplace Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were... and Instrumented Initial Testing Facilities (IITF) must meet in order to conduct drug and specimen...

  13. The value of a registry negative urine pregnancy test for the prediction of a future unintended pregnancy among young women.

    PubMed

    Rottenstreich, Misgav; Grisaru-Granovsky, Sorina; Rottenstreich, Amihai

    2018-06-01

    Performance of urine pregnancy test in general adolescents' clinic reflects caregiver or woman's concern that there might be a pregnancy. We aimed to assess whether young-unmarried women in whom a negative urine pregnancy test was registered would be at increased risk of a future unintended pregnancy. The study cohort included consecutive women drafted by the Israeli military between 2013 and 2015. The risk of unintended pregnancy was compared between women with a negative urine pregnancy test (n = 2774), the study group, and those in whom urine pregnancy test was not carried out (n = 126,659), the control group. During the study period, 2147 (1.7%) women experienced an unintended pregnancy. The risk of unintended pregnancy was significantly higher in patients in whom a past pregnancy test was negative 4.3% (n = 118), as compared with the control group 1.6% (n = 2028) (odds ratio [OR], 2.7; 95% confidence interval [CI], 2.23-3.26). In multivariate analysis history of a negative pregnancy test results was an independent predictor for a future unintended pregnancy (adjusted OR, 2.0; 95% CI, 1.63-2.52). A history of a negative pregnancy test among young conscripted women is a significant risk indicator for a future unintended pregnancy. Directed efforts should be made in this particular vulnerable group of patients.

  14. Stability studies of amphetamine and ephedrine derivatives in urine.

    PubMed

    Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R

    2006-10-20

    Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.

  15. Urine Tests (For Parents)

    MedlinePlus

    ... a doctor suspects that a child has a urinary tract infection (UTI) or a health problem that can cause an ... to-Creatinine Ratio Kidney Diseases in Childhood Recurrent Urinary Tract Infections and Related Conditions Urinary Tract Infections Urine Test: ...

  16. 49 CFR 40.67 - When and how is a directly observed collection conducted?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.67 When and how is a... employee urinate into the collection container. Specifically, you are to watch the urine go from the...

  17. 49 CFR 40.67 - When and how is a directly observed collection conducted?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.67 When and how is a... employee urinate into the collection container. Specifically, you are to watch the urine go from the...

  18. 49 CFR 40.67 - When and how is a directly observed collection conducted?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.67 When and how is a... employee urinate into the collection container. Specifically, you are to watch the urine go from the...

  19. Blood in the Urine (Hematuria)

    MedlinePlus

    ... 2 weeks later to make sure the urine is free of red blood cells. If hematuria only happens once, there's usually ... follow-up tests to make sure your urine is free of red blood cells. If the hematuria goes away, your doctor ...

  20. Urine testing for drugs of abuse: a survey of suburban parent-adolescent dyads.

    PubMed

    Schwartz, Richard H; Silber, Tomas J; Heyman, Richard B; Sheridan, Michael J; Estabrook, Dawn M

    2003-02-01

    The American Academy of Pediatrics is opposed to involuntary diagnostic testing for drugs of abuse. To gather data about attitudes of parents and their teenagers about involuntary drug testing on parental request. Adolescents and their accompanying parents separately answered a printed survey in the offices of their private pediatrician. The survey posed 2 hypothetical questions about urine testing: (1) Do parents have the right to ask a teenager's physician to order a urine test for drugs of abuse without the teenager's knowledge-if the teenager has falling school grades, an uncooperative attitude, and major untruthfulness? (2) In such a case, should the teenager's physician obtain a urine test for drugs on parental request only, without the teenager's consent? A total of 393 paired evaluable surveys were collected: 77.6% from Virginia and 22.4% from Ohio. There were no significant differences in answers between the 2 study sites. Of the students, 85.8% had either an A or a B grade point average. Current marijuana use was unusually low in our teenaged respondents. Of the parents surveyed, 81.7% would want a physician to be able to perform a urine test for drugs of abuse for a problematic teenager without the young person's consent. The answers to the 2 questions about urine drug tests had poor kappa coefficients of agreement between teenagers and parents (0.04 and 0.09, respectively). Reanalysis, using the variables of age, grade point average, and frequency of marijuana smoking, showed little difference in agreement scores. In the 2 suburban pediatric practices surveyed, parental opinions and expectations were at variance with the American Academy of Pediatrics policy statement on nonconsensual urine drug testing in the presence of clinical problems. Pediatricians need to be conscious of this clinical-ethical dilemma, become familiar with the American Academy of Pediatrics policy on drug testing, and develop their own position and expertise in this area. The dyad method (parent-teenager survey) is novel and improved the methodology of our study. We surveyed middle-class suburban adolescents while previous studies of adolescents surveyed inner-city populations.

  1. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  2. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  3. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  4. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  5. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  6. Temporary Urine and Brine Stowage System (TUBSS) Materials Selection and Testing

    NASA Technical Reports Server (NTRS)

    Carrigan, Caitlin; Dries, Kevin; Pensinger, Stuart

    2011-01-01

    Storing wastewater in the event of a system anomaly is a necessity for closed loop water recovery systems. The temporary urine and brine stowage system (TUBSS) is an assembly used to store and transfer pre-treated urine (PTU) and brine for processing or disposal at a later date. This paper describes the selection and testing of several candidate materials from both a chemical and material strength standpoint. In addition, this paper will provide results of testing as well as lessons learned from the project, culminating in the successful launch of the hardware.

  7. Comparison of Test Results for Zika Virus RNA in Urine, Serum, and Saliva Specimens from Persons with Travel-Associated Zika Virus Disease - Florida, 2016.

    PubMed

    Bingham, Andrea M; Cone, Marshall; Mock, Valerie; Heberlein-Larson, Lea; Stanek, Danielle; Blackmore, Carina; Likos, Anna

    2016-05-13

    In May 2015, Zika virus was reported to be circulating in Brazil. This was the first identified introduction of the virus in the Region of the Americas. Since that time, Zika virus has rapidly spread throughout the region. As of April 20, 2016, the Florida Department of Health Bureau of Public Health Laboratories (BPHL) has tested specimens from 913 persons who met state criteria for Zika virus testing. Among these 913 persons, 91 met confirmed or probable Zika virus disease case criteria and all cases were travel-associated (1). On the basis of previous small case studies reporting real time reverse-transcription polymerase chain reaction (RT-PCR) detection of Zika virus RNA in urine, saliva, and semen (2-6), the Florida Department of Health collected multiple specimen types from persons with suspected Zika virus disease. Test results were evaluated by specimen type and number of days after symptom onset to determine the most sensitive and efficient testing algorithm for acute Zika virus disease. Urine specimens were collected from 70 patients with suspected Zika virus disease from zero to 20 days after symptom onset. Of these, 65 (93%) tested positive for Zika virus RNA by RT-PCR. Results for 95% (52/55) of urine specimens collected from persons within 5 days of symptom onset tested positive by RT-PCR; only 56% (31/55) of serum specimens collected on the same date tested positive by RT-PCR. Results for 82% (9/11) of urine specimens collected >5 days after symptom onset tested positive by RT-PCR; none of the RT-PCR tests for serum specimens were positive. No cases had results that were exclusively positive by RT-PCR testing of saliva. BPHL testing results suggest urine might be the preferred specimen type to identify acute Zika virus disease.

  8. Comparison of Sofia Legionella FIA and BinaxNOW® Legionella urinary antigen card in two national reference centers.

    PubMed

    Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S

    2015-09-01

    The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.

  9. Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.

    PubMed

    Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M

    2017-09-01

    Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriguez, Branelle R.; Broyan, James Lee, Jr.

    2008-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  11. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Cibuzar, Branelle R.; Broyan, James Lee, Jr.

    2009-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  12. Mucus in Urine: MedlinePlus Lab Test Information

    MedlinePlus

    ... is normal. An excess amount may indicate a urinary tract infection (UTI) or other medical condition. A test called urinalysis ... your urinalysis if you have symptoms of a UTI. These include: Frequent urge to urinate, but little ...

  13. Evaluation of the performance of Human Papillomavirus testing in paired urine and clinician-collected cervical samples among women aged over 30 years in Bhutan.

    PubMed

    Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2017-04-08

    Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.

  14. An Initial Evaluation of a Comprehensive Continuing Care Intervention for Clients with Substance Use Disorders: My First Year of Recovery (MyFYR).

    PubMed

    McKay, James R; Knepper, Cheryl; Deneke, Erin; O'Reilly, Christopher; DuPont, Robert L

    2016-08-01

    Physician health programs (PHPs) generate high rates of sustained abstinence in addicted physicians, through a combination of formal treatment, self-help involvement, regular monitoring via random urine toxicology tests, and powerful incentives generated by the threat of losing one's medical license. Recently, Caron Treatment Centers developed a new continuing care intervention, "My First Year of Recovery" (MyFYR), which is modeled after PHPs but provides extended recovery support to a broader segment of those with substance use disorders. This paper presents initial outcome data from MyFYR. MyFYR features frequent outcomes monitoring via urine toxicology tests, and also includes a web-based social platform to coordinate efforts of recovery coaches, family members, and others (e.g., employers, probation officers). Participants were the first 198 clients who enrolled in MyFYR after participating in residential treatment at Caron. Substance use outcomes were determined by a combination of urine toxicology tests, client self-report, and information from family members obtained during a 12-month period following entry into MyFYR. Clients in MyFYR provided 70% of scheduled urine samples, for an average of 16.4 urine samples per client. Only 4.1% of the samples tested positive for alcohol or any drug. As determined by urine toxicology and client and family reports, 54% of the participants had some use of alcohol or drugs during the follow-up. Of these relapsed clients, 70.1% were retained or re-engaged in MyFYR, and of these, half were able to re-establish abstinence of two months duration or more, as documented by urine toxicology. These initial results are extremely promising, as they document high rates of sustained participation in urine drug test monitoring and positive outcome in clients not under the threat of losing a professional license or incarceration. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Reagent strip testing is not sensitive for the screening of asymptomatic bacteriuria in pregnant women.

    PubMed

    Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada

    2002-08-01

    The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.

  16. Evaluation of Aution Max AX-4030 and 9UB Uriflet, 10PA Aution Sticks urine dipsticks in the automated urine test strip analysis.

    PubMed

    Rota, Cristina; Biondi, Marco; Trenti, Tommaso

    2011-09-26

    Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and creatinine determination. The two instruments have demonstrated comparable performances: precision and correlation between instruments and strips, evaluated for chemical-physical parameters, were always good. Furthermore, accuracy was always very good: results of protein and glucose semi-quantitative measurements resulted to be highly correlated with those obtained by quantitative methods. Moreover, the semi-quantitative measurements of creatinine, employing Aution Sticks 10PA urine strips, were highly comparable with quantitative results. 10PA urine strips are eligible for urine creatinine determination with the possibility of correcting urinalysis results for urinary creatinine concentration, whenever necessary and calculating the protein creatinine ratio. Further studies should be carried out to evaluate effectiveness and appropriateness of the usage of creatinine semi-quantitative analysis.

  17. Unreliable alcohol testing in a shipping safety programme.

    PubMed

    Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn

    2009-08-10

    Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.

  18. Results of an Aboriginal community-based renal disease management program incorporating point of care testing for urine albumin:creatinine ratio.

    PubMed

    Shephard, M D S; Allen, G G; Paizis, K; Barbara, J A J; Batterham, M; Vanajek, A

    2006-01-01

    There has been a significant increase in the burden of renal disease among Aboriginal Australians over the past 15 years. Urine albumin:creatinine ratio (ACR) is a well-established marker of microalbuminuria and can be conveniently performed on the DCA 2000 point-of-care testing (POCT) analyser (Bayer Australia; Melbourne, VIC, Australia) with an on-site result available in 7 min. The application of the urine ACR POCT for renal disease risk assessment was pioneered by our group in the Umoona Kidney Project. This article describes the results of the management arm of the Umoona Kidney Project, which used point-of-care urine ACR testing for the first time within a management framework to monitor albuminuria in patients at highest risk of renal disease. The article also examines the analytical quality of POCT results and overall community acceptance of the Umoona Kidney Project. Adults clinically assessed by Flinders Medical Centre renal specialists as being at greatest risk for renal disease were offered the ACE inhibitor (ACEI) perindopril on a voluntary basis. Selected renal markers, including POCT urine ACR (conducted on-site by Umoona's Aboriginal health worker team), plasma electrolytes, urea, creatinine, calculated glomerular filtration rate and blood pressure were measured six monthly. Regular quality control testing was undertaken to monitor the analytical performance of the POCT analyser. A culturally appropriate questionnaire was designed and implemented to assess community satisfaction with the project. In all, 231 patient management consultations were conducted over a two year period, with over 70% of patients having four or more (up to a maximum of eight) consultations; 35 patients (mean age 49.2 [+/-2.3] years, 54% males) participated voluntarily in the management arm. All were overtly hypertensive, hypertensive with other risk factors or had diabetes. The renal status of these patients was followed for a mean of 63 +/- 4.5 weeks. In total, 111 POCT urine ACR tests were performed for patient management (mean 3.2 tests per patient). There was no significant difference in POCT urine ACR in the study period with a median (and inter-quartile range) of 5.7 mg/mmol (1.2-15.2) pre-ACEI and 4.3 mg/mmol (1.3-16.7) post-ACEI treatment (p = 0.50, Wilcoxon signed ranks test). The calculated glomerular filtration rate altered from 110 to 118 mL/min (p = 0.019, paired t-test). There was no change in the group plasma potassium, urea and creatinine. Collectively these results indicate a stabilisation in renal function among the management group. Blood pressure (both lying and standing) fell significantly in the study period. The imprecision for urine ACR quality control POCT conducted during the management program was within nationally and internationally accepted precision goals for urine albumin, creatinine and ACR. Fifty community members completed the satisfaction questionnaire. Three-quarters of respondents felt there were no cultural barriers in providing a urine sample for urine ACR POCT. The management arm of the Umoona Kidney Project was effective in stabilising the renal function and improving the blood pressure of community members identified to be at greatest risk of kidney disease. POCT urine ACR testing can be utilised, not only for community risk assessment, but also for patient management. The Umoona Kidney Project was well accepted by the health service and community members.

  19. The human gastric pathogen Helicobacter pylori has a potential acetone carboxylase that enhances its ability to colonize mice

    PubMed Central

    Brahmachary, Priyanka; Wang, Ge; Benoit, Stéphane L; Weinberg, Michael V; Maier, Robert J; Hoover, Timothy R

    2008-01-01

    Background Helicobacter pylori colonizes the human stomach and is the etiological agent of peptic ulcer disease. All three H. pylori strains that have been sequenced to date contain a potential operon whose products share homology with the subunits of acetone carboxylase (encoded by acxABC) from Xanthobacter autotrophicus strain Py2 and Rhodobacter capsulatus strain B10. Acetone carboxylase catalyzes the conversion of acetone to acetoacetate. Genes upstream of the putative acxABC operon encode enzymes that convert acetoacetate to acetoacetyl-CoA, which is metabolized further to generate two molecules of acetyl-CoA. Results To determine if the H. pylori acxABC operon has a role in host colonization the acxB homolog in the mouse-adapted H. pylori SS1 strain was inactivated with a chloramphenicol-resistance (cat) cassette. In mouse colonization studies the numbers of H. pylori recovered from mice inoculated with the acxB:cat mutant were generally one to two orders of magnitude lower than those recovered from mice inoculated with the parental strain. A statistical analysis of the data using a Wilcoxin Rank test indicated the differences in the numbers of H. pylori isolated from mice inoculated with the two strains were significant at the 99% confidence level. Levels of acetone associated with gastric tissue removed from uninfected mice were measured and found to range from 10–110 μmols per gram wet weight tissue. Conclusion The colonization defect of the acxB:cat mutant suggests a role for the acxABC operon in survival of the bacterium in the stomach. Products of the H. pylori acxABC operon may function primarily in acetone utilization or may catalyze a related reaction that is important for survival or growth in the host. H. pylori encounters significant levels of acetone in the stomach which it could use as a potential electron donor for microaerobic respiration. PMID:18215283

  20. Urine Toxicology in Adults Evaluated for a Central Hypersomnia and How the Results Modify the Physician's Diagnosis.

    PubMed

    Kosky, Christopher A; Bonakis, Anastasios; Yogendran, Arthee; Hettiarachchi, Gihan; Dargan, Paul I; Williams, Adrian J

    2016-11-15

    Drugs and psychoactive substances can cause sleepiness and when undetected, may lead to over diagnosis of central hypersomnias. We performed urine drug testing using gas chromatography-mass spectrometry in adults undergoing multiple sleep latency testing (MSLT) for a suspected central hypersomnia. We examined how the drug test results modified the treating physician's diagnosis. One hundred eighty-six consecutive patients with a suspected central hypersomnia who underwent clinical assessment, MSLT and urine drug testing by gas chromatography-mass spectrometry were retrospectively studied. Physicians made a diagnosis after clinical assessment and MSLT and were initially blinded to the urine drug test results. A third of patients assessed for subjective hypersomnia had a positive urine drug test for a substance affecting sleep. Opioids, cannabis, and amphetamines were the commonest drugs detected. Using MSLT, 35 (18.8%) of 186 patients had objective hypersomnia that may have been due to a drug or substance. Drugs or substances may have confounded the MSLT in 11 (20.1%) of 53 patients who fulfilled diagnostic criteria for idiopathic hypersomnia, and 12 (52%) of 23 of those who fulfilled diagnostic criteria for narcolepsy without cataplexy. Of the 75 positive urine drug samples, 61 (81%) were substances or medications not revealed in the physician interview. The treating physician had not suspected drugs or substances as a possible cause of objective hypersomnia in 34 (97%) of the 35 patients. Drugs and psychoactive substances can confound the results of the MSLT and when undetected could lead to over diagnosis of central hypersomnias. © 2016 American Academy of Sleep Medicine

  1. Direct Detection and Genotyping of Klebsiella pneumoniae Carbapenemases from Urine by Use of a New DNA Microarray Test

    PubMed Central

    Peter, Harald; Berggrav, Kathrine; Thomas, Peter; Pfeifer, Yvonne; Witte, Wolfgang; Templeton, Kate

    2012-01-01

    Klebsiella pneumoniae carbapenemases (KPCs) are considered a serious threat to antibiotic therapy, as they confer resistance to carbapenems, which are used to treat extended-spectrum beta-lactamase (ESBL)-producing bacteria. Here, we describe the development and evaluation of a DNA microarray for the detection and genotyping of KPC genes (blaKPC) within a 5-h period. To test the whole assay procedure (DNA extraction plus a DNA microarray assay) directly from clinical specimens, we compared two commercial DNA extraction kits (the QIAprep Spin miniprep kit [Qiagen] and the urine bacterial DNA isolation kit [Norgen]) for the direct DNA extraction from urine samples (dilution series spiked in human urine). Reliable single nucleotide polymorphism (SNP) typing was demonstrated using 1 × 105 CFU/ml urine for Escherichia coli (Qiagen and Norgen) and 80 CFU/ml urine, on average, for K. pneumoniae (Norgen). This study presents, for the first time, the combination of a new KPC microarray with commercial sample preparation for detecting and genotyping microbial pathogens directly from clinical specimens; this paves the way toward tests providing epidemiological and diagnostic data, enabling better antimicrobial stewardship. PMID:23035190

  2. A trend analysis of laboratory positive propoxyphene workplace urine drug screens before and after the product recall.

    PubMed

    Price, James

    2015-01-01

    Propoxyphene was withdrawn from the US market in November 2010. This drug is still tested for in the workplace as part of expanded panel nonregulated testing. A convenience sample of urine specimens (n = 7838) were provided by workers from various industries. The percentage of positive specimens with 95% confidence intervals was calculated for each year of the study. Logistic regression was used to assess the impact of the year upon the propoxyphene result. The prevalence of positive propoxyphene tests was much higher before the product's withdrawal from the market. Logistic regression provided evidence of a decreasing linear trend (P < 0.000; β = -0.71). The odds ratio signifies that for every additional year the urine specimens were 0.49 times less likely to be positive for propoxyphene. This favors the determination that the change in propoxyphene positive drug test over the years is not by chance. The conclusion supports no longer performing nonregulated workplace propoxyphene urine drug testing for this population.

  3. Impaired insight in cocaine addiction: laboratory evidence and effects on cocaine-seeking behaviour

    PubMed Central

    Maloney, Thomas; Parvaz, Muhammad A.; Alia-Klein, Nelly; Woicik, Patricia A.; Telang, Frank; Wang, Gene-Jack; Volkow, Nora D.; Goldstein, Rita Z.

    2010-01-01

    Neuropsychiatric disorders are often characterized by impaired insight into behaviour. Such an insight deficit has been suggested, but never directly tested, in drug addiction. Here we tested for the first time this impaired insight hypothesis in drug addiction, and examined its potential association with drug-seeking behaviour. We also tested potential modulation of these effects by cocaine urine status, an individual difference known to impact underlying cognitive functions and prognosis. Sixteen cocaine addicted individuals testing positive for cocaine in urine, 26 cocaine addicted individuals testing negative for cocaine in urine, and 23 healthy controls completed a probabilistic choice task that assessed objective preference for viewing four types of pictures (pleasant, unpleasant, neutral and cocaine). This choice task concluded by asking subjects to report their most selected picture type; correspondence between subjects’ self-reports with their objective choice behaviour provided our index of behavioural insight. Results showed that the urine positive cocaine subjects exhibited impaired insight into their own choice behaviour compared with healthy controls; this same study group also selected the most cocaine pictures (and fewest pleasant pictures) for viewing. Importantly, however, it was the urine negative cocaine subjects whose behaviour was most influenced by insight, such that impaired insight in this subgroup only was associated with higher cocaine-related choice on the task and more severe actual cocaine use. These findings suggest that interventions to enhance insight may decrease drug-seeking behaviour, especially in urine negative cocaine subjects, potentially to improve their longer-term clinical outcomes. PMID:20395264

  4. Direct urine polymerase chain reaction for chlamydia and gonorrhoea: a simple means of bringing high-throughput rapid testing to remote settings?

    PubMed

    Rahimi, Frashta; Goire, Namraj; Guy, Rebecca; Kaldor, John M; Ward, James; Nissen, Michael D; Sloots, Theo P; Whiley, David M

    2013-08-01

    Background Rapid point-of-care tests (POCTs) for chlamydia (Chlamydia trachomatis) and gonorrhoea (Neisseria gonorrhoeae) have the potential to confer health benefits in certain populations even at moderate sensitivities; however, suitable POCTs for these organisms are currently lacking. In this study, we investigated the use of direct urine polymerase chain reaction (PCR), with the view of implementing a simplified PCR strategy for high-throughput chlamydia and gonorrhoea screening in remote settings. Briefly, a simple dilution of the urine was performed before adding it directly to a real-time PCR reaction. The method was evaluated using 134 stored urine specimens that had been submitted for chlamydia and gonorrhoea testing and had been tested using a commercial C. trachomatis and N. gonorrhoeae PCR method. These included samples that were PCR-positive for chlamydia (n=87), gonorrhoea (n=16) or both (n=2). Direct urine testing was conducted using previously described in-house real-time PCR methods for C. trachomatis and N. gonorrhoeae as well as for recognised N.gonorrhoeae antimicrobial resistance mechanisms. The overall sensitivities and specificities of the direct urine PCR were 78% and 100% for chlamydia, and 83% and 100% for gonorrhoea. N.gonorrhoeae penicillin and quinolone resistance mechanisms were characterised in 14 of the 18 N. gonorrhoeae-positive samples. The results of this study show that the simplified PCR strategy may be a feasible approach for rapid screening and improving chlamydia and gonorrhoea treatment in remote settings.

  5. The uriscreen test to detect significant asymptomatic bacteriuria during pregnancy.

    PubMed

    Teppa, Roberto J; Roberts, James M

    2005-01-01

    Asymptomatic bacteriuria (ASB) occurs in 2-11% of pregnancies and it is a clear predisposition to the development of acute pyelonephritis, which, in turn, poses risk to mother and fetus. Treatment of bacteriuria during pregnancy reduces the incidence of pyelonephritis. Therefore, it is recommended to screen for ASB at the first prenatal visit. The gold standard for detection of bacteriuria during pregnancy is urine culture, but this test is expensive, time-consuming, and labor-intensive. To determine the reliability of an enzymatic urine screening test (Uriscreen; Savyon Diagnostics, Ashdod, Israel) for detecting ASB in pregnancy. Catheterized urine samples were collected from 150 women who had routine prenatal screening for ASB. Patients with urinary symptoms, active vaginal bleeding, or who were previously on antibiotics therapy were excluded from the study. Sensitivity, specificity, and the positive and negative predictive values for the Uriscreen were estimated using urine culture as the criterion standard. Urine cultures were considered positive if they grew >10(5) colony-forming units of a single uropathogen. Twenty-eight women (18.7%) had urine culture results indicating significant bacteriuria, and 17 of these 28 specimens had positive enzyme activity. Of 122 samples with no growth, 109 had negative enzyme activity. Sensitivity, specificity, and positive and negative predictive values for the Uriscreen test were 60.7% (+/-18.1), 89.3% (+/-5.6), 56.6%, and 90.8%, respectively. The Uriscreen test had inadequate sensitivity for rapid screening of bacteriuria in pregnancy.

  6. Blood in the Urine (Hematuria) (For Parents)

    MedlinePlus

    ... weeks later, just to make sure the urine is free of red blood cells. Hematuria that only happens once won't ... up tests to make sure your child's urine is free of red blood cells. Reviewed by: Robert S. Mathias, MD Date reviewed: ...

  7. Urine culture guided antibiotic interventions: A pharmacist driven antimicrobial stewardship effort in the ED.

    PubMed

    Zhang, Xi; Rowan, Nicole; Pflugeisen, Bethann Mangel; Alajbegovic, Sanjin

    2017-04-01

    Antibiotics are overprescribed for abnormal urine tests including asymptomatic bacteriuria (AB), contributing to rising antimicrobial resistance rates. Pharmacists reviewed urine cultures daily from emergency department (ED) encounters to assess antibiotic appropriateness. We studied antibiotic prescribing practices and assessed compliance to national guidelines, correlations with urine analysis (UA) components, and opportunities for antimicrobial stewardship in the ED. This quality improvement project (QIP) was a prospective cohort study at a community hospital ED, with data collected from finalized urine cultures resulting October 30, 2014 through January 5, 2015. Analyses were conducted using Chi-squared and Fisher Exact tests and stepwise multiple logistic regression. Urine cultures from 457 encounters were reviewed, of which 136 met the inclusion criteria as non-pregnant and asymptomatic for urinary tract infection (UTI). 43% of 136 patients were treated with antibiotics, for a total of 426 antibiotic days. Pharmacist interventions for these patients resulted in 122/426 (29%) of potential antibiotic days saved. Factors found to significantly increase the odds of antibiotic prescribing in asymptomatic patients included presence of leukocyte esterase (OR=4.5, 95% CI: 1.2-17.2; p=0.03) or nitrites (OR=10.8, 95% CI: 1.7-68.1; p=0.01) in the urine and age≥75 (OR=3.5, 95% CI: 1.2-9.6, p=0.02). Pharmacist intervention in discontinuing or modifying antibiotics for asymptomatic patients with urine cultures reduced unnecessary antibiotic exposure and was a first step in antimicrobial stewardship efforts in the ED. Future work includes limiting urine tests and subsequent antibiotic therapy for non-pregnant asymptomatic patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. NMR-based metabonomics study on the effect of Gancao in the attenuation of toxicity in rats induced by Fuzi.

    PubMed

    Sun, Bo; Wang, Xubin; Cao, Ruili; Zhang, Qi; Liu, Qiao; Xu, Meifeng; Zhang, Ming; Du, Xiangbo; Dong, Fangting; Yan, Xianzhong

    2016-12-04

    Fuzi, the processed lateral root of Aconitum carmichaelii Debeaux, is a traditional Chinese medicine used for its analgesic, antipyretic, anti-rheumatoid arthritis and anti-inflammation effects; however, it is also well known for its toxicity. Gancao, the root of Glycyrrhiza uralensis Fisch., is often used concurrently with Fuzi to alleviate its toxicity. However, the mechanism of detoxication is still not well clear. In this study, the effect of Gancao on the metabolic changes induced by Fuzi was investigated by NMR-based metabonomic approaches. Fifty male Wistar rats were randomly divided into five groups (group A: control, group B: Fuzi decoction alone, group C: Gancao decoction alone, group D: Fuzi decoction and Gancao decoction simultaneously, group E: Fuzi decoction 5h after Gancao decoction) and urine samples were collected for NMR-based metabolic profiling analysis. Statistical analyses such as unsupervised PCA, t-test, hierarchical cluster, and pathway analysis were used to detect the effects of Gancao on the metabolic changes induced by Fuzi. The behavioral and biochemical characteristics showed that Fuzi exhibited toxic effects on treated rats (group B) and statistical analyses showed that their metabolic profiles were in contrast to those in groups A and C. However, when Fuzi was administered with Gancao, the metabolic profiles became similar to controls, whereby Gancao reduced the levels of trimethylamine N-oxide, betaine, dimethylglycine, valine, acetoacetate, citrate, fumarate, 2-ketoglutarate and hippurate, and regulated the concentrations of taurine and 3-hydroxybutyrate, resulting in a decrease in toxicity. Furthermore, important pathways that are known to be involved in the effect of Gancao on Fuzi, including phenylalanine, tyrosine and tryptophan biosynthesis, the synthesis and degradation of ketone bodies, and the TCA cycle, were altered in co-treated rats. Gancao treatment mitigated the metabolic changes altered by Fuzi administration in rats, demonstrating that dosing with Gancao could reduce the toxicity of Fuzi at the metabolic level. Fuzi and Gancao administered simultaneously resulted in improved toxicity reduction than when Gancao was administrated 5h prior to Fuzi. In summary, co-administration of Gancao with Fuzi reduces toxicity at the metabolic level. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Water recovery by catalytic treatment of urine vapor

    NASA Technical Reports Server (NTRS)

    Budininkas, P.; Quattrone, P. D.; Leban, M. I.

    1980-01-01

    The objective of this investigation was to demonstrate the feasibility of water recovery on a man-rated scale by the catalytic processing of untreated urine vapor. For this purpose, two catalytic systems, one capable of processing an air stream containing low urine vapor concentrations and another to process streams with high urine vapor concentrations, were designed, constructed, and tested to establish the quality of the recovered water.

  10. Urine human papillomavirus prevalence in women with high-grade cervical lesions.

    PubMed

    Nicolau, P; Mancebo, G; Agramunt, S; Solé-Sedeño, J M; Bellosillo, B; Muset, M M; Lloveras, B; Alameda, F; Carreras, R

    2014-12-01

    To determine the prevalence of human papillomavirus (HPV) in urine samples from women with high-grade cervical lesions. Secondary objectives are to identify the influence of socio-demographic factors and the different genotypes with urinary HPV positivity. 75 women with a positive biopsy for CIN2+ were included in the study from October 2010 to July 2011. A sample of urine was collected immediately before conization at the outpatient clinic. We analyzed the presence of HPV using a PCR technique. The mean age of the patients was 34.8 years (range 24 to 61). All patients had histological CIN2+, of whom 54.67% had CIN3. The prevalence of HPV in urine test was 58.82% in CIN2 population versus 78.05% in CIN3 patients (p 0.072). 31 different genotypes were found. The most frequent HPV genotype was 16-HPV, which was identified in 58% of women with positive HPV-DNA in urine samples. No demographic characteristics were significantly associated to urinary HPV prevalence. Most of the patients with CIN2+ showed positive results for urine HPV test. The prevalence of positive urinary HPV test was higher for patients with CIN3. HPV urine detection could be considered as an acceptable option for high-risk population who skip regular screening programs. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Factitious diarrhea induced by stimulant laxatives: accuracy of diagnosis by a clinical reference laboratory using thin layer chromatography.

    PubMed

    Shelton, Joseph H; Santa Ana, Carol A; Thompson, Donald R; Emmett, Michael; Fordtran, John S

    2007-01-01

    Surreptitious ingestion of laxatives can lead to serious factitious diseases that are difficult to diagnose. Most cases involve ingestion of bisacodyl or senna. Thin layer chromatography (TLC) of urine or stool is the only commercially available test for these laxatives. Such testing is considered highly reliable, but its accuracy in clinical practice is unknown. Our aim was to evaluate the reliability of TLC laxative testing by a clinical reference laboratory in the United States. Diarrhea was induced in healthy volunteers by ingestion of bisacodyl, senna, or a control laxative (n = 11 for each laxative group). Samples of urine and diarrheal stool were sent in blinded fashion to the clinical reference laboratory for bisacodyl and senna analysis. TLC testing for bisacodyl-induced diarrhea revealed a sensitivity of 73% and specificity of 91% when urine was tested and sensitivity and specificity of 91% and 96%, respectively, when stool was analyzed. When diarrhea was induced by senna, the TLC assay for senna failed to identify even a single urine or stool specimen as positive (zero% sensitivity). Considering the expected prevalence of surreptitious laxative abuse in patients with chronic idiopathic diarrhea (2.4%-25%, depending on the clinical setting), TLC of urine or stool for bisacodyl by this reference laboratory would often produce misleading results, and testing for senna would have no clinical value. The major problems are false-positive tests for bisacodyl and false-negative tests for senna.

  12. Utility of ELISA screening for the monitoring of abstinence from illegal and legal drugs in hair and urine.

    PubMed

    Agius, Ronald; Nadulski, Thomas

    2014-06-01

    Amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in authentic hair samples with drug concentrations around the medical and psychological assessment (MPA) guidelines cut-offs were screened by LUCIO-direct ELISA kits. Following confirmation of all positive and a significant number of negatively screened samples with gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods accredited for forensic purposes. Receiver operating characteristics (ROC) were plotted and the area under the curve (AUC) and overall misclassification rate (OMR) were calculated and compared to those obtained for the same drug classes in urine. While fulfilling the validation criteria of the German forensic guidelines, for almost all screening tests in hair and urine the AUC were greater than 0.8, indicating good to excellent performance. Moreover the AUC calculated for the detection of drugs in hair did not differ significantly to the AUC calculated for the detection of the same drug classes in urine, thus showing a comparable screening performance to the well accepted, previously published application of the same ELISAs for the detection of drugs at unconventionally low cut-offs in urine. For the first time, the validation of the immunoassay tests for the complete 6-drug panel MPA profile in hair and urine using a large population of authentic hair and urine samples with drug concentrations around MPA cut-offs, lower than conventional clinical or workplace drug testing guidelines cut-offs as well as those suggested by the Society of hair testing (SoHT) is presented. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Evaluation of the BinaxNOW® Streptococcus pneumoniae antigen test on fresh, frozen and concentrated urine samples in elderly patients with and without community-acquired pneumonia.

    PubMed

    Saukkoriipi, Annika; Pascal, Thierry; Palmu, Arto A

    2016-02-01

    We evaluated the BinaxNOW® urine antigen test in elderly. For fresh un-concentrated urine samples, the sensitivity for pneumococcal pneumonia was 63% and specificity 97%. After freezing and concentration, the results comparable to positive control line in intensity at 60 min gave high sensitivity (81%) with no loss in specificity (96%). Copyright © 2015 Elsevier B.V. All rights reserved.

  14. CuI/L-proline-catalyzed coupling reactions of aryl halides with activated methylene compounds.

    PubMed

    Xie, Xiaoan; Cai, Guorong; Ma, Dawei

    2005-10-13

    [reaction: see text] The arylation of ethyl acetoacetate, ethyl benzoyl acetate, and diethyl malonate under the catalysis of CuI/L-proline in DMSO proceeds smoothly at 40-50 degrees C in the presence of Cs2CO3 to provide the 2-aryl-1,3-dicarbonyl compounds in good yields. Both aryl iodides and aryl bromides are compatible with these reaction conditions.

  15. Ketone bodies and brain glutamate and GABA metabolism.

    PubMed

    Daikhin, Y; Yudkoff, M

    1998-01-01

    The effects of ketone bodies on brain metabolism of glutamate and GABA were studied in three different systems: synaptosomes, cultured astrocytes and the whole animal. In synaptosomes the addition of either acetoacetate or 3-OH-butyrate was associated with diminished consumption of glutamate via transamination to aspartate and increased formation of labelled GABA from either L-[2H5-2,3,3,4, 4]glutamine or L-[15N]glutamine. There was no effect of ketone bodies on synaptosomal GABA transamination. An increase of total forebrain GABA and a diminution of aspartate was noted when mice were injected intraperitoneally with 3-OH-butyrate. In cultured astrocytes the addition of acetoacetate to the medium was associated with a significantly enhanced rate of citrate production and with a diminution in the rate of conversion of [15N]glutamate to [15N]aspartate. These data are consistent with the hypothesis that the metabolism of ketone bodies to acetyl-CoA results in a diminution of the pool of brain oxaloacetate, which is consumed in the citrate synthetase reaction (oxaloacetate + acetyl-CoA --> citrate). As less oxaloacetate is available to the aspartate aminotransferase reaction, thereby lowering the rate of glutamate transamination, more glutamate becomes accessible to the glutamate decarboxylase pathway, thereby favoring the synthesis of GABA.

  16. Diagnostic accuracy, incremental yield and prognostic value of Determine TB-LAM for routine diagnostic testing for tuberculosis in HIV-infected patients requiring acute hospital admission in South Africa: a prospective cohort.

    PubMed

    Lawn, Stephen D; Kerkhoff, Andrew D; Burton, Rosie; Schutz, Charlotte; Boulle, Andrew; Vogt, Monica; Gupta-Wright, Ankur; Nicol, Mark P; Meintjes, Graeme

    2017-03-21

    We previously reported that one-third of HIV-positive adults requiring medical admission to a South African district hospital had laboratory-confirmed tuberculosis (TB) and that almost two-thirds of cases could be rapidly diagnosed using Xpert MTB/RIF-testing of concentrated urine samples obtained on the first day of admission. Implementation of urine-based, routine, point-of-care TB screening is an attractive intervention that might be facilitated by use of a simple, low-cost diagnostic tool, such as the Determine TB-LAM lateral-flow rapid test for HIV-associated TB. Sputum, urine and blood samples were systematically obtained from unselected HIV-positive adults within 24 hours of admission to a South African township hospital. Additional clinical samples were obtained during hospitalization as clinically indicated. TB was defined by the detection of Mycobacterium tuberculosis in any sample using Xpert MTB/RIF or liquid culture. The diagnostic yield, accuracy and prognostic value of urine-lipoarabinomannan (LAM) testing were determined, but urine-LAM results did not inform treatment decisions. Consecutive HIV-positive adult acute medical admissions not already receiving TB treatment (n = 427) were enrolled regardless of clinical presentation or symptoms. TB was diagnosed in 139 patients (TB prevalence 32.6%; median CD4 count 80 cells/μL). In the first 24 hours of admission, sputum (spot and/or induced) samples were obtained from 37.0% of patients and urine samples from 99.5% of patients (P < 0.001). The diagnostic yields from these specimens were 19.4% (n = 27/139) for sputum-microscopy, 26.6% (n = 37/139) for sputum-Xpert, 38.1% (n = 53/139) for urine-LAM and 52.5% (n = 73/139) for sputum-Xpert/urine-LAM combined (P < 0.01). Corresponding yields among patients with CD4 counts <100 cells/μL were 18.9%, 24.3%, 55.4% and 63.5%, respectively (P < 0.01). The diagnostic yield of urine-LAM was unrelated to respiratory symptoms, and LAM assay specificity (using a grade-2 cut-off) was 98.9% (274/277; 95% confidence interval [CI] 96.9-99.8). Among TB cases, positive urine-LAM status was strongly associated with mortality at 90 days (adjusted hazard ratio 4.20; 95% CI 1.50-11.75). Routine testing for TB in newly admitted HIV-positive adults using Determine TB-LAM to test urine provides major incremental diagnostic yield with very high specificity when used in combination with sputum testing and has important utility among those without respiratory TB symptoms and/or unable to produce sputum. The assay also rapidly identifies individuals with a poor prognosis.

  17. Assessment of Early Postpartum Reproductive Performance in Two High Producing Estonian Dairy Herds

    PubMed Central

    Kask, K; Kurykin, J; Lindjärv, R; Kask, A; Kindahl, H

    2003-01-01

    Early postpartum (6 weeks) ovarian activity, hormonal profiles, uterine involution, uterine infections, serum electrolytes, glucose, milk acetoacetate and blood urea nitrogen (BUN) levels were studied in 2 Estonian high producing dairy herd with annual milk production of 7688 (Farm A) and 9425 (Farm B). From each farm 10 cows, with normal calving performance were used. Blood samples for the hormonal (PGF2α-metabolite, progesterone) analyses were withdrawn. On day 25 PP blood serum samples were taken for the evaluation of metabolic/electrolyte status. On the same day estimation of milk acetoacetate values was done. The ultrasound (US) was started on day 7 PP and was performed every 3rd day until the end of experiment. Uterine content, follicular activity and sizes of the largest follicle and corpus luteum were monitored and measured. Vaginal discharge and uterine tone were recorded during the rectal palpation. Each animal in the study was sampled for bacteriological examination using endometrial biopsies once a week. Two types of PGF2α-metabolite patterns were detected: elevated levels during 14 days PP, then decline to the basal level and then a second small elevation at the time of final elimination of the bacteria from the uterus; or elevated levels during first 7 days PP, then decline to the basal level and a second small elevation before the final elimination of bacteria. Endometritis was diagnosed in 5 cows in farm A and in 3 cows in farm B respectively. In farm A, 5 cows out of 10 ovulated during experimental period and in 1 cow cystic ovaries were found. In farm B, 3 cows out of 10 ovulated. In 3 cows cystic ovaries were found. Altogether 40% of cows had their first ovulation during the experimental period. Three cows in farm A and 5 cows in farm B were totally bacteria negative during the experimental period. The most frequent bacteria found were A. pyogenes, Streptococcus spp., E. coli., F. necrophorum and Bacteroides spp. The highest incidence of bacteriological species was found during the first 3 weeks in both farms. All animals were free from bacteria after 5th week PP in farm A and after 4th week in farm B respectively. Serum electrolytes and glucose levels were found to be within the reference limits for the cows in both farms. No significant difference was found between farms (p > 0.05). Low phosphorus levels were found in both farms. Significant difference (p < 0.05) was found in BUN levels between farms. In both farms milk acetoacetate values were staying within the reference range given for the used test (<100 μmol/l). The uterine involution and bacterial elimination in the investigated cows could consider as normal but more profound metabolic studies could be needed to find reasons for later resumption of ovarian activity. Some recommendations to changing feeding regimes and strategies should also be given. PMID:15074626

  18. 21 CFR 862.1550 - Urinary pH (nonquantitative) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (nonquantitative) test system is a device intended to estimate the pH of urine. Estimations of pH are used to evaluate the acidity or alkalinity of urine as it relates to numerous renal and metabolic disorders and in...

  19. 21 CFR 862.1550 - Urinary pH (nonquantitative) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (nonquantitative) test system is a device intended to estimate the pH of urine. Estimations of pH are used to evaluate the acidity or alkalinity of urine as it relates to numerous renal and metabolic disorders and in...

  20. 49 CFR 40.45 - What form is used to document a DOT urine collection?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Collection Sites, Forms, Equipment and Supplies Used... Federal Drug Testing Custody and Control Form (CCF) must be used to document every urine collection required by the DOT drug testing program. The CCF must be a five-part carbonless manifold form. You may...

  1. 49 CFR 40.45 - What form is used to document a DOT urine collection?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Collection Sites, Forms, Equipment and Supplies Used... Federal Drug Testing Custody and Control Form (CCF) must be used to document every urine collection required by the DOT drug testing program. The CCF must be a five-part carbonless manifold form. You may...

  2. 49 CFR 40.45 - What form is used to document a DOT urine collection?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Collection Sites, Forms, Equipment and Supplies Used... Federal Drug Testing Custody and Control Form (CCF) must be used to document every urine collection required by the DOT drug testing program. The CCF must be a five-part carbonless manifold form. You may...

  3. Development of a nanogold-based immunochromatographic assay for detection of morphine in urine using the Amor-HK16 monoclonal antibody.

    PubMed

    Dehghannezhad, Ardeshir; Paknejad, Maliheh; Rasaee, Mohammad Javad; Omidfar, Kobra; Seyyed Ebrahimi, Shadi Sadat; Ghahremani, Hossein

    2012-12-01

    A simple, rapid competitive immunochromatography (ICG) strip test was developed to detect morphine in urine samples using a monoclonal antibody produced in-house and conjugated to gold nanoparticles. Hybridoma cells were cultured and the Amor-HK16 monoclonal antibody against morphine was obtained from the supernatant after purification by salting out and passing through a Protein G-Agarose affinity column. Morphine was obtained from morphine sulfate and a C6-hemisuccinate derivative of morphine was prepared, conjugated to bovine serum albumin, and immobilized to a nitrocellulose membrane as the test line. Goat anti-mouse antibody was used as a binder in the control line in the detection zone of the strip. Colloidal gold particles of diameter approximately 20 nm were prepared and conjugated to the monoclonal antibody. The detection limit of the test strip was found to be 2000 ng/mL of morphine in urine samples. Reliability was determined by performing the ICG test on 103 urine samples and comparing the results with those obtained by thin-layer chromatography. The sensitivity of the test was 100%, and the analysis time for the assay was approximately 5 min. The new ICG method was adequately sensitive and accurate for the rapid screening of morphine in urine.

  4. Performance of the dipstick screening test as a predictor of negative urine culture.

    PubMed

    Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio Dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle

    2017-01-01

    To investigate whether the urine dipstick screening test can be used to predict urine culture results. A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. Verificar se a triagem de urina por fitas reativas é capaz de predizer a cultura de urina. Métodos Estudo retrospectivo realizado entre janeiro e dezembro de 2014 com 8.587 pacientes, com solicitação médica de triagem de urina (fita), sedimento urinário e cultura de urina. sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e curva ROC. Foram positivas 17,5% das culturas. O nitrito apresentou sensibilidade de 28% e especificidade de 99%. O valor preditivo positivo foi de 89% e o valor preditivo negativo de 87%. Esterase apresentou sensibilidade de 79% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram de 51% e 95%, respectivamente. A combinação de nitrito ou esterase positivos apresentou sensibilidade de 85% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram, respectivamente, 53% e 96%. O sedimento positivo (mais de dez leucócitos por microlitro) apresentou sensibilidade de 92% e especificidade de 71%. O valor preditivo positivo foi 40% e o negativo, 98%. A combinação de nitrito e sedimento urinário positivos apresentou sensibilidade de 82% e especificidade de 99%. Os valores preditivos positivo e negativo foram 91% e 98%, respectivamente. Para o nitrito ou esterase positivos mais os leucócitos positivos, a sensibilidade foi de 94% e a especificidade de 84%. O valor preditivo positivo foi de 58% e o negativo foi de 99%. Com base na curva ROC, o melhor indicador de urocultura positiva foi a associação entre a esterase ou nitrito positivos na fita mais os leucócitos positivos no sedimento, seguido por nitrito e esterase positivos, sedimento urinário positivo isolado, esterase positiva isolada, nitrito positivo isolado e, finalmente, pela associação entre nitrito e sedimento urinário positivos (AUC: 0,845, 0,844, 0,817, 0,814, 0,635 e 0,626, respectivamente). Uma urocultura negativa pode ser prevista com resultados negativos na fita. Portanto, este teste pode ser um preditor confiável de urocultura negativa.

  5. Urine Toxicology in Adults Evaluated for a Central Hypersomnia and How the Results Modify the Physician's Diagnosis

    PubMed Central

    Kosky, Christopher A.; Bonakis, Anastasios; Yogendran, Arthee; Hettiarachchi, Gihan; Dargan, Paul I.; Williams, Adrian J.

    2016-01-01

    Study Objectives: Drugs and psychoactive substances can cause sleepiness and when undetected, may lead to over diagnosis of central hypersomnias. We performed urine drug testing using gas chromatography-mass spectrometry in adults undergoing multiple sleep latency testing (MSLT) for a suspected central hypersomnia. We examined how the drug test results modified the treating physician's diagnosis. Methods: One hundred eighty-six consecutive patients with a suspected central hypersomnia who underwent clinical assessment, MSLT and urine drug testing by gas chromatography-mass spectrometry were retrospectively studied. Physicians made a diagnosis after clinical assessment and MSLT and were initially blinded to the urine drug test results. Results: A third of patients assessed for subjective hypersomnia had a positive urine drug test for a substance affecting sleep. Opioids, cannabis, and amphetamines were the commonest drugs detected. Using MSLT, 35 (18.8%) of 186 patients had objective hypersomnia that may have been due to a drug or substance. Drugs or substances may have confounded the MSLT in 11 (20.1%) of 53 patients who fulfilled diagnostic criteria for idiopathic hypersomnia, and 12 (52%) of 23 of those who fulfilled diagnostic criteria for narcolepsy without cataplexy. Of the 75 positive urine drug samples, 61 (81%) were substances or medications not revealed in the physician interview. The treating physician had not suspected drugs or substances as a possible cause of objective hypersomnia in 34 (97%) of the 35 patients. Conclusions: Drugs and psychoactive substances can confound the results of the MSLT and when undetected could lead to over diagnosis of central hypersomnias. Citation: Kosky CA, Bonakis A, Yogendran A, Hettiarachchi G, Dargan PI, Williams AJ. Urine toxicology in adults evaluated for a central hypersomnia and how the results modify the physician's diagnosis. J Clin Sleep Med 2016;12(11):1499–1505. PMID:27568897

  6. Epidemiology of Schistosomiasis and Usefulness of Indirect Diagnostic Tests in School-Age Children in Cubal, Central Angola

    PubMed Central

    Bocanegra, Cristina; Gallego, Sara; Mendioroz, Jacobo; Moreno, Milagros; Sulleiro, Elena; Salvador, Fernando; Sikaleta, Nicolau; Nindia, Arlette; Tchipita, Daniel; Joromba, Morais; Kavaya, Sebastiao; Sánchez Montalvá, Adrián; López, Teresa; Molina, Israel

    2015-01-01

    Introduction Schistosomiasis remains a public health major problem and little is known in many areas, mainly in Sub-Saharan Africa Objectives To assess the burden and risk factors of schistosomiasis and intestinal parasitic helminthes in the children of Cubal, Angola, and to compare different diagnostic approaches for urinary schistosomiasis under field conditions. Methods A cross-sectional study was conducted. Urine and faeces samples of school children were microscopically studied. A random sample of children was obtained from an alphabetically arranged list of children, taking one of two children. Urine dipstick, colorimetric test and macrohaematuria were considered as indirect diagnostic methods and compared to direct urine examination. Possible risk factors for the infection were sex, age, distance to the river and previous treatment with praziquantel; the assessment was performed using Chi-square test. Results A total of 785 (61.18%) children showed S. haematobium eggs in urine; children living within 500 meters from the river had a higher odds for infection: Odds ratio 1.97 (1.45–2.7 CI 95%); urine dipstick showed sensitivity of 96% and specificity of 61.3%, with a positive predictive value; colorimetric test showed sensitivity of 52.5%, specificity of 74.6% and a positive predictive value of 77%. Proteinuria was present in 653 (51.1%) children, being more frequent in children with S. haematobium in urine (75.2%); 32 of 191 stool samples (16%) showed the presence of other intestinal parasites and 8 (4%) for S. haematobium. Conclusions Prevalence of urinary schistosomiasis in our study area is much higher than the national average, considering it as a high-risk community. Proximity to a source of water was a risk factor for the infection. Indirect tests, as urine dipstick and colorimetric test, were useful tools for diagnosis, due to ease of use and low cost. Proteinuria was a common finding, probably showing an early structural damage due to schistosomiasis in this group of children. PMID:26474169

  7. Compatibility Testing of Polymeric Materials for the Urine Processor Assembly (UPA) of International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    Wingard, Charles D.

    2003-01-01

    In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA) by a distillation process. The urine is pre-treated, containing flush water and stabilizers. About 2.5% solids in the urine are concentrated up to 16% brine through distillation. Dynamic mechanical analysis (DMA) in the stress relaxation mode was primarily used to test 15 polymeric UPA materials for compatibility with the pre-treated and brine solutions. There were concerns that chromium trioxide (CrO3), a stabilizer not in the original pre-treat formulation for similar compatibility testing in 2000, could have an adverse effect on these polymers. DMA testing is partially complete for polymeric material samples immersed in the two solutions at room temperature for as long as 200 days. By comparing each material (conditioned and virgin), the stress relaxation modulus (E) was determined for short-term use and predicted for as long as a 10-year use in space. Such a delta E showed a decrease of as much as 79% for a Nylon material, but an increase as much as 454% for a polysulfone material, with increasing immersion time.

  8. Microbiological and corrosion analysis of three urine pretreatment regimes with titanium 6A1-4V

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1993-01-01

    One objective of the water recovery test (WRT) performed at NASA's Marshall Space Flight Center (MSFC) for the environmental control and life support systems (ECLSS) of Space Station Freedom is to determine the ability of the water recovery system to reclaim urine for crew reuse. In the process, raw urine is pretreated using a commercially available oxidant, Oxone (Dupont), and sulfuric acid (to reduce ammonia), and pumped into a urine processing subsystem. A combination of sodium hypochlorite and sulfuric acid were also considered as an alternative pretreatment. The ability of these pretreatments, plus a third pretreatment of ozone, to reduce microbial levels in urine generated during testing of the water recovery system at MSFC was examined. In addition, the corrosion rate of weld and base metal specimens of titanium 6A1-4V, a candidate material for the water system of Space Station Freedom, was monitored in the presence of these pretreatments. Specimen surfaces were examined at completion of the 21-day test using scanning electron microscopy. Change in pH, color, turbidity, and odor were recorded over the course of the test.

  9. HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries.

    PubMed

    Frati, Elena Rosanna; Martinelli, Marianna; Fasoli, Ester; Colzani, Daniela; Bianchi, Silvia; Binda, Sandro; Olivani, Pierfranco; Tanzi, Elisabetta

    2015-01-01

    Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV) testing from dried urine spots (DUS). Eighty-eight urine samples (including 56 HPV DNA positive specimens) were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR) assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56-99.68) for DUS stored for 1 week and 96.42% (95% CI: 87.88-99.01) for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28-100) at both time points. The concordance between DUS and fresh urine HPV testing was "almost perfect" using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries.

  10. HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries

    PubMed Central

    Olivani, Pierfranco

    2015-01-01

    Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV) testing from dried urine spots (DUS). Eighty-eight urine samples (including 56 HPV DNA positive specimens) were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR) assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56–99.68) for DUS stored for 1 week and 96.42% (95% CI: 87.88–99.01) for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28–100) at both time points. The concordance between DUS and fresh urine HPV testing was “almost perfect” using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries. PMID:26180790

  11. Fast screening tests for the simultaneous detection of 11 drugs of abuse in urine specimens. A forensic epidemiology study of 28,298 cases in Tunisia.

    PubMed

    Moslah, B; Araoud, M; Nouioui, M A; Najjar, S; Amira, D; Ben Salah, N; Hedhili, A

    2018-02-01

    Forensic investigation performed on people suspected to be drug abusers covering all Tunisian cities was conducted by monitoring an epidemiological study of human urine samples surveying positive rates of consumption for drugs of abuse. The forensic investigations were conducted on a total of 28,298 arrested individuals suspected to be drug addicts during five years (January 2010-December 2015). An immunoassay screening tests to detect elevated levels of drugs classes in urine samples was performed. These screening assays provide a preliminary qualitative test result. Only positives urine specimens were analyzed with GC-MS for confirmation. Except for cannabis, the results showed insignificant number of positive cases for cocaine, ecstasy (MDMA) and amphetamine consumptions (<1%). Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Urine test could become early detection device.

    PubMed

    1999-03-01

    Researchers at the Clinical Reference Laboratory in Kansas have detected HIV antibodies in the urine of 24 low-risk people who tested negative for HIV in blood tests. These people are presumed to have been exposed to the virus, but it is not known yet if they actually carry the infection. It is possible for the virus and its antibodies to appear in the urogenital tract before spreading to the bloodstream. If this is correct, the urine test could become a way to screen high-risk individuals, who as a result may be able to initiate highly active antiretroviral therapy (HAART) before the infection becomes systemic. Study results will be presented at the American Association of Clinical Chemists meeting.

  13. Leukocyte counts in urine reflect the risk of concomitant sepsis in bacteriuric infants: a retrospective cohort study.

    PubMed

    Bonsu, Bema K; Harper, Marvin B

    2007-06-13

    When urine infections are missed in febrile young infants with normal urinalysis, clinicians may worry about the risk--hitherto unverified--of concomitant invasion of blood and cerebrospinal fluid by uropathogens. In this study, we determine the extent of this risk. In a retrospective cohort study of febrile 0-89 day old infants evaluated for sepsis in an urban academic pediatric emergency department (1993-1999), we estimated rates of bacteriuric sepsis (urinary tract infections complicated by sepsis) after stratifying infants by urine leukocyte counts higher, or lower than 10 cells/hpf. We compared the global accuracy of leukocytes in urine, leukocytes in peripheral blood, body temperature, and age for predicting bacteruric sepsis. The global accuracy of each test was estimated by calculating the area under its receiver operating characteristic curve (AUC). Chi-square and Fisher exact tests compared count data. Medians for data not normally distributed were compared by the Kruskal-Wallis test. Two thousand two hundred forty-nine young infants had a normal screening dipstick. None of these developed bacteremia or meningitis despite positive urine culture in 41 (1.8%). Of 1516 additional urine specimens sent for formal urinalysis, 1279 had 0-9 leukocytes/hpf. Urine pathogens were isolated less commonly (6% vs. 76%) and at lower concentrations in infants with few, compared to many urine leukocytes. Urine leukocytes (AUC: 0.94) were the most accurate predictors of bacteruric sepsis. Infants with urinary leukocytes < 10 cells/hpf were significantly less likely (0%; CI:0-0.3%) than those with higher leukocyte counts (5%; CI:2.6-8.7%) to have urinary tract infections complicated by bacteremia (N = 11) or bacterial meningitis (N = 1)--relative risk, 0 (CI:0-0.06) [RR, 0 (CI: 0-0.02), when including infants with negative dipstick]. Bands in peripheral blood had modest value for detecting bacteriuric sepsis (AUC: 0.78). Cases of sepsis without concomitant bacteriuria were comparatively rare (0.8%) and equally common in febrile young infants with low and high concentrations of urine leukocytes. In young infants evaluated for fever, leukocytes in urine reflect the likelihood of bacteriuric sepsis. Infants with urinary tract infections missed because of few leukocytes in urine are at relatively low risk of invasive bacterial sepsis by pathogens isolated from urine.

  14. Reversion of High-level Mecillinam Resistance to Susceptibility in Escherichia coli During Growth in Urine.

    PubMed

    Thulin, Elisabeth; Thulin, Måns; Andersson, Dan I

    2017-09-01

    Mecillinam (amdinocillin) is a β-lactam antibiotic used to treat uncomplicated urinary tract infections (UTIs). We have previously shown that inactivation of the Escherichia coli cysB gene is the major cause of mecillinam resistance (Mec R ) in clinical isolates. In this study, we used different E. coli strains (laboratory and clinical isolates) that were Mec R due to cysB mutations to determine how mecillinam susceptibility was affected during growth in urine compared to growth in the commonly used growth medium Mueller Hinton (MHB). We also examined mecillinam susceptibility when bacteria were grown in urine obtained from 48 different healthy volunteers. Metabolome analysis was done on the urine samples and the association between the mecillinam susceptibility patterns of the bacteria and urine metabolite levels was studied. Two major findings with clinical significance are reported. First, Mec R E. coli cysB mutant strains (both laboratory and clinical isolates) were always more susceptible to mecillinam when grown in urine as compared to laboratory medium, with many strains showing complete phenotypic susceptibility in urine. Second, the degree of reversion to susceptibility varied between urine samples obtained from different individuals. This difference was correlated with osmolality such that in urine with low osmolality the Mec R mutants were more susceptible to mecillinam than in urine with high osmolality. This is the first example describing conditional resistance where a genetically stable antibiotic resistance can be phenotypically reverted to susceptibility by metabolites present in urine. These findings have several important clinical implications regarding the use of mecillinam to treat UTIs. First, they suggest that mecillinam can be used to treat also those clinical strains that are identified as Mec R in standard laboratory tests. Second, the results suggest that testing of mecillinam susceptibility in the laboratory ought to be performed in media that mimics urine to obtain clinically relevant susceptibility testing results. Third, these findings imply that changes in patient behavior, such as increased water intake or use of diuretics to reduce urine osmolality and increased intake of cysteine, might induce antibiotic susceptibility in an infecting Mec R E. coli strain and thereby increase treatment efficiency. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Pilot-Plant Demonstration of Wet Oxidation for Treatment of Shipboard Wastewaters.

    DTIC Science & Technology

    1975-11-01

    minus mg of COD removed in prior sampling )] Table I indicates that, when the reactor was last sampled after six injections Pf concentrated feces and urine ...oxidation of feces and urine is of an inorganic nature. The pH of most of the samples taken in thes tests was measured using indi- cator papers. All...BATCH EXPERIMENTS ON FECES AND URINE IN rRESENCE OF BARBER-COLMAN CO. CATALYST 10,480 ............. . E.1 lest Procedure ......... . E-3 E.2 Test

  16. Lower Cutoffs for LC-MS/MS Urine Drug Testing Indicates Better Patient Compliance.

    PubMed

    Krock, Kevin; Pesce, Amadeo; Ritz, Dennis; Thomas, Richard; Cua, Agnes; Rogers, Ryan; Lipnick, Phil; Kilbourn, Kristen

    2017-11-01

    Urine drug testing is used by health care providers to determine a patient's compliance to their prescribed regimen and to detect non-prescribed medications and illicit drugs. However, the cutoff levels used by clinical labs are often arbitrarily set and may not reflect the urine drug concentrations of compliant patients. Our aim was to test the hypothesis that commonly used cutoffs for many prescribed and illicit drugs were set too high, and methods using these cutoffs may yield a considerable number of false-negative results. The goals of this study were to outline the way to analyze patient results and estimate a more appropriate cutoff, develop and validate a high sensitivity analytical method capable of quantitating drugs and metabolites at lower than the commonly used cutoffs, and determine the number of true positive results that would have been missed when using the common cutoffs. This was a retrospective study of urine specimens submitted for urine drug testing as part of the monitoring of prescription drug compliance described in chronic opioid therapy treatment guidelines. The study was set in a clinical toxicology laboratory, using specimens submitted for routine analysis by health care providers in the normal course of business. Lognormal distributions of test results were generated and fitted with a trendline to estimate the required cutoff level necessary to capture the normal distributions of each drug for the patient population study. A validated laboratory derived liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis capable of achieving the required cutoff levels was developed for each drug and/or metabolite. The study shows that a lognormal distribution of patient urine test results fitted with a trendline is appropriate for estimating the required cutoff levels needed to assess medication adherence. The study showed a wide variation in the false-negative rate, ranging from 1.5% to 94.3% across a range of prescribed and illicit drugs. The patient specimens were largely sourced from patients in either a long-term pain management program or in treatment for substance use disorder in the US. These specimens may not be representative of patients in other types of treatment or in countries with different approaches to these issues. The high-sensitivity method reduces false-negative results which could negatively impact patient care. Clinicians using less sensitive methods for detecting and quantifying drugs and metabolites in urine should exercise caution in assessing patient adherence using and changing the treatment plan based on those results. Urine drug testing, patient adherence, clinical toxicology, immunoassay, LC-MS, definitive drug testing, REMS, negative test results, false negative.

  17. Results of hair analyses for drugs of abuse and comparison with self-reports and urine tests.

    PubMed

    Musshoff, F; Driever, F; Lachenmeier, K; Lachenmeier, D W; Banger, M; Madea, B

    2006-01-27

    Urine as well as head and pubic hair samples from drug abusers were analysed for opiates, cocaine and its metabolites, amphetamines, methadone and cannabinoids. Urine immunoassay results and the results of hair tests by means of gas chromatography-mass spectrometry were compared to the self-reported data of the patients in an interview protocol. With regard to the study group, opiate abuse was claimed from the majority in self-reports (89%), followed by cannabinoids (55%), cocaine (38%), and methadone (32%). Except for opiates the comparison between self-reported drug use and urinalysis at admission showed a low correlation. In contrast to urinalysis, hair tests revealed consumption in more cases. There was also a good agreement between self-reports of patients taking part in an official methadone maintenance program and urine test results concerning methadone. However, hair test results demonstrated that methadone abuse in general was under-reported by people who did not participate in a substitution program. Comparing self-reports and the results of hair analyses drug use was dramatically under-reported, especially cocaine. Cocaine hair tests appeared to be highly sensitive and specific in identifying past cocaine use even in settings of negative urine tests. In contrast to cocaine, hair lacks sensitivity as a detection agent for cannabinoids and a proof of cannabis use by means of hair analysis should include the sensitive detection of the metabolite THC carboxylic acid in the lower picogram range.

  18. Ketogenic diet metabolites reduce firing in central neurons by opening K(ATP) channels.

    PubMed

    Ma, Weiyuan; Berg, Jim; Yellen, Gary

    2007-04-04

    A low-carbohydrate ketogenic diet remains one of the most effective (but mysterious) treatments for severe pharmacoresistant epilepsy. We have tested for an acute effect of physiological ketone bodies on neuronal firing rates and excitability, to discover possible therapeutic mechanisms of the ketogenic diet. Physiological concentrations of ketone bodies (beta-hydroxybutyrate or acetoacetate) reduced the spontaneous firing rate of neurons in slices from rat or mouse substantia nigra pars reticulata. This region is thought to act as a "seizure gate," controlling seizure generalization. Consistent with an anticonvulsant role, the ketone body effect is larger for cells that fire more rapidly. The effect of ketone bodies was abolished by eliminating the metabolically sensitive K(ATP) channels pharmacologically or by gene knock-out. We propose that ketone bodies or glycolytic restriction treat epilepsy by augmenting a natural activity-limiting function served by K(ATP) channels in neurons.

  19. Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice

    PubMed Central

    Schot, Marjolein J C; van Delft, Sanne; Kooijman-Buiting, Antoinette M J; de Wit, Niek J; Hopstaken, Rogier M

    2015-01-01

    Objective Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. Setting All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Primary and secondary outcome measures Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. Results The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. Conclusions The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice. PMID:25986635

  20. Impaired insight in cocaine addiction: laboratory evidence and effects on cocaine-seeking behaviour

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moeller, S.J.; Moeller, S.J.; Maloney, T.

    Neuropsychiatric disorders are often characterized by impaired insight into behaviour. Such an insight deficit has been suggested, but never directly tested, in drug addiction. Here we tested for the first time this impaired insight hypothesis in drug addiction, and examined its potential association with drug-seeking behaviour. We also tested potential modulation of these effects by cocaine urine status, an individual difference known to impact underlying cognitive functions and prognosis. Sixteen cocaine addicted individuals testing positive for cocaine in urine, 26 cocaine addicted individuals testing negative for cocaine in urine, and 23 healthy controls completed a probabilistic choice task that assessedmore » objective preference for viewing four types of pictures (pleasant, unpleasant, neutral and cocaine). This choice task concluded by asking subjects to report their most selected picture type; correspondence between subjects self-reports with their objective choice behaviour provided our index of behavioural insight. Results showed that the urine positive cocaine subjects exhibited impaired insight into their own choice behaviour compared with healthy controls; this same study group also selected the most cocaine pictures (and fewest pleasant pictures) for viewing. Importantly, however, it was the urine negative cocaine subjects whose behaviour was most influenced by insight, such that impaired insight in this subgroup only was associated with higher cocaine-related choice on the task and more severe actual cocaine use. These findings suggest that interventions to enhance insight may decrease drug-seeking behaviour, especially in urine negative cocaine subjects, potentially to improve their longer-term clinical outcomes.« less

  1. 49 CFR 40.33 - What training requirements must a collector meet?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...

  2. 49 CFR 40.33 - What training requirements must a collector meet?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...

  3. 49 CFR 40.33 - What training requirements must a collector meet?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...

  4. 49 CFR 40.33 - What training requirements must a collector meet?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...

  5. 49 CFR 40.33 - What training requirements must a collector meet?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...

  6. Urine sampling and collection system

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.

    1971-01-01

    This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.

  7. 10 CFR 26.109 - Urine specimen quantity.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine... shall encourage the donor to drink a reasonable amount of liquid (normally, 8 ounces of water every 30...

  8. 10 CFR 26.109 - Urine specimen quantity.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine... shall encourage the donor to drink a reasonable amount of liquid (normally, 8 ounces of water every 30...

  9. 10 CFR 26.109 - Urine specimen quantity.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine... shall encourage the donor to drink a reasonable amount of liquid (normally, 8 ounces of water every 30...

  10. Urine pH test

    MedlinePlus

    ... 2015:chap 4. Remer T, Manz F. Potential renal acid load of foods and its influence on urine pH. J Am Diet Assoc . 1995;95(7):791-797. PMID: 7797810 www.ncbi.nlm.nih.gov/pubmed/7797810 . Riley RS, McPherson RA. Basic examination of urine. In: McPherson RA, Pincus MR, ...

  11. 10 CFR 26.105 - Preparing for urine collection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer...

  12. 10 CFR 26.113 - Splitting the urine specimen.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split...

  13. 10 CFR 26.115 - Collecting a urine specimen under direct observation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures for...

  14. 10 CFR 26.113 - Splitting the urine specimen.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split...

  15. 10 CFR 26.115 - Collecting a urine specimen under direct observation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures for...

  16. 10 CFR 26.115 - Collecting a urine specimen under direct observation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures for...

  17. 10 CFR 26.113 - Splitting the urine specimen.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split...

  18. 10 CFR 26.105 - Preparing for urine collection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer...

  19. 10 CFR 26.105 - Preparing for urine collection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer...

  20. 10 CFR 26.109 - Urine specimen quantity.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine specimen quantity. (a) Licensees and other entities who are subject to this subpart shall establish a...

  1. 10 CFR 26.115 - Collecting a urine specimen under direct observation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures for...

  2. 10 CFR 26.113 - Splitting the urine specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split...

  3. 10 CFR 26.115 - Collecting a urine specimen under direct observation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures for...

  4. 10 CFR 26.105 - Preparing for urine collection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer...

  5. 10 CFR 26.105 - Preparing for urine collection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer...

  6. 10 CFR 26.109 - Urine specimen quantity.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine specimen quantity. (a) Licensees and other entities who are subject to this subpart shall establish a...

  7. 10 CFR 26.113 - Splitting the urine specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split...

  8. 49 CFR 40.195 - What happens when an individual is unable to provide a sufficient amount of urine for a pre...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... provide a sufficient amount of urine for a pre-employment follow-up or return-to-duty test because of a... providing a sufficient specimen for a pre-employment follow-up or return-to-duty test and the condition... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests...

  9. 49 CFR 40.195 - What happens when an individual is unable to provide a sufficient amount of urine for a pre...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... provide a sufficient amount of urine for a pre-employment follow-up or return-to-duty test because of a... providing a sufficient specimen for a pre-employment follow-up or return-to-duty test and the condition... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests...

  10. 49 CFR 40.195 - What happens when an individual is unable to provide a sufficient amount of urine for a pre...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... provide a sufficient amount of urine for a pre-employment follow-up or return-to-duty test because of a... providing a sufficient specimen for a pre-employment follow-up or return-to-duty test and the condition... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests...

  11. 49 CFR 40.195 - What happens when an individual is unable to provide a sufficient amount of urine for a pre...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... provide a sufficient amount of urine for a pre-employment follow-up or return-to-duty test because of a... providing a sufficient specimen for a pre-employment follow-up or return-to-duty test and the condition... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests...

  12. 49 CFR 40.195 - What happens when an individual is unable to provide a sufficient amount of urine for a pre...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... provide a sufficient amount of urine for a pre-employment follow-up or return-to-duty test because of a... providing a sufficient specimen for a pre-employment follow-up or return-to-duty test and the condition... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests...

  13. Detection of Circulating Paracoccidioides brasiliensis Antigen in Urine of Paracoccidioidomycosis Patients before and during Treatment

    PubMed Central

    Salina, Margarete Aparecida; Shikanai-Yasuda, Maria Aparecida; Mendes, Rinaldo Poncio; Barraviera, Benedito; Mendes Giannini, Maria José Soares

    1998-01-01

    For the diagnosis and follow-up of paracoccidioidomycosis patients undergoing therapy, we evaluated two methods (immunoblotting and competition enzyme immunoassay) for the detection of circulating antigen in urine samples. A complex pattern of reactivity was observed in the immunoblot test. Bands of 70 and 43 kDa were detected more often in urine samples from patients before treatment. The immunoblot method detected gp43 and gp70 separately or concurrently in 11 (91.7%) of 12 patients, whereas the competition enzyme immunoassay detected antigenuria in 9 (75%) of 12 patients. Both tests appeared to be highly specific (100%), considering that neither fraction detectable by immunoblotting was present in urine samples from the control group. gp43 remained present in the urine samples collected during the treatment period, with a significant decrease in reactivity in samples collected during clinical recovery and increased reactivity in samples collected during relapses. Reactivity of some bands was also detected in urine specimens from patients with “apparent cure.” The detection of Paracoccidioides brasiliensis antigens in urine appears to be a promising method for diagnosing infection, for evaluating the efficacy of treatment, and for detecting relapse. PMID:9620407

  14. [Identification of Methamphetamine Abuse and Selegiline Use: Chiral Analysis of Methamphetamine and Amphetamine in Urine].

    PubMed

    Xiang, P; Bu, J; Qiao, Z; Zhuo, X Y; Wu, H J; Shen, M

    2017-12-01

    To study the content variation of selegiline and its metabolites in urine, and based on actual cases, to explore the feasibility for the identification of methamphetamine abuse and selegiline use by chiral analysis. The urine samples were tested by chiral separation and LC-MS/MS method using CHIROBIOTIC™ V2 chiral liquid chromatography column. The chiral analysis of methamphetamine and amphetamine were performed on the urine samples from volunteers of selegiline use and drug addicts whom suspected taking selegiline. After 5 mg oral administration, the positive test time of selegiline in urine was less than 7 h. The mass concentrations of R(-)-methamphetamine and R(-)-amphetamine in urine peaked at 7 h which were 0.86 μg/mL and 0.18 μg/mL and couldn't be detected after 80 h and 168 h, respectively. The sources of methamphetamine and amphetamine in the urine from the drug addicts whom suspected taking selegiline were analysed successfully by present method. The chiral analysis of methamphetamine and amphetamine, and the determination of selegiline's metabolites can be used to distinguish methamphetamine abuse from selegiline use. Copyright© by the Editorial Department of Journal of Forensic Medicine

  15. Treatment Option Overview (Adrenocortical Carcinoma)

    MedlinePlus

    ... if you have any of these problems. Imaging studies and tests that examine the blood and urine are used ... urine that is collected for three days. This test is done to check if the adrenal gland is ... Blood chemistry study : A procedure in which a blood sample is ...

  16. Stages of Adrenocortical Carcinoma

    MedlinePlus

    ... if you have any of these problems. Imaging studies and tests that examine the blood and urine are used ... urine that is collected for three days. This test is done to check if the adrenal gland is ... Blood chemistry study : A procedure in which a blood sample is ...

  17. APPLICATION OF NONINVASIVE PREGNANCY DIAGNOSIS IN BACTRIAN CAMELS (CAMELUS BACTRIANUS) USING CUBONI REACTION AND BARIUM CHLORIDE TEST.

    PubMed

    Fedorova, Tamara; Brandlová, Karolína; Lukešová, Daniela

    2015-06-01

    Pregnancy diagnoses in half-tamed animals are often very complicated. This study aimed to examine the alternative noninvasive and cheap methods of pregnancy diagnosis from urine in domestic Bactrian camels (Camelus bactrianus). Urine from 14 female camels kept in four European zoologic gardens was collected and tested by two chemical tests--Cuboni reaction and barium chloride test. The Cuboni reaction was significantly (P<0.01) affected by the pregnancy status of female camels. The total accuracy of the Cuboni reaction was 70.5% but it increased significantly (P<0.05) in the time leading up to parturition. The accuracy was 100% in the 3rd third of pregnancy. Urine of nonpregnant females did not react with a solution of barium chloride while, contrary to other studies, white precipitates formed mostly (80 to 100%) in urine of pregnant females. This study concluded that the Cuboni reaction is applicable for pregnancy diagnosis in camels.

  18. Consideration of the degree of increase in urine metadrenalines provides superior specificity in the diagnosis of phaeochromocytoma than additional urine catecholamine measurement.

    PubMed

    Scargill, J J; Reed, P; Kane, J

    2013-01-01

    Measurement of fractionated plasma or urine metadrenalines is the recommended screening test in the diagnosis of phaeochromocytoma, with clinical cut-offs geared towards diagnostic sensitivity. Current practice at Salford Royal Hospital is to add urine catecholamines onto samples with raised urine metadrenalines, with the aim of adding specificity to a diagnosis of phaeochromocytoma. This practice was reviewed by identifying a series of patients with raised urine metadrenalines who had catecholamines reflectively added. A total of 358 samples were identified from 242 patients, of which 228 had urine catecholamines measured. A diagnosis of 'phaeochromocytoma' (n = 41) or 'no phaeochromocytoma' (n = 90) was obtained in 131 of 228 patients, giving raised urine metadrenalines a positive predictive value for phaeochromocytoma of 31%. The finding of increased urine catecholamines in samples with raised urine metadrenalines increased specificity for phaeochromocytoma to 70%. However, 95% diagnostic specificity for phaeochromocytoma could be achieved by the introduction of a second cut-off for urine metadrenalines geared towards maximizing specificity. Consideration of the degree of increase in urine metadrenalines is a superior method of determining the likelihood of phaeochromocytoma than measurement of urine catecholamines.

  19. Profile of children with urinary tract infection and the utility of urine dipstick as a diagnostic tool.

    PubMed

    Ojha, A R; Aryal, U R

    2014-01-01

    Urinary tract infection is a common problem in children and its early diagnosis and treatment is important to prevent long-term complications. Urine dipstick can be an important tool in this respect. The aim of this study is to look at the utility of urine dipstick as a diagnostic tool for UTI and will also see the clinical profile of children with UTI and sensitivity pattern of antibiotics among the isolates of urine culture. Urine samples of all children below 14 years of age who were suspected of urinary tract infection were sent for routine microscopic examination and dipstick testing. Urine culture and sensitivity were sent for those samples that were tested positive for nitrite, leucocyte esterase activity or both. For every fifth sample, which is dipstick negative, a culture and sensitivity testing was done. Among 110 children enrolled, 32(29%) cases had significant bacteriuria. Out of 32 culture positive cases 18(56%) were female. Fever was the main complaint (62.5%)). Escherichia Coli was isolated in 81.25% of cases. Amikacin was sensitive in 93% and amoxicillinwas resistant in 82%. The sensitivity, specificity, positive predictive value, negative predictive value of nitrite test was 65%, 80%, 58%, 85% respectively; those of leucocyte esterase are 84%, 55%, 43%, 89% respectively; those for significant microscopic pyuria >10/hpf were 65%, 74%, 51%, 84% respectively. E. Coli is the commonest uropathogen in children with UTI. Amikacin is the most sensitive antibiotic against all the isolates. A positive dipstick both for nitrite and leucocyte esterase is associated with high sensitivity and specificity for urinary tract infection as compared to either of them positive alone. In addition, urine WBC ≥10/hpf is associated with high probability of UTI.

  20. [The incidence and risk factors of male urinary tract infection following invasive urodynamic investigation].

    PubMed

    Huang, Zhongming; Li, Hanzhong; Ji, Zhigang; Xiao, He

    2015-11-10

    To assess the prevalence of male urinary tract infection (UTI) after invasive urodynamic studies and to determinate the risk factors by evaluating the clinical characteristics and urodynamic parameters of patients. Six hundred and seventy-one consecutive men were recruited. All patients accepted urine routine tests and(or)urine culture three times. The first culture and routine tests were carried out in the 2 to 4 weeks before urodynamic studies by using clean-catch midstream urine (MSU) or catheter urine specimen. The second urine routine test was carried out at the start of examinations and the last urine culture were carried out in 48-72 hours after the investigations. Male patients with negative results (leucocytes <15 cells/ul and <10(5) colony-forming units per milliliter [cfu/ml]) in 1(st) and 2(nd) time received a standard urodynamic investigation. The investigations of the remaining patients were postponed until the urinary tract infection had been treated. The prevalence of urinary tract infection before urodynamic investigation (with positive results in 1(st) and 2(nd) urine test) was 7.3%, and the prevalence after the investigation in patients without UTI before examination was 10.3%. Bladder outlet obstruction (BOO), age ≥ 65 years, and diabetes were the risk factors for UTI after urodynamic investigation. The most common uropathogens in the urinary tract infections after the urodynamic investigation were Escherichia coli (53.1%, 34/64) and Enterococcus faecalis (17.2%, 11/64). Despite a stringent standard operation protocol, the prevalence of UTI in male patients caused by urodynamic examination is about 10%. For the high-risk patients with BOO, older age, and diabetes, prophylactic antibiotic treatment before or after procedure may be necessary.

  1. Effect of urine creatinine level during pregnancy on dipstick test.

    PubMed

    Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori

    2017-06-01

    Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.

  2. Rational use and interpretation of urine drug testing in chronic opioid therapy.

    PubMed

    Reisfield, Gary M; Salazar, Elaine; Bertholf, Roger L

    2007-01-01

    Urine drug testing (UDT) has become an essential feature of pain management, as physicians seek to verify adherence to prescribed opioid regimens and to detect the use of illicit or unauthorized licit drugs. Results of urine drug tests have important consequences in regard to therapeutic decisions and the trust between physician and patient. However, reliance on UDT to confirm adherence can be problematic if the results are not interpreted correctly, and evidence suggests that many physicians lack an adequate understanding of the complexities of UDT and the factors that can affect test results. These factors include metabolic conversion between drugs, genetic variations in drug metabolism, the sensitivity and specificity of the analytical method for a particular drug or metabolite, and the effects of intentional and unintentional interferants. In this review, we focus on the technical features and limitations of analytical methods used for detecting drugs or their metabolites in urine, the statistical constructs that are pertinent to ordering UDT and interpreting test results, and the application of these concepts to the clinical monitoring of patients maintained on chronic opioid therapy.

  3. Screening and treating asymptomatic bacteriuria in pregnancy.

    PubMed

    Lumbiganon, Pisake; Laopaiboon, Malinee; Thinkhamrop, Jadsada

    2010-04-01

    Asymptomatic bacteriuria (ASB) in pregnancy, if left undiagnosed and appropriately treated can lead to acute pyelonephritis in mothers and low birth weight in infants. Urine culture is the gold standard for diagnosing ASB. Unfortunately, urine culture is limitedly available. The present review aims at evaluating performance of various screening tests and effectiveness of antibiotic regimens for ASB. Positive dipslide test is very likely to have a definitive diagnosis of ASB, whereas a negative result effectively rules out ASB. Available evidences regarding the performance of urine dipstick are still conflicting, it is currently not appropriate to recommend urine dipstick for screening ASB in pregnancy. Choice of antibiotics should be guided by antimicrobial susceptibility testing whenever possible. Nitrofurantoin seems to be antibiotic of choice for ASB in pregnancy. Seven-day regimen of antibiotics gives a better microbiological cure rate but no difference in important clinical outcomes compared with 1-day regimen. Dipslide culture is a promising screening test for ASB. Pregnant women with ASB should be treated with 7-day regimen of antibiotics, although 1-day regimen might be appropriate in some settings. More research is needed for identifying appropriate screening tests for ASB.

  4. Urine podocyte mRNAs mark disease activity in IgA nephropathy

    PubMed Central

    Fukuda, Akihiro; Sato, Yuji; Iwakiri, Takashi; Komatsu, Hiroyuki; Kikuchi, Masao; Kitamura, Kazuo; Wiggins, Roger C.; Fujimoto, Shouichi

    2015-01-01

    Background Podocyte depletion is a major mechanism driving glomerulosclerosis. We and others have previously projected from model systems that podocyte-specific mRNAs in the urine pellet might serve as glomerular disease markers. We evaluated IgA nephropathy (IgAN) to test this concept. Methods From 2009 to 2013, early morning voided urine samples and kidney biopsies from IgAN patients (n = 67) were evaluated in comparison with urine samples from healthy age-matched volunteers (n = 28). Urine podocyte (podocin) mRNA expressed in relation to either urine creatinine concentration or a kidney tubular marker (aquaporin 2) was tested as markers. Results Urine podocyte mRNAs were correlated with the severity of active glomerular lesions (segmental glomerulosclerosis and acute extracapillary proliferation), but not with non-glomerular lesions (tubular atrophy/interstitial fibrosis) or with clinical parameters of kidney injury (serum creatinine and estimated glomerular filtration rate), or with degree of accumulated podocyte loss at the time of biopsy. In contrast, proteinuria correlated with all histological and clinical markers. Glomerular tuft podocyte nuclear density (a measure of cumulative podocyte loss) correlated with tubular atrophy/interstitial fibrosis, estimated-glomerular filtration rate and proteinuria, but not with urine podocyte markers. In a subset of the IgA cohort (n = 19, median follow-up period = 37 months), urine podocyte mRNAs were significantly decreased after treatment, in contrast to proteinuria which was not significantly changed. Conclusions Urine podocyte mRNAs reflect active glomerular injury at a given point in time, and therefore provide both different and additional clinical information that can complement proteinuria in the IgAN decision-making paradigm. PMID:25956757

  5. Water-loss (intracellular) dehydration assessed using urinary tests: how well do they work? Diagnostic accuracy in older people.

    PubMed

    Hooper, Lee; Bunn, Diane K; Abdelhamid, Asmaa; Gillings, Rachel; Jennings, Amy; Maas, Katie; Millar, Sophie; Twomlow, Elizabeth; Hunter, Paul R; Shepstone, Lee; Potter, John F; Fairweather-Tait, Susan J

    2016-07-01

    Water-loss dehydration (hypertonic, hyperosmotic, or intracellular dehydration) is due to insufficient fluid intake and is distinct from hypovolemia due to excess fluid losses. Water-loss dehydration is associated with poor health outcomes such as disability and mortality in older people. Urine specific gravity (USG), urine color, and urine osmolality have been widely advocated for screening for dehydration in older adults. We assessed the diagnostic accuracy of urinary measures to screen for water-loss dehydration in older people. This was a diagnostic accuracy study of people aged ≥65 y taking part in the DRIE (Dehydration Recognition In our Elders; living in long-term care) or NU-AGE (Dietary Strategies for Healthy Ageing in Europe; living in the community) studies. The reference standard was serum osmolality, and index tests included USG, urine color, urine osmolality, urine cloudiness, additional dipstick measures, ability to provide a urine sample, and the volume of a random urine sample. Minimum useful diagnostic accuracy was set at sensitivity and specificity ≥70% or a receiver operating characteristic plot area under the curve ≥0.70. DRIE participants (women: 67%; mean age: 86 y; n = 162) had more limited cognitive and functional abilities than did NU-AGE participants (women: 64%; mean age: 70 y; n = 151). Nineteen percent of DRIE participants and 22% of NU-AGE participants were dehydrated (serum osmolality >300 mOsm/kg). Neither USG nor any other potential urinary tests were usefully diagnostic for water-loss dehydration. Although USG, urine color, and urinary osmolality have been widely advocated for screening for dehydration in older adults, we show, in the largest study to date to our knowledge, that their diagnostic accuracy is too low to be useful, and these measures should not be used to indicate hydration status in older people (either alone or as part of a wider tranche of tests). There is a need to develop simple, inexpensive, and noninvasive tools for the assessment of dehydration in older people. The DRIE study was registered at www.researchregister.org.uk as 122273. The NU-AGE trial was registered at clinicialtrials.gov as NCT01754012. © 2016 American Society for Nutrition.

  6. Improved sensitivity of the urine CAA lateral-flow assay for diagnosing active Schistosoma infections by using larger sample volumes.

    PubMed

    Corstjens, Paul L A M; Nyakundi, Ruth K; de Dood, Claudia J; Kariuki, Thomas M; Ochola, Elizabeth A; Karanja, Diana M S; Mwinzi, Pauline N M; van Dam, Govert J

    2015-04-22

    Accurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction. Centrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test. Implementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay. Larger sample input increased Sn of the UCAA assay to a level indicating 'true' infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.

  7. Synthesis of Bridged Oligophenylene Laser Dyes

    DTIC Science & Technology

    1991-05-10

    the Grignard formation. Pure 22 as the free base could then be coulpled with the Grignard reagent from bromonaphthalene 20 using nickel acetoacetate as...preparation of 22 free of any positional isomer. We were able to prepare quite pure 22 by the Grignard coupling reaction of an excess p-chlorophenylmagnesium...fluorene 14 into the methoxyterphenyl 23 by the palladium-catalyzed Grignard coupling. Bromination of 23 was not clean as both the activated 7-position on

  8. Diagnostic yield of hair and urine toxicology testing in potential child abuse cases.

    PubMed

    Stauffer, Stephanie L; Wood, Stephanie M; Krasowski, Matthew D

    2015-07-01

    Detection of drugs in a child may be the first objective finding that can be reported in cases of suspected child abuse. Hair and urine toxicology testing, when performed as part of the initial clinical evaluation for suspected child abuse or maltreatment, may serve to facilitate the identification of at-risk children. Furthermore, significant environmental exposure to a drug (considered by law to constitute child abuse in some states) may be identified by toxicology testing of unwashed hair specimens. In order to determine the clinical utility of hair and urine toxicology testing in this population we performed a retrospective chart review on all children for whom hair toxicology testing was ordered at our academic medical center between January 2004 and April 2014. The medical records of 616 children aged 0-17.5 years were reviewed for injury history, previous medication and illicit drug use by caregiver(s), urine drug screen result (if performed), hair toxicology result, medication list, and outcome of any child abuse evaluation. Hair toxicology testing was positive for at least one compound in 106 cases (17.2%), with unexplained drugs in 82 cases (13.3%). Of these, there were 48 cases in which multiple compounds (including combination of parent drugs and/or metabolites within the same drug class) were identified in the sample of one patient. The compounds most frequently identified in the hair of our study population included cocaine, benzoylecgonine, native (unmetabolized) tetrahydrocannabinol, and methamphetamine. There were 68 instances in which a parent drug was identified in the hair without any of its potential metabolites, suggesting environmental exposure. Among the 82 cases in which hair toxicology testing was positive for unexplained drugs, a change in clinical outcome was noted in 71 cases (86.5%). Urine drug screens (UDS) were performed in 457 of the 616 reviewed cases. Of these, over 95% of positive UDS results could be explained by iatrogenic drug administration. There were no cases in which a urine drug screen alone altered the outcome of a case. In summary, hair toxicology testing proved clinically useful in the evaluation of a child for suspected abuse; in contrast, urine drug testing showed low clinical yield. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  9. Treatment Options by Stage (Adrenocortical Carcinoma)

    MedlinePlus

    ... if you have any of these problems. Imaging studies and tests that examine the blood and urine are used ... urine that is collected for three days. This test is done to check if the adrenal gland is ... Blood chemistry study : A procedure in which a blood sample is ...

  10. Determinants of practice patterns in pediatric UTI management.

    PubMed

    Selekman, R E; Allen, I E; Copp, H L

    2016-10-01

    Urinary tract infection (UTI) affects 10% of girls and 3% of boys by age 16. Both the American Academy of Pediatrics and National Institute for Health and Clinical Excellence Guidelines recommend urine testing prior to initiation of antibiotic treatment and the use of local antibiograms to guide empiric antibiotic therapy. Urine culture results not only provide the opportunity to halt empiric therapy if there is no bacterial growth, but also allow for tailoring of broad-spectrum therapy. Additionally, the use of antiobiograms improves empiric antibiotic selection based on local resistance patterns. However, execution of guideline recommendations has proved challenging. Understanding barriers in implementation is critical to developing targeted interventions aimed to improve adherence to these guidelines. The present study sought to investigate practice patterns and factors that influence urine testing and antibiogram use in the setting of empiric antibiotic treatment of UTI in children to ultimately improve adherence to UTI management guidelines. A random, national sample of physicians caring for children was surveyed from the American Medical Association Masterfile. Participants were queried regarding practice type, length of time in practice, factors influencing urine testing, urine specimen collection method, and antibiogram utilization. Logistic regression was used to assess factors associated with use of urine testing, bagged specimens, and antibiograms. Of respondents who acknowledged contact by surveyors, 47% completed the survey (n = 366). Most respondents (84%) obtain urinalysis and culture prior to treatment for UTI. Physicians report they would more likely order testing if the specimen were easier to collect (46%) and if results were available immediately (48%) (Table). Urine collection by bag was more common in circumcised boys (>30%) compared with girls (20%) and uncircumcised boys (20%) (P = 0.02). The most common reasons for collection by bag were parental refusal for (49%) and difficulty with (42%) catheterization (Table). Of the 70% of respondents reporting antibiogram access (n = 256), 50% report its use the majority of the time with empiric prescription (n = 128). While most practitioners report following guidelines to obtain urine testing prior to antibiotic prescription for UTI, urine collection by bag is common. Additionally, <50% of practitioners adhere to guideline recommendations for empiric antibiotic selection based on local antibiograms. Interventions to improve adherence to UTI management guidelines should focus on (1) improving catheterization practices, (2) educating parents regarding the value of catheterization, and (3) incorporating local antibiograms into electronic medical records. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  11. Automated color classification of urine dipstick image in urine examination

    NASA Astrophysics Data System (ADS)

    Rahmat, R. F.; Royananda; Muchtar, M. A.; Taqiuddin, R.; Adnan, S.; Anugrahwaty, R.; Budiarto, R.

    2018-03-01

    Urine examination using urine dipstick has long been used to determine the health status of a person. The economical and convenient use of urine dipstick is one of the reasons urine dipstick is still used to check people health status. The real-life implementation of urine dipstick is done manually, in general, that is by comparing it with the reference color visually. This resulted perception differences in the color reading of the examination results. In this research, authors used a scanner to obtain the urine dipstick color image. The use of scanner can be one of the solutions in reading the result of urine dipstick because the light produced is consistent. A method is required to overcome the problems of urine dipstick color matching and the test reference color that have been conducted manually. The method proposed by authors is Euclidean Distance, Otsu along with RGB color feature extraction method to match the colors on the urine dipstick with the standard reference color of urine examination. The result shows that the proposed approach was able to classify the colors on a urine dipstick with an accuracy of 95.45%. The accuracy of color classification on urine dipstick against the standard reference color is influenced by the level of scanner resolution used, the higher the scanner resolution level, the higher the accuracy.

  12. Urine and serum fetuin-A levels in patients with urolithiasis.

    PubMed

    Arora, Rajat; Abrol, Nitin; Antonisamy, B; Vanitha, S; Chandrasingh, J; Kumar, Santosh; Kekre, Nitin; Devasia, Antony

    2017-01-01

    Fetuin-A is a glycoprotein secreted by liver and has been shown to inhibit extraosseous mineralization. Urolithiasis may be a manifestation in the urinary tract due to fetuin deficiency in urine. The objective of this study was to compare the 24-h urine and serum fetuin-A levels of patients with and without urolithiasis. Serum and 24-h urine fetuin-A levels were measured in 41 patients with bilateral, multiple, or recurrent urinary tract calculi (Group A) and 41 matched controls with no calculi (Group B). Fetuin levels were measured by enzyme linked immunosorbent assay. Serum and urine fetuin-A levels in the two groups were compared. The median (range) 24-h urine fetuin-A value in Group A was 11.9 (1.12-221) mg/day and in Group B was 37.7 (1.28-125) mg/day. This difference was statistically significant (Mann-Whitney test, P = 0.0169). The median (range) serum fetuin-A in Group A was 0.67 (0.05-2.68) g/L and in Group B was 0.99 (0.01-5.5) g/L. The difference between serum values in the two arms was not statistically significant (Mann-Whitney test, P = 0.1817). However, the serum creatinine-adjusted mean log serum fetuin and urine fetuin were significantly different in the two arms ( P = 0.003). The mean ± standard deviation (range) serum creatinine in Group A was 0.98 ± 0.25 (0.56-1.58) mg% and in Group B was 0.83 ± 0.16 (0.58-1.18) mg% (two sample t -test, P = 0.0031). Patients with urolithiasis have lower urine fetuin-A and creatinine-adjusted serum fetuin-A levels.

  13. Urine Antigen Detection as an Aid to Diagnose Invasive Aspergillosis.

    PubMed

    Marr, Kieren A; Datta, Kausik; Mehta, Seema; Ostrander, Darin B; Rock, Michelle; Francis, Jesse; Feldmesser, Marta

    2018-04-19

    Establishing rapid diagnoses of invasive aspergillosis (IA) is priority, given poor outcomes of late therapy. Non-culture based tests that detect galactomannan and β-D glucan are available, but are technically cumbersome and rely on invasive sampling (blood or bronchoalveolar lavage). We optimized a lateral flow dipstick assay using the galactofuranose -specific monoclonal antibody (mAb476), which was previously shown to recognize urine antigens after Aspergillus fumigatus pulmonary infection in an`imals. Urine samples were obtained from a cohort of 78 subjects undergoing clinical evaluation for suspected invasive fungal infections, and stored frozen until testing. Urine was processed by centrifugation through desalting columns and exposed to dipsticks. Reviewers blinded to EORTC/MSG clinical diagnoses graded results. Western blots were performed on urines from two subjects to characterize mAb476-reactive antigens. Per-patient sensitivity and specificity for diagnosis of proven or probable IA in the overall cohort was 80% (95% CI: 61.4-92.3) and 92% (95% CI 74-99). In the sub-group with cancer, sensitivity was 89.5% (95% CI 66.7-98.7) and specificity was 90.9% (95% CI 58.7 - 99.8); amongst all others, sensitivity and specificity were 63.6 (95% CI 30.8 - 89.1) and 92.9 (66.1 - 99.8), respectively. Eliminating lung transplant recipients with airway disease increased sensitivity in the non-cancer cohort (85.7%, 95% CI 42.1-99.6%). Semi-quantitative urine assay results correlated with serum galactomannan indices. Western blots demonstrated mAb476-reactive antigens in urine from cases, ranging between 26 - 35kDa in size. Urine testing using mAb476 may be used as an aid to diagnose IA in high-risk patients.

  14. Automated biowaste sampling system urine subsystem operating model, part 1

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Rosen, F.

    1973-01-01

    The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.

  15. 10 CFR 26.117 - Preparing urine specimens for storage and shipping.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Preparing urine specimens for storage and shipping. 26.117 Section 26.117 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.117 Preparing urine specimens for storage and shipping. (a) Both the donor and the collector...

  16. 10 CFR 26.117 - Preparing urine specimens for storage and shipping.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Preparing urine specimens for storage and shipping. 26.117 Section 26.117 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.117 Preparing urine specimens for storage and shipping. (a) Both the donor and the collector...

  17. 10 CFR 26.117 - Preparing urine specimens for storage and shipping.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Preparing urine specimens for storage and shipping. 26.117 Section 26.117 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.117 Preparing urine specimens for storage and shipping. (a) Both the donor and the collector...

  18. 10 CFR 26.107 - Collecting a urine specimen.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used for...

  19. 10 CFR 26.107 - Collecting a urine specimen.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used for...

  20. 10 CFR 26.107 - Collecting a urine specimen.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used for...

  1. 10 CFR 26.107 - Collecting a urine specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used for...

  2. 10 CFR 26.107 - Collecting a urine specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used for...

  3. 10 CFR 26.117 - Preparing urine specimens for storage and shipping.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Preparing urine specimens for storage and shipping. 26.117 Section 26.117 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.117 Preparing urine specimens for storage and shipping. (a) Both the donor and the collector...

  4. 10 CFR 26.117 - Preparing urine specimens for storage and shipping.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Preparing urine specimens for storage and shipping. 26.117 Section 26.117 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.117 Preparing urine specimens for storage and shipping. (a) Both the donor and the collector...

  5. 10 CFR 26.111 - Checking the acceptability of the urine specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.111 Checking the acceptability of the urine specimen. (a) Immediately after the donor...

  6. 10 CFR 26.111 - Checking the acceptability of the urine specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.111 Checking the acceptability of the urine specimen. (a) Immediately after the donor...

  7. Effect of vomeronasal organ removal from male mice on their preference for and neural Fos responses to female urinary odors.

    PubMed

    Pankevich, Diana E; Cherry, James A; Baum, Michael J

    2006-08-01

    Four experiments were conducted to determine whether vomeronasal organ (VNO) inputs in male mice mediate the rewarding properties of estrous female urinary odors. Sexually naive male mice with either an intact (VNOi) or lesioned (VNOx) VNO preferred to investigate female urine over water in Y-maze tests. Subsequently, VNOi males ran significantly more quickly and remained in nasal contact longer with estrous female urine than with male urine, whereas VNOx males investigated these odors equally. In home-cage habituation-dishabituation tests, VNOi males also investigated female urine significantly longer than did VNOx males, although both groups investigated female urine longer than other non-body odors. Finally, female urinary odors induced Fos in the nucleus accumbens core of VNOi males but not of VNOx males. Our results suggest that female urinary odors retain some incentive value in VNOx males. However, once direct nasal contact is made with female urine, VNO inputs further activate forebrain mechanisms that amplify the reward salience of this stimulus for the male mouse.

  8. Detection of Leptospiral DNA in the Urine of Donkeys on the Caribbean Island of Saint Kitts

    PubMed Central

    Grevemeyer, Bernard; Vandenplas, Michel; Beigel, Brittney; Cho, Ellen; Willingham, Arve Lee; Verma, Ashutosh

    2017-01-01

    Leptospirosis is a global zoonosis caused by pathogenic spirochetes classified within the genus Leptospira. Leptospires live in the proximal renal tubules of reservoir or chronic carrier animals, and are shed in the urine. Naïve animals acquire infection either when they come in direct contact with a reservoir or infected animals or by exposure to environmental surface water or soil that is contaminated with their urine. In this study, urine samples from a herd of donkeys on the Caribbean island of St. Kitts were screened using a TaqMan-based real-time quantitative polymerase chain reaction (qPCR) targeting a pathogen-specific leptospiral gene, lipl32. Out of 124 clinically normal donkeys, 22 (18%) tested positive for leptospiral DNA in their urine. Water samples from two water troughs used by the donkeys were also tested, but were found to be free from leptospiral contamination. Detection of leptospiral DNA in the urine of clinically healthy donkeys may point to a role that these animals play in the maintenance of the bacteria on St. Kitts. PMID:29056661

  9. Repetitive reddish discoloration of urine in a female adolescent following short-distance walking on a smooth road: Questions.

    PubMed

    Siomou, Ekaterini; Baziou, Maria; Premetis, Evagelos; Vercellati, Cristina; Chaliasos, Nikolaos; Makis, Alexandros

    2017-12-01

    A previously healthy 15-year-old girl was evaluated following five episodes of reddish urine discoloration after walking for approximately 30 min on a smooth roadway. In each episode, the discoloration lasted for four to five urinations and followed by normal urine dipstick tests. No other exercise-produced urine discoloration and no other symptoms were reported. Laboratory evaluation during the episodes revealed a reddish urine sample with 3+ hemoglobin/myoglobin and absence of hematuria. Full blood count, serum creatinine, liver function tests, and electrolyte levels were all within normal limits. Myoglobulinuria was excluded, since muscle enzymes were within normal limits. Blood smear analysis showed mild anisopoikilocytosis with stomatocytes and ovalocytes, leading to extended evaluation for erythrocyte disorders. This case is interesting in that the hemoglobinuria occurred after mild walking and was accompanied by erythrocyte morphological changes. This quiz discusses the differential diagnosis of hemoglobinuria with particular reference to the conditions of appearance (after walking) and emphasizes the importance of step-by-step investigations to reach a definitive diagnosis.

  10. The olfactory hole-board test in rats: a new paradigm to study aversion and preferences to odors

    PubMed Central

    Wernecke, Kerstin E. A.; Fendt, Markus

    2015-01-01

    Odors of biological relevance (e.g., predator odors, sex odors) are known to effectively influence basic survival needs of rodents such as anti-predatory defensiveness and mating behaviors. Research focused on the effects of these odors on rats’ behavior mostly includes multi-trial paradigms where animals experience single odor exposures in subsequent, separated experimental sessions. In the present study, we introduce a modification of the olfactory hole-board test that allows studying the effects of different odors on rats’ behavior within single trials. First, we demonstrated that the corner holes of the hole-board were preferentially visited by rats. The placement of different odors under the corner holes changed this hole preference. We showed that holes with carnivore urine samples were avoided, while corner holes with female rat urine samples were preferred. Furthermore, corner holes with urine samples from a carnivore, herbivore, and omnivore were differentially visited indicating that rats can discriminate these odors. To test whether anxiolytic treatment specifically modulates the avoidance of carnivore urine holes, we treated rats with buspirone. Buspirone treatment completely abolished the avoidance of carnivore urine holes. Taken together, our findings indicate that the olfactory hole-board test is a valuable tool for measuring avoidance and preference responses to biologically relevant odors. PMID:26379516

  11. Evaluation of hematological and biochemical parameters of pesticide retailers following occupational exposure to a mixture of pesticides.

    PubMed

    Neghab, Masoud; Jalilian, Hamed; Taheri, Shekoufeh; Tatar, Mohsen; Haji Zadeh, Zeynab

    2018-06-01

    This study was undertaken to ascertain whether light occupational exposure to pesticides by retailers might be associated with any liver, kidney, nervous system dysfunction or hematological abnormalities. In this cross-sectional study, 70 male pesticide retailers (cases) and 64 male subjects, randomly selected from the constructions workers of city council contractors, as the referent group, were investigated. Urine and blood samples were taken from all subjects for urine analysis, hematological and biochemical parameters. Data analysis was conducted through SPSS v.19 using t-test and chi-square test. The results of urine analysis showed that the frequency of abnormal urine tests was significantly higher in cases than in referent individuals. Similarly, the results of CBC showed that the mean values of monocyte, hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin and platelet distribution width were significantly lower, and mean corpuscular hemoglobin concentration and red blood cell distribution width were significantly higher in retailers. No significant differences were found for other parameters. These findings indicate that an association exists between exposure to pesticides by retailers and early subtle and sub-clinical changes in the urine tests and hematological parameters. Engineering measures are recommended to eliminate exposure to pesticides and to prevent its associated outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. [Effects of aluminum on neurobehavioral function and metabolism of monoamine neurotransmitter].

    PubMed

    Yang, H; Zheng, Y; Liang, Y

    1998-03-01

    To evaluate the effects of occupational exposure to aluminum on neurobahavioral function and metabolism of monoamine neurotransmitter. Thirty-three workers exposed to aluminum and 40 controls were studied. Air aluminum concentrations in workplace environment were detected with an atomic absorption spectrophotometer, homovanillic acid (HVA) and vanilylmandellic acid (VMA) in urine and aluminum in serum and urine were detected with high perfolmance liquid chromatography. Neurobehavioral function was tested with Neurobehavioral Core Test Battery recommended by WHO. Geometric time-weighted average of aluminum in workplace environment was 0.95 mg/m3, ranging from 0.31 to 4.12 mg/m3, and urine aluminum levels in workers exposed to aluminum averaged 12.25 micrograms/L, significantly higher than that in controls (5.78 micrograms/L). There was no significant difference in serum aluminum between the exposed and controls. Both urine VMA and HVA levels were higher in the workers exposed to aluminum, and urine VMA level in the exposed was significantly higher than that in controls. There was significant difference in neurobehavioral test, including Santa Ana, digit symbol and Benton tests between the exposed and control workers. It suggests that occupational exposure to low level of aluminum can affect the neurobehavioral function and metabolism of monoamine neurotransmitter.

  13. Asymptomatic bacteriuria in pregnancy: a diagnostic and therapeutic approach.

    PubMed

    Grio, R; Porpiglia, M; Vetro, E; Uligini, R; Piacentino, R; Minì, D; Marchino, G L

    1994-12-01

    Pregnancy is a predisposing factor for urinary tract infection and pregnant women suffering from this pathology are exposed to dangerous risks which may condition maternal wellbeing and fetal prognosis. The apparently paradoxal finding of a higher incidence of perinatal problems in pregnant women with asymptomatic bacteriuria compared to those with manifest infections may be explained by the fact that the latter are adequately treated, whereas asymptomatic bacteriuria, which is difficult to diagnose, may continue in a subtle form for the entire duration of pregnancy. This emphasises the importance of the early diagnosis of infection using a protocol based on urine tests and urine culture and the adequate treatment of all cases of asymptomatic bacteriuria in order to reduce the incidence of maternal and fetal complications (acute pyelonephritis, increased fetal morbidity and mortality). The choice of the antibiotic to be used must be made on the basis of the urine culture test, the stage of gestation, maternal clinical data and the characteristics of the antibiotic itself (pharmacokinetics, maternal and fetal toxicity). With regard to the treatment protocol, the "single-dose" protocol is currently preferred. After negative urine culture tests, all patients must carry out a complete urine test each month with hormonal and echographic monitoring of the fetoplacental unit.

  14. Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.

    PubMed

    Doyle, Kelly; Strathmann, Frederick G

    2017-02-01

    This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.

  15. Synergism between urinary prothrombin fragment 1 and urine: a comparison of inhibitory activities in stone-prone and stone-free population groups.

    PubMed

    Webber, Dawn; Rodgers, Allen L; Sturrock, Edward D

    2002-09-01

    South African blacks rarely form kidney stones compared with whites. This study investigated whether purified urinary prothrombin fragment 1 (UPTF1) derived from blacks is a more potent inhibitor of calcium oxalate crystallisation than that from whites. UPTF1 was purified from the urine of both population groups and their inhibitory activities were compared in a cross-over design in which each protein was tested in ultrafiltered urine from both population groups. Coulter Multisizer, [14C]-oxalate deposition and scanning electron microscopy experiments were used to monitor crystallisation. The study has demonstrated for the first time that UPTF1 promotes nucleation and that inhibitory activity is synergistically dependent upon urine composition. The activity of the whites' UPTF1 was greater than that of the blacks in the whites' urine (e.g. particle size decrease: 31.7% vs. 25.2%), while the blacks' UPTF1 was superior to that of the whites in the blacks' urine (e.g. particle size decrease: 46.5% vs. 32.4%). In addition, when tested in their respective endogenous urines, the blacks' UPTF1 demonstrated superior inhibitory activity on an absolute scale (e.g. particle size decrease: 46.5% vs. 31.7%). Thus, the urine composition of black South Africans may influence their UPTF1 conformation, conferring greater efficacy for inhibition of calcium oxalate crystallisation.

  16. Paper-Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine.

    PubMed

    Jalal, Uddin M; Jin, Gyeong Jun; Shim, Joon S

    2017-12-19

    In this work, a disposable paper-plastic hybrid microfluidic lab-on-a-chip (LOC) has been developed and successfully applied for the colorimetric measurement of urine by the smartphone-based optical platform using a "UrineAnalysis" Android app. The developed device was cost-effectively implemented as a stand-alone hybrid LOC by incorporating the paper-based conventional reagent test strip inside the plastic-based LOC microchannel. The LOC device quantitatively investigated the small volume (40 μL) of urine analytes for the colorimetric reaction of glucose, protein, pH, and red blood cell (RBC) in integration with the finger-actuating micropump. On the basis of our experiments, the conventional urine strip showed large deviation as the reaction time goes by, because dipping the strip sensor in a bottle of urine could not control the reaction volume. By integrating the strip sensor in the LOC device for urine analysis, our device significantly improves the time-dependent inconstancy of the conventional dipstick-based urine strip, and the smartphone app used for image analysis enhances the visual assessment of the test strip, which is a major user concern for the colorimetric analysis in point-of-care (POC) applications. As a result, the user-friendly LOC, which is successfully implemented in a disposable format with the smartphone-based optical platform, may be applicable as an effective tool for rapid and qualitative POC urinalysis.

  17. Combined quantification of paclitaxel, docetaxel and ritonavir in human feces and urine using LC-MS/MS.

    PubMed

    Hendrikx, Jeroen J M A; Rosing, Hilde; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2014-02-01

    A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human feces and urine is described. The drugs were extracted from 200 μL urine or 50 mg feces followed by high-performance liquid chromatography analysis coupled with positive ionization electrospray tandem mass spectrometry. The validation program included calibration model, accuracy and precision, carry-over, dilution test, specificity and selectivity, matrix effect, recovery and stability. Acceptance criteria were according to US Food and Drug Administration guidelines on bioanalytical method validation. The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel, 2-2000 ng/mL for ritonavir in urine, 2-2000 ng/mg for paclitaxel and docetaxel, and 8-8000 ng/mg for ritonavir in feces. Inter-assay accuracy and precision were tested for all analytes at four concentration levels and were within 8.5% and <10.2%, respectively, in both matrices. Recovery at three concentration levels was between 77 and 94% in feces samples and between 69 and 85% in urine samples. Method development, including feces homogenization and spiking blank urine samples, are discussed. We demonstrated that each of the applied drugs could be quantified successfully in urine and feces using the described assay. The method was successfully applied for quantification of the analytes in feces and urine samples of patients. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Molecular epidemiology and clinical implications of metallo-β-lactamase-producing Pseudomonas aeruginosa isolated from urine.

    PubMed

    Sako, Shinichi; Kariyama, Reiko; Mitsuhata, Ritsuko; Yamamoto, Masumi; Wada, Koichiro; Ishii, Ayano; Uehara, Shinya; Kokeguchi, Susumu; Kusano, Nobuchika; Kumon, Hiromi

    2014-01-01

    We conducted a study on molecular epidemiology and clinical implications of metallo-beta-lactamase (MBL)-producing Pseudomonas aeruginosa isolated from urine. Over a 10-year period from 2001 through 2010, a total of 92 MBL-producing P. aeruginosa urine isolates were collected from patients (one isolate per patient) who were admitted to 5 hospitals in Okayama Prefecture, Japan. When cross-infection was suspected in the hospital, pulsed-field gel electrophoresis was performed. In the resulting dendrogram of 79 MBL-producing P. aeruginosa urine isolates, no identical isolates and 7 pairs of isolates with >80% similarity were found. The biofilm-forming capabilities of 92 MBL-producing P. aeruginosa urine isolates were significantly greater than those of 92 non-MBL-producing urine isolates in a medium of modified artificial urine. The imipenem resistance transferred in 16 of 18 isolates tested, and these frequencies were in the range of 10⁻³ to 10⁻⁹. All of 18 isolates tested belonged to internationally spread sequence type 235 and had 3 gene cassettes of antimicrobial resistance genes in the class 1 integron. The strong biofilm-forming capabilities of MBL-producing P. aeruginosa urine isolates could be seriously implicated in nosocomial infections. To prevent spread of the organism and transferable genes, effective strategies to inhibit biofilm formation in medical settings are needed.

  19. STS-40 Exp. No. 192 urine monitoring system (UMS) on OV-102's middeck

    NASA Image and Video Library

    1991-06-14

    STS040-04-036 (5-14 June 1991) --- Closeup view of urine monitoring system and test samples, part of the busy schedule of life sciences testing on the nine-day STS-40/Spacelab Life Sciences (SLS-1) mission aboard the earth-orbiting Columbia.

  20. Bladder Cancer Symptoms, Tests, Prognosis, and Stages (PDQ®)—Patient Version

    Cancer.gov

    There are three types of bladder cancer. Transitional cell carcinoma, or urothelial carcinoma, is the most common type. Signs of bladder cancer can include blood in the urine and pain during urination. Find out about other symptoms, risk factors, tests to diagnose, and stages of bladder cancer.

  1. Smoking Cessation Failure among Korean Adolescents

    ERIC Educational Resources Information Center

    Kim, Sung Reul; Kim, Hyun Kyung; Kim, Ji Young; Kim, Hye Young; Ko, Sung Hee; Park, Minyoung

    2016-01-01

    The aim of this study was to identify smoking cessation failure subgroups among Korean adolescents. Participants were 379 smoking adolescents who joined a smoking cessation program. A questionnaire and a cotinine urine test were administered before the program began. Three months after the program ended, the cotinine urine test was repeated. A…

  2. Salt as a mitigation option for decreasing nitrogen leaching losses from grazed pastures.

    PubMed

    Ledgard, Stewart F; Welten, Brendon; Betteridge, Keith

    2015-12-01

    The main source of nitrogen (N) leaching from grazed pastures is animal urine with a high N deposition rate (i.e. per urine patch), particularly between late summer and early winter. Salt is a potential mitigation option as a diuretic to induce greater drinking-water intake, increase urination frequency, decrease urine N concentration and urine N deposition rate, and thereby potentially decrease N leaching. This hypothesis was tested in three phases: a cattle metabolism stall study to examine effects of salt supplementation rate on water consumption, urination frequency and urine N concentration; a grazing trial to assess effects of salt (150 g per heifer per day) on urination frequency; and a lysimeter study on effects of urine N rate on N leaching. Salt supplementation increased cattle water intake. Urination frequency increased by up to 69%, with a similar decrease in urine N deposition rate and no change in individual urination volume. Under field grazing, sensors showed increased urination frequency by 17%. Lysimeter studies showed a proportionally greater decrease in N leaching with decreased urine N rate. Modelling revealed that this could decrease per-hectare N leaching by 10-22%. Salt supplementation increases cattle water intake and urination frequency, resulting in a lower urine N deposition rate and proportionally greater decrease in urine N leaching. Strategic salt supplementation in autumn/early winter with feed is a practical mitigation option to decrease N leaching in grazed pastures. © 2015 Society of Chemical Industry.

  3. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis.

    PubMed

    Chaya, Dr; Parija, Subhash Chandra

    2013-07-01

    Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.

  4. A random urine test can identify patients at risk of mesalamine non-adherence: a prospective study.

    PubMed

    Gifford, Anne E; Berg, Anders H; Lahiff, Conor; Cheifetz, Adam S; Horowitz, Gary; Moss, Alan C

    2013-02-01

    Mesalamine non-adherence is common among patients with ulcerative colitis (UC), and can be difficult to identify in practice. We sought to determine whether a random urine test for salicylates could be used as a marker of 5-aminosalicylic acid (5-ASA) ingestion and identify patients at risk of non-adherence. Our aim is to determine whether measurement of salicylates in a random urine sample correlates with 5-ASA levels, and predicts an individual's risk of mesalamine non-adherence. Prospective observational study. Urinary salicylates (by colorimetry) and 5-ASA (by liquid chromatography and tandem-mass spectrometry) were measured in a random urine sample at baseline in patients and controls. Mesalamine adherence was quantified by patient self-reports at enrollment and pharmacy refills of mesalamine over 6 months. A total of 93 patients with UC taking mesalamine maintenance therapy were prospectively enrolled from the clinic. Random urine salicylate levels (by colorimetry) were highly correlated with urine 5-ASA metabolite levels (by mass spectrometry; R2=0.9). A random urine salicylate level above 15 mg/dl distinguished patients who had recently taken mesalamine from controls (area under the curve value 0.9, sensitivity 95%, specificity 77%). A significant proportion of patients (27%) who self-identified as "high adherers" by an adherence questionnaire (Morisky Medication Adherence Scale-8) had random levels of urine salicylate below this threshold. These patients were at higher risk of objectively measured non-adherence to mesalamine over the subsequent 6 months (RR: 2.7, 95% CI: 1.1-7.0). A random urine salicylate level measured in the clinic can identify patients who have not recently taken mesalamine, and who are at higher risk of longitudinal non-adherence. This test could be used to screen patients who may warrant interventions to improve adherence and prevent disease relapse.

  5. Prostatectomy-based validation of combined urine and plasma test for predicting high grade prostate cancer.

    PubMed

    Albitar, Maher; Ma, Wanlong; Lund, Lars; Shahbaba, Babak; Uchio, Edward; Feddersen, Søren; Moylan, Donald; Wojno, Kirk; Shore, Neal

    2018-03-01

    Distinguishing between low- and high-grade prostate cancers (PCa) is important, but biopsy may underestimate the actual grade of cancer. We have previously shown that urine/plasma-based prostate-specific biomarkers can predict high grade PCa. Our objective was to determine the accuracy of a test using cell-free RNA levels of biomarkers in predicting prostatectomy results. This multicenter community-based prospective study was conducted using urine/blood samples collected from 306 patients. All recruited patients were treatment-naïve, without metastases, and had been biopsied, designated a Gleason Score (GS) based on biopsy, and assigned to prostatectomy prior to participation in the study. The primary outcome measure was the urine/plasma test accuracy in predicting high grade PCa on prostatectomy compared with biopsy findings. Sensitivity and specificity were calculated using standard formulas, while comparisons between groups were performed using the Wilcoxon Rank Sum, Kruskal-Wallis, Chi-Square, and Fisher's exact test. GS as assigned by standard 10-12 core biopsies was 3 + 3 in 90 (29.4%), 3 + 4 in 122 (39.8%), 4 + 3 in 50 (16.3%), and > 4 + 3 in 44 (14.4%) patients. The urine/plasma assay confirmed a previous validation and was highly accurate in predicting the presence of high-grade PCa (Gleason ≥3 + 4) with sensitivity between 88% and 95% as verified by prostatectomy findings. GS was upgraded after prostatectomy in 27% of patients and downgraded in 12% of patients. This plasma/urine biomarker test accurately predicts high grade cancer as determined by prostatectomy with a sensitivity at 92-97%, while the sensitivity of core biopsies was 78%. © 2018 Wiley Periodicals, Inc.

  6. Clinical accuracy of point-of-care urine culture in general practice.

    PubMed

    Holm, Anne; Cordoba, Gloria; Sørensen, Tina Møller; Jessen, Lisbeth Rem; Frimodt-Møller, Niels; Siersma, Volkert; Bjerrum, Lars

    2017-06-01

    To assess the clinical accuracy (sensitivity (SEN), specificity (SPE), positive predictive value and negative predictive value) of two point-of-care (POC) urine culture tests for the identification of urinary tract infection (UTI) in general practice. Prospective diagnostic accuracy study comparing two index tests (Flexicult™ SSI-Urinary Kit or ID Flexicult™) with a reference standard (urine culture performed in the microbiological department). General practice in the Copenhagen area patients. Adult female patients consulting their general practitioner with suspected uncomplicated, symptomatic UTI. (1) Overall accuracy of POC urine culture in general practice. (2) Individual accuracy of each of the two POC tests in this study. (3) Accuracy of POC urine culture in general practice with enterococci excluded, since enterococci are known to multiply in boric acid used for transportation for the reference standard. (4) Accuracy based on expert reading of photographs of POC urine cultures performed in general practice. Standard culture performed in the microbiological department was used as reference standard for all four measures. Twenty general practices recruited 341 patients with suspected uncomplicated UTI. The overall agreement between index test and reference was 0.76 (CI: 0.71-0.80), SEN 0.88 (CI: 0.83-0.92) and SPE 0.55 (CI: 0.46-0.64). The two POC tests produced similar results individually. Overall agreement with enterococci excluded was 0.82 (0.77-0.86) and agreement between expert readings of photographs and reference results was 0.81 (CI: 0.76-0.85). POC culture used in general practice has high SEN but low SPE. Low SPE could be due to both misinterpretation in general practice and an imperfect reference standard. Registration number: ClinicalTrials.gov NCT02323087.

  7. Interlaboratory and between-specimen comparisons of diagnostic tests for leptospirosis in sheep and cattle.

    PubMed

    Fang, Fang; Collins-Emerson, Julie M; Heuer, Cord; Hill, Fraser I; Tisdall, David J; Wilson, Peter R; Benschop, Jackie

    2014-11-01

    A study was performed to investigate interlaboratory test agreement between a research and a commercial veterinary diagnostic laboratory on blood and urine samples, and to investigate test agreement between blood, urine, and kidney samples (research laboratory) for leptospirosis diagnosis. Samples were sourced from 399 sheep and 146 beef cattle from a local abattoir. Interlaboratory agreement for real-time quantitative polymerase chain reaction (qPCR) results on urine samples was almost perfect (kappa = 0.90), despite the use of different amplification targets (DNA gyrase subunit B gene vs. 16s ribosomal RNA gene), chemistries (SYTO9 vs. TaqMan probe), and pre-PCR processing. Interlaboratory agreement for microscopic agglutination test (MAT) positivity was almost perfect (kappa = 0.93) for Leptospira borgpetersenii serovar Hardjo subtype Hardjobovis (Hardjobovis) but moderate (kappa = 0.53) for Leptospira interrogans serovar Pomona (Pomona). Among animals that had different titers recorded, higher Hardjobovis and lower Pomona titers were reported by the commercial laboratory than by the research laboratory (P < 0.005). These interlaboratory comparisons can assist researchers and diagnosticians in interpreting the sometimes discrepant test results. Within the research laboratory, the comparison of qPCR results on urine and kidney showed almost perfect agreement (kappa = 0.84), suggesting that the qPCR on these 2 specimens can be used interchangeably. The agreement between MAT positivity and urine and kidney qPCR results was fair (kappa = 0.32 and kappa = 0.33, respectively). However, the prevalence ratio of urine and kidney qPCR positivity in Hardjobovis-seropositive versus Hardjobovis-seronegative sheep indicated that Hardjobovis seropositivity found in sheep may be able to predict shedding or renal carriage. © 2014 The Author(s).

  8. Effects of diet composition on mutagenic activity in urine.

    PubMed

    Ohara, Akihiro; Matsuhisa, Tsugio

    2004-01-01

    The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.

  9. Retrograde contamination and practical handling of urine-meters: a comparison of three systems for the measurement of hourly diuresis in an experimental bladder-drainage model and in clinical use.

    PubMed

    Rasmussen, A; Frimodt-Møller, N; Espersen, F; Roed, M; Frimodt-Møller, C

    1996-08-01

    To compare three different urine metering systems for their ability to prevent retrograde contamination in an in vitro model of a closed urinary drainage system and for qualities important to their practical handling in a clinical setting. Using three urine-meters (the Braun Ureofix 511, the Kendall Curity 4000 and the Unoplast Unometer 500) the in vitro model was constantly flushed with a solution of Mueller-Hinton broth diluted with saline. On the first day, the urine collecting bag was inoculated with 10(8) cells of Pseudomonas aeruginosa. The system was operated for 12 days with daily sampling of the model bladder to detect any contamination. After 12 days the experiment was stopped and sampling performed at various locations, including the urine-meter and the tubing. Nine of each type of urine-meter were tested, i.e. three in three different experiments. In the clinical study, 45 patients were randomized to each of the three urine-meters and the nurses attending them were asked to complete a questionnaire on the practical handling of the urine-meters. When the urine-meters was omitted from the model system, the 'bladder' became contaminated with the test bacteria within 3 days. None of the nine Unometer 500 systems became contaminated, compared with four of each of the other two systems (P < 0.05). In clinical use, the Unometer 500 and Ureofix 511 were easier to suspend and empty than was the Curity 4000. The Unometer 500 was significantly easier to handle when the collecting bag was emptied. Urine-meters can prevent retrograde contamination in a closed bladder-drainage model, but the degree of prevention depends upon the type of urine-meter. In daily practice, there were differences in the ease of suspension of the systems and in the emptying of the urine-meter and collecting bag.

  10. Regulation of glucose and ketone-body metabolism in brain of anaesthetized rats

    PubMed Central

    Ruderman, Neil B.; Ross, Peter S.; Berger, Michael; Goodman, Michael N.

    1974-01-01

    1. The effects of starvation and diabetes on brain fuel metabolism were examined by measuring arteriovenous differences for glucose, lactate, acetoacetate and 3-hydroxybutyrate across the brains of anaesthetized fed, starved and diabetic rats. 2. In fed animals glucose represented the sole oxidative fuel of the brain. 3. After 48h of starvation, ketone-body concentrations were about 2mm and ketone-body uptake accounted for 25% of the calculated O2 consumption: the arteriovenous difference for glucose was not diminished, but lactate release was increased, suggesting inhibition of pyruvate oxidation. 4. In severe diabetic ketosis, induced by either streptozotocin or phlorrhizin (total blood ketone bodies >7mm), the uptake of ketone bodies was further increased and accounted for 45% of the brain's oxidative metabolism, and the arteriovenous difference for glucose was decreased by one-third. The arteriovenous difference for lactate was increased significantly in the phlorrhizin-treated rats. 5. Infusion of 3-hydroxybutyrate into starved rats caused marked increases in the arteriovenous differences for lactate and both ketone bodies. 6. To study the mechanisms of these changes, steady-state concentrations of intermediates and co-factors of the glycolytic pathway were determined in freeze-blown brain. 7. Starved rats had increased concentrations of acetyl-CoA. 8. Rats with diabetic ketosis had increased concentrations of fructose 6-phosphate and decreased concentrations of fructose 1,6-diphosphate, indicating an inhibition of phosphofructokinase. 9. The concentrations of acetyl-CoA, glycogen and citrate, a potent inhibitor of phosphofructokinase, were increased in the streptozotocin-treated rats. 10. The data suggest that cerebral glucose uptake is decreased in diabetic ketoacidosis owing to inhibition of phosphofructokinase as a result of the increase in brain citrate. 11. The inhibition of brain pyruvate oxidation in starvation and diabetes can be related to the accelerated rate of ketone-body metabolism; however, we found no correlation between the decrease in glucose uptake in the diabetic state and the arteriovenous difference for ketone bodies. 12. The data also suggest that the rates of acetoacetate and 3-hydroxybutyrate utilization by brain are governed by their concentrations in plasma. 13. The finding of very low concentrations of acetoacetate and 3-hydroxybutyrate in brain compared with plasma suggests that diffusion across the blood–brain barrier may be the rate-limiting step in their metabolism. PMID:4275704

  11. Prevalence and spot urine risk factors for renal stones in children taking topiramate.

    PubMed

    Corbin Bush, Nicol; Twombley, Katherine; Ahn, Justin; Oliveira, Carlos; Arnold, Susan; Maalouf, Naim M; Sakhaee, Khashayar

    2013-12-01

    Topiramate (TPM), an anti-epileptic drug with >4 million users, increases renal stones in adults. We screened outpatient TPM-treated children without history of stones to estimate the prevalence of renal stones and to characterize urine stone-risk profiles. Children taking TPM ≥1 month underwent an interview, renal ultrasound, and spot urine testing in this prospective study. Normal spot urine values were defined as: calcium/creatinine ratio ≤0.20 mg/mg (>12 months) or ≤0.60 mg/mg (≤12 months), citrate/creatinine ratio >0.50 mg/mg, and pH ≤ 6.7. Of 41 patients with average age of 9.2 years (range 0.5-18.7), mean TPM dose of 8.0 mg/kg/day (range 1.4-23.6), and mean treatment duration of 27 months (range 1-112), two (4.9%) had renal stones. The majority of children taking TPM had lithogenic abnormalities on spot urine testing, including 21 (51%) with hypercalciuria, 38 (93%) with hypocitraturia, and 28 (68%) with pH ≥ 6.7. Hypercalciuria and hypocitraturia were independent of TPM dose and duration; urine pH increased with dose. 24-h urine parameters improved in 1 stone-former once TPM was weaned. Asymptomatic stones were found in 2/41 (4.8%) children taking TPM. Risk factors for stones were present in the spot urine of most children, including hypocitraturia (93%) and hypercalciuria (51%), independent of TPM dose and duration. High urine pH, found in 68%, correlated with TPM dose. Pediatric specialists should be aware of increased risks for stones, hypercalciuria, hypocitraturia, and alkaline urine in children taking TPM. Published by Elsevier Ltd.

  12. Urine Culture on Admission Impacts Antibiotic Use and Length of Stay: A Retrospective Cohort Study.

    PubMed

    Horstman, Molly J; Spiegelman, Andrew M; Naik, Aanand D; Trautner, Barbara W

    2018-05-01

    OBJECTIVETo examine the impact of urine culture testing on day 1 of admission on inpatient antibiotic use and hospital length of stay (LOS).DESIGNWe performed a retrospective cohort study using a national dataset from 2009 to 2014.SETTINGThe study used data from 230 hospitals in the United States.PARTICIPANTSAdmissions for adults 18 years and older were included in this study. Hospitalizations were matched with coarsened exact matching by facility, patient age, gender, Medicare severity-diagnosis related group (MS-DRG), and 3 measures of disease severity.METHODSA multilevel Poisson model and a multilevel linear regression model were used to determine the impact of an admission urine culture on inpatient antibiotic use and LOS.RESULTSMatching produced a cohort of 88,481 patients (n=41,070 with a culture on day 1, n=47,411 without a culture). A urine culture on admission led to an increase in days of inpatient antibiotic use (incidence rate ratio, 1.26; P<.001) and resulted in an additional 36,607 days of inpatient antibiotic treatment. Urine culture on admission resulted in a 2.1% increase in LOS (P=.004). The predicted difference in bed days of care between admissions with and without a urine culture resulted in 6,071 additional bed days of care. The impact of urine culture testing varied by admitting diagnosis.CONCLUSIONSPatients with a urine culture sent on day 1 of hospital admission receive more days of antibiotics and have a longer hospital stay than patients who do not have a urine culture. Targeted interventions may reduce the potential harms associated with low-yield urine cultures on day 1.Infect Control Hosp Epidemiol 2018;39:547-554.

  13. Simple questionnaire and urine reagent strips compared to microscopy for the diagnosis of Schistosoma haematobium in a community in northern Ghana.

    PubMed

    Bogoch, Isaac I; Andrews, Jason R; Dadzie Ephraim, Richard K; Utzinger, Jürg

    2012-10-01

    To evaluate the utility of a simple questionnaire and urine reagent strip testing for the rapid diagnosis of Schistosoma haematobium in rural northern Ghana. Cross-sectional parasitological and questionnaire survey in a community in northern Ghana. Participants provided two urine specimens that were examined under a microscope using a centrifugation method. The first urine sample was additionally subjected to reagent strip testing. A short questionnaire was administered to all participants. Microscopy of urine samples obtained from 208 individuals aged 1-77 years revealed an S. haematobium prevalence of 6.8%. The presence of any blood or protein on a urine reagent strip was 100% and 42% sensitive, and 93% and 80% specific for S. haematobium diagnosis. Questionnaires were completed by 198 individuals. Self-reported haematuria showed a sensitivity of 53% and a specificity of 85%. A dichotomous two-question panel was helpful in S. haematobium diagnosis, with working and playing near the river significantly associated with S. haematobium infection (P < 0.001). The use of urine reagent strips, coupled with questions pertaining to water contact patterns, might be considered for point-of-contact diagnosis of S. haematobium where microscopy is unavailable. © 2012 Blackwell Publishing Ltd.

  14. Improving the Diagnosis of Legionella Pneumonia within a Healthcare System through a Systematic Consultation and Testing Program.

    PubMed

    Decker, Brooke K; Harris, Patricia L; Muder, Robert R; Hong, Jae H; Singh, Nina; Sonel, Ali F; Clancy, Cornelius J

    2016-08-01

    Legionella testing is not recommended for all patients with pneumonia, but rather for particular patient subgroups. As a result, the overall incidence of Legionella pneumonia may be underestimated. To determine the incidence of Legionella pneumonia in a veteran population in an endemic area after introduction of a systematic infectious diseases consultation and testing program. In response to a 2011-2012 outbreak, the VA Pittsburgh Healthcare System mandated infectious diseases consultations and testing for Legionella by urine antigen and sputum culture in all patients with pneumonia. Between January 2013 and December 2015, 1,579 cases of pneumonia were identified. The incidence of pneumonia was 788/100,000 veterans per year, including 352/100,000 veterans per year and 436/100,000 veterans per year with community-associated pneumonia (CAP) and health care-associated pneumonia, respectively. Ninety-eight percent of patients with suspected pneumonia were tested for Legionella by at least one method. Legionella accounted for 1% of pneumonia cases (n = 16), including 1.7% (12/706) and 0.6% (4/873) of CAP and health care-associated pneumonia, respectively. The yearly incidences of Legionella pneumonia and Legionella CAP were 7.99 and 5.99/100,000 veterans, respectively. The sensitivities of urine antigen and sputum culture were 81% and 60%, respectively; the specificity of urine antigen was >99.97%. Urine antigen testing and Legionella cultures increased by 65% and 330%, respectively, after introduction of our program. Systematic testing of veterans in an endemic area revealed a higher incidence of Legionella pneumonia and CAP than previously reported. Widespread urine antigen testing was not limited by false positivity.

  15. Urine analysis concerning xenon for doping control purposes.

    PubMed

    Thevis, Mario; Piper, Thomas; Geyer, Hans; Schaefer, Maximilian S; Schneemann, Julia; Kienbaum, Peter; Schänzer, Wilhelm

    2015-01-15

    On September 1(st) 2014, a modified Prohibited List as established by the World Anti-Doping Agency (WADA) became effective featuring xenon as a banned substance categorized as hypoxia-inducible factor (HIF) activator. Consequently, the analysis of xenon from commonly provided doping control specimens such as blood and urine is desirable, and first data on the determination of xenon from urine in the context of human sports drug testing, are presented. In accordance to earlier studies utilizing plasma as doping control matrix, urine was enriched to saturation with xenon, sequentially diluted, and the target analyte was detected as supported by the internal standard d6 -cyclohexanone by means of gas chromatography/triple quadrupole mass spectrometry (GC/MS/MS) using headspace injection. Three major xenon isotopes at m/z 128.9, 130.9 and 131.9 were targeted in (pseudo) selected reaction monitoring mode enabling the unambiguous identification of the prohibited substance. Assay characteristics including limit of detection (LOD), intraday/interday precision, and specificity as well as analyte recovery under different storage conditions were determined. Proof-of-concept data were generated by applying the established method to urine samples collected from five patients before, during and after (up to 48 h) xenon-based general anesthesia. Xenon was traceable in enriched human urine samples down to the detection limit of approximately 0.5 nmol/mL. The intraday and interday imprecision values of the method were found below 25%, and specificity was demonstrated by analyzing 20 different blank urine samples that corroborated the fitness-for-purpose of the analytical approach to unequivocally detect xenon at non-physiological concentrations in human urine. The patients' urine specimens returned 'xenon-positive' test results up to 40 h post-anesthesia, indicating the limits of the expected doping control detection window. Since xenon has been considered a prohibited substance according to WADA regulations in September 2014, its analysis from common specimens of routine sports drug testing is desirable. In previous studies, its traceability in whole blood and plasma was shown, and herein a complementary approach utilizing doping control urine samples for the GC/MS/MS analysis of xenon was reported. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Rapid microbiological screening for tuberculosis in HIV-positive patients on the first day of acute hospital admission by systematic testing of urine samples using Xpert MTB/RIF: a prospective cohort in South Africa.

    PubMed

    Lawn, Stephen D; Kerkhoff, Andrew D; Burton, Rosie; Schutz, Charlotte; van Wyk, Gavin; Vogt, Monica; Pahlana, Pearl; Nicol, Mark P; Meintjes, Graeme

    2015-08-14

    Autopsy studies of HIV/AIDS-related hospital deaths in sub-Saharan Africa reveal frequent failure of pre-mortem diagnosis of tuberculosis (TB), which is found in 34-64 % of adult cadavers. We determined the overall prevalence and predictors of TB among consecutive unselected HIV-positive adults requiring acute hospital admission and the comparative diagnostic yield obtained by screening urine and sputum samples obtained on day 1 of admission with Xpert MTB/RIF (Xpert). To determine overall TB prevalence accurately, comprehensive clinical sampling (sputum, urine, blood plus other relevant samples) was done and TB was defined by detection of Mycobacterium tuberculosis in any sample using Xpert and/or mycobacterial liquid culture. To evaluate a rapid screening strategy, we compared the diagnostic yield of Xpert testing sputum samples and urine samples obtained with assistance from a respiratory study nurse in the first 24 h of admission. Unselected HIV-positive acute adult new medical admissions (n = 427) who were not receiving TB treatment were enrolled irrespective of clinical presentation or symptom profile. From 2,391 cultures and Xpert tests done (mean, 5.6 tests/patient) on 1,745 samples (mean, 4.1 samples/patient), TB was diagnosed in 139 patients (median CD4 cell count, 80 cells/μL). TB prevalence was very high (32.6 %; 95 % CI, 28.1-37.2 %; 139/427). However, patient symptoms and risk factors were poorly predictive for TB. Overall, ≥1 non-respiratory sample(s) tested positive in 115/139 (83 %) of all TB cases, including positive blood cultures in 41/139 (29.5 %) of TB cases. In the first 24 h of admission, sputum (spot and/or induced samples) and urine were obtainable from 37.0 % and 99.5 % of patients, respectively (P <0.001). From these, the proportions of total TB cases (n = 139) that were diagnosed by Xpert testing sputum, urine or both sputum and urine combined within the first 24 h were 39/139 (28.1 %), 89/139 (64.0 %) and 108/139 (77.7 %) cases, respectively (P <0.001). The very high prevalence of active TB and its non-specific presentation strongly suggest the need for routine microbiological screening for TB in all HIV-positive medical admissions in high-burden settings. The incremental diagnostic yield from Xpert testing urine was very high and this strategy might be used to rapidly screen new admissions, especially if sputum is difficult to obtain.

  17. Integrated water management system - Description and test results. [for Space Station waste water processing

    NASA Technical Reports Server (NTRS)

    Elden, N. C.; Winkler, H. E.; Price, D. F.; Reysa, R. P.

    1983-01-01

    Water recovery subsystems are being tested at the NASA Lyndon B. Johnson Space Center for Space Station use to process waste water generated from urine and wash water collection facilities. These subsystems are being integrated into a water management system that will incorporate wash water and urine processing through the use of hyperfiltration and vapor compression distillation subsystems. Other hardware in the water management system includes a whole body shower, a clothes washing facility, a urine collection and pretreatment unit, a recovered water post-treatment system, and a water quality monitor. This paper describes the integrated test configuration, pertinent performance data, and feasibility and design compatibility conclusions of the integrated water management system.

  18. Urine protein electrophoresis test

    MedlinePlus

    Urine protein electrophoresis; UPEP; Multiple myeloma - UPEP; Waldenström macroglobulinemia - UPEP; Amyloidosis - UPEP ... special paper and apply an electric current. The proteins move and form visible bands. These reveal the ...

  19. Urinalysis

    MedlinePlus

    ... urine To diagnose a urinary tract infection Normal Results Normal urine varies in color from almost colorless ... meaning of your specific test results. What Abnormal Results Mean Abnormal results may mean you have an ...

  20. Baby care product development: artificial urine in vitro assay is useful for cosmetic product assessment.

    PubMed

    Degouy, Arnaud; Gomez-Berrada, Marie-Pierre; Ferret, Pierre-Jacques

    2014-02-01

    As a result of infants' inability to control urination, the skin of the diaper area has special needs for protection from irritating effects of urine and prevention of diaper dermatitis such as products for cleansing and protection of the skin. Several in vitro models are currently available to assess tolerance. In vitro testing using artificial urine allows the protective effects of diaper-region cosmetics to be ascertained. Thus, a new model defined as "artificial urine in vitro assay" has been added to our traditional pre-clinical in vitro testing program. IL1-α is a highly active and pleiotropic pro-inflammatory cytokine. It plays a key role in inflammation and is the biological mirror of irritation induced by diaper dermatitis. This study determines, on human skin explants, if a cosmetic formula is (1) tolerated equally as well in the presence of artificial urine as in its absence and (2) is able to decrease IL1-α production induced by artificial urine or Sodium Dodecyl Sulfate. 31 tests including 17 in-house formulas, 10 bench-markers and 4 combinations of products were performed and data obtained are represented on a simple four-point scale (from practically non protective to very protective). It allows determination of formula-type groups that will have predictable protective properties in subsequent clinical trials and comparison with competitors' products. It is a useful aid in the formulation stage and provides readily-useable data for the cosmetic risk assessment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Doping control container for urine stabilization: a pilot study.

    PubMed

    Tsivou, Maria; Giannadaki, Evangelia; Hooghe, Fiona; Roels, Kris; Van Gansbeke, Wim; Garribba, Flaminia; Lyris, Emmanouil; Deventer, Koen; Mazzarino, Monica; Donati, Francesco; Georgakopoulos, Dimitrios G; Van Eenoo, Peter; Georgakopoulos, Costas G; de la Torre, Xavier; Botrè, Francesco

    2017-05-01

    Urine collection containers used in the doping control collection procedure do not provide a protective environment for urine, against degradation by microorganisms and proteolytic enzymes. An in-house chemical stabilization mixture was developed to tackle urine degradation problems encountered in human sport samples, in cases of microbial contamination or proteolytic activity. The mixture consists of antimicrobial substances and protease inhibitors for the simultaneous inactivation of a wide range of proteolytic enzymes. It has already been tested in lab-scale, as part of World Anti-Doping Agency's (WADA) funded research project, in terms of efficiency against microbial and proteolytic activity. The present work, funded also by WADA, is a follow-up study on the improvement of chemical stabilization mixture composition, application mode and limitation of interferences, using pilot urine collection containers, spray-coated in their internal surface with the chemical stabilization mixture. Urine in plastic stabilized collection containers have been gone through various incubation cycles to test for stabilization efficiency and analytical matrix interferences by three WADA accredited Laboratories (Athens, Ghent, and Rome). The spray-coated chemical stabilization mixture was tested against microorganism elimination and steroid glucuronide degradation, as well as enzymatic breakdown of proteins, such as intact hCG, recombinant erythropoietin and small peptides (GHRPs, ipamorelin), induced by proteolytic enzymes. Potential analytical interferences, observed in the presence of spray-coated chemical stabilization mixture, were recorded using routine screening procedures. The results of the current study support the application of the spray-coated plastic urine container, in the doping control collection procedure. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. 49 CFR 40.71 - How does the collector prepare the specimens?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.71 How does the... brings the urine specimen to you. You must take these steps in the presence of the employee. (1) Check... employee, must first pour at least 30 mL of urine from the collection container into one specimen bottle...

  3. 49 CFR 40.71 - How does the collector prepare the specimens?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.71 How does the... brings the urine specimen to you. You must take these steps in the presence of the employee. (1) Check... employee, must first pour at least 30 mL of urine from the collection container into one specimen bottle...

  4. 49 CFR 40.71 - How does the collector prepare the specimens?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.71 How does the... brings the urine specimen to you. You must take these steps in the presence of the employee. (1) Check... employee, must first pour at least 30 mL of urine from the collection container into one specimen bottle...

  5. 49 CFR 40.71 - How does the collector prepare the specimens?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.71 How does the... brings the urine specimen to you. You must take these steps in the presence of the employee. (1) Check... employee, must first pour at least 30 mL of urine from the collection container into one specimen bottle...

  6. 49 CFR 40.71 - How does the collector prepare the specimens?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.71 How does the... brings the urine specimen to you. You must take these steps in the presence of the employee. (1) Check... employee, must first pour at least 30 mL of urine from the collection container into one specimen bottle...

  7. Diagnostic accuracy of self-administered urine glucose test strips as a diabetes screening tool in a low-resource setting in Cambodia.

    PubMed

    Storey, Helen L; van Pelt, Maurits H; Bun, Socheath; Daily, Frances; Neogi, Tina; Thompson, Matthew; McGuire, Helen; Weigl, Bernhard H

    2018-03-22

    Screening for diabetes in low-resource countries is a growing challenge, necessitating tests that are resource and context appropriate. The aim of this study was to determine the diagnostic accuracy of a self-administered urine glucose test strip compared with alternative diabetes screening tools in a low-resource setting of Cambodia. Prospective cross-sectional study. Members of the Borey Santepheap Community in Cambodia (Phnom Penh Municipality, District Dangkao, Commune Chom Chao). All households on randomly selected streets were invited to participate, and adults at least 18 years of age living in the study area were eligible for inclusion. The accuracy of self-administered urine glucose test strip positivity, Hemoglobin A1c (HbA1c)>6.5% and capillary fasting blood glucose (cFBG) measurement ≥126 mg/dL were assessed against a composite reference standard of cFBGmeasurement ≥200 mg/dL or venous blood glucose 2 hours after oral glucose tolerance test (OGTT) ≥200 mg/dL. Of the 1289 participants, 234 (18%) had diabetes based on either cFBG measurement (74, 32%) or the OGTT (160, 68%). The urine glucose test strip was 14% sensitive and 99% specific and failed to identify 201 individuals with diabetes while falsely identifying 7 without diabetes. Those missed by the urine glucose test strip had lower venous fasting blood glucose, lower venous blood glucose 2 hours after OGTT and lower HbA1c compared with those correctly diagnosed. Low cost, easy to use diabetes tools are essential for low-resource communities with minimal infrastructure. While the urine glucose test strip may identify persons with diabetes that might otherwise go undiagnosed in these settings, its poor sensitivity cannot be ignored. The massive burden of diabetes in low-resource settings demands improvements in test technologies. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Urine toxicology screening in an urban stroke and TIA population.

    PubMed

    Silver, Brian; Miller, Daniel; Jankowski, Michelle; Murshed, Nawaf; Garcia, Patricia; Penstone, Patricia; Straub, Melissa; Logan, Sean P; Sinha, Anita; Morris, Daniel C; Katramados, Angelos; Russman, Andrew N; Mitsias, Panayiotis D; Schultz, Lonni R

    2013-04-30

    We sought to determine the rate of urine toxicology screening, differences in testing, and outcomes among patients with stroke and TIA presenting to a tertiary care emergency department. In this retrospective cohort study, patients admitted with stroke or TIA to a single tertiary care stroke center between June 2005 and January 2007 were identified through a stroke database. Factors that predicted urine toxicology screening of patients and a positive test, and discharge outcomes of patients based on toxicology result were analyzed. Stroke severity, treatment with tissue plasminogen activator, discharge status, and stroke etiology were compared between toxicology positive and negative patients. A total of 1,024 patients were identified: 704 with ischemic stroke, 133 with intracerebral hemorrhage, and 205 with TIA. Urine toxicology screening was performed in 420 patients (40%); 11% of these studies were positive for cocaine (19% younger than 50 years and 9% 50 years or older). Factors that significantly predicted the performance of a urine toxicology screen were younger age (<50 years) and black race (<0.001). Positive toxicology screens occurred in a broad range of patients. There were no significant differences in admission NIH Stroke Scale score, stroke etiology, and discharge status between toxicology-positive and -negative patients. In this study, patients with stroke and TIA who were young and black were more likely to have urine toxicology screening. Eleven percent of all tested patients (and 9% of patients 50 years or older) were positive for cocaine. To avoid disparities, we suggest that all stroke and TIA patients be tested.

  9. Grapefruit Derived Flavonoid Naringin Improves Ketoacidosis and Lipid Peroxidation in Type 1 Diabetes Rat Model.

    PubMed

    Murunga, Alfred N; Miruka, David O; Driver, Christine; Nkomo, Fezile S; Cobongela, Snazo Z Z; Owira, Peter M O

    2016-01-01

    Hypoglycemic effects of grapefruit juice are well known but the effects of naringin, its main flavonoid on glucose intolerance and metabolic complications in type 1 diabetes are not known. To investigate the effects of naringin on glucose intolerance, oxidative stress and ketonemia in type 1 diabetic rats. Sprague-Dawley rats divided into 5 groups (n = 7) were orally treated daily with 3.0 ml/kg body weight (BW)/day of distilled water (group 1) or 50 mg/kg BW of naringin (groups 2 and 4, respectively). Groups 3, 4 and 5 were given a single intra-peritoneal injection of 60 mg/kg BW of streptozotocin to induce diabetes. Group 3 was further treated with subcutaneous insulin (4.0 IU/kg BW) twice daily, respectively. Stretozotocin (STZ) only-treated groups exhibited hyperglycemia, polydipsia, polyuria, weight loss, glucose intolerance, low fasting plasma insulin and reduced hepatic glycogen content compared to the control group. Furthermore they had significantly elevated Malondialdehyde (MDA), acetoacetate, β-hydroxybutyrate, anion gap and significantly reduced blood pH and plasma bicarbonate compared to the control group. Naringin treatment significantly improved Fasting Plasma Insulin (FPI), hepatic glycogen content, malondialdehyde, β-hydroxybutyrate, acetoacetate, bicarbonate, blood pH and anion gap but not Fasting Blood Glucose (FBG) compared to the STZ only-treated group. Naringin is not hypoglycemic but ameliorates ketoacidosis and oxidative stress. Naringin supplements could therefore mitigate complications of diabetic ketoacidosis.

  10. Mangiferin supplementation improves serum lipid profiles in overweight patients with hyperlipidemia: a double-blind randomized controlled trial.

    PubMed

    Na, Lixin; Zhang, Qiao; Jiang, Shuo; Du, Shanshan; Zhang, Wei; Li, Ying; Sun, Changhao; Niu, Yucun

    2015-05-19

    Our previous studies have shown that mangiferin decreased serum triglycerides and free fatty acids (FFAs) by increasing FFAs oxidation in both animal and cell experiments. This study sought to evaluate the effects of mangiferin on serum lipid profiles in overweight patients with hyperlipidemia. Overweight patients with hyperlipidemia (serum triglyceride ≥ 1.70 mmol/L, and total cholesterol ≥ 5.2 mmol/L) were included in this double-blind randomized controlled trial. Participants were randomly allocated to groups, either receiving mangiferin (150 mg/day) or identical placebo for 12 weeks. The lipid profile and serum levels of mangiferin, glucose, L-carnitine, β-hydroxybutyrate, and acetoacetate were determined at baseline and 12 weeks. A total of 97 participants completed the trial. Compared with the placebo control, mangiferin supplementation significantly decreased the serum levels of triglycerides and FFAs, and insulin resistance index. Mangiferin supplementation also significantly increased the serum levels of mangiferin, high-density lipoprotein cholesterol, L-carnitine, β-hydroxybutyrate, and acetoacetate, and increased lipoprotein lipase activity. However, there were no differences in the serum levels of total cholesterol, low-density lipoprotein cholesterol, serum glucose, and insulin between groups. Mangiferin supplementation could improve serum lipid profiles by reducing serum triglycerides and FFAs in overweight patients with hyperlipidemia, partly due to the promotion of FFAs oxidation.

  11. Mangiferin supplementation improves serum lipid profiles in overweight patients with hyperlipidemia: a double-blind randomized controlled trial

    PubMed Central

    Na, Lixin; Zhang, Qiao; Jiang, Shuo; Du, Shanshan; Zhang, Wei; Li, Ying; Sun, Changhao; Niu, Yucun

    2015-01-01

    Our previous studies have shown that mangiferin decreased serum triglycerides and free fatty acids (FFAs) by increasing FFAs oxidation in both animal and cell experiments. This study sought to evaluate the effects of mangiferin on serum lipid profiles in overweight patients with hyperlipidemia. Overweight patients with hyperlipidemia (serum triglyceride ≥ 1.70 mmol/L, and total cholesterol ≥ 5.2 mmol/L) were included in this double-blind randomized controlled trial. Participants were randomly allocated to groups, either receiving mangiferin (150 mg/day) or identical placebo for 12 weeks. The lipid profile and serum levels of mangiferin, glucose, L-carnitine, β-hydroxybutyrate, and acetoacetate were determined at baseline and 12 weeks. A total of 97 participants completed the trial. Compared with the placebo control, mangiferin supplementation significantly decreased the serum levels of triglycerides and FFAs, and insulin resistance index. Mangiferin supplementation also significantly increased the serum levels of mangiferin, high-density lipoprotein cholesterol, L-carnitine, β-hydroxybutyrate, and acetoacetate, and increased lipoprotein lipase activity. However, there were no differences in the serum levels of total cholesterol, low-density lipoprotein cholesterol, serum glucose, and insulin between groups. Mangiferin supplementation could improve serum lipid profiles by reducing serum triglycerides and FFAs in overweight patients with hyperlipidemia, partly due to the promotion of FFAs oxidation. PMID:25989216

  12. KETONES INHIBIT MITOCHONDRIAL PRODUCTION OF REACTIVE OXYGEN SPECIES PRODUCTION FOLLOWING GLUTAMATE EXCITOTOXICITY BY INCREASING NADH OXIDATION

    PubMed Central

    Maalouf, Marwan; Sullivan, Patrick G.; Davis, Laurie; Kim, Do Young; Rho, Jong M.

    2007-01-01

    Dietary protocols that increase serum levels of ketones, such as calorie restriction and the ketogenic diet, offer robust protection against a multitude of acute and chronic neurological diseases. The underlying mechanisms, however, remain unclear. Previous studies have suggested that the ketogenic diet may reduce free radical levels in the brain. Thus, one possibility is that ketones may mediate neuroprotection through antioxidant activity. In the present study, we examined the effects of the ketones β-hydroxybutyrate and acetoacetate on acutely dissociated rat neocortical neurons subjected to glutamate excitotoxicity using cellular electrophysiological and single-cell fluorescence imaging techniques. Further, we explored the effects of ketones on acutely isolated mitochondria exposed to high levels of calcium. A combination of β-hydroxybutyrate and acetoacetate (1 mM each) decreased neuronal death and prevented changes in neuronal membrane properties induced by 10 μM glutamate. Ketones also significantly decreased mitochondrial production of reactive oxygen species and the associated excitotoxic changes by increasing NADH oxidation in the mitochondrial respiratory chain, but did not affect levels of the endogenous antioxidant glutathione. In conclusion, we demonstrate that ketones reduce glutamate-induced free radical formation by increasing the NAD+/NADH ratio and enhancing mitochondrial respiration in neocortical neurons. This mechanism may, in part, contribute to the neuroprotective activity of ketones by restoring normal bioenergetic function in the face of oxidative stress. PMID:17240074

  13. Conformational analysis, tautomerization, IR, Raman, and NMR studies of benzyl acetoacetate

    NASA Astrophysics Data System (ADS)

    Tayyari, Sayyed Faramarz; Naghavi, Farnaz; Pojhan, Sahar; McClurg, Ryan W.; Sammelson, Robert E.

    2011-02-01

    A complete conformational analysis of the keto and enol forms of benzyl acetoacetate (BAA), a β-dicarbonyl compound, was carried out by ab initio calculations, at the density functional theory (DFT) level. By inspection of all possible conformers and tautomers, 22 stable cis-enol, 28 stable trans-enol, and five keto conformers were obtained. Among all stable cis-enol forms only six of them are engaged in intramolecular hydrogen bond. The hydrogen bond strength of the most stable conformer of BAA is compared with that of acetylacetone (AA) and dimethyl oxaloacetate (DMOA). Harmonic vibrational frequencies of the most stable enol and keto forms and their deuterated analogues were also calculated and compared with the experimental data. According to the theoretical calculations, the hydrogen bond strength of the most stable enol conformer of BAA is 56.7 kJ/mol (calculated at the B3LYP/6-311++G ∗∗ level), about 10 kJ/mol less than that of AA. This weakening of hydrogen bond is consistent with the spectroscopic results. NMR studies indicate that BAA exists mainly as a keto tautomer in all considered solutions. The Gibbs energies for keto/enol tautomerization were calculated at the B3LYP level, with several basis sets, in both gas phase and CH 3CN solution (using PCM model), for the most stable enol and keto conformers.

  14. The relationship of blood- and urine-boron to boron exposure in borax-workers and usefulness of urine-boron as an exposure marker.

    PubMed Central

    Culver, B D; Shen, P T; Taylor, T H; Lee-Feldstein, A; Anton-Culver, H; Strong, P L

    1994-01-01

    Daily dietary-boron intake and on-the-job inspired boron were compared with blood- and urine-boron concentrations in workers engaged in packaging and shipping borax. Fourteen workers handling borax at jobs of low, medium, and high dust exposures were sampled throughout full shifts for 5 consecutive days each. Airborne borax concentrations ranged from means of 3.3 mg/m3 to 18 mg/m3, measured gravimetrically. End-of-shift mean blood-boron concentrations ranged from 0.11 to 0.26 microgram/g; end-of-shift mean urine concentrations ranged from 3.16 to 10.72 micrograms/mg creatinine. Creatinine measures were used to adjust for differences in urine-specific gravity such that 1 ml of urine contains approximately 1 mg creatinine. There was no progressive increase in end-of-shift blood- or urine-boron concentrations across the days of the week. Urine testing done at the end of the work shift gave a somewhat better estimate of borate exposure than did blood testing, was sampled more easily, and was analytically less difficult to perform. Personal air samplers of two types were used: one, the 37-mm closed-face, two-piece cassette to estimate total dust and the other, the Institute of Occupational Medicine (IOM) sampler to estimate inspirable particulate mass. Under the conditions of this study, the IOM air sampler more nearly estimated human exposure as measured by blood- and urine-boron levels than did the sampler that measured total dust.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7889874

  15. Results for the Brine Evaporation Bag (BEB) Brine Processing Test

    NASA Technical Reports Server (NTRS)

    Delzeit, Lance; Flynn, Michael; Fisher, John; Shaw, Hali; Kawashima, Brian; Beeler, David; Howard, Kevin

    2015-01-01

    The recent Brine Processing Test compared the NASA Forward Osmosis Brine Dewatering (FOBD), Paragon Ionomer Water Processor (IWP), UMPQUA Ultrasonic Brine Dewatering System (UBDS), and the NASA Brine Evaporation Bag (BEB). This paper reports the results of the BEB. The BEB was operated at 70 deg C and a base pressure of 12 torr. The BEB was operated in a batch mode, and processed 0.4L of brine per batch. Two different brine feeds were tested, a chromic acid-urine brine and a chromic acid-urine-hygiene mix brine. The chromic acid-urine brine, known as the ISS Alternate Pretreatment Brine, had an average processing rate of 95 mL/hr with a specific power of 5kWhr/L. The complete results of these tests will be reported within this paper.

  16. Detection of illicit drugs in urine in the Division of Neonatology, Hospital Molas in La Pampa.

    PubMed

    Villarreal, Marina; Ré, Silvina

    2013-06-01

    There are few studies on the use of illicit drugs during pregnancy with a variable prevalence depending on the year, maternal age, region and diagnostic methods. Mothers' and newborn infants' urine samples were tested for illegal drugs in cases where the mother reported consumption, lack of antenatal care and neonatal signs and symptoms, from 2009 to 2011. A rapid strip test for simultaneous qualitative detection of multiple drugs and metabolites in urine was used. In 19 out of 39 (49%) cases in which urine samples were collected, an illicit drug was detected in the mother and/or the newborn infant. Cocaine was the most frequently detected drug. There was a high coexistence of social and familiar risk factors, smoking (84%) and alcohol consumption (47%).

  17. Protocol for accuracy of point of care (POC) or in-office urine drug testing (immunoassay) in chronic pain patients: a prospective analysis of immunoassay and liquid chromatography tandem mass spectometry (LC/MS/MS).

    PubMed

    Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D; Brandon, Doris E

    2010-01-01

    Therapeutic use, overuse, abuse, and diversion of controlled substances in managing chronic non-cancer pain continues to be an issue for physicians and patients. It has been stated that physicians, along with the public and federal, state, and local government; professional associations; and pharmaceutical companies all share responsibility for preventing abuse of controlled prescription drugs. The challenge is to eliminate or significantly curtail abuse of controlled prescription drugs while still assuring the proper treatment of those patients. A number of techniques, instruments, and tools have been described to monitor controlled substance use and abuse. Thus, multiple techniques and tools available for adherence monitoring include urine drug testing in conjunction with prescription monitoring programs and other screening tests. However, urine drug testing is associated with multiple methodological flaws. Multiple authors have provided conflicting results in relation to diagnostic accuracy with differing opinions about how to monitor adherence in a non-systematic fashion. Thus far, there have not been any studies systematically assessing the diagnostic accuracy of immunoassay with laboratory testing. A diagnostic accuracy study of urine drug testing. An interventional pain management practice, a specialty referral center, a private practice setting in the United States. To compare the information obtained by point of care (POC) or in-office urine drug testing (index test) to the information found when all drugs and analytes are tested by liquid chromatography tandem mass spectroscopy (LC/MS/MS) reference test in the same urine sample. The study is designed to include 1,000 patients with chronic pain receiving controlled substances. The primary outcome measure is the diagnostic accuracy. Patients will be tested for various controlled substances, including opioids, benzodiazepines, and illicit drugs. The diagnostic accuracy study is performed utilizing the Standards for Reporting of Diagnostic Accuracy Studies (STARD) initiative which established reporting guidelines for diagnostic accuracy studies to improve the quality of reporting. The prototypical flow diagram of diagnostic accuracy study as described by STARD will be utilized. Results of diagnostic accuracy and correlation of clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics will be calculated. The limitations include lack of availability of POC testing with lower cutoff levels. This article presents a protocol for a diagnostic accuracy study of urine drug testing. The protocol also will permit correlation of various clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics. NCT 01052155.

  18. [Detection of drugs in meconium].

    PubMed

    Dahlem, P; Bucher, H U; Ursprung, T; Mieth, D; Gautschi, K

    1992-06-01

    The number of newborn infants exposed to drugs in utero is on the increase in many European countries. As drug use reported by addicted pregnant women is unreliable there is a need for an accurate test to determine the drugs to which an infant has been exposed in utero. The purpose of this study was to evaluate the reliability of toxicology testing in meconium compared with traditional urine testing. From twenty newborn infants born to drug-dependent mothers, meconium and urine were collected as soon as possible after birth and tested for drugs with the same radioimmunoassay. Five neonates were premature (Gestational weeks less than 37), six were small and three microcephalic for gestational age. Meconium was positive for drugs in 19 infants (95%) (Methadone 9, Morphine 9, Cocaine 6, Cannabis 4). Urine testing revealed the presence of drugs in 13 babies (65%) (Methadone 9, Morphine 6, Cocaine 4, Cannabis 1, Barbiturates 1). Five infants did not have any drug withdrawal, five had mild and ten severe withdrawal symptoms necessitating treatment with chlorpromazine and in four instances additional pethidine. Meconium is not only easier to collect but also at least as reliable as urine for drug detection in neonates.

  19. Smartphone-Based Point-of-Care Urinalysis Under Variable Illumination

    PubMed Central

    Ra, Moonsoo; Lim, Chiawei; Han, Sehui; Jung, Chansung; Kim, Whoi-Yul

    2018-01-01

    Urine tests are performed by using an off-the-shelf reference sheet to compare the color of test strips. However, the tabular representation is difficult to use and more prone to visual errors, especially when the reference color-swatches to be compared are spatially apart. Thus, making it is difficult to distinguish between the subtle differences of shades on the reagent pads. This manuscript represents a new arrangement of reference arrays for urine test strips (urinalysis). Reference color swatches are grouped in a doughnut chart, surrounding each reagent pad on the strip. The urine test can be evaluated using naked eye by referring to the strip with no additional sheet necessary. Along with this new strip, an algorithm for smartphone based application is also proposed as an alternative to deliver diagnostic results. The proposed colorimetric detection method evaluates the captured image of the strip, under various color spaces and evaluates ten different tests for urine. Thus, the proposed system can deliver results on the spot using both naked eye and smartphone. The proposed scheme delivered accurate results under various environmental illumination conditions without any calibration requirements, exhibiting performances suitable for real-life applications and an ease for a common user. PMID:29333352

  20. Impaired Urine Dilution Capability in HIV Stable Patients

    PubMed Central

    Belloso, Waldo H.; de Paz Sierra, Mariana; Navarro, Matilde; Sanchez, Marisa L.; Perelsztein, Ariel G.; Musso, Carlos G.

    2014-01-01

    Renal disease is a well-recognized complication among patients with HIV infection. Viral infection itself and the use of some antiretroviral drugs contribute to this condition. The thick ascending limb of Henle's loop (TALH) is the tubule segment where free water clearance is generated, determining along with glomerular filtration rate the kidney's ability to dilute urine. Objective. We analyzed the function of the proximal tubule and TALH in patients with HIV infection receiving or not tenofovir-containing antiretroviral treatment in comparison with healthy seronegative controls, by applying a tubular physiological test, hyposaline infusion test (Chaimowitz' test). Material & Methods. Chaimowitz' test was performed on 20 HIV positive volunteers who had normal renal functional parameters. The control group included 10 healthy volunteers. Results. After the test, both HIV groups had a significant reduction of serum sodium and osmolarity compared with the control group. Free water clearance was lower and urine osmolarity was higher in both HIV+ groups. Proximal tubular function was normal in both studied groups. Conclusion. The present study documented that proximal tubule sodium reabsorption was preserved while free water clearance and maximal urine dilution capability were reduced in stable HIV patients treated or not with tenofovir. PMID:24800076

  1. A hybrid approach to urine drug testing using high-resolution mass spectrometry and select immunoassays.

    PubMed

    McMillin, Gwendolyn A; Marin, Stephanie J; Johnson-Davis, Kamisha L; Lawlor, Bryan G; Strathmann, Frederick G

    2015-02-01

    The major objective of this research was to propose a simplified approach for the evaluation of medication adherence in chronic pain management patients, using liquid chromatography time-of-flight (TOF) mass spectrometry, performed in parallel with select homogeneous enzyme immunoassays (HEIAs). We called it a "hybrid" approach to urine drug testing. The hybrid approach was defined based on anticipated positivity rates, availability of commercial reagents for HEIAs, and assay performance, particularly analytical sensitivity and specificity for drug(s) of interest. Subsequent to implementation of the hybrid approach, time to result was compared with that observed with other urine drug testing approaches. Opioids, benzodiazepines, zolpidem, amphetamine-like stimulants, and methylphenidate metabolite were detected by TOF mass spectrometry to maximize specificity and sensitivity of these 37 drug analytes. Barbiturates, cannabinoid metabolite, carisoprodol, cocaine metabolite, ethyl glucuronide, methadone, phencyclidine, propoxyphene, and tramadol were detected by HEIAs that performed adequately and/or for which positivity rates were very low. Time to result was significantly reduced compared with the traditional approach. The hybrid approach to urine drug testing provides a simplified and analytically specific testing process that minimizes the need for secondary confirmation. Copyright© by the American Society for Clinical Pathology.

  2. Cross-reactivity of stimulants found in sports drug testing by two fluorescence polarization immunoassays.

    PubMed

    de la Torre, R; Badia, R; Gonzàlez, G; García, M; Pretel, M J; Farré, M; Segura, J

    1996-01-01

    We investigated the usefulness of immunological methods for presumptive detection of stimulants found in sports drug testing. The ingestion of substances that show no cross-reactivity in tests commercially available for the detection of amphetamines can produce positive results in the urine. Human metabolism contributes to the positive results of some urine samples when the parent compound does not cross-react with the antibodies of the assay. Urine samples from healthy volunteers given stimulants were tested by chromatographic methods and by two different fluorescence polarization immunoassays (FPIA) from Abbott Laboratories for the analysis of amphetamines. According to the results obtained, we classified stimulants into four groups: detectable stimulants that gave rise to amphetamine by human metabolism (group 1); detectable ephedrines and related compounds, appearing in the urine either as parent compounds or originated by metabolism (group 2); detectable stimulants that displayed actual cross-reactivity with amphetamine tests (group 3); and stimulants not detected by FPIA (group 4). Most of the true doping cases due to the ingestion of stimulants may be detected by FPIA. The specificity of the results may be increased by combining immunological assays with different antibodies.

  3. Comparison of Four Strong Acids on the Precipitation Potential of Gypsum in Brines During Distillation of Pretreated, Augmented Urine

    NASA Technical Reports Server (NTRS)

    Muirhead, Dean

    2011-01-01

    Two batches of nominally pretreated and augmented urine were prepared with the baseline pretreatment formulation of sulfuric acid and chromium trioxide. The urine was augmented with inorganic salts and organic compounds in order to simulate a urinary ionic concentrations representing the upper 95 percentile on orbit. Three strong mineral acids: phosphoric, hydrochloric, and nitric acid, were substituted for the sulfuric acid for comparison to the baseline sulfuric acid pretreatment formulation. Three concentrations of oxidizer in the pretreatment formulation were also tested. Pretreated urine was distilled to 85% water recovery to determine the effect of each acid and its conjugate base on the precipitation of minerals during distillation. The brines were analyzed for calcium and sulfate ion, total, volatile, and fixed suspended solids. Test results verified that substitution of phosphoric, hydrochloric, or nitric acids for sulfuric acid would prevent the precipitation of gypsum up to 85% recovery from pretreated urine representing the upper 95 percentile calcium concentration on orbit.

  4. Laboratory aspects of asymptomatic bacteriuria in pregnancy.

    PubMed

    Mohammad, Marlyn; Mahdy, Zaleha A; Omar, Jamil; Maan, Noorashikin; Jamil, M A

    2002-09-01

    A total of 1,661 pregnant women aged between 13 and 45 years were screened for bacteriuria by urine culture. Of the 1,661 culture results, 615 (37%) yielded no growth; 728 (43.8%) yielded no significant growth (presence of <10(5) organisms/ml urine of one or more types of bacteria); 286 (17.2%) yielded mixed growth (presence of >10(5) organisms/ml urine of more than one type of bacteria) and only 32 (1.9%) showed significant growth (presence of >10(5) organisms/ml urine of a single bacterium). Urine microscopy was also conducted. Two hundred and twenty-four (13.5%) specimens had >10 white blood cells/ml urine, of which 66 had >100 white blood cells; 13 were from the significant growth group. Three hundred and seventy-four (22.5%) specimens showed the presence of bacteria, 42 (2.5%) had red blood cells, 370 (22.3%) had epithelial cells, 58 (3.5%) had crystals, and 14 (0.8%) had yeasts. The most common bacterium isolated was Escherichia coli (12; 40%); the others included group B Streptococcus (5; 15%), Klebsiella spp (5; 15%), Diphtheroids (2), and Candida albicans (2). Fifty-two percent of tested strains were sensitive to ampicillin; 24 of 28 strains (85.7%) were sensitive to ciprofloxacin; all 7 strains tested were sensitive to nitrofurantoin and all 20 strains tested were sensitive to cotrimoxazole; 14/20 (70%) and 16/17 (94.1%) were sensitive to cephalexin and cefuroxime respectively. This study shows that asymptomatic bacteriuria does occur in pregnant women, albeit at a very low rate in an urban setting like Cheras. Urine microscopy is not specific and only serves as a guide to bacteriuria. The commonest causative organisms are those from the gastrointestinal tract and vagina. The antibiogram showed that cefuroxime and cephalexin are likely to be effective in treating bacteriuria: ampicillin must be reserved for Gram-negative organisms. For Gram-positive organisms, of which Group B Streptococcus is important, ampicillin is still effective in vitro. Nitrofurantion and cotrimoxazole have excellent activity in vitro and should be considered for therapy. 17.2% of the urine culture yielded mixed growth: likely to indicate that contamination of urine specimens still happens despite the strict instructions given to patients about the collection of a midstream urine specimen. Proper collection, appropriate transport, and the early processing of urine specimens remain essential.

  5. Removal of ammonia from urine vapor by a dual-catalyst system

    NASA Technical Reports Server (NTRS)

    Budininkas, P.

    1977-01-01

    The feasibility of removing ammonia from urine vapor by a low-temperature dual-catalyst system has been demonstrated. The process is based on the catalytic oxidation of ammonia to a mixture of nitrogen, nitrous oxide, and water, followed by a catalytic decomposition of the nitrous oxide into its elements. Potential ammonia oxidation and nitrous oxide decomposition catalysts were first screened with artificial gas mixtures, then tested with the actual urine vapor produced by boiling untreated urine. A suitable dual-catalyst bed arrangement was found that achieved the removal of ammonia and also organic carbon, and recovered water of good quality from urine vapor.

  6. 21 CFR 862.1665 - Sodium test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment... excretion of large amounts of dilute urine, accompanied by extreme thirst), adrenal hypertension, Addison's...

  7. 21 CFR 862.1375 - Histidine test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... free histidine (an amino acid) in plasma and urine. Histidine measurements are used in the diagnosis and treatment of hereditary histidinemia characterized by excess histidine in the blood and urine...

  8. 21 CFR 862.1665 - Sodium test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment... excretion of large amounts of dilute urine, accompanied by extreme thirst), adrenal hypertension, Addison's...

  9. 21 CFR 862.1375 - Histidine test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... free histidine (an amino acid) in plasma and urine. Histidine measurements are used in the diagnosis and treatment of hereditary histidinemia characterized by excess histidine in the blood and urine...

  10. 21 CFR 862.1285 - Etiocholanolone test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... intended to measure etiocholanolone in serum and urine. Etiocholanolone is a metabolic product of the hormone testosterone and is excreted in the urine. Etiocholanolone measurements are used in the diagnosis...

  11. Glomerulonephritis (For Parents)

    MedlinePlus

    ... a doctor right away to find the cause. Diagnosis At the doctor's office, explain your child's symptoms. ... Phosphorus Blood in the Urine (Hematuria) Living With Lupus Urine Tests Chronic Kidney Diseases Your Urinary System ...

  12. Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice.

    PubMed

    Schot, Marjolein J C; van Delft, Sanne; Kooijman-Buiting, Antoinette M J; de Wit, Niek J; Hopstaken, Rogier M

    2015-05-18

    Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Intraindividual stability of cortisol and cortisone and the ratio of cortisol to cortisone in saliva, urine and hair.

    PubMed

    Zhang, Quan; Chen, Zheng; Chen, Shenghuo; Xu, Youyun; Deng, Huihua

    2017-02-01

    Cortisol, cortisone and the ratio of cortisol to cortisone in saliva, urine and hair are acute, short-term and long-term biomarkers to reliably assess the activity of hypothalamic-pituitary-adrenal (HPA) axis and 11β-hydroxysteroid dehydrogenase (11β-HSD). One key issue is whether these biomarkers have intraindividual relative stability. Salivary, urinary and hair cortisol was proven to show considerable long-term intraindividual relative stability. However, currently unknown is whether cortisone and the ratio in saliva, urine and hair show intraindividual relative stability. The present study utilized a longitudinal design to validate long-term stability within two weeks of three biomarkers in saliva and urine, and long-term stability within twelve months of three hair biomarkers. Salivary, urinary and hair steroids were measured with high performance liquid chromatography tandem mass spectrometry. Three biomarkers in urine and hair showed moderate test-retest correlations with coefficient (r) ranging between 0.22 and 0.56 and good multiple-test consistencies with coefficient of intraclass correlation (ICC) ranging between 0.42 and 0.67. Three single-point salivary biomarkers showed weak to moderate test-retest correlations (r's between 0.01 and 0.38) and poor to fair multiple-test consistencies (ICC's between 0.29 and 0.53) within two weeks. Three single-day salivary biomarkers showed moderate test-retest correlations (r's between 0.23 and 0.53) and good multiple-test consistencies (ICC's between 0.56 and 0.66) within two weeks. Three biomarkers in urine and hair showed moderate long-term intraindividual relative stability. Three single-point salivary biomarkers showed weak to moderate short-term and long-term intraindividual relative stability, but three single-day salivary biomarkers showed moderate short-term and long-term intraindividual relative stability. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Diagnostic accuracy of rapid urine dipstick test to predict urinary tract infection among pregnant women in Felege Hiwot Referral Hospital, Bahir Dar, North West Ethiopia.

    PubMed

    Demilie, Tazebew; Beyene, Getenet; Melaku, Selabat; Tsegaye, Wondewosen

    2014-07-29

    Untreated bacteriuria during pregnancy has been shown to be associated with low birth-weight and premature delivery. Therefore, routine screening for bacteriuria is advocated. The decision about how to screen pregnant women for bacteriuria has always been a balance between the cost of screening versus the sensitivity and specificity. This study was designed to evaluate the diagnostic accuracy of the rapid dipstick test to predict urinary tract infection in pregnancy against the gold standard urine culture. A total of 367 mid stream urine samples were collected, inoculated on MacConkey, Manitol salt agar (MSA) and blood agar and incubated aerobically at 37°C for overnight. Specimens were classified as "positive" for urinary tract infection (UTI) if the growth of the pathogen(s) was at a count ≥ 10(5) colony-forming units per milliliter (cfu/mL) of urine and classified as "negative" with growth of <10(5) cfu/mL. Urine samples were tested for the presence of nitrite and leukocyte esterase using dipstick rapid test in accordance to the manufacturer's instructions. From the total study participants, 37 pregnant women were symptomatic and the remaining 330 pregnant women were asymptomatic. The sensitivity and specificity of dipstick tests of leukocyte esterase was 50% and 89.1% for pregnant women with asymptomatic UTI(ABU) and 71.4% and 86.7% for symptomatic UTI respectively and for nitrite 35.7% and 98.0% for ABU and 57.1% and 96.7% symptomatic UTI. This study revealed that the use of dipstick leukocyte esterase and nitrite for screening UTI particularly asymptomatic bacteriuria was associated with many false positive and negative results when it was compared against the gold standard culture method. The low sensitivity and positive predictive value of urine dipstick test proved that culture should be used for the diagnosis of UTI.

  15. Correlation of Urine Biomarkers: Microalbuminuria and Spot Urine Protein among Diabetic Patients. Application of Spot Urine Protein in Diabetic Kidney Disease, Nephropathy, Proteinuria Estimation, Diagnosing and Monitoring.

    PubMed

    Aziz, Kamran M A

    2015-01-01

    Current study has invented a new method for utilizing spot urine protein among diabetic patients. There have been various efforts and strategies in research internationally to detect, diagnose and monitor nephropathy/DKD. Although 24-hour urine studies are gold standard, however, there exist some controversies about microalbuminuria and spot urine protein. The current study was designed to utilize spot urine protein among diabetic patients and to find its association with routine dipstick urine test for albumin, and microalbuminuria. The study demonstrated significant association of spot urine protein with urine dipstick albumin, and has demonstrated increasing spot urine protein with increasing albumin in urine (p-value < 0.0001). This study also demonstrated significantly higher levels of spot urine protein between the groups with nephropathy/DKD as compared to those without nephropathy/DKD (p-value < 0.0001). Similarly, spot urine protein and spot urine protein/creatinine were also significantly associated with microalbumin and microalbumin/creatinine in urine. Significant regression models for spot urine protein and microalbuminuria were also developed and proposed to detect and estimate microalbumin in urine while utilizing spot urine protein (< 0.0001). Synthesized regression equations and models can be used confidently to detect, rule out and monitor proteinuria and DKD. ROC curves were utilized to detect spot urine protein cutoff points for nephropathy and DKD with high specificity and sensitivity. Some important patents were also discussed in the paper regarding albuminuria/proteinuria detection and management. Current study has demonstrated and concluded, for the first time, that there exists a significant association of spot urine protein with routine dipstick albumin in urine and microalbuminuria. It is also essential to detect early, monitor and manage proteinuria, hypertension and dyslipidemia with good glycemic control to prevent diabetes complications.

  16. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis

    PubMed Central

    Chaya, DR; Parija, Subhash Chandra

    2013-01-01

    Introduction: Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. Materials and Methods: A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. Results: The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. Conclusions: ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE. PMID:24470996

  17. 24-hour urine protein

    MedlinePlus

    ... one urine sample (protein-to-creatinine ratio). Normal Results The normal value is less than 100 milligrams ... meaning of your specific test results. What Abnormal Results Mean Abnormal results may be due to: A ...

  18. New and developing diagnostic technologies for urinary tract infections

    PubMed Central

    Davenport, Michael; Mach, Kathleen E.; Dairiki Shortliffe, Linda M.; Banaei, Niaz; Wang, Tza-Huei; Liao, Joseph C.

    2017-01-01

    Timely and accurate identification and determination of the antimicrobial susceptibility of uropathogens is central to the management of UTIs. Urine dipsticks are fast and amenable to point-of-care testing, but do not have adequate diagnostic accuracy or provide microbiological diagnosis. Urine culture with antimicrobial susceptibility testing takes 2 3 days and requires a clinical laboratory. The common use of empirical antibiotics has contributed to the rise of multidrug-resistant organisms, reducing treatment options and increasing costs. In addition to improved antimicrobial stewardship and the development of new antimicrobials, novel diagnostics are needed for timely microbial identification and determination of antimicrobial susceptibilities. New diagnostic platforms, including nucleic acid tests and mass spectrometry, have been approved for clinical use and have improved the speed and accuracy of pathogen identification from primary cultures. Optimization for direct urine testing would reduce the time to diagnosis, yet these technologies do not provide comprehensive information on antimicrobial susceptibility. Emerging technologies including biosensors, microfluidics, and other integrated platforms could improve UTI diagnosis via direct pathogen detection from urine samples, rapid antimicrobial susceptibility testing, and point-of-care testing. Successful development and implementation of these technologies has the potential to usher in an era of precision medicine to improve patient care and public health. PMID:28248946

  19. 49 CFR 40.65 - What does the collector check for when the employee presents a specimen?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...

  20. 49 CFR 40.65 - What does the collector check for when the employee presents a specimen?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...

  1. 49 CFR 40.65 - What does the collector check for when the employee presents a specimen?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...

  2. 49 CFR 40.65 - What does the collector check for when the employee presents a specimen?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...

  3. 49 CFR 40.65 - What does the collector check for when the employee presents a specimen?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...

  4. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... shipping of urine specimens to a laboratory, and a suitable clean surface for writing. (d) Your collection... section. (e) The first, and preferred, type of facility for urination that a collection site may include... event of a directly observed collection. (2) You must have a source of water for washing hands, that, if...

  5. Development of an immunochromatographic assay for the β-adrenergic agonist feed additive zilpaterol.

    PubMed

    Shelver, Weilin L; Smith, David J

    2018-06-06

    Zilpaterol is a β-adrenergic agonist feed additive approved in the United States to increase weight gain and improve feed efficiency of cattle. A zilpaterol immunochromatographic assay was developed as an economical and user-friendly rapid detection method for zilpaterol and validated using urine and tissue samples derived from animal studies. The assay sensitivity was 1.7-23.2 ng g -1 or mL -1 across a variety of feed and animal matrices and did not cross-react with clenbuterol or ractopamine. No sample pre-treatment of cattle and sheep urine was needed, but horse urine and feed required dilution; skeletal muscle required solvent extraction prior to testing. Of 32 incurred sheep urine samples tested, zilpaterol content was correctly identified in all but 2 samples. Horse urine containing >10 ng mL -1 of incurred zilpaterol residue (n = 48) was correctly identified as zilpaterol positive. The assay correctly identified 0-day withdrawal sheep muscle samples as zilpaterol positive and the control and longer withdrawal day sheep muscle samples as negative. Zilpaterol was demonstrated to be stable in horse urine when stored at -20°C for 7 years.

  6. Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens

    PubMed Central

    Tanaka, M.; Nakayama, H.; Sagiyama, K.; Haraoka, M.; Yoshida, H.; Hagiwara, T.; Akazawa, K.; Naito, S.

    2000-01-01

    Aims—To compare the performance of a new generation dual amplified enzyme immunoassay (EIA) with a molecular method for the diagnosis of Chlamydia trachomatis, using a range of urogenital samples, and to assess the reliability of testing self collected vaginal specimens compared with clinician collected vaginal specimens. Methods—Two population groups were tested. For the first population group, first void urine samples were collected from 193 male patients with urethritis, and endocervical swabs were collected from 187 high risk commercial sex workers. All urine and endocervical specimens were tested by a conventional assay (IDEIA chlamydia), a new generation amplified immunoassay (IDEIA PCE chlamydia), and the Amplicor polymerase chain reaction (PCR). Discrepant results obtained among the three sample types were confirmed using a nested PCR test with a different plasmid target region. For the second population group, four swab specimens, including one patient obtained vaginal swab, two clinician obtained endocervical swabs, and one clinician obtained vaginal swab, were collected from 91 high risk sex workers. Self collected and clinician collected vaginal swabs were tested by IDEIA PCE chlamydia. Clinician obtained endocervical swabs were assayed by IDEIA PCE chlamydia and Amplicor PCR. Results—The performance of the IDEIA PCE chlamydia test was comparable to that of the Amplicor PCR test when male urine and female endocervical swab specimens were analysed. The relative sensitivities of IDEIA, IDEIA PCE, and Amplicor PCR on male first void urine specimens were 79.3%, 91.4%, and 100%, respectively. The relative sensitivities of the three tests on female endocervical specimens were 85.0%, 95.0%, and 100%, respectively. The positivity rates for patient collected vaginal specimens and clinician collected vaginal specimens by IDEIA PCE were 25.2% and 23.1%, respectively, whereas those for clinician collected endocervical swabs by PCR and IDEIA PCE were both 27.5%. Conclusions—IDEIA PCE chlamydia is a lower cost but sensitive alternative test to PCR for testing male urine samples and female endocervical swabs. In addition, self collected or clinician collected vaginal specimens tested by IDEIA PCE chlamydia are a reliable alternative to analysing endocervical specimens. Key Words: Chlamydia trachomatis • enzyme immunoassay • clinical specimens PMID:10889816

  7. Substitution of human for horse urine disproves an accusation of doping*.

    PubMed

    Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo

    2008-09-01

    In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.

  8. Four-man rated dual catalyst system for the recovery of water from urine

    NASA Technical Reports Server (NTRS)

    Budininkas, P.

    1978-01-01

    The catalytic system was integrated with a 4-man rated urine wick evaporator. During operation, urine vapor produced by the wick-evaporator was treated in the catalytic system to remove ammonia and volatile hydrocarbons, and water was recovered by condensation in a water cooled condenser. The system operated completely automatically and required no manual adjustments, except periodic supply of urine and removal of the recovered water. Although the system was designed for treating 0.325 kg urine per hour, this rate could be achieved only with a fresh wick, then gradually decreased as the wick became saturated with urine solids. The average urine treatment rates achieved during each of the three endurance tests were 0.137, 0.217, and 0.235 kg/hr. The quality of the recovered water meets drinking water standards, with the exception of a generally low pH.

  9. Coca tea consumption causes positive urine cocaine assay.

    PubMed

    Mazor, Suzan S; Mycyk, Mark B; Wills, Brandon K; Brace, Larry D; Gussow, Leon; Erickson, Timothy

    2006-12-01

    Coca tea, derived from the same plant that is used to synthesize cocaine, is commonly consumed in South America and easily obtained in the United States. To determine whether consumption of coca tea would result in a positive urine toxicology screen for cocaine metabolites. Five healthy adult volunteers consumed coca tea and underwent serial quantitative urine testing for cocaine metabolites by fluorescence polarization immunoassay. The cutoff for a positive assay was chosen at 300 ng/ml, the National Institute on Drug Abuse standard. Each participant's urine cocaine assay was positive (level exceeding 300 ng/ml) by 2 h after ingestion. Three out of five participants' samples remained positive at 36 h. Mean urine benzoylecgonine concentrations in all postconsumption samples was 1777 ng/ml (95% confidence interval: 1060-2495). Coca tea ingestion resulted in a positive urine assay for cocaine metabolite. Healthcare professionals should consider a history of coca tea ingestion when interpreting urine toxicology results.

  10. Stabilization of source-separated human urine by chemical oxidation.

    PubMed

    Zhang, Yang; Li, Zifu; Zhao, Yuan; Chen, Shuangling; Mahmood, Ibrahim Babatunde

    2013-01-01

    The inhibitory effect of ozone and hydrogen peroxide (HP) on urea hydrolysis in stored urine was investigated and compared. Ozone showed less effect on urea hydrolysis due to the complicated composition of urine (including a large amount of urease-producing bacteria) and bacteria regeneration. Ozone concentration and total heterotrophic bacteria analysis demonstrated that residual ozone concentration decreased by 43% within 15 hr from 13.50 to 7.72 mg/L in the one-time ozonation urine test, and finally completely decomposed within 4 days. In addition, bacteria regenerated quickly after ozone completely decomposed. However, HP showed a significant effect on inhibiting urea hydrolysis not only in stored urine but also in fecal-contaminated urine. The suitable doses of applied HP to inhibit urea hydrolysis in stored urine, concentrations of 0.5 and 1.0 g feces per liter of fecal-contaminated urine, were 0.03, 0.16 and 0.23 mol/L, respectively. The urea concentrations after 2 months stored were 7,145, 7,109 and 7,234 mg/L, respectively.

  11. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  12. The value of urine specific gravity in detecting diabetes insipidus in a patient with uncontrolled diabetes mellitus: urine specific gravity in differential diagnosis.

    PubMed

    Akarsu, Ersin; Buyukhatipoglu, Hakan; Aktaran, Sebnem; Geyik, Ramazan

    2006-11-01

    When a patient with diabetes mellitus presents with worsening polyuria and polydipsia, what is a sensible, cost-effective approach? We report the unique coincidence of type 2 diabetes mellitus and diabetes insipidus. A 46-year-old woman with poorly controlled type 2 diabetes complained of polyuria with a daily output of 5 L. Although urinalysis demonstrated significant glucosuria, diabetes insipidus was suspected owing to a low urine specific gravity (1.008). The low specific gravity persisted during a water deprivation test. Ultimately, diabetes insipidus was confirmed when urine specific gravity and urine osmolality normalized following desmopressin administration. This case emphasizes the importance of accurately interpreting the urine specific gravity in patients with polyuria and diabetes mellitus to detect diabetes insipidus.

  13. 75 FR 22150 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Substance Abuse and Mental Health Services Administration Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal Agencies Correction In notice document 2010-7170 beginning on page 16813 in the issue of Friday, April 2...

  14. The fascinating story of urine examination: From uroscopy to the era of microscopy and beyond.

    PubMed

    Magiorkinis, Emmanouil; Diamantis, Aristidis

    2015-12-01

    The purpose of this study was to present the evolution of ideas on the examination of urine from antiquity till our days. A thorough study of texts, medical books from antiquity till twentieth century along with a thorough review of the available literature in PubMed was conducted. The first observation on urine examination can be traced back to the Babylonian and Sumerian texts. Almost all physicians in antiquity including Hippocrates referred to the value of urine examination in the diagnosis and prognosis of diseases. The construction of first compound microscope lead to the examination of urine sediment and the development of Urine Cytology which was revolutionized during the twentieth century with the studies of important cytologists such as George Papanicolaou, Geoffrey Krabbe, and Leopold Koss. The introduction of molecular tests in the diagnosis of urothelial cancer inaugurated a new era in the study of urine cytology. The history of urine examination spans a period of 6,000 years. The application of microscope in the examination of urine sediment during the nineteenth century established urine analysis as an important diagnostic tool in clinical practice. © 2015 Wiley Periodicals, Inc.

  15. Naltrexone treatment for opioid dependence: does its effectiveness depend on testing the blockade?

    PubMed

    Sullivan, Maria A; Bisaga, Adam; Mariani, John J; Glass, Andrew; Levin, Frances R; Comer, Sandra D; Nunes, Edward V

    2013-11-01

    FDA approval of long-acting injectable naltrexone (Vivitrol) for opioid dependence highlights the relevance of understanding mechanisms of antagonist treatment. Principles of learning suggest an antagonist works through extinguishing drug-seeking behavior, as episodes of drug use ("testing the blockade") fail to produce reinforcement. We hypothesized that opiate use would moderate the effect of naltrexone, specifically, that opiate-positive urines precede dropout in the placebo group, but not in the active-medication groups. An 8-week, double-blind, placebo-controlled trial (N=57), compared the efficacy of low (192 mg) and high (384 mg) doses of a long-acting injectable naltrexone (Depotrex) with placebo (Comer et al., 2006). A Cox proportional hazard model was fit, modeling time-to-dropout as a function of treatment assignment and urine toxicology during treatment. Interaction of opiate urines with treatment group was significant. Opiate-positive urines predicted dropout on placebo and low-dose, but less so on high-dose naltrexone, where positive urines were more likely followed by sustained abstinence. Among patients with no opiate-positive urines, retention was higher in both low- and high-dose naltrexone conditions, compared to placebo. Findings confirm that injection naltrexone produces extinction of drug-seeking behavior after episodes of opiate use. Adequate dosage appears important, as low-dose naltrexone resembled the placebo group; opiate positive urines were likely to be followed by dropout from treatment. The observation of high treatment retention among naltrexone-treated patients who do not test the blockade, suggests naltrexone may also exert direct effects on opiate-taking behavior that do not depend on extinction, perhaps by attenuating craving or normalizing dysregulated hedonic or neuroendocrine systems. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Naltrexone treatment for opioid dependence: Does its effectiveness depend on testing the blockade?

    PubMed Central

    Sullivan, Maria A.; Bisaga, Adam; Mariani, John J.; Glass, Andrew; Levin, Frances R.; Comer, Sandra D.; Nunes, Edward V.

    2013-01-01

    Background FDA approval of long-acting injectable naltrexone (Vivitrol) for opioid dependence highlights the relevance of understanding mechanisms of antagonist treatment. Principles of learning suggest an antagonist works through extinguishing drug-seeking behavior, as episodes of drug use (“testing the blockade”) fail to produce reinforcement. We hypothesized that opiate use would moderate the effect of naltrexone, specifically, that opiate-positive urines precede dropout in the placebo group, but not in the active-medication groups. Methods An 8-week, double-blind, placebo-controlled trial (N=57), compared the efficacy of low (192-mg) and high (384-mg) doses of a long-acting injectable naltrexone (Depotrex) with placebo (Comer et al., 2006). A Cox proportional hazard model was fit, modeling time-to-dropout as a function of treatment assignment and urine toxicology during treatment. Results Interaction of opiate urines with treatment group was significant. Opiate-positive urines predicted dropout on placebo and low-dose, but less so on high-dose naltrexone, where positive urines were more likely followed by sustained abstinence. Among patients with no opiate-positive urines, retention was higher in both low- and high-dose naltrexone conditions, compared to placebo. Conclusions Findings confirm that injection naltrexone produces extinction of drug-seeking behavior after episodes of opiate use. Adequate dosage appears important, as low-dose naltrexone resembled the placebo group; opiate positive urines were likely to be followed by dropout from treatment. The observation of high treatment retention among naltrexone-treated patients who do not test the blockade, suggests naltrexone may also exert direct effects on opiate-taking behavior that do not depend on extinction, perhaps by attenuating craving or normalizing dysregulated hedonic or neuroendocrine systems. PMID:23827259

  17. Diagnostic accuracy of uriSed automated urine microscopic sediment analyzer and dipstick parameters in predicting urine culture test results.

    PubMed

    Huysal, Kağan; Budak, Yasemin U; Karaca, Ayse Ulusoy; Aydos, Murat; Kahvecioğlu, Serdar; Bulut, Mehtap; Polat, Murat

    2013-01-01

    Urinary tract infection (UTI) is one of the most common types of infection. Currently, diagnosis is primarily based on microbiologic culture, which is time- and labor-consuming. The aim of this study was to assess the diagnostic accuracy of urinalysis results from UriSed (77 Electronica, Budapest, Hungary), an automated microscopic image-based sediment analyzer, in predicting positive urine cultures. We examined a total of 384 urine specimens from hospitalized patients and outpatients attending our hospital on the same day for urinalysis, dipstick tests and semi-quantitative urine culture. The urinalysis results were compared with those of conventional semiquantitative urine culture. Of 384 urinary specimens, 68 were positive for bacteriuria by culture, and were thus considered true positives. Comparison of these results with those obtained from the UriSed analyzer indicated that the analyzer had a specificity of 91.1%, a sensitivity of 47.0%, a positive predictive value (PPV) of 53.3% (95% confidence interval (CI) = 40.8-65.3), and a negative predictive value (NPV) of 88.8% (95% CI = 85.0-91.8%). The accuracy was 83.3% when the urine leukocyte parameter was used, 76.8% when bacteriuria analysis of urinary sediment was used, and 85.1% when the bacteriuria and leukocyturia parameters were combined. The presence of nitrite was the best indicator of culture positivity (99.3% specificity) but had a negative likelihood ratio of 0.7, indicating that it was not a reliable clinical test. Although the specificity of the UriSed analyzer was within acceptable limits, the sensitivity value was low. Thus, UriSed urinalysis resuIts do not accurately predict the outcome of culture.

  18. Effectiveness of saliva and fingerprints as alternative specimens to urine and blood in forensic drug testing.

    PubMed

    Kuwayama, Kenji; Miyaguchi, Hajime; Yamamuro, Tadashi; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki

    2016-07-01

    In forensic drug testing, it is important to immediately take biological specimens from suspects and victims to prove their drug intake. We evaluated the effectiveness of saliva and fingerprints as alternative specimens to urine and blood in terms of ease of sampling, drug detection sensitivity, and drug detection periods for each specimen type. After four commercially available pharmaceutical products were administered to healthy subjects, each in a single dose, their urine, blood, saliva, and fingerprints were taken at predetermined sampling times over approximately four weeks. Fourteen analytes (the administered drugs and their main metabolites) were extracted from each specimen using simple pretreatments, such as dilution and deproteinization, and were analyzed using liquid chromatography/mass spectrometry (LC/MS). Most of the analytes were detected in saliva and fingerprints, as well as in urine and blood. The time-courses of drug concentrations were similar between urine and fingerprints, and between blood and saliva. Compared to the other compounds, the acidic compounds, for example ibuprofen, acetylsalicylic acid, were more difficult to detect in all specimens. Acetaminophen, dihydrocodeine, and methylephedrine were detected in fingerprints at later sampling times than in urine. However, a relationship between the drug structures and their detection periods in each specimen was not found. Saliva and fingerprints could be easily sampled on site without using special techniques or facilities. In addition, fingerprints could be immediately analyzed after simple and rapid treatment. In cases where it would be difficult to immediately obtain urine and blood, saliva and fingerprints could be effective alternative specimens for drug testing. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Urine chromium as an estimator of air exposure to stainless steel welding fumes.

    PubMed

    Sjögren, B; Hedström, L; Ulfvarson, U

    1983-01-01

    Welding stainless steel with covered electrodes, also called manual metal arc welding, generates hexavalent airborne chromium. Chromium concentrations in air and post-shift urine samples, collected the same arbitrarily chosen working day, showed a linear relationship. Since post-shift urine samples reflect chromium concentrations of both current and previous stainless steel welding fume exposure, individual urine measurements are suggested as approximate although not exact estimators of current exposure. This study evaluates the practical importance of such measurements by means of confidence limits and tests of validity.

  20. Spacelab 4: Primate experiment support hardware

    NASA Astrophysics Data System (ADS)

    Fusco, P. R.; Peyran, R. J.

    1984-05-01

    A squirrel monkey feeder and automatic urine collection system were designed to fly on the Spacelab 4 Shuttle Mission presently scheduled for January 1986. Prototypes of the feeder and urine collection systems were fabricated and extensively tested on squirrel monkeys at the National Aeronautics and Space Administration's (NASA) Ames Research Center (ARC). The feeder design minimizes impact on the monkey's limited space in the cage and features improved reliability and biocompatibility over previous systems. The urine collection system is the first flight qualified, automatic urine collection device for squirrel monkeys. Flight systems are currently being fabricated.

  1. Spacelab 4: Primate experiment support hardware

    NASA Technical Reports Server (NTRS)

    Fusco, P. R.; Peyran, R. J.

    1984-01-01

    A squirrel monkey feeder and automatic urine collection system were designed to fly on the Spacelab 4 Shuttle Mission presently scheduled for January 1986. Prototypes of the feeder and urine collection systems were fabricated and extensively tested on squirrel monkeys at the National Aeronautics and Space Administration's (NASA) Ames Research Center (ARC). The feeder design minimizes impact on the monkey's limited space in the cage and features improved reliability and biocompatibility over previous systems. The urine collection system is the first flight qualified, automatic urine collection device for squirrel monkeys. Flight systems are currently being fabricated.

  2. 28 CFR 550.40 - Purpose and scope.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.40... community treatment center (CTC) participate in a program of urine testing for drug use. An inmate who is...

  3. 28 CFR 550.40 - Purpose and scope.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.40... community treatment center (CTC) participate in a program of urine testing for drug use. An inmate who is...

  4. 21 CFR 862.1590 - Porphobilinogen test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... intended to measure porphobilinogen (one of the derivatives of hemoglobin which can make the urine a red color) in urine. Measurements obtained by this device are used in the diagnosis and treatment of...

  5. 28 CFR 550.40 - Purpose and scope.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.40... community treatment center (CTC) participate in a program of urine testing for drug use. An inmate who is...

  6. 21 CFR 862.1377 - Urinary homocystine (nonquantitative) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... analogue of the amino acid cystine) in urine. The identification of urinary homocystine is used in the diagnosis and treatment of homocystinuria (homosystine in urine), a heritable metabolic disorder which may...

  7. 21 CFR 862.1377 - Urinary homocystine (nonquantitative) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... analogue of the amino acid cystine) in urine. The identification of urinary homocystine is used in the diagnosis and treatment of homocystinuria (homosystine in urine), a heritable metabolic disorder which may...

  8. 21 CFR 862.1590 - Porphobilinogen test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... intended to measure porphobilinogen (one of the derivatives of hemoglobin which can make the urine a red color) in urine. Measurements obtained by this device are used in the diagnosis and treatment of...

  9. 21 CFR 862.1590 - Porphobilinogen test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... intended to measure porphobilinogen (one of the derivatives of hemoglobin which can make the urine a red color) in urine. Measurements obtained by this device are used in the diagnosis and treatment of...

  10. 28 CFR 550.40 - Purpose and scope.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.40... community treatment center (CTC) participate in a program of urine testing for drug use. An inmate who is...

  11. Potassium urine test

    MedlinePlus

    ... in the clinical evaluation of electrolyte, water, and acid-base disorders. In: Alpern RJ, Orson WM, Caplan M, ... Lin S-H, Halperin ML. Interpretation of electrolyte and acid-base parameters in blood and urine. In: Skorecki K, ...

  12. Detection of drugs in the urine of body-packers.

    PubMed

    Gherardi, R K; Baud, F J; Leporc, P; Marc, B; Dupeyron, J P; Diamant-Berger, O

    1988-05-14

    The presence of opiates and benzoylecgonine, the major metabolite of cocaine, in the urine was detected by means of enzyme immunoassay in a series of 120 smugglers who had either ingested or inserted into their rectum cocaine or heroin packaged for transportation. There was a striking relation between the presence of drugs in the urine and swallowing of drug-filled bundles (cocaine 49 of 50 cases, heroin 9 of 10). The proportion of positive results was also high in cases of rectal insertion (cocaine 2 of 2, heroin 35 of 58). In 30 cases of cocaine-packet ingestion, serial measurements showed that the accuracy of the test progressively decreased with respect to the detection of residual packets in the body. Drug detection in the urine of suspected body-packers seems to be a useful test, positive results justifying subsequent radiological investigations.

  13. Devices for home evaluation of women's health concerns.

    PubMed

    Scolaro, Kelly L; Lloyd, Kimberly Braxton; Helms, Kristen L

    2008-02-15

    Devices used for home evaluation of fertility, pregnancy, menopause, colon cancer, breast cancer, and urinary-tract and vaginal yeast infections are discussed. Ovulation-prediction devices monitor natural changes in a woman's body during the menstrual cycle, including changes in basal body temperature, urinary luteinizing hormone, and urinary estrone-3-glucuronide concentrations. Also available are devices that identify changes in the content of sodium chloride and other electrolytes in saliva and cervical-vaginal mucus. Home pregnancy tests are designed to detect human chorionic gonadotropin in the urine. Both urine and saliva tests are available for home evaluation of menopause; the most common devices use urine to measure follicle-stimulating hormone. The saliva tests measure estradiol, progesterone, and testosterone. Devices for home screening for colon cancer use either the guaiac test or the fecal immunochemical test. For aid in breast self-examination, patients may use a simulated-breast product designed to train them to detect lumps or a thin, silicone-containing pad intended to increase the sensitivity of the fingers to abnormalities. Urine-dipstick tests can be used to screen for urinary-tract infection, and a swab or panty liner can be used to detect vaginal pH changes indicative of vaginal yeast infection. Home-based tests may be convenient and economical but also have limitations; pharmacists can help educate patients and clinicians. Many devices are available to help evaluate women's health concerns at home.

  14. Interpretation of urine drug testing results in patients using transdermal buprenorphine preparations for the treatment of chronic noncancer pain.

    PubMed

    Markman, John D; Barbosa, William A; Gewandter, Jennifer S; Frazer, Maria; Rast, Shirley; Dugan, Michelle; Nandigam, Kiran; Villareal, Armando; Kwong, Tai C

    2015-06-01

    To determine whether the prevailing liquid chromatography and tandem mass spectroscopy assay (LC-MS/MS) assay designed to monitor buprenorphine compliance of the sublingual formulation used in the substance abuse treatment setting can be extrapolated to the transdermal formulation used in the chronic pain treatment setting, which is 1000-fold less concentrated. Retrospective chart review. Self-reported compliant patients using the transdermal or sublingual formulations of buprenorhphine. Transdermal patch application was also visually confirmed during clinic visits. Urine drug test results from a LC-MS/MS were compared between samples from transdermal and sublingual patients. While all sublingual patients tested positive for at least one metabolite of buprenorphine, only 69% of the transdermal patients did so. In addition, the most abundant metabolite in the transdermal patients was buprenorphine-glucuronide, as compared with norbuprenorphine-glucuronide in sublingual patients. These data suggest that currently available urine drug tests for buprenorphine, including the more expensive LC-MS/MS based assays, may not be sufficiently sensitive to detect the metabolites from transdermal buprenorphine patients. This study highlights the need to evaluate the value and sensitivity of urine drug tests given the wide range of buprenorphine dosing in clinical practice. These results underscore the need for additional cost benefit analyses comparing different confirmatory drug testing techniques including many commercially available drug testing options. © 2014 Wiley Periodicals, Inc. Wiley Periodicals, Inc.

  15. Urinary free cortisol and cortisone excretion in healthy individuals: influence of water loading.

    PubMed

    Fenske, Martin

    2006-11-01

    The influence of water loading on urinary excretion of free cortisol and cortisone was investigated in healthy men. The results were as follows: water loading tests (intake of 0.25-1.5 L) in a single individual showed that a water load of 1.5 L reliably increased the excretion of urine, free cortisol and cortisone (p < 0.01). Regression analyses gave significant correlations of urine volume with free cortisol and free cortisone, and of free cortisol and free cortisone. Corresponding results were obtained when water loading tests were performed in males who ingested 1.5 L of water (n = 8): the excretion of urine, free cortisol and free cortisone were significantly augmented; correlated was urine volume with free cortisol and free cortisone, and free cortisol with free cortisone. In a third set of tests, volunteers collected one 5 h urine (10:00-15:00 h) after the intake of 3 x 0.1 or 0.5 L at 11:00, 12:00 and 14:00 h. Excretion of urine, free cortisol and free cortisone in males of the low water loading group (3 x 0.1 L) was 0.59 mL/min, and 8.2 or 15.0 microg/5 h; corresponding values in individuals ingesting 3 x 0.5 L of water were 1.5 mL/min (p < 0.01), 12.3 microg/5 h (p > 0.05) and 26.3 microg/5 h (p < 0.02). In summary, urinary free cortisol and cortisone excretion in healthy men depends on urine volume, especially during water diuresis. Thus, interpretation of free cortisol and especially of free cortisone excretion is only possible if subjects strictly control their fluid intake and if urine volume is considered an important pre-analytical parameter-otherwise, interpretation of urinary free cortisol results is difficult and of urinary free cortisone data remains tenuous at best.

  16. Power of Orbitrap-based LC-high resolution-MS/MS for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MSn or GC-MS procedures.

    PubMed

    Michely, Julian A; Meyer, Markus R; Maurer, Hans H

    2018-01-01

    Reliable, sensitive, and comprehensive urine screening procedures by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS) with low or high resolution (HR) are of high importance for drug testing, adherence monitoring, or detection of toxic compounds. Besides conventional urine sampling, dried urine spots are of increasing interest. In the present study, the power of LC-HR-MS/MS was investigated for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MS n or GC-MS procedures. Authentic human urine samples (n = 103) were split in 4 parts. One aliquot was prepared by precipitation (UP), one by UP with conjugate cleavage (UglucP), one spot on filter paper cards and prepared by on-spot cleavage followed by liquid extraction (DUSglucE), and one worked-up by acid hydrolysis, liquid-liquid extraction, and acetylation for GC-MS analysis. The 3 series of LC-HR-MS/MS results were compared among themselves, to corresponding published LC-MS n data, and to screening results obtained by conventional GC-MS. The reference libraries used for the 3 techniques contained over 4500 spectra of parent compounds and their metabolites. The number of all detected hits (770 drug intakes) was set to 100%. The LC-HR-MS/MS approach detected 80% of the hits after UP, 89% after UglucP, and 77% after DUSglucE, which meant over one-third more hits in comparison to the corresponding published LC-MS n results with ≤49% detected hits. The GC-MS approach identified 56% of all detected hits. In conclusion, LC-HR-MS/MS provided the best screening results after conjugate cleavage and precipitation. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Value of Routine Dengue Diagnostic Tests in Urine and Saliva Specimens

    PubMed Central

    Andries, Anne-Claire; Duong, Veasna; Ly, Sowath; Cappelle, Julien; Kim, Kim Srorn; Lorn Try, Patrich; Ros, Sopheaktra; Ong, Sivuth; Huy, Rekol; Horwood, Paul; Flamand, Marie; Sakuntabhai, Anavaj; Tarantola, Arnaud; Buchy, Philippe

    2015-01-01

    Background Dengue laboratory diagnosis is essentially based on detection of the virus, its components or antibodies directed against the virus in blood samples. Blood, however, may be difficult to draw in some patients, especially in children, and sampling during outbreak investigations or epidemiological studies may face logistical challenges or limited compliance to invasive procedures from subjects. The aim of this study was to assess the possibility of using saliva and urine samples instead of blood for dengue diagnosis. Methodology/Principal Findings Serial plasma, urine and saliva samples were collected at several time-points between the day of admission to hospital until three months after the onset of fever in children with confirmed dengue disease. Quantitative RT-PCR, NS1 antigen capture and ELISA serology for anti-DENV antibody (IgG, IgM and IgA) detection were performed in parallel on the three body fluids. RT-PCR and NS1 tests demonstrated an overall sensitivity of 85.4%/63.4%, 41.6%/14.5% and 39%/28.3%, in plasma, urine and saliva specimens, respectively. When urine and saliva samples were collected at the same time-points and tested concurrently, the diagnostic sensitivity of RNA and NS1 detection assays was 69.1% and 34.4%, respectively. IgG/IgA detection assays had an overall sensitivity of 54.4%/37.4%, 38.5%/26.8% and 52.9%/28.6% in plasma, urine and saliva specimens, respectively. IgM were detected in 38.1% and 36% of the plasma and saliva samples but never in urine. Conclusions Although the performances of the different diagnostic methods were not as good in saliva and urine as in plasma specimens, the results obtained by qRT-PCR and by anti-DENV antibody ELISA could well justify the use of these two body fluids to detect dengue infection in situations when the collection of blood specimens is not possible. PMID:26406240

  18. Urine Culture Testing in Community Nursing Homes: Gateway to Antibiotic Overprescribing.

    PubMed

    Sloane, Philip D; Kistler, Christine E; Reed, David; Weber, David J; Ward, Kimberly; Zimmerman, Sheryl

    2017-05-01

    OBJECTIVE To describe current practice around urine testing and identify factors leading to overtreatment of asymptomatic bacteriuria in community nursing homes (NHs) DESIGN Observational study of a stratified random sample of NH patients who had urine cultures ordered in NHs within a 1-month study period SETTING 31 NHs in North Carolina PARTICIPANTS 254 NH residents who had a urine culture ordered within the 1-month study period METHODS We conducted an NH record audit of clinical and laboratory information during the 2 days before and 7 days after a urine culture was ordered. We compared these results with the urine antibiogram from the 31 NHs. RESULTS Empirical treatment was started in 30% of cases. When cultures were reported, previously untreated cases received antibiotics 89% of the time for colony counts of ≥100,000 CFU/mL and in 35% of cases with colony counts of 10,000-99,000 CFU/mL. Due to the high rate of prescribing when culture results returned, 74% of these patients ultimately received a full course of antibiotics. Treated and untreated patients did not significantly differ in temperature, frequency of urinary signs and symptoms, or presence of Loeb criteria for antibiotic initiation. Factors most commonly associated with urine culture ordering were acute mental status changes (32%); change in the urine color, odor, or sediment (17%); and dysuria (15%). CONCLUSIONS Urine cultures play a significant role in antibiotic overprescribing. Antibiotic stewardship efforts in NHs should include reduction in culture ordering for factors not associated with infection-related morbidity as well as more scrutiny of patient condition when results become available. Infect Control Hosp Epidemiol 2017;38:524-531.

  19. Increased dietary long-chain polyunsaturated fatty acids alter serum fatty acid concentrations and lower risk of urine stone formation in cats.

    PubMed

    Hall, Jean A; Brockman, Jeff A; Davidson, Stephen J; MacLeay, Jen M; Jewell, Dennis E

    2017-01-01

    The lifespan of cats with non-obstructive kidney stones is shortened compared with healthy cats indicating a need to reduce stone formation and minimize chronic kidney disease. The purpose of this study was to investigate the effects of increasing dietary polyunsaturated fatty acids (PUFA) on urine characteristics. Domestic-short-hair cats (n = 12; mean age 5.6 years) were randomized into two groups and fed one of two dry-cat foods in a cross-over study design. For one week before study initiation, all cats consumed control food that contained 0.07% arachidonic acid (AA), but no eicosapentaenoic acid (EPA) or docosahexaenoic acid (DHA). Group 1 continued eating control food for 56 days. Group 2 was fed test food for 56 days, which was control food plus fish oil and high-AA oil. Test food contained 0.17% AA, 0.09% EPA and 0.18% DHA. After 56 days, cats were fed the opposite food for another 56 days. At baseline and after each feeding period, serum was analyzed for fatty acid concentrations, and urine for specific gravity, calcium concentration, relative-super-saturation for struvite crystals, and a calcium-oxalate-titrimetric test was performed. After consuming test food, cats had increased (all P<0.001) serum concentrations of EPA (173%), DHA (61%), and AA (35%); decreased urine specific gravity (P = 0.02); decreased urine calcium concentration (P = 0.06); decreased relative-super-saturation for struvite crystals (P = 0.03); and increased resistance to oxalate crystal formation (P = 0.06) compared with cats consuming control food. Oxalate crystal formation was correlated with serum calcium concentration (r = 0.41; P<0.01). These data show benefits for reducing urine stone formation in cats by increasing dietary PUFA.

  20. Increased dietary long-chain polyunsaturated fatty acids alter serum fatty acid concentrations and lower risk of urine stone formation in cats

    PubMed Central

    Brockman, Jeff A.; Davidson, Stephen J.; MacLeay, Jen M.; Jewell, Dennis E.

    2017-01-01

    The lifespan of cats with non-obstructive kidney stones is shortened compared with healthy cats indicating a need to reduce stone formation and minimize chronic kidney disease. The purpose of this study was to investigate the effects of increasing dietary polyunsaturated fatty acids (PUFA) on urine characteristics. Domestic-short-hair cats (n = 12; mean age 5.6 years) were randomized into two groups and fed one of two dry-cat foods in a cross-over study design. For one week before study initiation, all cats consumed control food that contained 0.07% arachidonic acid (AA), but no eicosapentaenoic acid (EPA) or docosahexaenoic acid (DHA). Group 1 continued eating control food for 56 days. Group 2 was fed test food for 56 days, which was control food plus fish oil and high-AA oil. Test food contained 0.17% AA, 0.09% EPA and 0.18% DHA. After 56 days, cats were fed the opposite food for another 56 days. At baseline and after each feeding period, serum was analyzed for fatty acid concentrations, and urine for specific gravity, calcium concentration, relative-super-saturation for struvite crystals, and a calcium-oxalate-titrimetric test was performed. After consuming test food, cats had increased (all P<0.001) serum concentrations of EPA (173%), DHA (61%), and AA (35%); decreased urine specific gravity (P = 0.02); decreased urine calcium concentration (P = 0.06); decreased relative-super-saturation for struvite crystals (P = 0.03); and increased resistance to oxalate crystal formation (P = 0.06) compared with cats consuming control food. Oxalate crystal formation was correlated with serum calcium concentration (r = 0.41; P<0.01). These data show benefits for reducing urine stone formation in cats by increasing dietary PUFA. PMID:29073223

Top