Is a pre-analytical process for urinalysis required?
Petit, Morgane; Beaudeux, Jean-Louis; Majoux, Sandrine; Hennequin, Carole
2017-10-01
For the reliable urinary measurement of calcium, phosphate and uric acid, a pre-analytical process by adding acid or base to urine samples at laboratory is recommended in order to dissolve precipitated solutes. Several studies on different kind of samples and analysers have previously shown that a such pre-analytical treatment is useless. The objective was to study the necessity of pre-analytical treatment of urine on samples collected using the V-Monovette ® (Sarstedt) system and measured on the analyser Architect C16000 (Abbott Diagnostics). Sixty urinary samples of hospitalized patients were selected (n=30 for calcium and phosphate, and n=30 for uric acid). After acidification of urine samples for measurement of calcium and phosphate, and alkalinisation for measurement of uric acid respectively, differences between results before and after the pre-analytical treatment were compared to acceptable limits recommended by the French society of clinical biology (SFBC). No difference in concentration between before and after pre-analytical treatment of urine samples exceeded acceptable limits from SFBC for measurement of calcium and uric acid. For phosphate, only one sample exceeded these acceptable limits, showing a result paradoxically lower after acidification. In conclusion, in agreement with previous study, our results show that acidification or alkalinisation of urine samples from 24 h urines or from urination is not a pre-analytical necessity for measurement of calcium, phosphate and uric acid.
NHEXAS PHASE I MARYLAND STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS
The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 9 pesticides in 345 urine samples over 79 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning ...
NHEXAS PHASE I ARIZONA STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS
The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 4 pesticide metabolites in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. ...
NHEXAS PHASE I ARIZONA STUDY--METALS IN URINE ANALYTICAL RESULTS
The Metals in Urine data set contains analytical results for measurements of up to 6 metals in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sample consists of the fir...
NHEXAS PHASE I MARYLAND STUDY--METALS IN URINE ANALYTICAL RESULTS
The Metals in Urine data set contains analytical results for measurements of up to 3 metals in 376 urine samples over 80 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning void of either Day ...
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN URINE ANALYTICAL RESULTS
The Metals in Urine data set contains analytical results for measurements of up to 7 metals in 86 urine samples over 86 households. Each sample was collected from the primary respondent within each household. The sample consists of the first morning void following the 24-hour d...
Stability studies of amphetamine and ephedrine derivatives in urine.
Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R
2006-10-20
Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.
Adulterants in Urine Drug Testing.
Fu, S
Urine drug testing plays an important role in monitoring licit and illicit drug use for both medico-legal and clinical purposes. One of the major challenges of urine drug testing is adulteration, a practice involving manipulation of a urine specimen with chemical adulterants to produce a false negative test result. This problem is compounded by the number of easily obtained chemicals that can effectively adulterate a urine specimen. Common adulterants include some household chemicals such as hypochlorite bleach, laundry detergent, table salt, and toilet bowl cleaner and many commercial products such as UrinAid (glutaraldehyde), Stealth® (containing peroxidase and peroxide), Urine Luck (pyridinium chlorochromate, PCC), and Klear® (potassium nitrite) available through the Internet. These adulterants can invalidate a screening test result, a confirmatory test result, or both. To counteract urine adulteration, drug testing laboratories have developed a number of analytical methods to detect adulterants in a urine specimen. While these methods are useful in detecting urine adulteration when such activities are suspected, they do not reveal what types of drugs are being concealed. This is particularly the case when oxidizing urine adulterants are involved as these oxidants are capable of destroying drugs and their metabolites in urine, rendering the drug analytes undetectable by any testing technology. One promising approach to address this current limitation has been the use of unique oxidation products formed from reaction of drug analytes with oxidizing adulterants as markers for monitoring drug misuse and urine adulteration. This novel approach will ultimately improve the effectiveness of the current urine drug testing programs. © 2016 Elsevier Inc. All rights reserved.
Li, Wenkui; Luo, Suyi; Smith, Harold T; Tse, Francis L S
2010-02-15
Analyte loss due to non-specific binding, especially container surface adsorption, is not uncommon in the quantitative analysis of urine samples. In developing a sensitive LC-MS/MS method for the determination of a drug candidate, BAF312, in human urine, a simple procedure was outlined for identification, confirmation and prevention of analyte non-specific binding to a container surface and to recover the 'non-specific loss' of an analyte, if no transfer has occurred to the original urine samples. Non-specific binding or container surface adsorption can be quickly identified by using freshly spiked urine calibration standards and pre-pooled QC samples during a LC-MS/MS feasibility run. The resulting low recovery of an analyte in urine samples can be prevented through the use of additives, such as the non-ionic surfactant Tween-80, CHAPS and others, to the container prior to urine sample collection. If the urine samples have not been transferred from the bulk container, the 'non-specific binding' of an analyte to the container surface can be reversed by the addition of a specified amount of CHAPS, Tween-80 or bovine serum albumin, followed by appropriate mixing. Among the above agents, Tween-80 is the most cost-effective. beta-cyclodextrin may be suitable in stabilizing the analyte of interest in urine via pre-treating the matrix with the agent. However, post-addition of beta-cyclodextrin to untreated urine samples does not recover the 'lost' analyte due to non-specific binding or container surface adsorption. In the case of BAF312, a dynamic range of 0.0200-20.0 ng/ml in human urine was validated with an overall accuracy and precision for QC sample results ranging from -3.2 to 5.1% (bias) and 3.9 to 10.2% (CV), respectively. Pre- and post-addition of 0.5% (v/v) Tween-80 to the container provided excellent overall analyte recovery and minimal MS signal suppression when a liquid-liquid extraction in combination with an isocratic LC separation was employed. The compound was stable in 0.5% Tween-80 treated human urine QC samples for at least 24 h at room temperature, after three freeze/thaw cycles with storage at < or =-60 degrees C and for at least 3 months when stored at < or =-60 degrees C. The current work could serve as a simple example in trouble shooting non-specific binding or container surface adsorption in quantitative analysis of urine samples. Copyright 2010. Published by Elsevier B.V.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS
The Pesticide Metabolites in Urine data set contains the analytical results for measurements of up to 8 pesticide metabolites in 86 samples over 86 households. Each sample was collected form the primary respondent within each household. The sample consists of the first morning ...
Doggui, Radhouene; El Ati-Hellal, Myriam; Traissac, Pierre; El Ati, Jalila
2018-03-26
Urinary iodine concentration (UIC) is commonly used to assess iodine status of subjects in epidemiological surveys. As pre-analytical factors are an important source of measurement error and studies about this phase are scarce, our objective was to assess the influence of urine sampling conditions on UIC, i.e., whether the child ate breakfast or not, urine void rank of the day, and time span between last meal and urine collection. A nationwide, two-stage, stratified, cross-sectional study including 1560 children (6-12 years) was performed in 2012. UIC was determined by the Sandell-Kolthoff method. Pre-analytical factors were assessed from children's mothers by using a questionnaire. Association between iodine status and pre-analytical factors were adjusted for one another and socio-economic characteristics by multivariate linear and multinomial regression models (RPR: relative prevalence ratios). Skipping breakfast prior to morning urine sampling decreased UIC by 40 to 50 μg/L and the proportion of UIC < 100 μg/L was higher among children having those skipped breakfast (RPR = 3.2[1.0-10.4]). In unadjusted analyses, UIC was less among children sampled more than 5 h from their last meal. UIC decreased with rank of urine void (e.g., first vs. second, P < 0.001); also, the proportion of UIC < 100 μg/L was greater among 4th rank samples (vs. second RPR = 2.1[1.1-4.0]). Subjects' breakfast status and urine void rank should be accounted for when assessing iodine status. Providing recommendations to standardize pre-analytical factors is a key step toward improving accuracy and comparability of survey results for assessing iodine status from spot urine samples. These recommendations have to be evaluated by future research.
NASA Astrophysics Data System (ADS)
Wu, Peng; Zhang, Yunchang; Lv, Yi; Hou, Xiandeng
2006-12-01
A simple, low cost and highly sensitive method based on cloud point extraction (CPE) for separation/preconcentration and thermospray flame quartz furnace atomic absorption spectrometry was proposed for the determination of ultratrace cadmium in water and urine samples. The analytical procedure involved the formation of analyte-entrapped surfactant micelles by mixing the analyte solution with an ammonium pyrrolidinedithiocarbamate (APDC) solution and a Triton X-114 solution. When the temperature of the system was higher than the cloud point of Triton X-114, the complex of cadmium-PDC entered the surfactant-rich phase and thus separation of the analyte from the matrix was achieved. Under optimal chemical and instrumental conditions, the limit of detection was 0.04 μg/L for cadmium with a sample volume of 10 mL. The analytical results of cadmium in water and urine samples agreed well with those by ICP-MS.
Calvano, C D; Aresta, A; Iacovone, M; De Benedetto, G E; Zambonin, C G; Battaglia, M; Ditonno, P; Rutigliano, M; Bettocchi, C
2010-03-11
Protein analysis in biological fluids, such as urine, by means of mass spectrometry (MS) still suffers for insufficient standardization in protocols for sample collection, storage and preparation. In this work, the influence of these variables on healthy donors human urine protein profiling performed by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was studied. A screening of various urine sample pre-treatment procedures and different sample deposition approaches on the MALDI target was performed. The influence of urine samples storage time and temperature on spectral profiles was evaluated by means of principal component analysis (PCA). The whole optimized procedure was eventually applied to the MALDI-TOF-MS analysis of human urine samples taken from prostate cancer patients. The best results in terms of detected ions number and abundance in the MS spectra were obtained by using home-made microcolumns packed with hydrophilic-lipophilic balance (HLB) resin as sample pre-treatment method; this procedure was also less expensive and suitable for high throughput analyses. Afterwards, the spin coating approach for sample deposition on the MALDI target plate was optimized, obtaining homogenous and reproducible spots. Then, PCA indicated that low storage temperatures of acidified and centrifuged samples, together with short handling time, allowed to obtain reproducible profiles without artifacts contribution due to experimental conditions. Finally, interesting differences were found by comparing the MALDI-TOF-MS protein profiles of pooled urine samples of healthy donors and prostate cancer patients. The results showed that analytical and pre-analytical variables are crucial for the success of urine analysis, to obtain meaningful and reproducible data, even if the intra-patient variability is very difficult to avoid. It has been proven how pooled urine samples can be an interesting way to make easier the comparison between healthy and pathological samples and to individuate possible differences in the protein expression between the two sets of samples. Copyright 2009 Elsevier B.V. All rights reserved.
Remer, Thomas; Montenegro-Bethancourt, Gabriela; Shi, Lijie
2014-12-01
To examine the long-term stability and validity of analyte concentrations of 21 clinical biochemistry parameters in 24-h urine samples stored for 12 or 15 yr at -22°C and preservative free. Healthy children's 24-h urine samples in which the respective analytes had been measured shortly after sample collection (baseline) were reanalyzed. Second measurement was performed after 12 yr (organic acids) and 15 yr (creatinine, urea, osmolality, iodine, nitrogen, anions, cations, acid-base parameters) with the same analytical methodology. Paired comparisons and correlations between the baseline and repeated measurements were done. Recovery rates were calculated. More than half of the analytes (creatinine, urea, iodine, nitrogen, sodium, potassium, magnesium, calcium, ammonium, bicarbonate, citric & uric acid) showed measurement values after >10 yr of storage not significantly different from baseline. 15 of the 21 parameters were highly correlated (r=0.99) between baseline and second measurement. Poorest correlation was r=0.77 for oxalate. Recovery ranged from 73% (oxalate) to 105% (phosphate). Our results suggest high long-term stability and measurement validity for numerous clinical chemistry parameters stored at -22°C without addition of any urine preservative. Prospective storage of urine aliquots at -22°C for periods even exceeding 10 yr, appears to be an acceptable and valid tool in epidemiological settings for later quantification of several urine analytes. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Fan, S; Zou, J H; Miao, H; Zhao, Y F; Chen, H J; Zhao, R; Wu, Y N
2013-01-01
A liquid chromatography-linear ion-trap spectrometry (LC-MS³) method using β-receptor molecular-imprinted polymer (MIP) solid-phase extraction (SPE) as clean-up was developed to determine simultaneously and confirmatively residues of 25 β₂-agonists and 21 β-blockers in urine samples. Urine samples were subjected to enzymatic hydrolysis by β-glucoronidase/arylsulphatase, and then extracted with perchloric acid. Sample clean-up was performed using β-receptor MIP SPE. A Supelco Ascentis® express Rp-Amide column was used to separate the analytes, and MS³ detection used an electrospray ionisation source in positive-ion mode. Recovery studies were carried out using blank urine samples fortified with the 46 analytes at the levels of 0.5, 1.0 and 2.0 μg l⁻¹. Recoveries were obtained ranging from 60.1% to 109.9% with relative standard deviations (RSDs, n = 7) from 0.5% to 19.4%. The limits of detection (LODs) and limits of quantitation (LOQs) of the 46 analytes in urine were 0.02-0.18 and 0.05-0.60 μg l⁻¹, respectively. As a result of the selective clean-up by MIP SPE and MS³ detection of the target drugs, the sensitivity and accuracy of the present method was high enough for monitoring β₂-agonist and β-blocker residues in urine samples. Satisfactory results were obtained in the process of the determination of positive urine samples.
García-Blanco, Ana; Peña-Bautista, Carmen; Oger, Camille; Vigor, Claire; Galano, Jean-Marie; Durand, Thierry; Martín-Ibáñez, Nuria; Baquero, Miguel; Vento, Máximo; Cháfer-Pericás, Consuelo
2018-07-01
Lipid peroxidation plays an important role in Alzheimer Disease, so corresponding metabolites found in urine samples could be potential biomarkers. The aim of this work is to develop a reliable ultra-performance liquid chromatography-tandem mass spectrometry analytical method to determine a new set of lipid peroxidation compounds in urine samples. Excellent sensitivity was achieved with limits of detection between 0.08 and 17 nmol L -1 , which renders this method suitable to monitor analytes concentrations in real samples. The method's precision was satisfactory with coefficients of variation around 5-17% (intra-day) and 8-19% (inter-day). The accuracy of the method was assessed by analysis of spiked urine samples obtaining recoveries between 70% and 120% for most of the analytes. The utility of the described method was tested by analyzing urine samples from patients early diagnosed with mild cognitive impairment or mild dementia Alzheimer Disease following the clinical standard criteria. As preliminary results, some analytes (17(RS)-10-epi-SC-Δ 15 -11-dihomo-IsoF, PGE 2 ) and total parameters (Neuroprostanes, Isoprostanes, Isofurans) show differences between the control and the clinical groups. So, these analytes could be potential early Alzheimer Disease biomarkers assessing the patients' pro-oxidant condition. Copyright © 2018 Elsevier B.V. All rights reserved.
Wan, Lingzhong; Zhu, Haijing; Guan, Yafeng; Huang, Guangming
2017-07-01
A rapid and facile analytical method for quantification of ribonucleosides in human urine was developed by the combination of nanocoating cellulose paper based microextraction and nanoelectrospray ionization-tandem mass spectrometry (nESI-MS/MS). Cellulose paper used for microextraction was modified by nano-precision deposition of uniform ultrathin zirconia gel film using a sol-gel process. Due to the large surface area of the cellulose paper and the strong affinity between zirconia and the cis-diol compounds, the target analytes were selectively extracted from the complex matrix. Thus, the detection sensitivity was greatly improved. Typically, the nanocoating cellulose paper was immersed into the diluted urine for selective extraction of target analytes, then the extracted analytes were subjected to nESI-MS/MS detection. The whole analytical procedure could be completed within 10min. The method was evaluated by the determination of ribonucleosides (adenosine, cytidine, uridine, guanosine) in urine sample. The signal intensities of the ribonuclesides extracted by the nanocoating cellulose paper were greatly enhanced by 136-459-folds compared with the one of the unmodified cellulose paper based microextraction. The limits of detection (LODs) and the limits of quantification (LOQs) of the four ribonucleosides were in the range of 0.0136-1.258μgL -1 and 0.0454-4.194μgL -1 , respectively. The recoveries of the target nucleosides from spiked human urine were in the range of 75.64-103.49% with the relative standard deviations (RSDs) less than 9.36%. The results demonstrate the potential of the proposed method for rapid and facile determination of endogenous ribonucleosides in urine sample. Copyright © 2017. Published by Elsevier B.V.
McMillin, Gwendolyn A; Marin, Stephanie J; Johnson-Davis, Kamisha L; Lawlor, Bryan G; Strathmann, Frederick G
2015-02-01
The major objective of this research was to propose a simplified approach for the evaluation of medication adherence in chronic pain management patients, using liquid chromatography time-of-flight (TOF) mass spectrometry, performed in parallel with select homogeneous enzyme immunoassays (HEIAs). We called it a "hybrid" approach to urine drug testing. The hybrid approach was defined based on anticipated positivity rates, availability of commercial reagents for HEIAs, and assay performance, particularly analytical sensitivity and specificity for drug(s) of interest. Subsequent to implementation of the hybrid approach, time to result was compared with that observed with other urine drug testing approaches. Opioids, benzodiazepines, zolpidem, amphetamine-like stimulants, and methylphenidate metabolite were detected by TOF mass spectrometry to maximize specificity and sensitivity of these 37 drug analytes. Barbiturates, cannabinoid metabolite, carisoprodol, cocaine metabolite, ethyl glucuronide, methadone, phencyclidine, propoxyphene, and tramadol were detected by HEIAs that performed adequately and/or for which positivity rates were very low. Time to result was significantly reduced compared with the traditional approach. The hybrid approach to urine drug testing provides a simplified and analytically specific testing process that minimizes the need for secondary confirmation. Copyright© by the American Society for Clinical Pathology.
NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKES
This data set includes analytical results for measurements of metals in 49 field control samples (spikes). Measurements were made for up to 11 metals in samples of water, blood, and urine. Field controls were used to assess recovery of target analytes from a sample media during s...
Rational use and interpretation of urine drug testing in chronic opioid therapy.
Reisfield, Gary M; Salazar, Elaine; Bertholf, Roger L
2007-01-01
Urine drug testing (UDT) has become an essential feature of pain management, as physicians seek to verify adherence to prescribed opioid regimens and to detect the use of illicit or unauthorized licit drugs. Results of urine drug tests have important consequences in regard to therapeutic decisions and the trust between physician and patient. However, reliance on UDT to confirm adherence can be problematic if the results are not interpreted correctly, and evidence suggests that many physicians lack an adequate understanding of the complexities of UDT and the factors that can affect test results. These factors include metabolic conversion between drugs, genetic variations in drug metabolism, the sensitivity and specificity of the analytical method for a particular drug or metabolite, and the effects of intentional and unintentional interferants. In this review, we focus on the technical features and limitations of analytical methods used for detecting drugs or their metabolites in urine, the statistical constructs that are pertinent to ordering UDT and interpreting test results, and the application of these concepts to the clinical monitoring of patients maintained on chronic opioid therapy.
Gasparini, Mara; Assini, Walter; Bozzoni, Eros; Tognoli, Nadia; Dusi, Guglielmo
2007-03-14
Natural occurrence or illegal treatment of boldenone (BOLD) presence in cattle urine is under debate within the European Union. Separation of conjugated and unconjugated forms of 17alpha-boldenone (alpha-BOLD) and 17beta-boldenone (beta-BOLD) and presence of related molecules as androsta-1,4-diene-3,17-dione (ADD) appear critical points for the decision of an illegal use. The aim of this study is a new analytical approach of BOLD and ADD confirmation in cattle urine. The separation between conjugated and unconjugated forms of BOLD was obtained by a preliminary urine liquid-liquid extraction step with ethyl acetate. In this step the organic phase extracts only unconjugated BOLD and ADD, while BOLD in conjugated form remain in urine phase. Afterwards the urine phase, contains conjugated BOLD, was subjected to an enzymatic deconjugation. Solid-phase extraction (OASIS-HLB Waters) was used for the purification and concentration of analytes in organic and urine phases and liquid chromatography ion electrospray tandem mass spectrometry (LC-MS-MS) was applied for the confirmation of BOLD and ADD, using deuterium-labelled 17beta-boldenone (BOLD-d3) as internal standard. The method was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/CE. The results obtained demonstrate that the developed method show very high specificity, precision, trueness and ruggedness. Decision limits (CCalpha) smaller than 0.5 ng mL(-1) were obtained for each analyte.
Evaluation of FUS-2000 urine analyzer: analytical properties and particle recognition.
Beňovská, Miroslava; Wiewiorka, Ondřej; Pinkavová, Jana
This study evaluates the performance of microscopic part of a hybrid analyzer FUS-2000 (Dirui Industrial Co., Changchun, China), its analytical properties and particle recognition. The evaluation of trueness, repeatability, detection limit, carry-over, linearity range and analytical stability was performed according to Dirui protocol guidelines designed by Dirui Company to guarantee the quality of the instrument. Trueness for low, medium and high-value concentrations was calculated with bias of 15.5, 4.7 and -6.6%, respectively. Detection limit of 5 Ery/μl was confirmed. Coefficient of variation of 11.0, 5.2 and 3.8% was measured for within-run repeatability of low, medium and high concentration. Between-run repeatability for daily quality control had coefficient of variation of 3.0%. Carry-over did not exceed 0.05%. Linearity was confirmed for range of 0-16,000 particles/μl (R 2 = 0.9997). The analytical stability had coefficient of variation of 4.3%. Out of 1258 analyzed urine samples, 362 positive were subjected to light microscopy urine sediment analysis and compared to the analyzer results. Cohen's kappa coefficients were calculated to express the concordance. Squared kappa coefficient was 0.927 (red blood cells), 0.888 (white blood cells), 0.908 (squamous epithelia), 0.634 (transitional epithelia), 0.628 (hyaline casts), 0.843 (granular casts) and 0.623 (bacteria). Single kappa coefficients were 0.885 (yeasts) and 0.756 (crystals), respectively. Aforementioned results show good analytical performance of the analyzer and tight agreement with light microscopy of urine sediment.
FDVIBSPC16: Sheath Flow SERS for Chemical Profiling in Urine
Riordan, Colleen M.; Jacobs, Kevin T.; Negri, Pierre; Schultz, Zachary D.
2016-01-01
The molecular specificity and sensitivity of surface enhanced Raman scattering (SERS) makes it an attractive method for biomedical diagnostics. Here we present results demonstrating the utility and complications for SERS characterization in urine. The chemical fingerprint characteristic of Raman spectra suggests use as a label free diagnostic; however, the complex composition of biological fluids presents a tremendous challenge. In particular, the limited number of surface sites and competing absorption tend to mask the presence of analytes in solution, particularly when the solution contains multiple analytes. To address these problems and characterize biological fluids we have demonstrated a sheath-flow interface for SERS detection. This sheath-flow SERS interface uses hydrodynamic focusing to confine analyte molecules eluting out of a column onto a planar SERS substrate where the molecules are detected by their intrinsic SERS signal. In this report we compare direct detection of benzoylecgonine in urine using DSERS with chemical profiling by capillary zone electrophoresis and sheath-flow SERS detection. The SERS spectrum from the observed migration peaks can identify benzoylecgonine and other distinct spectra are also observed, suggesting improved chemical diagnostics in urine. With over 2000 reported compounds in urine, identification of each of the detected species is an enormous task. Nonetheless, these samples provide a benchmark to establish the potential clinical utility of sheath-flow SERS detection. PMID:27034996
Analytical sensitivity of four commonly used hCG point of care devices.
Kamer, Sandy M; Foley, Kevin F; Schmidt, Robert L; Greene, Dina N
2015-04-01
Point of care (POC) hCG assays are often used to rule-out pregnancy and therefore diagnostic sensitivity, especially at low concentrations of hCG, is important. There are very few studies in the literature that seek to verify the claimed analytical sensitivity of hCG POC devices. The analytical sensitivity of four commonly used hCG POC devices (Alere hCG Combo Cassette, ICON 20 hCG, OSOM hCG Combo Test, and Sure-Vue Serum/Urine hCG-STAT) was challenged using urine samples (n=50) selected based on quantitative hCG concentrations. The majority of these specimens (n=40) had an hCG concentration between 20 and 200 U/L. Each specimen/device combination was reviewed by three individuals. Statistical calculations were performed using Stata 12. The analytical sensitivity of the OSOM was significantly lower inferior than that of the other POC devices. There was no significant difference in the sensitivity of the Alere, ICON 20 and Sure-Vue devices. There was no significant difference in the individual interpretation of the hCG POC results. All hCG POC devices evaluated in this study were susceptible to false negative results at low concentrations of urine hCG. Laboratorians and clinicians should be aware that there are limitations when using urine hCG POC devices to rule out early pregnancy. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Schot, Marjolein J C; van Delft, Sanne; Kooijman-Buiting, Antoinette M J; de Wit, Niek J; Hopstaken, Rogier M
2015-01-01
Objective Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. Setting All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Primary and secondary outcome measures Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. Results The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. Conclusions The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice. PMID:25986635
Kang, Soyoung; Oh, Seung Min; Chung, Kyu Hyuck; Lee, Sooyeun
2014-09-01
γ-Hydroxybutyrate (GHB) is a drug of abuse with a strong anesthetic effect; however, proving its ingestion through the quantification of GHB in biological specimens is not straightforward due to the endogenous presence of GHB in human blood, urine, saliva, etc. In the present study, a surrogate analyte approach was applied to accurate quantitative determination of GHB in human urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in order to overcome this issue. For this, (2)H6-GHB and (13)C2-dl-3-hydroxybutyrate were used as a surrogate standard and as an internal standard, respectively, and parallelism between the surrogate analyte approach and standard addition was investigated at the initial step. The validation results proved the method to be selective, accurate, and precise, with acceptable linearity within calibration ranges (0.1-1μg/ml). The limit of detection and the limit of quantification of (2)H6-GHB were 0.05 and 0.1μg/ml, respectively. No significant variations were observed among urine matrices from different sources. The stability of (2)H6-GHB was satisfactory under sample storage and in-process conditions. However, in vitro production of endogenous GHB was observed when the urine sample was kept under the in-process condition for 4h and under the storage conditions of 4 and -20°C. In order to facilitate the practical interpretation of urinary GHB, endogenous GHB was accurately measured in urine samples from 79 healthy volunteers using the surrogate analyte-based LC-MS/MS method developed in the present study. The unadjusted and creatinine-adjusted GHB concentrations in 74 urine samples with quantitative results ranged from 0.09 to 1.8μg/ml and from 4.5 to 530μg/mmol creatinine, respectively. No significant correlation was observed between the unadjusted and creatinine-adjusted GHB concentrations. The urinary endogenous GHB concentrations were affected by gender and age while they were not significantly influenced by habitual smoking, alcohol drinking, or caffeine-containing beverage drinking. Copyright © 2014 Elsevier B.V. All rights reserved.
Long-term detection of methyltestosterone (ab-) use by a yeast transactivation system.
Wolf, Sylvi; Diel, Patrick; Parr, Maria Kristina; Rataj, Felicitas; Schänzer, Willhelm; Vollmer, Günter; Zierau, Oliver
2011-04-01
The routinely used analytical method for detecting the abuse of anabolic steroids only allows the detection of molecules with known analytical properties. In our supplementary approach to structure-independent detection, substances are identified by their biological activity. In the present study, urines excreted after oral methyltestosterone (MT) administration were analyzed by a yeast androgen screen (YAS). The aim was to trace the excretion of MT or its metabolites in human urine samples and to compare the results with those from the established analytical method. MT and its two major metabolites were tested as pure compounds in the YAS. In a second step, the ability of the YAS to detect MT and its metabolites in urine samples was analyzed. For this purpose, a human volunteer ingested of a single dose of 5 mg methyltestosterone. Urine samples were collected after different time intervals (0-307 h) and were analyzed in the YAS and in parallel by GC/MS. Whereas the YAS was able to trace MT in urine samples at least for 14 days, the detection limits of the GC/MS method allowed follow-up until day six. In conclusion, our results demonstrate that the yeast reporter gene system could detect the activity of anabolic steroids like methyltestosterone with high sensitivity even in urine. Furthermore, the YAS was able to detect MT abuse for a longer period of time than classical GC/MS. Obviously, the system responds to long-lasting metabolites yet unidentified. Therefore, the YAS can be a powerful (pre-) screening tool with the potential that to be used to identify persistent or late screening metabolites of anabolic steroids, which could be used for an enhancement of the sensitivity of GC/MS detection techniques.
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES
The Metals in Spike Samples data set contains the analytical results of measurements of up to 11 metals in 38 control samples (spikes) from 18 households. Measurements were made in spiked samples of dust, food, beverages, blood, urine, and dermal wipe residue. Spiked samples we...
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN BLANK SAMPLES
The Pesticide Metabolites in Blank Samples data set contains the analytical results of measurements of up to 4 pesticide metabolites in 3 blank samples from 3 households. Measurements were made in blank samples of urine. Blank samples were used to assess the potential for sampl...
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDES IN BLANK SAMPLES
The Pesticides in Blank Samples data set contains the analytical results of measurements of up to 4 pesticides in 43 blank samples from 29 households. Measurements were made in blank samples of dust, indoor and outdoor air, food and beverages, blood, urine, and dermal wipe resid...
NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANKS
The Metals in Blanks data set contains the analytical results of measurements of up to 11 metals in 115 blank samples from 58 households. Measurements were made in blank samples of indoor and outdoor air, drinking water, beverages, urine, and blood. Blank samples were used to a...
NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN REPLICATES
This data set includes analytical results for measurements of metals in 490 duplicate (replicate) samples and for particles in 130 duplicate samples. Measurements were made for up to 11 metals in samples of air, dust, water, blood, and urine. Duplicate samples (samples collected ...
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN SPIKE SAMPLES
The Pesticide Metabolites in Spike Samples data set contains the analytical results of measurements of up to 4 pesticide metabolites in 3 control samples (spikes) from 3 households. Measurements were made in spiked samples of urine. Spiked samples were used to assess recovery o...
NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN BLANKS
The Pesticide Metabolites in Blanks data set contains the analytical results of measurements of up to 4 pesticide metabolites in 14 blank samples from 13 households. Measurements were made in blank samples of urine. Blank samples were used to assess the potential for sample con...
Skopp, Gisela; Pötsch, Lucia
2004-01-01
Preanalytical stability of a drug and its major metabolites is an important consideration in pharmacokinetic studies or whenever the analyte pattern is used to estimate drug habits. Firstly, the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH, THCCOOglu) in authentic urine samples was investigated. Random urine samples of cannabis users (n = 38) were stored at -20, 4, and 20 degrees C up to 15 days and up to 5 days at 40 degrees C, and alterations of the analyte pattern during storage were followed by liquid chromatography-tandem mass spectrometry. Secondly, the influence of pH (range 5.0-8.0) on the stability of the analytes was studied using spiked urine to elucidate the results obtained from authentic samples. In authentic urine samples, the initial pH ranged from 5.1 to 8.8. The glucuronide was found to be highly labile at a storage temperature of 4 degrees C and above. Initially, 18 urine samples tested positive for THCCOOH. After 2 days storage at 20 degrees C, THCCOOH was detectable in a further 4 samples, and 7 more samples tested positive for THCCOOH (5-81 ng/mL) after 15 days. Depending on time and temperature, the glucuronide concentration decreased, resulting in an increase of THCCOOH concentration. However, a loss in mean total THCCOOH concentration was found, which was significantly higher in deteriorated samples than in samples without signs of deterioration after 15 days of storage at 20 degrees C. In the drug-free urine sample separately spiked with THCCOOglu or THCCOOH, the investigations on the stability of the target analytes at various pH values revealed that THCCOOH was stable at pH 5.0. At higher pH values, its concentration slightly decreased with time, and about 69% of the initial THCCOOH concentration was still present at pH 8.0 on day 5. THCCOOglu concentrations rapidly decreased with increasing pH value. For example, only 72% of the initial THCCOOglu concentration could be detected at pH 5.0 on day 1. Degradation of the glucuronide resulted in formation of THCCOOH, which was observed even at pH 5.0. In light of the present findings, advanced forensic interpretations based on the presence of THCCOOH or the pattern of THCCOOH and THCCOOglu in stored urine samples seems questionable.
Aramendía, Maite; Rello, Luis; Vanhaecke, Frank; Resano, Martín
2012-10-16
Collection of biological fluids on clinical filter papers shows important advantages from a logistic point of view, although analysis of these specimens is far from straightforward. Concerning urine analysis, and particularly when direct trace elemental analysis by laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) is aimed at, several problems arise, such as lack of sensitivity or different distribution of the analytes on the filter paper, rendering obtaining reliable quantitative results quite difficult. In this paper, a novel approach for urine collection is proposed, which circumvents many of these problems. This methodology consists on the use of precut filter paper discs where large amounts of sample can be retained upon a single deposition. This provides higher amounts of the target analytes and, thus, sufficient sensitivity, and allows addition of an adequate internal standard at the clinical lab prior to analysis, therefore making it suitable for a strategy based on unsupervised sample collection and ulterior analysis at referral centers. On the basis of this sampling methodology, an analytical method was developed for the direct determination of several elements in urine (Be, Bi, Cd, Co, Cu, Ni, Sb, Sn, Tl, Pb, and V) at the low μg L(-1) level by means of LA-ICPMS. The method developed provides good results in terms of accuracy and LODs (≤1 μg L(-1) for most of the analytes tested), with a precision in the range of 15%, fit-for-purpose for clinical control analysis.
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANK SAMPLES
The Metals in Blank Samples data set contains the analytical results of measurements of up to 27 metals in 82 blank samples from 26 households. Measurements were made in blank samples of dust, indoor and outdoor air, personal air, food, beverages, blood, urine, and dermal wipe r...
NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANKS
This data set includes analytical results for measurements of metals in 205 blank samples and for particles in 64 blank samples. Measurements were made for up to 12 metals in blank samples of air, dust, soil, water, food and beverages, blood, hair, and urine. Blank samples were u...
NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES
The Metals in Spikes data set contains the analytical results of measurements of up to 4 metals in 71 control samples (spikes) from 47 households. Measurements were made in samples of indoor and outdoor air, blood, and urine. Controls were used to assess recovery of target anal...
Urine analysis concerning xenon for doping control purposes.
Thevis, Mario; Piper, Thomas; Geyer, Hans; Schaefer, Maximilian S; Schneemann, Julia; Kienbaum, Peter; Schänzer, Wilhelm
2015-01-15
On September 1(st) 2014, a modified Prohibited List as established by the World Anti-Doping Agency (WADA) became effective featuring xenon as a banned substance categorized as hypoxia-inducible factor (HIF) activator. Consequently, the analysis of xenon from commonly provided doping control specimens such as blood and urine is desirable, and first data on the determination of xenon from urine in the context of human sports drug testing, are presented. In accordance to earlier studies utilizing plasma as doping control matrix, urine was enriched to saturation with xenon, sequentially diluted, and the target analyte was detected as supported by the internal standard d6 -cyclohexanone by means of gas chromatography/triple quadrupole mass spectrometry (GC/MS/MS) using headspace injection. Three major xenon isotopes at m/z 128.9, 130.9 and 131.9 were targeted in (pseudo) selected reaction monitoring mode enabling the unambiguous identification of the prohibited substance. Assay characteristics including limit of detection (LOD), intraday/interday precision, and specificity as well as analyte recovery under different storage conditions were determined. Proof-of-concept data were generated by applying the established method to urine samples collected from five patients before, during and after (up to 48 h) xenon-based general anesthesia. Xenon was traceable in enriched human urine samples down to the detection limit of approximately 0.5 nmol/mL. The intraday and interday imprecision values of the method were found below 25%, and specificity was demonstrated by analyzing 20 different blank urine samples that corroborated the fitness-for-purpose of the analytical approach to unequivocally detect xenon at non-physiological concentrations in human urine. The patients' urine specimens returned 'xenon-positive' test results up to 40 h post-anesthesia, indicating the limits of the expected doping control detection window. Since xenon has been considered a prohibited substance according to WADA regulations in September 2014, its analysis from common specimens of routine sports drug testing is desirable. In previous studies, its traceability in whole blood and plasma was shown, and herein a complementary approach utilizing doping control urine samples for the GC/MS/MS analysis of xenon was reported. Copyright © 2014 John Wiley & Sons, Ltd.
Stability of Synthetic Cathinones in Urine.
Glicksberg, Lindsay; Kerrigan, Sarah
2018-03-01
In this report, we evaluate the concentration, pH, temperature and analyte-dependent effects on cathinone stability in preserved human urine. A total of 22 synthetic cathinones were evaluated at 100 ng/mL and 1,000 ng/mL in pH 4 and pH 8 urine over 6 months. Specimens were stored at -20°C, 4°C, 20°C and 32°C. The stability of synthetic cathinones was highly dependent on urine pH and storage temperature. Cathinones were considerably more stable in acidic urine (pH 4) at low temperature. In alkaline urine (pH 8) at 32°C, significant losses (>20%) were observed within hours for the majority of drugs. In contrast, all drugs were stable in frozen and refrigerated urine at pH 4 for the duration of the study. These results highlight the importance of sample storage and the potential for pre-analytical changes in concentration during routine shipping and handling of specimens. Significant structural influence was also observed. Cathinones bearing a tertiary amine (pyrrolidine group) were significantly more stable than their secondary amine counterparts. The methylenedioxy group also exerted a significant stabilizing effect on both the tertiary and secondary amines. In the absence of the methylenedioxy group, no significant differences in stability were observed between the unsubstituted and ring substituted secondary amines. Half-lives at ambient temperature in pH 8 urine ranged from 9 h (3-fluoromethcathinone) to 4.3 months (methylenedioxypyrovalerone and 3,4-methylenedioxy-α-pyrrolidinobutiophenone), demonstrating the importance of analyte dependence, and the dual stabilizing effect of both the pyrollidine and methylenedioxy groups. Biological evidence may be subjected to a variety of environmental conditions prior to, and during transport to the forensic laboratory. These findings demonstrate the inherent instability of certain cathinone species in biological evidence under some conditions. Moreover, this study highlights the need for quantitative drug findings in toxicological investigations to be interpreted cautiously, and within the context of specimen storage and integrity.
Pantano, Flaminia; Brauneis, Stefano; Forneris, Alexandre; Pacifici, Roberta; Marinelli, Enrico; Kyriakou, Chrystalla; Pichini, Simona; Busardò, Francesco Paolo
2017-08-28
Oxycodone is a narcotic drug widely used to alleviate moderate and severe acute and chronic pain. Variability in analgesic efficacy could be explained by inter-subject variations in plasma concentrations of parent drug and its active metabolite, oxymorphone. To evaluate patient compliance and to set up therapeutic drug monitoring (TDM), an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay was developed and validated for the parent drug and its major metabolites noroxycodone and oxymorphone. Extraction of analytes from plasma and urine samples was obtained by simple liquid-liquid extraction. The chromatographic separation was achieved with a reversed phase column using a linear gradient elution with two solvents: acetic acid 1% in water and methanol. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI). Separation of analytes was obtained in less than 5 min. Linear calibration curves for all the analytes under investigation in urine and plasma samples showed determination coefficients (r2) equal or higher than 0.990. Mean absolute analytical recoveries were always above 86%. Intra- and inter-assay precision (measured as coefficient of variation, CV%) and accuracy (measured as % error) values were always better than 13%. Limit of detection at 0.06 and 0.15 ng/mL and limit of quantification at 0.2 and 0.5 ng/mL for plasma and urine samples, respectively, were adequate for the purpose of the present study. Rapid extraction, identification and quantification of oxycodone and its metabolites both in urine and plasma by UHPLC-MS/MS assay was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in patients under oxycodone treatment.
Excretion of endogenous boldione in human urine: influence of phytosterol consumption.
Verheyden, Karolien; Noppe, Herlinde; Vanhaecke, Lynn; Wille, Klaas; Bussche, Julie Vanden; Bekaert, Karen; Thas, Olivier; Janssen, Colin R; De Brabander, Hubert F
2009-10-01
Boldenone (17-hydroxy-androsta-1,4-diene-3-one, Bol) and boldione (androst-1,4-diene-3,17-dione, ADD), are currently listed as exogenous anabolic steroids by the World Anti-Doping Agency. However, it has been reported that these analytes can be produced endogenously. Interestingly, only for Bol a comment is included in the list on its potential endogenous origin. In this study, the endogenous origin of ADD in human urine was investigated, and the potential influence of phytosterol consumption was evaluated. We carried out a 5-week in vivo trial with both men (n=6) and women (n=6) and measured alpha-boldenone, beta-boldenone, boldione, androstenedione, beta-testosterone and alpha-testosterone in their urine using gas chromatography coupled to multiple mass spectrometry (GC-MS-MS). The results demonstrate that endogenous ADD is sporadically produced at concentrations ranging from 0.751 ng mL(-1) to 1.73 ng mL(-1), whereas endogenous Bol could not be proven. We also tested the effect of the daily consumption of a commercially available phytosterol-enriched yogurt drink on the presence of these analytes in human urine. Results from this study could not indicate a relation of ADD-excretion with the consumption of phytosterols at the recommended dose. The correlations between ADD and other steroids were consistently stronger for volunteers consuming phytosterols (test) than for those refraining from phytosterol consumption (control). Excretion of AED, bT and aT did not appear to be dependent on the consumption of phytosterols. This preliminary in vivo trial indicates the endogenous origin of boldione or ADD in human urine, independent on the presence of any structural related analytes such as phytosterols.
Evaluation of the analytical variability of dipstick protein pads in canine urine.
Giraldi, Marco; Paltrinieri, Saverio; Zatelli, Andrea
2018-06-01
The dipstick is a first-line and inexpensive test that can exclude the presence of proteinuria in dogs. However, no information is available about the analytical variability of canine urine dipstick analysis. The aim of this study was to assess the analytical variability in 2 dipsticks and the inter-operator variability in dipstick interpretation. Canine urine supernatants (n = 174) were analyzed with 2 commercially available dipsticks. Two observers evaluated each result blinded to the other observer and to the results of the other dipstick. Intra- and inter-assay variability was assessed in 5 samples (corresponding to the 5 different semi-quantitative results) tested 10 consecutive times over 5 consecutive days. The agreement between observers and between dipsticks was evaluated with Cohen's k test. Intra-assay repeatability was good (≤3/10 errors), whereas inter-assay variability was higher (from 1/5 to 4/5 discordant results). The concordance between the operators (k = 0.68 and 0.79 for the 2 dipsticks) and that of the dipsticks (k = 0.66 and 0.74 for the 2 operators) was good. However, 1 observer and 1 dipstick overestimated the results compared with the second observer or dipstick. In any case, discordant results accounted for a single unit of the semi-quantitative scale. As for any other method, analytic variability may affect the semi-quantitation of urinary proteins when using the dipstick method. Subjective interpretation of the pad and, to a lesser extent, intrinsic staining properties of the pads could affect the results. Further studies are warranted to evaluate the effect of this variability on clinical decisions. © 2018 American Society for Veterinary Clinical Pathology.
The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative
NASA Technical Reports Server (NTRS)
Nillen, Jeannie L.; Smith, Scott M.
2003-01-01
A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.
Stephanson, N N; Signell, P; Helander, A; Beck, O
2017-08-01
The influx of new psychoactive substances (NPS) has created a need for improved methods for drug testing in toxicology laboratories. The aim of this work was to design, validate and apply a multi-analyte liquid chromatography-high-resolution mass spectrometry (LC-HRMS) method for screening of 148 target analytes belonging to the NPS class, plant alkaloids and new psychoactive therapeutic drugs. The analytical method used a fivefold dilution of urine with nine deuterated internal standards and injection of 2 μl. The LC system involved a 2.0 μm 100 × 2.0 mm YMC-UltraHT Hydrosphere-C 18 column and gradient elution with a flow rate of 0.5 ml/min and a total analysis time of 6.0 min. Solvent A consisted of 10 mmol/l ammonium formate and 0.005% formic acid, pH 4.8, and Solvent B was methanol with 10 mmol/l ammonium formate and 0.005% formic acid. The HRMS (Q Exactive, Thermo Scientific) used a heated electrospray interface and was operated in positive mode with 70 000 resolution. The scan range was 100-650 Da, and data for extracted ion chromatograms used ± 10 ppm tolerance. Product ion monitoring was applied for confirmation analysis and for some selected analytes also for screening. Method validation demonstrated limited influence from urine matrix, linear response within the measuring range (typically 0.1-1.0 μg/ml) and acceptable imprecision in quantification (CV <15%). A few analytes were found to be unstable in urine upon storage. The method was successfully applied for routine drug testing of 17 936 unknown samples, of which 2715 (15%) contained 52 of the 148 analytes. It is concluded that the method design based on simple dilution of urine and using LC-HRMS in extracted ion chromatogram mode may offer an analytical system for urine drug testing that fulfils the requirement of a 'black box' solution and can replace immunochemical screening applied on autoanalyzers. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Blood in Urine: MedlinePlus Lab Test Information
... Information → Blood in Urine URL of this page: https://medlineplus.gov/labtests/bloodinurine.html Blood in Urine ... 2017 Mar 14]; [about 4 screens]: Available from: https://labtestsonline.org/understanding/analytes/urinalysis/tab/test Lab ...
Rapid methods for the isolation of actinides Sr, Tc and Po from raw urine.
McAlister, Daniel R; Horwitz, E Philip; Harvey, James T
2011-08-01
Rapid methods for the isolation and analysis of individual actinides (Th, U, Pu, Am/Cm) and Sr, Tc and Po from small volumes of raw urine have been developed. The methods involve acidification of the sample and the addition of aluminum nitrate or aluminum chloride salting-out agent prior to isolation of the desired analyte using a tandem combination of prefilter material and extraction chromatographic resin. The method has been applied to the separation of individual analytes from spiked urine samples. Analytes were recovered in high yield and radionuclide purity with separation times as low as 30 min. The chemistry employed is compatible with automation on the ARSIIe instrument.
Berg, Wolfgang; Bechler, Robin; Laube, Norbert
2009-01-01
Since its first publication in 2000, the BONN-Risk-Index (BRI) has been successfully used to determine the calcium oxalate (CaOx) crystallization risk from urine samples. To date, a BRI-measuring device, the "Urolizer", has been developed, operating automatically and requiring only a minimum of preparation. Two major objectives were pursued: determination of Urolizer precision, and determination of the influence of 24-h urine storage at moderate temperatures on BRI. 24-h urine samples from 52 CaOx stone-formers were collected. A total of 37 urine samples were used for the investigation of Urolizer precision by performing six independent BRI determinations in series. In total, 30 samples were taken for additional investigation of urine storability. Each sample was measured thrice: directly after collection, after 24-h storage at T=21 degrees C, and after 24-h cooling at T=4 degrees C. Outcomes were statistically tested for identity with regard to the immediately obtained results. Repeat measurements for evaluation of Urolizer precision revealed statistical identity of data (p-0.05). 24-h storage of urine at both tested temperatures did not significantly affect BRI (p-0.05). The pilot-run Urolizer shows high analytical reliability. The innovative analysis device may be especially suited for urologists specializing in urolithiasis treatment. The possibility for urine storage at moderate temperatures without loss of analysis quality further demonstrates the applicability of the BRI method.
Xie, Rui; Wen, Jun; Wei, Hua; Fan, Guorong; Zhang, Dabing
2010-05-01
An automated system using on-line solid-phase extraction and HPLC with UV detection was developed for the determination of faropenem in human plasma and urine. Analytical process was performed isocratically with two reversed-phase columns connected by a switching valve. After simple pretreatment for plasma and urine with acetonitrile, a volume of 100microl upper layer of the plasma or urine samples was injected for on-line SPE column switching HPLC-UV analysis. The analytes were retained on the self-made trap column (Lichrospher C(18), 4.6mmx37mm, 25microm) with the loading solvent (20mM NaH(2)PO(4) adjusted pH 3.5) at flow rate of 2mlmin(-1), and most matrix materials were removed from the column to waste. After 0.5min washing, the valve was switched to another position so that the target analytes could be eluted from trap column to analytical column in the back-flush mode by the mobile phase (acetonitrile-20mM NaH(2)PO(4) adjusted pH 3.5, 16:84, v/v) at flow rate of 1.5mlmin(-1), and then separated on the analytical column (Ultimate XB-C(18), 4.6mmx50mm, 5microm).The complete cycle of the on-line SPE preconcentration purification and HPLC separation of the analytes was 5min. Calibration curves with good linearities (r=0.9994 for plasma sample and r=0.9988 for urine sample) were obtained in the range 0.02-5microgml(-1) in plasma and 0.05-10microg ml(-1) in urine for faropenem. The optimized method showed good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. The method was successfully utilized to quantify faropenem in human plasma and urine to support the clinical pharmacokinetic studies. Copyright 2009 Elsevier B.V. All rights reserved.
Otero-Fernández, Mara; Cocho, José Ángel; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2013-06-19
A micro-analytical method based on spotting urine samples (20μL) onto blood/urine spot collection cards followed by air-drying and extraction (dried urine spot, DUS) was developed and validated for the screening/confirmation assay of morphine, 6-methylacetylmorphine (6-MAM), codeine, cocaine and benzoylecgonine (BZE). Acetonitrile (3 mL) was found to be a useful solvent for target extraction from DUSs under an orbital-horizontal stirring at 180 rpm for 10 min. Determinations were performed by direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) under positive electrospray ionization conditions, and by using multiple reaction monitoring (MRM) with one precursor ion/product ion transition for the identification and quantification (deuterated analogs of each target as internal standards) of each analyte. The limits of detection of the method were 0.26, 0.94, 1.5, 1.1, and 2.0 ng mL(-1), for cocaine, BZE, codeine, morphine and 6-MAM, respectively; whereas, relative standard deviations of intra- and inter-day precision were lower than 8 and 11%, respectively, and intra- and inter-day analytical recoveries ranged from 94±4 to 105±3%. The small volume of urine required (20 μL), combined with the simplicity of the analytical technique makes it a useful procedure for screening/quantifying drugs of abuse. The method was successfully applied to the analysis of urine from polydrug abusers. Copyright © 2013 Elsevier B.V. All rights reserved.
Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S
2015-04-01
This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.
Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.
2014-01-01
This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921
Contamination of dried blood spots - an underestimated risk in newborn screening.
Winter, Theresa; Lange, Anja; Hannemann, Anke; Nauck, Matthias; Müller, Cornelia
2018-01-26
Newborn screening (NBS) is an established screening procedure in many countries worldwide, aiming at the early detection of inborn errors of metabolism. For decades, dried blood spots have been the standard specimen for NBS. The procedure of blood collection is well described and standardized and includes many critical pre-analytical steps. We examined the impact of contamination of some anticipated common substances on NBS results obtained from dry spot samples. This possible pre-analytical source of uncertainty has been poorly examined in the past. Capillary blood was obtained from 15 adult volunteers and applied to 10 screening filter papers per volunteer. Nine filter papers were contaminated without visible trace. The contaminants were baby diaper rash cream, baby wet wipes, disinfectant, liquid infant formula, liquid infant formula hypoallergenic (HA), ultrasonic gel, breast milk, feces, and urine. The differences between control and contaminated samples were evaluated for 45 NBS quantities. We estimated if the contaminations might lead to false-positive NBS results. Eight of nine investigated contaminants significantly altered NBS analyte concentrations and potentially caused false-positive screening outcomes. A contamination with feces was most influential, affecting 24 of 45 tested analytes followed by liquid infant formula (HA) and urine, affecting 19 and 13 of 45 analytes, respectively. A contamination of filter paper samples can have a substantial effect on the NBS results. Our results underline the importance of good pre-analytical training to make the staff aware of the threat and ensure reliable screening results.
A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.
Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R
2017-07-01
The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.
Quifer-Rada, Paola; Martínez-Huélamo, Miriam; Lamuela-Raventos, Rosa M
2017-07-19
Phenolic compounds are present in human fluids (plasma and urine) mainly as glucuronidated and sulfated metabolites. Up to now, due to the unavailability of standards, enzymatic hydrolysis has been the method of choice in analytical chemistry to quantify these phase II phenolic metabolites. Enzymatic hydrolysis procedures vary in enzyme concentration, pH and temperature; however, there is a lack of knowledge about the stability of polyphenols in their free form during the process. In this study, we evaluated the stability of 7 phenolic acids, 2 flavonoids and 3 prenylflavanoids in urine during enzymatic hydrolysis to assess the suitability of this analytical procedure, using three different concentrations of β-glucuronidase/sulfatase enzymes from Helix pomatia. The results indicate that enzymatic hydrolysis negatively affected the recovery of the precursor and free-form polyphenols present in the sample. Thus, enzymatic hydrolysis does not seem an ideal analytical strategy to quantify glucuronidated and sulfated polyphenol metabolites.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hawkins, C.; Dietz, M.; Kaminski, M.
2016-03-01
A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial,more » extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.« less
Küme, Tuncay; Sağlam, Barıs; Ergon, Cem; Sisman, Ali Rıza
2018-01-01
The aim of this study is to evaluate and compare the analytical performance characteristics of the two creatinine methods based on the Jaffe and enzymatic methods. Two original creatinine methods, Jaffe and enzymatic, were evaluated on Architect c16000 automated analyzer via limit of detection (LOD) and limit of quantitation (LOQ), linearity, intra-assay and inter-assay precision, and comparability in serum and urine samples. The method comparison and bias estimation using patient samples according to CLSI guideline were performed on 230 serum and 141 urine samples by analyzing on the same auto-analyzer. The LODs were determined as 0.1 mg/dL for both serum methods and as 0.25 and 0.07 mg/dL for the Jaffe and the enzymatic urine method respectively. The LOQs were similar with 0.05 mg/dL value for both serum methods, and enzymatic urine method had a lower LOQ than Jaffe urine method, values at 0.5 and 2 mg/dL respectively. Both methods were linear up to 65 mg/dL for serum and 260 mg/dL for urine. The intra-assay and inter-assay precision data were under desirable levels in both methods. The higher correlations were determined between two methods in serum and urine (r=.9994, r=.9998 respectively). On the other hand, Jaffe method gave the higher creatinine results than enzymatic method, especially at the low concentrations in both serum and urine. Both Jaffe and enzymatic methods were found to meet the analytical performance requirements in routine use. However, enzymatic method was found to have better performance in low creatinine levels. © 2017 Wiley Periodicals, Inc.
Fashi, Armin; Khanban, Fatemeh; Yaftian, Mohammad Reza; Zamani, Abbasali
2017-01-01
A new design of electromembrane microextraction coupled with high-performance liquid chromatography was developed for the determination of Pramipexole as a model analyte in urine samples. The presence of reduced graphene oxide in the membrane and Triton X-114 in the donor phase augments the extraction efficiency of Pramipexole by the proposed method. Dispersed reduced graphene oxide in the organic solvent was held in the pores of the fiber wall by capillary forces and sonication. It is possible that the immobilized reduced graphene oxide acts as a sorbent, affording an additional pathway for analyte transportation. Besides, the presence of Triton X-114 in the donor phase promotes effective migration of ionic analytes across the membrane. The parameters influencing the extraction procedure, such as type and concentration of surfactant, type of organic solvent, amount of reduced graphene oxide, sonication time, applied voltage, extraction time, ionic strength, pH of the donor and acceptor solutions, and stirring rate were optimized. The linear working ranges of the method for preconcentration- determination of Pramipexole in water and urine samples were found to be 0.13-1000 and 0.47-1000ngmL -1 with corresponding detection limits of 0.04 and 0.14ngmL -1 , respectively. The proposed method allows achieving enrichment factors of 301 and 265 for preconcentration of the analyte in water and urine samples, respectively. The method was successfully applied for the determination of Pramipexole in the urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Multi-center evaluation of analytical performance of the Beckman Coulter AU5822 chemistry analyzer.
Zimmerman, M K; Friesen, L R; Nice, A; Vollmer, P A; Dockery, E A; Rankin, J D; Zmuda, K; Wong, S H
2015-09-01
Our three academic institutions, Indiana University, Northwestern Memorial Hospital, and Wake Forest, were among the first in the United States to implement the Beckman Coulter AU5822 series chemistry analyzers. We undertook this post-hoc multi-center study by merging our data to determine performance characteristics and the impact of methodology changes on analyte measurement. We independently completed performance validation studies including precision, linearity/analytical measurement range, method comparison, and reference range verification. Complete data sets were available from at least one institution for 66 analytes with the following groups: 51 from all three institutions, and 15 from 1 or 2 institutions for a total sample size of 12,064. Precision was similar among institutions. Coefficients of variation (CV) were <10% for 97%. Analytes with CVs >10% included direct bilirubin and digoxin. All analytes exhibited linearity over the analytical measurement range. Method comparison data showed slopes between 0.900-1.100 for 87.9% of the analytes. Slopes for amylase, tobramycin and urine amylase were <0.8; the slope for lipase was >1.5, due to known methodology or standardization differences. Consequently, reference ranges of amylase, urine amylase and lipase required only minor or no modification. The four AU5822 analyzers independently evaluated at three sites showed consistent precision, linearity, and correlation results. Since installations, the test results had been well received by clinicians from all three institutions. Copyright © 2015. Published by Elsevier Inc.
Doping control container for urine stabilization: a pilot study.
Tsivou, Maria; Giannadaki, Evangelia; Hooghe, Fiona; Roels, Kris; Van Gansbeke, Wim; Garribba, Flaminia; Lyris, Emmanouil; Deventer, Koen; Mazzarino, Monica; Donati, Francesco; Georgakopoulos, Dimitrios G; Van Eenoo, Peter; Georgakopoulos, Costas G; de la Torre, Xavier; Botrè, Francesco
2017-05-01
Urine collection containers used in the doping control collection procedure do not provide a protective environment for urine, against degradation by microorganisms and proteolytic enzymes. An in-house chemical stabilization mixture was developed to tackle urine degradation problems encountered in human sport samples, in cases of microbial contamination or proteolytic activity. The mixture consists of antimicrobial substances and protease inhibitors for the simultaneous inactivation of a wide range of proteolytic enzymes. It has already been tested in lab-scale, as part of World Anti-Doping Agency's (WADA) funded research project, in terms of efficiency against microbial and proteolytic activity. The present work, funded also by WADA, is a follow-up study on the improvement of chemical stabilization mixture composition, application mode and limitation of interferences, using pilot urine collection containers, spray-coated in their internal surface with the chemical stabilization mixture. Urine in plastic stabilized collection containers have been gone through various incubation cycles to test for stabilization efficiency and analytical matrix interferences by three WADA accredited Laboratories (Athens, Ghent, and Rome). The spray-coated chemical stabilization mixture was tested against microorganism elimination and steroid glucuronide degradation, as well as enzymatic breakdown of proteins, such as intact hCG, recombinant erythropoietin and small peptides (GHRPs, ipamorelin), induced by proteolytic enzymes. Potential analytical interferences, observed in the presence of spray-coated chemical stabilization mixture, were recorded using routine screening procedures. The results of the current study support the application of the spray-coated plastic urine container, in the doping control collection procedure. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola
2011-04-01
(1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.
Mycotoxin Analysis of Human Urine by LC-MS/MS: A Comparative Extraction Study
Escrivá, Laura; Font, Guillermina
2017-01-01
The lower mycotoxin levels detected in urine make the development of sensitive and accurate analytical methods essential. Three extraction methods, namely salting-out liquid–liquid extraction (SALLE), miniQuEChERS (quick, easy, cheap, effective, rugged, and safe), and dispersive liquid–liquid microextraction (DLLME), were evaluated and compared based on analytical parameters for the quantitative LC-MS/MS measurement of 11 mycotoxins (AFB1, AFB2, AFG1, AFG2, OTA, ZEA, BEA, EN A, EN B, EN A1 and EN B1) in human urine. DLLME was selected as the most appropriate methodology, as it produced better validation results for recovery (79–113%), reproducibility (RSDs < 12%), and repeatability (RSDs < 15%) than miniQuEChERS (71–109%, RSDs <14% and <24%, respectively) and SALLE (70–108%, RSDs < 14% and < 24%, respectively). Moreover, the lowest detection (LODS) and quantitation limits (LOQS) were achieved with DLLME (LODs: 0.005–2 μg L−1, LOQs: 0.1–4 μg L−1). DLLME methodology was used for the analysis of 10 real urine samples from healthy volunteers showing the presence of ENs B, B1 and A1 at low concentrations. PMID:29048356
Kusaka, M; Setiabudy, R; Chiba, K; Ishizaki, T
1996-02-01
A simple high-performance liquid chromatographic (HPLC) assay method was developed for the measurement of proguanil (PG) and its major metabolites, cycloguanil (CG) and 4-chlorophenyl-biguanide (CPB), in human plasma and urine. The assay allowed the simultaneous determination of all analytes in 1 ml of plasma or 0.1 ml of urine. The detection limits of PG, CG, and CPB, defined as the signal-to-noise ratio of 3, were 1 and 5 ng/ml for plasma and urine samples, respectively. Recoveries of the analytes and the internal standard (pyrimethamine) were > 62% from plasma and > 77% from urine. Intra-assay and interassay coefficients of variation for all analytes in plasma and urine were < 10% except for the values of CG and CPB, which ranged from 10% to 15% at one or two concentrations among 4-5 concentrations studied. The clinical applicability of the method was assessed by the preliminary pharmacokinetic study of PG, CG, and CPB in six healthy volunteers with the individually known phenotypes (extensive and poor metabolizers) of S-mephenytoin 4'-hydroxylation, suggesting that individuals with a poor metabolizer phenotype of S-mephenytoin have a much lower capacity to bioactivate PG to CG compared with the extensive metabolizers.
Mass Spectrometric Rapid Diagnosis of Infectious Diseases.
1980-01-01
the analytical procedures to warrant reporting anew the whole analytical procedure. A. Sample Collection and Storage Procedure Urine samples were...positives or false-negatives. Next we have carried out a longitudinal study on urine samples obtained from groups of volunteer subjects vaccinated with...sterilization and storage procedures. 2. Developed new, simpler sample preparation techniques including one to handle tissue culture media. 3. Improved on the
Remane, Daniela; Grunwald, Soeren; Hoeke, Henrike; Mueller, Andrea; Roeder, Stefan; von Bergen, Martin; Wissenbach, Dirk K
2015-08-15
During the last decades exposure sciences and epidemiological studies attracts more attention to unravel the mechanisms for the development of chronic diseases. According to this an existing HPLC-DAD method for determination of creatinine in urine samples was expended for seven analytes and validated. Creatinine, uric acid, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid, and 2-methylhippuric acid were separated by gradient elution (formate buffer/methanol) using an Eclipse Plus C18 Rapid Resolution column (4.6mm×100mm). No interfering signals were detected in mobile phase. After injection of blank urine samples signals for the endogenous compounds but no interferences were detected. All analytes were linear in the selected calibration range and a non weighted calibration model was chosen. Bias, intra-day and inter-day precision for all analytes were below 20% for quality control (QC) low and below 10% for QC medium and high. The limits of quantification in mobile phase were in line with reported reference values but had to be adjusted in urine for homovanillic acid (45mg/L), niacinamide 58.5(mg/L), and indole-3-acetic acid (63mg/L). Comparison of creatinine data obtained by the existing method with those of the developed method showing differences from -120mg/L to +110mg/L with a mean of differences of 29.0mg/L for 50 authentic urine samples. Analyzing 50 authentic urine samples, uric acid, creatinine, hippuric acid, and 2-methylhippuric acid were detected in (nearly) all samples. However, homovanillic acid was detected in 40%, niacinamide in 4% and indole-3-acetic acid was never detected within the selected samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Andersson, Maria; Scheidweiler, Karl B.; Sempio, Cristina; Barnes, Allan; Huestis, Marilyn A.
2016-01-01
A comprehensive cannabinoids urine quantification method may improve clinical and forensic results interpretation and is necessary to support our clinical research. A liquid chromatography tandem mass spectrometry quantification method for Δ9-tetrahydrocannabinol (THC), 11-hydroxy-THC (11-OH-THC), 11-nor-9-carboxy-THC (THCCOOH), Δ9-tetrahydrocannabinolic acid (THCAA), cannabinol (CBN), cannabidiol (CBD), cannabigerol (CBG), Δ9-tetrahydrocannabivarin (THCV), 11-nor-9-carboxy-THCV (THCVCOOH), THC-glucuronide (THC-gluc) and THCCOOH-gluc (THCCOOH-gluc) in urine was developed and validated according to the Scientific Working Group on Toxicology guidelines. Sample preparation consisted of disposable pipette extraction (WAX-S) of 200μL urine. Separation was achieved on a Kinetex C18 column using gradient elution with flow rate 0.5 mL/min, mobile phase A (10 mM ammonium acetate in water) and mobile phase B (15% methanol in acetonitrile). Total run time was 14 min. Analytes were monitored in both positive and negative ionization modes by scheduled multiple reaction monitoring. Linear ranges were 0.5–100 μg/L for THC and THCCOOH, 0.5–50 μg/L for 11-OH-THC, CBD, CBN, THCAA and THC-gluc, 1–100 μg/L for CBG, THCV and THCVCOOH and 5–500 μg/L for THCCOOH-gluc (R2>0.99). Analytical biases were 88.3–113.7%, imprecisions 3.3–14.3%, extraction efficiencies 42.4–81.5% and matrix effect −10 to 32.5%. We developed and validated a comprehensive, simple and rapid LC-MS/MS cannabinoid urine method for quantification of 11 cannabinoids and metabolites. This method is being used in a controlled cannabis administration study, investigating urine cannabinoid markers documenting recent cannabis use, chronic frequent smoking or route of drug administration and potentially improving urine cannabinoid result interpretation. PMID:27422645
Manoni, Fabio; Gessoni, Gianluca; Fogazzi, Giovanni Battista; Alessio, Maria Grazia; Caleffi, Alberta; Gambaro, Giovanni; Epifani, Maria Grazia; Pieretti, Barbara; Perego, Angelo; Ottomano, Cosimo; Saccani, Graziella; Valverde, Sara; Secchiero, Sandra
2016-01-01
With these guidelines the Intersociety Urinalysis Group (GIAU) aims to stimulate the following aspects: Improvement and standardization of the analytical approach to physical, chemical and morphological urine examination (ECMU). Improvement of the chemical analysis of urine with particular regard to the reconsideration of the diagnostic significance of the parameters that are traditionally evaluated in dipstick analysis together with an increasing awareness of the limits of sensitivity and specificity of this analytical method. Increase the awareness of the importance of professional skills in the field of urinary morphology and the relationship with the clinicians. Implement a policy of evaluation of the analytical quality by using, in addition to traditional internal and external controls, a program for the evaluation of morphological competence. Stimulate the diagnostics industry to focus research efforts and development methodology and instrumental catering on the needs of clinical diagnosis. The hope is to revalue the enormous diagnostic potential of 'ECMU, implementing a urinalysis on personalized diagnostic needs for each patient. Emphasize the value added to ECMU by automated analyzers for the study of the morphology of the corpuscular fraction urine. The hope is to revalue the enormous potential diagnostic of 'ECMU, implementing a urinalysis on personalized diagnostic needs that each patient brings with it.
Schindler, Birgit K; Koslitz, Stephan; Meier, Swetlana; Belov, Vladimir N; Koch, Holger M; Weiss, Tobias; Brüning, Thomas; Käfferlein, Heiko U
2012-04-17
N-Methyl- and N-ethyl-2-pyrollidone (NMP and NEP) are frequently used industrial solvents and were shown to be embryotoxic in animal experiments. We developed a sensitive, specific, and robust analytical method based on cooled-injection (CIS) gas chromatography and isotope dilution mass spectrometry to analyze 5-hydroxy-N-ethyl-2-pyrrolidone (5-HNEP) and 2-hydroxy-N-ethylsuccinimide (2-HESI), two newly identified presumed metabolites of NEP, and their corresponding methyl counterparts (5-HNMP, 2-HMSI) in human urine. The urine was spiked with deuterium-labeled analogues of these metabolites. The analytes were separated from urinary matrix by solid-phase extraction and silylated prior to quantification. Validation of this method was carried out by using both, spiked pooled urine samples and urine samples from 56 individuals of the general population with no known occupational exposure to NMP and NEP. Interday and intraday imprecision was better than 8% for all metabolites, while the limits of detection were between 5 and 20 μg/L depending on the analyte. The high sensitivity of the method enables us to quantify NMP and NEP metabolites at current environmental exposures by human biomonitoring.
Dettmer, K; Hanna, D; Whetstone, P; Hansen, R; Hammock, B D
2007-08-01
Autism is a complex neurodevelopmental disorder with unknown etiology. One hypothesis regarding etiology in autism is the "opioid peptide excess" theory that postulates that excessive amounts of exogenous opioid-like peptides derived from dietary proteins are detectable in urine and that these compounds may be pathophysiologically important in autism. A selective LC-MS/MS method was developed to analyze gliadinomorphin, beta-casomorphin, deltorphin 1, and deltorphin 2 in urine. The method is based on on-line SPE extraction of the neuropeptides from urine, column switching, and subsequent HPLC analysis. A limit of detection of 0.25 ng/mL was achieved for all analytes. Analyte recovery rates from urine ranged between 78% and 94%, with relative standard deviations of 0.2-6.8%. The method was used to screen 69 urine samples from children with and without autism spectrum disorders for the occurrence of neuropeptides. The target neuropeptides were not detected above the detection limit in either sample set.
Martin, Rafaela; Schürenkamp, Jennifer; Gasse, Angela; Pfeiffer, Heidi; Köhler, Helga
2013-05-01
A validated method for the simultaneous determination of psilocin, bufotenine, lysergic acid diethylamide and its metabolites in serum, plasma and urine using liquid chromatography-electrospray ionization/tandem mass spectrometry was developed. During the solid-phase extraction procedure with polymeric mixed-mode cation exchange columns, the unstable analytes were protected by ascorbic acid, drying with nitrogen and exclusion of light. The limits of detection and quantitation for all analytes were low. Recovery was ≥86 % for all analytes and no significant matrix effects were observed. Interday and intraday imprecisions at different concentrations ranged from 1.1 to 8.2 % relative standard deviation, bias was within ±5.3 %. Processed samples were stable in the autosampler for at least 2 days. Furthermore, freeze/thaw and long-term stability were investigated. The method was successfully applied to authentic serum and urine samples.
Courtade-Saïdi, Monique; Fleury Feith, Jocelyne
2015-10-01
The pre-analytical step includes sample collection, preparation, transportation and storage in the pathology unit where the diagnosis is performed. The pathologist ensures that pre-analytical conditions are in line with expectations. The lack of standardization for handling cytological samples makes this pre-analytical step difficult to harmonize. Moreover, this step depends on the nature of the sample: fresh liquid or fixed material, air-dried smears, liquid-based cytology. The aim of the study was to review the different practices in French structures of pathology on the pre-analytical phase concerning cytological fluids such as broncho-alveolar lavage (BALF), serous fluids and urine. A survey was conducted on the basis of the pre-analytical chapter of the ISO 15189 and sent to 191 French pathological structures (105 public and 86 private). Fifty-six laboratories replied to the survey. Ninety-five per cent have a computerized management system and 70% a manual on sample handling. The general instructions requested for the patients and sample identification were highly correctly filled with a short time routing and additional tests prescription. By contrast, information are variable concerning the clinical information requested and the type of tubes for collecting fluids and the volumes required as well as the actions taken in case of non-conformity. For the specific items concerning BALF, serous fluids and urine, this survey has shown a great heterogeneity according to sample collection, fixation and of clinical information. This survey demonstrates that the pre-analytical quality for BALF, serous fluids and urine is not optimal and that some corrections of the practices are recommended with a standardization of numerous steps in order to increase the reproducibility of additional tests such as immunocytochemistry, cytogenetic and molecular biology. Some recommendations have been written. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Bukve, Tone; Røraas, Thomas; Riksheim, Berit Oddny; Christensen, Nina Gade; Sandberg, Sverre
2015-01-01
The Norwegian Quality Improvement of Primary Care Laboratories (Noklus) offers external quality assurance (EQA) schemes (EQASs) for urine albumin (UA) annually. This study analyzed the EQA results to determine how the analytical quality of UA analysis in general practice (GP) offices developed between 1998 (n=473) and 2012 (n=1160). Two EQA urine samples were distributed yearly to the participants by mail. The participants measured the UA of each sample and returned the results together with information about their instrument, the profession and number of employees at the office, frequency of internal quality control (IQC), and number of analyses per month. In the feedback report, they received an assessment of their analytical performance. The number of years that the GP office had participated in Noklus was inversely related to the percentage of "poor" results for quantitative but not semiquantitative instruments. The analytical quality improved for participants using quantitative instruments who received an initial assessment of "poor" and who subsequently changed their instrument. Participants using reagents that had expired or were within 3 months of the expiration date performed worse than those using reagents that were expiring in more than 3 months. Continuous participation in the Noklus program improved the performance of quantitative UA analyses at GP offices. This is probably in part attributable to the complete Noklus quality system, whereby in addition to participating in EQAS, participants are visited by laboratory consultants who examine their procedures and provide practical advice and education regarding the use of different instruments.
Intercomparison of analytical methods for arsenic speciation in human urine.
Crecelius, E; Yager, J
1997-06-01
An intercomparison exercise was conducted for the quantification of arsenic species in spiked human urine. The primary objective of the exercise was to determine the variance among laboratories in the analysis of arsenic species such as inorganic As (As+3 and As+5), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA). Laboratories that participated had previous experience with arsenic speciation analysis. The results of this interlaboratory comparison are encouraging. There is relatively good agreement on the concentrations of these arsenic species in urine at concentrations that are relevant to research on the metabolism of arsenic in humans and other mammals. Both the accuracy and precision are relatively poor for arsenic concentrations of less than about 5 micrograms/l.
Ongay, Sara; Hendriks, Gert; Hermans, Jos; van den Berge, Maarten; ten Hacken, Nick H T; van de Merbel, Nico C; Bischoff, Rainer
2014-01-24
In spite of the data suggesting the potential of urinary desmosine (DES) and isodesmosine (IDS) as biomarkers for elevated lung elastic fiber turnover, further validation in large-scale studies of COPD populations, as well as the analysis of longitudinal samples is required. Validated analytical methods that allow the accurate and precise quantification of DES and IDS in human urine are mandatory in order to properly evaluate the outcome of such clinical studies. In this work, we present the development and full validation of two methods that allow DES and IDS measurement in human urine, one for the free and one for the total (free+peptide-bound) forms. To this end we compared the two principle approaches that are used for the absolute quantification of endogenous compounds in biological samples, analysis against calibrators containing authentic analyte in surrogate matrix or containing surrogate analyte in authentic matrix. The validated methods were employed for the analysis of a small set of samples including healthy never-smokers, healthy current-smokers and COPD patients. This is the first time that the analysis of urinary free DES, free IDS, total DES, and total IDS has been fully validated and that the surrogate analyte approach has been evaluated for their quantification in biological samples. Results indicate that the presented methods have the necessary quality and level of validation to assess the potential of urinary DES and IDS levels as biomarkers for the progression of COPD and the effect of therapeutic interventions. Copyright © 2014 Elsevier B.V. All rights reserved.
Maher, Anthony D; Zirah, Séverine F M; Holmes, Elaine; Nicholson, Jeremy K
2007-07-15
1H NMR spectroscopy potentially provides a robust approach for high-throughput metabolic screening of biofluids such as urine and plasma, but sample handling and preparation need careful optimization to ensure that spectra accurately report biological status or disease state. We have investigated the effects of storage temperature and time on the 1H NMR spectral profiles of human urine from two participants, collected three times a day on four different days. These were analyzed using modern chemometric methods. Analytical and preparation variation (tested between -40 degrees C and room temperature) and time of storage (to 24 h) were found to be much less influential than biological variation in sample classification. Statistical total correlation spectroscopy and discriminant function methods were used to identify the specific metabolites that were hypervariable due to preparation and biology. Significant intraindividual variation in metabolite profiles were observed even for urine collected on the same day and after at least 6 h fasting. The effect of long-term storage at different temperatures was also investigated, showing urine is stable if frozen for at least 3 months and that storage at room temperature for long periods (1-3 months) results in a metabolic profile explained by bacterial activity. Presampling (e.g., previous day) intake of food and medicine can also strongly influence the urinary metabolic profiles indicating that collective detailed participant historical meta data are important for interpretation of metabolic phenotypes and for avoiding false biomarker discovery.
Quantification of six herbicide metabolites in human urine.
Norrgran, Jessica; Bravo, Roberto; Bishop, Amanda M; Restrepo, Paula; Whitehead, Ralph D; Needham, Larry L; Barr, Dana B
2006-01-18
We developed a sensitive, selective and precise method for measuring herbicide metabolites in human urine. Our method uses automated liquid delivery of internal standards and acetate buffer and a mixed polarity polymeric phase solid phase extraction of a 2 mL urine sample. The concentrated eluate is analyzed using high-performance liquid chromatography-tandem mass spectrometry. Isotope dilution calibration is used for quantification of all analytes. The limits of detection of our method range from 0.036 to 0.075 ng/mL. The within- and between-day variation in pooled quality control samples range from 2.5 to 9.0% and from 3.2 to 16%, respectively, for all analytes at concentrations ranging from 0.6 to 12 ng/mL. Precision was similar with samples fortified with 0.1 and 0.25 ng/mL that were analyzed in each run. We validated our selective method against a less selective method used previously in our laboratory by analyzing human specimens using both methods. The methods produced results that were in agreement, with no significant bias observed.
Hendrikx, Jeroen J M A; Rosing, Hilde; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H
2014-02-01
A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human feces and urine is described. The drugs were extracted from 200 μL urine or 50 mg feces followed by high-performance liquid chromatography analysis coupled with positive ionization electrospray tandem mass spectrometry. The validation program included calibration model, accuracy and precision, carry-over, dilution test, specificity and selectivity, matrix effect, recovery and stability. Acceptance criteria were according to US Food and Drug Administration guidelines on bioanalytical method validation. The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel, 2-2000 ng/mL for ritonavir in urine, 2-2000 ng/mg for paclitaxel and docetaxel, and 8-8000 ng/mg for ritonavir in feces. Inter-assay accuracy and precision were tested for all analytes at four concentration levels and were within 8.5% and <10.2%, respectively, in both matrices. Recovery at three concentration levels was between 77 and 94% in feces samples and between 69 and 85% in urine samples. Method development, including feces homogenization and spiking blank urine samples, are discussed. We demonstrated that each of the applied drugs could be quantified successfully in urine and feces using the described assay. The method was successfully applied for quantification of the analytes in feces and urine samples of patients. Copyright © 2013 John Wiley & Sons, Ltd.
Saeidi, Iman; Barfi, Behruz; Payrovi, Moazameh; Feizy, Javid; Sheibani, Hojat A; Miri, Mina; Ghollasi Moud, Farahnaz
2015-01-01
With polyamide (PA) as an efficient sorbent for solid phase extraction (SPE) of Sudan dyes II, III and Red 7B from saffron and urine, their determination by HPLC was performed. The optimum conditions for SPE were achieved using 7 mL methanol/water (1:9, v/v, pH 7) as the washing solvent and 3 mL tetrahydrofuran for elution. Good clean-up and high (above 90%) recoveries were observed for all the analytes. The optimized mobile phase composition for HPLC analysis of these compounds was methanol-water (70:30, v/v). The SPE parameters, such as the maximum loading capacity and breakthrough volume, were also determined for each analyte. The limits of detection (LODs), limits of quantification (LOQs), linear ranges and recoveries for the analytes were 4.6-6.6 microg/L, 13.0-19.8 microg/L, 13.0-5000 microg/L (r2>0.99) and 92.5%-113.4%, respectively. The precisions (RSDs) of the overall analytical procedure, estimated by five replicate measurements for Sudan II, III and Red 7B in saffron and urine samples were 2.3%, 1.8% and 3.6%, respectively. The developed method is simple and successful in the application to the determination of Sudan dyes in saffron and urine samples with HPLC coupled with UV detection.
Sánchez-González, Juan; Jesús Tabernero, María; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2016-01-15
A magnetic molecularly imprinted polymer (MMIP) has been synthesized and applied for cocaine (COC) and metabolites (benzoylecgonine, BZE; cocaethylene, CE; and ecgonine methyl ester, EME) recognition/pre-concentration in urine samples. The MMIP has been prepared using COC as a template molecule, ethylene dimethacrylate (EDMA) as a functional monomer, divinylbenzene (DVB) as a cross-linker, Fe3O4 magnetite as a magnetic component, and 2,2'-azobisisobutyronitrile (AIBN) as an initiator. The best results (MIP layer on the surface of the magnetic nanoparticles) and physical properties of the prepared MMIP were obtained when assisting the synthesis procedure with ultrasounds (325W, 37kHz, 30°C, 4h). After solid phase extraction (SPE) with the prepared adsorbent material, analytes were determined by high performance liquid chromatography - tandem mass spectrometry (HPLC-MS/MS). Variables affecting the SPE process (batch mode) were fully evaluated. Optimum retention of analytes (1.8mL of urine and 50mg of MMIP) was achieved by fixing the urine pH at 5.5 (use of a KH2PO4/NaOH, pH 5.5 buffer solution), and magnetic stirring (25°C, 700rpm) for 10min. Elution was performed by using 2mL of a dichloromethane/2-propanol/ammonium hydroxide (75:20:5) mixture under ultrasounds (325W, 35kHz, room temperature) for 5min. The method was validated according to the guidance for bioanalytical method validation of the US Department of Health and Human Services, Food and Drug Administration. The detection limits were in the range of 0.39-1.4ngL(-1). The relative standard deviations of intra- and inter-day tests ranged from 5 to 11% and from 3 to 11%, respectively. Analytical recoveries were in the range of 79-106% when spiking drug-free urine samples at three concentration levels. Good results were also obtained after analyzing an FDT +25% control material. The applicability of the method was proved for screening/quantifying COC, BZE, CE and EME in several samples from poly-drug abusers. Copyright © 2015 Elsevier B.V. All rights reserved.
Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew
2007-01-01
The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.
Metabolomic analysis of urine samples by UHPLC-QTOF-MS: Impact of normalization strategies.
Gagnebin, Yoric; Tonoli, David; Lescuyer, Pierre; Ponte, Belen; de Seigneux, Sophie; Martin, Pierre-Yves; Schappler, Julie; Boccard, Julien; Rudaz, Serge
2017-02-22
Among the various biological matrices used in metabolomics, urine is a biofluid of major interest because of its non-invasive collection and its availability in large quantities. However, significant sources of variability in urine metabolomics based on UHPLC-MS are related to the analytical drift and variation of the sample concentration, thus requiring normalization. A sequential normalization strategy was developed to remove these detrimental effects, including: (i) pre-acquisition sample normalization by individual dilution factors to narrow the concentration range and to standardize the analytical conditions, (ii) post-acquisition data normalization by quality control-based robust LOESS signal correction (QC-RLSC) to correct for potential analytical drift, and (iii) post-acquisition data normalization by MS total useful signal (MSTUS) or probabilistic quotient normalization (PQN) to prevent the impact of concentration variability. This generic strategy was performed with urine samples from healthy individuals and was further implemented in the context of a clinical study to detect alterations in urine metabolomic profiles due to kidney failure. In the case of kidney failure, the relation between creatinine/osmolality and the sample concentration is modified, and relying only on these measurements for normalization could be highly detrimental. The sequential normalization strategy was demonstrated to significantly improve patient stratification by decreasing the unwanted variability and thus enhancing data quality. Copyright © 2016 Elsevier B.V. All rights reserved.
Meyer, Markus R; Caspar, Achim; Brandt, Simon D; Maurer, Hans H
2014-01-01
The first synthetic tryptamines have entered the designer drug market in the late 1990s and were distributed as psychedelic recreational drugs. In the meantime, several analogs have been brought onto the market indicating a growing interest in this drug class. So far, only scarce analytical data were available on the detectability of tryptamines in human biosamples. Therefore, the aim of the presented study was the development and full validation of a method for their detection in human urine and plasma and their quantification in human plasma. The liquid chromatography-linear ion trap mass spectrometry method presented covered 37 tryptamines as well as five β-carbolines, ibogaine, and yohimbine. Compounds were analyzed after protein precipitation of urine or fast liquid-liquid extraction of plasma using an LXQ linear ion trap coupled to an Accela ultra ultra high-performance liquid chromatography system. Data mining was performed via information-dependent acquisition or targeted product ion scan mode with positive electrospray ionization. The assay was selective for all tested substances with limits of detection in urine between 10 and 100 ng/mL and in plasma between 1 and 100 ng/mL. A validated quantification in plasma according to international recommendation could be demonstrated for 33 out of 44 analytes.
Sánchez-Guijo, Alberto; Hartmann, Michaela F; Shi, Lijie; Remer, Thomas; Wudy, Stefan A
2014-01-01
Urinary free cortisol and urinary free cortisone are decisive markers for the diagnosis of syndromes related to the dysfunction of the adrenal gland or to evaluate certain enzymatic disorders. Here, we present a new method, designed for routine laboratory use, which enables quick determination of these analytes with minor sample workup. Turbulent flow chromatography shortens sample preparation, and connection to a fused-core particle-packed column (rugged amide-embedded C18 phase) permits a rapid and effective separation of the analytes, as well as additional separation from other related and isobaric compounds present in urine. Urinary isobaric compounds were successfully identified. The method requires only 100 μl of urine supernatant per sample. The total time between injections is 9.5 min. The solvents used for both turbulent and analytical chromatography are water and methanol, and the relatively low flows needed during the method resulted in an extended life of the columns. Linearity showed a R (2) > 0.994. Limit of detection and limit of quantification are 0.5 and 1.0 ng/ml for cortisone and 1.0 and 2.0 ng/ml for cortisol. Recoveries ranged from 99.7 to 109.1 % for cortisone and from 98.7 to 102.9 % for cortisol. Accuracy values (relative errors) for intra- and inter-assay experiments were always below 8 %, whereas precision (percent CV) ranged from 3.7 to 10.7 %. No matrix effects were detected during the validation process. The reproducibility for each analyte's retention time was excellent, with a coefficient of variation always below 0.2 %. The final validation step included the study of urine samples from healthy children and from children previously diagnosed with corticoidal disorders. The high selectivity achieved enables quick data handling.
Ali, Nurshad; Muñoz, Katherine; Degen, Gisela H
2017-06-05
Ochratoxin A (OTA), a mycotoxin known for its nephrotoxic and carcinogenic properties, is a worldwide occurring contaminant in a variety of food commodities. Biomonitoring (i.e. analysis in biological fluids) can serve to assess human internal exposure from all consumed foods and beverages. We now determined the concentration of OTA and its metabolite ochratoxin alpha (OTα) in plasma and in urine of two male volunteers with different food habits, in order to assess intra-individual temporal fluctuations and inter-individual differences in their biomarker levels. Moreover, the urinary levels of both OTA and OTα were analyzed in a cohort of German adults (23 males, 27 females) on their regular diet. All samples were subjected to an enzymatic hydrolysis of biomarker conjugates prior to clean-up by liquid-liquid extraction and HPLC-FD analysis. The profile in the first individual showed small fluctuations over time: mean levels in plasma were 0.42 and 0.45ng/mL for OTA and OTα, respectively, and in urine means of 0.06ng/mL for both analytes. The other individual had mean levels of 1.64 and 0.20ng/mL for OTA and OTα in plasma, and 0.24 and 2.22ng/mL for these analytes in urine. It is concluded that inter-individual differences in biomarker levels reflect dissimilar dietary exposure and/or disposition of ingested mycotoxin, with an apparently more efficient detoxification of OTA to OTα in the second individual. In the German cohort (n=50), analytes were detected in 100% (OTA: range 0.02-1.82ng/mL mean level 0.21±0.31ng/mL) and 78% (OTα: range 0.01-14.25ng/mL, mean level 1.33±2.63ng/mL) of all urines. Parameters such as gender, age and body mass index did not show a significant association with urine biomarker levels. This study indicates frequent exposure to OTA among German adults. The new results are discussed in the context of biomarker data from other countries and some methodological issues. Copyright © 2017 Elsevier B.V. All rights reserved.
Jet Fuel Exposure and Neurological Health in Military Personnel
2011-07-01
and dermal samples E Absorbed Dose measure: Exhaled breath, urine , blood F Lifestyle factors (smoking), use of protective equipment (gloves...toluene, ethylbenzene, xylene, and naphthalene. To assess personal absorbed dose levels to JP8 components, exhaled breath and urine samples were...the following primary analytes of interest were measured: benzene, toluene, ethylbenzene, xylene, and naphthalene. Pre- and post- shift urine samples
Serrano, María; Gallego, Mercedes; Silva, Manuel
2016-03-11
Endogenous aldehydes (EAs) generated during oxidative stress and cell processes are associated with many pathogenic and toxicogenic processes. The aim of this research was to develop a solvent-free and automated analytical method for the determination of EAs in human urine using a static headspace generator sampler coupled with gas chromatography-mass spectrometry (HS-GC-MS). Twelve significant EAs used as markers of different biochemical and physiological processes, namely short- and medium-chain alkanals, α,β-unsaturated aldehydes and dicarbonyl aldehydes have been selected as target analytes. Human urine samples (no dilution is required) were derivatized with O-2,3,4,5,6-pentafluorobenzylhydroxylamine in alkaline medium (hydrogen carbonate-carbonate buffer, pH 10.3). The HS-GC-MS method developed renders an efficient tool for the sensitive and precise determination of EAs in human urine with limits of detection from 1 to 15ng/L and relative standard deviations, (RSDs) from 6.0 to 7.9%. Average recoveries by enriching urine samples ranged between 92 and 95%. Aldehydes were readily determined at 0.005-50μg/L levels in human urine from healthy subjects, smokers and diabetic adults. Copyright © 2016 Elsevier B.V. All rights reserved.
Schot, Marjolein J C; van Delft, Sanne; Kooijman-Buiting, Antoinette M J; de Wit, Niek J; Hopstaken, Rogier M
2015-05-18
Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Delta-9-tetrahydrocannabinolic acid A (THC-A) in urine of a 15-month-old child: A case report.
Morini, Luca; Quaiotti, Jessica; Moretti, Matteo; Osculati, Antonio Marco Maria; Tajana, Luca; Groppi, Angelo; Vignali, Claudia
2018-05-01
The acidic forms of cannabinoids, THC-A and CBD-A are naturally present in cannabis plants and preparations and are generally decarboxylated to the active compounds before the use (e.g. thermally decarboxylated through smoking). Hence, the identification of the acidic compounds in urine could be an evidence of cannabis ingestion rather than a passive exposure to smoke. This case report described a 15-month-old child that suffered an acute intoxication by accidental cannabis ingestion. It is important to assess the ingestion and to discriminate it from a passive exposure to better interpret the clinical findings and to establish the correct therapeutic procedure. Urine samples were simply diluted in deionized water and directly injected in the LC-MS/MS system. D 3 -THCCOOH was used as internal standard. Chromatographic separation of THCCOOH, THC-A and CBD-A was carried out in reversed phase on a c18 column. A triple quad in MRM negative mode was used to monitor the three analytes. The developed LC-MS/MS method was simple and fast. A LOD of 3.0ng/mL and a LOQ of 10.0ng/mL were measured for the three compounds. The analytical procedure was validated accordingly to international guidelines. The two urine samples collected from the 15-month-old child at the hospitalization and after three days provided positive results for THCCOOH (130.0 and 10.0ng/mL respectively). THC-A was found only in the urine sample collected at the hospitalization (concentration: 70.0ng/mL). THC-A was detected and quantitated in a urine sample of a 15-month-old child. Copyright © 2018 Elsevier B.V. All rights reserved.
Andersson, Maria; Stephanson, Nikolai; Ohman, Inger; Terzuoli, Tommy; Lindh, Jonatan D; Beck, Olof
2014-04-01
Opiates comprise a class of abused drugs that is of primary interest in clinical and forensic urine drug testing. Determination of heroin, codeine, or a multi-drug ingestion is complicated since both heroin and codeine can lead to urinary excretion of free and conjugated morphine. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) offers advantage over gas chromatography-mass spectrometry by simplifying sample preparation but increases the number of analytes. A method based on direct injection of five-fold diluted urine for confirmation of morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, codeine-6-glucuronide and 6-acetylmorphine was validated using LC-MS/MS in positive electrospray mode monitoring two transitions using selected reaction monitoring. The method was applied for the analysis of 3155 unknown urine samples which were positive for opiates in immunochemical screening. A linear response was observed for all compounds in the calibration curves covering more than three orders of magnitude. Cut off was set to 2 ng/ml for 6-acetylmorphine and 150 ng/ml for the other analytes. 6-Acetylmorphine was found to be effective (sensitivity 82%) in detecting samples as heroin intake. Morphine-3-glucuronide and codeine-6-glucuronide was the predominant components of total morphine and codeine, 84% and 93%, respectively. The authors have validated a robust LC-MS/MS method for rapid qualitative and quantitative analysis of opiates in urine. 6-Acetylmorphine has been demonstrated as a sensitive and important parameter for a heroin intake. A possible interpretation strategy to conclude the source of detected analytes was proposed. The method might be further developed by reducing the number of analytes to morphine-3-glucuronide, codeine-6-glucuronide and 6-acetylmorphine without compromising test performance. Copyright © 2013 John Wiley & Sons, Ltd.
Gerace, E; Salomone, A; Abbadessa, G; Racca, S; Vincenti, M
2012-02-01
A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid-liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration.
Gerace, E.; Salomone, A.; Abbadessa, G.; Racca, S.; Vincenti, M.
2011-01-01
A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid–liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration. PMID:29403714
Nestić, Marina; Babić, Sandra; Pavlović, Dragana Mutavdžić; Sutlović, Davorka
2013-09-10
In presented paper analytical method based on solid-phase extraction using molecularly imprinted polymer and gas chromatography-mass spectrometry has been developed and validated for the confirmation of THC, THC-OH and THC-COOH in urine samples. Non-covalent molecularly imprinted polymers of THC-OH were prepared using different functional monomers (methacrylic acid, 4-vinylpyridine, and 2-hydroxyethyl methacrylate), ethylene glycol dimethacrylate as a cross-linker and 2,2'-azobis-isobutyronitrile as an initiator of radical polymerization. Analytes were extracted from urine samples using prepared polymer sorbent with highest binding selectivity and capability. Before extraction, urine samples were hydrolyzed with alkaline. Elution was performed with chloroform:ethyl acetate (60:40, v/v). Dry extracts were silylated with BSTFA+1% TMCS. Detection and quantification were performed using gas chromatography-mass spectrometry in single ion recording mode. The developed method was linear over the range from LOQ to 150 ng mL(-1) for all three analytes. For THC, THC-OH and THC-COOH LOD was 2.5, 1 and 1 ng mL(-1), and LOQ was 3, 2 and 2 ng mL(-1), respectively. The precision, accuracy, recovery and matrix effect were investigated at 5, 25 and 50 ng mL(-1). In the investigated concentration range recoveries were 71.9% for THC, 78.6% for THC-OH and 75.2% for THC-COOH. Matrix effect was not significant (<10%) for all analytes in the concentration range from 5 ng mL(-1) to 50 ng mL(-1). Extraction recovery on non-imprinted polymer was relatively high indicating high non-specific binding. Optimized and validated method was applied to 15 post-mortem urine samples. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Kocer, Derya; Sarıguzel, Fatma M; Karakukcu, Cıgdem
2014-08-01
The microscopic analysis of urine is essential for the diagnosis of patients with urinary tract infections. Quantitative urine culture is the 'gold standard' method for definitive diagnosis of urinary-tract infections, but it is labor-intensive, time consuming, and does not provide the same-day results. The aim of this study was to evaluate the analytical and diagnostic performance of the FUS200 (Changchun Dirui Industry, China), a new urine sedimentation analyzer in comparison to urine culture as the reference method. We evaluated 1000 urine samples, submitted for culture and urine analysis with a preliminary diagnosis of urinary-tract infection. Cut-off values for the FUS200 were determined by comparing the results with urine cultures. The cut-off values by the receiver operating characteristic (ROC) curve technique, sensitivity, and specificity were calculated for bacteria and white blood cells (WBCs). Among the 1000 urine specimens submitted for culture, 637 cultures (63.7%) were negative, and 363 were (36.3%) positive. The best cut-off values obtained from ROC analysis were 16/μL for bacteriuria (sensitivity: 82.3%, specificity: 58%), and 34/μL for WBCs (sensitivity: 72.3%, specificity: 65.2%). The area under the curve (AUC) for the bacteria and WBCs count were 0.71 (95% CI: 0.67-0.74) and, 0.72 (95% CI: 0.69-0.76) respectively. The most important requirement of a rapid diagnostic screening test is sensitivity, and, in this perspective, an unsatisfactory sensitivity by using bacteria recognition and quantification performed by the FUS200 analyzer has been observed. After further technical improvements in particle recognition and laboratory personnel training, the FUS200 might show better results.
Ionization Suppression and Recovery in Direct Biofluid Analysis Using Paper Spray Mass Spectrometry
NASA Astrophysics Data System (ADS)
Vega, Carolina; Spence, Corina; Zhang, Chengsen; Bills, Brandon J.; Manicke, Nicholas E.
2016-04-01
Paper spray mass spectrometry is a method for the direct analysis of biofluid samples in which extraction of analytes from dried biofluid spots and electrospray ionization occur from the paper on which the dried sample is stored. We examined matrix effects in the analysis of small molecule drugs from urine, plasma, and whole blood. The general method was to spike stable isotope labeled analogs of each analyte into the spray solvent, while the analyte itself was in the dried biofluid. Intensity of the labeled analog is proportional to ionization efficiency, whereas the ratio of the analyte intensity to the labeled analog in the spray solvent is proportional to recovery. Ion suppression and recovery were found to be compound- and matrix-dependent. Highest levels of ion suppression were obtained for poor ionizers (e.g., analytes lacking basic aliphatic amine groups) in urine and approached -90%. Ion suppression was much lower or even absent for good ionizers (analytes with aliphatic amines) in dried blood spots. Recovery was generally highest in urine and lowest in blood. We also examined the effect of two experimental parameters on ion suppression and recovery: the spray solvent and the sample position (how far away from the paper tip the dried sample was spotted). Finally, the change in ion suppression and analyte elution as a function of time was examined by carrying out a paper spray analysis of dried plasma spots for 5 min by continually replenishing the spray solvent.
Peer, Cody J; Shakleya, Diaa M; Younis, Islam R; Kraner, James C; Callery, Patrick S
2007-10-01
A rapid mass spectrometric method was developed for the identification of fentanyl and its major hepatic metabolite norfentanyl in postmortem urine of six drug-overdose victims involving fentanyl use. To reduce matrix effects or ion suppression, sample preparation consisted of centrifugation and solid-phase extraction. Deuterium-labeled internal standards ((2)H(5)-fentanyl and (2)H(5)-norfentanyl) were used to compensate for instrument variation in signal, analyte recovery during sample preparation, and ion suppression. Structural information for fentanyl and norfentanyl were collected using mass spectrometry (MS) with electrospray ionization (ESI) operated in the positive ion mode. Fentanyl (m/z 337) was found in each of the six overdose cases by the appearance of the MS-MS daughter ion on both an ion trap and a triple-quadrupole MS resulting from the fragmentation pathway of fentanyl (m/z 337 --> 188). Norfentanyl was detected in all six cases by the appearance of the MH(+) ion, m/z 233, with a single-quadrupole MS and confirmed in an ion trap MS. Ion suppression, as determined by the comparison of ion intensities from spiked samples in water with postmortem urine from the cases, ranged from 18% to 98% in three ESI sources. The use of stable isotope-labeled internal standards obviates sample preparation because ratios of analyte/internal standard remain constant in the presence of extensive matrix effects. This MS method provided sufficient sensitivity and selectivity for the rapid identification of fentanyl and norfentanyl in urine at levels >/= 10 ng/mL without prior analyte resolution by chromatography and with a total analysis time of less than 1 h.
Intercomparison of analytical methods for arsenic speciation in human urine.
Crecelius, E; Yager, J
1997-01-01
An intercomparison exercise was conducted for the quantification of arsenic species in spiked human urine. The primary objective of the exercise was to determine the variance among laboratories in the analysis of arsenic species such as inorganic As (As+3 and As+5), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA). Laboratories that participated had previous experience with arsenic speciation analysis. The results of this interlaboratory comparison are encouraging. There is relatively good agreement on the concentrations of these arsenic species in urine at concentrations that are relevant to research on the metabolism of arsenic in humans and other mammals. Both the accuracy and precision are relatively poor for arsenic concentrations of less than about 5 micrograms/l. PMID:9288500
Quality assurance in the pre-analytical phase of human urine samples by (1)H NMR spectroscopy.
Budde, Kathrin; Gök, Ömer-Necmi; Pietzner, Maik; Meisinger, Christine; Leitzmann, Michael; Nauck, Matthias; Köttgen, Anna; Friedrich, Nele
2016-01-01
Metabolomic approaches investigate changes in metabolite profiles, which may reflect changes in metabolic pathways and provide information correlated with a specific biological process or pathophysiology. High-resolution (1)H NMR spectroscopy is used to identify metabolites in biofluids and tissue samples qualitatively and quantitatively. This pre-analytical study evaluated the effects of storage time and temperature on (1)H NMR spectra from human urine in two settings. Firstly, to evaluate short time effects probably due to acute delay in sample handling and secondly, the effect of prolonged storage up to one month to find markers of sample miss-handling. A number of statistical procedures were used to assess the differences between samples stored under different conditions, including Projection to Latent Structure Discriminant Analysis (PLS-DA), non-parametric testing as well as mixed effect linear regression analysis. The results indicate that human urine samples can be stored at 10 °C for 24 h or at -80 °C for 1 month, as no relevant changes in (1)H NMR fingerprints were observed during these time periods and temperature conditions. However, some metabolites most likely of microbial origin showed alterations during prolonged storage but without facilitating classification. In conclusion, the presented protocol for urine sample handling and semi-automatic metabolite quantification is suitable for large-scale epidemiological studies. Copyright © 2015 Elsevier Inc. All rights reserved.
Ground Test of the Urine Processing Assembly for Accelerations and Transfer Functions
NASA Technical Reports Server (NTRS)
Houston, Janice; Almond, Deborah F. (Technical Monitor)
2001-01-01
This viewgraph presentation gives an overview of the ground test of the urine processing assembly for accelerations and transfer functions. Details are given on the test setup, test data, data analysis, analytical results, and microgravity assessment. The conclusions of the tests include the following: (1) the single input/multiple output method is useful if the data is acquired by tri-axial accelerometers and inputs can be considered uncorrelated; (2) tying coherence with the matrix yields higher confidence in results; (3) the WRS#2 rack ORUs need to be isolated; (4) and future work includes a plan for characterizing performance of isolation materials.
Badoud, F; Grata, E; Perrenoud, L; Avois, L; Saugy, M; Rudaz, S; Veuthey, J-L
2009-05-15
The general strategy to perform anti-doping analyses of urine samples starts with the screening for a wide range of compounds. This step should be fast, generic and able to detect any sample that may contain a prohibited substance while avoiding false negatives and reducing false positive results. The experiments presented in this work were based on ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry. Thanks to the high sensitivity of the method, urine samples could be diluted 2-fold prior to injection. One hundred and three forbidden substances from various classes (such as stimulants, diuretics, narcotics, anti-estrogens) were analysed on a C(18) reversed-phase column in two gradients of 9min (including two 3min equilibration periods) for positive and negative electrospray ionisation and detected in the MS full scan mode. The automatic identification of analytes was based on retention time and mass accuracy, with an automated tool for peak picking. The method was validated according to the International Standard for Laboratories described in the World Anti-Doping Code and was selective enough to comply with the World Anti-Doping Agency recommendations. In addition, the matrix effect on MS response was measured on all investigated analytes spiked in urine samples. The limits of detection ranged from 1 to 500ng/mL, allowing the identification of all tested compounds in urine. When a sample was reported positive during the screening, a fast additional pre-confirmatory step was performed to reduce the number of confirmatory analyses.
Volatile substance abuse--post-mortem diagnosis.
Wille, Sarah M R; Lambert, Willy E E
2004-06-10
A substantial number of children and adolescents world-wide abuse volatile substances with the intention to experience an euphoric state of consciousness. Although the ratio of deaths to nonfatal inhalation escapades is low, it is an important and preventable cause of death in young people. In the analytical investigation of volatile substances proper sample collection, storage and handling are important in view of the volatile nature of the compounds. Volatile organic compounds in post-mortem matrices such as blood, urine and tissues are generally determined by gas chromatography after extracting the compounds with methods such as static and dynamic headspace or even with pulse-heating and solvent extraction. In post-mortem cases, metabolites in urine seem less relevant, however, trichloroethanol and trichloroacetic acid were determined in several cases. When interpreting qualitative and quantitative results, researchers should be aware of false conclusions. The main reason why scepticism is necessary is the occurrence of losses of analytes during sampling, sample handling and storage, which results in false quantitation.
Long-Term Stability of Volatile Nitrosamines in Human Urine.
Hodgson, James A; Seyler, Tiffany H; Wang, Lanqing
2016-07-01
Volatile nitrosamines (VNAs) are established teratogens and carcinogens in animals and classified as probable (group 2A) and possible (group 2B) carcinogens in humans by the IARC. High levels of VNAs have been detected in tobacco products and in both mainstream and sidestream smoke. VNA exposure may lead to lipid peroxidation and oxidative stress (e.g., inflammation), chronic diseases (e.g., diabetes) and neurodegenerative diseases (e.g., Alzheimer's disease). To conduct epidemiological studies on the effects of VNA exposure, short-term and long-term stabilities of VNAs in the urine matrix are needed. In this report, the stability of six VNAs (N-nitrosodimethylamine, N-nitrosomethylethylamine, N-nitrosodiethylamine, N-nitrosopiperidine, N-nitrosopyrrolidine and N-nitrosomorpholine) in human urine is analyzed for the first time using in vitro blank urine pools fortified with a standard mixture of all six VNAs. Over a 24-day period, analytes were monitored in samples stored at ∼20°C (collection temperature), 4-10°C (transit temperature) and -20 and -70°C (long-term storage temperatures). All six analytes were stable for 24 days at all temperatures (n = 15). The analytes were then analyzed over a longer time period at -70°C; all analytes were stable for up to 1 year (n = 62). A subset of 44 samples was prepared as a single batch and stored at -20°C, the temperature at which prepared samples are stored. These prepared samples were run in duplicate weekly over 10 weeks, and all six analytes were stable over the entire period (n = 22). Published by Oxford University Press 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.
The incidence of elevations in urine 5-hydroxyindoleacetic acid.
Nuttall, K L; Pingree, S S
1998-01-01
A 24-hour urine collection for 5-hydroxyindoleacetic acid (HIAA) is commonly performed to evaluate patients with suspected carcinoid syndrome. However, carcinoids are rare, and elevated results are common even when using an analytically specific method. To characterize this problem, the incidence of elevated results was examined in a population of 947 patient specimens received in a clinical reference laboratory setting. Using a reference limit of 15 mg/d identified 7.9 percent of the results as elevated, with 3 percent > 100 mg/d, and about 1 percent > 350 mg/d. Males showed 14 percent > 15 mg/d compared to 5.2 percent for females. Characterization of incomplete and excess 24-hr urine collections is facilitated by use of a creatinine ratio, with a reference limit of 14 mg/g creatinine equivalent to 15 mg/d. Given the frequency of elevated results, HIAA should be used to support the diagnoses of carcinoid only when consistent with other objective findings.
Znaleziona, Joanna; Ginterová, Pavlína; Petr, Jan; Ondra, Peter; Válka, Ivo; Ševčík, Juraj; Chrastina, Jan; Maier, Vítězslav
2015-05-18
Synthetic cannabinoids have gained popularity due to their easy accessibility and psychoactive effects. Furthermore, they cannot be detected in urine by routine drug monitoring. The wide range of active ingredients in analyzed matrices hinders the development of a standard analytical method for their determination. Moreover, their possible side effects are not well known which increases the danger. This review is focused on the sample preparation and the determination of synthetic cannabinoids in different matrices (serum, urine, herbal blends, oral fluid, hair) published since 2004. The review includes separation and identification techniques, such as thin layer chromatography, gas and liquid chromatography and capillary electrophoresis, mostly coupled with mass spectrometry. The review also includes results by spectral methods like infrared spectroscopy, nuclear magnetic resonance or direct-injection mass spectrometry. Copyright © 2015 Elsevier B.V. All rights reserved.
Stability of Drugs of Abuse in Urine Samples at Room Temperature by Use of a Salts Mixture.
Pellegrini, Manuela; Graziano, Silvia; Mastrobattista, Luisa; Minutillo, Adele; Busardo, Francesco Paolo; Scarsella, Gianfranco
2017-01-01
It has long been recognized that ensuring analyte stability is of crucial importance in the use of any quantitative bioanalytical method. As analyses are usually not performed directly after collection of the biological samples, but after these have been processed and stored, it is essential that analyte stability can be maintained at storage conditions to ensure that the obtained concentration results adequately reflect those directly after sampling. The conservation of urine samples in refrigerated/ frozen conditions is strongly recommended; but not always feasible. The aim of this study was to assess the stability of some well-known drugs of abuse methamphetamine (MA), 11-nor-9-carboxy-Δ9- tetrahydrocannabinol (THC-COOH), benzoylecgonine (BE), and morphine (MOR) in urine samples kept at room temperature by adding a salt mixture (sodium citrate, sodium ascorbate, borax). Two different urine samples were prepared with and without salt mixture, stored at room temperature and then analyzed by gas chromatography-mass spectrometry at 0, 1, 7, 15, and 30 days after collection/preparation to look for eventual analyte degradation. Methamphetamine showed no significant changes with respect to the time of collection/ preparation (T0) up to 7 days later (T7), with or without salt mixture addiction. Then a significant degradation occurred in both salted and non salted urine. BE decrease was observed starting from day 1 after sample collection in salted and not salted samples, respectively. Salt addition seemed to reduce at least the initial BE degradation, with a significant difference (p<0.001) at 7 and 15 days of storage. However, the degradation was not more prevented in salted samples at 30 days of storage. A 20% decrease of MOR concentration was observed starting from day 1 after collection/preparation, both in salted and not salted samples with no subsequent decrease. With regard to THCCOOH, a significant decrease was observed starting from 7 days after collection/preparation, with of without adding the salt mixture. However, when comparing salted versus non salted samples at each time point, a statistically significant difference was observed at 7 and 30 days of storage. The results obtained indicate that the degradation of MA, THC-COOH and BE in urine samples kept at room temperature can be slowed by the addition of the salt mixture, whereas it seems to be ineffective in samples containing MOR. This evidence has to be taken into account, in the eventuality of using salted urine to prevent in a certain extent abuse of above-reported drugs of abuse. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Stanley, Shawn M R; Foo, Hsiao Ching
2006-05-19
A rapid, selective and robust direct-injection LC/hybrid tandem MS method has been developed for simultaneous screening of more than 250 basic drugs in the supernatant of enzyme hydrolysed equine urine. Analytes, trapped using a short HLB extraction column, are refocused and separated on a Sunfire C(18) analytical column using a controlled differential gradient generated by proportional dilution of the first column's eluent with water. Independent data acquisition (IDA) was configured to trigger a sensitive enhanced product ion (EPI) scan when a multiple reaction monitoring (MRM) survey scan signal exceeded the defined criteria. The decision on whether or not to report a sample as a positive result was based upon both the presence of a MRM response within the correct retention time range and a qualitative match between the EPI spectrum obtained and the corresponding reference standard. Ninety seven percent of the drugs targeted by this method met our detection criteria when spiked into urine at 100 ng/ml; 199 were found at 10 ng/ml, 83 at 1 ng/ml and 4 at 0.1 ng/ml.
Shephard, M D S; Allen, G G; Paizis, K; Barbara, J A J; Batterham, M; Vanajek, A
2006-01-01
There has been a significant increase in the burden of renal disease among Aboriginal Australians over the past 15 years. Urine albumin:creatinine ratio (ACR) is a well-established marker of microalbuminuria and can be conveniently performed on the DCA 2000 point-of-care testing (POCT) analyser (Bayer Australia; Melbourne, VIC, Australia) with an on-site result available in 7 min. The application of the urine ACR POCT for renal disease risk assessment was pioneered by our group in the Umoona Kidney Project. This article describes the results of the management arm of the Umoona Kidney Project, which used point-of-care urine ACR testing for the first time within a management framework to monitor albuminuria in patients at highest risk of renal disease. The article also examines the analytical quality of POCT results and overall community acceptance of the Umoona Kidney Project. Adults clinically assessed by Flinders Medical Centre renal specialists as being at greatest risk for renal disease were offered the ACE inhibitor (ACEI) perindopril on a voluntary basis. Selected renal markers, including POCT urine ACR (conducted on-site by Umoona's Aboriginal health worker team), plasma electrolytes, urea, creatinine, calculated glomerular filtration rate and blood pressure were measured six monthly. Regular quality control testing was undertaken to monitor the analytical performance of the POCT analyser. A culturally appropriate questionnaire was designed and implemented to assess community satisfaction with the project. In all, 231 patient management consultations were conducted over a two year period, with over 70% of patients having four or more (up to a maximum of eight) consultations; 35 patients (mean age 49.2 [+/-2.3] years, 54% males) participated voluntarily in the management arm. All were overtly hypertensive, hypertensive with other risk factors or had diabetes. The renal status of these patients was followed for a mean of 63 +/- 4.5 weeks. In total, 111 POCT urine ACR tests were performed for patient management (mean 3.2 tests per patient). There was no significant difference in POCT urine ACR in the study period with a median (and inter-quartile range) of 5.7 mg/mmol (1.2-15.2) pre-ACEI and 4.3 mg/mmol (1.3-16.7) post-ACEI treatment (p = 0.50, Wilcoxon signed ranks test). The calculated glomerular filtration rate altered from 110 to 118 mL/min (p = 0.019, paired t-test). There was no change in the group plasma potassium, urea and creatinine. Collectively these results indicate a stabilisation in renal function among the management group. Blood pressure (both lying and standing) fell significantly in the study period. The imprecision for urine ACR quality control POCT conducted during the management program was within nationally and internationally accepted precision goals for urine albumin, creatinine and ACR. Fifty community members completed the satisfaction questionnaire. Three-quarters of respondents felt there were no cultural barriers in providing a urine sample for urine ACR POCT. The management arm of the Umoona Kidney Project was effective in stabilising the renal function and improving the blood pressure of community members identified to be at greatest risk of kidney disease. POCT urine ACR testing can be utilised, not only for community risk assessment, but also for patient management. The Umoona Kidney Project was well accepted by the health service and community members.
Urine and oral fluid drug testing in support of pain management.
Kwong, Tai C; Magnani, Barbarajean; Moore, Christine
2017-09-01
In recent years, the abuse of opioid drugs has resulted in greater prevalence of addiction, overdose, and deaths attributable to opioid abuse. The epidemic of opioid abuse has prompted professional and government agencies to issue practice guidelines for prescribing opioids to manage chronic pain. An important tool available to providers is the drug test for use in the initial assessment of patients for possible opioid therapy, subsequent monitoring of compliance, and documentation of suspected aberrant drug behaviors. This review discusses the issues that most affect the clinical utility of drug testing in chronic pain management with opioid therapy. It focuses on the two most commonly used specimen matrices in drug testing: urine and oral fluid. The advantages and disadvantages of urine and oral fluid in the entire testing process, from specimen collection and analytical methodologies to result interpretation are reviewed. The analytical sensitivity and specificity limitations of immunoassays used for testing are examined in detail to draw attention to how these shortcomings can affect result interpretation and influence clinical decision-making in pain management. The need for specific identification and quantitative measurement of the drugs and metabolites present to investigate suspected aberrant drug behavior or unexpected positive results is analyzed. Also presented are recent developments in optimization of test menus and testing strategies, such as the modification of the standard screen and reflexed-confirmation testing model by eliminating some of the initial immunoassay-based tests and proceeding directly to definitive testing by mass spectrometry assays.
51Cr-EDTA absorption blood test: an easy method for assessing small intestinal permeability in dogs.
Frias, Rafael; Sankari, Satu; Westermarck, Elias
2004-01-01
The 51Cr-EDTA test is a valuable clinical tool for screening intestinal diseases in dogs. The test is performed by calculating the percentage of recovery from urine of a PO-ingested dose of 51Cr-EDTA after 6 or 24 hours. Careful urine collection is a practical limitation of this test in dogs, and our goal was to develop a simpler test that measures 51Cr-EDTA in blood. A 51Cr-EDTA absorption test was simultaneously performed on urine and serum 43 times in healthy Beagle Dogs. Timed blood samples were withdrawn, and urine was collected during a 6-hour period. Percentages of the ingested dose were then calculated in urine and serum. The mean +/- standard deviation (range) percentage in urine after 6 hours was 14.07 +/- 8.72% (3.81-34.18%), whereas results in serum from samples taken at 2, 3, 4, 5, and 6 hours were 0.49 +/- 0.45% (0.02-2.13%), 0.75 +/- 0.52% (0.03-1.89%), 0.82 +/- 0.57% (0.13-2.21%), 0.70 +/- 0.53% (0.12-1.99%), and 0.47 +/- 0.44% (0.11-1.79%), respectively. The results for blood specimens showed good concordance with those for urine, especially for the samples taken at 4 hours (r = 0.89). Moreover, the correlation between urine and blood was better when the sum of the percentages of the recovered analyte from various blood samples was compared with urine. The correlation coefficient when summing 4 blood samples was excellent (r = 0.97) and remained excellent when summing only 2 blood samples taken at 3 and 5 hours (r = 0.95) or at 3 and 4 hours (r = 0.94). We conclude that a serum 51Cr-EDTA test determined by summing successive blood samples provides an easier means of estimating small intestinal permeability in dogs and gives results comparable to those of the 6-hour urine test.
Velasco, Roberto; Benito, Helvia; Mozun, Rebeca; Trujillo, Juan E; Merino, Pedro A; de la Torre, Mercedes; Gomez, Borja; Mintegi, Santiago
2016-12-01
Guidelines from the American Academy of Pediatrics define urinary tract infection (UTI) as the growth of greater than 50,000 ufc/mL of a single bacterium in a urine culture with a positive urine dipstick or with a urinalysis associated. Our objective was to evaluate the adequacy of this cutoff point for the diagnosis of UTI in young febrile infants. Subanalysis of a prospective multicenter study developed in RISeuP-SPERG Network between October 11 and September 13. To carry out the study, it was performed a comparison of analytical and microbiological characteristics of patients younger than 90 days with fever without focus, taking into account the results of urine dipstick and urine culture. Of a total of 3333 infants younger than 90 days with fever without focus which were included in the study, 538 were classified as UTI in accordance with American Academy of Pediatrics' guidelines. These patients were similar to those who had a positive urine dipstick and a urine culture yielding of 10,000 to 50,000 ufc/mL, and they were different from those who had a normal urine dipstick and a urine culture >50,000 ufc/mL, being focused on the isolated bacteria and blood biomarkers values. Forty-five invasive bacterial infections were diagnosed (5.9% of the 756 with a urine culture >10,000 ufc/mL). Half of the infants with a normal urine dipstick diagnosed with invasive bacterial infections were younger than 15 days. It might be inadequate to use a threshold of 50,000 cfu/mL to consider a urine culture as positive in young febrile infants given the fact that it would misdiagnose several UTIs.
Wang, Chunyan; Zhu, Hongbin; Pi, Zifeng; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2013-09-15
An analytical method for quantifying underivatized amino acids (AAs) in urine samples of rats was developed by using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Classification of type 2 diabetes rats was based on urine amino acids metabolic profiling. LC-MS/MS analysis was applied through chromatographic separation and multiple reactions monitoring (MRM) transitions of MS/MS. Multivariate profile-wide predictive models were constructed using partial least squares discriminant analysis (PLS-DA) by SIMAC-P 11.5 version software package and hierarchical cluster analysis (HCA) by SPSS 18.0 version software. Some amino acids in urine of rats have significant change. The results of the present study prove that this method could perform the quantification of free AAs in urine of rats by using LC-MS/MS. In summary, the PLS-DA and HCA statistical analysis in our research were preferable to differentiate healthy rats and type 2 diabetes rats by the quantification of AAs in their urine samples. In addition, comparing with health group the seven increased amino acids in urine of type 2 rats were returned to normal under the treatment of acarbose. Copyright © 2013 Elsevier B.V. All rights reserved.
Bonanno, Lisa M.; Kwong, Tai C.; DeLouise, Lisa A.
2010-01-01
In this work we evaluate for the first time the performance of a label-free porous silicon (PSi) immunosensor assay in a blind clinical study designed to screen authentic patient urine specimens for a broad range of opiates. The PSi opiate immunosensor achieved 96% concordance with liquid chromatography-mass spectrometry/tandem mass spectrometry (LC-MS/MS) results on samples that underwent standard opiate testing (n=50). In addition, successful detection of a commonly abused opiate, oxycodone, resulted in 100% qualitative agreement between the PSi opiate sensor and LC-MS/MS. In contrast, a commercial broad opiate immunoassay technique (CEDIA®) achieved 65% qualitative concordance with LC-MS/MS. Evaluation of important performance attributes including precision, accuracy, and recovery was completed on blank urine specimens spiked with test analytes. Variability of morphine detection as a model opiate target was < 9% both within-run and between-day at and above the cutoff limit of 300 ng ml−1. This study validates the analytical screening capability of label-free PSi opiate immunosensors in authentic patient samples and is the first semi-quantitative demonstration of the technology’s successful clinical use. These results motivate future development of PSi technology to reduce complexity and cost of diagnostic testing particularly in a point-of-care setting. PMID:21062030
Janus, Tomasz; Jasionowicz, Ewa; Potocka-Banaś, Barbara; Borowiak, Krzysztof
Routine toxicological analysis is mostly focused on the identification of non-organic and organic, chemically different compounds, but generally with low mass, usually not greater than 500–600 Da. Peptide compounds with atomic mass higher than 900 Da are a specific analytical group. Several dozen of them are highly-toxic substances well known in toxicological practice, for example mushroom toxin and animal venoms. In the paper the authors present an example of alpha-amanitin to explain the analytical problems and different original solutions in identifying peptides in urine samples with the use of the universal LC MS/MS procedure. The analyzed material was urine samples collected from patients with potential mushroom intoxication, routinely diagnosed for amanitin determination. Ultra filtration with centrifuge filter tubes (limited mass cutoff 3 kDa) was used. Filtrate fluid was directly injected on the chromatographic column and analyzed with a mass detector (MS/MS). The separation of peptides as organic, amphoteric compounds from biological material with the use of the SPE technique is well known but requires dedicated, specific columns. The presented paper proved that with the fast and simple ultra filtration technique amanitin can be effectively isolated from urine, and the procedure offers satisfactory sensitivity of detection and eliminates the influence of the biological matrix on analytical results. Another problem which had to be solved was the non-characteristic fragmentation of peptides in the MS/MS procedure providing non-selective chromatograms. It is possible to use higher collision energies in the analytical procedure, which results in more characteristic mass spectres, although it offers lower sensitivity. The ultra filtration technique as a procedure of sample preparation is effective for the isolation of amanitin from the biological matrix. The monitoring of selected mass corresponding to transition with the loss of water molecule offers satisfactory sensitivity of determination.
Paper-Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine.
Jalal, Uddin M; Jin, Gyeong Jun; Shim, Joon S
2017-12-19
In this work, a disposable paper-plastic hybrid microfluidic lab-on-a-chip (LOC) has been developed and successfully applied for the colorimetric measurement of urine by the smartphone-based optical platform using a "UrineAnalysis" Android app. The developed device was cost-effectively implemented as a stand-alone hybrid LOC by incorporating the paper-based conventional reagent test strip inside the plastic-based LOC microchannel. The LOC device quantitatively investigated the small volume (40 μL) of urine analytes for the colorimetric reaction of glucose, protein, pH, and red blood cell (RBC) in integration with the finger-actuating micropump. On the basis of our experiments, the conventional urine strip showed large deviation as the reaction time goes by, because dipping the strip sensor in a bottle of urine could not control the reaction volume. By integrating the strip sensor in the LOC device for urine analysis, our device significantly improves the time-dependent inconstancy of the conventional dipstick-based urine strip, and the smartphone app used for image analysis enhances the visual assessment of the test strip, which is a major user concern for the colorimetric analysis in point-of-care (POC) applications. As a result, the user-friendly LOC, which is successfully implemented in a disposable format with the smartphone-based optical platform, may be applicable as an effective tool for rapid and qualitative POC urinalysis.
Code of Federal Regulations, 2010 CFR
2010-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2013 CFR
2013-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2014 CFR
2014-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2012 CFR
2012-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2011 CFR
2011-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Yang, Chun-Chun; Yang, Stephen Shei-Dei; Hung, Hui-Ching; Chiang, I-Ni; Peng, Chiung-Hui; Chang, Shang-Jen
2017-09-01
To evaluate the ability of laser flow cytometry to predict cocci/mixed growth in the pre-analytical phase of urine specimens. We retrospectively reviewed urine samples from women with uncomplicated urinary tract infections from urologic clinics for study. Urine analyses were performed with laser flow cytometry (UF1000i, Sysmex, Kobe, Japan) and then diagrams were generated (forward scatter vs. fluorescent light scatter). Each specimen (bacteria count >357 BACT/μL) was classified as either cocci bacteria or rods/mixed growth according to the diagrams. Standard urine cultures were performed, and the agreement between cultures and the UF1000i interpretations was analyzed with kappa statistics. Finally, 491 specimens met the criteria for analysis. Among the 376 specimens with single bacteria growth, there were 26 gram-positive cocci (13 Streptococci spp., 7 Staphylococci spp., 6 Enterococci spp.), 1 gram-positive rods (Corynebacterium spp.), and 349 gram-negative rods (273 Escherichia coli, 33 Klebsiella spp., 29 Proteus spp., 6 Citrobacter spp., 4 Enterobacter spp., 3 Pseudomonas spp., and 1 Providencia spp.). There were 115 specimens with two bacteria species or more that were regarded as mixed growth. Agreement of rods or cocci/mixed growth between the laser flow cytometry and urine cultures yielded a kappa value of 0.58. The positive and negative predictive rate of the UF1000i for cocci/mixed growth in voided urine culture was 81.8% and 84.7%, respectively. Through laser flow cytometry, we can predict growth of cocci/mixed growth in the pre-analytical phase of urine culture, thus avoiding unnecessary urine culture and waiting time. © 2016 Wiley Periodicals, Inc.
Development of automated analytical capability for the early detection of diabetes mellitus
NASA Technical Reports Server (NTRS)
Zlatkis, A.
1976-01-01
The total profile of volatile metabolites in urine of patients with diabetes mellitus was studied. Because of the drastic abnormalities in the metabolism of carbohydrates, lipids, and proteins connected with diabetes it was expected that apart from acetone further characteristic abnormalities occur in the profiles if volatile urinary metabolites in cases of diabetes mellitus. Quantitative and qualitative changes were found in these urines as compared to the urines of normal subjects.
Estimation of Cutoff Values of Cotinine in Urine and Saliva for Pregnant Women in Poland
Polańska, Kinga
2013-01-01
Setting appropriate cutoff values and the use of a highly sensitive analytical method allow for correct classification of the smoking status. Urine-saliva pairs samples of pregnant women in the second and third trimester, and saliva only in the first trimester were collected. Offline SPE and LC-ESI-MS/MS method was developed in the broad concentration range (saliva 0.4–1000 ng/mL, urine 0.8–4000 ng/mL). The mean recoveries were 3.7 ± 7.6% for urine and 99.1 ± 2.6% for saliva. LOD for saliva was 0.12 ng/mL and for urine 0.05 ng/mL; LOQ was 0.4 ng/mL and 0.8 ng/mL, respectively. Intraday and interday precision equaled, respectively, 1.2% and 3.4% for urine, and 2.3% and 6.4% for saliva. There was a strong correlation between salivary cotinine and the uncorrected cotinine concentration in urine in the second and third trimesters of pregnancy. The cutoff values were established for saliva 12.9 ng/mL and urine 42.3 ng/mL or 53.1 μg/g creatinine with the ROC curve analysis. The developed analytical method was successfully applied to quantify cotinine, and a significant correlation between the urinary and salivary cotinine levels was found. The presented cut-off values for salivary and urinary cotinine ensure a categorization of the smoking status among pregnant women that is more accurate than self-reporting. PMID:24228246
Saugy, M; Avois, L; Saudan, C; Robinson, N; Giroud, C; Mangin, P; Dvorak, J
2006-07-01
Cannabis is on the list of prohibited substances in the practice of sport, although its performance enhancing effect has not yet been proved. Its popularity among the younger generations as a social drug puts cannabis at the top of the list of compounds detected by the anti-doping laboratories accredited by the World Anti-Doping Agency worldwide. The management of the results of urine analysis is quite difficult for the medical and disciplinary committees not only because of the social use of the substance, but also because of the interpretation of the analytical data from urine samples. This paper gives an overview of what is presently known about cannabis in relation with the practice of sport. Review of literature on the cannabis and exercise, its effect in the body, and the problems with interpretation of results when it is detected in urine. The paper outlines the major effects of cannabis in the context of its social use and its use for sport activities. The difficulties in the interpretation of urine sample analysis results because of the protracted excretion time of the main metabolite, long after the intake, are described. There is an urgent need for sport authorities to take measures necessary to avoid players misusing cannabis.
Chen, Chun-Hsien; Chao, Yu-Ying; Lin, Yi-Hui; Chen, Yen-Ling
2018-04-27
The on-line preconcentration technique of field-enhanced sample stacking and sweeping (FESS-sweeping) are combined with dispersive liquid-liquid microextraction (DLLME) to monitor the concentrations of finasteride, which is used in the treatment of androgenetic alopecia, and its metabolite, finasteride carboxylic acid (M3), in urine samples. DLLME is used to concentrate and eliminate the interferences of urine samples and uses chloroform as an extracting solvent and acetonitrile as a disperser solvent. A high conductivity buffer (HCB) was introduced into capillary and then sample plug (90.7% capillary length) was injected into capillary. After applying voltage, the sodium dodecyl sulfate (SDS) swept the analytes from the low conductivity sample solution into HCB. The analytes were concentrated on the field-enhanced sample stacking boundary. The limit of detection for the analytes is 20 ng mL -1 . The sensitivity enrichment of finasteride and M3 are 362-fold and 480-fold, respectively, compared with the conventional MEKC method. The on-line preconcentration technique of field-enhanced sample stacking and sweeping possess good selectivity because the endogenous steroid did not interfere the detection of finasteride and M3. The analytical technique is applied to investigate the concentrations in urine samples from patients who have been administered finasteride for the treatment of androgenetic alopecia; the amount of M3 detected in 12 h was 72.69 ± 4.18 μg. Copyright © 2018 Elsevier B.V. All rights reserved.
Houtman, Corine J; Sterk, Saskia S; van de Heijning, Monique P M; Brouwer, Abraham; Stephany, Rainer W; van der Burg, Bart; Sonneveld, Edwin
2009-04-01
Anabolic androgenic steroids (AAS) are a class of steroid hormones related to the male hormone testosterone. They are frequently detected as drugs in sport doping control. Being similar to or derived from natural male hormones, AAS share the activation of the androgen receptor (AR) as common mechanism of action. The mammalian androgen responsive reporter gene assay (AR CALUX bioassay), measuring compounds interacting with the AR can be used for the analysis of AAS without the necessity of knowing their chemical structure beforehand, whereas current chemical-analytical approaches may have difficulty in detecting compounds with unknown structures, such as designer steroids. This study demonstrated that AAS prohibited in sports and potential designer AAS can be detected with this AR reporter gene assay, but that also additional steroid activities of AAS could be found using additional mammalian bioassays for other types of steroid hormones. Mixtures of AAS were found to behave additively in the AR reporter gene assay showing that it is possible to use this method for complex mixtures as are found in doping control samples, including mixtures that are a result of multi drug use. To test if mammalian reporter gene assays could be used for the detection of AAS in urine samples, background steroidal activities were measured. AAS-spiked urine samples, mimicking doping positive samples, showed significantly higher androgenic activities than unspiked samples. GC-MS analysis of endogenous androgens and AR reporter gene assay analysis of urine samples showed how a combined chemical-analytical and bioassay approach can be used to identify samples containing AAS. The results indicate that the AR reporter gene assay, in addition to chemical-analytical methods, can be a valuable tool for the analysis of AAS for doping control purposes.
Mendes, Michele P Rocha; Silveira, Josianne Nicácio; Andre, Leiliane Coelho
2017-09-15
Benzene is an important occupational and environmental contaminant, naturally present in petroleum and as by-product in the steel industry. Toxicological studies showed pronounced myelotoxic action, causing leukemic and others blood cells disorders. Assessing of benzene exposure is performed by biomarkers as trans, trans-muconic acid (AttM) and S-phenylmercapturic acid (S-PMA) in urine. Due to specificity of S-PMA, this biomarker has been proposed to asses lower levels of benzene in air. The aim of this study was to validate an analytical method for the quantification of S-PMA by High-Performance Liquid Chromatography with fluorometric detector. The development of an analytical method of S-PMA in urine was carried out by solid phase extraction (SPE) using C-18 phase. The eluated were submitted to water bath at 75°C and nitrogen to analyte concentration, followed by alkaline hydrolysis and derivatization with monobromobimane. The chromatography conditions were reverse phase C-18 column (240mm, 4mm and 5μm) at 35°C; acetonitrile and 0.5% acetic acid (50:50) as mobile phase with a flow of 0.8mL/min. The limits of detection and quantification were 0.22μg/L and 0.68μg/L, respectively. The linearity was verified by simple linear regression, and the method exhibited good linearity in the range of 10-100μg/L. There was no matrix effect for S-PMA using concentrations of 40, 60, 80 and 100μg/L. The intra- and interassay precision showed coefficient of variation of less than 10% and the recovery ranged from 83.4 to 102.8% with an average of 94.4%. The stability of S-PMA in urine stored at -20°C was of seven weeks. The conclusion is that this method presents satisfactory results per their figures of merit. This proposed method for determining urinary S-PMA showed adequate sensitivity for assessment of occupational and environmental exposure to benzene using S-PMA as biomarker of exposure. Copyright © 2017 Elsevier B.V. All rights reserved.
Jensen, Pamela K; Wujcik, Chad E; McGuire, Michelle K; McGuire, Mark A
2016-01-01
Simple high-throughput procedures were developed for the direct analysis of glyphosate [N-(phosphonomethyl)glycine] and aminomethylphosphonic acid (AMPA) in human and bovine milk and human urine matrices. Samples were extracted with an acidified aqueous solution on a high-speed shaker. Stable isotope labeled internal standards were added with the extraction solvent to ensure accurate tracking and quantitation. An additional cleanup procedure using partitioning with methylene chloride was required for milk matrices to minimize the presence of matrix components that can impact the longevity of the analytical column. Both analytes were analyzed directly, without derivatization, by liquid chromatography tandem mass spectrometry using two separate precursor-to-product transitions that ensure and confirm the accuracy of the measured results. Method performance was evaluated during validation through a series of assessments that included linearity, accuracy, precision, selectivity, ionization effects and carryover. Limits of quantitation (LOQ) were determined to be 0.1 and 10 µg/L (ppb) for urine and milk, respectively, for both glyphosate and AMPA. Mean recoveries for all matrices were within 89-107% at three separate fortification levels including the LOQ. Precision for replicates was ≤ 7.4% relative standard deviation (RSD) for milk and ≤ 11.4% RSD for urine across all fortification levels. All human and bovine milk samples used for selectivity and ionization effects assessments were free of any detectable levels of glyphosate and AMPA. Some of the human urine samples contained trace levels of glyphosate and AMPA, which were background subtracted for accuracy assessments. Ionization effects testing showed no significant biases from the matrix. A successful independent external validation was conducted using the more complicated milk matrices to demonstrate method transferability.
Guerrero, Samantha; Pastor, Josep; Tvarijonaviciute, Asta; Cerón, José Joaquín; Balestra, Graziano; Caldin, Marco
2017-11-01
Urine osmolality (UOsm) is considered the most accurate measure of urine concentration and is used to assess body fluid homeostasis and renal function. We performed analytical validation of freezing point depression measurement of canine UOsm, to establish reference intervals (RIs) and to determine the effect of age, sex, and reproductive status on UOsm in dogs. Clinically healthy dogs ( n = 1,991) were retrospectively selected and stratified in groups by age (young [0-12 mo], adults [13-84 mo], and seniors [>84 mo]), sex (females and males), and reproductive status (intact and neutered). RIs were calculated for each age group. Intra- and inter-assay coefficients of variation were <1% in all cases. Good linearity ( r 2 = 1, p < 0.001) and recovery (89-98%) were observed. The limit of detection and limit of quantification were zero. Urine specific gravity and UOsm had a highly significant positive correlation ( r = 0.96, p < 0.001) but had inconsistent agreement. The 95% RI for canine UOsm was 369-2,416 mOsm/kg in young and adult dogs, and 366-2,178 mOsm/kg in seniors. Senior dogs had a significantly lower UOsm than young and adult dogs ( p < 0.000). Neutered females had a significantly lower UOsm than intact female dogs ( p < 0.002). These results indicate that the method evaluated is adequate for UOsm measurement and that RIs based on age and reproductive status should be used in dogs.
Haywood, P E; Teale, P; Moss, M S
1990-07-01
Thoroughbred geldings were fed racehorse cubes containing a predetermined concentration of theobromine in the form of cocoa husk. They were offered 7 kg of cubes per day, divided between morning and evening feed, and food consumption was monitored. Urinary concentrations of theobromine were determined following the consumption of cubes containing 11.5, 6.6, 2.0 and 1.2 mg per kg of theobromine, to verify whether or not such concentrations would produce positive urine tests. Pre-dose urine samples were collected to verify the absence of theobromine before each experiment. It became apparent from the results of the first three administrations that the limit of detection of theobromine, using such procedures, would be reached at a feed level of about 1 mg per kg theobromine. Therefore the final administration, using cubes containing 1.2 mg per kg theobromine, was singled out for additional analytical work and quantitative procedures were developed to measure urinary concentrations of theobromine. It was anticipated that the results would form a basis for discussions relating to the establishment of a threshold value for theobromine in horse urine. The Stewards of the Jockey Club subsequently gave notice that they had established a threshold level for theobromine in urine of 2 micrograms/ml.
Rapid and visual detection of Leptospira in urine by LigB-LAMP assay with pre-addition of dye.
Ali, Syed Atif; Kaur, Gurpreet; Boby, Nongthombam; Sabarinath, T; Solanki, Khushal; Pal, Dheeraj; Chaudhuri, Pallab
2017-12-01
Leptospirosis is considered to be the most widespread zoonotic disease caused by pathogenic species of Leptospira. The present study reports a novel set of primers targeting LigB gene for visual detection of pathogenic Leptospira in urine samples through Loop-mediated isothermal amplification (LAMP). The results were recorded by using Hydroxyl napthol blue (HNB), SYBR GREEN I and calcein. Analytical sensitivity of LAMP was as few as 10 leptospiral organisms in spiked urine samples from cattle and dog. LigB gene based LAMP, termed as LigB-LAMP, was found 10 times more sensitive than conventional PCR. The diagnostic specificity of LAMP was 100% when compared to SYBR green qPCR for detection of Leptospira in urine samples. Though qPCR was found more sensitive, the rapidity and simplicity in setting LAMP test followed by visual detection of Leptospira infection in clinical samples makes LigB-LAMP an alternative and favourable diagnostic tool in resource poor setting. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rossi, Gabriele; Giori, Luca; Campagnola, Simona; Zatelli, Andrea; Zini, Eric; Paltrinieri, Saverio
2012-06-01
To determine whether preanalytic and analytic factors affect evaluation of the urinary protein-to-creatinine (UPC) ratio in dogs. 50 canine urine samples. The UPC ratio was measured to assess the intra-assay imprecision (20 measurements within a single session), the influence of predilution (1:10, 1:20, and 1:100) for urine creatinine concentration measurement, and the effect of storage at room temperature (approx 20°C), 4°C, and -20°C. The coefficient of variation at room temperature determined with the 1:20 predilution was < 10.0%, with the highest coefficients of variation found in samples with a low protein concentration or low urine specific gravity. This variability could result in misclassification of samples with UPC ratios close to the thresholds defined by the International Renal Interest Society to classify dogs as nonproteinuric (0.2), borderline proteinuric (0.21 to 0.50), or proteinuric (> 0.51). A proportional bias was found in samples prediluted 1:10, compared with samples prediluted 1:20 or 1:100. At room temperature, the UPC ratio did not significantly increase after 2 and 4 hours. After 12 hours at room temperature and at 4°C, the UPC ratio significantly increased. The UPC ratio did not significantly change during 3 months of storage at -20°C. The intra-assay precision of the UPC ratio was sufficiently low to avoid misclassification of samples, except for values close to 0.2 or 0.5. The optimal predilution ratio for urine creatinine concentration measurement was 1:20. A 1:100 predilution is recommended in samples with a urine specific gravity > 1.030. The UPC ratio must be measured as soon as samples are collected. Alternatively, samples should be immediately frozen to increase their stability and minimize the risk of misclassification of proteinuria.
Helmlin, Hans-Jörg; Mürner, André; Steiner, Samuel; Kamber, Matthias; Weber, Christina; Geyer, Hans; Guddat, Sven; Schänzer, Wilhelm; Thevis, Mario
2016-10-01
Hydrochlorothiazide (HCTZ, 6-chloro-3,4-dihydro-2H-1,2,4-benzothiadiazine-7-sulfonamide-1,1-dioxide) belongs to the class of diuretic agents that represent one of today's cornerstones of the treatment of hypertensive patients. In addition to its clinical relevance, HCTZ is prohibited in sports according to the regulations of the World Anti-Doping Agency (WADA) at all times and has frequently been detected in sports drug testing urine samples worldwide since its ban was introduced in 1988. Despite these facts, the adverse analytical finding concerning HCTZ in an in-competition routine doping control sample collected in December 2014 was further investigated, particularly motivated by the comparably low urinary concentration of the drug accounting for approximately 5ng/mL. The athlete in question did not declare the use of any nutritional supplement or medication other than the ingestion of a non-steroidal anti-inflammatory drug (NSAID) prior to competition. Hence, the drug (formulated as coated tablet) provided by the athlete as well as the corresponding retention sample of the manufacturer were analyzed. Noteworthy, both samples confirmed the presence of about 2μg of HCTZ per tablet. In order to further probe for the plausibility of the observed urinary HCTZ concentrations with the scenario of drug ingestion and subsequent doping control sample collection, administration studies with produced HCTZ-spiked placebo-tablets (2.5μg of HCTZ/tablet) were conducted. Urine specimens were collected prior to and after ingestion of the drug and subjected to routine doping control analytical procedures employing liquid chromatography/tandem mass spectrometry. While blank urine samples returned negative test results, post-administration specimens were found to contain HCTZ at concentrations of approximately 1-16ng/mL, which supported the athlete's inadvertent intake of HCTZ via contaminated NSAID tablets. Due to the substantial sensitivity of test methods employed today by doping control laboratories, even drug contaminations ranging within the good manufacturing practice (GMP) limit of 10ppm overall carry-over can evidently lead to adverse analytical findings. This calls into question whether selected (classes of) substances such as diuretics should be reported only when exceeding a defined reporting level and/or whether adverse analytical findings of non-threshold substances should be reported with an estimated semi-quantitative concentration of the identified substance to facilitate the result management by anti-doping organizations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Mass spectrometric based approaches in urine metabolomics and biomarker discovery.
Khamis, Mona M; Adamko, Darryl J; El-Aneed, Anas
2017-03-01
Urine metabolomics has recently emerged as a prominent field for the discovery of non-invasive biomarkers that can detect subtle metabolic discrepancies in response to a specific disease or therapeutic intervention. Urine, compared to other biofluids, is characterized by its ease of collection, richness in metabolites and its ability to reflect imbalances of all biochemical pathways within the body. Following urine collection for metabolomic analysis, samples must be immediately frozen to quench any biogenic and/or non-biogenic chemical reactions. According to the aim of the experiment; sample preparation can vary from simple procedures such as filtration to more specific extraction protocols such as liquid-liquid extraction. Due to the lack of comprehensive studies on urine metabolome stability, higher storage temperatures (i.e. 4°C) and repetitive freeze-thaw cycles should be avoided. To date, among all analytical techniques, mass spectrometry (MS) provides the best sensitivity, selectivity and identification capabilities to analyze the majority of the metabolite composition in the urine. Combined with the qualitative and quantitative capabilities of MS, and due to the continuous improvements in its related technologies (i.e. ultra high-performance liquid chromatography [UPLC] and hydrophilic interaction liquid chromatography [HILIC]), liquid chromatography (LC)-MS is unequivocally the most utilized and the most informative analytical tool employed in urine metabolomics. Furthermore, differential isotope tagging techniques has provided a solution to ion suppression from urine matrix thus allowing for quantitative analysis. In addition to LC-MS, other MS-based technologies have been utilized in urine metabolomics. These include direct injection (infusion)-MS, capillary electrophoresis-MS and gas chromatography-MS. In this article, the current progresses of different MS-based techniques in exploring the urine metabolome as well as the recent findings in providing potentially diagnostic urinary biomarkers are discussed. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 36:115-134, 2017. © 2015 Wiley Periodicals, Inc.
Nilsson, Gunnel H; Kugelberg, Fredrik C; Ahlner, Johan; Kronstrand, Robert
2014-01-01
A simple liquid chromatography-tandem mass spectrometry method was validated to allow determination of zopiclone (ZOP), N-desmethylzopiclone (NDZOP), zopiclone N-oxide (ZOPNO) and 2-amino-5-chloropyridine (ACP) in urine at concentrations up to 3,000 ng/mL within 3.5 min. This method was used for quantitative analysis of the analytes in authentic urine samples obtained 10 h after oral administration of zopiclone (Imovane(®)) and in aliquots of the same urine samples after different storage conditions. In addition, pH of each studied urine sample was measured over time. The results showed that formation of ACP occurred at elevated pH and/or temperature by degradation of ZOP, NDZOP and ZOPNO. This method was also applied to samples obtained from two female victims of drug-facilitated assault. One sample had been exposed to long-term storage conditions at different temperatures and at pH >8.2, which resulted in high concentrations of ACP. The other sample, which was exposed to pH <6.5, showed no formation of ACP. ACP is formed both from ZOP and from its metabolites NDZOP and ZOPNO depending on the pH of the urine, time of storage and/or the temperature conditions. For correct interpretation in forensic cases, ZOP, its major metabolites and ACP should be analyzed. When ACP is identified in urine, the concentrations of ZOP, NDZOP and ZOPNO should be interpreted with great caution. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Pratumvinit, Busadee; Reesukumal, Kanit; Wongkrajang, Preechaya; Khejonnit, Varanya; Klinbua, Cherdsak; Dangneawnoi, Weerapol
2013-11-15
Acidification of urine has been recommended before testing for calcium, phosphate, and magnesium. We investigated the necessity of pre-analytical acidification in both crystallized and non-crystallized urine samples. From 130 urine samples obtained via routine urine analysis, 65 (50%) samples were classified as non-crystallized. All samples were divided into three groups: untreated samples, acidified samples with HCl, and acidified samples after 1h room-temperature incubation. Urine samples were measured for calcium, phosphate, magnesium, and creatinine using Modular P800 and were examined for crystals using light microscopy. In crystallized samples, acidified samples with 1h incubation had significantly higher Ca/Cr, P/Cr, and Mg/Cr than did untreated samples with mean differences of 0.04, 0.03, and 0.01 mg/mg, respectively (P<0.001). In acidified samples that were analyzed immediately, crystallized samples had lower calcium concentrations than those of acidified samples with 1h incubation and a mean difference of 0.21 mg/dl (P = 0.025). None of the sample differences which exceeded the critical difference of urinary Ca, P and Mg was observed. Acidification of urine should be performed before the measurement of Ca, P, and Mg in the presence of urinary crystals. However, the lack of an acidification process does not result in a clinically significant change. © 2013.
NASA Astrophysics Data System (ADS)
Qu, Jianan Y.; Suria, David; Wilson, Brian C.
1998-05-01
The primary goal of these studies was to demonstrate that NIR Raman spectroscopy is feasible as a rapid and reagentless analytic method for clinical diagnostics. Raman spectra were collected on human serum and urine samples using a 785 nm excitation laser and a single-stage holographic spectrometer. A partial east squares method was used to predict the analyte concentrations of interest. The actual concentrations were determined by a standard clinical chemistry. The prediction accuracy of total protein, albumin, triglyceride and glucose in human sera ranged from 1.5 percent to 5 percent which is greatly acceptable for clinical diagnostics. The concentration measurements of acetaminophen, ethanol and codeine inhuman urine have demonstrated the potential of NIR Raman technology in screening of therapeutic drugs and substances of abuse.
Urinary levels of bisphenol analogues in residents living near a manufacturing plant in south China.
Yang, Yunjia; Guan, Jian; Yin, Jie; Shao, Bing; Li, Hong
2014-10-01
The use of bisphenol A (BPA) has been restricted in many countries because of its potential health effects. As a result of these restrictions, a group of bisphenol analogues that are structurally similar to BPA have been developed as the alternatives for industrial applications. However, latest researches indicated that these chemicals have similar endocrine-disrupting effects as BPA in humans. Moreover, only a limited number of studies have attempted to monitor the exposure level in humans of other bisphenol analogues. In the present study, the concentrations of seven bisphenols, including bisphenol S (BPS), bisphenol F (BPF), bisphenol B (BPB), BPA, bisphenol AF (BPAF), tetrachlorobisphenol A (TCBPA) and tetrabromobisphenol A (TBBPA), in human urine samples were measured by liquid chromatography coupled to mass spectrometry (LC-MS/MS) following the enzymatic hydrolysis of glucuronidase/arylsulfatase and liquid-liquid extraction (LLE). Under the optimised conditions, high recoveries (81.6-116.8%) were obtained for all the analytes, and the relative standard deviations (RSD, %) were less than 16.4% (n=6). The isotopic internal standard calibration curves for each of the target compounds exhibited excellent linearity (r(2)>0.99) and the limit of quantification (LOQ) for the analytes in urine ranged from 0.024 to 0.310 ng mL(-1). The method was applied to investigate the urinary levels of these seven bisphenols in a cohort of residents living near a BPAF manufacturing plant in south China. BPS, BPF, BPA and BPAF were detected in urine samples at concentrations ranging from
The 24-hour urine collection: gold standard or historical practice?
Côté, Anne-Marie; Firoz, Tabassum; Mattman, André; Lam, Elaine M; von Dadelszen, Peter; Magee, Laura A
2008-12-01
The objective of the study was to determine completeness of 24-hour urine collection in pregnancy. This was a retrospective laboratory/chart review of 24-hour urine collections at British Columbia Women's Hospital. Completeness was assessed by 24-hour urinary creatinine excretion (UcreatV): expected according to maternal weight for single collections and between-measurement difference for serial collections. For 198 randomly selected pregnant women with a hypertensive disorder (63% preeclampsia), 24-hour urine collections were frequently inaccurate (13-54%) on the basis of UcreatV of 97-220 micromol/kg per day (11.0-25.0 mg/kg per day) or 133-177 micromol/kg per day (15.1-20.1 mg/kg per day) of prepregnancy weight (respectively). Lean body weight resulted in more inaccurate collections (24-68%). The current weight was frequently unavailable (28%) and thus not used. For 161 women (81% proteinuric) with serial 24-hour urine levels, a median [interquartile range] of 11 [5-31] days apart, between-measurement difference in UcreatV was 14.4% [6.0-24.9]; 40 women (24.8%) had values 25% or greater, exceeding analytic and biologic variation. Twenty-four hour urine collection is frequently inaccurate and not a precise measure of proteinuria or creatinine clearance.
Habara, P; Marečková, H; Malíčková, K; Potyšová, Z; Hrušková, Z; Zima, T; Tesař, V
2012-01-01
Glomerulonephritides together create a heterogenic group of supposedly immunologically mediated diseases of glomeruli. They still belong among the most frequent causes of chronic renal failure. Detection of podocytes in urine might serve as an important marker of glomerulonephritides activity. The aim of this study was to develop a novel flow cytometric method for the detection of podocyte fragments and podocytes in urine and assess its possible use in clinical practice. We placed emphasis on the improvement of pre-analytic phase. To suppress the autofluorescence of the background, blocking solutions and magnetic separation were used. An additional surface marker CD10 (nephrilysin) was used together with routinely used podocalyxin (PCX) in order to achieve better identification of podocytes. Based on the surface marker expression, three different element types were identified in the urine samples: PCX+/CD10+ elements (EL) (supposedly podocytes), PCX-/CD10+ EL (supposedly parietal epithelial cells) and PCX+ EL. We examined a total of 36 patients who underwent renal biopsy (non-glomerular nephropathy, MGN, FSGS, IgAN, AAV and MPGN) and 27 healthy controls. Negative results were found in non-glomerular nephropathy and in MGN. In patients with FSGS and IgAN, the levels of urine elements were slightly increased. The highest levels of all elements were found in AAV and MPGN. Our first results suggest that flow cytometric detection may distinguish between glomerular and nonglomerular diseases and that the levels of urine elements might correlate with the degree of glomerular destruction.
Hoppin, Jane A; Ulmer, Ross; Calafat, Antonia M; Barr, Dana B; Baker, Susan V; Meltzer, Helle M; Rønningen, Kjersti S
2006-01-01
Collection of urine samples in human studies involves choices regarding shipping, sample preservation, and storage that may ultimately influence future analysis. As more studies collect and archive urine samples to evaluate environmental exposures in the future, we were interested in assessing the impact of urine preservative, storage temperature, and time since collection on nonpersistent contaminants in urine samples. In spiked urine samples stored in three types of urine vacutainers (no preservative, boric acid, and chlorhexidine), we measured five groups of contaminants to assess the levels of these analytes at five time points (0, 24, 48, and 72 h, and 1 week) and at two temperatures (room temperature and 4 degrees C). The target chemicals were bisphenol A (BPA), metabolites of organophosphate (OP), carbamate, and pyrethroid insecticides, chlorinated phenols, and phthalate monoesters, and were measured using five different mass spectrometry-based methods. Three samples were analyzed at each time point, with the exception of BPA. Repeated measures analysis of variance was used to evaluate effects of storage time, temperature, and preservative. Stability was summarized with percent change in mean concentration from time 0. In general, most analytes were stable under all conditions with changes in mean concentration over time, temperature, and preservative being generally less than 20%, with the exception of the OP metabolites in the presence of boric acid. The effect of storage temperature was less important than time since collection. The precision of the laboratory measurements was high allowing us to observe small differences, which may not be important when categorizing individuals into broader exposure groups.
Wang, Zhi; Shi, Zongwei; Xi, Cunxian; Wang, Guomin; Cao, Shurui; Zhang, Lei; Tang, Bobin; Mu, Zhaode
2017-12-01
An analytical method was established for the rapid detection of antibiotic growth promoters (AGPs) in bovine muscle, and bovine blood and bovine urine, using ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). After the addition of an aqueous solution of EDTA-Na 2 , the pH of bovine urine samples was directly adjusted to 5.2 by acetic acid-ammonium acetate and purified by HLB solid-phase extraction cartridge; bovine muscle and bovine blood samples processing were extracted with acetonitrile (ACN) and ACNwater (90:10; v/v) without any purification step. The samples were then centrifuged, concentrated and analysed by UPLC-MS/MS on an ACQUITY UPLC® BEH C18 column using gradient elution. The developed method was validated and mean recovery percentages at three spiked levels were 74-119%, 76-115% and 76-119%, respectively, in bovine muscle, bovine blood, and bovine urine. The relative standard deviation (RSD) ranged from 1.0% to 14.7% in spiked bovine muscle, bovine blood and bovine urine. The limits of detection (LOD) of all analytes were in the ranges 0.11-3.82 µg kg -1 , 0.10-2.49 µg kg -1 and 0.06-4.53 µg kg -1 in bovine muscle, bovine blood, and bovine urine, respectively. The method was sensitive, accurate and was applied to monitor real samples. To the best of our knowledge, this is first method available for simultaneous determination of several classes of APGs in bovine muscle, and bovine blood and bovine urine.
Dib, Josef; Mongongu, Cynthia; Buisson, Corinne; Molina, Adeline; Schänzer, Wilhelm; Thuss, Uwe; Thevis, Mario
2017-01-01
The development of new therapeutics potentially exhibiting performance-enhancing properties implicates the risk of their misuse by athletes in amateur and elite sports. Such drugs necessitate preventive anti-doping research for consideration in sports drug testing programmes. Hypoxia-inducible factor (HIF) stabilizers represent an emerging class of therapeutics that allows for increasing erythropoiesis in patients. BAY 85-3934 is a novel HIF stabilizer, which is currently undergoing phase-2 clinical trials. Consequently, the comprehensive characterization of BAY 85-3934 and human urinary metabolites as well as the implementation of these analytes into routine doping controls is of great importance. The mass spectrometric behaviour of the HIF stabilizer drug candidate BAY 85-3934 and a glucuronidated metabolite (BAY-348) were characterized by electrospray ionization-(tandem) mass spectrometry (ESI-MS(/MS)) and multiple-stage mass spectrometry (MS n ). Subsequently, two different laboratories established different analytical approaches (one each) enabling urine sample analyses by employing either direct urine injection or solid-phase extraction. The methods were cross-validated for the metabolite BAY-348 that is expected to represent an appropriate target analyte for human urine analysis. Two test methods allowing for the detection of BAY-348 in human urine were applied and cross-validated concerning the validation parameters specificity, linearity, lower limit of detection (LLOD; 1-5 ng/mL), ion suppression/enhancement (up to 78%), intra- and inter-day precision (3-21%), recovery (29-48%), and carryover. By means of ten spiked test urine samples sent blinded to one of the participating laboratories, the fitness-for-purpose of both assays was provided as all specimens were correctly identified applying both testing methods. As no post-administration study samples were available, analyses of authentic urine specimens remain desirable. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Pastor-Belda, M; Fernández-García, A J; Campillo, N; Pérez-Cárceles, M D; Motas, M; Hernández-Córdoba, M; Viñas, P
2017-08-04
Glyoxal (GO) and methylglyoxal (MGO) are α-oxoaldehydes that can be used as urinary diabetes markers. In this study, their levels were measured using a sample preparation procedure based on salting-out assisted liquid-liquid extraction (SALLE) and dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography-mass spectrometry (GC-MS). The effect of the derivatization reaction with 2,3-diaminonaphthalene, the addition of acetonitrile and sodium chloride to urine, and the DLLME step using the acetonitrile extract as dispersant solvent and carbon tetrachloride as extractant solvent were carefully optimized. Quantification was performed by the internal standard method, using 5-bromo-2-chloroanisole. The intraday and interday precisions were lower than 6%. Limits of detection were 0.12 and 0.06ngmL -1 , and enrichment factors 140 and 130 for GO and MGO, respectively. The concentrations of these α-oxoaldehydes in urine were between 0.9 and 35.8ngg -1 levels (creatinine adjusted). A statistical comparison of the analyte contents of urine samples from non-diabetic and diabetic patients pointed to significant differences (P=0.046, 24 subjects investigated), particularly regarding MGO, which was higher in diabetic patients. The novelty of this study compared with previous procedures lies in the treatment of the urine sample by SALLE based on the addition of acetonitrile and sodium chloride to the urine. The DLLME procedure is performed with a sedimented drop of the extractant solvent, without a surfactant reagent, and using acetonitrile as dispersant solvent. Separation of the analytes was performed using GC-MS detection, being the analytes unequivocal identified. The proposed procedure is the first microextraction method applied to the analysis of urine samples from diabetic and non-diabetic patients that allows a clear differentiation between both groups using a simple analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Fernandez-Torres, R; Consentino, M Olías; Lopez, M A Bello; Mochon, M Callejon
2010-05-15
A new, accurate and sensitive reversed-phase high-performance liquid chromatography (RP-HPLC) as analytical method for the quantitative determination of 11 antibiotics (drugs) and the main metabolites of five of them present in human urine has been worked out, optimized and validated. The analytes belong to four different groups of antibiotics (sulfonamides, tetracyclines, penicillins and anphenicols). The analyzed compounds were sulfadiazine (SDI) and its N(4)-acetylsulfadiazine (NDI) metabolite, sulfamethazine (SMZ) and its N(4)-acetylsulfamethazine (NMZ), sulfamerazine (SMR) and its N(4)-acetylsulfamerazine (NMR), sulfamethoxazole (SMX), trimetroprim (TMP), amoxicillin (AMX) and its main metabolite amoxicilloic acid (AMA), ampicillin (AMP) and its main metabolite ampicilloic acid (APA), chloramphenicol (CLF), thiamphenicol (TIF), oxytetracycline (OXT) and chlortetracycline (CLT). For HPLC analysis, diode array (DAD) and fluorescence (FLD) detectors were used. The separation of the analyzed compounds was conducted by means of a Phenomenex Gemini C(18) (150mm x 4.6mm I.D., particle size 5microm) analytical column with LiChroCART LiChrospher C(18) (4mm x 4mm, particle size 5microm) guard column. Analyzed drugs were determined within 34min using formic acid 0.1% in water and acetonitrile in gradient elution mode as mobile phase. A linear response was observed for all compounds in the range of concentration studied. Two procedures were optimized for sample preparation: a direct treatment with methanol and acetonitrile and a solid phase extraction procedure using Bond Elut Plexa columns. The method was applied to the determination of the analytes in human urine from volunteers under treatment with different pharmaceutical formulations. This method can be successfully applied to routine determination of all these drugs in human urine samples.
Roca, M; Leon, N; Pastor, A; Yusà, V
2014-12-29
In this study we propose an analytical strategy that combines a target approach for the quantitative analysis of contemporary pesticide metabolites with a comprehensive post-target screening for the identification of biomarkers of exposure to environmental contaminants in urine using liquid chromatography coupled to high-resolution mass spectrometry (LC–HRMS). The quantitative method for the target analysis of 29 urinary metabolites of organophosphate (OP) insecticides, synthetic pyrethroids, herbicides and fungicides was validated after a previous statistical optimization of the main factors governing the ion source ionization and a fragmentation study using the high energy collision dissociation (HCD) cell. The full scan accurate mass data were acquired with a resolving power of 50,000 FWHM (scan speed, 2 Hz), in both ESI+ and ESI− modes, and with and without HCD-fragmentation. The method – LOQ was lower than 3.2 μg L−1 for the majority of the analytes. For post-target screening a customized theoretical database was built, for the identification of 60 metabolites including pesticides, PAHs, phenols, and other metabolites of environmental pollutants. For identification purposes, accurate exact mass with less than 5 ppm, and diagnostic ions including isotopes and/or fragments were used. The analytical strategy was applied to 20 urine sample collected from children living in Valencia Region. Eleven target metabolites were detected with concentrations ranging from 1.18 to 131 μg L−1. Likewise, several compounds were tentatively identified in the post-target analysis belonging to the families of phthalates, phenols and parabenes. The proposed strategy is suitable for the determination of target pesticide biomarkers in urine in the framework of biomonitoring studies, and appropriate for the identification of other non-target metabolites.
Meng, Liang; Zhu, Binling; Zheng, Kefang; Fu, Shanlin
2017-05-15
A novel microextraction technique based on ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction (UA-LDS-DLLME) had been applied for the determination of 4 designer benzodiazepines (phenazepam, diclazepam, flubromazepam and etizolam) in urine samples by gas chromatography- triple quadrupole mass spectrometry (GC-QQQ-MS). Ethyl acetate (168μL) was added into the urine samples after adjusting pH to 11.3. The samples were sonicated in an ultrasonic bath for 5.5min to form a cloudy suspension. After centrifugation at 10000rpm for 3min, the supernatant extractant was withdrawn and injected into the GC-QQQ-MS for analysis. Parameters affecting the extraction efficiency have been investigated and optimized by means of single factor experiment and response surface methodology (Box-Behnken design). Under the optimum extraction conditions, a recovery of 73.8-85.5% were obtained for all analytes. The analytical method was linear for all analytes in the range from 0.003 to 10μg/mL with the correlation coefficient ranging from 0.9978 to 0.9990. The LODs were estimated to be 1-3ng/mL. The accuracy (expressed as mean relative error MRE) was within ±5.8% and the precision (expressed as relative standard error RSD) was less than 5.9%. UA-LDS-DLLME technique has the advantages of shorter extraction time and is suitable for simultaneous pretreatment of samples in batches. The combination of UA-LDS-DLLME with GC-QQQ-MS offers an alternative analytical approach for the sensitive detection of these designer benzodiazepines in urine matrix for clinical and medico-legal purposes. Copyright © 2017 Elsevier B.V. All rights reserved.
Xiao, Ge; Saunders, David; Jones, Robert L.; Caldwell, Kathleen L.
2016-01-01
Quantification of 241Am in urine at low levels is important for assessment of individuals’ or populations’ accidental, environmental, or terrorism-related internal contamination, but no convenient, precise method has been established to rapidly determine these low levels. Here we report a new analytical method to measure 241Am as developed and validated at the Centers for Disease Control and Prevention (CDC) by means of the selective retention of Am from urine directly on DGA resin, followed by SF-ICP-MS detection. The method provides rapid results with a Limit of Detection (LOD) of 0.22 pg/L (0.028 Bq/L), which is lower than 1/3 of the C/P CDG for 241Am at 5 days post-exposure. The results obtained by this method closely agree with CDC values as measured by Liquid Scintillation Counting, and with National Institute of Standards Technology (NIST) Certified Reference Materials (CRM) target values. PMID:27375308
Xiao, Ge; Saunders, David; Jones, Robert L; Caldwell, Kathleen L
2016-07-01
Quantification of 241 Am in urine at low levels is important for assessment of individuals' or populations' accidental, environmental, or terrorism-related internal contamination, but no convenient, precise method has been established to rapidly determine these low levels. Here we report a new analytical method to measure 241 Am as developed and validated at the Centers for Disease Control and Prevention (CDC) by means of the selective retention of Am from urine directly on DGA resin, followed by SF-ICP-MS detection. The method provides rapid results with a Limit of Detection (LOD) of 0.22 pg/L (0.028 Bq/L), which is lower than 1/3 of the C/P CDG for 241 Am at 5 days post-exposure. The results obtained by this method closely agree with CDC values as measured by Liquid Scintillation Counting, and with National Institute of Standards Technology (NIST) Certified Reference Materials (CRM) target values.
Yoon, S; Pak, M-J; Park, S; Yoo, J; Ha, W-H; Jang, H-K; Kim, J K
2014-12-01
(32)P measurements of urine samples and internal dose assessments were conducted for workers in life science laboratories. A procedure for sample pre-treatment was established and validation was performed to exclude interference and to detect (32)P levels accurately. The detection conditions for Cherenkov radiation were evaluated and the accuracy of Cherenkov radiation measurements validated. The analytical and measurement procedures were applied to urine samples collected from 11 workers from life sciences laboratories. The results of the measurements generally indicated very low background radiation levels, but daily urine samples from two workers were above the minimum detectable activity. The (32)P concentrations for two of the workers were 29.3 ± 10.4 Bq•d(-1) and 24.1 ± 11.8 Bq•d(-1), respectively, at intake levels of 4.12 kBq and 2.61 kBq. The effective doses for these two workers were 4.6 μSv and 2.9 μSv. Overall, the results indicate very low levels of radioactivity, except for cases related to specific working conditions.
Schantz, Michele M; Benner, Bruce A; Heckert, N Alan; Sander, Lane C; Sharpless, Katherine E; Vander Pol, Stacy S; Vasquez, Y; Villegas, M; Wise, Stephen A; Alwis, K Udeni; Blount, Benjamin C; Calafat, Antonia M; Li, Zheng; Silva, Manori J; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G; Sjödin, Andreas
2015-04-01
Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers' Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants.
Schantz, Michele M.; Benner, Bruce A.; Heckert, N. Alan; Sander, Lane C.; Sharpless, Katherine E.; Vander Pol, Stacy S.; Vasquez, Y.; Villegas, M.; Wise, Stephen A.; Alwis, K. Udeni; Blount, Benjamin C.; Calafat, Antonia M.; Li, Zheng; Silva, Manori J.; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G.; Sjödin, Andreas
2016-01-01
Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers’ Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers’ Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants. PMID:25651899
Liou, Saou-Hsing; Yang, Gordon C C; Wang, Chih-Lung; Chiu, Yu-Han
2014-07-30
This 5-month study contains two parts: (1) to monitor the concentrations of 11 phthalate esters metabolites (PAEMs) and two beta-agonists in human urine samples collected from a small group of consented participants including 16 females and five males; and (2) to analyze the residues of phthalate esters (PAEs) and beta-agonists in various categories of drinking water consumed by the same group of subjects. Each category of human urine and drinking water had 183 samples of its own. The analytical results showed that nine PAEMs were detected in human urine and eight PAEs were detected in drinking water samples. It was found that average concentrations of PAEMs increased as the age increased, but no significant difference between sexes. Further, using the principal component analysis, the loadings of age effect were found to be two times greater than that of gender effect in terms of four DEHP metabolites. Regarding beta-agonists of concern (i.e., ractopamine and salbutamol), they were neither detected in human urine nor drinking water samples in this study. Copyright © 2014 Elsevier B.V. All rights reserved.
Urinary free cortisol and cortisone excretion in healthy individuals: influence of water loading.
Fenske, Martin
2006-11-01
The influence of water loading on urinary excretion of free cortisol and cortisone was investigated in healthy men. The results were as follows: water loading tests (intake of 0.25-1.5 L) in a single individual showed that a water load of 1.5 L reliably increased the excretion of urine, free cortisol and cortisone (p < 0.01). Regression analyses gave significant correlations of urine volume with free cortisol and free cortisone, and of free cortisol and free cortisone. Corresponding results were obtained when water loading tests were performed in males who ingested 1.5 L of water (n = 8): the excretion of urine, free cortisol and free cortisone were significantly augmented; correlated was urine volume with free cortisol and free cortisone, and free cortisol with free cortisone. In a third set of tests, volunteers collected one 5 h urine (10:00-15:00 h) after the intake of 3 x 0.1 or 0.5 L at 11:00, 12:00 and 14:00 h. Excretion of urine, free cortisol and free cortisone in males of the low water loading group (3 x 0.1 L) was 0.59 mL/min, and 8.2 or 15.0 microg/5 h; corresponding values in individuals ingesting 3 x 0.5 L of water were 1.5 mL/min (p < 0.01), 12.3 microg/5 h (p > 0.05) and 26.3 microg/5 h (p < 0.02). In summary, urinary free cortisol and cortisone excretion in healthy men depends on urine volume, especially during water diuresis. Thus, interpretation of free cortisol and especially of free cortisone excretion is only possible if subjects strictly control their fluid intake and if urine volume is considered an important pre-analytical parameter-otherwise, interpretation of urinary free cortisol results is difficult and of urinary free cortisone data remains tenuous at best.
SPECIATION OF ARSENIC IN EXPOSURE ASSESSMENT MATRICES
The speciaton of arsenic in water, food and urine are analytical capabilities which are an essential part in arsenic risk assessment. The cancer risk associated with arsenic has been the driving force in generating the analytical research in each of these matrices. This presentat...
Zhou, Hui-Ting; Chen, Hsin-Chang; Ding, Wang-Hsien
2018-02-20
An analytical method that utilizes isotope-dilution ultrahigh-performance liquid chromatography coupled with hybrid quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS or called UHPLC-HRMS) was developed, and validated to be highly precise and accurate for the detection of nine parabens (methyl-, ethyl-, propyl-, isopropyl-, butyl-, isobutyl-, pentyl-, hexyl-, and benzyl-parabens) in human urine samples. After sample preparation by ultrasound-assisted emulsification microextraction (USAEME), the extract was directly injected into UHPLC-HRMS. By using negative electrospray ionization in the multiple reaction monitoring (MRM) mode and measuring the peak area ratios of both the natural and the labeled-analogues in the samples and calibration standards, the target analytes could be accurately identified and quantified. Another use for the labeled-analogues was to correct for systematic errors associated with the analysis, such as the matrix effect and other variations. The limits of quantitation (LOQs) were ranging from 0.3 to 0.6 ng/mL. High precisions for both repeatability and reproducibility were obtained ranging from 1 to 8%. High trueness (mean extraction recovery, or called accuracy) ranged from 93 to 107% on two concentration levels. According to preliminary results, the total concentrations of four most detected parabens (methyl-, ethyl-, propyl- and butyl-) ranged from 0.5 to 79.1 ng/mL in male urine samples, and from 17 to 237 ng/mL in female urine samples. Interestingly, two infrequently detected pentyl- and hexyl-parabens were found in one of the male samples in this study. Copyright © 2017 Elsevier B.V. All rights reserved.
Scheidweiler, Karl B.; Desrosiers, Nathalie A.; Huestis, Marilyn A.
2012-01-01
Background Cannabis is the most commonly abused drug of abuse and is commonly quantified during urine drug testing. We conducted a controlled drug administration studies investigating efficacy of urinary cannabinoid glucuronide metabolites for documenting recency of cannabis intake and for determining stability of urinary cannabinoids. Methods A liquid chromatography tandem mass spectrometry method was developed and validated quantifying Δ9-tetrahydrocannabinol (THC), 11-hydroxy-THC (11-OH-THC), 11-nor-9-carboxy-THC (THCCOOH), cannabidiol, cannabinol, THC-glucuronide and THCCOOH-glucuronide in 0.5 ml human urine via supported-liquid extraction. Chromatography was performed on an Ultra Biphenyl column with a gradient of 10 mmol/l ammonium acetate, pH 6.15 and 15% methanol in acetonitrile at 0. 4ml/min. Analytes were monitored by positive and negative mode electrospray ionization and multiple reaction monitoring mass spectrometry. Results Linear ranges were 0.5–50 ng/ml for THC-glucuronide, 1–100 ng/ml for THCCOOH, 11-OH-THC and cannabidiol, 2–100 ng/ml for THC and cannabinol, and 5–500 ng/ml for THCCOOH-glucuronide (R2>0.99). Mean extraction efficiencies were 34–73% with analytical recovery (bias) 80.5–118.0% and total imprecision 3.0–10.2% coefficient of variation. Conclusion This method simultaneously quantifies urinary cannabinoids and phase II glucuronide metabolites, and enables evaluation of urinary cannabinoid glucuronides for documenting recency of cannabis intake and cannabinoid stability. The assay is applicable for routine urine cannabinoid testing. PMID:22771478
Zhou, Ting; Zhao, Ting; Cheng, Qing; Liu, Shan; Xu, Ling; Tan, Wen
2014-07-01
A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of R-bambuterol and its active metabolite R-terbutaline in human plasma and urine was established. The inhibition for the biotransformation of R-bambuterol in plasma was fully investigated. Plasma samples were prepared on ice and neostigmine metilsulfate added as a cholinesterase inhibitor immediately after sample collection. All samples were extracted with ethyl acetate and separated on a C₁₈ column under gradient elution with a mobile phase consisting of methanol and water containing 5 mm ammonium acetate at a flow rate of 0.6 mL/min. The analytes were detected by an API 4000 tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. The established method was highly sensitive with the lower limit of quantification (LLOQ) of 10.00 pg/mL for each analyte in plasma. In urine samples, the LLOQs were 20.00 and 500.0 pg/mL for R-bambuterol and R-terbutaline, respectively. The intra- and inter-day precisions were <12.7 and <8.6% for plasma and urine, respectively. The analytical runtime within 6.0 min per sample made this method suitable for high-throughput determination. The validated method has been successfully applied to the human pharmacokinetic study of R-bambuterol involving 10 healthy volunteers. Copyright © 2013 John Wiley & Sons, Ltd.
Draisci, Rosa; Palleschi, Luca; Ferretti, Emanuele; Lucentini, Luca; delli Quadri, Fernanda
2003-06-15
A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for confirmatory analysis of 17beta-boldenone (17beta-BOL), 17alpha-boldenone (17alpha-BOL) and androsta-1,4-diene-3,17-dione (ADD) in bovine urine was developed. [2H(2)]17beta-Testosterone (17beta-T-d(2)) was used as the internal standard. Sample preparation involved enzymatic hydrolysis and purification on a C(18) solid-phase extraction column. Chromatographic separation of the analytes was obtained using an RP-C(18) HPLC column. LC-MS-MS detection was carried out with an atmospheric pressure chemical ionisation (APCI) source equipped with a heated nebulizer (HN) interface operating in the positive ion mode. For unambiguous hormone confirmation, three analyte precursor-product ion combinations were monitored during multiple-reaction monitoring (MRM) LC-MS-MS analysis. Overall recovery (%), repeatability (relative standard deviations, RSD, %) and within-laboratory reproducibility (RSD, %) ranged from 92.2 to 97.7%, from 6.50 to 2.94% and from 13.50 to 5.04%, respectively, for all analytes. The limit of quantification in bovine urine was 0.20 ng ml(-1) for 17beta-BOL and ADD and 0.50 ng ml(-1) for 17alpha-BOL. The validated method was successfully applied for determination of 17beta-BOL, 17alpha-BOL and ADD in a large number of bovine urine samples collected within the national Official Residue Control Program.
Hanna, C P; Tyson, J F; McIntosh, S
1993-08-01
A method has been developed for the determination of inorganic arsenic [As(III) and As(V)] and its organic metabolites (monomethylarsenic and dimethylarsenic) in urine by flow-injection hydride generation atomic absorption spectrometry. The nontoxic seafood-derived arsenobetaine and arsenocholine species were first separated by a solid-phase extraction procedure. The remaining sample was digested with a mixture of nitric and sulfuric acids and potassium dichromate, followed by attack with hydrogen peroxide. The resulting As(V) was reduced to As(III) with potassium iodide in hydrochloric acid before injection into the flow-injection manifold. The percentage analytical recoveries (mean +/- 95% confidence interval) of various arsenic species added to a urine specimen at 250 micrograms/L were 108 +/- 2, 112 +/- 11, 104 +/- 7, and 95 +/- 5 for As(III), As(V), monomethylarsenic, and dimethylarsenic, respectively. For the determination of arsenic in Standard Reference Material 2670 (toxic metals in human urine), results agreed with the certified value (480 +/- 100 micrograms/L). Analyses of samples for the Centre de Toxicologie du Quebec, containing seafood-derived species, demonstrated the viability of the separation procedure. Detection limits were between 0.1 and 0.2 microgram/L in the solution injected into the manifold, and precision at 10 micrograms/L was between 2% and 3% (CV). These preliminary results show that the method might be applicable to determinations of arsenic in a range of clinical urine specimens.
Davis, Mark D; Wade, Erin L; Restrepo, Paula R; Roman-Esteva, William; Bravo, Roberto; Kuklenyik, Peter; Calafat, Antonia M
2013-06-15
Organophosphate and pyrethroid insecticides and phenoxyacetic acid herbicides represent important classes of pesticides applied in commercial and residential settings. Interest in assessing the extent of human exposure to these pesticides exists because of their widespread use and their potential adverse health effects. An analytical method for measuring 12 biomarkers of several of these pesticides in urine has been developed. The target analytes were extracted from one milliliter of urine by a semi-automated solid phase extraction technique, separated from each other and from other urinary biomolecules by reversed-phase high performance liquid chromatography, and detected using tandem mass spectrometry with isotope dilution quantitation. This method can be used to measure all the target analytes in one injection with similar repeatability and detection limits of previous methods which required more than one injection. Each step of the procedure was optimized to produce a robust, reproducible, accurate, precise and efficient method. The required selectivity and sensitivity for trace-level analysis (e.g., limits of detection below 0.5ng/mL) was achieved using a narrow diameter analytical column, higher than unit mass resolution for certain analytes, and stable isotope labeled internal standards. The method was applied to the analysis of 55 samples collected from adult anonymous donors with no known exposure to the target pesticides. This efficient and cost-effective method is adequate to handle the large number of samples required for national biomonitoring surveys. Published by Elsevier B.V.
Poupeau, Céline; Roland, Christel; Bussières, Jean-François
2016-01-01
There is increasing evidence that traces of hazardous drugs occur in the urine of health care professionals who are exposed to these drugs. To review the scientific literature regarding urinary monitoring of health care professionals exposed to antineoplastic drugs through their work. A search of PubMed using the Medical Subject Headings 'occupational exposure' and 'antineoplastic agents' and of Google Scholar using the terms 'antineoplastic', 'urine', and 'occupational exposure'. The analysis covered all articles in English or French pertaining to health care professionals exposed to hazardous drugs in the workplace, published from January 1, 2010, to December 31, 2015. Articles that did not discuss the results of urine tests and those concerning veterinarians, as well as literature reviews, editorials, letters to the editor, and conference abstracts, were excluded. Twenty-four articles were retained. The studies were conducted in 52 health care institutions in 7 countries. They included 826 workers exposed to hazardous drugs and 175 controls, specifically nurses ( n = 16 studies), pharmacists ( n = 10), pharmacy technicians ( n = 8), physicians ( n = 7), health care aides ( n = 2), and others ( n = 8). Various analytical methods were used to quantify the presence of 13 hazardous drugs, primarily cyclophosphamide ( n = 16 studies), platinum-based drugs ( n = 7), and alpha-fluoro-beta-alanine, a urine metabolite derived from 5-fluorouracil ( n = 3). The proportion of workers with positive results ranged from 0% ( n = 10 studies) to 100% ( n = 4). Considering only those studies that allowed calculation of the rate of workers with at least one positive urine sample ( n = 23), the total proportion was 21% (173/809 workers, for all methods and drugs combined). Twenty-four studies on urine monitoring were conducted in 7 countries between 2010 and 2015. In several studies, no traces of drugs were detected in urine.
Schmidt, Kathrin S; Mankertz, Joachim
2018-06-01
A sensitive and robust LC-MS/MS method allowing the rapid screening and confirmation of selective androgen receptor modulators in bovine urine was developed and successfully validated according to Commission Decision 2002/657/EC, chapter 3.1.3 'alternative validation', by applying a matrix-comprehensive in-house validation concept. The confirmation of the analytes in the validation samples was achieved both on the basis of the MRM ion ratios as laid down in Commission Decision 2002/657/EC and by comparison of their enhanced product ion (EPI) spectra with a reference mass spectral library by making use of the QTRAP technology. Here, in addition to the MRM survey scan, EPI spectra were generated in a data-dependent way according to an information-dependent acquisition criterion. Moreover, stability studies of the analytes in solution and in matrix according to an isochronous approach proved the stability of the analytes in solution and in matrix for at least the duration of the validation study. To identify factors that have a significant influence on the test method in routine analysis, a factorial effect analysis was performed. To this end, factors considered to be relevant for the method in routine analysis (e.g. operator, storage duration of the extracts before measurement, different cartridge lots and different hydrolysis conditions) were systematically varied on two levels. The examination of the extent to which these factors influence the measurement results of the individual analytes showed that none of the validation factors exerts a significant influence on the measurement results.
Micro-flow injection system for the urinary protein assay.
Nishihama, Syouhei; Imabayashi, Hisano; Matoba, Tomoko; Toya, Chika; Watanabe, Kosuke; Yoshizuka, Kazuharu
2008-02-15
A urinary protein assay has been investigated, employing a micro-flow injection analysis (muFIA) combined with an adsorptive separation of protein from analyte. The adsorptive separation part of protein in the artificial urine with ceramic hydroxyapatite is integrated on the muFIA chip, since the interference of other components coexisting in urine occurs in the conventional FIA system. The typical FI peak can be obtained following the adsorption-elution process of the protein prior to the detection, and the protein concentration in artificial urine can be quantitatively determined.
Simultaneous Analysis of Seven Biomarkers of Oxidative Damage to Lipids, Proteins, and DNA in Urine.
Martinez, Maria P; Kannan, Kurunthachalam
2018-06-05
The determination of oxidative stress biomarkers (OSBs) is useful for the assessment of health status and progress of diseases in humans. Whereas previous methods for the determination of OSBs in urine were focused on a single marker, in this study, we present a method for simultaneous determination of biomarkers of oxidative damage to lipids, proteins, and DNA. 2,4-Dinitrophenylhydrazine (DNPH) derivatization followed by solid phase extraction (SPE) and high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) allowed the determination of 8-hydroxy-2'-deoxyguanosine (8-OHdG), o- o'-dityrosine (diY), malondialdehyde (MDA), and four F 2 -isoprostane isomers: 8-iso-prostaglandinF 2α (8-PGF 2α ), 11β-prostaglandinF 2α (11-PGF 2α ), 15( R)-prostaglandinF 2α (15-PGF 2α ), and 8-iso,15( R)-prostaglandinF 2α (8,15-PGF 2α ) in urine. Derivatization with DNPH and SPE was optimized to yield greater sensitivity and selectivity for the analysis of target chemicals. The limits of detection of target analytes in urine were below 30 pg mL -1 . The assay intra- and interday variability was below 16% of the relative standard deviation, and the recoveries of target chemicals spiked into synthetic urine were near 100%. The method was applied to the analysis of 21 real urine samples, and the analytes were found at a detection frequency of 85% for 8-PGF 2α and 15-PGF 2α , 71% for 11-PGF 2α , 81% for 8,15-PGF 2α , and 100% for diY, 8-OHdG, and MDA. This method offers simultaneous determination of multiple OSBs of different molecular origin in urine samples selectively with high accuracy and precision.
De, Prithwiraj; Amin, Anita G.; Valli, Eloise; Perkins, Mark D.; McNeil, Michael; Chatterjee, Delphi
2015-01-01
Globally, tuberculosis is slowly declining each year and it is estimated that 37 million lives were saved between 2000 and 2013 through effective diagnosis and treatment. Currently, diagnosis relies on demonstration of the bacteria, Mycobacterium tuberculosis (Mtb), in clinical specimens by serial sputum microscopy, culture and molecular testing. Commercial immunoassay lateral flow kits developed to detect Mtb lipoglycan lipoarabinomannan (LAM) in urine as a marker of active TB exhibit poor sensitivity, especially in immunocompetent individuals, perhaps due to low abundance of the analyte. Our present study was designed to develop methods to validate the presence of LAM in a quantitative fashion in human urine samples obtained from culture-confirmed TB patients. Herein we describe, a consolidated approach for isolating LAM from the urine and quantifying D-arabinose as a proxy for LAM, using Gas Chromatography/Mass Spectrometry. 298 urine samples obtained from a repository were rigorously analyzed and shown to contain varying amounts of LAM-equivalent ranging between ~10–40 ng/mL. To further substantiate that D-arabinose detected in the samples originated from LAM, tuberculostearic acid, the unique 10-methyloctadecanoic acid present at the phosphatidylinositol end of LAM was also analyzed in a set of samples and found to be present confirming that the D-arabinose was indeed derived from LAM. Among the 144 samples from culture-negative TB suspects, 30 showed presence of D-arabinose suggesting another source of the analyte, such as disseminated TB or from non-tuberculosis mycobacterium. Our work validates that LAM is present in the urine samples of culture-positive patients in small but readily detectable amounts. The study further substantiates LAM in urine as a powerful biomarker for active tuberculosis. PMID:26633829
Kuwayama, Kenji; Miyaguchi, Hajime; Yamamuro, Tadashi; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki
2016-07-01
In forensic drug testing, it is important to immediately take biological specimens from suspects and victims to prove their drug intake. We evaluated the effectiveness of saliva and fingerprints as alternative specimens to urine and blood in terms of ease of sampling, drug detection sensitivity, and drug detection periods for each specimen type. After four commercially available pharmaceutical products were administered to healthy subjects, each in a single dose, their urine, blood, saliva, and fingerprints were taken at predetermined sampling times over approximately four weeks. Fourteen analytes (the administered drugs and their main metabolites) were extracted from each specimen using simple pretreatments, such as dilution and deproteinization, and were analyzed using liquid chromatography/mass spectrometry (LC/MS). Most of the analytes were detected in saliva and fingerprints, as well as in urine and blood. The time-courses of drug concentrations were similar between urine and fingerprints, and between blood and saliva. Compared to the other compounds, the acidic compounds, for example ibuprofen, acetylsalicylic acid, were more difficult to detect in all specimens. Acetaminophen, dihydrocodeine, and methylephedrine were detected in fingerprints at later sampling times than in urine. However, a relationship between the drug structures and their detection periods in each specimen was not found. Saliva and fingerprints could be easily sampled on site without using special techniques or facilities. In addition, fingerprints could be immediately analyzed after simple and rapid treatment. In cases where it would be difficult to immediately obtain urine and blood, saliva and fingerprints could be effective alternative specimens for drug testing. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Urine oxalate biological variation in patients with primary hyperoxaluria.
Clifford-Mobley, Oliver; Sjögren, Anna; Lindner, Elisabeth; Rumsby, Gill
2016-08-01
Hyperoxaluria is a well-recognised risk factor for urolithiasis and patients with primary hyperoxaluria (PH) gradually build up calcium oxalate deposits leading to chronic kidney disease. Efforts to improve treatment for PH have focused on reducing urine oxalate excretion and thus decreasing lithogenesis. To determine the efficacy of treatments designed to alter a biochemical parameter it is necessary to know the biological and analytical variation of that parameter. In this study, we estimated the intra-individual biological variation of urine oxalate excretion in patients with PH, and from this determined what would constitute a significant change in the form of a reference change value (RCV). Each patient collected four 24-h urines on consecutive weeks. The intra-individual biological variation of oxalate excretion calculated from these samples ranged from 0 to 36 % with a mean of 14 %. The corresponding RCVs were 4-84 % with a mean of 32 %. This result implies that, on average, a reduction of almost one-third in urine oxalate excretion is required to prove an effect from treatment. The wide range of biological variation between individuals may reflect other, as yet unknown, determinants of oxaluria in PH, as well as inaccuracies in urine collection. The data suggest that it is more appropriate to use individual RCVs established prior to treatment to determine its efficacy: a relatively small fall in urine oxalate excretion may be outside the biological variation of some patients but not of others.
Laboratory and clinical evaluation of on-site urine drug testing.
Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter
2014-11-01
Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.
Lee, HyungJae; Choi, Mihye; Hwang, Sang-Hyun; Cho, Youngnam
2018-01-01
Purpose: As human papillomavirus (HPV) is primarily responsible for the development of cervical cancer, significant efforts have been devoted to develop novel strategies for detecting and identifying HPV DNA in urine. The analysis of target DNA sequences in urine offers a potential alternative to conventional methods as a non-invasive clinical screening and diagnostic assessment tool for the detection of HPV. However, the lack of efficient approaches to isolate and directly detect HPV DNA in urine has restricted its potential clinical use. In this study, we demonstrated a novel approach of using polyethylenimine-conjugated magnetic polypyrrole nanowires (PEI-mPpy NWs) for the extraction, identification, and PCR-free colorimetric detection of high-risk strains of HPV DNA sequences, particularly HPV-16 and HPV-18, in urine specimens of cervical cancer patients. Materials and Methods: We fabricated and characterized polyethylenimine-conjugated magnetic nanowires (PEI/mPpy NWs). PEI/mPpy NWs-based HPV DNA isolation and detection strategy appears to be a cost-effective and practical technology with greater sensitivity and accuracy than other urine-based methods. Results: The analytical and clinical performance of PEI-mPpy NWs was evaluated and compared with those of cervical swabs, demonstrating a superior type-specific concordance rate of 100% between urine and cervical swabs, even when using a small volume of urine (300 µL). Conclusion: We envision that PEI-mPpy NWs provide substantive evidence for clinical diagnosis and management of HPV-associated disease with their excellent performance in the recovery and detection of HPV DNA from minimal amounts of urine samples. PMID:29290816
Validation of an ELISA Synthetic Cannabinoids Urine Assay
Barnes, Allan J.; Spinelli, Eliani; Young, Sheena; Martin, Thomas M.; Klette, Kevin L.; Huestis, Marilyn A.
2015-01-01
Background Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug testing laboratories. We evaluated performance of the NMS JWH-018 direct ELISA kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. Materials/ Methods The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was utilized to screen 2492 urine samples with 5 and 10µg/L cutoffs. A fully validated LC-MS/MS method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25 and ±50% of cutoffs determined intra- and inter-plate imprecision around proposed cutoffs. Result The immunoassay was linear from 1–500µg/L with intra- and inter-plate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, co-administered drugs, over-the-counter medications or structurally similar compounds, and 19 of 73 individual, synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4% and 97.6% and 71.6%, 99.7% and 96.4%, with the 5 and 10µg/L urine cutoffs, respectively. Conclusion This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5µg/L urine cutoff. PMID:25706046
Abushareeda, Wadha; Vonaparti, Ariadni; Saad, Khadija Al; Almansoori, Moneera; Meloug, Mbarka; Saleh, Amal; Aguilera, Rodrigo; Angelis, Yiannis; Horvatovich, Peter L; Lommen, Arjen; Alsayrafi, Mohammed; Georgakopoulos, Costas
2018-03-20
The aim of this paper is to present the development and validation of a high-resolution full scan (HR-FS) electrospray ionization (ESI) liquid chromatography coupled to quadrupole Orbitrap mass spectrometer (LC/Q/Orbitrap MS) platform for the screening of prohibited substances in human urine according to World Antidoping Agency (WADA) requirements. The method was also validated for quantitative analysis of six endogenous steroids (epitestosterone, testosterone, 5α-dihydrotestosterone, dehydroepiandrosterone, androsterone and etiocholanolone) in their intact sulfates form. The sample preparation comprised a combination of a hydrolyzed urine liquid-liquid extraction and the dilute & shoot addition of original urine in the extracted aliquot. The HR-FS MS acquisition mode with Polarity Switching was applied in combination of the Quadrupole-Orbitrap mass filter. The HR-FS acquisition of analytical signal, for known and unknown small molecules, allows the inclusion of all analytes detectable with LC-MS for antidoping investigations to identify the use of known or novel prohibited substances and metabolites after electronic data files' reprocessing. The method has been validated to be fit-for-purpose for the antidoping analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Alshogran, Osama Y.; Ocque, Andrew J.; Leblond, François A.; Pichette, Vincent; Nolin, Thomas D.
2016-01-01
A simple and rapid liquid chromatographic–tandem mass spectrometric method has been developed and validated for the enantiospecific determination of R- and S-warfarin in human urine. Warfarin enantiomers were extracted from urine using methyl tert-butyl ether. Chromatographic separation of warfarin enantiomers and the internal standard d5-warfarin was achieved using a Astec Chirobiotic V column with gradient mobile phase at a flow rate of 400 µL/min over 10 min. Detection was performed on a TSQ Quantum Ultra triple quadrupole mass spectrometer equipped with a heated electrospray ionization source. Analytes were detected in negative ionization mode using selected reaction monitoring. Calibration curves were linear with a correlation coefficient of ≥0.996 for both enantiomers over a concentration range of 5–500 ng/mL. The intra- and interday accuracy and precision for both analytes were within ±9.0%. Excellent extraction efficiency and negligible matrix effects were observed. The applicability of the method was demonstrated by successful measurement of warfarin enantiomers in urine of patients with kidney disease. The method is simple, accurate and reproducible and is currently being used to support warfarin pharmacokinetic studies. PMID:26657732
Tan, Susanna K; Sahoo, Malaya K; Milligan, Stephen B; Taylor, Nathaniel; Pinsky, Benjamin A
2017-10-01
Detection of Zika virus (ZIKV) RNA in urine is of increasing interest for the diagnosis of ZIKV infection. Pre-analytical variables can significantly impact the stability of RNA in urine. To determine optimal specimen processing protocols that would maximize detection of ZIKV RNA in urine by real-time, reverse transcriptase PCR, we investigated the effect of temperature, initial ZIKV concentration, use of nucleic acid stabilizers, and time on ZIKV RNA levels. Urine samples from healthy donors were spiked with ZIKV using the Exact Diagnostics ® ZIKV Verification Panel, a commercially available panel composed of heat-inactivated ZIKV, at concentrations of 5.0 log 10 copies/mL (ZIKV-high) and 4.0 log 10 copies/mL (ZIKV-low). Samples were stored at room temperature, 4°C, or -80°C and frozen aliquots were exposed to no stabilizer (urine), Buffer ATL (Qiagen, Germantown, MD), or DNA/RNA Shield (Zymo Research, Irvine, CA). ZIKV RNA levels in urine declined steadily at room temperature, though was not significant by 48h (ZIKV-high, p=0.09; ZIKV-low, p=0.20). ZIKV RNA titers were consistently higher when stored at 4°C, suggesting that storage at 4°C can slow the progression of RNA degradation. Freezing urine samples at -80°C resulted in a significant loss of detectable ZIKV RNA in the ZIKV-low group. ZIKV RNA was detected in 5/6 replicates at 3days, 1/6 replicates at 10days, and 1/3 replicates at 30days, with findings reproducible on repeat testing. Presence of either nucleic acid stabilizer in urine corrected this effect, and resulted in recovery of ZIKV RNA in all replicates. Use of a nucleic acid stabilizer in the ZIKV-high group did not add incremental benefit for the detection or quantitation of ZIKV RNA. ZIKV RNA is prone to degradation in urine with loss of detectable virus even when specimens are frozen at -80°C for 10days. Detection of ZIKV-positive urine samples, particularly those containing low ZIKV titers may be aided with the addition of a nucleic acid stabilizer during urine specimen processing. Copyright © 2017. Published by Elsevier B.V.
Aizpurua-Olaizola, Oier; Zarandona, Iratxe; Ortiz, Laura; Navarro, Patricia; Etxebarria, Nestor; Usobiaga, Aresatz
2017-04-01
A high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) method for simultaneous quantification of Δ9-tetrahydrocannabinol (THC), its two metabolites 11-hydroxy-Δ9-tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH), and four additional cannabinoids (cannabidiol (CBD), cannabigerol (CBG), tetrahydrocannabivarin (THCV), and cannabinol (CBN)) in 1 mL of human urine and plasma was developed and validated. The hydrolysis process was studied to ensure complete hydrolysis of glucuronide conjugates and the extraction of a total amount of analytes. Initially, urine and plasma blank samples were spiked with THC-COOH-glucuronide and THC-glucuronide, and four different pretreatment methods were compared: hydrolysis-free method, enzymatic hydrolysis with Escherichia Coli β-glucuronidase, alkaline hydrolysis with 10 M NaOH, and enzyme-alkaline tandem hydrolysis. The last approach assured the maximum efficiencies (close to 100%) for both urine and plasma matrices. Regarding the figures of merit, the limits of detection were below 1 ng/mL for all analytes, the accuracy ranged from 84% to 115%, and both within-day and between-day precision were lower than 12%. Finally, the method was successfully applied to real urine and plasma samples from cannabis users. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Correia, A; Galesio, M; Santos, H; Rial-Otero, R; Lodeiro, C; Oehmen, A; Conceição, Antonio C L; Capelo, J L
2007-05-15
Two advanced oxidation processes (AOPs), based on high-intensity focused ultrasound (HIFU), namely, KMnO(4)/HCl/HIFU and H(2)O(2)/HCl/HIFU are studied and compared for the determination of toxic arsenic in human urine [As(III)+As(V)+MMA+DMA] by flow-injection hydride-generation atomic absorption spectrometry (FI-HG-AAS). The KMnO(4)/HCl/HIFU procedure was found to be adequate for organic matter degradation in human urine. l-cysteine (letra minuscula) was used for As reduction to the trivalent state. The new procedure was assessed with seven urines certified in different As species. Results revealed that with KMnO(4)/HCl/HIFU plus l-cysteine the toxic arsenic can be accurately measured in human urine whilst the H(2)O(2)/HCl/HIFU procedure underestimates toxic As. DMA and MMA degradation in urine were observed, due to the effects of the ultrasonic field. Recoveries for As(III), As(V), MMA and DMA were within the certified ranges. Arsenobetaine was not degraded by the AOPs. The new procedure adheres well to the principles of analytical minimalism: (i) low reagent consumption, (ii) low reagent concentration, (iii) low waste production and (iv) low amount of time required for sample preparation and analysis.
Peng, Zhangxiao; Zhang, Qian; Mao, Ziming; Wang, Jie; Liu, Chunying; Lin, Xuejing; Li, Xin; Ji, Weidan; Fan, Jianhui; Wang, Maorong; Su, Changqing
2017-11-15
Much evidence suggested that quantitative analysis of bile acids (BAs), lysophosphatidylcholines (LPCs), and polyunsaturated fatty acids (PUFAs) in biofluids may be very useful for diagnosis and prevention of hepatobiliary disease with a non-invasive manner. However, simultaneously fast analysis of these metabolites has been challenging for their huge differences of physicochemical properties and concentration levels in biofluids. In this study, we present a liquid chromatography-mass spectrometry method with a high throughput analytical cycle (10min) to fast and accurately quantify fifteen potential biomarkers (eight BAs, four LPCs and three PUFAs) of hepatobiliary disease. The accuracy for the fifteen analytes in plasma and urine matrices was 80.45%-118.99% and 84.55%-112.66%, respectively. The intra- and inter- precisions for the fifteen analytes in plasma and urine matrices were all less than 20% and the lower limit of quantification (LLOQ) of analytes is up to 0.0283-8.2172nmol/L. Therefore, this method is fast, sensitive and accurate for the quantitative analysis of BAs, LPCs and PUFAs in biofluids. Moreover, the stability and concentration differences of the analytes in plasma and serum were evaluated, and the results demonstrated that LPCs is stable, but PUFAs is very unstable in freeze and thaw cycles, and the concentrations of the analytes in serum were slightly higher than those in plasma. We suggested plasma may be a kind of better bio-sample than serum using for quantitative analysis of metabolites in blood, due to the characteristics of plasma are more close to blood than those of serum. Copyright © 2017 Elsevier B.V. All rights reserved.
Jiang, Han-Peng; Chu, Jie-Mei; Lan, Meng-Dan; Liu, Ping; Yang, Na; Zheng, Fang; Yuan, Bi-Feng; Feng, Yu-Qi
2016-09-02
More than 140 modified ribonucleosides have been identified in RNA. Determination of endogenous modified ribonucleosides in biological fluids may serve as non-invasive disease diagnostic strategy. However, detection of the modified ribonucleosides in biological fluids is challenging, especially for the low abundant modified ribonucleosides due to the serious matrix interferences of biological fluids. Here, we developed a facile preparation strategy and successfully synthesized zirconium oxide-silica (ZrO2/SiO2) composite capillary monolithic column that exhibited excellent performance for the selective enrichment of cis-diol-containing compounds. Compared with the boronate-based affinity monolith, the ZrO2/SiO2 monolith showed ∼2 orders of magnitude higher extraction capacity and can be used under physiological pH (pH 6.5-7.5). Using the prepared ZrO2/SiO2 composite monolith as the trapping column and reversed-phase C18 column as the analytical column, we further established an online solid-phase microextraction (SPME) in combination with liquid chromatography-mass spectrometry (online SPME-LC-MS/MS) analysis for the comprehensive profiling of ribonucleosides modification in human urine. Our results showed that 68 cis-diol-containing ribosylated compounds were identified in human urine, which is, to the best of our knowledge, the highest numbers of cis-diol-containing compounds were determined in a single analysis. It is worth noting that four modified ribonucleosides were discovered in the human urine for the first time. In addition, the quantification results from the pooled urine samples showed that compared to healthy controls, the contents of sixteen ribose conjugates in the urine of gastric cancer, eleven in esophagus cancer and seven in lymphoma increased more than two folds. Among these ribose conjugates, four ribose conjugates increased more than two folds in both gastric cancer and esophagus cancer; three ribose conjugates increased more than two folds in both gastric cancer and lymphoma; one ribose conjugate increased more than two folds in both esophagus cancer and lymphoma. The developed analytical method provides a good platform to study the modified ribonucleosides in human body fluids. Copyright © 2016 Elsevier B.V. All rights reserved.
A new method for quasi-reagent-free biomonitoring of mercury in human urine.
Schlathauer, Maria; Reitsam, Verena; Schierl, Rudolf; Leopold, Kerstin
2017-05-01
A novel analytical method for sampling and extraction of mercury (Hg) from human urine is presented in this work. The method is based on selective accumulation and separation of Hg from fresh urine sample onto active nanogold-coated silica material by highly efficient solid-phase extraction. After thermal desorption of Hg from the extractant, detection is performed by atomic fluorescence spectrometry (AFS). The feasibility and validity of the optimized, quasi-reagent-free approach was confirmed by recovery experiments in spiked real urine (recovery rate 96.13 ± 5.34%) and by comparison of found Hg concentrations in real urine samples - originating from occupationally exposed persons - with values obtained from reference methods cold vapor - atomic absorption spectrometry (CVAAS) and cold vapor - atomic fluorescence spectrometry (CV-AFS). A very good agreement of the found values reveals the validity of the proposed approach. The limit of detection (LOD) was found to be as low as 0.004 μg Hg L -1 and a high reproducibility with a relative standard deviations ≤4.2% (n = 6) is given. Moreover, storage of the samples for up to one week at an ambient temperature of 30 °C reveals no analyte losses or contamination. In conclusion, the proposed method enables easy-to-handle on-site extraction of total Hg from human urine ensuring at the same time reagent-free sample stabilization, providing quick and safe sampling, which can be performed by untrained persons. Copyright © 2017 Elsevier B.V. All rights reserved.
Cheng, Wing-Chi; Yau, Tsan-Sang; Wong, Ming-Kei; Chan, Lai-Ping; Mok, Vincent King-Kuen
2006-10-16
A rapid urinalysis system based on SPE-LC-MS/MS with an in-house post-analysis data management system has been developed for the simultaneous identification and semi-quantitation of opiates (morphine, codeine), methadone, amphetamines (amphetamine, methylamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxymethamphetamine (MDMA)), 11-benzodiazepines or their metabolites and ketamine. The urine samples are subjected to automated solid phase extraction prior to analysis by LC-MS (Finnigan Surveyor LC connected to a Finnigan LCQ Advantage) fitted with an Alltech Rocket Platinum EPS C-18 column. With a single point calibration at the cut-off concentration for each analyte, simultaneous identification and semi-quantitation for the above mentioned drugs can be achieved in a 10 min run per urine sample. A computer macro-program package was developed to automatically retrieve appropriate data from the analytical data files, compare results with preset values (such as cut-off concentrations, MS matching scores) of each drug being analyzed and generate user-defined Excel reports to indicate all positive and negative results in batch-wise manner for ease of checking. The final analytical results are automatically copied into an Access database for report generation purposes. Through the use of automation in sample preparation, simultaneous identification and semi-quantitation by LC-MS/MS and a tailored made post-analysis data management system, this new urinalysis system significantly improves the quality of results, reduces the post-data treatment time, error due to data transfer and is suitable for high-throughput laboratory in batch-wise operation.
ANALYTICAL METHOD FOR THE DETERMINATION OF PHENYLGLUCURONIDE IN RAINBOW TROUT GILL WATER
Phenylglucuronide (PG), a primary phase II metabolite of phenol, can be excreted by fish through urine and feces, similar to mammals. In addition, it may also be possible to eliminate it through a fish's gills. In order to assess the significance of gill water elimination, analyt...
Sánchez-González, Juan; Salgueiro-Fernández, Rocío; Cabarcos, Pamela; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2017-02-01
A molecularly imprinted polymer (MIP) selective for cannabinoids [Δ 9 -tetrahydrocannabinol (Δ9-THC), 11-nor-9-carboxy-Δ 9 -tetrahydrocannabinol (Δ9-THC-COOH), and 11-hydroxy-Δ 9 -tetrahydrocannabinol (Δ9-THC-OH)] has been synthesized, fully characterized, and applied to the assessment of plasma and urine analysis of marijuana abuse by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Δ9-THC-COOH was used as a template molecule, whereas ethylene glycol dimethacrylate (EGDMA) was used as a functional monomer, divinylbenzene (DVB) as a cross-linker, and 2,2'-azobisisobutyronitrile (AIBN) as an initiator. The prepared MIP was found to be highly selective for cannabinoids typically found in blood and urine, and also for cannabinol (CBN) and cannabidiol (CBD). MIP beads (50 mg) were loaded inside a cone-shaped device made of a polypropylene (PP) membrane for microsolid-phase extraction (μ-SPE) in batch mode. Optimum retention of analytes (0.1 to 1.0 mL of plasma/urine) was achieved by fixing plasma/urine pH at 6.5 and assisting the procedure by mechanical shaking (150 rpm, 40 °C, 12 min). Optimum elution conditions implied 2 mL of a 90:10 methanol/acetic acid and ultrasound extraction (35 kHz, 325 W) for 6 min. Good precision was assessed by intra-day and inter-day assays. In addition, the method was found to be accurate after intra-day and inter-day analytical recovery assays and after analyzing control serum and urine control samples. The limits of quantification were in the range of 0.36-0.49 ng L -1 (plasma analysis) and 0.47-0.57 ng L -1 (urine analysis). These values are low enough for confirmative conclusions regarding marijuana abuse through blood and urine analysis. Graphical Abstract ᅟ.
Approximate analytical modeling of leptospirosis infection
NASA Astrophysics Data System (ADS)
Ismail, Nur Atikah; Azmi, Amirah; Yusof, Fauzi Mohamed; Ismail, Ahmad Izani
2017-11-01
Leptospirosis is an infectious disease carried by rodents which can cause death in humans. The disease spreads directly through contact with feces, urine or through bites of infected rodents and indirectly via water contaminated with urine and droppings from them. Significant increase in the number of leptospirosis cases in Malaysia caused by the recent severe floods were recorded during heavy rainfall season. Therefore, to understand the dynamics of leptospirosis infection, a mathematical model based on fractional differential equations have been developed and analyzed. In this paper an approximate analytical method, the multi-step Laplace Adomian decomposition method, has been used to conduct numerical simulations so as to gain insight on the spread of leptospirosis infection.
Heinig, Katja; Herzog, Denis; Ferrari, Luca; Fraier, Daniela; Miya, Kazuhiro; Morcos, Peter N
2017-03-01
Alectinib (Alecensa ® ) is an anaplastic lymphoma kinase inhibitor for the treatment of anaplastic lymphoma kinase positive non-small-cell lung cancer, and M4 is its major pharmacologically active metabolite. To characterize the pharmacokinetics and excretion of alectinib and M4 in human urine, a bioanalytical method was required. An LC-MS/MS method using supported liquid extraction was developed for the determination of alectinib and M4 in human urine over the concentration range 0.5-500 ng/ml. Accuracy ranged from 92.0 to 112.2% and precision (CV) was below 9.6%. The method was successfully employed to determine alectinib and M4 concentrations in urine samples from a clinical mass balance study. Addition of the surfactant Tween-20 to urine prevented nonspecific binding of the analytes.
NASA Astrophysics Data System (ADS)
Jean, Ren-Der; Larsson, Mikael; Cheng, Wei-Da; Hsu, Yu-Yuan; Bow, Jong-Shing; Liu, Dean-Mo
2016-12-01
Metallic nanoparticles have been utilized as analytical tools to detect a wide range of organic analytes. In most reports, gold (Au)-based nanosensors have been modified with ligands to introduce selectivity towards a specific target molecule. However, in a recent study a new concept was presented where bare Au-nanorods on self-assembled carboxymethyl-hexanoyl chitosan (CHC) nanocarriers achieved sensitive and selective detection of human serum albumin (HSA) after manipulation of the solution pH. Here this concept was further advanced through optimization of the ratio between Au-nanorods and CHC nanocarriers to create a nanotechnology-based sensor (termed CHC-AuNR nanoprobe) with an outstanding lower detection limit (LDL) for HSA. The CHC-AuNR nanoprobe was evaluated in simulated urine solution and a LDL as low as 1.5 pM was achieved at an estimated AuNR/CHC ratio of 2. Elemental mapping and protein adsorption kinetics over three orders of magnitude in HSA concentration confirmed accumulation of HSA on the nanorods and revealed the adsorption to be completed within 15 min for all investigated concentrations. The results suggest that the CHC-AuNR nanoprobe has potential to be utilized for cost-effective detection of analytes in complex liquids.
[Automation and organization of technological process of urinalysis].
Kolenkin, S M; Kishkun, A A; Kol'chenko, O L
2000-12-01
Results of introduction into practice of a working model of industrial technology of laboratory studies and KONE Specific Supra and Miditron M devices are shown as exemplified by clinical analysis of the urine. This technology helps standardize all stages and operations, improves the efficiency of quality control of laboratory studies, rationally organizes the work at all stages of the process, creates a system for permanent improvement of the efficiency of investigations at the preanalytical, analytical, and postanalytical stages of technological process of laboratory studies. As a result of introduction of this technology into laboratory practice, violations of quality criteria of clinical urinalysis decreased from 15 to 8% at the preanalytical stage and from 6 to 3% at the analytical stage. Automation of the analysis decreased the need in reagents 3-fold and improved the productivity at the analytical stage 4-fold.
Analytical and Clinical Validation of the Immulite 1000 hCG Assay for Quantitative Analysis in Urine
Cate, Frances L.; Moffett, Courtney; Gronowski, Ann M.; Grenache, David G.; Hartmann, Katherine E.; Woodworth, Alison
2013-01-01
Background The Siemens Immulite hCG assay detects all major hCG variants in serum. Currently, this assay is only FDA approved for qualitative measurement of hCG in urine. Methods Complete validation of the hCG assay in urine was performed on the Siemens Immulite 1000 immunoassay platform. Reference intervals were established for females <55 y, females ≥55 y, and males 20–70 y. Results The limit of quantitation was 2.0 IU/l. The Immulite hCG assay was precise for measuring hCG in urine from pregnant patients with intra- and inter-assay imprecision of <11% CV. The assay was linear over a dynamic range of 2–2600 IU/l and 2–3500 IU/l for hCG and hCGβ respectively. The assay was non-linear for hCGβcf. No hook effect was observed at concentrations up to 1,200,000 pmol/l, for hCGβ or hCGβcf. The reference intervals were <2.0 IU/l for males, <2.2 IU/l for females <55 y, and <12.2 IU/l for females ≥55 y. Conclusion The Immulite 1000 hCG assay can accurately quantify hCG in urine. PMID:23470427
Laryea, Maurice D; Herebian, Diran; Meissner, Thomas; Mayatepek, Ertan
2010-12-01
Inborn errors of urea metabolism result in hyperammonemia. Treatment of urea cycle disorders can effectively lower plasma ammonium levels and results in survival in the majority of patients. Available medications for treating urea cycle disorders include sodium benzoate (BA), sodium phenylacetate (PAA), and sodium phenylbutyrate (PBA) and are given to provide alternate routes for disposition of waste nitrogen excretion. In this study, we develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of benzoic acid, phenylacetic acid, phenylbutyric acid, phenylacetylglutamine, and hippuric acid in plasma and urine from children with inborn errors of urea synthesis. Plasma extracts and diluted urine samples were injected on a reverse-phase column and identified and quantified by selected reaction monitoring (SRM) in negative ion mode. Deuterated analogues served as internal standards. Analysis time was 7 min. Assay precision, accuracy, and linearity and sample stability were determined using enriched samples. Quantification limits of the method were 100 ng/ml (0.3-0.8 μmol/L) for all analytes, and recoveries were >90%. Inter- and intraday relative standard deviations were <10%. Our newly developed LC-MS/MS represents a robust, sensitive, and rapid method that allows simultaneous determination of the five compounds in plasma and urine.
Guan, Fuyu; Robinson, Mary A
2017-09-08
The ability to analyze biological samples for multitudinous exogenous peptides with a single analytical method is desired for doping control in horse racing. The key to achieving this goal is the capability of extracting all target peptides from the sample matrix. In the present study, theory of mixed-mode solid-phase extraction (SPE) of peptides from plasma is described, and a generic mixed-mode SPE procedure has been developed for recovering multitudinous exogenous peptides with remarkable sequence diversity, from equine plasma and urine in a single procedure. Both the theory and the developed SPE procedure have led to the development of a novel analytical method for comprehensive detection of multitudinous bioactive peptides in equine plasma and urine using liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS). Thirty nine bioactive peptides were extracted with strong anion-exchange mixed-mode SPE sorbent, separated on a reversed-phase C 18 column and detected by HRMS and data-dependent tandem mass spectrometry. The limit of detection (LOD) was 10-50 pg mL -1 in plasma for most of the peptides and 100 pg mL -1 for the remaining. For urine, LOD was 20-400 pg mL -1 for most of the peptides and 1-4 ng mL -1 for the others. In vitro degradation of the peptides in equine plasma and urine was examined at ambient temperature; the peptides except those with a D-amino acid at position 2 were unstable not only in plasma but also in urine. The developed method was successful in analysis of plasma and urine samples from horses administered dermorphin. Additionally, dermorphin metabolites were identified in the absence of reference standards. The developed SPE procedure and LC-HRMS method can theoretically detect virtually all peptides present at a sufficient concentration in a sample. New peptides can be readily included in the method to be detected without method re-development. The developed method also generates such data that can be retrospectively analyzed for peptides unknown at the time of sample analysis. It is the first generic analytical method for comprehensive detection of multitudinous exogenous peptides in biological samples, to the authors' knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.
Kij, Agnieszka; Mateuszuk, Lukasz; Sitek, Barbara; Przyborowski, Kamil; Zakrzewska, Agnieszka; Wandzel, Krystyna; Walczak, Maria; Chlopicki, Stefan
2016-09-10
The balance between vascular prostacyclin (PGI2) generated mainly via cyclooxygenase-2 (COX-2) and its physiological antagonist platelet-derived thromboxane A2 (TXA2) formed by cyclooxygenase-1 (COX-1) determines cardiovascular homeostasis. In the present work, a novel bioanalytical method for simultaneous quantification of stable plasma and urinary metabolites of PGI2 (6-keto-PGF1α, 2,3-dinor-6-keto-PGF1α) and TXA2 (TXB2, 2,3-dinor-TXB2) using ultra high-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC/MS/MS) was developed. The method was validated using artificial plasma and urine and linearity range, intra- and inter-day precision and accuracy, recovery of analytes, relative and absolute matrix effect and stability of analytes were determined. The use of artificial biofluids improved the method sensitivity as it eliminated the contribution of endogenous metabolites present in mice plasma and urine to validation procedure. The newly developed and validated method allowed to quantify 6-keto-PGF1α and TXB2 in mice plasma as well as 2,3-dinor-6-keto-PGF1α and 2,3-dinor-TXB2 in urine samples with high sensitivity and accuracy. The calibration range was established from 0.1 to 100ng/mL for all analytes using artificial biofluids and the recoveries were greater than 89.9%. All validated parameters met the criteria of acceptance specified in FDA and EMA guidance. This method was successfully employed for profiling of the changes in PGI2 and TXA2 generation in NO-deficient mice. This work demonstrated that NO-deficiency induced by L-NAME, evidenced by a fall in nitrite in plasma and urine, was associated with platelet activation, robust increase in TXB2 and mild increase in 6-keto-PGF1α concentration in plasma. Changes in 2,3-dinor-6-keto-PGF1α and 2,3-dinor-TXB2 concentration in urine were less evident suggesting that the measurements in plasma better reflect modest changes in PGI2/TXA2 homeostasis than measurements in urine. Copyright © 2016 Elsevier B.V. All rights reserved.
Chung, Shuang-Hung; Ding, Wang-Hsien
2018-02-05
An analytical method that utilizes isotope-dilution gas chromatography-mass spectrometry (ID-GC-MS) coupled with injection-port butylation was developed. The method was validated, and confirmed to be able to determine the presence of three commonly detected endocrine-disrupting chemicals (EDCs: 4-tert-octylphenol (4-t-OP), 4-nonylphenols (4-NPs) and bisphenol A (BPA)) in human urine with high precision and accuracy. After sample preparation by solid-phase extraction, the extract was introduced into GC-MS via injection-port butylation. The butylated target analytes were identified and quantified by using ion-trap mass spectrometry operating in the selected-ion-storage mode, and employing the measurement of peak area ratios of the butylated target analytes and labeled-analogues in the samples and calibration standards. The labeled-analogues were also used to correct the variations associated with the analysis and matrix effect. The limits of quantitation (LOQs) ranged from 0.1 to 0.3ng/mL. High precisions for both intra- and inter-day analysis ranged from 1 to 6%, and excellent accuracy (mean recovery) ranged from 92 to 105% on two concentration levels. In human urine, the total concentrations of three selected EDCs varied from 1.28 to 7.14ng/mL. 4-NPs were detected within all collected samples. The developed method allows accurate analysis of trace-level of EDCs in urine, and these target EDCs could act as useful biomarkers to assess exposure in biomonitoring studies and programs. Copyright © 2017 Elsevier B.V. All rights reserved.
Abraham, Tsadik T.; Lowe, Ross H.; Pirnay, Stephane O.; Darwin, William D.; Huesti, Marilyn A.
2009-01-01
A sensitive and specific method for extraction and quantification of Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (11-OH-THC), and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) in human urine was developed and fully validated. To ensure complete hydrolysis of conjugates and capture of total analyte content, urine samples were hydrolyzed by two methods in series. Initial hydrolysis was with Escherichia coli β-glucuronidase (Type IX–A) followed by a second hydrolysis utilizing 10N NaOH. Specimens were adjusted to pH 5−6.5, treated with acetonitrile to precipitate protein, and centrifuged, and the supernatants were subjected to solid-phase extraction. Extracted analytes were derivatized with BSTFA and quantified by gas chromatography–mass spectrometry with electron impact ionization. Standard curves were linear from 2.5 to 300 ng/mL. Extraction efficiencies were 57.0−59.3% for THC, 68.3−75.5% for 11-OH-THC, and 71.5−79.7% for THCCOOH. Intra- and interassay precision across the linear range of the assay ranged from 0.1 to 4.3% and 2.6 to 7.4%, respectively. Accuracy was within 15% of target concentrations. This method was applied to the analysis of urine specimens collected from individuals participating in controlled administration cannabis studies, and it may be a useful analytical procedure for determining recency of cannabis use in forensic toxicology applications. PMID:17988462
Duenngai, Kunyarat; Wangboon, Chompunoot; Sithithaworn, Jiraporn; Watwiengkam, Nattaya; Namwat, Nisana; Techasen, Anchalee; Loilome, Watcharin; Yongvanit, Puangrat; Loukas, Alex; Sithithaworn, Paiboon; Bethony, Jeffrey M.
2015-01-01
Background Many strategies to control opisthorchiasis have been employed in Thailand, but not in the other neighbouring countries. Specific control methods include mass drug administration (MDA) and health education to reduce raw fish consumption. These control efforts have greatly shifted the epidemiology of Opisthorchis viverrini (OV) infection over the last decade from presenting as densely concentrated "heavy" infections in single villages to widespread "light" OV infections distributed over wide geographical areas. Currently, the "gold standard" detection method for OV infection is formalin ethyl-acetate concentration technique (FECT), which has limited diagnostic sensitivity and diagnostic specificity for light OV infections, with OV eggs often confused with eggs of minute intestinal flukes (MIFs) in feces. In this study, we developed and evaluated the diagnostic performance of a monoclonal antibody-based enzyme-linked immunosorbent assay for the measurement of OV excretory-secretory (ES) antigens in urine (urine OV-ES assay) for the diagnosis of opisthorchiasis compared to the gold standard detection FECT method. Methodology We tested several methods for pre-treating urine samples prior to testing the diagnostic performance of the urine OV-ES assay. Using trichloroacetic acid (TCA) pre-treated urine, we compared detection and quantification of OV infection using the urine OV-ES assay versus FECT in OV-endemic areas in Northeastern Thailand. Receiver operating characteristic (ROC) curves were used to determine the diagnostic sensitivity and specificity of the urine OV-ES assay using TCA pre-treated urine, and to establish diagnostic positivity thresholds. The Positive Predictive Value as well as the likelihood of obtaining a positive test result (LR+) or a negative test result (LR-) were calculated for the established diagnostic positivity threshold. Diagnostic risks (Odds Ratios) were estimated using logistic regression. Results When urine samples were pre-treated with TCA prior to use in the urine OV-ES assay, the analytical sensitivity was significantly improved. Using TCA pre-treatment of urine, the urine OV-ES assay had a limit of detection (LoD) of 39 ng/ml compared to the LoD of 52 ng/mL reported for coprological antigen detection methods. Similarly, the urine OV-ES assay correlated significantly with intensity of OV infection as measured by FECT. The urine OV-ES assay was also able to detect 28 individuals as positive from the 63 (44.4%) individuals previously determined to be negative using FECT. The likelihood of a positive diagnosis of OV infection by urine OV-ES assay increased significantly with the intensity of OV infection as determined by FECT. With reference to FECT, the sensitivity and specificity of the urine OV-ES assay was 81% and 70%, respectively. Conclusion The detection of OV-infection by the urine OV-ES assay showed much greater diagnostic sensitivity and diagnostic specificity than the current "gold standard" FECT method for the detection and quantification of OV infection. Due to its ease-of-use, and noninvasive sample collection (urine), the urine OV-ES assay offers the potential to revolutionize the diagnosis of liver fluke infection and provide an effective tool for control and elimination of these tumorigenic parasites. PMID:26485024
Mardal, Marie; Kinyua, Juliet; Ramin, Pedram; Miserez, Bram; Van Nuijs, Alexander L N; Covaci, Adrian; Meyer, Markus R
2017-01-01
Monitoring population drug use through wastewater-based epidemiology (WBE) is a useful method to quantitatively follow trends and estimate total drug consumption in communities. Concentrations of drug biomarkers might be low in wastewater due to dilution; and therefore analysis of pooled urine (PU) is useful to detect consumed drugs and identify targets of illicit drugs use. The aims of the study were (1) to screen PU and urinated soil (US) samples collected at festivals for illicit drug excretion products using hyphenated techniques; (2) to develop and validate a hydrophilic interaction liquid chromatography - mass spectrometry / mass spectrometry (HILIC-MS/MS) method of quantifying urinary targets of identified drugs in wastewater; and (3) to conduct a 24 h stability study, using PU and US to better reflect the chemical environment for targets in wastewater. Cocaine (COC) and ecstasy-like compounds were the most frequently detected illicit drugs; an analytical method was developed to quantify their excretion products. Hydroxymethoxymethamphetamine (HMMA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), HMMA sulfate (HMMA-S), benzoylecgonine (BE), and cocaethylene (CE) had 85-102% of initial concentration after 8 h of incubation, whereas COC and ecgonine methyl ester (EME) had 74 and 67% after 8 h, respectively. HMMA showed a net increase during 24 h of incubation (107% ± 27, n = 8), possibly due to the cleavage of HMMA conjugates, and biotransformation of MDMA. The results suggest HMMA as analytical target for MDMA consumption in WBE, due to its stability in wastewater and its excretion as the main phase I metabolite of MDMA. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Clinical evaluation of Roche COBAS® AmpliPrep/COBAS® TaqMan® CMV Test using non-plasma samples.
Hildenbrand, Cynthia; Wedekind, Laura; Li, Ge; vonRentzell, Jeanne E; Shah, Krunal; Rooney, Paul; Harrington, Amanda T; Zhao, Richard Y
2018-05-24
Cytomegalovirus (CMV) infection is a leading cause of loss of hearing, vision, and mental retardation in congenitally infected children. It is also associated with complications of organ-transplant and opportunistic HIV co-infection. The Roche COBAS ® AmpliPrep/COBAS ® TaqMan ® CMV Test is a FDA-approved test that measures CMV DNA viral load in plasma for the diagnosis and management of patients at risk for CMV-associated diseases. Besides plasma, CMV is often found in bronchoalveolar lavage (BAL), cerebrospinal fluid (CSF) and urine. Thus, monitoring of CMV for critical care of patients in these non-plasma samples becomes necessary. The objective of this study was to conduct an analytic and clinical feasibility study of the Roche CMV Test in BAL, CSF, and urine. The lower limit of detection (LOD), analytic measurement range (AMR), assay sensitivity, specificity, and precision were determined. Results of this study showed the LODs were 50, 100 and 300 IU/mL for BAL, CSF, or urine, respectively. The AMRs were from log 10 2.48 to log 10 5.48. The assay specificity was 94.4% for BAL, and 100% for CSF and urine. The assay precision was all within the acceptable range. The performance of Roche test was further compared with two comparators including the RealTime CMV Assay (Abbott Molecular) and a CMV Quantitative PCR Test (Vela Diagnostics). There was a general positive correlation between the Roche method and the Abbott or the Vela method. Overall, this study suggests the Roche CMV Test is suitable for the quantification of CMV viral load DNA in the described non-plasma samples. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Stanley, Shawn M R; Wee, Wei Khee; Lim, Boon Huat; Foo, Hsiao Ching
2007-04-01
Direct-injection LC-LC hybrid tandem MS methods have been developed for undertaking broad-based screening for acidic drugs in protein-precipitated plasma and neutral doping agents in equine urine. In both analyses, analytes present in the matrix were trapped using a HLB extraction column before being refocused and separated on a Chromolith RP-18e monolithic analytical column using a controlled differential gradient generated by proportional dilution of the first column's eluent with water. Each method has been optimised by the adoption of a mobile phase and gradient that was tailored to enhance ionisation in the MS source while maintaining good chromatographic behaviour for the majority of the target drugs. The analytical column eluent was fed into the heated nebulizer (HN) part of the Duospray interface attached to a 4000 QTRAP mass spectrometer. Information dependent acquisition (IDA) with dynamic background subtraction (DBS) was configured to trigger a sensitive enhanced product ion (EPI) scan when a multiple reaction monitoring (MRM) survey scan signal exceeded the defined criteria. Ninety-one percent of acidic drugs in protein-precipitated plasma and 80% of the neutral compounds in equine urine were detected when spiked at 10 ng/ml.
RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, S.; Culligan, B.
2008-08-27
The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared tomore » NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.« less
Salinas, Maria; Lopez-Garrigos, Maite; Flores, Emilio; Leiva-Salinas, Carlos
2018-06-01
To study the urinalysis request, pre-analytical sample conditions, and analytical procedures. Laboratories were asked to provide the number of primary care urinalyses requested, and to fill out a questionnaire regarding pre-analytical conditions and analytical procedures. 110 laboratories participated in the study. 232.5 urinalyses/1,000 inhabitants were reported. 75.4% used the first morning urine. The sample reached the laboratory in less than 2 hours in 18.8%, between 2 - 4 hours in 78.3%, and between 4 - 6 hours in the remaining 2.9%. 92.5% combined the use of test strip and particle analysis, and only 7.5% used the strip exclusively. All participants except one performed automated particle analysis depending on strip results; in 16.2% the procedure was only manual. Urinalysis was highly requested. There was a lack of compliance with guidelines regarding time between micturition and analysis that usually involved the combination of strip followed by particle analysis.
Alladio, Eugenio; Caruso, Roberto; Gerace, Enrico; Amante, Eleonora; Salomone, Alberto; Vincenti, Marco
2016-05-30
The Technical Document TD2014EAAS was drafted by the World Anti-Doping Agency (WADA) in order to fight the spread of endogenous anabolic androgenic steroids (EAAS) misuse in several sport disciplines. In particular, adoption of the so-called Athlete Biological Passport (ABP) - Steroidal Module allowed control laboratories to identify anomalous EAAS concentrations within the athletes' physiological urinary steroidal profile. Gas chromatography (GC) combined with mass spectrometry (MS), indicated by WADA as an appropriate technique to detect urinary EAAS, was utilized in the present study to develop and fully-validate an analytical method for the determination of all EAAS markers specified in TD2014EAAS, plus two further markers hypothetically useful to reveal microbial degradation of the sample. In particular, testosterone, epitestosterone, androsterone, etiocholanolone, 5α-androstane-3α,17β-diol, 5β-androstane-3α,17β-diol, dehydroepiandrosterone, 5α-dihydrotestosterone, were included in the analytical method. Afterwards, the multi-parametric feature of ABP profile was exploited to develop a robust approach for the detection of EAAS misuse, based on multivariate statistical analysis. In particular, Principal Component Analysis (PCA) was combined with Hotelling T(2) tests to explore the EAAS data obtained from 60 sequential urine samples collected from six volunteers, in comparison with a reference population of single urine samples collected from 96 volunteers. The new approach proved capable of identifying anomalous results, including (i) the recognition of samples extraneous to each of the individual urine series and (ii) the discrimination of the urine samples collected from individuals to whom "endogenous" steroids had been administrated with respect to the rest of the samples population. The proof-of-concept results presented in this study will need further extension and validation on a population of sport professionals. Copyright © 2016 Elsevier B.V. All rights reserved.
Uralets, Victor; App, Mike; Rana, Sumandeep; Morgan, Stewart; Ross, Wayne
2014-03-01
2-Ethylamino-1-phenylbutane (EAPB) and 2-amino-1-phenylbutane (APB) were identified by gas chromatography-mass spectrometry in multiple urine samples submitted for stimulant drug testing and screened positive for amphetamines by enzyme immunoassay. Forty-two samples from all over the USA were found, containing both analytes during a 3-month period May-July 2013. A sports dietary supplement 'CRAZE' has been determined to be one of the sources of EAPB supply. EAPB along with its suggested metabolite APB were detected in a urine sample, obtained from a person known to use 'CRAZE'.
de Oliveira, Ricardo A G; Camargo, Fiamma; Pesquero, Naira C; Faria, Ronaldo Censi
2017-03-08
This paper describes the fabrication of 2D and 3D microfluidic paper-based analytical devices (μPADs) for monitoring glucose, total protein, and nitrite in blood serum and artificial urine. A new method of cutting and sealing filter paper to construct μPADs was demonstrated. Using an inexpensive home cutter printer soft cellulose-based filter paper was easily and precisely cut to produce pattern hydrophilic microchannels. 2D and 3D μPADs were designed with three detection zones each for the colorimetric detection of the analytes. A small volume of samples was added to the μPADs, which was photographed after 15 min using a digital camera. Both μPADs presented an excellent analytical performance for all analytes. The 2D device was applied in artificial urine samples and reached limits of detection (LODs) of 0.54 mM, 5.19 μM, and 2.34 μM for glucose, protein, and nitrite, respectively. The corresponding LODs of the 3D device applied for detecting the same analytes in artificial blood serum were 0.44 mM, 1.26 μM, and 4.35 μM. Copyright © 2017 Elsevier B.V. All rights reserved.
Asfaram, Arash; Ghaedi, Mehrorang; Purkait, Mihir Kumar
2017-09-01
A sensitive analytical method is investigated to concentrate and determine trace level of Sildenafil Citrate (SLC) present in water and urine samples. The method is based on a sample treatment using dispersive solid-phase micro-extraction (DSPME) with laboratory-made Mn@ CuS/ZnS nanocomposite loaded on activated carbon (Mn@ CuS/ZnS-NCs-AC) as a sorbent for the target analyte. The efficiency was enhanced by ultrasound-assisted (UA) with dispersive nanocomposite solid-phase micro-extraction (UA-DNSPME). Four significant variables affecting SLC recovery like; pH, eluent volume, sonication time and adsorbent mass were selected by the Plackett-Burman design (PBD) experiments. These selected factors were optimized by the central composite design (CCD) to maximize extraction of SLC. The results exhibited that the optimum conditions for maximizing extraction of SLC were 6.0 pH, 300μL eluent (acetonitrile) volume, 10mg of adsorbent and 6min sonication time. Under optimized conditions, virtuous linearity of SLC was ranged from 30 to 4000ngmL -1 with R 2 of 0.99. The limit of detection (LOD) was 2.50ngmL -1 and the recoveries at two spiked levels were ranged from 97.37 to 103.21% with the relative standard deviation (RSD) less than 4.50% (n=15). The enhancement factor (EF) was 81.91. The results show that the combination UAE with DNSPME is a suitable method for the determination of SLC in water and urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Carlson, M; Thompson, R D
2001-01-01
A liquid chromatographic (LC) method was developed for the determination of allantoin, uric acid, and indoxyl sulfate in mammalian urine contaminated packaging material including paper bagging, corrugated cardboard, grayboard, and burlap bagging. The procedure involves solvent extraction and isolation of the 3 analytes by reversed-phase LC with ultraviolet detection at 225 nm for allantoin and 286 nm for uric acid and indoxyl sulfate. The composition of authentic mammalian urine such as mouse, rat, cat, dog, and human were also determined with regard to the 3 compounds of interest. A linear concentration range of 0.11-20.4, 0.02-10.0, and 0.04-30.0 microg/mL was obtained for allantoin, uric acid, and indoxyl sulfate, respectively. Limits of detection (LOD) and quantitation (LOQ) were 0.0104 and 0.0345 microg/mL for allantoin; 0.0018 and 0.0060 microg/mL for uric acid; and 0.0049 and 0.0165 microg/mL for indoxyl sulfate, respectively. Interday relative standard deviation values for a mixture of standard allantoin, uric acid, and indoxyl sulfate (n = 5) were 0.97, 0.80, and 0.94%, respectively. Analyte composition for 5 types of authentic mammalian urine varied from 0.19-6.88 mg/mL allantoin; 0.08-0.57 mg/mL uric acid; and 0.03-0.78 mg/mL indoxyl sulfate. Analyte content for 8 samples including 2 samples each for paper, cardboard, grayboard, and burlap bagging each contaminated with mouse or rat urine ranged from
Impact of pH on Urine Chemistry Assayed on Roche Analyzers.
Cohen, R; Alkouri, R; Tostivint, I; Djiavoudine, S; Mestari, F; Dever, S; Atlan, G; Devilliers, C; Imbert-Bismut, F; Bonnefont-Rousselot, D; Monneret, D
2017-10-01
The pH may impact the concentration of certain urinary parameters, making urine pre-treatment questionable. 1) Determining the impact of pH in vitro on the urinary concentration of chemistry parameters assayed on Roche Modular analyzers. 2) Evaluating whether concentrations depended on pH in non-pretreated urines from patients. 1) The optimal urinary pH values for each measurement were: 6.3 ± 0.8 (amylase), < 5.5 (calcium and magnesium), < 6.5 (phosphorus), > 6.5 (uric acid). Urinary creatinine, sodium and urea concentrations were not pH-dependent. 2) In urines from patients, the pH was negatively associated with the concentration of some urinary parameters. However, concentrations of all the parameters were strongly and positively correlated with urinary creatinine, and relationships with pH were no longer evidenced after creatinine-normalization. The need for urine pH adjustment does not seem necessary when considering renal function. However, from an analytical and accreditation standpoint, the relationship between urine pH and several parameters justifies its measurement.
Kraemer, Thomas; Roditis, Susanne K; Peters, Frank T; Maurer, Hans H
2003-03-01
Prenylamine (R,S-N-(3,3-diphenylpropyl-methyl-2-phenethylamine), a World Health Organization class V calcium antagonist, is known to be metabolized to amphetamine. In this study, amphetamine concentrations after a single-dose administration of prenylamine were determined to check if they reached values that could be of analytical and/or pharmacological importance in clinical and forensic toxicology. Enantiomeric composition of amphetamine was also studied. Five volunteers received a single 120-mg oral dose of prenylamine. Urine samples were analyzed using the Abbott TDx immunoassay Amphetamine/Methamphetamine II and using our routine systematic toxicological analysis (STA) gas chromatography-mass spectrometry (GC-MS) procedure. For quantitation purposes, GC-MS was used in the selected-ion monitoring (SIM) mode (ions m/z 118, 122, 240, 244) after solid-phase extraction (Isolute Confirm HCX) and derivatization (heptafluorobutyric anhydride). Amphetamine-d5 was used as internal standard (IS). Chiral separation of the heptafluorobutyrated amphetamine enantiomers was achieved using an Astec Chiraldex G-PN column. The TDx results showed a great variability for the different volunteers. A urine sample of one volunteer showed results as high as 3200 ng/mL, whereas the urine samples of another volunteer never gave results greater than the TDx detection limit (100 ng/mL). Using the STA procedure, the presence of amphetamine could be confirmed in all urine samples with TDx results greater than the cutoff value (300 ng/mL). Using the GC-MS SIM method, amphetamine concentrations up to 1280 ng/mL were determined. Chiral analysis revealed that both enantiomers of amphetamine were present in the samples with a surplus of the S(+)-enantiomer in the early phase of excretion. Forensic implications are discussed.
Prapamontol, Tippawan; Sutan, Kunrunya; Laoyang, Sompong; Hongsibsong, Surat; Lee, Grace; Yano, Yukiko; Hunter, Ronald Elton; Ryan, P Barry; Barr, Dana Boyd; Panuwet, Parinya
2014-01-01
We report two analytical methods for the measurement of dialkylphosphate (DAP) metabolites of organophosphate pesticides in human urine. These methods were independently developed/modified and implemented in two separate laboratories and cross validated. The aim was to develop simple, cost effective, and reliable methods that could use available resources and sample matrices in Thailand and the United States. While several methods already exist, we found that direct application of these methods required modification of sample preparation and chromatographic conditions to render accurate, reliable data. The problems encountered with existing methods were attributable to urinary matrix interferences, and differences in the pH of urine samples and reagents used during the extraction and derivatization processes. Thus, we provide information on key parameters that require attention during method modification and execution that affect the ruggedness of the methods. The methods presented here employ gas chromatography (GC) coupled with either flame photometric detection (FPD) or electron impact ionization-mass spectrometry (EI-MS) with isotopic dilution quantification. The limits of detection were reported from 0.10ng/mL urine to 2.5ng/mL urine (for GC-FPD), while the limits of quantification were reported from 0.25ng/mL urine to 2.5ng/mL urine (for GC-MS), for all six common DAP metabolites (i.e., dimethylphosphate, dimethylthiophosphate, dimethyldithiophosphate, diethylphosphate, diethylthiophosphate, and diethyldithiophosphate). Each method showed a relative recovery range of 94-119% (for GC-FPD) and 92-103% (for GC-MS), and relative standard deviations (RSD) of less than 20%. Cross-validation was performed on the same set of urine samples (n=46) collected from pregnant women residing in the agricultural areas of northern Thailand. The results from split sample analysis from both laboratories agreed well for each metabolite, suggesting that each method can produce comparable data. In addition, results from analyses of specimens from the German External Quality Assessment Scheme (G-EQUAS) suggested that the GC-FPD method produced accurate results that can be reasonably compared to other studies. Copyright © 2013 Elsevier GmbH. All rights reserved.
Adsorption losses from urine-based cannabinoid calibrators during routine use.
Blanc, J A; Manneh, V A; Ernst, R; Berger, D E; de Keczer, S A; Chase, C; Centofanti, J M; DeLizza, A J
1993-08-01
The major metabolite of cannabis found in urine, 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid (delta 9-THC), is the compound most often used to calibrate cannabinoid immunoassays. The hydrophobic delta 9-THC molecule is known to adsorb to solid surfaces. This loss of analyte from calibrator solutions can lead to inaccuracy in the analytical system. Because the calibrators remain stable when not used, analyte loss is most probably caused by handling techniques. In an effort to develop an effective means of overcoming adsorption losses, we quantified cannabinoid loss from calibrators during the testing process. In studying handling of these solutions, we found noticeable, significant losses attributable to both the kind of pipette used for transfer and the contact surface-to-volume ratio of calibrator solution in the analyzer cup. Losses were quantified by immunoassay and by radioactive tracer. We suggest handling techniques that can minimize adsorption of delta 9-THC to surfaces. Using the appropriate pipette and maintaining a minimum surface-to-volume ratio in the analyzer cup effectively reduces analyte loss.
Aerosol dilution as a simple strategy for analysis of complex samples by ICP-MS.
Barros, Ariane I; Pinheiro, Fernanda C; Amaral, Clarice D B; Lorençatto, Rodolfo; Nóbrega, Joaquim A
2018-02-01
This study investigated the capability of High Matrix Introduction (HMI) strategy for analysis of dialysis solution and urine samples using inductively coupled plasma mass spectrometry. The use of HMI enables the direct introduction of urine samples and dialysis solutions 2-fold diluted with 0.14molL -1 HNO 3 . Bismuth, Ge, Ir, Li, Pt, Rh, Sc and Tl were evaluated as internal standards for Al, Ag, As, Be, Cd, Cr, Pb, Sb, Se, Tl, and Hg determination in dialysis solution and As, Cd, Hg and Pb determination in urine samples. Helium collision cell mode (4.5mLmin -1 ) was efficient to overcome polyatomic interferences in As, Se and Cr determinations. Mercury memory effects were evaluated by washing with 0.12molL -1 HCl or an alkaline diluent solution prepared with n-butanol, NH 4 OH, EDTA, and Triton X-100. This later solution was efficient for avoiding Hg memory effects in 6h of analysis. Linear calibration curves were obtained for all analytes and detection limits were lower than maximum amounts allowed by Brazilian legislations. Recoveries for all analytes in dialysis solutions and urine samples ranged from 82% to 125% and relative standard deviations for all elements and samples were lower than 7%. Analysis of control internal urine samples was in agreement with certified values at 95% confidence level (t-test; p < 0.05). Copyright © 2017 Elsevier B.V. All rights reserved.
Alshogran, Osama Y; Ocque, Andrew J; Leblond, François A; Pichette, Vincent; Nolin, Thomas D
2016-04-01
A simple and rapid liquid chromatographic-tandem mass spectrometric method has been developed and validated for the enantiospecific determination of R- and S-warfarin in human urine. Warfarin enantiomers were extracted from urine using methyl tert-butyl ether. Chromatographic separation of warfarin enantiomers and the internal standard d5-warfarin was achieved using a Astec Chirobiotic V column with gradient mobile phase at a flow rate of 400 µL/min over 10 min. Detection was performed on a TSQ Quantum Ultra triple quadrupole mass spectrometer equipped with a heated electrospray ionization source. Analytes were detected in negative ionization mode using selected reaction monitoring. Calibration curves were linear with a correlation coefficient of ≥0.996 for both enantiomers over a concentration range of 5-500 ng/mL. The intra- and interday accuracy and precision for both analytes were within ±9.0%. Excellent extraction efficiency and negligible matrix effects were observed. The applicability of the method was demonstrated by successful measurement of warfarin enantiomers in urine of patients with kidney disease. The method is simple, accurate and reproducible and is currently being used to support warfarin pharmacokinetic studies. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Judák, Péter; Grainger, Janelle; Goebel, Catrin; Van Eenoo, Peter; Deventer, Koen
2017-08-01
The mobile phase additive (DMSO) has been described as a useful tool to enhance electrospray ionization (ESI) of peptides and proteins. So far, this technique has mainly been used in proteomic/peptide research, and its applicability in a routine clinical laboratory setting (i.e., doping control analysis) has not been described yet. This work provides a simple, easy to implement screening method for the detection of doping relevant small peptides (GHRPs, GnRHs, GHS, and vasopressin-analogues) with molecular weight less than 2 kDa applying DMSO in the mobile phase. The gain in sensitivity was sufficient to inject the urine samples after a 2-fold dilution step omitting a time consuming sample preparation. The employed analytical procedure was validated for the qualitative determination of 36 compounds, including 13 metabolites. The detection limits (LODs) ranged between 50 and 1000 pg/mL and were compliant with the 2 ng/mL minimum detection level required by the World Anti-Doping Agency (WADA) for all the target peptides. To demonstrate the feasibility of the work, urine samples obtained from patients who have been treated with desmopressin or leuprolide and urine samples that have been declared as adverse analytical findings were analyzed.
Validation of an ELISA Synthetic Cannabinoids Urine Assay.
Barnes, Allan J; Spinelli, Eliani; Young, Sheena; Martin, Thomas M; Kleete, Kevin L; Huestis, Marilyn A
2015-10-01
Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug-testing laboratories. We evaluated performance of the National Medical Services (NMS) JWH-018 direct enzyme-linked immunosorbent assay (ELISA) kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was used to screen 2492 urine samples with 5 and 10 mcg/L cutoffs. A fully validated liquid chromatography-tandem mass spectrometry method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25% and ±50% of cutoffs determined intraplate and interplate imprecision around proposed cutoffs. The immunoassay was linear from 1 to 500 mcg/L with intraplate and interplate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, coadministered drugs, over-the-counter medications, or structurally similar compounds, and 19 of 73 individual synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4%, and 97.6%, as well as 71.6%, 99.7%, and 96.4% with the 5 and 10 mcg/L urine cutoffs, respectively. This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5 mcg/L urine cutoff.
Cao, Xiaoqin; Li, Xiaofei; Li, Jian; Niu, Yunhui; Shi, Lu; Fang, Zhenfeng; Zhang, Tao; Ding, Hong
2018-01-15
A sensitive and reliable multi-mycotoxin-based method was developed to identify and quantify several carcinogenic mycotoxins in human blood and urine, as well as edible animal tissues, including muscle and liver tissue from swine and chickens, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). For the toxicokinetic studies with individual mycotoxins, highly sensitive analyte-specific LC-MS/MS methods were developed for rat plasma and urine. Sample purification consisted of a rapid 'dilute and shoot' approach in urine samples, a simple 'dilute, evaporate and shoot' approach in plasma samples and a 'QuEChERS' procedure in edible animal tissues. The multi-mycotoxin and analyte-specific methods were validated in-house: The limits of detection (LOD) for the multi-mycotoxin and analyte-specific methods ranged from 0.02 to 0.41 μg/kg (μg/L) and 0.01 to 0.19 μg/L, respectively, and limits of quantification (LOQ) between 0.10 to 1.02 μg/kg (μg/L) and 0.09 to 0.47 μg/L, respectively. Apparent recoveries of the samples spiked with 0.25 to 4 μg/kg (μg/L) ranged from 60.1% to 109.8% with relative standard deviations below 15%. The methods were successfully applied to real samples. To the best of our knowledge, this is the first study carried out using a small group of patients from the Chinese population with hepatocellular carcinoma to assess their exposure to carcinogenic mycotoxins using biomarkers. Finally, the multi-mycotoxin method is a useful analytical method for assessing exposure to mycotoxins edible in animal tissues. The analyte-specific methods could be useful during toxicokinetic and toxicological studies. Copyright © 2017. Published by Elsevier B.V.
Thomas, Andreas; Walpurgis, Katja; Krug, Oliver; Schänzer, Wilhelm; Thevis, Mario
2012-10-12
In the present study, a screening assay was developed comprising 11 prohibited peptides (<1.5 kDa) that are sufficiently purified from urine using weak cation exchange with subsequent determination of all substances by means of nanoUHPLC separation coupled to high resolution tandem mass spectrometry. These peptides included Gonadorelin (LH-RH), Desmopressin and 9 growth hormone releasing peptides (GHRP-1, -2, -4, -5, -6, Hexarelin, Alexamorelin, Ipamorelin and a GHRP-2 metabolite); however, the procedure is expandable to further target analytes or metabolites. The method was validated with a main focus on qualitative result interpretation considering the parameters specificity, linearity (0-500 pg/mL), recovery (45-95%), precision (<20% at 100 pg/mL), limits of detection (2-10 pg/mL), robustnesss and ion suppression. The proof-of-principle was shown by analysing excretion study urine samples for LHRH, Desmopressin and GHRP-2. Copyright © 2012 Elsevier B.V. All rights reserved.
Gomo, Z A; Henderson, L O; Myrick, J E
1988-09-01
A high-resolution two-dimensional electrophoretic method for protein, with silver staining, has been used to characterize and identify urinary high-density-lipoprotein apolipoproteins (HDL-Apos) and their isoforms in healthy subjects and in patients with kidney disease. Analytical techniques based on both molecular mass and ultracentrifugal flotation properties were used to isolate urinary lipoprotein particles with characteristics identical to those of HDL in plasma. HDL-Apos identified in urine of normal subjects and patients with glomerular proteinuria were Apos A-I, A-II, and C. Five isoforms of Apo A-I were present. Immunostaining of electroblotted proteins further confirmed the presence of HDL-Apos in urine. Creatinine clearance rate was decreased in the patients with proteinuria, and ranged from 32.5 to 40 mL/min. Concentrations of cholesterol and triglycerides in serum were greater in the patients' group, whereas mean HDL-cholesterol (0.68, SD 0.10 mmol/L) and Apo A-I (0.953, SD 0.095 g/L) were significantly (each P less than 0.01) lower. Results of this study suggest that measurement of urinary Apo A-I will reflect excretion of HDL in urine.
Kim, James A; Ptolemy, Adam S; Melanson, Stacy E F; Janfaza, David R; Ross, Edgar L
2015-06-01
The urine of a patient admitted for chest and epigastric pain tested positive for cocaine using an immunoassay-based drug screening method (positive/negative cutoff concentration 150 ng/mL). Despite the patient's denial of recent cocaine use, this positive cocaine screening result in conjunction with a remote history of drug misuse impacted the patient's recommended pain therapy. Specifically, these factors prompted the clinical team to question the appropriateness of opioids and other potentially addictive therapeutics during the treatment of cancer pain from previously undetected advanced pancreatic carcinoma. After pain management and clinical pathology consultation, it was decided that the positive cocaine screening result should be confirmed by gas chromatography-mass spectrometry (GC-MS) testing. This more sensitive and specific analytical technique revealed that both cocaine and its primary metabolite benzoylecgonine were undetectable (i.e., less than the assay detection limit of 50 ng/mL), thus indicating that the positive urine screening result was falsely positive. With this confirmation, the pain management service team was reassured in offering intrathecal pump (ITP) therapy for pain control. ITP implantation was well tolerated, and the patient eventually achieved excellent pain relief. However, ITP therapy most likely would not have been utilized without the GC-MS confirmation testing unless alternative options failed and extensive vigilant monitoring was initiated. As exemplified in this case, confirmatory drug testing should be performed on specimens with unexpected immunoassay-based drug screening results. To our knowledge, this is the first report of a false-positive urine cocaine screening result and its impact on patient management. Wiley Periodicals, Inc.
Jeong, Yu-Dong; Kim, Min Kyung; Suh, Sung Ill; In, Moon Kyo; Kim, Jin Young; Paeng, Ki-Jung
2015-12-01
Benzodiazepines and zolpidem are generally prescribed as sedative, hypnotics, anxiolytics or anticonvulsants. These drugs, however, are frequently misused in drug-facilitated crime. Therefore, a rapid and simple liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for identification and quantification of benzodiazepines, zolpidem and their metabolites in urine using deuterium labeled internal standards (IS). Urine samples (120 μL) mixed with 80 μL of the IS solution were centrifuged. An aliquot (5 μL) of the sample solution was directly injected into the LC-MS/MS system for analysis. The mobile phases consisted of water and acetonitrile containing 2mM ammonium trifluoroacetate and 0.2% acetic acid. The analytical column was a Zorbax SB-C18 (100 mm × 2.1 mm i.d., 3.5 μm, Agilent). The separation and detection of 18 analytes were achieved within 10 min. Calibration curves were linear over the concentration ranges of 0.5-20 ng/mL (zolpidem), 1.0-40 ng/mL (flurazepam and temazepam), 2.5-100 ng/mL (7-aminoclonazepam, 1-hydroxymidazolam, midazolam, flunitrazepam and alprazolam), 5.0-200 ng/mL (zolpidem phenyl-4-carboxylic acid, α-hydroxyalprazolam, oxazepam, nordiazepam, triazolam, diazepam and α-hydroxytriazolam), 10-400 ng/mL (lorazepam and desalkylflurazepam) and 10-100 ng/mL (N-desmethylflunitrazepam) with the coefficients of determination (r(2)) above 0.9971. The dilution integrity of the analytes was examined for supplementation of short linear range. Dilution precision and accuracy were tested using two, four and ten-folds dilutions and they ranged from 3.7 to 14.4% and -12.8 to 12.5%, respectively. The process efficiency for this method was 63.0-104.6%. Intra- and inter-day precisions were less than 11.8% and 9.1%, while intra- and inter-day accuracies were less than -10.0 to 8.2%, respectively. The lower limits of quantification were lower than 10 ng/mL for each analyte. The applicability of the developed method was successfully verified with human urine samples from drug users (n=21). Direct urine sample injection and optimized mobile phases were introduced for simple sample preparation and high-sensitivity with the desired separation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Lower Cutoffs for LC-MS/MS Urine Drug Testing Indicates Better Patient Compliance.
Krock, Kevin; Pesce, Amadeo; Ritz, Dennis; Thomas, Richard; Cua, Agnes; Rogers, Ryan; Lipnick, Phil; Kilbourn, Kristen
2017-11-01
Urine drug testing is used by health care providers to determine a patient's compliance to their prescribed regimen and to detect non-prescribed medications and illicit drugs. However, the cutoff levels used by clinical labs are often arbitrarily set and may not reflect the urine drug concentrations of compliant patients. Our aim was to test the hypothesis that commonly used cutoffs for many prescribed and illicit drugs were set too high, and methods using these cutoffs may yield a considerable number of false-negative results. The goals of this study were to outline the way to analyze patient results and estimate a more appropriate cutoff, develop and validate a high sensitivity analytical method capable of quantitating drugs and metabolites at lower than the commonly used cutoffs, and determine the number of true positive results that would have been missed when using the common cutoffs. This was a retrospective study of urine specimens submitted for urine drug testing as part of the monitoring of prescription drug compliance described in chronic opioid therapy treatment guidelines. The study was set in a clinical toxicology laboratory, using specimens submitted for routine analysis by health care providers in the normal course of business. Lognormal distributions of test results were generated and fitted with a trendline to estimate the required cutoff level necessary to capture the normal distributions of each drug for the patient population study. A validated laboratory derived liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis capable of achieving the required cutoff levels was developed for each drug and/or metabolite. The study shows that a lognormal distribution of patient urine test results fitted with a trendline is appropriate for estimating the required cutoff levels needed to assess medication adherence. The study showed a wide variation in the false-negative rate, ranging from 1.5% to 94.3% across a range of prescribed and illicit drugs. The patient specimens were largely sourced from patients in either a long-term pain management program or in treatment for substance use disorder in the US. These specimens may not be representative of patients in other types of treatment or in countries with different approaches to these issues. The high-sensitivity method reduces false-negative results which could negatively impact patient care. Clinicians using less sensitive methods for detecting and quantifying drugs and metabolites in urine should exercise caution in assessing patient adherence using and changing the treatment plan based on those results. Urine drug testing, patient adherence, clinical toxicology, immunoassay, LC-MS, definitive drug testing, REMS, negative test results, false negative.
Ćwiklińska, Agnieszka; Dąbrowska, Hanna; Kowalski, Robert; Kuchta, Agnieszka; Kortas-Stempak, Barbara; Fijałkowska, Aleksandra; Bednarczuk, Gabriela; Jankowski, Maciej
2018-05-11
The ratio of albumin to creatinine (ACR) is an important parameter used for detection of albuminuria in patients with early kidney damage. The aim of the study was to evaluate the harmonization of ACR results among Polish participants in an international external quality assessment (EQA) program, and to evaluate the impact of albumin and creatinine analytical performance on the harmonization of ACR results. We analyzed 182 results of albumin, 202 of creatinine, and 180 of ACR obtained from Polish laboratories in an EQA program organized by Labquality. The dispersion of the results in surveys and percentage differences between the results and target values were calculated. Moreover, differences between method groups were assessed. The inter-laboratory coefficient of variation (CV) for ACR was 36%. Only 74% of results of Polish laboratories were within the target limits; for 11% of the results, an incorrect albuminuria category would have been reported. The inter-laboratory CV for albumin was 20%, 2.6-fold higher than for creatinine. Significant differences between method groups for albumin determination have been observed, even when the same measurement technique was used. The greatest difference between two groups was 23%, 2.5-fold greater in comparison to creatinine. There is an insufficient harmonization of ACR values among Polish laboratories, caused mainly by urine albumin analytical performance. Given the important role of ACR in the classification, monitoring and treatment of kidney damage, the harmonization of albumin measurements is crucial and urgently needed.
High throughput-screening of animal urine samples: It is fast but is it also reliable?
Kaufmann, Anton
2016-05-01
Advanced analytical technologies like ultra-high-performance liquid chromatography coupled to high resolution mass spectrometry can be used for veterinary drug screening of animal urine. The technique is sufficiently robust and reliable to detect veterinary drugs in urine samples of animals where the maximum residue limit of these compounds in organs like muscle, kidney, or liver has been exceeded. The limitations and possibilities of the technique are discussed. The most critical point is the variability of the drug concentration ratio between the tissue and urine. Ways to manage the false positive and false negatives are discussed. The capability to confirm findings and the possibility of semi-targeted analysis are also addressed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
De Clercq, Nathalie; Julie, Vanden Bussche; Croubels, Siska; Delahaut, Philippe; Vanhaecke, Lynn
2013-08-02
Due to their growth-promoting effects, the use of synthetic glucocorticoids is strictly regulated in the European Union (Council Directive 2003/74/EC). In the frame of the national control plans, which should ensure the absence of residues in food products of animal origin, in recent years, a higher frequency of prednisolone positive bovine urines has been observed. This has raised questions with respect to the stability of natural corticoids in the respective urine samples and their potential to be transformed into synthetic analogs. In this study, a ultra high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) methodology was developed to examine the stability of glucocorticoids in bovine urine under various storage conditions (up to 20 weeks) and to define suitable conditions for sample handling and storage, using an Orbitrap Exactive™. To this end, an extraction procedure was optimized using a Plackett-Burman experimental design to determine the key conditions for optimal extraction of glucocorticoids from urine. Next, the analytical method was successfully validated according to the guidelines of CD 2002/657/EC. Decision limits and detection capabilities for prednisolone, prednisone and methylprednisolone ranged, respectively, from 0.1 to 0.5μgL(-1) and from 0.3 to 0.8μgL(-1). For the natural glucocorticoids limits of detection and limits of quantification for dihydrocortisone, cortisol and cortisone ranged, respectively, from 0.1 to 0.2μgL(-1) and from 0.3 to 0.8μgL(-1). The stability study demonstrated that filter-sterilization of urine, storage at -80°C, and acidic conditions (pH 3) were optimal for preservation of glucocorticoids in urine and able to significantly limit degradation up to 20 weeks. Copyright © 2013 Elsevier B.V. All rights reserved.
Kavvalakis, Matthaios P; Tzatzarakis, Manolis N; Theodoropoulou, Eleftheria P; Barbounis, Emmanouil G; Tsakalof, Andreas K; Tsatsakis, Aristidis M
2013-11-01
Imidacloprid (IMI) is a relatively new neuro-active neonicotinoid insecticide and nowadays one of the largest selling insecticides worldwide. In the present study a LC–APCI–MS based method was developed and validated for the quantification of imidacloprid and its main metabolite 6-chloronicotinic acid (6- CINA) in urine and hair specimens. The method was tested in biomonitoring of intentionally exposed animals and subsequently applied for biomonitoring of Cretan urban and rural population. The developed analytical method comprises two main steps of analytes isolation from specimen (solid– liquid extraction with methanol for hair, liquid–liquid extraction with methanol for urine) and subsequent instrumental analysis by LC–APCI–MS. The developed method was applied for the monitoring of IMI and 6-ClNA in hair and urine of laboratory animals (rabbits) intentionally fed with insecticide at low or high doses (40 and 80 mg kg(-1) weight d(-1) respectively) for 24 weeks. The analytes were detected in the regularly acquired hair and urine specimens and their found levels were proportional to the feeding dose and time of exposure with the exception of slight decline of IMI levels in high dose fed rabbits after 24 weeks of feeding. This decline can be explained by the induction of IMI metabolizing enzymes by the substrate. After testing on animal models the method was applied for pilot biomonitoring of Crete urban (n = 26) and rural (n = 32) population. Rural but not urban population is exposed to IMI with 21 positive samples (65.6%) and found median concentration 0.03 ng mg(-1). Maximum concentration detected was 27 ng mg(-1)
Lu, Haihua; Yu, Jing; Wang, Jun; Wu, Linlin; Xiao, Hang; Gao, Rong
2016-04-15
Neuroactive metabolites in dopamine, serotonin and kynurenine metabolic pathways play key roles in several physiological processes and their imbalances have been implicated in the pathophysiology of a wide range of disorders. The association of these metabolites' alterations with various pathologies has raised interest in analytical methods for accurate quantification in biological fluids. However, simultaneous measurement of various neuroactive metabolites represents great challenges due to their trace level, high polarity and instability. In this study, an analytical method was developed and validated for accurately quantifying 12 neuroactive metabolites covering three metabolic pathways in youth urine by ultra performance liquid chromatography coupled to electrospray tandem high resolution mass spectrometry (UPLC-ESI-HRMS/MS). The strategy of dansyl chloride derivatization followed by solid phase extraction on C18 cartridges were employed to reduce matrix interference and improve the extraction efficiency. The reverse phase chromatographic separation was achieved with a gradient elution program in 20 min. The high resolution mass spectrometer (Q Exactive) was employed, with confirmation and quantification by Target-MS/MS scan mode. Youth urine samples collected from 100 healthy volunteers (Female:Male=1:1) were analyzed to explore the differences in metabolite profile and their turnover between genders. The results demonstrated that the UPLC-ESI-HRMS/MS method is sensitive and robust, suitable for monitoring a large panel of metabolites and for discovering new biomarkers in the medical fields. Copyright © 2016 Elsevier B.V. All rights reserved.
Glyphosate and aminomethylphosphonic acid are not detectable in human milk.
McGuire, Michelle K; McGuire, Mark A; Price, William J; Shafii, Bahman; Carrothers, Janae M; Lackey, Kimberly A; Goldstein, Daniel A; Jensen, Pamela K; Vicini, John L
2016-05-01
Although animal studies have shown that exposure to glyphosate (a commonly used herbicide) does not result in glyphosate bioaccumulation in tissues, to our knowledge there are no published data on whether it is detectable in human milk and therefore consumed by breastfed infants. We sought to determine whether glyphosate and its metabolite aminomethylphosphonic acid (AMPA) could be detected in milk and urine produced by lactating women and, if so, to quantify typical consumption by breastfed infants. We collected milk (n = 41) and urine (n = 40) samples from healthy lactating women living in and around Moscow, Idaho and Pullman, Washington. Milk and urine samples were analyzed for glyphosate and AMPA with the use of highly sensitive liquid chromatography-tandem mass spectrometry methods validated for and optimized to each sample matrix. Our milk assay, which was sensitive down to 1 μg/L for both analytes, detected neither glyphosate nor AMPA in any milk sample. Mean ± SD glyphosate and AMPA concentrations in urine were 0.28 ± 0.38 and 0.30 ± 0.33 μg/L, respectively. Because of the complex nature of milk matrixes, these samples required more dilution before analysis than did urine, thus decreasing the sensitivity of the assay in milk compared with urine. No difference was found in urine glyphosate and AMPA concentrations between subjects consuming organic compared with conventionally grown foods or between women living on or near a farm/ranch and those living in an urban or suburban nonfarming area. Our data provide evidence that glyphosate and AMPA are not detectable in milk produced by women living in this region of the US Pacific Northwest. By extension, our results therefore suggest that dietary glyphosate exposure is not a health concern for breastfed infants. This study was registered at clinicaltrials.gov as NCT02670278. © 2016 American Society for Nutrition.
Lech, Rodziewicz; Jolanta, MasŁOwiecka; Anna, Sadowska; Halina, Car
2017-10-08
Five thyreostats (TSs), namely tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil, were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) in positive electrospray ionization mode. Extraction and clean-up were achieved using a ChemElut cartridge with tert -butyl methyl ether, without a derivatization step. Separation was achieved on an Acquity UPLC SS T3 column. The mobile phase was acetonitrile and water containing 0.2% (v/v) formic acid. The mass spectrometer was operated in multiple reaction monitoring mode. Urine samples were spiked with TS solution at levels corresponding to 5, 10, 15, and 20 μg/L. The accuracy (internal standard corrected) ranged from 92% to 107%, with a repeatability precision (relative standard deviation, RSD) less than 15% for all five analytes. The RSDs within-laboratory reproducibility was less than 26%. The decision limits (CCα) and detection capabilities (CCβ) were obtained from a calibration curve and were in the ranges of 3.1-6.1 μg/L and 4.0-7.4 μg/L, respectively. The CCα and CCβ values were below the recommended concentration, which was set at 10 μg/L. The results show that the described method is suitable for the direct detection of TSs in bovine urine. This method can also be used to determine TSs in porcine urine.
Azzouz, Abdelmonaim; Rascón, Andrés J; Ballesteros, Evaristo
2016-02-05
A highly sensitive gas chromatography-mass spectrometry (GC-MS) method for the determination of endocrine disrupting chemicals (EDCs) including parabens, alkylphenols, phenylphenols, bisphenol A and triclosan in human breast milk, blood and urine samples is proposed. Blood and milk require a pretreatment to remove proteins and other substances potentially interfering with the continuous solid-phase extraction (SPE) system used; on the other hand, urine samples can be directly introduced into the system after filtering. Analytes are retained on a LiChrolut EN column and derivatized by silylation following elution with acetonitrile. The resulting trimethylsilyl derivatives are determined by GC-MS. The proposed method exhibited good linearity (r(2)>0.995) for all target EDCs over the concentration range 0.7-10,000ng/l in urine, and 3.3-50,000ng/l in blood and milk. Also, it provided low limits of detection (0.2-1.8ng/l in urine, and 1.0-9.0ng/l in blood and milk), good precision (relative standard deviations less than 7%) and recoveries from 86 to 104%. A total of 24 human fluid samples were analyzed and most found to contain some target EDC at concentrations from 0.10 to 14μg/l. Copyright © 2015 Elsevier B.V. All rights reserved.
Analysis of cannabis in oral fluid specimens by GC-MS with automatic SPE.
Choi, Hyeyoung; Baeck, Seungkyung; Kim, Eunmi; Lee, Sooyeun; Jang, Moonhee; Lee, Juseon; Choi, Hwakyung; Chung, Heesun
2009-12-01
Methamphetamine (MA) is the most commonly abused drug in Korea, followed by cannabis. Traditionally, MA analysis is carried out on both urine and hair samples and cannabis analysis in urine samples only. Despite the fact that oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing, its application has not been expanded to drug analysis in Korea. Oral fluid is easy to collect and handle and can provide an indication of recent drug abuse. In this study, we present an analytical method using GC-MS to determine tetrahydrocannabinol (THC) and its main metabolite 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in oral fluid. The validated method was applied to oral fluid samples collected from drug abuse suspects and the results were compared with those in urine. The stability of THC and THC-COOH in oral fluid stored in different containers was also investigated. Oral fluid specimens from 12 drug abuse suspects, submitted by the police, were collected by direct expectoration. The samples were screened with microplate ELISA. For confirmation they were extracted using automated SPE with mixed-mode cation exchange cartridge, derivatized and analyzed by GC-MS using selective ion monitoring (SIM). The concentrations ofTHC and THC-COOH in oral fluid showed a large variation and the results from oral fluid and urine samples from cannabis abusers did not show any correlation. Thus, detailed information about time interval between drug use and sample collection is needed to interpret the oral fluid results properly. In addition, further investigation about the detection time window ofTHC and THC-COOH in oral fluid is required to substitute oral fluid for urine in drug testing.
Sana, Theodore R; Roark, Joseph C; Li, Xiangdong; Waddell, Keith; Fischer, Steven M
2008-09-01
In an effort to simplify and streamline compound identification from metabolomics data generated by liquid chromatography time-of-flight mass spectrometry, we have created software for constructing Personalized Metabolite Databases with content from over 15,000 compounds pulled from the public METLIN database (http://metlin.scripps.edu/). Moreover, we have added extra functionalities to the database that (a) permit the addition of user-defined retention times as an orthogonal searchable parameter to complement accurate mass data; and (b) allow interfacing to separate software, a Molecular Formula Generator (MFG), that facilitates reliable interpretation of any database matches from the accurate mass spectral data. To test the utility of this identification strategy, we added retention times to a subset of masses in this database, representing a mixture of 78 synthetic urine standards. The synthetic mixture was analyzed and screened against this METLIN urine database, resulting in 46 accurate mass and retention time matches. Human urine samples were subsequently analyzed under the same analytical conditions and screened against this database. A total of 1387 ions were detected in human urine; 16 of these ions matched both accurate mass and retention time parameters for the 78 urine standards in the database. Another 374 had only an accurate mass match to the database, with 163 of those masses also having the highest MFG score. Furthermore, MFG calculated a formula for a further 849 ions that had no match to the database. Taken together, these results suggest that the METLIN Personal Metabolite database and MFG software offer a robust strategy for confirming the formula of database matches. In the event of no database match, it also suggests possible formulas that may be helpful in interpreting the experimental results.
Ocque, Andrew J; Stubbs, Jason R; Nolin, Thomas D
2015-05-10
A simple, sensitive, and precise ultra-high performance liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of trimethylamine N-oxide, choline, and betaine in human plasma and urine. Sample preparation involved protein precipitation with methanol containing internal standards. Chromatographic separation was achieved using an Acquity BEH Amide (2.1mm×50mm, 1.7μm) analytical column with gradient elution of solvent A (10mM ammonium formate, pH 3.5) and solvent B (acetonitrile). The flow rate was 0.4mL/min and the total run time was 5min. Detection of analytes was performed using heated electrospray ionization (positive mode) and selected reaction monitoring. Excellent linearity was observed over the standard curve concentration ranges of 0.010-5.00μg/mL (plasma) and 1.00-150μg/mL (urine) for all analytes. The intra- and inter-day accuracy and precision for all quality controls were within ±10%. Excellent recovery was observed. The method is rapid, accurate and reproducible, and was successfully applied to a pilot study of markers of atherosclerosis in patients with kidney disease who underwent successful kidney transplantation. Copyright © 2015 Elsevier B.V. All rights reserved.
Liu, Yan-Ming; Shi, Yan-Mei; Liu, Zhuan-Li; Peng, Long-Fei
2010-05-01
A sensitive approach for the simultaneous determination of tilmicosin, erythromycin ethylsuccinate and clindamycin was developed by CE coupled with electrochemiluminescence detection with ionic liquid. The parameters for CE, electrochemiluminescence detection and the effect of ionic liquid were investigated systematically. The three analytes were well separated and detected within 8 min. The limits of detection (S/N=3) of tilmicosin, erythromycin ethylsuccinate and clindamycin are 3.4x10(-9), 2.3x10(-8) and 1.3x10(-8) mol/L, respectively. The precisions (RSD%) of the peak area and the migration time are from 0.8 to 1.5% and from 0.2 to 0.5% within a day and from 1.8 to 2.7% and from 0.6 to 0.8% in 3 days, respectively. The limits of quantitation (S/N=10) of tilmicosin, erythromycin ethylsuccinate and clindamycin are 3.2x10(-8), 2.9x10(-7) and 9.1x10(-8) mol/L in human urines and 5.5x10(-8), 3.2x10(-7) and 2.1x10(-7) mol/L in milk samples, respectively. The recoveries of three analytes at different concentration levels in urine, milk and drugs are between 90.0 and 104.7%. The proposed method was successfully applied to the determination of three analytes in human urine, milk and drugs.
NASA Technical Reports Server (NTRS)
Song, Q.; Putcha, L.; Harm, D. L. (Principal Investigator)
2001-01-01
A chromatographic method for the quantitation of promethazine (PMZ) and its three metabolites in urine employing on-line solid-phase extraction and column-switching has been developed. The column-switching system described here uses an extraction column for the purification of PMZ and its metabolites from a urine matrix. The extraneous matrix interference was removed by flushing the extraction column with a gradient elution. The analytes of interest were then eluted onto an analytical column for further chromatographic separation using a mobile phase of greater solvent strength. This method is specific and sensitive with a range of 3.75-1400 ng/ml for PMZ and 2.5-1400 ng/ml for the metabolites promethazine sulfoxide, monodesmethyl promethazine sulfoxide and monodesmethyl promethazine. The lower limits of quantitation (LLOQ) were 3.75 ng/ml with less than 6.2% C.V. for PMZ and 2.50 ng/ml with less than 11.5% C.V. for metabolites based on a signal-to-noise ratio of 10:1 or greater. The accuracy and precision were within +/- 11.8% in bias and not greater than 5.5% C.V. in intra- and inter-assay precision for PMZ and metabolites. Method robustness was investigated using a Plackett-Burman experimental design. The applicability of the analytical method for pharmacokinetic studies in humans is illustrated.
Schettgen, Thomas; Dewes, Petra; Kraus, Thomas
2016-08-01
Synthetic pyrethroids are highly effective, widespread insecticides applied worldwide for different purposes. Among the possible sources of exposure for the general population, pyrethroid residues in food and their prominent use for the conservation of wool carpets or in indoor pest control might play a major role. On the basis of previous works, we have developed and validated a highly sensitive and specific GC/MS/MS-method to simultaneously quantify the metabolites of the most common synthetic pyrethroids in urine, namely cis- and trans-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylic acid (DCCA), cis-(2,2-dibromovinyl)-2,2-dimethylcyclopropanecarboxylic acid (DBCA), 4-fluoro-3-phenoxybenzoic acid (F-PBA), 3-phenoxybenzoic acid (3-PBA) as well as the metabolites cis-3-(2-chloro-3,3,3-trifluoroprop-1-enyl)-2,2-dimethyl-cyclopropanecarboxylic acid (ClF3CA, λ-cyhalothrin/bifenthrin), 4-chloro-α-isopropylbenzene acetic acid (CPBA, esfenvalerate), and 2-methyl-3-phenylbenzoic acid (MPB, bifenthrin). After acidic hydrolysis to cleave conjugates in urine, the analytes are subjected to a pH-controlled extraction into n-hexane. After concentration, the analytes are derivatised using MTBSTFA and finally quantified by GC/MS/MS in EI-mode using d6-trans-DCCA and (13)C6-3-PBA as internal standards. The limit of quantification for these metabolites was 0.01 μg/L urine. Precision within and between series was determined to range between 1.6 and 10.7 % using a native quality control sample as well as a urine sample spiked with 0.3 μg/L of the analytes. To investigate possible background excretions, we analysed spot urine samples of 38 persons of the general population in a pilot study. cis- and trans-DCCA as well as 3-PBA could be quantified in every urine sample investigated, while MPB and F-PBA could only be detected in two samples. The median levels for excretion of cis-DCCA, trans-DCCA, 3-PBA, ClF3CA, DBCA, CPBA, F-PBA and MPA were 0.08, 0.17, 0.22, 0.04, 0.04, <0.01, <0.01 and < 0.01 μg/L urine, respectively. The excretion of metabolites revealed excellent correlations between cyclopropane carboxylic acids and 3-PBA. Our method is highly suitable for human biomonitoring of exposures to synthetic pyrethroids in environmental medicine. Remarkable are the high detection rates for the metabolites ClF3CA (90 %) and CPBA (40 %), proving that their parent pyrethroids have entered the market in Germany.
Fidani, M; Gamberini, M C; Pasello, E; Palazzoli, F; De Iuliis, P; Montana, M; Arioli, F
2009-01-01
Proper storage conditions of biological samples are fundamental to avoid microbiological contamination that can cause chemical modifications of the target analytes. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method through direct injection of diluted samples, without prior extraction, was used to evaluate the stability of phase II metabolites of boldenone and testosterone (glucuronides and sulphates) in intentionally poorly stored equine urine samples. We also considered the stability of some deuterated conjugated steroids generally used as internal standards, such as deuterated testosterone and epitestosterone glucuronides, and deuterated boldenone and testosterone sulphates. The urines were kept for 1 day at room temperature, to mimic poor storage conditions, then spiked with the above steroids and kept at different temperatures (-18 degrees C, 4 degrees C, room temperature). It has been possible to confirm the instability of glucuronide compounds when added to poorly stored equine urine samples. In particular, both 17beta- and 17alpha-glucuronide steroids were exposed to hydrolysis leading to non-conjugated steroids. Only 17beta-hydroxy steroids were exposed to oxidation to their keto derivatives whereas the 17alpha-hydroxy steroids were highly stable. The sulphate compounds were completely stable. The deuterated compounds underwent the same behaviour as the unlabelled compounds. The transformations were observed in urine samples kept at room temperature and at a temperature of 4 degrees C (at a slower rate). No modifications were observed in frozen urine samples. In the light of the latter results, the immediate freezing at -18 degrees C of the collected samples and their instant analysis after thawing is the proposed procedure for preventing the transformations that occur in urine, usually due to microbiological contamination. (c) 2008 John Wiley & Sons, Ltd.
Tanner, Julie-Anne; Novalen, Maria; Jatlow, Peter; Huestis, Marilyn A.; Murphy, Sharon E.; Kaprio, Jaakko; Kankaanpää, Aino; Galanti, Laurence; Stefan, Cristiana; George, Tony P.; Benowitz, Neal L.; Lerman, Caryn; Tyndale, Rachel F.
2015-01-01
Background The highly genetically variable enzyme CYP2A6 metabolizes nicotine to cotinine (COT) and COT to trans-3′-hydroxycotinine (3HC). The nicotine metabolite ratio (NMR, 3HC/COT) is commonly used as a biomarker of CYP2A6 enzymatic activity, rate of nicotine metabolism, and total nicotine clearance; NMR is associated with numerous smoking phenotypes, including smoking cessation. Our objective was to investigate the impact of different measurement methods, at different sites, on plasma and urinary NMR measures from ad libitum smokers. Methods Plasma (n=35) and urine (n=35) samples were sent to eight different laboratories, which employed similar and different methods of COT and 3HC measurements to derive the NMR. We used Bland-Altman analysis to assess agreement, and Pearson correlations to evaluate associations, between NMR measured by different methods. Results Measures of plasma NMR were in strong agreement between methods according to Bland-Altman analysis (ratios 0.82–1.16) and were highly correlated (all Pearson r>0.96, P<0.0001). Measures of urinary NMR were in relatively weaker agreement (ratios 0.62–1.71) and less strongly correlated (Pearson r values of 0.66–0.98, P<0.0001) between different methods. Plasma and urinary COT and 3HC concentrations, while weaker than NMR, also showed good agreement in plasma, which was better than in urine, as was observed for NMR. Conclusions Plasma is a very reliable biological source for the determination of NMR, robust to differences in these analytical protocols or assessment site. Impact Together this indicates a reduced need for differential interpretation of plasma NMR results based on the approach used, allowing for direct comparison of different studies. PMID:26014804
Pires, F; Arcos-Martinez, M Julia; Dias-Cabral, A Cristina; Vidal, Juan C; Castillo, Juan R
2018-04-17
Human cytomegalovirus (HCMV) is a herpes virus that can cause severe infections. Still, the available methods for its diagnostic have the main disadvantage of requiring long time to be performed. In this work, a simple magnetic particle-based enzyme immunoassay (mpEIA) for the quantification of glycoprotein B of Human cytomegalovirus (gB-HCMV) in urine samples is proposed. The immunosensor scheme is based on the analyte protein gB-HCMV sandwiched between a primary monoclonal antibody, (MBs-PrG-mAb1), and a secondary anti-gB-HCMV antibody labelled with Horseradish peroxidase (Ab2-HRP) to allow spectrophotometric detection. The mpEIA analytical performance was tested in urine samples, showing a linear dependence between gB-HCMV concentration and the absorbance signal at 450 nm in a range of concentrations from 90 to 700 pg mL -1 . The calculated detection limits for gB-HCMV were 90 ± 2 pg mL -1 and the RSD was about 6.7% in urine samples. The immunosensor showed good selectivity against other viruses from Herpesviridae family, namely varicella zoster and Epstein Barr viruses. The recoveries of spiked human urine samples at 0.30-0.50 ng mL -1 concentration levels of gB-HCMV ranged between 91 to 105%. The proposed mpEIA method was validated following the guidelines of the European Medicines Agency (EMEA-2014), and allows rapid, successful and easy quantification of gB-HCMV in urine samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Determination of lipoic acid in human urine by capillary zone electrophoresis.
Kubalczyk, Paweł; Głowacki, Rafał
2017-07-01
Fast, simple, and accurate CE method enabling determination of lipoic acid (LA) in human urine has been developed and validated. LA is a disulfide-containing natural compound absorbed from the organism's diet. Due to powerful antioxidant activity, LA has been used for prevention and treatment of various diseases and disorders, e.g. cardiovascular diseases, neurodegenerative disorders, and cancer. The proposed analytical procedure consists of liquid-liquid sample extraction, reduction of LA with tris(2-carboxyethyl)phosphine, derivatization with 1-benzyl-2-chloropyridinium bromide (BCPB) followed by field amplified sample injection stacking, capillary zone electrophoresis separation, and ultraviolet-absorbance detection of LA-BCPB derivative at 322 nm. Effective baseline electrophoretic separation was achieved within 6 min under the separation voltage of 20 kV (∼80 μA) using a standard fused-silica capillary (effective length 51.5 cm, 75 μm id) and BGE consisted of 0.05 mol/L borate buffer adjusted to pH 9. The experimentally determined limit of detection for LA in urine was 1.2 μmol/L. The calibration curve obtained for LA in urine showed linearity in the range 2.5-80 μmol/L, with R 2 0.9998. The relative standard deviation of the points of the calibration curve was lower than 10%. The analytical procedure was successfully applied to analysis of real urine samples from seven healthy volunteers who received single 100 mg dose of LA. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liu, Chang-Cai; Liu, Shi-Lei; Xi, Hai-Ling; Yu, Hui-Lan; Zhou, Shi-Kun; Huang, Gui-Lan; Liang, Long-Hui; Liu, Jing-Quan
2017-04-07
Four HD urinary metabolites including hydrolysis metabolite thiodiglycol (TDG), glutathione-derived metabolite 1,1'-sulfonylbis[2-S-(N-acetylcysteinyl)ethane] (SBSNAE), as well as the β-lyase metabolites 1,1'-sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE) and 1-methylsulfinyl-2-[2-(methylthio) ethylsulfonyl]ethane (MSMTESE) are considered as important biomarkers for short-term retrospective detection of HD exposure. In this study, a single method for simultaneous quantification of the four HD metabolites in urine samples was developed using ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The four urinary metabolites were simultaneously extracted from urinary samples using a solid phase extraction (SPE) method with high extraction recoveries for all four metabolites varied in the range of 71.1-103% followed by UHPLC-MS/MS analysis. The SPE is simple and high effective only requiring 0.1mL of urinary samples and 0.5h time consuming. The problem of previous co-elution of TDG and SBSNAE in UHPLC was well solved, and complete separation of TDG, SBSNAE, SBMSE and MSMTESE from SPE-processed urine matrix was obtained to increase specificity and sensitivity. A full method validation was performed for each analyte in urine matrix. The linear range of calibration curves for the four analytes were respectively from 0.50-500ngmL -1 for TDG and SBSNAE, 0.05-500ngmL -1 for SBMSE and MSMTESE with coefficient of determination value (R 2 ) ≥0.990. The limit of detection was 0.25ngmL -1 for TDG and SBSNAE, 0.01ngmL -1 for SBMSE and MSMTESE spiked in normal urine. The intra/inter-day precision for each analyte at three QC levels had relative standard deviation (%RSD) of ≤10.3%, and the intra/inter-day accuracy ranged between 88.0-108%. This developed method allows for simultaneous and trace measurement of four HD urinary metabolites within one single determination with the lowest usage amount of urine samples over all previous methods This study provides a useful tool for early diagnosis and monitoring of HD poisoning for medical treatment with high confidence, avoiding the need for application of several analysis methods. Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection.
De Rosa, Rita; Grosso, Shamanta; Bruschetta, Graziano; Avolio, Manuela; Stano, Paola; Modolo, Maria Luisa; Camporese, Alessandro
2010-08-05
Urine culture is one of the most frequently requested tests in microbiology, and it represents the gold standard for the diagnosis of UTIs. Considering the high prevalence of negative results and the long TAT of the culture test, the use of a rapid and reliable screening method is becoming more and more important, as it reduces the workload, the TAT of negative results, and above all, unnecessary antibiotic prescription. The Sysmex UF1000i is a new urine flow cytometry analyzer capable of quantifying urinary particles, including BACT, WBCs, and YLCs. To evaluate the analytical performance of the UF1000i as a method for ruling out UTIs, we examined 1349 urine samples and compared the UF1000i results with standard urine culture results. With instrument cut-off values of 170BACTx10(6)/L and 150WBCsx10(6)/L, we obtained a sensitivity of 98.8%, a specificity of 76.5%, a NPV of 99.5%, and four false negative results (1.2%), avoiding the culture of 57.1% of samples. The Sysmex UF1000i was capable of improving the efficiency of a routine microbiology laboratory by processing 100samples/h and providing negative results in a few minutes, thus reducing unnecessary testing with an acceptable number of false negative results. In addition, the preliminary evaluation of B_FSC and B_FLH parameters from bacteria histograms seems to be useful for the distinction of bacterial strains detected (Gram-negatives versus Gram-positives). In fact when B_FSC was less than 30 ch, it allowed the distinction of Gram-negative bacteria in 97% of the samples. Copyright 2010 Elsevier B.V. All rights reserved.
The Spanish external quality assessment scheme for mercury in urine.
Quintana, M J; Mazarrasa, O
1996-01-01
In 1986 the Instituto Nacional de Seguridad e Higiene en el Trabajo (INSHT), established the "Programa interlaboratorios de control de calidad de mercurio en orina (PICC-HgU)". The operation of this scheme is explained, criteria for evaluation of laboratory performance are defined and some results obtained are reviewed. Since the scheme started, an improvement in the overall performance of laboratories has been observed. The differences in the analytical methods used by laboratories do not seem to have a clear influence on the results.
Aresta, Antonella; Monaci, Linda; Zambonin, Carlo Giorgio
2002-06-01
An SPME-HPLC-UV method for the determination of delorazepam, a representative benzodiazepine, in spiked human urine samples was developed for the first time. The performances of two commercially available fibers, a carbowax/templated resin (Carbowax/TPR-100) and a polydimethylsiloxane/divinylbenzene (PDMS/DVB), were compared, indicating the latter as the most suitable for urine samples analysis. All the aspects influencing adsorption (extraction time, pH, temperature, salt addition) and desorption (desorption and injection time, desorption solvent mixture composition) of the analyte on the fiber have been investigated. In particular, short extraction times were necessary to reach the equilibrium and very short desorption times were employed. The procedure required simple sample pre-treatment and was able to detect 5 ng/ml in spiked urine, regardless of the complexity of the matrix.
Fernández, María del Mar Ramírez; Wille, Sarah M R; Samyn, Nele; Wood, Michelle; López-Rivadulla, Manuel; De Boeck, Gert
2009-01-01
An automated online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of amphetamines in blood and urine was developed and validated. Chromatographic separation was achieved on a Nucleodur Sphinx RP column with an LC gradient (a mixture of 10 mM ammonium formate buffer and acetonitrile), ensuring the elution of amphetamine, methamphetamine, MDMA, MDA, MDEA, PMA, and ephedrine within 11 min. The method was fully validated, according to international guidelines, using only 100 and 50 microL of blood and urine, respectively. The method showed an excellent intra- and interassay precision (relative standard deviation < 11.2% and bias < 13%) for two external quality control samples (QC) for both matrices and three and two 'in house' QCs for blood and urine, respectively. Responses were linear over the investigated range (r(2) > 0.99, 2.5-400 microg/L for blood and 25-1000 microg/L for urine). Limits of quantification were determined to be 2.5 and 25 microg/L for blood and urine, respectively. Limits of detection ranged from 0.05 to 0.5 microg/L for blood and 0.25 to 2.5 microg/L for urine, depending on the compound. Furthermore, the analytes and the processed samples were demonstrated to be stable (in the autosampler for at least 72 h and after three freeze/thaw cycles), and no disturbing matrix effects were observed for all compounds. Moreover, no carryover was observed after the analysis of high concentration samples (15,000 microg/L). The method was subsequently applied to authentic blood and urine samples obtained from forensic cases, which covered a broad range of concentrations. The validation results and actual sample analyses demonstrated that this method is rugged, precise, accurate, and well-suited for routine analysis as more than 72 samples are analyzed non-stop in 24 h with minimum sample handling. The combination of the high-throughput online SPE and the well-known sensitivity and selectivity assured by MS-MS resulted in the elimination of the bottleneck associated with the sample preparation requirements and provided increased sensitivity, accuracy, and precision.
Bertholf, Roger L; Johannsen, Laura M; Reisfield, Gary M
2015-01-01
Urine drug testing (UDT) is an emerging standard of care in the evaluation and treatment of chronic non-cancer pain patients with opioid analgesics. UDT may be used both to verify adherence with the opioid analgesic regimen and to monitor abstinence from non-prescribed or illicit controlled substances. In the former scenario, it is vital to determine whether the drug is present in the urine, even at low concentrations, because failure to detect the drug may lead to accusations of opioid abuse or diversion. Opiate immunoassays typically are developed to detect morphine and are most sensitive to morphine and codeine. Although many opiate immunoassays also detect hydrocodone (HC) and/or hydromorphone (HM), sensitivities for these analytes are often much lower, increasing the possibility of negative screening results when the drug is present in the urine. We selected 112 urine specimens from patients who had been prescribed HC or hydromorphone but were presumptive negative by the Roche Online DAT Opiate II™ urine drug screening assay, which is calibrated to 300 ng/mL morphine. Using a GC/MS confirmatory method with a detection limit of 50 ng/mL both for HC and for HM, one or both of these opiates were detected in 81 (72.3%) of the urine specimens. Examination of the raw data from these presumptive negative opiate screens revealed that, in many cases, the turbidity signal was greater than the signal obtained for the negative control, but less than the signal for the 300 ng/mL (morphine) threshold calibrator. A receiver operating characteristic curve generated for the reciprocal of the ratio of turbidity measurements in the patient specimens and negative (drug-free) controls, against the presence or absence of HC and/or HM by confirmatory analyses, produced an area under the curve of 0.910. We conclude that this opiate immunoassay has sufficient sensitivity to detect HC and/or HM in some urine specimens that screen presumptive negative for these commonly prescribed opiates at the established threshold. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Bagheri, Hasan; Zavareh, Alireza Fakhari; Koruni, Mohammad Hossein
2016-03-01
In the present study, graphene oxide reinforced two-phase electromembrane extraction (EME) coupled with gas chromatography was applied for the determination of methamphetamine as a model analyte in biological samples. The presence of graphene oxide in the hollow fiber wall can increase the effective surface area, interactions with analyte and polarity of support liquid membrane that leads to an enhancement in the analyte migration. To investigate the influence of the presence of graphene oxide in the support liquid membrane on the extraction efficiency, a comparative study was performed between graphene oxide and graphene oxide/EME methods. The extraction parameters such as type of organic solvent, pH of the donor phase, stirring speed, time, voltage, salt addition and the concentration of graphene oxide were optimized. Under the optimum conditions, the proposed microextraction technique provided low limit of detection (2.4 ng/mL), high preconcentration factor (195-198) and high relative recovery (95-98.5%). Finally, the method was successfully employed for the determination of methamphetamine in urine and hair samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A Meta-Analysis of Studies of Treatments for Feline Urine Spraying
Mills, Daniel S.; Redgate, Sarah E.; Landsberg, Gary M.
2011-01-01
Feline urine spraying inside the home is a common problem behaviour that owners seek advice for from veterinarians. Individual trials relating to a variety of interventions produce variable results, and to date, no consensus on the value of different treatments has emerged. This study therefore aimed to meta-analyse, current data from appropriate published clinical trials that evaluate treatments for feline urine spraying. Inclusion and exclusion criteria for study selection were predefined and methodological quality was assessed by two independent reviewers. Ten studies in nine publications that either evaluated pharmacotherapy or pheromonatherapy (the use of a synthetic analogue of the F3 facial fraction in the cat) were suitable for analysis. There was a significant (P<0.001) association between the use of any intervention and the number of cats that ceased or reduced urine spraying by at least 90%. Analysis by intervention type indicated that fluoxetine, clomipramine and pheromonatherapy may each assist in managing urine spraying beyond a placebo based intervention. This is the first time meta-analytical techniques have been used and reported to evaluate the efficacy of interventions used in veterinary behavioural medicine, and it has established confidence in the value of both conventional treatments (pharmacotherapy) and a more recently developed treatment modality (pheromonatherapy) as an adjunct to the management of this problem. It is suggested that future research into treatment efficacy for this problem uses the benchmark standard of randomised, controlled trials lasting for at least 8 weeks, with the outcome criteria of cessation of feline urine spraying or reduction by at least 90%. PMID:21525994
He, Xiao-Mei; Zhu, Gang-Tian; Yin, Jia; Zhao, Qin; Yuan, Bi-Feng; Feng, Yu-Qi
2014-07-18
In the current study, polystyrene/oxidized carbon nanotubes (PS/OCNTs) film was prepared and applied as both an adsorbent of thin film microextraction (TFME) and matrix for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for the first time. The uniform size of PS/OCNTs film with OCNTs evenly and firmly immobilized in PS was obtained by electrospinning. And a novel TFME device was developed using the prepared PS/OCNTs film to enrich benzo[a]pyrene (BaP) from water, and also BaP and 1-hydroxypyrene (1-OHP) from urine sample. Then the extracted analytes on the PS/OCNTs film were directly applied to MALDI-MS analysis with PS/OCNTs film as the MALDI matrix. Our results show that PS/OCNTs film is a good TFME adsorbent toward the analytes and an excellent matrix for the sensitive determination of BaP and 1-OHP using MALDI-TOF-MS. The employment of PS/OCNTs as the matrix for MALDI can effectively avoid the large variation of signal intensity normally resulting from heterogeneous distribution of the adsorbed analyte on matrix layer, which therefore significantly improve spot-to-spot reproducibility. The introduction of PS in the film can prevent OCNTs from flying out of MALDI plate to damage the equipment. In addition, PS/OCNTs film also largely extended the duration of ion signal of target analyte compared to OCNTs matrix. The developed method was further successfully used to quantitatively determine BaP in environmental water and 1-OHP in urine samples. The results show that BaP and 1-OHP could be easily detected at concentrations of 50pgmL(-1) and 500pgmL(-1), respectively, indicating the high detection sensitivity of this method. For BaP analysis, the linear range was 0.1-20ngmL(-1) with a correlation coefficient of 0.9970 and the recoveries were in the range of 81.3 to 123.4% with the RSD≤8.5% (n=3); for urinary 1-OHP analysis, the linear range was 0.5-20ngmL(-1) with a correlation coefficient of 0.9937 and the recoveries were in the range of 79.2 to 103.4% with the RSD≤7.6% (n=3). Taken together, the developed method provides a simple, rapid, cost-effective and high-throughput approach for the analysis of BaP in environmental water and endogenous 1-OHP in urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Ma, Ruiyang; Hao, Lin; Wang, Junmin; Wang, Chun; Wu, Qiuhua; Wang, Zhi
2016-09-01
An iron-embedded porous carbon material (MIL-53-C) was fabricated by the direct carbonization of MIL-53. The MIL-53-C possesses a high surface area and good magnetic behavior. The structure, morphology, magnetic property, and porosity of the MIL-53-C were studied by scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and N2 adsorption. With the use of MIL-53-C as the magnetic solid-phase extraction adsorbent, a simple and efficient method was developed for the magnetic solid-phase extraction of three hormones from water and human urine samples before high-performance liquid chromatography with UV detection. The developed method exhibits a good linear response in the range of 0.02-100 ng/mL for water and 0.5-100 ng/mL for human urine samples, respectively. The limit of detection (S/N = 3) for the analytes was 0.005-0.01 ng/mL for water sample and 0.1-0.3 ng/mL for human urine sample. The limit of quantification (S/N = 10) of the analytes were in the range of 0.015-0.030 and 0.3-0.9 ng/mL, respectively. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Determination of 232Th in urine by ICP-MS for individual monitoring purposes.
Baglan, N; Cossonnet, C; Ritt, J
2001-07-01
Thorium is naturally occurring in various ores used for industrial purposes and has numerous applications. This paper sets out to investigate urine analysis as a suitable monitoring approach for workers potentially exposed to thorium. Due to its biokinetic behavior and its low solubility, urinary concentrations are generally very low, requiring therefore high sensitivity analytical methods. An analytical procedure has been developed for detecting 232Th concentrations of below 1 mBq L(-1) quickly and easily. Due to the long half-life (1.41 x 10(10) y) of 232Th, the potential of a procedure based on urine sample dilution and ICP-MS (inductively coupled plasma-mass spectrometry) measurement was investigated first. Two dilution factors were chosen: 100, which is more suitable for long-term measurement trials, and 20, which increases sensitivity. It has been shown that a 100-fold dilution can be used to measure concentrations of below 1 mBq L(-1), whereas a 20-fold one can be used to reach concentrations of below 0.06 mBq L(-1). Then, on the basis of the limitation of the procedure based on urine dilution, the suitable field of application for the different procedures (100-fold and 20-fold dilution and also a chemical purification followed by an ICP-MS measurement) was determined in relation to monitoring objectives.
Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M
2017-04-08
Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.
Scholz, Karoline; Dekant, Wolfgang; Völkel, Wolfgang; Pähler, Axel
2005-12-01
A sensitive and specific liquid chromatography-mass spectrometry (LC-MS) method based on the combination of constant neutral loss scans (CNL) with product ion scans was developed on a linear ion trap. The method is applicable for the detection and identification of analytes with identical chemical substructures (such as conjugates of xenobiotics formed in biological systems) which give common CNLs. A specific CNL was observed for thioethers of N-acetyl-L-cysteine (mercapturic acids, MA) by LC-MS/MS. MS and HPLC parameters were optimized with 16 MAs available as reference compounds. All of these provided a CNL of 129 Da in the negative-ion mode. To assess sensitivity, a multiple reaction monitoring (MRM) mode with 251 theoretical transitions using the CNL of 129 Da combined with a product ion scan (IDA thMRM) was compared with CNL combined with a product ion scan (IDA CNL). An information-dependent acquisition (IDA) uses a survey scan such as MRM (multiple reaction monitoring) to generate "informations" and starting a second acquisition experiment such as a product ion scan using these "informations." Th-MRM means calculated transitions and not transitions generated from an available standard in the tuning mode. The product ion spectra provide additional information on the chemical structure of the unknown analytes. All MA standards were spiked in low concentrations to rat urines and were detected with both methods with LODs ranging from 60 pmol/mL to 1.63 nmol/mL with IDA thMRM. The expected product ion spectra were observed in urine. Application of this screening method to biological samples indicated the presence of a number of MAs in urine of unexposed rats, and resulted in the identification of 1,4-dihydroxynonene mercapturic acid as one of these MAs by negative and positive product ion spectra. These results show that the developed methods have a high potential to serve as both a prescreen to detect unknown MAs and to identify these analytes in complex matrix.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horton, Megan K., E-mail: megan.horton@mssm.edu; Blount, Benjamin C.; Valentin-Blasini, Liza
Background: Adequate maternal thyroid function during pregnancy is necessary for normal fetal brain development, making pregnancy a critical window of vulnerability to thyroid disrupting insults. Sodium/iodide symporter (NIS) inhibitors, namely perchlorate, nitrate, and thiocyanate, have been shown individually to competitively inhibit uptake of iodine by the thyroid. Several epidemiologic studies examined the association between these individual exposures and thyroid function. Few studies have examined the effect of this chemical mixture on thyroid function during pregnancy Objectives: We examined the cross sectional association between urinary perchlorate, thiocyanate and nitrate concentrations and thyroid function among healthy pregnant women living in New Yorkmore » City using weighted quantile sum (WQS) regression. Methods: We measured thyroid stimulating hormone (TSH) and free thyroxine (FreeT4) in blood samples; perchlorate, thiocyanate, nitrate and iodide in urine samples collected from 284 pregnant women at 12 (±2.8) weeks gestation. We examined associations between urinary analyte concentrations and TSH or FreeT4 using linear regression or WQS adjusting for gestational age, urinary iodide and creatinine. Results: Individual analyte concentrations in urine were significantly correlated (Spearman's r 0.4–0.5, p<0.001). Linear regression analyses did not suggest associations between individual concentrations and thyroid function. The WQS revealed a significant positive association between the weighted sum of urinary concentrations of the three analytes and increased TSH. Perchlorate had the largest weight in the index, indicating the largest contribution to the WQS. Conclusions: Co-exposure to perchlorate, nitrate and thiocyanate may alter maternal thyroid function, specifically TSH, during pregnancy. - Highlights: • Perchlorate, nitrate, thiocyanate and iodide measured in maternal urine. • Thyroid function (TSH and Free T4) measured in maternal blood. • Weighted quantile sum (WQS) regression examined complex mixture effect. • WQS identified an inverse association between the exposure mixture and maternal TSH. • Perchlorate indicated as the ‘bad actor’ of the mixture.« less
Gao, Guihua; Li, Sijia; Li, Shuo; Wang, Yudan; Zhao, Pan; Zhang, Xiangyu; Hou, Xiaohong
2018-04-01
In this work, computational and experimental methods were used to study the adsorption of estrogens and glucocorticoids on metal-organic frameworks (MOFs). Computer-aided molecular simulation was applied to predict the adsorption of eight analytes on four MOFs (MIL-101(Cr), MIL-100(Fe), MIL-53(Al), and UiO-66(Zr)) by examining molecular interactions and calculating free binding energies. Subsequently, the four water-stable MOFs were synthesized and evaluated as adsorbents for the target hormones in aqueous solution. As the MOF exhibiting the highest adsorption capacity in both computations and experiments, MIL-53(Al) was chosen as a sorbent to develop a dispersive micro-solid-phase extraction procedure coupled to ultra-performance liquid chromatography tandem mass spectrometry for simultaneous determination of the target analytes in water and human urine samples. Experimental parameters affecting the extraction recoveries, including pH, ionic strength, MIL-53(Al) amount, extraction time, desorption time, and desorption solvent, were optimized. The optimized method provided a linear range of 0.005025-368.6μg/L with good correlation coefficients (0.9982 ≤ r 2 ≤ 0.9992), and limits of detection (S/N = 3) and quantification (S/N = 10) of 0.0015-1.0μg/L and 0.005-1.8μg/L, respectively. The analyte recoveries were in the range of 80.6-98.4% in water samples and 88.4-93.2% in urine samples. Furthermore, MIL-53(Al) showed good stability over 10 extraction cycles (RSD < 10.0%). Good agreement between experimental measurements and computational results showed the potential of this approach for elucidating adsorption mechanisms and predicating extraction efficiencies for MOFs and targets, providing new directions for the development and utilization of MOFs. Copyright © 2017 Elsevier B.V. All rights reserved.
Anilanmert, Beril; Çavuş, Fatma; Narin, Ibrahim; Cengiz, Salih; Sertler, Şefika; Özdemir, Ali Acar; Açikkol, Münevver
2016-06-01
Date-rape drugs have the potential to be used in drug-facilitated sexual assault, organ theft and property theft. Since they are colorless, tasteless and odorless, victims can drink without noticing, when added to the beverages. These drugs must be detected in time, before they are cleared up from the biofluids. A simultaneous extraction and determination method in urine for GHB, ketamine, norketamine, phenobarbital, thiopental, zolpidem, zopiclone and phenytoin (an anticonvulsant and antiepileptic drug) with LC-MS/MS was developed for the first time with analytically acceptable recoveries and validated. A 4 steps liquid-liquid extraction was applied, using only 1.000mL urine. A new age commercial C18 poroshell column with high column efficiency was used for LC-MS/MS analysis with a fast isocratic elution as 5.5min. A new MS transition were introduced for barbital. 222.7>179.8 with the effect of acetonitrile. Recoveries (%) were between 80.98-99.27 for all analytes, except for GHB which was 71.46. LOD and LOQ values were found in the ranges of 0.59-49.50 and 9.20-80.80ngmL(-1) for all the analytes (except for GHB:3.44 and 6.00μgmL(-1)). HorRat values calculated (between 0.25-1.21), revealed that the inter-day and interanalist precisions (RSD%≤14.54%) acceptable. The simultaneous extraction and determination of these 8 analytes in urine is challenging because of the difficulty arising from the different chemical properties of some. Since the procedure can extract drugs from a wide range of polarity and pKa, it increases the window of detection. Group representatives from barbiturates, z-drugs, ketamine, phenytoin and polar acidic drugs (GHB) have been successfully analyzed in this study with low detection limits. The method is important from the point of determining the combined or single use of these drugs in crimes and finding out the reasons of deaths related to these drugs. Copyright © 2016 Elsevier B.V. All rights reserved.
Johner, S A; Boeing, H; Thamm, M; Remer, T
2015-12-01
The assessment of urinary excretion of specific nutrients (e.g. iodine, sodium) is frequently used to monitor a population's nutrient status. However, when only spot urines are available, always a risk of hydration-status-dependent dilution effects and related misinterpretations exists. The aim of the present study was to establish mean values of 24-h creatinine excretion widely applicable for an appropriate estimation of 24-h excretion rates of analytes from spot urines in adults. Twenty-four-hour creatinine excretion from the formerly representative cross-sectional German VERA Study (n=1463, 20-79 years old) was analysed. Linear regression analysis was performed to identify the most important influencing factors of creatinine excretion. In a subsample of the German DONALD Study (n=176, 20-29 years old), the applicability of the 24-h creatinine excretion values of VERA for the estimation of 24-h sodium and iodine excretion from urinary concentration measurements was tested. In the VERA Study, mean 24-h creatinine excretion was 15.4 mmol per day in men and 11.1 mmol per day in women, significantly dependent on sex, age, body weight and body mass index. Based on the established 24-h creatinine excretion values, mean 24-h iodine and sodium excretions could be estimated from respective analyte/creatinine concentrations, with average deviations <10% compared with the actual 24-h means. The present mean values of 24-h creatinine excretion are suggested as a useful tool to derive realistic hydration-status-independent average 24-h excretion rates from urinary analyte/creatinine ratios. We propose to apply these creatinine reference means routinely in biomarker-based studies aiming at characterizing the nutrient or metabolite status of adult populations by simply measuring metabolite/creatinine ratios in spot urines.
Muto, Satoru; Sugiura, Syo-Ichiro; Nakajima, Akiko; Horiuchi, Akira; Inoue, Masahiro; Saito, Keisuke; Isotani, Shuji; Yamaguchi, Raizo; Ide, Hisamitsu; Horie, Shigeo
2014-10-01
We aimed to identify patients with a chief complaint of hematuria who could safely avoid unnecessary radiation and instrumentation in the diagnosis of bladder cancer (BC), using automated urine flow cytometry to detect isomorphic red blood cells (RBCs) in urine. We acquired urine samples from 134 patients over the age of 35 years with a chief complaint of hematuria and a positive urine occult blood test or microhematuria. The data were analyzed using the UF-1000i (®) (Sysmex Co., Ltd., Kobe, Japan) automated urine flow cytometer to determine RBC morphology, which was classified as isomorphic or dysmorphic. The patients were divided into two groups (BC versus non-BC) for statistical analysis. Multivariate logistic regression analysis was used to determine the predictive value of flow cytometry versus urine cytology, the bladder tumor antigen test, occult blood in urine test, and microhematuria test. BC was confirmed in 26 of 134 patients (19.4 %). The area under the curve for RBC count using the automated urine flow cytometer was 0.94, representing the highest reference value obtained in this study. Isomorphic RBCs were detected in all patients in the BC group. On multivariate logistic regression analysis, only isomorphic RBC morphology was significantly predictive for BC (p < 0.001). Analytical parameters such as sensitivity, specificity, positive predictive value, and negative predictive value of isomorphic RBCs in urine were 100.0, 91.7, 74.3, and 100.0 %, respectively. Detection of urinary isomorphic RBCs using automated urine flow cytometry is a reliable method in the diagnosis of BC with hematuria.
Huang, Bin; Zhang, Lei; Zhang, Weizheng; Liao, Kang; Zhang, Shihong; Zhang, Zhiquan; Ma, Xingyan; Chen, Jialong; Zhang, Xiuhong; Qu, Pinghua; Wu, Shangwei
2017-01-01
ABSTRACT Rapid and accurate detection and identification of microbial pathogens causing urinary tract infections allow prompt and specific treatment. We optimized specimen processing to maximize the limit of detection (LOD) by matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) and evaluated the capacity of combination of MALDI-TOF MS and urine analysis (UA) for direct detection and identification of bacterial pathogens from urine samples. The optimal volumes of processed urine, formic acid/acetonitrile, and supernatant spotted onto the target plate were 15 ml, 3 μl, and 3 μl, respectively, yielding a LOD of 1.0 × 105 CFU/ml. Among a total of 1,167 urine specimens collected from three hospital centers, 612 (52.4%) and 351 (30.1%) were, respectively, positive by UA and urine culture. Compared with a reference method comprised of urine culture and 16S rRNA gene sequencing, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MALDI-TOF MS alone and MALDI-TOF MS coupled with UA were 86.6% versus 93.4% (χ2 = 8.93; P < 0.01), 91.5% versus 96.3% (χ2 = 7.06; P < 0.01), 81.5% versus 96.4% (χ2 = 37.32; P < 0.01), and 94.1% versus 93.1% (χ2 = 0.40; P > 0.05), respectively. No significant performance differences were revealed among the three sites, while specificity and NPV of MALDI-TOF MS for males were significantly higher than those for females (specificity, 94.3% versus 77.3%, χ2 = 44.90, P < 0.01; NPV, 95.5% versus 86.1%, χ2 = 18.85, P < 0.01). Our results indicated that the optimization of specimen processing significantly enhanced analytical sensitivity and that the combination of UA and MALDI-TOF MS provided an accurate and rapid detection and identification of bacterial pathogens directly from urine. PMID:28249997
Huang, Bin; Zhang, Lei; Zhang, Weizheng; Liao, Kang; Zhang, Shihong; Zhang, Zhiquan; Ma, Xingyan; Chen, Jialong; Zhang, Xiuhong; Qu, Pinghua; Wu, Shangwei; Chen, Cha; Tang, Yi-Wei
2017-05-01
Rapid and accurate detection and identification of microbial pathogens causing urinary tract infections allow prompt and specific treatment. We optimized specimen processing to maximize the limit of detection (LOD) by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and evaluated the capacity of combination of MALDI-TOF MS and urine analysis (UA) for direct detection and identification of bacterial pathogens from urine samples. The optimal volumes of processed urine, formic acid/acetonitrile, and supernatant spotted onto the target plate were 15 ml, 3 μl, and 3 μl, respectively, yielding a LOD of 1.0 × 10 5 CFU/ml. Among a total of 1,167 urine specimens collected from three hospital centers, 612 (52.4%) and 351 (30.1%) were, respectively, positive by UA and urine culture. Compared with a reference method comprised of urine culture and 16S rRNA gene sequencing, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MALDI-TOF MS alone and MALDI-TOF MS coupled with UA were 86.6% versus 93.4% (χ 2 = 8.93; P < 0.01), 91.5% versus 96.3% (χ 2 = 7.06; P < 0.01), 81.5% versus 96.4% (χ 2 = 37.32; P < 0.01), and 94.1% versus 93.1% (χ 2 = 0.40; P > 0.05), respectively. No significant performance differences were revealed among the three sites, while specificity and NPV of MALDI-TOF MS for males were significantly higher than those for females (specificity, 94.3% versus 77.3%, χ 2 = 44.90, P < 0.01; NPV, 95.5% versus 86.1%, χ 2 = 18.85, P < 0.01). Our results indicated that the optimization of specimen processing significantly enhanced analytical sensitivity and that the combination of UA and MALDI-TOF MS provided an accurate and rapid detection and identification of bacterial pathogens directly from urine. Copyright © 2017 American Society for Microbiology.
Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine
2013-01-01
Introduction. Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining 1H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. Methods. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after 1H NMR spectroscopy. Results. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at −20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Conclusion. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions. PMID:23865070
Peptidomics of urine and other biofluids for cancer diagnostics.
Bauça, Josep Miquel; Martínez-Morillo, Eduardo; Diamandis, Eleftherios P
2014-08-01
Cancer is a leading cause of death worldwide. The low diagnostic sensitivity and specificity of most current cancer biomarkers make early cancer diagnosis a challenging task. The comprehensive study of peptides and small proteins in a living system, known as "peptidomics," represents an alternative technological approach to the discovery of potential biomarkers for the assessment of a wide variety of pathologies. This review examines the current status of peptidomics for several body fluids, with a focus on urine, for cancer diagnostics applications. Several studies have used high-throughput technologies to characterize the peptide content of different body fluids. Because of its noninvasive collection and high stability, urine is a valuable source of candidate cancer biomarkers. A wide variety of preanalytical issues concerning patient selection and sample handling need to be considered, because not doing so can affect the quality of the results by introducing bias and artifacts. Optimization of both the analytical strategies and the processing of bioinformatics data is also essential to minimize the false-discovery rate. Peptidomics-based studies of urine and other body fluids have yielded a number of biomolecules and peptide panels with potential for diagnosing different types of cancer, especially of the ovary, prostate, and bladder. Large-scale studies are needed to validate these molecules as cancer biomarkers. © 2013 American Association for Clinical Chemistry.
Aarsand, Aasne K; Villanger, Jørild H; Støle, Egil; Deybach, Jean-Charles; Marsden, Joanne; To-Figueras, Jordi; Badminton, Mike; Elder, George H; Sandberg, Sverre
2011-11-01
The porphyrias are a group of rare metabolic disorders whose diagnosis depends on identification of specific patterns of porphyrin precursor and porphyrin accumulation in urine, blood, and feces. Diagnostic tests for porphyria are performed by specialized laboratories in many countries. Data regarding the analytical and diagnostic performance of these laboratories are scarce. We distributed 5 sets of multispecimen samples from different porphyria patients accompanied by clinical case histories to 18-21 European specialist porphyria laboratories/centers as part of a European Porphyria Network organized external analytical and postanalytical quality assessment (EQA) program. The laboratories stated which analyses they would normally have performed given the case histories and reported results of all porphyria-related analyses available, interpretative comments, and diagnoses. Reported diagnostic strategies initially showed considerable diversity, but the number of laboratories applying adequate diagnostic strategies increased during the study period. We found an average interlaboratory CV of 50% (range 12%-152%) for analytes in absolute concentrations. Result normalization by forming ratios to the upper reference limits did not reduce this variation. Sixty-five percent of reported results were within biological variation-based analytical quality specifications. Clinical interpretation of the obtained analytical results was accurate, and most laboratories established the correct diagnosis in all distributions. Based on a case-based EQA scheme, variations were apparent in analytical and diagnostic performance between European specialist porphyria laboratories. Our findings reinforce the use of EQA schemes as an essential tool to assess both analytical and diagnostic processes and thereby to improve patient care in rare diseases.
Block, Darci R; Algeciras-Schimnich, Alicia
2013-01-01
Requests for testing various analytes in serous fluids (e.g., pleural, peritoneal, pericardial effusions) are submitted daily to clinical laboratories. Testing of these fluids deviates from assay manufacturers' specifications, as most laboratory assays are optimized for testing blood or urine specimens. These requests add a burden to clinical laboratories, which need to validate assay performance characteristics in these fluids to exclude matrix interferences (given the different composition of body fluids) while maintaining regulatory compliance. Body fluid testing for a number of analytes has been reported in the literature; however, understanding the clinical utility of these analytes is critical because laboratories must address the analytic and clinical validation requirements, while educating clinicians on proper test utilization. In this article, we review the published data to evaluate the clinical utility of testing for numerous analytes in body fluid specimens. We also highlight the pre-analytic and analytic variables that need to be considered when reviewing published studies in body fluid testing. Finally, we provide guidance on how published studies might (or might not) guide interpretation of test results in today's clinical laboratories.
Thevis, Mario; Geyer, Hans; Thomas, Andreas; Tretzel, Laura; Bailloux, Isabelle; Buisson, Corinne; Lasne, Francoise; Schaefer, Maximilian S; Kienbaum, Peter; Mueller-Stoever, Irmela; Schänzer, Wilhelm
2015-11-10
Chlorazanil (Ordipan, N-(4-chlorophenyl)-1,3,5-triazine-2,4-diamine) is a diuretic agent and as such prohibited in sport according to the regulations of the World Anti-Doping Agency (WADA). Despite its introduction into clinical practice in the late 1950s, the worldwide very first two adverse analytical findings were registered only in 2014, being motive for an in-depth investigation of these cases. Both individuals denied the intake of the drug; however, the athletes did declare the use of the antimalarial prophylactic agent proguanil due to temporary residences in African countries. A structural similarity between chlorazanil and proguanil is given but no direct metabolic relation has been reported in the scientific literature. Moreover, chlorazanil has not been confirmed as a drug impurity of proguanil. Proguanil however is metabolized in humans to N-(4-chlorophenyl)-biguanide, which represents a chemical precursor in the synthesis of chlorazanil. In the presence of formic acid, formaldehyde, or formic acid esters, N-(4-chlorophenyl)-biguanide converts to chlorazanil. In order to probe for potential sources of the chlorazanil detected in the doping control samples, drug formulations containing proguanil and urine samples of individuals using proguanil as antimalarial drug were subjected to liquid chromatography-high resolution/high accuracy mass spectrometry. In addition, in vitro simulations with 4-chlorophenyl-biguanide and respective reactants were conducted in urine and resulting specimens analyzed for the presence of chlorazanil. While no chlorazanil was found in drug formulations, the urine samples of 2 out of 4 proguanil users returned findings for chlorazanil at low ng/mL levels, similar to the adverse analytical findings in the doping control samples. Further, in the presence of formaldehyde, formic acid and related esters, 4-chlorophenyl-biguanide was found to produce chlorazanil in human urine, suggesting that the detection of the obsolete diuretic agent was indeed the result of artefact formation and not of the illicit use of a prohibited substance. Copyright © 2015 Elsevier B.V. All rights reserved.
Bhandari, Deepak; Bowman, Brett A; Patel, Anish B; Chambers, David M; De Jesús, Víctor R; Blount, Benjamin C
2018-04-15
This work describes a quantitative high-throughput analytical method for the simultaneous measurement of small aliphatic nitrogenous biomarkers, i.e., 1,6-hexamethylenediamine (HDA), isophoronediamine (IPDA), β-methylamino-l-alanine (BMAA), and trimethylamine N-oxide (TMAO), in human urine. Urinary aliphatic diamines, HDA and IPDA, are potential biomarkers of environmental exposure to their corresponding diisocyanates. Urinary BMAA forms as a result of human exposure to blue-green algae contaminated food. And, TMAO is excreted in urine due to the consumption of carnitine- and choline-rich diets. These urinary biomarkers represent classes of small aliphatic nitrogen-containing compounds (N-compounds) that have a high aqueous solubility, low logP, and/or high basic pK a . Because of the highly polar characteristics, analysis of these compounds in complex sample matrices is often challenging. We report on the development of ion-pairing chemistry based ultra-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) method for the simultaneous measurement of these biomarkers in human urine. Chromatographic separation was optimized using heptafluorobutyric acid-(HFBA-) based mobile phase and a reversed-phase C18 column. All four analytes were baseline separated within 2.6 min with an overall run time of 5 min per sample injection. Sample preparation involved 4 h of acid hydrolysis followed by automated solid phase extraction (SPE) performed using strong cation exchange sorbent bed with 7 N ammonia solution in methanol as eluent. Limits of detection ranged from 0.05 ng/mL to 1.60 ng/mL. The inter-day and intra-day accuracy were within 10%, and reproducibility within 15%. The method is accurate, fast, and well-suited for biomonitoring studies within targeted groups, as well as larger population-based studies such as the U. S. National Health and Nutrition Examination Survey (NHANES). Published by Elsevier B.V.
Kumar, Ashwini; Kumar Malik, Ashok; Kumar Tewary, Dhananjay; Singh, Baldev
2008-02-01
A simple and highly sensitive high pressure liquid chromatographic (HPLC-UV) method has been developed for the determination of ofloxacin, lomefloxacin, cinoxacin, and nalidixic acid, in mobile phase citrate buffer (0.001 M) of pH 4.5 prepared in water (X), methanol (Y), and ACN (Z) using gradient at a flow rate of 1.0 mL/min by direct UV absorbance detection at lambda = 280 nm. Separation of analytes was studied on the C-18 and RP-amide columns and best results were observed on the RP-amide column with LODs (3.3 x S/m) 0.89, 0.55, 0.67, and 1.41 ng/mL for ofloxacin, lomefloxacin, cinoxacin, and nalidixic acid, respectively, and better RSD than the C-18 column. The recovery of Fluoroquinolones (FQs) in urine, ground water, hospital wastewater, and chicken muscle using this method is more than 90%. The method was successfully applied to the analysis of ofloxacin, lomefloxacin, cinoxacin, and nalidixic acid in urine, ground water, pharmaceutical dosage forms, hospital wastewater, and chicken muscle.
Xiong, Bo; Wang, Ling-Ling; Li, Qiong; Nie, Yu-Ting; Cheng, Shuang-Shuang; Zhang, Hui; Sun, Ren-Qiang; Wang, Yu-Jiao; Zhou, Hong-Bin
2015-11-01
A parallel microscope-based laser-induced fluorescence (LIF), ultraviolet-visible absorbance (UV) and time-of-flight mass spectrometry (TOF-MS) detection for high performance liquid chromatography (HPLC) was achieved and used to determine glucosamine in urines. First, a reliable and convenient LIF detection was developed based on an inverted microscope and corresponding modulations. Parallel HPLC-LIF/UV/TOF-MS detection was developed by the combination of preceding Microscope-based LIF detection and HPLC coupled with UV and TOF-MS. The proposed setup, due to its parallel scheme, was free of the influence from photo bleaching in LIF detection. Rhodamine B, glutamic acid and glucosamine have been determined to evaluate its performance. Moreover, the proposed strategy was used to determine the glucosamine in urines, and subsequent results suggested that glucosamine, which was widely used in the prevention of the bone arthritis, was metabolized to urines within 4h. Furthermore, its concentration in urines decreased to 5.4mM at 12h. Efficient glucosamine detection was achieved based on a sensitive quantification (LIF), a universal detection (UV) and structural characterizations (TOF-MS). This application indicated that the proposed strategy was sensitive, universal and versatile, and it was capable of improved analysis, especially for analytes with low concentrations in complex samples, compared with conventional HPLC-UV/TOF-MS. Copyright © 2015 Elsevier B.V. All rights reserved.
Preanalytical requirements of urinalysis
Delanghe, Joris; Speeckaert, Marijn
2014-01-01
Urine may be a waste product, but it contains an enormous amount of information. Well-standardized procedures for collection, transport, sample preparation and analysis should become the basis of an effective diagnostic strategy for urinalysis. As reproducibility of urinalysis has been greatly improved due to recent technological progress, preanalytical requirements of urinalysis have gained importance and have become stricter. Since the patients themselves often sample urine specimens, urinalysis is very susceptible to preanalytical issues. Various sampling methods and inappropriate specimen transport can cause important preanalytical errors. The use of preservatives may be helpful for particular analytes. Unfortunately, a universal preservative that allows a complete urinalysis does not (yet) exist. The preanalytical aspects are also of major importance for newer applications (e.g. metabolomics). The present review deals with the current preanalytical problems and requirements for the most common urinary analytes. PMID:24627718
Gao, Li; Wei, Yinmao
2016-06-01
Various cotton fiber based boronate-affinity adsorbents are recently developed for the sample pretreatment of cis-diol-containing biomolecules, but most do not have efficient capacity due to limited binding sites on the surface of cotton fibers. To increase the density of boronate groups on the surface of cotton fiber, polyhedral oligomeric silsesquioxanes were used to modify cotton fiber to provide plentiful reactive sites for subsequent functionalization with 4-formylphenylboronic acid. The new adsorbent showed special recognition ability towards cis-diols and high adsorption capacity (175 μg/g for catechol, 250 μg/g for dopamine, 400 μg/g for adenosine). The in-pipette-tip solid-phase extraction was investigated under different conditions, including pH and ionic strength of solution, adsorbent amount, pipette times, washing solvent, and elution solvent. The in-pipette-tip solid-phase extraction coupled with high-performance liquid chromatography was used to analyze four nucleosides in urine samples. Under the optimal extraction conditions, the detection limits were determined to be between 5.1 and 6.1 ng/mL (S/N = 3), and the linearity ranged from 20 to 500 ng/mL for these analytes. The accuracy of the analytical method was examined by studying the relative recoveries of analytes in real urine samples with recoveries varying from 83 to 104% (RSD = 3.9-10.2%, n = 3). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fan, Ruifang; Ramage, Robert; Wang, Dongli; Zhou, Junqiang; She, Jianwen
2012-05-15
The aim of this study is to develop and validate an analytical method for the quantitation of ten urinary monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) through high pressure liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). After enzymatic deconjugation, urine samples were extracted by liquid-liquid extraction (LLE) and OH-PAHs were analyzed by HPLC/MS/MS operated in negative electrospray ionization (ESI) and multiple reaction monitoring (MRM) mode. LLE was conducted with the solvent mixture of pentane and toluene, which reduced the matrix interferences and enhanced the method sensitivity significantly. Deuterated and (13)C-labeled analogs are used as internal standards. Calibration curves of all target analytes shows favorable linearity within the concentration range of 5.9-15,000.0 ng/L for different OH-PAHs with the regression coefficients above 0.993. The limits of detection (LODs) in pooled urine ranged from 1.72 to 17.47 ng/L, which were much lower than those obtained by a gas chromatography/high resolution mass spectrometry (GC/HRMS) method. The method shows satisfactory accuracy and precision when analyzing three different levels of OH-PAHs spiked in pooled urine. Except for 1-hydroxynaphthalene, recoveries of other OH-PAHs were in the range of 100 ± 20% with a variation coefficient of less than 13%. The measurement of OH-PAHs from a QC sample of the Centers for Disease Control and Prevention (CDC) generated results close to the values measured by CDC. This method has been successfully employed in the California Biomonitoring Program. Published by Elsevier B.V.
Kakimoto, Kensaku; Toriba, Akira; Ohno, Takanori; Ueno, Mariko; Kameda, Takayuki; Tang, Ning; Hayakawa, Kazuichi
2008-05-15
To evaluate human exposure to polycyclic aromatic hydrocarbons (PAHs), we developed a rapid, simple and sensitive method for determining 1-hydroxypyrene-glucuronide (1-OHP-G) in human urine. To improve precision, a deuterated glucuronide was used as an internal standard. The method requires only 1 mL of urine. The urine was treated with a mixed-mode anion-exchange and reversed-phase solid-phase extraction cartridge (Oasis MAX). The analytes were analyzed with a C(18) reversed-phase column with a gradient elution, followed by tandem mass spectrometry with electrospray ionization in negative ion mode. The detection limit of 1-OHP-G (corresponding to a signal-to-noise ratio of 3) was 0.13 fmol/injection. Urinary concentrations of 1-OHP-G determined by this method were strongly correlated (r(2)=0.961) with concentrations of 1-hydroxypyrene by conventional HPLC with fluorescence detection.
Lu, Huihui; Conneely, Gráinne; Pravda, Miloslav; Guilbault, George G
2006-09-01
Electrochemical based immunosensors for the detection of boldenone and methylboldenone in bovine urine were described in this paper. The immunosensors were fabricated by immobilizing boldenone-bovine serum albumin conjugate on the surface of screen-printed electrodes (SPEs), and followed by the competition between the free analyte and coating conjugate with corresponding antibodies. The use of anti-species IgG-horseradish peroxidase conjugate determined the degree of competition. The electrochemical technique chosen was chronoamperometry, performed at a potential of +100 mV whereby the product of the catalysis of 3,3',5,5'-tetramethylbenzidine undergoes reduction produced by the enzyme label. The limits of detection of assay were 30.9+/-4.3 pg ml(-1) for boldenone and 120.2+/-8.2 pg ml(-1) for methylboldenone, respectively. Results of repeated analysis of each androgen carried out using three different batches of electrodes indicate suitable repeatability (EC(50)=1.0+/-0.3 ng ml(-1)(n=3, N=3), R(2)=0.969, R.S.D.=9.6% for boldenone and 1.5+/-0.3 ng ml(-1), 0.971, 10.5% for methylboldenone, respectively). Urine samples were determined directly after a single dilution step, omitting extraction and hydrolysis. This method offers the advantage to pick up both boldenone and its major metabolites in an efficient manner due to the high cross-reactivity pattern of alpha-boldenone with this antibody. The concentration of methylboldenone in urine detected by developed methods does indicate methylboldenone administration to heifers. Gas chromatography coupled to mass spectrometry analysis was performed to quantitate the individual metabolites present in urine samples, and results were validated with both ELISA and immunosensor data.
Grace, Philip B; Drake, Erica C; Teale, Philip; Houghton, Edward
2008-10-01
Following administration of the anabolic steroid 19-nortestosterone or its esters to the horse, a major urinary metabolite is 19-nortestosterone-17beta-sulphate. The detection of 19-nortestosterone in urine from untreated animals has led to it being considered a naturally occurring steroid in the male horse. Recently, we have demonstrated that the majority of the 19-nortestosterone found in extracts of 'normal' urine from male horses arises as an artefact through decarboxylation of the 19-carboxylic acid of testosterone. The aim of this investigation was to establish if direct analysis of 19-nortestosterone-17beta-sulphate by liquid chromatography/tandem mass spectrometry (LC/MS/MS) had potential for the detection of 19-nortestosterone misuse in the male horse. The high concentrations of sulphate conjugates of the female sex hormones naturally present in male equine urine were overcome by selective hydrolysis of the aryl sulphates using glucuronidase from Helix pomatia; this was shown to have little or no activity for alkyl sulphates such as 19-nortestosterone-17beta-sulphate. The 'free' phenolic steroids were removed by solid-phase extraction (SPE) prior to LC/MS/MS analysis. The method also allowed for the quantification of the sulphate conjugate of boldenone, a further anabolic steroid endogenous in the male equine with potential for abuse in sports. The method was applied to the quantification of these analytes in a population of samples. This paper reports the results of that study along with the development and validation of the LC/MS/MS method. The results indicate that while 19-nortestosterone-17beta-sulphate is present at low levels as an endogenous substance in urine from 'normal' male horses, its use as an effective threshold substance may be viable.
Environmental heat stress enhances crystallization in urine
NASA Astrophysics Data System (ADS)
Setyawan, H.; Pratiwi, Q. C.; Sjarifah, I.; Atmojo, T. B.; Khotijah
2018-03-01
Over the past several decades, agriculture and plantations have been used as the main livelihood of most of the Karanganyar residents. However, these two sources of living are now replaced by industrial areas that employ thousands of people in that district. The development of this industry triggers multiple environmental impacts, including ecosystem and temperature changes. In consequence, there is an increase in air temperature that can cause a variety of diseases, especially in the workplace. According to the International Labour Organization (ILO) data in 2013, one worker dies every 15 second due to a work accident and 160 workers are suffering from the occupational disease. In Indonesia, the incidence of crystallization in urine is actually still unknown, but it is estimated that there are 170,000 cases annually. A high temperature or called heat stress is one among many factors causing this disease to appear. The workers in the textile industry, especially in the Finishing Department Kusumahadi Co. Ltd that exposed heat stress from the finishing machines and inadequate ventilation. This hot working climate causes the human body to adapt in the form of body cooling mechanism or called sweating This adaptation can cause an increase in sweat production and decrease the production of urine. If it is not followed by consuming the recommended amount of water intake, it can result in the precipitation of body salts that, in a long time, will cause crystallization in urine. The research used the analytic observational designs for a cross-sectional study. There were 34 samples collected from 57 finishing workers. The data were analyzed using Spearman correlation test. The results showed that heat stress (p=0,015) and water intake (p=0,034) has a significant correlation with crystallization in urine.
Quantitative determination of mycotoxins in urine by LC-MS/MS.
Ahn, J; Kim, D; Kim, H; Jahng, K-Y
2010-12-01
Naturally occurring mycotoxins are responsible for a wide array of adverse health effects. The measurement of urinary mycotoxin levels is a useful means of assessing an individual's exposure, but the development of sensitive and accurate analytical methods for detecting mycotoxins and their metabolites in urine samples is challenging. Urinary mycotoxins are present in low pg ml⁻¹ concentrations, and the chromatographic identification of their metabolites can be obscured by other endogenous metabolites. We developed an analytical method focused on the selection of two appropriate multiple-reaction monitoring transition for unambiguous identification and quantification of carcinogenic aflatoxin M₁ (AFM₁), ochratoxin A (OTA) and fumonisin B₁, B₂ (FB₁, FB₂) in urine samples from a small volunteer group in a pilot study. AFM₁, OTA, FB₁ and FB₂ were concentrated selectively, interfering substances were removed using an immunoaffinity column (IAC), and mycotoxins were measured using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in combination with a stable-isotope standard-dilution assay (SIDA). The method was sensitive enough to measure mycotoxins and their metabolites at pg ml⁻¹ levels in urine. The combination of LC-MS/MS and SIDA was critical to distinguishing pseudo-OTα interference from genuine OTα. Twelve urine samples contained OTA ranging from 0.013 to 0.093 ng ml⁻¹ (mean = 0.031 ng ml⁻¹). AFM₁ were detected in one sample at a 0.002 ng ml⁻¹ level, while FB₁ and FB₂ were undetectable in all 12 samples. None of the samples in this pilot study contained a detectable level of OTα, despite the presence of OTA, and this may suggest the need for further epidemiological investigation of OTA exposure in the Korean population.
Dumasia, M C; Teale, P
2005-01-04
Millophyline-V, (etamiphylline camsylate) was administered intramuscularly to two racing greyhounds at a dose of 10 mg kg(-1). Unhydrolysed pre- and post-administration urine samples were extracted using mixed mode solid phase extraction (SPE) cartridges, the basic isolates derivatised as trimethylsilyl ethers and analysed by positive ion electron ionisation gas chromatography-mass spectrometry (GC/EI+/MS). The parent drug and one metabolite, N-desethyletamiphylline, were detected in urine for up to 72 h. For semi-quantification, urine samples were extracted on-line using a Prospekt sample handler. The analytes retained on the C2 SPE cartridge were eluted by the mobile phase directly on to the analytical high performance liquid chromatography column and analysed by positive ion atmospheric pressure chemical ionisation (LC/APCI+) MS in the multiple selective-ion recording mode. A major peak containing both ions (m/z) 280 and (m/z) 252 was observed. Full scan LC/APCI+/MS of the unknown indicated that the ion at (m/z) 280 was formed by the loss of an oxygen atom [MH+ -->(MH+-O)]. Samples were analysed by positive ion electrospray ionisation LC/MS on two different instruments and the unknown compound was identified as an N-oxide of the tert. nitrogen atom of the 2-(diethylamino)ethyl substituent on N7 of the theophylline nucleus. This compound has not been reported previously either as an in vivo or in vitro metabolite of etamiphylline in any species. Thermal decomposition of the N-oxide could lead to an increase the detection period of the parent drug during routine GC/MS screening of post-competition greyhound urine samples.
Magiera, Sylwia; Gülmez, Şefika; Michalik, Aleksandra; Baranowska, Irena
2013-08-23
A new approach based on microextraction by packed sorbent (MEPS) and a reversed-phase ultra-high pressure liquid chromatography (UHPLC) method was developed and validated for the determination and quantification of nonsteroidal anti-inflammatory drugs (NSAIDs) (acetylsalicylic acid, ketoprofen, diclofenac, naproxen and ibuprofen) in human urine. The important factors that could influence the extraction were previously screened using the Plackett-Burman design approach. The optimal MEPS extraction conditions were obtained using C18 phase as a sorbent, small sample volume (20μL) and a short time period (approximately 5min) for the entire sample preparation step. The analytes were separated on a core-shell column (Poroshell 120 EC-C18; 100mm×3.0mm; 2.7μm) using a binary mobile phase composed of aqueous 0.1% trifluoroacetic acid and acetonitrile in the gradient elution mode (4.5min of analysis time). The analytical method was fully validated based on linearity, limits of detection (LOD), limits of quantification (LOQ), inter- and intra-day precision and accuracy, and extraction yield. Under optimised conditions, excellent linearity (R(2)>0.9991), limits of detection (1.07-16.2ngmL(-1)) and precision (0.503-9.15% RSD) were observed for the target drugs. The average absolute recoveries of the analysed compounds extracted from the urine samples were 89.4-107%. The proposed method was also applied to the analysis of NSAIDs in human urine. The new approach offers an attractive alternative for the analysis of selected drugs from urine samples, providing several advantages including fewer sample preparation steps, faster sample throughput and ease of performance compared to traditional methodologies. Copyright © 2013 Elsevier B.V. All rights reserved.
Dickinson, John; Hu, Jie; Chester, Neil; Loosemore, Mike; Whyte, Greg
2014-11-01
To examine the impact of dehydration, ethnicity, and gender on urinary concentrations of salbutamol in relation to the threshold stipulated by the World Anti-Doping Agency (WADA). Repeated measures open-label. Eighteen male and 14 female athletes (9 white males, 9 white females, 2 Afro-Caribbean males, 2 Afro-Caribbean females, 6 Asian [Indian subcontinent] males, and 4 Asian females) were recruited. All participants were nonasthmatic. After inhalation of 800 μg or 1600 μg of salbutamol, athletes exercised in a hot controlled environment (35°C, 40% relative humidity) at a self-selected pace until a target weight loss (2% or 5%) was achieved. Urine concentration of free salbutamol. After inhalation of 1600 μg salbutamol, 20 participants presented with a urine salbutamol concentrations above the current WADA limit (1000 ng/mL) and decision limit (1200 ng/mL) resulting in an adverse analytical finding. There were no differences according to gender or ethnic origin. Dehydration equivalent to a body mass loss greater than 2% concomitant to the acute inhalation of 1600 μg of salbutamol may result in a urine concentration above the current WADA limit and decision limit leading to a positive test finding independent of gender or ethnic origin. Asthmatic athletes using salbutamol should receive clear dosing advise and education to minimize the risk of inhaling doses of salbutamol that may produce urine concentrations of salbutamol above 1200 ng/mL.
Molecular correlates in urine for the obesity and prostatic inflammation of BPH/LUTS patients.
Tyagi, Pradeep; Motley, Saundra S; Koyama, Tatsuki; Kashyap, Mahendra; Gingrich, Jeffrey; Yoshimura, Naoki; Fowke, Jay H
2018-01-01
Benign prostatic hyperplasia (BPH) is strongly associated with obesity and prostatic tissue inflammation, but the molecular underpinning of this relationship is not known. Here, we examined the association between urine levels of chemokines/adipokines with histological markers of prostate inflammation, obesity, and lower urinary tract symptoms LUTS in BPH patients. Frozen urine specimens from 207 BPH/LUTS patients enrolled in Nashville Men's Health Study were sent for blinded analysis of 11 analytes, namely sIL-1RA, CXC chemokines (CXCL-1, CXCL-8, CXCL-10), CC chemokines (CCL2, CCL3, CCL5), PDGF-BB, interleukins IL-6, IL-17, and sCD40L using Luminex™ xMAP® technology. After adjusting for age and medication use, the urine levels of analytes were correlated with the scales of obesity, prostate inflammation grade, extent, and markers of lymphocytic infiltration (CD3 and CD20) using linear regression. sIL-1RA levels were significantly raised with higher BMI, waist circumference and waist-hip ratio in BPH patients after correction for multiple testing (P = 0.02). Men with greater overall extent of inflammatory infiltrates and maximal CD3 infiltration were marginally associated with CXCL-10 (P = 0.054) and CCL5 (P = 0.054), respectively. CCL3 in 15 patients with moderate to severe grade inflammation was marginally associated with maximal CD20 infiltration (P = 0.09), whereas CCL3 was undetectable in men with mild prostate tissue inflammation. There was marginal association of sCD40L with AUA-SI scores (P = 0.07). Strong association of sIL-1RA in urine with greater body size supports it as a major molecular correlate of obesity in the urine of BPH patients. Increased urine levels of CXCL-10, CCL5, and CCL3 were marginally associated with the scores for prostate tissue inflammation and lymphocytic infiltration. Overall, elevated urinary chemokines support that BPH is a metabolic disorder and suggest a molecular link between BPH/LUTS and prostatic inflammation. © 2017 Wiley Periodicals, Inc.
Anti-doping analyses at the Sochi Olympic and Paralympic Games 2014.
Sobolevsky, Tim; Krotov, Grigory; Dikunets, Marina; Nikitina, Maria; Mochalova, Elena; Rodchenkov, Grigory
2014-01-01
The laboratory anti-doping services during XXII Winter Olympic and XI Paralympic games in Sochi in 2014 were provided by a satellite laboratory facility located within the strictly secured Olympic Park. This laboratory, established and operated by the personnel of Antidoping Center, Moscow, has been authorized by the World Anti-Doping Agency (WADA) to conduct doping control analyses. The 4-floor building accommodated the most advanced analytical instrumentation and became a place of attraction for more than 50 Russian specialists and 25 foreign experts, including independent observers. In total, 2134 urine and 479 blood samples were delivered to the laboratory and analyzed during the Olympic Games (OG), and 403 urine and 108 blood samples - during the Paralympic Games (PG). The number of erythropoietin tests requested in urine was 946 and 166 at the OG and PG, respectively. Though included in the test distribution plan, a growth hormone analysis was cancelled by the Organizing Committee just before the Games. Several adverse analytical findings have been reported including pseudoephedrine (1 case), methylhexaneamine (4 cases), trimetazidine (1 case), dehydrochloromethyltestosterone (1 case), clostebol (1 case), and a designer stimulant N-ethyl-1-phenylbutan-2-amine (1 case). Copyright © 2014 John Wiley & Sons, Ltd.
Fan, Hua; Chen, Peihong; Wang, Chaozhan; Wei, Yinmao
2016-05-27
Zirconium-doped magnetic microspheres (Zr-Fe3O4) for the selective enrichment of cis-diol-containing biomolecules were easily synthesized via a one-step hydrothermal method. Characterization of the microspheres revealed that zirconium was successfully doped into the lattice of Fe3O4 at a doping level of 4.0 at%. Zr-Fe3O4 possessed good magnetic properties and high specificity towards cis-diol molecules, as shown using 28 compounds. For ribonucleosides, the adsorbent not only has favorable anti-interferential abilities but also has a high adsorption capacity up to 159.4μmol/g. As an example of a real application, four ribonucleosides in urine were efficiently enriched and detected via magnetic solid-phase extraction coupled with high-performance liquid chromatography. Under the optimized extraction conditions, the detection limits were determined to be between 0.005 and 0.017μg/mL, and the linearities ranged from 0.02 to 5.00μg/mL (R≥0.996) for these analytes. The accuracy of the analytical method was examined by studying the relative recoveries of the analytes in real urine samples, with recoveries varying from 77.8% to 119.6% (RSDs<10.6%, n=6). The results indicate that Zr-Fe3O4 is a suitable adsorbent for the analysis of cis-diol-containing biomolecules in practical applications. Copyright © 2016 Elsevier B.V. All rights reserved.
Pediatric reference intervals for random urine calcium, phosphorus and total protein.
Slev, Patricia R; Bunker, Ashley M; Owen, William E; Roberts, William L
2010-09-01
The aim of this study was to establish age appropriate reference intervals for calcium (Ca), phosphorus (P) and total protein (UTP) in random urine samples. All analytes were measured using the Roche MODULAR P analyzer and normalized to creatinine (Cr). Our study cohort consisted of 674 boys and 728 girls between 7 and 17 years old (y.o.), which allowed us to determine the central 95% reference intervals with 90% confidence intervals by non-parametric analysis partitioned by both gender and 2-year age intervals for each analyte [i.e. boys in age group 7-9 years (7-9 boys); girls in age group 7-9 years (7-9 girls), etc.]. Results for the upper limits of the central 95% reference interval were: for Ca/Cr, 0.27 (16,17 y.o.) to 0.46 mg/mg (7-9 y.o.) for the girls and 0.26 (16,17 y.o.) to 0.43 mg/mg (7-9 y.o.) for the boys; for P/Cr, 0.85 (16,17 y.o.) to 1.44 mg/mg (7-9 y.o.) for the girls and 0.87 (16,17 y.o.) to 1.68 mg/mg (7-9 y.o.) for the boys; for UTP/Cr, 0.30 (7-9 y.o.) to 0.34 mg/mg (10-12 y.o.) for the girls and 0.19 (16,17, y.o.) to 0.26 mg/mg (13-15 y.o.) for the boys. Upper reference limits decreased with increasing age, and age was a statistically significant variable for all analytes. Eight separate age- and gender-specific reference intervals are proposed per analyte.
Clauwaert, K M; Van Bocxlaer, J F; De Letter, E A; Van Calenbergh, S; Lambert, W E; De Leenheer, A P
2000-12-01
The popular designer drugs 3, 4-methylenedioxymethamphetamine (MDMA) and 3, 4-methylenedioxyethylamphetamine (MDEA) can be determined in serum, whole blood, and urine, but also in vitreous humor. The latter matrix is interesting when dealing with decomposed bodies in a toxicological setting. After extraction, chromatographic separation was achieved on a narrow-bore C(18) column by gradient elution with fluorometric detection; results were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was linear over the range of 2-1000 microg/L for whole blood, serum, and vitreous humor, and 0.1-5 mg/L for urine. Extraction recoveries were >70%, imprecision (CV) was 2.5-19%, and analytical recoveries were 95.5-104.4%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.8 and 2 microg/L, respectively, for whole blood, serum, and vitreous humor, and 2.5 microg/L and 0.1 mg/L, respectively, for urine. Excellent correlations between the quantitative LC-fluorescence and LC-MS/MS results were obtained. We found the following concentrations in a thanatochemical distribution study in rabbits: in serum, 5.3-685 microg/L for MDMA and from the LOQ to 14.5 microg/L for 3, 4-methylenedioxyamphetamine (MDA); in whole blood, 19.7-710 microg/L for MDMA and from the LOQ to 17.8 microg/L for MDA; in vitreous humor, 12.1-97.8 microg/L for MDMA and from the LOQ to 3.86 microg/L for MDA. In routine toxicological urine samples, concentrations ranged from LOQ to 14.62 mg/L for MDA, from LOQ to 157 mg/L for MDMA, and from LOQ to 32.54 mg/L for MDEA. The HPLC method described is sensitive, specific, and suitable for the determination of MDMA, MDEA, and MDA in whole blood, serum, vitreous humor, and urine.
Mokube, Morike Ngoe; Atashili, Julius; Halle-Ekane, Gregory Edie; Ikomey, George M.; Ndumbe, Peter M.
2013-01-01
Background Bacteriuria is associated with significant maternal and foetal risks. However, its prevalence is not known in our community. Objectives This study was carried out to determine the prevalence and predictors of bacteriuria in pregnant women of the Buea Health District (BHD) as well as the antibiotic sensitivity patterns of bacterial isolates. It also sought to determine the diagnostic performance of the nitrite and leucocyte esterase tests in detecting bacteriuria in these women. Methods An observational analytic cross-sectional study was carried out amongst pregnant women attending selected antenatal care centres in Buea. We recruited 102 consenting pregnant women for the study. Demographic and clinical data were collected using structured questionnaires. Clean catch midstream urine was collected from each participant in sterile leak proof containers. Samples were examined biochemically, microscopically and by culture. Significant bacteriuria was defined as the presence of ≥108 bacteria/L of cultured urine. Identification and susceptibility of isolates was performed using API 20E and ATB UR EU (08) (BioMerieux, Marcy l'Etoile, France). Results Significant bacteriuria was found in the urine of 24 of the 102 women tested giving a bacteriuria prevalence of 23.5% in pregnant women of the BHD. Asymptomatic bacteriuria was detected in 8(7.8%) of the women. There was no statistically significant predictor of bacteriuria. Escherichia coli were the most isolated (33%) uropathogens and were 100% sensitive to cefixime, cefoxitin and cephalothin. The nitrite and leucocyte esterase tests for determining bacteriuria had sensitivities of 8%, 20.8% and specificities of 98.7% and 80.8% respectively. Conclusion Bacteriuria is frequent in pregnant women in the BHD suggesting the need for routine screening by urine culture. Empiric treatment with cefixime should be instituted until results of urine culture and sensitivity are available. Nitrite and leucocyte esterase tests were not sensitive enough to replace urine culture as screening tests. PMID:23976983
Ultrasonic-based membrane aided sample preparation of urine proteomes.
Jesus, Jemmyson Romário; Santos, Hugo M; López-Fernández, H; Lodeiro, Carlos; Arruda, Marco Aurélio Zezzi; Capelo, J L
2018-02-01
A new ultrafast ultrasonic-based method for shotgun proteomics as well as label-free protein quantification in urine samples is developed. The method first separates the urine proteins using nitrocellulose-based membranes and then proteins are in-membrane digested using trypsin. The enzymatic digestion process is accelerated from overnight to four minutes using a sonoreactor ultrasonic device. Overall, the sample treatment pipeline comprising protein separation, digestion and identification is done in just 3h. The process is assessed using urine of healthy volunteers. The method shows that male can be differentiated from female using the protein content of urine in a fast, easy and straightforward way. 232 and 226 proteins are identified in urine of male and female, respectively. From this, 162 are common to both genders, whilst 70 are unique to male and 64 to female. From the 162 common proteins, 13 are present at levels statistically different (p < 0.05). The method matches the analytical minimalism concept as outlined by Halls, as each stage of this analysis is evaluated to minimize the time, cost, sample requirement, reagent consumption, energy requirements and production of waste products. Copyright © 2017 Elsevier B.V. All rights reserved.
Kazubek-Zemke, Maja; Rybka, Jacek; Marchewka, Zofia; Rybka, Wojciech; Pawlik, Krzysztof; Długosz, Anna
2014-11-14
The early diagnosis of the nephrotoxic effect of xenobiotics and drugs is still an unsolved problem. Recent studies suggest a correlation between the nephrotoxic activity of xenobiotics and increased concentration of amino acids in urine. The presented study was focused on the application of GLC-MS method for amino acids profiling in human urine as a noninvasive method for monitoring of kidney condition and tubular injury level. The analytic method is based on the conversion of the amino acids present in the sample to tert-butyldimethylsilyl (TBDMS) derivatives and their analysis by gas-liquid chromatography-mass spectrometry (GLC-MS). The procedure of urine sample preparation for chromatographic analysis was optimized. The presence of 12 amino acids in most of the tested healthy human urine samples was detected. The significant differences in the levels of particular amino acids between patients with tubular injury and healthy controls were found, especially for lysine, valine, serine, alanine and leucine (on average 30.0, 7.5, 3.6, 2.9 and 0.5 fold respectively). We found that this approach based on GLC-MS detection can be used in nephrotoxicity studies for urine amino acids monitoring in exposure to xenobiotics and drugs.
Accorsi, Antonio; Valenti, Simona; Barbieri, Anna; Raffi, Giovanni Battista; Violante, Francesco Saverio
2003-03-01
Assessment of individual exposures to sevoflurane plus nitrous oxide (N(2)O) by biological monitoring of unmodified analytes in post-shift urine of exposed personnel. Anaesthetics in urine and breathing area were monitored in 124 subjects in 11 operating theatres. Passive samplers were collected after 2.5-7 h of exposure, at the same time as post-shift urinary samples, to evaluate the individual time-weighted average (TWA) exposures to sevoflurane and N(2)O. A static headspace sampler coupled with a gas chromatograph mass spectrometer was used for analytical determinations (sensitivity sufficient to reveal biological/environmental exposures of 0.1 microg/l(urine) and 50 ppb for sevoflurane, and 1 microg/l(urine) and 80 ppb for N(2)O). Median (range) post-shift urinary and environmental values were 1.2 microg/l(urine) (0.1-5.0) and 0.4 ppm (0.05-3.0) for sevoflurane ( n=107) and 10.9 microg/l(urine) (0.5-74.9) and 8.6 ppm (0.2-123.4) for N(2)O ( n=121) (all low-exposure range). At log-log regression, urinary levels closely correlated with environmental data (sevoflurane, r(2)=0.7538; N(2)O, r(2)=0.8749). Biological equivalent limits (BELs) based on National Institute for Occupational Safety and Health (NIOSH) TWA exposure limits, calculated as means of regression slope and y-intercept, were 3.6 microg/l(urine) for sevoflurane (corresponding to 2 ppm) and 22.3 microg/l(urine) for N(2)O (corresponding to 25 ppm). Individual "mixture BELs", which we calculated by applying the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) mix formula to biomarker values and using the obtained NIOSH-based BELs as a reference, closely correlated with mixture TLVs (rho=0.816, Lin's concordance test). CONCLUSIONS. We propose urinary sevoflurane as a new, specific, internal dose biomarker for routine biological monitoring of personal exposures among operating-theatre personnel, and use of reliable "mixture BELs" to provide safer levels of internal exposure for workers exposed to mixtures of sevoflurane and N(2)O, and conceivably also to other mixtures of toxicants with possible additive effects.
Semenistaya, Ekaterina; Zvereva, Irina; Thomas, Andreas; Thevis, Mario; Krotov, Grigory; Rodchenkov, Grigory
2015-10-01
Growth hormone releasing peptides (GHRPs) stimulate secretion of endogenous growth hormone and are listed on the World Anti-Doping Agency (WADA) Prohibited List. To develop an effective method for GHRPs anti-doping control we have investigated metabolites of GHRP-1, GHRP-2, GHRP-6, Hexarelin, and Ipamorelin in urine after nasal administration. Each compound was administrated to one volunteer. Samples were collected for 2 days after administration, processed by solid-phase extraction on weak cation exchange cartridges and analyzed by means of nano-liquid chromatography - high resolution mass spectrometry. Six metabolites of GHRP-1 were identified. GHRP-1 in the parent form was not detected. GHRP-1 (2-4) free acid was detected in urine up to 27 h. GHRP-2, GHRP-2 free acid and GHRP-2 (1-3) free acid were detected in urine up to 47 h after administration. GHRP-6 was mostly excreted unchanged and detected in urine 23 h after administration, its metabolites were detectable for 12 h only. Hexarelin and Ipamorelin metabolized intensively and were excreted as a set of parent compounds with metabolites. Hexarelin (1-3) free acid and Ipamorelin (1-4) free acid were detected in urine samples after complete withdrawal of parent substances. GHRPs and their most prominent metabolites were included into routine ultra-pressure liquid chromatography-tandem mass spectrometry procedure. The method was fully validated, calibration curves of targeted analytes were obtained and excretion curves of GHRPs and their metabolites were plotted. Our results confirm that the detection window after GHRPs administration depends on individual metabolism, drug preparation form and the way of administration. Copyright © 2015 John Wiley & Sons, Ltd.
Möller, Kristina; Crescenzi, Carlo; Nilsson, Ulrika
2004-01-01
Diphenyl phosphate is a hydrolysis product and possible metabolite of the flame retardant and plasticiser additive triphenyl phosphate. A molecularly imprinted polymer solid-phase extraction (MISPE) method for extracting diphenyl phosphate from aqueous solutions has been developed and compared with SPE using a commercially available mixed-mode anion exchanger. The imprinted polymer was prepared using 2-vinylpyridine (2-Vpy) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, and a structural analogue of the analyte as the template molecule. The imprinted polymer was evaluated for use as a SPE sorbent, in tests with both aqueous standards and spiked urine samples, by comparing recovery and breakthrough data obtained using the imprinted form of the polymer and a non-imprinted form (NIP). Extraction from aqueous solutions resulted in more than 80% recovery. Adsorption by the molecularly imprinted polymer (MIP) was non-selective, but selectivity was achieved by selective desorption in the wash steps. Diphenyl phosphate could also be selectively extracted from urine samples, although the urine matrix reduced the capacity of the MISPE cartridges. Recoveries from urine extraction were higher than 70%. It was important to control pH during sample loading. The MISPE method was found to yield a less complex LC-ESI-MS chromatogram of the urine extracts compared with the mixed-mode anion-exchanger method. An LC-ESI-MS method using a Hypercarb LC column with a graphitised carbon stationary phase was also evaluated for organophosphate diesters. LC-ESI-MS using negative-ion detection in selected ion monitoring (SIM) mode was shown to be linear for diphenyl phosphate in the range 0.08-20 ng microL(-1).
Pu, Fan; McKinney, Andrew R; Stenhouse, Allen M; Suann, Craig J; McLeod, Malcolm D
2004-12-25
A study of the equine phase II metabolism of the anabolic agent boldenone is reported. Boldenone sulfate, boldenone glucuronide and their C17-epimers were synthesised as reference standards in our lab and a method was developed for their detection in a horse urine matrix. Solid phase extraction was used to purify the analytes, which were then detected by ion trap LC/MS. Negative and positive ionisation mode MS(2) were used for the detection of sulfate and glucuronide conjugates, respectively. Boldenone sulfate and 17-epiboldenone glucuronide were detected as the major and minor phase II metabolites, respectively, in horse urine samples collected following the administration of boldenone undecylenate by intramuscular injection.
Impact of enzymatic and alkaline hydrolysis on CBD concentration in urine.
Bergamaschi, Mateus M; Barnes, Allan; Queiroz, Regina H C; Hurd, Yasmin L; Huestis, Marilyn A
2013-05-01
A sensitive and specific analytical method for cannabidiol (CBD) in urine was needed to define urinary CBD pharmacokinetics after controlled CBD administration, and to confirm compliance with CBD medications including Sativex-a cannabis plant extract containing 1:1 ∆(9)-tetrahydrocannabinol (THC) and CBD. Non-psychoactive CBD has a wide range of therapeutic applications and may also influence psychotropic smoked cannabis effects. Few methods exist for the quantification of CBD excretion in urine, and no data are available for phase II metabolism of CBD to CBD-glucuronide or CBD-sulfate. We optimized the hydrolysis of CBD-glucuronide and/or -sulfate, and developed and validated a GC-MS method for urinary CBD quantification. Solid-phase extraction isolated and concentrated analytes prior to GC-MS. Method validation included overnight hydrolysis (16 h) at 37 °C with 2,500 units β-glucuronidase from Red Abalone. Calibration curves were fit by linear least squares regression with 1/x (2) weighting with linear ranges (r(2) > 0.990) of 2.5-100 ng/mL for non-hydrolyzed CBD and 2.5-500 ng/mL for enzyme-hydrolyzed CBD. Bias was 88.7-105.3 %, imprecision 1.4-6.4 % CV and extraction efficiency 82.5-92.7 % (no hydrolysis) and 34.3-47.0 % (enzyme hydrolysis). Enzyme-hydrolyzed urine specimens exhibited more than a 250-fold CBD concentration increase compared to alkaline and non-hydrolyzed specimens. This method can be applied for urinary CBD quantification and further pharmacokinetics characterization following controlled CBD administration.
Beucher, Laure; Dervilly-Pinel, Gaud; Cesbron, Nora; Penot, Mylène; Gicquiau, Audrey; Monteau, Fabrice; Le Bizec, Bruno
2017-02-01
Currently under development for therapeutic purposes in human medicine, non-steroidal selective androgen receptor modulators (non-steroidal SARMs) are also known to impact growth associated pathways. As such, they present a potential for abuse in sports and food-producing animals as interesting alternative anabolic substances. Forbidden since 2008 by the World Anti-Doping Agency (WADA) these compounds are however easily available and could be (mis)used in livestock production as growth promoters. To prevent such practices, dedicated analytical strategies have to be developed for specific and sensitive detection of these compounds in biological matrices. Using an innovative analytical platform constituted of supercritical fluid chromatography coupled to ion mobility-mass spectrometry, the present study enabled efficient separation and identification in urine of 4 of these drugs (andarine, bicalutamide, hydroxyflutamide, and enobosarm) in accordance with European Union criteria (Commission Decision 2002/657/EC). Besides providing information about compounds structure and behaviour in gas phase, such a coupling enabled reaching low limits of detection (LOD < 0.05 ng.mL -1 for andarine and limits of detection < 0.005 ng.mL -1 for the three others) in urine with good repeatability (CV < 21 %). The workflow has been applied to quantitative determination of enobosarm elimination in urine of treated bovine (200 mg, oral). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Dumasia, M C; Ginn, A; Hyde, W; Peterson, J; Houghton, E
2003-05-25
Rimadyl (carprofen) was administered orally to the racing greyhound at a dose of 2.2 mg kg(-1). Following both alkaline and enzymatic hydrolysis, postadministration urine samples were extracted by mixed mode solid-phase extraction (SPE) cartridges to identify target analyte(s) for forensic screening and confirmatory analysis methods. The acidic isolates were derivatised as trimethylsilyl ethers (TMS) and analysed by gas chromatography-mass spectrometry (GC-MS). Carprofen and five phase I metabolites were identified. Positive ion electron ionisation (EI(+)) mass spectra of the TMS derivatives of carprofen and its metabolites show a diagnostic base peak at M(+)*. -117 corresponding to the loss of COO-Si-(CH(3))(3) group as a radical. GC-MS with positive ion ammonia chemical ionisation (CI(+)) of the compounds provided both derivatised molecular mass and some structural information. Deutromethylation-TMS derivatisation was used to distinguish between aromatic and aliphatic oxidations of carprofen. The drug is rapidly absorbed, extensively metabolised and excreted as phase II conjugates in urine. Carprofen, three aromatic hydroxy and a minor N-hydroxy metabolite were detected for up to 48 h. For samples collected between 2 and 8 h after administration, the concentration of total carprofen ranged between 200 and 490 ng ml(-1). The major metabolite, alpha-hydroxycarprofen was detected for over 72 h and therefore can also be used as a marker for the forensic screening of carprofen in greyhound urine.
The Potential Role of Oral Fluid in Antidoping Testing
Anizan, Sebastien; Huestis, Marilyn A.
2015-01-01
BACKGROUND Currently, urine and blood are the only matrices authorized for antidoping testing by the World Anti-Doping Agency (WADA). Although the usefulness of urine and blood is proven, issues remain for monitoring some drug classes and for drugs prohibited only in competition. The alternative matrix oral fluid (OF) may offer solutions to some of these issues. OF collection is easy, noninvasive, and sex neutral and is directly observed, limiting potential adulteration, a major problem for urine testing. OF is used to monitor drug intake in workplace, clinical toxicology, criminal justice, and driving under the influence of drugs programs and potentially could complement urine and blood for antidoping testing in sports. CONTENT This review outlines the present state of knowledge and the advantages and limitations of OF testing for each of the WADA drug classes and the research needed to advance OF testing as a viable alternative for antidoping testing. SUMMARY Doping agents are either prohibited at all times or prohibited in competition only. Few OF data from controlled drug administration studies are available for substances banned at all times, whereas for some agents prohibited only in competition, sufficient data may be available to suggest appropriate analytes and cutoffs (analytical threshold concentrations) to identify recent drug use. Additional research is needed to characterize the disposition of many banned substances into OF; OF collection methods and doping agent stability in OF also require investigation to allow the accurate interpretation of OF tests for antidoping monitoring. PMID:24153253
Cook, Sarah F; King, Amber D; van den Anker, John N; Wilkins, Diana G
2015-12-15
Drug metabolism plays a key role in acetaminophen (paracetamol)-induced hepatotoxicity, and quantification of acetaminophen metabolites provides critical information about factors influencing susceptibility to acetaminophen-induced hepatotoxicity in clinical and experimental settings. The aims of this study were to develop, validate, and apply high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) methods for simultaneous quantification of acetaminophen, acetaminophen-glucuronide, acetaminophen-sulfate, acetaminophen-glutathione, acetaminophen-cysteine, and acetaminophen-N-acetylcysteine in small volumes of human plasma and urine. In the reported procedures, acetaminophen-d4 and acetaminophen-d3-sulfate were utilized as internal standards (IS). Analytes and IS were recovered from human plasma (10μL) by protein precipitation with acetonitrile. Human urine (10μL) was prepared by fortification with IS followed only by sample dilution. Calibration concentration ranges were tailored to literature values for each analyte in each biological matrix. Prepared samples from plasma and urine were analyzed under the same HPLC-ESI-MS/MS conditions, and chromatographic separation was achieved through use of an Agilent Poroshell 120 EC-C18 column with a 20-min run time per injected sample. The analytes could be accurately and precisely quantified over 2.0-3.5 orders of magnitude. Across both matrices, mean intra- and inter-assay accuracies ranged from 85% to 112%, and intra- and inter-assay imprecision did not exceed 15%. Validation experiments included tests for specificity, recovery and ionization efficiency, inter-individual variability in matrix effects, stock solution stability, and sample stability under a variety of storage and handling conditions (room temperature, freezer, freeze-thaw, and post-preparative). The utility and suitability of the reported procedures were illustrated by analysis of pharmacokinetic samples collected from neonates receiving intravenous acetaminophen. Copyright © 2015 Elsevier B.V. All rights reserved.
Pharmacokinetics of reduced iso-α-acids in volunteers following clear bottled beer consumption.
Rodda, Luke N; Gerostamoulos, Dimitri; Drummer, Olaf H
2015-05-01
Reduced iso-α-acids (reduced IAA) consisting of the rho-, tetrahydro- and hexahydro-IAA groups (RIAA, TIAA and HIAA, respectively) are ingredient congeners specific to beer and generally found in clear and also occasionally green bottled beer. Concentrations of reduced IAA were determined in the blood and urine of five volunteers over 6h following the consumption of small volumes of beer containing each of the reduced IAA. The reduced IAA were absorbed and bioavailable with peak concentrations at 0.5h followed by a drop of generally fivefold by 2h. Preliminary pharmacokinetics of these compounds in humans shows relatively small inter-individual differences and an estimated short half-life varying between ∼38 and 46min for the three groups. Comparison of RIAA analyte ratios within the group indicate that some analytes eliminate relatively faster than others and the formation of metabolite products was observed. Preliminary urine analysis showed only unmodified RIAA analytes were detectable throughout 6h and suggests extensive phase I metabolism of TIAA and HIAA analytes. In authentic forensic casework where clear or green bottled beers are consumed, the identification of reduced IAA groups may provide a novel method to target ingredient congeners consistent with beer ingestion and suggest the type of beer consumed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Bozzolino, Cristina; Leporati, Marta; Gani, Federica; Ferrero, Cinzia; Vincenti, Marco
2018-02-20
A fast analytical method for the simultaneous detection of 24 β 2 -agonists in human urine was developed and validated. The method covers the therapeutic drugs most commonly administered, but also potentially abused β 2 -agonists. The procedure is based on enzymatic deconjugation with β-glucuronidase followed by SPE clean up using mixed-phase cartridges with both ion-exchange and lipophilic properties. Instrumental analysis conducted by UHPLC-MS/MS allowed high peak resolution and rapid chromatographic separation, with reduced time and costs. The method was fully validated according ISO 17025:2005 principles. The following parameters were determined for each analyte: specificity, selectivity, linearity, limit of detection, limit of quantification, precision, accuracy, matrix effect, recovery and carry-over. The method was tested on real samples obtained from patients subjected to clinical treatment under chronic or acute therapy with either formoterol, indacaterol, salbutamol, or salmeterol. The drugs were administered using pressurized metered dose inhalers. All β 2 -agonists administered to the patients were detected in the real samples. The method proved adequate to accurately measure the concentration of these analytes in the real samples. The observed analytical data are discussed with reference to the administered dose and the duration of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.
Chiesa, Luca Maria; Nobile, Maria; Panseri, Sara; Arioli, Francesco
2017-11-15
The antibiotic overuse in zoothechnics, due to prophylactic and therapeutic treatments, or to their growth-promoting activity, is a major cause for the onset of widespread antibiotic resistance. Of particular relevance to this study, is the antibiotic abuse in pig breeding. Despite the comprehensive literature on residue controls in pig muscle, data on pig urine, a non-invasive, on-farm collectable matrix, are lacking. Therefore, we validated an HPLC-MS/MS method to detect 29 antimicrobials from eight classes and applied it to 43 anonymous pig urine and muscle paired samples and fulfilled the parameters in agreement with the Commission Decision 2002/657/UE. The analytical limits were moreover much lower than the maximum residue limits (MRLs) required by the Commission Regulation 37/2010/UE. In the samples, antibiotics were usually detected at higher frequencies and concentrations in urine than muscle. Urine proved a useful tool to detect antibiotic administration and their excessive use in pig farming is depicted. Copyright © 2017. Published by Elsevier Ltd.
Valenzuela, Aníbal; Lespes, Gaëtane; Quiroz, Waldo; Aguilar, Luis F; Bravo, Manuel A
2014-07-01
A new headspace solid-phase micro-extraction (HS-SPME) method followed by gas chromatography with pulsed flame photometric detection (GC-PFPD) analysis has been developed for the simultaneous determination of 11 organotin compounds, including methyl-, butyl-, phenyl- and octyltin derivates, in human urine. The methodology has been validated by the analysis of urine samples fortified with all analytes at different concentration levels, and recovery rates above 87% and relative precisions between 2% and 7% were obtained. Additionally, an experimental-design approach has been used to model the storage stability of organotin compounds in human urine, demonstrating that organotins are highly degraded in this medium, although their stability is satisfactory during the first 4 days of storage at 4 °C and pH=4. Finally, this methodology was applied to urine samples collected from harbor workers exposed to antifouling paints; methyl- and butyltins were detected, confirming human exposure in this type of work environment. Copyright © 2014 Elsevier B.V. All rights reserved.
Trace drug analysis by surface-enhanced Raman spectroscopy
NASA Astrophysics Data System (ADS)
Farquharson, Stuart; Lee, Vincent Y.
2000-12-01
Drug overdose involves more than 10 percent of emergency room (ER) cases, and a method to rapidly identify and quantify the abused drug is critical to the ability of the ER physician to administer the appropriate care. To this end, we have been developing a surface-enhanced Raman (SER) active material capable of detecting target drugs at physiological concentrations in urine. The SER-active material consists of a metal-doped sol-gel that provides not only a million fold increase in sensitivity but also reproducible measurements. The porous silica network offers a unique environment for stabilizing SER active metal particles and the high surface area increase the interaction between the analyte and metal particles. The sol-gel has been coated on the inside walls of glass samples vials, such that urine specimens may simply be introduced for analysis. Here we present the surface-enhanced Raman spectra of a series of barbiturates, actual urine specimens, and a drug 'spiked' urine specimen. The utility of pH adjustment to suppress dominant biochemicals associated with urine is also presented.
Sirichai, Somsak; Khanatharana, Proespichaya
2008-09-15
Capillary electrophoresis (CE) with UV detection for the simultaneous and short-time analysis of clenbuterol, salbutamol, procaterol, fenoterol is described and validated. Optimized conditions were found to be a 10 mmoll(-1) borate buffer (pH 10.0), an separation voltage of 19 kV, and a separation temperature of 32 degrees C. Detection was set at 205 nm. Under the optimized conditions, analyses of the four analytes in pharmaceutical and human urine samples were carried out in approximately 1 min. The interference of the sample matrix was not observed. The LOD (limits of detection) defined at S/N of 3:1 was found between 0.5 and 2.0 mgl(-1) for the analytes. The linearity of the detector response was within the range from 2.0 to 30 mgl(-1) with correlation coefficient >0.996.
Rapid screening of pharmaceutical drugs using thermal desorption - SALDI mass spectrometry
NASA Astrophysics Data System (ADS)
Grechnikov, A. A.; Kubasov, A. E.; Georgieva, V. B.; Borodkov, A. S.; Nikiforov, S. M.; Simanovsky, Ya O.; Alimpiev, S. S.
2012-12-01
A novel approach to the rapid screening of pharmaceutical drugs by surface assisted laser desorption-ionization (SALDI) mass spectrometry with the rotating ball interface coupled with temperature programmed thermal desorption has been developed. Analytes were thermally desorbed and deposited onto the surface of amorphous silicon substrate attached to the rotating ball. The ball was rotated and the deposited analytes were analyzed using SALDI. The effectiveness of coupling SALDI mass spectrometry with thermal desorption was evaluated by the direct and rapid analysis of tablets containing lidocaine, diphenhydramine and propranolol without any sample pretreatment. The overall duration of the screening procedure was 30÷40 sec. Real urine samples were studied for drug analysis. It is shown that with simple preparation steps, urine samples can be quantitatively analyzed using the proposed technique with the detection limits in the range of 0.2÷0.5 ng/ml.
Beck-Jensen, J E; Kollerup, G; Sørensen, H A; Pors Nielsen, S; Sørensen, O H
1997-07-01
Biochemical markers of bone turnover are used to estimate the rate of bone loss in the individual osteoporotic patient. During recent years it has become increasingly clear that the biological variability of biochemical bone markers has to be taken into consideration in the evaluation of their usefulness in the clinical setting. Eleven premenopausal, 8 perimenopausal and 11 postmenopausal healthy women were included. We assessed the analytical and the biological components of variation for a number of resorptive and formative bone markers: u-hydroxyproline, u-pyridinoline, and u-deoxypyridinoline together with u-calcium and u-creatinine, s-total alkaline phosphatases and s-osteocalcin. Blood and urine samples were collected five times with 7-day intervals. Urinary parameters were expressed as outputs and corrected for creatinine in fasting night urines and second void fasting morning urines. The absolute values differed with a tendency towards increasing values in the postmenopausal women, but the biological variations in relation to menopausal status were not different. The biological variability was much higher for the urinary resorptive markers than for the formative markers in the blood. The critical difference expressing the difference needed between two serial results from the same person to be significant at a 5% level was 15% for s-alkaline phosphatases, 18% for s-osteocalcin, and lowest in the second void fasting morning urines with values of 28% and 34% for u-pyridinoline/creatinine and u-deoxypyridinoline/creatinine, and 50% and 112% for u-hydroxyproline/creatinine and u-calcium/creatinine, respectively. The index of individuality, denoting the individual variation divided by the variation between subjects, was in the range from 0.19 for s-alkaline phosphatases to 1.23 for u-hydroxyproline/minute in second void fasting morning urine making the use of conventional reference intervals difficult. Low indices, however, indicate high test performance and offer the possibility of stratification of persons within a range. The number of samples required to determine the true individual mean value +/- 5% for the single person, ranged from 5 for s-total alkaline phosphatases, 6 for s-osteocalcin, 23 for u-deoxypyridinoline/creatinine in the fasting morning urine to over two hundred for u-calcium analytes. It is concluded that, due to high biological variation, a single measurement of biochemical markers of bone turnover is of limited utility in the individual person. We recommend that routine clinical use of biochemical markers should be restricted until further evidence justifies it.
Potentiometric detection in UPLC as an easy alternative to determine cocaine in biological samples.
Daems, Devin; van Nuijs, Alexander L N; Covaci, Adrian; Hamidi-Asl, Ezat; Van Camp, Guy; Nagels, Luc J
2015-07-01
The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra-high-pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3 ng mL(-1) were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25 ng mL(-1). A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost-effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable. Copyright © 2014 John Wiley & Sons, Ltd.
Silverio, Angelito A; Chung, Wen-Yaw; Cheng, Cheanyeh; Wang, Hai-Lung; Kung, Chien-Min; Chen, Jun; Tsai, Vincent F S
2016-04-01
It is important to control daily diet, water intake and life style as well as monitor the quality of urine for urolithiasis prevention. For decades, many ion-related indices have been developed for predicting the formation of urinary stones or urolithiasis, such as EQUILs, relative supersaturation (RSS), Tiselius indices (TI), Robertson risk factor algorithms (RRFA) and more recently, the Bonn risk index. However, they mostly demand robust laboratory analysis, are work-intensive, and even require complex computational programs to get the concentration patterns of several urine analytes. A simple and fast platform for measuring multi-frequency electrical conductivity (MFEC) of morning spot urine (random urine) to predict the onset of urolithiasis was implemented in this study. The performance thereof was compared to ion-related indices, urine color and specific gravity. The concentrations of relevant ions, color, specific gravity (SG) and MFEC (MFEC tested at 1, 10, 100, 5001 KHz and 1 MHz) of 80 random urine samples were examined after collection. Then, the urine samples were stored at 4 °C for 24 h to determine whether sedimentation would occur or not. Ion-activity product index of calcium oxalate (AP(CaOx) EQ2) was calculated. The correlation between AP(CaOx) EQ2, urine color, SG and MFEC were analyzed. AP(CaOx) EQ2, urine color and MFEC (at 5 frequencies) all demonstrated good prediction (p = 0.01, 0.01, 0.01, respectively) for stone formation. The positive correlation between AP(CaOx) EQ2 and MFEC is also significant (p = 0.01). MFEC provides a good metric for predicting the onset of urolithiasis, which is comparable to conventional ion-related indices and urine color. This technology can be implemented with much ease for objectively monitoring the quality of urine at points-of-care or at home.
Cannabis Use Surveillance by Sweat Analysis.
Gambelunghe, Cristiana; Fucci, Nadia; Aroni, Kyriaki; Bacci, Mauro; Marcelli, Antonio; Rossi, Riccardo
2016-10-01
Sweat testing, an alternative matrix for establishing drug abuse, offers additional benefits to the more common biological samples. The authors developed a procedure using gas chromatography-mass spectrometry to test for Δ9-tetrahydrocannabinol, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid, cannabinol (CBN), and cannabidiol (CBD) in a sweat patch. The results were compared with urine and hair sample results. Urine, hair, and sweat samples were simultaneously collected from 12 patients who were involved, respectively, in forensic case and monitoring abuse. Selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, intraday and interday imprecision, and inaccuracy of the quantification procedure were validated. LODs in hair were 0.05 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.005 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOD for sweat was 0.30 ng/patch for all substances. The LOQ in hair was 0.1 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.01 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOQ was 0.4 ng/patch in sweat for each analyte. Cannabinoid in urine was determined by means of immunochemical screening (cutoff 11-nor-Δ-tetrahydrocannabinol-9-carboxylic acid 50 ng/mL). All subjects tested positive for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid and Δ9-tetrahydrocannabinol in urine and hair. In sweat samples, Δ9-tetrahydrocannabinol was found in all patches (0.4-2.0 ng/patch); 6 cases were positive for CBN (0.4-0.5 ng/patch) and 3 for CBD (0.4-0.6 ng/patch); 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid was never detected in patches. Present sweat analysis results integrated the information from hair and urine and showed that sweat analysis is a suitable, noninvasive method for monitoring compliance with rehabilitation therapy and for detecting recent cumulative use of cannabinoids.
Sen, Indranil; Zou, Wei; Alvaran, Josephine; Nguyen, Linda; Gajek, Ryszard; She, Jianwen
2015-01-01
In order to better distinguish the different toxic inorganic and organic forms of arsenic (As) exposure in individuals, we have developed and validated a simple and robust analytical method for determining the following six As species in human urine: arsenous (III) acid (As-III), As (V) acid, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine (AsB), and arsenocholine. In this method, human urine is diluted using a pH 5.8 buffer, separation is performed using an anion exchange column with isocratic HPLC, and detection is achieved using inductively coupled plasma-MS. The method uses a single mobile phase consisting of low concentrations of both phosphate buffer (5 mM) and ammonium nitrate salt (5 mM) at pH 9.0; this minimizes the column equilibration time and overcomes challenges with separation between AsB and As-III. In addition, As-III oxidation is prevented by degassing the sample preparation buffer at pH 5.8, degassing the mobile phase online at pH 9.0, and by the use of low temperature (-70 °C) and flip-cap airtight tubes for long term storage of samples. The method was validated using externally provided reference samples. Results were in agreement with target values at varying concentrations and successfully passed external performance test criteria. Internal QC samples were prepared and repeatedly analyzed to assess the method's long-term precision, and further analyses were completed on anonymous donor urine to assess the quality of the method's baseline separation. Results from analyses of external reference samples agreed with target values at varying concentrations, and results from precision studies yielded absolute CV values of 3-14% and recovery from 82 to 115% for the six As species. Analysis of anonymous donor urine confirmed the well-resolved baseline separation capabilities of the method for real participant samples.
Kato, Kayoko; Kalathil, Akil A; Patel, Ayesha M; Ye, Xiaoyun; Calafat, Antonia M
2018-06-14
Per- and polyfluoroalkyl substances (PFAS), man-made chemicals with variable length carbon chains containing the perfluoroalkyl moiety (C n F 2n+1 -), are used in many commercial applications. Since 1999-2000, several long-chain PFAS, including perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA), have been detected at trace levels in the blood of most participants of the National Health and Nutrition Examination Survey (NHANES)-representative samples of the U.S. general population-while short-chain PFAS have not. Lower detection frequencies and concentration ranges may reflect lower exposure to short-chain PFAS than to PFOS or PFOA or that, in humans, short-chain PFAS efficiently eliminate in urine. We developed on-line solid phase extraction-HPLC-isotope dilution-MS/MS methods for the quantification in 50 μL of urine or serum of 15 C 3 -C 11 PFAS (C 3 only in urine), and three fluorinated alternatives used as PFOA or PFOS replacements: GenX (ammonium salt of 2,3,3,3,-tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy)-propanoate, also known as HFPO-DA), ADONA (ammonium salt of 4,8-dioxa-3H-perfluorononanoate), and 9Cl-PF3ONS (9-chlorohexadecafluoro-3-oxanonane-1-sulfonate), main component of F53-B. Limit of detection for all analytes was 0.1 ng/mL. To validate the method, we analyzed 50 commercial urine/serum paired samples collected in 2016 from U.S. volunteers with no known exposure to the chemicals. In serum, detection frequency and concentration patterns agreed well with those from NHANES. By contrast, except for perfluorobutanoate, we did not detect long-chain or short-chain PFAS in urine. Also, we did not detect fluorinated alternatives in either urine or serum. Together, these results suggest limited exposure to both short-chain PFAS and select fluorinated alternatives in this convenience population. Copyright © 2018. Published by Elsevier Ltd.
Culver, B D; Shen, P T; Taylor, T H; Lee-Feldstein, A; Anton-Culver, H; Strong, P L
1994-01-01
Daily dietary-boron intake and on-the-job inspired boron were compared with blood- and urine-boron concentrations in workers engaged in packaging and shipping borax. Fourteen workers handling borax at jobs of low, medium, and high dust exposures were sampled throughout full shifts for 5 consecutive days each. Airborne borax concentrations ranged from means of 3.3 mg/m3 to 18 mg/m3, measured gravimetrically. End-of-shift mean blood-boron concentrations ranged from 0.11 to 0.26 microgram/g; end-of-shift mean urine concentrations ranged from 3.16 to 10.72 micrograms/mg creatinine. Creatinine measures were used to adjust for differences in urine-specific gravity such that 1 ml of urine contains approximately 1 mg creatinine. There was no progressive increase in end-of-shift blood- or urine-boron concentrations across the days of the week. Urine testing done at the end of the work shift gave a somewhat better estimate of borate exposure than did blood testing, was sampled more easily, and was analytically less difficult to perform. Personal air samplers of two types were used: one, the 37-mm closed-face, two-piece cassette to estimate total dust and the other, the Institute of Occupational Medicine (IOM) sampler to estimate inspirable particulate mass. Under the conditions of this study, the IOM air sampler more nearly estimated human exposure as measured by blood- and urine-boron levels than did the sampler that measured total dust.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7889874
Sample handling for mass spectrometric proteomic investigations of human urine.
Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid
2008-09-01
Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Schwertner, Harvey A; Kong, Suk Bin
2005-03-09
Modafinil (Provigil) is a new wake-promoting drug that is being used for the management of excessive sleepiness in patients with narcolepsy. It has pharmacological properties similar to that of amphetamine, but without some of the side effects associated with amphetamine-like stimulants. Since modafinil has the potential to be abused, accurate drug-screening methods are needed for its analysis. In this study, we developed a high-performance liquid-chromatographic procedure (HPLC) for the quantitative analysis of modafinil in plasma and urine. (Phenylthio)acetic acid was used as an internal standard for the analysis of both plasma and urine. Modafinil was extracted from urine and plasma with ethyl acetate and ethyl acetate-acetic acid (100:1, v/v), respectively, and analyzed on a C18 reverse phase column with methanol-water-acetic acid (500:500:1, v/v) as the mobile phase. Recoveries from urine and plasma were 80.0 and 98.9%, respectively and the limit of quantitation was 0.1 microg/mL at 233 nm. Forty-eight 2-h post-dose urine samples from sham controls and from individuals taking 200 or 400 mg of modafinil were analyzed without knowledge of drug administration. All 16-placebo urine samples and all 32 2-h post-dose urine samples were correctly classified. The analytical procedure is accurate and reproducible and can be used for therapeutic drug monitoring, pharmacokinetic studies, and drug abuse screening.
Orlovius, A K; Guddat, S; Gütschow, M; Thevis, M; Schänzer, W
2013-11-01
Fenoterol, a fast-acting β2-adrenergic agonist, is used in the therapy of obstructive pulmonary diseases and for the inhibition of premature labour obstetrics. Doping control for β2-agonists, which are prohibited in sports by the World Anti-Doping Agency, is commonly performed by liquid chromatography/mass spectrometry after hydrolysis of phase II metabolites. The continuing development of analytical procedures has led to direct injection of urine samples without sample preparation becoming a viable tool. For the detection of substances without sample preparation, including hydrolysis, detailed information of the phase II metabolism of the substances is essential. In this study, human S9 fractions of different tissues and two recombinant sulfotransferases were investigated for their potential to form fenoterol sulfoconjugates, which were characterised in detail. Two mono-sulfoconjugates and one bis-sulfoconjugate were synthesised and their structures confirmed by liquid chromatography–high-resolution/high-accuracy mass spectrometry. All of the metabolites were identified as esterified phenolic compounds. Excretion studies with orally and inhalatively administered fenoterol proved the occurrence of the sulfoconjugates in vivo. Inhalatively administered fenoterol resulted in the detection of the two monosulfoconjugates in low amounts in urine due to the lower inhalation dose of fenoterol compared to the oral dose. After oral uptake of fenoterol, the two mono-sulfoconjugates and a fenoterol bis-sulfoconjugate were detected in urine. This is the first report of the bis-sulfoconjugate.
Zhu, Linli; Xu, Hui
2014-09-01
Detection of monohydroxy polycyclic aromatic hydrocarbons metabolites in urine is an advisable and valid method to assess human environmental exposure to polycyclic aromatic hydrocarbons. In this work, novel Fe3O4/graphene oxide composites were prepared and their application in the magnetic solid-phase extraction of monohydroxy polycyclic aromatic hydrocarbons in urine was investigated by coupling with liquid chromatography and mass spectrometry. In the hybrid material, superparamagnetic Fe3O4 nanoparticles provide fast separation to simplify the analytical process and graphene oxide provides a large functional surface for the adsorption. The prepared magnetic nanocomposites were characterized by X-ray diffraction, scanning electron microscopy, transmission electron microscopy, and vibrating sample magnetometry. The experimental conditions were optimized systematically. Under the optimal conditions, the recoveries of these compounds were in the range of 98.3-125.2%, the relative standard deviations ranged between 6.8 and 15.5%, and the limits of detection were in the range of 0.01-0.15 ng/mL. The simple, quick, and affordable method was successfully used in the analysis of human urinary monohydroxy polycyclic aromatic hydrocarbons in two different cities. The results indicated that the monohydroxy polycyclic aromatic hydrocarbons level in human urine can provide useful information for environmental exposure to polycyclic aromatic hydrocarbons. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liao, Keren; Mei, Meng; Li, Haonan; Huang, Xiaojia; Wu, Cuiqin
2016-02-01
The development of a simple and sensitive analytical approach that combines multiple monolithic fiber solid-phase microextraction with liquid desorption followed by high-performance liquid chromatography with diode array detection is proposed for the determination of trace levels of seven steroid sex hormones (estriol, 17β-estradiol, testosterone, ethinylestradiol, estrone, progesterone and mestranol) in water and urine matrices. To extract the target analytes effectively, multiple monolithic fiber solid-phase microextraction based on a polymeric ionic liquid was used to concentrate hormones. Several key extraction parameters including desorption solvent, extraction and desorption time, pH value and ionic strength in sample matrix were investigated in detail. Under the optimal experimental conditions, the limits of detection were found to be in the range of 0.027-0.12 μg/L. The linear range was 0.10-200 μg/L for 17β-estradiol, 0.25-200 μg/L estriol, ethinylestradiol and estrone, and 0.50-200 μg/L for the other hormones. Satisfactory linearities were achieved for analytes with the correlation coefficients above 0.99. Acceptable method reproducibility was achieved by evaluating the repeatability and intermediate precision with relative standard deviations of both less than 8%. The enrichment factors ranged from 54- to 74-fold. Finally, the proposed method was successfully applied to the analysis of steroid sex hormones in environmental water samples and human urines with spiking recoveries ranged from 75.6 to 116%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A simple {sup 197}Hg RNAA procedure for the determination of mercury in urine, blood, and tissue
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blotcky, A.J.; Rack, E.P.; Meade, A.G.
1995-12-31
Mercury has been implicated as a causal agent in such central nervous system diseases as Alzheimer`s and Parkinson`s. Consequently, there has been increased interest in the determination of ultra-trace-level mercury in biological matrices, especially in tissue. While such nonnuclear techniques as cold vapor atomic absorption spectrometry and cold vapor atomic fluorescence spectrometry have been employed routinely for mercury determinations in urine and blood, there is a paucity of nonnuclear techniques for the determination of mercury in the low parts-per-billion range in biological tissue. As pointed out by Fardy and Warner, instrumental and radiochemical neutron activation analysis (INAA and RNAA) requiremore » no blank determinations in contrast to nonnuclear analytical techniques employing digestion and/or chemical operations. Therefore, INAA and RNAA become the obvious choices for determination of ultra-trace levels of mercury in tissue. Most separation methods reported in the literature require different and separate methodologies for mercury determinations in urine, blood, or tissue. The purposes of this study are to develop a single methodology for the determination of low levels of mercury in all biological matrices by RNAA and to optimize parameters necessary for an efficacious trace-level determination. Previously, few studies have taken into account the effects of the Szilard-Chalmers reactions of the radioactivatable analyte within a biological matrix. It also would appear that little attention has been given to the optimum postirradiation carrier concentration of the analyte species necessary. This study discusses these various considerations.« less
Guan, Fuyu; Uboh, Cornelius E; Soma, Lawrence R; You, Youwen; Li, Xiaoqing; McDonnell, Sue
2012-01-01
19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts due to the analytical procedure. The present study was undertaken to determine whether NAED and nandrolone detected in plasma and urine samples collected from stallions are truly endogenous or artifacts from sample processing. To answer this question, fresh plasma and urine samples from ≥8 stallions were analyzed for the two AASs, soon after collection, by liquid chromatography hyphenated to tandem mass spectrometry (LC-MS/MS). NAED and nandrolone were not detected in fresh plasma samples but detected in the same samples post storage. Concentrations of both AASs increased with storage time, and the increases were greater at a higher storage temperature (37°C versus 4°C, and ambient temperature versus 4°C). Although NAED was detected in some fresh stallion urine samples, its concentration (<407 pg/mL) was far lower (<0.4%) than that in the same samples post storage (at ambient temperature for 15 days). Nandrolone was not detected in most of fresh urine samples but detected in the same samples post storage. Based on these results, it is concluded that all NAED and nandrolone detected in stored plasma samples of stallions and most of them in the stored urine samples are not from endogenous origins but spontaneously generated during sample storage, most likely from spontaneous decarboxylation of androstenedione-19-oic acid and testosterone-19-oic acid. To our knowledge, it is the first time that all NAED and nandrolone detected in plasma of stallions and most of them detected in the urine have been shown to be spontaneously generated in vitro during sample storage. This finding would have significant implications with regard to the regulation of the two steroids in horse racing. Copyright © 2011 Elsevier Ltd. All rights reserved.
Reference intervals for 24 laboratory parameters determined in 24-hour urine collections.
Curcio, Raffaele; Stettler, Helen; Suter, Paolo M; Aksözen, Jasmin Barman; Saleh, Lanja; Spanaus, Katharina; Bochud, Murielle; Minder, Elisabeth; von Eckardstein, Arnold
2016-01-01
Reference intervals for many laboratory parameters determined in 24-h urine collections are either not publicly available or based on small numbers, not sex specific or not from a representative sample. Osmolality and concentrations or enzymatic activities of sodium, potassium, chloride, glucose, creatinine, citrate, cortisol, pancreatic α-amylase, total protein, albumin, transferrin, immunoglobulin G, α1-microglobulin, α2-macroglobulin, as well as porphyrins and their precursors (δ-aminolevulinic acid and porphobilinogen) were determined in 241 24-h urine samples of a population-based cohort of asymptomatic adults (121 men and 120 women). For 16 of these 24 parameters creatinine-normalized ratios were calculated based on 24-h urine creatinine. The reference intervals for these parameters were calculated according to the CLSI C28-A3 statistical guidelines. By contrast to most published reference intervals, which do not stratify for sex, reference intervals of 12 of 24 laboratory parameters in 24-h urine collections and of eight of 16 parameters as creatinine-normalized ratios differed significantly between men and women. For six parameters calculated as 24-h urine excretion and four parameters calculated as creatinine-normalized ratios no reference intervals had been published before. For some parameters we found significant and relevant deviations from previously reported reference intervals, most notably for 24-h urine cortisol in women. Ten 24-h urine parameters showed weak or moderate sex-specific correlations with age. By applying up-to-date analytical methods and clinical chemistry analyzers to 24-h urine collections from a large population-based cohort we provide as yet the most comprehensive set of sex-specific reference intervals calculated according to CLSI guidelines for parameters determined in 24-h urine collections.
Leese, Elizabeth; Morton, Jackie; Gardiner, Philip H E; Carolan, Vikki A
2017-04-01
The analytical method outlined in this feasibility study has been used to show that trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)) can be detected and measured in exhaled breath condensate (EBC) samples. EBC samples and urine samples were collected from a cohort of 58 workers occupationally exposed to hexavalent chromium compounds and 22 unexposed volunteers (control group). Levels of Cr(III) and Cr(VI) were determined in EBC samples and total chromium levels were determined in urine samples. Pre and post working week samples for both EBC and urine were collected in tandem. Total chromium in urine samples was analysed by inductively coupled plasma mass spectrometry (ICP-MS). Analysis of Cr(III) and Cr(VI) in EBC samples used a hyphenated micro liquid chromatography (μLC) system coupled to an ICP-MS. Separation was achieved using an anion exchange micro-sized column. The results showed that the occupationally exposed workers had significantly higher levels of Cr(III) and Cr(VI) in their EBC samples than the control group, as well as higher levels of total chromium in their urine samples. However, for the exposed workers no significant difference was found between pre and post working week EBC samples for either Cr(III) or Cr(VI). This study has established that Cr(III) and Cr(VI) can simultaneously be detected and measured in 'real' EBC samples and will help in understanding inhalation exposure. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.
Chung, Angela; Hudson, John; McKay, Gordon
2009-06-01
The Royal Canadian Mounted Police Forensic Science and Identification Services was looking for a confirmatory method for lysergic acid diethylamide (LSD). As a result, an ultra-performance liquid chromatography-tandem mass spectrometry method was validated for the confirmation and quantitation of LSD, iso-LSD, N-demethyl-LSD (nor-LSD), and 2-oxo-3-hydroxy-LSD (O-H-LSD). Relative retention time and ion ratios were used as identification parameters. Limits of detection (LOD) in blood were 5 pg/mL for LSD and iso-LSD and 10 pg/mL for nor-LSD and O-H-LSD. In urine, the LOD was 10 pg/mL for all analytes. Limits of quantitation (LOQ) in blood and urine were 20 pg/mL for LSD and iso-LSD and 50 pg/mL for nor-LSD and O-H-LSD. The method was linear, accurate, and precise from 10 to 2000 pg/mL in blood and 20 to 2000 pg/mL in urine for LSD and iso-LSD and from 20 to 2000 pg/mL in blood and 50 to 2000 pg/mL in urine for nor-LSD and O-H-LSD with a coefficient of determination (R(2)) > or = 0.99. The method was applied to blinded biological control samples and biological samples taken from a suspected LSD user. This is the first reported detection of O-H-LSD in blood from a suspected LSD user.
Gambelunghe, Cristiana; Sommavilla, Marco; Rossi, Ruggero
2002-12-01
The concentrations of nandrolone metabolites, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) were analysed in urine samples of professional athletes doing intense physical activity and sedentary subjects to verify if there was endogenous production of nandrolone and if there was any link between physical effort and the urinary metabolites of the steroid. We collected 18 urine samples from professional footballers age range 20-30 years, all from the same team, and 18 urine samples from males not doing any physical activity, age range 20-30 years. Neither group used nandrolone. Qualitative and quantitative analyses of urinary nandrolone metabolites were carried out by GC/MS followed by GC/MS/MS to confirm positive samples. This technique has been demonstrated to be an excellent analytical approach for the determination of anabolic steroids at very low detection limits in complex matrices such as urine. In five urine samples from professional footballers traces of 19-NA were detected. No trace of 19-NA was found in the group of sedentary subjects and no trace of 19-NE was found in any urine sample. The absence of nandrolone metabolites in sedentary subjects supports the hypothesis that the presence of 19-NA and 19-NE could be linked to physical effort even though the origin is not yet clear. Copyright 2002 John Wiley & Sons, Ltd.
Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee
2016-09-01
The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.
Automated drug identification system
NASA Technical Reports Server (NTRS)
Campen, C. F., Jr.
1974-01-01
System speeds up analysis of blood and urine and is capable of identifying 100 commonly abused drugs. System includes computer that controls entire analytical process by ordering various steps in specific sequences. Computer processes data output and has readout of identified drugs.
Balacescu, Ovidiu; Petrut, Bogdan; Tudoran, Oana; Feflea, Dragos; Balacescu, Loredana; Anghel, Andrei; Sirbu, Ioan O; Seclaman, Edward; Marian, Catalin
2017-11-01
Prostate cancer (PCa) remains one of the leading causes of cancer-related deaths in men. Despite the tremendous progress in research over the years, a suitable minimally invasive PCa biomarker is yet to be discovered. The recent advances regarding the roles of microRNAs as biomarkers has allowed for their study in PCa as well, especially as blood-based markers. However, there are several studies that used urine as biological sample to evaluate microRNAs as biomarkers for PCa diagnosis, prognosis, and treatment response, which were reviewed herein. A high degree of inconsistency among reports has been observed, which could be due to several analytical aspects, starting with different urinary fractions used for analysis and continuing with the employment of various analytical platforms and methods of statistical analysis. However, a few microRNAs were found to be dysregulated in the urine of PCa patients, which alone or together with serum prostate-specific antigen seem to improve diagnostic power even in the gray zone of PCa. These results warrant further confirmation by larger prospective studies, preferably using a standardized protocol for analysis. WIREs RNA 2017, 8:e1438. doi: 10.1002/wrna.1438 For further resources related to this article, please visit the WIREs website. © 2017 Wiley Periodicals, Inc.
Richards, S L; Cawley, A T; Cavicchioli, R; Suann, C J; Pickford, R; Raftery, M J
2016-04-01
Over recent years threats to racing have expanded to include naturally occurring biological molecules, such as peptides and proteins, and their synthetic analogues. Traditionally, antibodies have been used to enable detection of these compounds as they allow purification and concentration of the analyte of interest. The rapid expansion of peptide-based therapeutics necessitates a similarly rapid development of suitable antibodies or other means of enrichment. Potential alternative enrichment strategies include the use of aptamers, which offer the significant advantage of chemical synthesis once the nucleic acid sequence is known. A method was developed for the enrichment, detection and quantitation of gonadotropin-releasing hormone (GnRH) in equine urine using aptamer-based enrichment and LC-MS/MS. The method achieved comparable limits of detection (1 pg/mL) and quantification (2.5 pg/mL) to previously published antibody-based enrichment methods. The intra- and inter-assay precision achieved was less than 10% at both 5 and 20 pg/mL, and displayed a working dynamic range of 2.5-100 pg/mL. Significant matrix enhancement (170 ± 8%) and low analytical recovery (29 ± 15%) was observed, although the use of an isotopically heavy labelled GnRH peptide, GnRH (Pro(13)C5,(15)N), as the internal standard provides compensation for these parameters. Within the current limits of detection GnRH was detectable up to 1h post administration in urine and identification of a urinary catabolite extended this detection window to 4h. Based on the results of this preliminary investigation we propose the use of aptamers as a viable alternative to antibodies in the enrichment of peptide targets from equine urine. Copyright © 2016 Elsevier B.V. All rights reserved.
Hsu, Wei-Yi; Chen, Ching-Ming; Tsai, Fuu-Jen; Lai, Chien-Chen
2013-05-01
Urinary homovanillic acid (HVA)/vanillylmandelic acid (VMA), orotic acid (OA), and homogentisic acid (HGA) are diagnostic biomarkers of neuroblastoma, ornithine carbamoyl transferase deficiency (OCTD), and alkaptonuria (AKU), respectively. In this study, a high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for simultaneous quantification of HVA, VMA, OA, and HGA in urine. After sample preparation, which involved only the dilution procedure, samples were quantified by LC-MS/MS. Full-scan MS/MS mode enabled the urinary markers to be quantified with a high degree of specificity and sensitivity. Rather than using a separate enzymatic method to normalize the concentration of creatinine in urine, we quantified the level of creatinine in urine in one LC-MS run. The limits of detection were 10 μg/l for HGA, 25 μg/l for HVA/VMA, and 50 μg/l for OA with a single-to-noise ratio of 3; the limits of quantification were 50 μg/l for HVA and HGA, 100 μg/l for VMA, and 250 μg/l for OA. The linear dynamic range for quantification of the analytes covered 2 to 3 orders of magnitude, depending on the analyte. The relative standard deviation of the developed LC-MS/MS method was less than 4% for the intra-day validation and 10% for the inter-day validation. The results show that our LC-MS/MS technique is a highly sensitive and rapid method for screening for biomarkers that are diagnostic of three metabolic diseases. Copyright © 2012 Elsevier B.V. All rights reserved.
Water recovery and management test support modeling for Space Station Freedom
NASA Technical Reports Server (NTRS)
Mohamadinejad, Habib; Bacskay, Allen S.
1990-01-01
The water-recovery and management (WRM) subsystem proposed for the Space Station Freedom program is outlined, and its computerized modeling and simulation based on a Computer Aided System Engineering and Analysis (CASE/A) program are discussed. A WRM test model consisting of a pretreated urine processing (TIMES), hygiene water processing (RO), RO brine processing using TIMES, and hygiene water storage is presented. Attention is drawn to such end-user equipment characteristics as the shower, dishwasher, clotheswasher, urine-collection facility, and handwash. The transient behavior of pretreated-urine, RO waste-hygiene, and RO brine tanks is assessed, as well as the total input/output to or from the system. The model is considered to be beneficial for pretest analytical predictions as a program cost-saving feature.
Silva, Catarina; Cavaco, Carina; Perestrelo, Rosa; Pereira, Jorge; Câmara, José S.
2014-01-01
For a long time, sample preparation was unrecognized as a critical issue in the analytical methodology, thus limiting the performance that could be achieved. However, the improvement of microextraction techniques, particularly microextraction by packed sorbent (MEPS) and solid-phase microextraction (SPME), completely modified this scenario by introducing unprecedented control over this process. Urine is a biological fluid that is very interesting for metabolomics studies, allowing human health and disease characterization in a minimally invasive form. In this manuscript, we will critically review the most relevant and promising works in this field, highlighting how the metabolomic profiling of urine can be an extremely valuable tool for the early diagnosis of highly prevalent diseases, such as cardiovascular, oncologic and neurodegenerative ones. PMID:24958388
Resonance light scattering determination of 6-mercaptopurine coupled with HPLC technique
NASA Astrophysics Data System (ADS)
Li, Ai Ping; Peng, Jing Dong; Zhou, MingQiong; Zhang, Jin
2016-02-01
A simple, fast, costless, sensitive and selective method of resonance light scattering coupled with HPLC was established for the determination of 6-mercaptopurine in human urine sample. In a Britton-Robinson buffer solution of pH 5.5, the formation of coordination complex between 6-mercaptopurine and metal palladium (II) led to enhance the RLS intensity of the system. The RLS signal was detected by fluorescence detector at λex = λem = 315 nm. The analytical parameters were provided by the coupled system, the linear of 6-mercaptopurine response from 0.0615 to 2.40 μg L- 1 and the limit of detection (S/N = 3) was 0.05 μg L- 1. The presented method has been applied to determine 6-mercaptopurine in human urine samples which obtained satisfactory results. Moreover, the reaction mechanism and possible reasons for enhancement of RLS were fully discussed.
Resonance light scattering determination of 6-mercaptopurine coupled with HPLC technique.
Li, Ai Ping; Peng, Jing Dong; Zhou, MingQiong; Zhang, Jin
2016-02-05
A simple, fast, costless, sensitive and selective method of resonance light scattering coupled with HPLC was established for the determination of 6-mercaptopurine in human urine sample. In a Britton-Robinson buffer solution of pH5.5, the formation of coordination complex between 6-mercaptopurine and metal palladium (II) led to enhance the RLS intensity of the system. The RLS signal was detected by fluorescence detector at λ(ex)=λ(em)=315 nm. The analytical parameters were provided by the coupled system, the linear of 6-mercaptopurine response from 0.0615 to 2.40 μg L(-1) and the limit of detection (S/N=3) was 0.05 μg L(-1). The presented method has been applied to determine 6-mercaptopurine in human urine samples which obtained satisfactory results. Moreover, the reaction mechanism and possible reasons for enhancement of RLS were fully discussed. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Suaniti, Ni Made; Manurung, Manuntun
2016-03-01
Gas Chromatography-Mass Spectrometry is used to separate two and more compounds and identify fragment ion specific of biomarker ethanol such as palmitic acid ethyl ester (PAEE), as one of the fatty acid ethyl esters as early detection through conyugated reaction. This study aims to calibrate ethyl palmitate and develop analysis with oleate acid. This methode can be used analysis ethanol and its chemistry biomarker in ethanol sub-acute consumption as analytical forensic toxicology. The result show that ethanol level in urine rats Wistar were 9.21 and decreased 6.59 ppm after 48 hours consumption. Calibration curve of ethyl palmitate was y = 0.2035 x + 1.0465 and R2 = 0.9886. Resolution between ethyl palmitate and oleate were >1.5 as good separation with fragment ion specific was 88 and the retention time was 18 minutes.
Development of a method which discriminates between endogenous and exogenous beta-boldenone.
Blokland, M H; van Rossum, H J; Sterk, S S; van Ginkel, L A; Stephany, R W
2007-03-14
One potential explanation for the presence of beta-boldenone in calf urine is contamination of the sample with feces containing beta-boldenone. It has been demonstrated that after oral and intramuscular administration of beta-boldenone esters, several metabolites are formed and excreted in urine. One of the (minor) metabolites is 6beta-hydroxy-17alpha-boldenone. This paper describes an analytical method that can discriminate between unconjugated boldenone, its glucuronide- and sulphate-conjugates, 6beta-hydroxy-17alpha/beta-boldenone and coprostanol, a marker for fecal contamination. The method was applied to all samples suspected to contain boldenone within the Dutch National Residue Control Plan. Approximately 10,000 samples of urine were screened (LC-MS) in 2004-2005 by VWA-East, one of the official Dutch control laboratories, from which 261 samples were suspected to contain boldenone. These samples were all analyzed for their conjugation state, 6beta-hydroxy-17alpha/beta-boldenone and for the presence of coprostanol. Alfa-boldenone, the major metabolite in bovine urine after boldenone-ester administration, was found in a large number of these samples. The presence of alpha-boldenone was proven also to be a result of fecal contamination. None of the samples tested contained residues of the metabolite 6beta-hydroxy-17alpha/beta-boldenone. Not finding this metabolite indicates that the origin of alpha-boldenone-conjugates is endogenous. The results confirm that the presence of unconjugated beta-boldenone and alpha-boldenone conjugates next to alpha-boldenone are no indicators for illegal administration of boldenone-esters. No indications were obtained that conjugated beta-boldenone can be of endogenous origin.
Simplified urinary immunoassay for 2,4-D: validation and exposure assessment.
Lyubimov, A V; Garry, V F; Carlson, R E; Barr, D B; Baker, S E
2000-08-01
Urinary monitoring of exposed workers by either analytic chemical methods or radioimmunoassay suggests that urinary levels of 2,4-dichlorophenoxyacetic acid (2,4-D) exceeding 30 ppb are indicative of occupational exposure. However, the current methods do not lend themselves to clinical laboratory use in the rural medical setting. The major goal of this project was to provide medical practitioners who care for members of the agricultural community with a cost-efficient way to conduct exposure assessment. This project used a direct 2,4-D enzyme immunoassay (EIA) and measurement of the ratio between 2,4-D-spiked and non-spiked samples of the same urine to quantify 2,4-D levels. This simplified approach minimizes the effects of non-specific interfering substances in urine and eliminates the need for sample extraction and clean-up. Possible urine co-contaminants (2,4-dichlorophenol and 2,5-dichlorophenol) do not significantly interfere with this immunoassay. Twenty-two forest pesticide applicators who apply and use chlorophenoxy herbicides in their work and 14 comparable control subjects were studied to validate the assay in the occupational setting. Coded urine specimens were examined for levels of 2,4-D by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and compared with immunoassay results from the same specimens. A correlation coefficient of r = 0.982 with a P value of .0001 for a plot of HPLC-MS/MS versus immunoassay demonstrated that the results from these methods were comparable over urinary dose levels ranging from not detectable (<19 ppb) to 1700 ppb 2,4-D, as determined by immunoassay.
Kift, Rebecca L; Messenger, Michael P; Wind, Tobias C; Hepburn, Sophie; Wilson, Michelle; Thompson, Douglas; Smith, Matthew Welberry; Sturgeon, Catharine; Lewington, Andrew J; Selby, Peter J; Banks, Rosamonde E
2013-05-01
Neutrophil gelatinase-associated lipocalin (NGAL) is a promising biomarker for acute kidney injury that is beginning to be used in clinical practice in addition to research studies. The current study describes an independent validation and comparison of five commercially available NGAL assays, focusing on urine samples. This is an essential step in the translation of this marker to clinical use in terms of allowing valid inter-study comparison and generation of robust results. Two CE (Conformité Européenne)-marked assays, the NGAL Test (BioPorto) on Siemens ADVIA(®) 1800 and the ARCHITECT Urine NGAL assay on i2000SR (Abbott Laboratories), and three research-use-only (RUO) ELISAs (R&D Systems, Hycult and BioPorto) were evaluated. Imprecision, parallelism, recovery, selectivity, limit of quantitation (LOQ), vulnerability to interference and hook effect were assessed and inter-assay agreement was determined using 68 urine samples from patients with various renal diseases and healthy controls. The Abbott and R&D Systems assays demonstrated satisfactory performance for all parameters tested. However for the other three assays evaluated, problems were identified with LOQ (BioPorto/ADVIA(®)), parallelism (BioPorto ELISA) or several parameters (Hycult). Between-method agreement varied with the Hycult assay in particular being markedly different and highlighting issues with standardization and form of NGAL measured. Variability exists between the five NGAL assays in terms of their performance and this should be taken into account when interpreting results from the various clinical or research studies measuring urinary NGAL.
Wójtowicz, Marzena; Jarek, Anna; Chajewska, Katarzyna; Turek-Lepa, Ewa; Kwiatkowska, Dorota
2015-11-10
The quantitative analysis of a new designer doping agent, 2-ethylamino-1-phenylbutane (EAPB) and its metabolite, 2-amino-1-phenylbutane (APB) in urine samples, and the determination of EAPB in dietary supplement samples, have been presented. The main purpose of the present study was to develop simple and reliable gas chromatography-mass spectrometry method (GC-MS) for excretion study following a single oral administration of dietary supplements containing EAPB. Three analytical methods for the determination of EAPB in urine and supplement samples, and APB in urine samples using the GC-MS system, have been validated. The method of the determination of EAPB in supplement samples was applied to analyze seventeen dietary supplements, CRAZE and DETONATE. Two other methods were used to determine the urinary excretion profile of EAPB and APB in the case of three healthy volunteers and, on further investigation, it was applied to the anti-doping control in sport. Quantification was obtained on the basis of the ions at m/z 86, 58 and 169, monitored for EAPB, APB and diphenylamine (used as an internal standard), respectively. The limits of detection and quantification were 2.4 and 7.3μg/g for EAPB in the case of supplement analysis, 2.9 and 8.8ng/mL for EAPB in the case of urine analysis, and 3.2 and 9.7ng/mL for APB. The other validation parameters as linearity, precision and trueness have been also investigated with the acceptable results. The extraction yield of all presented methods was above 69%. EAPB was detected in fourteen analyzed supplements (not included EAPB in their labels) and its content varied between 1.8 and 16.1mg/g. Following oral administration of three supplements with EAPB to one male and two female volunteers, the parent compound of EAPB and its metabolite were monitored and the excretion parameters as the maximum concentration of the analyte in urine (2.2-4.2μg/mL for EAPB; 1.1-5.1μg/mL for APB) and the time for the maximum height of the excretion peak (2-8h and 22h in one case for EAPB; 20-22h and 4h in one case for APB) have been indicated. EAPB and APB were detected at the level above 50ng/mL (50% of the minimum required performance level for stimulants in the anti-doping control in-competition in sport) in the urine up to 46-106h and 58-120h, respectively. Additionally, the result of the anti-doping control during swimming competition of one athlete, whose urine sample was analyzed for stimulants and narcotics, has been presented. The qualitative and quantitative analyses of new designer agents in urine samples and the excretion studies of these substances are of a great importance in the anti-doping control in sport. Moreover, the presentation of detection examples of these agents in supplements that haven't got included an information about them in the labeling, make athletes (and other supplement customers) more and more aware of the risk of the supplement use and possible health and doping consequences. Copyright © 2015 Elsevier B.V. All rights reserved.
Gu, Hui-Wen; Wu, Hai-Long; Yin, Xiao-Li; Li, Yong; Liu, Ya-Juan; Xia, Hui; Zhang, Shu-Rong; Jin, Yi-Feng; Sun, Xiao-Dong; Yu, Ru-Qin; Yang, Peng-Yuan; Lu, Hao-Jie
2014-10-27
β-blockers are the first-line therapeutic agents for treating cardiovascular diseases and also a class of prohibited substances in athletic competitions. In this work, a smart strategy that combines three-way liquid chromatography-mass spectrometry (LC-MS) data with second-order calibration method based on alternating trilinear decomposition (ATLD) algorithm was developed for simultaneous determination of ten β-blockers in human urine and plasma samples. This flexible strategy proved to be a useful tool to solve the problems of overlapped peaks and uncalibrated interferences encountered in quantitative LC-MS, and made the multi-targeted interference-free qualitative and quantitative analysis of β-blockers in complex matrices possible. The limits of detection were in the range of 2.0×10(-5)-6.2×10(-3) μg mL(-1), and the average recoveries were between 90 and 110% with standard deviations and average relative prediction errors less than 10%, indicating that the strategy could provide satisfactory prediction results for ten β-blockers in human urine and plasma samples only using liquid chromatography hyphenated single-quadrupole mass spectrometer in full scan mode. To further confirm the feasibility and reliability of the proposed method, the same batch samples were analyzed by multiple reaction monitoring (MRM) method. T-test demonstrated that there are no significant differences between the prediction results of the two methods. Considering the advantages of fast, low-cost, high sensitivity, and no need of complicated chromatographic and tandem mass spectrometric conditions optimization, the proposed strategy is expected to be extended as an attractive alternative method to quantify analyte(s) of interest in complex systems such as cells, biological fluids, food, environment, pharmaceuticals and other complex samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Molecularly imprinted polymers for separation of various sugars from human urine.
Okutucu, Burcu; Onal, Seçil
2011-12-15
Molecularly imprinted polymers were the new, simple and unexpensive materials that can be used in several clinical applications. Phenylboronic acid has been frequently used as functional monomer for the covalent imprinting of diols. In this study, the phenylboronic acid esters of fructose, galactose, glucose and raffinose were synthesized and then used as template analytes. The adsorption capacities of fructose, galactose and glucose-phenylboronic acid imprinted polymers were 75, 10 and 30%, respectively. The batch rebinding studies and Scatchard analysis were done for all sugar imprinted polymer. Glucose is one of the mostly found sugar in the urine. The glucose:phenylboronic acid imprinted polymer was used for the analysis of glucose, fructose, galactose, sucrose, maltose, lactose and raffinose in spiked urine. The selectivity of glucose:phenylboronic acid imprinted polymer to urine monosaccharides was found as nearly 45-55% and to di- and polysaccharides was found as 30-35%, respectively. Copyright © 2011 Elsevier B.V. All rights reserved.
SPE-GC/FTD determination of N-methyl-2-pyrrolidone and its metabolites in urine.
Kubota, Ryuichi; Endo, Yoko; Takeuchi, Akito; Inoue, Yoshinori; Ogata, Hiroko; Ogawa, Masanori; Nakagawa, Tomoo; Onda, Nobuhiko; Endo, Ginji
2007-07-01
An analytical method using a combination of solid-phase extraction (SPE) and gas chromatography with a flame thermionic detector (GC/FTD) was developed for determination of N-methyl-2-pyrrolidone (NMP), N-methylsuccinimide (MSI), and 2-hydroxy-N-methylsuccinimide (2-HMSI) in human urine. The SPE cartridge of poly(divinylbenzene/hydroxymethacrylate) used was directly loaded with urine sample, followed by elution with methyl isobutyl ketone (MIBK) and subsequent centrifugation, and the supernatant was injected into the capillary GC using a DB1701. This method allowed efficient separation of NMP, MSI, and 2-HMSI, which were nearly free of interference by other GC peaks arising from urine. Recoveries of NMP, MSI, and 2-HMSI from the SPE cartridge were about 98, 101, and 67%, respectively, with limits of detection of 0.04, 0.02, and 0.06 mg/L, respectively, which met the regulatory requirements. The present method was used for assay in biological monitoring of workers exposed to NMP in their occupational environment.
Quantitative electrochemical metalloimmunoassay for TFF3 in urine using a paper analytical device.
DeGregory, Paul R; Tsai, Yi-Ju; Scida, Karen; Richards, Ian; Crooks, Richard M
2016-03-07
We report a paper-based assay platform for the detection of the kidney disease marker Trefoil Factor 3 (TFF3) in human urine. The sensor is based on a quantitative metalloimmunoassay that can determine TFF3 concentrations via electrochemical detection of environmentally stable silver nanoparticle (AgNP) labels attached to magnetic microbeads via a TFF3 immunosandwich. The paper electroanalytical device incorporates two preconcentration steps that make it possible to detect concentrations of TFF3 in human urine at the low end of the target TFF3 concentration range (0.03-7.0 μg mL(-1)). Importantly, the paper device provides a level of accuracy for TFF3 determination in human urine equivalent to that of a commercial kit. The paper sensor has a dynamic range of ∼2.5 orders of magnitude, only requires a simple, one-step incubation protocol, and is fast, requiring only 10 min to complete. The cost of the materials at the prototypic laboratory scale, excluding reagents, is just US$0.42.
Unceta, Nora; Gómez-Caballero, Alberto; García, Deiene; Díaz, Goretti; Guerreiro, Antonio; Piletsky, Sergey; Goicolea, M Aránzazu; Barrio, Ramón J
2013-11-15
This paper reports the application of a chiral imprinted polymer (CIP)-coated stir bar for the selective extraction of (+)-(S)-citalopram (SCIT) and its main metabolites, (+)-(S)-desmethylcitalopram (SDCIT) and (+)-(S)-didesmethylcitalopram (SDDCIT), from urine samples. The developed device has been demonstrated to be capable of selectively extracting the three target analytes from urine samples without saturating the imprinted sites. A CIP-coated stir bar sorptive extraction procedure (CIP-SBSE) is proposed for the isolation of SCIT, SDCIT and SDDCIT followed by their subsequent analysis using liquid chromatography ion trap mass spectrometry (LC-ITMS). Deuterated SCIT-d6 was used as an internal standard. The method was validated using a standard procedure, which revealed that a quantification of 5 ng mL(-1) was obtained in urine samples and that the accuracy and precision were within the established values while no matrix effect was observed. Copyright © 2013 Elsevier B.V. All rights reserved.
Teixeira, Helena; Verstraete, Alain; Proença, Paula; Corte-Real, Francisco; Monsanto, Paula; Vieira, Duarte Nuno
2007-08-06
A fully validated, sensitive and specific method for the extraction and quantification of Delta(9)-tetrahydrocannabinol (THC) and 11-nor-9-carboxy-Delta(9)-THC (THC-COOH) and for the detection of 11-hydroxy-Delta(9)-THC (11-OH THC) in oral fluid, urine and whole blood is presented. Solid-phase extraction and liquid chromatography-mass spectrometry (LC-MS) technique were used, with electrospray ionization. Three ions were monitored for THC and THC-COOH and two for 11-OH THC. The compounds were quantified by selected ion recording of m/z 315.31, 329.18 and 343.16 for THC, 11-OH THC and THC-COOH, respectively, and m/z 318.27 and 346.26 for the deuterated internal standards, THC-d(3) and THC-COOH-d(3), respectively. The method proved to be precise for THC and THC-COOH both in terms of intra-day and inter-day analysis, with intra-day coefficients of variation (CV) less than 6.3, 6.6 and 6.5% for THC in saliva, urine and blood, respectively, and 6.8 and 7.7% for THC-COOH in urine and blood, respectively. Day-to-day CVs were less than 3.5, 4.9 and 11.3% for THC in saliva, urine and blood, respectively, and 6.2 and 6.4% for THC-COOH in urine and blood, respectively. Limits of detection (LOD) were 2 ng/mL for THC in oral fluid and 0.5 ng/mL for THC and THC-COOH and 20 ng/mL for 11-OH THC, in urine and blood. Calibration curves showed a linear relationship for THC and THC-COOH in all samples (r(2)>0.999) within the range investigated. The procedure presented here has high specificity, selectivity and sensitivity. It can be regarded as an alternative method to GC-MS for the confirmation of positive immunoassay test results, and can be used as a suitable analytical tool for the quantification of THC and THC-COOH in oral fluid, urine and/or blood samples.
Morton, Jackie; Tan, Emma; Leese, Elizabeth; Cocker, John
2014-12-01
levels for 61 elements were established in urine samples collected from 132 occupationally unexposed UK adults. In this study all elements were determined by inductively coupled plasma-mass spectrometry, but methods were 'tailored' to the elements; in total six analytical methods were undertaken. For the first time in a UK population 95th percentile values are reported for 19 elements for which there is no available comparison. Repeat urine samples were collected from some individuals and mixed effects modelling was carried out on the data to give an estimation of variation both between individuals and within the same individual. The mixed effects modelling was undertaken on 31 of the 61 elements for which there were more than two thirds of data above the LOQ and variations of between and within individuals are reported. The analysis found that creatinine adjustment of analyte concentrations was found to be beneficial for 22 of the 31 elements and that smokers were found to exhibit significantly higher cadmium but lower boron than non-smokers. For most elements, the data compare well with other published data but higher concentrations were observed in this study for urinary lead, chromium, vanadium and tungsten. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Schistosoma real-time PCR as diagnostic tool for international travellers and migrants.
Cnops, Lieselotte; Tannich, Egbert; Polman, Katja; Clerinx, Jan; Van Esbroeck, Marjan
2012-10-01
To evaluate the use of a genus-specific PCR that combines high sensitivity with the detection of different Schistosoma species for diagnosis in international travellers and migrants in comparison to standard microscopy. The genus-specific real-time PCR was developed to target the 28S ribosomal RNA gene of the major human Schistosoma species. It was validated for analytical specificity and reproducibility and demonstrated an analytical sensitivity of 0.2 eggs per gram of faeces. Its diagnostic performance was further evaluated on 152 faecal, 32 urine and 38 serum samples from patients presenting at the outpatient clinic of the Institute of Tropical Medicine in Antwerp (Belgium). We detected Schistosoma DNA in 76 faecal (50.0%) and five urine (15.6%) samples of which, respectively, nine and one were not detected by standard microscopy. Only two of the 38 serum samples of patients with confirmed schistosomiasis were positive with the presently developed PCR. Sequence analysis on positive faecal samples allowed identification of the Schistosoma species complex. The real-time PCR is highly sensitive and may offer added value in diagnosing imported schistosomiasis. The genus-specific PCR can detect all schistosome species that are infectious to humans and performs very well with faeces and urine, but not in serum. © 2012 Blackwell Publishing Ltd.
Determination of opiates and cocaine in urine by high pH mobile phase reversed phase UPLC-MS/MS.
Berg, Thomas; Lundanes, Elsa; Christophersen, Asbjørg S; Strand, Dag Helge
2009-02-01
A fast and selective ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the determination of opiates (morphine, codeine, 6-monoacetylmorphine (6-MAM), pholcodine, oxycodone, ethylmorphine), cocaine and benzoylecgonine in urine has been developed and validated. Sample preparation was performed by solid phase extraction (SPE) on a mixed mode cation exchange (MCX) cartridge. For optimized chromatographic performance with repeatable retention times, narrow and symmetrical peaks, and focusing of all analytes at the column inlet at gradient start, a basic mobile phase consisting of 5mM ammonium bicarbonate, pH 10.2, and methanol (MeOH) was chosen. Positive electrospray ionization (ESI(+)) MS/MS detection was performed with a minimum of two multiple reaction monitoring (MRM) transitions for each analyte. Deuterium labelled-internal standards were used for six of the analytes. Between-assay retention time repeatabilities (n=10 series, 225 injections in total) had relative standard deviation (RSD) values within 0.1-0.6%. Limit of detection (LOD) and limit of quantification (LOQ) values were in the range 0.003-0.05 microM (0.001-0.02 microg/mL) and 0.01-0.16 microM (0.003-0.06 microg/mL), respectively. The RSD values of the between-assay repeatabilities of concentrations were
Poklis, Justin L.; Nanco, Carol R.; Troendle, Michelle M.; Wolf, Carl E.; Poklis, Alphonse
2014-01-01
We present a case of 4-bromo-2,5-dimethoxy-N-[(2-methoxyphenyl)methyl]-benzeneethanamine (25B-NBOMe), an N-benzyl phenethylamines derivative, intoxication and a high performance liquid chromatography with tandem mass spectrometry (HPLC-MS/MS) method for detection and quantification of 25B-NBOMe.A 19-year-old male was found unresponsive with generalized grand mal seizure activity. On the second day of hospitalization, a friend admitted that the patient used ‘some unknown drug’ called 25B. Serum and urine collected were sent to the Virginia Commonwealth University Medical Center Toxicology Laboratory for analysis. An HPLC-MS/MS method for the identification and quantificationof 25B-NBOMe using 2-(2,5-dimethoxyphenyl)-N-(2-methoxybenzyl) ethanamine (25H-NBOMe)as the internal standard (ISTD)was developed. As this is a novel, single-case presentation, an assay validation was performed prior to testing to ensure the reliability of the analytical results. The serum and urine specimens were determined to contain 180 pg/ml and1900 pg/ml of 25B-NBOMe, respectively. PMID:24000244
An approach to the systematic analysis of urinary steroids
Menini, E.; Norymberski, J. K.
1965-01-01
1. Human urine, its extracts, extracts of urine pretreated with enzyme preparations containing β-glucuronidase and steroid sulphatase or β-glucuronidase alone, and products derived from the specific solvolysis of urinary steroid sulphates, were submitted to the following sequence of operations: reduction with borohydride; oxidation with a glycol-cleaving agent (bismuthate or periodate); separation of the products into ketones and others; oxidation of each fraction with tert.-butyl chromate, resolution of the end products by means of paper chromatography or gas–liquid chromatography or both. 2. Qualitative experiments indicated the kind of information the method and some of its modifications can provide. Quantitative experiments were restricted to the direct treatment of urine by the basic procedure outlined. It was partly shown and partly argued that the quantitative results were probably as informative about the composition of the major neutral urinary steroids (and certainly about their presumptive secretory precursors) as those obtained by a number of established analytical procedures. 3. A possible extension of the scope of the reported method was indicated. 4. A simple technique was introduced for the quantitative deposition of a solid sample on to a gas–liquid-chromatographic column. PMID:14333557
Pettersson Bergstrand, Madeleine; Meyer, Markus R; Beck, Olof; Helander, Anders
2018-03-01
Over the past ~8 years, hundreds of unregulated new psychoactive substances (NPS) of various chemical categories have been introduced as recreational drugs through mainly open online trade. This study was performed to further investigate the human metabolic pattern of the NPS, or designer benzodiazepines flubromazolam and pyrazolam, and to propose analytical targets for urine drug testing of these substances. The urine samples originated from patient samples confirmed by liquid chromatography-high-resolution tandem mass spectrometry (LC-HRMS/MS) analysis to contain flubromazolam or pyrazolam. The LC-HRMS/MS system consisted of a YMC-UltraHT Hydrosphere C18 column (YMC, Dinslaken, Germany) coupled to a Thermo Scientific (Waltham, MA, USA) Q Exactive Orbitrap MS operating in positive electrospray mode. The samples were analyzed both with and without enzymatic hydrolysis using β-glucuronidase. Besides the parent compounds, the main urinary excretion products were parent glucuronides, mono-hydroxy metabolites, and mono-hydroxy glucuronides. In samples prepared without hydrolysis, the most common flubromazolam metabolites were 1 of the mono-hydroxy glucuronides and 1 of the parent glucuronides. For pyrazolam, a parent glucuronide was the most common metabolite. These 3 metabolites were detected in all samples and were considered the primary targets for urine drug testing and confirmation of intake. After enzymatic hydrolysis of the urine samples, a 2-19-fold increase in the concentration of flubromazolam was found, highlighting the value of hydrolysis for this analyte. With hydrolysis, the flubromazolam hydroxy metabolites should be used as target metabolites. Copyright © 2017 John Wiley & Sons, Ltd.
Yoshida, Toshiaki
2017-10-01
Pyrethroids are widely being used as household insecticides or mothproof repellents. An analytical method is described for determination of urinary metabolites as biomarkers for monitoring exposure to the pyrethroids. In total, 11 urinary metabolites, 3-(2-carboxyprop-1-enyl)-2,2-dimethylcyclopropanecarboxylic acid, 3-(2-chloro-3,3,3-trifluoroprop-1-enyl)-2,2-dimethylcyclopropanecarboxylic acid, 3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylic acid, 2,2-dimethyl-3-(2-methylprop-1-enyl)cyclopropanecarboxylic acid, 4-fluoro-3-phenoxybenzoic acid, 4-methoxymethyl-2,3,5,6-tetrafluorobenzly alcohol, 2-methyl-3-phenylbenzoic acid, 4-methyl-2,3,5,6-tetrafluorobenzyl alcohol, 3-phenoxybenzoic acid, 2,3,5,6-tetrafluorobenzoic acid and 2,2,3,3-tetramethylcyclopropanecarboxylic acid, were enzymatically hydrolyzed and extracted with toluene. After transformation to their tert-butyldimethylsilyl or trimethylsilyl derivatives, they were analyzed by gas chromatography/mass spectrometry in electron impact ionization mode. The calibration curves for the metabolite were linear over the concentration range of 0-30 μg/L in urine. They could be determined accurately and precisely (detection limits: 0.01-0.12 μg/L, quantification limits: 0.04-0.41 μg/L). The urine samples collected could be stored for up to 1 month at -20°C in a freezer. The proposed method was applied to determine urine samples from several health volunteers. The method was considered to be available for monitoring pyrethroid exposure in the general population. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
McGuffey, James E.; Wei, Binnian; Bernert, John T.; Morrow, John C.; Xia, Baoyun; Wang, Lanqing; Blount, Benjamin C.
2014-01-01
Tobacco use is a major contributor to premature morbidity and mortality. The measurement of nicotine and its metabolites in urine is a valuable tool for evaluating nicotine exposure and for nicotine metabolic profiling—i.e., metabolite ratios. In addition, the minor tobacco alkaloids—anabasine and anatabine—can be useful for monitoring compliance in smoking cessation programs that use nicotine replacement therapy. Because of an increasing demand for the measurement of urinary nicotine metabolites, we developed a rapid, low-cost method that uses isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) for simultaneously quantifying nicotine, six nicotine metabolites, and two minor tobacco alkaloids in smokers' urine. This method enzymatically hydrolyzes conjugated nicotine (primarily glucuronides) and its metabolites. We then use acetone pretreatment to precipitate matrix components (endogenous proteins, salts, phospholipids, and exogenous enzyme) that may interfere with LC-MS/MS analysis. Subsequently, analytes (nicotine, cotinine, hydroxycotinine, norcotinine, nornicotine, cotinine N-oxide, nicotine 1′-N-oxide, anatabine, and anabasine) are chromatographically resolved within a cycle time of 13.5 minutes. The optimized assay produces linear responses across the analyte concentrations typically found in urine collected from daily smokers. Because matrix ion suppression may influence accuracy, we include a discussion of conventions employed in this procedure to minimize matrix interferences. Simplicity, low cost, low maintenance combined with high mean metabolite recovery (76–99%), specificity, accuracy (0–10% bias) and reproducibility (2–9% C.V.) make this method ideal for large high through-put studies. PMID:25013964
He, Gaoli; Guo, Beining; Yu, Jicheng; Zhang, Jing; Wu, Xiaojie; Cao, Guoying; Shi, Yaoguo; Tsai, Cheng-Yuan
2015-05-01
Three methods were developed and validated for determination of nemonoxacin in human feces and its major metabolite, nemonoxacin acyl-β- d-glucuronide, in human urine and feces. Nemonoxacin was extracted by liquid-liquid extraction in feces homogenate samples and nemonoxacin acyl-β- d-glucuronide by a solid-phase extraction procedure for pretreatment of both urine and feces homogenate sample. Separation was performed on a C18 reversed-phase column under isocratic elution with the mobile phase consisting of acetonitrile and 0.1% formic acid. Both analytes were determined by liquid chromatography-tandem mass spectrometry with positive electrospray ionization in selected reaction monitoring mode and gatifloxacin as the internal standard. The lower limit of quantitation (LLOQ) of nemonoxacin in feces was 0.12 µg/g and the calibration curve was linear in the concentration range of 0.12-48.00 µg/g. The LLOQ of the metabolite was 0.0010 µg/mL and 0.03 µg/g in urine and feces matrices, while the linear range was 0.0010-0.2000 µg/mL and 0.03-3.00 µg/g, respectively. Validation included selectivity, accuracy, precision, linearity, recovery, matrix effect, carryover, dilution integrity and stability, indicating that the methods can quantify the corresponding analytes with excellent reliability. The validated methods were successfully applied to an absolute bioavailability clinical study of nemonoxacin malate capsule. Copyright © 2014 John Wiley & Sons, Ltd.
Impact of enzymatic and alkaline hydrolysis on CBD concentration in urine
Bergamaschi, Mateus M.; Barnes, Allan; Queiroz, Regina H. C.; Hurd, Yasmin L.
2013-01-01
A sensitive and specific analytical method for cannabidiol (CBD) in urine was needed to define urinary CBD pharmacokinetics after controlled CBD administration, and to confirm compliance with CBD medications including Sativex—a cannabis plant extract containing 1:1 Δ9-tetrahydrocannabinol (THC) and CBD. Non-psychoactive CBD has a wide range of therapeutic applications and may also influence psychotropic smoked cannabis effects. Few methods exist for the quantification of CBD excretion in urine, and no data are available for phase II metabolism of CBD to CBD-glucuronide or CBD-sulfate. We optimized the hydrolysis of CBD-glucuronide and/or -sulfate, and developed and validated a GC-MS method for urinary CBD quantification. Solid-phase extraction isolated and concentrated analytes prior to GC-MS. Method validation included overnight hydrolysis (16 h) at 37 °C with 2,500 units β-glucuronidase from Red Abalone. Calibration curves were fit by linear least squares regression with 1/x2 weighting with linear ranges (r2>0.990) of 2.5–100 ng/mL for non-hydrolyzed CBD and 2.5–500 ng/mL for enzyme-hydrolyzed CBD. Bias was 88.7–105.3 %, imprecision 1.4–6.4 % CV and extraction efficiency 82.5–92.7 % (no hydrolysis) and 34.3–47.0 % (enzyme hydrolysis). Enzyme-hydrolyzed urine specimens exhibited more than a 250-fold CBD concentration increase compared to alkaline and non-hydrolyzed specimens. This method can be applied for urinary CBD quantification and further pharmacokinetics characterization following controlled CBD administration. PMID:23494274
Wijemanne, Nimanthi; Soysa, Preethi; Wijesundara, Sulochana; Perera, Hemamali
2018-01-01
Uric acid and hypoxanthine are produced in the catabolism of purine. Abnormal urinary levels of these products are associated with many diseases and therefore it is necessary to have a simple and rapid method to detect them. Hence, we report a simple reverse phase high performance liquid chromatography (HPLC/UV) technique, developed and validated for simultaneous analysis of uric acid, hypoxanthine, and creatinine in human urine. Urine was diluted appropriately and eluted with C-18 column 100 mm × 4.6 mm with a C-18 precolumn 25 mm × 4.6 mm in series. Potassium phosphate buffer (20 mM, pH 7.25) at a flow rate of 0.40 mL/min was employed as the solvent and peaks were detected at 235 nm. Tyrosine was used as the internal standard. The experimental conditions offered a good separation of analytes without interference of endogenous substances. The calibration curves were linear for all test compounds with a regression coefficient, r 2 > 0.99. Uric acid, creatinine, tyrosine, and hypoxanthine were eluted at 5.2, 6.1, 7.2, and 8.3 min, respectively. Intraday and interday variability were less than 4.6% for all the analytes investigated and the recovery ranged from 98 to 102%. The proposed HPLC procedure is a simple, rapid, and low cost method with high accuracy with minimum use of organic solvents. This method was successfully applied for the determination of creatinine, hypoxanthine, and uric acid in human urine.
Hydroxytyrosol disposition in humans.
Miro-Casas, Elisabet; Covas, Maria-Isabel; Farre, Magi; Fito, Montserrat; Ortuño, Jordi; Weinbrenner, Tanja; Roset, Pere; de la Torre, Rafael
2003-06-01
Animal and in vitro studies suggest that phenolic compounds in virgin olive oil are effective antioxidants. In animal and in vitro studies, hydroxytyrosol and its metabolites have been shown to be strong antioxidants. One of the prerequisites to assess their in vivo physiologic significance is to determine their presence in human plasma. We developed an analytical method for both hydroxytyrosol and 3-O-methyl-hydroxytyrosol in plasma. The administered dose of phenolic compounds was estimated from methanolic extracts of virgin olive oil after subjecting them to different hydrolytic treatments. Plasma and urine samples were collected from 0 to 12 h before and after 25 mL of virgin olive oil intake, a dose close to that used as daily intake in Mediterranean countries. Samples were analyzed by capillary gas chromatography-mass spectrometry before and after being subjected to acidic and enzymatic hydrolytic treatments. Calibration curves were linear (r >0.99). Analytical recoveries were 42-60%. Limits of quantification were <1.5 mg/L. Plasma hydroxytyrosol and 3-O-methyl-hydroxytyrosol increased as a response to virgin olive oil administration, reaching maximum concentrations at 32 and 53 min, respectively (P <0.001 for quadratic trend). The estimated hydroxytyrosol elimination half-life was 2.43 h. Free forms of these phenolic compounds were not detected in plasma samples. The proposed analytical method permits quantification of hydroxytyrosol and 3-O-methyl-hydroxytyrosol in plasma after real-life doses of virgin olive oil. From our results, approximately 98% of hydroxytyrosol appears to be present in plasma and urine in conjugated forms, mainly glucuronoconjugates, suggesting extensive first-pass intestinal/hepatic metabolism of the ingested hydroxytyrosol.
Yao, Yong; Zhang, Chunsun
2016-10-01
A novel screen-printed microfluidic paper-based analytical device with all-carbon electrode-enabled electrochemical assay (SP-ACE-EC-μPAD) has been developed. The fabrication of these devices involved wax screen-printing, which was simple, low-cost and energy-efficient. The working, counter and reference electrodes were screen-printed using carbon ink on the patterned paper devices. Different wax screen-printing processes were examined and optimized, which led to an improved method with a shorter heating time (~5 s) and a lower heating temperature (75 °C). Different printing screens were examined, with a 300-mesh polyester screen yielding the highest quality wax screen-prints. The carbon electrodes were screen-printed on the μPADs and then examined using cyclic voltammetry. The analytical performance of the SP-ACE-EC-μPADs for the detection of glucose and uric acid in standard solutions was investigated. The results were reproducible, with a linear relationship [R(2) = 0.9987 (glucose) or 0.9997 (uric acid)] within the concentration range of interest, and with detection limits as low as 0.35 mM (glucose) and 0.08 mM (uric acid). To determine the clinical utility of the μPADs, chronoamperometry was used to analyze glucose and uric acid in real urine samples using the standard addition method. Our devices were able to detect the analytes of interest in complex real-world biological samples, and have the potential for use in a wide variety of applications.
Horton, Megan K.; Blount, Benjamin C.; Valentin-Blasini, Liza; Wapner, Ronald; Whyatt, Robin; Gennings, Chris; Factor-Litvak, Pam
2015-01-01
Background Adequate maternal thyroid function during pregnancy is necessary for normal fetal brain development, making pregnancy a critical window of vulnerability to thyroid disrupting insults. Sodium/iodide symporter (NIS) inhibitors, namely perchlorate, nitrate, and thiocyanate, have been shown individually to competitively inhibit uptake of iodine by the thyroid. Several epidemiologic studies examined the association between these individual exposures and thyroid function. Few studies have examined the effect of this chemical mixture on thyroid function during pregnancy. Objectives We examined the cross sectional association between urinary perchlorate, thiocyanate and nitrate concentrations and thyroid function among healthy pregnant women living in New York City using weighted quantile sum (WQS) regression. Methods We measured thyroid stimulating hormone (TSH) and free thyroxine (FreeT4) in blood samples; perchlorate, thiocyanate, nitrate and iodide in urine samples collected from 284 pregnant women at 12 (± 2.8) weeks gestation. We examined associations between urinary analyte concentrations and TSH or FreeT4 using linear regression or WQS adjusting for gestational age, urinary iodide and creatinine. Results Individual analyte concentrations in urine were significantly correlated (Spearman’s r 0.4–0.5, p < 0.001). Linear regression analyses did not suggest associations between individual concentrations and thyroid function. The WQS revealed a significant positive association between the weighted sum of urinary concentrations of the three analytes and increased TSH. Perchlorate had the largest weight in the index, indicating the largest contribution to the WQS. Conclusions Co-exposure to perchlorate, nitrate and thiocyanate may alter maternal thyroid function, specifically TSH, during pregnancy. PMID:26408806
Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D
2013-12-01
Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, < Lower Limit of Quantitation (LLQ); range, < LLQ-43.3 mcg/mL). Significant differences and associations were identified between case status and the following: 1) serum oxalic acid and serum HEAA (both OR = 14.6; 95% C I = 2.8-100.9); 2) serum diglycolic acid and urine diglycolic acid (both OR > 999; exact p < 0.0001); and 3) urinary glycolic acid (OR = 0.057; 95% C I = 0.001-0.55). Two CSF sample results were excluded and two from the same case were averaged, yielding eight samples from eight cases. Diglycolic acid was detected in seven (88%) of case CSF samples (median, 2.03 mcg/mL; range, < LLQ, 7.47). Significantly elevated HEAA (serum) and diglycolic acid (serum and urine) concentrations were identified among cases, which is consistent with animal data. Low urinary glycolic acid concentrations in cases may have been due to concurrent AKI. Although serum glycolic concentrations among cases may have initially increased, further metabolism to oxalic acid may have occurred thereby explaining the similar glycolic acid concentrations in cases and controls. The increased serum oxalic acid concentration results in cases versus controls are consistent with this hypothesis. Diglycolic acid is associated with human DEG poisoning and may be a biomarker for poisoning. These findings add to animal data suggesting a possible role for traditional antidotal therapies. The detection of HEAA and diglycolic acid in the CSF of cases suggests a possible association with signs and symptoms of DEG-associated neurotoxicity. Further work characterizing the pathophysiology of DEG-associated neurotoxicity and the role of traditional toxic alcohol therapies such as fomepizole and hemodialysis is needed.
Kim, Eun-mi; Lee, Ju-seon; Choi, Sang-kil; Lim, Mi-ae; Chung, Hee-sun
2008-01-30
Ketamine (KT) is widely abused for hallucination and also misused as a "date-rape" drug in recent years. An analytical method using positive ion chemical ionization-gas chromatography-mass spectrometry (PCI-GC-MS) with an automatic solid-phase extraction (SPE) apparatus was studied for the determination of KT and its major metabolite, norketamine (NK), in urine. Six ketamine suspected urine samples were provided by the police. For the research of KT metabolism, KT was administered to SD rats by i.p. at a single dose of 5, 10 and 20mg/kg, respectively, and urine samples were collected 24, 48 and 72 h after administration. For the detection of KT and NK, urine samples were extracted on an automatic SPE apparatus (RapidTrace, Zymark) with mixed mode type cartridge, Drug-Clean (200 mg, Alltech). The identification of KT and NK was by PCI-GC-MS. m/z238 (M+1), 220 for KT, m/z 224 (M+1), 207 for NK and m/z307 (M+1) for Cocaine-D(3) as internal standard were extracted from the full-scan mass spectrum and the underlined ions were used for quantitation. Extracted calibration curves were linear from 50 to 1000 ng/mL for KT and NK with correlation coefficients exceeding 0.99. The limit of detection (LOD) was 25 ng/mL for KT and NK. The limit of quantitation (LOQ) was 50 ng/mL for KT and NK. The recoveries of KT and NK at three different concentrations (86, 430 and 860 ng/mL) were 53.1 to 79.7% and 45.7 to 83.0%, respectively. The intra- and inter-day run precisions (CV) for KT and NK were less than 15.0%, and the accuracies (bias) for KT and NK were also less than 15% at the three different concentration levels (86, 430 and 860 ng/mL). The analytical method was also applied to real six KT suspected urine specimens and KT administered rat urines, and the concentrations of KT and NK were determined. Dehydronorketamine (DHNK) was also confirmed in these urine samples, however the concentration of DHNK was not calculated. SPE is simple, and needs less organic solvent than liquid-liquid extraction (LLE), and PCI-GC-MS can offer both qualitative and quantitative information for urinalysis of KT in forensic analysis.
Główka, Franciszek; Karaźniewicz, Marta
2007-08-01
A stereospecific CE method was elaborated for the quantification of ibuprofen enantiomers and their major phase I metabolites: 2'-hydroxy-ibuprofen and 2'-carboxy-ibuprofen in plasma and urine. Optimal temperature and pH of BGE were established to obtain complete separation of eight ibuprofen chiral compounds and (+)-S indobufen, applied as an internal standard, during one analytical run. After isolation from biological matrices using SPE on an octadecyl stationary phase, the analytes were separated and resolved up to 10 min in a silica capillary filled with BGE, consisting of heptakis 2,3,6-tri-O-methyl-beta-CD in triethanolamine-phosphate buffer, pH 5.0. Complete enantioseparation of the all analytes confirmed specificity of the method. The calibration curves were linear in the range of 0.1-25.0 mg/L for IBP enantiomers and their chiral metabolites in 0.5 mL of plasma and 1.0-200.0 mg/L in 0.05 mL of urine. Following SPE procedure, recovery of the chiral analytes from the two media was in the ranges of 82-87%, 90-95% and 70-76% for ibuprofen, 2'-hydroxy-ibuprofen and 2'-carboxy-ibuprofen enantiomers, respectively. The validated method was successfully applied in pharmacokinetic investigations of IBP enantiomers as well as free chiral metabolites in reference to the genetic polymorphism of CYP450 2C isoenzymes.
Shephard, Mark DS; Gill, Janice P
2006-01-01
Type 2 diabetes mellitus and its major complication, renal disease, represent one of the most significant contemporary health problems facing Australia’s Indigenous Aboriginal People. The Australian Government-funded Quality Assurance for Aboriginal Medical Services Program (QAAMS) provides a framework by which on-site point-of-care testing (POCT) for haemoglobin A1c (HbA1c) and now urine albumin:creatinine ratio (ACR) can be performed to facilitate better diabetes management in Aboriginal medical services. This paper provides updated evidence for the analytical quality of POCT in the QAAMS Program. The median imprecision for point-of-care (POC) HbA1c and urine ACR quality assurance (QA) testing has continually improved over the past six and half years, stabilising at approximately 3% for both analytes and proving analytically sound in Aboriginal hands. For HbA1c, there was no statistical difference between the imprecision achieved by QAAMS and laboratory users of the Bayer DCA 2000 since the QAAMS program commenced (QAAMS CV 3.6% ± 0.52, laboratory CV 3.4% ± 0.42; p = 0.21, paired t-test). The Western Pacific Island of Tonga recently joined the QAAMS HbA1c Program indicating that the QAAMS model can also be applied internationally in other settings where the prevalence of diabetes is high. PMID:17581642
Proteases in doping control analysis.
Thevis, M; Maurer, J; Kohler, M; Geyer, H; Schänzer, W
2007-07-01
Urine manipulation in sports drug testing has become a serious problem for doping control laboratories, and recent scandals in elite endurance sports have revealed the problem of urine manipulation presumably using proteases, which will impede the detection of drugs such as erythropoietin (EPO) or other peptide hormones. Using commonly accepted analytical strategies, a protocol was developed enabling the determination of elevated protease activities in doping control specimens followed by the visualization of protein degradation and identification of proteases such as chymotrypsin, trypsin and papain. Therefore, protease detection kits based on fluorescein isothiocyanate-labeled casein were employed, and protease concentrations greater than 15 microg/mL of urine entailed subsequent 1-dimensional gel electrophoretic visualization of urinary proteins. The presence of 20 microg of proteases per mL of urine caused a complete degradation of proteins usually observed in urinary matrices ("trace of burning"), while respective proteases were still detected in spiked urine samples after 10 days of storage at + 4 and - 20 degrees C. Identification of target proteases at respective molecular weights was accomplished using bottom-up sequencing approaches based on in-gel digestion of separated enzymes followed by capillary liquid chromatography--Orbitrap tandem mass spectrometry.
A study examining the bias of albumin and albumin/creatinine ratio measurements in urine.
Jacobson, Beryl E; Seccombe, David W; Katayev, Alex; Levin, Adeera
2015-10-01
The objective of the study was to examine the bias of albumin and albumin/creatinine (ACR) measurements in urine. Pools of normal human urine were augmented with purified human serum albumin to generate a series of 12 samples covering the clinical range of interest for the measurement of ACR. Albumin and creatinine concentrations in these samples were analyzed three times on each of 3 days by 24 accredited laboratories in Canada and the USA. Reference values (RV) for albumin measurements were assigned by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) comparative method and gravimetrically. Ten random urine samples (check samples) were analyzed as singlets and albumin and ACR values reported according to the routine practices of each laboratory. Augmented urine pools were shown to be commutable. Gravimetrically assigned target values were corrected for the presence of endogenous albumin using the LC-MS/MS comparative method. There was excellent agreement between the RVs as assigned by these two methods. All laboratory medians demonstrated a negative bias for the measurement of albumin in urine over the concentration range examined. The magnitude of this bias tended to decrease with increasing albumin concentrations. At baseline, only 10% of the patient ACR values met a performance limit of RV ± 15%. This increased to 84% and 86% following post-analytical correction for albumin and creatinine calibration bias, respectively. International organizations should take a leading role in the standardization of albumin measurements in urine. In the interim, accuracy based urine quality control samples may be used by clinical laboratories for monitoring the accuracy of their urinary albumin measurements.
Buscher, Brigitte; van de Lagemaat, Dick; Gries, Wolfgang; Beyer, Dieter; Markham, Dan A; Budinsky, Robert A; Dimond, Stephen S; Nath, Rajesh V; Snyder, Stephanie A; Hentges, Steven G
2015-11-15
The aim of the presented investigation was to document challenges encountered during implementation and qualification of a method for bisphenol A (BPA) analysis and to develop and discuss precautions taken to avoid and to monitor contamination with BPA during sample handling and analysis. Previously developed and published HPLC-MS/MS methods for the determination of unconjugated BPA (Markham et al. Journal of Analytical Toxicology, 34 (2010) 293-303) [17] and total BPA (Markham et al. Journal of Analytical Toxicology, 38 (2014) 194-203) [20] in human urine were combined and transferred into another laboratory. The initial method for unconjugated BPA was developed and evaluated in two independent laboratories simultaneously. The second method for total BPA was developed and evaluated in one of these laboratories to conserve resources. Accurate analysis of BPA at sub-ppb levels is a challenging task as BPA is a widely used material and is ubiquitous in the environment at trace concentrations. Propensity for contamination of biological samples with BPA is reported in the literature during sample collection, storage, and/or analysis. Contamination by trace levels of BPA is so pervasive that even with extraordinary care, it is difficult to completely exclude the introduction of BPA into biological samples and, consequently, contamination might have an impact on BPA biomonitoring data. The applied UPLC-MS/MS method was calibrated from 0.05 to 25ng/ml. The limit of quantification was 0.1ng/ml for unconjugated BPA and 0.2ng/ml for total BPA, respectively, in human urine. Finally, the method was applied to urine samples derived from 20 volunteers. Overall, BPA can be analyzed in human urine with acceptable recovery and repeatability if sufficient measures are taken to avoid contamination throughout the procedure from sample collection until UPLC-MS/MS analysis. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Wang, Zuwei; Smith, Scott M.
2016-01-01
Urinary free 8-hydroxy-2'-deoxyguanosine (8OHdG), an oxidized product of DNA, and is frequently chosen as a biomarker of oxidative stress in humans, including studies of oxidative DNA damage during space flight. It is challenging to accurately and efficiently quantify urinary free 8OHdG in large scale human studies. LC-MS/MS is emerging as a preferable analytical technique owing its high sensitivity, selectivity and efficiency, compared to some traditional methods such as ELISA and HPLC. A simple and sensitive LC-MS/MS method has been developed for the determination of free 8OHdG in human urine. Sample preparation was done by solid phase extraction with a Waters Oasis HLB 96 well plate. A Waters Alliance 2795 HT Separation Module combined with a Quattro Micro tandem mass spectrometer was used as the LC-MS/MS system. The runtime of one injection can be less than 5 minutes using a reversed phase C18 column and an isocratic flow of methanol/water. ESI positive ions were quantified in the multiple reaction modes (MRM) using m/z 284 yields 168 for 8OHdG and m/z 289 yields173 for stable isotope labeled internal standard [(15)N5] 8OHdG. With this method for 8OHdG, a lower limit of quantitation of 1.0 nM (0.28 ng/mL) has been achieved using 100 microliter urine sample. The analytical range is between 1.0 and 100 nM with a correlation coefficient greater than or equal to 0.99. Good reproducibility can be obtained with intra-assay and inter-assay CVs less than or equal to 10% for 8OHdG spiked urine QC samples. This method can be used in high-throughput routine analysis of free 8OHdG in human urine.
Kabir, Abuzar; Furton, Kenneth G; Tinari, Nicola; Grossi, Laurino; Innosa, Denise; Macerola, Daniela; Tartaglia, Angela; Di Donato, Valentina; D'Ovidio, Cristian; Locatelli, Marcello
2018-05-01
This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of three drug residues (ciprofloxacin, sulfasalazine, and cortisone) in human whole blood, plasma, and urine samples, generally administered in human patients to treat inflammatory bowel disease (IBD). The drugs of interest were well resolved using a Luna C 18 column (250 mm × 4.6 mm; 5 μm particle size) in gradient elution mode within 20 min. The analytical method was optimized and validated in the range 0.05-10 μg/mL for whole blood, 0.25-10 μg/mL for human plasma, and 0.10-10 μg/mL for human urine. Blank human whole blood, plasma, and urine were used as the sample matrix for the method development and validation; while methyl-p-hydroxybenzoate was used as the internal standard (IS). Weighted-matrix matched standard calibration curves showed a good linearity up to a concentration of 10 μg/mL. The intra- and inter-day accuracy values (precision and trueness) were found in the range from -10.9% to 12.3%, and the performances of the validated FPSE-HPLC-PDA were further tested on real IBD patient samples. This is the first FPSE procedure applied simultaneously to whole blood, plasma, and urine samples for the determination of residual IBD drugs, which possess a wide range of polarity (logP values ranging from 2.30 for Ciprofloxacin, to 1.66 for Cortisone, and 2.92 for Sulfasalazine). The new approach exhibits high potential for immediate adoptation as a rapid, robust and green analytical tool for future clinical and pharmaceutical applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Common decision limits --The need for harmonised immunoassays.
Sturgeon, Catharine M
2014-05-15
The main aim of clinical guidelines is to encourage the best clinical outcome for patients and the best use of resources, no matter where patients are investigated or managed. Where guidelines incorporate decision limits based on levels of analytes in serum, plasma or urine these may determine whether or not to treat or may be used to tailor further treatment. Consideration should be given to the effect of method-related differences in results when implementing common decision limits. Available evidence suggests that for some analytes the implications for the patient may be serious, e.g. in terms of missed biopsies or unnecessary prostatic biopsies when prostate specific antigen is measured. Major causes of between-method differences are reviewed and means of addressing them considered. Copyright © 2013 Elsevier B.V. All rights reserved.
The International Space Station Urine Monitoring System (UMS)
NASA Technical Reports Server (NTRS)
Feeback, Daniel L.; Cibuzar, Branelle R.; Milstead, Jeffery R.; Pietrzyk,, Robert A.; Clark, Mark S.F.
2009-01-01
A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification completed prior to placing the instrument into operation. Samples collected during the verification sequence will be returned for analyses on STS-131 (19A) currently scheduled for launch in March 2010. The presence of a UMS on ISS will provide the capability to conduct additional collaborative human life science investigations among the ISS International Partners.
Brenneisen, Rudolf; Meyer, Pascale; Chtioui, Haithem; Saugy, Martial; Kamber, Matthias
2010-04-01
Since 2004, cannabis has been prohibited by the World Anti-Doping Agency for all sports competitions. In the years since then, about half of all positive doping cases in Switzerland have been related to cannabis consumption. In doping urine analysis, the target analyte is 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH), the cutoff being 15 ng/mL. However, the wide urinary detection window of the long-term metabolite of Delta(9)-tetrahydrocannabinol (THC) does not allow a conclusion to be drawn regarding the time of consumption or the impact on the physical performance. The purpose of the present study on light cannabis smokers was to evaluate target analytes with shorter urinary excretion times. Twelve male volunteers smoked a cannabis cigarette standardized to 70 mg THC per cigarette. Plasma and urine were collected up to 8 h and 11 days, respectively. Total THC, 11-hydroxy-Delta(9)-tetrahydrocannabinol (THC-OH), and THC-COOH were determined after hydrolysis followed by solid-phase extraction and gas chromatography/mass spectrometry. The limits of quantitation were 0.1-1.0 ng/mL. Eight puffs delivered a mean THC dose of 45 mg. Plasma levels of total THC, THC-OH, and THC-COOH were measured in the ranges 0.2-59.1, 0.1-3.9, and 0.4-16.4 ng/mL, respectively. Peak concentrations were observed at 5, 5-20, and 20-180 min. Urine levels were measured in the ranges 0.1-1.3, 0.1-14.4, and 0.5-38.2 ng/mL, peaking at 2, 2, and 6-24 h, respectively. The times of the last detectable levels were 2-8, 6-96, and 48-120 h. Besides high to very high THC-COOH levels (245 +/- 1,111 ng/mL), THC (3 +/- 8 ng/mL) and THC-OH (51 +/- 246 ng/mL) were found in 65 and 98% of cannabis-positive athletes' urine samples, respectively. In conclusion, in addition to THC-COOH, the pharmacologically active THC and THC-OH should be used as target analytes for doping urine analysis. In the case of light cannabis use, this may allow the estimation of more recent consumption, probably influencing performance during competitions. However, it is not possible to discriminate the intention of cannabis use, i.e., for recreational or doping purposes. Additionally, pharmacokinetic data of female volunteers are needed to interpret cannabis-positive doping cases of female athletes.
De Monte, Anne; Cannavo, Isabelle; Caramella, Anne; Ollier, Laurence; Giordanengo, Valérie
2016-01-01
Congenital cytomegalovirus (CMV) infection is the leading cause of sensoneurinal disability due to infectious congenital disease. The diagnosis of congenital CMV infection is based on the search of CMV in the urine within the first two weeks of life. Viral culture of urine is the gold standard. However, the PCR is highly sensitive and faster. It is becoming an alternative choice. The objective of this study is the validation of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine. Repeatability, reproducibility, detection limit and inter-sample contamination were evaluated. Urine samples from patients (n=141) were collected and analyzed simultaneously in culture and PCR in order to assess the correlation of these two methods. The sensitivity and specificity of PCR were also calculated. The Abbott RealTime CMV PCR in urine is an automated and sensitive method (detection limit 200 UI/mL). Fidelity is very good (standard deviation of repeatability: 0.08 to 0.15 LogUI/mL and reproducibility 0.18 LogUI/mL). We can note a good correlation between culture and Abbott RealTime CMV PCR (kappa 96%). When considering rapid culture as reference, real-time PCR was highly sensitive (100%) and specific (98.2%). The real-time PCR by Abbott RealTime CMV with m2000 is optimal for CMV detection in urine.
Giordano, Lucia; Coletta, Walter; Rapisarda, Paolo; Donati, Maria Benedetta; Rotilio, Domenico
2007-12-01
Blood orange juice has a high content in anthocyanins, especially represented by delphinidin-3-glucoside (D3G), cyanidin-3-glucoside (C3G) and cyanidin-3-(6-malonylglucoside) (CMG). An LC-MS/MS method for the simultaneous determination of D3G and C3G in human plasma and urine was developed and validated. After sample preparation by SPE, chromatographic separation was performed with an RP-C(18) column, using a water/methanol linear gradient. The quantitation of target compounds was determined by multiple reaction monitoring (MRM) mode, using ESI. The method showed good selectivity, sensitivity (LOD = 0.05 and 0.10 ng/mL for C3G in plasma and urine, respectively; LOD = 0.10 ng/mL for D3G in plasma and urine), linearity (0.20-200 ng/mL; r >or= 0.998), intra- and interday precision and accuracy (
Struys, E A; Jansen, E E W; Gibson, K M; Jakobs, C
2005-01-01
Succinic semialdehyde (SSA) accumulates in the inborn error of meta- bolism succinic semialdehyde dehydrogenase deficiency owing to impaired enzymatic conversion to succinic acid. We developed a stable-isotope dilution liquid chromato- graphy-tandem mass spectrometry method for the determination of SSA in urine and cerebrospinal fluid samples. Stable-isotope-labelled [13C4]SSA, serving as internal standard, was prepared by reaction of ninhydrin with L-[13C5]glutamic acid. SSA in body fluids was converted to its dinitrophenylhydrazine (DNPH) derivative, without sample purification prior to the derivatization procedure. The DNPH derivative of SSA was injected onto a C18 analytical column and chromatography was performed by isocratic elution. Detection was accomplished by tandem mass spectrometry operating in the negative multiple-reaction monitoring mode. The limit of detection was 10 nmol/L and the calibration curves over the range 0-500 pmol of SSA showed good linearity (r2 > 0.99). The intra-day coefficient of variation (n = 10) for urine was 2.7% and inter-day coefficient of variation (n = 5) for urine was 8.5%. The average recoveries performed on two levels by enriching urine and cerebrospinal fluid samples ranged between 85 and 115%, with coefficients of variation < 8%. The method enabled the first determination of normal values for SSA in urine and pathological values of SSA in urine and cerebrospinal fluid samples derived from patients with succinic semialdehyde dehydrogenase deficiency.
Djozan, Djavanshir; Farajzadeh, Mir Ali; Sorouraddin, Saeed Mohammad; Baheri, Tahmineh
2012-07-27
In this study, a developed technique was reported for extraction and pre-concentration of methamphetamine (MAMP) and 3,4-methylenedioxymethamphetamine (MDMA, ecstasy) from urine samples using molecularly imprinted-solid phase extraction (MISPE) along with simultaneous derivatization and dispersive liquid-liquid microextraction (DLLME). Molecularly imprinted microspheres as sorbent in solid phase extraction (SPE) procedure were synthesized using precipitation polymerization with MAMP as the template. Aqueous solution of the target analytes was passed through MAMP-MIP cartridge and the adsorbed analytes were then eluted with methanol. The collected eluate was mixed with butylchloroformate which served as the derivatization reagent as well as the extraction solvent. The mixture was immediately injected into deionized water. After centrifugation, 1 μL of the settled organic phase was injected into gas chromatography-flame ionization detection (GC-FID) or gas chromatography-mass spectrometry (GC-MS). Various experimental parameters affecting the performance of both of the steps (MISPE and DLLME) were thoroughly investigated. The calibration graphs were linear in the ranges of 10-1500 ng mL(-1) (MAMP) and 50-1500 ng mL(-1) (MDMA), and the detection limits (LODs) were 2 and 18 ng mL(-1), respectively. The relative standard deviations (%RSDs) obtained for six repeated experiments (100 ng mL(-1) of each drug) were 5.1% and 6.8% for MAMP and MDMA, respectively. The relative recoveries obtained for the analytes in human urine samples, spiked with different levels of each drug, were within the range of 80-88%. Copyright © 2012 Elsevier B.V. All rights reserved.
Jang, Moonhee; Kim, Jihyun; Han, Inhoi; Yang, Wonkyung
2015-11-10
Lysergic acid diethylamide (LSD) is administered in low dosages, which makes its detection in biological matrices a major challenge in forensic toxicology. In this study, two sensitive and reliable methods based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) were established and validated for the simultaneous determination of LSD and its metabolite, 2-oxo-3-hydroxy-LSD (O-H-LSD), in hair and urine. Target analytes in hair were extracted using methanol at 38°C for 15h and analyzed by LC-MS/MS. For urine sample preparation, liquid-liquid extraction was performed. Limits of detection (LODs) in hair were 0.25pg/mg for LSD and 0.5pg/mg for O-H-LSD. In urine, LODs were 0.01 and 0.025ng/ml for LSD and O-H-LSD, respectively. Method validation results showed good linearity and acceptable precision and accuracy. The developed methods were applied to authentic specimens from two legal cases of LSD ingestion, and allowed identification and quantification of LSD and O-H-LSD in the specimens. In the two cases, LSD concentrations in hair were 1.27 and 0.95pg/mg; O-H-LSD was detected in one case, but its concentration was below the limit of quantification. In urine samples collected from the two suspects 8 and 3h after ingestion, LSD concentrations were 0.48 and 2.70ng/ml, respectively, while O-H-LSD concentrations were 4.19 and 25.2ng/ml, respectively. These methods can be used for documenting LSD intake in clinical and forensic settings. Copyright © 2015 Elsevier B.V. All rights reserved.
Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan
2013-01-01
Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.
Fiorentin, Taís Regina; D'Avila, Felipe Bianchini; Comiran, Eloisa; Zamboni, Amanda; Scherer, Juliana Nichterwitz; Pechansky, Flavio; Borges, Paulo Eduardo Mayorga; Fröehlich, Pedro Eduardo; Limberger, Renata Pereira
2017-07-01
A single LC-MS equipment was used to validate three methods for simultaneously analyzing cocaine (COC), benzoylecgonine (BZE), cocaethylene (CE), anhydroecgonine methyl ester (AEME) and anhydroecgonine (AEC) in oral fluid (OF), urine and plasma. The methods were carried out using a Kinetex HILIC column for polar compounds at 30°C. Mobile phase with isocratic condition of acetonitrile: 13mM ammonium acetate pH 6.0: methanol (55:35:10 v/v/v) at 0.8mL/min flow rate was used. After buffer dilution (OF) and protein precipitation (urine and plasma), calibration curve ranges were 4.25-544ng/mL for oral fluid and 5-320ng/mL for urine and plasma with correlation coefficients (r) between 0.9947 and 0.9992. The lowest concentration of the calibration curves were the lower limit of quantification. No major matrix effect could be noted, demonstrating the efficiency of the cleaning procedure. The methods were fully validated and proved to be suitable for analysis of 124 cocaine and/or crack cocaine users. Among the subjects, 56.5% reported daily use of cocaine in the previous three months. Results show a high prevalence of the analytes, with BZE as the most prevalent (94 cases), followed by COC (93 cases), AEC (70 cases), CE (33 cases) and AEME (13 cases). In addition, the concentration of BZE in urine was higher compared to OF and plasma found in the real samples, showing the facility of accumulation in chronic users in matrices with a large detection window. Copyright © 2017 Elsevier Inc. All rights reserved.
Desrosiers, Nathalie A.; Lee, Dayong; Scheidweiler, Karl B.; Concheiro-Guisan, Marta; Gorelick, David A.; Huestis, Marilyn A.
2014-01-01
Analyte stability is an important factor in urine test interpretation, yet cannabinoid stability data are limited. A comprehensive study of Δ9-tetrahydrocannabinol (THC), 11-hydroxy-THC (11-OH-THC), 11-nor-9-carboxy-THC (THCCOOH), cannabidiol, cannabinol, THC-glucuronide, and THCCOOH-glucuronide stabilities in authentic urine was completed. Urine samples after ad libitum cannabis smoking were pooled to prepare low and high pools for each study participant; baseline concentrations were measured within 24h at room temperature (RT), 4°C and −20°C. Stability at RT, 4°C and −20°C was evaluated by Friedman tests for up to 1 year. THCCOOH, THC-glucuronide, and THCCOOH-glucuronide were quantified in baseline pools. RT THCCOOH baseline concentrations were significantly higher than −20°C, but not 4°C baseline concentrations. After 1 week at RT, THCCOOH increased, THCCOOH-glucuronide decreased, but THC-glucuronide was unchanged. In RT low pool, total THCCOOH (THCCOOH+THCCOOH-glucuronide) was significantly lower after 1 week. At 4°C, THCCOOH was stable 2 weeks, THCCOOH-glucuronide 1 month and THC-glucuronide for at least 6 months. THCCOOH was stable frozen for 1 year, but 6 months high pool results were significantly higher than baseline; THC-glucuronide and THCCOOH-glucuronide were stable for 6 months. Total THCCOOH was stable 6 months at 4°C, and frozen 6 months (low) and 1 year (high). THC, cannabidiol and cannabinol were never detected in urine; although not detected initially, 11-OH-THC was detected in 2 low and 3 high pools after one week at RT. Substantial THCCOOH-glucuronide deconjugation was observed at RT and 4°C. Analysis should be conducted within 3 months if non-hydrolyzed THCCOOH or THCCOOH-glucuronide quantification is required. PMID:24292435
Rosales-Conrado, N; León-González, M E; Pérez-Arribas, L V; Polo-Díez, L M
2008-01-01
Chlorophenoxy acid herbicides are intensively applied to get rid of unwanted plants because of their low cost and selectivity. Due to their toxicity, which depends on their chemical form, the European Community has established legal directives to restrict their use and to control their maximum residue levels in several matrices. Determination of chlorophenoxy acids-2,4-dichlorophenoxyacetic acid (2,4-D), 4-chloro-2-methylphenoxyacetic acid (MCPA), 2-(2,4-dichlorophenoxy)propanoic acid (2,4-DP), 2-(4-chloro-2-methylphenoxy)propanoic acid (MCPP), 4-(4-chloro-2-methylphenoxy)butanoic acid (MCPB) and 2-(2,4,5-trichlorophenoxy)propanoic acid (2,4,5-TP) in spiked human urine samples has been carried out by capillary LC, after solid-phase extraction on a column packed with silica C18 restricted-access material. Chromatographic analysis was performed in gradient-elution mode at 25 degrees C, with injection of 20 microL low-organic-solvent composition herbicide solutions for focusing purposes on the head of the capillary column, and diode array detection at 232 nm. Urine samples collected during 24 h from healthy and unexposed volunteers were spiked in the concentration range 25-150 microg L(-1); recoveries obtained were between 66 and 100% (n = 6 for each spiked level) and RSDs (relative standard deviations) were between 1 and 5%. Detection limits in the urine samples from volunteers were between 3.5 and 6.0 microg L(-1). The developed methodology has allowed the clean-up and preconcentration of low volumes of untreated human urine without previous treatment, showing the effectiveness of the employed SPE sorbent for extracting the target analytes and ultimately resulting in the reduction of the sample-preparation time.
Preliminary study of urine metabolism in type two diabetic patients based on GC-MS
Zhang, Ning; Geng, Fang; Hu, Zhong-Hua; Liu, Bin; Wang, Ye-Qiu; Liu, Jun-Cen; Qi, Yong-Hua; Li, Li-Jing
2016-01-01
Objective: Comparative study of type 2 diabetes and healthy controls by metabolomics methods to explore the pathogenesis of Type II diabetes. Methods: Gas chromatography - mass spectrometry (GC-MS) with a variety of multivariate statistical analysis methods to the healthy control group 58 cases, 68 cases of Type II diabetes group were analyzed. Chromatographic conditions: DB-5MS column; the carrier gas He; flow rate of 1 mL·min-1, the injection volume 1 uL; split ratio is 100: 1. MS conditions: electron impact (EI) ion source, an auxiliary temperature of 280°C, the ion source 230°C, quadrupole 150°C; mass scan range 30~600 mAu. Results: Established analytical method based on urine metabolomics GC-MS of Type II diabetes, determine the urine succinic acid, L-leucine, L-isoleucine, tyrosine, slanine, acetoace acid, mannose, L-isoleucine, L-threonine, Phenylalanine, fructose, D-glucose, palmi acid, oleic acid and arachidonic acid were significantly were significantly changed. Conclusion: Based on metabolomics of GC-MS detection and analysis metabolites can be found differences between type 2 diabetes and healthy control group, PCA diagram can effectively distinguish Type II diabetes and healthy control group, with load diagrams and PLS-DA VIP value metabolite screening, the resulting differences in metabolic pathways involved metabolites, including amino acid metabolism, lipid metabolism, glucose metabolism and energy metabolism. PMID:27508010
López-García, Marina; Romero-González, Roberto; Lacasaña, Marina; Garrido Frenich, Antonia
2017-11-30
A semiautomated method based on ultra-high performance liquid chromatography (UHPLC) coupled to Orbitrap high resolution mass spectrometry has been developed for the determination of neonicotinoids (imidacloprid, acetamiprid, clothianidin, dinotefuran, nitenpyram, thiacloprid and thiamethoxam) and the metabolite acetamiprid-n-desmethyl in urine samples. Two automated methods were tested (solid-phase extraction "SPE" and turbulent flow chromatography "TurboFlow™"), obtaining the best results when TurboFlow™ was applied. The total analysis time for the developed method was 14min. The optimized method was validated, obtaining suitable results for all validation parameters. Recoveries ranged from 78% to 116% meanwhile repeatability and reproducibility were evaluated obtaining values lower than 10% and 20% respectively (except for dinotefuran and nitenpyram at 0.2μgL -1 ). The limit of quantification (LOQ) for all compounds was established at 0.2μgL -1 . The proposed analytical methodology was applied to analyze the target compounds in thirty six urine samples from pregnant women living in agricultural areas of Almería (Spain). Imidacloprid, acetamiprid and acetamiprid-n-desmethyl were detected in some of the samples at concentrations ranging from 0.23 to 1.57μgL -1 . Furthermore, dinotefuran was identified in two samples at trace levels. Copyright © 2017 Elsevier B.V. All rights reserved.
Locatelli, Marcello; Kabir, Abuzar; Innosa, Denise; Lopatriello, Teresa; Furton, Kenneth G
2017-01-01
This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of twelve azole antimicrobial drug residues that include ketoconazole, terconazole, voriconazole, bifonazole, clotrimazole, tioconazole, econazole, butoconazole, miconazole, posaconazole, ravuconazole, and itraconazole in human plasma and urine samples. The selected azole antimicrobial drugs were well resolved by using a Luna C 18 column (250mm×4.6mm; 5μm particle size) in gradient elution mode within 36min. The analytical method was calibrated and validated in the range from 0.1 to 8μg/mL for all the drug compounds. Blank human plasma and urine were used as the sample matrix for the analysis; while benzyl-4-hydroxybenzoate was used as the internal standard (IS). The limit of quantification of the FPSE-HPLC-PDA method was found as 0.1μg/mL and the weighted-matrix matched standard calibration curves of the drugs showed a good linearity upto a concentration of 8μg/mL. The parallelism tests were also performed to evaluate whether overrange sample can be analyzed after dilution, without compromising the analytical performances of the validated method. The intra- and inter-day precision (RSD%) values were found ≤13.1% and ≤13.9%, respectively. The intra- and inter-day trueness (bias%) values were found in the range from -12.1% to 10.5%. The performances of the validated FPSE-HPLC-PDA were further tested on real samples collected from healthy volunteers after a single dose administration of itraconazole and miconazole. To the best of our knowledge, this is the first FPSE extraction procedure applied on plasma and urine samples for the simultaneous determination of twelve azole drugs possessing a wide range of logK ow values (extending from 0.4 for fluconazole to 6.70 of butoconazole) and could be adopted as a rapid and robust green analytical tool for clinical and pharmaceutical applications. Copyright © 2016 Elsevier B.V. All rights reserved.
Ryakitimbo, Amon; Philemon, Rune; Mazuguni, Festo; Msuya, Levina
2018-01-01
Background Urinary tract infection (UTI) in children with cerebral palsy (CP) is a challenging yet common clinical condition. Children with CP bare the greatest risk of contracting UTI because of their difficulties in neuromotor control which lead to delay of bladder control, causing incomplete bladder emptying and urine retention. Method This was an analytical cross-sectional study that was conducted from September 2016 to March 2017 at Comprehensive Community Based Rehabilitation in Tanzania – Moshi and Kilimanjaro Christian Medical Centre Neurological Pediatrics Outpatient Clinic. All children who met the inclusion criteria were studied. Urine samples were collected at one point by catheterization, and urine dipstick and urine culture were done. Data were analyzed using SPSS version 20. Results A total of 99 children were enrolled in the study. The median age was 4 years (3–8 years); 53.5% were aged between 2 and 4 years. More than half were male. UTI was detected in 13.1% (n=13) of the children. Five causative agents of UTI were isolated, namely Escherichia coli, Proteus mirabilis, Klebsiella pneumonia, Staphylococcus aureus, and Enterococcus faecalis. The two most common organisms, E. coli and P. mirabilis, both had low sensitivity to ampicillin and co-trimoxazole while they were sensitive to ciprofloxacin and ceftriaxone. Conclusion UTI is a common finding among children with CP. E. coli and P. mirabilis are the commonest causative agents and are sensitive to ciprofloxacin and ceftriaxone but have low sensitivity to ampicillin and co-trimoxazole. PMID:29774893
Mokube, Morike Ngoe; Atashili, Julius; Halle-Ekane, Gregory Edie; Ikomey, George M; Ndumbe, Peter M
2013-01-01
Bacteriuria is associated with significant maternal and foetal risks. However, its prevalence is not known in our community. This study was carried out to determine the prevalence and predictors of bacteriuria in pregnant women of the Buea Health District (BHD) as well as the antibiotic sensitivity patterns of bacterial isolates. It also sought to determine the diagnostic performance of the nitrite and leucocyte esterase tests in detecting bacteriuria in these women. An observational analytic cross-sectional study was carried out amongst pregnant women attending selected antenatal care centres in Buea. We recruited 102 consenting pregnant women for the study. Demographic and clinical data were collected using structured questionnaires. Clean catch midstream urine was collected from each participant in sterile leak proof containers. Samples were examined biochemically, microscopically and by culture. Significant bacteriuria was defined as the presence of ≥10⁸ bacteria/L of cultured urine. Identification and susceptibility of isolates was performed using API 20E and ATB UR EU (08) (BioMerieux, Marcy l'Etoile, France). Significant bacteriuria was found in the urine of 24 of the 102 women tested giving a bacteriuria prevalence of 23.5% in pregnant women of the BHD. Asymptomatic bacteriuria was detected in 8(7.8%) of the women. There was no statistically significant predictor of bacteriuria. Escherichia coli were the most isolated (33%) uropathogens and were 100% sensitive to cefixime, cefoxitin and cephalothin. The nitrite and leucocyte esterase tests for determining bacteriuria had sensitivities of 8%, 20.8% and specificities of 98.7% and 80.8% respectively. Bacteriuria is frequent in pregnant women in the BHD suggesting the need for routine screening by urine culture. Empiric treatment with cefixime should be instituted until results of urine culture and sensitivity are available. Nitrite and leucocyte esterase tests were not sensitive enough to replace urine culture as screening tests.
Smartphone-based, sensitive µPAD detection of urinary tract infection and gonorrhea.
Cho, Soohee; Park, Tu San; Nahapetian, Tigran G; Yoon, Jeong-Yeol
2015-12-15
The presence of bacteria in urine can be used to monitor the onset or prognosis of urinary tract infection (UTI) and some sexually-transmitted diseases (STDs), such as gonorrhea. Typically, bacteria's presence in urine is confirmed by culturing samples overnight on agar plates, followed by a microscopic examination. Additionally, the presence of Escherichia coli in a urine sample can be indirectly confirmed through assaying for nitrite (generated by reducing nitrate in urine), however this is not sufficiently specific and sensitive. Species/strains identification of bacteria in a urine sample provides insight to appropriate antibiotic treatment options. In this work, a microfluidic paper analytical device (µPAD) was designed and fabricated for evaluating UTI (E. coli) and STD (Neisseria gonorrhoeae) from human urine samples. Anti-E. coli or anti-N. gonorrhoeae antibodies were conjugated to submicron particles then pre-loaded and dried in the center of each paper microfluidic channel. Human urine samples (undiluted) spiked with E. coli or N. gonorrhoeae were incubated for 5 min with 1% Tween 80. The bacteria-spiked urine samples were then introduced to the inlet of paper microfluidic channel, which flowed through the channel by capillary force. Data confirms that proteins were not filtered by μPAD, which is essential for this assay. Urobilin, the component responsible for the yellow appearance of urine and green fluorescence emission, was filtered by μPAD, resulting in significantly minimized false-positive signals. This filtration was simultaneously made during the μPAD assay and no pretreatment/purification step was necessary. Antibody-conjugated particles were immunoagglutinated at the center of the paper channel. The extent of immunoagglutination was quantified by angle-specific Mie scatter under ambient lighting conditions, utilizing a smartphone camera as a detector. The total μPAD assay time was less than 30s. The detection limit was 10 CFU/mL for both E. coli and N. gonorrhoeae, while commercially available gonorrhea rapid kit showed a detection limit of 10(6) CFU/mL. A commercially available nitrite assay test strip also had a detection limit of 10(6) CFU/mL, but this method is not antibody-based and thus not sufficiently specific. By optimizing the particle concentration, we were also able to extend the linear range of the assay up to 10(7) CFU/mL. The proposed prototype will serve as a low-cost, point-of-care, sensitive urinalysis biosensor to monitor UTI and gonorrhea from human urine. Copyright © 2015 Elsevier B.V. All rights reserved.
Mahallei, Majid; Rezaee, Mohammad Ahangarzadeh; Mehramuz, Bahareh; Beheshtirooy, Shayan; Abdinia, Babak
2018-06-01
Sepsis is the systemic response to infection manifested as hyperthermia or hypothermia, tachycardia, tachypnea, and shock. This condition represents a major life-threatening factor in all age groups, particularly in neonatal period. The present study aimed to examine the results of blood, cerebrospinal fluid (CSF), and urine culture tests in suspected neonatal sepsis cases in northwestern Iran.This descriptive-analytical study was conducted on suspected neonatal sepsis cases hospitalized in Tabriz Children's Hospital. All subjects underwent complete blood count with white blood differential, C-reactive protein, blood culture and, if deemed necessary, CSF and urine culture tests and analyses. Laboratory findings in positive culture cases were scored based on the hematological scoring system (HSS) for the diagnosis of neonatal sepsis. The data were then collected, entered into SPSS v18 and analyzed.Among 838 suspected neonatal sepsis cases, 102 (12.17%) neonates with positive cultures were examined; 59.8% of whom were male with a mean age of 9.9 days, gestational age of 36.91 weeks, and mean weight of 2.966 kg. 76.47% of neonates with positive culture were term, 69.6% had normal birth weights, 68.6% were diagnoses with late-onset sepsis, 65.68% had positive blood culture, 38.23% had positive urine culture with no positive CSF culture case. Poor feeding (39.21%) and lethargy (35.29%) were the most common clinical symptoms and previous history of hospital stay (40.19%) and surgery (21.56%) the most common risk factors for neonatal sepsis development. Results revealed that 50 (49.01%) neonates achieved HSS scores equal or greater than 2 (HSS ≥2), and that the mean HSS score in deceased positive blood culture neonates was significantly higher than that of survived ones (2.21 vs 1.37). In this study, coagulase-negative staphylococcus and Staphylococcus aureus represented the most common bacteria isolated from blood with 37.31% and 12.43%, respectively. Fungi (38.5%) and Klebsiella (28.20%) were the most common microorganic urine isolates.The results suggested that only a small percentage of suspected neonatal sepsis cases had positive blood and/or urine cultures (12.17%) and that coagulase-negative staphylococcus (CoNS) and S aureus were highly prevalent in positive blood cultures, whereas fungi and Klebsiella were the most common microorganisms found in positive urine cultures.
Wang, Chun-Chi; Cheng, Shu-Fang; Cheng, Hui-Ling; Chen, Yen-Ling
2013-02-01
This study describes an on-line stacking CE approach by sweeping with whole capillary sample filling for analyzing five anabolic androgenic steroids in urine samples. The five anabolic steroids for detection were androstenedione, testosterone, epitestosterone, boldenone, and clostebol. Anabolic androgenic steroids are abused in sport doping because they can promote muscle growth. Therefore, a sensitive detection method is imperatively required for monitoring the urine samples of athletes. In this research, an interesting and reliable stacking capillary electrophoresis method was established for analysis of anabolic steroids in urine. After liquid-liquid extraction by n-hexane, the supernatant was dried and reconstituted with 30 mM phosphate buffer (pH 5.00) and loaded into the capillary by hydrodynamic injection (10 psi, 99.9 s). The stacking and separation were simultaneously accomplished at -20 kV in phosphate buffer (30 mM, pH 5.0) containing 100 mM sodium dodecyl sulfate and 40 % methanol. During the method validation, calibration curves were linear (r≥0.990) over a range of 50-1,000 ng/mL for the five analytes. In the evaluation of precision and accuracy for this method, the absolute values of the RSD and the RE in the intra-day (n=3) and inter-day (n=5) analyses were all less than 6.6 %. The limit of detection for the five analytes was 30 ng/mL (S/N=5, sampling 99.9 s at 10 psi). Compared with simple MECK, this stacking method possessed a 108- to 175-fold increase in sensitivity. This simple and sensitive stacking method could be used as a powerful tool for monitoring the illegal use of doping.
Cortéjade, A; Kiss, A; Cren, C; Vulliet, E; Buleté, A
2016-01-01
The aim of this study was to develop an analytical method and contribute to the assessment of the Exposome. Thus, a targeted analysis of a wide range of contaminants in contact with humans on daily routines in urine was developed. The method focused on a list of 38 contaminants, including 12 pesticides, one metabolite of pesticide, seven veterinary drugs, five parabens, one UV filter, one plastic additive, two surfactants and nine substances found in different products present in the everyday human environment. These contaminants were analyzed by high performance liquid chromatography coupled to high resolution mass spectrometry (HPLC-HRMS) with a quadrupole-time-of-flight (QqToF) instrument from a raw urinary matrix. A validation according to the FDA guidelines was employed to evaluate the specificity, linear or quadratic curve fitting, inter- and intra-day precision, accuracy and limits of detection and quantification (LOQ). The developed analysis allows for the quantification of 23 contaminants in the urine samples, with the LOQs ranging between 4.3 ng.mL(-1) and 113.2 ng.mL(-1). This method was applied to 17 urine samples. Among the targeted contaminants, four compounds were detected in samples. One of the contaminants (tributyl phosphate) was detected below the LOQ. The three others (4-hydroxybenzoic acid, sodium dodecylbenzenesulfonate and O,O-diethyl thiophosphate potassium) were detected but did not fulfill the validation criteria for quantification. Among these four compounds, two of them were found in all samples: tributyl phosphate and the surfactant sodium dodecylbenzenesulfonate. Copyright © 2015 Elsevier B.V. All rights reserved.
Analyte variations in consecutive 24-hour urine collections in children.
Ellison, Jonathan S; Hollingsworth, John M; Langman, Craig B; Asplin, John R; Schwaderer, Andrew L; Yan, Phyllis; Bierlein, Maggie; Barraza, Mark A; Defoor, William R; Figueroa, T Ernesto; Jackson, Elizabeth C; Jayanthi, Venkata R; Johnson, Emilie K; Joseph, David B; Shnorhavorian, Margarett
2017-12-01
The metabolic evaluation of children with nephrolithiasis begins with a 24-h urine collection. For adults, the diagnostic yield increases with consecutive collections; however, little is known regarding the variability of multiple 24-h studies in the pediatric population. We sought to evaluate the variability of consecutive 24-h urine collection in children through a multi-institutional study hypothesizing that compared with a single collection, consecutive 24-h urine collections would reveal a greater degree of clinically useful information in the evaluation of children at risk for nephrolithiasis. Including data from six institutions, we identified children less than 18 years of age considered at risk for recurrent nephrolithiasis, undergoing metabolic evaluation. We evaluated a subset of patients performing two collections with urine creatinine varying by 10% or less during a 7-day period. Discordance between repeat collections based on normative urine chemistry values was evaluated. A total of 733 children met inclusion criteria, and in over a third both urine calcium and urine volume differed by 30% or more between samples. Urine oxalate demonstrated greater variation between collections in children <5 years than among older children (p = 0.030) while variation in other parameters did not differ by age. Discordance between repeat samples based on normative values was most common for urine oxalate (22.5%) and the derived relative supersaturation ratios for both calcium phosphate (25.1%) and calcium oxalate (20.5%). The proportion of discordant samples, based on normative thresholds, as well as variability greater ≥30% and 50%, respectively, are shown in the table. Our analysis indicates that stone risk in as many as one in four children may be misclassified if normative values of only a single 24-h urine are used. In light of these findings, repeat 24-h urine collections prior to targeted intervention to modify stone risk are advised to increase diagnostic yield in children at risk for nephrolithiasis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Stark, Peter C [Los Alamos, NM; Zurek, Eduardo [Barranquilla, CO; Wheat, Jeffrey V [Fort Walton Beach, FL; Dunbar, John M [Santa Fe, NM; Olivares, Jose A [Los Alamos, NM; Garcia-Rubio, Luis H [Temple Terrace, FL; Ward, Michael D [Los Alamos, NM
2011-07-26
There is provided a method and device for remote sampling, preparation and optical interrogation of a sample using light scattering and light absorption methods. The portable device is a filtration-based device that removes interfering background particle material from the sample matrix by segregating or filtering the chosen analyte from the sample solution or matrix while allowing the interfering background particles to be pumped out of the device. The segregated analyte is then suspended in a diluent for analysis. The device is capable of calculating an initial concentration of the analyte, as well as diluting the analyte such that reliable optical measurements can be made. Suitable analytes include cells, microorganisms, bioparticles, pathogens and diseases. Sample matrixes include biological fluids such as blood and urine, as well as environmental samples including waste water.
Gu, Dan; Raymundo, Melissa M; Kadlubar, Fred F; Turesky, Robert J
2011-02-01
The cooked meat carcinogens 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx), and their principal metabolites produced by cytochrome P450 and/or uridine diphosphate glucuronosyl transferases were simultaneously measured at the parts per trillion level in urine of omnivores, by ultraperformance liquid chromatography (UPLC) with a Michrom Advance CaptiveSpray source and a triple stage quadrupole mass spectrometer. Quantitation was performed in the selected reaction monitoring mode. The UPLC method is much more rapid and sensitive than our earlier capillary HPLC method: the duty cycle of the UPLC method is 19 min compared to 57 min for capillary HPLC. The performance of the UPLC assay was evaluated with urine samples from three subjects over 4 different days. The intraday and interday precisions of the estimates of PhIP, MeIQx, and their metabolites, reported as the coefficients of variation, were ≤10%. The limit of quantification (LOQ) values for PhIP and MeIQx were about 5 pg/mL, whereas the LOQ values of their metabolites ranged from 10 to 40 pg/mL. Furthermore, the identities of the analytes were corroborated by acquisition of full scan product ion spectra, employing between 0.5 and 5 pg of analyte for assay.
Goto, Yoshiyuki; Takeda, Shiho; Araki, Toshinori; Fuchigami, Takayuki
2011-10-01
Stir bar sorptive extraction is a technique used for extracting target substances from various aqueous matrixes such as environmental water, food, and biological samples. This type of extraction is carried out by rotating a coated stir bar is rotated in the sample solution. In particular, Twister bar is a commercial stir bar that is coated with polydimethylsiloxane (PDMS) and used to perform sorptive extraction. In this study, we developed a method for simultaneous detection of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, and a Δ(9)-tetrahydrocannabiniol (THC) metabolite in human urine. For extracting the target analytes, the Twister bar was simply stirred in the sample in the presence of a derivatizing agent. Using this technique, phenethylamines and the acidic THC metabolite can be simultaneously extracted from human urine. This method also enables the extraction of trace amounts of these substances with good reproducibility and high selectivity. The proposed method offers many advantages over other extraction-based approaches and is therefore well suited for screening psychoactive substances in urine specimens.
Chericoni, Silvio; Stefanelli, Fabio; Da Valle, Ylenia; Giusiani, Mario
2015-09-01
A sensitive and reliable method for extraction and quantification of benzoylecgonine (BZE) and cocaine (COC) in urine is presented. Propyl-chloroformate was used as derivatizing agent, and it was directly added to the urine sample: the propyl derivative and COC were then recovered by liquid-liquid extraction procedure. Gas chromatography-mass spectrometry was used to detect the analytes in selected ion monitoring mode. The method proved to be precise for BZE and COC both in term of intraday and interday analysis, with a coefficient of variation (CV)<6%. Limits of detection (LOD) were 2.7 ng/mL for BZE and 1.4 ng/mL for COC. The calibration curve showed a linear relationship for BZE and COC (r2>0.999 and >0.997, respectively) within the range investigated. The method, applied to thirty authentic samples, showed to be very simple, fast, and reliable, so it can be easily applied in routine analysis for the quantification of BZE and COC in urine samples. © 2015 American Academy of Forensic Sciences.
Naraharisetti, Suresh Babu; Kirby, Brian J.; Hebert, Mary F.; Easterling, Thomas R.; Unadkat, Jashvant D.
2009-01-01
Glyburide (glibenclamide, INN), a second generation sulfonylurea is widely used in the treatment of gestational diabetes mellitus (GDM). None of the previously reported analytical methods provide adequate sensitivity for the expected sub-nanogram/mL maternal and umbilical cord plasma concentrations of glyburide during pregnancy. We developed and validated a sensitive and low sample volume liquid chromatographic-mass spectrometric (LC-MS) method for simultaneous determination of glyburide (GLY) and its metabolite, 4-transhydroxy glyburide (M1) in human plasma (0.5 ml) or urine (0.1 ml). The limits of quantitation (LOQ) for GLY and M1 in plasma were 0.25 and 0.40 ng/mL, respectively whereas it was 1.06 ng/mL for M1 in urine. As measured by quality control samples, precision (% coefficient of variation) of the assay was < 15% whereas the accuracy (% deviation from expected) ranged from −10.1–14.3%. We found that the GLY metabolite, M1 is excreted in the urine as the glucuronide-conjugate. PMID:17980680
Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method.
Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, Mahmoudreza; Karami-Osboo, Rouhollah
2013-01-01
Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 μL of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase containing enriched analyte was dissolved in acetonitrile and an aliquot of this solution injected into the HPLC system for analysis. Development of DLLME procedure includes optimization of some important parameters such as kind and volume of extraction and disperser solvent, pH and salt addition. The proposed method has good linearity in the range of 0.02-4.5 μg mL(-1) and low detection limit (13.1 ng mL(-1)). The repeatability of the method, expressed as relative standard deviation was 4.9% (n = 3). This method has also been applied to the analysis of real urine samples with satisfactory relative recoveries in the range of 91.6-101.0%.
Blood, breath and urine represent the three primary diagnostic fluids for assessing environmental exposures and human health state. Although there is overlap in biological media choice for many applications, each have their individual strategic and analytical advantages: Blood is...
DETERMINATION OF 3,5,6-TRICHLORO-2-PYRIDINOL (TCP) BY ELISA
A sensitive, competitive enzyme-linked immunosorbent assay (ELISA) for 3,5,6-trichloro-2pyridinol (TCP) has been developed to quantitate parts per billion (ppb) amounts of the analyte in urine. TCP is a major metabolite and environmental degradation product of the insecticide c...
Interpretation of Oral Fluid Tests for Drugs of Abuse
CONE, EDWARD J.; HUESTIS, MARILYN A.
2009-01-01
Oral fluid testing for drugs of abuse offers significant advantages over urine as a test matrix. Collection can be performed under direct observation with reduced risk of adulteration and substitution. Drugs generally appear in oral fluid by passive diffusion from blood, but also may be deposited in the oral cavity during oral, smoked, and intranasal administration. Drug metabolites also can be detected in oral fluid. Unlike urine testing, there may be a close correspondence between drug and metabolite concentrations in oral fluid and in blood. Interpretation of oral fluid results for drugs of abuse should be an iterative process whereby one considers the test results in the context of program requirements and a broad scientific knowledge of the many factors involved in determining test outcome. This review delineates many of the chemical and metabolic processes involved in the disposition of drugs and metabolites in oral fluid that are important to the appropriate interpretation of oral fluid tests. Chemical, metabolic, kinetic, and analytic parameters are summarized for selected drugs of abuse, and general guidelines are offered for understanding the significance of oral fluid tests. PMID:17332074
NASA Astrophysics Data System (ADS)
Miyaoka, Teiji; Isono, Yoshimi; Setani, Kaoru; Sakai, Kumiko; Yamada, Ichimaro; Sato, Yoshiaki; Gunji, Shinobu; Matsui, Takao
2007-06-01
Institute of Accelerator Analysis Ltd. (IAA) is the first Contract Research Organization in Japan providing Accelerator Mass Spectrometry (AMS) analysis services for carbon dating and bioanalysis works. The 3 MV AMS machines are maintained by validated analysis methods using multiple control compounds. It is confirmed that these AMS systems have reliabilities and sensitivities enough for each objective. The graphitization of samples for bioanalysis is prepared by our own purification lines including the measurement of total carbon content in the sample automatically. In this paper, we present the use of AMS analysis in human mass balance and metabolism profiling studies with IAA 3 MV AMS, comparing results obtained from the same samples with liquid scintillation counting (LSC). Human samples such as plasma, urine and feces were obtained from four healthy volunteers orally administered a 14C-labeled drug Y-700, a novel xanthine oxidase inhibitor, of which radioactivity was about 3 MBq (85 μCi). For AMS measurement, these samples were diluted 100-10,000-fold with pure-water or blank samples. The results indicated that AMS method had a good correlation with LSC method (e.g. plasma: r = 0.998, urine: r = 0.997, feces: r = 0.997), and that the drug recovery in the excreta exceeded 92%. The metabolite profiles of plasma, urine and feces obtained with HPLC-AMS corresponded to radio-HPLC results measured at much higher radioactivity level. These results revealed that AMS analysis at IAA is useful to measure 14C-concentration in bioanalysis studies at very low radioactivity level.
The Analysis of Riboflavin in Urine Using Fluorescence
NASA Astrophysics Data System (ADS)
Henderleiter, Julie A.; Hyslop, Richard M.
1996-06-01
To become functional as scientists, chemistry students must integrate concepts learned in their classes and apply them to novel, "real life" situations. The laboratory provides an important place for the students to practice integrating concepts. This laboratory experiment, designed for undergraduate biochemistry students, requires each student to determine the amount of riboflavin excreted by his/her body following oral administration of riboflavin contained in a multi-vitamin tablet. The experimental procedure describes a protocol for the analysis of riboflavin concentration in urine using a fluorometric assay. The students must draw upon their knowledge of solution preparation, construction of a standard curve, and back-calculation procedures to determine the concentration of riboflavin in their urine. Students need to combine knowledge from general and analytical chemistry with that learned in biochemistry to complete this analysis, thus providing an opportunity to integrate knowledge while answering a novel question.
Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan
2016-06-05
In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Urinary MicroRNA as Biomarker in Renal Transplantation.
van de Vrie, M; Deegens, J K; Eikmans, M; van der Vlag, J; Hilbrands, L B
2017-05-01
Urine represents a noninvasive source in which proteins and nucleic acids can be assessed. Such analytes may function as biomarkers to monitor kidney graft pathology at every desired frequency, thereby providing a time window to prevent graft damage by therapeutic intervention. Recently, several proteins have been measured in urine as markers of graft injury. However, the specificity is limited, and measuring urinary proteins generally lacks the potential to predict early kidney graft damage. Currently, urinary mRNA and microRNA are being investigated to evaluate the prognostic value of changes in gene expression during the initial stages of graft damage. At such time point, a change in treatment regimen and dosage is expected to have maximum potency to minimize future decline in graft function. Both mRNA and microRNAs have shown promising results in both detection and prediction of graft injury. An advantage of microRNAs compared to mRNA molecules is their stability, a characteristic that is beneficial when working with urine samples. In this review, we provide the current state of urinary biomarkers in renal transplantation, with a focus on urinary microRNA. In addition, we discuss the methods used to study urinary microRNA expression. © 2016 The Authors. American Journal of Transplantation published by Wiley Periodicals, Inc. on behalf of American Society of Transplant Surgeons.
NASA Astrophysics Data System (ADS)
Pasaribu, H. P.; Hanifa, A.; Tala, R. Z.; Ardiansyah, E.; Simanjuntak, R. Y.; Effendy, I. H.
2018-03-01
UTI is an infection that occurs in the urinary tract due to the proliferation of a microorganism. Female is fourteen times more vulnerable to UTI than male, because their urethra is shorter. Bladder epithelium is coated with a thin layer of glycosaminoglycans which act as a non-specific anti-adherence factor and nonspecific defense mechanisms against infection and can be found in the urine. An analytic study with cross sectional approach was conducted in 46 patients (23 with UTI and 23 non UTI) from June 2016 to determine differences in levels of urinary glycosaminoglycans between two groups. Urine samples were taken and tested for UTI and non UTI strips test. Laboratory examination of urine GAGs levels using ELISA kit for Human Glycosaminoglycans, then tabulated and analyzed using SPSS. The result showed no significant differences in the characteristics of women between two groups. There are significant differences in the mean levels of urinary GAGs in women with UTI compared with Non-UTI (69.74 ± 21.34; 21.39 ± 2.61 mg/l; p <0.001). There was no significant relationship between the sexual status and UTI incidence, with low odds ratio values and no significant difference in the mean of urinary glicosaminoglycans level based on sexual status.
Goettel, Michael; Niessner, Reinhard; Mueller, Daniel; Scherer, Max; Scherer, Gerhard; Pluym, Nikola
2017-10-06
Untargeted GC-TOF-MS analysis proved to be a suitable analytical platform to determine alterations in the metabolic profile. Several metabolic pathways were found to be altered in a first clinical study comparing smokers against nonsmokers. Subsequently, we conducted a clinical diet-controlled study to investigate alterations in the metabolic profile during the course of 3 months of smoking cessation. Sixty male subjects were included in the study, and plasma, saliva, and urine samples were collected during four 24 h stationary visits: at baseline, while still smoking, after 1 week, after 1 month, and after 3 months of cessation. Additionally, subjects were monitored for their compliance by measurements of CO in exhaled breath and salivary cotinine throughout the study. GC-TOF-MS fingerprinting was applied to plasma, saliva, and urine samples derived from 39 compliant subjects. In total, 52 metabolites were found to be significantly altered including 26 in plasma, 20 in saliva, and 12 in urine, respectively. In agreement with a previous study comparing smokers and nonsmokers, the fatty acid and amino acid metabolism showed significant alterations upon 3 months of smoking cessation. Thus these results may indicate a partial recovery of metabolic pathway perturbations, even after a relatively short period of smoking cessation.
Stout, Peter R; Horn, Carl K; Klette, Kevin L
2002-01-01
To facilitate analysis of high sample volumes, an extraction, derivatization and gas chromatographic-mass spectrometric analysis method was developed to simultaneously determine amphetamine (AMP), methamphetamine (MAMP), 3,4-methylenedioxyamphetamine (MDA) 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyethylamphetamine (MDEA) in urine. This method utilized a positive-pressure manifold cation-exchange polymer-based solid-phase extraction followed by elution directly into automated liquid sampler (ALS) vials. Rapid derivatization was accomplished using heptafluorobutyric anhydride (HFBA). Recoveries averaged 90% or greater for each of the compounds. Limits of detection were 62.5 ng/mL (AMP and MDEA), 15.6 ng/mL (MAMP), and 31.3 ng/mL (MDA and MDMA) using a 2-mL sample volume. The method was linear to 5000 ng/mL for all compounds using MDMA-d5 and MAMP-d14 as internal standards. Over 200 human urine samples previously determined to contain the target analytes were analyzed using the method. Excellent agreement was seen with previous quantitations. The method was challenged with 75 potentially interfering compounds and no interferences were seen. These interfering compounds included ephedrine, pseudoephedrine, phenylpropanolamine, and phenethylamine. The method resulted in dramatic reductions in processing time and waste production.
Ma, Junlong; Wang, Chengbin; Yue, Jiaxin; Li, Mianyang; Zhang, Hongrui; Ma, Xiaojing; Li, Xincui; Xue, Dandan; Qing, Xiaoyan; Wang, Shengjiang; Xiang, Daijun; Cong, Yulong
2013-01-01
Several automated urine sediment analyzers have been introduced to clinical laboratories. Automated microscopic pattern recognition is a new technique for urine particle analysis. We evaluated the analytical and diagnostic performance of the UriSed automated microscopic analyzer and compared with manual microscopy for urine sediment analysis. Precision, linearity, carry-over, and method comparison were carried out. A total of 600 urine samples sent for urinalysis were assessed using the UriSed automated microscopic analyzer and manual microscopy. Within-run and between-run precision of the UriSed for red blood cells (RBC) and white blood cells (WBC) were acceptable at all levels (CV < 20%). Within-run and between-run imprecision of the UriSed testing for cast, squamous epithelial cells (EPI), and bacteria (BAC) were good at middle level and high level (CV < 20%). The linearity analysis revealed substantial agreement between the measured value and the theoretical value of the UriSed for RBC, WBC, cast, EPI, and BAC (r > 0.95). There was no carry-over. RBC, WBC, and squamous epithelial cells with sensitivities and specificities were more than 80% in this study. There is substantial agreement between the UriSed automated microscopic analyzer and the manual microscopy methods. The UriSed provides for a rapid turnaround time.
da Costa, José Luiz; da Matta Chasin, Alice Aparecida
2004-11-05
This paper describes the development and validation of analytical methodology for the determination of the use of MDMA, MDEA and MDA in urine. After a simple liquid extraction, the analyses were carried out on a high performance liquid chromatography (HPLC) in an octadecyl column, with fluorescence detection. The mobile phase using a sodium dodecyl sulfate ion-pairing reagent allows good separation and efficiency. The method showed good linearity and precision. Recovery was between 85 and 102% and detection limits were 10, 15 and 20 ng/ml for MDA, MDMA and MDEA, respectively. No interfering substances were detected with fluorescence detection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-05-01
This technical bulletin provides analytical techniques to identify toxic chemical agents in urine or blood samples. It is intended to provide the clinician with laboratory tests to detect exposure to sulfur mustard, cholinesterase inhibitors, sarin, soman, GF, and cyanide.
Determination of zilpaterol in sheep urine and tissues using immunochromatographic assay
USDA-ARS?s Scientific Manuscript database
Introduction: Zilpaterol is a feed additive used to increase weight gain, improve feed efficiency, and increase carcass leanness in cattle. An on-site analytical method is needed to determine zilpaterol exposure in animals to assist producer and trade groups in avoiding un-necessary animal or carca...
Karasakal, A; Ulu, S T
2014-05-01
A novel, sensitive and selective spectrofluorimetric method was developed for the determination of tamsulosin in spiked human urine and pharmaceutical preparations. The proposed method is based on the reaction of tamsulosin with 1-dimethylaminonaphthalene-5-sulfonyl chloride in carbonate buffer pH 10.5 to yield a highly fluorescent derivative. The described method was validated and the analytical parameters of linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, recovery and robustness were evaluated. The proposed method showed a linear dependence of the fluorescence intensity on drug concentration over the range 1.22 × 10(-7) to 7.35 × 10(-6) M. LOD and LOQ were calculated as 1.07 × 10(-7) and 3.23 × 10(-7) M, respectively. The proposed method was successfully applied for the determination of tamsulosin in pharmaceutical preparations and the obtained results were in good agreement with those obtained using the reference method. Copyright © 2013 John Wiley & Sons, Ltd.
Barricklow, Jason; Ryder, Tim F; Furlong, Michael T
2009-08-01
During LC-MS/MS quantification of a small molecule in human urine samples from a clinical study, an unexpected peak was observed to nearly co-elute with the analyte of interest in many study samples. Improved chromatographic resolution revealed the presence of at least 3 non-analyte peaks, which were identified as cysteine metabolites and N-acetyl (mercapturic acid) derivatives thereof. These metabolites produced artifact responses in the parent compound MRM channel due to decomposition in the ionization source of the mass spectrometer. Quantitative comparison of the analyte concentrations in study samples using the original chromatographic method and the improved chromatographic separation method demonstrated that the original method substantially over-estimated the analyte concentration in many cases. The substitution of electrospray ionization (ESI) for atmospheric pressure chemical ionization (APCI) nearly eliminated the source instability of these metabolites, which would have mitigated their interference in the quantification of the analyte, even without chromatographic separation. These results 1) demonstrate the potential for thiol metabolite interferences during the quantification of small molecules in pharmacokinetic samples, and 2) underscore the need to carefully evaluate LC-MS/MS methods for molecules that can undergo metabolism to thiol adducts to ensure that they are not susceptible to such interferences during quantification.
The Statistical Value of Raw Fluorescence Signal in Luminex xMAP Based Multiplex Immunoassays
Breen, Edmond J.; Tan, Woei; Khan, Alamgir
2016-01-01
Tissue samples (plasma, saliva, serum or urine) from 169 patients classified as either normal or having one of seven possible diseases are analysed across three 96-well plates for the presences of 37 analytes using cytokine inflammation multiplexed immunoassay panels. Censoring for concentration data caused problems for analysis of the low abundant analytes. Using fluorescence analysis over concentration based analysis allowed analysis of these low abundant analytes. Mixed-effects analysis on the resulting fluorescence and concentration responses reveals a combination of censoring and mapping the fluorescence responses to concentration values, through a 5PL curve, changed observed analyte concentrations. Simulation verifies this, by showing a dependence on the mean florescence response and its distribution on the observed analyte concentration levels. Differences from normality, in the fluorescence responses, can lead to differences in concentration estimates and unreliable probabilities for treatment effects. It is seen that when fluorescence responses are normally distributed, probabilities of treatment effects for fluorescence based t-tests has greater statistical power than the same probabilities from concentration based t-tests. We add evidence that the fluorescence response, unlike concentration values, doesn’t require censoring and we show with respect to differential analysis on the fluorescence responses that background correction is not required. PMID:27243383
Performance evaluation of three on-site adulterant detection devices for urine specimens.
Peace, Michelle R; Tarnai, Lisa D
2002-10-01
The performance of three on-site adulterant detection devices that assess the integrity of urine specimens collected for drug-of-abuse testing was evaluated: the Intect 7, MASK Ultra Screen, and Adultacheck 4. Intect 7 simultaneously tests creatinine, nitrite, glutaraldehyde, pH, specific gravity, and the presence of bleach and pyridinium chlorochromate (PCC). Mask Ultra Screen tests creatinine, nitrite, pH, specific gravity, and oxidants, and Adultacheck 4 tests creatinine, nitrite, glutaraldehyde, and pH. Urine specimens were prepared with the Substance Abuse and Mental Health Administration regulated analytes at 50% above the cut-off concentrations. Stealth, Urine Luck, Instant Clean ADD-IT-ive, and KLEAR were added individually to the drug-added urine specimens so that their concentrations reflected the "optimum" usage reported in their package inserts and 25% above and below that optimum. Stealth is reported to be peroxidase; Urine Luck is believed to be PCC; Instant Clean ADD-it-ive reportedly contains glutaraldehyde, and Klear is a nitrite. The following diluents/adulterants were added at 25%, 33%, and 50% of the volume of drug-added urine: distilled water, bleach, ammonia, and vinegar. Of the devices tested, Intect 7 proved to be the most sensitive, and it correctly indicated the presence of adulterant or diluent in all samples tested. In order to do so, all indication pads had to be assessed in concert. Adultacheck 4 specifically assesses four characteristics of urine integrity and is therefore very limited in detecting the use of several popular adulterants that are commercially available. Although it correctly assessed the four characteristics, it did not detect the use of Stealth, Urine Luck, or Instant Clean ADD-it-ive. Mask Ultra Screen can potentially detect a broader range of adulterants than Adultacheck 4. However, in practice, it only detected them at levels well above their optimum usage, making it less efficacious than Intect 7. Clearly, the specific identification of an adulterant is a trade-off for sensitive detection of several adulterants.
Bouatra, Souhaila; Aziat, Farid; Mandal, Rupasri; Guo, An Chi; Wilson, Michael R.; Knox, Craig; Bjorndahl, Trent C.; Krishnamurthy, Ramanarayan; Saleem, Fozia; Liu, Philip; Dame, Zerihun T.; Poelzer, Jenna; Huynh, Jessica; Yallou, Faizath S.; Psychogios, Nick; Dong, Edison; Bogumil, Ralf; Roehring, Cornelia; Wishart, David S.
2013-01-01
Urine has long been a “favored” biofluid among metabolomics researchers. It is sterile, easy-to-obtain in large volumes, largely free from interfering proteins or lipids and chemically complex. However, this chemical complexity has also made urine a particularly difficult substrate to fully understand. As a biological waste material, urine typically contains metabolic breakdown products from a wide range of foods, drinks, drugs, environmental contaminants, endogenous waste metabolites and bacterial by-products. Many of these compounds are poorly characterized and poorly understood. In an effort to improve our understanding of this biofluid we have undertaken a comprehensive, quantitative, metabolome-wide characterization of human urine. This involved both computer-aided literature mining and comprehensive, quantitative experimental assessment/validation. The experimental portion employed NMR spectroscopy, gas chromatography mass spectrometry (GC-MS), direct flow injection mass spectrometry (DFI/LC-MS/MS), inductively coupled plasma mass spectrometry (ICP-MS) and high performance liquid chromatography (HPLC) experiments performed on multiple human urine samples. This multi-platform metabolomic analysis allowed us to identify 445 and quantify 378 unique urine metabolites or metabolite species. The different analytical platforms were able to identify (quantify) a total of: 209 (209) by NMR, 179 (85) by GC-MS, 127 (127) by DFI/LC-MS/MS, 40 (40) by ICP-MS and 10 (10) by HPLC. Our use of multiple metabolomics platforms and technologies allowed us to identify several previously unknown urine metabolites and to substantially enhance the level of metabolome coverage. It also allowed us to critically assess the relative strengths and weaknesses of different platforms or technologies. The literature review led to the identification and annotation of another 2206 urinary compounds and was used to help guide the subsequent experimental studies. An online database containing the complete set of 2651 confirmed human urine metabolite species, their structures (3079 in total), concentrations, related literature references and links to their known disease associations are freely available at http://www.urinemetabolome.ca. PMID:24023812
Sobus, Jon R.; McClean, Michael D.; Herrick, Robert F.; Waidyanatha, Suramya; Nylander-French, Leena A.; Kupper, Lawrence L.; Rappaport, Stephen M.
2009-01-01
When working with hot mix asphalt, road pavers are exposed to polycyclic aromatic hydrocarbons (PAHs) through the inhalation of vapors and particulate matter (PM) and through dermal contact with PM and contaminated surfaces. Several PAHs with four to six rings are potent carcinogens which reside in these particulate emissions. Since urinary biomarkers of large PAHs are rarely detectable in asphalt workers, attention has focused upon urinary levels of the more volatile and abundant two-ring and three-ring PAHs as potential biomarkers of PAH exposure. Here, we compare levels of particulate polycyclic aromatic compounds (P-PACs, a group of aromatic hydrocarbons containing PAHs and heterocyclic compounds with four or more rings) in air and dermal patch samples from 20 road pavers to the corresponding urinary levels of naphthalene (U-Nap) (two rings), phenanthrene (U-Phe) (three rings), monohydroxylated metabolites of naphthalene (OH-Nap) and phenanthrene (OH-Phe), and 1-hydroxypyrene (OH-Pyr) (four rings), the most widely used biomarker of PAH exposure. For each worker, daily breathing-zone air (n = 55) and dermal patch samples (n = 56) were collected on three consecutive workdays along with postshift, bedtime, and morning urine samples (n = 149). Measured levels of P-PACs and the urinary analytes were used to statistically model exposure–biomarker relationships while controlling for urinary creatinine, smoking status, age, body mass index, and the timing of urine sampling. Levels of OH-Phe in urine collected postshift, at bedtime, and the following morning were all significantly associated with levels of P-PACs in air and dermal patch samples. For U-Nap, U-Phe, and OH-Pyr, both air and dermal patch measurements of P-PACs were significant predictors of postshift urine levels, and dermal patch measurements were significant predictors of bedtime urine levels (all three analytes) and morning urine levels (U-Nap and OH-Pyr only). Significant effects of creatinine concentration were observed for all analytes, and modest effects of smoking status and body mass index were observed for U-Phe and OH-Pyr, respectively. Levels of OH-Nap were not associated with P-PAC measurements in air or dermal patch samples but were significantly affected by smoking status, age, day of sample collection, and urinary creatinine. We conclude that U-Nap, U-Phe, OH-Phe, and OH-Pyr can be used as biomarkers of exposure to particulate asphalt emissions, with OH-Phe being the most promising candidate. Indications that levels of U-Nap, U-Phe, and OH-Pyr were significantly associated with dermal patch measurements well into the evening after a given work shift, combined with the small ratios of within-person variance components to between-person variance components at bedtime, suggest that bedtime measurements may be useful for investigating dermal PAH exposures. PMID:19602502
Tao, Lin; Chen, Mei; Collins, Erin; Lu, Chensheng
2013-02-01
Pyrethroid insecticides are applied in the residential environment, as well as in agricultural crops, for insect control purpose. We developed and validated an accurate, sensitive, and reproducible analytical method to simultaneously detect seven pyrethroid metabolites, namely, 3-(2,2-dichlorovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid, 3-(2,2-dibromovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid, 3-phenoxybenzoic acid, 4-fluoro-3-phenoxybenzoic acid, 2-methyl-3-phenylbenzoic acid, 4-chloro-α-isoproply benzeneacetic acid, and 3-(2-chloro-3,3,3-trifluoroprop-1-enyl)-2,2-dimethylcyclopropanecarboxylic acid, in human urine. This method employs deconjugation with enzyme, SPE using Agilent C18 cartridges on a RapidTrace SPE workstation, derivatization using hexafluoro isopropanol and N,N'-diisopropylcarbodiimide, and compounds separation and identification on GC-MS. The detection limits of seven metabolites were 0.02-0.08 ng/mL in urine. The recoveries of seven metabolites were 81-104%, 85-99%, and 83-99% in urine specimens fortified at 0.1, 0.4, and 3.2 ng/mL concentrations, respectively. The overall coefficient of variation was 4.3-10.8% in two quality control specimens which were repeatedly measured during a period of 2 months. This method was applied to urine samples collected from children living in Boston, MA. The median concentrations of six detected pyrethroid metabolites ranged from 0.06 to 0.86 ng/mL in urine. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yamamuro, Tadashi; Ohta, Hikoto; Aoyama, Mika; Watanabe, Daisuke
2014-10-15
A rapid and sensitive analytical method was developed for simultaneous determination of eight neonicotinoid insecticides (acetamiprid, clothianidin, dinotefuran, flonicamid, imidacloprid, nitenpyram, thiacloprid and thiamethoxam) and three specific metabolites of acetamiprid (N-desmethylacetamiprid, 5-(N-acetyl-N-methylaminomethyl)-2-chloropyridine and 5-(N-acetylaminomethyl)-2-chloropyridine) in human serum and urine. A diatomaceous earth-assisted extraction using Extrelut NT3 column with chloroform/2-propanol (3:1, v/v) as eluent was selected for the single step cleanup procedure for all the target compounds. Qualitative and quantitative analyses were conducted by liquid chromatography-tandem mass spectrometry with multiple reaction monitoring mode. The limits of detection and the limits of quantification of eleven compounds were in the ranges of 0.1-0.2ng/mL and 0.5-10ng/mL for serum, 0.1-1ng/mL and 1-10ng/mL for urine, respectively. The extraction recoveries were between 80.9% and 101.8% for serum samples, 91.9% and 106% for urine samples. The intra-day RSDs and the inter-day RSDs were less than 11.5% and 13.2% for serum, less than 8.3% and 8.8% for urine. The proposed procedure will be suitable for forensic investigations of human poisoning cases with neonicotinoid insecticides. This is the first report of simultaneous determination of eight neonicotinoids in serum and urine samples. Copyright © 2014. Published by Elsevier B.V.
Zhang, Shuo; Zhao, Yunfeng; Li, Haijiao; Zhou, Shuang; Chen, Dawei; Zhang, Yizhe; Yao, Qunmei; Sun, Chengye
2016-01-01
Amatoxins and phallotoxins are toxic cyclopeptides found in the genus Amanita and are among the predominant causes of fatal food poisoning in China. In the treatment of Amanita mushroom poisoning, an early and definite diagnosis is necessary for a successful outcome, which has prompted the development of protocols for the fast and confirmatory determination of amatoxins and phallotoxins in human biological fluids. For this purpose, a simple, rapid and sensitive multiresidue UPLC-MS/MS method for the simultaneous determination of α-amanitin, β-amanitin, γ-amanitin, phalloidin (PHD) and phallacidin (PCD) in human plasma, serum and urine was developed and validated. The diluted plasma, serum and urine samples were directly purified with a novel PRiME technique on a 96-well μElution plate platform, which allowed high-throughput sample processing and low reagent consumption. After purification, a UPLC-MS/MS analysis was performed using positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode. This method fulfilled the requirements of a validation test, with good results for the limit of detection (LOD), lower limit of quantification (LLOQ), accuracy, intra- and inter-assay precision, recovery and matrix effects. All of the analytes were confirmed and quantified in authentic plasma, serum and urine samples obtained from cases of poisoning using this method. Using the PRiME μElution technique for quantification reduces labor and time costs and represents a suitable method for routine toxicological and clinical emergency analysis. PMID:27153089
Yang, Jiajia; Li, Yun; Wang, Jincheng; Sun, Xiaoli; Cao, Rong; Sun, Hao; Huang, Chaonan; Chen, Jiping
2015-05-04
The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption-desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30-60 μm), a specific surface area (S(BET)) of 281.26 m(2) g(-1) and a total pore volume (V(t)) of 0.459 cm(3) g(-1). Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2-2.2 ng mL(-1). The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL(-1) for each BP) were in the range of 81.3-106.7% with RSD values below 8.3%. Copyright © 2015 Elsevier B.V. All rights reserved.
Alimemazine poisoning as evidence of Munchausen syndrome by proxy: A pediatric case report.
Gomila, Isabel; López-Corominas, Victoria; Pellegrini, Manuela; Quesada, Loreto; Miravet, Elena; Pichini, Simona; Barceló, Bernardino
2016-09-01
Munchausen syndrome by proxy (MSBP), also known as fabricated or induced illness in a child by a caretaker, is a form of abuse where a caregiver deliberately produces or feigns illness in a person under his or her care, so that the proxy will receive medical care that gratifies the caregiver. The affected children are often hospitalized for long periods and endure repetitive, painful and expensive diagnostic attempts. We present an analytically confirmed case of MSBP by alimemazine. A 3-year-old boy was brought repetitively to a Pediatric Emergency Department by his mother because he presented limb tremors, dysarthria, obnubilation, and ataxia and generalized tonic-clonic seizures coinciding with intermittent fever. Neither the rest of the physical examination nor the complementary tests showed any significant alterations. MSBP was suspected and a routine systematic toxicological analysis in urine and blood was requested. Alimemazine was detected in all biological samples. The administration of this drug was never mentioned by the mother and the subsequent interview with her corroborated the suspicion of MSBP. Clinically, after separation from the mother, the child's neurological symptoms gradually improved until the complete disappearance of the cerebellar symptoms. Alimemazine was quantified in serum, urine, gastric content and cerebrospinal fluid samples by gas chromatography-mass spectrometry (maximum serum level was 0.42μg/ml). Hair quantification of alimemazine was performed by ultra-performance liquid chromatography-tandem mass spectrometry in different segments of hair. The results confirmed regular substance use during the at least eight last months (8.8, 14.7, 19.7 and 4.6ng/mg hair starting from most proximal segment). This patient represents the first case published with analytical data of alimemazine in blood, urine, gastric content, cerebrospinal fluid and hair, which allowed us to prove an acute and repetitive poisoning with alimemazine as evidence of MSBP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Naccarato, Attilio; Elliani, Rosangela; Cavaliere, Brunella; Sindona, Giovanni; Tagarelli, Antonio
2018-05-11
Polyamines are aliphatic amines with low molecular weight that are widely recognized as one of the most important cancer biomarkers for early diagnosis and treatment. The goal of the work herein presented is the development of a rapid and simple method for the quantification of free polyamines (i.e., putrescine, cadaverine, spermidine, spermine) and N-monoacetylated polyamines (i.e., N 1 -Acetylspermidine, N 8 -Acetylspermidine, and N 1 -Acetylspermine) in human urine. A preliminary derivatization with propyl chloroformate combined with the use of solid phase microextraction (SPME) allowed for an easy and automatable protocol involving minimal sample handling and no consumption of organic solvents. The affinity of the analytes toward five commercial SPME coatings was evaluated in univariate mode, and the best result in terms of analyte extraction was achieved using the divinylbenzene/carboxen/polydimethylsiloxane fiber. The variables affecting the performance of SPME analysis were optimized by the multivariate approach of experimental design and, in particular, using a central composite design (CCD). The optimal working conditions in terms of response values are the following: extraction temperature 40 °C, extraction time of 15 min and no addition of NaCl. Analyses were carried out by gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) in selected reaction monitoring (SRM) acquisition mode. The developed method was validated according to the guidelines issued by the Food and Drug Administration (FDA). The satisfactory performances reached in terms of linearity, sensitivity (LOQs between 0.01 and 0.1 μg/mL), matrix effect (68-121%), accuracy, and precision (inter-day values between -24% and +16% and in the range 3.3-28.4%, respectively) make the proposed protocol suitable to be adopted for quantification of these important biomarkers in urine samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Fish Oil Supplementation and Urinary Oxalate Excretion in Normal Subjects on a Low-oxalate Diet
Lange, Jessica N.; Mufarrij, Patrick W.; Easter, Linda; Knight, John; Holmes, Ross P.; Assimos, Dean G.
2014-01-01
OBJECTIVE To determine if fish oil supplementation reduces endogenous oxalate synthesis in healthy subjects. MATERIALS AND METHODS Fifteen healthy non–stone-forming adults participated in this study. Subjects first abstained from using vitamins, medications, or foods enriched in omega-3 fatty acids for 30 days. Next, they collected two 24-hour urine specimens while consuming a self-selected diet. Subjects consumed an extremely low-oxalate and normal-calcium diet for 5 days and collected 24-hour urine specimens on the last 3 days of this diet. Next, the subjects took 2 fish oil capsules containing 650-mg eicosapentaenoic acid and 450-mg docosahexaenoic acid twice daily for 30 days. They consumed a self-selected diet on days 1–25 and the controlled diet on days 26–30. Twenty-four-hour urine samples were collected on days 28–30. Excretion levels of urinary analytes including oxalate and glycolate were analyzed. RESULTS Although there was a significant reduction in urinary oxalate, magnesium, and potassium excretions and an increase in uric acid excretion during the controlled dietary phases compared with the self-selected diet, there were no significant differences in their excretion during controlled diet phases with and without fish oil supplementation. CONCLUSION These results suggest that fish oil supplementation does not reduce endogenous oxalate synthesis or urinary oxalate excretion in normal adults during periods of extremely low oxalate intake. However, these results do not challenge the previously described reduction in urinary oxalate excretion demonstrated in normal subjects consuming a moderate amount of oxalate in conjunction with fish oil. PMID:25102784
Multi-residue analysis of organic pollutants in hair and urine for matrices comparison.
Hardy, Emilie M; Duca, Radu C; Salquebre, Guillaume; Appenzeller, Brice M R
2015-04-01
Urine being currently the most classically used matrix for the assessment of human exposure to pesticides, a growing interest is yet observed in hair analysis for the detection of organic pollutants. The aim of the present work was to develop and to validate multi-residue analytical methods, as similar as possible, in order to determine pesticides and their metabolites in these two biological matrices despite their different nature. The list of parent compounds and their metabolites investigated here consisted of 56 compounds, including organochlorines, organophosphates, pyrethroids, carbamates, other pesticides and polychlorinated biphenyls (PCBs). Two different approaches were necessary for the analysis of non-polar compounds (mainly parents) on one hand and polar analytes (mainly metabolites) on the other hand. In the final procedure, extraction from hair was carried out with acetonitrile/water after sample decontamination and pulverization. Extract was split into two fractions, which were analyzed directly with solid phase microextraction (SPME) injection for non-polar compounds and after derivatization with liquid injection for polar compounds. In urine, non-polar compounds were analyzed directly using SPME. Polar compounds were analyzed after acidic hydrolysis, liquid-liquid extraction with acetonitrile-cyclohexane-ethyl acetate, derivatization and liquid injection. Analysis was performed with gas chromatography tandem mass spectrometry operating in negative chemical ionization (GC-MS/MS-NCI) for all the compounds (non-polar and polar) in the two matrices. In hair, limits of quantification (LOQ) ranged from 0.02 pg/mg for trifluralin to 5.5 pg/mg for diethylphosphate. In urine, LOQ ranged from 0.4 pg/mL for α-endosulfan to 4 ng/mL for dimethyldithiophosphate. The analysis of samples supplemented with standards and samples collected from an animal previously submitted to chronic exposure to pesticides confirmed that all the compounds were analyzable in both hair and urine. In addition, the levels of sensitivity reached with these methods were quite satisfactory with regard to previously published studies, and also considering the number of compounds investigated. Copyright © 2014. Published by Elsevier Ireland Ltd.
Chemical Analysis Results for Potable Water from ISS Expeditions 21 Through 25
NASA Technical Reports Server (NTRS)
Straub, John E., II; Plumlee, Debrah K.; Schultz, John R.; McCoy, J. Torin
2011-01-01
The Johnson Space Center Water and Food Analytical Laboratory (WAFAL) performed detailed ground-based analyses of archival water samples for verification of the chemical quality of the International Space Station (ISS) potable water supplies for Expeditions 21 through 25. Over a 14-month period the Space Shuttle visited the ISS on four occasions to complete construction and deliver supplies. The onboard supplies of potable water available for consumption by the Expeditions 21 to 25 crews consisted of Russian ground-supplied potable water, Russian potable water regenerated from humidity condensate, and US potable water recovered from urine distillate and condensate. Chemical archival water samples that were collected with U.S. hardware during Expeditions 21 to 25 were returned on Shuttle flights STS-129 (ULF3), STS-130 (20A), STS-131 (19A), and STS-132 (ULF4), as well as on Soyuz flights 19-23. This paper reports the analytical results for these returned potable water archival samples and their compliance with ISS water quality standards.
Gavra, Paul; Nguyen, Anne Q N; Beauregard, Natasha; Denault, André Y; Varin, France
2014-08-01
An analytical assay using liquid-liquid extraction and high-performance liquid chromatography with ultraviolet detection was developed for the quantification of total (conjugated and unconjugated) urinary concentrations of milrinone after the inhalation of a 5 mg dose in 15 cardiac patients undergoing cardiopulmonary bypass. Urine samples (700 μL) were extracted with ethyl-acetate and subsequently underwent acid back-extraction before and after deconjugation by mild acid hydrolysis. Milrinone was separated on a strong cation exchange analytical column. The mobile phase consisted of a constant mixture of acetonitrile:tetrahydrofurane-NaH2 PO4 buffer (40:60 v/v, pH 3.0). Thirteen calibration curves were linear in the concentration range of 31.25-4000 ng/mL, using olprinone as the internal standard (r(2) range 0.9911-0.9999, n = 13). Mean milrinone recovery and accuracy were respectively 85.2 ± 3.1% and ≥93%. Intra- and inter-day precisions (coefficients of variation) were ≤5% and ≤8%, respectively. Over a 24 h collection period, the cumulative urinary milrinone recovered from 15 patients was 26.1 ± 7.7% of the nominal 5 mg dose administered. The relative amount of milrinone glucuronic acid conjugate was negligible in the urine of patients undergoing cardiopulmonary bypass This method proved to be reliable, specific and accurate to determine the cumulative amount of total milrinone recovered in urine after inhalation. Copyright © 2014 John Wiley & Sons, Ltd.
Aturki, Zeineb; Fanali, Salvatore; Rocco, Anna
2016-10-01
A sensitive and rapid CZE-UV method was developed to determine drugs and their metabolites' presence in human urine. Ten drugs of abuse were analyzed including four amphetamines, cocaine, cocaethylene, heroin, morphine, 6-monoacetylmorphine, and 4-methylmethcathinone. An MSS (micelle to solvent stacking) approach was evaluated to enhance method sensitivity. This method considers composition of the micellar sample solution matrix and the injection time. Several analytical conditions influencing the resolution of the drugs mixture as pH and buffer concentration, organic solvent content, were also investigated. The base-line separation of all studied analytes in the same run was achieved within 18 min in an uncoated fused silica capillary (50 μm id × 60 cm) using a background solution containing 50 mM phosphate buffer pH 2.5 and 30% ACN v/v. Other experimental parameters such as applied voltage and capillary temperature were set up at 20 kV and 20°C, respectively. LOD values ranging between 15 and 75 ng/mL for all studied compounds were obtained. From a comparison with conventional CZE, the proposed method provides an increase of sensitivity (39- to 55-fold enhancement factor). Under optimal MSS-CZE conditions, good linearity was achieved (R 2 ≤ 0.9998). The method was finally applied to the analysis of urine samples spiked with a standard mixture after a sample pretreatment, reaching satisfactory recovery values. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Abushareeda, Wadha; Lyris, Emmanouil; Kraiem, Suhail; Wahaibi, Aisha Al; Alyazidi, Sameera; Dbes, Najib; Lommen, Arjen; Nielen, Michel; Horvatovich, Peter L; Alsayrafi, Mohammed; Georgakopoulos, Costas
2017-09-15
This paper presents the development and validation of a high-resolution full scan (FS) electron impact ionization (EI) gas chromatography coupled to quadrupole Time-of-Flight mass spectrometry (GC/QTOF) platform for screening anabolic androgenic steroids (AAS) in human urine samples. The World Antidoping Agency (WADA) enlists AAS as prohibited doping agents in sports, and our method has been developed to comply with the qualitative specifications of WADA to be applied for the detection of sports antidoping prohibited substances, mainly for AAS. The method also comprises of the quantitative analysis of the WADA's Athlete Biological Passport (ABP) endogenous steroidal parameters. The applied preparation of urine samples includes enzymatic hydrolysis for the cleavage of the Phase II glucuronide conjugates, generic liquid-liquid extraction and trimethylsilyl (TMS) derivatization steps. Tandem mass spectrometry (MS/MS) acquisition was applied on few selected ions to enhance the specificity and sensitivity of GC/TOF signal of few compounds. The full scan high resolution acquisition of analytical signal, for known and unknown TMS derivatives of AAS provides the antidoping system with a new analytical tool for the detection designer drugs and novel metabolites, which prolongs the AAS detection, after electronic data files' reprocessing. The current method is complementary to the respective liquid chromatography coupled to mass spectrometry (LC/MS) methodology widely used to detect prohibited molecules in sport, which cannot be efficiently ionized with atmospheric pressure ionization interface. Copyright © 2017 Elsevier B.V. All rights reserved.
Analysis of catecholamines in urine by unique LC/MS suitable ion-pairing chromatography.
Bergmann, Marianne L; Sadjadi, Seyed; Schmedes, Anne
2017-07-01
The catecholamines, epinephrine (E) and norepinephrine (NE) are small polar, hydrophilic molecules, posing significant challenges to liquid chromatography - tandem mass spectrometry (LC-MS/MS) method development. Specifically, these compounds show little retention on conventional reversed-phase liquid chromatography columns. This work presents development and validation of an LC-MS/MS method for determining catecholamines in urine, based on a new approach to ion-pairing chromatography (IPC), in which the ion-pairing reagent (IPR), 1-Heptane Sulfonic Acid (HSA), is added to the extracted samples instead of the mobile phases. A Hamilton STARlet workstation carried out the solid phase extraction of urine samples. The extracted samples were diluted with 60mmol/L HSA and injected on a Kinetex core-shell biphenyl column with conventional LC-MS/MS suitable mobile phases. Chromatographic separation of E and NE was achieved successfully with very stable retention times (RT). In 484 injections, the RTs were steady with a CV of less than ±4%. Furthermore, HSA was separated from E and NE, allowing HSA to be diverted to waste instead of entering the mass spectrometer ion chamber. The method was validated with good analytical performance, and even though the analysis for urinary catecholamines is increasingly being replaced by plasma free metanephrines in diagnosing pheochromocytomas, this work represents the application of a new analytical technique that can be transferred to other small polar molecules, that are difficult to chromatograph on traditional reversed phase columns. Copyright © 2017 Elsevier B.V. All rights reserved.
Murtada, Khaled; de Andrés, Fernando; Ríos, Angel; Zougagh, Mohammed
2018-04-20
Poly(styrene-co-divinylbenzene)-coated magnetic multiwalled carbon nanotube composite synthesized by in-situ high temperature combination and precipitation polymerization of styrene-co-divinylbenzene has been employed as a magnetic sorbent for the solid phase extraction of antidepressants in human urine samples. Fluoxetine, venlafaxine, citalopram and sertraline were, afterwards, separated and determined by capillary electrophoresis with diode array detection. The presence of magnetic multiwalled carbon nanotubes in native poly(styrene-co-divinylbenzene) not only simplified sample treatment but also enhanced the adsorption efficiencies, obtaining extraction recoveries higher than 89.5% for all analytes. Moreover, this composite can be re-used at least 10 times without loss of efficiency and limits of detection ranging from 0.014 to 0.041 μg mL -1 were calculated. Additionally, precision values ranging from 0.08 to 7.50% and from 0.21 to 3.05% were obtained for the responses and for the migration times of the analytes, respectively. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Strano-Rossi, Sabina; Molaioni, Francesco; Rossi, Francesca; Botrè, Francesco
2005-01-01
This paper describes a rapid gas chromatographic/mass spectrometric (GC/MS) screening method for the detection of drugs of abuse and/or their metabolites in urine. Synthetic stimulants, opiates, cocaine metabolites, cannabinoids--and specifically the acid metabolite of tetrahydrocannabinol (THC-COOH)--can be simultaneously extracted by a single liquid/liquid separation step, at alkaline pH, and assayed as trimethylsilyl derivatives by GC/MS in SIM (selected ion monitoring) mode. All the analytes show a good linearity (R2 > 0.99 for most of the considered substances) in the range 25-1000 ng/mL, with a good reproducibility of both the retention times (CV% <0.7) and the relative abundances of the characteristic diagnostic ions (CV% <13). The limit of detection (LOD) of the method is 25 ng/mL of target compound in human urine for most of the substances investigated, 3 ng/mL for THC-COOH, and 10 ng/mL for norbuprenorphine. Validation of the method allows its application to different fields of forensic analytical toxicology, including antidoping analysis.
Kriebel, Anita; Dörr, Claudia; Bandt, Susanne; Rist, Manuela; Roth, Alexander; Hummel, Eva; Kulling, Sabine; Hoffmann, Ingrid; Watzl, Bernhard
2016-01-01
Background The human metabolome is influenced by various intrinsic and extrinsic factors. A precondition to identify such biomarkers is the comprehensive understanding of the composition and variability of the metabolome of healthy humans. Sample handling aspects have an important impact on the composition of the metabolome; therefore, it is crucial for any metabolomics study to standardize protocols on sample collection, preanalytical sample handling, storage, and analytics to keep the nonbiological variability as low as possible. Objective The main objective of the KarMeN study is to analyze the human metabolome in blood and urine by targeted and untargeted metabolite profiling (gas chromatography-mass spectrometry [GC-MS], GC×GC-MS, liquid chromatography-mass spectrometry [LC-MS/MS], and1H nuclear magnetic resonance [NMR] spectroscopy) and to determine the impact of sex, age, body composition, diet, and physical activity on metabolite profiles of healthy women and men. Here, we report the outline of the study protocol with special regard to all aspects that should be considered in studies applying metabolomics. Methods Healthy men and women, aged 18 years or older, were recruited. In addition to a number of anthropometric (height, weight, body mass index, waist circumference, body composition), clinical (blood pressure, electrocardiogram, blood and urine clinical chemistry) and functional parameters (lung function, arterial stiffness), resting metabolic rate, physical activity, fitness, and dietary intake were assessed, and 24-hour urine, fasting spot urine, and plasma samples were collected. Standard operating procedures were established for all steps of the study design. Using different analytical techniques (LC-MS, GC×GC-MS,1H NMR spectroscopy), metabolite profiles of urine and plasma were determined. Data will be analyzed using univariate and multivariate as well as predictive modeling methods. Results The project was funded in 2011 and enrollment was carried out between March 2012 and July 2013. A total of 301 volunteers were eligible to participate in the study. Metabolite profiling of plasma and urine samples has been completed and data analysis is currently underway. Conclusions We established the KarMeN study applying a broad set of clinical and physiological examinations with a high degree of standardization. Our experimental approach of combining scheduled timing of examinations and sampling with the multiplatform approach (GC×GC-MS, GC-MS, LC-MS/MS, and1H NMR spectroscopy) will enable us to differentiate between current and long-term effects of diet and physical activity on metabolite profiles, while enabling us at the same time to consider confounders such as age and sex in the KarMeN study. Trial Registration German Clinical Trials Register DRKS00004890; https://drks-neu.uniklinik-freiburg.de/drks_web/navigate.do? navigationId=trial.HTML&TRIAL_ID=DRKS00004890 (Archived by WebCite at http://www.webcitation.org/6iyM8dMtx) PMID:27421387
Hens, Koen; Berth, Mario; Armbruster, Dave; Westgard, Sten
2014-07-01
Six Sigma metrics were used to assess the analytical quality of automated clinical chemistry and immunoassay tests in a large Belgian clinical laboratory and to explore the importance of the source used for estimation of the allowable total error. Clinical laboratories are continually challenged to maintain analytical quality. However, it is difficult to measure assay quality objectively and quantitatively. The Sigma metric is a single number that estimates quality based on the traditional parameters used in the clinical laboratory: allowable total error (TEa), precision and bias. In this study, Sigma metrics were calculated for 41 clinical chemistry assays for serum and urine on five ARCHITECT c16000 chemistry analyzers. Controls at two analyte concentrations were tested and Sigma metrics were calculated using three different TEa targets (Ricos biological variability, CLIA, and RiliBÄK). Sigma metrics varied with analyte concentration, the TEa target, and between/among analyzers. Sigma values identified those assays that are analytically robust and require minimal quality control rules and those that exhibit more variability and require more complex rules. The analyzer to analyzer variability was assessed on the basis of Sigma metrics. Six Sigma is a more efficient way to control quality, but the lack of TEa targets for many analytes and the sometimes inconsistent TEa targets from different sources are important variables for the interpretation and the application of Sigma metrics in a routine clinical laboratory. Sigma metrics are a valuable means of comparing the analytical quality of two or more analyzers to ensure the comparability of patient test results.
NASA Astrophysics Data System (ADS)
Hoang, Khoa; Pophristic, Milan; Horan, Andrew J.; Johnston, Murray V.; McEwen, Charles N.
2016-10-01
First results are reported using a simple, fast, and reproducible matrix-assisted ionization (MAI) sample introduction method that provides substantial improvements relative to previously published MAI methods. The sensitivity of the new MAI methods, which requires no laser, high voltage, or nebulizing gas, is comparable to those reported for MALDI-TOF and n-ESI. High resolution full acquisition mass spectra having low chemical background are acquired from low nanoliters of solution using only a few femtomoles of analyte. The limit-of-detection for angiotensin II is less than 50 amol on an Orbitrap Exactive mass spectrometer. Analysis of peptides, including a bovine serum albumin digest, and drugs, including drugs in urine without a purification step, are reported using a 1 μL zero dead volume syringe in which only the analyte solution wetting the walls of the syringe needle is used in the analysis.
Ezekiel, Chibundu N; Warth, Benedikt; Ogara, Isaac M; Abia, Wilfred A; Ezekiel, Victoria C; Atehnkeng, Joseph; Sulyok, Michael; Turner, Paul C; Tayo, Grace O; Krska, Rudolf; Bandyopadhyay, Ranajit
2014-05-01
A pilot, cross-sectional, correlational study was conducted in eight rural communities in northern Nigeria to investigate mycotoxin exposures in 120 volunteers (19 children, 20 adolescents and 81 adults) using a modern LC-MS/MS based multi-biomarker approach. First morning urine samples were analyzed and urinary biomarker levels correlated with mycotoxin levels in foods consumed the day before urine collection. A total of eight analytes were detected in 61/120 (50.8%) of studied urine samples, with ochratoxin A, aflatoxin M1 and fumonisin B1 being the most frequently occurring biomarkers of exposure. These mycotoxin biomarkers were present in samples from all age categories, suggestive of chronic (lifetime) exposures. Rough estimates of mycotoxin intake suggested some exposures were higher than the tolerable daily intake. Overall, rural consumer populations from Nasarawa were more exposed to several mixtures of mycotoxins in their diets relative to those from Kaduna as shown by food and urine biomarker data. This study has shown that mycotoxin co-exposure may be a major public health challenge in rural Nigeria; this calls for urgent intervention. Copyright © 2014 Elsevier Ltd. All rights reserved.
Lee, Tien Ping; Saad, Bahruddin; Khayoon, Wejdan Shakir; Salleh, Baharuddin
2012-01-15
A simple, environmental friendly and selective sample preparation technique employing porous membrane protected micro-solid phase extraction (μ-SPE) loaded with molecularly imprinted polymer (MIP) for the determination of ochratoxin A (OTA) is described. After the extraction, the analyte was desorbed using ultrasonication and was analyzed using high performance liquid chromatography. Under the optimized conditions, the detection limits of OTA for coffee, grape juice and urine were 0.06 ng g(-1), 0.02 and 0.02 ng mL(-1), respectively while the quantification limits were 0.19 ng g(-1), 0.06 and 0.08 ng mL(-1), respectively. The recoveries of OTA from coffee spiked at 1, 25 and 50 ng g(-1), grape juice and urine samples at 1, 25 and 50 ng mL(-1) ranged from 90.6 to 101.5%. The proposed method was applied to thirty-eight samples of coffee, grape juice and urine and the presence of OTA was found in eighteen samples. The levels found, however, were all below the legal limits. Copyright © 2011 Elsevier B.V. All rights reserved.
Cheng, Annie; Kirby, James E
2014-03-01
To evaluate the performance of the Hologic Gen-Probe (San Diego, CA) PANTHER system. The performance of PANTHER was compared with the Hologic Gen-Probe TIGRIS and/or Roche (Indianapolis, IN) COBAS AMPLICOR systems through testing of patient specimens and the spiked-urine matrix. After discrepant resolution, PANTHER demonstrated a 99.3% (95% confidence interval [CI], 96.0%-99.9%) positive and 100% (98.5%-100.0%) negative agreement for Chlamydia trachomatis (CT) and 100% (96.6%-100.0%) positive and 100% (98.6%-100.0%) negative agreement for Neisseria gonorrhoeae (NG) for all male, female, unsexed, and NG-spiked female urine specimens combined. For other specimen types collectively, the PANTHER demonstrated 100% (95% CI, 90.6%-100.0%) positive and 100% (88.3%-100.0%) negative agreement for CT and 90.9% (62.8%-98.4%) positive and 100% (93.5%-100.0%) negative agreement for NG. Analytical sensitivity of the PANTHER in urine matrix was similar to the TIGRIS system. The PANTHER system provides an excellent new addition to options for detecting CT and NG, is appropriate for testing urine samples, and will facilitate high-throughput testing in the clinical laboratory.
Bal, Dominika; Gradowska, Wanda; Gryff-Keller, Adam
2002-06-15
Determination of the absolute configuration of some metabolites in body fluids is important for the diagnosis of some inborn errors of metabolism. Presently available methods of such determinations are tedious and usually require highly specialized instrumentation. In this work, an alternative method, based on high-resolution nuclear magnetic resonance spectroscopy in the presence of the chiral lanthanide shift reagent as an auxiliary additive, has been proposed (NMR/LSR). The method involves the lineshape analysis of a chosen multiplet of the one-dimensional 1H NMR spectrum or application of the two-dimensional 1H-13C correlation spectroscopy (HSQC). In order to confirm the resonance assignments and to boost the signal-noise ratio, the addition of an amount of racemic analyte to the urine sample is recommended. The entire procedure is simple in application and demands minimal or no preprocessing of urine samples. The effectiveness of the method has been confirmed by finding the expected forms of 2-hydroxyglutaric acid and 5-oxoproline in the urine samples of an independently diagnosed patient with 2-D-hydroxyglutaric aciduria and 5-L-oxoprolinuria, respectively.
Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method
Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, MahmoudReza; Karami-Osboo, Rouhollah
2013-01-01
Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 μL of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase containing enriched analyte was dissolved in acetonitrile and an aliquot of this solution injected into the HPLC system for analysis. Development of DLLME procedure includes optimization of some important parameters such as kind and volume of extraction and disperser solvent, pH and salt addition. The proposed method has good linearity in the range of 0.02-4.5 μg mL-1 and low detection limit (13.1 ng mL-1). The repeatability of the method, expressed as relative standard deviation was 4.9% (n = 3). This method has also been applied to the analysis of real urine samples with satisfactory relative recoveries in the range of 91.6-101.0%. PMID:24250605
Matczuk, Magdalena; Foteeva, Lidia S; Jarosz, Maciej; Galanski, Markus; Keppler, Bernhard K; Hirokawa, Takeshi; Timerbaev, Andrei R
2014-06-06
Transient isotachophoresis (tITP) is a versatile sample preconcentration technique that uses ITP to focus electrically charged analytes at the initial stage of CE analysis. However, according to the ruling principle of tITP, uncharged analytes are beyond its capacity while being separated and detected by micellar electrokinetic chromatography (MEKC). On the other hand, when these are charged micelles that undergo the tITP focusing, one can anticipate the concentration effect, resulting from the formation of transient micellar stack at moving sample/background electrolyte (BGE) boundary, which increasingly accumulates the analytes. This work expands the enrichment potential of tITP for MEKC by demonstrating the quantitative analysis of uncharged metal-based drugs from highly saline samples and introducing to the BGE solution anionic surfactants and buffer (terminating) co-ions of different mobility and concentration to optimize performance. Metallodrugs of assorted lipophilicity were chosen so as to explore whether their varying affinity toward micelles plays the role. In addition to altering the sample and BGE composition, optimization of the detection capability was achieved due to fine-tuning operational variables such as sample volume, separation voltage and pressure, etc. The results of optimization trials shed light on the mechanism of micellar tITP and render effective determination of selected drugs in human urine, with practical limits of detection using conventional UV detector. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Semenistaya, E. N.; Virus, E. D.; Rodchenkov, G. M.
2009-04-01
the possibility of selective determination of testosterone and epitestosterone glucuronides in urine by high-performance liquid chromatography/high-resolution mass spectrometry using solid phase microextraction on a meps cartridge was studied. the effect of the biological matrix on the spectra of conjugated steroids can be taken into account by using the spectra of conjugates recorded for urine samples after hydrolysis as reference spectra. the conditions of fragmentation in the ion source were optimized for separate analytes. this method was used for analyzing real samples with different testosterone/epitestosterone ratios. variations in conjugate contents and qualitative changes in the steroid profile of endogenic compounds were observed.
Chung, Y L; Liu, J T; Lin, C H
2001-08-15
The analytical profiles for 3,4-methylenedioxymethamphetamine (3,4-MDMA) and related amphetamines in urine samples are described for non-aqueous capillary electrophoresis-fluorescence spectroscopy. 3,4-MDMA was detected and identified on-line, using a cryogenic molecular fluorescence technique at 77 K. Under optimized conditions, baseline separation of the selected compounds was achieved in less than 12 min. Precision was evaluated by measuring the repeatability and intermediate precision of the migration times and corrected peak areas. The non-aqueous CE separation conditions and the spectral characteristics of 3,4-MDMA with respect to solvent and temperature effects are also discussed.
la Marca, Giancarlo; Rizzo, Cristiano
2011-01-01
The analysis of organic acids in urine is commonly included in routine procedures for detecting many inborn errors of metabolism. Many analytical methods allow for both qualitative and quantitative determination of organic acids, mainly in urine but also in plasma, serum, whole blood, amniotic fluid, and cerebrospinal fluid. Liquid-liquid extraction and solid-phase extraction using anion exchange or silica columns are commonly employed approaches for sample treatment. Before analysis can be carried out using gas chromatography-mass spectrometry, organic acids must be converted into more thermally stable, volatile, and chemically inert forms, mainly trimethylsilyl ethers, esters, or methyl esters.
Aulbach, Adam D; Schultze, Eric; Tripathi, Niraj K; Hall, Robert L; Logan, Michael R; Meyer, Denny J
2015-06-01
Urinalysis data in preclinical toxicology studies can be influenced by preanalytic and analytic factors which have the potential to confound interpretation. There is a paucity of information regarding positive reagent strip urinary blood reactions in healthy nonhuman primates (NHP) and Beagle dogs used in preclinical toxicology studies. The objectives were (1) to establish historical control data for reagent strip urinary blood reactions in healthy NHP and Beagle dogs, (2) to determine the incidence of positive urinary blood reactions during predose and dosing phases, and (3) to determine if collection practice was a relevant parameter. Historical control data from 2 institutions in the biopharmaceutical industry were retrospectively analyzed for reagent strip urinary blood reactions in healthy NHP and Beagles. The incidence of positive results between the 2 institutions with different urine collection practices and between males and females was compared. The incidence of positive urinary blood reactions in NHP was comparable between institutions (≤ 14% in males; ≤ 33% in females), while the incidence of positive urinary blood reactions in Beagles was more variable (≤ 77% in males; ≤ 69% in females), and higher in females during the dosing phase. Positive urinary blood results that could potentially be misinterpreted as toxicologically relevant were identified in healthy NHP and Beagles during predose and dosing phases. Different incidences of positive results between the 2 institutions were likely related to collection practices. Strategies to reduce feces and food contamination of collected urine samples should help minimize false-positive urinary blood reactions. © 2015 American Society for Veterinary Clinical Pathology.
Cho, Sung-Hee; Lee, Sun-Kyung; Kim, Chong Hyeak
2018-05-01
Polycyclic aromatic hydrocarbons (PAHs), organic compounds formed by at least two condensed aromatic rings, are ubiquitous environmental pollutants that are produced by incomplete combustion of organic materials. PAHs have been classified as carcinogenIC to humans by the International Agency for Research on Cancer, because they can bind to DNA, causing mutations. Therefore, the levels of PAHs in human urine can be used as an indicator for potential carcinogenesis and cell mutation. An analytical method was developed for the accurate measurement of PAHs in urine using high-resolution gas chromatography-mass spectrometry. Urine samples were extracted by an Oasis HLB extraction cartridge after enzymatic hydrolysis with a β-glucuronidase/arylsulfatase cocktail. The 18 PAHs were separated using an Agilent DB-5 MS capillary column (30 m × 0.25 mm, 0.25 μm) and monitored by time-of-flight mass spectrometry. Under the optimized method, the linearity of calibration curves was >0.994. The limits of detection at a signal-to-noise ratio of 3 were 10-100 ng/L. The coefficients of variation were in the range of 0.4-9.0%. The present method was highly accurate for simultaneous determination of 18 PAHs in human urine and could be applied to monitoring and biomedical investigations to check exposure of PAHs. Copyright © 2017 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raml, Reingard; Rumpler, Alice; Goessler, Walter
2007-08-01
Over the last 6 years, much work on arsenic species in urine samples has been directed toward the determination of the reduced dimethylated arsenic species, DMA(III), because of its high toxicity and perceived key role in the metabolism of inorganic arsenic. Recent work, however, has suggested that DMA(III) may at times have been misidentified because its chromatographic properties can be similar to those of thio-dimethylarsinate (thio-DMA). We analyzed by HPLC-ICPMS (inductively coupled plasma mass spectrometry) urine samples from 75 arsenic-exposed women from Bangladesh with total arsenic concentrations ranging from 8 to 1034 {mu}g As/L and found that thio-DMA was presentmore » in 44% of the samples at concentrations ranging mostly from trace amounts to 24 {mu}g As/L (one sample contained 123 {mu}g As/L). Cytotoxicity testing with HepG2 cells derived from human hepatocarcinoma indicated that thio-DMA was about 10-fold more cytotoxic than dimethylarsinate (DMA). The widespread occurrence of thio-DMA in urine from these arsenic-exposed women suggests that this arsenical may also be present in other urine samples and has so far escaped detection. The work highlights the need for analytical methods providing specific determinations of arsenic compounds in future studies on arsenic metabolism and toxicology.« less
Rodríguez, J; Castañeda, G; Muñoz, L
2013-01-15
This work reports the validation of a high precision and accuracy method for the simultaneous determination of letrozole, citalopram and their metabolites in urine by high performance liquid chromatography with fluorescence detection. Dilution (urine:mobile phase, 1:2, v/v) was the only sample preparation step. The separation was carried out in a Kromasil C(18) (150mm×4.6mm) column, and the mobile phase was phosphate buffer 80mM (pH 3.0) and acetonitrile (65:35, v/v) at a flow rate of 1.0mL/min. The analytes were detected at 295nm after excitation at 230nm. Linearity was observed in the range of 1.0-1000ng/mL for letrozole and its metabolite and 2.5-1000ng/mL for citalopram and their metabolites, with limits of detection and quantification between 0.09-1.0 and 0.27-1.65ng/mL, respectively. The precisions were satisfactory with RSDs between 0.17 and 5.71%. The accuracy was studied by spiking three urines from healthy female volunteers, and the recoveries were from 85 to 103%. The method was applied to urine samples from women under treatment for breast cancer and depression diseases. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ahmed, Hytham M.; Ebeid, Wael B.
2015-05-01
Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200 ng/ml respectively and recovery was >98% (n = 5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000 IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period.
Determination of urine ionic composition with potentiometric multisensor system.
Yaroshenko, Irina; Kirsanov, Dmitry; Kartsova, Lyudmila; Sidorova, Alla; Borisova, Irina; Legin, Andrey
2015-01-01
The ionic composition of urine is a good indicator of patient's general condition and allows for diagnostics of certain medical problems such as e.g., urolithiasis. Due to environmental factors and malnutrition the number of registered urinary tract cases continuously increases. Most of the methods currently used for urine analysis are expensive, quite laborious and require skilled personnel. The present work deals with feasibility study of potentiometric multisensor system of 18 ion-selective and cross-sensitive sensors as an analytical tool for determination of urine ionic composition. In total 136 samples from patients of Urolithiasis Laboratory and healthy people were analyzed by the multisensor system as well as by capillary electrophoresis as a reference method. Various chemometric approaches were implemented to relate the data from electrochemical measurements with the reference data. Logistic regression (LR) was applied for classification of samples into healthy and unhealthy producing reasonable misclassification rates. Projection on Latent Structures (PLS) regression was applied for quantitative analysis of ionic composition from potentiometric data. Mean relative errors of simultaneous prediction of sodium, potassium, ammonium, calcium, magnesium, chloride, sulfate, phosphate, urate and creatinine from multisensor system response were in the range 3-13% for independent test sets. This shows a good promise for development of a fast and inexpensive alternative method for urine analysis. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Yuanchao; Wu, Qiong; Cheng, Meirong; Cai, Cheng
2011-04-15
A novel method for simultaneous determination of atenolol, metoprolol and esmolol was proposed by capillary electrophoresis (CE) separation and electrochemiluminescence (ECL) detection. Poly-β-cyclodextrin (Poly-β-CD) was used as an additive in the running buffer to improve the separation of three analytes. The conditions for CE separation, ECL detection and effect of Poly-β-CD were investigated in detail. The three β-blockers with very similar structures were well separated and detected under the optimum conditions. The linear ranges of the standard solution for atenolol and esmolol were 2.5-125 μmol/L with a detection limit (S/N=3) of 0.5 μmol/L, and for metoprolol was 0.5-25 μmol/L with a detection limit of 0.1 μmol/L. For three β-blockers from spiked aqueous and urine samples, the accuracy and precision including intraday and interday experiments were performed by calculating the recovery, the relative standard deviations of the ECL intensity and the migration time, respectively. The developed method was applied to the determination of metoprolol content in commercial pharmaceutical, and the analytical results are in good agreement with the nominal value with recoveries in the range of 98.7-105%. The proposed method was also applied to the monitoring of pharmacokinetics for metoprolol in human body. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.
Nandrolone: a multi-faceted doping agent.
Hemmersbach, Peter; Grosse, Joachim
2010-01-01
Nandrolone or nortestosterone, an anabolic-androgenic steroid, has been prohibited by doping control regulations for more than 30 years. Although its main metabolism in the human body was already known at that time, and detection of its misuse by gas or liquid chromatographic separation with mass spectrometric detection is straightforward, many interesting aspects regarding this doping agent have appeared since.Over the years, nandrolone preparations have kept their position among the prohibited substances that are most frequently detected in WADA-accredited laboratories. Their forms of application range from injectable fatty acid esters to orally administered nandrolone prohormones. The long detection window for nandrolone ester preparations and the appearance of orally available nandrolone precursors have changed the pattern of misuse.At the same time, more refined analytical methods with lowered detection limits led to new insights into the pharmacology of nandrolone and revelation of its natural production in the body.Possible contamination of nutritional supplements with nandrolone precursors, interference of nandrolone metabolism by other drugs and rarely occurring critical changes during storage of urine samples have to be taken into consideration when interpreting an analytical finding.A set of strict identification criteria, including a threshold limit, is applied to judge correctly an analytical finding of nandrolone metabolites. The possible influence of interfering drugs, urine storage or natural production is taken into account by applying appropriate rules and regulations.
Automated color classification of urine dipstick image in urine examination
NASA Astrophysics Data System (ADS)
Rahmat, R. F.; Royananda; Muchtar, M. A.; Taqiuddin, R.; Adnan, S.; Anugrahwaty, R.; Budiarto, R.
2018-03-01
Urine examination using urine dipstick has long been used to determine the health status of a person. The economical and convenient use of urine dipstick is one of the reasons urine dipstick is still used to check people health status. The real-life implementation of urine dipstick is done manually, in general, that is by comparing it with the reference color visually. This resulted perception differences in the color reading of the examination results. In this research, authors used a scanner to obtain the urine dipstick color image. The use of scanner can be one of the solutions in reading the result of urine dipstick because the light produced is consistent. A method is required to overcome the problems of urine dipstick color matching and the test reference color that have been conducted manually. The method proposed by authors is Euclidean Distance, Otsu along with RGB color feature extraction method to match the colors on the urine dipstick with the standard reference color of urine examination. The result shows that the proposed approach was able to classify the colors on a urine dipstick with an accuracy of 95.45%. The accuracy of color classification on urine dipstick against the standard reference color is influenced by the level of scanner resolution used, the higher the scanner resolution level, the higher the accuracy.
Sempio, Cristina; Scheidweiler, Karl B; Barnes, Allan J; Huestis, Marilyn A
2018-03-01
Prolonged urinary cannabinoid excretion in chronic frequent cannabis users confounds identification of recent cannabis intake that may be important in treatment, workplace, clinical, and forensic testing programs. In addition, differentiation of synthetic Δ9-tetrahydrocannabinol (THC) intake from cannabis plant products might be an important interpretive issue. THC, 11-hydroxy-THC (11-OH-THC) and 11-nor-9-carboxy-THC (THCCOOH) urine concentrations were evaluated during previous controlled cannabis administration studies following tandem alkaline/E. coli β-glucuronidase hydrolysis. We optimized recombinant β-glucuronidase enzymatic urinary hydrolysis before simultaneous liquid chromatography tandem mass spectrometry (LC-MS/MS) quantification of THC, 11-OH-THC, THCCOOH, cannabidiol (CBD), cannabinol (CBN), cannabigerol (CBG), tetrahydrocannabivarin (THCV) and 11-nor-9-carboxy-THCV (THCVCOOH) in urine. Enzyme amount, incubation time and temperature, buffer molarity and pH were optimized using pooled urine samples collected during a National Institute on Drug Abuse, Institutional Review Board-approved clinical study. Optimized cannabinoid hydrolysis with recombinant β-glucuronidase was achieved with 2000 IU enzyme, 2 M pH 6.8 sodium phosphate buffer, and 0.2 mL urine at 37°C for 16 h. The LC-MS/MS quantification method for hydrolyzed urinary cannabinoids was validated per the Scientific Working Group on Toxicology guidelines. Linear ranges were 1-250 μg/L for THC and CBG, 2-250 μg/L for 11-OH-THC, CBD, CBN, THCV and THCVCOOH, and 1-500 μg/L for THCCOOH. Inter-batch analytical bias was 92.4-112.4%, imprecision 4.4-9.3% CV (n = 25), extraction efficiency 44.3-97.1% and matrix effect -29.6 to 1.8% (n = 10). The method was utilized to analyze urine specimens collected during our controlled smoked, vaporized, and edible cannabis administration study to improve interpretation of urine cannabinoid test results. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Hara, Matthew J.; Carter, Jennifer C.; Maclellan, Jay A.
2011-08-01
In the event of an accidental or intentional release of radionuclides into a populated area, three things must occur in a timely manner: food and drinking water supplies must be determined to be safe to eat / drink, civilians and/or military personnel must be surveyed to ensure that they do not have external contamination, and they must be screened to ensure that significant ingestion or inhalation of radionuclides has not occurred (this paper is concerned with the latter). In the event of such a disaster, the volume of radiobioassays to be performed would be tremendous. If the event released significantmore » levels of β- or α-emitting radionuclides, in vivo assays would be ineffective. Therefore, highly efficient and rapid analytical methods for radionuclide detection from submitted spot urine samples (≤ 50 mL) would be required. At present, the quantitative determination of α-emitting radionuclides from urine samples is highly labor intensive, and requires significant sample preparation and analysis time. Sorbent materials that provide effective collection and enable rapid assay could significantly streamline the radioanalytical process. We have demonstrated the use of paramagnetic nanoparticles as a novel class of extracting media for four α-emitting radionuclides of concern (Po, Ra, Am, and U) from chemically unmodified and pH 2 human urine. Herein the initial experimental sorption results are presented along with a novel method that utilizes paramagnetic nanoparticles for the extraction of radionuclides from unmodified human urine followed by the magnetic field-induced collection of the particles for subsequent α-counting-source preparation. Additionally, we construct a versatile human dose model that determines the detector count times required to estimate internal human dose at specific protective action thresholds. The model provides a means to assess a method’s detection capabilities and use fundamental health physics parameters and actual experimental data as core variables. The modeling shows that with effective sorbent materials, rapid screening for internalized α-emitters is possible from a 50 mL spot urine sample volume collected within one week of exposure/intake.« less
Stefanelli, Fabio; Pesci, Federica Giorgia; Giusiani, Mario; Chericoni, Silvio
2018-04-01
A novel aqueous in situ derivatization procedure with propyl chloroformate (PCF) for the simultaneous, quantitative analysis of Δ 9 -tetrahydrocannabinol (THC), 11-hydroxy-Δ 9 -tetrahydrocannabinol (OH-THC) and 11-nor-Δ 9 -tetrahydrocannabinol-carboxylic acid (THC-COOH) in human blood and urine is proposed. Unlike current methods based on the silylating agent [N,O-bis(trimethylsilyl)trifluoroacetamide] added in an anhydrous environment, this new proposed method allows the addition of the derivatizing agent (propyl chloroformate, PCF) directly to the deproteinized blood and recovery of the derivatives by liquid-liquid extraction. This novel method can be also used for hydrolyzed urine samples. It is faster than the traditional method involving a derivatization with trimethyloxonium tetrafluoroborate. The analytes are separated, detected and quantified by gas chromatography-mass spectrometry in selected ion monitoring mode (SIM). The method was validated in terms of selectivity, capacity of identification, limits of detection (LOD) and quantification (LOQ), carryover, linearity, intra-assay precision, inter-assay precision and accuracy. The LOD and LOQ in hydrolyzed urine were 0.5 and 1.3 ng/mL for THC and 1.2 and 2.6 ng/mL for THC-COOH, respectively. In blood, the LOD and LOQ were 0.2 and 0.5 ng/mL for THC, 0.2 and 0.6 ng/mL for OH-THC, and 0.9 and 2.4 ng/mL for THC-COOH, respectively. This method was applied to 35 urine samples and 50 blood samples resulting to be equivalent to the previously used ones with the advantage of a simpler method and faster sample processing time. We believe that this method will be a more convenient option for the routine analysis of cannabinoids in toxicological and forensic laboratories. Copyright © 2017 John Wiley & Sons, Ltd.
Ko, Dae-Hyun; Ji, Misuk; Kim, Sollip; Cho, Eun-Jung; Lee, Woochang; Yun, Yeo-Min; Chun, Sail; Min, Won-Ki
2016-01-01
The results of urine sediment analysis have been reported semiquantitatively. However, as recent guidelines recommend quantitative reporting of urine sediment, and with the development of automated urine sediment analyzers, there is an increasing need for quantitative analysis of urine sediment. Here, we developed a protocol for urine sediment analysis and quantified the results. Based on questionnaires, various reports, guidelines, and experimental results, we developed a protocol for urine sediment analysis. The results of this new protocol were compared with those obtained with a standardized chamber and an automated sediment analyzer. Reference intervals were also estimated using new protocol. We developed a protocol with centrifugation at 400 g for 5 min, with the average concentration factor of 30. The correlation between quantitative results of urine sediment analysis, the standardized chamber, and the automated sediment analyzer were generally good. The conversion factor derived from the new protocol showed a better fit with the results of manual count than the default conversion factor in the automated sediment analyzer. We developed a protocol for manual urine sediment analysis to quantitatively report the results. This protocol may provide a mean for standardization of urine sediment analysis.
Albermann, M E; Musshoff, F; Madea, B
2012-01-01
Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are powerful markers for alcohol intake and abuse. Several analytical procedures for the quantification of EtG and EtG in serum and urine have been developed so far. Many of the published methods show limits of detections (LODs) or limits of quantifications (LOQs) for EtG in urine within the range of 0.1 mg/L or higher. Since this is the actual cutoff value for proving abstinence in Germany, problems may occur if urine samples are highly diluted. In this paper, the validation of a highly sensitive, fast and simple LC-MS-MS for the determination of EtG and EtS in urine is described. The calibration curves for EtG and EtS is linear over the whole range (0.025-2.0 mg/L). Very low detection limits can be achieved (LOD: EtG 0.005 mg/L, EtS 0.005 mg/L; and LOQ: EtG 0.019 mg/L, EtS 0.015 mg/L). All data for selectivity, precision and accuracy, recovery, as well as for the processed sample and the freeze/thaw stability, comply with the guidelines of the German Society of Toxicological and Forensic Chemistry. Strong matrix-related effects can be compensated for by using an internal standard. Finally, the applicability of the procedure is proven by analysis of 87 human urine samples and by successful participation in interlaboratory comparison tests. © The Author [2011]. Published by Oxford University Press. All rights reserved.
Gray, Nicola; Lewis, Matthew R; Plumb, Robert S; Wilson, Ian D; Nicholson, Jeremy K
2015-06-05
A new generation of metabolic phenotyping centers are being created to meet the increasing demands of personalized healthcare, and this has resulted in a major requirement for economical, high-throughput metabonomic analysis by liquid chromatography-mass spectrometry (LC-MS). Meeting these new demands represents an emerging bioanalytical problem that must be solved if metabolic phenotyping is to be successfully applied to large clinical and epidemiological sample sets. Ultraperformance (UP)LC-MS-based metabolic phenotyping, based on 2.1 mm i.d. LC columns, enables comprehensive metabolic phenotyping but, when employed for the analysis of thousands of samples, results in high solvent usage. The use of UPLC-MS employing 1 mm i.d. columns for metabolic phenotyping rather than the conventional 2.1 mm i.d. methodology shows that the resulting optimized microbore method provided equivalent or superior performance in terms of peak capacity, sensitivity, and robustness. On average, we also observed, when using the microbore scale separation, an increase in response of 2-3 fold over that obtained with the standard 2.1 mm scale method. When applied to the analysis of human urine, the 1 mm scale method showed no decline in performance over the course of 1000 analyses, illustrating that microbore UPLC-MS represents a viable alternative to conventional 2.1 mm i.d. formats for routine large-scale metabolic profiling studies while also resulting in a 75% reduction in solvent usage. The modest increase in sensitivity provided by this methodology also offers the potential to either reduce sample consumption or increase the number of metabolite features detected with confidence due to the increased signal-to-noise ratios obtained. Implementation of this miniaturized UPLC-MS method of metabolic phenotyping results in clear analytical, economic, and environmental benefits for large-scale metabolic profiling studies with similar or improved analytical performance compared to conventional UPLC-MS.
Use of multiple colorimetric indicators for paper-based microfluidic devices.
Dungchai, Wijitar; Chailapakul, Orawon; Henry, Charles S
2010-08-03
We report here the use of multiple indicators for a single analyte for paper-based microfluidic devices (microPAD) in an effort to improve the ability to visually discriminate between analyte concentrations. In existing microPADs, a single dye system is used for the measurement of a single analyte. In our approach, devices are designed to simultaneously quantify analytes using multiple indicators for each analyte improving the accuracy of the assay. The use of multiple indicators for a single analyte allows for different indicator colors to be generated at different analyte concentration ranges as well as increasing the ability to better visually discriminate colors. The principle of our devices is based on the oxidation of indicators by hydrogen peroxide produced by oxidase enzymes specific for each analyte. Each indicator reacts at different peroxide concentrations and therefore analyte concentrations, giving an extended range of operation. To demonstrate the utility of our approach, the mixture of 4-aminoantipyrine and 3,5-dichloro-2-hydroxy-benzenesulfonic acid, o-dianisidine dihydrochloride, potassium iodide, acid black, and acid yellow were chosen as the indicators for simultaneous semi-quantitative measurement of glucose, lactate, and uric acid on a microPAD. Our approach was successfully applied to quantify glucose (0.5-20 mM), lactate (1-25 mM), and uric acid (0.1-7 mM) in clinically relevant ranges. The determination of glucose, lactate, and uric acid in control serum and urine samples was also performed to demonstrate the applicability of this device for biological sample analysis. Finally results for the multi-indicator and single indicator system were compared using untrained readers to demonstrate the improvements in accuracy achieved with the new system. 2010 Elsevier B.V. All rights reserved.
Cetin, Sevil Müge; Atmaca, Sedef
2004-03-26
A simple and reliable high-performance liquid chromatographic (HPLC) method with UV-Vis detection has been developed and validated for the determination of vigabatrin (VG) in human plasma and urine. The samples were pre-column derivatizated with 1,2-naphthoquinone-4-sulphonic acid sodium salt (NQS). A good chromatographic separation was achieved on a C18 column with a mobile phase consisting of acetonitrile and 10 mM orthophosphoric acid (pH 2.5) gradient elution. Tranexamic acid was used as an internal standard (I.S.). The method was linear over the concentration range of 0.8-30.0 microg/ml for both samples. The method is precise (relative standard deviation (R.S.D.) <9.13%) and accurate (relative mean error (RME) <-8.75%); analytical recoveries were 81.07% for plasma and 83.05% for urine. The assay was applied to pharmacokinetic study in a healthy volunteer after a single oral administration of 1 g of vigabatrin.
Bisphenol A levels in human urine.
Matsumoto, Akiko; Kunugita, Naoki; Kitagawa, Kyoko; Isse, Toyohi; Oyama, Tsunehiro; Foureman, Gary L; Morita, Masatoshi; Kawamoto, Toshihiro
2003-01-01
The estrogenic effects of bisphenol A (BPA) have been reported in human cells (E-screen assays) and in (italic)in vivo(/italic) studies of rodents, although the latter reports remain controversial, as do the exposure levels and adverse health effects of BPA in humans. In this study we report on an analytical high-performance liquid chromatography/fluorescence method for BPA and its conjugate in human urine and on the application of this method in two student cohorts. Urine, along with information on smoking, alcohol intake, and coffee/tea consumption, was collected in two different years from two different groups of university students, 50 in 1992 and 56 in 1999. Overall, the urinary BPA levels in the students in 1992 were significantly higher than were those in 1999. The BPA levels were also positively correlated with coffee and tea consumption in the 1992 cohort but not in the 1999 cohort. We speculate that recent changes made in Japan regarding the interior coating of cans used to package these beverages may partly explain these findings. PMID:12515686
Reyes, John Carlo B; Solon, Juan Antonio A; Rivera, Windell L
2014-07-01
A loop-mediated isothermal amplification (LAMP) assay targeting the 2-kbp repeated DNA species-specific sequence was developed for detection of Trichomonas vaginalis, the causative agent of trichomoniasis. The analytical sensitivity and specificity of the LAMP assay were evaluated using pooled genital swab and urine specimens, respectively, spiked with T. vaginalis trophozoites. Genital secretion and urine did not inhibit the detection of the parasite. The sensitivity of the LAMP was 10-1000 times higher than the PCR performed. The detection limit of LAMP was 1 trichomonad for both spiked genital swab and urine specimens. Also, LAMP did not exhibit cross-reactivity with closely-related trichomonads, Trichomonas tenax and Pentatrichomonas hominis, and other enteric and urogenital microorganisms, Entamoeba histolytica, Candida albicans, Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus. This is the first report of a LAMP assay for the detection of T. vaginalis and has prospective application for rapid diagnosis and control of trichomoniasis. Copyright © 2014 Elsevier Inc. All rights reserved.
González Paredes, Rosa María; García Pinto, Carmelo; Pérez Pavón, José Luis; Moreno Cordero, Bernardo
2016-09-01
A new method based on headspace programmed-temperature vaporizer gas chromatography with mass spectrometry has been developed and validated for the determination of amino acids (alanine, sarcosine, ethylglycine, valine, leucine, and proline) in human urine samples. Derivatization with ethyl chloroformate was employed successfully to determine the amino acids. The derivatization reaction conditions as well as the variables of the headspace sampling were optimized. The existence of a matrix effect was checked and the analytical characteristics of the method were determined. The limits of detection were 0.15-2.89 mg/L, and the limits of quantification were 0.46-8.67 mg/L. The instrumental repeatability was 1.6-11.5%. The quantification of the amino acids in six urine samples from healthy subjects was performed with the method developed with the one-point standard additions protocol, with norleucine as the internal standard. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek
2017-01-01
A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detection limits (LODs) in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples. PMID:29348966
Jaszczak, Ewa; Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek; Polkowska, Żaneta
2017-01-01
A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1-100 μ g/L for urine, 5-100 μ g/L for saliva, and 3-100 μ g/L for sweat samples with determination coefficients ( R ) > 0.992. Low detection limits (LODs) in the range of 1.8 μ g/L, 5.1 μ g/L, and 5.8 μ g/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples.
Borovcová, Lucie; Pauk, Volodymyr; Lemr, Karel
2018-05-01
New psychoactive substances represent serious social and health problem as tens of new compounds are detected in Europe annually. They often show structural proximity or even isomerism, which complicates their analysis. Two methods based on ultra high performance supercritical fluid chromatography and ultra high performance liquid chromatography with mass spectrometric detection were validated and compared. A simple dilute-filter-and-shoot protocol utilizing propan-2-ol or methanol for supercritical fluid or liquid chromatography, respectively, was proposed to detect and quantify 15 cathinones and phenethylamines in human urine. Both methods offered fast separation (<3 min) and short total analysis time. Precision was well <15% with a few exceptions in liquid chromatography. Limits of detection in urine ranged from 0.01 to 2.3 ng/mL, except for cathinone (5 ng/mL) in supercritical fluid chromatography. Nevertheless, this technique distinguished all analytes including four pairs of isomers, while liquid chromatography was unable to resolve fluoromethcathinone regioisomers. Concerning matrix effects and recoveries, supercritical fluid chromatography produced more uniform results for different compounds and at different concentration levels. This work demonstrates the performance and reliability of supercritical fluid chromatography and corroborates its applicability as an alternative tool for analysis of new psychoactive substances in biological matrixes. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Water ingestion during swimming activities in a pool: a pilot study.
Dufour, Alfred P; Evans, Otis; Behymer, Thomas D; Cantú, Ricardo
2006-12-01
Chloroisocyanurates are commonly added to outdoor swimming pools to stabilize chlorine disinfectants. The chloroisocyanurates decompose slowly to release chlorine and cyanuric acid. Studies conducted to determine if the chloroisocyanurates might be toxic to swimmers showed that they were not and that ingested cyanuric acid passed through the body unmetabolized. This fact was used to determine the amount of water swallowed during swimming activity. Fifty-three recreational swimmers, using a community swimming pool disinfected with cyanuric acid stabilized chlorine, participated in the study. The participants did not swim on the day before or after the test swim. The swimmers were asked to actively swim for at least 45 minutes and to collect their urine for the next 24 hours. Cyanuric acid was measured in pool water using high performance liquid chromatography and porous graphitic carbon columns with UV detection. The urine sample assay required a clean-up procedure to remove urinary proteins and interfering substances. Results of the study indicate that non-adults ingest about twice as much water as adults during swimming activity. The average amount of water swallowed by non-adults and adults was 37 ml and 16 ml, respectively. The design for this study and the analytical methodology used to assay cyanuric acid in swimming pool water and human urine were effective for measuring the volume of water swallowed during swimming activity.
Recommendations for standardized reporting of protein electrophoresis in Australia and New Zealand.
Tate, Jillian; Caldwell, Grahame; Daly, James; Gillis, David; Jenkins, Margaret; Jovanovich, Sue; Martin, Helen; Steele, Richard; Wienholt, Louise; Mollee, Peter
2012-05-01
Although protein electrophoresis of serum (SPEP) and urine (UPEP) specimens is a well-established laboratory technique, the reporting of results using this important method varies considerably between laboratories. The Australasian Association of Clinical Biochemists recognized a need to adopt a standardized approach to reporting SPEP and UPEP by clinical laboratories. A Working Party considered available data including published literature and clinical studies, together with expert opinion in order to establish optimal reporting practices. A position paper was produced, which was subsequently revised through a consensus process involving scientists and pathologists with expertise in the field throughout Australia and New Zealand. Recommendations for standardized reporting of protein electrophoresis have been produced. These cover analytical requirements: detection systems; serum protein and albumin quantification; fractionation into alpha-1, alpha-2, beta and gamma fractions; paraprotein quantification; urine Bence Jones protein quantification; paraprotein characterization; and laboratory performance, expertise and staffing. The recommendations also include general interpretive commenting and commenting for specimens with paraproteins and small bands together with illustrative examples of reports. Recommendations are provided for standardized reporting of protein electrophoresis in Australia and New Zealand. It is expected that such standardized reporting formats will reduce both variation between laboratories and the risk of misinterpretation of results.
Warth, Benedikt; Sulyok, Michael; Fruhmann, Philipp; Mikula, Hannes; Berthiller, Franz; Schuhmacher, Rainer; Hametner, Christian; Abia, Wilfred Angie; Adam, Gerhard; Fröhlich, Johannes; Krska, Rudolf
2012-07-15
Mycotoxins regularly occur in food worldwide and pose serious health risks to consumers. Since individuals can be exposed to a variety of these toxic secondary metabolites of fungi at the same time, there is a demand for proper analytical methods to assess human exposure by suitable biomarkers. This study reports on the development of a liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for the quantitative measurement of 15 mycotoxins and key metabolites in human urine using polarity switching. Deoxynivalenol (DON), DON-3-O-glucuronide, DON-15-O-glucuronide (D15GlcA), de-epoxy DON, nivalenol (NIV), T-2 toxin, HT-2 toxin, zearalenone, zearalenone-14-O-glucuronide, α- and β-zearalenol, fumonisins B(1) and B(2) (FB(1), FB(2)), ochratoxin A (OTA) and aflatoxin M(1) (AFM(1)) were determined without the need for any cleanup using a rapid and simple dilute and shoot approach. Validation was performed in the range of 0.005-40 µg L(-1) depending on the analyte and expected urinary concentration levels. Apparent recoveries between 78 and 119% and interday precisions of 2-17% relative standard deviation (RSD) were achieved. The applicability of the method was demonstrated by the analysis of urine samples obtained from Cameroon. In naturally contaminated urine samples up to six biomarkers of exposure (AFM(1), DON, D15GlcA, NIV, FB(1), and OTA) were detected simultaneously. We conclude that the developed LC/MS/MS method is well suited to quantify multiple mycotoxin biomarkers in human urine down to the sub-ppb range within 18 min and without any prior cleanup. The co-occurrence of several mycotoxins in the investigated samples clearly emphasizes the great potential and importance of this method to assess exposure of humans and animals to naturally occurring mycotoxins. Copyright © 2012 John Wiley & Sons, Ltd.
Almeida, C; Nogueira, J M F
2006-06-16
In this study, stir bar sorptive extraction and liquid desorption followed by high performance liquid chromatography with diode array detection (SBSE-LD-HPLC/DAD) were combined for the simultaneous determination of nine steroid sex hormones (estrone, 17alpha-estradiol, 17beta-estradiol, 17alpha-ethynylestradiol, diethylstilbestrol, mestranol, progesterone, 19-norethisterone and norgestrel) in water and urine matrices. During the method development, it has been demonstrated that equilibrium time, ionic strength and back extraction solvents are the most important parameters to control, for determining the nine-hormones in water matrices, in which stir bars coated with 126 microl of polydimethylsiloxane were used. Assays performed on 30 ml water samples spiked at 10 microg/l levels under optimised experimental conditions, yielded recoveries ranging from 11.1+/-4.9% (17beta-estradiol) to 100.2+/-10.4% (mestranol), showed that the methodology is well described by the octanol-water partition coefficients (K(PDMS/W) approximately K(O/W)) for the latter, while pronounced deviations to the theoretical efficiency (K(PDMS/W) not equal K(O/W)) were observed for the remaining hormones. From calibration studies, a good analytical performance for all hormones was attained, including a suitable precision (2.1-17.1%), low limits of detection (0.3-1.0 microg/l) and an excellent linear dynamic range (1.25-50.0 microg/l). Assays on environmental water and urine matrices showed recovery yields in worthy good agreement with the spiking level (10 microg/l), and suitability for profiling low microg/l levels of natural hormones in urine samples taken from pregnant women. The present methodology is easy, reliable and sensitive at the trace level, only requiring a low sample volume, showing to be a good analytical alternative to routine quality control for environmental and biomedical laboratories.
Zhao, Xueqing; Zeisel, Steven H; Zhang, Shucha
2015-06-17
There is a growing interest in analyzing choline, betaine, and their gut microbial metabolites including trimethylamine (TMA) and trimethylamine N-oxide (TMAO) in body fluids due to the high relevance of these compounds for human health and diseases. A stable isotope dilution (SID)-LC-MRM-MS assay was developed for the simultaneous determination of choline, betaine, TMA, TMAO, and creatinine in human plasma and urine. The assay was validated using quality control (QC) plasma samples, spiked at low, medium, and high levels. Freeze-thaw stability was also evaluated. The utility of this assay for urine was demonstrated using a nutritional clinical study on the effect of various egg doses on TMAO production in humans. This assay has a wide dynamic range (R 2 > 0.994) for all the analytes (choline: 0.122-250 μM; betaine: 0.488-1000 μM; TMA: 0.244-250 μM; TMAO: 0.061-62.5 μM; and creatinine: 0.977-2000 μM). High intra- and inter-day precision (CV < 6%) and high accuracy (< 15% error) were observed from the QC plasma samples. The assay is reliable for samples undergoing multiple freeze-thaw cycles (tested up to eight cycles). The assay also works for urine samples as demonstrated by a clinical study in which we observed a significant, positive linear response to various egg doses for urinary concentrations of all the analytes except creatinine. A rapid SID-LC-MRM-MS assay for simultaneous quantification of choline, betaine, TMA, TMAO, and creatinine has been developed and validated, and is expected to find wide application in nutrition and cardiovascular studies as well as diagnosis and management of trimethylaminuria. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Nielen, Michel W F; Lasaroms, Johan J P; Mulder, Patrick P J; Van Hende, Johan; van Rhijn, J Hans A; Groot, Maria J
2006-01-02
The abuse of esters of natural androgenic steroids in cattle fattening and sports is hard to control via routine urine testing. The esters are rapidly hydrolysed in vivo into substances which are also endogenously present in urine. In veterinary control strange findings of 17beta-testosterone and 17alpha-testosterone in urine are often ignored because of the lack of statistically sound reference data of naturally occurring levels. An interesting alternative for inconclusive urine analyses in veterinary control can be provided by the analysis of the administered steroids themselves, i.e. the analysis of intact steroid esters in hair. Unfortunately, the analysis of intact steroid esters is complicated not only by the vulnerability of the esters which precludes alkaline hydrolysis of the hair, but also by the wide polarity range of short and long-chain esters yielding very poor recoveries for either the one or the other. In this study, a multi-steroid esters LC/MS/MS screening method is presented for trace analysis of the synthetic intact esters of 17beta-testosterone and the undecylenate ester of 17beta-boldenone in bovine hair. The method, requiring only 200 mg of pulverised hair, features a mild digestion procedure using tris(2-carboxyethyl)phosphine hydrochloride (TCEP) and the use of four deuterium-labelled steroid esters as internal standards covering the wide polarity range of the analytes. In spiked hair samples for most of the analytes the limit of detection and the accuracy using isotope dilution were 2-5 ng/g and 97-105%, respectively. The applicability was demonstrated using hair samples from a controlled experiment in which six bovines were injected intramuscularly with two different doses of two commercial mixtures of testosterone esters, and with two different doses of boldenone undecylenate. Depending on the dose all administered testosterone- and boldenone esters were found to be incorporated in bovine hair following a single intramuscular injection, except testosterone propionate which dose might have been too low.
Chiesa, L; Nobile, M; Panseri, S; Sgoifo Rossi, C A; Pavlovic, R; Arioli, F
2014-12-10
The presence of β-boldenone II phase metabolites and prednisolone in urine samples, owing to endogenous or natural origin or illicit treatment, is under debate within the European Union. The detection of β-boldenone conjugates, α-boldenone conjugates at concentrations higher than 2 ng mL(-1) and prednisolone above the cut-off level of 5 ng mL(-1) in urine have been, until now, critical in deciding if illegal drug use has occurred. The use of urine sometimes is not entirely satisfactory, especially when the drug is administrated at low doses or when its metabolic conversion is very fast. This subsequently would hamper its detection in urine. The introduction of a new, advantageous matrix where the illicit treatment can be investigated would be highly appreciated. In this study, we have developed and validated a simple and unique immunoaffinity clean-up procedure, which was applied to bovine bile samples, followed by two different analytical liquid chromatography-electrospray-tandem mass spectrometry methods. The first method tests androstadienedione, α- and β-boldenone sulphate, glucuronate and related free forms, while the other method assays prednisolone, prednisone, dexamethasone, cortisone, and cortisol. The methods were validated according to European Commission Decision 2002/657/EC. The evaluated parameters were linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit and detection capability. The decision limits (CCα) were between 0.38 and 0.45 ng mL(-1) for anabolic steroids, and 0.13 and 0.15 ng mL(-1) as far as corticosteroids were concerned. Intra- and inter-day repeatability was below 15.8 and 19.9% for all analytes, respectively. The methods were applied to the analysis of some bile samples collected from untreated young bulls in order to investigate the presence of the studied steroids in this matrix. Copyright © 2014 Elsevier B.V. All rights reserved.
Pelição, Fabrício Souza; Peres, Mariana Dadalto; Pissinate, Jauber Fornaciari; De Martinis, Bruno Spinosa
2014-01-01
A gas chromatography-mass spectrometric (GC-MS) method was developed and validated for the simultaneous detection and quantification in postmortem whole blood samples of cocaine (COC), amphetamines (AMPs) and cannabis; the main drugs involved in cases of impaired driving in Brazil. The analytes were extracted by solid-phase extraction by means of Bond-Elute Certify cartridges, derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide at 80°C for 30 min and analyzed by GC-MS. Linearity ranged from 10 to 500 ng/mL, except for ecgonine methyl ester, for which linearity ranged from 10 to 100 ng/mL. Inter- and intra-day imprecision ranged from 2.8 to 18.4% and from 1.5 to 14.9%, respectively. Accuracy values lay between 86.9 and 104.4%. The limit of quantitation for all drugs was 10 ng/mL and recoveries were >74% for all analytes, except for cannabinoids, which showed poor recovery (∼30%). The developed method was applied to real samples collected from deceased victims due to traffic accidents. These samples were selected according to the results obtained in immunoassay screening on collected urine samples. Five samples were positive for the presence of COC and metabolites, four samples were positive for cannabinoids, six samples were positive for AMPs and two samples were drug negative. Some samples were positive for more than one class of drug. Results obtained from whole blood samples showed good agreement with urine screening. The developed method proved capable of quantifying all three classes of drugs of abuse proposed in this study, through a one-step extraction procedure. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
[Biological monitoring of occupational exposure to sevoflurane].
Imbriani, M; Zadra, P; Negri, S; Alessio, A; Maestri, L; Ghittori, S
2001-01-01
Sevoflurane has been used in the last few years in brief surgical operations, either alone or in combination with nitrous oxide. Occupationally exposed groups include anesthesiologists, surgeons and operating room nurses. In 1977 the National Institute for Occupational Safety and Health (NIOSH) recommended that occupational exposure to halogenated anesthetic agents (halothane, enflurane, and isoflurane), when used as the sole anesthetic, should be controlled so that no worker would be exposed to time-weighted average concentrations greater than 2 ppm during anesthetic administration. When halogenated anesthetics are associated with nitrous oxide, NIOSH recommends that the limit value should not exceed 0.5 ppm. We think these recommendations can be extended to sevoflurane. Metabolism of sevoflurane is catalyzed by cytochrome P-450; this involves oxidation of the fluoromethyl side chain of the molecule, followed by glucuronidation. Two urinary metabolites of sevoflurane have been identified: inorganic fluoride (which, however, is not specific) and a non-volatile compound that yields hexafluoroisopropanol (HFIP) when digested with the enzyme beta-glucuronidase. In order to investigate the role of urinary HFIP as an indicator of occupational exposure to sevoflurane (CI, ppm), CI was measured in 145 members of 18 operating room staffs. The measurements of the time-weighted average of CI in the breathing zone were made by means of diffusive personal samplers. Each sampler was exposed during the whole working period. Sevoflurane was desorbed with CS2 from charcoal and the concentrations were measured on a gas chromatograph (GC) equipped with a mass selective detector (MSD). The GC was equipped with a 25 meter cross-linked phenylmethylsilicon column (internal diameter 0.2 mm). GC conditions were as follows: injector column temperature = 200 degrees C; column temperature = 30 degrees C; carrier gas = helium; injection technique of samples = splitless. The analytical conditions for the MSD were the following: ion mass monitored = 131 m/e; dwell time = 50 msec; selected ion monitoring window time = 0.1 amu; electromultiplier = 400 V. Urine samples were collected near the end of the shift and were analyzed for HFIP by head-space gas chromatography after glucuronide hydrolysis. 0.5 ml of urine and 1.5 ml of 10 M sulfuric acid were added to 21.8 ml headspace vials. The vials were immediately capped, vortexed, and loaded into the headspace autosampler. Samples were maintained at 100 degrees C for 30 min, after which glucuronide hydrolysis was 99% complete. Analyses were performed on a GC equipped with a MSD. The analytical conditions for urine analysis were as follows: cross-linked 5% phenylmethylsilicon column (internal diameter 0.2 mm, length 25 m); column temperature = 35 degrees C; carrier gas = helium. The analytical conditions for the MSD were: monitored ions = 51.05 and 99; dwell time = 100 ms; selected ion monitoring window time = 0.1 amu; electromultiplier voltage = 2000 Volt. With our analytical procedure, the detection limit of HFIP in urine was 20 micrograms/L. The variation coefficient (CV) for HFIP measurement in urine was 8.7% (on 10 determinations; mean value = 1000 micrograms/L). The median value of CI was 0.77 ppm (Geometric Standard Deviation = 4.08; range = 0.05-27.9 ppm). The correlation between CI and HFIP (Cu, microgram/L) was: Log Cu (microgram/L) = 0.813 x Log CI (ppm) + 2.517 (r = 0.79, n = 145, p < 0.0001). On the basis of the equation it was possible to establish tentatively the biological limit values corresponding to the respective occupational exposure limit values proposed for sevoflurane. According to our experimental results, HFIP values of 488 micrograms/L and 160 micrograms/L correspond to airborne sevoflurane concentrations of 2 and 0.5 ppm respectively.
NASA Technical Reports Server (NTRS)
Johnson, R. D.
1977-01-01
Organic cosmochemistry, organic materials in space exploration, and biochemistry of man in space are briefly surveyed. A model of Jupiter's atmosphere is considered, and the search for organic molecules in the solar system and in interstellar space is discussed. Materials and analytical techniques relevant to space exploration are indicated, and the blood and urine analyses performed on Skylab are described.
Liu, Min; Zhang, Chunsun; Liu, Feifei
2015-09-03
In this work, we first introduce the fabrication of microfluidic cloth-based analytical devices (μCADs) using a wax screen-printing approach that is suitable for simple, inexpensive, rapid, low-energy-consumption and high-throughput preparation of cloth-based analytical devices. We have carried out a detailed study on the wax screen-printing of μCADs and have obtained some interesting results. Firstly, an analytical model is established for the spreading of molten wax in cloth. Secondly, a new wax screen-printing process has been proposed for fabricating μCADs, where the melting of wax into the cloth is much faster (∼5 s) and the heating temperature is much lower (75 °C). Thirdly, the experimental results show that the patterning effects of the proposed wax screen-printing method depend to a certain extent on types of screens, wax melting temperatures and melting time. Under optimized conditions, the minimum printing width of hydrophobic wax barrier and hydrophilic channel is 100 μm and 1.9 mm, respectively. Importantly, the developed analytical model is also well validated by these experiments. Fourthly, the μCADs fabricated by the presented wax screen-printing method are used to perform a proof-of-concept assay of glucose or protein in artificial urine with rapid high-throughput detection taking place on a 48-chamber cloth-based device and being performed by a visual readout. Overall, the developed cloth-based wax screen-printing and arrayed μCADs should provide a new research direction in the development of advanced sensor arrays for detection of a series of analytes relevant to many diverse applications. Copyright © 2015 Elsevier B.V. All rights reserved.
Wang, Yuan; Shi, Yali; Vestergren, Robin; Zhou, Zhen; Liang, Yong; Cai, Yaqi
2018-09-15
Non-invasive samples present ethical and practical benefits for investigating human exposure to hazardous contaminants, but analytical challenges and difficulties to interpret the results limit their application in biomonitoring. Here we investigated the potential for using hair, nail and urine samples as a measure of internal exposure to an array of legacy and emerging per- and polyfluoroalkyl substances (PFASs) in two populations with different exposure conditions. Paired urine-serum measurements of PFASs from a group of highly exposed fishery employees displayed strong correlations for PFASs with three to eight perfluorinated carbons (ρ > 0.653; p < 0.01). Consistent statistical correlations and transfer ratios in nails and hair from both populations demonstrated that these non-invasive samples can be used as a measure of internal exposure to perfluorooctane sulfonic acid and C8 chlorinated polyfluoralkyl ether sulfonic acid (C8 Cl-PFESA). Contrastingly, the infrequent detections and/or lack of consistent transfer ratios for perfluorooctanoic acid, perfluorononanoic acid and short-chain PFASs in hair and nail samples indicate passive uptake from the external environment rather than uptake and internal distribution. Collectively, the study supports the use of urine samples as a valid measure of internal exposure for a range of short- and medium-chain PFASs, while the validity of nail and hair samples as a measure of internal exposure may vary for different PFASs and populations. The ubiquitous detection of C8 Cl-PFESA in all sample matrices from both populations indicates widespread exposure to this contaminant of emerging concern in China. Copyright © 2018 Elsevier B.V. All rights reserved.
Auer, B L; Auer, D; Rodgers, A L
1998-03-01
The present study was undertaken to determine the effect of ingestion of large doses of vitamin C on urinary oxalate excretion and on a number of other biochemical and physicochemical risk factors associated with calcium oxalate urolithiasis. A further objective was to determine urinary ascorbate excretion and to relate it qualitatively to ingested levels of the vitamin and oxalate excretion. Ten healthy males participated in a protocol in which 4 g ascorbic acid was ingested for 5 days. Urines (24 h) were collected prior to, during and after the protocol. The urine collection procedure was designed to allow for the analysis of oxalate in the presence and absence of an EDTA preservative and for the analysis of ascorbic acid by manual titration using 2,6 dichlorophenolindophenol. Physicochemical risk factors such as the calcium oxalate relative supersaturation and Tiselius risk index were calculated from urine composition. The results showed that erroneously high analytical oxalate levels occur in the asence of preservative. In the preserved samples there was no significant increase in oxalate excretion at any stage of the protocol. Ascorbate excretion increased when vitamin C ingestion commenced but levelled out after 24 hours suggesting that saturation of the metabolic pool is reached within 24 hours after which ingested ascorbic acid is excreted unmetabolized in the urine. While transient statistically significant changes occurred in some of the biochemical risk factors, they were not regarded as being clinically significant. There were no changes in either the calcium oxalate relative supersaturation or Tiselius risk index. It is concluded that ingestion of large doses of ascorbic acid does not affect the principal risk factors associated with calcium oxalate kidney stone formation.
Rani, Susheela; Malik, Ashok K; Singh, Baldev
2012-02-01
A method for the simultaneous determination of the antiepileptic drugs, phenobarbital (PHB), phenytoin (PTN), carbamazepine (CBZ), primidone (PRM) and oxcarbazepine (OXC) in human plasma and urine samples by using micro-extraction in a packed syringe as the sample preparation method connected with LC/UV (MEPS/LC/UV) is described. Micro-extraction in a packed syringe (MEPS) is a new miniaturized, solid-phase extraction technique that can be connected online to gas or liquid chromatography without any modifications. In MEPS approximately 1 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising, easy to use, fully automated, inexpensive and quick. The standard curves were obtained within the concentration range 1-500 ng/mL in both plasma and urine samples. The results showed high correlation coefficients (R(2) >0.988) for all of the analytes within the calibration range. The extraction recovery was found to be between 88.56 and 99.38%. The limit of quantification was found to be between 0.132 and 1.956 ng/mL. The precision (RSD) values of quality control samples (QC) had a maximum deviation of 4.9%. A comparison of the detection limits with similar methods indicates high sensitivity of the present method. The method is applied for the analysis of these drugs in real urine and plasma samples of epileptic patients. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
In Vitro and In Vivo Human Metabolism of Synthetic Cannabinoids FDU-PB-22 and FUB-PB-22.
Diao, Xingxing; Scheidweiler, Karl B; Wohlfarth, Ariane; Pang, Shaokun; Kronstrand, Robert; Huestis, Marilyn A
2016-03-01
In 2014, FDU-PB-22 and FUB-PB-22, two novel synthetic cannabinoids, were detected in herbal blends in Japan, Russia, and Germany and were quickly added to their scheduled drugs list. Unfortunately, no human metabolism data are currently available, making it challenging to confirm their intake. The present study aims to identify appropriate analytical markers by investigating FDU-PB-22 and FUB-PB-22 metabolism in human hepatocytes and confirm the results in authentic urine specimens. For metabolic stability, 1 μM FDU-PB-22 and FUB-PB-22 was incubated with human liver microsomes for up to 1 h; for metabolite profiling, 10 μM was incubated with human hepatocytes for 3 h. Two authentic urine specimens from FDU-PB-22 and FUB-PB-22 positive cases were analyzed after β-glucuronidase hydrolysis. Metabolite identification in hepatocyte samples and urine specimens was accomplished by high-resolution mass spectrometry using information-dependent acquisition. Both FDU-PB-22 and FUB-PB-22 were rapidly metabolized in HLM with half-lives of 12.4 and 11.5 min, respectively. In human hepatocyte samples, we identified seven metabolites for both compounds, generated by ester hydrolysis and further hydroxylation and/or glucuronidation. After ester hydrolysis, FDU-PB-22 and FUB-PB-22 yielded the same metabolite M7, fluorobenzylindole-3-carboxylic acid (FBI-COOH). M7 and M6 (hydroxylated FBI-COOH) were the major metabolites. In authentic urine specimens after β-glucuronidase hydrolysis, M6 and M7 also were the predominant metabolites. Based on our study, we recommend M6 (hydroxylated FBI-COOH) and M7 (FBI-COOH) as suitable urinary markers for documenting FDU-PB-22 and/or FUB-PB-22 intake.
Robandt, Paul P; Reda, Louis J; Klette, Kevin L
2008-10-01
A fully automated system utilizing a liquid handler and an online solid-phase extraction (SPE) device coupled with liquid chromatography-tandem mass spectrometry (LC-MS-MS) was designed to process, detect, and quantify benzoylecgonine (BZE), meta-hydroxybenzoylecgonine (m-OH BZE), para-hydroxybenzoylecgonine (p-OH BZE), and norbenzoylecgonine (nor-BZE) metabolites in human urine. The method was linear for BZE, m-OH BZE, and p-OH BZE from 1.2 to 10,000 ng/mL with limits of detection (LOD) and quantification (LOQ) of 1.2 ng/mL. Nor-BZE was linear from 5 to 10,000 ng/mL with an LOD and LOQ of 1.2 and 5 ng/mL, respectively. The intrarun precision measured as the coefficient of variation of 10 replicates of a 100 ng/mL control was less than 2.6%, and the interrun precision for 5 replicates of the same control across 8 batches was less than 4.8% for all analytes. No assay interference was noted from controls containing cocaine, cocaethylene, and ecgonine methyl ester. Excellent data concordance (R2 > 0.994) was found for direct comparison of the automated SPE-LC-MS-MS procedure and an existing gas chromatography-MS procedure using 94 human urine samples previously determined to be positive for BZE. The automated specimen handling and SPE procedure, when compared to the traditional extraction schema, eliminates the human factors of specimen handling, processing, extraction, and derivatization, thereby reducing labor costs and rework resulting from batch handling issues, and may reduce the number of fume hoods required in the laboratory.
Carignan, Courtney C; Butt, Craig M; Stapleton, Heather M; Meeker, John D; Minguez-Alarcón, Lidia; Williams, Paige L; Hauser, Russ
2017-08-01
Use of organophosphate flame retardants (PFRs) has increased over the past decade with the phase out of polybrominated diphenyl ethers. Urinary metabolites of PFRs are used as biomarkers of exposure in epidemiologic research, which typically uses samples collected and stored in polypropylene plastic cryovials. However, a small study suggested that the storage vial material may influence reported concentrations. Therefore, we aimed to examine the influence of the storage vial material on analytical measurement of PFR urinary metabolites. Using urine samples collected from participants in the Environment and Reproductive Health (EARTH) Study, we analyzed the PFR metabolites in duplicate aliquots that were stored in glass and plastic vials (n = 31 pairs). Bis(1,3-dichloro-2-propyl) phosphate (BDCIPP), diphenyl phosphate (DPHP) and isopropyl-phenyl phenyl phosphate (ip-PPP) were detected in 98%, 97% and 87% of duplicates. We observed high correlations between glass-plastic duplicates for BDCIPP (r s = 0.95), DPHP (r s = 0.79) and ip-PPP (r s = 0.82) (p < 0.0001). Urinary ip-PPP was an average of 0.04 ng/ml (p = 0.04) higher among samples stored in glass, with a mean relative difference of 14%. While this difference is statistically significant, it is small in magnitude. No differences were observed for BDCIPP or DPHP, however future research should seek to reduce the potential for type II error (false negatives). We conclude that storing urine samples in polypropylene plastic cryovials may result in slightly reduced concentrations of urinary ip-PPP relative to storage in glass vials and future research should seek to increase the sample size, reduce background variability and consider the material of the urine collection cup. Copyright © 2017 Elsevier Ltd. All rights reserved.
Storage Time and Urine Biomarker Levels in the ASSESS-AKI Study
Liu, Kathleen D.; Siew, Edward D.; Reeves, W. Brian; Himmelfarb, Jonathan; Go, Alan S.; Hsu, Chi-yuan; Bennett, Michael R.; Devarajan, Prasad; Ikizler, T. Alp; Kaufman, James S.; Kimmel, Paul L.; Chinchilli, Vernon M.; Parikh, Chirag R.
2016-01-01
Background Although stored urine samples are often used in biomarker studies focused on acute and chronic kidney disease, how storage time impacts biomarker levels is not well understood. Methods 866 subjects enrolled in the NIDDK-sponsored ASsessment, Serial Evaluation, and Subsequent Sequelae in Acute Kidney Injury (ASSESS-AKI) Study were included. Samples were processed under standard conditions and stored at -70°C until analyzed. Kidney injury molecule-1 (KIM-1), neutrophil gelatinase-associated lipocalin (NGAL), interleukin-18 (IL-18), and liver fatty acid binding protein (L-FABP) were measured in urine samples collected during the index hospitalization or an outpatient visit 3 months later. Mixed effects models were used to determine the effect of storage time on biomarker levels and stratified by visit. Results Median storage was 17.8 months (25–75% IQR 10.6–23.7) for samples from the index hospitalization and 14.6 months (IQR 7.3–20.4) for outpatient samples. In the mixed effects models, the only significant association between storage time and biomarker concentration was for KIM-1 in outpatient samples, where each month of storage was associated with a 1.7% decrease (95% CI -3% to -0.3%). There was no relationship between storage time and KIM-1 levels in samples from the index hospitalization. Conclusion There was no significant impact of storage time over a median of 18 months on urine KIM-1, NGAL, IL-18 or L-FABP in hospitalized samples; a statistically significant effect towards a decrease over time was noted for KIM-1 in outpatient samples. Additional studies are needed to determine whether longer periods of storage at -70°C systematically impact levels of these analytes. PMID:27788160
Luo, Xialin; Li, Gongke; Hu, Yufei
2017-04-01
In this work, a novel NH 2 -MIL-53(Al) incorporated poly(styrene-divinylbenzene-methacrylic acid) (poly(St-DVB-MAA)) monolith was prepared via chemical fabrication. Moreover, it has been efficiently applied to the in-tube solid-phase microextraction (SPME) for online coupling with high-performance liquid chromatography (HPLC) to the direct determination of five estrogens in human urine samples. The NH 2 -MIL-53(Al)-polymer monolith was suitable for in-tube SPME owing to its good permeability, high extraction efficiency, chemical stability, good reproducibility and long lifetime. The extraction conditions including extraction solvent, pH of sample solution, flow rate of extraction and desorption, and desorption volume were investigated. Under the optimum conditions, the enrichment factors were 180-304 and saturated amounts of extraction were 2326-21393 pmol for estriol, 17β-estradiol, estrone, ethinyl estradiol and progesterone, respectively. The adsorption mechanism was also explored which contributed to its strong extraction to target compounds. The proposed method had low limit of detection (2.0-40ng/L) and good linearity (with R 2 between 0.9908 and 0.9978). Four endogenous estrogens were detected in urine samples and the recoveries of all five analytes were ranged from 75.1-120% with relative standard deviations (RSDs) less than 8.7%. The results showed that the proposed online SPME-HPLC method based on NH 2 -MIL-53(Al)-polymer monolithic column was highly sensitive for directly monitoring trace amount of estrogens in human urine sample. Copyright © 2016 Elsevier B.V. All rights reserved.
Chen, Xuan; Bai, Xiaohong; Wang, Xiao; Wang, Jing; Bu, Wei
2010-12-01
The preferred conformations of the ephedrine and pseudoephedrine in Ephedra sinica Stapf and rat urine were analyzed by the hollow fiber liquid-phase microextraction (HF-LPME) and their extraction mechanisms were illuminated. The method of the separation of the ephedrine and pseudoephedrine and the determination of their concentrations with high performance liquid chromatography (HPLC) were established. The optimal experimental conditions were as follows: the organic phase carrier was the hollow fiber of polyvinylidene fluoride (MOF-503), organic solvent was n-hexanol, the extraction time was 35 min, the stirring rate was 1200 r/min, the sample phase was the NaOH solution (5 mol/L) of the analyte, the acceptor was 0.01 mol/L H2SO4 solution. The extracts were analyzed by HPLC. Under the optimal conditions, the method is convenient and highly sensitive. In Ephedra sinica Stapf, the linear ranges of ephedrine and pseudoephedrine were 5-100 microg/L, the detection limits were 1.9 microg/L and 1.2 microg/L and the enrichment factors were 38 and 61, respectively. The average recoveries of ephedrine and pseudoephedrine were 100.6% +/- 1.2% and 103.2% +/- 3.5%, respectively. In rat urine, their linear ranges were 100 - 5 x 10(4) microg/L, the detection limits were 30 microg/L and 42 microg/L and the enrichment factors were 20 and 17, respectively. In rat urine, their average recoveries were 108.4% +/- 4.4% and 106. 1% +/- 5.4%, respectively. The obtained results indicated that the method can be successfully applied for the extraction and determination of the ephedrine and pseudoephedrine in Ephedra sinica Stapf and rat urine.
Aprea, C; Sciarra, G; Bozzi, N
1997-01-01
Two methods for the quantitative analysis of 2,4-dichlorophenoxyacetic acid (2,4-D) and 2-methyl-4-chlorophenoxyacetic acid (MCPA) in urine were compared. The first was an high-performance liquid chromatography method using a C8 column with ion suppression and diode array detection. The urine extracts were first purified by solid-phase extraction (SPE) on silica capillary columns. The detection limit of the method was 15 micrograms/L for both compounds. The percentage coefficient of variation of the whole analysis evaluated at a concentration of 125.0 micrograms/L was 6.2% for 2,4-D and 6.8% for MCPA. The mean recovery of analysis was 81% for 2,4-D and 85% for MCPA. The second was a gas chromatographic (GC) method in which the compounds were first derivatized with pentafluorobenzylbromide to pentafluorobenzyl esters, which were determined with a slightly polar capillary column and electron capture detection. Before GC analysis, the urine extracts were purified by SPE on silica capillary columns. This method had a detection limit of 1 microgram/L for both compounds and a percentage coefficient of variation of the whole analysis, evaluated at a concentration of 30.0 micrograms/L, of 8% for 2,4-D, and of 5.5% for MCPA. the mean recovery was 87% for 2,4-D and 94% for MCPA. The low detection limit made the second method suitable for assaying the two herbicides in the general population. Duplicate analysis of ten urine samples from occupationally exposed subjects by the two methods gave identical results for a wide range of concentrations.
Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.
Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan
2017-12-01
Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.
Monitoring 2-phenylethanamine and 2-(3-hydroxyphenyl)acetamide sulfate in doping controls.
Sigmund, Gerd; Dib, Josef; Tretzel, Laura; Piper, Thomas; Bosse, Christina; Schänzer, Wilhelm; Thevis, Mario
2015-01-01
2-Phenylethanamine (phenethylamine, PEA) represents the core structure of numerous drugs with stimulant-like properties and is explicitly featured as so-called specified substance on the World Anti-Doping Agency (WADA) Prohibited List. Due to its natural occurrence in humans as well as its presence in dietary products, studies concerning the ability of test methods to differentiate between an illicit intake and the renal elimination of endogenously produced PEA were indicated. Following the addition of PEA to the Prohibited List in January 2015, retrospective evaluation of routine doping control data of 10 190 urine samples generated by combined gas chromatography-mass spectrometry and nitrogen phosphorus-specific detection (GC-MS/NPD) was performed. Signals for PEA at approximate concentrations > 500 ng/mL were observed in 31 cases (0.3%), which were subjected to a validated isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) test method for accurate quantification of the target analyte. Further, using elimination study urine samples collected after a single oral administration of 250 mg of PEA hydrochloride to two healthy male volunteers, two tentatively identified metabolites of PEA were observed and evaluated concerning their utility as discriminative markers for PEA intake. The ID-LC-MS/MS approach was extended to allow for the simultaneous detection of PEA and 2-(3-hydroxyphenyl)acetamide sulfate (M1), and concentration ratios of M1 and PEA were calculated for elimination study urine samples and a total of 205 doping control urine samples that returned findings for PEA at estimated concentrations of 50-2500 ng/mL. Urine samples of the elimination study with PEA yielded concentration ratios of M1/PEA up to values of 9.4. Notably, the urinary concentration of PEA did increase with the intake of PEA only to a modest extent, suggesting a comprehensive metabolism of the orally administered substance. Conversely, doping control urine samples with elevated (>50 ng/mL) amounts of PEA returned quantifiable concentrations of M1 only in 3 cases, which yielded maximum ratios of M1/PEA of 0.9, indicating an origin of PEA other than an orally ingested drug formulation. Consequently, the consideration of analyte abundance ratios (e.g. M1/PEA) is suggested as a means to identify the use of PEA by athletes, but further studies to support potential decisive criteria are warranted. Copyright © 2015 John Wiley & Sons, Ltd.
Optimization for Peptide Sample Preparation for Urine Peptidomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sigdel, Tara K.; Nicora, Carrie D.; Hsieh, Szu-Chuan
2014-02-25
Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides andmore » the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.« less
2011-01-01
A new spectrophotometric method is developed for the determination of phenylpropanolamine HCl (PPA), ephedrine HCl (EPH) and pseudoephedrine HCl (PSE) in pharmaceutical preparations and spiked human urine. The method involved heat-catalyzed derivatization of the three drugs with 2,4-dinitrofluorobenzene (DNFB) producing a yellow colored product peaking at 370 nm for PPA and 380 nm for EPH and PSE, respectively. The absorbance concentration plots were rectilinear over the range of 2-20 for PPA and 1-14 μg/mL for both of EPH and PSE, respectively. The limit of detection (LOD) values were 0.20, 0.13 and 0.20 μg/mL for PPA, EPH and PSE, respectively and limit of quantitation (LOQ) values of 0.60 and 0.40 and 0.59 μg/mL for PPA, EPH and PSE, respectively. The analytical performance of the method was fully validated and the results were satisfactory. The proposed method was successfully applied to the determination of the three studied drugs in their commercial dosage forms including tablets, capsules and ampoules with good percentage recoveries. The proposed method was further applied for the determination of PSE in spiked human urine with a mean percentage recovery of 108.17 ± 1.60 for (n = 3). Statistical comparison of the results obtained with those of the comparison methods showed good agreement and proved that there was no significant difference in the accuracy and precision between the two methods. The mechanism of the reaction pathway was postulated. PMID:22032335
Dong, Ying; Yan, Kuan; Ma, Yanhua; Wang, Shan; He, Genye; Deng, Jing; Yang, Zhiyong
2015-10-01
A novel, reliable and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed with dynamic multiple reaction monitoring (dMRM) mode for the simultaneous screening of 71 stimulants and 7 metabolites in human urine using unsophisticated MS instruments (Agilent triple-quadruple 6410 B mass spectrometer). With a known retention time of an analyte, dMRM algorithm monitors each MRM transition only around its expected retention time. Therefore, dMRM enables the maximization of dwell times and provides much higher sensitivity and reproducibility than the conventional multiple reaction monitoring mode (cMRM). After precipitation of protein, the urine sample was injected into LC-MS-MS system directly without sample pre-concentration. For comparison, cMRM and dMRM acquisitions were performed under the same chromatographic conditions. The result showed that the signal response and quality of the chromatograms for each stimulant improved significantly with dMRM over cMRM. The method has been fully validated giving limits of detection (0.1-25 ng/mL) satisfactory for its application to anti-doping analysis. The repeatability of the concentrations and the retention times are good both for intra- and for inter-day experiments (%CV of concentrations always <20 and %CV of retention times <0.5). The method also afforded satisfactory results in terms of accuracy, matrix effect and specificity. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Evaluation of a new automated microscopy urine sediment analyser - sediMAX conTRUST®.
Bogaert, Laura; Peeters, Bart; Billen, Jaak
2017-04-01
This study evaluated the performance of the stand-alone sediMAX conTRUST (77Elektronika, Budapest, Hungary) analyser as an alternative to microscopic analysis of urine. The validation included a precision, carry-over, categorical correlation and diagnostic performance study with manual phase-contrast microscopy as reference method. A total of 260 routine urine samples were assessed. The within-run precision was much better at higher concentrations than at very low concentrations. The precision met our predefined limits for all the elements at the different concentrations, with the exception of the lowest RBC, the WBC, pathological casts and crystals count. There was no sample carry-over. The analyser showed good categorical agreement with manual microscopy for RBC and WBC counts, moderate agreement for yeast cells, crystals and squamous epithelial cells and bad agreement for non-squamous epithelial cells, bacteria and casts. Diagnostic performance was satisfying only for RBC, WBC and yeast cells. The number of false negative results was acceptable (≤4%) for all elements after connecting the sediMAX conTRUST with an automatic strip reader (AutionMAX) and after implementation of review rules. We conclude that the sediMAX conTRUST should be used as a screening tool in combination with an automatic strip reader, for the identification of normal samples. Therefore, adequate review rules should be defined. Manual microscopy is still required in 'flagged' pathological samples. Despite the poor analytical performance on pathological samples, the images on the screen can be used for interpretation without the microscope and can be stored as PDF-documents for archiving the results.
Shermatov, Kabil; Zeyrek, Dost; Yildirim, Faruk; Kilic, Mehmet; Cebi, Nazime; Kocyigit, Abdurrahim
2012-12-01
To compare oxidative status, total antioxidant capacity and values of DNA damage in peripheral blood lymphocytes in children exposed to secondhand cigarette smoke with healthy controls. Analytical, Observational. 54 children without any chronic diseases, attending the healthy child monitoring polyclinic. These comprised 27 children who had been exposed to passive cigarette smoke and 27 children who had not been exposed to cigarette smoke. Urine cotinine levels by the chemiluminescent technique; DNA damage by alkaline comet assay; and total oxidant status (TOS) using a novel automated measurement method. The mean urine cotinine, TOS, Oxidative Stress Index (OSI) and DNA damage values of the group exposed to cigarette smoke were determined to be at significantly higher level compared to the group not exposed to cigarette smoke (P<0.001). No statistically significant difference was determined in the TAS level between the two groups (P=0.1) The results showed that TOS levels, OSI index and DNA damage in peripheral blood lymphocytes were significantly higher in children exposed to secondhand cigarette smoke than in those not exposed to secondhand cigarette smoke.
Carling, R S; Hogg, S L; Wood, T C; Calvin, J
2008-11-01
Creatine plays an important role in the storage and transmission of phosphate-bound energy. The cerebral creatine deficiency syndromes (CCDS) comprise three inherited defects in creatine biosynthesis and transport. They are characterized by mental retardation, speech and language delay and epilepsy. All three disorders cause low-creatine signal on brain magnetic resonance spectroscopy (MRS); however, MRS may not be readily available and even when it is, biochemical tests are required to determine the underlying disorder. Analysis was performed by liquid chromatography-tandem mass spectrometry in positive ionization mode. Samples were analysed underivatized using a rapid 'dilute and shoot' approach. Chromatographic separation of the three compounds was achieved. Stable isotope internal standards were used for quantification. Creatine, creatinine and guanidinoacetate were measured with a 2.5 minute run time. For guanidinoacetate, the standard curve was linear to at least 5000 mumol/L and for creatine and creatinine it was linear to at least 25 mmol/L. The lower limit of quantitation was 0.4 mumol/L for creatine and guanidinoacetate and 0.8 mumol/L for creatinine. Recoveries ranged from 86% to 106% for the three analytes. Intra- and inter-assay variation for each analyte was <10% in both urine and plasma. A tandem mass spectrometric method has been developed and validated for the underivatized determination of guanidinoacetate, creatine and creatinine in human urine and plasma. Minimal sample preparation coupled with a rapid run time make the method applicable to the routine screening of patients with suspected CCDS.
Abu-Qare, A W; Abou-Donia, M B
2001-04-25
This study describes a chromatographic method for the determination of diazepam, an anxiolytic drug that is also used as an antidote against nerve agent seizures, its metabolites N-desmethyldiazepam, and temazepam, the anti-nerve agent drug pyridostigmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) and its metabolite N-methyl-3-hydroxypyridinium bromide in rat plasma and urine. The compounds were extracted using C18 Sep-Pak Vac 3cc (500 mg) cartridges and separated using isocratic mobile phase of methanol, acetonitrile and water (pH 3.2) (10:40:50) at a flow-rate of 0.5 ml/min in a period of 12 min, and UV detection ranging between 240 and 280 nm. The limits of detection for all analytes ranged between 20 and 50 ng/ml, while limits of quantitation were 100 ng/ml. Average percentage extraction recoveries of five spiked plasma samples were 79.1+/-7.7, 83.5+/-6.4, 83.9+/-5.9, 71.3+/-6.0 and 77.7+/-5.6, and from urine 79.4+/-7.9, 83.1+/-6.9, 73.6+/-7.7, 74.3+/-7.1 and 77.6+/-5.9 for diazepam, N-desmethyldiazepam, temazepam, pyridostigmine bromide, and N-methyl-3-hydroxypyridinium bromide, respectively. The relationship between peak areas and concentration was linear over the range between 100 and 1000 ng/ml. This method was applied to determine the above analytes following a single oral administration in rats as a tool to study the pharmacokinetic profile of each compound, alone and in combination.
Abu-Qare, A W; Abou-Donia, M B
2001-09-01
A simple and reliable method was developed for the quantification of depleted uranium, the anti nerve agent drug pyridostigmine bromide (PB;3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) and its metabolite N-methyl-3-hydroxypyridinium bromide in rat plasma and urine. The method involved using solid phase extraction and spectrophotometric determination of uranium, and high performance liquid chromatography (HPLC) with reversed phase C(18) column, and UV detection at 280 nm for PB and its metabolite. Uranium was derivatized using dibenzoylmethane (DBM) then the absorbance was measured at 405 nm. PB and its metabolite were separated using a gradient of 1--40% acetonitrile in 0.1% triflouroacetic acid water solution (pH 3.2) at a flow rate of 0.8 ml/min in a period of 14 min. Limits of detection were 2 ng/ml for uranium and 50 ng/ml for PB and its metabolite. Limits of quantitation were between 10 and 100 ng/ml for uranium and the other two analytes, respectively. Average percentage recovery of five spiked plasma samples were 83.7+/-8.6, 76.8+/-6.7, 79.1+/-7.1, and from urine 82.7+/-8.6, 79.3+/-9.5 and 78.0+/-6.2, for depleted uranium, PB and N-methyl-3-hydroxypyridinium bromide, respectively. The relationship between peak areas and concentration was linear for standards between 100 and 1000 ng/ml for all three analytes. This method was applied to analyze the above chemicals and metabolites following combined administration in rats.
Simultaneous analyses of cocaine, cocaethylene, and their possible metabolic and pyrolytic products.
Cardona, Patrick S; Chaturvedi, Arvind K; Soper, John W; Canfield, Dennis V
2006-02-10
A method was developed for simultaneously analyzing cocaine (COC), benzoylecgonine (BZE), norbenzoylecgonine (BNE), norcocaine (NCOC), ecgonine (ECG), ecgonine methyl ester (EME), m-hydroxybenzoylecgonine (HBZE), anhydroecgonine methyl ester (AEME), cocaethylene (CE), norcocaethylene (NCE), and ecgonine ethyl ester (EEE) in blood, urine, and muscle. Available deuterated analogs of these analytes were used as internal standards. Proteins from blood and muscle homogenate were precipitated with cold acetonitrile. After the removal of acetonitrile by evaporation, the supernatants and urine were subjected to solid-phase extraction. The eluted analytes were converted to their hydrochloride salts and derivatized with pentafluoropropionic anhydride and 2,2,3,3,3-pentafluoro-1-propanol. The derivatized products were analyzed by a gas chromatograph (GC)/mass spectrometer by selected ion monitoring. The limit of detection (LOD) for COC, BZE, NCOC, EME, CE, NCE, and EEE was 2ng/ml, while the LODs for BNE, ECG, HBZE, and AEME were 25, 640, 50, and 13 ng/ml, respectively. This method was successfully applied in analyzing 13 case samples from aviation accident pilot fatalities and motor vehicle operators. AEME concentrations found in the 13 samples were consistent with those produced solely by the GC inlet pyrolysis of COC controls in blood. Anhydroecgonine cannot be used as a marker for the abuse of COC by smoking because it is also pyrolytically produced from COC metabolites on the GC inlet. The developed method can be effectively adopted for analyzing COC and related compounds in urine, blood, and muscle by a single extraction with increased sensitivity through formation of hydrochloride salts and using a one-step derivatization.
Quantification of urinary AICAR concentrations as a matter of doping controls.
Thomas, Andreas; Beuck, Simon; Eickhoff, Jens Christian; Guddat, Sven; Krug, Oliver; Kamber, Matthias; Schänzer, Wilhelm; Thevis, Mario
2010-04-01
Influencing the endurance in elite sports is one of the key points in modern sports science. Recently, a new class of prohibited substances reached in the focus of doping control laboratories and their misuse was classified as gene doping. The adenosine monophosphate activated protein kinase activator 5-amino-4-imidazolecarboxyamide ribonucleoside (AICAR) was found to significantly enhance the endurance even in sedentary mice after treatment. Due to endogenous production of AICAR in healthy humans, considerable amounts were present in the circulation and, thus, were excreted into urine. Considering these facts, the present study was initiated to fix reference values of renally cleared AICAR in elite athletes. Therefore a quantitative analytical method by means of isotope-dilution liquid chromatography (analytical column: C6-phenyl) coupled to tandem mass spectrometry, after a sample preparation consisting of a gentle dilution of native urine, was developed. Doping control samples of 499 athletes were analysed, and AICAR concentrations in urine were determined. The mean AICAR value for all samples was 2,186 ng/mL with a standard deviation of 1,655 ng/mL. Concentrations were found to differ depending on gender, type of sport and type of sample collection (in competition/out of competition). The method was fully validated for quantitative purposes considering the parameters linearity, inter- (12%, 7% and 10%) and intraday precision (14%, 9% and 12%) at low, mid and high concentration, robustness, accuracy (approx. 100%), limit of quantification (100 ng/mL), stability and ion suppression effects, employing an in-house synthesised (13)C(5)-labelled AICAR as internal standard.
Hatami, Mehdi; Farhadi, Khalil; Abdollahpour, Assem
2011-11-01
A simple, rapid, and efficient method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-fluorescence detector, has been developed for the determination of guaifenesin (GUA) enantiomers in human urine samples after an oral dose administration of its syrup formulation. Urine samples were collected during the time intervals 0-2, 2-4, and 4-6 h and concentration and ratio of two enantiomers was determined. The ratio of R-(-) to S-(+) enantiomer concentrations in urine showed an increase with time, with R/S ratios of 0.66 at 2 h and 2.23 at 6 h. For microextraction process, a mixture of extraction solvent (dichloromethane, 100 μL) and dispersive solvent (THF, 1 mL) was rapidly injected into 5.0 mL diluted urine sample for the formation of cloudy solution and extraction of enantiomers into the fine droplets of CH(2)Cl(2). After optimization of HPLC enantioselective conditions, some important parameters, such as the kind and volume of extraction and dispersive solvents, extraction time, temperature, pH, and salt effect were optimized for dispersive liquid-liquid microextraction process. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 10 to 2000 ng/mL for target analytes. LOD was 3.00 ng/mL for both of the enantiomers. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Goodrich, Jaclyn M.; Wang, Yi; Gillespie, Brenda; Werner, Robert; Franzblau, Alfred; Basu, Niladri
2012-01-01
Mercury is a potent toxicant of concern to both the general public and occupationally exposed workers (e.g., dentists). Recent studies suggest that several genes mediating the toxicokinetics of mercury are polymorphic in humans and may influence inter-individual variability in mercury accumulation. This work hypothesizes that polymorphisms in key glutathione synthesizing enzyme, glutathione s-transferase, and selenoprotein genes underlie inter-individual differences in mercury body burden as assessed by analytical mercury measurement in urine and hair, biomarkers of elemental mercury and methylmercury, respectively. Urine and hair samples were collected from a population of dental professionals (n=515), and total mercury content was measured. Average urine (1.06±1.24 ug/L) and hair mercury levels (0.49±0.63 ug/g) were similar to national U.S. population averages. Taqman assays were used to genotype DNA from buccal swab samples at 15 polymorphic sites in genes implicated in mercury metabolism. Linear regression modeling assessed the ability of polymorphisms to modify the relationship between mercury biomarker levels and exposure sources (e.g., amalgams, fish consumption). Five polymorphisms were significantly associated with urine mercury levels (GSTT1 deletion), hair mercury levels (GSTP1-105, GSTP1-114, GSS 5’), or both (SEPP1 3’UTR). Overall, this study suggests that polymorphisms in selenoproteins and glutathione-related genes may influence elimination of mercury in the urine and hair or mercury retention following exposures to elemental mercury (via dental amalgams) and methylmercury (via fish consumption). PMID:21967774
Kanaze, Feras Imad; Kokkalou, Eugene; Georgarakis, Manolis; Niopas, Ioannis
2004-09-21
A simple, specific, precise, accurate, and robust HPLC assay for the simultaneous analysis of hesperetin and naringenin in human urine was developed and validated. Urine samples were incubated with beta-glucuronidase/sulphatase and the analytes were isolated by solid-phase extraction using C18 cartridges and separated on a C8 reversed phase column using a mixture of methanol/water/acetic acid (40:58:2, v/v/v) at 45 degrees C. The method was found to be linear in the 50-1200 ng/ml concentration range for both hesperetin and naringenin (r > 0.999). The accuracy of the method was greater than 94.8%, while the intra- and inter-day precision for hesperetin was better than 4.9 and 8.2%, respectively and for naringenin was better than 5.3 and 7.8%, respectively. Recovery for hesperetin, naringenin and internal standard 7-ethoxycoumarin was greater than 70.9%. The method has been applied for the determination of hesperetin and naringenin in urine samples obtained from a male volunteer following a single 300 mg oral dose of each of the corresponding flavanone glycosides hesperidin and naringin. The intra- and inter-day reproducibility through enzyme hydrolysis was less than 3.9% for both total (free + conjugated) hesperetin and naringenin. Stability studies showed urine quality control samples to be stable for both hesperetin and naringenin through three freeze-thaw cycles and at room temperature for 24 h (error < or = 3.6%).
Ahmed, Hytham M; Ebeid, Wael B
2015-05-15
Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200ng/ml respectively and recovery was >98% (n=5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period. Copyright © 2015 Elsevier B.V. All rights reserved.
Fabresse, Nicolas; Allard, Julien; Sardaby, Marine; Thompson, Adrian; Clutton, R Eddie; Eddleston, Michael; Alvarez, Jean-Claude
2017-08-15
Clinical evaluation of a colchicine specific antigen-binding fragment (Fab) in order to treat colchicine poisoning required the development of an accurate method allowing quantification of free and Fab-bound colchicine in plasma and urine, and free colchicine in tissues, to measure colchicine redistribution after Fab administration. Three methods have been developed for this purpose, and validated in plasma, urine and liver: total colchicine was determined after denaturation of Fab by dilution in water and heating; free colchicine was separated from Fab-bound colchicine by filtration with 30KDa micro-filters; tissues were homogenized in a tissue mixer. Deuterated colchicine was used as internal standard. Samples were extracted by liquid-liquid extraction and analyzed with a LC-MS/MS. LOQ were 0.5ng/mL in plasma and urine for free and total colchicine and 5pg/mg in tissues. The methods were linear in the 0.5-100ng/mL range in plasma and urine, and 5-300pg/mg in tissues with determination coefficients>0.99. Precision and accuracy of QC samples presented a CV<9.4%. The methods require only 200μL of sample and allow a high throughput due to short analytical run (2min). These methods were successfully applied to a pig intoxicated with colchicine and treated with colchicine specific Fab fragments. Copyright © 2017 Elsevier B.V. All rights reserved.
Naccarato, Attilio; Gionfriddo, Emanuela; Sindona, Giovanni; Tagarelli, Antonio
2014-01-31
The work aims at developing a simple and rapid method for the quantification of dopamine (DA), serotonin (5-HT) and norepinephrine (NE) in human urine. The urinary levels of these biogenic amines can be correlated with several pathological conditions concerning heart disease, stress, neurological disorders and cancerous tumors. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) after a fast derivatization of both aliphatic amino and phenolic moieties by propyl chloroformate. The variables influencing the derivatization reaction were reliably optimized by the multivariate approach of "Experimental design". The optimal conditions were obtained by performing derivatization with 100μL of propyl chloroformate and 100μL of pyridine. The extraction ability of five commercially available SPME fibers was evaluated in univariate mode and the best results were obtained using the polyacrylate fiber. The variables affecting the efficiency of SPME analysis were again optimized by the multivariate approach of "Experimental design" and, in particular, a central composite design (CCD) was applied. The optimal values were extraction in 45min at room temperature, desorption temperature at 300°C, no addition of NaCl. Assay of derivatized analytes was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) system in selected reaction monitoring (SRM) acquisition. An evaluation of all analytical parameters demonstrates that the developed method provides satisfactory results. Indeed, very good linearities were achieved in the tested calibration range with correlation coefficient values of 0.9995, 0.9999 and 0.9997 for DA, 5-HT and NE, respectively. Accuracies and RSDs calculated for between-run and tested at concentrations of 30, 200, and 800μg L(-1) were in the range from 92.8% to 103.0%, and from 0.67 to 4.5%, respectively. Finally, the LOD values obtained can be considered very good (0.587, 0.381 and 1.23μg L(-1) for DA, 5-HT and NE, respectively). Copyright © 2013 Elsevier B.V. All rights reserved.
Interpretation of analytical toxicology results in life and at postmortem.
Flanagan, Robert J; Connally, Geraldine
2005-01-01
Interpretation of analytical toxicology results from live patients is sometimes difficult. Possible factors may be related to: (i) the nature of the poison(s) present; (ii) sample collection, transport and storage; (iii) the analytical methodology used; (iv) the circumstances of exposure; (v) mechanical factors such as trauma or inhalation of stomach contents; and (vi) pharmacological factors such as tolerance or synergy. In some circumstances, detection of a drug or other poison may suffice to prove exposure. At the other extreme, the interpretation of individual measurements may be simplified by regulation. Examples here include whole blood alcohol (ethanol) in regard to driving a motor vehicle and blood lead assays performed to assess occupational exposure. With pharmaceuticals, the plasma or serum concentrations of drugs and metabolites attained during treatment often provide a basis for the interpretation of quantitative measurements. With illicit drugs, comparative information from casework may be all that is available. Postmortem toxicology is an especially complex area since changes in the composition of fluids such as blood depending on the site of collection from the body and the time elapsed since death, amongst other factors, may influence the result obtained. This review presents information to assist in the interpretation of analytical results, especially regarding postmortem toxicology. Collection and analysis of not only peripheral blood, but also other fluids/tissues is usually important in postmortem work. Alcohol, for example, can be either lost from, or produced in, blood especially if there has been significant trauma, hence measurements in urine or vitreous humour are needed to confirm the reliability of a blood result. Measurement of metabolites may also be valuable in individual cases.
Quality of dry chemistry testing.
Nakamura, H; Tatsumi, N
1999-01-01
Since the development of the qualitative test paper for urine in 1950s, several kinds of dry-state-reagents and their automated analyzers have been developed. "Dry chemistry" has become to be called since the report on the development of quantitative test paper for serum bilirubin with reflectometer in the end of 1960s and dry chemistry has been world widely known since the presentation on the development of multilayer film reagent for serum biochemical analytes by Eastman Kodak Co at the 10th IFCC Meeting in the end of 1970s. We have reported test menu, results in external quality assessment, merits and demerits, and the future possibilities of dry chemistry.
Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine
2013-01-01
Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining (1)H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after (1)H NMR spectroscopy. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at -20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions.
Farajzadeh, Mir Ali; Nouri, Nina; Alizadeh Nabil, Ali Akbar
2013-12-01
A one-step derivatization and microextraction technique for the determination of amantadine in the human plasma and urine samples is presented. An appropriate mixture of methanol (disperser solvent), 1,2-dibromoethane (extraction solvent), and butylchloroformate (derivatization agent) is rapidly injected into samples. After centrifuging, the sedimented phase is analyzed by gas chromatography-flame ionization detection (GC-FID). The kind of extraction and disperser solvents and their volumes, amount of derivatization agent and reaction/extraction time which are effective in derivatization/dispersive liquid-liquid microextraction (DLLME) procedure are optimized. Under the optimal conditions, the enrichment factor (EF) of the target analyte was obtained to be 408 and 420, and limit of detection (LOD) 4.2 and 2.7ngmL(-1), in plasma and urine respectively. The linear range is 14-5000 and 8.7-5000ng/mL for plasma and urine, respectively (squared correlation coefficient≥0.990). The relative recoveries obtained for the spiked plasma and urine samples are between 72% and 93%. Moreover, the inter- and intra-day precisions are acceptable at all spiked concentrations (relative standard deviation <7%). Finally the method was successfully applied to determine amantadine in biological samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Zhang, Jiaheng; Gao, Haixiang; Peng, Bing; Li, Yubo; Li, Songqing; Zhou, Zhiqiang
2012-01-15
A novel pretreatment method termed ultrasound-assisted dispersive liquid-liquid microextraction (UADLLME) coupled with high-performance liquid chromatography-ultraviolet detector (HPLC-UV) was applied for the detection of four synthesized metabolites of mequindox in pig urine samples. A total volume of 200 μL of methanol (dispersant) and 60 μL of 1,1,2,2-tetrachloroethane (extract) were injected into 5.0 mL of urine sample and then emulsified by ultrasound treatment for 4 min to form a cloudy solution. The effect of several factors on the recovery of each metabolite was investigated by a fitting derivation method for the first time. Under optimum conditions, the method yields a linear calibration curve in the concentration range from 0.5 to 500 μg/L and a limit of detection (LOD) of 0.16-0.28 μg/L for target analytes. The recoveries ranged from 72.0% to 91.3% with a relative standard deviation (RSD) of less than 5.2%. The enrichment factors for the four compounds ranged from 75 to 95. Two pig urine samples were successfully analyzed using the proposed method. Copyright © 2011 Elsevier B.V. All rights reserved.