Sample records for urine monitoring system

  1. Urine Monitoring System

    NASA Technical Reports Server (NTRS)

    Feedback, Daniel L.; Cibuzar, Branelle R.

    2009-01-01

    The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.

  2. [Development of automatic urine monitoring system].

    PubMed

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  3. STS-40 Exp. No. 192 urine monitoring system (UMS) on OV-102's middeck

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-40 Experiment No. 192, Fluid-Electrolyte Regulation During Space Flight, urine monitoring system (UMS) is set up on the middeck of Columbia, Orbiter Vehicle (OV) 102, at the side hatch. The UMS is attached to OV-102's waste collection system (WCS). The urine specimen tray with sample tubes appears to the right of the UMS equipment.

  4. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriguez, Branelle R.; Broyan, James Lee, Jr.

    2008-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  5. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Cibuzar, Branelle R.; Broyan, James Lee, Jr.

    2009-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  6. STS-40 Exp. No. 192 urine monitoring system (UMS) on OV-102's middeck

    NASA Image and Video Library

    1991-06-14

    STS040-04-036 (5-14 June 1991) --- Closeup view of urine monitoring system and test samples, part of the busy schedule of life sciences testing on the nine-day STS-40/Spacelab Life Sciences (SLS-1) mission aboard the earth-orbiting Columbia.

  7. Development of an Inline Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Banelle R.

    2008-01-01

    Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

  8. Modular biowaste monitoring system

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.

    1975-01-01

    The objective of the Modular Biowaste Monitoring System Program was to generate and evaluate hardware for supporting shuttle life science experimental and diagnostic programs. An initial conceptual design effort established requirements and defined an overall modular system for the collection, measurement, sampling and storage of urine and feces biowastes. This conceptual design effort was followed by the design, fabrication and performance evaluation of a flight prototype model urine collection, volume measurement and sampling capability. No operational or performance deficiencies were uncovered as a result of the performance evaluation tests.

  9. Development of an In-line Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Branelle R.

    2009-01-01

    Exposure to microgravity during space flight causes bone loss when calcium and other metabolic by-products are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is thus essential in determining crew bone loss and the effectiveness of the countermeasures that are taken to minimize this loss. Earlier space shuttle Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to the cross-contamination that took place between users, as well as to fluid system instabilities. Crew urine voids are currently collected manually in a flexible plastic bag that contains a known tracer quantity. A crew member must completely mix the contents of this bag before withdrawing a representative syringe sample for later ground analysis. The existing bag system accuracy is therefore highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures void volume, and allows for syringe sampling. After the ISS UMS has been used by a crew member, it delivers urine to the WHC for normal processing. The UMS plumbing is then flushed with a small volume of water. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, consequently greatly reducing cross-contamination among urine voids (less than 0.5 mL urine) while also providing accurate volume measurements (less than 2 percent error for 100 to 1,000 mL void volumes). ISS UMS performance has been validated through extensive ground tests and reduced-gravity aircraft flights. The locker-sized ISS UMS is currently undergoing a design modification that will permit it to interface with the ISS Node 3 WHC Russian toilet (ACY) hardware. The operating principles, characteristics, and results of this design modification are outlined here.

  10. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle R.; Broyan, James Lee, Jr.

    2011-01-01

    Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

  11. Urinary Biomarkers of Brain Diseases

    PubMed Central

    An, Manxia; Gao, Youhe

    2016-01-01

    Biomarkers are the measurable changes associated with a physiological or pathophysiological process. Unlike blood, urine is not subject to homeostatic mechanisms. Therefore, greater fluctuations could occur in urine than in blood, better reflecting the changes in human body. The roadmap of urine biomarker era was proposed. Although urine analysis has been attempted for clinical diagnosis, and urine has been monitored during the progression of many diseases, particularly urinary system diseases, whether urine can reflect brain disease status remains uncertain. As some biomarkers of brain diseases can be detected in the body fluids such as cerebrospinal fluid and blood, there is a possibility that urine also contain biomarkers of brain diseases. This review summarizes the clues of brain diseases reflected in the urine proteome and metabolome. PMID:26751805

  12. Evaluation of Digital PCR as a Technique for Monitoring Acute Rejection in Kidney Transplantation.

    PubMed

    Lee, Hyeseon; Park, Young-Mi; We, Yu-Mee; Han, Duck Jong; Seo, Jung-Woo; Moon, Haena; Lee, Yu-Ho; Kim, Yang-Gyun; Moon, Ju-Young; Lee, Sang-Ho; Lee, Jong-Keuk

    2017-03-01

    Early detection and proper management of kidney rejection are crucial for the long-term health of a transplant recipient. Recipients are normally monitored by serum creatinine measurement and sometimes with graft biopsies. Donor-derived cell-free deoxyribonucleic acid (cfDNA) in the recipient's plasma and/or urine may be a better indicator of acute rejection. We evaluated digital PCR (dPCR) as a system for monitoring graft status using single nucleotide polymorphism (SNP)-based detection of donor DNA in plasma or urine. We compared the detection abilities of the QX200, RainDrop, and QuantStudio 3D dPCR systems. The QX200 was the most accurate and sensitive. Plasma and/or urine samples were isolated from 34 kidney recipients at multiple time points after transplantation, and analyzed by dPCR using the QX200. We found that donor DNA was almost undetectable in plasma DNA samples, whereas a high percentage of donor DNA was measured in urine DNA samples, indicating that urine is a good source of cfDNA for patient monitoring. We found that at least 24% of the highly polymorphic SNPs used to identify individuals could also identify donor cfDNA in transplant patient samples. Our results further showed that autosomal, sex-specific, and mitochondrial SNPs were suitable markers for identifying donor cfDNA. Finally, we found that donor-derived cfDNA measurement by dPCR was not sufficient to predict a patient's clinical condition. Our results indicate that donor-derived cfDNA is not an accurate predictor of kidney status in kidney transplant patients.

  13. Integrated water management system - Description and test results. [for Space Station waste water processing

    NASA Technical Reports Server (NTRS)

    Elden, N. C.; Winkler, H. E.; Price, D. F.; Reysa, R. P.

    1983-01-01

    Water recovery subsystems are being tested at the NASA Lyndon B. Johnson Space Center for Space Station use to process waste water generated from urine and wash water collection facilities. These subsystems are being integrated into a water management system that will incorporate wash water and urine processing through the use of hyperfiltration and vapor compression distillation subsystems. Other hardware in the water management system includes a whole body shower, a clothes washing facility, a urine collection and pretreatment unit, a recovered water post-treatment system, and a water quality monitor. This paper describes the integrated test configuration, pertinent performance data, and feasibility and design compatibility conclusions of the integrated water management system.

  14. Determination of urine-derived odorous compounds in a source separation sanitation system.

    PubMed

    Liu, Bianxia; Giannis, Apostolos; Chen, Ailu; Zhang, Jiefeng; Chang, Victor W C; Wang, Jing-Yuan

    2017-02-01

    Source separation sanitation systems have attracted more and more attention recently. However, separate urine collection and treatment could induce odor issues, especially in large scale application. In order to avoid such issues, it is necessary to monitor the odor related compounds that might be generated during urine storage. This study investigated the odorous compounds that emitted from source-separated human urine under different hydrolysis conditions. Batch experiments were conducted to investigate the effect of temperature, stale/fresh urine ratio and urine dilution on odor emissions. It was found that ammonia, dimethyl disulfide, allyl methyl sulfide and 4-heptanone were the main odorous compounds generated from human urine, with headspace concentrations hundreds of times higher than their respective odor thresholds. Furthermore, the high temperature accelerated urine hydrolysis and liquid-gas mass transfer, resulting a remarkable increase of odor emissions from the urine solution. The addition of stale urine enhanced urine hydrolysis and expedited odor emissions. On the contrary, diluted urine emitted less odorous compounds ascribed to reduced concentrations of odorant precursors. In addition, this study quantified the odor emissions and revealed the constraints of urine source separation in real-world applications. To address the odor issue, several control strategies are recommended for odor mitigation or elimination from an engineering perspective. Copyright © 2016. Published by Elsevier B.V.

  15. Urinary Biomarkers of Brain Diseases.

    PubMed

    An, Manxia; Gao, Youhe

    2015-12-01

    Biomarkers are the measurable changes associated with a physiological or pathophysiological process. Unlike blood, urine is not subject to homeostatic mechanisms. Therefore, greater fluctuations could occur in urine than in blood, better reflecting the changes in human body. The roadmap of urine biomarker era was proposed. Although urine analysis has been attempted for clinical diagnosis, and urine has been monitored during the progression of many diseases, particularly urinary system diseases, whether urine can reflect brain disease status remains uncertain. As some biomarkers of brain diseases can be detected in the body fluids such as cerebrospinal fluid and blood, there is a possibility that urine also contain biomarkers of brain diseases. This review summarizes the clues of brain diseases reflected in the urine proteome and metabolome. Copyright © 2016 The Authors. Production and hosting by Elsevier Ltd.. All rights reserved.

  16. The International Space Station Urine Monitoring System (UMS)

    NASA Technical Reports Server (NTRS)

    Feeback, Daniel L.; Cibuzar, Branelle R.; Milstead, Jeffery R.; Pietrzyk,, Robert A.; Clark, Mark S.F.

    2009-01-01

    A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification completed prior to placing the instrument into operation. Samples collected during the verification sequence will be returned for analyses on STS-131 (19A) currently scheduled for launch in March 2010. The presence of a UMS on ISS will provide the capability to conduct additional collaborative human life science investigations among the ISS International Partners.

  17. Validation of Procedures for Monitoring Crewmember Immune Function - Short Duration Biological Investigation

    NASA Technical Reports Server (NTRS)

    Sams, Clarence; Crucian, Brian; Stowe, Raymond; Pierson, Duane; Mehta, Satish; Morukov, Boris; Uchakin, Peter; Nehlsen-Cannarella, Sandra

    2008-01-01

    Validation of Procedures for Monitoring Crew Member Immune Function - Short Duration Biological Investigation (Integrated Immune-SDBI) will assess the clinical risks resulting from the adverse effects of space flight on the human immune system and will validate a flightcompatible immune monitoring strategy. Immune system changes will be monitored by collecting and analyzing blood, urine and saliva samples from crewmembers before, during and after space flight.

  18. Correlation of Urine Biomarkers: Microalbuminuria and Spot Urine Protein among Diabetic Patients. Application of Spot Urine Protein in Diabetic Kidney Disease, Nephropathy, Proteinuria Estimation, Diagnosing and Monitoring.

    PubMed

    Aziz, Kamran M A

    2015-01-01

    Current study has invented a new method for utilizing spot urine protein among diabetic patients. There have been various efforts and strategies in research internationally to detect, diagnose and monitor nephropathy/DKD. Although 24-hour urine studies are gold standard, however, there exist some controversies about microalbuminuria and spot urine protein. The current study was designed to utilize spot urine protein among diabetic patients and to find its association with routine dipstick urine test for albumin, and microalbuminuria. The study demonstrated significant association of spot urine protein with urine dipstick albumin, and has demonstrated increasing spot urine protein with increasing albumin in urine (p-value < 0.0001). This study also demonstrated significantly higher levels of spot urine protein between the groups with nephropathy/DKD as compared to those without nephropathy/DKD (p-value < 0.0001). Similarly, spot urine protein and spot urine protein/creatinine were also significantly associated with microalbumin and microalbumin/creatinine in urine. Significant regression models for spot urine protein and microalbuminuria were also developed and proposed to detect and estimate microalbumin in urine while utilizing spot urine protein (< 0.0001). Synthesized regression equations and models can be used confidently to detect, rule out and monitor proteinuria and DKD. ROC curves were utilized to detect spot urine protein cutoff points for nephropathy and DKD with high specificity and sensitivity. Some important patents were also discussed in the paper regarding albuminuria/proteinuria detection and management. Current study has demonstrated and concluded, for the first time, that there exists a significant association of spot urine protein with routine dipstick albumin in urine and microalbuminuria. It is also essential to detect early, monitor and manage proteinuria, hypertension and dyslipidemia with good glycemic control to prevent diabetes complications.

  19. Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure

    PubMed Central

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2018-01-01

    Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162

  20. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    PubMed

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  1. Explaining engagement in self-monitoring among participants of the DESMOND Self-monitoring Trial: a qualitative interview study

    PubMed Central

    Eborall, Helen C; Dallosso, Helen M; McNicol, Sarah; Speight, Jane; Khunti, Kamlesh; Davies, Melanie J; Heller, Simon R

    2015-01-01

    Abstract Background. The Diabetes Education and Self-Management for Ongoing and Newly Diagnosed (DESMOND) Self-monitoring Trial reported that people with newly diagnosed type 2 diabetes attending community-based structured education and randomized to self-monitoring of blood glucose (SMBG) or urine monitoring had comparable improvements in biomedical outcomes, but differences in satisfaction with, and continued use of monitoring method, well-being and perceived threat from diabetes. Objectives. To explore experiences of SMBG and urine monitoring following structured education. We specifically addressed the perceived usefulness of each monitoring method and the associated well-being. Methods. Qualitative semi-structured interviews with 18 adults with newly diagnosed type 2 diabetes participating in the DESMOND Self-monitoring Trial (SMBG, N = 10; urine monitoring, N = 8) ~12 months into the trial. Analysis was informed by the constant comparative approach. Results. Interviewees reported SMBG as accurate, convenient and useful. Declining use was explained by having established a pattern of managing blood glucose with less frequent monitoring or lack of feedback or encouragement from health care professionals. Many initially positive views of urine monitoring progressively changed due to perceived inaccuracy, leading some to switch to SMBG. Perceiving diabetes as less serious was attributable to lack of symptoms, treatment with diet alone and—in the urine-monitoring group—consistently negative readings. Urine monitoring also provided less visible evidence of diabetes and of the effect of behaviour on glucose. Conclusions. The findings highlight the importance for professionals of considering patients’ preferences when using self-monitoring technologies, including how these change over time, when supporting the self-care behaviours of people with type 2 diabetes. PMID:26160892

  2. Spatially and temporally variable urinary N loads deposited by lactating cows on a grazing system dairy farm.

    PubMed

    Ahmed, Awais; Sohi, Rajneet; Roohi, Rakhshan; Jois, Markandeya; Raedts, Peter; Aarons, Sharon R

    2018-06-01

    Feed nitrogen (N) intakes in Australian grazing systems average 545 g cow -1 day -1 , indicating that urinary N is likely to be the dominant form excreted. Grazing animals spend disproportionate amounts of time in places on dairy farms where N accumulation is likely to occur. We attached to grazing cows sensors that measure urine volume and N concentration, as well as global positioning systems sensors used to monitor the times the cows spent in different places on a farm and the location of urination events. The cows were monitored for up to 72 h in each of two seasons. More urination events and greater urine volumes per event were recorded in spring 2014 (3.1 L) compared with winter 2015 (1.4 L), most likely influenced by environmental conditions and the greater spring rainfall observed. Mean (range) N concentration (0.71%; 0.02 to 1.52%) and N load (12.8 g cow -1 event -1 ; 0.3 to 64.5 g cow -1 event -1 ) did not differ over the two monitoring periods. However, mean (range) daily N load was greater in spring (277 g cow -1 day -1 ; 200 to 346 g cow -1 day -1 ) than in winter (90 g cow -1 day -1 ; 44 to 116 g cow -1 day -1 ) due to the influence of urine volume. Relatively greater time was spent in paddocks overnight (13.3 h) than in paddocks between morning and evening milking (6.4 h), compared with the mean numbers of urinations in these places (6.4 and 3.8 respectively). The mean N load deposited overnight in paddocks (89.6 g cow -1 ) was more than twice that deposited in paddocks during the day (43.8 g cow -1 ), due to the greater N load per event overnight, and was more closely linked to the relative difference in time spent in paddocks than in the number of urination events. These data suggest that routinely holding cows in the same paddocks overnight will lead to high urinary N depositions, increasing the potential for N losses from these places. Further research using this technology is required to acquire farm and environment specific urinary data to improve N management. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. [A study of biomechanical method for urine test based on color difference estimation].

    PubMed

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Zhou, Fengkun

    2008-02-01

    The biochemical analysis of urine is an important inspection and diagnosis method in hospitals. The conventional method of urine analysis covers mainly colorimetric visual appraisement and automation detection, in which the colorimetric visual appraisement technique has been superseded basically, and the automation detection method is adopted in hospital; moreover, the price of urine biochemical analyzer on market is around twenty thousand RMB yuan (Y), which is hard to enter into ordinary families. It is known that computer vision system is not subject to the physiological and psychological influence of person, its appraisement standard is objective and steady. Therefore, according to the color theory, we have established a computer vision system, which can carry through collection, management, display, and appraisement of color difference between the color of standard threshold value and the color of urine test paper after reaction with urine liquid, and then the level of an illness can be judged accurately. In this paper, we introduce the Urine Test Biochemical Analysis method, which is new and can be popularized in families. Experimental result shows that this test method is easy-to-use and cost-effective. It can realize the monitoring of a whole course and can find extensive applications.

  4. Microbiological and corrosion analysis of three urine pretreatment regimes with titanium 6A1-4V

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1993-01-01

    One objective of the water recovery test (WRT) performed at NASA's Marshall Space Flight Center (MSFC) for the environmental control and life support systems (ECLSS) of Space Station Freedom is to determine the ability of the water recovery system to reclaim urine for crew reuse. In the process, raw urine is pretreated using a commercially available oxidant, Oxone (Dupont), and sulfuric acid (to reduce ammonia), and pumped into a urine processing subsystem. A combination of sodium hypochlorite and sulfuric acid were also considered as an alternative pretreatment. The ability of these pretreatments, plus a third pretreatment of ozone, to reduce microbial levels in urine generated during testing of the water recovery system at MSFC was examined. In addition, the corrosion rate of weld and base metal specimens of titanium 6A1-4V, a candidate material for the water system of Space Station Freedom, was monitored in the presence of these pretreatments. Specimen surfaces were examined at completion of the 21-day test using scanning electron microscopy. Change in pH, color, turbidity, and odor were recorded over the course of the test.

  5. Development of a near-infrared spectroscopic system for monitoring urine glucose level for the use of long-term home healthcare

    NASA Astrophysics Data System (ADS)

    Tanaka, Shinobu; Hayakawa, Yuuto; Ogawa, Mitsuhiro; Yamakoshi, Ken-ichi

    2010-08-01

    We have been developing a new technique for measuring urine glucose concentration using near infrared spectroscopy (NIRS) in conjunction with the Partial Least Square (PLS) method. In the previous study, we reported some results of preliminary experiments for assessing feasibility of this method using a FT-IR spectrometer. In this study, considering practicability of the system, a flow-through cell with the optical path length of 10 mm was newly introduced. Accuracy of the system was verified by the preliminary experiments using urine samples. From the results obtained, it was clearly demonstrated that the present method had a capability of predicting individual urine glucose level with reasonable accuracy (the minimum value of standard error of prediction: SEP = 22.3 mg/dl) and appeared to be a useful means for long-term home health care. However, mean value of SEP obtained by the urine samples from ten subjects was not satisfactorily low (53.7 mg/dl). For improving the accuracy, (1) mechanical stability of the optical system should be improved, (2) the method for normalizing the spectrum should be reconsidered, and (3) the number of subject should be increased.

  6. International Space Station (ISS)

    NASA Image and Video Library

    2001-02-01

    The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. This photograph shows the fifth generation Urine Processor Development Hardware. The Urine Processor Assembly (UPA) is a part of the Water Recovery System (WRS) on the ISS. It uses a chase change process called vapor compression distillation technology to remove contaminants from urine. The UPA accepts and processes pretreated crewmember urine to allow it to be processed along with other wastewaters in the Water Processor Assembly (WPA). The WPA removes free gas, organic, and nonorganic constituents before the water goes through a series of multifiltration beds for further purification. Product water quality is monitored primarily through conductivity measurements. Unacceptable water is sent back through the WPA for reprocessing. Clean water is sent to a storage tank.

  7. Chemical Sensor Platform for Non-Invasive Monitoring of Activity and Dehydration

    PubMed Central

    Solovei, Dmitry; Žák, Jaromír; Majzlíková, Petra; Sedláček, Jiří; Hubálek, Jaromír

    2015-01-01

    A non-invasive solution for monitoring of the activity and dehydration of organisms is proposed in the work. For this purpose, a wireless standalone chemical sensor platform using two separate measurement techniques has been developed. The first approach for activity monitoring is based on humidity measurement. Our solution uses new humidity sensor based on a nanostructured TiO2 surface for sweat rate monitoring. The second technique is based on monitoring of potassium concentration in urine. High level of potassium concentration denotes clear occurrence of dehydration. Furthermore, a Wireless Body Area Network (WBAN) was developed for this sensor platform to manage data transfer among devices and the internet. The WBAN coordinator controls the sensor devices and collects and stores the measured data. The collected data is particular to individuals and can be shared with physicians, emergency systems or athletes' coaches. Long-time monitoring of activity and potassium concentration in urine can help maintain the appropriate water intake of elderly people or athletes and to send warning signals in the case of near dehydration. The created sensor system was calibrated and tested in laboratory and real conditions as well. The measurement results are discussed. PMID:25594591

  8. Quantitative Monitoring of Cefradine in Human Urine Using a Luminol/Sulfobutylether-β-Cyclodextrin Chemiluminescence System

    NASA Astrophysics Data System (ADS)

    Shen, M. X.; Tan, X. J.; Song, Zh. H.

    2018-05-01

    In this paper, a sensitive, rapid, and simple flow-injection chemiluminescence (FI-CL) technique is described for determining cefradine in human urine and capsule samples at the picogram level. The results show that cefradine within 0.1-100.0 nmol/L quantitatively quenches the CL intensity of the luminol/sulfo butylether-β-cyclodextrin (SBE-β-CD) system, with a relative correlation coefficient r of 0.9931. Subsequently, the possible mechanism for the quenching phenomenon is discussed in detail using the FI-CL and molecular docking methods. The proposed CL method, with a detection limit of 0.03 nmol/L (3σ) and relative standard deviations <3.0% (N = 7), is then implemented to monitor the excretion of cefradine in human urine. After orally administration, the cefradine reaches a maximum value of 1.37 ± 0.02 mg/mL at 2.0 h in urine, and the total excretion is 4.41 ± 0.03 mg/mL within 8.0 h. The absorption rate constant ka, the elimination rate constant ke, and the half-life t1/2 are 0.670 ± 0.008 h-1, 0.744 ± 0.005 h-1, and 0.93 ± 0.05 h, respectively.

  9. Mining the human urine proteome for monitoring renal transplant injury

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigdel, Tara K.; Gao, Yuqian; He, Jintang

    The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used inmore » the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.« less

  10. 21 CFR 862.1600 - Potassium test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Potassium test system. 862.1600 Section 862.1600....1600 Potassium test system. (a) Identification. A potassium test system is a device intended to measure potassium in serum, plasma, and urine. Measurements obtained by this device are used to monitor electrolyte...

  11. 21 CFR 862.1600 - Potassium test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Potassium test system. 862.1600 Section 862.1600....1600 Potassium test system. (a) Identification. A potassium test system is a device intended to measure potassium in serum, plasma, and urine. Measurements obtained by this device are used to monitor electrolyte...

  12. 21 CFR 862.1600 - Potassium test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Potassium test system. 862.1600 Section 862.1600....1600 Potassium test system. (a) Identification. A potassium test system is a device intended to measure potassium in serum, plasma, and urine. Measurements obtained by this device are used to monitor electrolyte...

  13. 21 CFR 862.1600 - Potassium test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Potassium test system. 862.1600 Section 862.1600....1600 Potassium test system. (a) Identification. A potassium test system is a device intended to measure potassium in serum, plasma, and urine. Measurements obtained by this device are used to monitor electrolyte...

  14. 21 CFR 862.1600 - Potassium test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Potassium test system. 862.1600 Section 862.1600....1600 Potassium test system. (a) Identification. A potassium test system is a device intended to measure potassium in serum, plasma, and urine. Measurements obtained by this device are used to monitor electrolyte...

  15. Environmental Control and Life Support Systems Testing Facility at MSFC

    NASA Technical Reports Server (NTRS)

    2001-01-01

    The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. This photograph shows the fifth generation Urine Processor Development Hardware. The Urine Processor Assembly (UPA) is a part of the Water Recovery System (WRS) on the ISS. It uses a chase change process called vapor compression distillation technology to remove contaminants from urine. The UPA accepts and processes pretreated crewmember urine to allow it to be processed along with other wastewaters in the Water Processor Assembly (WPA). The WPA removes free gas, organic, and nonorganic constituents before the water goes through a series of multifiltration beds for further purification. Product water quality is monitored primarily through conductivity measurements. Unacceptable water is sent back through the WPA for reprocessing. Clean water is sent to a storage tank.

  16. Urine monitoring system failure analysis and operational verification test report

    NASA Technical Reports Server (NTRS)

    Glanfield, E. J.

    1978-01-01

    Failure analysis and testing of a prototype urine monitoring system (UMS) are reported. System performance was characterized by a regression formula developed from volume measurement test data. When the volume measurement test data. When the volume measurement data was imputted to the formula, the standard error of the estimate calculated using the regression formula was found to be within 1.524% of the mean of the mass of the input. System repeatability was found to be somewhat dependent upon the residual volume of the system and the evaporation of fluid from the separator. The evaporation rate was determined to be approximately 1cc/minute. The residual volume in the UMS was determined by measuring the concentration of LiCl in the flush water. Observed results indicated residual levels in the range of 9-10ml, however, results obtained during the flushing efficiency test indicated a residual level of approximately 20ml. It is recommended that the phase separator pumpout time be extended or the design modified to minimize the residual level.

  17. UPT scenarios: Implications for system reliability

    NASA Technical Reports Server (NTRS)

    Walsh, Daniel W.

    1992-01-01

    The objective of this project was to examine the corrosion resistance of 316L stainless steel in several urine pre-treat solutions. Four solutions were examined: untreated urine (control); urine pretreated with oxone (potassium peroxymonosulfate sulfate); urine pretreated with sodium hypochlorite (NaOCl); and urine pretreated with ozone (O3). In accordance with current procedures, all solutions but the control were acidified to a pH of 2.5 using sulfuric acid--this suppresses the generation of ammonia in the solutions and is intended to limit microbial growth. Welded and unwelded coupons were exposed to each solution. In addition, Titanium coupons (welded and unwelded) were exposed to biologically active environmental control and life support system (ECLSS) water. Microbial attachment and biofilm growth were monitored. Ozone was examined as a biocide/oxidizer/corrosion preventative (simultaneous addition) and as a remediation method (added one week after exposure). In an unrelated effort, HP 9-4-30 coupons were exposed to biologically active solutions. Corrosion rates for welded and unwelded samples were determined--results were correlated to the ongoing HP 9-4-30 weldment stress corrosion study.

  18. Urine Creatinine Concentrations in Drug Monitoring Participants and Hospitalized Patients.

    PubMed

    Love, Sara A; Seegmiller, Jesse C; Kloss, Julie; Apple, Fred S

    2016-10-01

    Urine drug testing is commonly performed in both clinical and forensic arenas for screening, monitoring and compliance purposes. We sought to determine if urine creatinine concentrations in monitoring program participants were significantly different from hospital in-patients and out-patients undergoing urine drug testing. We retrospectively reviewed urine creatinine submitted in June through December 2015 for all specimens undergoing urine drug testing. The 20,479 creatinine results were categorized as hospitalized patients (H) and monitoring/compliance groups for pain management (P), legal (L) or recovery (R). Median creatinine concentrations (interquartile range, mg/dL) were significantly different (P < 0.001) between groups: H 126 (122-136); P 138 (137-143); L 147 (144-154); R 95 (92-97). In the two groups subject to on-demand sampling time pressures, median creatinine concentrations were significantly lower in the R vs. L group (P<0.001). In conclusion, recovery (R) participants have more dilute specimens, reflected by significantly lower creatinine concentration and may indicate participants' attempts to tamper with their drug test results through dilution means. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Biological monitoring of iodine, a water disinfectant for long-term space missions

    NASA Technical Reports Server (NTRS)

    Zareba, G.; Cernichiari, E.; Goldsmith, L. A.; Clarkson, T. W.

    1995-01-01

    In order to establish guidelines for exposure of astronauts to iodine, used as a water disinfectant in space, we studied the usefulness of hair, saliva, and urine for biological monitoring in humans and in the human hair/nude mouse model. The monitoring of iodine in patients that received 150 mCi of Na131I (carrier-free) showed similar patterns of elimination for blood, saliva, and urine. The mean correlation coefficient (r) between iodine elimination for blood/saliva was 0.99, for blood/urine, 0.95, and for saliva/urine, 0.97. The absolute value of iodine concentrations in urine revealed marked variability, which was corrected by adjusting for creatinine levels. The autoradiographic studies of human hair demonstrated that iodine is rapidly incorporated into external layers of the hair root and can be removed easily during washing. These data were confirmed after iodine exposure using the human hair/nude mouse model. Hair does not provide satisfactory information about exposure due to unstable incorporation of iodine. The most useful medium for biological monitoring of astronauts exposed to high doses of iodine in drinking water is urine, when adjusted for creatinine, and saliva, if quantitative evaluation of flow rate is provided.

  20. Development of urine glucose meter based on micro-planer amperometric biosensor and its clinical application for self-monitoring of urine glucose.

    PubMed

    Miyashita, Mariko; Ito, Narushi; Ikeda, Satoshi; Murayama, Tatsuro; Oguma, Koji; Kimura, Jun

    2009-01-01

    The highly sensitive urine glucose meter based on amperometric glucose sensor was developed and commercialized. It shows remarkable performances of wide measurement range in 0-2000 mgdl(-1), rapid response time as 6s and robustness against influence by interferents like ascorbic acid or acetaminophen. Correlation between the developed urine glucose meter and commercialized clinical-use urine glucose analyzer showed excellent linear relationship. The monitoring of postmeal blood glucose levels by assess of urine glucose of actual subjects was performed with the developed urine glucose meter. The experimental results suggest the urine glucose level 120 min following the meal should be the appropriate index for diabetes or impaired glucose tolerance to control blood glucose level. The new portable meter was developed, and is expected for flexible use at places other than home or office.

  1. Automated Microbiological Detection/Identification System

    PubMed Central

    Aldridge, C.; Jones, P. W.; Gibson, S.; Lanham, J.; Meyer, M.; Vannest, R.; Charles, R.

    1977-01-01

    An automated, computerized system, the AutoMicrobic System, has been developed for the detection, enumeration, and identification of bacteria and yeasts in clinical specimens. The biological basis for the system resides in lyophilized, highly selective and specific media enclosed in wells of a disposable plastic cuvette; introduction of a suitable specimen rehydrates and inoculates the media in the wells. An automated optical system monitors, and the computer interprets, changes in the media, with enumeration and identification results automatically obtained in 13 h. Sixteen different selective media were developed and tested with a variety of seeded (simulated) and clinical specimens. The AutoMicrobic System has been extensively tested with urine specimens, using a urine test kit (Identi-Pak) that contains selective media for Escherichia coli, Proteus species, Pseudomonas aeruginosa, Klebsiella-Enterobacter species, Serratia species, Citrobacter freundii, group D enterococci, Staphylococcus aureus, and yeasts (Candida species and Torulopsis glabrata). The system has been tested with 3,370 seeded urine specimens and 1,486 clinical urines. Agreement with simultaneous conventional (manual) cultures, at levels of 70,000 colony-forming units per ml (or more), was 92% or better for seeded specimens; clinical specimens yielded results of 93% or better for all organisms except P. aeruginosa, where agreement was 86%. System expansion in progress includes antibiotic susceptibility testing and compatibility with most types of clinical specimens. Images PMID:334798

  2. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing

    PubMed Central

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  3. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.

    PubMed

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-05-17

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.

  4. Sodium urine test

    MedlinePlus

    ... or monitor many types of kidney diseases. Normal Results For adults, normal urine sodium values are generally ... meaning of your specific test result. What Abnormal Results Mean A higher than normal urine sodium level ...

  5. Biowaste monitoring system for shuttle

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Sauer, R. L.

    1975-01-01

    The acquisition of crew biomedical data has been an important task on all manned space missions from Project Mercury through the recently completed Skylab Missions. The monitoring of metabolic wastes from the crew is an important aspect of this activity. On early missions emphasis was placed on the collection and return of biowaste samples for post-mission analysis. On later missions such as Skylab, equipment for inflight measurement was also added. Life Science experiments are being proposed for Shuttle missions which will require the inflight measurement and sampling of metabolic wastes. In order to minimize the crew impact associated with these requirements, a high degree of automation of these processes will be required. This paper reviews the design and capabilities of urine biowaste monitoring equipment provided on past-manned space programs and defines and describes the urine volume measurement and sampling equipment planned for the Shuttle Orbiter program.

  6. Environmental Control and Life Support Systems Testing Facility at MSFC

    NASA Technical Reports Server (NTRS)

    2001-01-01

    The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. This photograph shows the Urine Processor Assembly (UPA) which utilizes the Vapor Compression Distillation (VCD) technology. The VCD is used for integrated testing of the entire Water Recovery System (WRS) and development testing of the Urine Processor Assembly. The UPA accepts and processes pretreated crewmember urine to allow it to be processed along with other wastewaters in the Water Processor Assembly (WPA). The WPA removes free gas, organic, and nonorganic constituents before the water goes through a series of multifiltration beds for further purification. Product water quality is monitored primarily through conductivity measurements. Unacceptable water is sent back through the WPA for reprocessing. Clean water is sent to a storage tank.

  7. Cytology exam of urine

    MedlinePlus

    Urine cytology; Bladder cancer - cytology; Urethral cancer - cytology; Renal cancer - cytology ... The test is done to detect cancer of the urinary tract. It is often done when blood is seen in the urine. It is also useful for monitoring people ...

  8. Preliminary study on application of urine amino acids profiling for monitoring of renal tubular injury using GLC-MS.

    PubMed

    Kazubek-Zemke, Maja; Rybka, Jacek; Marchewka, Zofia; Rybka, Wojciech; Pawlik, Krzysztof; Długosz, Anna

    2014-11-14

    The early diagnosis of the nephrotoxic effect of xenobiotics and drugs is still an unsolved problem. Recent studies suggest a correlation between the nephrotoxic activity of xenobiotics and increased concentration of amino acids in urine. The presented study was focused on the application of GLC-MS method for amino acids profiling in human urine as a noninvasive method for monitoring of kidney condition and tubular injury level. The analytic method is based on the conversion of the amino acids present in the sample to tert-butyldimethylsilyl (TBDMS) derivatives and their analysis by gas-liquid chromatography-mass spectrometry (GLC-MS). The procedure of urine sample preparation for chromatographic analysis was optimized. The presence of 12 amino acids in most of the tested healthy human urine samples was detected. The significant differences in the levels of particular amino acids between patients with tubular injury and healthy controls were found, especially for lysine, valine, serine, alanine and leucine (on average 30.0, 7.5, 3.6, 2.9 and 0.5 fold respectively). We found that this approach based on GLC-MS detection can be used in nephrotoxicity studies for urine amino acids monitoring in exposure to xenobiotics and drugs.

  9. A novel way to monitor urine concentration: fluorescent concentration matrices.

    PubMed

    Dubayova, Katarina; Luckova, Iveta; Sabo, Jan; Karabinos, Anton

    2015-01-01

    The amount of water found in urine is important diagnostic information; nevertheless it is not yet directly determined. Indirectly, the water content in urine is expressed by its density (specific gravity). However, without the diuresis value it is not possible to determine whether the increase in density of urine is due to a decrease in water secretion or an increase in the concentration of secreted substances. This problem can be solved by the use of fluorescent concentration 3D-matrices which characterise urine concentration through the pφ (or -logφ) value of the first fluorescence centre. The urine fluorescent concentration 3D-matrix was created by the alignment of the synchronous spectra of the dilution series of urine starting from undiluted (pφ = 0) to 1000-fold diluted urine (pφ = 3). Using the fluorescence concentration 3D-matrix analysis of the urine samples from healthy individuals, a reference range was established for the value pφ, determining the normal, concentrated or diluted type of urine. The diagnostic potential of this approach was tested on urine samples from two patients with a chronic glomerulonephritis. The pφ value of the urine fluorescence concentration 3D-matrix analysis determines whether the urine sample falls within the normal, concentrated or diluted type of urine. This parameter can be directly utilised in sportsmen's hydration state monitoring, as well as in the diagnosis and treatment of serious diseases. An important advantage of this novel diagnostic approach is that a 12/24 h urine collection is not required, which predetermines it for use especially within paediatrics.

  10. A mobile bioassay laboratory for the assessment of internal doses based on in vivo and in vitro measurements.

    PubMed

    Dantas, B M; Lucena, E A; Dantas, A L A; Santos, M S; Julião, L Q C; Melo, D R; Sousa, W O; Fernandes, P C; Mesquita, S A

    2010-10-01

    Internal exposures may occur in nuclear power plants, radioisotope production, and in medicine and research laboratories. Such practices require quick response in case of accidents of a wide range of magnitudes. This work presents the design and calibration of a mobile laboratory for the assessment of accidents involving workers and the population as well as for routine monitoring. The system was set up in a truck with internal dimensions of 3.30 m × 1.60 m × 1.70 m and can identify photon emitters in the energy range of 100-3,000 keV in the whole body, organs, and in urine. A thyroid monitor consisting of a lead-collimated NaI(Tl)3" × 3" (7.62 × 7.62 cm) detector was calibrated with a neck-thyroid phantom developed at the IRD (Instituto de Radioproteção e Dosimetria). Whole body measurements were performed with a NaI(Tl)8" × 4" (20.32 × 10.16 cm) detector calibrated with a plastic-bottle phantom. Urine samples were measured with another NaI(Tl) 3" × 3" (7.62 × 7.62 cm) detector set up in a steel support. Standard solutions were provided by the National Laboratory for Metrology of Ionizing Radiation of the IRD. Urine measurements are based on a calibration of efficiency vs. energy for standard volumes. Detection limits were converted to minimum committed effective doses for the radionuclides of interest using standard biokinetic and dosimetric models in order to evaluate the applicability and limitations of the system. Sensitivities for high-energy activation and fission products show that the system is suitable for use in emergency and routine monitoring of individuals under risk of internal exposure by such radionuclides.

  11. Implementation of ICP-MS protocols for uranium urinary measurements in worker monitoring.

    PubMed

    Baglan, N; Cossonnet, C; Trompier, F; Ritt, J; Bérard, P

    1999-10-01

    The uranium concentration in human urine spiked with natural uranium and rat urine containing metabolized depleted uranium was determined by ICP-MS. The use of ICP-MS was investigated without any chemical treatment or after the different stages of a purification protocol currently carried out for routine monitoring. In the case of spiked urine, the measured uranium concentrations were consistent with those certified by an intercomparison network in radiotoxicological analysis (PROCORAD) and with those obtained by alpha spectrometry in the case of the urine containing metabolized uranium. The quantitative information which could be obtained in the different protocols investigated shows the extent to which ICP-MS provides greater flexibility for setting up appropriate monitoring approaches in radiation protection routines and accidental situations. This is due to the combination of high sensitivity and the accuracy with which traces of uranium in urine can be determined in a shorter time period. Moreover, it has been shown that ICP-MS measurement can be used to quantify the 235U isotope, which is useful for characterizing the nature of the uranium compound, but difficult to perform using alpha spectrometry.

  12. Adulterants in Urine Drug Testing.

    PubMed

    Fu, S

    Urine drug testing plays an important role in monitoring licit and illicit drug use for both medico-legal and clinical purposes. One of the major challenges of urine drug testing is adulteration, a practice involving manipulation of a urine specimen with chemical adulterants to produce a false negative test result. This problem is compounded by the number of easily obtained chemicals that can effectively adulterate a urine specimen. Common adulterants include some household chemicals such as hypochlorite bleach, laundry detergent, table salt, and toilet bowl cleaner and many commercial products such as UrinAid (glutaraldehyde), Stealth® (containing peroxidase and peroxide), Urine Luck (pyridinium chlorochromate, PCC), and Klear® (potassium nitrite) available through the Internet. These adulterants can invalidate a screening test result, a confirmatory test result, or both. To counteract urine adulteration, drug testing laboratories have developed a number of analytical methods to detect adulterants in a urine specimen. While these methods are useful in detecting urine adulteration when such activities are suspected, they do not reveal what types of drugs are being concealed. This is particularly the case when oxidizing urine adulterants are involved as these oxidants are capable of destroying drugs and their metabolites in urine, rendering the drug analytes undetectable by any testing technology. One promising approach to address this current limitation has been the use of unique oxidation products formed from reaction of drug analytes with oxidizing adulterants as markers for monitoring drug misuse and urine adulteration. This novel approach will ultimately improve the effectiveness of the current urine drug testing programs. © 2016 Elsevier Inc. All rights reserved.

  13. Advantages and Limitations of Androgen Receptor-Based Methods for Detecting Anabolic Androgenic Steroid Abuse as Performance Enhancing Drugs.

    PubMed

    Bailey, Kathy; Yazdi, Tahmineh; Masharani, Umesh; Tyrrell, Blake; Butch, Anthony; Schaufele, Fred

    2016-01-01

    Testosterone (T) and related androgens are performance enhancing drugs (PEDs) abused by some athletes to gain competitive advantage. To monitor unauthorized androgen abuse, doping control programs use mass spectrometry (MS) to detect androgens, synthetic anabolic-androgenic steroids (AASs) and their metabolites in an athlete's urine. AASs of unknown composition will not be detected by these procedures. Since AASs achieve their anabolic effects by activating the Androgen Receptor (AR), cell-based bioassays that measure the effect of a urine sample on AR activity are under investigation as complementary, pan-androgen detection methods. We evaluated an AR BioAssay as a monitor for androgen activity in urine pre-treated with glucuronidase, which releases T from the inactive T-glucuronide that predominates in urine. AR BioAssay activity levels were expressed as 'T-equivalent' concentrations by comparison to a T dose response curve. The T-equivalent concentrations of androgens in the urine of hypogonadal participants supplemented with T (in whom all androgenic activity should arise from T) were quantitatively identical to the T measurements conducted by MS at the UCLA Olympic Analytical Laboratory (0.96 ± 0.22). All 17 AASs studied were active in the AR BioAssay; other steroids were inactive. 12 metabolites of 10 commonly abused AASs, which are used for MS monitoring of AAS doping because of their prolonged presence in urine, had reduced or no AR BioAssay activity. Thus, the AR BioAssay can accurately and inexpensively monitor T, but its ability to monitor urinary AASs will be limited to a period immediately following doping in which the active AASs remain intact.

  14. Fully automated methods for the determination of hydrochlorothiazide in human plasma and urine.

    PubMed

    Hsieh, J Y; Lin, C; Matuszewski, B K; Dobrinska, M R

    1994-12-01

    LC assays utilizing fully automated sample preparation procedures on Zymark PyTechnology Robot and BenchMate Workstation for the quantification of hydrochlorothiazide (HCTZ) in human plasma and urine have been developed. After aliquoting plasma and urine samples, and adding internal standard (IS) manually, the robot executed buffer and organic solvent addition, liquid-liquid extraction, solvent evaporation and on-line LC injection steps for plasma samples, whereas, BenchMate performed buffer and organic solvent addition, liquid-liquid and solid-phase extractions, and on-line LC injection steps for urine samples. Chromatographic separations were carried out on Beckman Octyl Ultrasphere column using the mobile phase composed of 12% (v/v) acetonitrile and 88% of either an ion-pairing reagent (plasma) or 0.1% trifluoroacetic acid (urine). The eluent from the column was monitored with UV detector (271 nm). Peak heights for HCTZ and IS were automatically processed using a PE-Nelson ACCESS*CHROM laboratory automation system. The assays have been validated in the concentration range of 2-100 ng ml-1 in plasma and 0.1-20 micrograms ml-1 in urine. Both plasma and urine assays have the sensitivity and specificity necessary to determine plasma and urine concentrations of HCTZ from low dose (6.25/12.5 mg) administration of HCTZ to human subjects in the presence or absence of losartan.

  15. Monitoring Hydration Status Pre- and Post-Training among University Athletes Using Urine Color and Weight Loss Indicators

    ERIC Educational Resources Information Center

    Webb, Marquitta C.; Salandy, Sinead T.; Beckford, Safiya E.

    2016-01-01

    Objective: To investigate the hydration status pre- and post-training among university athletes using urine color and weight loss as indicators. Participants: Participants were 52 university athletes training for campus games in a developing country. Methods: Pre- and post-training urine specimens were compared with a standard urine color scale.…

  16. Urine assay for tenofovir to monitor adherence in real time to tenofovir disoproxil fumarate/emtricitabine as pre-exposure prophylaxis.

    PubMed

    Koenig, H C; Mounzer, K; Daughtridge, G W; Sloan, C E; Lalley-Chareczko, L; Moorthy, G S; Conyngham, S C; Zuppa, A F; Montaner, L J; Tebas, P

    2017-07-01

    Tenofovir disoproxil fumarate/emtricitabine (TDF/FTC) is approved for pre-exposure prophylaxis (PrEP) against HIV infection. Adherence is critical for the success of PrEP, but current adherence measurements are inadequate for real-time adherence monitoring. We developed and validated a urine assay to measure tenofovir (TFV) to objectively monitor adherence to PrEP. We developed a urine assay using high-performance liquid chromatography coupled to tandem mass spectrometry with high sensitivity/specificity for TFV that allowed us to determine TFV concentrations in log 10 categories between 0 and 10 000 ng/mL. We validated the assay in three cohorts: (1) HIV-positive subjects with undetectable viral loads on a TDF/FTC-based regimen, (2) healthy HIV-negative subjects who received a single dose of TDF/FTC, and (3) HIV-negative subjects receiving daily TDF/FTC as PrEP for 24 weeks. The urine assay detected TFV with greater sensitivity than plasma-based measures and with a window of measurements within 7 days of the last TDF/FTC dose. Based on the urine log-linear clearance after the last dose and its concordance with all detectable plasma levels, a urine TFV concentration > 1000 ng/mL was identified as highly predictive of the presence of TFV in plasma at > 10 ng/mL. The urine assay was able to distinguish high and low adherence patterns within the last 48 h (> 1000 ng/mL versus 10-1000 ng/mL), as well as nonadherence (< 10 ng/mL) extended over at least 1 week prior to measurement. We provide proof of concept that a semiquantitative urine assay measuring levels of TFV could be further developed into a point-of-care test and be a useful tool to monitor adherence to PrEP. © 2017 British HIV Association.

  17. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    PubMed

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  18. Elucidation of markers for monitoring morphine and its analogs in urine adulterated with pyridinium chlorochromate.

    PubMed

    Luong, Susan; Kuzhiumparambil, Unnikrishnan; Fu, Shanlin

    2015-09-17

    Currently, procedures that identify the drugs 'destroyed' in adulterated urine specimens are very limited. This study aimed to determine the effect of pyridinium chlorochromate (PCC) on routine opiate assays and identify reaction products formed. Results/methodology: Opiate-positive urines adulterated with PCC (20 and 100 mM) were analyzed using CEDIA ® immunoassay and GC-MS. Urine and water samples spiked with 6-monoacetylmorphine, morphine and its glucuronides (10 µg/ml) and PCC (0.02-100 mM) were monitored with LC-MS, and the products characterized. PCC significantly decreased the abundance of morphine, codeine and IS. Adulterated water and urine samples containing 6-monoacetylmorphine, morphine and morphine-3-glucuronide yielded morphinone-3-glucuronide, 7,14-dihydroxy-6-monoacetylmorphine, 7,8-diketo-6-monoacetylmorphine and 7,8-diketo-morphine (tentative assignment). Reaction pathways may be different in the two matrices.

  19. Bio-monitoring of mycotoxin exposure in Cameroon using a urinary multi-biomarker approach.

    PubMed

    Abia, Wilfred A; Warth, Benedikt; Sulyok, Michael; Krska, Rudolf; Tchana, Angele; Njobeh, Patrick B; Turner, Paul C; Kouanfack, Charles; Eyongetah, Mbu; Dutton, Mike; Moundipa, Paul F

    2013-12-01

    Bio-monitoring of human exposure to mycotoxin has mostly been limited to a few individually measured mycotoxin biomarkers. This study aimed to determine the frequency and level of exposure to multiple mycotoxins in human urine from Cameroonian adults. 175 Urine samples (83% from HIV-positive individuals) and food frequency questionnaire responses were collected from consenting Cameroonians, and analyzed for 15 mycotoxins and relevant metabolites using LC-ESI-MS/MS. In total, eleven analytes were detected individually or in combinations in 110/175 (63%) samples including the biomarkers aflatoxin M1, fumonisin B1, ochratoxin A and total deoxynivalenol. Additionally, important mycotoxins and metabolites thereof, such as fumonisin B2, nivalenol and zearalenone, were determined, some for the first time in urine following dietary exposures. Multi-mycotoxin contamination was common with one HIV-positive individual exposed to five mycotoxins, a severe case of co-exposure that has never been reported in adults before. For the first time in Africa or elsewhere, this study quantified eleven mycotoxin biomarkers and bio-measures in urine from adults. For several mycotoxins estimates indicate that the tolerable daily intake is being exceeded in this study population. Given that many mycotoxins adversely affect the immune system, future studies will examine whether combinations of mycotoxins negatively impact Cameroonian population particularly immune-suppressed individuals. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Simultaneous determination of nine neonicotinoids in human urine using isotope-dilution ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Quan; Wang, Ximing; Li, Zhe; Jin, Hangbiao; Lu, Zhengbiao; Yu, Chang; Huang, Yu-Fang; Zhao, Meirong

    2018-05-14

    Neonicotinoids (neonics), a class of systemic insecticides, have been frequently detected in pollen, vegetables, and fruits. Recently, an increasing concern has been aroused for human exposure to neonics. However, biological monitoring for quantifying body burden of neonics has rarely been reported. In this study, we developed an isotope-dilution ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) method to simultaneously quantify nine neonics, including acetamiprid (ACE), thiamethoxam (THIAM), imidacloprid (IMIP), clothianidin (CLO), flonicamid (FLO), thiacloprid (THIAC), dinotefuran (DIN), nitenpyram (NIT), and imidaclothiz (IMIT) in urine. The limits of quantification were 0.1 μg/L for ACE, FLO, DIN, NIT and IMIT, and 0.2 μg/L for THIAM, IMIP, CLO, and THIAC. The overall recoveries were 80.8-103%, 81.5-91.7% and 83.0-92.3% for QA/QC samples fortifying at 1, 25, and 100 μg/L levels, respectively. UPLC/MS/MS method was used to analyze urine samples obtained from 10 children in Hangzhou, China. The detection frequencies were 80% for ACE and IMIP, 70% for THIAM and CLO, 20% for DIN and IMIT and 10% for THIAC. FLO and NIT were not detected in those urine samples. The data provided here will be helpful for conducting biological monitoring of neonics exposure in the future. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Evaluation of the performance of Human Papillomavirus testing in paired urine and clinician-collected cervical samples among women aged over 30 years in Bhutan.

    PubMed

    Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2017-04-08

    Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.

  2. Detection of gluten immunogenic peptides in the urine of patients with coeliac disease reveals transgressions in the gluten-free diet and incomplete mucosal healing

    PubMed Central

    Moreno, María de Lourdes; Cebolla, Ángel; Muñoz-Suano, Alba; Carrillo-Carrion, Carolina; Comino, Isabel; Pizarro, Ángeles; León, Francisco; Rodríguez-Herrera, Alfonso; Sousa, Carolina

    2017-01-01

    Objective Gluten-free diet (GFD) is the only management for coeliac disease (CD). Available methods to assess GFD compliance are insufficiently sensitive to detect occasional dietary transgressions that may cause gut mucosal damage. We aimed to develop a method to determine gluten intake and monitor GFD compliance in patients with CD and to evaluate its correlation with mucosal damage. Design Urine samples of 76 healthy subjects and 58 patients with CD subjected to different gluten dietary conditions were collected. A lateral flow test (LFT) with the highly sensitive and specific G12 monoclonal antibody for the most dominant gluten immunogenic peptides (GIP) and a LFT reader were used to quantify GIP in solid-phase extracted urines. Results GIP were detectable in concentrated urines from healthy individuals previously subjected to GFD as early as 4–6 h after single gluten intake, and remained detectable for 1–2 days. The urine assay revealed infringement of the GFD in about 50% of the patients. Analysis of duodenal biopsies revealed that most of patients with CD (89%) with no villous atrophy had no detectable GIP in urine, while all patients with quantifiable GIP in urine showed incomplete intestinal mucosa recovery. Conclusion GIP are detected in urine after gluten consumption, enabling a new and non-invasive method to monitor GFD compliance and transgressions. The method was sensitive, specific and simple enough to be convenient for clinical monitoring of patients with CD as well as for basic and clinical research applications including drug development. Trial registration number NCT02344758. PMID:26608460

  3. Detection of gluten immunogenic peptides in the urine of patients with coeliac disease reveals transgressions in the gluten-free diet and incomplete mucosal healing.

    PubMed

    Moreno, María de Lourdes; Cebolla, Ángel; Muñoz-Suano, Alba; Carrillo-Carrion, Carolina; Comino, Isabel; Pizarro, Ángeles; León, Francisco; Rodríguez-Herrera, Alfonso; Sousa, Carolina

    2017-02-01

    Gluten-free diet (GFD) is the only management for coeliac disease (CD). Available methods to assess GFD compliance are insufficiently sensitive to detect occasional dietary transgressions that may cause gut mucosal damage. We aimed to develop a method to determine gluten intake and monitor GFD compliance in patients with CD and to evaluate its correlation with mucosal damage. Urine samples of 76 healthy subjects and 58 patients with CD subjected to different gluten dietary conditions were collected. A lateral flow test (LFT) with the highly sensitive and specific G12 monoclonal antibody for the most dominant gluten immunogenic peptides (GIP) and a LFT reader were used to quantify GIP in solid-phase extracted urines. GIP were detectable in concentrated urines from healthy individuals previously subjected to GFD as early as 4-6 h after single gluten intake, and remained detectable for 1-2 days. The urine assay revealed infringement of the GFD in about 50% of the patients. Analysis of duodenal biopsies revealed that most of patients with CD (89%) with no villous atrophy had no detectable GIP in urine, while all patients with quantifiable GIP in urine showed incomplete intestinal mucosa recovery. GIP are detected in urine after gluten consumption, enabling a new and non-invasive method to monitor GFD compliance and transgressions. The method was sensitive, specific and simple enough to be convenient for clinical monitoring of patients with CD as well as for basic and clinical research applications including drug development. NCT02344758. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Mirtazapine to Reduce Methamphetamine Use

    PubMed Central

    Colfax, Grant N.; Santos, Glenn-Milo; Das, Moupali; Santos, Deirdre McDermott; Matheson, Tim; Gasper, James; Shoptaw, Steve; Vittinghoff, Eric

    2012-01-01

    Context No approved pharmacologic treatments for methamphetamine dependence exist. Methamphetamine use is associated with high morbidity and is a major cofactor in the human immunodeficiency virus epidemic among men who have sex with men (MSM). Objective To determine whether mirtazapine would reduce methamphetamine use among MSM who are actively using methamphetamine. Design Double-blind, randomized, controlled, 12-week trial of mirtazapine vs placebo conducted from September 5, 2007, to March 4, 2010. Setting San Francisco Department of Public Health. Participants Participants were actively using, methamphetamine-dependent, sexually active MSM seen weekly for urine sample collection and substance use counseling. Interventions Random assignment to daily oral mirtazapine (30 mg) or placebo; both arms included 30-minute weekly substance use counseling. Main Outcome Measures The primary study outcome was reduction in methamphetamine-positive urine test results. Secondary outcomes were study medication adherence (by self-report and medication event monitoring systems) and sexual risk behavior. Results Sixty MSM were randomized, 85% of follow-up visits were completed, and 56 participants (93%) completed the final visit. In the primary intent-to-treat analysis, participants assigned to the mirtazapine group had fewer methamphetamine-positive urine test results compared with participants assigned to the placebo group (relative risk, 0.57; 95% CI, 0.35–0.93, P = .02). Urine positivity decreased from 67% (20 of 30 participants) to 63% (17 of 27) in the placebo arm and from 73% (22 of 30) to 44% (12 of 27) in the mirtazapine arm. The number needed to treat to achieve a negative weekly urine test result was 3.1. Adherence was 48.5% by medication event monitoring systems and 74.7% by self-report; adherence measures were not significantly different between arms (medication event monitoring systems, P = .82; self-report, P = .92). Most sexual risk behaviors decreased significantly more among participants taking mirtazapine compared with those taking placebo (number of male partners with whom methamphetamine was used, P = .009; number of male partners, P = .04; episodes of anal sex with serodiscordant partners, P = .003; episodes of unprotected anal sex with serodiscordant partners, P = .003; episodes of insertive anal sex with serodiscordant partners, P = .001). There were no serious adverse events related to study drug or significant differences in adverse events by arm (P ≥ .99). Conclusion The addition of mirtazapine to substance use counseling decreased methamphetamine use among active users and was associated with decreases in sexual risk despite low to moderate medication adherence. PMID:22065532

  5. Urine 1,6-Hexamethylene Diamine (HDA) Levels Among Workers Exposed to 1,6-Hexamethylene Diisocyanate (HDI)

    PubMed Central

    Gaines, Linda G. T.; Fent, Kenneth W.; Flack, Sheila L.; Thomasen, Jennifer M.; Ball, Louise M.; Richardson, David B.; Ding, Kai; Whittaker, Stephen G.; Nylander-french, Leena A.

    2010-01-01

    Urinary 1,6-hexamethylene diamine (HDA) may serve as a biomarker for systemic exposure to 1,6-hexamethylene diisocyanate (HDI) in occupationally exposed populations. However, the quantitative relationships between dermal and inhalation exposure to HDI and urine HDA levels have not been established. We measured acid-hydrolyzed urine HDA levels along with dermal and breathing-zone levels of HDI in 48 automotive spray painters. These measurements were conducted over the course of an entire workday for up to three separate workdays that were spaced approximately 1 month apart. One urine sample was collected before the start of work with HDI-containing paints and subsequent samples were collected during the workday. HDA levels varied throughout the day and ranged from nondetectable to 65.9 μg l−1 with a geometric mean and geometric standard deviation of 0.10 μg l−1 ± 6.68. Dermal exposure and inhalation exposure levels, adjusted for the type of respirator worn, were both significant predictors of urine HDA levels in the linear mixed models. Creatinine was a significant covariate when used as an independent variable along with dermal and respirator-adjusted inhalation exposure. Consequently, exposure assessment models must account for the water content of a urine sample. These findings indicate that HDA exhibits a biphasic elimination pattern, with a half-life of 2.9 h for the fast elimination phase. Our results also indicate that urine HDA level is significantly associated with systemic HDI exposure through both the skin and the lungs. We conclude that urinary HDA may be used as a biomarker of exposure to HDI, but biological monitoring should be tailored to reliably capture the intermittent exposure pattern typical in this industry. PMID:20530123

  6. Urine 1,6-hexamethylene diamine (HDA) levels among workers exposed to 1,6-hexamethylene diisocyanate (HDI).

    PubMed

    Gaines, Linda G T; Fent, Kenneth W; Flack, Sheila L; Thomasen, Jennifer M; Ball, Louise M; Richardson, David B; Ding, Kai; Whittaker, Stephen G; Nylander-French, Leena A

    2010-08-01

    Urinary 1,6-hexamethylene diamine (HDA) may serve as a biomarker for systemic exposure to 1,6-hexamethylene diisocyanate (HDI) in occupationally exposed populations. However, the quantitative relationships between dermal and inhalation exposure to HDI and urine HDA levels have not been established. We measured acid-hydrolyzed urine HDA levels along with dermal and breathing-zone levels of HDI in 48 automotive spray painters. These measurements were conducted over the course of an entire workday for up to three separate workdays that were spaced approximately 1 month apart. One urine sample was collected before the start of work with HDI-containing paints and subsequent samples were collected during the workday. HDA levels varied throughout the day and ranged from nondetectable to 65.9 microg l(-1) with a geometric mean and geometric standard deviation of 0.10 microg l(-1) +/- 6.68. Dermal exposure and inhalation exposure levels, adjusted for the type of respirator worn, were both significant predictors of urine HDA levels in the linear mixed models. Creatinine was a significant covariate when used as an independent variable along with dermal and respirator-adjusted inhalation exposure. Consequently, exposure assessment models must account for the water content of a urine sample. These findings indicate that HDA exhibits a biphasic elimination pattern, with a half-life of 2.9 h for the fast elimination phase. Our results also indicate that urine HDA level is significantly associated with systemic HDI exposure through both the skin and the lungs. We conclude that urinary HDA may be used as a biomarker of exposure to HDI, but biological monitoring should be tailored to reliably capture the intermittent exposure pattern typical in this industry.

  7. A Low Cost Device for Monitoring the Urine Output of Critical Care Patients

    PubMed Central

    Otero, Abraham; Palacios, Francisco; Akinfiev, Teodor; Apalkov, Andrey

    2010-01-01

    In critical care units most of the patients’ physiological parameters are sensed by commercial monitoring devices. These devices can also supervise whether the values of the parameters lie within a pre-established range set by the clinician. The automation of the sensing and supervision tasks has discharged the healthcare staff of a considerable workload and avoids human errors, which are common in repetitive and monotonous tasks. Urine output is very likely the most relevant physiological parameter that has yet to be sensed or supervised automatically. This paper presents a low cost patent-pending device capable of sensing and supervising urine output. The device uses reed switches activated by a magnetic float in order to measure the amount of urine collected in two containers which are arranged in cascade. When either of the containers fills, it is emptied automatically using a siphon mechanism and urine begins to collect again. An electronic unit sends the state of the reed switches via Bluetooth to a PC that calculates the urine output from this information and supervises the achievement of therapeutic goals. PMID:22163495

  8. A low cost device for monitoring the urine output of critical care patients.

    PubMed

    Otero, Abraham; Palacios, Francisco; Akinfiev, Teodor; Apalkov, Andrey

    2010-01-01

    In critical care units most of the patients' physiological parameters are sensed by commercial monitoring devices. These devices can also supervise whether the values of the parameters lie within a pre-established range set by the clinician. The automation of the sensing and supervision tasks has discharged the healthcare staff of a considerable workload and avoids human errors, which are common in repetitive and monotonous tasks. Urine output is very likely the most relevant physiological parameter that has yet to be sensed or supervised automatically. This paper presents a low cost patent-pending device capable of sensing and supervising urine output. The device uses reed switches activated by a magnetic float in order to measure the amount of urine collected in two containers which are arranged in cascade. When either of the containers fills, it is emptied automatically using a siphon mechanism and urine begins to collect again. An electronic unit sends the state of the reed switches via Bluetooth to a PC that calculates the urine output from this information and supervises the achievement of therapeutic goals.

  9. Electronic monitoring of treatment adherence and validation of alternative adherence measures in tuberculosis patients: a pilot study.

    PubMed

    van den Boogaard, Jossy; Lyimo, Ramsey A; Boeree, Martin J; Kibiki, Gibson S; Aarnoutse, Rob E

    2011-09-01

    To assess adherence to community-based directly observed treatment (DOT) among Tanzanian tuberculosis patients using the Medication Event Monitoring System (MEMS) and to validate alternative adherence measures for resource-limited settings using MEMS as a gold standard. This was a longitudinal pilot study of 50 patients recruited consecutively from one rural hospital, one urban hospital and two urban health centres. Treatment adherence was monitored with MEMS and the validity of the following adherence measures was assessed: isoniazid urine test, urine colour test, Morisky scale, Brief Medication Questionnaire, adapted AIDS Clinical Trials Group (ACTG) adherence questionnaire, pill counts and medication refill visits. The mean adherence rate in the study population was 96.3% (standard deviation, SD: 7.7). Adherence was less than 100% in 70% of the patients, less than 95% in 21% of them, and less than 80% in 2%. The ACTG adherence questionnaire and urine colour test had the highest sensitivities but lowest specificities. The Morisky scale and refill visits had the highest specificities but lowest sensitivities. Pill counts and refill visits combined, used in routine practice, yielded moderate sensitivity and specificity, but sensitivity improved when the ACTG adherence questionnaire was added. Patients on community-based DOT showed good adherence in this study. The combination of pill counts, refill visits and the ACTG adherence questionnaire could be used to monitor adherence in settings where MEMS is not affordable. The findings with regard to adherence and to the validity of simple adherence measures should be confirmed in larger populations with wider variability in adherence rates.

  10. Fructo-Oligosaccharide (DFA III) Feed Supplementation for Mitigation of Mycotoxin Exposure in Cattle-Clinical Evaluation by a Urinary Zearalenone Monitoring System.

    PubMed

    Toda, Katsuki; Uno, Seiichi; Kokushi, Emiko; Shiiba, Ayaka; Hasunuma, Hiroshi; Matsumoto, Daisaku; Ohtani, Masayuki; Yamato, Osamu; Shinya, Urara; Wijayagunawardane, Missaka; Fink-Gremmels, Johanna; Taniguchi, Masayasu; Takagi, Mitsuhiro

    2018-06-01

    The potential effect of difructose anhydride III (DFA III) supplementation in cattle feed was evaluated using a previously developed urinary-zearalenone (ZEN) monitoring system. Japanese Black cattle from two beef herds aged 9⁻10 months were used. DFA III was supplemented for two weeks. ZEN concentrations in feed were similar in both herds (0.27 and 0.22 mg/kg in roughage and concentrates, respectively), and below the maximum allowance in Japan. ZEN, α-zearalenol (α-ZOL), and β-ZOL concentrations in urine were measured using LC/MS/MS the day before DFA III administration, 9 and 14 days thereafter, and 9 days after supplementation ceased. Significant differences in ZEN, α-ZOL, β-ZOL, and total ZEN were recorded on different sampling dates. The concentration of inorganic phosphate in DFA III-supplemented animals was significantly higher than in controls on day 23 (8.4 vs. 7.7 mg/dL), suggesting a possible role of DFA III in tight junction of intestinal epithelial cells. This is the first evidence that DFA III reduces mycotoxin levels reaching the systemic circulation and excreted in urine. This preventive effect may involve an improved tight-junction-dependent intestinal barrier function. Additionally, our practical approach confirmed that monitoring of urinary mycotoxin is useful for evaluating the effects of dietary supplements to prevent mycotoxin adsorption.

  11. Clinical evaluation and use of urine screening for drug abuse.

    PubMed Central

    Saxon, A J; Calsyn, D A; Haver, V M; Delaney, C J

    1988-01-01

    Urine drug screening is indicated to evaluate patients who show mental status or behavioral changes and to monitor the abstinence of drug abusers. The appropriate timing for collecting urine specimens may vary depending on the suspected drug of abuse and on laboratory factors. Laboratories use a variety of techniques to do urine screens, and these must be understood by clinicians ordering the screens to interpret results correctly. In treating drug-abusing patients, clinicians must apply structured reinforcement in conjunction with urine screen results to aid patients in achieving abstinence. PMID:3176489

  12. Simple Quantification of Pentosidine in Human Urine and Plasma by High-Performance Liquid Chromatography

    PubMed Central

    Lee, Ji Sang; Chung, Yoon-Sok; Chang, Sun Young

    2017-01-01

    Pentosidine is an advanced glycation end-product (AGE) and fluorescent cross-link compound. A simple high-performance liquid chromatographic (HPLC) method was developed for the detection and quantification of pentosidine in human urine and plasma. The mobile phase used a gradient system to improve separation of pentosidine from endogenous peaks, and chromatograms were monitored by fluorescent detector set at excitation and emission wavelengths of 328 and 378 nm, respectively. The retention time for pentosidine was 24.3 min and the lower limits of quantification (LLOQ) in human urine and plasma were 1 nM. The intraday assay precisions (coefficients of variation) were generally low and found to be in the range of 5.19–7.49% and 4.96–8.78% for human urine and plasma, respectively. The corresponding values of the interday assay precisions were 9.45% and 4.27%. Accuracies (relative errors) ranged from 87.9% to 115%. Pentosidine was stable in a range of pH solutions, human urine, and plasma. In summary, this HPLC method can be applied in future preclinical and clinical evaluation of pentosidine in the diabetic patients. PMID:29181026

  13. Urinary Tract Effects After Multifocal Nonthermal Irreversible Electroporation of the Kidney: Acute and Chronic Monitoring by Magnetic Resonance Imaging, Intravenous Urography and Urinary Cytology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wendler, Johann Jakob, E-mail: johann.wendler@med.ovgu.de; Pech, Maciej; Porsch, Markus

    2012-08-15

    Purpose: The nonthermal irreversible electroporation (NTIRE) is a novel potential ablation modality for renal masses. The aim of this study was the first evaluation of NTIRE's effects on the renal urine-collecting system using intravenous urography (IVU) and urinary cytology in addition to histology and magnetic resonance imaging (MRI). Methods: Eight percutaneous NTIRE ablations of the renal parenchyma, including the calyxes or pelvis, were performed in three male swine. MRI, IVU, histology, and urinary cytology follow-ups were performed within the first 28 days after treatment. Results: MRI and histological analysis demonstrated a localized necrosis 7 days and a localized scarification ofmore » the renal parenchyma with complete destruction 28 days after NTIRE. The urine-collecting system was preserved and showed urothelial regeneration. IVU and MRI showed an unaltered normal morphology of the renal calyxes, pelvis, and ureter. A new urinary cytology phenomenon featured a temporary degeneration by individual vacuolization of detached transitional epithelium cells within the first 3 days after NTIRE. Conclusions: This first urographical, urine-cytological, and MRI evaluation after porcine kidney NTIRE shows multifocal parenchyma destruction while protecting the involved urine-collecting system with regenerated urothelial tissue. NTIRE could be used as a targeted ablation method of centrally located renal masses.« less

  14. 21 CFR 866.6010 - Tumor-associated antigen immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease. (b) Classification.... 866.6010 Section 866.6010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  15. 21 CFR 866.6010 - Tumor-associated antigen immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease. (b) Classification.... 866.6010 Section 866.6010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  16. 21 CFR 866.6010 - Tumor-associated antigen immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease. (b) Classification.... 866.6010 Section 866.6010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  17. 21 CFR 866.6010 - Tumor-associated antigen immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease. (b) Classification.... 866.6010 Section 866.6010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  18. Smartphone-based analysis of biochemical tests for health monitoring support at home.

    PubMed

    Velikova, Marina; Smeets, Ruben L; van Scheltinga, Josien Terwisscha; Lucas, Peter J F; Spaanderman, Marc

    2014-09-01

    In the context of home-based healthcare monitoring systems, it is desirable that the results obtained from biochemical tests - tests of various body fluids such as blood and urine - are objective and automatically generated to reduce the number of man-made errors. The authors present the StripTest reader - an innovative smartphone-based interpreter of biochemical tests based on paper-based strip colour using image processing techniques. The working principles of the reader include image acquisition of the colour strip pads using the camera phone, analysing the images within the phone and comparing them with reference colours provided by the manufacturer to obtain the test result. The detection of kidney damage was used as a scenario to illustrate the application of, and test, the StripTest reader. An extensive evaluation using laboratory and human urine samples demonstrates the reader's accuracy and precision of detection, indicating the successful development of a cheap, mobile and smart reader for home-monitoring of kidney functioning, which can facilitate the early detection of health problems and a timely treatment intervention.

  19. The use of isoniazid as a marker to monitor the self-administration of medicaments.

    PubMed Central

    Stark, J E; Ellard, G A; Gammon, P T; Fox, W

    1975-01-01

    1. Isoniazid was used as a marker to monitor the regularity of drug self-administration in a trial of chemoprophylaxis against natural influenza infection. Two hundred and sixty-two volunteers were treated for five weeks with a synthetic isoquinoline compound (U.K. 2371) or a matching placebo. 2. Five marker tablets containing isoniazid (150 mg) were incorporated into each regimen and their ingestion monitored by testing for acetylisoniazid in the urine. 3. Positive evidence of marker tablet consumption was obtained on 75% of the occasions on which urine samples were requested. The results obtained among the volunteers from each treatment group who returned urine specimens as requested (92%) indicated that they had swallowed at least 81% of their prescribed tablets. 4. The findings of the study suggest that when used in this way isoniazid is a very suitable compound for use on a few occasions for monitoring the self-administration of drugs in clinical trials. PMID:788733

  20. Enzymatic Activity of Candida spp. from Oral Cavity and Urine in Children with Nephrotic Syndrome.

    PubMed

    Olczak-Kowalczyk, Dorota; Roszkowska-Blaim, Maria; Dąbkowska, Maria; Swoboda-Kopeć, Ewa; Gozdowski, Dariusz; Mizerska-Wasiak, Małgorzata; Demkow, Urszula; Pańczyk-Tomaszewska, Małgorzata

    2017-01-01

    Oral colonization with Candida spp. is not synonymous with a systemic active infection. The aim of the study was to evaluate enzymatic activity of Candida strains isolated from the oral cavity in patients with nephrotic syndrome (NS) and to compare it with the activity determined in urine. We studied 32 children with NS and 26 control healthy children. Children with NS were treated with glucocorticosteroids, cyclosporin A, mycophenolate mofetil or azathioprine. In all children, API-ZYM enzymatic tests were performed to evaluate hydrolytic enzymes of Candida isolated from the oral cavity and in urine. Candida spp. were isolated from the oral cavity in 11 patients with NS (34.4%), all receiving immunosuppressive treatment. All strains produced valine arylamidase, 9 alpha-glucosidase (E16), and 9 N-acetyl-beta-glucosaminidase (E18). A positive correlation between the presence of Candida in the oral cavity and E16 and E18 enzymatic activity in both oral cavity and urine was found. A dose of cyclosporin A had an effect on the enzymatic activity (p < 0.05). We conclude that immunosuppressive treatment of NS in children may predispose to systemic Candida invasion. The results of this study suggest that oral candida infection should be monitored in children with nephrotic syndrome, particularly those treated with immunosuppressive agents.

  1. Antipsychotic drug poisoning monitoring of clozapine in urine by using coffee ring effect based surface-enhanced Raman spectroscopy.

    PubMed

    Zhu, Qingxia; Yu, Xiaoyan; Wu, Zebing; Lu, Feng; Yuan, Yongfang

    2018-07-19

    Antipsychotics are the drugs most often involved in drug poisoning cases, and therefore, therapeutic drug monitoring (TDM) is necessary for safe and effective medication administration of these drugs. In this study, a coffee ring effect-based surface-enhanced Raman spectroscopy (CRE-SERS) method was developed and successfully used to monitor antipsychotic poisoning by using urine samples for the first time. The established method exhibited excellent SERS performance since more hot spots were obtained in the "coffee ring". Using the optimized CRE-SERS method, the sensitivity was improved one order more than that of the conventional method with reasonable reproducibility. The antipsychotic drug clozapine (CLO) spiked into urine samples at 0.5-50 μg mL -1 was quantitatively detected, at concentrations above the thresholds for toxicity. The CRE-SERS method allowed CLO and its metabolites to be ultimately distinguished from real poisoning urine samples. The coffee-ring effect would provide more opportunities for practical applications of the SERS-based method. The frequent occurrence of drug poisoning may have created a new area for the application of the CRE-SERS method. It is anticipated that the developed method will also have great potential for other drug poisoning monitoring. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Burn Resuscitation Decision Support System (BRDSS)

    DTIC Science & Technology

    2014-11-01

    agreement was to package the software into a mobile device (the BRDSS-M, trade name Burn Navigator™) with substantial input from caregivers at the USAISR...combat casualties with >30% TBSA burns developed abdominal compartment syndrome (ACS) and perished.2 Between January 2006 and June 2007, after the...or even an open-loop system, could integrate the urine output monitor and infusion pump and free up the caregiver from manual data entry tasks to

  3. Development of Personalized Urination Recognition Technology Using Smart Bands.

    PubMed

    Eun, Sung-Jong; Whangbo, Taeg-Keun; Park, Dong Kyun; Kim, Khae-Hawn

    2017-04-01

    This study collected and analyzed activity data sensed through smart bands worn by patients in order to resolve the clinical issues posed by using voiding charts. By developing a smart band-based algorithm for recognizing urination activity in patients, this study aimed to explore the feasibility of urination monitoring systems. This study aimed to develop an algorithm that recognizes urination based on a patient's posture and changes in posture. Motion data was obtained from a smart band on the arm. An algorithm that recognizes the 3 stages of urination (forward movement, urination, backward movement) was developed based on data collected from a 3-axis accelerometer and from tilt angle data. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the absolute value of the signals was calculated and then compared with the set threshold value to determine the occurrence of vibration signals. In feature extraction, the most essential information describing each pattern was identified after analyzing the characteristics of the data. The results of the feature extraction process were sorted using a classifier to detect urination. An experiment was carried out to assess the performance of the recognition technology proposed in this study. The final accuracy of the algorithm was calculated based on clinical guidelines for urologists. The experiment showed a high average accuracy of 90.4%, proving the robustness of the proposed algorithm. The proposed urination recognition technology draws on acceleration data and tilt angle data collected via a smart band; these data were then analyzed using a classifier after comparative analyses with standardized feature patterns.

  4. Dermal uptake and excretion of 4,4'-methylenedianiline during rotor blade production in helicopter industry--an intervention study.

    PubMed

    Weiss, Tobias; Schuster, Hubert; Müller, Johannes; Schaller, Karl-Heinz; Drexler, Hans; Angerer, Jürgen; Käfferlein, Heiko U

    2011-10-01

    Workers using composite materials by fibre reinforced laminate technology are exposed to 4,4'-methylenedianiline (MDA), a liver toxicant and suspected human carcinogen, during the production of rotor blades in helicopter industry. The aim of the study presented here was to assess the internal dose of MDA and the suitability of various personal protection measures at the workplace. Ambient monitoring and biological monitoring was carried out by analysing MDA in air and urine samples in seven workers of a highly specialized workplace (rotor blade production). Three different concepts of personal protection measures were applied to study the route of uptake and to evaluate strategies in decreasing workplace exposure. In addition, elimination kinetics of MDA was studied in three workers who were exposed to MDA on three consecutive working days. Ambient monitoring consistently provided air levels at or below the limit of quantification of 0.1 μg m(-3). Nevertheless, MDA was detected in 89% of all post-shift urine samples and median concentration was 4.2 μg l(-1). MDA in urine were >20 times higher than expected on data from ambient monitoring alone. A significant decrease in exposure could be achieved when workers have worn MDA-protective overalls in combination with MDA-protective gloves and a splash protection shield (from 9.8 μg l(-1) down to 3.7 μg l(-1)). The results show that MDA is taken up primarily via the skin at the workplaces under study. The excretion of MDA in urine was observed to be delayed after dermal exposure. Exposure assessment of MDA should be carried out by biological monitoring rather than ambient monitoring. For this purpose, urine samples midweek or at the end of the week should be used based on the observed delay in the excretion of MDA after dermal absorption. Uptake of MDA via the skin could not be completely avoided even if state-of-the-art personal protection measures were applied.

  5. The potential of at-home prediction of the formation of urolithiasis by simple multi-frequency electrical conductivity of the urine and the comparison of its performance with urine ion-related indices, color and specific gravity.

    PubMed

    Silverio, Angelito A; Chung, Wen-Yaw; Cheng, Cheanyeh; Wang, Hai-Lung; Kung, Chien-Min; Chen, Jun; Tsai, Vincent F S

    2016-04-01

    It is important to control daily diet, water intake and life style as well as monitor the quality of urine for urolithiasis prevention. For decades, many ion-related indices have been developed for predicting the formation of urinary stones or urolithiasis, such as EQUILs, relative supersaturation (RSS), Tiselius indices (TI), Robertson risk factor algorithms (RRFA) and more recently, the Bonn risk index. However, they mostly demand robust laboratory analysis, are work-intensive, and even require complex computational programs to get the concentration patterns of several urine analytes. A simple and fast platform for measuring multi-frequency electrical conductivity (MFEC) of morning spot urine (random urine) to predict the onset of urolithiasis was implemented in this study. The performance thereof was compared to ion-related indices, urine color and specific gravity. The concentrations of relevant ions, color, specific gravity (SG) and MFEC (MFEC tested at 1, 10, 100, 5001 KHz and 1 MHz) of 80 random urine samples were examined after collection. Then, the urine samples were stored at 4 °C for 24 h to determine whether sedimentation would occur or not. Ion-activity product index of calcium oxalate (AP(CaOx) EQ2) was calculated. The correlation between AP(CaOx) EQ2, urine color, SG and MFEC were analyzed. AP(CaOx) EQ2, urine color and MFEC (at 5 frequencies) all demonstrated good prediction (p = 0.01, 0.01, 0.01, respectively) for stone formation. The positive correlation between AP(CaOx) EQ2 and MFEC is also significant (p = 0.01). MFEC provides a good metric for predicting the onset of urolithiasis, which is comparable to conventional ion-related indices and urine color. This technology can be implemented with much ease for objectively monitoring the quality of urine at points-of-care or at home.

  6. An Initial Evaluation of a Comprehensive Continuing Care Intervention for Clients with Substance Use Disorders: My First Year of Recovery (MyFYR).

    PubMed

    McKay, James R; Knepper, Cheryl; Deneke, Erin; O'Reilly, Christopher; DuPont, Robert L

    2016-08-01

    Physician health programs (PHPs) generate high rates of sustained abstinence in addicted physicians, through a combination of formal treatment, self-help involvement, regular monitoring via random urine toxicology tests, and powerful incentives generated by the threat of losing one's medical license. Recently, Caron Treatment Centers developed a new continuing care intervention, "My First Year of Recovery" (MyFYR), which is modeled after PHPs but provides extended recovery support to a broader segment of those with substance use disorders. This paper presents initial outcome data from MyFYR. MyFYR features frequent outcomes monitoring via urine toxicology tests, and also includes a web-based social platform to coordinate efforts of recovery coaches, family members, and others (e.g., employers, probation officers). Participants were the first 198 clients who enrolled in MyFYR after participating in residential treatment at Caron. Substance use outcomes were determined by a combination of urine toxicology tests, client self-report, and information from family members obtained during a 12-month period following entry into MyFYR. Clients in MyFYR provided 70% of scheduled urine samples, for an average of 16.4 urine samples per client. Only 4.1% of the samples tested positive for alcohol or any drug. As determined by urine toxicology and client and family reports, 54% of the participants had some use of alcohol or drugs during the follow-up. Of these relapsed clients, 70.1% were retained or re-engaged in MyFYR, and of these, half were able to re-establish abstinence of two months duration or more, as documented by urine toxicology. These initial results are extremely promising, as they document high rates of sustained participation in urine drug test monitoring and positive outcome in clients not under the threat of losing a professional license or incarceration. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Monitoring of exposure to methylpentanes by diffusive sampling and urine analysis for alcoholic metabolites.

    PubMed Central

    Kawai, T; Mizunuma, K; Yasugi, T; Horiguchi, S; Iguchi, H; Mutti, A; Ghittori, S; Ikeda, M

    1995-01-01

    OBJECTIVES--To investigate the possibilities of personal ambient monitoring and biological monitoring for methylpentane isomers. METHODS--The performance of activated carbon cloth to absorb 2- and 3-methylpentane was studied by experimental vapour exposure followed by solvent extraction and gas chromatography (GC). Urine from workers and rats exposed to 2- and 3-methylpentane was analysed by GC with or without acid or enzymatic hydrolysis. RESULTS--Carbon cloth absorbed 2- and 3-methylpentane linearly to exposures up to eight hours and to 400 ppm, and was sensitive enough to detect a 15 minute peak of exposure. The two isomers were clearly separated from hexane on a DB-1 column. For analysis of the urine, enzymatic hydrolysis was superior to acid hydrolysis. Exposure of rats to methylpentane vapours showed that 2-methyl-2-pentanol and 3-methyl-2-pentanol were excreted in urine in proportion to the dose of 2-methylpentane and 3-methylpentane, respectively. 2-Methyl derivatives of 1-, 3-, and 4-propanol, 2-methylpentane-2,4-diol, and 3-methyl-2-pentanol were minor metabolites. Analysis of urine from the exposed workers showed that 2-methyl- and 3-methyl-2-pentanol are leading urinary metabolites after exposure to the corresponding methylpentane. CONCLUSIONS--Diffusive sampling is applicable to monitor 2- and 3-methylpentane vapours as is the case for hexane vapour. 2-Methyl-2-pentanol and 3-methyl-2-pentanol will be markers of occupational exposure to 2-methylpentane and 3-methylpentane, respectively. Also, 2-methylpentane-2,4-diol might be a marker of exposure to 2-methylpentane. PMID:8535496

  8. Metabolism and bioactivation of the tricyclic antidepressant amitriptyline in human liver microsomes and human urine.

    PubMed

    Zhou, Xin; Chen, Chang; Zhang, Fangrong; Zhang, Yang; Feng, Yuling; Ouyang, Hui; Xu, Yong; Jiang, Hongliang

    2016-07-01

    Amitriptyline is a widely used tricyclic antidepressant, but the metabolic studies were conducted almost 20 years ago using high-performance liquid chromatography coupled with ultraviolet detector or radiolabeled methods. First, multiple ion monitoring (MIM)- enhanced product ion (EPI) scan was used to obtain the diagnostic ions or neutral losses in human liver microsome incubations with amitriptyline. Subsequently, predicted multiple reaction monitoring (MRM)-EPI scan was used to identify the metabolites in human urine with the diagnostic ions or neutral losses. Finally, product ion filtering and neutral loss filtering were used as the data mining tools to screen metabolites. Consequently, a total of 28 metabolites were identified in human urine after an oral administration using LC-MS/MS. An integrated workflow using LC-MS/MS was developed to comprehensively profile the metabolites of amitriptyline in human urine, in which five N-acetyl-l-cysteine conjugates were characterized as tentative biomarkers for idiosyncratic toxicity.

  9. Assessment of genotoxic exposure in Swedish coke-oven work by different methods of biological monitoring.

    PubMed

    Reuterwall, C; Aringer, L; Elinder, C G; Rannug, A; Levin, J O; Juringe, L; Onfelt, A

    1991-04-01

    This study evaluated the results of several biological methods used simultaneously to monitor coke-oven work. Blood samples from 44 male coke-oven workers and 48 male referents, matched for age and smoking/snuff consumption, were examined for cytogenetic damage in lymphocytes. Urinary thioether excretion was determined for 62, and urine mutagenicity for 31, of the subjects, who followed a standardized diet during the urine sampling. Exposure to polycyclic aromatic hydrocarbons varied with work task, the ambient air levels of benzo[a]pyrene sometimes exceeding 5 micrograms/m3. Cytogenetic damage, urine mutagenicity, and thioether excretion did not differ between the groups. The smokers, however, had significantly higher sister chromatid exchange frequencies, urine mutagenicity, and thioether excretion than the nonsmokers. The absence of biological indications of genotoxic exposure was unexpected and indicates that the studied methods are not adequate to assess the carcinogenic risks of Swedish coke-oven workers.

  10. Self monitoring of glucose by people with diabetes: evidence based practice.

    PubMed Central

    Gallichan, M.

    1997-01-01

    The inappropriate use of self monitoring of glucose is wasteful of NHS resources and can cause psychological harm. Although a few patients find that self monitoring enables them to understand and take control of their diabetes, many people with diabetes are performing inaccurate or unnecessary tests. There is no convincing evidence that self monitoring improves glycaemic control, nor that blood testing is necessarily better than urine testing. It may be appropriate for some patients not to monitor their own glucose but to rely instead on regular laboratory estimations of glycaemic control. Glucose self monitoring should be performed only when it serves an identified purpose. It is widely assumed that glucose self monitoring, preferably of blood glucose concentrations, is desirable or even essential for everyone with diabetes. It is common for patients who have previously tested their urine, or have done no glucose monitoring at home, to be taught to measure their blood glucose when they are admitted to hospital. In the community too, patients are often encouraged to monitor their blood glucose, and newly diagnosed patients of all ages are usually taught to measure their blood glucose concentrations. Self monitoring can sometimes be useful, but evidence is mounting that its indiscriminate use is of questionable value. In 1995, Pounds 42.6 million was spent on home monitoring of glucose in the United Kingdom (Intercontinental Medical Statistics, personal communication). Is this enormous cost justified? Is blood testing necessarily better than urine testing? Is glucose self monitoring always necessary, or is it sometimes a waste of time and money? Are recommendations for self monitoring based on sound evidence? PMID:9099125

  11. Comparison between Urine and Cervical Samples for HPV DNA Detection and Typing in Young Women in Colombia.

    PubMed

    Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina

    2016-09-01

    Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.

  12. Serial-omics characterization of equine urine

    PubMed Central

    Yuan, Min; Breitkopf, Susanne B.

    2017-01-01

    Horse urine is easily collected and contains molecules readily measurable using mass spectrometry that can be used as biomarkers representative of health, disease or drug tampering. This study aimed at analyzing microliter levels of horse urine to purify, identify and quantify proteins, polar metabolites and non-polar lipids. Urine from a healthy 12 year old quarter horse mare on a diet of grass hay and vitamin/mineral supplements with limited pasture access was collected for serial-omics characterization. The urine was treated with methyl tert-butyl ether (MTBE) and methanol to partition into three distinct layers for protein, non-polar lipid and polar metabolite content from a single liquid-liquid extraction and was repeated two times. Each layer was analyzed by high performance liquid chromatography—high resolution tandem mass spectrometry (LC-MS/MS) to obtain protein sequence and relative protein levels as well as identify and quantify small polar metabolites and lipids. The results show 46 urine proteins, many related to normal kidney function, structural and circulatory proteins as well as 474 small polar metabolites but only 10 lipid molecules. Metabolites were mostly related to urea cycle and ammonia recycling as well as amino acid related pathways, plant diet specific molecules, etc. The few lipids represented triglycerides and phospholipids. These data show a complete mass spectrometry based—omics characterization of equine urine from a single 333 μL mid-stream urine aliquot. These omics data help serve as a baseline for healthy mare urine composition and the analyses can be used to monitor disease progression, health status, monitor drug use, etc. PMID:29028822

  13. Quantitative determination of 5-hydroxy-N-methylpyrrolidone in urine for biological monitoring of N-methylpyrrolidone exposure.

    PubMed

    Ligocka, D; Lison, D; Haufroid, V

    2002-10-05

    The aim of this work was to validate a sensitive method for quantitative analysis of 5-hydroxy-N-methylpyrrolidone (5-HNMP) in urine. This compound has been recommended as a marker for biological monitoring of N-methylpyrrolidone (NMP) exposure. Different solvents and alternative methods of extraction including liquid-liquid extraction (LLE) on Chem Elut and solid-phase extraction (SPE) on Oasis HLB columns were tested. The most efficient extraction of 5-HNMP in urine was LLE with Chem Elut columns and dichloromethane as a solvent (consistently 22% of recovery). The urinary extracts were derivatized by bis(trimethylsilyl)trifluoroacetamide and analysed by gas chromatography-mass spectrometry (GC-MS) with tetradeutered 5-HNMP as an internal standard. The detection limit of this method is 0.017 mg/l urine with an intraassay precision of 1.6-2.6%. The proposed method of extraction is simple and reproducible. Four different m/z signal ratios of TMS-5-HNMP and tetralabelled TMS-5-HNMP have been validated and could be indifferently used in case of unexpected impurities from urine matrix. Copyright 2002 Elsevier Science B.V.

  14. Transformation of codeine and codeine-6-glucuronide to opioid analogues by urine adulteration with pyridinium chlorochromate: potential issue for urine drug testing.

    PubMed

    Luong, Susan; Ung, Alison T; Kalman, John; Fu, Shanlin

    2014-07-30

    Pyridinium chlorochromate (PCC) is the active ingredient of 'Urine Luck', a commercially available in vitro adulterating agent used to conceal the presence of drugs in a urine specimen. The exposure of codeine and its major glucuronide metabolite codeine-6-glucuronide (C6G) to PCC was investigated to determine whether PCC is an effective masking agent for these opiate compounds. Following the addition of PCC to both spiked and authentic codeine and C6G-positive urine specimens, the samples were monitored using liquid chromatography/mass spectrometry (LC/MS). Stable reaction products were identified and characterized using high-resolution MS analysis and, where possible, nuclear magnetic resonance (NMR) analysis. It was determined that PCC effectively oxidizes codeine and C6G, thus altering the original codeine-to-C6G ratio in the urine specimen. Four reaction products were identified for codeine: codeinone, 14-hydroxycodeinone, 6-O-methylcodeine and 8-hydroxy-7,8-dihydrocodeinone. Similarly, three reaction products were identified for C6G: codeinone, codeine and a lactone of C6G (tentative assignment). Besides addressing the complications added to interpretation, more investigation is warranted to further determine their potential for use as markers for monitoring the presence of codeine and C6G in urine specimens adulterated with PCC. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Real time monitoring to the odour of excrement for health of infants and elderly completely bedridden

    NASA Astrophysics Data System (ADS)

    Ye, Jiancheng; Huang, Guoliang

    2017-01-01

    In the domain of biomedical signals measurements, monitoring human physiological parameters is an important issue. With the rapid development of wireless body area network, it makes monitor, transmit and record physiological parameters faster and more convenient. Infants and the elderly completely bedridden are two special groups of the society who need more medical care. According to researches investigating current frontier domains and the market products, the detection of physiological parameters from the excrement is rare. However, urine and faeces contain a large number of physiological information, which are high relative to health. The mainly distributed odour from urine is NH4 and the distributed odour from feces is mainly H2S, which are both could be detected by the sensors. In this paper, we introduce the design and implementation of a portable wireless device based on body area network for real time monitoring to the odour of excrement for health of infants and the elderly completely bedridden. The device not only could monitor in real time the emitted odour of faeces and urine for health analysis, but also measures the body temperature and environment humidity, and send data to the mobile phone of paramedics to alarm or the server for storage and process, which has prospect to monitoring infants and the paralysis elderly.

  16. Assessment of the use of oral fluid as a matrix for drug monitoring in patients undergoing treatment for opioid addiction.

    PubMed

    Kunkel, Frank; Fey, Elizabeth; Borg, Damon; Stripp, Richard; Getto, Christine

    2015-01-01

    Drug testing is an important clinical tool that is available to physicians who are assessing the effectiveness of drug treatment as well as patient compliance to the administered program. While urine has traditionally been the matrix of choice for drug monitoring, oral fluid, a filtrate of the blood, has shown great promise as an alternative matrix for such applications. Oral fluid collection can be accomplished without the need for highly trained medical staff through the use of a simple, noninvasive oral fluid collection device, which obtains an adequate sample in only a few minutes. There has been a significant amount of research performed on the use of oral fluid for forensic toxicology application; however, more studies assessing the use of oral fluid drug testing are required to validate its ability to achieve clinical drug monitoring goals. Testing for various drugs in oral fluid may yield a different result when compared to the same drugs in urine, requiring an assessment of the utility of oral fluid for such practices. The purpose of this study was to examine the application of oral fluid drug testing in patients undergoing buprenorphine treatment for opioid dependence. A retrospective analysis of drug testing results obtained from 6,928 patients (4,560 unobserved urine collections and 2,368 observed oral fluid collections) monitored for heroin metabolite, amphetamine, benzodiazepines, buprenorphine, tetrahydrocannabinol, cocaine, codeine, hydrocodone, hydromorphone, methadone, morphine, oxycodone, and oxymorphone was completed. Results of this statistical exercise indicated that patients undergoing observed oral fluid collection tested positive more frequently than those unobserved urine collections for several illicit drugs and prescription medications targeted. Oral fluid was shown to detect illicit drug use as well as noncompliance in this patient population under the studied conditions more often than the urine specimens.

  17. Monitoring of drug intake during pregnancy by questionnaires and LC-MS/MS drug urine screening: evaluation of both monitoring methods.

    PubMed

    Hoeke, Henrike; Roeder, Stefan; Bertsche, Thilo; Lehmann, Irina; Borte, Michael; von Bergen, Martin; Wissenbach, Dirk K

    2015-08-01

    Various studies pointed towards a relationship between chronic diseases such as asthma and allergy and environmental risk factors, which are one aspect of the so-called Exposome. These environmental risk factors include also the intake of drugs. One critical step in human development is the prenatal period, in which exposures might have critical impact on the child's health outcome. Thereby, the health effects of drugs taken during gestation are discussed controversially with regard to newborns' disease risk. Due to this, the drug intake of pregnant women in the third trimester was monitored by questionnaire, in addition to biomonitoring using a local birth cohort study, allowing correlations of drug exposure with disease risk. Therefore, 622 urine samples were analyzed by an untargeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) urine screening and the results were compared to self-administered questionnaires. In total, 48% (n = 296) reported an intake of pharmaceuticals, with analgesics as the most frequent reported drug class in addition to dietary supplements. 182 times compounds were detected by urine screening, with analgesics (42%; n = 66) as the predominantly drug class. A comparison of reported and detected drug intake was performed for three different time spans between completion of the questionnaires and urine sampling. Even if the level of accordance was low in general, similar percentages (~25%, ~19%, and ~ 20%) were found for all groups. This study illustrates that a comprehensive evaluation of drug intake is neither achieved by questionnaires nor by biomonitoring alone. Instead, a combination of both monitoring methods, providing complementary information, should be considered. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Methods developed to elucidate nursing related adverse events in Japan.

    PubMed

    Yamagishi, Manaho; Kanda, Katsuya; Takemura, Yukie

    2003-05-01

    Financial resources for quality assurance in Japanese hospitals are limited and few hospitals have quality monitoring systems of nursing service systems. However, recently its necessity has been recognized. This study has cost effectively used adverse event occurrence rates as indicators of the quality of nursing service, and audited methods of collecting data on adverse events to elucidate their approximate true numbers. Data collection was conducted in July, August and November 2000 at a hospital in Tokyo that administered both primary and secondary health care services (281 beds, six wards, average length of stay 23 days). We collected adverse events through incident reports, logs, check-lists, nurse interviews, medication error questionnaires, urine leucocyte tests, patient interviews and medical records. Adverse events included the unplanned removals of invasive lines, medication errors, falls, pressure sores, skin deficiencies, physical restraints, and nosocomial infections. After evaluating the time and useful outcomes of each source, it soon became clear that we could elucidate adverse events most consistently and cost-effectively through incident reports, check lists, nurse interviews, urine leucocyte tests and medication error questionnaires. This study suggests that many hospitals in Japan could monitor the quality of the nursing service using these sources.

  19. Identification of the inactivating factors and mechanisms exerted on MS2 coliphage in concentrated synthetic urine.

    PubMed

    Oishi, Wakana; Sano, Daisuke; Decrey, Loic; Kadoya, Syunsuke; Kohn, Tamar; Funamizu, Naoyuki

    2017-11-15

    Volume reduction (condensation) is a key for the practical usage of human urine as a fertilizer because it enables the saving of storage space and the reduction of transportation cost. However, concentrated urine may carry infectious disease risks resulting from human pathogens frequently present in excreta, though the survival of pathogens in concentrated urine is not well understood. In this study, the inactivation of MS2 coliphage, a surrogate for single-stranded RNA human enteric viruses, in concentrated synthetic urine was investigated. The infectious titer reduction of MS2 coliphage in synthetic urine samples was measured by plaque assay, and the reduction of genome copy number was monitored by reverse transcription-quantitative PCR (RTqPCR). Among chemical-physical conditions such as pH and osmotic pressure, uncharged ammonia was shown to be the predominant factor responsible for MS2 inactivation, independently of urine concentration level. The reduction rate of the viral genome number varied among genome regions, but the comprehensive reduction rate of six genome regions was well correlated with that of the infectious titer of MS2 coliphage. This indicates that genome degradation is the main mechanism driving loss of infectivity, and that RT-qPCR targeting the six genome regions can be used as a culture-independent assay for monitoring infectivity loss of the coliphage in urine. MS2 inactivation rate constants were well predicted by a model using ion composition and speciation in synthetic urine samples, which suggests that MS2 infectivity loss can be estimated solely based on the solution composition, temperature and pH, without explicitly accounting for effects of osmotic pressure. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A Sensitive Dilute-and-Shoot Approach for the Simultaneous Screening of 71 Stimulants and 7 Metabolites in Human Urine by LC-MS-MS with Dynamic MRM.

    PubMed

    Dong, Ying; Yan, Kuan; Ma, Yanhua; Wang, Shan; He, Genye; Deng, Jing; Yang, Zhiyong

    2015-10-01

    A novel, reliable and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed with dynamic multiple reaction monitoring (dMRM) mode for the simultaneous screening of 71 stimulants and 7 metabolites in human urine using unsophisticated MS instruments (Agilent triple-quadruple 6410 B mass spectrometer). With a known retention time of an analyte, dMRM algorithm monitors each MRM transition only around its expected retention time. Therefore, dMRM enables the maximization of dwell times and provides much higher sensitivity and reproducibility than the conventional multiple reaction monitoring mode (cMRM). After precipitation of protein, the urine sample was injected into LC-MS-MS system directly without sample pre-concentration. For comparison, cMRM and dMRM acquisitions were performed under the same chromatographic conditions. The result showed that the signal response and quality of the chromatograms for each stimulant improved significantly with dMRM over cMRM. The method has been fully validated giving limits of detection (0.1-25 ng/mL) satisfactory for its application to anti-doping analysis. The repeatability of the concentrations and the retention times are good both for intra- and for inter-day experiments (%CV of concentrations always <20 and %CV of retention times <0.5). The method also afforded satisfactory results in terms of accuracy, matrix effect and specificity. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Feasibility of collecting 24-h urine to monitor sodium intake in the National Health and Nutrition Examination Survey123

    PubMed Central

    Terry, Ana L; Cogswell, Mary E; Wang, Chia-Yih; Chen, Te-Ching; Loria, Catherine M; Wright, Jacqueline D; Zhang, Xinli; Lacher, David A; Merritt, Robert K; Bowman, Barbara A

    2016-01-01

    Background: Twenty-four–hour urine sodium excretion is recommended for monitoring population sodium intake. Because of concerns about participation and completion, sodium excretion has not been collected previously in US nationally representative surveys. Objective: We assessed the feasibility of implementing 24-h urine collections as part of a nationally representative survey. Design: We selected a random half sample of nonpregnant US adults aged 20–69 y in 3 geographic locations of the 2013 NHANES. Participants received explicit instructions, started and ended the urine collection in a urine study mobile examination center, and answered questions about their collection. Among those with a complete 24-h urine collection, a random one-half were asked to collect a second 24-h urine sample. Sodium, potassium, chloride, and creatinine excretion were analyzed. Results: The final NHANES examination response rate for adults aged 20–69 y in these 3 study locations was 71%. Of those examined (n = 476), 282 (59%) were randomly selected to participate in the 24-h urine collection. Of these, 212 persons [75% of those selected for 24-h urine collection; 53% (equal to 71% × 75% of those selected for the NHANES)] collected a complete initial 24-h specimen and 92 persons (85% of 108 selected) collected a second complete 24-h urine sample. More men than women completed an initial collection (P = 0.04); otherwise, completion did not vary by sociodemographic characteristics, body mass index, education, or employment status for either collection. Mean 24-h urine volume and sodium excretion were 1964 ± 1228 mL and 3657 ± 2003 mg, respectively, for the first 24-h urine sample, and 2048 ± 1288 mL and 3773 ± 1891 mg, respectively, for the second collection. Conclusion: Given the 53% final component response rate and 75% completion rate, 24-h urine collections were deemed feasible and implemented in the NHANES 2014 on a subsample of adults aged 20–69 y to assess population sodium intake. This study was registered at clinicaltrials.gov as NCT02723682. PMID:27413136

  2. Does random urine drug testing reduce illicit drug use in chronic pain patients receiving opioids?

    PubMed

    Manchikanti, Laxmaiah; Manchukonda, Rajeev; Pampati, Vidyasagar; Damron, Kim S; Brandon, Doris E; Cash, Kim A; McManus, Carla D

    2006-04-01

    Prescription drug abuse and illicit drug use are common in chronic pain patients. Adherence monitoring with screening tests, and urine drug testing, periodic monitoring with prescription monitoring programs, has become a common practice in recent years. Random drug testing for appropriate use of opioids and use of illicit drugs is often used in pain management practices. Thus, it is expected that random urine drug testing will deter use of illicit drugs, and also improve compliance. To study the prevalence of illicit drug use in patients receiving opioids for chronic pain management and to compare the results of illicit drug use with the results from a previous study. A prospective, consecutive study. Interventional pain management practice setting in the United States. A total of 500 consecutive patients on opioids, considered to be receiving stable doses of opioids supplemental to their interventional techniques, were studied by random drug testing. Testing was performed by rapid drug screen. Results were considered positive if one or more of the monitored illicit drugs including cocaine, marijuana (THC), methamphetamine or amphetamines were present. Illicit drug use was evident in 80 patients, or 16%, with marijuana in 11%, cocaine in 5%, and methamphetamine and/or amphetamines in 2%. When compared with previous data, the overall illicit drug use was significantly less. Illicit drug use in elderly patients was absent. The prevalence of illicit drug abuse in patients with chronic pain receiving opioids continues to be a common occurence. This study showed significant reductions in overall illicit drug use with adherence monitoring combined with random urine drug testing.

  3. Monitoring Body Water Balance in Pregnant and Nursing Women: The Validity of Urine Color.

    PubMed

    McKenzie, Amy L; Armstrong, Lawrence E

    2017-01-01

    Urine osmolality (UOSM) reflects the renal regulation of excess fluid or deficit fluid, and therefore, serves as a marker of hydration status. Little is known about monitoring hydration in pregnant and lactating women despite significant physiological challenges to body water balance during that time. Therefore, we designed a study to assess if urine color (UCOL), an inexpensive and practical method, was a valid means of assessing urine concentration. Twenty-four hour UCOL was significantly correlated with 24 h UOSM in all women: pregnant, lactating, and control (r = 0.61-0.84, all p < 0.001). Utilizing a receiver operating characteristic statistical analysis, we found that 24 h and single sample UCOL had excellent diagnostic accuracy for identifying UOSM ≥500 mOsm·kg-1 in all women (area under the curve = 0.68-0.95, p < 0.001-0.46), and the UCOL that reflected this cut off was ≥4 on the UCOL chart. Therefore, UCOL is a valid marker of urine concentration and ultimately hydration status in pregnant, lactating, and non-pregnant, non-lactating women. For pregnant, lactating, and control women, the UCOL chart is a valid tool that can be used to monitor urine concentration in a single sample or over the course of the day via a 24 h sample. Key Message: Women who present with a UCOL of 4 or more likely have a UOSM ≥500 mOsm·kg-1. Given the positive health benefits associated with UOSM <500 mOsm·kg-1, women should aim for a 1, 2, or 3 on the UCOL chart. If a UCOL of ≥4 is observed, women should consider increasing fluid consumption to improve hydration status. © 2017 The Author(s) Published by S. Karger AG, Basel.

  4. Monitoring cocaine use in substance-abuse-treatment patients by sweat and urine testing.

    PubMed

    Preston, K L; Huestis, M A; Wong, C J; Umbricht, A; Goldberger, B A; Cone, E J

    1999-09-01

    Sweat and urine specimens were collected from 44 methadone-maintenance patients to evaluate the use of sweat testing to monitor cocaine use. Paired sweat patches that were applied and removed weekly (on Tuesdays) were compared with 3-5 consecutive urine specimens collected Mondays, Wednesdays, and Fridays. All patches (N = 930) were extracted in 2.5 mL of solvent and analyzed by ELISA immunoassay (cutoff concentration 10 ng/mL); a subset of patches (N = 591) was also analyzed by gas chromatography-mass spectrometry (GC-MS) for cocaine, benzoylecgonine (BZE), and ecgonine methyl ester (EME) (cutoff concentration 5 ng/mL). Urine specimens were subjected to qualitative analysis by EMIT (cutoff 300 ng/mL) and subsets were analyzed by TDx (semiquantitative, LOD 30 ng/mL) and by GC-MS for cocaine (LOD 5 ng/mL). Results were evaluated to (1) determine the relative amounts of cocaine and its metabolites in sweat; (2) assess replicability in duplicate patches; (3) compare ELISA and GC-MS results for cocaine in sweat; and (4) compare the detection of cocaine use by sweat and urine testing. Cocaine was detected by GC-MS in 99% of ELISA-positive sweat patches; median concentrations of cocaine, BZE, and EME were 378, 78.7, and 74 ng/mL, respectively. Agreement in duplicate patches was approximately 90% by ELISA analysis. The sensitivity, specificity, and efficiency of sweat ELISA cocaine results as compared with sweat GC-MS results were 93.6%, 91.3%, and 93.2%, respectively. The sensitivity, specificity, and efficiency between ELISA sweat patch and EMIT urine results were 97.6%, 60.5%, and 77.7%, respectively. These results support the use of sweat patches for monitoring cocaine use, though further evaluation is needed.

  5. Urinary Sodium-to-Potassium Ratio Tracks the Changes in Salt Intake during an Experimental Feeding Study Using Standardized Low-Salt and High-Salt Meals among Healthy Japanese Volunteers

    PubMed Central

    Yatabe, Midori Sasaki; Watanabe, Ami; Takano, Kozue; Sanada, Hironobu; Ichihara, Atsuhiro; Felder, Robin A.; Miura, Katsuyuki; Ueshima, Hirotsugu; Kimura, Junko; Yatabe, Junichi

    2017-01-01

    The Na/K ratio is considered to be a useful index, the monitoring of which allows an effective Na reduction and K increase, because practical methods (self-monitoring devices and reliable individual estimates from spot urine) are available for assessing these levels in individuals. An intervention trial for lowering the Na/K ratio has demonstrated that a reduction of the Na/K ratio mainly involved Na reduction, with only a small change in K. The present study aimed to clarify the relationship between dietary Na intake and the urinary Na/K molar ratio, using standardized low- and high-salt diets, with an equal dietary K intake, to determine the corresponding Na/K ratio. Fourteen healthy young adult volunteers ingested low-salt (3 g salt per day) and high-salt (20 g salt per day) meals for seven days each. Using a portable urinary Na/K meter, participants measured their spot urine at each voiding, and 24-h urine was collected on the last day of each diet period. On the last day of the unrestricted, low-salt, and high-salt diet periods, the group averages of the 24-h urine Na/K ratio were 4.2, 1.0, and 6.9, while the group averages of the daily mean spot urine Na/K ratio were 4.2, 1.1, and 6.6, respectively. The urinary Na/K ratio tracked changes in dietary salt intake, and reached a plateau approximately three days after each change in diet. Frequent monitoring of the spot urine Na/K ratio may help individuals adhere to an appropriate dietary Na intake. PMID:28850062

  6. Urinary Sodium-to-Potassium Ratio Tracks the Changes in Salt Intake during an Experimental Feeding Study Using Standardized Low-Salt and High-Salt Meals among Healthy Japanese Volunteers.

    PubMed

    Yatabe, Midori Sasaki; Iwahori, Toshiyuki; Watanabe, Ami; Takano, Kozue; Sanada, Hironobu; Watanabe, Tsuyoshi; Ichihara, Atsuhiro; Felder, Robin A; Miura, Katsuyuki; Ueshima, Hirotsugu; Kimura, Junko; Yatabe, Junichi

    2017-08-29

    The Na/K ratio is considered to be a useful index, the monitoring of which allows an effective Na reduction and K increase, because practical methods (self-monitoring devices and reliable individual estimates from spot urine) are available for assessing these levels in individuals. An intervention trial for lowering the Na/K ratio has demonstrated that a reduction of the Na/K ratio mainly involved Na reduction, with only a small change in K. The present study aimed to clarify the relationship between dietary Na intake and the urinary Na/K molar ratio, using standardized low- and high-salt diets, with an equal dietary K intake, to determine the corresponding Na/K ratio. Fourteen healthy young adult volunteers ingested low-salt (3 g salt per day) and high-salt (20 g salt per day) meals for seven days each. Using a portable urinary Na/K meter, participants measured their spot urine at each voiding, and 24-h urine was collected on the last day of each diet period. On the last day of the unrestricted, low-salt, and high-salt diet periods, the group averages of the 24-h urine Na/K ratio were 4.2, 1.0, and 6.9, while the group averages of the daily mean spot urine Na/K ratio were 4.2, 1.1, and 6.6, respectively. The urinary Na/K ratio tracked changes in dietary salt intake, and reached a plateau approximately three days after each change in diet. Frequent monitoring of the spot urine Na/K ratio may help individuals adhere to an appropriate dietary Na intake.

  7. Use of a hand-held bladder ultrasound scanner in the assessment of dehydration and monitoring response to treatment in a paediatric emergency department.

    PubMed

    Enright, Kevin; Beattie, Tom; Taheri, Sepideh

    2010-10-01

    Dehydration is a common concern in paediatric emergency care. Limited tools are available to assess reduced urine production, which is commonly cited as a reliable marker of dehydration. To evaluate the utility of a hand-held bladder ultrasound scanner in monitoring urine production in children attending the emergency department with suspected dehydration. A prospective pilot study was undertaken on a convenience sample of patients presenting with suspected dehydration. Serial bladder ultrasound scanning was performed to monitor urine output. Dehydration was assessed clinically using the WHO guide to dehydration assessment. Decisions about treatment and admission were made independently of the urine output measurements obtained using the bladder scanner. 45 children were studied. Using the WHO guide, 33 (73%) had mild dehydration, 8 (18%) had moderate dehydration and 4 (9%) had severe dehydration. There was a significant difference in estimated urine production between those admitted and those discharged (0.9±1.2 ml/kg/h vs 1.8±1.5 ml/kg/h, p=0.01) and between those with mild dehydration versus moderate/severe dehydration (2.3±1.5 ml/kg/h vs 0.6±0.7 ml/kg/h, p=0.0011). Urine output had been significantly reduced in those who had received an intravenous fluid bolus compared with those who had not (0.4±0.46 ml/kg/h vs 1.9±1.6 ml/kg/h, p=0.001). The hand-held bladder scanner is a convenient, non-invasive and objective adjunct in the assessment and management of children attending the emergency department with suspected dehydration.

  8. Monitoring OH-PCBs in PCB transport worker's urine as a non-invasive exposure assessment tool.

    PubMed

    Haga, Yuki; Suzuki, Motoharu; Matsumura, Chisato; Okuno, Toshihiro; Tsurukawa, Masahiro; Fujimori, Kazuo; Kannan, Narayanan; Weber, Roland; Nakano, Takeshi

    2018-06-01

    In this study, we analyzed hydroxylated polychlorinated biphenyls (OH-PCBs) in urine of both PCB transport workers and PCB researchers. A method to monitor OH-PCB in urine was developed. Urine was solid-phase extracted with 0.1% ammonia/ methanol (v/v) and glucuronic acid/sulfate conjugates and then decomposed using β-glucuronidase/arylsulfatase. After alkaline digestion/derivatization, the concentration of OH-PCBs was determined by HRGC/HRMS-SIM. In the first sampling campaign, the worker's OH-PCB levels increased several fold after the PCB waste transportation work, indicating exposure to PCBs. The concentration of OH-PCBs in PCB transport workers' urine (0.55~11 μg/g creatinine (Cre)) was higher than in PCB researchers' urine (< 0.20 μg/g Cre). However, also a slight increase of OH-PCBs was observed in the researchers doing the air sampling at PCB storage area. In the second sampling, after recommended PCB exposure reduction measures had been enacted, the worker's PCB levels did not increase during handling of PCB equipment. This suggests that applied safety measures improved the situation. Hydroxylated trichlorobiphenyls (OH-TrCBs) were identified as a major homolog of OH-PCBs in urine. Also, hydroxylated tetrachlorobiphenyls (OH-TeCBs) to hydroxylated hexachlorobiphenyls (OH-HxCBs) were detected. For the sum of ten selected major indicators, a strong correlation to total OH-PCBs were found and these can possibly be used as non-invasive biomarkers of PCB exposure in workers managing PCB capacitors and transformer oils. We suggest that monitoring of OH-PCBs in PCB management projects could be considered a non-invasive way to detect exposure. It could also be used as a tool to assess and improve PCB management. This is highly relevant considering the fact that in the next 10 years, approx. 14 million tons of PCB waste need to be managed. Also, the selected populations could be screened to assess whether exposure at work, school, or home has taken place.

  9. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    PubMed

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  10. Depleted uranium exposure and health effects in Gulf War veterans

    PubMed Central

    Squibb, Katherine S; McDiarmid, Melissa A

    2006-01-01

    Health effects stemming from depleted uranium (DU) exposure in a cohort of Gulf War veterans who were in or on US Army vehicles hit by friendly fire involving DU munitions are being carefully monitored through the Baltimore Veterans Affairs (VA) DU Follow-Up Program initiated in 1993. DU exposure in this cohort has been directly measured using inductively coupled plasma-mass spectrometer (ICP-MS) isotopic analysis for DU in urine specimens. Soldiers with embedded DU fragments continue to excrete elevated concentrations of U in their urine, documenting ongoing systemic exposure to U released from their fragments. Biennial surveillance visits provide a detailed health assessment that includes basic clinical measures and surveillance for early changes in kidney function, an expected target organ for U. Tests also include measurements of genotoxicity and neuroendocrine, neurocognitive and reproductive function. With the exception of the elevated urine U excretion, no clinically significant expected U-related health effects have been identified to date. Subtle changes in renal function and genotoxicity markers in veterans with urine U concentrations greater than 0.1 μg−1 creatinine, however, indicate the need for continued surveillance of these DU-exposed veterans. PMID:16687268

  11. [Urine metabonomic study on long-term use of total ginsenosides in rats].

    PubMed

    Xie, Xie; Chen, Shao-Qiu; Lv, Ying-Fang; Wang, Xiao-Yan; Jia, Wei

    2014-12-01

    Due to its effect of systems regulation and promotion on body, Ginseng is always referred to be long-term used as a dietary supplement. But it was still unclear about its target of the tonic effects and also the side-effects long-term use may bring. Urine metabolomic method is suitable for long-term studies of pharmaco-dynamics, pharmacology and toxicology of traditional Chinese medicine because of its characteristics of non-invasive and monitoring the whole-body metabolism. This study was designed to detect the dynamic variation of rat urine metabolome along with a long-term administration of total ginsenosides using GC-TOF based metabolomic technology. Our result showed that either short-term or chronic administration of ginsenosides did not impact the rat urine metabolome significantly (as the PCA subgroup was not successful). By comparison, the short-term (1-3 w) dose of ginsenosides had the biggest metabolic influence including TCA cycle, catecholamines and neurotransmitter amino acids. Medium-term (6-10 w) dose had a gradually lower effect and long-term (27 w) dose almost had no effect. Our study indicates that both short and long-term administration of ginsenosides showed almost no obvious side-effect on the experimental animals.

  12. Comparison of daily urine, sweat, and skin swabs among cocaine users.

    PubMed

    Kidwell, D A; Kidwell, J D; Shinohara, F; Harper, C; Roarty, K; Bernadt, K; McCaulley, R A; Smith, F P

    2003-04-23

    This study (1) compares urine, skin swabs, and PharmChek sweat patches for monitoring drug use; (2) measures possible environmental contamination in recent cocaine (COC) users; and (3) evaluates various immunoassays (IA) for screening COC in diverse matrices. Unique aspects include daily urine monitoring of 10 participants for 4 weeks, multiple monitoring methods, analysis for all specimens by IA and gas chromatography (GC)/mass spectrometry (MS), and the potential for continued illicit drug use by participants. Urine served as the "gold standard" specimen for determining drug use. Only cocaine and related substances were detected. Trace amounts of drugs were found on the skin (<50 ng per swab) of urine-negative participants' hands or forehead. In contrast, larger quantities of COC were found on the skin of individuals with BE-positive urines or individuals living with drug users (up to 20 microg per swab). Patch COC amounts among the three regular users (250-9000, 0-240, 160-22,000 ng per patch) exceeded BE (50-950, none, 30-2200 ng per patch). Pre-swabs, valuable for interpreting the source or time frame of positive patch results, contained substantial COC (38-1160, 0-152, 34-762 ng per swab) prior to patch application; therefore, patch results may represent current use, prior use, contamination, or a combination. In three individuals with no indication of cocaine use, false positives (defined as sweat patch positive when urine specimens were <300ng BE/ml) occurred at a 7% rate. Proposed cut-off concentrations of 75 ng cocaine per patch and 300 ng BE/ml urine curtail the incidence of false positives in this limited population. Three immunoassays were compared to screen specimens for cocaine: a modified, manual Microgenics CEDIA; a Cozart ELISA; and an OraSure ELISA. CEDIA's limit of detection (LOD) was 81ng/ml, compared with LODs of 4 ng/ml for the Cozart ELISA and 1.5 ng/ml for the OraSure ELISA. Cozart correlated with OraSure results for COC concentrations <2000 ng per swab (n=117), r(2)=0.79.

  13. Quantitation of lysergic acid diethylamide in urine using atmospheric pressure matrix-assisted laser desorption/ionization ion trap mass spectrometry.

    PubMed

    Cui, Meng; McCooeye, Margaret A; Fraser, Catharine; Mester, Zoltán

    2004-12-01

    A quantitative method was developed for analysis of lysergic acid diethylamide (LSD) in urine using atmospheric pressure matrix-assisted laser desorption/ionization ion trap mass spectrometry (AP MALDI-ITMS). Following solid-phase extraction of LSD from urine samples, extracts were analyzed by AP MALDI-ITMS. The identity of LSD was confirmed by fragmentation of the [M + H](+) ion using tandem mass spectrometry. The quantification of LSD was achieved using stable-isotope-labeled LSD (LSD-d(3)) as the internal standard. The [M + H](+) ion fragmented to produce a dominant fragment ion, which was used for a selected reaction monitoring (SRM) method for quantitative analysis of LSD. SRM was compared with selected ion monitoring and produced a wider linear range and lower limit of quantification. For SRM analysis of samples of LSD spiked in urine, the calibration curve was linear in the range of 1-100 ng/mL with a coefficient of determination, r(2), of 0.9917. This assay was used to determine LSD in urine samples and the AP MALDI-MS results were comparable to the HPLC/ ESI-MS results.

  14. Measurement of natural carbon isotopic composition of acetone in human urine.

    PubMed

    Yamada, Keita; Ohishi, Kazuki; Gilbert, Alexis; Akasaka, Mai; Yoshida, Naohiro; Yoshimura, Ryoko

    2016-02-01

    The natural carbon isotopic composition of acetone in urine was measured in healthy subjects using gas chromatography-combustion-isotope ratio mass spectrometry combined with headspace solid-phase microextraction (HS-SPME-GC-C-IRMS). Before applying the technique to a urine sample, we optimized the measurement conditions of HS-SPME-GC-C-IRMS using aqueous solutions of commercial acetone reagents. The optimization enabled us to determine the carbon isotopic compositions within ±0.2 ‰ of precision and ±0.3‰ of error using 0.05 or 0.2 mL of aqueous solutions with acetone concentrations of 0.3-121 mg/L. For several days, we monitored the carbon isotopic compositions and concentrations of acetone in urine from three subjects who lived a daily life with no restrictions. We also monitored one subject for 3 days including a fasting period of 24 h. These results suggest that changes in the availability of glucose in the liver are reflected in changes in the carbon isotopic compositions of urine acetone. Results demonstrate that carbon isotopic measurement of metabolites in human biological samples at natural abundance levels has great potential as a tool for detecting metabolic changes caused by changes in physiological states and disease.

  15. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    PubMed

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  16. Monitoring of PAEMs and beta-agonists in urine for a small group of experimental subjects and PAEs and beta-agonists in drinking water consumed by the same subjects.

    PubMed

    Liou, Saou-Hsing; Yang, Gordon C C; Wang, Chih-Lung; Chiu, Yu-Han

    2014-07-30

    This 5-month study contains two parts: (1) to monitor the concentrations of 11 phthalate esters metabolites (PAEMs) and two beta-agonists in human urine samples collected from a small group of consented participants including 16 females and five males; and (2) to analyze the residues of phthalate esters (PAEs) and beta-agonists in various categories of drinking water consumed by the same group of subjects. Each category of human urine and drinking water had 183 samples of its own. The analytical results showed that nine PAEMs were detected in human urine and eight PAEs were detected in drinking water samples. It was found that average concentrations of PAEMs increased as the age increased, but no significant difference between sexes. Further, using the principal component analysis, the loadings of age effect were found to be two times greater than that of gender effect in terms of four DEHP metabolites. Regarding beta-agonists of concern (i.e., ractopamine and salbutamol), they were neither detected in human urine nor drinking water samples in this study. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Design and the parametric testing of the space station prototype integrated vapor compression distillation water recovery module

    NASA Technical Reports Server (NTRS)

    Reveley, W. F.; Nuccio, P. P.

    1975-01-01

    Potable water for the Space Station Prototype life support system is generated by the vapor compression technique of vacuum distillation. A description of a complete three-man modular vapor compression water renovation loop that was built and tested is presented; included are all of the pumps, tankage, chemical post-treatment, instrumentation, and controls necessary to make the loop representative of an automatic, self-monitoring, null gravity system. The design rationale is given and the evolved configuration is described. Presented next are the results of an extensive parametric test during which distilled water was generated from urine and urinal flush water with concentration of solids in the evaporating liquid increasing progressively to 60 percent. Water quality, quantity and production rate are shown together with measured energy consumption rate in terms of watt-hours per kilogram of distilled water produced.

  18. Environmental Control and Life Support System, Water Recovery System

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The Environmental Control and Life Support System (ECLSS) Group of the Flight Projects Directorate at the Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. This is a close-up view of ECLSS Water Recovery System (WRS) racks. The MSFC's ECLSS Group overseas much of the development of the hardware that will allow a constant supply of clean water for four to six crewmembers aboard the ISS. The WRS provides clean water through the reclamation of wastewaters, including water obtained from the Space Shuttle's fuel cells, crewmember urine, used shower, handwash and oral hygiene water cabin humidity condensate, and Extravehicular Activity (EVA) wastes. The WRS is comprised of a Urine Processor Assembly (UPA), and a Water Processor Assembly (WPA). The UPA accepts and processes pretreated crewmember urine to allow it to be processed along with other wastewaters in the WPA, which removes free gas, organic, and nonorganic constituents before the water goes through a series of multifiltration beds for further purification. Product water quality is monitored primarily through conductivity measurements. Unacceptable water is sent back through the WPA for reprocessing. Clean water is sent to a storage tank. The water must meet stringent purity standards before consumption by the crew. The UPA provided by the MSFC and the WRA is provided by the prime contractor, Hamilton Sundstrand Space Systems, International (HSSSI) from Cornecticut.

  19. Realising the Potential of Urine and Saliva as Diagnostic Tools in Sport and Exercise Medicine.

    PubMed

    Lindsay, Angus; Costello, Joseph T

    2017-01-01

    Accurate monitoring of homeostatic perturbations following various psychophysiological stressors is essential in sports and exercise medicine. Various biomarkers are routinely used as monitoring tools in both clinical and elite sport settings. Blood collection and muscle biopsies, both invasive in nature, are considered the gold standard for the analysis of these biomarkers in exercise science. Exploring non-invasive methods of collecting and analysing biomarkers that are capable of providing accurate information regarding exercise-induced physiological and psychological stress is of obvious practical importance. This review describes the potential benefits, and the limitations, of using saliva and urine to ascertain biomarkers capable of identifying important stressors that are routinely encountered before, during, or after intense or unaccustomed exercise, competition, over-training, and inappropriate recovery. In particular, we focus on urinary and saliva biomarkers that have previously been used to monitor muscle damage, inflammation, cardiovascular stress, oxidative stress, hydration status, and brain distress. Evidence is provided from a range of empirical studies suggesting that urine and saliva are both capable of identifying various stressors. Although additional research regarding the efficacy of using urine and/or saliva to indicate the severity of exercise-induced psychophysiological stress is required, it is likely that these non-invasive biomarkers will represent "the future" in sports and exercise medicine.

  20. Evaluation of open versus closed urine collection systems and development of nosocomial bacteriuria in dogs.

    PubMed

    Sullivan, Lauren A; Campbell, Vicki L; Onuma, Serene C

    2010-07-15

    To determine whether use of a closed urine collection system would decrease the incidence of nosocomial bacteriuria in hospitalized dogs, compared with use of an open urine collection system (used, sterile IV bags). Randomized controlled trial. 51 hospitalized dogs requiring indwelling urinary catheterization for >or= 24 hours. Dogs were randomly assigned to an open or closed urine collection system group. A standardized protocol for catheter placement and maintenance was followed for all dogs. A baseline urine sample was collected via cystocentesis for aerobic bacterial culture, with additional urine samples obtained daily from the urine collection reservoir. 27 dogs were assigned to the open urine collection system group, and 24 were assigned to the closed urine collection system group. The incidence of nosocomial bacteriuria in dogs with open urine collection systems (3/27 [11.1%]) was not significantly different from incidence in dogs with closed urine collection systems (2/24 [8.3%]). Median duration of catheterization was 2 days for dogs in both groups; the range was 1 to 7 days for dogs in the open group and 1 to 5 days for dogs in the closed group. Results suggested that for dogs requiring short-term indwelling urinary catheterization, the type of urine collection system (open vs closed) was not associated with likelihood of developing nosocomial bacteriuria. Use of a strict protocol for urinary catheter placement and maintenance was likely key in the low incidence of nosocomial bacteriuria in the present study.

  1. Quantitative determination of famotidine in human maternal plasma, umbilical cord plasma and urine using high-performance liquid chromatography - mass spectrometry

    PubMed Central

    Wang, Xiaoming; Rytting, Erik; Abdelrahman, Doaa R.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2013-01-01

    The liquid chromatography with electrospray ionization mass spectrometry for the quantitative determination of famotidine in human urine, maternal and umbilical cord plasma was developed and validated. The plasma samples were alkalized with ammonium hydroxide and extracted twice with ethyl acetate. The extraction recovery of famotidine in maternal and umbilical cord plasma ranged from 53% to 64% and 72% to 79%, respectively. Urine samples were directly diluted with the initial mobile phase then injected into the HPLC system. Chromatographic separation of famotidine was achieved by using a Phenomenex Synergi™ Hydro-RP™ column with a gradient elution of acetonitrile and 10 mM ammonium acetate aqueous solution (pH 8.3, adjusted with ammonium hydroxide). Mass Spectrometric detection of famotidine was set in the positive mode and used a selected ion monitoring method. Carbon-13-labeled famotidine was used as internal standard. The calibration curves were linear (r2> 0.99) in the concentration ranges of 0.631-252 ng/mL for umbilical and maternal plasma samples, and of 0.075-30.0 μg/mL for urine samples. The relative deviation of method was less than 14% for intra- and inter-day assays, and the accuracy ranged between 93% and 110%. The matrix effect of famotidine in human urine, maternal and umbilical cord plasma is less than 17%. PMID:23401067

  2. Urine separating sewage systems--environmental effects and resource usage.

    PubMed

    Jönsson, H

    2002-01-01

    Effects of urine separation on the environment and resource usage were estimated using the simulation package ORWARE. Measurements on the urine-separating system in the housing district Palsternackan in Stockholm and on the fertilising effect of the urine were used in the simulations. The tenants were at home 65% of the time and separated 65% of the urine. Under these conditions, urine separation decreased the waterborne emissions of nitrogen and phosphorus by 55% and 33% respectively. Compared to the conventional system, urine separation increased the flow from the wastewater system to agriculture of plant-available nitrogen by a factor of 28, phosphorus by a factor of 1.35 and potassium by a factor of 23. Urine is a well-balanced complete fertiliser with very low concentrations of heavy metals. Urine separation conserved energy as long as the urine was transported distances shorter than 221 km to the field with a truck and trailer. If all the urine had been separated and transported only 1 km, the energy saving would have been 36%. In this and in previous studies, urine separation proved to be an improvement over the conventional system as regards environmental effects and resource usage.

  3. Detection of residual rifampicin in urine via fluorescence quenching of gold nanoclusters on paper.

    PubMed

    Chatterjee, Krishnendu; Kuo, Chiung Wen; Chen, Ann; Chen, Peilin

    2015-06-26

    Rifampicin or rifampin (R) is a common drug used to treat inactive meningitis, cholestatic pruritus and tuberculosis (TB), and it is generally prescribed for long-term administration under regulated dosages. Constant monitoring of rifampicin is important for controlling the side effects and preventing overdose caused by chronic medication. In this study, we present an easy to use, effective and less costly method for detecting residual rifampicin in urine samples using protein (bovine serum albumin, BSA)-stabilized gold nanoclusters (BSA-Au NCs) adsorbed on a paper substrate in which the concentration of rifampicin in urine can be detected via fluorescence quenching. The intensity of the colorimetric assay performed on the paper-based platforms can be easily captured using a digital camera and subsequently analyzed. The decreased fluorescence intensity of BSA-Au NCs in the presence of rifampicin allows for the sensitive detection of rifampicin in a range from 0.5 to 823 µg/mL. The detection limit for rifampicin was measured as 70 ng/mL. The BSA-Au NCs were immobilized on a wax-printed paper-based platform and used to conduct real-time monitoring of rifampicin in urine. We have developed a robust, cost-effective, and portable point-of-care medical diagnostic platform for the detection of rifampicin in urine based on the ability of rifampicin to quench the fluorescence of immobilized BSA-Au NCs on wax-printed papers. The paper-based assay can be further used for the detection of other specific analytes via surface modification of the BSA in BSA-Au NCs and offers a useful tool for monitoring other diseases.

  4. Measurement of citrate in urine using liquid chromatography tandem mass spectrometry: comparison with an enzymatic method.

    PubMed

    Keevil, B G; Owen, L; Thornton, S; Kavanagh, J

    2005-09-01

    Measurement of urine citrate is used to assess the risk of further urinary stone formation and to assess the benefit of treatment in affected individuals. We wanted to develop a simple and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the analysis of urinary citrate and to compare it with our current enzymatic assay. For the LC-MS/MS assay, samples were prepared in a deep-well block by adding 10 microL of urine and 20 microL of internal standard to 400 microL of water. After mixing, 3 microL of the diluted sample was injected into the LC-MS/MS system. An LC system was used to isocratically elute a C18 column (50 x 2.1 mm) with 0.4 mL/min water containing 2 mmol/L ammonium acetate and 0.1% (v/v) formic acid. A step gradient of 100% methanol containing 2 mmol/L ammonium acetate and 0.1% (v/v) formic acid was used to wash the column. The retention times were 1.4 min for citrate and 1.4 min for d4-citrate. Cycle time was 4.0 min, injection to injection. The analytes were monitored using a tandem mass spectrometer operated in multiple reaction monitoring mode using the following transitions, citrate m/z 191.0>111.0 and d4-citrate m/z 195.0>113.0. Within and between-batch coefficients of variation were <3% over the range 480-3800 micromol/L. The lower limit of quantification was 24.0 micromol/L. Regression analysis showed LC-MS/MS = 0.8781 (enzymatic assay) + 102.5, r = 0.964, n = 73. We have developed a simple LC-MS/MS method for urinary citrate measurement that shows acceptable performance.

  5. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  6. Monitoring hydration status pre- and post-training among university athletes using urine color and weight loss indicators.

    PubMed

    Webb, Marquitta C; Salandy, Sinead T; Beckford, Safiya E

    2016-01-01

    To investigate the hydration status pre- and post-training among university athletes using urine color and weight loss as indicators. Participants were 52 university athletes training for campus games in a developing country. Pre- and post-training urine specimens were compared with a standard urine color scale. Paired t tests were used to compare urine color and difference in body mass pre- and post-training. The mean age of the athletes was 22.87 ± 3.21. A statistically significance difference (p < .01) was observed between pre- (4.31 ± 1.75) and post- (5.67 ± 1.45) training urine color values for males. Hydration status and weight post-training were statistically significantly different both at the level of p < .01. The results suggest that there is a link between urine color and body mass difference among the student athletes tested. Exercise increases hypohydration due to fluid losses, and therefore attention should be given to fluid supplementation and individualization of fluid intake for each athlete.

  7. S-phenyl-N-acetylcysteine in urine of rats and workers after exposure to benzene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jongeneelen, F.J.; Dirven, H.A.; Leijdekkers, C.M.

    1987-05-01

    An HPLC method for the determination of S-phenyl-N-acetylcysteine in urine is described. The sensitivity is 6 mumol/L (CV = 9%) urine. Exposure of rats to six different concentrations of benzene, ranging from 0-30 ppm, was highly associated with urinary excretion of S-phenyl-N-acetylcysteine (r = 0.86) and with total phenol (r = 0.81). A background level of phenol was found in urine of both non-exposed rats and of non-exposed referents. However, no background excretion of S-phenyl-N-acetylcysteine was found, either in rats or in humans. In urine of exposed rats, the level of S-phenyl-N-acetylcysteine was approximately five times lower than the phenolmore » level. Workers occupationally exposed to benzene, showing high levels of urinary phenol, revealed low concentrations of urinary S-phenyl-N-acetylcysteine. The biological monitoring of industrial exposure to benzene by determination of S-phenyl-N-acetylcysteine in urine is not better than the determination of phenol in urine.« less

  8. Occupational exposure of electrical utility linemen to pentachlorophenol.

    PubMed

    Thind, K S; Karmali, S; House, R A

    1991-12-01

    Occupational exposure to pentachlorophenol (PCP) for a crew of electrical utility linemen was monitored over a 6-month period by using total PCP in urine per gram of creatinine as a biological monitoring parameter. Urine samples were collected from three groups: A, B, and control, at a 4-week frequency during 1989. Group A was required to use new gloves after each 4-week work period; Group B changed gloves on a need basis as per normal operating procedure. The control group consisted of members of the administrative office staff who were not occupationally exposed. The used gloves returned by Group A were monitored for contamination. On the basis of analysis of the collected data the following conclusions were noted. (1) The linemen experienced a seasonal exposure pattern with exposures peaking in July and August. This seasonal effect was also observed with glove contamination data. (2) The glove contamination levels were significantly associated with urine PCP concentrations when both these variables were expressed as geometric means for the individuals in Group A. Inclusion of work experience as an additional variable enhances this association. Less experienced linemen tended to perform more activities with higher current exposure and had higher urine and glove PCP measurements and higher correlations between these variables than more experienced linemen. (3) Over the study period, the difference in long-term exposures of Group A and Group B linemen was not statistically significant. (4) The long-term individual exposures, calculated as the geometric mean of each individual's sequential sample readings, were all below the biological monitoring guideline value of 1000 micrograms PCP/g creatinine.

  9. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  10. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  11. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  12. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  13. Dual Mechanism of Brain Injury and Novel Treatment Strategy in Maple Syrup Urine Disease

    ERIC Educational Resources Information Center

    Zinnanti, William J.; Lazovic, Jelena; Griffin, Kathleen; Skvorak, Kristen J.; Paul, Harbhajan S.; Homanics, Gregg E.; Bewley, Maria C.; Cheng, Keith C.; LaNoue, Kathryn F.; Flanagan, John M.

    2009-01-01

    Maple syrup urine disease (MSUD) is an inherited disorder of branched-chain amino acid metabolism presenting with life-threatening cerebral oedema and dysmyelination in affected individuals. Treatment requires life-long dietary restriction and monitoring of branched-chain amino acids to avoid brain injury. Despite careful management, children…

  14. Biological Monitoring of 3-Phenoxybenzoic Acid in Urine by an Enzyme -Linked Immunosorbent Assay

    EPA Science Inventory

    An enzyme-linked immunosorbent assay (ELISA) method was employed for determination of the pyrethroid biomarker, 3-phenoxybenzoic acid (3-PBA) in human urine samples. The optimized coating antigen concentration was 0.5 ng/mL with a dilution of 1:4000 for the 3-PBA antibody and 1:6...

  15. Infrared vibrational spectroscopy: a rapid and novel diagnostic and monitoring tool for cystinuria

    PubMed Central

    Oliver, Katherine V.; Vilasi, Annalisa; Maréchal, Amandine; Moochhala, Shabbir H.; Unwin, Robert J.; Rich, Peter R.

    2016-01-01

    Cystinuria is the commonest inherited cause of nephrolithiasis (~1% in adults; ~6% in children) and is the result of impaired cystine reabsorption in the renal proximal tubule. Cystine is poorly soluble in urine with a solubility of ~1 mM and can readily form microcrystals that lead to cystine stone formation, especially at low urine pH. Diagnosis of cystinuria is made typically by ion-exchange chromatography (IEC) detection and quantitation, which is slow, laboursome and costly. More rapid and frequent monitoring of urinary cystine concentration would significantly improve the diagnosis and clinical management of cystinuria. We used attenuated total reflection - Fourier transform infrared spectroscopy (ATR-FTIR) to detect and quantitate insoluble cystine in 22 cystinuric and 5 healthy control urine samples. Creatinine concentration was also determined by ATR-FTIR to adjust for urinary concentration/dilution. Urine was centrifuged, the insoluble fraction re-suspended in 5 μL water and dried on the ATR prism. Cystine was quantitated using its 1296 cm−1 absorption band and levels matched with parallel measurements made using IEC. ATR-FTIR afforded a rapid and inexpensive method of detecting and quantitating insoluble urinary cystine. This proof-of-concept study provides a basis for developing a high-throughput, cost-effective diagnostic method for cystinuria, and for point-of-care clinical monitoring PMID:27721432

  16. Determination of 232Th in urine by ICP-MS for individual monitoring purposes.

    PubMed

    Baglan, N; Cossonnet, C; Ritt, J

    2001-07-01

    Thorium is naturally occurring in various ores used for industrial purposes and has numerous applications. This paper sets out to investigate urine analysis as a suitable monitoring approach for workers potentially exposed to thorium. Due to its biokinetic behavior and its low solubility, urinary concentrations are generally very low, requiring therefore high sensitivity analytical methods. An analytical procedure has been developed for detecting 232Th concentrations of below 1 mBq L(-1) quickly and easily. Due to the long half-life (1.41 x 10(10) y) of 232Th, the potential of a procedure based on urine sample dilution and ICP-MS (inductively coupled plasma-mass spectrometry) measurement was investigated first. Two dilution factors were chosen: 100, which is more suitable for long-term measurement trials, and 20, which increases sensitivity. It has been shown that a 100-fold dilution can be used to measure concentrations of below 1 mBq L(-1), whereas a 20-fold one can be used to reach concentrations of below 0.06 mBq L(-1). Then, on the basis of the limitation of the procedure based on urine dilution, the suitable field of application for the different procedures (100-fold and 20-fold dilution and also a chemical purification followed by an ICP-MS measurement) was determined in relation to monitoring objectives.

  17. Proposal for single and mixture biological exposure limits for sevoflurane and nitrous oxide at low occupational exposure levels.

    PubMed

    Accorsi, Antonio; Valenti, Simona; Barbieri, Anna; Raffi, Giovanni Battista; Violante, Francesco Saverio

    2003-03-01

    Assessment of individual exposures to sevoflurane plus nitrous oxide (N(2)O) by biological monitoring of unmodified analytes in post-shift urine of exposed personnel. Anaesthetics in urine and breathing area were monitored in 124 subjects in 11 operating theatres. Passive samplers were collected after 2.5-7 h of exposure, at the same time as post-shift urinary samples, to evaluate the individual time-weighted average (TWA) exposures to sevoflurane and N(2)O. A static headspace sampler coupled with a gas chromatograph mass spectrometer was used for analytical determinations (sensitivity sufficient to reveal biological/environmental exposures of 0.1 microg/l(urine) and 50 ppb for sevoflurane, and 1 microg/l(urine) and 80 ppb for N(2)O). Median (range) post-shift urinary and environmental values were 1.2 microg/l(urine) (0.1-5.0) and 0.4 ppm (0.05-3.0) for sevoflurane ( n=107) and 10.9 microg/l(urine) (0.5-74.9) and 8.6 ppm (0.2-123.4) for N(2)O ( n=121) (all low-exposure range). At log-log regression, urinary levels closely correlated with environmental data (sevoflurane, r(2)=0.7538; N(2)O, r(2)=0.8749). Biological equivalent limits (BELs) based on National Institute for Occupational Safety and Health (NIOSH) TWA exposure limits, calculated as means of regression slope and y-intercept, were 3.6 microg/l(urine) for sevoflurane (corresponding to 2 ppm) and 22.3 microg/l(urine) for N(2)O (corresponding to 25 ppm). Individual "mixture BELs", which we calculated by applying the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) mix formula to biomarker values and using the obtained NIOSH-based BELs as a reference, closely correlated with mixture TLVs (rho=0.816, Lin's concordance test). CONCLUSIONS. We propose urinary sevoflurane as a new, specific, internal dose biomarker for routine biological monitoring of personal exposures among operating-theatre personnel, and use of reliable "mixture BELs" to provide safer levels of internal exposure for workers exposed to mixtures of sevoflurane and N(2)O, and conceivably also to other mixtures of toxicants with possible additive effects.

  18. Evaluation of sulfur isotopic enrichment of urine metabolites for the differentiation of healthy and prostate cancer mice after the administration of 34S labelled yeast.

    PubMed

    Galilea San Blas, Oscar; Moreno Sanz, Fernando; Herrero Espílez, Pilar; Sainz Menéndez, Rosa María; Mayo Barallo, Juan Carlos; Marchante-Gayón, Juan Manuel; García Alonso, José Ignacio

    2017-01-01

    Sulfur isotopic enrichment of urine metabolites in healthy and prostate cancer mice using 34 S enriched yeast and High Performance Liquid Chromatography coupled to Multicollector Inductively Coupled Plasma Mass Spectrometry (HPLC-MC-ICP-MS) has been evaluated. A 30 weeks experiment (since the eleventh to the fortieth week of life) was carried out collecting the urine of three healthy mice and three transgenic mice with prostate cancer during 24h after a single oral administration of a 34 S enriched yeast slurry. The isotopic enrichment of different sulphur metabolites was monitored by coupling a C18 reverse phase HPLC column with a multicollector ICP-MS using a membrane desolvating system. Quantification of sulfur in the chromatographic peaks was carried out by post-column isotope dilution using a 33 S enriched spike. Differences between the 34 S enrichment in the urine metabolites of healthy and prostate cancer mice were found from the beginning of the disease. Both populations could be differentiated using a principal component analysis (PCA). Finally, 7 unknown mice were correctly classified in each population using a linear discriminant analysis. Copyright © 2016 Elsevier GmbH. All rights reserved.

  19. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that measures directly or indirectly the volume or flow of urine from a patient, either during the course of... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urine flow or volume measuring system. 876.1800...

  20. Stamping SERS for creatinine sensing

    NASA Astrophysics Data System (ADS)

    Li, Ming; Du, Yong; Zhao, Fusheng; Zeng, Jianbo; Santos, Greggy M.; Mohan, Chandra; Shih, Wei-Chuan

    2015-03-01

    Urine can be obtained easily, readily and non-invasively. The analysis of urine can provide metabolic information of the body and the condition of renal function. Creatinine is one of the major components of human urine associated with muscle metabolism. Since the content of creatinine excreted into urine is relatively constant, it is used as an internal standard to normalize water variations. Moreover, the detection of creatinine concentration in urine is important for the renal clearance test, which can monitor the filtration function of kidney and health status. In more details, kidney failure can be imminent when the creatinine concentration in urine is high. A simple device and protocol for creatinine sensing in urine samples can be valuable for point-of-care applications. We reported quantitative analysis of creatinine in urine samples by using stamping surface enhanced Raman scattering (S-SERS) technique with nanoporous gold disk (NPGD) based SERS substrate. S-SERS technique enables label-free and multiplexed molecular sensing under dry condition, while NPGD provides a robust, controllable, and high-sensitivity SERS substrate. The performance of S-SERS with NGPDs is evaluated by the detection and quantification of pure creatinine and creatinine in artificial urine within physiologically relevant concentration ranges.

  1. Toxicokinetic study of pyrrole adducts and its potential application for biological monitoring of 2,5-hexanedione subacute exposure.

    PubMed

    Yin, Hong-Yin; Guo, Ying; Song, Fu-Yong; Zeng, Tao; Xie, Ke-Qin

    2014-08-01

    The formation of pyrrole adducts might be responsible for peripheral nerve injury caused by n-hexane, but there is not an effective biomarker for monitoring occupational exposure of n-hexane. The current study was designed to investigate the changes of pyrrole adducts in serum and urine of rats exposed to 2,5-hexanedione (2,5-HD) and analyze the correlation between pyrrole adducts and 2,5-HD. Two groups of male Wistar rats (n = 8) were administered a single dose of 200 and 400 mg/kg 2,5-HD (i.p.), and another two groups (n = 8) were given daily dose of 200 and 400 mg/kg 2,5-HD (i.p.) for 5 days. Pyrrole adducts and 2,5-HD in serum and urine were determined, at different time points after dosing, using Ehrlich’s reagent and gas chromatography, respectively. The levels of pyrrole adducts in serum accumulated in a time-dependant manner after repeated exposure to 2,5-HD, while pyrrole adducts in urine, and 2,5-HD in serum and urine were kept stable. The half-life times (t1/2) of 2,5-HD and pyrrole adducts in serum were 2.27 ± 0.28 and 25.3 ± 3.34 h, respectively. Furthermore, the levels of pyrrole adducts in urine were significantly correlated with the levels of 2,5-HD in serum (r = 0.736, P < 0.001) and urine (r = 0.730, P < 0.001), and the levels of pyrrole adducts in serum were correlated with the cumulative dosage of 2,5-HD (r = 0.965, P < 0.001). The results suggested that pyrrole adducts in serum and urine might be markers of chronic exposure to n-hexane or 2,5-HD.

  2. Detecting DNA methylation of the BCL2, CDKN2A and NID2 genes in urine using a nested methylation specific polymerase chain reaction assay to predict bladder cancer.

    PubMed

    Scher, Michael B; Elbaum, Michael B; Mogilevkin, Yakov; Hilbert, David W; Mydlo, Jack H; Sidi, A Ami; Adelson, Martin E; Mordechai, Eli; Trama, Jason P

    2012-12-01

    Detection of methylated DNA has been shown to be a good biomarker for bladder cancer. Bladder cancer has the highest recurrence rate of any cancer and, as such, patients are regularly monitored using invasive diagnostic techniques. As urine is easily attainable, bladder cancer is an optimal cancer to detect using DNA methylation. DNA methylation is highly specific in cancer detection. However, it is difficult to detect because of the limited amount of DNA present in the urine of patients with bladder cancer. Therefore, an improved, sensitive and noninvasive diagnostic test is needed. We developed a highly specific and sensitive nested methylation specific polymerase chain reaction assay to detect the presence of bladder cancer in small volumes of patient urine. The genes assayed for DNA methylation are BCL2, CDKN2A and NID2. The regions surrounding the DNA methylation sites were amplified in a methylation independent first round polymerase chain reaction and the amplification product from the first polymerase chain reaction was used in a real-time methylation specific polymerase chain reaction. Urine samples were collected from patients receiving treatment at Wolfson Medical Center in Holon, Israel. In a pilot clinical study using patient urine samples we were able to differentiate bladder cancer from other urogenital malignancies and nonmalignant conditions with a sensitivity of 80.9% and a specificity of 86.4%. We developed a novel methylation specific polymerase chain reaction assay for the detection and monitoring of bladder cancer using DNA extracted from patient urine. The assay may also be combined with other diagnostic tests to improve accuracy. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. PubMed

    Poupeau, Céline; Roland, Christel; Bussières, Jean-François

    2016-01-01

    There is increasing evidence that traces of hazardous drugs occur in the urine of health care professionals who are exposed to these drugs. To review the scientific literature regarding urinary monitoring of health care professionals exposed to antineoplastic drugs through their work. A search of PubMed using the Medical Subject Headings 'occupational exposure' and 'antineoplastic agents' and of Google Scholar using the terms 'antineoplastic', 'urine', and 'occupational exposure'. The analysis covered all articles in English or French pertaining to health care professionals exposed to hazardous drugs in the workplace, published from January 1, 2010, to December 31, 2015. Articles that did not discuss the results of urine tests and those concerning veterinarians, as well as literature reviews, editorials, letters to the editor, and conference abstracts, were excluded. Twenty-four articles were retained. The studies were conducted in 52 health care institutions in 7 countries. They included 826 workers exposed to hazardous drugs and 175 controls, specifically nurses ( n = 16 studies), pharmacists ( n = 10), pharmacy technicians ( n = 8), physicians ( n = 7), health care aides ( n = 2), and others ( n = 8). Various analytical methods were used to quantify the presence of 13 hazardous drugs, primarily cyclophosphamide ( n = 16 studies), platinum-based drugs ( n = 7), and alpha-fluoro-beta-alanine, a urine metabolite derived from 5-fluorouracil ( n = 3). The proportion of workers with positive results ranged from 0% ( n = 10 studies) to 100% ( n = 4). Considering only those studies that allowed calculation of the rate of workers with at least one positive urine sample ( n = 23), the total proportion was 21% (173/809 workers, for all methods and drugs combined). Twenty-four studies on urine monitoring were conducted in 7 countries between 2010 and 2015. In several studies, no traces of drugs were detected in urine.

  4. On-Demand Urine Analyzer

    NASA Technical Reports Server (NTRS)

    Farquharson, Stuart; Inscore, Frank; Shende, Chetan

    2010-01-01

    A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

  5. Feasibility study of the RenalGuard™ balanced hydration system: a novel strategy for the prevention of contrast-induced nephropathy in high risk patients.

    PubMed

    Dorval, Jean-Francois; Dixon, Simon R; Zelman, Richard B; Davidson, Charles J; Rudko, Robert; Resnic, Frederic S

    2013-06-20

    Contrast-induced nephropathy (CIN) is a frequent complication following angiographic procedures with significant impact on healthcare costs, and long-term outcomes. Multiple reno-protective strategies have been studied but few have shown benefit in prospective randomized studies beyond limiting the exposure to iodinated contrast and adequate intravenous. We studied the performance and safety of a novel system designed to achieve precise real-time high volume fluid balance using a closed loop hydration monitoring and infusion system. This prospective, multi-center, FDA approved phase II feasibility study was designed to evaluate the safety and the performance of the RenalGuard matched hydration system. Between October 2006 and November 2007, twenty-three subjects at high risk for CIN (with an estimated glomerular filtration rate (eGFR)<50ml/min/1.73m(2)) undergoing diagnostic or therapeutic catheterization were treated with the system. The primary endpoint of the study was defined as the ability of the system to effectively dynamically match fluid administration to urine output. The 23 subjects at high risk for CIN enrolled had a mean±SD eGFR of 39±9.3. Patients achieved an hourly urine flow rate of 620±400ml/h. The system had a mean effectiveness rate of 99.9% over the duration of therapy with an average saline volume infused of 3825ml closely matched, minute to minute, to urine output of 3579ml. There were no major device-related complications from the experimental therapy, though one patient developed hypokalemia requiring replacement. Two subjects (9.5%) developed CIN as defined by >0.5mg/dl or >25% rise in serum creatinine at 48-60h post contrast administration when compared with the baseline. The study confirmed that the RenalGuard(TM) system is safe and dynamically balances volume hydration with urine production. Further randomized studies are needed to confirm the efficacy of the system in reducing the incidence of CIN. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Quantitation of iothalamate in urine and plasma using liquid chromatography electrospray tandem mass spectrometry (HPLC-ESI-MS/MS).

    PubMed

    Molinaro, Ross J; Ritchie, James C

    2010-01-01

    The following chapter describes a method to measure iothalamate in plasma and urine samples using high performance liquid chromatography combined with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Methanol and water are spiked with the internal standard (IS) iohexol. Iothalamate is isolated from plasma after IS spiked methanol extraction and from urine by IS spiked water addition and quick-spin filtration. The plasma extractions are dried under a stream of nitrogen. The residue is reconstituted in ammonium acetate-formic acid-water. The reconstituted plasma and filtered urine are injected into the HPLC-ESI-MS/MS. Iothalamate and iohexol show similar retention times in plasma and urine. Quantification of iothalamate in the samples is made by multiple reaction monitoring using the hydrogen adduct mass transitions, from a five-point calibration curve.

  7. Four-man rated dual catalyst system for the recovery of water from urine

    NASA Technical Reports Server (NTRS)

    Budininkas, P.

    1978-01-01

    The catalytic system was integrated with a 4-man rated urine wick evaporator. During operation, urine vapor produced by the wick-evaporator was treated in the catalytic system to remove ammonia and volatile hydrocarbons, and water was recovered by condensation in a water cooled condenser. The system operated completely automatically and required no manual adjustments, except periodic supply of urine and removal of the recovered water. Although the system was designed for treating 0.325 kg urine per hour, this rate could be achieved only with a fresh wick, then gradually decreased as the wick became saturated with urine solids. The average urine treatment rates achieved during each of the three endurance tests were 0.137, 0.217, and 0.235 kg/hr. The quality of the recovered water meets drinking water standards, with the exception of a generally low pH.

  8. Delta-9-tetrahydrocannabinolic acid A (THC-A) in urine of a 15-month-old child: A case report.

    PubMed

    Morini, Luca; Quaiotti, Jessica; Moretti, Matteo; Osculati, Antonio Marco Maria; Tajana, Luca; Groppi, Angelo; Vignali, Claudia

    2018-05-01

    The acidic forms of cannabinoids, THC-A and CBD-A are naturally present in cannabis plants and preparations and are generally decarboxylated to the active compounds before the use (e.g. thermally decarboxylated through smoking). Hence, the identification of the acidic compounds in urine could be an evidence of cannabis ingestion rather than a passive exposure to smoke. This case report described a 15-month-old child that suffered an acute intoxication by accidental cannabis ingestion. It is important to assess the ingestion and to discriminate it from a passive exposure to better interpret the clinical findings and to establish the correct therapeutic procedure. Urine samples were simply diluted in deionized water and directly injected in the LC-MS/MS system. D 3 -THCCOOH was used as internal standard. Chromatographic separation of THCCOOH, THC-A and CBD-A was carried out in reversed phase on a c18 column. A triple quad in MRM negative mode was used to monitor the three analytes. The developed LC-MS/MS method was simple and fast. A LOD of 3.0ng/mL and a LOQ of 10.0ng/mL were measured for the three compounds. The analytical procedure was validated accordingly to international guidelines. The two urine samples collected from the 15-month-old child at the hospitalization and after three days provided positive results for THCCOOH (130.0 and 10.0ng/mL respectively). THC-A was found only in the urine sample collected at the hospitalization (concentration: 70.0ng/mL). THC-A was detected and quantitated in a urine sample of a 15-month-old child. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Human arsenic poisoning issues in central-east Indian locations: biomarkers and biochemical monitoring.

    PubMed

    Pandey, Piyush Kant; Yadav, Sushma; Pandey, Madhurima

    2007-03-01

    The study reports the use of three biomarkers i.e. total arsenic in hair and nails, total arsenic in blood, and total arsenic in urine to identify or quantify arsenic exposure and concomitant health effects. The main source of arsenic was inorganic exposure through drinking water. The arsenic levels and the health effects were analyzed closely in a family having maximum symptoms of arsenic. Based on the result of this study it is reported that there exist a correlation between the clinically observable symptoms, the blood and urine arsenic level, and the arsenic intake through drinking water. An intensive study on the urinary arsenic levels was carried out in which the urine levels of arsenic and the urine sufficiency tests were performed. A composite picture of body burden of arsenic has been obtained by carrying out a complete biochemical analysis of a maximum affected family. This confirms pronounced chronic exposure of the arsenic to these people. A combined correlation study on the arsenic levels measured in whole blood, urine, hair, nails and age present a remarkable outcome. Accordingly, the arsenic levels in blood are negatively correlated with the urine arsenic levels, which indicate either the inadequacy of the renal system in cleaning the blood arsenic or a continuous recirculation of the accumulated arsenic. This is an important conclusion about arsenical metabolism in humans. The study also raises the issues of the prospects of complete elimination of the accumulated arsenic and the reversibility of the health effects. Based on the work in Kourikasa village we report that there are very remote chances of complete purging of arsenic and thus reversibility of the health effects owing to various factors. The paper also discusses the various issues concerning the chronic arsenic poisoning management in the affected locations.

  10. The determination of polycyclic aromatic hydrocarbons in human urine by high-resolution gas chromatography-mass spectrometry.

    PubMed

    Cho, Sung-Hee; Lee, Sun-Kyung; Kim, Chong Hyeak

    2018-05-01

    Polycyclic aromatic hydrocarbons (PAHs), organic compounds formed by at least two condensed aromatic rings, are ubiquitous environmental pollutants that are produced by incomplete combustion of organic materials. PAHs have been classified as carcinogenIC to humans by the International Agency for Research on Cancer, because they can bind to DNA, causing mutations. Therefore, the levels of PAHs in human urine can be used as an indicator for potential carcinogenesis and cell mutation. An analytical method was developed for the accurate measurement of PAHs in urine using high-resolution gas chromatography-mass spectrometry. Urine samples were extracted by an Oasis HLB extraction cartridge after enzymatic hydrolysis with a β-glucuronidase/arylsulfatase cocktail. The 18 PAHs were separated using an Agilent DB-5 MS capillary column (30 m × 0.25 mm, 0.25 μm) and monitored by time-of-flight mass spectrometry. Under the optimized method, the linearity of calibration curves was >0.994. The limits of detection at a signal-to-noise ratio of 3 were 10-100 ng/L. The coefficients of variation were in the range of 0.4-9.0%. The present method was highly accurate for simultaneous determination of 18 PAHs in human urine and could be applied to monitoring and biomedical investigations to check exposure of PAHs. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Criterion values for urine-specific gravity and urine color representing adequate water intake in healthy adults.

    PubMed

    Perrier, E T; Bottin, J H; Vecchio, M; Lemetais, G

    2017-04-01

    Growing evidence suggests a distinction between water intake necessary for maintaining a euhydrated state, and water intake considered to be adequate from a perspective of long-term health. Previously, we have proposed that maintaining a 24-h urine osmolality (U Osm ) of ⩽500 mOsm/kg is a desirable target for urine concentration to ensure sufficient urinary output to reduce renal health risk and circulating vasopressin. In clinical practice and field monitoring, the measurement of U Osm is not practical. In this analysis, we calculate criterion values for urine-specific gravity (U SG ) and urine color (U Col ), two measures which have broad applicability in clinical and field settings. A receiver operating characteristic curve analysis performed on 817 urine samples demonstrates that a U SG ⩾1.013 detects U Osm >500 mOsm/kg with very high accuracy (AUC 0.984), whereas a subject-assessed U Col ⩾4 offers high sensitivity and moderate specificity (AUC 0.831) for detecting U Osm >500 m Osm/kg.

  12. Retrograde contamination and practical handling of urine-meters: a comparison of three systems for the measurement of hourly diuresis in an experimental bladder-drainage model and in clinical use.

    PubMed

    Rasmussen, A; Frimodt-Møller, N; Espersen, F; Roed, M; Frimodt-Møller, C

    1996-08-01

    To compare three different urine metering systems for their ability to prevent retrograde contamination in an in vitro model of a closed urinary drainage system and for qualities important to their practical handling in a clinical setting. Using three urine-meters (the Braun Ureofix 511, the Kendall Curity 4000 and the Unoplast Unometer 500) the in vitro model was constantly flushed with a solution of Mueller-Hinton broth diluted with saline. On the first day, the urine collecting bag was inoculated with 10(8) cells of Pseudomonas aeruginosa. The system was operated for 12 days with daily sampling of the model bladder to detect any contamination. After 12 days the experiment was stopped and sampling performed at various locations, including the urine-meter and the tubing. Nine of each type of urine-meter were tested, i.e. three in three different experiments. In the clinical study, 45 patients were randomized to each of the three urine-meters and the nurses attending them were asked to complete a questionnaire on the practical handling of the urine-meters. When the urine-meters was omitted from the model system, the 'bladder' became contaminated with the test bacteria within 3 days. None of the nine Unometer 500 systems became contaminated, compared with four of each of the other two systems (P < 0.05). In clinical use, the Unometer 500 and Ureofix 511 were easier to suspend and empty than was the Curity 4000. The Unometer 500 was significantly easier to handle when the collecting bag was emptied. Urine-meters can prevent retrograde contamination in a closed bladder-drainage model, but the degree of prevention depends upon the type of urine-meter. In daily practice, there were differences in the ease of suspension of the systems and in the emptying of the urine-meter and collecting bag.

  13. Estimation of Daily Proteinuria in Patients with Amyloidosis by Using the Protein-To-Creatinine ratio in Random Urine Samples.

    PubMed

    Talamo, Giampaolo; Mir Muhammad, A; Pandey, Manoj K; Zhu, Junjia; Creer, Michael H; Malysz, Jozef

    2015-02-11

    Measurement of daily proteinuria in patients with amyloidosis is recommended at the time of diagnosis for assessing renal involvement, and for monitoring disease activity. Renal involvement is usually defined by proteinuria >500 mg/day. We evaluated the accuracy of the random urine protein-to-creatinine ratio (Pr/Cr) in predicting 24 hour proteinuria in patient with amyloidosis. We compared results of random urine Pr/Cr ratio and concomitant 24-hour urine collections in 44 patients with amyloidosis. We found a strong correlation (Spearman's ρ=0.874) between the Pr/Cr ratio and the 24 hour urine protein excretion. For predicting renal involvement, the optimal cut-off point of the Pr/Cr ratio was 715 mg/g. The sensitivity and specificity for this point were 91.8% and 95.5%, respectively, and the area under the curve value was 97.4%. We conclude that the random urine Pr/Cr ratio could be useful in the screening of renal involvement in patients with amyloidosis. If validated in a prospective study, the random urine Pr/Cr ratio could replace the 24 hour urine collection for the assessment of daily proteinuria and presence of nephrotic syndrome in patients with amyloidosis.

  14. Estimation of nitrite in source-separated nitrified urine with UV spectrophotometry.

    PubMed

    Mašić, Alma; Santos, Ana T L; Etter, Bastian; Udert, Kai M; Villez, Kris

    2015-11-15

    Monitoring of nitrite is essential for an immediate response and prevention of irreversible failure of decentralized biological urine nitrification reactors. Although a few sensors are available for nitrite measurement, none of them are suitable for applications in which both nitrite and nitrate are present in very high concentrations. Such is the case in collected source-separated urine, stabilized by nitrification for long-term storage. Ultraviolet (UV) spectrophotometry in combination with chemometrics is a promising option for monitoring of nitrite. In this study, an immersible in situ UV sensor is investigated for the first time so to establish a relationship between UV absorbance spectra and nitrite concentrations in nitrified urine. The study focuses on the effects of suspended particles and saturation on the absorbance spectra and the chemometric model performance. Detailed analysis indicates that suspended particles in nitrified urine have a negligible effect on nitrite estimation, concluding that sample filtration is not necessary as pretreatment. In contrast, saturation due to very high concentrations affects the model performance severely, suggesting dilution as an essential sample preparation step. However, this can also be mitigated by simple removal of the saturated, lower end of the UV absorbance spectra, and extraction of information from the secondary, weaker nitrite absorbance peak. This approach allows for estimation of nitrite with a simple chemometric model and without sample dilution. These results are promising for a practical application of the UV sensor as an in situ nitrite measurement in a urine nitrification reactor given the exceptional quality of the nitrite estimates in comparison to previous studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Reagent- and separation-free measurements of urine creatinine concentration using stamping surface enhanced Raman scattering (S-SERS)

    PubMed Central

    Li, Ming; Du, Yong; Zhao, Fusheng; Zeng, Jianbo; Mohan, Chandra; Shih, Wei-Chuan

    2015-01-01

    We report a novel reagent- and separation-free method for urine creatinine concentration measurement using stamping surface enhanced Raman scattering (S-SERS) technique with nanoporous gold disk (NPGD) plasmonic substrates, a label-free, multiplexed molecular sensing and imaging technique recently developed by us. The performance of this new technology is evaluated by the detection and quantification of creatinine spiked in three different liquids: creatinine in water, mixture of creatinine and urea in water, and creatinine in artificial urine within physiologically relevant concentration ranges. Moreover, the potential application of our method is demonstrated by creatinine concentration measurements in urine samples collected from a mouse model of nephritis. The limit of detection of creatinine was 13.2 nM (0.15 µg/dl) and 0.68 mg/dl in water and urine, respectively. Our method would provide an alternative tool for rapid, cost-effective, and reliable urine analysis for non-invasive diagnosis and monitoring of renal function. PMID:25798309

  16. The Potential Role of Oral Fluid in Antidoping Testing

    PubMed Central

    Anizan, Sebastien; Huestis, Marilyn A.

    2015-01-01

    BACKGROUND Currently, urine and blood are the only matrices authorized for antidoping testing by the World Anti-Doping Agency (WADA). Although the usefulness of urine and blood is proven, issues remain for monitoring some drug classes and for drugs prohibited only in competition. The alternative matrix oral fluid (OF) may offer solutions to some of these issues. OF collection is easy, noninvasive, and sex neutral and is directly observed, limiting potential adulteration, a major problem for urine testing. OF is used to monitor drug intake in workplace, clinical toxicology, criminal justice, and driving under the influence of drugs programs and potentially could complement urine and blood for antidoping testing in sports. CONTENT This review outlines the present state of knowledge and the advantages and limitations of OF testing for each of the WADA drug classes and the research needed to advance OF testing as a viable alternative for antidoping testing. SUMMARY Doping agents are either prohibited at all times or prohibited in competition only. Few OF data from controlled drug administration studies are available for substances banned at all times, whereas for some agents prohibited only in competition, sufficient data may be available to suggest appropriate analytes and cutoffs (analytical threshold concentrations) to identify recent drug use. Additional research is needed to characterize the disposition of many banned substances into OF; OF collection methods and doping agent stability in OF also require investigation to allow the accurate interpretation of OF tests for antidoping monitoring. PMID:24153253

  17. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    PubMed

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  18. Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.

    PubMed

    Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P

    2014-11-01

    The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.

  19. One-year enzyme-linked immunosorbent assay follow-up of human interleukin for Da cells/leukemia inhibitory factor in blood and urine of 22 kidney transplant recipients.

    PubMed

    Morel, D; Taupin, J L; Combe, C; Potaux, L; Gualde, N; Moreau, J F

    1994-12-15

    The cytokine human interleukin for Da cells/leukemia inhibitory factor (HILDA/LIF) exerts multiple biological effects in vitro. In mice, high circulating levels of HILDA/LIF induce a wide range of pathophysiological events, some of them closely involved with immunological and inflammatory responses. Using a sandwich ELISA recognizing the natural human HILDA/LIF molecule with a threshold of 50 pg/ml in urine and 150 pg/ml in plasma, we monitored the urine and plasma HILDA/LIF levels of 22 patients in their first year after a kidney transplant. HILDA/LIF urine excretion is increased during acute rejection, and infections also trigger heavy HILDA/LIF plasma concentrations or urine excretion. In addition, this study raises the question of HILDA/LIF involvement in post-kidney-transplant phenomena such as hypercalcemia, osteoporosis, or the reversal of anemia.

  20. Getting Out of Orbit: Water Recycling Requirements and Technology Needs for Long Duration Missions Away from Earth

    NASA Technical Reports Server (NTRS)

    Barta, Daniel J.

    2017-01-01

    Deep-space crewed missions will not have regular access to the Earth's resources or the ability to rapidly return to Earth if a system fails. As crewed missions extend farther from Earth for longer periods, habitation systems must become more self-sufficient and reliable for safe, healthy, and sustainable human exploration. For human missions to Mars, Environmental Control and Life Support Systems (ECLSS) must be able operate for up to 1,100 days with minimal spares and consumables. These missions will require capabilities to more fully recycle atmospheric gases and wastewater to substantially reduce mission costs. Even with relatively austere requirements for use, water represents one of the largest consumables by mass. Systems must be available to extract and recycle water from all sources of waste. And given that there will be no opportunity to send samples back to Earth for analysis, analytical measurements will be limited to monitoring hardware brought on board the spacecraft. The Earth Reliant phase of NASA's exploration strategy includes leveraging the International Space Station (ISS) to demonstrate advanced capabilities for a robust and reliable ECLSS. The ISS Water Recovery System (WRS) includes a Urine Processor Assembly (UPA) for distillation and recovery of water from urine and a Water Processor Assembly (WPA) to process humidity condensate and urine distillate into potable water. Possible enhancements to more fully "close the water loop" include recovery of water from waste brines and solid wastes. A possible game changer is the recovery of water from local planetary resources through use of In Situ Resource Utilization (ISRU) technologies. As part of the development and demonstration sequence, NASA intends to utilize cis-Lunar space as a Proving Ground to verify systems for deep space habitation by conducting extended duration missions to validate our readiness for Mars.

  1. DNA single strand breakage, DNA adducts, and sister chromatid exchange in lymphocytes and phenanthrene and pyrene metabolites in urine of coke oven workers.

    PubMed Central

    Popp, W; Vahrenholz, C; Schell, C; Grimmer, G; Dettbarn, G; Kraus, R; Brauksiepe, A; Schmeling, B; Gutzeit, T; von Bülow, J; Norpoth, K

    1997-01-01

    OBJECTIVES: To investigate the specificity of biological monitoring variables (excretion of phenanthrene and pyrene metabolites in urine) and the usefulness of some biomarkers of effect (alkaline filter elution, 32P postlabelling assay, measurement of sister chromatid exchange) in workers exposed to polycyclic aromatic hydrocarbons (PAHs). METHODS: 29 coke oven workers and a standardised control group were investigated for frequencies of DNA single strand breakage, DNA protein cross links (alkaline filter elution assay), sister chromatid exchange, and DNA adducts (32P postlabelling assay) in lymphocytes. Phenanthrene and pyrene metabolites were measured in 24 hour urine samples. 19 different PAHs (including benzo(a)pyrene, pyrene, and phenanthrene) were measured at the workplace by personal air monitoring. The GSTT1 activity in erythrocytes and lymphocyte subpopulations in blood was also measured. RESULTS: Concentrations of phenanthrene, pyrene, and benzo(a)pyrene in air correlated well with the concentration of total PAHs in air; they could be used for comparisons of different workplaces if the emission compositions were known. The measurement of phenanthrene metabolites in urine proved to be a better biological monitoring variable than the measurement of 1-hydroxypyrene. Significantly more DNA strand breaks in lymphocytes of coke oven workers were found (alkaline filter elution assay); the DNA adduct rate was not significantly increased in workers, but correlated with exposure to PAHs in a semiquantitative manner. The number of sister chromatid exchanges was lower in coke oven workers but this was not significant; thus counting sister chromatid exchanges was not a good variable for biomonitoring of coke oven workers. Also, indications for immunotoxic influences (changes in lymphocyte subpopulations) were found. CONCLUSIONS: The measurement of phenanthrene metabolites in urine seems to be a better biological monitoring variable for exposure to PAHs than measurement of hydroxypyrene. The alkaline filter elution assay proved to be the most sensitive biomarker for genotoxic damage, whereas the postlabelling assay was the only one with some specificity for DNA alterations caused by known compounds. PMID:9155778

  2. Use of LC-HRMS in full scan-XIC mode for multi-analyte urine drug testing - a step towards a 'black-box' solution?

    PubMed

    Stephanson, N N; Signell, P; Helander, A; Beck, O

    2017-08-01

    The influx of new psychoactive substances (NPS) has created a need for improved methods for drug testing in toxicology laboratories. The aim of this work was to design, validate and apply a multi-analyte liquid chromatography-high-resolution mass spectrometry (LC-HRMS) method for screening of 148 target analytes belonging to the NPS class, plant alkaloids and new psychoactive therapeutic drugs. The analytical method used a fivefold dilution of urine with nine deuterated internal standards and injection of 2 μl. The LC system involved a 2.0 μm 100 × 2.0 mm YMC-UltraHT Hydrosphere-C 18 column and gradient elution with a flow rate of 0.5 ml/min and a total analysis time of 6.0 min. Solvent A consisted of 10 mmol/l ammonium formate and 0.005% formic acid, pH 4.8, and Solvent B was methanol with 10 mmol/l ammonium formate and 0.005% formic acid. The HRMS (Q Exactive, Thermo Scientific) used a heated electrospray interface and was operated in positive mode with 70 000 resolution. The scan range was 100-650 Da, and data for extracted ion chromatograms used ± 10 ppm tolerance. Product ion monitoring was applied for confirmation analysis and for some selected analytes also for screening. Method validation demonstrated limited influence from urine matrix, linear response within the measuring range (typically 0.1-1.0 μg/ml) and acceptable imprecision in quantification (CV <15%). A few analytes were found to be unstable in urine upon storage. The method was successfully applied for routine drug testing of 17 936 unknown samples, of which 2715 (15%) contained 52 of the 148 analytes. It is concluded that the method design based on simple dilution of urine and using LC-HRMS in extracted ion chromatogram mode may offer an analytical system for urine drug testing that fulfils the requirement of a 'black box' solution and can replace immunochemical screening applied on autoanalyzers. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Risk factors for loss of residual renal function in children treated with chronic peritoneal dialysis.

    PubMed

    Ha, Il-Soo; Yap, Hui K; Munarriz, Reyner L; Zambrano, Pedro H; Flynn, Joseph T; Bilge, Ilmay; Szczepanska, Maria; Lai, Wai-Ming; Antonio, Zenaida L; Gulati, Ashima; Hooman, Nakysa; van Hoeck, Koen; Higuita, Lina M S; Verrina, Enrico; Klaus, Günter; Fischbach, Michel; Riyami, Mohammed A; Sahpazova, Emilja; Sander, Anja; Warady, Bradley A; Schaefer, Franz

    2015-09-01

    In dialyzed patients, preservation of residual renal function is associated with better survival, lower morbidity, and greater quality of life. To analyze the evolution of residual diuresis over time, we prospectively monitored urine output in 401 pediatric patients in the global IPPN registry who commenced peritoneal dialysis (PD) with significant residual renal function. Associations of patient characteristics and time-variant covariates with daily urine output and the risk of developing oligoanuria (under 100 ml/m(2)/day) were analyzed by mixed linear modeling and Cox regression analysis including time-varying covariates. With an average loss of daily urine volume of 130 ml/m(2) per year, median time to oligoanuria was 48 months. Residual diuresis significantly subsided more rapidly in children with glomerulopathies, lower diuresis at start of PD, high ultrafiltration volume, and icodextrin use. Administration of diuretics significantly reduced oligoanuria risk, whereas the prescription of renin-angiotensin system antagonists significantly increased the risk oligoanuria. Urine output on PD was significantly associated in a negative manner with glomerulopathies (-584 ml/m(2)) and marginally with the use of icodextrin (-179 ml/m(2)) but positively associated with the use of biocompatible PD fluid (+111 ml/m(2)). Children in both Asia and North America had consistently lower urine output compared with those in Europe perhaps due to regional variances in therapy. Thus, in children undergoing PD, residual renal function depends strongly on the cause of underlying kidney disease and may be modifiable by diuretic therapy, peritoneal ultrafiltration, and choice of PD fluid.

  4. Risk factors for loss of residual renal function in children treated with chronic peritoneal dialysis

    PubMed Central

    Ha, Il-Soo; Yap, Hui K; Munarriz, Reyner L; Zambrano, Pedro H; Flynn, Joseph T; Bilge, Ilmay; Szczepanska, Maria; Lai, Wai-Ming; Antonio, Zenaida L; Gulati, Ashima; Hooman, Nakysa; van Hoeck, Koen; Higuita, Lina M S; Verrina, Enrico; Klaus, Günter; Fischbach, Michel; Riyami, Mohammed A; Sahpazova, Emilja; Sander, Anja; Warady, Bradley A; Schaefer, Franz

    2015-01-01

    In dialyzed patients, preservation of residual renal function is associated with better survival, lower morbidity, and greater quality of life. To analyze the evolution of residual diuresis over time, we prospectively monitored urine output in 401 pediatric patients in the global IPPN registry who commenced peritoneal dialysis (PD) with significant residual renal function. Associations of patient characteristics and time-variant covariates with daily urine output and the risk of developing oligoanuria (under 100 ml/m2/day) were analyzed by mixed linear modeling and Cox regression analysis including time-varying covariates. With an average loss of daily urine volume of 130 ml/m2 per year, median time to oligoanuria was 48 months. Residual diuresis significantly subsided more rapidly in children with glomerulopathies, lower diuresis at start of PD, high ultrafiltration volume, and icodextrin use. Administration of diuretics significantly reduced oligoanuria risk, whereas the prescription of renin–angiotensin system antagonists significantly increased the risk oligoanuria. Urine output on PD was significantly associated in a negative manner with glomerulopathies (−584 ml/m2) and marginally with the use of icodextrin (−179 ml/m2) but positively associated with the use of biocompatible PD fluid (+111 ml/m2). Children in both Asia and North America had consistently lower urine output compared with those in Europe perhaps due to regional variances in therapy. Thus, in children undergoing PD, residual renal function depends strongly on the cause of underlying kidney disease and may be modifiable by diuretic therapy, peritoneal ultrafiltration, and choice of PD fluid. PMID:25874598

  5. Simultaneous determination of loxoprofen and its diastereomeric alcohol metabolites in human plasma and urine by a simple HPLC-UV detection method.

    PubMed

    Choo, K S; Kim, I W; Jung, J K; Suh, Y G; Chung, S J; Lee, M H; Shim, C K

    2001-06-01

    A simple, reliable HPLC-UV detection method was developed for the simultaneous determination of loxoprofen and its metabolites (i.e. trans- and cis-alcohol metabolites), in human plasma and urine samples. The method involves the addition of a ketoprofen (internal standard) solution in methanol, zinc sulfate solution and acetonitrile to plasma and urine samples, followed by centrifugation. An aliquot of the supernatant was evaporated to dryness, and the residue reconstituted in a mobile phase (acetonitrile:water=35:65 v/v, pH 3.0). An aliquot of the solution was then directly injected into the HPLC system. Separations were performed on octadecylsilica column (250x4.5 mm, 5 microm) with a guard column (3.2x1.5 cm, 7 microm) at ambient temperature. Loxoprofen and the metabolites in the eluent were monitored at 220 nm (a.u.f.s. 0.005). Coefficients of variations (CV%) and recoveries for loxoprofen and its metabolites were below 10 and over 96%, respectively, in the 200 approximately 15000 ng ml(-1) range for plasma and 500 approximately 50000 ng ml(-1) range for urine. Calibration curves for all the compounds in the plasma and urine were linear over the above-mentioned concentration ranges with a common correlation coefficient of 0.999. The detection limit of the present method was 100 ng for all the compounds. These results indicate that the present method is very simple and readily applicable to routine bioavailability studies of these compounds with an acceptable sensitivity.

  6. Variation in Gas and Volatile Compound Emissions from Human Urine as It Ages, Measured by an Electronic Nose.

    PubMed

    Esfahani, Siavash; Sagar, Nidhi M; Kyrou, Ioannis; Mozdiak, Ella; O'Connell, Nicola; Nwokolo, Chuka; Bardhan, Karna D; Arasaradnam, Ramesh P; Covington, James A

    2016-01-25

    The medical profession is becoming ever more interested in the use of gas-phase biomarkers for disease identification and monitoring. This is due in part to its rapid analysis time and low test cost, which makes it attractive for many different clinical arenas. One technology that is showing promise for analyzing these gas-phase biomarkers is the electronic nose--an instrument designed to replicate the biological olfactory system. Of the possible biological media available to "sniff", urine is becoming ever more important as it is easy to collect and to store for batch testing. However, this raises the question of sample storage shelf-life, even at -80 °C. Here we investigated the effect of storage time (years) on stability and reproducibility of total gas/vapour emissions from urine samples. Urine samples from 87 patients with Type 2 Diabetes Mellitus were collected over a four-year period and stored at -80 °C. These samples were then analyzed using FAIMS (field-asymmetric ion mobility spectrometry--a type of electronic nose). It was discovered that gas emissions (concentration and diversity) reduced over time. However, there was less variation in the initial nine months of storage with greater uniformity and stability of concentrations together with tighter clustering of the total number of chemicals released. This suggests that nine months could be considered a general guide to a sample shelf-life.

  7. Microbe Detector

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The AutoMicrobic System (AMS) represents years of intensive research and development by McDonnell Douglas Corp. that originated with a NASA study aimed at development of a fully automated microbial detection and identification system for spacecraft use. A urine specimen is placed into the system, where it is subjected to different freeze-dried microbe nutrients for the nine most common pathogens. An electro-optical scanner studies each specimen once an hour through a 4-to-13 hour cycle, operating automatically. Changes in cell growths on each culture are monitored by computer. The presence of pathogens is indicated when growth reaches a predetermined level. The system also enumerates the pathogens and specifies the type. Developed initially to handle urine testing, AMS soon is expected to allow analyses of blood, spinal fluid, and other body fluids. An additional capability under development is "susceptibility testing," or the determination of which microbe-killing agents-such as penicillin or other antibiotics-would be most effective in eliminating the pathogens. The whole process of detecting, identifying, and enumerating the pathogens and determining susceptibility is accomplished in less half the time required for the manual procedure. The AMS minimizes human error, reduces technician time , and increases laboratory output.

  8. A dilute-and-shoot flow-injection tandem mass spectrometry method for quantification of phenobarbital in urine.

    PubMed

    Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan

    2017-01-15

    Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Ten years of preanalytical monitoring and control: Synthetic Balanced Score Card Indicator

    PubMed Central

    López-Garrigós, Maite; Flores, Emilio; Santo-Quiles, Ana; Gutierrez, Mercedes; Lugo, Javier; Lillo, Rosa; Leiva-Salinas, Carlos

    2015-01-01

    Introduction Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC). Materials and methods We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square. Results There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients. Conclusion We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system. PMID:25672466

  10. US Army Institute of Surgical Research Annual Research Progress Report for Fiscal Year 1987.

    DTIC Science & Technology

    1987-10-01

    oases, respiratory rate, chest roentgenograms), cardiovascular (blood pressure, central venous pressure, cardiac output), and renal (urine output, urine...Monitoring includes the precordial and/or esophageal stethoscope, peripheral pulse, blood pressure, central venous pressure, Swan-Ganz catheter... central venous , peripheral venous , and Swan-Ganz (7F, American Edward Laboratories, Irvine CA) catheters and an esophageal balloon were inserted. After a 2

  11. Estimation of Vasopressin Excretion in the Urine as a Method of Monitoring Vasopressin Secretion During Space Flight

    NASA Technical Reports Server (NTRS)

    Moran, W. H.

    1972-01-01

    It is demonstrated that, under the circumstances of space flight, the measurement of plasma ADH levels might be misleading and that only the urinary ADH levels provide reliable information. The results of a partially completed survey of ADH levels in urine samples from human subjects in which simultaneous plasma ADH levels were available are included.

  12. Protocol for accuracy of point of care (POC) or in-office urine drug testing (immunoassay) in chronic pain patients: a prospective analysis of immunoassay and liquid chromatography tandem mass spectometry (LC/MS/MS).

    PubMed

    Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D; Brandon, Doris E

    2010-01-01

    Therapeutic use, overuse, abuse, and diversion of controlled substances in managing chronic non-cancer pain continues to be an issue for physicians and patients. It has been stated that physicians, along with the public and federal, state, and local government; professional associations; and pharmaceutical companies all share responsibility for preventing abuse of controlled prescription drugs. The challenge is to eliminate or significantly curtail abuse of controlled prescription drugs while still assuring the proper treatment of those patients. A number of techniques, instruments, and tools have been described to monitor controlled substance use and abuse. Thus, multiple techniques and tools available for adherence monitoring include urine drug testing in conjunction with prescription monitoring programs and other screening tests. However, urine drug testing is associated with multiple methodological flaws. Multiple authors have provided conflicting results in relation to diagnostic accuracy with differing opinions about how to monitor adherence in a non-systematic fashion. Thus far, there have not been any studies systematically assessing the diagnostic accuracy of immunoassay with laboratory testing. A diagnostic accuracy study of urine drug testing. An interventional pain management practice, a specialty referral center, a private practice setting in the United States. To compare the information obtained by point of care (POC) or in-office urine drug testing (index test) to the information found when all drugs and analytes are tested by liquid chromatography tandem mass spectroscopy (LC/MS/MS) reference test in the same urine sample. The study is designed to include 1,000 patients with chronic pain receiving controlled substances. The primary outcome measure is the diagnostic accuracy. Patients will be tested for various controlled substances, including opioids, benzodiazepines, and illicit drugs. The diagnostic accuracy study is performed utilizing the Standards for Reporting of Diagnostic Accuracy Studies (STARD) initiative which established reporting guidelines for diagnostic accuracy studies to improve the quality of reporting. The prototypical flow diagram of diagnostic accuracy study as described by STARD will be utilized. Results of diagnostic accuracy and correlation of clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics will be calculated. The limitations include lack of availability of POC testing with lower cutoff levels. This article presents a protocol for a diagnostic accuracy study of urine drug testing. The protocol also will permit correlation of various clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics. NCT 01052155.

  13. Lung function, biological monitoring, and biological effect monitoring of gemstone cutters exposed to beryls

    PubMed Central

    Wegner, R.; Heinrich-Ramm, R.; Nowak, D.; Olma, K.; Poschadel, B.; Szadkowski, D.

    2000-01-01

    OBJECTIVES—Gemstone cutters are potentially exposed to various carcinogenic and fibrogenic metals such as chromium, nickel, aluminium, and beryllium, as well as to lead. Increased beryllium concentrations had been reported in the air of workplaces of beryl cutters in Idar-Oberstein, Germany. The aim of the survey was to study the excretion of beryllium in cutters and grinders with occupational exposure to beryls—for example, aquamarines and emeralds—to examine the prevalence of beryllium sensitisation with the beryllium lymphocyte transformation test (BeLT), to examine the prevalence of lung disease induced by beryllium, to describe the internal load of the respective metals relative to work process, and to screen for genotoxic effects in this particular profession.
METHODS—In a cross sectional investigation, 57 out of 100 gemstone cutters working in 12 factories in Idar-Oberstein with occupational exposure to beryls underwent medical examinations, a chest radiograph, lung function testing (spirometry, airway resistance with the interrupter technique), and biological monitoring, including measurements of aluminium, chromium, and nickel in urine as well as lead in blood. Beryllium in urine was measured with a newly developed direct electrothermal atomic absorption spectroscopy technique with a measurement limit of 0.06 µg/l. Also, cytogenetic tests (rates of micronuclei and sister chromatid exchange), and a BeLT were performed. Airborne concentrations of beryllium were measured in three factories. As no adequate local control group was available, the cutters were categorised into those with an exposure to beryls of >4 hours/week (group A) and ⩽4 hours/week (group B).
RESULTS—Clinical, radiological, or spirometric abnormalities indicating pneumoconiosis were detected in none of the gemstone cutters. Metal concentrations in biological material were far below the respective biological limit values, and beryllium in urine was only measurable in subjects of group A. Cytogenetic investigations showed normal values which were independent of the duration of beryllium exposure. In one subject, the BeLT was positive. Beryllium stimulation indices were significantly higher in subjects with detectable beryllium in the urine than in those with beryllium concentrations below the detection limit (p<0.05). In one factory, two out of four measurements of airborne beryllium concentrations were well above the German threshold limit value of 2 µg/m3 (twofold and 10-fold), and all gemstone cutters working in this factory had measurable beryllium concentrations in urine.
CONCLUSION—No adverse clinical health effects were found in this cross sectional investigation of gemstone cutters working with beryls. However, an improvement in workplace hygiene is recommended, accompanied by biological monitoring of beryllium in urine.


Keywords: gemstone cutter; beryllium in urine; lymphocyte transformation test PMID:10711282

  14. Neopterin, kynurenine and tryptophan as new biomarkers for early detection of rectal anastomotic leakage.

    PubMed

    Dusek, Tomas; Orhalmi, Julius; Sotona, Otakar; Krcmova, Lenka Kujovska; Javorska, Lenka; Dolejs, Josef; Paral, Jiri

    2018-03-01

    At present, there are no strong predictors, nor a useful scoring system, that clearly identifies patients at risk for anastomotic leakage. This study aimed to investigate a new method that assesses this risk by monitoring levels of neopterin, tryptophan, and kynurenine, in bodily fluids. This prospective study included patients who underwent elective rectal resection for carcinoma. The basic condition for inclusion was rectal anastomosis using the double-stapling technique. Preoperative levels of neopterin, tryptophan, kynurenine, and their ratios, were assessed with blood and urine samples. These levels were then monitored for 6 postoperative days in venous blood, urine, and abdominal drainage fluid. A total of 42 patients were enrolled in the study. Thirty-six patients underwent a laparoscopic resection and 6 patients had an open procedure. No differences were found among neopterin, tryptophan, and kynurenine serum levels. However, the groups were observed to have significant differences in the urinary neopterin/creatinine ratio: the preoperative neopterin/creatinine ratio was 139.5 μmol/mol in the group with leakage, vs 114.8 μmol/mol in the group without complications, p = 0.037. The same results were observed during the postoperative period, p = 0.012. Additionally, the group with complications had a higher mean value of neopterin in drainage fluid, p = 0.048. Our study demonstrated that high preoperative levels of urinary neopterin could be interpreted as a risk for anastomotic leakage. Moreover, pathological levels of neopterin in urine and abdominal drainage fluid could be useful for early identification of anastomotic leakage during the postoperative period prior to its clinical development.

  15. Food and waste management biotechnology for the space shuttle

    NASA Technical Reports Server (NTRS)

    Murray, R. W.; Schelkopf, J. D.; Hunt, S. R.; Sauer, R. L.

    1979-01-01

    Space-crew facilities for preparation, eating, personal hygiene and waste management are contained in one small area of the Shuttle Orbiter Mid-Deck, all the functional systems being interconnected. The paper discusses three major systems: (1) the Galley, which includes the personal hygiene station and food packages; (2) the Waste Collector, which includes provisions for male and female users, urine, feces and emesis collection in both a normal and contigency mode of operation; and (3) Biowaste Monitoring, which includes mass measurement and sampling. The technology improvement continues by assuring that the Orbiter systems have sufficient design flexibility to permit later improvements in operation and in function.

  16. Spacelab 4: Primate experiment support hardware

    NASA Astrophysics Data System (ADS)

    Fusco, P. R.; Peyran, R. J.

    1984-05-01

    A squirrel monkey feeder and automatic urine collection system were designed to fly on the Spacelab 4 Shuttle Mission presently scheduled for January 1986. Prototypes of the feeder and urine collection systems were fabricated and extensively tested on squirrel monkeys at the National Aeronautics and Space Administration's (NASA) Ames Research Center (ARC). The feeder design minimizes impact on the monkey's limited space in the cage and features improved reliability and biocompatibility over previous systems. The urine collection system is the first flight qualified, automatic urine collection device for squirrel monkeys. Flight systems are currently being fabricated.

  17. Spacelab 4: Primate experiment support hardware

    NASA Technical Reports Server (NTRS)

    Fusco, P. R.; Peyran, R. J.

    1984-01-01

    A squirrel monkey feeder and automatic urine collection system were designed to fly on the Spacelab 4 Shuttle Mission presently scheduled for January 1986. Prototypes of the feeder and urine collection systems were fabricated and extensively tested on squirrel monkeys at the National Aeronautics and Space Administration's (NASA) Ames Research Center (ARC). The feeder design minimizes impact on the monkey's limited space in the cage and features improved reliability and biocompatibility over previous systems. The urine collection system is the first flight qualified, automatic urine collection device for squirrel monkeys. Flight systems are currently being fabricated.

  18. Elimination and Concentration Correlations between Edible Tissues and Biological Fluids and Hair of Ractopamine in Pigs and Goats Fed with Ractopamine-Medicated Feed.

    PubMed

    Huang, Lingli; Shi, Jingfei; Pan, Yuanhu; Wang, Liye; Chen, Dongmei; Xie, Shuyu; Liu, Zhenli; Yuan, Zonghui

    2016-03-09

    Ractopamine (RAC), a β-adrenergic leanness-enhancing agent, endangers the food safety of animal products because of overdosing and illegal use in food animals. Excretion and residue depletion of RAC in pigs and goats were investigated to determine a representative biological fluid or surface tissue for preslaughter monitoring. After a single oral gavage of RAC, 64-67% of the dose was excreted from the urine of pigs and goats within 12-24 h. RAC persisted the longest in the hair of pigs and goats but depleted rapidly in the plasma, muscle, and fat. Urine and hair were excellent for predicting RAC residues in edible tissues of pigs, whereas plasma and urine were satisfactory body fluids for the prediction of RAC concentrations in edible tissues of goats. These data provided a simple and economical preslaughter living monitoring method for the illegal use and violative residue of RAC in food animals.

  19. Urine Pretreat Injection System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    A new method of introducing the OXONE (Registered Trademark) Monopersulfate Compound for urine pretreat into a two-phase urine/air flow stream has been successfully tested and evaluated. The feasibility of this innovative method has been established for purposes of providing a simple, convenient, and safe method of handling a chemical pretreat required for urine processing in a microgravity space environment. Also, the Oxone portion of the urine pretreat has demonstrated the following advantages during real time collection of 750 pounds of urine in a Space Station design two-phase urine Fan/Separator: Eliminated urine precipitate buildup on internal hardware and plumbing; Minimized odor from collected urine; and Virtually eliminated airborne bacteria. The urine pretreat, as presently defined for the Space Station program for proper downstream processing of urine, is a two-part chemical treatment of 5.0 grams of Oxone and 2.3 ml of H2SO4 per liter of urine. This study program and test demonstrated only the addition of the proper ratio of Oxone into the urine collection system upstream of the Fan/Separator. This program was divided into the following three major tasks: (1) A trade study, to define and recommend the type of Oxone injection method to pursue further; (2) The design and fabrication of the selected method; and (3) A test program using high fidelity hardware and fresh urine to demonstrate the method feasibility. The trade study was conducted which included defining several methods for injecting Oxone in different forms into a urine system. Oxone was considered in a liquid, solid, paste and powered form. The trade study and the resulting recommendation were presented at a trade study review held at Hamilton Standard on 24-25 October 94. An agreement was reached at the meeting to continue the solid tablet in a bag concept which included a series of tablets suspended in the urine/air flow stream. These Oxone tablets would slowly dissolve at a controlled rate providing the proper concentration in the collected urine. To implement the solid tablet in a bag approach, a design concept was completed with prototype drawings of the complete urine pretreat prefilter assembly. A successful fabrication technique was developed for retaining the Oxone tablets in a fabric casing attached to the end of the existing Space Station Waste Collection System urine prefilter assembly. The final pretreat prefilter configuration held sufficient Oxone in a tablet form to allow normal scheduled daily (or twice daily) change out of the urine filter depending on the use rate of the Space Station urine collection system. The actual tests to prove the concept were conducted using the Urine Fan/Separator assembly that was originally used in the STS-52 Design Test Objective (DTO) urinal assembly. Other related tests were conducted to demonstrate the actual minimum ratio of Oxone to urine that will control microbial growth.

  20. Expressing urine from a gel disposable diaper for biomonitoring using phthalates as an example.

    PubMed

    Liu, Liangpo; Xia, Tongwei; Guo, Lihua; Cao, Lanyu; Zhao, Benhua; Zhang, Jie; Dong, Sijun; Shen, Heqing

    2012-11-01

    The urinary metabolites of phthalates are well-accepted exposure biomarkers for adults and children older than 6 years but are not commonly used for infants owing to non-convenient sampling. In the light of this situation, a novel sampling method based on monitoring the urine expressed from the gel diaper was developed. The urine was expressed from the gel absorbent after mixing the absorbent with CaCl(2) and then collected by a laboratory-made device; the urinary phthalate metabolites were extracted and cleaned using a solid-phase extraction (SPE) column and analyzed with high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry / mass spectrometry. To evaluate the method's feasibility, the following factors were investigated: the proportion of CaCl(2) to gel absorbent, the urination volume variation and the target compounds' deposition bias in the diaper, the matrix blank of the different diaper brands, the storage stabilities and the recoveries of creatinine and phthalate metabolites in the expressed urine. Mono-methyl phthalate, mono-ethyl phthalate, mono-butyl phthalate, mono-benzyl phthalate, mono-2-ethylhexyl phthalate and mono-2-ethyl-5-oxohexyl phthalate were involved. 70-80% of the urine can be expressed from the diaper, and the expressed spiking recoveries and the limit of detection of mono-phthalates ranged from 88.5-115% and 0.21-0.50 ng/ml. The method was applied to measure phthalate metabolites in 65 gel diaper samples from 15 infants, and the pilot data suggests the infants are commonly exposed to phthalates. In summary, the method for monitoring of infant exposure to phthalates is sound and validated, and the potential health effects from the vulnerable infants' exposure to phthalates should be concerned.

  1. Extended Detection of Amphetamine and Methamphetamine in Oral Fluid.

    PubMed

    Andås, Hilde T; Enger, Asle; Øiestad, Åse Marit L; Vindenes, Vigdis; Christophersen, Asbjørg S; Huestis, Marilyn A; Øiestad, Elisabeth L

    2016-02-01

    Amphetamine and methamphetamine are popular drugs of abuse worldwide and are important components of drug monitoring programs. Windows of detection for amphetamine and methamphetamine in oral fluid after high doses have not been investigated. Repeated high-dose ingestions are likely to cause positive samples for extended periods. Common routes of administration of amphetamine/methamphetamine in Norway are oral intake or injection. The aim of this study was to investigate windows of detection for amphetamine and methamphetamine in oral fluid from drug addicts under sustained abstinence during detoxification. Twenty-five patients admitted to a closed detoxification unit were included in this study. Oral fluid samples were collected daily in the morning and evening, and urine every morning for 10 days. A blood sample was drawn during the first 5 days after admission if the patient consented. Oral fluid results were compared with urine results to determine whether a new ingestion occurred. Oral fluid was collected with the Intercept oral fluid collection device. In-house cutoff concentrations for amphetamine and methamphetamine were 6.8 and 7.5 mcg/L, respectively, in oral fluid, and 135 and 149 mcg/L, respectively, in urine. Amphetamines were detected in 11 oral fluid, 5 urine, and 2 blood specimens from 25 patients. Patients self-reported amphetamines intake of up to 0.5-2 g daily. Windows of detection for amphetamine and methamphetamine in oral fluid were up to 8 days, longer than in urine at the applied cutoff values. These data confirm that oral fluid is a viable alternative to urine for monitoring amphetamine abuse, and that these substances might be detected in oral fluid for at least 1 week after ingestion of high doses. Such long detection times were, as far as we are aware, never reported previously for oral fluid amphetamines.

  2. Validation of uranium determination in urine by ICP-MS.

    PubMed

    Bouvier-Capely, C; Baglan, N; Montègue, A; Ritt, J; Cossonnet, C

    2003-08-01

    A rapid procedure--dilution of urine+ICP-MS measurement--for the determination of uranium in urine was validated. Large ranges of concentration and isotopic composition were studied on urine samples excreted by occupationally exposed workers. The results were consistent with those obtained by fluorimetry and by alpha spectrometry after a purification procedure, two currently used techniques. However, the proposed procedure is limited for determination of the minor isotope 234U. Thus for worker monitoring, the conversion of 234U mass concentration into activity concentration can lead to an erroneous value of the effective dose, in particular for a contamination at very low level with highly enriched uranium. A solution to avoid this hazard is to perform a chemical purification prior to ICP-MS measurement to lower uncertainty and detection limit for 234U.

  3. Estimation of Daily Proteinuria in Patients with Amyloidosis by Using the Protein-To-Creatinine ratio in Random Urine Samples

    PubMed Central

    Talamo, Giampaolo; Mir Muhammad, A.; Pandey, Manoj K.; Zhu, Junjia; Creer, Michael H.; Malysz, Jozef

    2015-01-01

    Measurement of daily proteinuria in patients with amyloidosis is recommended at the time of diagnosis for assessing renal involvement, and for monitoring disease activity. Renal involvement is usually defined by proteinuria >500 mg/day. We evaluated the accuracy of the random urine protein-to-creatinine ratio (Pr/Cr) in predicting 24 hour proteinuria in patient with amyloidosis. We compared results of random urine Pr/Cr ratio and concomitant 24-hour urine collections in 44 patients with amyloidosis. We found a strong correlation (Spearman’s ρ=0.874) between the Pr/Cr ratio and the 24 hour urine protein excretion. For predicting renal involvement, the optimal cut-off point of the Pr/Cr ratio was 715 mg/g. The sensitivity and specificity for this point were 91.8% and 95.5%, respectively, and the area under the curve value was 97.4%. We conclude that the random urine Pr/Cr ratio could be useful in the screening of renal involvement in patients with amyloidosis. If validated in a prospective study, the random urine Pr/Cr ratio could replace the 24 hour urine collection for the assessment of daily proteinuria and presence of nephrotic syndrome in patients with amyloidosis. PMID:25918613

  4. PPARα-dependent increase of mouse urine output by gemfibrozil and fenofibrate.

    PubMed

    Song, Danjun; Luo, Min; Dai, Manyun; Bu, Shizhong; Wang, Weihua; Zhang, Burong; Gonzalez, Frank J; Liu, Aiming

    2017-02-01

    While gemfibrozil and fenofibrate are prescribed for anti-dyslipidemia treatment, a rational basis for the use of these drugs for treatment of dyslipidemia with concurrent metabolic syndrome has not been established. In this study, wild-type and Pparα-null mice were fed gemfibrozil- or fenofibrate-containing diets for 14 days. Urine output (24 h) was monitored, and urine, serum, and liver and kidney tissues were subjected to toxicity assessment. A 2-month challenge followed by a 2-week wash-out was performed for gemfibrozil to determine urine output and the potential toxicity. A therapeutically equivalent dose of gemfibrozil was more effective than fenofibrate in increasing urine output. This regulatory effect was not observed in Pparα-null mice. In contrast, hepatomegaly induced by fenofibrate was more pronounced than that of gemfibrozil. No significant toxicity was observed in liver or kidney in the 2-month treatment with gemfibrozil. These data demonstrated PPARα mediates the increased urine output by fibrates. Considering the relative action on hepatomegaly and the regulatory effect on urine output, gemfibrozil may be the preferable drug to increase urine output. These results revealed a new pharmacodynamic effect of clinically prescribed PPARα agonists and suggested the potential value of gemfibrozil in modification of blood pressure.

  5. Monitoring of occupational exposure to methylene chloride: sampling protocol and stability of urine samples.

    PubMed

    Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia

    2005-01-01

    A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.

  6. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  7. Detection and identification of 2-nitro-morphine and 2-nitro-morphine-6-glucuronide in nitrite adulterated urine specimens containing morphine and its glucuronides.

    PubMed

    Luong, Susan; Fu, Shanlin

    2014-03-01

    In vitro urine adulteration is a well-documented practice adopted by individuals aiming to evade detection of drug use, when required to undergo mandatory sports and workplace drug testing. Potassium nitrite is an effective urine adulterant due to its oxidizing potential, and has been shown to mask the presence of many drugs of abuse. However, limited research has been conducted to understand its mechanism of action, and to explore the possibility of the drugs undergoing direct oxidation to form stable reaction products. In this study, opiates including morphine, codeine, morphine-3-glucuronide and morphine-6-glucuronide were exposed to potassium nitrite in water and urine to mimic the process of nitrite adulteration. It was found that two stable reaction products were detected by liquid chromatography-mass spectrometry (LC-MS) when morphine and morphine-6-glucuronide were exposed to nitrite. Isolation and elucidation using spectrometric and spectroscopic techniques revealed that they were 2-nitro-morphine and 2-nitro-morphine-6-glucuronide, respectively. These reaction products were also formed when an authentic morphine-positive urine specimen was fortified with nitrite. 2-Nitro-morphine was found to be stable enough to undergo the enzymatic hydrolysis procedure and also detectable by gas chromatography-mass spectrometry (GC-MS) after forming a trimethylsilyl derivative. On the contrary, morphine-3-glucuronide did not appear to be chemically manipulated when exposed to potassium nitrite in urine. These reaction products are not endogenously produced, are relatively stable and can be monitored with both LC-MS and GC-MS confirmatory techniques. As a result, these findings have revealed the possibility for the use of 2-nitro-morphine and 2-nitro-morphine-6-glucuronide as markers for the indirect monitoring of morphine and morphine-6-glucuronide in urine specimens adulterated with nitrite. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Simultaneous quantification of eleven cannabinoids and metabolites in human urine by liquid chromatography tandem mass spectrometry using WAX-S tips

    PubMed Central

    Andersson, Maria; Scheidweiler, Karl B.; Sempio, Cristina; Barnes, Allan; Huestis, Marilyn A.

    2016-01-01

    A comprehensive cannabinoids urine quantification method may improve clinical and forensic results interpretation and is necessary to support our clinical research. A liquid chromatography tandem mass spectrometry quantification method for Δ9-tetrahydrocannabinol (THC), 11-hydroxy-THC (11-OH-THC), 11-nor-9-carboxy-THC (THCCOOH), Δ9-tetrahydrocannabinolic acid (THCAA), cannabinol (CBN), cannabidiol (CBD), cannabigerol (CBG), Δ9-tetrahydrocannabivarin (THCV), 11-nor-9-carboxy-THCV (THCVCOOH), THC-glucuronide (THC-gluc) and THCCOOH-gluc (THCCOOH-gluc) in urine was developed and validated according to the Scientific Working Group on Toxicology guidelines. Sample preparation consisted of disposable pipette extraction (WAX-S) of 200μL urine. Separation was achieved on a Kinetex C18 column using gradient elution with flow rate 0.5 mL/min, mobile phase A (10 mM ammonium acetate in water) and mobile phase B (15% methanol in acetonitrile). Total run time was 14 min. Analytes were monitored in both positive and negative ionization modes by scheduled multiple reaction monitoring. Linear ranges were 0.5–100 μg/L for THC and THCCOOH, 0.5–50 μg/L for 11-OH-THC, CBD, CBN, THCAA and THC-gluc, 1–100 μg/L for CBG, THCV and THCVCOOH and 5–500 μg/L for THCCOOH-gluc (R2>0.99). Analytical biases were 88.3–113.7%, imprecisions 3.3–14.3%, extraction efficiencies 42.4–81.5% and matrix effect −10 to 32.5%. We developed and validated a comprehensive, simple and rapid LC-MS/MS cannabinoid urine method for quantification of 11 cannabinoids and metabolites. This method is being used in a controlled cannabis administration study, investigating urine cannabinoid markers documenting recent cannabis use, chronic frequent smoking or route of drug administration and potentially improving urine cannabinoid result interpretation. PMID:27422645

  9. The U.S. Department of Veterans' Affairs depleted uranium exposed cohort at 25 Years: Longitudinal surveillance results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDiarmid, Melissa A.; Gaitens, Joanna M.; Hines,

    Background: A small group of Gulf War I veterans wounded in depleted uranium (DU) friendly-fire incidents have been monitored for health changes in a clinical surveillance program at the Veterans Affairs Medical Center, Baltimore since 1994. Methods: During the spring of 2015, an in-patient clinical surveillance protocol was performed on 36 members of the cohort, including exposure monitoring for total and isotopic uranium concentrations in urine and a comprehensive assessment of health outcomes. Results: On-going mobilization of U from embedded fragments is evidenced by elevated urine U concentrations. The DU isotopic signature is observed principally in participants possessing embedded fragments.more » Those with only an inhalation exposure have lower urine U concentration and a natural isotopic signature. Conclusions: At 25 years since first exposure to DU, an aging cohort of military veterans continues to show no U-related health effects in known target organs of U toxicity. As U body burden continues to accrue from in-situ mobilization from metal fragment depots, and increases with exposure duration, critical tissue-specific U concentration thresholds may be reached, thus recommending on-going surveillance of this veteran cohort. - Highlights: • Gulf War I veterans wounded with depleted uranium are monitored for health changes. • In 2015 in-patient clinical surveillance was performed on 36 members of the cohort. • Mobilization of U from embedded fragments is evidenced by elevated U in urine. • This cohort of continues to show no U-related health effects.« less

  10. Metabolism of isorhynchophylline in rats detected by LC-MS.

    PubMed

    Wang, Wei; Ma, Chao-Mei; Hattori, Masao

    2010-01-01

    This paper investigates the metabolic fate of isorhynchophylline (ISOR) as a main bioactive oxindole alkaloid in the traditional Chinese medicine. After oral administration of ISOR to rats, plasma, bile, urine and feces were analyzed by LC-MS. Hydroxylation of ISOR and successive glucuronidation proceeded in vitro by incubation with rat liver microsomes. ISOR was identified in plasma, 11-hydroxyisorhynchophylline 11-O--D-glucuronide (MI1) and 10-hydroxyisorhynchophylline 10-O--D-glucuronide (MI2) in bile, and free 11-hydroxyisorhynchophylline (MI3) and 10-hydroxyisorhynchophylline (MI4) in urine and feces. Within 24 h, 71.6% of ISOR was excreted into the feces (in 20.0 g) and 13.8% into the urine (in 20.0 ml) of rats after oral administration of 37.5 mg/kg. Monitoring by LC-MS showed that 8.5% of ISOR was metabolized to MI3 and MI4 in a ratio of ca. 1:1. Specific inhibition of CYP isozymes indicated that CYP2D, CYP1A1/2 and CYP2C participate in ISOR hydroxylation. ISOR was involved in the circulatory system after oral administration. Cytochrome P450 (CYP) in rat liver microsomes played a key role in ISOR hydroxylation.

  11. SERS quantitative urine creatinine measurement of human subject

    NASA Astrophysics Data System (ADS)

    Wang, Tsuei Lian; Chiang, Hui-hua K.; Lu, Hui-hsin; Hung, Yung-da

    2005-03-01

    SERS method for biomolecular analysis has several potentials and advantages over traditional biochemical approaches, including less specimen contact, non-destructive to specimen, and multiple components analysis. Urine is an easily available body fluid for monitoring the metabolites and renal function of human body. We developed surface-enhanced Raman scattering (SERS) technique using 50nm size gold colloidal particles for quantitative human urine creatinine measurements. This paper shows that SERS shifts of creatinine (104mg/dl) in artificial urine is from 1400cm-1 to 1500cm-1 which was analyzed for quantitative creatinine measurement. Ten human urine samples were obtained from ten healthy persons and analyzed by the SERS technique. Partial least square cross-validation (PLSCV) method was utilized to obtain the estimated creatinine concentration in clinically relevant (55.9mg/dl to 208mg/dl) concentration range. The root-mean square error of cross validation (RMSECV) is 26.1mg/dl. This research demonstrates the feasibility of using SERS for human subject urine creatinine detection, and establishes the SERS platform technique for bodily fluids measurement.

  12. A device for automatically measuring and supervising the critical care patient's urine output.

    PubMed

    Otero, Abraham; Palacios, Francisco; Akinfiev, Teodor; Fernández, Roemi

    2010-01-01

    Critical care units are equipped with commercial monitoring devices capable of sensing patients' physiological parameters and supervising the achievement of the established therapeutic goals. This avoids human errors in this task and considerably decreases the workload of the healthcare staff. However, at present there still is a very relevant physiological parameter that is measured and supervised manually by the critical care units' healthcare staff: urine output. This paper presents a patent-pending device capable of automatically recording and supervising the urine output of a critical care patient. A high precision scale is used to measure the weight of a commercial urine meter. On the scale's pan there is a support frame made up of Bosch profiles that isolates the scale from force transmission from the patient's bed, and guarantees that the urine flows properly through the urine meter input tube. The scale's readings are sent to a PC via Bluetooth where an application supervises the achievement of the therapeutic goals. The device is currently undergoing tests at a research unit associated with the University Hospital of Getafe in Spain.

  13. Impedimetric method for measuring ultra-low E. coli concentrations in human urine.

    PubMed

    Settu, Kalpana; Chen, Ching-Jung; Liu, Jen-Tsai; Chen, Chien-Lung; Tsai, Jang-Zern

    2015-04-15

    In this study, we developed an interdigitated gold microelectrode-based impedance sensor to detect Escherichia coli (E. coli) in human urine samples for urinary tract infection (UTI) diagnosis. E. coli growth in human urine samples was successfully monitored during a 12-h culture, and the results showed that the maximum relative changes could be measured at 10Hz. An equivalent electrical circuit model was used for evaluating the variations in impedance characteristics of bacterial growth. The equivalent circuit analysis indicated that the change in impedance values at low frequencies was caused by double layer capacitance due to bacterial attachment and formation of biofilm on electrode surface in urine. A linear relationship between the impedance change and initial E. coli concentration was obtained with the coefficient of determination R(2)>0.90 at various growth times of 1, 3, 5, 7, 9 and 12h in urine. Thus our sensor is capable of detecting a wide range of E. coli concentration, 7×10(0) to 7×10(8) cells/ml, in urine samples with high sensitivity. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Microbial ureolysis in the seawater-catalysed urine phosphorus recovery system: Kinetic study and reactor verification.

    PubMed

    Tang, Wen-Tao; Dai, Ji; Liu, Rulong; Chen, Guang-Hao

    2015-12-15

    Our previous study has confirmed the feasibility of using seawater as an economical precipitant for urine phosphorus (P) precipitation. However, we still understand very little about the ureolysis in the Seawater-based Urine Phosphorus Recovery (SUPR) system despite its being a crucial step for urine P recovery. In this study, batch experiments were conducted to investigate the kinetics of microbial ureolysis in the seawater-urine system. Indigenous bacteria from urine and seawater exhibited relatively low ureolytic activity, but they adapted quickly to the urine-seawater mixture during batch cultivation. During cultivation, both the abundance and specific ureolysis rate of the indigenous bacteria were greatly enhanced as confirmed by a biomass-dependent Michaelis-Menten model. The period for fully ureolysis was decreased from 180 h to 2.5 h after four cycles of cultivation. Based on the successful cultivation, a lab-scale SUPR reactor was set up to verify the fast ureolysis and efficient P recovery in the SUPR system. Nearly complete urine P removal was achieved in the reactor in 6 h without adding any chemicals. Terminal Restriction Fragment Length Polymorphism (TRFLP) analysis revealed that the predominant groups of bacteria in the SUPR reactor likely originated from seawater rather than urine. Moreover, batch tests confirmed the high ureolysis rates and high phosphorus removal efficiency induced by cultivated bacteria in the SUPR reactor under seawater-to-urine mixing ratios ranging from 1:1 to 9:1. This study has proved that the enrichment of indigenous bacteria in the SUPR system can lead to sufficient ureolytic activity for phosphate precipitation, thus providing an efficient and economical method for urine P recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Life cycle comparison of centralized wastewater treatment and urine source separation with struvite precipitation: Focus on urine nutrient management.

    PubMed

    Ishii, Stephanie K L; Boyer, Treavor H

    2015-08-01

    Alternative approaches to wastewater management including urine source separation have the potential to simultaneously improve multiple aspects of wastewater treatment, including reduced use of potable water for waste conveyance and improved contaminant removal, especially nutrients. In order to pursue such radical changes, system-level evaluations of urine source separation in community contexts are required. The focus of this life cycle assessment (LCA) is managing nutrients from urine produced in a residential setting with urine source separation and struvite precipitation, as compared with a centralized wastewater treatment approach. The life cycle impacts evaluated in this study pertain to construction of the urine source separation system and operation of drinking water treatment, decentralized urine treatment, and centralized wastewater treatment. System boundaries include fertilizer offsets resulting from the production of urine based struvite fertilizer. As calculated by the Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI), urine source separation with MgO addition for subsequent struvite precipitation with high P recovery (Scenario B) has the smallest environmental cost relative to existing centralized wastewater treatment (Scenario A) and urine source separation with MgO and Na3PO4 addition for subsequent struvite precipitation with concurrent high P and N recovery (Scenario C). Preliminary economic evaluations show that the three urine management scenarios are relatively equal on a monetary basis (<13% difference). The impacts of each urine management scenario are most sensitive to the assumed urine composition, the selected urine storage time, and the assumed electricity required to treat influent urine and toilet water used to convey urine at the centralized wastewater treatment plant. The importance of full nutrient recovery from urine in combination with the substantial chemical inputs required for N recovery via struvite precipitation indicate the need for alternative methods of N recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Monitoring Daily Dynamics of Early Tumor Response to Targeted Therapy by Detecting Circulating Tumor DNA in Urine

    PubMed Central

    Husain, Hatim; Melnikova, Vladislava O.; Kosco, Karena; Woodward, Brian; More, Soham; Pingle, Sandeep C.; Weihe, Elizabeth; Park, Ben Ho; Tewari, Muneesh; Erlander, Mark G.; Cohen, Ezra; Lippman, Scott M.; Kurzrock, Razelle

    2017-01-01

    Purpose Non-invasive drug biomarkers for the early assessment of tumor response can enable adaptive therapeutic decision-making and proof-of-concept studies for investigational drugs. Circulating tumor DNA (ctDNA) is released into the circulation by tumor cell turnover and has been shown to be detectable in urine. Experimental Design We tested the hypothesis that dynamic changes in epidermal growth factor receptor (EGFR) activating (exon 19del and L858R) and resistance (T790M) mutation levels detected in urine could inform tumor response within days of therapy for advanced non-small cell lung cancer (NSCLC) patients receiving osimertinib, a second line third generation anti-EGFR tyrosine kinase inhibitor. Results Eight of nine evaluable NSCLC patients had detectable T790M-mutant DNA fragments in pre-treatment baseline samples. Daily monitoring of mutations in urine indicated a pattern of intermittent spikes throughout week 1 suggesting apoptosis with an overall decrease in fragment numbers between baselines to day 7 preceding radiographic response assessed at 6-12 weeks. Conclusions These findings suggest drug-induced tumor apoptosis within days of initial dosing. Daily sampling of ctDNA may enable early assessment of patient response and proof-of-concept studies for drug development. PMID:28420725

  17. A rapid method for quantification of 242Pu in urine using extraction chromatography and ICP-MS

    DOE PAGES

    Gallardo, Athena Marie; Than, Chit; Wong, Carolyn; ...

    2017-01-01

    Occupational exposure to plutonium is generally monitored through analysis of urine samples. Typically, plutonium is separated from the sample and other actinides, and the concentration is determined using alpha spectroscopy. Current methods for separations and analysis are lengthy and require long count times. A new method for monitoring occupational exposure levels of plutonium has been developed, which requires fewer steps and overall less time than the alpha spectroscopy method. In this method, the urine is acidified, and a 239Pu internal standard is added. The urine is digested in a microwave oven, and plutonium is separated using an Eichrom TRU Resinmore » column. The plutonium is eluted, and the eluant is injected directly into the Inductively Coupled Plasma–Mass Spectrometer (ICP-MS). Compared to a direct “dilute and shoot” method, a 30-fold improvement in sensitivity is achieved. This method was validated by analyzing several batches of spiked samples. Based on these analyses, a combined standard uncertainty plot, which relates uncertainty to concentration, was produced. As a result, the MDA 95 was calculated to be 7.0 × 10 –7 μg L –1, and the Lc95 was calculated to be 3.5 × 10 –7 μg L –1 for this method.« less

  18. Normalization of urinary drug concentrations with specific gravity and creatinine.

    PubMed

    Cone, Edward J; Caplan, Yale H; Moser, Frank; Robert, Tim; Shelby, Melinda K; Black, David L

    2009-01-01

    Excessive fluid intake can substantially dilute urinary drug concentrations and result in false-negative reports for drug users. Methods for correction ("normalization") of drug/metabolite concentrations in urine have been utilized by anti-doping laboratories, pain monitoring programs, and in environmental monitoring programs to compensate for excessive hydration, but such procedures have not been used routinely in workplace, legal, and treatment settings. We evaluated two drug normalization procedures based on specific gravity and creatinine. These corrections were applied to urine specimens collected from three distinct groups (pain patients, heroin users, and marijuana/ cocaine users). Each group was unique in characteristics, study design, and dosing conditions. The results of the two normalization procedures were highly correlated (r=0.94; range, 0.78-0.99). Increases in percent positives by specific gravity and creatinine normalization were small (0.3% and -1.0%, respectively) for heroin users (normally hydrated subjects), modest (4.2-9.8%) for pain patients (unknown hydration state), and substantial (2- to 38-fold increases) for marijuana/cocaine users (excessively hydrated subjects). Despite some limitations, these normalization procedures provide alternative means of dealing with highly dilute, dilute, and concentrated urine specimens. Drug/metabolite concentration normalization by these procedures is recommended for urine testing programs, especially as a means of coping with dilute specimens.

  19. Urine metabolomics.

    PubMed

    Zhang, Aihua; Sun, Hui; Wu, Xiuhong; Wang, Xijun

    2012-12-24

    Metabolomics is a powerful technique for the discovery of novel biomarkers and elucidation of biochemical pathways to improve diagnosis, prognosis and therapy. An advantage of this approach is its ability to assess global metabolic profiles to enhance pathologic characterization. Urine is an ideal bio-medium for disease study because it is readily available, easily obtained and less complex than other body fluids. Ease of collection allows for serial sampling to monitor disease and therapeutic response. Because of this potential, this paper will review urine metabolomic analysis, discuss its significance in the post-genomic era and highlight the specific roles of endogenous small molecule metabolites in this emerging field. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Urine sampling and collection system

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.

    1971-01-01

    This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.

  1. EVALUATION OF AN ENZYME-LINKED IMMUNOSORBENT ASSAY FOR BIOLOGICAL MONITORING OF 3-PHENOXYBENZOIC ACID IN URINE

    EPA Science Inventory

    Abstract describes the development of an enzyme-linked immunosorbent assay (ELISA) method for monitoring 2,4-dichlorophenoxyacetic acid (2,4-D exposures). The ELISA is compared with a gas chromatograhy/mass spectrometry procedure. ELISA method development steps and comparative ...

  2. Mitochondrial function and tissue vitality: bench-to-bedside real-time optical monitoring system

    NASA Astrophysics Data System (ADS)

    Mayevsky, Avraham; Walden, Raphael; Pewzner, Eliyahu; Deutsch, Assaf; Heldenberg, Eitan; Lavee, Jacob; Tager, Salis; Kachel, Erez; Raanani, Ehud; Preisman, Sergey; Glauber, Violete; Segal, Eran

    2011-06-01

    Background: The involvement of mitochondria in pathological states, such as neurodegenerative diseases, sepsis, stroke, and cancer, are well documented. Monitoring of nicotinamide adenine dinucleotide (NADH) fluorescence in vivo as an intracellular oxygen indicator was established in 1950 to 1970 by Britton Chance and collaborators. We use a multiparametric monitoring system enabling assessment of tissue vitality. In order to use this technology in clinical practice, the commercial developed device, the CritiView (CRV), is tested in animal models as well as in patients. Methods and Results: The new CRV enables the optical monitoring of four different parameters, representing the energy balance of various tissues in vivo. Mitochondrial NADH is measured by surface fluorometry/reflectometry. In addition, tissue microcirculatory blood flow, tissue reflectance and oxygenation are measured as well. The device is tested both in vitro and in vivo in a small animal model and in preliminary clinical trials in patients undergoing vascular or open heart surgery. In patients, the monitoring is started immediately after the insertion of a three-way Foley catheter (urine collection) to the patient and is stopped when the patient is discharged from the operating room. The results show that monitoring the urethral wall vitality provides information in correlation to the surgical procedure performed.

  3. Middle infrared optoelectronic absorption systems for monitoring physiological glucose solutions

    NASA Astrophysics Data System (ADS)

    Martin, W. Blake

    Tight monitoring of the glucose levels for diabetic individuals is essential to control long-term complications. A definitive diabetes management system has yet to be developed for the diabetic. This research investigates the application of middle infrared absorption frequencies for monitoring glucose levels in biological solutions. Three frequencies were identified using a Fourier transform infrared spectrometer and correlated to changes in glucose concentrations. The 1035 +/- 1 cm-1 frequency was determined to be the best representative frequency. Other biological molecules contributed no significant interference to monitoring glucose absorption. A second frequency at 1193 cm-1 was suggested as a representative background absorption frequency, which could be used for more accurate glucose absorption values. Next, a quantum cascade laser optoelectronic absorption system was designed and developed to monitor glucose. After careful alignment and design, the system was used to monitor physiological glucose concentrations. Correlation at 1036 cm-1 with glucose changes was comparable to the previous results. The use of the background absorption frequency was verified. This frequency essentially acts as a calibrating frequency to adjust in real-time to any changes in the background absorption that may alter the accuracy of the predicted glucose value. An evanescent wave cavity ring-down spectroscopy technique was explored to monitor molecules in a biological solution. Visible light at 425 nm was used to monitor hemoglobin in control urine samples. An adsorption isotherm for hemoglobin was detectable to limit of 5.8 nM. Evanescent wave cavity ring-down spectroscopy would be useful for a glucose solution. Given an equivalent system designed for the middle infrared, the molar extinction coefficient of glucose allows for a detectable limit of 45 mg/dl for a free-floating glucose solution, which is below normal physiological concentrations. The future use of a hydrophobic coating could limit the adsorption of glucose to the surface but still allow physiological monitoring. Three middle infrared optoelectronic absorption systems have been designed for monitoring glucose in a physiological solution. The systems are applicable for the monitoring of glucose. These systems may lead to a useful monitoring device for the diabetic so that the universal complications associated with the disease may be limited.

  4. Environmental and biological monitoring of occupational exposure to organic micropollutants in gasoline.

    PubMed

    Senzolo, C; Frignani, S; Pavoni, B

    2001-07-01

    An exposure risk assessment of workers in a refinery production unit was undertaken. Gasoline and its main components were investigated through environmental and biological monitoring. Measured variables were environmental benzene, toluene, pentane and hexane; benzene and toluene in blood and urine; tt-MA (metabolite of benzene) in urine. Multivariate statistical analysis of the data showed that worker's exposure to the above substances fell within the limits specified by organisations such as ACGIH. Also, biological values complied with reference values (RV) for non-occupationally-exposed population. Different values of biological variables were determined by separating smokers from non-smokers: smokers had hematic and urinary benzene values significantly higher than non-smokers. During a 3-yr sampling, it was possible to identify a significant decrease of benzene in the workplace air and of hematic benzene for non-smokers. The most exposed department, one in which tank-lorries were loaded, needs further investigation and extended monitoring.

  5. Measurement of urinary calcium using AT89C51RD2 microcontroller.

    PubMed

    Neelamegam, P; Jamaludeen, A; Rajendran, A; Raghunathan, R

    2009-04-01

    A simple and inexpensive absorption technique for determination of calcium ion in urine samples is developed, comprising a light emitting diode (650 nm) as the light source and photodiode as the detector with AT89C51RD2 microcontroller. The design of the system and details of interface, calibration, and procedure of operation are explained in this paper. Software is developed to monitor sample processing and to display the results in liquid crystal display screen. With 15 microl sample volume, a linear output is obtained in the range of 2.5-7.5 mM calcium with a detection limit of 0.06 mM. Interferences from other cations such as monovalent ion and divalent ion are investigated in the expected range, which are normally present in clinical samples, and absorption changes over the pH range of 3-12 are also determined. This system has been demonstrated successfully for the successive assay of calcium in urine samples, with the results comparing well to those achieved and in good agreement with values obtained with the current clinical spectrophotometric method at 95% of confidence level.

  6. A metabolic cage for the hindlimb suspended rat

    NASA Technical Reports Server (NTRS)

    Evans, J.; Mulenburg, G. M.; Harper, J. S.; Skundberg, T. L.; Navidi, M.; Arnaud, S. B.

    1994-01-01

    Hindlimb suspension has been successfully used to simulate the effects of microgravity in rats. The cage and suspension system developed by E. R. Holton is designed to produce a headward shift of fluid and unload the hindlimbs in rodents, causing changes in bone and muscle similar to those in animals and humans exposed to spaceflight. While the Holton suspension system simulates many of the conditions observed in the spaceflight animal, it does not provide for the collection of urine and feces needed to monitor some metabolic activities. As a result, only limited information has been gathered on the nutritional status, and the gastrointestinal and renal function of animals using that model. Although commercial metabolic cages are available, they are usually cylindrical and require a centrally located suspension system and thus, do not readily permit movement of the rats. The limited floor space of commercial cages may affect comparisons with studies using the Holton model which has more than twice the living space of most commercially available cages. To take advantage of the extra living space and extensive data base that has been developed with the Holton model, Holton's cage was modified to make urine and fecal collections possible.

  7. Fast screening tests for the simultaneous detection of 11 drugs of abuse in urine specimens. A forensic epidemiology study of 28,298 cases in Tunisia.

    PubMed

    Moslah, B; Araoud, M; Nouioui, M A; Najjar, S; Amira, D; Ben Salah, N; Hedhili, A

    2018-02-01

    Forensic investigation performed on people suspected to be drug abusers covering all Tunisian cities was conducted by monitoring an epidemiological study of human urine samples surveying positive rates of consumption for drugs of abuse. The forensic investigations were conducted on a total of 28,298 arrested individuals suspected to be drug addicts during five years (January 2010-December 2015). An immunoassay screening tests to detect elevated levels of drugs classes in urine samples was performed. These screening assays provide a preliminary qualitative test result. Only positives urine specimens were analyzed with GC-MS for confirmation. Except for cannabis, the results showed insignificant number of positive cases for cocaine, ecstasy (MDMA) and amphetamine consumptions (<1%). Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Escherichia coli global gene expression in urine from women with urinary tract infection.

    PubMed

    Hagan, Erin C; Lloyd, Amanda L; Rasko, David A; Faerber, Gary J; Mobley, Harry L T

    2010-11-11

    Murine models of urinary tract infection (UTI) have provided substantial data identifying uropathogenic E. coli (UPEC) virulence factors and assessing their expression in vivo. However, it is unclear how gene expression in these animal models compares to UPEC gene expression during UTI in humans. To address this, we used a UPEC strain CFT073-specific microarray to measure global gene expression in eight E. coli isolates monitored directly from the urine of eight women presenting at a clinic with bacteriuria. The resulting gene expression profiles were compared to those of the same E. coli isolates cultured statically to exponential phase in pooled, sterilized human urine ex vivo. Known fitness factors, including iron acquisition and peptide transport systems, were highly expressed during human UTI and support a model in which UPEC replicates rapidly in vivo. While these findings were often consistent with previous data obtained from the murine UTI model, host-specific differences were observed. Most strikingly, expression of type 1 fimbrial genes, which are among the most highly expressed genes during murine experimental UTI and encode an essential virulence factor for this experimental model, was undetectable in six of the eight E. coli strains from women with UTI. Despite the lack of type 1 fimbrial expression in the urine samples, these E. coli isolates were generally capable of expressing type 1 fimbriae in vitro and highly upregulated fimA upon experimental murine infection. The findings presented here provide insight into the metabolic and pathogenic profile of UPEC in urine from women with UTI and represent the first transcriptome analysis for any pathogenic E. coli during a naturally occurring infection in humans.

  9. Development of online NIR urine analyzing system based on AOTF

    NASA Astrophysics Data System (ADS)

    Wan, Feng; Sun, Zhendong; Li, Xiaoxia

    2006-09-01

    In this paper, some key techniques on development of on-line MR urine analyzing system based on AOTF (Acousto - Optics Tunable Filter) are introduced. Problems about designing the optical system including collimation of incident light and working distance (the shortest distance for separating incident light and diffracted light) are analyzed and researched. DDS (Direct Digital Synthesizer) controlled by microprocessor is used to realize the wavelength scan. The experiment results show that this MR urine analyzing system based on. AOTF has 10000 - 4000cm -1 wavelength range and O.3ms wavelength transfer rate. Compare with the conventional Fourier Transform NIP. spectrophotometer for analyzing multi-components in urine, this system features low cost, small volume and on-line measurement function. Unscrambler software (multivariate statistical software by CAMO Inc. Norway) is selected as the software for processing the data. This system can realize on line quantitative analysis of protein, urea and creatinine in urine.

  10. Short-term emissions of ammonia and carbon dioxide from cattle urine contaminated tropical grassland microcosm.

    PubMed

    Majumdar, Deepanjan; Patel, Manoj; Drabar, Reena; Vyas, Manish

    2006-11-01

    The study was designed to understand the emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) from a single cattle urination event on a tropical grassland and underline the significance of the emissions in the context of huge animal population grazing on large pasture areas in some countries. Emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) were monitored for three weeks from a tropical grassland (dominated by Cynodon dactylon Pers.) microcosm contaminated with cow and buffalo urine. The grassland microcosms were treated with urine (50 and 100 ml of each) only once and irrigated with water once every week. Ammonia was sampled by an automatic sampling system comprising of a vacuum pump, three-way stopcocks and rubber tubing and an impinger containing suitable absorbing solution (H(2)SO(4)), connected to the tubing suitably. The sampled gas, after sucked by the vacuum pump and absorbed in H(2)SO(4), was allowed to enter the closed microcosm again maintaining internal pressure of the microcosm. Carbon dioxide was sampled by absorption in an alkali (NaOH) trap inside the microcosm. Both NH(3) and CO(2) emissions were highly variable temporally and there was no continuous increasing or decreasing emission trend with time. Respectively, 45 and 46% of total NH(3)-N were emitted within first 48 h from 50 and 100 ml cow urine application while the corresponding values for buffalo urine were 34 and 32%. Total NH(3)-N emissions, integrated for sampling days (i.e. 1, 2, 3, 4, 6, 15, 18 and 21st) were 11 and 6% in cow and 8 and 5% in buffalo urine, of the total-N added through 50 and 100 ml urine samples. Carbon dioxide emissions were standardized at 25 degrees C by using a suitable formula which were lower than actual emissions at actual soil temperature (> 25 degrees C). Carbon dioxide emission rates were classified on the basis of soil repiratory classification and classes ranged from moderately low soil activity up to unusually high soil activity, the latter observed only on very few sampling days. Grasses in the microcosm had shown appreciable growth after urine application. Although variable and somewhat unpredictable, emissions were appreciable and that too only from a patch of single urination, indicating to the huge magnitude of total emissions under the scenario of thousands of cattle grazing on hundreds of acres of grasslands in a tropical country.

  11. Synergism between urinary prothrombin fragment 1 and urine: a comparison of inhibitory activities in stone-prone and stone-free population groups.

    PubMed

    Webber, Dawn; Rodgers, Allen L; Sturrock, Edward D

    2002-09-01

    South African blacks rarely form kidney stones compared with whites. This study investigated whether purified urinary prothrombin fragment 1 (UPTF1) derived from blacks is a more potent inhibitor of calcium oxalate crystallisation than that from whites. UPTF1 was purified from the urine of both population groups and their inhibitory activities were compared in a cross-over design in which each protein was tested in ultrafiltered urine from both population groups. Coulter Multisizer, [14C]-oxalate deposition and scanning electron microscopy experiments were used to monitor crystallisation. The study has demonstrated for the first time that UPTF1 promotes nucleation and that inhibitory activity is synergistically dependent upon urine composition. The activity of the whites' UPTF1 was greater than that of the blacks in the whites' urine (e.g. particle size decrease: 31.7% vs. 25.2%), while the blacks' UPTF1 was superior to that of the whites in the blacks' urine (e.g. particle size decrease: 46.5% vs. 32.4%). In addition, when tested in their respective endogenous urines, the blacks' UPTF1 demonstrated superior inhibitory activity on an absolute scale (e.g. particle size decrease: 46.5% vs. 31.7%). Thus, the urine composition of black South Africans may influence their UPTF1 conformation, conferring greater efficacy for inhibition of calcium oxalate crystallisation.

  12. Interferences of homogentisic acid (HGA) on routine clinical chemistry assays in serum and urine and the implications for biochemical monitoring of patients with alkaptonuria.

    PubMed

    Curtis, S L; Roberts, N B; Ranganath, L R

    2014-05-01

    We have assessed the effect of elevated concentrations of homogentisic acid (HGA) as in alkaptonuria (AKU), on a range of routine chemistry tests in serum and urine. HGA was added to pooled serum and a range of assays was analysed with Roche Modular chemistries. Effects on urine were assessed by diluting normal urine with urine from a patient with AKU, adding HGA to urine and after lowering output of urinary HGA with nitisinone treatment. Serum enzymatic creatinine showed 30% negative interference with 100μmol/L HGA and >50% at 400μmol/L. Serum urate 100 to 480μmol/L was reduced up to 20% at 100 and to 50% with 400μmol/L HGA. Serum cholesterol between 3 and 11mmol/L was reduced by 0.5mmol/L with 400μmol/L HGA. Urine enzymatic creatinine and urate with >2mmol/L HGA showed concentration dependent negative interference up to 80%. A positive interference in urine total protein by benzethonium turbidometric assay was observed, with 10mmol/L HGA equivalent to 1g/L protein. Jaffe creatinine, Na, K, Cl, Mg, Ca, phosphate, ALT, GGT, ALP activities and urea in serum and or urine were not affected by increases in HGA. To avoid interferences by HGA in alkaptonuria concentration of HGA should be established before samples are assayed with peroxidase assays and benzethonium urine protein. Copyright © 2013 The Canadian Society of Clinical Chemists. All rights reserved.

  13. Targeted eco-pharmacovigilance for ketoprofen in the environment: Need, strategy and challenge.

    PubMed

    Wang, Jun; Zhao, Shu-Qi; Zhang, Meng-Ya; He, Bing-Shu

    2018-03-01

    Implementing "targeted" eco-pharmacovigilance(EPV) which focuses on individual or specific pharmaceuticals on a prioritised basis is a feasible, economical and customized approach to reduce the environmental concentrations and risks of pharmaceuticals. Non-steroidal anti-inflammatory drugs(NSAIDs) remaining in environment are a kind of priority hazard substances, due to a notable case that diclofenac residues caused the loss of more than 99% of vultures across the Indian sub-continent. Ketoprofen, as another widely used NSAID with comparable or even higher global consumption than diclofenac, in the environment has been shown to present a potential risk to non-target terrestrial and aquatic species. Based on the review of 85 articles reporting the analyses of ketoprofen residues in environment since 2010, we found that this NSAID frequently present in various environmental compartments around the world. Therefore, it is urgent to implement EPV targeting ketoprofen pollution. Here, we provide some recommendations for implementing the targeted EPV for ketoprofen, including: Closely monitoring ketoprofen in the natural environment; Reducing the residues of ketoprofen through source control; Encouraging urine source separation and treatment; Limiting the application of veterinary ketoprofen; Designing and constituting a framework system of targeted EPV. But some challenges, such as ambiguity in the accountability of the main bodies responsible for continued monitoring of ketoprofen residues, the lack of optimized urine source separation scenarios and procedure, the need for detailed design and application schemes of the framework system of targeted EPV, etc. should be addressed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Variation in Gas and Volatile Compound Emissions from Human Urine as It Ages, Measured by an Electronic Nose

    PubMed Central

    Esfahani, Siavash; Sagar, Nidhi M.; Kyrou, Ioannis; Mozdiak, Ella; O’Connell, Nicola; Nwokolo, Chuka; Bardhan, Karna D.; Arasaradnam, Ramesh P.; Covington, James A.

    2016-01-01

    The medical profession is becoming ever more interested in the use of gas-phase biomarkers for disease identification and monitoring. This is due in part to its rapid analysis time and low test cost, which makes it attractive for many different clinical arenas. One technology that is showing promise for analyzing these gas-phase biomarkers is the electronic nose—an instrument designed to replicate the biological olfactory system. Of the possible biological media available to “sniff”, urine is becoming ever more important as it is easy to collect and to store for batch testing. However, this raises the question of sample storage shelf-life, even at −80 °C. Here we investigated the effect of storage time (years) on stability and reproducibility of total gas/vapour emissions from urine samples. Urine samples from 87 patients with Type 2 Diabetes Mellitus were collected over a four-year period and stored at −80 °C. These samples were then analyzed using FAIMS (field-asymmetric ion mobility spectrometry—a type of electronic nose). It was discovered that gas emissions (concentration and diversity) reduced over time. However, there was less variation in the initial nine months of storage with greater uniformity and stability of concentrations together with tighter clustering of the total number of chemicals released. This suggests that nine months could be considered a general guide to a sample shelf-life. PMID:26821055

  15. Simultaneous drug identification in urine of sexual assault victims by using liquid chromatography tandem mass spectrometry.

    PubMed

    Lee, Hei Hwa; Chen, Suen Chi; Lee, Jong Feng; Lin, Hsin Yu; Chen, Bai Hsiun

    2018-01-01

    According to domestic and international epidemiological investigation, the proportion of substance involved sexual assault has the trend of ascent. In the past, laboratory methods that investigated urine sample of the sexual assault victims was to screen with enzyme immunoassay and then confirmed with mass spectrometry. The objective of the study is to simultaneously identify abused drugs in 126 decoded urine samples of sexual assault victims by liquid chromatography tandem mass spectrometry. The instrument was operated in multiple-reaction monitoring with an electro-spray positive ionization mode. Chromatograms were separated with ACE5 C18 column on a gradient of acetonitrile. After liquid-liquid extraction, samples were passed through a 0.22μm PVDF filter before injection into the system. The limits of quantitation ranged from 0.2 to 10ng/mL. The precision (CV) results were below 12.9% (intraday) and 15.0% (interday). The intraday accuracy ranged from 84.8 to 121.0%, interday accuracy ranged from 72.0 to 117.3%. We found that 29 (23.0%) were positive for drugs. The most common drug identified is flunitrazepam (11.1%), followed by nimetazepam and ketamine (7.9%), some new psychoactive substances, such as 2C-B, mephedrone, methylone, PMA and PMMA were also identified. We identified abused drugs, benzodiazepines, and new psychoactive substances in urine of sexual assault victims by using liquid chromatography tandem mass spectrometry. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. The Use and Interpretation of Sodium Concentrations in Casual (Spot) Urine Collections for Population Surveillance and Partitioning of Dietary Iodine Intake Sources

    PubMed Central

    Conkle, Joel; van der Haar, Frits

    2016-01-01

    In 2013, the World Health Organization (WHO) called for joint surveillance of population salt and iodine intakes using urinary analysis. 24-h urine collection is considered the gold standard for salt intake assessment, but there is an emerging consensus that casual urine sampling can provide comparable information for population-level surveillance. Our review covers the use of the urinary sodium concentration (UNaC) and the urinary iodine concentration (UIC) from casual urine samples to estimate salt intakes and to partition the sources of iodine intakes. We reviewed literature on 24-h urinary sodium excretion (UNaE) and UNaC and documented the use of UNaC for national salt intake monitoring. We combined information from our review of urinary sodium with evidence on urinary iodine to assess the appropriateness of partitioning methods currently being adapted for cross-sectional survey analyses. At least nine countries are using casual urine collection for surveillance of population salt intakes; all these countries used single samples. Time trend analyses indicate that single UNaC can be used for monitoring changes in mean salt intakes. However; single UNaC suffers the same limitation as single UNaE; i.e., an estimate of the proportion excess salt intake can be biased due to high individual variability. There is evidence, albeit limited, that repeat UNaC sampling has good agreement at the population level with repeat UNaE collections; thus permitting an unbiased estimate of the proportion of excess salt intake. High variability of UIC and UNaC in single urine samples may also bias the estimates of dietary iodine intake sources. Our review concludes that repeated collection, in a sub-sample of individuals, of casual UNaC data would provide an immediate practical approach for routine monitoring of salt intake, because it overcomes the bias in estimates of excess salt intake. Thus we recommend more survey research to expand the evidence-base on predicted-UNaE from repeat casual UNaC sampling. We also conclude that the methodology for partitioning the sources of iodine intake based on the combination of UIC and UNaC measurements in casual urine samples can be improved by repeat collections of casual data; which helps to reduce regression dilution bias. We recommend more survey research to determine the effect of regression dilution bias and circadian rhythms on the partitioning of dietary iodine intake sources. PMID:28025546

  17. Smartphone-based, sensitive µPAD detection of urinary tract infection and gonorrhea.

    PubMed

    Cho, Soohee; Park, Tu San; Nahapetian, Tigran G; Yoon, Jeong-Yeol

    2015-12-15

    The presence of bacteria in urine can be used to monitor the onset or prognosis of urinary tract infection (UTI) and some sexually-transmitted diseases (STDs), such as gonorrhea. Typically, bacteria's presence in urine is confirmed by culturing samples overnight on agar plates, followed by a microscopic examination. Additionally, the presence of Escherichia coli in a urine sample can be indirectly confirmed through assaying for nitrite (generated by reducing nitrate in urine), however this is not sufficiently specific and sensitive. Species/strains identification of bacteria in a urine sample provides insight to appropriate antibiotic treatment options. In this work, a microfluidic paper analytical device (µPAD) was designed and fabricated for evaluating UTI (E. coli) and STD (Neisseria gonorrhoeae) from human urine samples. Anti-E. coli or anti-N. gonorrhoeae antibodies were conjugated to submicron particles then pre-loaded and dried in the center of each paper microfluidic channel. Human urine samples (undiluted) spiked with E. coli or N. gonorrhoeae were incubated for 5 min with 1% Tween 80. The bacteria-spiked urine samples were then introduced to the inlet of paper microfluidic channel, which flowed through the channel by capillary force. Data confirms that proteins were not filtered by μPAD, which is essential for this assay. Urobilin, the component responsible for the yellow appearance of urine and green fluorescence emission, was filtered by μPAD, resulting in significantly minimized false-positive signals. This filtration was simultaneously made during the μPAD assay and no pretreatment/purification step was necessary. Antibody-conjugated particles were immunoagglutinated at the center of the paper channel. The extent of immunoagglutination was quantified by angle-specific Mie scatter under ambient lighting conditions, utilizing a smartphone camera as a detector. The total μPAD assay time was less than 30s. The detection limit was 10 CFU/mL for both E. coli and N. gonorrhoeae, while commercially available gonorrhea rapid kit showed a detection limit of 10(6) CFU/mL. A commercially available nitrite assay test strip also had a detection limit of 10(6) CFU/mL, but this method is not antibody-based and thus not sufficiently specific. By optimizing the particle concentration, we were also able to extend the linear range of the assay up to 10(7) CFU/mL. The proposed prototype will serve as a low-cost, point-of-care, sensitive urinalysis biosensor to monitor UTI and gonorrhea from human urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Vacuum distillation: vapor filtered-catalytic oxidation water reclamation system utilizing radioisotopes

    NASA Technical Reports Server (NTRS)

    Honegger, R. J.; Remus, G. A.; Kurg, E. K.

    1971-01-01

    The development of a functional model water reclamation system is discussed. The system produces potable water by distillation from the urine and respiration-perspiration condensate at the normal rate generated by four men. Basic processes employed are vacuum distillation, vapor filtration, vapor phase catalytic oxidation, and condensation. The system is designed to use four 75-watt isotope heaters for distillation thermal input, and one 45-watt isotope for the catalytic oxidation unit. The system is capable of collecting and storing urine, and provides for stabilizing the urine by chemical pretreatment. The functional model system is designed for operation in a weightless condition with liquid-vapor phase separators for the evaporator still, and centrifugal separators for urine collection and vapor condensation. The system provides for storing and dispensing reclaimed potable water. The system operates in a batch mode for 40 days, with urine residues accumulating in the evaporator. The evaporator still and residue are removed to storage and replaced with a fresh still for the next 40-day period.

  19. Glycosaminoglycan and transforming growth factor beta1 changes in human plasma and urine during the menstrual cycle, in vitro fertilization treatment, and pregnancy.

    PubMed

    De Muro, Pierina; Capobianco, Giampiero; Formato, Marilena; Lepedda, Antonio Junior; Cherchi, Gian Mario; Gordini, Laila; Dessole, Salvatore

    2009-07-01

    To evaluate transforming growth factor beta1 (TGF-beta1) and glycosaminoglycans (GAG) changes in human plasma and urine during the menstrual cycle, IVF-ET, and pregnancy. Prospective clinical study. University hospital. Thirteen women with apparently normal menstrual cycle (group 1); 18 women undergoing IVF-ET (group 2); and 14 low-risk pregnant women (group 3). We assayed plasma and urine concentrations of TGF-beta1, urine content, and distribution of GAG. Blood and urine samples were collected during days 2 to 3, 12 to 13, and 23 to 24 in group 1; in group 2, samples were obtained at menstrual phase, oocyte pick-up day, and 15 days after ET; in group 3, samples were obtained during gestational weeks 10-12, 22-24, and 30-32 and 1 month after delivery. Changes in TGF-beta1 and GAG content. The mean value of total urinary trypsin inhibitor/chondroitin sulfate (UTI/CS) showed a distinct peak at day 12 of the menstrual cycle in the fertile women in whom we monitored the ovulatory period. In the IVF-ET group, GAG distribution and TGF-beta1 levels showed significant differences during the cycle. We observed increased levels of plasma TGF-beta1 15 days after ET. A significant increase of total UTI/CS value with increasing gestation was detected. Transforming growth factor beta1 and GAG levels could represent an additional tool to monitor reproductive events and could be useful, noninvasive markers of ovulation and ongoing pregnancy.

  20. Impact of storage conditions on the urinary metabolomics fingerprint.

    PubMed

    Laparre, Jérôme; Kaabia, Zied; Mooney, Mark; Buckley, Tom; Sherry, Mark; Le Bizec, Bruno; Dervilly-Pinel, Gaud

    2017-01-25

    Urine stability during storage is essential in metabolomics to avoid misleading conclusions or erroneous interpretations. Facing the lack of comprehensive studies on urine metabolome stability, the present work performed a follow-up of potential modifications in urinary chemical profile using LC-HRMS on the basis of two parameters: the storage temperature (+4 °C, -20 °C, -80 °C and freeze-dried stored at -80 °C) and the storage duration (5-144 days). Both HILIC and RP chromatographies have been implemented in order to globally monitor the urinary metabolome. Using an original data processing associated to univariate and multivariate data analysis, our study confirms that chemical profiles of urine samples stored at +4 °C are very rapidly modified, as observed for instance for compounds such as:N-acetyl Glycine, Adenosine, 4-Amino benzoic acid, N-Amino diglycine, creatine, glucuronic acid, 3-hydroxy-benzoic acid, pyridoxal, l-pyroglutamic acid, shikimic acid, succinic acid, thymidine, trigonelline and valeryl-carnitine, while it also demonstrates that urine samples stored at -20 °C exhibit a global stability over a long period with no major modifications compared to -80 °C condition. This study is the first to investigate long term stability of urine samples and report potential modifications in the urinary metabolome, using both targeted approach monitoring individually a large number (n > 200) of urinary metabolites and an untargeted strategy enabling assessing for global impact of storage conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Video Voiding Device for Diagnosing Lower Urinary Tract Dysfunction in Men.

    PubMed

    Shokoueinejad, Mehdi; Alkashgari, Rayan; Mosli, Hisham A; Alothmany, Nazeeh; Levin, Jacob M; Webster, John G

    2017-01-01

    We introduce a novel diagnostic Visual Voiding Device (VVD), which has the ability to visually document urinary voiding events and calculate key voiding parameters such as instantaneous flow rate. The observation of the urinary voiding process along with the instantaneous flow rate can be used to diagnose symptoms of Lower Urinary Tract Dysfunction (LUTD) and improve evaluation of LUTD treatments by providing subsequent follow-up documentations of voiding events after treatments. The VVD enables a patient to have a urinary voiding event in privacy while a urologist monitors, processes, and documents the event from a distance. The VVD consists of two orthogonal cameras which are used to visualize urine leakage from the urethral meatus, urine stream trajectory, and its break-up into droplets. A third, lower back camera monitors a funnel topped cylinder where urine accumulates that contains a floater for accurate readings regardless of the urine color. Software then processes the change in level of accumulating urine in the cylinder and the visual flow properties to calculate urological parameters. Video playback allows for reexamination of the voiding process. The proposed device was tested by integrating a mass flowmeter into the setup and simultaneously measuring the instantaneous flow rate of a predetermined voided volume in order to verify the accuracy of VVD compared to the mass flowmeter. The VVD and mass flowmeter were found to have an accuracy of ±2 and ±3% relative to full scale, respectively. A VVD clinical trial was conducted on 16 healthy male volunteers ages 23-65.

  2. Classification of type 2 diabetes rats based on urine amino acids metabolic profiling by liquid chromatography coupled with tandem mass spectrometry.

    PubMed

    Wang, Chunyan; Zhu, Hongbin; Pi, Zifeng; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2013-09-15

    An analytical method for quantifying underivatized amino acids (AAs) in urine samples of rats was developed by using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Classification of type 2 diabetes rats was based on urine amino acids metabolic profiling. LC-MS/MS analysis was applied through chromatographic separation and multiple reactions monitoring (MRM) transitions of MS/MS. Multivariate profile-wide predictive models were constructed using partial least squares discriminant analysis (PLS-DA) by SIMAC-P 11.5 version software package and hierarchical cluster analysis (HCA) by SPSS 18.0 version software. Some amino acids in urine of rats have significant change. The results of the present study prove that this method could perform the quantification of free AAs in urine of rats by using LC-MS/MS. In summary, the PLS-DA and HCA statistical analysis in our research were preferable to differentiate healthy rats and type 2 diabetes rats by the quantification of AAs in their urine samples. In addition, comparing with health group the seven increased amino acids in urine of type 2 rats were returned to normal under the treatment of acarbose. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Fanconi Syndrome Secondary to Deferasirox in Diamond-Blackfan Anemia: Case Series and Recommendations for Early Diagnosis.

    PubMed

    Papneja, Koyelle; Bhatt, Mihir D; Kirby-Allen, Melanie; Arora, Steven; Wiernikowski, John T; Athale, Uma H

    2016-08-01

    Deferasirox is an oral iron chelator used to treat patients with transfusion-related iron overload. We report, from two institutions, two children with Diamond-Blackfan anemia who developed Fanconi syndrome secondary to deferasirox administration, along with a review of the literature. The current recommendation for the laboratory monitoring of patients receiving deferasirox does not include serum electrolytes or urine analysis. Thus, despite routine clinic visits and bloodwork, these two patients presented with life-threatening electrolyte abnormalities requiring hospitalization. Hence, we propose the inclusion of serum electrolytes and urine analysis as part of routine monitoring to facilitate the early diagnosis of Fanconi syndrome in the context of high doses of deferasirox therapy. © 2016 Wiley Periodicals, Inc.

  4. Plasma, salivary and urinary cortisol levels following physiological and stress doses of hydrocortisone in normal volunteers.

    PubMed

    Jung, Caroline; Greco, Santo; Nguyen, Hanh H T; Ho, Jui T; Lewis, John G; Torpy, David J; Inder, Warrick J

    2014-11-26

    Glucocorticoid replacement is essential in patients with primary and secondary adrenal insufficiency, but many patients remain on higher than recommended dose regimens. There is no uniformly accepted method to monitor the dose in individual patients. We have compared cortisol concentrations in plasma, saliva and urine achieved following "physiological" and "stress" doses of hydrocortisone as potential methods for monitoring glucocorticoid replacement. Cortisol profiles were measured in plasma, saliva and urine following "physiological" (20 mg oral) or "stress" (50 mg intravenous) doses of hydrocortisone in dexamethasone-suppressed healthy subjects (8 in each group), compared to endogenous cortisol levels (12 subjects). Total plasma cortisol was measured half-hourly, and salivary cortisol and urinary cortisol:creatinine ratio were measured hourly from time 0 (between 0830 and 0900) to 5 h. Endogenous plasma corticosteroid-binding globulin (CBG) levels were measured at time 0 and 5 h, and hourly from time 0 to 5 h following administration of oral or intravenous hydrocortisone. Plasma free cortisol was calculated using Coolens' equation. Plasma, salivary and urine cortisol at 2 h after oral hydrocortisone gave a good indication of peak cortisol concentrations, which were uniformly supraphysiological. Intravenous hydrocortisone administration achieved very high 30 minute cortisol concentrations. Total plasma cortisol correlated significantly with both saliva and urine cortisol after oral and intravenous hydrocortisone (P <0.0001, correlation coefficient between 0.61 and 0.94). There was no difference in CBG levels across the sampling period. An oral dose of hydrocortisone 20 mg is supraphysiological for routine maintenance, while stress doses above 50 mg 6-hourly would rarely be necessary in managing acute illness. Salivary cortisol and urinary cortisol:creatinine ratio may provide useful alternatives to plasma cortisol measurements to monitor replacement doses in hypoadrenal patients.

  5. Controlling intake of uranium in the workplace: Applications of biokinetic modeling and occupational monitoring data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard Wayne; Eckerman, Keith F; McGinn, Wilson

    2012-01-01

    This report provides methods for interpreting and applying occupational uranium monitoring data. The methods are based on current international radiation protection guidance, current information on the chemical toxicity of uranium, and best available biokinetic models for uranium. Emphasis is on air monitoring data and three types of bioassay data: the concentration of uranium in urine; the concentration of uranium in feces; and the externally measured content of uranium in the chest. Primary Reference guidance levels for prevention of chemical effects and limitation of radiation effects are selected based on a review of current scientific data and regulatory principles for settingmore » standards. Generic investigation levels and immediate action levels are then defined in terms of these primary guidance levels. The generic investigation and immediate actions levels are stated in terms of radiation dose and concentration of uranium in the kidneys. These are not directly measurable quantities, but models can be used to relate the generic levels to the concentration of uranium in air, urine, or feces, or the total uranium activity in the chest. Default investigation and immediate action levels for uranium in air, urine, feces, and chest are recommended for situations in which there is little information on the form of uranium taken into the body. Methods are prescribed also for deriving case-specific investigation and immediate action levels for uranium in air, urine, feces, and chest when there is sufficient information on the form of uranium to narrow the range of predictions of accumulation of uranium in the main target organs for uranium: kidneys for chemical effects and lungs for radiological effects. In addition, methods for using the information herein for alternative guidance levels, different from the ones selected for this report, are described.« less

  6. Assessment of exposure to polycyclic aromatic hydrocarbons in engine rooms by measurement of urinary 1-hydroxypyrene.

    PubMed Central

    Moen, B E; Nilsson, R; Nordlinder, R; Ovrebø, S; Bleie, K; Skorve, A H; Hollund, B E

    1996-01-01

    OBJECTIVE: Machinists have an increased risk of lung cancer and bladder cancer, and this may be caused by exposure to carcinogenic compounds such as asbestos and polycyclic aromatic hydrocarbons (PAHs) in the engine room. The aim of this study was to investigate the exposure of engine room personnel to PAHs, with 1-hydroxypyrene in urine as a biomarker. METHODS: Urine samples from engine room personnel (n = 51) on 10 ships arriving in different harbours were collected, as well as urine samples from a similar number of unexposed controls (n = 47) on the same ships. Urinary 1-hydroxypyrene was quantitatively measured by high performance liquid chromatography. The exposure to PAHs was estimated by a questionnaire answered by the engine room personnel. On two ships, air monitoring of PAHs in the engine room was performed at sea. Both personal monitoring and area monitoring were performed. The compounds were analysed by gas chromatography of two types (with a flame ionisation detector and with a mass spectrometer). RESULTS: Significantly more 1-hydroxypyrene was found in urine of personnel who had been working in the engine room for the past 24 hours, than in that of the unexposed seamen. The highest concentrations of 1-hydroxypyrene were found among engine room personnel who had experienced oil contamination of the skin during their work in the engine room. Stepwise logistic regression analysis showed a significant relation between the concentrations of 1-hydroxypyrene, smoking, and estimated exposure to PAHs. No PAHs were detected in the air samples. CONCLUSION: Engine room personnel who experience skin exposure to oil and oil products are exposed to PAHs during their work. This indicates that dermal uptake of PAHs is the major route of exposure. PMID:8943834

  7. Fluid therapy LiDCO controlled trial-optimization of volume resuscitation of extensively burned patients through noninvasive continuous real-time hemodynamic monitoring LiDCO.

    PubMed

    Tokarik, Monika; Sjöberg, Folke; Balik, Martin; Pafcuga, Igor; Broz, Ludomir

    2013-01-01

    This pilot trial aims at gaining support for the optimization of acute burn resuscitation through noninvasive continuous real-time hemodynamic monitoring using arterial pulse contour analysis. A group of 21 burned patients meeting preliminary criteria (age range 18-75 years with second- third- degree burns and TBSA ≥10-75%) was randomized during 2010. A hemodynamic monitoring through lithium dilution cardiac output was used in 10 randomized patients (LiDCO group), whereas those without LiDCO monitoring were defined as the control group. The modified Brooke/Parkland formula as a starting resuscitative formula, balanced crystalloids as the initial solutions, urine output of 0.5 ml/kg/hr as a crucial value of adequate intravascular filling were used in both groups. Additionally, the volume and vasopressor/inotropic support were based on dynamic preload parameters in the LiDCO group in the case of circulatory instability and oligouria. Statistical analysis was done using t-tests. Within the first 24 hours postburn, a significantly lower consumption of crystalloids was registered in LiDCO group (P = .04). The fluid balance under LiDCO control in combination with hourly diuresis contributed to reducing the cumulative fluid balance approximately by 10% compared with fluid management based on standard monitoring parameters. The amount of applied solutions in the LiDCO group got closer to Brooke formula whereas the urine output was at the same level in both groups (0.8 ml/kg/hr). The new finding in this study is that when a fluid resuscitation is based on the arterial waveform analysis, the initial fluid volume provided was significantly lower than that delivered on the basis of physician-directed fluid resuscitation (by urine output and mean arterial pressure).

  8. Sanitation practices and perceptions in Kakuma refugee camp, Kenya: Comparing the status quo with a novel service-based approach

    PubMed Central

    Nyoka, Raymond; Foote, Andrew D.; Woods, Emily; Lokey, Hana; O’Reilly, Ciara E.; Magumba, Fred; Okello, Patrick; Mintz, Eric D.; Marano, Nina

    2017-01-01

    Globally, an estimated 2.5 billion people lack access to improved sanitation. Unimproved sanitation increases the risk of morbidity and mortality, especially in protracted refugee situations where sanitation is based on pit latrine use. Once the pit is full, waste remains in the pit, necessitating the construction of a new latrine, straining available land and funding resources. A viable, sustainable solution is needed. This study used qualitative and quantitative methods to design, implement, and pilot a novel sanitation system in Kakuma refugee camp, Kenya. An initial round of 12 pre-implementation focus group discussions (FGDs) were conducted with Dinka and Somali residents to understand sanitation practices, perceptions, and needs. FGDs and a supplementary pre-implementation survey informed the development of an innovative sanitation management system that incorporated the provision of urine and liquid-diverting toilets, which separate urine and fecal waste, and a service-based sanitation system that included weekly waste collection. The new system was implemented on a pilot scale for 6 weeks. During the implementation, bi-weekly surveys were administered in each study household to monitor user perceptions and challenges. At the end of the pilot, the sanitation system was assessed using a second round of four post-implementation FGDs. Those who piloted the new sanitation system reported high levels of user satisfaction. Reported benefits included odor reduction, insect/pest reduction, the sitting design, the appropriateness for special populations, and waste collection. However, urine and liquid diversion presented a challenge for users who perform anal washing and for women who had experienced female genital mutilation. Refugee populations are often culturally and ethnically diverse. Using residents’ input to inform the development of sanitation solutions can increase user acceptability and provide opportunities to improve sanitation system designs based on specific needs. PMID:28704504

  9. Analytical validation applied to simultaneous determination of solvents dichloromethane (DCM), methyl isobutyl ketone (MIBK), tetrahydrofuran (THF) and toluene (TOL) in urine by headspace extraction and injection on chromatographic system with a flame ionization detector

    NASA Astrophysics Data System (ADS)

    Muna, E. D. M.; Pereira, R. P.

    2016-07-01

    The determination of the volatile organic solvents dichloromethane (DCM), methyl isobutyl ketone (MIBK), tetrahydrofuran (THF) and toluene (TOL) is applied on toxicological monitoring of employees in various industrial activities. The gas chromatography technique with flame ionization detector and headspace injection system has been applied. The analytical procedure developed allows the simultaneous determination of the above-mentioned solvents and the accuracy of the method was tested following the INMETRO guidelines through the DOQ-CGRE 008 Rev.04-July/2011.

  10. Integration of Cell Phone Imaging with Microchip ELISA to Detect Ovarian Cancer HE4 Biomarker in Urine at the Point-of-Care

    PubMed Central

    Wang, ShuQi; Zhao, Xiaohu; Khimji, Imran; Akbas, Ragip; Qiu, Weiliang; Edwards, Dale; Cramer, Daniel W.; Ye, Bin; Demirci, Utkan

    2013-01-01

    Ovarian cancer is asymptomatic at early stages and most patients present with advanced levels of disease. Lack of cost-effective methods that can achieve frequent, simple and non-invasive testing hinders early detection and causes high mortality in ovarian cancer patients. Here, we report a simple and inexpensive microchip ELISA-based detection module that employs a portable detection system, i.e., a cell phone/charge-coupled device (CCD) to quantify an ovarian cancer biomarker, HE4, in urine. Integration of a mobile application with a cell phone enabled immediate processing of microchip ELISA results, which eliminated the need for a bulky, expensive spectrophotometer. The HE4 level detected by a cell phone or a lensless CCD system was significantly elevated in urine samples from cancer patients (n = 19) than normal healthy controls (n = 20) (p < 0.001). Receiver operating characteristic (ROC) analyses showed that the microchip ELISA coupled with a cell phone running an automated analysis application had a sensitivity of 89.5% at a specificity of 90%. Under the same specificity, the microchip ELISA coupled with a CCD had a sensitivity of 84.2%. In conclusion, integration of microchip ELISA with cell phone/CCD-based colorimetric measurement technology can be used to detect HE4 biomarker at the point-of-care (POC), paving the way to create bedside technologies for diagnostics and treatment monitoring. PMID:21881677

  11. Human Excretion of Bisphenol A: Blood, Urine, and Sweat (BUS) Study

    PubMed Central

    Genuis, Stephen J.; Beesoon, Sanjay; Birkholz, Detlef; Lobo, Rebecca A.

    2012-01-01

    Background. Bisphenol A (BPA) is an ubiquitous chemical contaminant that has recently been associated with adverse effects on human health. There is incomplete understanding of BPA toxicokinetics, and there are no established interventions to eliminate this compound from the human body. Using 20 study participants, this study was designed to assess the relative concentration of BPA in three body fluids—blood, urine, and sweat—and to determine whether induced sweating may be a therapeutic intervention with potential to facilitate elimination of this compound. Methods. Blood, urine, and sweat were collected from 20 individuals (10 healthy participants and 10 participants with assorted health problems) and analyzed for various environmental toxicants including BPA. Results. BPA was found to differing degrees in each of blood, urine, and sweat. In 16 of 20 participants, BPA was identified in sweat, even in some individuals with no BPA detected in their serum or urine samples. Conclusions. Biomonitoring of BPA through blood and/or urine testing may underestimate the total body burden of this potential toxicant. Sweat analysis should be considered as an additional method for monitoring bioaccumulation of BPA in humans. Induced sweating appears to be a potential method for elimination of BPA. PMID:22253637

  12. Detection and quantification of rituximab in the human urine.

    PubMed

    Jacobs, Roland; Langer-Jacobus, Thais; Duong, Michelle; Stahl, Klaus; Haller, Hermann; Schmidt, Reinhold E; Schiffer, Mario

    2017-12-01

    B cell depletion by rituximab treatment might be inefficient in patients suffering from nephrotic syndrome. Due to the impaired glomerular filtration barrier a significant portion of the therapeutic antibody might be lost into the urinary space. In order to determine the amount of rituximab in the urine of such patients, CD20+ Daudi cells were stained with the patients' urine followed by a fluorochrome-labeled secondary antibody. Mean fluorescence intensity of that way labeled Daudi cells was determined by flow cytometry. Control samples with defined rituximab concentrations were used to create standard curves. The analyses revealed that all nephelometric IgG+ urine samples tested also manifested rituximab at concentrations between 100 and 46,707μg/L. The flow cytometry-based approach is an easy and reliable method to assess rituximab in patients' urine samples for monitoring individual rituximab treatment courses in all patients co-presenting impaired renal filtration. Presence of such antibodies in the urine could be considered as criteria to modify the formulation or modality of rituximab delivery in order to prevent the loss of the therapeutic antibodies and thereby ensuring efficacy of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Excreta Sampling as an Alternative to In Vivo Measurements at the Hanford Site.

    PubMed

    Carbaugh, Eugene H; Antonio, Cheryl L; Lynch, Timothy P

    2015-08-01

    The capabilities of indirect radiobioassay by urine and fecal sample analysis were compared with the direct radiobioassay methods of whole body counting and lung counting for the most common radionuclides and inhalation exposure scenarios encountered by Hanford workers. Radionuclides addressed by in vivo measurement included 137Cs, 60Co, 154Eu, and 241Am as an indicator for plutonium mixtures. The same radionuclides were addressed using gamma energy analysis of urine samples, augmented by radiochemistry and alpha spectrometry methods for plutonium in urine and fecal samples. It was concluded that in vivo whole body counting and lung counting capability should be maintained at the Hanford Site for the foreseeable future, however, urine and fecal sample analysis could provide adequate, though degraded, monitoring capability for workers as a short-term alternative, should in vivo capability be lost due to planned or unplanned circumstances.

  14. Quantitative determination of the hydrolysis products of nitrogen mustards in human urine by liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Lemire, Sharon W; Ashley, David L; Calafat, Antonia M

    2003-01-01

    Nitrogen mustards are a public health concern because of their extreme vesicant properties and the possible exposure of workers during the destruction of chemical stockpiles. A sensitive, rapid, accurate, and precise analysis for the quantitation of ultratrace levels of N-ethyldiethanolamine (EDEA) and N-methyldiethanolamine (MDEA) in human urine as a means of assessing recent exposure to the nitrogen mustards bis(2-chloroethyl)ethylamine and bis(2-chloroethyl)methylamine, respectively, was developed. The method was based on solid-phase extraction, followed by analysis of the urine extract using isotope-dilution high-performance liquid chromatography-mass spectrometry with TurbolonSpray ionization and multiple-reaction monitoring. The method limits of detection were 0.41 ng/mL for EDEA and 0.96 ng/mL for MDEA in 1 mL of urine with coefficients of variation < 10% for both compounds.

  15. Study of removal of ammonia from urine vapor by dual catalyst

    NASA Technical Reports Server (NTRS)

    Budininkas, P.

    1976-01-01

    The feasibility of ammonia removal from urine vapor by a low temperature dual-catalyst system was investigated. The process is based on the initial catalytic oxidation of ammonia present in urine vapor to nitrogen and nitrous oxide, followed by a catalytic decomposition of the nitrous oxide formed into its elements. The most active catalysts for the oxidation of ammonia and for the decomposition of N2O, identified in screening tests, were then combined into dual catalyst systems and tested to establish their overall efficiencies for the removal of ammonia from artificial gas mixtures. Dual catalyst systems capable of ammonia removal from the artificial gas mixtures were then tested with the actual urine vapor produced by boiling untreated urine. A suitable dual catalyst bed arrangement was found that achieved the removal of ammonia and organic carbon, and recovered water of good quality from urine vapor.

  16. The determination of fenspiride in human plasma and urine by liquid chromatography with electrochemical or ultraviolet detection.

    PubMed

    Sauveur, C; Baune, A; Vergnes, N; Jeanniot, J P

    1989-01-01

    A selective and sensitive method for the determination of fenspiride in biological fluids is described. The method involves liquid-liquid extraction followed by separation on a reversed-phase column with electrochemical detection for low levels of the drug in plasma (less than or equal to 100 ng ml-1) or UV absorption for higher concentrations in plasma or urine. The method is suitable for pharmacokinetic analyses and drug monitoring studies.

  17. Biochemical markers of bone turnover in children with clinical bone fragility.

    PubMed

    Bowden, Sasigarn A; Akusoba, Chiazor I; Hayes, John R; Mahan, John D

    2016-06-01

    The role of biochemical bone turnover markers (BTMs) in assessing low bone mass and monitoring bisphosphonate treatment in pediatric patients with clinical bone fragility is not well established. The aim of the study was to examine the correlations of BTMs and the bone mineral density (BMD), and evaluate the effects of bisphosphonates therapy on BTMs in children with clinical bone fragility. Clinical data of 115 patients with clinical bone fragility (mean age 9.7±5.8 years), 102 of whom received bisphosphonates, were studied. Serum alkaline phosphatase (ALP), osteocalcin (OC), urine pyridinoline (PD) and deoxypyridinoline (DPD), BMD at baseline and subsequent years were analyzed. There was a significant negative correlation between urine PD and lumbar BMD (slope=-0.29, p<0.001). There were no correlations between BTMs and lumbar BMD Z-score. There was a significant positive correlation between serum OC and serum ALP, urine PD and DPD (p<0.001). Serum OC, urine PD and DPD index, as expressed as measured value/upper limit of normal value for age, decreased during the first 3 years of bisphosphonate therapy. In children with clinical bone fragility, BTMs correlated with each other, but not with lumbar BMD Z-score. While they were not reliable predictors of degree of low BMD, the bone markers showed suppression during bisphosphonate therapy and may be helpful in monitoring the response to therapy.

  18. Clenbuterol storage stability in the bovine urine and liver samples used for European official control in the azores islands (portugal).

    PubMed

    Pinheiro, Isabel; Jesuino, Bruno; Barbosa, Jorge; Ferreira, Humberto; Ramos, Fernando; Matos, José; da Silveira, Maria Irene Noronha

    2009-02-11

    Clenbuterol is a well-known growth promoter, illegally used in farm animals, especially in cattle. Samples collected for the screening of beta(2)-agonist residues in Portuguese Azores Islands must travel through all the nine islands until they reach Azores Central Laboratory. If any suspicious sample is detected, it must be further transported to the National Reference Laboratory in Lisbon for confirmation. As a consequence of these circumstances, samples are submitted to different transport and storage times, as well as different temperature conditions and in some cases successive freezing and thawing cycles. As clenbuterol is the most detected beta(2)-agonist growth promoter in the Portuguese Residue Monitoring Plan, studies were conducted on the stability of this compound in incurred samples (bovine liver and urine) at +4, -20 and -60 degrees C over time. Samples kept at -20 degrees C were also analyzed over time after successive freezing and thawing cycles. The analyses of clenbuterol over time were performed by gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring (SIM). Clenbuterol in incurred urine and liver samples was significantly stable up to 20 weeks at -20 and -60 degrees C and after, at least, six consecutive freezings and thawings. At +4 degrees C, clenbuterol remained stable, at least until 12 weeks in urine and up to 20 weeks in liver.

  19. Analysis of Urinary Metabolites of Nerve and Blister Chemical Warfare Agents

    DTIC Science & Technology

    2014-08-01

    of CWAs. The analysis methods use UHPLC-MS/MS in Multiple Reaction Monitoring ( MRM ) mode to enhance the selectivity and sensitivity of the method...Chromatography Mass Spectrometry LOD Limit Of Detection LOQ Limit of Quantitation MRM Multiple Reaction Monitoring MSMS Tandem mass...urine [1]. Those analysis methods use UHPLC- MS/MS in Multiple Reaction Monitoring ( MRM ) mode to enhance the selectivity and sensitivity of the method

  20. Bladder urine oxygen tension for assessing renal medullary oxygenation in rabbits: experimental and modeling studies

    PubMed Central

    Sgouralis, Ioannis; Kett, Michelle M.; Ow, Connie P. C.; Abdelkader, Amany; Layton, Anita T.; Gardiner, Bruce S.; Smith, David W.; Lankadeva, Yugeesh R.

    2016-01-01

    Oxygen tension (Po2) of urine in the bladder could be used to monitor risk of acute kidney injury if it varies with medullary Po2. Therefore, we examined this relationship and characterized oxygen diffusion across walls of the ureter and bladder in anesthetized rabbits. A computational model was then developed to predict medullary Po2 from bladder urine Po2. Both intravenous infusion of [Phe2,Ile3,Orn8]-vasopressin and infusion of NG-nitro-l-arginine reduced urinary Po2 and medullary Po2 (8–17%), yet had opposite effects on renal blood flow and urine flow. Changes in bladder urine Po2 during these stimuli correlated strongly with changes in medullary Po2 (within-rabbit r2 = 0.87–0.90). Differences in the Po2 of saline infused into the ureter close to the kidney could be detected in the bladder, although this was diminished at lesser ureteric flow. Diffusion of oxygen across the wall of the bladder was very slow, so it was not considered in the computational model. The model predicts Po2 in the pelvic ureter (presumed to reflect medullary Po2) from known values of bladder urine Po2, urine flow, and arterial Po2. Simulations suggest that, across a physiological range of urine flow in anesthetized rabbits (0.1–0.5 ml/min for a single kidney), a change in bladder urine Po2 explains 10–50% of the change in pelvic urine/medullary Po2. Thus, it is possible to infer changes in medullary Po2 from changes in urinary Po2, so urinary Po2 may have utility as a real-time biomarker of risk of acute kidney injury. PMID:27385734

  1. Urine colorimetry for therapeutic drug monitoring of pyrazinamide during tuberculosis treatment.

    PubMed

    Zentner, Isaac; Modongo, Chawangwa; Zetola, Nicola M; Pasipanodya, Jotam G; Srivastava, Shashikant; Heysell, Scott K; Mpagama, Stellah; Schlect, Hans P; Gumbo, Tawanda; Bisson, Gregory P; Vinnard, Christopher

    2018-03-01

    Pyrazinamide is a key drug in the first-line treatment regimen for tuberculosis, with a potent sterilizing effect. Although low pyrazinamide peak serum concentrations (C max ) are associated with poor treatment outcomes, many resource-constrained settings do not have sufficient laboratory capacity to support therapeutic drug monitoring (TDM). The objective of this study was to determine whether a colorimetric test of urine can identify tuberculosis patients with adequate pyrazinamide exposures, as defined by serum C max above a target threshold. In the derivation study of healthy volunteers, three dose sizes of pyrazinamide were evaluated, and intensive pharmacokinetic blood sampling was performed over an 8-h period, with a timed urine void at 4h post-dosing. Pyrazinamide in urine was isolated by spin column centrifugation with an exchange resin, followed by colorimetric analysis; the absorbance peak at 495nm was measured. The urine assay was then evaluated in a study of 39 HIV/tuberculosis patients in Botswana enrolled in an intensive pharmacokinetic study. Receiver operating characteristics (ROC) curves were used to measure diagnostic accuracy. The guideline-recommended pyrazinamide serum C max target of 35mg/l was evaluated in the primary analysis; this target was found to be predictive of favorable outcomes in a clinical study. Following this, a higher serum C max target of 58mg/l was evaluated in the secondary analysis. At the optimal cut-off identified in the derivation sample, the urine colorimetric assay was 97% sensitive and 50% specific to identify 35 of 39 HIV/tuberculosis patients with pharmacokinetic target attainment, with an area under the ROC curve of 0.81 (95% confidence interval 0.60-0.97). Diagnostic accuracy was lower at the 58mg/l serum C max target, with an area under the ROC curve of 0.68 (95% confidence interval 0.48-0.84). Men were less likely than women to attain either serum pharmacokinetic target. The urine colorimetric assay was sensitive but not specific for the detection of adequate pyrazinamide pharmacokinetic exposures among HIV/tuberculosis patients in a high-burden setting. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Optimizing urine drug testing for monitoring medication compliance in pain management.

    PubMed

    Melanson, Stacy E F; Ptolemy, Adam S; Wasan, Ajay D

    2013-12-01

    It can be challenging to successfully monitor medication compliance in pain management. Clinicians and laboratorians need to collaborate to optimize patient care and maximize operational efficiency. The test menu, assay cutoffs, and testing algorithms utilized in the urine drug testing panels should be periodically reviewed and tailored to the patient population to effectively assess compliance and avoid unnecessary testing and cost to the patient. Pain management and pathology collaborated on an important quality improvement initiative to optimize urine drug testing for monitoring medication compliance in pain management. We retrospectively reviewed 18 months of data from our pain management center. We gathered data on test volumes, positivity rates, and the frequency of false positive results. We also reviewed the clinical utility of our testing algorithms, assay cutoffs, and adulterant panel. In addition, the cost of each component was calculated. The positivity rate for ethanol and 3,4-methylenedioxymethamphetamine were <1% so we eliminated this testing from our panel. We also lowered the screening cutoff for cocaine to meet the clinical needs of the pain management center. In addition, we changed our testing algorithm for 6-acetylmorphine, benzodiazepines, and methadone. For example, due the high rate of false negative results using our immunoassay-based benzodiazepine screen, we removed the screening portion of the algorithm and now perform benzodiazepine confirmation up front in all specimens by liquid chromatography-tandem mass spectrometry. Conducting an interdisciplinary quality improvement project allowed us to optimize our testing panel for monitoring medication compliance in pain management and reduce cost. Wiley Periodicals, Inc.

  3. Comparison of initial stream urine samples and cervical samples for detection of human papillomavirus.

    PubMed

    Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige

    2016-08-01

    Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  4. Back to Basics: Is There a Good Reason to Not Systematically Measure Urine Creatinine in Acute Kidney Injury Monitoring?

    PubMed

    Maciel, Alexandre Toledo

    2016-01-01

    Regardless of the recent advancements in the understanding of the pathophysiology of acute kidney injury (AKI), its diagnosis remains fundamentally dependent on the serum creatinine (sCr) level and urine output (UO), both of which are considered late markers of AKI, offering only a vague idea of the actual creatinine clearance (CrCl). Although not ideal, CrCl is still the most common alternative of the glomerular filtration rate (GFR) in clinical practice. It is generally accepted that early diagnosis of AKI must reveal kidney impairment before sCr increases. Much effort has been made to find tubular and glomerular markers of injury which increase (in blood and/or in urine) before the 'official' diagnosis of AKI. Most of these markers are expensive and not widely available, especially in developing countries. Urine creatinine (CrU), the major link between sCr and UO, has been systematically ignored and clinicians are usually unaware of its value. The reasons for this are unclear, but it may be related to the lack of a reference range, dependence of its concentration value on the urine flow (which in turn is only adequately assessed with an indwelling urinary catheter) and the clinical unavailability of its counterbalance part - creatinine production. Changes in urine tend to precede changes in blood in the course of AKI development and recovery. Hence, it is important to bear in mind that changes in sCr signal renal dysfunction with a significant delay. The search for a more dynamic, 'real-time' but pragmatic assessment of renal function, especially in patients at risk of abrupt decrease in GFR is certainly one of the most relevant focus of research in the field of AKI monitoring. Systematic CrU assessment may be highly relevant in this case. © 2016 S. Karger AG, Basel.

  5. A Safety and Efficacy Study of Tolvaptan Following Open Heart Surgery in 109 Cases.

    PubMed

    Kono, Takanori; Tayama, Eiki; Hori, Hidetsugu; Ueda, Tomohiro; Yamaki, Yuta; Tanaka, Hiroyuki

    2016-07-27

    This study was conducted to evaluate the safety and efficacy of tolvaptan following open heart surgery.We retrospectively reviewed 109 patients who were administered tolvaptan following open heart surgery between August 2011 and July 2014. We divided the patients according to their urine output index (amount of urine output/body surface area) into tertiles as follows: T1 (low responders; n = 36), T2 (intermediate responders; n = 36), and T3 (high responders; n = 37). No fatal adverse events were observed following tolvaptan administration. The factors that showed a significant difference among the 3 groups were body surface area (BSA) and preoperative body weight. Body weight rapidly decreased and a greater increase in the serum sodium level was observed on day 1 in the T3 group than in the other 2 groups. No decrease in blood pressure and no significant differences in the occurrence of atrial fibrillation were observed among the 3 groups during tolvaptan administration.Tolvaptan can be safely and effectively administered to increase the urine output without adversely affecting the cardiovascular system or renal function following open heart surgery. However, careful attention is required regarding the possibility of a rapid increase in the serum sodium level so it is important to monitor changes in serum Na levels.

  6. A quantitative and comprehensive method to analyze human milk oligosaccharide structures in the urine and feces of infants

    PubMed Central

    De Leoz, Maria Lorna A.; Wu, Shuai; Strum, John S.; Niñonuevo, Milady R.; Gaerlan, Stephanie C.; Mirmiran, Majid; German, J. Bruce; Mills, David A.; Lebrilla, Carlito B.; Underwood, Mark A.

    2013-01-01

    Human milk oligosaccharides (HMOs), though non-nutritive to the infant, shape the intestinal microbiota and protect against pathogens during early growth and development. Infant formulas with added galacto-oligosaccharides have been developed to mimic the beneficial effects of HMOs. Premature infants have an immature immune system and a leaky gut and are thus highly susceptible to opportunistic infections. A method employing nanoflow liquid chromatography time-of-flight mass spectrometry (MS) is presented to simultaneously identify and quantify HMOs in the feces and urine of infants, of which 75 HMOs have previously been fully structurally elucidated. Matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance MS was employed for high-resolution and rapid compositional profiling. To demonstrate this novel method, samples from mother-infant dyads as well as samples from infants receiving infant formula fortified with dietary galacto-oligosaccharides or probiotic bifidobacteria were analyzed. Ingested oligosaccharides are demonstrated in high abundance in the infant feces and urine. While the method was developed to examine specimens from preterm infants, it is of general utility and can be used to monitor oligosaccharide consumption and utilization in term infants, children and adults. This method may therefore provide diagnostic and therapeutic opportunities. PMID:23468138

  7. Quantification of chromatographic effects of vitamin B supplementation in urine and implications for hydration assessment.

    PubMed

    Kenefick, Robert W; Heavens, K R; Dennis, W E; Caruso, E M; Guerriere, K I; Charkoudian, N; Cheuvront, S N

    2015-07-15

    Changes in body water elicit reflex adjustments at the kidney, thus maintaining fluid volume homeostasis. These renal adjustments change the concentration and color of urine, variables that can, in turn, be used as biomarkers of hydration status. It has been suggested that vitamin supplementation alters urine color; it is unclear whether any such alteration would confound hydration assessment via colorimetric evaluation. We tested the hypothesis that overnight vitamin B2 and/or B12 supplementation alters urine color as a marker of hydration status. Thirty healthy volunteers were monitored during a 3-day euhydrated baseline, confirmed via first morning nude body mass, urine specific gravity, and urine osmolality. Volunteers then randomly received B2 (n = 10), B12 (n = 10), or B2 + B12 (n = 10) at ∼200 × recommended dietary allowance. Euhydration was verified on trial days (two of the following: body mass ± 1.0% of the mean of visits 1-3, urine specific gravity < 1.02, urine osmolality < 700 mmol/kg). Vitamin purity and urinary B2 concentration ([B2]) and [B12] were quantified via ultraperformance liquid chromatography. Two independent observers assessed urine color using an eight-point standardized color chart. Following supplementation, urinary [B2] was elevated; however, urine color was not different between nonsupplemented and supplemented trials. For example, in the B2 trial, urinary [B2] increased from 8.6 × 10(4) ± 7.7 × 10(4) to 5.7 × 10(6) ± 5.3 × 10(6) nmol/l (P < 0.05), and urine color went from 4 ± 1 to 5 ± 1 (P > 0.05). Both conditions met the euhydrated color classification. We conclude that a large overnight dose of vitamins B2 and B12 does not confound assessment of euhydrated status via urine color. Copyright © 2015 the American Physiological Society.

  8. Noninvasive and Painless Urine Glucose Detection by Using Computer-based Polarimeter

    NASA Astrophysics Data System (ADS)

    Sutrisno; Laksono, Y. A.; Hidayat, N.

    2017-05-01

    Diabetes kills millions of people worldwide each year. It challenges us as researchers to give contribution in early diagnosis to ensure a healthy life. As a matter of fact, common glucose testing devices that have been widely used so far are, at least, glucose meter and urine glucose test strip. The glucose meter ordinarily requires blood taken from patient’s finger. The glucose test strip uses patient’s urine but records unspecific urine glucose level, since the strip only provides the glucose level in some particular ranges. Instead of detecting the glucose level in blood and using the non-specific technique, a noninvasive and painless technique that can detect glucose level accurately will provide a more feasible approach for diabetes diagnosis. The noninvasive and painless urine glucose level monitoring by means of computer-based polarimeter is presented in this paper. The instrument consisted of a power source, a sample box, a light sensor, a polarizer, an analyzer, an analog to digital converter (ADC), and a computer. The concentration of urine glucose concentration was evaluated from the curve of the change in detected optical rotation angle and output potential by the computer-based polarimeter. Statistical analyses by means of Gaussian fitting and linear regression were applied to investigate the rotation angle and urine glucose concentration, respectively. From our experiment, the urine glucose level, measured by glucose test strips, of the normal patient was 100 mg/dl, and the diabetic patient was 500 mg/dl. Our polarimeter even read more precise values for the urine glucose concentrations of those normal and diabetic of the same patients, i.e. 50.61 mg/dl and 502.41 mg/dl, respectively. In other words, the results showed that our polarimeter was able to quantitatively measure the urine glucose level more accurate than urine glucose test strips. Hence, this computer-based polarimeter could be used as an alternative for early detection of urine glucose with noninvasive and painless characteristics.

  9. Monitoring of chromium and nickel in biological fluids of stainless steel welders using the flux-cored-wire (FCW) welding method.

    PubMed

    Stridsklev, Inger Cecilie; Schaller, Karl-Heinz; Langård, Sverre

    2004-11-01

    This study was undertaken to investigate the exposure to chromium (Cr) and nickel (Ni) in flux-cored wire (FCW) welders welding on stainless steel (SS). Seven FCW welders were monitored for 3 days to 1 workweek, measuring Cr and Ni in air, blood, and urine. The welders were questioned about exposure to Cr and Ni during their whole working careers, with emphasis on the week of monitoring, about the use of personal protective equipment and their smoking habits. The air concentrations were mean 200 microg/m(3) (range 2.4-2,744) for total Cr, 11.3 microg/m(3) (<0.2-151.3) for Cr(VI), and 50.4 microg/m(3) (<2.0-416.7) for Ni during the workdays for the five welders who were monitored with air measurements. The levels of Cr and Ni in biological fluids varied between different workplaces. For Cr in whole blood, plasma, and erythrocytes, the mean levels after work were 1.25 (<0.4-8.3) and 1.68 (<0.2-8.0) and 0.9 (<0.4-7.2) microg/l, respectively. For Ni most of the measurements in whole blood and plasma were below the detection limits, the mean levels after work being 0.84 (<0.8-3.3) and 0.57 microg/l (<0.4-1.7), respectively. Mean levels for Cr and Ni in the urine after work were 3.96 (0.34-40.7) and 2.50 (0.56-5.0) microg/g creatinine, respectively. Correlations between the Cr(VI) levels measured in air and the levels of total Cr in the measured biological fluids were found. The results seem to support the view that monitoring of Cr in the urine may be versatile for indirect monitoring of the Cr(VI) air level in FCW welders. The results seem to suggest that external and internal exposure to Cr and Ni in FCW welders welding SS is low in general.

  10. Determination of modafinil in plasma and urine by reversed phase high-performance liquid-chromatography.

    PubMed

    Schwertner, Harvey A; Kong, Suk Bin

    2005-03-09

    Modafinil (Provigil) is a new wake-promoting drug that is being used for the management of excessive sleepiness in patients with narcolepsy. It has pharmacological properties similar to that of amphetamine, but without some of the side effects associated with amphetamine-like stimulants. Since modafinil has the potential to be abused, accurate drug-screening methods are needed for its analysis. In this study, we developed a high-performance liquid-chromatographic procedure (HPLC) for the quantitative analysis of modafinil in plasma and urine. (Phenylthio)acetic acid was used as an internal standard for the analysis of both plasma and urine. Modafinil was extracted from urine and plasma with ethyl acetate and ethyl acetate-acetic acid (100:1, v/v), respectively, and analyzed on a C18 reverse phase column with methanol-water-acetic acid (500:500:1, v/v) as the mobile phase. Recoveries from urine and plasma were 80.0 and 98.9%, respectively and the limit of quantitation was 0.1 microg/mL at 233 nm. Forty-eight 2-h post-dose urine samples from sham controls and from individuals taking 200 or 400 mg of modafinil were analyzed without knowledge of drug administration. All 16-placebo urine samples and all 32 2-h post-dose urine samples were correctly classified. The analytical procedure is accurate and reproducible and can be used for therapeutic drug monitoring, pharmacokinetic studies, and drug abuse screening.

  11. Workplace drug testing in Italy: findings about second-stage testing.

    PubMed

    Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo

    2015-03-01

    Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Multiwalled carbon nanotubes as a sorbent material for the solid phase extraction of lead from urine and subsequent determination by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Peña Crecente, Rosa M.; Lovera, Carlha Gutiérrez; García, Julia Barciela; Méndez, Jennifer Álvarez; Martín, Sagrario García; Latorre, Carlos Herrero

    2014-11-01

    The determination of lead in urine is a way of monitoring the chemical exposure to this metal. In the present paper, a new method for the Pb determination by electrothermal atomic absorption spectrometry (ETAAS) in urine at low levels has been developed. Lead was separated from the undesirable urine matrix by means of a solid phase extraction (SPE) procedure. Oxidized multiwalled carbon nanotubes have been used as a sorbent material. Lead from urine was retained at pH 4.0 and was quantitatively eluted using a 0.7 M nitric acid solution and was subsequently measured by ETAAS. The effects of parameters that influence the adsorption-elution process (such as pH, eluent volume and concentration, sampling and elution flow rates) and the atomic spectrometry conditions have been studied by means of different factorial design strategies. Under the optimized conditions, the detection and quantification limits obtained were 0.08 and 0.26 μg Pb L- 1, respectively. The results demonstrate the absence of a urine matrix effect and this is the consequence of the SPE process carried out. Therefore, the developed method is useful for the analysis of Pb at low levels in real samples without the influence of other urine components. The proposed method was applied to the determination of lead in urine samples of unexposed healthy people and satisfactory results were obtained (in the range 3.64-22.9 μg Pb L- 1).

  13. Study on color difference estimation method of medicine biochemical analysis

    NASA Astrophysics Data System (ADS)

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Sun, Jiashi; Zhou, Fengkun

    2006-01-01

    The biochemical analysis in medicine is an important inspection and diagnosis method in hospital clinic. The biochemical analysis of urine is one important item. The Urine test paper shows corresponding color with different detection project or different illness degree. The color difference between the standard threshold and the test paper color of urine can be used to judge the illness degree, so that further analysis and diagnosis to urine is gotten. The color is a three-dimensional physical variable concerning psychology, while reflectance is one-dimensional variable; therefore, the estimation method of color difference in urine test can have better precision and facility than the conventional test method with one-dimensional reflectance, it can make an accurate diagnose. The digital camera is easy to take an image of urine test paper and is used to carry out the urine biochemical analysis conveniently. On the experiment, the color image of urine test paper is taken by popular color digital camera and saved in the computer which installs a simple color space conversion (RGB -> XYZ -> L *a *b *)and the calculation software. Test sample is graded according to intelligent detection of quantitative color. The images taken every time were saved in computer, and the whole illness process will be monitored. This method can also use in other medicine biochemical analyses that have relation with color. Experiment result shows that this test method is quick and accurate; it can be used in hospital, calibrating organization and family, so its application prospect is extensive.

  14. Determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine with mass selective detection.

    PubMed

    Hughes, D L; Ritter, D J; Wilson, R D

    2001-11-01

    Method development and validation studies have been completed on an assay that will allow the determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. The accurate determination of 2,4-D in urine is an important factor in monitoring worker and population exposure. These studies successfully validated a method for the detection of 2,4-D in urine at a limit of quantitation (LOQ) of 5.00 ppb (parts per billion) using gas chromatography with mass selective detection (GC/MSD). The first study involved the determination of 2,4-D in control human urine and urine samples fortified with 2,4-D. Due to chromatographic interference, a second study was conducted using 14C-2,4-D to verify the recoverability of 2,4-D from human urine at low levels using the GC/MSD method. The second study supports the results of the original data. The 2,4-D was extracted from human urine using a procedure involving hydrolysis using potassium hydroxide, followed by a liquid-liquid extraction into methylene chloride. The extracted samples were derivatized with diazomethane. The methylated fraction was analyzed by GC/MSD. Quantitation was made by comparison to methylated reference standards of 2,4-D. Aliquots fortified at 5-, 50-, and 500-ppb levels were analyzed. The overall mean recovery for all fortified samples was 90.3% with a relative standard deviation of 14.31%.

  15. Surface-enhanced Raman spectroscopy of urine by an ingenious near-infrared Raman spectrometer

    NASA Astrophysics Data System (ADS)

    Feng, Shangyuan; Chen, Weiwei; Li, Yongzeng; Chen, Guannan; Huang, Zufang; Liao, Xiaohua; Xie, Zhiming; Chen, Rong

    2007-11-01

    This paper demonstrates the potential of an elaborately devised near-infrared Raman system in analysis of urine. The broad band in the long-wavelength region of the electronic absorption spectra of the sol with added adsorbent at certain concentrations has been explained in terms of the aggregation of the colloidal silver particles. We have reported the surface-enhanced Raman (SERS) spectra of urine, and studied the silver solution enhanced effects on the urine Raman scattering. The Raman bands of human's urine was assigned to certain molecule vibrations. We have found that different donators have dissimilar SERS of urine in different physiological condition. Comparatively few studies have explored the ability of Raman spectroscopy for the analysis of urine acid. In the present report, we investigated the ability of surface enhanced Raman spectroscopy to measure uric acid in the human urine. The results suggested that the present Raman system holds considerable promise for practical use. Practical applications such as the quantitative medical examination of urine metabolites may also be feasible in the near future.

  16. Design, fabrication and testing of a dual catalyst ammonia removal system for a urine VCD unit

    NASA Technical Reports Server (NTRS)

    Budinikas, P.

    1980-01-01

    A three-man capacity catalytic system for the recovery of water from urine was designed, constructed, and tested, it was designed to operate with feed streams containing high concentrations of urine vapor and only 5 to 7% of oxygen for the oxidation of ammonia and volatile organic vapor.It can operate either in a flow-through or a recycle mode and is capable of accepting the urine vapor produced by a vapor compression distillation evaporator. Testing consisted of short preliminary and optimization test, an endurance test of 74 hours continuous operation, and recycle tests using both air and oxygen. The system was designed for a urine processing rate of 0.86 liters/hr; however, it was tested at rates up to 1.2 liter/hr. Untreated urine evaporated by an electrically heated evaporator was used. The quality of the recovered water meets the U.S. Drinking Water Standards, with the exception of a low pH. Accumulation of solids in the urine sludge is reduced to approximately 65% of the anticipated value.

  17. Direct Analysis of Amphetamine Stimulants in a Whole Urine Sample by Atmospheric Solids Analysis Probe Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Crevelin, Eduardo J.; Salami, Fernanda H.; Alves, Marcela N. R.; De Martinis, Bruno S.; Crotti, Antônio E. M.; Moraes, Luiz A. B.

    2016-05-01

    Amphetamine-type stimulants (ATS) are among illicit stimulant drugs that are most often used worldwide. A major challenge is to develop a fast and efficient methodology involving minimal sample preparation to analyze ATS in biological fluids. In this study, a urine pool solution containing amphetamine, methamphetamine, ephedrine, sibutramine, and fenfluramine at concentrations ranging from 0.5 pg/mL to 100 ng/mL was prepared and analyzed by atmospheric solids analysis probe tandem mass spectrometry (ASAP-MS/MS) and multiple reaction monitoring (MRM). A urine sample and saliva collected from a volunteer contributor (V1) were also analyzed. The limit of detection of the tested compounds ranged between 0.002 and 0.4 ng/mL in urine samples; the signal-to-noise ratio was 5. These results demonstrated that the ASAP-MS/MS methodology is applicable for the fast detection of ATS in urine samples with great sensitivity and specificity, without the need for cleanup, preconcentration, or chromatographic separation. Thus ASAP-MS/MS could potentially be used in clinical and forensic toxicology applications.

  18. Development of analyses by high-performance liquid chromatography and liquid chromatography/tandem mass spectrometry of bilberry (Vaccinium myrtilus) anthocyanins in human plasma and urine.

    PubMed

    Cooke, Darren N; Thomasset, Sarah; Boocock, David J; Schwarz, Michael; Winterhalter, Peter; Steward, William P; Gescher, Andreas J; Marczylo, Timothy H

    2006-09-20

    Anthocyanins are potent antioxidants that may possess chronic disease preventive properties. Here, rapid, reliable, and reproducible solid-phase extraction, high-performance liquid chromatography (HPLC), and mass spectrometry techniques are described for the isolation, separation, and identification of anthocyanins in human plasma and urine. Recoveries of cyanidin-3-glucoside (C3G) were 91% from water, 71% from plasma, and 81% from urine. Intra- and interday variations for C3G extraction were 9 and 9.1% in plasma and 7.1 and 9.1% in urine and were less than 15% for all anthocyanins from a standardized bilberry extract (mirtoselect). Analysis of mirtoselect by HPLC with UV detection produced spectra with 15 peaks compatible with anthocyanin components found in mirtoselect within a total run time of 15 min. Chromatographic analysis of human urine obtained after an oral dose of mirtoselect yielded 19 anthocyanin peaks. Mass spectrometric analysis employing multiple reaction monitoring suggests the presence of unchanged anthocyanins and anthocyanidin glucuronide metabolites.

  19. Microbiological test results using three urine pretreatment regimes with 316L stainless steel

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1993-01-01

    Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.

  20. Extremes of urine osmolality - Lack of effect on red blood cell survival

    NASA Technical Reports Server (NTRS)

    Leon, H. A.; Fleming, J. E.

    1980-01-01

    Rats were allowed a third of normal water intake for 20 days, and food consumption decreased. The reticulocyte count indicated a suppression of erythropoiesis. Urine osmolality increased from 2,000 mosmol/kg to 3,390 mosmol/kg. Random hemolysis and senescence of a cohort of red blood cell (RBC) previously labeled with (2-(C-14)) glycine was monitored via the production of (C-14)O. Neither hemolysis nor senescence was affected. Following water restriction, the polydipsic rats generated a hypotonic urine. Urine osmolality decreased to 1,300 mosmol/kg for at least 6 days; a reticulocytosis occurred, but RBC survival was unaffected. These results contradict those previously reported, which suggest that RBC survival is influenced by the osmotic stress imposed on the RBC by extremes of urine tonicity. This discrepancy, it is concluded, is due to differences in the methods employed for measuring RBC survival. The random-labeling technique employed previously assumes a steady state between RBC production and destruction. The cohort-labeling technique used here measures hemolysis and senescence independent of changes in RBC production, which is known to be depressed by fasting.

  1. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  2. Rapid detection of urinary soluble intercellular adhesion molecule-1 for determination of lupus nephritis activity.

    PubMed

    Wang, Yanyun; Tao, Ye; Liu, Yi; Zhao, Yi; Song, Chao; Zhou, Bin; Wang, Tao; Gao, Linbo; Zhang, Lin; Hu, Huaizhong

    2018-06-01

    The current methods of monitoring the activity of lupus nephritis (LN) may cause unnecessary hospital visits or delayed immunosuppressive therapy. We aimed to find a urinary biomarker that could be developed as a home-based test for monitoring the activity of LN.Urine samples were collected immediately before a renal biopsy from patients of suspected active LN, and also from patients with inactive LN, systemic lupus erythematous without LN or healthy controls. Biomarker search was conducted on a cytokine antibody array and confirmation was done by quantitative evaluation with enzyme-linked immunosorbent assay. The Mann-Whiney test or Student t test was used to compare the levels of 9 cytokines between different groups. The sensitivity and specificity of each cytokine for diagnosis of LN was evaluated by receiver operating characteristic curve. A rapid test based on colloidal gold immunochromatography was then developed for bedside or home use. Furthermore, an experimental e-healthcare system was constructed for recording and sharing the results of the rapid test a cloud-assisted internet of things (IoT) consisting of a sensing device, an IoT device and a cloud server.Adiponectin (Acrp30), soluble intercellular cell adhesion molecule-1 (sICAM-1), neural cell adhesion molecule 1 (NCAM-1), and CD26 were significantly higher in urine samples of active LN patients. sICAM-1 appeared more sensitive and specific among these candidates. When the cut-off value of sICAM-1 was set at 1.44 ng/mL, the sensitivity reached 98.33% with a specificity at 85.71%. The sICAM-1 strip test showed comparable sensitivity of 95% and a specificity of 83.3% for assessing the LN activity. Meanwhile, the e-healthcare system was able to conveniently digitize and share the sICAM-1 rapid test results.sICAM-1 appeared to be an excellent biomarker for monitoring LN activity. The e-healthcare system with cloud-assisted IoT could assist the digitalization and sharing of the bedside or home-based sICAM-1 test results.

  3. GC-MS, LC-MS(n), LC-high resolution-MS(n), and NMR studies on the metabolism and toxicological detection of mesembrine and mesembrenone, the main alkaloids of the legal high "Kanna" isolated from Sceletium tortuosum.

    PubMed

    Meyer, Golo M J; Wink, Carina S D; Zapp, Josef; Maurer, Hans H

    2015-01-01

    Mesembrine and mesembrenone are the main alkaloids of Sceletium tortuosum, a plant species that was used for sedation and analgesia by the KhoiSan, previously known as Hottentots, a tribe in South Africa. After fermentation, the obtained preparation called "Kanna" or "Kougoed" was used by chewing, smoking, or sniffing. Today, Kanna gains popularity by drug users as legal high. For monitoring such consumption, metabolism studies are mandatory because the metabolites are mostly the analytical targets, especially in urine. Therefore, the metabolism of both alkaloids was investigated in rat urine and pooled human liver preparations after several sample work-up procedures. As both alkaloids were not commercially available, they were isolated from plant material by Soxhlet extraction, and their identity confirmed by NMR. The metabolites were identified using gas chromatography-mass spectrometry (GC-MS) and liquid chromatography coupled to linear ion trap high resolution mass spectrometry (LC-HR-MS(n)). Both alkaloids were O- and N-demethylated, dihydrated, and/or hydroxylated at different positions. The phenolic metabolites were partly excreted as glucuronides and/or sulfates. Most of the phase I metabolites identified in rat urine could be detected also in the human liver preparations. After a common user's low dose application of mesembrine, mainly the O- and N demethyl-dihydro, hydroxy, and bis-demethyl-dihydro metabolites, and in case of mesembrenone only the N-demethyl and the N-demethyl-dihydro metabolite could be detected in rat urine using the authors' standard urine screening approaches (SUSA) by GC-MS or LC-MS(n). Thus, it should be possible to monitor a consumption of mesembrine and/or mesembrenone assuming similar pharmacokinetics in humans.

  4. Estimating occupational exposure to the pyrethroid termiticide bifenthrin by measuring metabolites in urine.

    PubMed

    Smith, P A; Thompson, M J; Edwards, J W

    2002-10-05

    The control of subterranean termites in Australia is predominantly through the application of chemical barriers in the soil beneath and surrounding buildings. The chemicals used to repel or kill termites are the organophosphorus insecticide, chlorpyrifos, and the synthetic pyrethroid, bifenthrin. These are applied through surface sprays and subfloor injection by licensed pest control operators. To determine the exposure of these personnel to these pesticides it is most usual to measure airborne concentrations or dermal deposition rates. However, to support information obtained from these methods it is often appropriate to determine the amount of the chemicals absorbed, using biological monitoring techniques including measurement of the chemicals or their metabolites in urine. While there are effective techniques for the monitoring of chlorpyrifos exposure by measuring either the alkyl phosphate or trichloropyridinol metabolites, there have been no published reports of suitable methods to measure bifenthrin metabolites in urine. This paper describes an extraction and HPLC-UV method used to simultaneously measure the urinary excretion of 2-methyl-3-phenylbenzoic acid (MPA), a metabolite of bifenthrin, and 3-phenoxybenzoic acid (PBA), a metabolite of several other common pyrethroid insecticides, with a detection limit for each of 2.5 ng/ml. The paper also describes the pilot application of this method to a study of South Australian pest control operators handling bifenthrin. MPA ranged from 1.8 to 31.9 microg/g creatinine and PBA from 1.3 to 30.0 microg/g in the urine of pest control workers. MPA was detected in urine of control workers without bifenthrin exposure only at low levels (1.0-1.4 microg/g creatinine), but PBA was found in both at higher levels (1.2-61.1 microg/g creatinine). Copyright 2002 Elsevier Science B.V.

  5. Urine colorimetry to detect Low rifampin exposure during tuberculosis therapy: a proof-of-concept study.

    PubMed

    Zentner, Isaac; Schlecht, Hans P; Khensouvann, Lorna; Tamuhla, Neo; Kutzler, Michele; Ivaturi, Vijay; Pasipanodya, Jotam G; Gumbo, Tawanda; Peloquin, Charles A; Bisson, Gregory P; Vinnard, Christopher

    2016-06-01

    The cost and complexity of current approaches to therapeutic drug monitoring during tuberculosis (TB) therapy limits widespread use in areas of greatest need. We sought to determine whether urine colorimetry could have a novel application as a form of therapeutic drug monitoring during anti-TB therapy. Among healthy volunteers, we evaluated 3 dose sizes of rifampin (150 mg, 300 mg, and 600 mg), performed intensive pharmacokinetic sampling, and collected a timed urine void at 4 h post-dosing. The absorbance peak at 475 nm was measured after rifamycin extraction. The optimal cutoff was evaluated in a study of 39 HIV/TB patients undergoing TB treatment in Botswana. In the derivation study, a urine colorimetric assay value of 4.0 × 10(-2) Abs, using a timed void 4 h after dosing, demonstrated a sensitivity of 92 % and specificity of 60 % to detect a peak rifampin concentration (Cmax) under 8 mg/L, with an area under the ROC curve of 0.92. In the validation study, this cutoff was specific (100 %) but insensitive (28 %). We observed similar test characteristics for a target Cmax target of 6.6 mg/L, and a target area under the drug concentration-versus-time curve (AUC0-8) target of 24.1 mg•hour/L. The urine colorimetric assay was specific but insensitive to detect low rifampin serum concentrations among HIV/TB patients. In future work we will attempt to optimize sampling times and assay performance, with the goal of delivering a method that can translate into a point-of-care assessment of rifampin exposure during anti-TB therapy.

  6. Vitreous Fluid and/or Urine Glucose Concentrations in 1,335 Civil Aviation Accident Pilot Fatalities

    DTIC Science & Technology

    2008-05-01

    glucose, and in those cases wherein glucose levels are elevated, blood hemoglobin A1c ( HbA1c ) is measured. These analyses are conducted to monitor...diabetes. In this study, the prevalence of elevated glucose concentrations in fatally injured civilian pilots is evaluated. Glucose and HbA1c are measured...whom samples were received during 1998–2005 and whose vitreous fluid and/or urine glucose concentrations were measured. HbA1c levels and information

  7. Removal of ammonia from urine vapor by a dual-catalyst system

    NASA Technical Reports Server (NTRS)

    Budininkas, P.

    1977-01-01

    The feasibility of removing ammonia from urine vapor by a low-temperature dual-catalyst system has been demonstrated. The process is based on the catalytic oxidation of ammonia to a mixture of nitrogen, nitrous oxide, and water, followed by a catalytic decomposition of the nitrous oxide into its elements. Potential ammonia oxidation and nitrous oxide decomposition catalysts were first screened with artificial gas mixtures, then tested with the actual urine vapor produced by boiling untreated urine. A suitable dual-catalyst bed arrangement was found that achieved the removal of ammonia and also organic carbon, and recovered water of good quality from urine vapor.

  8. Chemical Method of Urine Volume Measurement

    NASA Technical Reports Server (NTRS)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  9. Activation of the Endogenous Renin-Angiotensin-Aldosterone System or Aldosterone Administration Increases Urinary Exosomal Sodium Channel Excretion.

    PubMed

    Qi, Ying; Wang, Xiaojing; Rose, Kristie L; MacDonald, W Hayes; Zhang, Bing; Schey, Kevin L; Luther, James M

    2016-02-01

    Urinary exosomes secreted by multiple cell types in the kidney may participate in intercellular signaling and provide an enriched source of kidney-specific proteins for biomarker discovery. Factors that alter the exosomal protein content remain unknown. To determine whether endogenous and exogenous hormones modify urinary exosomal protein content, we analyzed samples from 14 mildly hypertensive patients in a crossover study during a high-sodium (HS, 160 mmol/d) diet and low-sodium (LS, 20 mmol/d) diet to activate the endogenous renin-angiotensin-aldosterone system. We further analyzed selected exosomal protein content in a separate cohort of healthy persons receiving intravenous aldosterone (0.7 μg/kg per hour for 10 hours) versus vehicle infusion. The LS diet increased plasma renin activity and aldosterone concentration, whereas aldosterone infusion increased only aldosterone concentration. Protein analysis of paired urine exosome samples by liquid chromatography-tandem mass spectrometry-based multidimensional protein identification technology detected 2775 unique proteins, of which 316 exhibited significantly altered abundance during LS diet. Sodium chloride cotransporter (NCC) and α- and γ-epithelial sodium channel (ENaC) subunits from the discovery set were verified using targeted multiple reaction monitoring mass spectrometry quantified with isotope-labeled peptide standards. Dietary sodium restriction or acute aldosterone infusion similarly increased urine exosomal γENaC[112-122] peptide concentrations nearly 20-fold, which correlated with plasma aldosterone concentration and urinary Na/K ratio. Urine exosomal NCC and αENaC concentrations were relatively unchanged during these interventions. We conclude that urinary exosome content is altered by renin-angiotensin-aldosterone system activation. Urinary measurement of exosomal γENaC[112-122] concentration may provide a useful biomarker of ENaC activation in future clinical studies. Copyright © 2016 by the American Society of Nephrology.

  10. Activation of the Endogenous Renin-Angiotensin-Aldosterone System or Aldosterone Administration Increases Urinary Exosomal Sodium Channel Excretion

    PubMed Central

    Qi, Ying; Wang, Xiaojing; Rose, Kristie L.; MacDonald, W. Hayes; Zhang, Bing; Schey, Kevin L.

    2016-01-01

    Urinary exosomes secreted by multiple cell types in the kidney may participate in intercellular signaling and provide an enriched source of kidney-specific proteins for biomarker discovery. Factors that alter the exosomal protein content remain unknown. To determine whether endogenous and exogenous hormones modify urinary exosomal protein content, we analyzed samples from 14 mildly hypertensive patients in a crossover study during a high-sodium (HS, 160 mmol/d) diet and low-sodium (LS, 20 mmol/d) diet to activate the endogenous renin-angiotensin-aldosterone system. We further analyzed selected exosomal protein content in a separate cohort of healthy persons receiving intravenous aldosterone (0.7 μg/kg per hour for 10 hours) versus vehicle infusion. The LS diet increased plasma renin activity and aldosterone concentration, whereas aldosterone infusion increased only aldosterone concentration. Protein analysis of paired urine exosome samples by liquid chromatography-tandem mass spectrometry–based multidimensional protein identification technology detected 2775 unique proteins, of which 316 exhibited significantly altered abundance during LS diet. Sodium chloride cotransporter (NCC) and α- and γ-epithelial sodium channel (ENaC) subunits from the discovery set were verified using targeted multiple reaction monitoring mass spectrometry quantified with isotope-labeled peptide standards. Dietary sodium restriction or acute aldosterone infusion similarly increased urine exosomal γENaC[112–122] peptide concentrations nearly 20-fold, which correlated with plasma aldosterone concentration and urinary Na/K ratio. Urine exosomal NCC and αENaC concentrations were relatively unchanged during these interventions. We conclude that urinary exosome content is altered by renin-angiotensin-aldosterone system activation. Urinary measurement of exosomal γENaC[112–122] concentration may provide a useful biomarker of ENaC activation in future clinical studies. PMID:26113616

  11. An analysis of workers' tritium concentration in urine samples as a function of time after intake at Korean pressurised heavy water reactors.

    PubMed

    Kim, Hee Geun; Kong, Tae Young

    2012-12-01

    In general, internal exposure from tritium at pressurised heavy water reactors (PHWRs) accounts for ∼20-40 % of the total radiation dose. Tritium usually reaches the equilibrium concentration after a few hours inside the body and is then excreted from the body with an effective half-life in the order of 10 d. In this study, tritium metabolism was reviewed using its excretion rate in urine samples of workers at Korean PHWRs. The tritium concentration in workers' urine samples was also measured as a function of time after intake. On the basis of the monitoring results, changes in the tritium concentration inside the body were then analysed.

  12. Urine drug screen

    MedlinePlus

    Drug screen - urine ... detect the presence of illegal and some prescription drugs in your urine. Their presence may indicate that you recently used these drugs. Some drugs may remain in your system for ...

  13. A urine volume measurement system

    NASA Technical Reports Server (NTRS)

    Poppendiek, H. F.; Mouritzen, G.; Sabin, C. M.

    1972-01-01

    An improved urine volume measurement system for use in the unusual environment of manned space flight is reported. The system utilizes a low time-constant thermal flowmeter. The time integral of the transient response of the flowmeter gives the urine volume during a void as it occurs. In addition, the two phase flows through the flowmeter present no problem. Developments of the thermal flowmeter and a verification of the predicted performance characteristics are summarized.

  14. Monitoring benzo(a)pyrene exposure using laser-excited Shpol'skii spectroscopy of benzo(a)pyrene metabolites

    NASA Astrophysics Data System (ADS)

    Ariese, Freek; Kok, S. J.; Verkaik, M.; Hoornweg, Gerard P.; Gooijer, Cees; Velthorst, Nel H.; Hofstraat, Johannes W.

    1993-03-01

    Exposure to polycyclic aromatic hydrocarbons (PAHs) is considered a serious threat to the health of animals and humans and should be thoroughly monitored. Next to chemical analysis of PAHs in the various environmental compartments, PAH metabolites in body fluids (e.g., bile and urine) could be measured to determine the actual uptake. Although pyrene is not considered particularly toxic, its metabolite 1-hydroxy pyrene is often used as a biomarker because it is usually found at considerable concentrations and the analysis is relatively simple. As the result of differences in volatility and/or solubility, the uptake of more relevant carcinogens like benzo(a)pyrene may be some orders of magnitude lower and is far more difficult to measure. Determination of benzo(a)pyrene metabolites requires a very selective and sensitive method, and so far these compounds could only be detected after exposure to heavy pollution. In this paper it will be shown how several hydroxy benzo(a)pyrene metabolites are selectively determined using Shpol'skii spectroscopy. With this method, highly resolved fluorescence spectra are obtained upon cooling the sample in a suitable solvent to cryogenic temperatures. When a tunable laser system is employed as an excitation source, sub- femtomole amounts can be detected. Applications of the technique to marine monitoring (benzo(a)pyrene metabolites in fish bile) and to occupational hygienics (benzo(a)pyrene metabolites in workers' urine) are discussed. The data will be compared with 1-hydroxy pyrene concentrations to evaluate the routine use of the latter compound as a biomarker.

  15. Lessons Learned for the Assessment of Children’s Pesticide Exposure: Critical Sampling and Analytical Issues for Future Studies

    PubMed Central

    Fenske, Richard A.; Bradman, Asa; Whyatt, Robin M.; Wolff, Mary S.; Barr, Dana B.

    2005-01-01

    In this article we examine sampling strategies and analytical methods used in a series of recent studies of children’s exposure to pesticides that may prove useful in the design and implementation of the National Children’s Study. We focus primarily on the experiences of four of the National Institute of Environmental Health Sciences/U.S. Environmental Protection Agency/ Children’s Centers and include University of Washington studies that predated these centers. These studies have measured maternal exposures, perinatal exposures, infant and toddler exposures, and exposure among young children through biologic monitoring, personal sampling, and environmental monitoring. Biologic monitoring appears to be the best available method for assessment of children’s exposure to pesticides, with some limitations. It is likely that a combination of biomarkers, environmental measurements, and questionnaires will be needed after careful consideration of the specific hypotheses posed by investigators and the limitations of each exposure metric. The value of environmental measurements, such as surface and toy wipes and indoor air or house dust samples, deserves further investigation. Emphasis on personal rather than environmental sampling in conjunction with urine or blood sampling is likely to be most effective at classifying exposure. For infants and young children, ease of urine collection (possible for extended periods of time) may make these samples the best available approach to capturing exposure variability of nonpersistent pesticides; additional validation studies are needed. Saliva measurements of pesticides, if feasible, would overcome the limitations of urinary metabolite-based exposure analysis. Global positioning system technology appears promising in the delineation of children’s time–location patterns. PMID:16203262

  16. Progress on the biomarkers for tuberculosis diagnosis.

    PubMed

    Fu, Tiwei; Xie, Jianping

    2011-01-01

    Tuberculosis (TB) remains a major threat to global health. Biomarkers derived from pathogen-host interaction can facilitate the monitoring of active TB. The recent progress regarding such biomarkers is summarized, including those can be used from serum, sputum, urine, or breath monitoring. A wide range of potential biomarkers such as protein antigens, cell-free nucleic acids, and lipoarabinomannose were compiled. The possible use of biomarkers for infection identification and monitoring drug efficacy are also presented.

  17. Rapid detection and identification of N-acetyl-L-cysteine thioethers using constant neutral loss and theoretical multiple reaction monitoring combined with enhanced product-ion scans on a linear ion trap mass spectrometer.

    PubMed

    Scholz, Karoline; Dekant, Wolfgang; Völkel, Wolfgang; Pähler, Axel

    2005-12-01

    A sensitive and specific liquid chromatography-mass spectrometry (LC-MS) method based on the combination of constant neutral loss scans (CNL) with product ion scans was developed on a linear ion trap. The method is applicable for the detection and identification of analytes with identical chemical substructures (such as conjugates of xenobiotics formed in biological systems) which give common CNLs. A specific CNL was observed for thioethers of N-acetyl-L-cysteine (mercapturic acids, MA) by LC-MS/MS. MS and HPLC parameters were optimized with 16 MAs available as reference compounds. All of these provided a CNL of 129 Da in the negative-ion mode. To assess sensitivity, a multiple reaction monitoring (MRM) mode with 251 theoretical transitions using the CNL of 129 Da combined with a product ion scan (IDA thMRM) was compared with CNL combined with a product ion scan (IDA CNL). An information-dependent acquisition (IDA) uses a survey scan such as MRM (multiple reaction monitoring) to generate "informations" and starting a second acquisition experiment such as a product ion scan using these "informations." Th-MRM means calculated transitions and not transitions generated from an available standard in the tuning mode. The product ion spectra provide additional information on the chemical structure of the unknown analytes. All MA standards were spiked in low concentrations to rat urines and were detected with both methods with LODs ranging from 60 pmol/mL to 1.63 nmol/mL with IDA thMRM. The expected product ion spectra were observed in urine. Application of this screening method to biological samples indicated the presence of a number of MAs in urine of unexposed rats, and resulted in the identification of 1,4-dihydroxynonene mercapturic acid as one of these MAs by negative and positive product ion spectra. These results show that the developed methods have a high potential to serve as both a prescreen to detect unknown MAs and to identify these analytes in complex matrix.

  18. Urine Concentration and Pyuria for Identifying UTI in Infants.

    PubMed

    Chaudhari, Pradip P; Monuteaux, Michael C; Bachur, Richard G

    2016-11-01

    Varying urine white blood cell (WBC) thresholds have been recommended for the presumptive diagnosis of urinary tract infection (UTI) among young infants. These thresholds have not been studied with newer automated urinalysis systems that analyze uncentrifuged urine that might be influenced by urine concentration. Our objective was to determine the optimal urine WBC threshold for UTI in young infants by using an automated urinalysis system, stratified by urine concentration. Retrospective cross-sectional study of infants aged <3 months evaluated for UTI in the emergency department with paired urinalysis and urine culture. UTI was defined as ≥50 000 colony-forming units/mL from catheterized specimens. Test characteristics were calculated across a range of WBC and leukocyte esterase (LE) cut-points, dichotomized into specific gravity groups (dilute <1.015; concentrated ≥1.015). Twenty-seven thousand infants with a median age of 1.7 months were studied. UTI prevalence was 7.8%. Optimal WBC cut-points were 3 WBC/high-power field (HPF) in dilute urine (likelihood ratio positive [LR+] 9.9, likelihood ratio negative [LR‒] 0.15) and 6 WBC/HPF (LR+ 10.1, LR‒ 0.17) in concentrated urine. For dipstick analysis, positive LE has excellent test characteristics regardless of urine concentration (LR+ 22.1, LR‒ 0.12 in dilute urine; LR+ 31.6, LR‒ 0.22 in concentrated urine). Urine concentration should be incorporated into the interpretation of automated microscopic urinalysis in young infants. Pyuria thresholds of 3 WBC/HPF in dilute urine and 6 WBC/HPF in concentrated urine are recommended for the presumptive diagnosis of UTI. Without correction of specific gravity, positive LE by automated dipstick is a reliably strong indicator of UTI. Copyright © 2016 by the American Academy of Pediatrics.

  19. Identification and quantification of (5'R)- and (5'S)-8,5'-cyclo-2'-deoxyadenosines in human urine as putative biomarkers of oxidatively induced damage to DNA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaruga, Pawel, E-mail: pawel.jaruga@nist.gov; Department of Clinical Biochemistry, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz; Dizdaroglu, Miral

    2010-06-18

    Biomarkers of oxidatively induced DNA damage are of great interest and can potentially be used for the early detection of disease, monitoring the progression of disease and determining the efficacy of therapy. The present work deals with the measurement in human urine of (5'R)-8,5'-cyclo-2'-deoxyadenosine (R-cdA) and (5'S)-8,5'-cyclo-2'-deoxyadenosine (S-cdA). These modified nucleosides had hitherto not been considered or investigated to be present in urine as possible biomarkers of oxidatively induced DNA damage. Urine samples were collected from volunteers, purified and analyzed by LC-MS/MS with isotope-dilution. R-cdA and S-cdA were detected in urine and quantified. Creatinine levels were also measured. In addition,more » we measured 8-hydroxy-2'-deoxyguanosine that is commonly used as a biomarker. This study shows, for the first time, that R-cdA and S-cdA exist in human urine and can be identified and quantified by LC-MS/MS. We propose that R-cdA and S-cdA may be well-suited biomarkers for disease processes such as carcinogenesis.« less

  20. Challenges for Detecting Valproic Acid in a Nontargeted Urine Drug Screening Method.

    PubMed

    Pope, Jeffrey D; Black, Marion J; Drummer, Olaf H; Schneider, Hans G

    2017-08-01

    Valproic acid (VPA) is a widely prescribed medicine, and acute toxicity is possible. As such, it should be included in any nontargeted urine drug screening method. In many published liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) methods, VPA is usually measured using a pseudo-multiple reaction monitoring (MRM) transition. We investigate a simple ultra-high-performance liquid chromatography-quadrupole time-of-flight (QTof) approach to detect the presence of VPA with more confidence. Three commercially sourced VPA metabolites were characterized and added to a nontargeted high-resolution MS urine drug screening method. All analyses were performed on a Waters Xevo G2-XS LC-QTof in negative electrospray ionization mode. The mass detector was operated in MS mode, and data were processed with UNIFI software. Sixty-eight patient urine samples, which were previously identified by a well-established gas chromatography-MS method as containing VPA, were analyzed on the Waters Xevo G2-XS LC-QTof, to validate this approach. VPA metabolite standards were characterized, and their detection data were added to the broad drug screening library. VPA metabolites were readily detectable in the urine of patients taking VPA. The inclusion of characterized VPA metabolites provides a simple and reliable method enabling the detection of VPA in nontargeted urine drug screening.

  1. Perturbations in the Urinary Exosome in Transplant Rejection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigdel, Tara K.; NG, Yolanda; Lee, Sangho

    Background: Urine exosomes, vesicles exocytosed into urine by all renal epithelial cell types, occur under normal physiologic and disease states. Exosome contents may mirror disease-specific proteome perturbations in kidney injury. Analysis methodologies for the exosomal fraction of the urinary proteome were developed and for comparing the urinary exosomal fraction versus unfractionated proteome for biomarker discovery. Methods: Urine exosomes were isolated by centrifugal filtration from mid-stream, second morning void, urine samples collected from kidney transplant recipients with and without biopsy matched acute rejection. The proteomes of unfractionated whole urine (Uw) and urine exosomes (Uexo) underwent mass spectrometry-based quantitative proteomics analysis. Themore » proteome data were analyzed for significant differential protein abundances in acute rejection (AR). Results: Identifications of 1018 and 349 proteins, Uw and Uexo fractions, respectively, demonstrated a 279 protein overlap between the two urinary compartments with 25%(70) of overlapping proteins unique to Uexoand represented membrane bound proteins (p=9.31e-7). Of 349 urine exosomal proteins identified in transplant patients 220 were not previously identified in the normal urine exosomal fraction. Uexo proteins (11), functioning in the inflammatory / stress response, were more abundant in patients with biopsy-confirmed acute rejection, 3 of which were exclusive to Uexo. Uexo AR-specific biomarkers (8) were also detected in Uw, but since they were observed at significantly lower abundances in Uw, they were not significant for AR in Uw. Conclusions: A rapid urinary exosome isolation method and quantitative measurement of enriched Uexo proteins was applied. Urine proteins specific to the exosomal fraction were detected either in unfractionated urine (at low abundances) or by Uexo fraction analysis. Perturbed proteins in the exosomal compartment of urine collected from kidney transplant patients were specific to inflammatory responses, and were not observed in the Uexo fraction from normal healthy subjects. Uexo specific protein alterations in renal disease provide potential mechanistic insights and offer a unique panel of sensitive biomarkers for monitoring for acute transplant rejection.« less

  2. Elimination kinetics of metals after an accidental exposure to welding fumes.

    PubMed

    Schaller, Karl H; Csanady, György; Filser, Johannes; Jüngert, Barbara; Drexler, Hans

    2007-07-01

    We had the opportunity to study the kinetics of metals in blood and urine samples of a flame-sprayer exposed to high accident-prone workplace exposure. We measured over 1 year, the nickel, aluminium, and chromium concentrations in blood and urine specimens after exposure. On this basis, we evaluated the corresponding half-lives. Blood and urine sampling were carried out five times after accidental exposure over a period of 1 year. The metals were analysed by graphite furnace atomic absorption spectrometry and Zeeman compensation with reliable methods. Either a mono-exponential or a bi-exponential function was fitted to the concentration-time courses of selected metals using weighted least squares non-linear regression analysis. The amount excreted in urine was calculated integrating the urinary decay curve and multiplying with the daily creatinine excretion. The first examination was carried out 15 days after exposure. The mean aluminium concentration in plasma was 8.2 microg/l and in urine, 58.4 microg/g creatinine. The mean nickel concentration in blood was 59.6 microg/l and the excretion in urine 700 microg/g creatinine. The mean chromium level in blood was 1.4 microg/l in urine, 7.4 microg/g creatinine. For the three elements, the metal concentrations in blood and urine exceeded the reference values at least in the initial phase. For nickel, the German biological threshold limit values (EKA) were exceeded. Aluminium showed a mono-exponential decay, whereas the elimination of chromium and nickel was biphasic in biological fluids of the accidentally exposed welder. The half-lives were as follows: for aluminium 140 days (urine) and 160 days (plasma); for chromium 40 and 730 days (urine); for nickel 25 and 610 days (urine) as well as 30 and 240 days (blood). The renal clearance of aluminium and nickel was about 2 l/h estimated for the last monitoring day.

  3. Biologically Pre-Treated Habitation Waste Water as a Sustainable Green Urine Pre-Treat Solution

    NASA Technical Reports Server (NTRS)

    Jackson, W. Andrew; Thompson, Bret; Sevanthi, Ritesh; Morse, Audra; Meyer, Caitlin; Callahan, Michael

    2017-01-01

    The ability to recover water from urine and flush water is a critical process to allow long term sustainable human habitation in space or bases on the moon or mars. Organic N present as urea or similar compounds can hydrolyze producing free ammonia. This reaction results in an increase in the pH converting ammonium to ammonia which is volatile and not removed by distillation. The increase in pH will also cause precipitation reactions to occur. In order to prevent this, urine on ISS is combined with a pretreat solution. While use of a pretreatment solution has been successful, there are numerous draw backs including: storage and use of highly hazardous solutions, limitations on water recovery (less than 85%), and production of brine with pore dewatering characteristics. We evaluated the use of biologically treated habitation wastewaters (ISS and early planetary base) to replace the current pretreat solution. We evaluated both amended and un-amended bioreactor effluent. For the amended effluent, we evaluated "green" pretreat chemicals including citric acid and citric acid amended with benzoic acid. We used a mock urine/air separator modeled after the urine collection assembly on ISS. The urine/air separator was challenged continually for >6 months. Depending on the test point, the separator was challenged daily with donated urine and flushed with amended or un-amended reactor effluent. We monitored the pH of the urine, flush solution and residual pH in the urine/air separator after each urine event. We also evaluated solids production and biological growth. Our results support the use of both un-amended and amended bioreactor effluent to maintain the operability of the urine /air separator. The ability to use bioreactor effluent could decrease consumable cost, reduce hazards associated with current pre-treat chemicals, allow other membrane based desalination processes to be utilized, and improve brine characteristics.

  4. Occupational exposure to airborne mercury during gold mining operations near El Callao, Venezuela.

    PubMed

    Drake, P L; Rojas, M; Reh, C M; Mueller, C A; Jenkins, F M

    2001-04-01

    The National Institute for Occupational Safety and Health (NIOSH) recently conducted a cross-sectional study during gold mining operations near El Callao, Venezuela. The purpose of the study was to assess mercury exposures and mercury-related microdamage to the kidneys. The study consisted of concurrent occupational hygiene and biological monitoring, and an examination of the processing techniques employed at the different mining facilities. Mercury was used in these facilities to remove gold by forming a mercury-gold amalgam. The gold was purified either by heating the amalgam in the open with a propane torch or by using a small retort. Thirty-eight workers participated in this study. Some participants were employed by a large mining company, while others were considered "informal miners" (self-employed). Mercury exposure was monitored by sampling air from the workers' breathing zones. These full-shift air samples were used to calculate time-weighted average (TWA) mercury exposure concentrations. A questionnaire was administered and a spot urine sample was collected. Each urine sample was analyzed for mercury, creatinine, and N-acetyl-beta-D-glucosaminidase (NAG). The range for the 8-h TWA airborne mercury exposure concentrations was 0.1 to 6,315 micrograms/m3, with a mean of 183 micrograms/m3. Twenty percent of the TWA airborne mercury exposure measurements were above the NIOSH recommended exposure limit (REL) of 50 micrograms/m3, and 26% exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) of 25 micrograms/m3. The mean urine mercury concentration was 101 micrograms/g creatinine (microgram/g-Cr), and the data ranged from 2.5 to 912 micrograms/g-Cr. Forty-two percent of the study participants had urine mercury concentrations that exceeded the ACGIH biological exposure index (BEI) of 35 micrograms/g-Cr. Urinary NAG excretion is considered a biological marker of preclinical, nonspecific microdamage to the kidney's proximal tubule cells. The mean urine NAG concentration was 3.6 International Units/g-Cr (IU/g-Cr) with a range of 0.5 to 11.5 IU/g-Cr. Three workers had urine NAG levels in excess of the reference values. Correlation analyses found statistically significant correlations between airborne mercury exposure and urine mercury level (P = 0.01), and between urine mercury level and urine NAG excretion (P = 0.01). In addition, the airborne mercury exposure data and urine mercury data were segregated by job tasks. A Wilcoxon rank sum test revealed significant correlations between tasks and mercury exposure (P = 0.03), and between tasks and urine mercury level (P = 0.02). The tasks with the highest mean airborne mercury exposures were "burning the mercury-gold amalgam" and "gold refining/smelting". Recommendations were provided for improving the retort design to better contain mercury, for ventilation in the gold shops, and for medical surveillance and educational programs.

  5. Selecting accurate post-elimination monitoring tools to prevent reemergence of urogenital schistosomiasis in Morocco: a pilot study.

    PubMed

    Balahbib, Abdelaali; Amarir, Fatima; Corstjens, Paul L A M; de Dood, Claudia J; van Dam, Govert J; Hajli, Amina; Belhaddad, Meryem; El Mansouri, Bouchra; Sadak, Abderrahim; Rhajaoui, Mohamed; Adlaoui, El Bachir

    2017-04-06

    After alleged stop of transmission of schistosomiasis and further down the line in post elimination settings, sensitive tools are required to monitor infection status to prevent potential re-emergence. In Rahala, where transmission cycle of Schistosoma haematobium is interrupted since 2004 but where 30% of snails are still infected by S. bovis, potential human S. bovis infection can't be excluded. As methods based on egg-counts do not provide the required sensitivity, antibody or antigen assays are envisaged as the most appropriate tools for this type of monitoring. In this pilot study, the performances of three assays were compared: two commercially available antibody tests (ELISA and haemagglutination format) indicating exposure, and an antigen test (lateral flow strip format) demonstrating active infection. All 37 recruited study participants resided in Rahala (Akka, province Tata, Morocco). Participants had been diagnosed and cured from schistosomiasis in the period between 1983 and 2003. In 2015 these asymptomatic participants provided fresh clinical samples (blood and urine) for analysis with the aforementioned diagnostics tests. No eggs were identified in the urine of the 37 participants. The haemagglutination test indicated 6 antibody positives whereas the ELISA indicated 28 antibody positives, one indecisive and one false positive. ELISA and haemagglutination results matched for 18 individuals, amongst which 5 out of 6 haemagglutination positives. With the antigen test (performed on paired serum and urine samples), serum from two participants (cured 21 and 32 years ago) indicated the presence of low levels of the highly specific Schistosoma circulating anodic antigen (CAA), demonstrating low worm level infections (less than 5 pg/ml corresponding to probably single worm pair). One tested also CAA positive with urine. ELISA indicated the presence of human anti-Schistosoma antibodies in these two CAA positive cases, haemagglutination results were negative. To prevent reemergence of schistosomiasis in Morocco current monitoring programs require specific protocols that include testing of antibody positives for active infection by the UCP-LF CAA test, the appropriate diagnostic tool to identify Schistosoma low grade infections in travelers, immigrants and assumed cured cases. The test is genus specific will also identify infections related to S. bovis.

  6. Effect of a commercial anion dietary supplement on acid-base balance, urine volume, and urinary ion excretion in male goats fed oat or grass hay diets.

    PubMed

    Stratton-Phelps, Meri; House, John K

    2004-10-01

    To determine whether feeding a commercial anionic dietary supplement as a urinary acidifier to male goats may be useful for management of urolithiasis. 8 adult sexually intact male Toggenburg, Saanen, and Nubian goats. Goats were randomly assigned by age-, breed-, and weight-matched pairs to an oat or grass hay diet that was fed for 12 days. On days 13 to 14 (early sample collection time before supplementation), measurements were made of blood and urine sodium, potassium, calcium, magnesium, chloride, phosphorus, and sulfur concentrations; blood and urine pH; urine production; and water consumption. During the next 28 days, the anionic dietary supplement was added to the oat and grass hay diets to achieve a dietary cation-anion difference of 0 mEq/100g of dry matter. Blood and urine samples were analyzed during dietary supplementation on days 12 to 13 (middle sample collection time) and 27 to 28 (late sample collection time). Blood bicarbonate, pH, and urine pH of goats fed grass hay and goats fed oat hay were significantly decreased during the middle and late sample collection times, compared with the early sample collection time. Water consumption and urine production in all goats increased significantly during the late sample collection time, compared with the early sample collection time. The anionic dietary supplement used in our study increases urine volume, alters urine ion concentrations, and is an efficacious urinary acidifier in goats. Goats treated with prolonged anionic dietary supplementation should be monitored for secondary osteoporosis from chronic urinary calcium loss.

  7. Biological exposure indices of pyrrole adducts in serum and urine for hazard assessment of n-hexane exposure.

    PubMed

    Yin, Hongyin; Zhang, Chunling; Guo, Ying; Shao, Xiaoying; Zeng, Tao; Zhao, Xiulan; Xie, Keqin

    2014-01-01

    Pyrrole adducts might be used as a biomarker for monitoring occupational exposure to n-hexane, but the Biological Exposure Indices of pyrrole adducts in serum and urine are still unknown. The current study was designed to investigate the biological exposure limit of pyrrole adducts for hazard assessment of n-hexane. Male Wistar rats were given daily dose of 500, 1000, 1500, 2000, 4000 mg/kg bw n-hexane by gavage for 24 weeks. The levels of pyrrole adducts in serum and urine were determined at 8, 24 hours postdose once a week. The Biological Exposure Indices was evaluated by neurological evaluation and the levels of pyrrole adducts. The difference in pyrrole adducts formation between humans and rats were estimated by using in vitro test. Dose-dependent effects were observed between the doses of n-hexane and pyrrole adducts in serum and urine, and the levels of pyrrole adduct in serum and urine approached a plateau at week 4. There was a significantly negative correlation between the time to paralysis and the level of pyrrole adducts in serum and urine, while a positive correlation between gait score and levels of pyrrole adducts in serum and urine was observed. In vitro, pyrrole adducts formed in human serum was about two times more than those in rat serum at the same level of 2,5-HD. It was concluded that the BEIs of pyrrole adducts in humans were 23.1 ± 5.91 nmol/ml in serum 8 h postdose, 11.7 ± 2.64 nmol/ml in serum 24 h postdose, 253.8 ± 36.3 nmol/ml in urine 8 h postdose and 54.6 ± 15.42 nmol/ml in urine 24 h postdose.

  8. Biological Exposure Indices of Pyrrole Adducts in Serum and Urine for Hazard Assessment of n-Hexane Exposure

    PubMed Central

    Yin, Hongyin; Zhang, Chunling; Guo, Ying; Shao, Xiaoying; Zeng, Tao; Zhao, Xiulan; Xie, Keqin

    2014-01-01

    Background Pyrrole adducts might be used as a biomarker for monitoring occupational exposure to n-hexane, but the Biological Exposure Indices of pyrrole adducts in serum and urine are still unknown. The current study was designed to investigate the biological exposure limit of pyrrole adducts for hazard assessment of n-hexane. Methods Male Wistar rats were given daily dose of 500, 1000, 1500, 2000, 4000 mg/kg bw n-hexane by gavage for 24 weeks. The levels of pyrrole adducts in serum and urine were determined at 8, 24 hours postdose once a week. The Biological Exposure Indices was evaluated by neurological evaluation and the levels of pyrrole adducts. The difference in pyrrole adducts formation between humans and rats were estimated by using in vitro test. Results Dose-dependent effects were observed between the doses of n-hexane and pyrrole adducts in serum and urine, and the levels of pyrrole adduct in serum and urine approached a plateau at week 4. There was a significantly negative correlation between the time to paralysis and the level of pyrrole adducts in serum and urine, while a positive correlation between gait score and levels of pyrrole adducts in serum and urine was observed. In vitro, pyrrole adducts formed in human serum was about two times more than those in rat serum at the same level of 2,5-HD. Conclusion It was concluded that the BEIs of pyrrole adducts in humans were 23.1±5.91 nmol/ml in serum 8 h postdose, 11.7±2.64 nmol/ml in serum 24 h postdose, 253.8±36.3 nmol/ml in urine 8 h postdose and 54.6±15.42 nmol/ml in urine 24 h postdose. PMID:24465904

  9. Urine pH is an indicator of dietary acid-base load, fruit and vegetables and meat intakes: results from the European Prospective Investigation into Cancer and Nutrition (EPIC)-Norfolk population study.

    PubMed

    Welch, Ailsa A; Mulligan, Angela; Bingham, Sheila A; Khaw, Kay-Tee

    2008-06-01

    Evidence exists that a more acidic diet is detrimental to bone health. Although more precise methods exist for measurement of acid-base balance, urine pH reflects acid-base balance and is readily measurable but has not been related to habitual dietary intake in general populations. The present study investigated the relationship between urine pH and dietary acid-base load (potential renal acid load; PRAL) and its contributory food groups (fruit and vegetables, meats, cereal and dairy foods). There were 22,034 men and women aged 39-78 years living in Norfolk (UK) with casual urine samples and dietary intakes from the European Prospective Investigation into Cancer and Nutrition (EPIC)-Norfolk FFQ. A sub-study (n 363) compared pH in casual samples and 24 h urine and intakes from a 7 d diary and the FFQ. A more alkaline diet (low PRAL), high fruit and vegetable intake and lower consumption of meat was significantly associated with a more alkaline urine pH before and after adjustment for age, BMI, physical activity and smoking habit and also after excluding for urinary protein, glucose, ketones, diagnosed high blood pressure and diuretic medication. In the sub-study the strongest relationship was found between the 24 h urine and the 7 d diary. In conclusion, a more alkaline diet, higher fruit and vegetable and lower meat intake were related to more alkaline urine with a magnitude similar to intervention studies. As urine pH relates to dietary acid-base load its use to monitor change in consumption of fruit and vegetables, in individuals, warrants further investigation.

  10. Dual mechanism of brain injury and novel treatment strategy in maple syrup urine disease.

    PubMed

    Zinnanti, William J; Lazovic, Jelena; Griffin, Kathleen; Skvorak, Kristen J; Paul, Harbhajan S; Homanics, Gregg E; Bewley, Maria C; Cheng, Keith C; Lanoue, Kathryn F; Flanagan, John M

    2009-04-01

    Maple syrup urine disease (MSUD) is an inherited disorder of branched-chain amino acid metabolism presenting with life-threatening cerebral oedema and dysmyelination in affected individuals. Treatment requires life-long dietary restriction and monitoring of branched-chain amino acids to avoid brain injury. Despite careful management, children commonly suffer metabolic decompensation in the context of catabolic stress associated with non-specific illness. The mechanisms underlying this decompensation and brain injury are poorly understood. Using recently developed mouse models of classic and intermediate maple syrup urine disease, we assessed biochemical, behavioural and neuropathological changes that occurred during encephalopathy in these mice. Here, we show that rapid brain leucine accumulation displaces other essential amino acids resulting in neurotransmitter depletion and disruption of normal brain growth and development. A novel approach of administering norleucine to heterozygous mothers of classic maple syrup urine disease pups reduced branched-chain amino acid accumulation in milk as well as blood and brain of these pups to enhance survival. Similarly, norleucine substantially delayed encephalopathy in intermediate maple syrup urine disease mice placed on a high protein diet that mimics the catabolic stress shown to cause encephalopathy in human maple syrup urine disease. Current findings suggest two converging mechanisms of brain injury in maple syrup urine disease including: (i) neurotransmitter deficiencies and growth restriction associated with branched-chain amino acid accumulation and (ii) energy deprivation through Krebs cycle disruption associated with branched-chain ketoacid accumulation. Both classic and intermediate models appear to be useful to study the mechanism of brain injury and potential treatment strategies for maple syrup urine disease. Norleucine should be further tested as a potential treatment to prevent encephalopathy in children with maple syrup urine disease during catabolic stress.

  11. Urine pretreatment for waste water processing systems. [for space station

    NASA Technical Reports Server (NTRS)

    Winkler, H. E.; Verostko, C. E.; Dehner, G. F.

    1983-01-01

    Recovery of high quality water from urine is an essential part of life support on a Space Station to avoid costly launch and resupply penalties. Water can be effectively recovered from urine by distillation following pretreatment by a chemical agent to inhibit microorganism contamination and fix volatile ammonia constituents. This paper presents the results of laboratory investigations of several pretreatment chemicals which were tested at several concentration levels in combination with sulfuric acid in urine. The optimum pretreatment formulation was then evaluated with urine in the Hamilton Standard Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES). Over 2600 hours of test time was accumulated. Results of these laboratory and system tests are presented in this paper.

  12. Silicone wristbands compared with traditional polycyclic aromatic hydrocarbon exposure assessment methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixon, Holly M.; Scott, Richard P.; Holmes, Darrell

    Currently there is a lack of inexpensive, easy-to-use technology to evaluate human exposure to environmental chemicals, including polycyclic aromatic hydrocarbons (PAHs). This is the first study in which silicone wristbands were deployed alongside other PAH exposure assessment methodologies. Wristbands were used within an established Columbia Center for Children’s Environmental Health birth cohort and compared to two traditional personal PAH exposure assessment methods: biological sampling with urine and active air monitoring with samplers (i.e. polyurethane foam (PUF) and filter) housed in backpacks. All samplers were deployed simultaneously on 22 pregnant women for 48-hours. Each woman provided one spot urine sample atmore » the end of the 48-hour period. Sixty-two and 20 PAHs were quantified in the wristbands and PUF/filter, respectively; and eight hydroxy-PAH (OH-PAH) metabolites were quantified in the urine. PAHs in the PUF/filter and OH-PAHs correlate significantly for two of the eight comparisons (rs=0.53 and p=0.01; rs=0.44 and p=0.04). PAHs in the wristband and OH-PAHs correlate significantly for four of the eight comparisons; 1-OH-phenanthrene and 1-OH-pyrene strongly correlate with the parent PAHs in the wristband (rs=0.76 and p=<0.0001; rs=0.66 and p=0.0009). These results suggest wristbands are more closely associated with OH-PAHs in urine than active personal air monitoring methods.« less

  13. The use of body mass changes as a practical measure of dehydration in team sports.

    PubMed

    Harvey, Gemma; Meir, Rudi; Brooks, Lyndon; Holloway, Kate

    2008-11-01

    Body mass changes, hematocrit, specific gravity and urine colour were recorded during two games of soccer to determine which of these methods was the most practical in a field setting for monitoring dehydration. Members (n=13) of a premiership soccer team with a mean age of 22.6 (+/-4.9) years old, height of 177.8 (+/-7.1)cm and sum of skinfolds (four sites) of 37 (+/-12.8) were invited to participate in this study with 11 participating in each game. Players had weight, hematocrit, specific gravity and urine colour recorded pre- and post-game. Players were allowed to ingest fluid ad libitum throughout the matches with the amount consumed recorded. Urine excretion was also recorded and included in the calculation of final body mass loss (kg). A mean ambient temperature of 21 degrees C and relative humidity 77% was recorded for both games. Pre- and post-game body mass, sweat loss, hematocrit, urine specific gravity and colour were significantly different (p<0.01) for both games. Linear mixed effects models were fitted to the data in order to identify an optimal prediction equation for sweat loss. The model predicting from mass change was clearly the best fitting. The results demonstrate that a change in body mass during a game of soccer is an effective method of monitoring dehydration due to sweat loss when compared to other known methods that may be invasive and inappropriate in the field.

  14. Confirmatory analysis of 17beta-boldenone, 17alpha-boldenone and androsta-1,4-diene-3,17-dione in bovine urine by liquid chromatography-tandem mass spectrometry.

    PubMed

    Draisci, Rosa; Palleschi, Luca; Ferretti, Emanuele; Lucentini, Luca; delli Quadri, Fernanda

    2003-06-15

    A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for confirmatory analysis of 17beta-boldenone (17beta-BOL), 17alpha-boldenone (17alpha-BOL) and androsta-1,4-diene-3,17-dione (ADD) in bovine urine was developed. [2H(2)]17beta-Testosterone (17beta-T-d(2)) was used as the internal standard. Sample preparation involved enzymatic hydrolysis and purification on a C(18) solid-phase extraction column. Chromatographic separation of the analytes was obtained using an RP-C(18) HPLC column. LC-MS-MS detection was carried out with an atmospheric pressure chemical ionisation (APCI) source equipped with a heated nebulizer (HN) interface operating in the positive ion mode. For unambiguous hormone confirmation, three analyte precursor-product ion combinations were monitored during multiple-reaction monitoring (MRM) LC-MS-MS analysis. Overall recovery (%), repeatability (relative standard deviations, RSD, %) and within-laboratory reproducibility (RSD, %) ranged from 92.2 to 97.7%, from 6.50 to 2.94% and from 13.50 to 5.04%, respectively, for all analytes. The limit of quantification in bovine urine was 0.20 ng ml(-1) for 17beta-BOL and ADD and 0.50 ng ml(-1) for 17alpha-BOL. The validated method was successfully applied for determination of 17beta-BOL, 17alpha-BOL and ADD in a large number of bovine urine samples collected within the national Official Residue Control Program.

  15. Quantification of Inflammasome Adaptor Protein ASC in Biological Samples by Multiple-Reaction Monitoring Mass Spectrometry.

    PubMed

    Ulke-Lemée, Annegret; Lau, Arthur; Nelson, Michelle C; James, Matthew T; Muruve, Daniel A; MacDonald, Justin A

    2018-06-09

    Inflammation is an integral component of many diseases, including chronic kidney disease (CKD). ASC (apoptosis-associated speck-like protein containing CARD, also PYCARD) is the key inflammasome adaptor protein in the innate immune response. Since ASC specks, a macromolecular condensate of ASC protein, can be released by inflammasome-activated cells into the extracellular space to amplify inflammatory responses, the ASC protein could be an important biomarker in diagnostic applications. Herein, we describe the development and validation of a multiple reaction monitoring mass spectrometry (MRM-MS) assay for the accurate quantification of ASC in human biospecimens. Limits of detection and quantification for the signature DLLLQALR peptide (used as surrogate for the target ASC protein) were determined by the method of standard addition using synthetic isotope-labeled internal standard (SIS) peptide and urine matrix from a healthy donor (LOQ was 8.25 pM, with a ~ 1000-fold linear range). We further quantified ASC in the urine of CKD patients (8.4 ± 1.3 ng ASC/ml urine, n = 13). ASC was positively correlated with proteinuria and urinary IL-18 in CKD samples but not with urinary creatinine. Unfortunately, the ASC protein is susceptible to degradation, and patient urine that was thawed and refrozen lost 85% of the ASC signal. In summary, the MRM-MS assay provides a robust means to quantify ASC in biological samples, including clinical biospecimens; however, sample collection and storage conditions will have a critical impact on assay reliability.

  16. Comparisons of different measurements for monitoring diabetic cats treated with porcine insulin zinc suspension.

    PubMed

    Martin, G J; Rand, J S

    2007-07-14

    Clinical measurements, including a subjective clinical score and water intake, and biochemical measurements, including blood glucose, fructosamine, beta-hydroxybutyrate, cholesterol, triglycerides, triglycerides corrected for free glycerol, glycerol and urine glucose were compared for monitoring diabetic cats treated with porcine insulin zinc suspension. The data were grouped by subjective clinical score and the sensitivity of each measurement in differentiating the grouped data was assessed. None of the measurements was able to differentiate between the ranked clinical score groups, but two-hourly measurements of blood glucose over 24 hours, water intake, urine glucose and fructosamine were useful in differentiating cats that subjectively had the water and food consumption and general appearance of a normal cat from cats in which the signs of diabetes were less well controlled. Measurements of plasma lipids were not well correlated with the other measurements. The measurements that were most closely correlated with apparently perfect clinical control were the J index, water intake and maximum and mean blood glucose concentrations. In practice, water intake, maximum blood glucose concentration, mean blood glucose concentration and urine glucose would be the most useful indicators of clinical control in diabetic cats treated with porcine insulin zinc suspension.

  17. Urinary metabolic insights into host-gut microbial interactions in healthy and IBD children

    PubMed Central

    Martin, Francois-Pierre; Su, Ming-Ming; Xie, Guo-Xiang; Guiraud, Seu Ping; Kussmann, Martin; Godin, Jean-Philippe; Jia, Wei; Nydegger, Andreas

    2017-01-01

    AIM To identify metabolic signatures in urine samples from healthy and inflammatory bowel disease (IBD) children. METHODS We applied liquid chromatography and gas chromatography coupled to targeted mass spectrometry (MS)-based metabolite profiling to identify and quantify bile acids and host-gut microbial metabolites in urine samples collected from 21 pediatric IBD patients monitored three times over one year (baseline, 6 and 12 mo), and 27 age- and gender-matched healthy children. RESULTS urinary metabolic profiles of IBD children differ significantly from healthy controls. Such metabolic differences encompass central energy metabolism, amino acids, bile acids and gut microbial metabolites. In particular, levels of pyroglutamic acid, glutamic acid, glycine and cysteine, were significantly higher in IBD children in the course of the study. This suggests that glutathione cannot be optimally synthesized and replenished. Whilst alterations of the enterohepatic circulation of bile acids in pediatric IBD patients is known, we show here that non-invasive urinary bile acid profiling can assess those altered hepatic and intestinal barrier dysfunctions. CONCLUSION The present study shows how non-invasive sampling of urine followed by targeted MS-based metabonomic analysis can elucidate and monitor the metabolic status of children with different GI health/disease status. PMID:28611517

  18. Longitudinal Urinary Protein Variability in Participants of the Space Flight Simulation Program.

    PubMed

    Khristenko, Nina A; Larina, Irina M; Domon, Bruno

    2016-01-04

    Urine is a valuable material for the diagnosis of renal pathologies and to investigate the effects of their treatment. However, the variability in protein abundance in the context of normal homeostasis remains a major challenge in urinary proteomics. In this study, the analysis of urine samples collected from healthy individuals, rigorously selected to take part in the MARS-500 spaceflight simulation program, provided a unique opportunity to estimate normal concentration ranges for an extended set of urinary proteins. In order to systematically identify and reliably quantify peptides/proteins across a large sample cohort, a targeted mass spectrometry method was developed. The performance of parallel reaction monitoring (PRM) analyses was improved by implementing tight control of the monitoring windows during LC-MS/MS runs, using an on-the-fly correction routine. Matching the experimentally obtained MS/MS spectra with reference fragmentation patterns allowed dependable peptide identifications to be made. Following optimization and evaluation, the targeted method was applied to investigate protein abundance variability in 56 urine samples, collected from six volunteers participating in the MARS-500 program. The intrapersonal protein concentration ranges were determined for each individual and showed unexpectedly high abundance variation, with an average difference of 1 order of magnitude.

  19. A study examining the bias of albumin and albumin/creatinine ratio measurements in urine.

    PubMed

    Jacobson, Beryl E; Seccombe, David W; Katayev, Alex; Levin, Adeera

    2015-10-01

    The objective of the study was to examine the bias of albumin and albumin/creatinine (ACR) measurements in urine. Pools of normal human urine were augmented with purified human serum albumin to generate a series of 12 samples covering the clinical range of interest for the measurement of ACR. Albumin and creatinine concentrations in these samples were analyzed three times on each of 3 days by 24 accredited laboratories in Canada and the USA. Reference values (RV) for albumin measurements were assigned by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) comparative method and gravimetrically. Ten random urine samples (check samples) were analyzed as singlets and albumin and ACR values reported according to the routine practices of each laboratory. Augmented urine pools were shown to be commutable. Gravimetrically assigned target values were corrected for the presence of endogenous albumin using the LC-MS/MS comparative method. There was excellent agreement between the RVs as assigned by these two methods. All laboratory medians demonstrated a negative bias for the measurement of albumin in urine over the concentration range examined. The magnitude of this bias tended to decrease with increasing albumin concentrations. At baseline, only 10% of the patient ACR values met a performance limit of RV ± 15%. This increased to 84% and 86% following post-analytical correction for albumin and creatinine calibration bias, respectively. International organizations should take a leading role in the standardization of albumin measurements in urine. In the interim, accuracy based urine quality control samples may be used by clinical laboratories for monitoring the accuracy of their urinary albumin measurements.

  20. Standardizing the experimental conditions for using urine in NMR-based metabolomic studies with a particular focus on diagnostic studies: a review.

    PubMed

    Emwas, Abdul-Hamid; Luchinat, Claudio; Turano, Paola; Tenori, Leonardo; Roy, Raja; Salek, Reza M; Ryan, Danielle; Merzaban, Jasmeen S; Kaddurah-Daouk, Rima; Zeri, Ana Carolina; Nagana Gowda, G A; Raftery, Daniel; Wang, Yulan; Brennan, Lorraine; Wishart, David S

    The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.

  1. Urine Culture Follow-up and Antimicrobial Stewardship in a Pediatric Urgent Care Network.

    PubMed

    Saha, Dipanwita; Patel, Jimisha; Buckingham, Don; Thornton, David; Barber, Terry; Watson, Joshua R

    2017-04-01

    Empiric antibiotic therapy for presumed urinary tract infection (UTI) leads to unnecessary antibiotic exposure in many children whose urine culture results fail to confirm the diagnosis. The objective of this quality improvement study was to improve follow-up management of negative urine culture results in the off-campus urgent care network of Nationwide Children's Hospital to reduce inappropriate antibiotic exposure in children. A multidisciplinary task force developed and implemented a protocol for routine nurse and clinician follow-up of urine culture results, discontinuation of unnecessary antibiotics, and documentation in the electronic medical record. Monthly antibiotic discontinuation rates were tracked in empirically treated patients with negative urine culture results from July 2013 through December 2015. Statistical process control methods were used to track improvement over time. Fourteen-day return visits for UTIs were monitored as a balancing measure. During the study period, 910 patients received empiric antibiotic therapy for UTIs but had a negative urine culture result. The antibiotic discontinuation rate increased from 4% to 84%, avoiding 3429 (40%) of 8648 antibiotic days prescribed. Among patients with discontinued antibiotics, none was diagnosed with a UTI within 14 days of the initial urgent care encounter. Implementation of a standard protocol for urine culture follow-up and discontinuation of unnecessary antibiotics was both effective and safe in a high-volume pediatric urgent care network. Urine culture follow-up management is an essential opportunity for improved antimicrobial stewardship in the outpatient setting that will affect many patients by avoiding a substantial number of antibiotic days. Copyright © 2017 by the American Academy of Pediatrics.

  2. Chromium in urine, serum and red blood cells in the biological monitoring of workers exposed to different chromium valency states.

    PubMed

    Minoia, C; Cavalleri, A

    1988-06-01

    Using personal air sampling exposure to hexavalent and trivalent chromium was measured in 22 workers mainly exposed to Cr(VI) and in 15 workers mainly exposed to Cr(III) as basic chromium sulphate. Determination of Cr(VI) in the urine of all the subjects using a selective technique by ETA-AAS and liquid anion exchangers failed to show detectable amounts of the hexavalent form, the detection limit of the technique being 0.05 micrograms/L. A clear relationship between exposure and postshift urinary total chromium was found in subjects exposed to Cr(VI), while urinary levels in workers exposed to chromic sulphate high concentration proved lower. Determination of total chromium in serum and red blood cells showed a significant increase of chromium levels in erythrocytes of workers exposed to Cr(VI) while in subjects mainly exposed to Cr(III) an increase of the serum fraction was observed. The results demonstrate that Cr(III) is absorbed through the respiratory tract, but its kinetics and distribution in the body are not the same as for Cr(VI), and are not adequately monitored by short-term urinary determinations. Oxidation states of chromium largely influence uptake, mechanism of absorption, transport and organ distribution as well as toxicity of chromium-containing compounds. In particular, hexavalent derivatives are known to induce adverse effects, both acute and chronic, in occupationally exposed subjects, while there is little conclusive evidence for toxic effects caused by trivalent chromium compounds. Biological monitoring of exposure to chromium(VI) has usually been performed by determining total chromium levels in urine, whereas biological monitoring data in subjects occupationally exposed to Cr(III) are still scanty.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Determination of γ-hydroxybutyrate in human urine samples by ion exclusion and ion exchange two-dimensional chromatography system.

    PubMed

    Liu, Junwei; Deng, Zhifen; Zhu, Zuoyi; Wang, Yong; Wang, Guoqing; Sun, Yu-An; Zhu, Yan

    2017-12-15

    A two-dimensional ion chromatography system was developed for the determination of γ-hydroxybutyrate (GHB) in human urine samples. Ion exclusion chromatography was used in the first dimensional separation for elimination of urine matrices and detection of GHB above 10mgL -1 , ion exchange chromatography was used in the second dimensional separation via column-switching technique for detection of GHB above 0.08mgL -1 . Under the optimized chromatographic conditions, the ion exclusion and ion exchange chromatography separation system exhibited satisfactory repeatability (RSD<3.1%, n=6) and good linearity in the range of 50-1000mgL -1 and 0.5-100mgL -1 , respectively. By this method, concentrations of GHB in the selected human urine samples were detected in the range of 0-1.57mgL -1 . The urine sample containing 0.89mgL -1 GHB was selected to evaluate the accuracy; the spiked recoveries of GHB were 95.9-102.8%. The results showed that the two-dimensional ion chromatography system was convenient and practical for the determination of GHB in human urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. SPE-GC/FTD determination of N-methyl-2-pyrrolidone and its metabolites in urine.

    PubMed

    Kubota, Ryuichi; Endo, Yoko; Takeuchi, Akito; Inoue, Yoshinori; Ogata, Hiroko; Ogawa, Masanori; Nakagawa, Tomoo; Onda, Nobuhiko; Endo, Ginji

    2007-07-01

    An analytical method using a combination of solid-phase extraction (SPE) and gas chromatography with a flame thermionic detector (GC/FTD) was developed for determination of N-methyl-2-pyrrolidone (NMP), N-methylsuccinimide (MSI), and 2-hydroxy-N-methylsuccinimide (2-HMSI) in human urine. The SPE cartridge of poly(divinylbenzene/hydroxymethacrylate) used was directly loaded with urine sample, followed by elution with methyl isobutyl ketone (MIBK) and subsequent centrifugation, and the supernatant was injected into the capillary GC using a DB1701. This method allowed efficient separation of NMP, MSI, and 2-HMSI, which were nearly free of interference by other GC peaks arising from urine. Recoveries of NMP, MSI, and 2-HMSI from the SPE cartridge were about 98, 101, and 67%, respectively, with limits of detection of 0.04, 0.02, and 0.06 mg/L, respectively, which met the regulatory requirements. The present method was used for assay in biological monitoring of workers exposed to NMP in their occupational environment.

  5. Water Treatment Systems for Long Spaceflights

    NASA Technical Reports Server (NTRS)

    FLynn, Michael T.

    2012-01-01

    Space exploration will require new life support systems to support the crew on journeys lasting from a few days to several weeks, or longer. These systems should also be designed to reduce the mass required to keep humans alive in space. Water accounts for about 80 percent of the daily mass intake required to keep a person alive. As a result, recycling water offers a high return on investment for space life support. Water recycling can also increase mission safety by providing an emergency supply of drinking water, where another supply is exhausted or contaminated. These technologies also increase safety by providing a lightweight backup to stored supplies, and they allow astronauts to meet daily drinking water requirements by recycling the water contained in their own urine. They also convert urine into concentrated brine that is biologically stable and nonthreatening, and can be safely stored onboard. This approach eliminates the need to have a dedicated vent to dump urine overboard. These needs are met by a system that provides a contaminant treatment pouch, referred to as a urine cell or contaminant cell, that converts urine or another liquid containing contaminants into a fortified drink, engineered to meet human hydration, electrolyte, and caloric requirements, using a variant of forward osmosis (FO) to draw water from a urine container into the concentrated fortified drink as part of a recycling stage. An activated carbon pretreatment removes most organic molecules. Salinity of the initial liquid mix (urine plus other) is synergistically used to enhance the precipitation of organic molecules so that activated carbon can remove most of the organics. A functional osmotic bag is then used to remove inorganic contaminants. If a contaminant is processed for which the saline content is different than optimal for precipitating organic molecules, the saline content of the liquid should be adjusted toward the optimal value for that contaminant. A first urine treatment method converts urine into a fortified sports drink, resembling Gatorade, using a first urine cell.

  6. Ultrasonic Device Monitors Fullness Of The Bladder

    NASA Technical Reports Server (NTRS)

    Heyman, Joseph S.; Blalock, Travis; Companion, John A.; Cavalier, AL; Mineo, Beth A.

    1991-01-01

    Ultrasonic device monitors fullness of bladder is self-contained, lightweight, portable, powered by battery, and tailored for specific patient through software modified as patient's behavior changes. Essentially quantifies amount of urine in bladder by measuring relative distension of bladder and gives suitable alarm telling patient to eliminate. Intended for use in training people who are incontinent and cannot identify when elimination necessary.

  7. Determination of designer doping agent--2-ethylamino-1-phenylbutane--in dietary supplements and excretion study following single oral supplement dose.

    PubMed

    Wójtowicz, Marzena; Jarek, Anna; Chajewska, Katarzyna; Turek-Lepa, Ewa; Kwiatkowska, Dorota

    2015-11-10

    The quantitative analysis of a new designer doping agent, 2-ethylamino-1-phenylbutane (EAPB) and its metabolite, 2-amino-1-phenylbutane (APB) in urine samples, and the determination of EAPB in dietary supplement samples, have been presented. The main purpose of the present study was to develop simple and reliable gas chromatography-mass spectrometry method (GC-MS) for excretion study following a single oral administration of dietary supplements containing EAPB. Three analytical methods for the determination of EAPB in urine and supplement samples, and APB in urine samples using the GC-MS system, have been validated. The method of the determination of EAPB in supplement samples was applied to analyze seventeen dietary supplements, CRAZE and DETONATE. Two other methods were used to determine the urinary excretion profile of EAPB and APB in the case of three healthy volunteers and, on further investigation, it was applied to the anti-doping control in sport. Quantification was obtained on the basis of the ions at m/z 86, 58 and 169, monitored for EAPB, APB and diphenylamine (used as an internal standard), respectively. The limits of detection and quantification were 2.4 and 7.3μg/g for EAPB in the case of supplement analysis, 2.9 and 8.8ng/mL for EAPB in the case of urine analysis, and 3.2 and 9.7ng/mL for APB. The other validation parameters as linearity, precision and trueness have been also investigated with the acceptable results. The extraction yield of all presented methods was above 69%. EAPB was detected in fourteen analyzed supplements (not included EAPB in their labels) and its content varied between 1.8 and 16.1mg/g. Following oral administration of three supplements with EAPB to one male and two female volunteers, the parent compound of EAPB and its metabolite were monitored and the excretion parameters as the maximum concentration of the analyte in urine (2.2-4.2μg/mL for EAPB; 1.1-5.1μg/mL for APB) and the time for the maximum height of the excretion peak (2-8h and 22h in one case for EAPB; 20-22h and 4h in one case for APB) have been indicated. EAPB and APB were detected at the level above 50ng/mL (50% of the minimum required performance level for stimulants in the anti-doping control in-competition in sport) in the urine up to 46-106h and 58-120h, respectively. Additionally, the result of the anti-doping control during swimming competition of one athlete, whose urine sample was analyzed for stimulants and narcotics, has been presented. The qualitative and quantitative analyses of new designer agents in urine samples and the excretion studies of these substances are of a great importance in the anti-doping control in sport. Moreover, the presentation of detection examples of these agents in supplements that haven't got included an information about them in the labeling, make athletes (and other supplement customers) more and more aware of the risk of the supplement use and possible health and doping consequences. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Development and validation of an LC-MS/MS analysis for simultaneous determination of delphinidin-3-glucoside, cyanidin-3-glucoside and cyanidin-3-(6-malonylglucoside) in human plasma and urine after blood orange juice administration.

    PubMed

    Giordano, Lucia; Coletta, Walter; Rapisarda, Paolo; Donati, Maria Benedetta; Rotilio, Domenico

    2007-12-01

    Blood orange juice has a high content in anthocyanins, especially represented by delphinidin-3-glucoside (D3G), cyanidin-3-glucoside (C3G) and cyanidin-3-(6-malonylglucoside) (CMG). An LC-MS/MS method for the simultaneous determination of D3G and C3G in human plasma and urine was developed and validated. After sample preparation by SPE, chromatographic separation was performed with an RP-C(18) column, using a water/methanol linear gradient. The quantitation of target compounds was determined by multiple reaction monitoring (MRM) mode, using ESI. The method showed good selectivity, sensitivity (LOD = 0.05 and 0.10 ng/mL for C3G in plasma and urine, respectively; LOD = 0.10 ng/mL for D3G in plasma and urine), linearity (0.20-200 ng/mL; r >or= 0.998), intra- and interday precision and accuracy (

  9. Determination of the GABA analogue succinic semialdehyde in urine and cerebrospinal fluid by dinitrophenylhydrazine derivatization and liquid chromatography-tandem mass spectrometry: application to SSADH deficiency.

    PubMed

    Struys, E A; Jansen, E E W; Gibson, K M; Jakobs, C

    2005-01-01

    Succinic semialdehyde (SSA) accumulates in the inborn error of meta- bolism succinic semialdehyde dehydrogenase deficiency owing to impaired enzymatic conversion to succinic acid. We developed a stable-isotope dilution liquid chromato- graphy-tandem mass spectrometry method for the determination of SSA in urine and cerebrospinal fluid samples. Stable-isotope-labelled [13C4]SSA, serving as internal standard, was prepared by reaction of ninhydrin with L-[13C5]glutamic acid. SSA in body fluids was converted to its dinitrophenylhydrazine (DNPH) derivative, without sample purification prior to the derivatization procedure. The DNPH derivative of SSA was injected onto a C18 analytical column and chromatography was performed by isocratic elution. Detection was accomplished by tandem mass spectrometry operating in the negative multiple-reaction monitoring mode. The limit of detection was 10 nmol/L and the calibration curves over the range 0-500 pmol of SSA showed good linearity (r2 > 0.99). The intra-day coefficient of variation (n = 10) for urine was 2.7% and inter-day coefficient of variation (n = 5) for urine was 8.5%. The average recoveries performed on two levels by enriching urine and cerebrospinal fluid samples ranged between 85 and 115%, with coefficients of variation < 8%. The method enabled the first determination of normal values for SSA in urine and pathological values of SSA in urine and cerebrospinal fluid samples derived from patients with succinic semialdehyde dehydrogenase deficiency.

  10. Biomonitoring of exposure to N-methyl-2-pyrrolidone in workers of the automobile industry.

    PubMed

    Meier, Swetlana; Schindler, Birgit K; Koslitz, Stephan; Koch, Holger M; Weiss, Tobias; Käfferlein, Heiko U; Brüning, Thomas

    2013-07-01

    N-methyl-2-pyrrolidone (NMP) is an important organic solvent for varnishes in industry. NMP has been previously shown to be a developmental toxicant in rodents. This study reports current exposures to NMP in the spraying department of an automobile plant using biological monitoring. Two specific metabolites, 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methyl-succinimide (2-HMSI), were analyzed in 69 urine samples of 14 workers exposed to NMP and 9 nonexposed controls. Three different working tasks ('loading' and 'cleaning' of the sprayer system and 'wiping/packing' of the sprayed materials) and three sampling times (preshift, postshift, and preshift of the following day) were studied in exposed workers. Median exposures of 5-HNMP and 2-HMSI in postshift urine of exposed workers were 0.91 and 0.52mg g(-1) creatinine, respectively, whereas median levels in controls were below the limit of detection. Decreased levels of 5-HNMP were observed in preshift urine samples on the following day (0.39mg g(-1) creatinine) in exposed workers, while the concentration of 2-HMSI did not change (0.49mg g(-1) creatinine). Highest exposures occurred during sprayer cleaning with a maximum level of 8.31mg g(-1) creatinine of 5-HNMP in postshift urine. In contrast to 'wipers/packers', no decrease in 5-HNMP could be observed in preshift urine samples on day 2 of the 'loaders' and 'cleaners'. Overall, exposure in terms of 5-HNMP postshift and 2-HMSI preshift of the following day were well below the current biological limit values of the European Union (70 and 20mg g(-1) creatinine). Our results provide initial data on NMP exposure in the automobile industry and suggest that the analysis of 5-HNMP in preshift samples also provides essential information, particularly in situations involving direct handling of liquid NMP-containing formulations.

  11. Novel liquid chromatography-electrospray ionization mass spectrometry method for the quantification in human urine of microbial aromatic acid metabolites derived from dietary polyphenols.

    PubMed

    Gonthier, Marie-Paule; Rios, Laurent Y; Verny, Marie- Anne; Rémésy, Christian; Scalbert, Augustin

    2003-06-15

    An HPLC-ESI-MS-MS method was developed to quantify in human urine fourteen aromatic acids known as metabolites of dietary polyphenols. These metabolites were determined simultaneously in a single 20-min chromatographic analysis with multiple reaction monitoring detection. The inter- and intra-day precisions, calculated from quality control samples were 8.8 and 5.3%, respectively, and the mean accuracy was 2.3%. The method was tested on urine samples collected from one healthy volunteer who consumed a polyphenol-rich diet for 3 days. Increased levels of several aromatic acid metabolites were observed, demonstrating that the method can be used to detect changes in the excretion of microbial metabolites induced by the consumption of polyphenol-containing foods in humans.

  12. Biomarkers of oral exposure to 3-nitro-1,2,4-triazol-5-one (NTO) and 2,4-dinitroanisole (DNAN) in blood and urine of rhesus macaques (Macaca mulatta).

    PubMed

    Hoyt, Nathan; Brunell, Marla; Kroeck, Karl; Hable, Mike; Crouse, Lee; O'Neill, Art; Bannon, Desmond I

    2013-11-01

    The U.S. Department of Defense is using the chemicals 2,4-dinitroanisole (DNAN) and 3-nitro-1, 2,4-triazol-5-one (NTO) in new munitions development. In a screen for biomarkers of exposure, these compounds were measured in urine and blood of male rhesus monkeys after oral doses. NTO peaked at 4 h, with urinary concentrations at least 100-fold higher than that of blood or serum while 4-dinitrophenol (DNP), a metabolite of DNAN, appeared in blood at concentrations 10- to 20-fold higher than the parent compound. For human exposure monitoring, urine is optimal for NTO while the metabolite DNP in blood is best for DNAN.

  13. Urine cell-based DNA methylation classifier for monitoring bladder cancer.

    PubMed

    van der Heijden, Antoine G; Mengual, Lourdes; Ingelmo-Torres, Mercedes; Lozano, Juan J; van Rijt-van de Westerlo, Cindy C M; Baixauli, Montserrat; Geavlete, Bogdan; Moldoveanud, Cristian; Ene, Cosmin; Dinney, Colin P; Czerniak, Bogdan; Schalken, Jack A; Kiemeney, Lambertus A L M; Ribal, Maria J; Witjes, J Alfred; Alcaraz, Antonio

    2018-01-01

    Current standard methods used to detect and monitor bladder cancer (BC) are invasive or have low sensitivity. This study aimed to develop a urine methylation biomarker classifier for BC monitoring and validate this classifier in patients in follow-up for bladder cancer (PFBC). Voided urine samples ( N  = 725) from BC patients, controls, and PFBC were prospectively collected in four centers. Finally, 626 urine samples were available for analysis. DNA was extracted from the urinary cells and bisulfite modificated, and methylation status was analyzed using pyrosequencing. Cytology was available from a subset of patients ( N  = 399). In the discovery phase, seven selected genes from the literature ( CDH13 , CFTR , NID2 , SALL3 , TMEFF2 , TWIST1 , and VIM2 ) were studied in 111 BC and 57 control samples. This training set was used to develop a gene classifier by logistic regression and was validated in 458 PFBC samples (173 with recurrence). A three-gene methylation classifier containing CFTR , SALL3 , and TWIST1 was developed in the training set (AUC 0.874). The classifier achieved an AUC of 0.741 in the validation series. Cytology results were available for 308 samples from the validation set. Cytology achieved AUC 0.696 whereas the classifier in this subset of patients reached an AUC 0.768. Combining the methylation classifier with cytology results achieved an AUC 0.86 in the validation set, with a sensitivity of 96%, a specificity of 40%, and a positive and negative predictive value of 56 and 92%, respectively. The combination of the three-gene methylation classifier and cytology results has high sensitivity and high negative predictive value in a real clinical scenario (PFBC). The proposed classifier is a useful test for predicting BC recurrence and decrease the number of cystoscopies in the follow-up of BC patients. If only patients with a positive combined classifier result would be cystoscopied, 36% of all cystoscopies can be prevented.

  14. Development of a Targeted Urine Proteome Assay for kidney diseases.

    PubMed

    Cantley, Lloyd G; Colangelo, Christopher M; Stone, Kathryn L; Chung, Lisa; Belcher, Justin; Abbott, Thomas; Cantley, Jennifer L; Williams, Kenneth R; Parikh, Chirag R

    2016-01-01

    Since human urine is the most readily available biofluid whose proteome changes in response to disease, it is a logical sample for identifying protein biomarkers for kidney diseases. Potential biomarkers were identified by using a multiproteomics workflow to compare urine proteomes of kidney transplant patients with immediate and delayed graft function. Differentially expressed proteins were identified, and corresponding stable isotope labeled internal peptide standards were synthesized for scheduled MRM. The Targeted Urine Proteome Assay (TUPA) was then developed by identifying those peptides for which there were at least two transitions for which interference in a urine matrix across 156 MRM runs was <30%. This resulted in an assay that monitors 224 peptides from 167 quantifiable proteins. TUPA opens the way for using a robust mass spectrometric technology, MRM, for quantifying and validating biomarkers from among 167 urinary proteins. This approach, while developed using differentially expressed urinary proteins from patients with delayed versus immediate graft function after kidney transplant, can be expanded to include differentially expressed urinary proteins in multiple kidney diseases. Thus, TUPA could provide a single assay to help diagnose, prognose, and manage many kidney diseases. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. First evidence of subclinical renal tubular injury during sickle-cell crisis.

    PubMed

    Audard, Vincent; Moutereau, Stéphane; Vandemelebrouck, Gaetana; Habibi, Anoosha; Khellaf, Mehdi; Grimbert, Philippe; Levy, Yves; Loric, Sylvain; Renaud, Bertrand; Lang, Philippe; Godeau, Bertrand; Galactéros, Frédéric; Bartolucci, Pablo

    2014-04-29

    The pathophysiologic mechanisms classically involved in sickle-cell nephropathy include endothelial dysfunction and vascular occlusion. Arguments demonstrating that ischemia-reperfusion injury-related kidney damage might coincide with vaso-occlusive crisis (VOC) are lacking. In this prospective study, we sought to determine whether tubular cells and glomerular permeability might be altered during VOC. Urine neutrophil gelatinase-associated lipocalin (NGAL) levels and albumin-excretion rates (AER) of 25 patients were evaluated prospectively during 25 VOC episodes and compared to their steady state (ST) values. During VOC, white blood-cell counts (WBC) and C-reactive protein (CRP) were significantly higher than at ST but creatinine levels were comparable. Urine NGAL levels were significantly increased during VOC vs ST (P = 0.007) and remained significant when normalized to urine creatinine (P = 0.004), while AER did not change significantly. The higher urine NGAL concentration was not associated with subsequent (24-48 hour) acute kidney injury. Univariate analysis identified no significant correlations between urine NGAL levels and laboratory parameters during VOC. These results demonstrated that subclinical ischemia-reperfusion tubular injury is common during VOC and highlight the importance of hydroelectrolyte monitoring and correction during VOC.

  16. Non-invasive prediction of recurrence in bladder cancer by detecting somatic TERT promoter mutations in urine.

    PubMed

    Descotes, Françoise; Kara, Norelyakin; Decaussin-Petrucci, Myriam; Piaton, Eric; Geiguer, Florence; Rodriguez-Lafrasse, Claire; Terrier, Jean E; Lopez, Jonathan; Ruffion, Alain

    2017-08-08

    Urothelial bladder cancer (UBC) is characterised by a high risk of recurrence. Patient monitoring is currently based on iterative cystoscopy and on urine cytology with low sensitivity in non-muscle-invasive bladder cancer (NMIBC). Telomerase reverse transcriptase (TERT) is frequently reactivated in UBC by promoter mutations. We studied whether detection of TERT mutation in urine could be a predictor of UBC recurrence and compared this to cytology/cystoscopy for patient follow-up. A total of 348 patients treated by transurethral bladder resection for UBC were included together with 167 control patients. Overall sensitivity was 80.5% and specificity 89.8%, and was not greatly impacted by inflammation or infection. TERT remaining positive after initial surgery was associated with residual carcinoma in situ. TERT in urine was a reliable and dynamic predictor of recurrence in NMIBC (P<0.0001). In univariate analysis, TERT positive-status after initial surgery increased risk of recurrence by 5.34-fold (P=0.0004). TERT positive-status was still associated with recurrence in the subset of patients with negative cystoscopy (P=0.034). TERT mutations in urine might be helpful for early detection of recurrence in UBC, especially in NMIBC.

  17. Quantifying creatinine and urea in human urine through Raman spectroscopy aiming at diagnosis of kidney disease

    NASA Astrophysics Data System (ADS)

    Saatkamp, Cassiano Junior; de Almeida, Maurício Liberal; Bispo, Jeyse Aliana Martins; Pinheiro, Antonio Luiz Barbosa; Fernandes, Adriana Barrinha; Silveira, Landulfo, Jr.

    2016-03-01

    Due to their importance in the regulation of metabolites, the kidneys need continuous monitoring to check for correct functioning, mainly by urea and creatinine urinalysis. This study aimed to develop a model to estimate the concentrations of urea and creatinine in urine by means of Raman spectroscopy (RS) that could be used to diagnose kidney disease. Midstream urine samples were obtained from 54 volunteers with no kidney complaints. Samples were subjected to a standard colorimetric assay of urea and creatinine and submitted to spectroscopic analysis by means of a dispersive Raman spectrometer (830 nm, 350 mW, 30 s). The Raman spectra of urine showed peaks related mainly to urea and creatinine. Partial least squares models were developed using selected Raman bands related to urea and creatinine and the biochemical concentrations in urine measured by the colorimetric method, resulting in r=0.90 and 0.91 for urea and creatinine, respectively, with root mean square error of cross-validation (RMSEcv) of 312 and 25.2 mg/dL, respectively. RS may become a technique for rapid urinalysis, with concentration errors suitable for population screening aimed at the prevention of renal diseases.

  18. Temporary Urine and Brine Stowage System (TUBSS) Materials Selection and Testing

    NASA Technical Reports Server (NTRS)

    Carrigan, Caitlin; Dries, Kevin; Pensinger, Stuart

    2011-01-01

    Storing wastewater in the event of a system anomaly is a necessity for closed loop water recovery systems. The temporary urine and brine stowage system (TUBSS) is an assembly used to store and transfer pre-treated urine (PTU) and brine for processing or disposal at a later date. This paper describes the selection and testing of several candidate materials from both a chemical and material strength standpoint. In addition, this paper will provide results of testing as well as lessons learned from the project, culminating in the successful launch of the hardware.

  19. Deuterium: Natural variations used as a biological tracer

    USGS Publications Warehouse

    Gleason, J.D.; Friedman, I.

    1970-01-01

    The suggestion is made that isotope tracing be carried out by monitoring the natural variations in deuterium concentrations. As an example, the natural variations in deuterium concentrations between food and water collected in Illinois and food and water collected in Colorado were used to determine the residence time of water in the blood and urine of rats. We observed not only a 51/2-day turnover time of water in the blood and urine, but also evidence for the influx of water vapor from the atmosphere through the lungs into the blood.

  20. Potentialities of mass spectrometry (ICP-MS) for actinides determination in urine.

    PubMed

    Bouvier-Capely, C; Ritt, J; Baglan, N; Cossonnet, C

    2004-05-01

    The applicability of inductively coupled plasma-mass spectrometry (ICP-MS) for determining actinides in urine was investigated. Performances of ICP-MS including detection limit and analysis time were studied and compared with alpha spectrometry performances. In the field of individual monitoring of workers, the comparison chart obtained in this study can be used as a guide for medical laboratories to select the most adequate procedure to be carried out depending on the case in question (the radioisotope to be measured, the required sensitivity, and the desired response time).

  1. Nonhazardous Urine Pretreatment Method

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Holtsnider, John T.

    2012-01-01

    A method combines solid phase acidification with two non-toxic biocides to prevent ammonia volatilization and microbial proliferation. The safe, non-oxidizing biocide combination consists of a quaternary amine and a food preservative. This combination has exhibited excellent stabilization of both acidified and unacidified urine. During pretreatment tests, composite urine collected from donors was challenged with a microorganism known to proliferate in urine, and then was processed using the nonhazardous urine pre-treatment method. The challenge microorganisms included Escherichia coli, a common gram-negative bacteria; Enterococcus faecalis, a ureolytic gram-positive bacteria; Candida albicans, a yeast commonly found in urine; and Aspergillus niger, a problematic mold that resists urine pre-treatment. Urine processed in this manner remained microbially stable for over 57 days. Such effective urine stabilization was achieved using non-toxic, non-oxidizing biocides at higher pH (3.6 to 5.8) than previous methods in use or projected for use aboard the International Space Station (ISS). ISS urine pretreatment methods employ strong oxidants including ozone and hexavalent chromium (Cr(VI)), a carcinogenic material, under very acidic conditions (pH = 1.8 to 2.4). The method described here offers a much more benign chemical environment than previous pretreatment methods, and will lower equivalent system mass (ESM) by reducing containment volume and mass, system complexity, and crew time needed to handle pre-treatment chemicals. The biocides, being non-oxidizing, minimize the potential for chemical reactions with urine constituents to produce volatile, airborne contaminants such as cyanogen chloride. Additionally, the biocides are active under significantly less acidic conditions than those used in the current system, thereby reducing the degree of required acidification. A simple flow-through solid phase acidification (SPA) bed is employed to overcome the natural buffering capacity of urine, and to lower the pH to levels that fix ammoniacal nitrogen in the non-volatile and highly water soluble NH4 + form. Citric acid, a highly soluble, solid tricarboxylic acid essential to cellular metabolism, and typically used as a food preservative, has also been shown to efficiently acidify urine in conjunction with non-oxidizing biocides to provide effective stabilization with respect to both microbial growth and ammonia volatilization.

  2. Determination of caprolactam and 6-aminocaproic acid in human urine using hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    PubMed

    Wu, Ya-Hsueh; Wu, Ming-Ling; Lin, Chun-Chi; Chu, Wei-Lan; Yang, Chen-Chang; Lin, Robert Tate; Deng, Jou-Fang

    2012-02-15

    A simple and rapid assay based on hydrophilic interaction liquid chromatography with tandem mass spectrometry has been first developed and validated for simultaneous determination of caprolactam (CA) and 6-aminocaproic acid (6-ANCA) in human urine using 8-aminocaprylic acid as internal standard. A 20μL aliquot of urine was injected directly into the liquid chromatography tandem mass spectrometry (LC-MS-MS) system. The analytes were separated on a Phenomenex Luna HILIC column with gradient elution. Detection was performed on Triple Quadrupole LC-MS in positive ions multiple reaction monitoring mode using electrospray ionization. The calibration curves were linear (r(2)≥0.995) over the concentration range from 62.5 to 1250ng/mL for CA and 31.25 to 1000ng/mL for 6-ANCA. The detection limits of CA and 6-ANCA were 62.5 and 15.6ng/mL, respectively. The intra-day and inter-day precisions were within 8.7% and 9.9%, respectively. The intra-day and inter-day accuracy were between 5.3% and 3.5%, and between 6.1% and 6.6%, respectively. The method proved to be simple and time efficient, and was successfully applied to evaluate the kinetics of caprolactam in one unusual case of caprolactam poisoning. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Detection of novel metabolites of flaxseed lignans in vitro and in vivo.

    PubMed

    Quartieri, Andrea; García-Villalba, Rocío; Amaretti, Alberto; Raimondi, Stefano; Leonardi, Alan; Rossi, Maddalena; Tomàs-Barberàn, Francisco

    2016-07-01

    This study aimed to improve the knowledge of secoisolariciresinol diglucoside (SDG) transformation by human gut microbiota. SDG-supplemented microbiota cultures were inoculated with the feces of five subjects. The same volunteers received a flaxseed supplement for 7 days. SDG metabolites in cultures, feces, and urine were monitored by LC-ESI-QTOF and LC-DAD. In all cultures, SDG was deglycosylated to secoisolariciresinol (SECO) within 12 h. SECO underwent successive dehydroxylations and demethylations yielding enterodiol (4-18% conversion) and enterolactone (0.2-6%) after 24 h. Novel intermediates related to SECO, matairesinol (MATA), and anhydrosecoisolariciresinol (AHS) were identified in fecal cultures. These metabolites were also found after flaxseed consumption in feces and urine (in approximate amounts between 0.01-47.03 μg/g and 0.01-13.49 μg/mL, respectively) in their native form and/or modified by phase II human enzymes (glucuronide, sulfate and sulfoglucuronide conjugates). Derivatives of MATA and AHS are described for the first time as intermediates of SDG biotransformation by intestinal bacteria, providing a more comprehensive knowledge of lignan intestinal metabolism. The transformations observed in vitro seem to occur in vivo as well. The detection in urine of SDG intermediates indicates their gut absorption, opening new perspectives on the study of their systemic biological effects. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Extended testing of compression distillation.

    NASA Technical Reports Server (NTRS)

    Bambenek, R. A.; Nuccio, P. P.

    1972-01-01

    During the past eight years, the NASA Manned Spacecraft Center has supported the development of an integrated water and waste management system which includes the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water, and concentrated wash water. This paper describes the design of the compression distillation unit, developed for this system, and the testing performed to demonstrate its reliability and performance. In addition, this paper summarizes the work performed on pretreatment and post-treatment processes, to assure the recovery of sterile potable water from urine and treated urinal flush water.

  5. The further development of the active urine collection device: a novel continence management system.

    PubMed

    Tinnion, E; Jowitt, F; Clarke-O'Neill, S; Cottenden, A M; Fader, M; Sutherland, I

    2003-01-01

    Continence difficulties affect the lives of a substantial minority of the population. Women are far more likely than men to be affected by urinary incontinence but the range of management options for them is limited. There has been considerable interest in developing an external urine collection system for women but without success to date. This paper describes the development and preliminary clinical testing of an active urine collection device (AUCD), which could provide a solution for sufferers. The device uses stored vacuum, protected by a high bubble point filter, to remove urine as quickly as it is produced. This allows a small battery-operated pump to provide the required vacuum, enabling the device to be portable. Two different types of non-invasive patient/device interface were developed, and tested by volunteers: urinal and small pad. The slimline urinal was popular with users although liquid noise was a problem. The pad interface was successful on occasions but further work is necessary to produce a reliable pad. This study has successfully demonstrated that a prototype AUCD liquid handling system can remove urine at clinically relevant flowrates. While further development is required, volunteer tests have shown that the AUCD could be a useful advance in continence management.

  6. Intensive Monitoring of Urine Output Is Associated With Increased Detection of Acute Kidney Injury and Improved Outcomes.

    PubMed

    Jin, Kui; Murugan, Raghavan; Sileanu, Florentina E; Foldes, Emily; Priyanka, Priyanka; Clermont, Gilles; Kellum, John A

    2017-11-01

    Urine output (UO) is a vital sign for critically ill patients, but standards for monitoring and reporting vary widely between ICUs. Careful monitoring of UO could lead to earlier recognition of acute kidney injury (AKI) and better fluid management. We sought to determine if the intensity of UO monitoring is associated with outcomes in patients with and those without AKI. This was a retrospective cohort study including 15,724 adults admitted to ICUs from 2000 to 2008. Intensive UO monitoring was defined as hourly recordings and no gaps > 3 hours for the first 48 hours after ICU admission. Intensive monitoring for UO was conducted in 4,049 patients (26%), and we found significantly higher rates of AKI (OR, 1.22; P < .001) in these patients. After adjustment for age and severity of illness, intensive UO monitoring was associated with improved survival but only among patients experiencing AKI. With or without AKI, patients with intensive monitoring also had less cumulative fluid volume (2.98 L vs 3.78 L; P < .001) and less fluid overload (2.49% vs 5.68%; P < .001) over the first 72 hours of ICU stay. In this large ICU population, intensive monitoring of UO was associated with improved detection of AKI and reduced 30-day mortality in patients experiencing AKI, as well as less fluid overload for all patients. Our results should help inform clinical decisions and ICU policy about frequency of monitoring of UO, especially for patients at high risk of AKI or fluid overload, or both. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Estimating the population distribution of usual 24-hour sodium excretion from timed urine void specimens using a statistical approach accounting for correlated measurement errors.

    PubMed

    Wang, Chia-Yih; Carriquiry, Alicia L; Chen, Te-Ching; Loria, Catherine M; Pfeiffer, Christine M; Liu, Kiang; Sempos, Christopher T; Perrine, Cria G; Cogswell, Mary E

    2015-05-01

    High US sodium intake and national reduction efforts necessitate developing a feasible and valid monitoring method across the distribution of low-to-high sodium intake. We examined a statistical approach using timed urine voids to estimate the population distribution of usual 24-h sodium excretion. A sample of 407 adults, aged 18-39 y (54% female, 48% black), collected each void in a separate container for 24 h; 133 repeated the procedure 4-11 d later. Four timed voids (morning, afternoon, evening, overnight) were selected from each 24-h collection. We developed gender-specific equations to calibrate total sodium excreted in each of the one-void (e.g., morning) and combined two-void (e.g., morning + afternoon) urines to 24-h sodium excretion. The calibrated sodium excretions were used to estimate the population distribution of usual 24-h sodium excretion. Participants were then randomly assigned to modeling (n = 160) or validation (n = 247) groups to examine the bias in estimated population percentiles. Median bias in predicting selected percentiles (5th, 25th, 50th, 75th, 95th) of usual 24-h sodium excretion with one-void urines ranged from -367 to 284 mg (-7.7 to 12.2% of the observed usual excretions) for men and -604 to 486 mg (-14.6 to 23.7%) for women, and with two-void urines from -338 to 263 mg (-6.9 to 10.4%) and -166 to 153 mg (-4.1 to 8.1%), respectively. Four of the 6 two-void urine combinations produced no significant bias in predicting selected percentiles. Our approach to estimate the population usual 24-h sodium excretion, which uses calibrated timed-void sodium to account for day-to-day variation and covariance between measurement errors, produced percentile estimates with relatively low biases across low-to-high sodium excretions. This may provide a low-burden, low-cost alternative to 24-h collections in monitoring population sodium intake among healthy young adults and merits further investigation in other population subgroups. © 2015 American Society for Nutrition.

  8. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  9. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  10. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  11. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  12. Comparative Evaluation of Three Nucleic Acid-Based Assays for BK Virus Quantification

    PubMed Central

    Descamps, Veronique; Martin, Elodie; Morel, Virginie; François, Catherine; Helle, François; Duverlie, Gilles; Castelain, Sandrine

    2015-01-01

    With the growing importance of BK virus (BKV), effective and efficient screening for BKV replication in plasma and urine samples is very important for monitoring renal transplant and hematopoietic stem cell transplant recipients, who are at increased risk of BKV-associated diseases. However, recent assays proposed by many manufacturers have not been tested, and the available tests have not been standardized. The aim of the present study was to evaluate and compare the performances of three commercially available kits, R-gene, GeneProof, and RealStar, on plasma and urine specimens from patients infected with various genotypes and to determine the correlations with the results from a reference laboratory. A qualitatively excellent global agreement (96.8%) was obtained. RealStar PCR tended to give a higher sensitivity, especially for subtype Ib1 samples. Comparison of 30 plasma samples and 53 urine samples showed a good agreement between the three assays, with Spearman's Rho correlation coefficient values falling between 0.92 and 0.98 (P < 0.001). Moreover, a perfect correlation was obtained for comparison of the assay performances with the AcroMetrix BKV panel (P < 0.001 for all comparisons). According to Bland-Altman analysis, more than 95% (240/249 comparisons) of sample comparisons were situated in the range of the mean ± 2 standard deviations (SD). The greatest variability between assays was observed for 10.2% of subtype Ib2 samples, with differences of >1 log10 copies/ml. In conclusion, this study demonstrated the reliable and comparable performances of the R-gene, GeneProof, and RealStar real-time PCR systems for quantification of BKV in urine and plasma samples. All three real-time PCR assays are appropriate for screening of BKV replication in patients. PMID:26424842

  13. Development of SPME-LC-MS method for screening of eight beta-blockers and bronchodilators in plasma and urine samples.

    PubMed

    Goryński, Krzysztof; Kiedrowicz, Alicja; Bojko, Barbara

    2016-08-05

    The current work describes the development and validation of a simple, efficient, and fast method using solid phase microextraction coupled to liquid chromatography-tandem mass spectrometry (SPME-LC-MS/MS) for the concomitant measurement of eight beta-blockers and bronchodilators in plasma and urine. The presented assay enables quantitative determination of acebutolol, atenolol, fenoterol, nadolol, pindolol, procaterol, sotalol, and timolol. In this work, samples were prepared on a high-throughput platform using the 96-well plate format of the thin film solid phase microextraction (TFME) system, and a biocompatible extraction phase made of hydrophilic-lipophilic balance particles. Analytes were separated on a pentafluorophenyl column (100mm×2.1mm, 3μm) by gradient elution using an UPLC Nexera coupled with an LCMS-8060 mass spectrometer. The mobile phase consisted of water-acetonitrile (0.1% formic acid) at a flow rate of 0.4mLmin(-1). The linearity of the method was checked within therapeutic blood-plasma concentrations, and shown to adequately reflect typically expected concentrations of future study samples. Post-extraction addition experiments showed that the matrix effect ranged in plasma from 98% for procaterol to 115% for nadolol, and in urine, from 85% for nadolol and pindolol to 119% for atenolol. The method was successfully validated using Food and Drug Administration (FDA) guidelines, and met all acceptance criteria for bioanalytical assays at five concentration levels for all selected drugs. The final protocol can be successfully applied for monitoring concentrations of the selected drugs in both plasma and urine matrices obtained from patients or athletes. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Using microRNA profiling in urine samples to develop a non-invasive test for bladder cancer.

    PubMed

    Mengual, Lourdes; Lozano, Juan José; Ingelmo-Torres, Mercedes; Gazquez, Cristina; Ribal, María José; Alcaraz, Antonio

    2013-12-01

    Current standard methods used to detect and monitor bladder urothelial cell carcinoma (UCC) are invasive or have low sensitivity. The incorporation into clinical practice of a non-invasive tool for UCC assessment would enormously improve patients' quality of life and outcome. This study aimed to examine the microRNA (miRNA) expression profiles in urines of UCC patients in order to develop a non-invasive accurate and reliable tool to diagnose and provide information on the aggressiveness of the tumor. We performed a global miRNA expression profiling analysis of the urinary cells from 40 UCC patients and controls using TaqMan Human MicroRNA Array followed by validation of 22 selected potentially diagnostic and prognostic miRNAs in a separate cohort of 277 samples using a miRCURY LNA qPCR system. miRNA-based signatures were developed by multivariate logistic regression analysis and internally cross-validated. In the initial cohort of patients, we identified 40 and 30 aberrantly expressed miRNA in UCC compared with control urines and in high compared with low grade tumors, respectively. Quantification of 22 key miRNAs in an independent cohort resulted in the identification of a six miRNA diagnostic signature with a sensitivity of 84.8% and specificity of 86.5% (AUC = 0.92) and a two miRNA prognostic model with a sensitivity of 84.95% and a specificity of 74.14% (AUC = 0.83). Internal cross-validation analysis confirmed the accuracy rates of both models, reinforcing the strength of our findings. Although the data needs to be externally validated, miRNA analysis in urine appears to be a valuable tool for the non-invasive assessment of UCC. Copyright © 2013 UICC.

  15. Polyomavirus BK and JC in individuals with chronic kidney failure, kidney transplantation, and healthy controls.

    PubMed

    Castro, Talita; Fink, Maria Cristina Domingues; Figueiredo, Marilia; Braz-Silva, Paulo Henrique; Pannuti, Cláudio Mendes; Ortega, Karem Lopez; Gallottini, Marina

    2017-04-01

    New clinical approaches to diagnose and monitor individuals with systemic diseases have been employed through the use of oral fluids. Polyomavirus BK (BKPyV) and JC (JCPyV) infect asymptomatically around 80% of general population worldwide remaining latent in the body. In case of immunosuppression, a replication can occur, leading to diseases. The aim of this study was to detect and quantify BKPyV and JCPyV in oral fluids of individuals with chronic kidney failure (CKF), kidney transplantation (KT) and controls compared with their detection in blood and urine, traditionally used for this test. Forty six subjects were included and distributed into 3 groups: 14 with CKF (Group 1), 12 with KT (Group 2) and 20 healthy individuals (Group 3). In a total, 315 samples were collected and analyzed through RT-PCR, being 151 of gingival crevicular fluid, 46 of saliva, 46 of mouthwash, 43 of blood and 29 of urine. All subjects from group 1 were positive for BKPyV in at least one collected samples and 14% were positive for JCPyV. In Group 2, 91.7% were positive for BKPyV and 51.7% for JCPyV. Among subjects of Group 3, 80% were positive for BKPyV and 45% for JCPyV. Oral fluids exhibited high prevalence of BKPyV and JCPyV and were equally efficient compared to urine and blood. The use of oral fluids to detect these polyomaviruses enhances positivity in screening, even in cases of absence of viremia and especially in individuals who are not able to urinate. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Urine temperature as an index for the core temperature of industrial workers in hot or cold environments

    NASA Astrophysics Data System (ADS)

    Kawanami, Shoko; Horie, Seichi; Inoue, Jinro; Yamashita, Makiko

    2012-11-01

    Workers working in hot or cold environments are at risk for heat stroke and hypothermia. In Japan, 1718 people including 47 workers died of heat stroke in 2010 (Ministry of Health Labour and Welfare, Japan 2011). While the American Conference of Governmental Industrial Hygienists (ACGIH) recommendation lists the abnormal core temperature of workers as a criterion for halting work, no method has been established for reliably measuring core temperatures at workplaces. ISO 9886 (Ergonomics-evaluation of thermal strain by physiological measurements. ISO copyright office, Geneva, pp 3-14; 2004) recognizes urine temperature as an index of core temperature only at normal temperature. In this study we ascertained whether or not urine temperature could serve as an index for core temperature at temperatures above and below the ISO range. We measured urine temperature of 31 subjects (29.8 ± 11.9 years) using a thermocouple sensor placed in the toilet bowl at ambient temperature settings of 40, 20, and 5˚C, and compared them with rectal temperature. At all ambient temperature settings, urine temperature correlated closely with rectal temperature exhibiting small mean bias. Urine temperature changed in a synchronized manner with rectal temperature at 40˚C. A Bland and Altman analysis showed that the limits of agreement (mean bias ± 2SD) between rectal and urine temperatures were -0.39 to +0.15˚C at 40˚C (95%CI -0.44 to +0.20˚C) and -0.79 to +0.29˚C at 5˚C (-0.89 to +0.39˚C). Hence, urine temperature as measured by the present method is a practical surrogate index for rectal temperature and represents a highly reliable biological monitoring index for assessing hot and cold stresses of workers at actual workplaces.

  17. Urine flow is a novel hemodynamic monitoring tool for the detection of hypovolemia.

    PubMed

    Shamir, Micha Y; Kaplan, Leonid; Marans, Rachel S; Willner, Dafna; Klein, Yoram

    2011-03-01

    Noticeable changes in vital signs indicating hypovolemia occur only after 15% of the blood volume is lost. More sensitive variables (e.g., cardiac output, systolic pressure variation and its Δdown component) are invasive and difficult to obtain in the early phase of bleeding. Lately, a new technology for continuous optical measurements of minute-to-minute urine flow rates has become available. We performed a preliminary evaluation to determine whether urine flow can act as an early and sensitive warning of hypovolemia. Eleven patients (ASA physical status I-II) undergoing posterior spine fusion surgery were studied prospectively. Study variables included heart rate, blood pressure (systolic and diastolic), systolic pressure variation and Δdown, minute urinary flow, hemoglobin, blood and urinary sodium, and creatinine in the blood and urine. Urine flow rate was measured using URINFO 2000™ (FlowSense Medical, Misgav, Israel). After recording baseline variables, 10 mL/kg of the patient's blood was shed and a second set of variables was recorded. Subsequently, hypovolemia was reversed by infusing colloid solution (hetastarch 6%) followed by recording a third set of variables. These 3 observations were then compared. An average of 614 ± 143 mL (mean ± SD) of blood was shed. During phlebotomy, the mean urine flow rate decreased from 5.7 ± 8 mL/min to 1.07 ± 2.5 mL/min. Systolic blood pressure and hemoglobin also decreased. Δdown increased. After rehydration, urine flow, blood pressure, and Δdown values returned to baseline. The hemoglobin concentration decreased whereas other variables did not change significantly. Urine flow rate is a dynamic variable that seems to be a reliable indicator of changes in blood volume. These results justify further investigation.

  18. The rate of aucubin, a secondary metabolite in Plantago lanceolata and potential nitrification inhibitor, needed to reduce ruminant urine patch nitrous oxide emissions

    NASA Astrophysics Data System (ADS)

    Gardiner, C. A.; Clough, T.; Cameron, K.; Di, H.; Edwards, G. R.

    2017-12-01

    Nitrous oxide (N2O) losses derived from grazing ruminant livestock urine patches account for 40% of global N2O emissions. It has been shown that Plantago lanceolata, an herb species used in grazed pastures, contains an active secondary metabolite (aucubin) that has the potential to be excreted by grazing ruminants and inhibit nitrification in the urine patch, a key step in soil N2O production. However, the urinary excretion rate of aucubin needed to significantly reduce urine patch N2O emissions remains unknown. Aucubin was dissolved in bovine urine at three rates (47, 243, and 486 kg ha-1), based on rates used in Dietz et al. (2013) and the calculated highest potential aucubin application rate, from Gardiner et al. (2017). A control, along with a urine treatment and the three aucubin treatments (all urine applied at 700 kg N ha-1), was applied to 20 g soil and incubated in the laboratory for 35 d. Soils were monitored for surface pH, inorganic N concentration (NH4+/NO3-), and gas (N2O and CO2) fluxes. This experiment is currently underway and the results will be presented at the conference. Dietz M, Machill S, Hoffmann H, Schmidtke K 2013. Inhibitory effects of Plantago lanceolata L. on soil N mineralization. Plant and Soil 368: 445-458. Gardiner CA, Clough TJ, Cameron KC, Di HJ, Edwards GR, de Klein CAM 2017. The potential inhibitory effects of Plantago lanceolata and its active secondary metabolite aucubin on soil nitrification and nitrous oxide emissions under ruminant urine patch conditions. Manuscript submitted for publication.

  19. Temporal variability of pyrethroid metabolite levels in bedtime, morning, and 24-h urine samples for 50 adults in North Carolina.

    PubMed

    Morgan, Marsha K; Sobus, Jon R; Barr, Dana Boyd; Croghan, Carry W; Chen, Fu-Lin; Walker, Richard; Alston, Lillian; Andersen, Erik; Clifton, Matthew S

    2016-01-01

    Pyrethroid insecticides are widely used to control insects in both agricultural and residential settings worldwide. Few data are available on the temporal variability of pyrethroid metabolites in the urine of non-occupationally exposed adults. In this work, we describe the study design and sampling methodology for the Pilot Study to Estimate Human Exposures to Pyrethroids using an Exposure Reconstruction Approach (Ex-R study). Two major objectives were to quantify the concentrations of several pyrethroid metabolites in bedtime, first morning void (FMV), and 24-h urine samples as concentration (wet weight), specific-gravity (SG) corrected, creatinine (CR) corrected, and excretion rate values for 50 Ex-R adults over a six-week monitoring period and to determine if these correction approaches for urine dilution reduced the variability of the biomarker levels. The Ex-R study was conducted at the United States Environmental Protection Agency's Human Studies Facility in Chapel Hill, North Carolina USA and at participants' homes within a 40-mile radius of this facility. Recruitment of participants and field activities occurred between October 2009 and May 2011. Participants, ages 19-50 years old, provided daily food, activity, and pesticide-use diaries and collected their own urine samples (bedtime, FMV, and 24-h) during weeks 1, 2, and 6 of a six-week monitoring period. A total of 2503 urine samples were collected from the study participants. These samples were analyzed for the pyrethroid metabolites 3-phenoxybenzoic acid (3-PBA), cis/trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-cyclopropane carboxylic acid (cis/trans-DCCA), and 2-methyl-3-phenylbenzoic acid (MPA) using high performance liquid chromatography/tandem mass spectrometry. Only 3-PBA was frequently detected (>50%) in the adult urine samples. Median urinary 3-PBA levels were 0.88 ng/mL, 0.96 ng/mL-SG, 1.04 ng/mg, and 1.04 ng/min for concentration, SG-corrected, CR-corrected, and excretion rate values, respectively, across all urine samples. The results showed that median urinary 3-PBA concentrations were consistently the lowest in FMV samples (0.77 ng/mL, 0.68 ng/mL-SG, 0.68 ng/mg, and 0.58 ng/min) and the highest in 24-h samples (0.92 ng/mL, 1.06 ng/mL-SG, 1.18 ng/mg, and 1.19 ng/min) across all four methods. Intraclass correlation coefficient (ICC) estimates for 3-PBA indicated poor reproducibility (<0.22) for all urine sample types and methods over a day, week, and six weeks. Correcting for urine sample dilution, based on either SG, CR or urine output, introduced additional measurement variability both between- and within-individuals. These results indicate that a single measure of urinary 3-PBA was not sufficient to characterize average exposure regardless of sample type, correction method, and time frame of collection. In addition, the study results can be used to inform the design of exposure characterization strategies in relevant environmental epidemiology studies in the future. Published by Elsevier Inc.

  20. Biological monitoring results for cadmium exposed workers.

    PubMed

    McDiarmid, M A; Freeman, C S; Grossman, E A; Martonik, J

    1996-11-01

    As part of a settlement agreement with the Occupational Safety and Health Administration (OSHA) involving exposure to cadmium (Cd), a battery production facility provided medical surveillance data to OSHA for review. Measurements of cadmium in blood, cadmium in urine, and beta 2-microglobulin in urine were obtained for more than 100 workers over an 18-month period. Some airborne Cd exposure data were also made available. Two subpopulations of this cohort were of primary interest in evaluating compliance with the medical surveillance provisions of the Cadmium Standard. These were a group of 16 workers medically removed from cadmium exposure due to elevations in some biological parameter, and a group of platemakers. Platemaking had presented a particularly high exposure opportunity and had recently undergone engineering interventions to minimize exposure. The effect on three biological monitoring parameters of medical removal protection in the first group and engineering controls in platemakers is reported. Results reveal that both medical removal from cadmium exposures and exposure abatement through the use of engineering and work practice controls generally result in declines in biological monitoring parameters of exposed workers. Implications for the success of interventions are discussed.

  1. Multi-targeted interference-free determination of ten β-blockers in human urine and plasma samples by alternating trilinear decomposition algorithm-assisted liquid chromatography-mass spectrometry in full scan mode: comparison with multiple reaction monitoring.

    PubMed

    Gu, Hui-Wen; Wu, Hai-Long; Yin, Xiao-Li; Li, Yong; Liu, Ya-Juan; Xia, Hui; Zhang, Shu-Rong; Jin, Yi-Feng; Sun, Xiao-Dong; Yu, Ru-Qin; Yang, Peng-Yuan; Lu, Hao-Jie

    2014-10-27

    β-blockers are the first-line therapeutic agents for treating cardiovascular diseases and also a class of prohibited substances in athletic competitions. In this work, a smart strategy that combines three-way liquid chromatography-mass spectrometry (LC-MS) data with second-order calibration method based on alternating trilinear decomposition (ATLD) algorithm was developed for simultaneous determination of ten β-blockers in human urine and plasma samples. This flexible strategy proved to be a useful tool to solve the problems of overlapped peaks and uncalibrated interferences encountered in quantitative LC-MS, and made the multi-targeted interference-free qualitative and quantitative analysis of β-blockers in complex matrices possible. The limits of detection were in the range of 2.0×10(-5)-6.2×10(-3) μg mL(-1), and the average recoveries were between 90 and 110% with standard deviations and average relative prediction errors less than 10%, indicating that the strategy could provide satisfactory prediction results for ten β-blockers in human urine and plasma samples only using liquid chromatography hyphenated single-quadrupole mass spectrometer in full scan mode. To further confirm the feasibility and reliability of the proposed method, the same batch samples were analyzed by multiple reaction monitoring (MRM) method. T-test demonstrated that there are no significant differences between the prediction results of the two methods. Considering the advantages of fast, low-cost, high sensitivity, and no need of complicated chromatographic and tandem mass spectrometric conditions optimization, the proposed strategy is expected to be extended as an attractive alternative method to quantify analyte(s) of interest in complex systems such as cells, biological fluids, food, environment, pharmaceuticals and other complex samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. The impact of tabalumab on the kidney in systemic lupus erythematosus: results from two phase 3 randomized, clinical trials.

    PubMed

    Rovin, B H; Dooley, M A; Radhakrishnan, J; Ginzler, E M; Forrester, T D; Anderson, P W

    2016-12-01

    Tabalumab is a monoclonal antibody that neutralizes membrane and soluble B-cell activating factor. Two 52-week, randomized, double-blind, placebo controlled phase 3 trials evaluated the safety and efficacy of tabalumab in systemic lupus erythematosus. Patients with moderate to severe active systemic lupus erythematosus (without severe active lupus nephritis) were randomly assigned 1:1:1 to receive tabalumab (120 mg subcutaneously every 2 or 4 weeks) or placebo for 52 weeks. Serum creatinine concentration, estimated glomerular filtration rate, urine protein/creatinine ratio, renal flares and renal adverse events were determined monthly. Data were analyzed for the intent-to-treat population and for intent-to-treat patients with baseline urine protein/creatinine ratio >20 mg/mmol (intent-to-treat plus urine protein/creatinine ratio). The trials enrolled 2262 patients. At baseline, demographics, systemic lupus erythematosus disease activity, serum creatinine concentration, estimated glomerular filtration rate and urine protein/creatinine ratio were similar among the treatment arms (with the exception of disease duration). In the intent-to-treat and intent-to-treat plus urine protein/creatinine ratio populations, there were no differences between the arms in the baseline-to-endpoint change in serum creatinine concentration, glomerular filtration rate, urine protein/creatinine ratio, or renal flare rates. Tabalumab resulted in a significant B-cell reduction and decreased immunoglobulin G levels at both doses. Compared to placebo, tabalumab did not significantly affect the serum creatinine concentration, glomerular filtration rate, urine protein/creatinine ratio, or renal flare rates over 1 year in intent-to-treat or intent-to-treat plus urine protein/creatinine ratio patients. There were no significant renal safety signals.ClinicalTrials.gov identifiers: NCT01205438 and NCT01196091 Lupus (2016) 25, 1597-1601. © The Author(s) 2016.

  3. Dual Fan Separator within the Universal Waste Management System

    NASA Technical Reports Server (NTRS)

    Stapleton, Tom; Converse, Dave; Broyan, James Lee, Jr.

    2014-01-01

    Since NASA's new spacecraft in development for both LEO and Deep Space capability have considerable crew volume reduction in comparison to the Space Shuttle, it is clear that NASA requires a smaller and less expensive commode. The UTAS Universal Waste Management System (UWMS) was designed to address these new constraints, resulting in an 80% volume reduction in the cabin while enhancing performance. Whereas all of the current space commodes use air flow to capture both urine and feces and separate air from the captured air/urine mixture, the UWMS commode and urine fans and the urine separator were combined into a single unit. This unit enables use of a single motor and motor controller, which provides considerable packaging and weight efficiency. In some of the intended platform applications for the UWMS, the urine is pumped to a water reclamation system. The ISS Urine Processor Assembly (UPA) system requires delivered urine to include less than 0.25% air inclusion. Air inclusion in centrifugal urine separators is greatly dependent on its rotational speed. To satisfy this requirement, a gear reducer was included, allowing the fans to rotate at a much higher speed than the separator. This new design, the Dual Fan Separator (DFS) has been designed, prototyped and tested. This paper will outline the studies and analysis performed to develop the design configuration for testing. The studies included a configuration trade study, dynamic stability analysis of the rotating bodies and a performance analysis of included labyrinth seals. NASA is considereing a program to fly the UWMS aboard the ISS as a flight experiment. The goal of the design activity is to elevate the Technical Readiness Level (TRL) of the Dual Fan Separator and determine if the concept is ready to be included in flight experiment deliverable.

  4. Analytical Method for Pyrethroid Metabolites in Urine of the Non-Occupationally Exposed Population by Gas Chromatography/Mass Spectrometry.

    PubMed

    Yoshida, Toshiaki

    2017-10-01

    Pyrethroids are widely being used as household insecticides or mothproof repellents. An analytical method is described for determination of urinary metabolites as biomarkers for monitoring exposure to the pyrethroids. In total, 11 urinary metabolites, 3-(2-carboxyprop-1-enyl)-2,2-dimethylcyclopropanecarboxylic acid, 3-(2-chloro-3,3,3-trifluoroprop-1-enyl)-2,2-dimethylcyclopropanecarboxylic acid, 3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylic acid, 2,2-dimethyl-3-(2-methylprop-1-enyl)cyclopropanecarboxylic acid, 4-fluoro-3-phenoxybenzoic acid, 4-methoxymethyl-2,3,5,6-tetrafluorobenzly alcohol, 2-methyl-3-phenylbenzoic acid, 4-methyl-2,3,5,6-tetrafluorobenzyl alcohol, 3-phenoxybenzoic acid, 2,3,5,6-tetrafluorobenzoic acid and 2,2,3,3-tetramethylcyclopropanecarboxylic acid, were enzymatically hydrolyzed and extracted with toluene. After transformation to their tert-butyldimethylsilyl or trimethylsilyl derivatives, they were analyzed by gas chromatography/mass spectrometry in electron impact ionization mode. The calibration curves for the metabolite were linear over the concentration range of 0-30 μg/L in urine. They could be determined accurately and precisely (detection limits: 0.01-0.12 μg/L, quantification limits: 0.04-0.41 μg/L). The urine samples collected could be stored for up to 1 month at -20°C in a freezer. The proposed method was applied to determine urine samples from several health volunteers. The method was considered to be available for monitoring pyrethroid exposure in the general population. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Simultaneous Quantification of Free and Glucuronidated Cannabinoids in Human Urine by Liquid Chromatography-Tandem Mass Spectrometry

    PubMed Central

    Scheidweiler, Karl B.; Desrosiers, Nathalie A.; Huestis, Marilyn A.

    2012-01-01

    Background Cannabis is the most commonly abused drug of abuse and is commonly quantified during urine drug testing. We conducted a controlled drug administration studies investigating efficacy of urinary cannabinoid glucuronide metabolites for documenting recency of cannabis intake and for determining stability of urinary cannabinoids. Methods A liquid chromatography tandem mass spectrometry method was developed and validated quantifying Δ9-tetrahydrocannabinol (THC), 11-hydroxy-THC (11-OH-THC), 11-nor-9-carboxy-THC (THCCOOH), cannabidiol, cannabinol, THC-glucuronide and THCCOOH-glucuronide in 0.5 ml human urine via supported-liquid extraction. Chromatography was performed on an Ultra Biphenyl column with a gradient of 10 mmol/l ammonium acetate, pH 6.15 and 15% methanol in acetonitrile at 0. 4ml/min. Analytes were monitored by positive and negative mode electrospray ionization and multiple reaction monitoring mass spectrometry. Results Linear ranges were 0.5–50 ng/ml for THC-glucuronide, 1–100 ng/ml for THCCOOH, 11-OH-THC and cannabidiol, 2–100 ng/ml for THC and cannabinol, and 5–500 ng/ml for THCCOOH-glucuronide (R2>0.99). Mean extraction efficiencies were 34–73% with analytical recovery (bias) 80.5–118.0% and total imprecision 3.0–10.2% coefficient of variation. Conclusion This method simultaneously quantifies urinary cannabinoids and phase II glucuronide metabolites, and enables evaluation of urinary cannabinoid glucuronides for documenting recency of cannabis intake and cannabinoid stability. The assay is applicable for routine urine cannabinoid testing. PMID:22771478

  6. Monitoring Blood Sugar: The Importance of Checking Blood Sugar Levels

    MedlinePlus

    ... more portable sizes. Other features may include memory storage and the ability to record other information like ... for ketones , chemicals that show up in the urine (pee) and blood after the body breaks down ...

  7. Prednisolone

    MedlinePlus

    ... If you have diabetes, prednisolone may increase your blood sugar level. If you monitor your blood sugar (glucose) at home, test your blood or urine ... frequently than usual. Call your doctor if your blood sugar is high.Do not let anyone else take ...

  8. Results of an Aboriginal community-based renal disease management program incorporating point of care testing for urine albumin:creatinine ratio.

    PubMed

    Shephard, M D S; Allen, G G; Paizis, K; Barbara, J A J; Batterham, M; Vanajek, A

    2006-01-01

    There has been a significant increase in the burden of renal disease among Aboriginal Australians over the past 15 years. Urine albumin:creatinine ratio (ACR) is a well-established marker of microalbuminuria and can be conveniently performed on the DCA 2000 point-of-care testing (POCT) analyser (Bayer Australia; Melbourne, VIC, Australia) with an on-site result available in 7 min. The application of the urine ACR POCT for renal disease risk assessment was pioneered by our group in the Umoona Kidney Project. This article describes the results of the management arm of the Umoona Kidney Project, which used point-of-care urine ACR testing for the first time within a management framework to monitor albuminuria in patients at highest risk of renal disease. The article also examines the analytical quality of POCT results and overall community acceptance of the Umoona Kidney Project. Adults clinically assessed by Flinders Medical Centre renal specialists as being at greatest risk for renal disease were offered the ACE inhibitor (ACEI) perindopril on a voluntary basis. Selected renal markers, including POCT urine ACR (conducted on-site by Umoona's Aboriginal health worker team), plasma electrolytes, urea, creatinine, calculated glomerular filtration rate and blood pressure were measured six monthly. Regular quality control testing was undertaken to monitor the analytical performance of the POCT analyser. A culturally appropriate questionnaire was designed and implemented to assess community satisfaction with the project. In all, 231 patient management consultations were conducted over a two year period, with over 70% of patients having four or more (up to a maximum of eight) consultations; 35 patients (mean age 49.2 [+/-2.3] years, 54% males) participated voluntarily in the management arm. All were overtly hypertensive, hypertensive with other risk factors or had diabetes. The renal status of these patients was followed for a mean of 63 +/- 4.5 weeks. In total, 111 POCT urine ACR tests were performed for patient management (mean 3.2 tests per patient). There was no significant difference in POCT urine ACR in the study period with a median (and inter-quartile range) of 5.7 mg/mmol (1.2-15.2) pre-ACEI and 4.3 mg/mmol (1.3-16.7) post-ACEI treatment (p = 0.50, Wilcoxon signed ranks test). The calculated glomerular filtration rate altered from 110 to 118 mL/min (p = 0.019, paired t-test). There was no change in the group plasma potassium, urea and creatinine. Collectively these results indicate a stabilisation in renal function among the management group. Blood pressure (both lying and standing) fell significantly in the study period. The imprecision for urine ACR quality control POCT conducted during the management program was within nationally and internationally accepted precision goals for urine albumin, creatinine and ACR. Fifty community members completed the satisfaction questionnaire. Three-quarters of respondents felt there were no cultural barriers in providing a urine sample for urine ACR POCT. The management arm of the Umoona Kidney Project was effective in stabilising the renal function and improving the blood pressure of community members identified to be at greatest risk of kidney disease. POCT urine ACR testing can be utilised, not only for community risk assessment, but also for patient management. The Umoona Kidney Project was well accepted by the health service and community members.

  9. Water recovery by catalytic treatment of urine vapor

    NASA Technical Reports Server (NTRS)

    Budininkas, P.; Quattrone, P. D.; Leban, M. I.

    1980-01-01

    The objective of this investigation was to demonstrate the feasibility of water recovery on a man-rated scale by the catalytic processing of untreated urine vapor. For this purpose, two catalytic systems, one capable of processing an air stream containing low urine vapor concentrations and another to process streams with high urine vapor concentrations, were designed, constructed, and tested to establish the quality of the recovered water.

  10. Androgen and androgen metabolite levels in serum and urine of East African chimpanzees (Pan troglodytes schweinfurthii): comparison of EIA and LC-MS analyses.

    PubMed

    Preis, Anna; Mugisha, Lawrence; Hauser, Barbara; Weltring, Anja; Deschner, Tobias

    2011-12-01

    The primary male androgen testosterone (T) is often used as an endocrinological marker to investigate androgen-behaviour interactions in males. In chimpanzees and bonobos, studies investigating the relationship between T levels and dominance rank or aggressive behaviour have revealed contradictory results. The immunoassays used in these studies were originally developed for the measurement of steroids in serum. Their application to non-invasively collected samples, however, can lead to methodological problems due to cross-reacting metabolites, which might occur in urine or faeces but not in blood. The overall aim of this study, therefore, is to clarify whether a T enzyme immunoassay (EIA) is an applicable method to monitor testicular function in adult male chimpanzees. To estimate the impact of cross-reacting androgens on the used T EIA, we compared the results of an EIA measurement with a set of androgen metabolite levels measured by LC-MS. In urine from male chimpanzees, cross-reactivities appear to exist mainly with T and its exclusive metabolites, 5α-dihydrotestosterone (5α-DHT) and 5α-androstanediol (androstanediol). Both urinary and serum T levels of male chimpanzees were significantly higher than female T levels when measured with the T EIA, indicating a reliable measurement of testicular androgens and their exclusive metabolites with the used EIA. In urine from female chimpanzees, the comparison between LC-MS and T EIA results indicated a higher impact of cross-reactions with adrenal androgen metabolites. Therefore, the investigation of urinary T levels in female chimpanzees with a T EIA seems to be problematic. Overall our results show that a T EIA can be a reliable method to monitor testicular function in male chimpanzee urine and that LC-MS is a valuable tool for the validation of immunoassays. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Direct and efficient liquid chromatographic-tandem mass spectrometric method for opiates in urine drug testing - importance of 6-acetylmorphine and reduction of analytes.

    PubMed

    Andersson, Maria; Stephanson, Nikolai; Ohman, Inger; Terzuoli, Tommy; Lindh, Jonatan D; Beck, Olof

    2014-04-01

    Opiates comprise a class of abused drugs that is of primary interest in clinical and forensic urine drug testing. Determination of heroin, codeine, or a multi-drug ingestion is complicated since both heroin and codeine can lead to urinary excretion of free and conjugated morphine. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) offers advantage over gas chromatography-mass spectrometry by simplifying sample preparation but increases the number of analytes. A method based on direct injection of five-fold diluted urine for confirmation of morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, codeine-6-glucuronide and 6-acetylmorphine was validated using LC-MS/MS in positive electrospray mode monitoring two transitions using selected reaction monitoring. The method was applied for the analysis of 3155 unknown urine samples which were positive for opiates in immunochemical screening. A linear response was observed for all compounds in the calibration curves covering more than three orders of magnitude. Cut off was set to 2 ng/ml for 6-acetylmorphine and 150 ng/ml for the other analytes. 6-Acetylmorphine was found to be effective (sensitivity 82%) in detecting samples as heroin intake. Morphine-3-glucuronide and codeine-6-glucuronide was the predominant components of total morphine and codeine, 84% and 93%, respectively. The authors have validated a robust LC-MS/MS method for rapid qualitative and quantitative analysis of opiates in urine. 6-Acetylmorphine has been demonstrated as a sensitive and important parameter for a heroin intake. A possible interpretation strategy to conclude the source of detected analytes was proposed. The method might be further developed by reducing the number of analytes to morphine-3-glucuronide, codeine-6-glucuronide and 6-acetylmorphine without compromising test performance. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Development and Validation of a UPLC-MS/MS Method to Monitor Cephapirin Excretion in Dairy Cows following Intramammary Infusion

    PubMed Central

    Ray, Partha; Knowlton, Katharine F.; Shang, Chao; Xia, Kang

    2014-01-01

    Cephapirin, a cephalosporin antibiotic, is used by the majority of dairy farms in the US. Fecal and urinary excretion of cephapirin could introduce this compound into the environment when manure is land applied as fertilizer, and may cause development of bacterial resistance to antibiotics critical for human health. The environmental loading of cephapirin by the livestock industry remains un-assessed, largely due to a lack of appropriate analytical methods. Therefore, this study aimed to develop and validate a cephapirin quantification method to capture the temporal pattern of cephapirin excretion in dairy cows following intramammary infusion. The method includes an extraction with phosphate buffer and methanol, solid-phase extraction (SPE) clean-up, and quantification using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The LOQ values of the developed method were 4.02 µg kg−1 and 0.96 µg L−1 for feces and urine, respectively. This robust method recovered >60% and >80% cephapirin from spiked blank fecal and urine samples, respectively, with acceptable intra- and inter-day variation (<10%). Using this method, we detected trace amounts (µg kg−1) of cephapirin in dairy cow feces, and cephapirin in urine was detected at very high concentrations (133 to 480 µg L−1). Cephapirin was primarily excreted via urine and its urinary excretion was influenced by day (P = 0.03). Peak excretion (2.69 mg) was on day 1 following intramammary infusion and decreased sharply thereafter (0.19, 0.19, 0.08, and 0.17 mg on day 2, 3, 4, and 5, respectively) reflecting a quadratic pattern of excretion (Quadratic: P = 0.03). The described method for quantification of cephapirin in bovine feces and urine is sensitive, accurate, and robust and allowed to monitor the pattern of cephapirin excretion in dairy cows. This data will help develop manure segregation and treatment methods to minimize the risk of antibiotic loading to the environment from dairy farms. PMID:25375097

  13. Urine testing to monitor the impact of HPV vaccination in Bhutan and Rwanda.

    PubMed

    Franceschi, Silvia; Chantal Umulisa, M; Tshomo, Ugyen; Gheit, Tarik; Baussano, Iacopo; Tenet, Vanessa; Tshokey, Tshokey; Gatera, Maurice; Ngabo, Fidele; Van Damme, Pierre; Snijders, Peter J F; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2016-08-01

    Bhutan (2010) and Rwanda (2011) were the first countries in Asia and Africa to introduce national, primarily school-based, human papillomavirus (HPV) vaccination programmes. These target 12 year-old girls and initially included catch-up campaigns (13-18 year-olds in Bhutan and ninth school grade in Rwanda). In 2013, to obtain the earliest indicators of vaccine effectiveness, we performed two school-based HPV urine surveys; 973 female students (median age: 19 years, 5th-95th percentile: 18-22) were recruited in Bhutan and 912 (19 years, 17-20) in Rwanda. Participants self-collected a first-void urine sample using a validated protocol. HPV prevalence was obtained using two PCR assays that differ in sensitivity and type spectrum, namely GP5+/GP6+ and E7-MPG. 92% students in Bhutan and 43% in Rwanda reported to have been vaccinated (median vaccination age = 16, 5th-95th: 14-18). HPV positivity in urine was significantly associated with sexual activity measures. In Rwanda, HPV6/11/16/18 prevalence was lower in vaccinated than in unvaccinated students (prevalence ratio, PR = 0.12, 95% confidence interval, CI: 0.03-0.51 by GP5+/GP6+, and 0.45, CI: 0.23-0.90 by E7-MPG). For E7-MPG, cross-protection against 10 high-risk types phylogenetically related to HPV16 or 18 was of borderline significance (PR = 0.68; 95% CI: 0.45-1.01). In Bhutan, HPV6/11/16/18 prevalence by GP5+/GP6+ was lower in vaccinated than in unvaccinated students but CIs were broad. In conclusion, our study supports the feasibility of urine surveys to monitor HPV vaccination and quantifies the effectiveness of the quadrivalent vaccine in women vaccinated after pre-adolescence. Future similar surveys should detect increases in vaccine effectiveness if vaccination of 12 year-olds continues. © 2016 UICC.

  14. Determination of oxycodone and its major metabolites noroxycodone and oxymorphone by ultra-high-performance liquid chromatography tandem mass spectrometry in plasma and urine: application to real cases.

    PubMed

    Pantano, Flaminia; Brauneis, Stefano; Forneris, Alexandre; Pacifici, Roberta; Marinelli, Enrico; Kyriakou, Chrystalla; Pichini, Simona; Busardò, Francesco Paolo

    2017-08-28

    Oxycodone is a narcotic drug widely used to alleviate moderate and severe acute and chronic pain. Variability in analgesic efficacy could be explained by inter-subject variations in plasma concentrations of parent drug and its active metabolite, oxymorphone. To evaluate patient compliance and to set up therapeutic drug monitoring (TDM), an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay was developed and validated for the parent drug and its major metabolites noroxycodone and oxymorphone. Extraction of analytes from plasma and urine samples was obtained by simple liquid-liquid extraction. The chromatographic separation was achieved with a reversed phase column using a linear gradient elution with two solvents: acetic acid 1% in water and methanol. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI). Separation of analytes was obtained in less than 5 min. Linear calibration curves for all the analytes under investigation in urine and plasma samples showed determination coefficients (r2) equal or higher than 0.990. Mean absolute analytical recoveries were always above 86%. Intra- and inter-assay precision (measured as coefficient of variation, CV%) and accuracy (measured as % error) values were always better than 13%. Limit of detection at 0.06 and 0.15 ng/mL and limit of quantification at 0.2 and 0.5 ng/mL for plasma and urine samples, respectively, were adequate for the purpose of the present study. Rapid extraction, identification and quantification of oxycodone and its metabolites both in urine and plasma by UHPLC-MS/MS assay was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in patients under oxycodone treatment.

  15. Cannabis Use Surveillance by Sweat Analysis.

    PubMed

    Gambelunghe, Cristiana; Fucci, Nadia; Aroni, Kyriaki; Bacci, Mauro; Marcelli, Antonio; Rossi, Riccardo

    2016-10-01

    Sweat testing, an alternative matrix for establishing drug abuse, offers additional benefits to the more common biological samples. The authors developed a procedure using gas chromatography-mass spectrometry to test for Δ9-tetrahydrocannabinol, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid, cannabinol (CBN), and cannabidiol (CBD) in a sweat patch. The results were compared with urine and hair sample results. Urine, hair, and sweat samples were simultaneously collected from 12 patients who were involved, respectively, in forensic case and monitoring abuse. Selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, intraday and interday imprecision, and inaccuracy of the quantification procedure were validated. LODs in hair were 0.05 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.005 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOD for sweat was 0.30 ng/patch for all substances. The LOQ in hair was 0.1 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.01 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOQ was 0.4 ng/patch in sweat for each analyte. Cannabinoid in urine was determined by means of immunochemical screening (cutoff 11-nor-Δ-tetrahydrocannabinol-9-carboxylic acid 50 ng/mL). All subjects tested positive for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid and Δ9-tetrahydrocannabinol in urine and hair. In sweat samples, Δ9-tetrahydrocannabinol was found in all patches (0.4-2.0 ng/patch); 6 cases were positive for CBN (0.4-0.5 ng/patch) and 3 for CBD (0.4-0.6 ng/patch); 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid was never detected in patches. Present sweat analysis results integrated the information from hair and urine and showed that sweat analysis is a suitable, noninvasive method for monitoring compliance with rehabilitation therapy and for detecting recent cumulative use of cannabinoids.

  16. Utility of ELISA screening for the monitoring of abstinence from illegal and legal drugs in hair and urine.

    PubMed

    Agius, Ronald; Nadulski, Thomas

    2014-06-01

    Amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in authentic hair samples with drug concentrations around the medical and psychological assessment (MPA) guidelines cut-offs were screened by LUCIO-direct ELISA kits. Following confirmation of all positive and a significant number of negatively screened samples with gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods accredited for forensic purposes. Receiver operating characteristics (ROC) were plotted and the area under the curve (AUC) and overall misclassification rate (OMR) were calculated and compared to those obtained for the same drug classes in urine. While fulfilling the validation criteria of the German forensic guidelines, for almost all screening tests in hair and urine the AUC were greater than 0.8, indicating good to excellent performance. Moreover the AUC calculated for the detection of drugs in hair did not differ significantly to the AUC calculated for the detection of the same drug classes in urine, thus showing a comparable screening performance to the well accepted, previously published application of the same ELISAs for the detection of drugs at unconventionally low cut-offs in urine. For the first time, the validation of the immunoassay tests for the complete 6-drug panel MPA profile in hair and urine using a large population of authentic hair and urine samples with drug concentrations around MPA cut-offs, lower than conventional clinical or workplace drug testing guidelines cut-offs as well as those suggested by the Society of hair testing (SoHT) is presented. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Natural calcium isotonic composition of urine as a marker of bone mineral balance

    USGS Publications Warehouse

    Skulan, J.; Bullen, T.; Anbar, A.D.; Puzas, J.E.; Shackelford, L.; LeBlanc, A.; Smith, S.M.

    2007-01-01

    Background: We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Methods: Calcium isotopic compositions are expressed as ??44Ca, or the difference in parts per thousand between the 44Ca/40Ca of a sample and the 44Ca/ 40Ca of a standard reference material. ??44Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Results: Urine ??44Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, Mest). Results were consistent with the model and with biochemical and bone mineral density data. Conclusion: Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool. ?? 2007 American Association for Clinical Chemistry.

  18. Simultaneous and confirmative detection of multi-residues of β₂-agonists and β-blockers in urine using LC-MS/MS/MS coupled with β-receptor molecular imprinted polymer SPE clean-up.

    PubMed

    Fan, S; Zou, J H; Miao, H; Zhao, Y F; Chen, H J; Zhao, R; Wu, Y N

    2013-01-01

    A liquid chromatography-linear ion-trap spectrometry (LC-MS³) method using β-receptor molecular-imprinted polymer (MIP) solid-phase extraction (SPE) as clean-up was developed to determine simultaneously and confirmatively residues of 25 β₂-agonists and 21 β-blockers in urine samples. Urine samples were subjected to enzymatic hydrolysis by β-glucoronidase/arylsulphatase, and then extracted with perchloric acid. Sample clean-up was performed using β-receptor MIP SPE. A Supelco Ascentis® express Rp-Amide column was used to separate the analytes, and MS³ detection used an electrospray ionisation source in positive-ion mode. Recovery studies were carried out using blank urine samples fortified with the 46 analytes at the levels of 0.5, 1.0 and 2.0 μg l⁻¹. Recoveries were obtained ranging from 60.1% to 109.9% with relative standard deviations (RSDs, n = 7) from 0.5% to 19.4%. The limits of detection (LODs) and limits of quantitation (LOQs) of the 46 analytes in urine were 0.02-0.18 and 0.05-0.60 μg l⁻¹, respectively. As a result of the selective clean-up by MIP SPE and MS³ detection of the target drugs, the sensitivity and accuracy of the present method was high enough for monitoring β₂-agonist and β-blocker residues in urine samples. Satisfactory results were obtained in the process of the determination of positive urine samples.

  19. Mass spectrometric characterisation of a condensation product between porphobilinogen and indolyl-3-acryloylglycine in urine of patients with acute intermittent porphyria.

    PubMed

    Marcos, Josep; Ibañez, Maria; Ventura, Rosa; Segura, Jordi; To-Figueras, Jordi; Pozo, Oscar J

    2015-07-01

    We document the presence of a previously unknown species in the urine of patients with acute intermittent porphyria (AIP). The compound was fully characterised by liquid chromatography tandem mass spectrometry. Interpretation of both full spectrum acquisition and product ion spectra acquired in positive and negative ionisation modes by quadrupole time of flight MS allowed for the identification of a condensation product arising from porphobilinogen (PBG, increased in the urine of AIP patients) and indolyl-3-acryloylglycine (IAG, derived from indolylacrylic acid and present in human urine). The structure was unequivocally confirmed through comparison between the selected reaction monitoring chromatograms obtained from the urinary species and the condensation product qualitatively synthesised in the laboratory. Owing to the large amounts of both PBG and IAG in urine of AIP patients, the possible ex vivo formation of PBG-IAG in urine samples was evaluated. The product was spontaneously formed at room temperature, at 4 °C and even during storage at -20 °C when spiking a control sample with PBG. A positive correlation was found between PBG and PBG-IAG in samples collected from AIP patients. However, no correlation was found between PBG-IAG and IAG. Purified PBG-IAG did not form the characteristic chromogen after application of p-dimethylaminobenzaldehyde in HCl, thus suggesting that the current techniques used to measure PBG in urine of AIP patients based on Ehlrich's reaction do not detect this newly characterised PBG-IAG fraction. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Prednisolone and prednisone neo-formation in bovine urine after sampling.

    PubMed

    Arioli, F; Casati, A; Fidani, M; Silvestri, M; Pompa, G

    2012-06-01

    The rise in the frequency of detecting prednisolone in bovine urine from northern Italy has come into focus of attention in recent years. The possibility that neo-formation of prednisolone or that prednisone may occur in urine after collection of samples was therefore investigated. Cow urine collected for official routine controls in Lombardy containing more than 80 ng/ml cortisol, and prednisolone and prednisone below the decision limit (CCα) of the method (0.4 and 0.5 ng/ml, respectively) was used. The C1-2 dehydrogenation of naturally present cortisol and cortisone was checked by incubating urine, both contaminated and uncontaminated with faeces, at 37°C and by collecting samples at 0, 1, 2, 4, 6 and 24 h. The influence of Helix pomatia juice was also investigated in order to determine whether deconjugation could influence the reliability of the results. All samples were analysed by HPLC-MS3 for the presence of cortisol, cortisone, prednisolone and prednisone in negative electrospray ionisation mode, utilising the consecutive reaction monitoring of product ions derived from the formate molecular adduct ([M+HCOO]-). The observed neo-formation of prednisolone shows that inappropriate temperatures in sample storage and processing can result in an incorrect accusation of non-compliance. The faecal contamination of urine, performed with the aim to mimic a collection conducted without the necessary care, moreover, evoked a high increase in prednisolone concentration in two out of seven animals. Moreover, H. pomatia juice had no significant effect on the prednisolone concentration, indicating that this corticosteroid is present in its free form in cow urine.

  1. Simultaneous detection of 15 antibiotic growth promoters in bovine muscle, blood and urine by UPLC-MS/MS.

    PubMed

    Wang, Zhi; Shi, Zongwei; Xi, Cunxian; Wang, Guomin; Cao, Shurui; Zhang, Lei; Tang, Bobin; Mu, Zhaode

    2017-12-01

    An analytical method was established for the rapid detection of antibiotic growth promoters (AGPs) in bovine muscle, and bovine blood and bovine urine, using ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). After the addition of an aqueous solution of EDTA-Na 2 , the pH of bovine urine samples was directly adjusted to 5.2 by acetic acid-ammonium acetate and purified by HLB solid-phase extraction cartridge; bovine muscle and bovine blood samples processing were extracted with acetonitrile (ACN) and ACNwater (90:10; v/v) without any purification step. The samples were then centrifuged, concentrated and analysed by UPLC-MS/MS on an ACQUITY UPLC® BEH C18 column using gradient elution. The developed method was validated and mean recovery percentages at three spiked levels were 74-119%, 76-115% and 76-119%, respectively, in bovine muscle, bovine blood, and bovine urine. The relative standard deviation (RSD) ranged from 1.0% to 14.7% in spiked bovine muscle, bovine blood and bovine urine. The limits of detection (LOD) of all analytes were in the ranges 0.11-3.82 µg kg -1 , 0.10-2.49 µg kg -1 and 0.06-4.53 µg kg -1 in bovine muscle, bovine blood, and bovine urine, respectively. The method was sensitive, accurate and was applied to monitor real samples. To the best of our knowledge, this is first method available for simultaneous determination of several classes of APGs in bovine muscle, and bovine blood and bovine urine.

  2. Assessment of sodium status in large ruminants by measuring the sodium-to-potassium ratio in muzzle secretions.

    PubMed

    Singh, S P; Rani, D

    1999-09-01

    To develop a simple diagnostic test to assess sodium status in large ruminants on the basis of the sodium-to-potassium ratio (Na:K) and to determine its relevance. 7 buffalo heifers and 21 lactating, pregnant, and nonpregnant dairy cows and heifers. Buffalo heifers were subjected in 2 experiments to variable dietary sodium intake or sodium depletion and changes in sodium and potassium concentrations; Na:K was simultaneously monitored in various body fluids to study its value for indicating sodium status. Validity of the muzzle secretion test was assessed. Muzzle secretion and urinary Na:K and sodium concentration, but not serum electrolyte concentrations, reflected the sodium status of buffalo heifers in response to the widely variable intake of sodium (0.03 to 0.16% of dry matter [DM]). Progressive sodium depletion during an 11-day period, using saliva deprivation caused reciprocal changes in sodium and potassium concentrations in saliva and muzzle secretion, but not in urine. Decreasing urine sodium concentration was associated with decreasing urine potassium concentration. Saliva, urine, and muzzle secretion Na:K closely reflected the degree of sodium deficit. Buffaloes or dairy cows maintained on optimal sodium intake had muzzle secretion and urine Na:K > 0.30. Muzzle secretion or urine Na:K < 0.20 or < 0.10, respectively, was indicative of sodium deficiency. Analysis of muzzle secretion Na:K, and to a large extent urine Na:K, may be used as a convenient diagnostic tool to assess sodium status in large ruminants. It has accuracy similar to that of saliva Na:K.

  3. Preparation of magnetic ODS-PAN thin-films for microextraction of quetiapine and clozapine in plasma and urine samples followed by HPLC-UV detection.

    PubMed

    Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan

    2016-06-05

    In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Natural calcium isotopic composition of urine as a marker of bone mineral balance.

    PubMed

    Skulan, Joseph; Bullen, Thomas; Anbar, Ariel D; Puzas, J Edward; Shackelford, Linda; LeBlanc, Adrian; Smith, Scott M

    2007-06-01

    We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Calcium isotopic compositions are expressed as delta(44)Ca, or the difference in parts per thousand between the (44)Ca/(40)Ca of a sample and the (44)Ca/(40)Ca of a standard reference material. delta(44)Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Urine delta(44)Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, t-test). Results were consistent with the model and with biochemical and bone mineral density data. Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool.

  5. Time to Consider Use of the Sodium-to-Potassium Ratio for Practical Sodium Reduction and Potassium Increase

    PubMed Central

    Miura, Katsuyuki; Ueshima, Hirotsugu

    2017-01-01

    Pathogenetic studies have demonstrated that the interdependency of sodium and potassium affects blood pressure. Emerging evidences on the sodium-to-potassium ratio show benefits for a reduction in sodium and an increase in potassium compared to sodium and potassium separately. As presently there is no known review, this article examined the practical use of the sodium-to-potassium ratio in daily practice. Epidemiological studies suggest that the urinary sodium-to-potassium ratio may be a superior metric as compared to separate sodium and potassium values for determining the relation to blood pressure and cardiovascular disease risks. Higher correlations and better agreements are seen for the casual urine sodium-to-potassium ratio than for casual urine sodium or potassium alone when compared with the 24-h urine values. Repeated measurements of the casual urine provide reliable estimates of the 7-day 24-h urine value with less bias for the sodium-to-potassium ratio as compared to the common formulas used for estimating the single 24-h urine from the casual urine for sodium and potassium separately. Self-monitoring devices for the urinary sodium-to-potassium ratio measurement makes it possible to provide prompt onsite feedback. Although these devices have been evaluated with a view to support an individual approach for sodium reduction and potassium increase, there has yet to be an accepted recommended guideline for the sodium-to-potassium ratio. This review concludes with a look at the practical use of the sodium-to-potassium ratio for assistance in practical sodium reduction and potassium increase. PMID:28678188

  6. A one-year monitoring of nicotine use in sport: frontier between potential performance enhancement and addiction issues.

    PubMed

    Marclay, François; Grata, Elia; Perrenoud, Laurent; Saugy, Martial

    2011-12-10

    Tobacco consumption is a global epidemic responsible for a vast burden of disease. With pharmacological properties sought-after by consumers and responsible for addiction issues, nicotine is the main reason of this phenomenon. Accordingly, smokeless tobacco products are of growing popularity in sport owing to potential performance enhancing properties and absence of adverse effects on the respiratory system. Nevertheless, nicotine does not appear on the 2011 World Anti-Doping Agency (WADA) Prohibited List or Monitoring Program by lack of a comprehensive large-scale prevalence survey. Thus, this work describes a one-year monitoring study on urine specimens from professional athletes of different disciplines covering 2010 and 2011. A method for the detection and quantification of nicotine, its major metabolites (cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide) and minor tobacco alkaloids (anabasine, anatabine and nornicotine) was developed, relying on ultra-high pressure liquid chromatography coupled to triple quadrupole mass spectrometry (UHPLC-TQ-MS/MS). A simple and fast dilute-and-shoot sample treatment was performed, followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in positive electrospray ionization (ESI) mode with multiple reaction monitoring (MRM) data acquisition. After method validation, assessing the prevalence of nicotine consumption in sport involved analysis of 2185 urine samples, accounting for 43 different sports. Concentrations distribution of major nicotine metabolites, minor nicotine metabolites and tobacco alkaloids ranged from 10 (LLOQ) to 32,223, 6670 and 538 ng/mL, respectively. Compounds of interest were detected in trace levels in 23.0% of urine specimens, with concentration levels corresponding to an exposure within the last three days for 18.3% of samples. Likewise, hypothesizing conservative concentration limits for active nicotine consumption prior and/or during sport practice (50 ng/mL for nicotine, cotinine and trans-3-hydroxycotinine and 25 ng/mL for nicotine-N'-oxide, cotinine-N-oxide, anabasine, anatabine and nornicotine) revealed a prevalence of 15.3% amongst athletes. While this number may appear lower than the worldwide smoking prevalence of around 25%, focusing the study on selected sports highlighted more alarming findings. Indeed, active nicotine consumption in ice hockey, skiing, biathlon, bobsleigh, skating, football, basketball, volleyball, rugby, American football, wrestling and gymnastics was found to range between 19.0 and 55.6%. Therefore, considering the adverse effects of smoking on the respiratory tract and numerous health threats detrimental to sport practice at top level, likelihood of smokeless tobacco consumption for performance enhancement is greatly supported. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Urinary Phenylacetylglutamine as Dosing Biomarker for Patients with Urea Cycle Disorders

    PubMed Central

    Mokhtarani, M; Diaz, GA; Rhead, W; Lichter-Konecki, U; Bartley, J; Feigenbaum, A; Longo, N; Berquist, W; Berry, SA; Gallagher, R; Bartholomew, D; Harding, CO; Korson, MS; McCandless, SE; Smith, W; Vockley, J; Bart, S; Kronn, D; Zori, R; Cederbaum, S; Dorrani, N; Merritt, JL; Sreenath-Nagamani, Sandesh; Summar, M; LeMons, C; Dickinson, K; Coakley, DF; Moors, TL; Lee, B; Scharschmidt, BF

    2013-01-01

    We have analyzed pharmacokinetic data for glycerol phenylbutyrate (also GT4P or HPN-100) and sodium phenylbutyrate with respect to possible dosing biomarkers in patients with urea cycle disorders (UCD). Study Design These analyses are based on over 3000 urine and plasma data points from 54 adult and 11 pediatric UCD patients (ages 6–17) who participated in three clinical studies comparing ammonia control and pharmacokinetics during steady state treatment with glycerol phenylbutyrate or sodium phenylbutyrate. All patients received phenylbutyric acid equivalent doses of glycerol phenylbutyrate or sodium phenylbutyrate in a cross over fashion and underwent 24-hour blood samples and urine sampling for phenylbutyric acid, phenylacetic acid and phenylacetylglutamine. Results Patients received phenylbutyric acid equivalent doses of glycerol phenylbutyrate ranging from 1.5–31.8 g/day and of sodium phenylbutyrate ranging from 1.3–31.7 g/day. Plasma metabolite levels varied widely, with average fluctuation indices ranging from 1979% –5690% for phenylbutyric acid, 843% to 3931% for phenylacetic acid, and 881% -to 1434% for phenylacetylglutamine. Mean percent recovery of phenylbutyric acid as urinary phenylacetylglutamine was 66.4 and 69.0 for pediatric patients and 68.7 and 71.4 for adult patients on glycerol phenylbutyrate and sodium phenylbutyrate, respectively. The correlation with dose was strongest for urinary phenylacetylglutamine excretion, either as morning spot urine (r=0.730, p<0.001) or as total 24-hour excretion (r=0.791 p<0.001), followed by plasma phenylacetylglutamine AUC24-hour, plasma phenylacetic acid AUC24-hour and phenylbutyric acid AUC24-hour. Plasma phenylacetic acid levels in adult and pediatric patients did not show a consistent relationship with either urinary phenylacetylglutamine or ammonia control. Conclusion The findings are collectively consistent with substantial yet variable pre-systemic (1st pass) conversion of phenylbutyric acid to phenylacetic acid and/or phenylacetylglutamine. The variability of blood metabolite levels during the day, their weaker correlation with dose, the need for multiple blood samples to capture trough and peak, and the inconsistency between phenylacetic acid and urinary phenylacetylglutamine as a marker of waste nitrogen scavenging limit the utility of plasma levels for therapeutic monitoring. By contrast, 24-hour urinary phenylacetylglutamine and morning spot urine phenylacetylglutamine correlate strongly with dose and appear to be clinically useful non-invasive biomarkers for compliance and therapeutic monitoring. PMID:22958974

  8. Urinary phenylacetylglutamine as dosing biomarker for patients with urea cycle disorders.

    PubMed

    Mokhtarani, M; Diaz, G A; Rhead, W; Lichter-Konecki, U; Bartley, J; Feigenbaum, A; Longo, N; Berquist, W; Berry, S A; Gallagher, R; Bartholomew, D; Harding, C O; Korson, M S; McCandless, S E; Smith, W; Vockley, J; Bart, S; Kronn, D; Zori, R; Cederbaum, S; Dorrani, N; Merritt, J L; Sreenath-Nagamani, Sandesh; Summar, M; Lemons, C; Dickinson, K; Coakley, D F; Moors, T L; Lee, B; Scharschmidt, B F

    2012-11-01

    We have analyzed pharmacokinetic data for glycerol phenylbutyrate (also GT4P or HPN-100) and sodium phenylbutyrate with respect to possible dosing biomarkers in patients with urea cycle disorders (UCD). These analyses are based on over 3000 urine and plasma data points from 54 adult and 11 pediatric UCD patients (ages 6-17) who participated in three clinical studies comparing ammonia control and pharmacokinetics during steady state treatment with glycerol phenylbutyrate or sodium phenylbutyrate. All patients received phenylbutyric acid equivalent doses of glycerol phenylbutyrate or sodium phenylbutyrate in a cross over fashion and underwent 24-hour blood samples and urine sampling for phenylbutyric acid, phenylacetic acid and phenylacetylglutamine. Patients received phenylbutyric acid equivalent doses of glycerol phenylbutyrate ranging from 1.5 to 31.8 g/day and of sodium phenylbutyrate ranging from 1.3 to 31.7 g/day. Plasma metabolite levels varied widely, with average fluctuation indices ranging from 1979% to 5690% for phenylbutyric acid, 843% to 3931% for phenylacetic acid, and 881% to 1434% for phenylacetylglutamine. Mean percent recovery of phenylbutyric acid as urinary phenylacetylglutamine was 66.4 and 69.0 for pediatric patients and 68.7 and 71.4 for adult patients on glycerol phenylbutyrate and sodium phenylbutyrate, respectively. The correlation with dose was strongest for urinary phenylacetylglutamine excretion, either as morning spot urine (r = 0.730, p < 0.001) or as total 24-hour excretion (r = 0.791 p<0.001), followed by plasma phenylacetylglutamine AUC(24-hour), plasma phenylacetic acid AUC(24-hour) and phenylbutyric acid AUC(24-hour). Plasma phenylacetic acid levels in adult and pediatric patients did not show a consistent relationship with either urinary phenylacetylglutamine or ammonia control. The findings are collectively consistent with substantial yet variable pre-systemic (1st pass) conversion of phenylbutyric acid to phenylacetic acid and/or phenylacetylglutamine. The variability of blood metabolite levels during the day, their weaker correlation with dose, the need for multiple blood samples to capture trough and peak, and the inconsistency between phenylacetic acid and urinary phenylacetylglutamine as a marker of waste nitrogen scavenging limit the utility of plasma levels for therapeutic monitoring. By contrast, 24-hour urinary phenylacetylglutamine and morning spot urine phenylacetylglutamine correlate strongly with dose and appear to be clinically useful non-invasive biomarkers for compliance and therapeutic monitoring. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. A urine-fuelled soil-based bioregenerative life support system for long-term and long-distance manned space missions

    NASA Astrophysics Data System (ADS)

    Maggi, Federico; Tang, Fiona H. M.; Pallud, Céline; Gu, Chuanhui

    2018-05-01

    A soil-based cropping unit fuelled with human urine for long-term manned space missions was investigated with the aim to analyze whether a closed-loop nutrient cycle from human liquid wastes was achievable. Its ecohydrology and biogeochemistry were analysed in microgravity with the use of an advanced computational tool. Urine from the crew was used to supply primary (N, P, and K) and secondary (S, Ca and Mg) nutrients to wheat and soybean plants in the controlled cropping unit. Breakdown of urine compounds into primary and secondary nutrients as well as byproduct gases, adsorbed, and uptake fractions were tracked over a period of 20 years. Results suggested that human urine could satisfy the demand of at least 3 to 4 out of 6 nutrients with an offset in pH and salinity tolerable by plants. It was therefore inferred that a urine-fuelled life support system can introduce a number of advantages including: (1) recycling of liquids wastes and production of food; (2) forgiveness of neglect as compared to engineered electro-mechanical systems that may fail under unexpected or unplanned conditions; and (3) reduction of supply and waste loads during space missions.

  10. Detection of vesicoureteral reflux using microwave radiometry-system characterization with tissue phantoms.

    PubMed

    Arunachalam, Kavitha; Maccarini, Paolo; De Luca, Valeria; Tognolatti, Piero; Bardati, Fernando; Snow, Brent; Stauffer, Paul

    2011-06-01

    Microwave (MW) radiometry is proposed for passive monitoring of kidney temperature to detect vesicoureteral reflux (VUR) of urine that is externally heated by a MW hyperthermia device and thereafter reflows from the bladder to kidneys during reflux. Here, we characterize in tissue-mimicking phantoms the performance of a 1.375 GHz radiometry system connected to an electromagnetically (EM) shielded microstrip log spiral antenna optimized for VUR detection. Phantom EM properties are characterized using a coaxial dielectric probe and network analyzer (NA). Power reflection and receive patterns of the antenna are measured in layered tissue phantom. Receiver spectral measurements are used to assess EM shielding provided by a metal cup surrounding the antenna. Radiometer and fiberoptic temperature data are recorded for varying volumes (10-30 mL) and temperaturesg (40-46°C) of the urine phantom at 35 mm depth surrounded by 36.5°C muscle phantom. Directional receive pattern with about 5% power spectral density at 35 mm target depth and better than -10 dB return loss from tissue load are measured for the antenna. Antenna measurements demonstrate no deterioration in power reception and effective EM shielding in the presence of the metal cup. Radiometry power measurements are in excellent agreement with the temperature of the kidney phantom. Laboratory testing of the radiometry system in temperature-controlled phantoms supports the feasibility of passive kidney thermometry for VUR detection.

  11. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    PubMed

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Direct determination of N-methyl-2-pyrrolidone metabolites in urine by HPLC-electrospray ionization-MS/MS using deuterium-labeled compounds as internal standard.

    PubMed

    Suzuki, Yoshihiro; Endo, Yoko; Ogawa, Masanori; Yamamoto, Shinobu; Takeuchi, Akito; Nakagawa, Tomoo; Onda, Nobuhiko

    2009-11-01

    N-methyl-2-pyrrolidone (NMP) has been used in many industries and biological monitoring of NMP exposure is preferred to atmospheric monitoring in occupational health. We developed an analytical method that did not include solid phase extraction (SPE) but utilized deuterium-labeled compounds as internal standard for high-performance liquid chromatography-electrospray ionization-mass spectrometry using a C30 column. Urinary concentrations of NMP and its known metabolites 5-hydoxy-N-methyl-2-pyrrolidone (5-HNMP), N-methyl-succinimide (MSI), and 2-hydroxy-N-methylsuccinimide (2-HMSI) were determined in a single run. The method provided baseline separation of these compounds. Their limits of detection in 10-fold diluted urine were 0.0001, 0.006, 0.008, and 0.03 mg/L, respectively. Linear calibration covered a biological exposure index (BEI) for urinary concentration. The within-run and total precisions (CV, %) were 5.6% and 9.2% for NMP, 3.4% and 4.2% for 5-HNMP, 3.7% and 6.0% for MSI, and 6.5% and 6.9% for 2-HMSI. The method was evaluated using international external quality assessment samples, and urine samples from workers exposed to NMP in an occupational area.

  13. Monitoring of heavy metal levels in the major rivers and in residents' blood in Zhenjiang City, China, and assessment of heavy metal elimination via urine and sweat in humans.

    PubMed

    Sheng, Jianguo; Qiu, Wenhui; Xu, Bentuo; Xu, Hui; Tang, Chong

    2016-06-01

    The coastal areas of China face great challenges, owing to heavy metal contamination caused by rapid industrialization and urbanization. To our knowledge, this study is the first report of the levels of heavy metals in the major rivers of Zhenjiang, one of the most important cities of the Yangtze River Delta in China. In addition, we measured heavy metal levels in the blood of 76 residents of Zhenjiang. The results suggest that the presence of heavy metals in the blood may threaten human health and the distribution appeared to correspond to most highly populated areas and/or areas with high traffic. We also found that the concentration of heavy metals in human blood showed an accumulation effect with increase in age. Moreover, the levels of most heavy metals were lower in participants who regularly exercised than in those who did not. We studied heavy metal levels in the urine and sweat of another 17 volunteers to monitor the elimination of bioaccumulated heavy metal. Heavy metals were found in the urine and sweat of all the 17 participants and were more concentrated in sweat. Induced micturition and sweating appear to be potential methods for the elimination of heavy metals from the human body.

  14. Life Support and Environmental Monitoring International System Maturation Team Considerations.

    NASA Technical Reports Server (NTRS)

    Anderson, Molly; Gatens, Robyn; Ikeda, Toshitami; Ito, Tsuyoshi; Hovland, Scott; Witt, Johannes

    2016-01-01

    Human exploration of the solar system is an ambitious goal. Future human missions to Mars or other planets will require the cooperation of many nations to be feasible. Exploration goals and concepts have been gathered by the International Space Exploration Coordination Group (ISECG) at a very high level, representing the overall goals and strategies of each participating space agency. The Global Exploration Roadmap published by ISECG states that international partnerships are part of what drives the the mission scenarios. It states "Collaborations will be established at all levels (missions, capabilities, technologies), with various levels of interdependency among the partners." To make missions with interdependency successful, technologists and system experts need to share information early, before agencies have made concrete plans and binding agreements. This paper provides an overview of possible ways of integrating NASA, ESA, and JAXA work into a conceptual roadmap of life support and environmental monitoring capabilities for future exploration missions. Agencies may have immediate plans as well as long term goals or new ideas that are not part of official policy. But relationships between plans and capabilities may influence the strategies for the best ways to achieve partner goals. Without commitments and an organized program like the International Space Station, requirements for future missions are unclear. Experience from ISS has shown that standards and an early understanding of requirements are an important part of international partnerships. Attempting to integrate systems that were not designed together can create many problems. Several areas have been identified that could be important to discuss and understand early: units of measure, cabin CO2 levels, and the definition and description of fluids like high purity oxygen, potable water and residual biocide, and crew urine and urine pretreat. Each of the partners is exploring different kinds of technologies. Different specific parameters may important to define or explore possible ranges depending on the system concepts. Early coordination between technology developers can create new possibilities for collaboration, and provide input to determine what combined options may provide the best overall system architecture.

  15. Life Support and Environmental Monitoring International System Maturation Team Considerations

    NASA Technical Reports Server (NTRS)

    Anderson, Molly; Gatens, Robyn; Ikeda, Toshitami; Ito, Tsuyoshi; Hovland, Scott; Witt, Johannes

    2016-01-01

    Human exploration of the solar system is an ambitious goal. Future human missions to Mars or other planets will require the cooperation of many nations to be feasible. Exploration goals and concepts have been gathered by the International Space Exploration Coordination Group (ISECG) at a very high level, representing the overall goals and strategies of each participating space agency. The Global Exploration Roadmap published by ISECG states that international partnerships are part of what drives the mission scenarios. It states "Collaborations will be established at all levels (missions, capabilities, technologies), with various levels of interdependency among the partners." To make missions with interdependency successful, technologists and system experts need to share information early, before agencies have made concrete plans and binding agreements. This paper provides an overview of possible ways of integrating NASA, ESA, and JAXA work into a conceptual roadmap of life support and environmental monitoring capabilities for future exploration missions. Agencies may have immediate plans as well as long term goals or new ideas that are not part of official policy. But relationships between plans and capabilities may influence the strategies for the best ways to achieve partner goals. Without commitments and an organized program like the International Space Station, requirements for future missions are unclear. Experience from ISS has shown that standards and an early understanding of requirements are an important part of international partnerships. Attempting to integrate systems that were not designed together can create many problems. Several areas have been identified that could be important to discuss and understand early: units of measure, cabin CO2 levels, and the definition and description of fluids like high purity oxygen, potable water and residual biocide, and crew urine and urine pretreat. Each of the partners is exploring different kinds of technologies. Different specific parameters may important to define or explore possible ranges depending on the system concepts. Early coordination between technology developers can create new possibilities for collaboration, and provide input to determine what combined options may provide the best overall system architecture.

  16. Development of Low-Toxicity Urine Stabilization for Spacecraft Water Recovery Systems

    NASA Technical Reports Server (NTRS)

    Adam, Niklas; Mitchell, Julie L.; Pickering, Karen D.

    2012-01-01

    Wastewater stabilization is an essential component of the spacecraft water cycle. The purpose of stabilizing wastewater is two-fold. First, stabilization prevents the breakdown of urea into ammonia, a toxic gas at high concentrations. Second, it prevents the growth of microorganisms, thereby mitigating hardware and water quality issues due to due biofilm and planktonic growth. Current stabilization techniques involve oxidizers and strong acids (pH=2) such as chromic and sulfuric acid, which are highly toxic and pose a risk to crew health. The purpose of this effort is to explore less toxic stabilization techniques, such as food-grade and commercial care preservatives. Additionally, certain preservatives were tested in the presence of a low-toxicity organic acid. Triplicate 300-mL volumes of urine were dosed with a predetermined quantity of stabilizer and stored for two weeks. During that time, pH, total organic carbon (TOC), ammonia, and turbidity were monitored. Those preservatives that showed the lowest visible microbial growth and stable pH were further tested in a six-month stability study. The results of the six-month study are also included in this paper.

  17. Soil nitrous oxide emissions after deposition of dairy cow excreta in eastern Canada.

    PubMed

    Rochette, Philippe; Chantigny, Martin H; Ziadi, Noura; Angers, Denis A; Bélanger, Gilles; Charbonneau, Édith; Pellerin, Doris; Liang, Chang; Bertrand, Normand

    2014-05-01

    Urine and dung deposited by grazing dairy cows are a major source of nitrous oxide (NO), a potent greenhouse gas that contributes to stratospheric ozone depletion. In this study, we quantified the emissions of NO after deposition of dairy cow excreta onto two grassland sites with contrasting soil types in eastern Canada. Our objectives were to determine the impact of excreta type, urine-N rate, time of the year, and soil type on annual NO emissions. Emissions were monitored on sandy loam and clay soils after spring, summer, and fall urine (5 and 10 g N patch) and dung (1.75 kg fresh weight dung) applications to perennial grasses in two successive years. The mean NO emission factor (EF) for urine was 1.09% of applied N in the clay soil and 0.31% in the sandy loam soil, estimates much smaller than the default Intergovernmental Panel on Climate Change (IPCC) default value for total excreta N (2%). Despite variations in urine composition and in climatic conditions, these soil-specific EFs were similar for the two urine-N application rates. The time of the year when urine was applied had no impact on emissions from the sandy loam soil, but greater EFs were observed after summer (1.59%) than spring (1.14%) and fall (0.55%) applications in the clay soil. Dung deposition impact on NO emission was smaller than that of urine, with a mean EF of 0.15% in the sandy loam soil and 0.08% in the clay soil. Our results suggest (i) that the IPCC default EF overestimates NO emissions from grazing cattle excreta in eastern Canada by a factor of 4.3 and (ii) that a region-specific inventory methodology should account for soil type and should use specific EFs for urine and dung. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  18. Primary Care Providers’ Experiences with Urine Toxicology Tests to Manage Prescription Opioid Misuse and Substance Use Among Chronic Non-Cancer Pain Patients in Safety Net Healthcare Settings

    PubMed Central

    Ceasar, Rachel; Chang, Jamie; Zamora, Kara; Hurstak, Emily; Kushel, Margot; Miaskowski, Christine; Knight, Kelly

    2016-01-01

    Background Guideline recommendations to reduce prescription opioid misuse among patients with chronic non-cancer pain include the routine use of urine toxicology tests for high-risk patients. Yet little is known about how the implementation of urine toxicology tests among patients with co-occurring chronic non-cancer pain and substance use impacts primary care providers’ management of misuse. In this paper, we present clinicians’ perspectives on the benefits and challenges of implementing urine toxicology tests in the monitoring of opioid misuse and substance use in safety net healthcare settings. Methods We interviewed 23 primary care providers from six safety net healthcare settings whose patients had a diagnosis of co-occurring chronic non-cancer pain and substance use. We transcribed, coded, and analyzed interviews using grounded theory methodology. Results The benefits of implementing urine toxicology tests for primary care providers included less reliance on intuition to assess for misuse and the ability to identify unknown opioid misuse and/or substance use. The challenges of implementing urine toxicology tests included insufficient education and training about how to interpret and implement tests, and a lack of clarity on how and when to act on tests that indicated misuse and/or substance use. Conclusions These data suggest that primary care clinicians’ lack of education and training to interpret and implement urine toxicology tests may impact their management of patient opioid misuse and/or substance use. Clinicians may benefit from additional education and training about the clinical implementation and use of urine toxicology tests. Additional research is needed on how primary care providers implementation and use of urine toxicology tests impacts chronic non-cancer pain management in primary care and safety net healthcare settings among patients with co-occurring chronic non-cancer pain and substance use. PMID:26682471

  19. Development testing of a shuttle urine collection system

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Flight tests conducted in December 1973 demonstrated the ability of an unisexual urine collection subsystem to function in a zero-g environment. The urinal, which could be adjusted with three degrees of freedom, accommodated 16 female test subjects with a wide range of stature, as well as five male test subjects. The urinal was in intimate contact with the female and was contoured to form an effective air seal at the periphery. When positioned 2-4 inches forward, the urinal could be used for male collection and contact was not required.

  20. A Direct Aqueous Derivatization GSMS Method for Determining Benzoylecgonine Concentrations in Human Urine.

    PubMed

    Chericoni, Silvio; Stefanelli, Fabio; Da Valle, Ylenia; Giusiani, Mario

    2015-09-01

    A sensitive and reliable method for extraction and quantification of benzoylecgonine (BZE) and cocaine (COC) in urine is presented. Propyl-chloroformate was used as derivatizing agent, and it was directly added to the urine sample: the propyl derivative and COC were then recovered by liquid-liquid extraction procedure. Gas chromatography-mass spectrometry was used to detect the analytes in selected ion monitoring mode. The method proved to be precise for BZE and COC both in term of intraday and interday analysis, with a coefficient of variation (CV)<6%. Limits of detection (LOD) were 2.7 ng/mL for BZE and 1.4 ng/mL for COC. The calibration curve showed a linear relationship for BZE and COC (r2>0.999 and >0.997, respectively) within the range investigated. The method, applied to thirty authentic samples, showed to be very simple, fast, and reliable, so it can be easily applied in routine analysis for the quantification of BZE and COC in urine samples. © 2015 American Academy of Forensic Sciences.

  1. Distribution and Depletion of Ractopamine in Goat Plasma, Urine and Various Muscle Tissues.

    PubMed

    Zhao, Zhen; Gu, Xu; Su, Xiaoou; Li, Junguo; Li, Jun; Dong, Yingchao; Yang, Yujuan; Yao, Ting; Qin, Yuchang

    2017-01-01

    This study investigated the ractopamine (RAC) distribution and depletion process in goat plasma, urine and various muscle tissues which were associated with a potential risk for consumer health. The experiment was carried out in 21 goats (18 treated and 3 controls). Treated animals were administered orally a dose of 1 mg/kg body mass per day for 28 consecutive days and randomly sacrificed on Days 0.25, 1, 3, 7, 14 and 21 of the withdrawal period. RAC in goat samples was analyzed by using ultra-high performance liquid chromatography-quadrupole-orbitrap high-resolution mass spectrometry. RAC was below the limits of detection (LOD = 0.15 ng/mL) in plasma while which was higher than the LOD in urine on withdrawal day 21. The residues in goat longissimus dorsi muscle, biceps femoris muscle and triceps surae muscle were differed significantly. These findings demonstrated that urine can be used as the target matrix for monitoring RAC abuse in goat. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Rational use and interpretation of urine drug testing in chronic opioid therapy.

    PubMed

    Reisfield, Gary M; Salazar, Elaine; Bertholf, Roger L

    2007-01-01

    Urine drug testing (UDT) has become an essential feature of pain management, as physicians seek to verify adherence to prescribed opioid regimens and to detect the use of illicit or unauthorized licit drugs. Results of urine drug tests have important consequences in regard to therapeutic decisions and the trust between physician and patient. However, reliance on UDT to confirm adherence can be problematic if the results are not interpreted correctly, and evidence suggests that many physicians lack an adequate understanding of the complexities of UDT and the factors that can affect test results. These factors include metabolic conversion between drugs, genetic variations in drug metabolism, the sensitivity and specificity of the analytical method for a particular drug or metabolite, and the effects of intentional and unintentional interferants. In this review, we focus on the technical features and limitations of analytical methods used for detecting drugs or their metabolites in urine, the statistical constructs that are pertinent to ordering UDT and interpreting test results, and the application of these concepts to the clinical monitoring of patients maintained on chronic opioid therapy.

  3. Oxybuprocaine and five metabolites simultaneously determined in urine by gas chromatography and gas chromatography-mass spectrometry after extraction with Extrelut.

    PubMed

    Kasuya, F; Igarashi, K; Fukui, M

    1987-05-01

    We describe a gas-liquid chromatographic (GC) method for determination of oxybuprocaine, and a gas chromatographic-mass spectrometric (GC-MS) method for simultaneous determination of four of its nine metabolites in urine. We used an Extrelut column to simply and rapidly extract oxybuprocaine and its metabolites from urine. For the GC-MS analyses, we monitored the characteristic fragment ions at m/z 353, 395, 369, 411, and 235 for 3-butoxy-4-aminobenzoic acid (metabolite 2, M-2), 3-butoxy-4-acetylaminobenzoic acid (M-3), 3-hydroxy-4-aminobenzoic acid (M-4), 3-hydroxy-4-acetylaminobenzoic acid (M-5), and methaqualone (internal standard), respectively. We quantified the glucuronide of M-2 after enzymic treatment. The assay's selectivity and reproducibility (within-day and between-day CVs less than 8% for all metabolites) make it applicable to determine oxybuprocaine and its metabolites in human urine. Mean 9-h urinary excretion of oxybuprocaine and its five metabolites from four healthy volunteers was 89.2% after a 100-mg oral dose.

  4. Dermal absorption and urinary elimination of N-methyl-2-pyrrolidone.

    PubMed

    Bader, Michael; Keener, Stephen A; Wrbitzky, Renate

    2005-09-01

    The dermal absorption of the solvent N-methyl-2-pyrrolidone (NMP) and its elimination in urine was investigated in an experimental study. Seven volunteers were exposed to 1045 mg of liquid NMP under occlusive conditions for 2 h. Urine was collected before, during and up to 72 h after the exposure and analysed for NMP by GC/MS after liquid-liquid extraction. Additionally, the remaining NMP in the pads was determined to estimate the total dermal uptake. The concentration of NMP in urine increased rapidly after beginning of the exposure up to 1 h after the exposure was completed. A peak concentration of 1,836+/-863 microg/l was observed, the half-life in urine was 3.2 h. About 0.5% of the absorbed dose was excreted metabolically unchanged. An average dermal absorption of 5.5 mg cm(-2) h(-1) was calculated. The results of this study show that the percutaneous absorption of NMP may contribute significantly to the overall uptake of the solvent, e.g. in the workplace. Therefore, a biological monitoring of NMP exposed workers is essential for occupational-medical surveillance.

  5. Maple syrup urine disease: mechanisms and management.

    PubMed

    Blackburn, Patrick R; Gass, Jennifer M; Vairo, Filippo Pinto E; Farnham, Kristen M; Atwal, Herjot K; Macklin, Sarah; Klee, Eric W; Atwal, Paldeep S

    2017-01-01

    Maple syrup urine disease (MSUD) is an inborn error of metabolism caused by defects in the branched-chain α-ketoacid dehydrogenase complex, which results in elevations of the branched-chain amino acids (BCAAs) in plasma, α-ketoacids in urine, and production of the pathognomonic disease marker, alloisoleucine. The disorder varies in severity and the clinical spectrum is quite broad with five recognized clinical variants that have no known association with genotype. The classic presentation occurs in the neonatal period with developmental delay, failure to thrive, feeding difficulties, and maple syrup odor in the cerumen and urine, and can lead to irreversible neurological complications, including stereotypical movements, metabolic decompensation, and death if left untreated. Treatment consists of dietary restriction of BCAAs and close metabolic monitoring. Clinical outcomes are generally good in patients where treatment is initiated early. Newborn screening for MSUD is now commonplace in the United States and is included on the Recommended Uniform Screening Panel (RUSP). We review this disorder including its presentation, screening and clinical diagnosis, treatment, and other relevant aspects pertaining to the care of patients.

  6. Maple syrup urine disease: mechanisms and management

    PubMed Central

    Farnham, Kristen M; Atwal, Herjot K; Macklin, Sarah; Klee, Eric W; Atwal, Paldeep S

    2017-01-01

    Maple syrup urine disease (MSUD) is an inborn error of metabolism caused by defects in the branched-chain α-ketoacid dehydrogenase complex, which results in elevations of the branched-chain amino acids (BCAAs) in plasma, α-ketoacids in urine, and production of the pathognomonic disease marker, alloisoleucine. The disorder varies in severity and the clinical spectrum is quite broad with five recognized clinical variants that have no known association with genotype. The classic presentation occurs in the neonatal period with developmental delay, failure to thrive, feeding difficulties, and maple syrup odor in the cerumen and urine, and can lead to irreversible neurological complications, including stereotypical movements, metabolic decompensation, and death if left untreated. Treatment consists of dietary restriction of BCAAs and close metabolic monitoring. Clinical outcomes are generally good in patients where treatment is initiated early. Newborn screening for MSUD is now commonplace in the United States and is included on the Recommended Uniform Screening Panel (RUSP). We review this disorder including its presentation, screening and clinical diagnosis, treatment, and other relevant aspects pertaining to the care of patients. PMID:28919799

  7. Alkaline dehydration of anion-exchanged human urine: Volume reduction, nutrient recovery and process optimisation.

    PubMed

    Simha, Prithvi; Senecal, Jenna; Nordin, Annika; Lalander, Cecilia; Vinnerås, Björn

    2018-06-02

    In urine-separating sanitation systems, bacterial urease enzymes can hydrolyse urea to ammonia during the pipe transport and storage of urine. The present study investigated whether it was possible to reduce the urine volume without losing the nitrogen as ammonia. A method for stabilising the urine prior to dehydration was developed. Briefly, fresh human urine was stabilised by passage through an anion-exchanger, added to an alkaline media (wood ash or alkalised biochar), and dehydrated. Urine dehydration was investigated at three temperatures: 40, 45 and 50 °C. The influence of various factors affecting the dehydration process was modelled and the rate of urine dehydration was optimised. Results indicated that 75% (v/v) of the urine has to pass through the ion-exchanger for alkaline stabilisation of urine to occur. At all investigated temperatures, the dehydrator accomplished >90% volume reduction of ion-exchanged urine, > 70% N retention and 100% recovery of P and K. To realise high degree of nutrient valorisation, this study proposes combining source-separation of human urine with alkaline dehydration. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Jack Healy Remembers - Anecdotal Evidence for the Origin of the Approximate 24-hour Urine Sampling Protocol Used for Worker Bioassay Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.

    2008-10-01

    The origin of the approximate 24-hour urine sampling protocol used at Hanford for routine bioassay is attributed to an informal study done in the mid-1940s. While the actual data were never published and have been lost, anecdotal recollections by staff involved in the initial bioassay program design and administration suggest that the sampling protocol had a solid scientific basis. Numerous alternate methods for normalizing partial day samples to represent a total 24-hour collection have since been proposed and used, but no one method is obviously preferred.

  9. Urine drug testing of chronic pain patients. V. Prevalence of propoxyphene following its withdrawal from the United States market.

    PubMed

    Puet, Brandi; DePriest, Anne; Knight, Julie; Heltsley, Rebecca; Black, David L; Caplan, Yale H; Cone, Edward J

    2013-01-01

    Propoxyphene is an opioid analgesic that was surrounded by controversy concerning its safety and efficacy during its lifespan in the US market. Propoxyphene was withdrawn in November of 2010 from the US market and is still being detected one year post-withdrawal in urine specimens from the pain management population. In this study, the prevalence of propoxyphene was determined in a total of 417,914 urine specimens collected from 630 clinics involved in pain management located in 24 states during the period of January 1, 2010, through December 31, 2011. Propoxyphene and norpropoxyphene were measured in urine by a validated liquid chromatography-tandem mass spectrometry procedure with a lower limit of quantitation of 50 ng/mL. The positivity rate for propoxyphene prevalence declined sharply between November and December of 2010 and further declined at a gradual rate, ending in a prevalence of 0.27% (one out of every 370 specimens, n = 25,658) for the month of December 2011. The presented data provide evidence of the dramatic decline in the use of propoxyphene products since their removal from the medical market, and may be beneficial to US urine drug testing programs determining the need for continual monitoring of propoxyphene levels.

  10. Asymptomatic bacteriuria in pregnancy: a diagnostic and therapeutic approach.

    PubMed

    Grio, R; Porpiglia, M; Vetro, E; Uligini, R; Piacentino, R; Minì, D; Marchino, G L

    1994-12-01

    Pregnancy is a predisposing factor for urinary tract infection and pregnant women suffering from this pathology are exposed to dangerous risks which may condition maternal wellbeing and fetal prognosis. The apparently paradoxal finding of a higher incidence of perinatal problems in pregnant women with asymptomatic bacteriuria compared to those with manifest infections may be explained by the fact that the latter are adequately treated, whereas asymptomatic bacteriuria, which is difficult to diagnose, may continue in a subtle form for the entire duration of pregnancy. This emphasises the importance of the early diagnosis of infection using a protocol based on urine tests and urine culture and the adequate treatment of all cases of asymptomatic bacteriuria in order to reduce the incidence of maternal and fetal complications (acute pyelonephritis, increased fetal morbidity and mortality). The choice of the antibiotic to be used must be made on the basis of the urine culture test, the stage of gestation, maternal clinical data and the characteristics of the antibiotic itself (pharmacokinetics, maternal and fetal toxicity). With regard to the treatment protocol, the "single-dose" protocol is currently preferred. After negative urine culture tests, all patients must carry out a complete urine test each month with hormonal and echographic monitoring of the fetoplacental unit.

  11. The excretion of theobromine in Thoroughbred racehorses after feeding compounded cubes containing cocoa husk--establishment of a threshold value in horse urine.

    PubMed

    Haywood, P E; Teale, P; Moss, M S

    1990-07-01

    Thoroughbred geldings were fed racehorse cubes containing a predetermined concentration of theobromine in the form of cocoa husk. They were offered 7 kg of cubes per day, divided between morning and evening feed, and food consumption was monitored. Urinary concentrations of theobromine were determined following the consumption of cubes containing 11.5, 6.6, 2.0 and 1.2 mg per kg of theobromine, to verify whether or not such concentrations would produce positive urine tests. Pre-dose urine samples were collected to verify the absence of theobromine before each experiment. It became apparent from the results of the first three administrations that the limit of detection of theobromine, using such procedures, would be reached at a feed level of about 1 mg per kg theobromine. Therefore the final administration, using cubes containing 1.2 mg per kg theobromine, was singled out for additional analytical work and quantitative procedures were developed to measure urinary concentrations of theobromine. It was anticipated that the results would form a basis for discussions relating to the establishment of a threshold value for theobromine in horse urine. The Stewards of the Jockey Club subsequently gave notice that they had established a threshold level for theobromine in urine of 2 micrograms/ml.

  12. Prevalence of dependent loops in urinary drainage systems in hospitalized patients.

    PubMed

    Danek, Gale; Gravenstein, Nikolaus; Lizdas, David E; Lampotang, Samsun

    2015-01-01

    The purpose of this study was to measure the prevalence and configuration of dependent loops in urinary drainage systems in hospitalized, catheterized adults. The study sample comprised 141 patients with indwelling urinary catheters; subjects were hospitalized at an academic health center in northern Florida. We measured the prevalence of dependent loops in urine drainage systems and the incidence of urine-filled dependent loops over a 3-week period. We measured the heights of the crest (H(c)), trough (H(t)), and, when urine-filled dependent loops were present, the patient-side (H(p)) and bag-side (H(b)) menisci with a laser measurement system. All variables were measured in centimeters. The majority of observed urine drainage systems (85%) contained dependent loops in the drainage tubing and 93.8% of the dependent loops contained urine. H(c) and H(t) averaged 45.1 ± 11.1 and 27 ± 16.7 cm, respectively. Meniscus height difference (H(b) - H(p)) averaged 8.2 ± 5.8 and -12.2 ± 9.9 cm when H(p) < H(b)(65.3%) and H(p) > H(b) (32.7%), respectively. We found that dependent loops are extremely common in urinary drainage systems among hospitalized patients despite the manufacturer recommendations and nursing and hospital policies. Maintaining the urine drainage tubing free of dependent loops would require incorporation into nursing care priorities and workflow as inadvertent force on the tubing, for example, patient movement or nurse contact can change tubing configuration and allow excess drainage tubing to re-form a dependent loop.

  13. Integrated forward osmosis-membrane distillation process for human urine treatment.

    PubMed

    Liu, Qianliang; Liu, Caihong; Zhao, Lei; Ma, Weichao; Liu, Huiling; Ma, Jun

    2016-03-15

    This study demonstrated a forward osmosis-membrane distillation (FO-MD) hybrid system for real human urine treatment. A series of NaCl solutions at different concentrations were adopted for draw solutions in FO process, which were also the feed solutions of MD process. To establish a stable and continuous integrated FO-MD system, individual FO process with different NaCl concentrations and individual direct contact membrane distillation (DCMD) process with different feed temperatures were firstly investigated separately. Four stable equilibrium conditions were obtained from matching the water transfer rates of individual FO and MD processes. It was found that the integrated system is stable and sustainable when the water transfer rate of FO subsystem is equal to that of MD subsystem. The rejections to main contaminants in human urine were also investigated. Although individual FO process had relatively high rejection to Total Organic Carbon (TOC), Total Nitrogen (TN) and Ammonium Nitrogen (NH4(+)-N) in human urine, these contaminants could also accumulate in draw solution after long term performance. The MD process provided an effective rejection to contaminants in draw solution after FO process and the integrated system revealed nearly complete rejection to TOC, TN and NH4(+)-N. This work provided a potential treatment process for human urine in some fields such as water regeneration in space station and water or nutrient recovery from source-separated urine. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Intermediate water recovery system

    NASA Technical Reports Server (NTRS)

    Deckman, G.; Anderson, A. R. (Editor)

    1973-01-01

    A water recovery system for collecting, storing, and processing urine, wash water, and humidity condensates from a crew of three aboard a spacecraft is described. The results of a 30-day test performed on a breadboard system are presented. The intermediate water recovery system produced clear, sterile, water with a 96.4 percent recovery rate from the processed urine. Recommendations for improving the system are included.

  15. Pharmacokinetic Modeling of Intranasal Scopolamine in Plasma Saliva and Urine

    NASA Technical Reports Server (NTRS)

    Wu, L.; Tam, V. H.; Chow, D. S. L.; Putcha, L.

    2015-01-01

    An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS). The bioavailability and pharmacokinetics (PK) were evaluated under IND (Investigational New Drug) guidelines. The aim of the project was to develop a PK model that can predict the relationships among plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trial protocol with INSCOP. Twelve healthy human subjects were administered at three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min to 24 h after dosing and scopolamine concentrations were measured by using a validated LC-MS-MS assay. PK compartmental models, using actual dosing and sampling time, were established using Phoenix (version 1.2). Model selection was based on a likelihood ratio test on the difference of criteria (-2LL (i.e. log-likelihood ratio test)) and comparison of the quality of fit plots. The results: Predictable correlations among scopolamine concentrations in compartments of plasma, saliva and urine were established, and for the first time the model satisfactorily predicted the population and individual PK of INSCOP in plasma, saliva and urine. The model can be utilized to predict the INSCOP plasma concentration by saliva and urine data, and it will be useful for monitoring the PK of scopolamine in space and other remote environments using non-invasive sampling of saliva and/or urine.

  16. Direct tandem mass spectrometry for the simultaneous assay of opioids, cocaine and metabolites in dried urine spots.

    PubMed

    Otero-Fernández, Mara; Cocho, José Ángel; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2013-06-19

    A micro-analytical method based on spotting urine samples (20μL) onto blood/urine spot collection cards followed by air-drying and extraction (dried urine spot, DUS) was developed and validated for the screening/confirmation assay of morphine, 6-methylacetylmorphine (6-MAM), codeine, cocaine and benzoylecgonine (BZE). Acetonitrile (3 mL) was found to be a useful solvent for target extraction from DUSs under an orbital-horizontal stirring at 180 rpm for 10 min. Determinations were performed by direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) under positive electrospray ionization conditions, and by using multiple reaction monitoring (MRM) with one precursor ion/product ion transition for the identification and quantification (deuterated analogs of each target as internal standards) of each analyte. The limits of detection of the method were 0.26, 0.94, 1.5, 1.1, and 2.0 ng mL(-1), for cocaine, BZE, codeine, morphine and 6-MAM, respectively; whereas, relative standard deviations of intra- and inter-day precision were lower than 8 and 11%, respectively, and intra- and inter-day analytical recoveries ranged from 94±4 to 105±3%. The small volume of urine required (20 μL), combined with the simplicity of the analytical technique makes it a useful procedure for screening/quantifying drugs of abuse. The method was successfully applied to the analysis of urine from polydrug abusers. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Simultaneous determination of neonicotinoid insecticides in human serum and urine using diatomaceous earth-assisted extraction and liquid chromatography-tandem mass spectrometry.

    PubMed

    Yamamuro, Tadashi; Ohta, Hikoto; Aoyama, Mika; Watanabe, Daisuke

    2014-10-15

    A rapid and sensitive analytical method was developed for simultaneous determination of eight neonicotinoid insecticides (acetamiprid, clothianidin, dinotefuran, flonicamid, imidacloprid, nitenpyram, thiacloprid and thiamethoxam) and three specific metabolites of acetamiprid (N-desmethylacetamiprid, 5-(N-acetyl-N-methylaminomethyl)-2-chloropyridine and 5-(N-acetylaminomethyl)-2-chloropyridine) in human serum and urine. A diatomaceous earth-assisted extraction using Extrelut NT3 column with chloroform/2-propanol (3:1, v/v) as eluent was selected for the single step cleanup procedure for all the target compounds. Qualitative and quantitative analyses were conducted by liquid chromatography-tandem mass spectrometry with multiple reaction monitoring mode. The limits of detection and the limits of quantification of eleven compounds were in the ranges of 0.1-0.2ng/mL and 0.5-10ng/mL for serum, 0.1-1ng/mL and 1-10ng/mL for urine, respectively. The extraction recoveries were between 80.9% and 101.8% for serum samples, 91.9% and 106% for urine samples. The intra-day RSDs and the inter-day RSDs were less than 11.5% and 13.2% for serum, less than 8.3% and 8.8% for urine. The proposed procedure will be suitable for forensic investigations of human poisoning cases with neonicotinoid insecticides. This is the first report of simultaneous determination of eight neonicotinoids in serum and urine samples. Copyright © 2014. Published by Elsevier B.V.

  18. Acute intoxication and recovery following massive turpentine ingestion: clinical and toxicological data.

    PubMed

    Troulakis, G; Tsatsakis, A M; Tzatzarakis, M; Astrakianakis, A; Dolapsakis, G; Kostas, R

    1997-06-01

    Reports of acute turpentine intoxication, particularly containing toxicological data, are poorly verified in the literature. This report regards the intentional massive ingestion of turpentine solution in an elderly woman who developed mainly central nervous system manifestations, then had an impressive and quick total recovery although the initial prognosis was very bad. Blood and urine levels of turpentine were monitored using gas chromatography and at the early toxicogenic stage were 28 micrograms/mL and 15 micrograms/mL respectively. Gastric fluid analysis on admission to the hospital revealed the presence of approximately 200 mL turpentine in the intestine. A review of earlier reports is given.

  19. PBG urine test

    MedlinePlus

    ... test. Alternative Names Porphobilinogen test; Porphyria - urine; PBG Images Male urinary system References Fuller SJ, Wiley JS. Heme biosynthesis and its disorders: porphyrias and sideroblastic ...

  20. Estimating lifetime risk from spot biomarker data and intra‐class correlation coefficients (ICC)

    EPA Science Inventory

    Human biomarker measurements in tissues including blood, breath, and urine can serve as efficient surrogates for environmental monitoring because a single biological sample integrates personal exposure across all environmental media and uptake pathways. However, biomarkers repres...

  1. A pilot study on the use of natural calcium isotope (44Ca/40Ca) fractionation in urine as a proxy for the human body calcium balance.

    PubMed

    Heuser, Alexander; Eisenhauer, Anton

    2010-04-01

    We explored the possibility of using natural calcium (Ca) isotope variations in the urine (delta(44/40)Ca(urine)) as a proxy for the Ca balance in the human body. We chose two test persons extremely different in their health status, gender and age (4-year-old healthy boy and a 60-year-old woman known to suffer from osteoporosis). During a 5 day interval the Ca isotope composition of the individual diet (delta(44/40)Ca(diet)) was monitored for both test persons to be in general agreement to the Ca isotope composition of the normal western European diet ( approximately -1.02+/-0.1 per thousand). However, measurements showed that (1) delta(44/40)Ca(urine) of both test persons are approximately 1.37 and approximately 2.49 per thousand, respectively, heavier than delta(44/40)Ca(diet) and that (2) the delta(44/40)Ca(urine-boy) is approximately 1.1 per thousand heavier when compared to the value of the woman. The individual offset between diet and test persons is interpreted to reflect individual Ca reabsorption rates in the kidneys being the result of Rayleigh type Ca isotope fractionation related to the partitioning of Ca between the glomerular filtrate and filtered residue. The relative difference between delta(44/40)Ca(urine-boy) and delta(44/40)Ca(urine-woman) of approximately 1.1 per thousand may reflect individual differences in the balance of bone mineralization and demineralization processes related to age, gender and health status. By arbitrarily defining an equilibrium value for Delta(44/40)Ca(diet-urine) of -1.93 per thousand being the arithmetic mean of delta(44/40)Ca(urine) for both test persons the measured delta(44/40)Ca(urine) values may be applied to model the individual bone mineralization and demineralization processes in a qualitative way. Note, second order influences of intestinal Ca absorption during sequestration of Ca between intestine and blood have to be subject of further studies. Copyright 2009 Elsevier Inc. All rights reserved.

  2. Urine analysis concerning xenon for doping control purposes.

    PubMed

    Thevis, Mario; Piper, Thomas; Geyer, Hans; Schaefer, Maximilian S; Schneemann, Julia; Kienbaum, Peter; Schänzer, Wilhelm

    2015-01-15

    On September 1(st) 2014, a modified Prohibited List as established by the World Anti-Doping Agency (WADA) became effective featuring xenon as a banned substance categorized as hypoxia-inducible factor (HIF) activator. Consequently, the analysis of xenon from commonly provided doping control specimens such as blood and urine is desirable, and first data on the determination of xenon from urine in the context of human sports drug testing, are presented. In accordance to earlier studies utilizing plasma as doping control matrix, urine was enriched to saturation with xenon, sequentially diluted, and the target analyte was detected as supported by the internal standard d6 -cyclohexanone by means of gas chromatography/triple quadrupole mass spectrometry (GC/MS/MS) using headspace injection. Three major xenon isotopes at m/z 128.9, 130.9 and 131.9 were targeted in (pseudo) selected reaction monitoring mode enabling the unambiguous identification of the prohibited substance. Assay characteristics including limit of detection (LOD), intraday/interday precision, and specificity as well as analyte recovery under different storage conditions were determined. Proof-of-concept data were generated by applying the established method to urine samples collected from five patients before, during and after (up to 48 h) xenon-based general anesthesia. Xenon was traceable in enriched human urine samples down to the detection limit of approximately 0.5 nmol/mL. The intraday and interday imprecision values of the method were found below 25%, and specificity was demonstrated by analyzing 20 different blank urine samples that corroborated the fitness-for-purpose of the analytical approach to unequivocally detect xenon at non-physiological concentrations in human urine. The patients' urine specimens returned 'xenon-positive' test results up to 40 h post-anesthesia, indicating the limits of the expected doping control detection window. Since xenon has been considered a prohibited substance according to WADA regulations in September 2014, its analysis from common specimens of routine sports drug testing is desirable. In previous studies, its traceability in whole blood and plasma was shown, and herein a complementary approach utilizing doping control urine samples for the GC/MS/MS analysis of xenon was reported. Copyright © 2014 John Wiley & Sons, Ltd.

  3. 21 CFR 862.1550 - Urinary pH (nonquantitative) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (nonquantitative) test system is a device intended to estimate the pH of urine. Estimations of pH are used to evaluate the acidity or alkalinity of urine as it relates to numerous renal and metabolic disorders and in...

  4. 21 CFR 862.1550 - Urinary pH (nonquantitative) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (nonquantitative) test system is a device intended to estimate the pH of urine. Estimations of pH are used to evaluate the acidity or alkalinity of urine as it relates to numerous renal and metabolic disorders and in...

  5. [Blood anticoagulation system and urine fibrinolysis in newborn infants with suppurative-inflammatory diseases].

    PubMed

    Samsygina, G A; Vykhristiuk, O F

    1989-01-01

    The anticoagulative blood system, blood and urine fibrinolysis were studied in 95 children with pyo-inflammatory diseases (PID) and in 56 normal neonates aged 2 to 28 days. The patients afflicted with PID were distributed into 3 groups; group I included patients with uneventful localized PID, group II consisted of patients with grave PID, and group III of patients with sepsis. Hemostasis and urine fibrinolysis were compared according to 20 indicators. The intensity and involvement of certain components of the fibrinolytic and anticoagulative blood systems in PID turned out different and were dependent on the disease gravity.

  6. Impact of order set design on urine culturing practices at an academic medical centre emergency department.

    PubMed

    Munigala, Satish; Jackups, Ronald R; Poirier, Robert F; Liang, Stephen Y; Wood, Helen; Jafarzadeh, S Reza; Warren, David K

    2018-01-20

    Urinalysis and urine culture are commonly ordered tests in the emergency department (ED). We evaluated the impact of removal of order sets from the 'frequently ordered test' in the computerised physician order entry system (CPOE) on urine testing practices. We conducted a before (1 September to 20 October 2015) and after (21 October to 30 November 2015) study of ED patients. The intervention consisted of retaining 'urinalysis with reflex to microscopy' as the only urine test in a highly accessible list of frequently ordered tests in the CPOE system. All other urine tests required use of additional order screens via additional mouse clicks. The frequency of urine testing before and after the intervention was compared, adjusting for temporal trends. During the study period, 6499 (28.2%) of 22 948 ED patients had ≥1 urine test ordered. Urine testing rates for all ED patients decreased in the post intervention period for urinalysis (291.5 pre intervention vs 278.4 per 1000 ED visits post intervention, P=0.03), urine microscopy (196.5vs179.5, P=0.001) and urine culture (54.3vs29.7, P<0.001). When adjusted for temporal trends, the daily culture rate per 1000 ED visits decreased by 46.6% (-46.6%, 95% CI -66.2% to -15.6%), but urinalysis (0.4%, 95% CI -30.1 to 44.4%), microscopy (-6.5%, 95% CI -36.0% to 36.6%) and catheterised urine culture rates (17.9%, 95% CI -16.9 to 67.4) were unchanged. A simple intervention of retaining only 'urinalysis with reflex to microscopy' and removing all other urine tests from the 'frequently ordered' window of the ED electronic order set decreased urine cultures ordered by 46.6% after accounting for temporal trends. Given the injudicious use of antimicrobial therapy for asymptomatic bacteriuria, findings from our study suggest that proper design of electronic order sets plays a vital role in reducing excessive ordering of urine cultures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. A method to detect transfected chloramphenicol acetyltransferase gene expression in intact animals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narayanan, R.; Jastreboff, M.M.; Chiu, Chang Fang

    1988-01-01

    A rapid procedure is described for assaying chloramphenicol acetyltransferase enzyme activity in intact animals following transfection of the RSV CAT plasmid into mouse bone marrow cells by electroporation. The reconstituted mice were injected with ({sup 14}C)chloramphenicol and ethyl acetate extracts of 24-h urine samples were analyzed by TLC autoradiography for the excretion of {sup 14}C-labeled metabolites. CAT expression in vivo can be detected by the presence of acetylated {sup 14}C-labeled metabolites in the urine within 1 week after bone marrow transplantation and, under the conditions described, these metabolites can be detected for at least 3 months. CAT expression in intactmore » mice as monitored by the urine assay correlates with the CAT expression in the hematopoietic tissues assayed in vitro. This method offers a quick mode of screening for introduced CAT gene expression in vivo without sacrificing the mice.« less

  8. Determination of the MRI contrast agent Gd-DTPA by SEC-ICP-MS.

    PubMed

    Loreti, Valeria; Bettmer, Jörg

    2004-08-01

    The simultaneous determination of Gd(3+) and Gd-DTPA (DTPA: diethylenetriamino-pentaacetic acid), often used as contrast agent, is described. The proposed approach combines size-exclusion chromatography (SEC) and inductively coupled plasma-mass spectrometry (ICP-MS) for element-selective detection in order to determine also high-molecular Gd-complexes if present. This method was applied to the analysis of urine samples of a patient to whom Gd-DTPA was intravenously administered. The results showed that no conversion or adsorption of Gd-DTPA could be observed in any sample, even free Gd(3+) could not be detected. Urine excretion behaviour was monitored and it was proved that Gd-DTPA was almost completely (>99%) excreted by urination within one day. Traces of Gd-DTPA could be measured in hair samples, but extraction with tetramethylammonium hydroxide (TMAH) resulted in degradation of Gd-DTPA.

  9. A urine-fuelled soil-based bioregenerative life support system for long-term and long-distance manned space missions.

    PubMed

    Maggi, Federico; Tang, Fiona H M; Pallud, Céline; Gu, Chuanhui

    2018-05-01

    A soil-based cropping unit fuelled with human urine for long-term manned space missions was investigated with the aim to analyze whether a closed-loop nutrient cycle from human liquid wastes was achievable. Its ecohydrology and biogeochemistry were analysed in microgravity with the use of an advanced computational tool. Urine from the crew was used to supply primary (N, P, and K) and secondary (S, Ca and Mg) nutrients to wheat and soybean plants in the controlled cropping unit. Breakdown of urine compounds into primary and secondary nutrients as well as byproduct gases, adsorbed, and uptake fractions were tracked over a period of 20 years. Results suggested that human urine could satisfy the demand of at least 3 to 4 out of 6 nutrients with an offset in pH and salinity tolerable by plants. It was therefore inferred that a urine-fuelled life support system can introduce a number of advantages including: (1) recycling of liquids wastes and production of food; (2) forgiveness of neglect as compared to engineered electro-mechanical systems that may fail under unexpected or unplanned conditions; and (3) reduction of supply and waste loads during space missions. Copyright © 2018 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.

  10. Uromodulin: a new biomarker of fetal renal function?

    PubMed

    Botelho, Thais Emanuelle Faria; Pereira, Alamanda Kfoury; Teixeira, Patrícia Gonçalves; Lage, Eura Martins; Osanan, Gabriel Costa; Silva, Ana Cristina Simões E

    2016-12-01

    Obstructive uropathies are main diseases affecting the fetus. Early diagnosis allows to establish the appropriate therapy to minimize the risk of damage to kidney function at birth. Biochemical markers have been used to predict the prognosis of renal function in fetuses. Uromodulin, also known by Tamm-Horsfall protein (THP) is exclusively produced in the kidneys and in normal conditions is the protein excreted in larger amounts in human urine. It plays important roles in kidneys and urinary tract. Also it participates in ion transport processes, interact with various components of the immune system and has a role in defense against urinary tract infections. Moreover, this protein was proved to be a good marker of renal function in adult patients with several renal diseases. To evaluate if uromodulin is produced and eliminated by the kidneys during fetal life by analyzing fetal urine and amniotic fluid and to establish correlation with biochemical parameter of renal function already used in Fetal Medicine Center at the Clinic Hospital of UFMG (CEMEFE/HC). Between 2013 and 2015, were selected 29 fetuses with indication of invasive tests for fetal diagnosis in monitoring at the CEMEFE/HC. The determination of uromodulin was possible and measurable in all samples and showed statistically significant correlation with the osmolarity. There was a tendency of lower levels of Uromodulin values in fetuses with severe renal impairment prenatally. Thus, high levels of this protein in fetal amniotic fluid or fetal urine dosages possibly mean kidney function preserved.

  11. Simultaneous determination of 18 tetrahydrocorticosteroid sulfates in human urine by liquid chromatography/electrospray ionization-tandem mass spectrometry.

    PubMed

    Mitamura, Kuniko; Satoh née Okihara, Rika; Kamibayashi, Mami; Sato, Kanta; Iida, Takashi; Ikegawa, Shigeo

    2014-07-01

    A liquid chromatography (LC)/electrospray ionization (ESI)-mass spectrometry (MS) method for the direct determination of eighteen tetrahydrocorticosteroid sulfates in human urine has been developed. The analytes were 3- and 21-monosulfates and 3,21-disulfates of tetrahydrocortisol (THF), tetrahydrocortisone (THE), tetrahydro-11-deoxycortisol (THS), and their corresponding 5α-H stereoisomers. The mass spectrometric behavior of these sulfates in negative-ion ESI-MS/MS revealed the production of intense structure specific product ions within the same group of sulfates and permitted distinction between regioisomeric sulfates by collision-induced fragmentation with the MS/MS technique using a linear ion-trap instrument. For the quantitative analysis, selected reaction monitoring analysis in the negative-ion detection mode using triple-stage quadrupole mass spectrometer was performed by monitoring transitions from [M-H](-) to the most abundant product ion of each tetrahydrocorticosteroid sulfate. After addition of 3- and 21-monosulfates of [2,2,3β,4,4-d5]-THF, -THE, and -THS as internal standards, urine sample was applied to a solid phase extraction using a lipophilic-weak anion exchange cartridge column, and then analyzed by LC/ESI-MS/MS. The method had satisfactory performance in terms of intra- and inter-assay precision (less than 9.7% and 9.6%, respectively), and accuracy (91.2-108.2%). The limit of quantification was lower than 2.5 ng/mL for all sulfates examined. We applied this method to determine the concentration of eighteen tetrahydrocorticosteroid sulfates in the urine of healthy subjects. Thus, we have developed a sensitive, precise and accurate assay for urinary tetrahydrocorticosteroid sulfates that should be useful for clinical and biological studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Analysis of anabolic androgenic steroids in urine by full-capillary sample injection combined with a sweeping CE stacking method.

    PubMed

    Wang, Chun-Chi; Cheng, Shu-Fang; Cheng, Hui-Ling; Chen, Yen-Ling

    2013-02-01

    This study describes an on-line stacking CE approach by sweeping with whole capillary sample filling for analyzing five anabolic androgenic steroids in urine samples. The five anabolic steroids for detection were androstenedione, testosterone, epitestosterone, boldenone, and clostebol. Anabolic androgenic steroids are abused in sport doping because they can promote muscle growth. Therefore, a sensitive detection method is imperatively required for monitoring the urine samples of athletes. In this research, an interesting and reliable stacking capillary electrophoresis method was established for analysis of anabolic steroids in urine. After liquid-liquid extraction by n-hexane, the supernatant was dried and reconstituted with 30 mM phosphate buffer (pH 5.00) and loaded into the capillary by hydrodynamic injection (10 psi, 99.9 s). The stacking and separation were simultaneously accomplished at -20 kV in phosphate buffer (30 mM, pH 5.0) containing 100 mM sodium dodecyl sulfate and 40 % methanol. During the method validation, calibration curves were linear (r≥0.990) over a range of 50-1,000 ng/mL for the five analytes. In the evaluation of precision and accuracy for this method, the absolute values of the RSD and the RE in the intra-day (n=3) and inter-day (n=5) analyses were all less than 6.6 %. The limit of detection for the five analytes was 30 ng/mL (S/N=5, sampling 99.9 s at 10 psi). Compared with simple MECK, this stacking method possessed a 108- to 175-fold increase in sensitivity. This simple and sensitive stacking method could be used as a powerful tool for monitoring the illegal use of doping.

  13. Hydration status and the diuretic action of a small dose of alcohol.

    PubMed

    Hobson, Ruth M; Maughan, Ronald J

    2010-01-01

    This study was conducted to examine the effect of consuming a dilute alcohol solution (weak beer) on urine production in euhydrated and hypohydrated individuals. Twelve males completed an intermittent cycle protocol in hot (35.1 +/- 0.3 degrees C), humid (68 +/- 2%) conditions to dehydrate by 1.9 +/- 0.3% body mass in the evening. Twice they were then fed and rehydrated, while on two other occasions they were fed the same meal but remained hypohydrated. The following morning they were given 1 l of beer to drink. On two occasions the beer was alcohol-free, while on the other two occasions the same beer contained 4% ethanol. Participants remained in the laboratory for monitoring over the subsequent 4 h. Blood and urine samples were taken prior to dehydration, prior to drink administration and once every hour of the monitoring period. No difference existed in the volume of urine produced between the alcohol (261 +/- 138 ml; mean +/- SD) and non-alcohol (174 +/- 61 ml) beer when hypohydrated (P = 0.057), but there was a difference when euhydrated (1279 +/- 256 vs 1121 +/- 148 ml alcohol and non-alcohol, respectively; P < 0.001). Unsurprisingly, more urine was produced on both euhydrated trials than either of the hypohydrated trials (P < 0.001). Blood alcohol concentration was elevated (P < 0.001) 1 h after drinking to 7.1 +/- 1.8 and 6.0 +/- 2.7 mmol/l (hypohydrated and euhydrated, respectively) on the alcohol trials. Serum osmolality was higher 1 h after drinking on both the alcohol trials (303 +/- 5 and 298 +/- 5 mosmol/l) than on their non-alcohol, equivalent hydration trials (290 +/- 8 and 284 +/- 5 mosmol/l hypohydrated and euhydrated, respectively; P < 0.001). These results suggest that the diuretic action of alcohol is blunted when the body is hypohydrated.

  14. Application of gas chromatography-tandem mass spectrometry for the determination of amphetamine-type stimulants in blood and urine.

    PubMed

    Woźniak, Mateusz Kacper; Wiergowski, Marek; Aszyk, Justyna; Kubica, Paweł; Namieśnik, Jacek; Biziuk, Marek

    2018-01-30

    Amphetamine, methamphetamine, phentermine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxy-N-ethylamphetamine (MDEA) are the most popular amphetamine-type stimulants. The use of these substances is a serious societal problem worldwide. In this study, a method based on gas chromatography-tandem mass spectrometry (GC-MS/MS) with simple and rapid liquid-liquid extraction (LLE) and derivatization was developed and validated for the simultaneous determination of the six aforementioned amphetamine derivatives in blood and urine. The detection of all compounds was based on multiple reaction monitoring (MRM) transitions. The most important advantage of the method is the minimal sample volume (as low as 200μL) required for the extraction procedure. The validation parameters, i.e., the recovery (90.5-104%), inter-day accuracy (94.2-109.1%) and precision (0.5-5.8%), showed the repeatability and sensitivity of the method for both matrices and indicated that the proposed procedure fulfils internationally established acceptance criteria for bioanalytical methods The procedure was successfully applied to the analysis of real blood and urine samples examined in 22 forensic toxicological cases. To the best of our knowledge, this is the first work presenting the use of GC-MS/MS for the determination of amphetamine-type stimulants in blood and urine. In view of the low limits of detection (0.09-0.81ng/mL), limits of quantification (0.26-2.4ng/mL), and high selectivity, the procedure can be applied for drug monitoring in both fatal and non-fatal intoxication cases in routine toxicology analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Exposure to 4,4'-methylenediphenyl diisocyanate (MDI) during moulding of rigid polyurethane foam: determination of airborne MDI and urinary 4,4'-methylenedianiline (MDA).

    PubMed

    Kääriä, K; Hirvonen, A; Norppa, H; Piirilä, P; Vainio, H; Rosenberg, C

    2001-04-01

    Occupational exposure to 4,4'-methylenediphenyl diisocyanate (MDI) was measured during moulding of rigid polyurethane foam. The aim of the study was to find out whether an MDI-derived urinary amine metabolite could be detected in the urine of workers exposed to apparently low levels of MDI. Airborne MDI was sampled on 1-(2-methoxyphenyl)-piperazine (2MP)-impregnated glass fibre filters and determined by high-performance liquid chromatography (HPLC) using ultraviolet (UV) and electrochemical (EC) detection. The limit of detection of MDI was 3 ng ml-1 for a 20 microliters injection. The precision of sample preparation, expressed as relative standard deviation (RSD), was 1.3% with UV detection and 2.1% with EC detection at a concentration of 70 ng MDI ml-1 (n = 6). The 2MP-MDI derivative was stable at +4 degrees C up to eight weeks. The accuracy of the method was validated in an international quality control programme. Workers (n = 57) from three different factories participated in the study. Urinary 4,4'-methylenedianiline (MDA) metabolite was determined after acid hydrolysis as heptafluorobutyric anhydride derivatives by gas chromatography-mass spectrometry using chemical ionisation and monitoring negative ions. The limit of detection in urine was 0.2 nmol l-1. The precision of six analyses for a urine sample spiked to a concentration of 1 nmol l-1 was 29% (RSD). The MDI concentrations were below the limit of detection in most (64%) of the air samples collected in the worker's breathing zone. Still, detectable amounts of MDA were found in 97% of the urine samples. Monitoring of urinary MDA appears to be an appropriate method of assessing MDI exposure in work environments with low or undetectable MDI concentrations in the workplace air.

  16. Sensitive and simple determination of zwitterionic morphine in human urine based on liquid-liquid micro-extraction coupled with surface-enhanced Raman spectroscopy.

    PubMed

    Yu, Borong; Cao, Chentai; Li, Pan; Mao, Mei; Xie, Qiwen; Yang, Liangbao

    2018-08-15

    Morphine, a kind of illicit drugs, is also one of the main heroin metabolites. In consideration of a noninvasive way to monitor and identify drug abuse during forensic cases, the urine samples are usually detected. Here, colloidal gold nanorods (Au NRs) were introduced to act as active substrate, because of the strong optical extinction and spectral tunability of the longitudinal surface plasmon resonance (SPR). Thus, well surface-enhanced Raman spectra of morphine even at low concentrations could be obtained by portable Raman spectrometer. For the complex matrix environment of urine, liquid-liquid micro-extraction (LLME), a simple and inexpensive pretreatment, was employed to avoid the interferences. And then, the coupled surface-enhanced Raman spectroscopy (SERS) can give full play to the advantages of high sensitivity and unique spectroscopic fingerprint. According to the zwitterionic structure and physicochemical parameters of morphine molecules, the pH value of urine sample was adjusted to about 9 by buffer solution (KOH/NaB 4 O 7 ) and the mixture of chloroform and isopropyl alcohol (V/V=9:1) was chosen as extractant. Moreover, such pretreatment was proved to be appropriate for separation and concentration of morphine from urine. The developed LLME-SERS method could provide a detection limit less than 1 ppm in the human urine environment and the whole process of detection just needed take 5-6 min. What's more, the results of urine samples from heroin users exhibited application value of the proposed technique. The excellent performance makes it promising to become a rapid, reliable, and on-spot analyzer, especially for public safety and healthcare. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Analysis of 3,5-dichloroaniline as a biomarker of vinclozolin and iprodione in human urine using liquid chromatography/triple quadrupole mass spectrometry.

    PubMed

    Lindh, Christian H; Littorin, Margareta; Amilon, Asa; Jönsson, Bo A G

    2007-01-01

    The fungicides vinclozolin and iprodione are widely used in agriculture. These pesticides are dicarboximide fungicides containing the common moiety 3,5-dichloroaniline (3,5-DCA). It has been suggested that low-level exposures to such compounds may be associated with adverse health effects such as endocrine disruption. In this study a method using liquid chromatography/triple quadrupole mass spectrometry (LC/MS/MS) was developed for the analysis of 3,5-DCA as a biomarker of exposure to these fungicides in human urine. The urine samples were treated by basic hydrolysis to degrade the fungicides, their metabolites and conjugates to 3,5-DCA. The 3,5-DCA was then extracted using toluene and derivatized using pentafluoropropionic anhydride (PFPA). Analysis of the derivative was carried out using selected reaction monitoring (SRM) in the negative ion mode. Quantification of the derivative was performed using [(13)C(6)]-labeled 3,4-DCA as an internal standard with good precision and linearity in the range 0.1-200 ng/mL urine. The limit of detection was determined to be 0.1 ng/mL. The metabolites in urine were found to be stable during storage at -20 degrees C. To validate 3,5-DCA as a biomarker the method was applied in a human experimental exposure to iprodione and vinclozolin. Two healthy volunteers received 200 microg single oral doses of each pesticide followed by urine sampling during 72-120 h post-exposure. Between 78-107% of the dose was recovered as 3,5-DCA in the urine after exposure. Copyright (c) 2007 John Wiley & Sons, Ltd.

  18. Evidence for false-positive results for boldenone testing of veal urine due to faecal cross-contamination during sampling.

    PubMed

    Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G

    2004-08-01

    European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.

  19. Effects of childbirth on podocyturia in women with normotensive, uncomplicated pregnancies.

    PubMed

    Furuta, Itsuko; Zhai, Tianyue; Umazume, Takeshi; Ishikawa, Satoshi; Nakagawa, Kinuko; Kojima, Takashi; Yamada, Takahiro; Morikawa, Mamoru; Minakami, Hisanori

    2017-06-01

    Changes in hemodynamics and blood pressure occur shortly before and after childbirth regardless of the mode of delivery. This study aimed to test the hypothesis that parturition induces a temporal increase in podocyturia monitored by podocyte-specific protein podocin mRNA expression levels (Pod-mRNA). A total of 105 urine specimens, consisting of 43 and 62 from 18 and 20 otherwise healthy women with vaginal delivery (VD) and elective cesarean delivery (ECS), respectively, were studied. Determination of urine protein and creatinine (Cr) concentrations and quantitative analyses of Pod-mRNA, nephrin mRNA (Nep-mRNA), synaptopodin mRNA (Syn-mRNA), and aquaporin 2 mRNA expression were performed using RT-PCR in pelleted urine samples. Levels of mRNA expression were corrected by urine Cr concentration. Podocyturia increased significantly, concomitant with a significantly decreased Nep:Pod-mRNA ratio (NPR) in the urine, collected immediately before or after childbirth regardless of the delivery mode compared with urine collected before commencement of labor or on postpartum day 3 or later. Podocyturia was significantly negatively correlated with NPR [correlation coefficient ( r ) = -0.614/-0.750 for VD/ECS women, respectively], as well as the Syn:Pod-mRNA ratio. Systolic blood pressure exceeded 140 mmHg during labor in 50% of VD women, and mean arterial pressure was significantly positively correlated with podocyturia during labor in VD women ( r  = 0.733). Thus parturition induces a transient increase in urine podocytes with reduced Nep- and Syn-mRNA expressions. Glomerular podocytes with reduced Nep- and Syn-mRNA levels were suggested to be likely to detach from the glomerular basement membrane around childbirth. Copyright © 2017 the American Physiological Society.

  20. Implementation of bioassay methods to improve assessment of incorporated radionuclides.

    PubMed

    Oeh, U; Andrasi, A; Bouvier-Capely, C; De Carlan, L; Fischer, H; Franck, D; Höllriegl, V; Li, W B; Ritt, J; Roth, P; Schmitzer, Ch; Wahl, W; Zombori, P

    2007-01-01

    The present work which was carried out in the framework of an EU project (IDEA: Internal Dosimetry-Enhancements in Application; Contract Number: FIKR CT2001 00164) shall provide commonly acceptable guidelines for optimum performance of ICP-MS measurements with focus on urinary measurements of uranium, thorium and actinides. From the results of this work it is recommended that, whenever feasible, 24 h urine sampling should be conducted to avoid large uncertainties in the quantitation of daily urinary excretion values. For storage, urine samples should be acidified and kept frozen before analysis. Measurement of total uranium in urine by ICP-MS at physiological levels (<10 ng.l(-1)) requires no sample preparation besides UV photolysis and/or dilution. For the measurement of thorium in urine by ICP-MS, it can be concluded, that salt removal from the urine samples is not recommended. For the measurement of actinides in urine it is shown that ICP-MS is well-suited and a good alternative to alpha-spectrometry for isotopes with T1/2>5x10(4) years. In general, ICP-MS measurements are an easy, fast and cost-saving methodology. New improved measuring techniques (HR-SF-ICP-MS) with detection limits in urine of 150 pg.l(-1) (1.9 microBq.l(-1)) for 238U, 30 pg.l(-1) (2.4 microBq.l(-1)) for 235U and 100 pg.l(-1) (0.4 microBq.l(-1)) for (232)Th, respectively, meet all necessary requirements. This method should therefore become the routine technique for incorporation monitoring of workers and of members of the general public, in particular for uranium contamination.

  1. Development of a prototype fluid volume measurement system. [for urine volume measurement on space missions

    NASA Technical Reports Server (NTRS)

    Poppendiek, H. F.; Sabin, C. M.; Meckel, P. T.

    1974-01-01

    The research is reported in applying the axial fluid temperature differential flowmeter to a urine volume measurement system for space missions. The fluid volume measurement system is described along with the prototype equipment package. Flowmeter calibration, electronic signal processing, and typical void volume measurements are also described.

  2. Automated biowaste sampling system urine subsystem operating model, part 1

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Rosen, F.

    1973-01-01

    The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.

  3. Effect of 2 Bedding Materials on Ammonia Levels in Individually Ventilated Cages

    DTIC Science & Technology

    2016-01-01

    primarily from urease -positive bacteria, which metabolize urea from the urine and feces of the animals.8 Therefore, am- monia levels are...proportional to the amounts of wet urine and urease -positive bacteria present in the cage. IVC systems help to reduce the levels of both urine and urease

  4. Postinhalation kinetics of metabolism of americium-241 and absorbed doses in organs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buldakov, L.A.; Kalmykova, Z.I.

    1979-12-01

    The metabolism of soluble americium-241 compounds administered to dogs by inhalation was studied over a period of 6.5 years. The rate of excretion of americium-241 in feces and urine, organ uptake, and survival were monitored.

  5. Is there any change in the prevalence of intestinal and urinary parasitosis among "non-permanent resident" students in Tunisia ?

    PubMed

    Trabelsi, Sonia; Bouchakoua, Myiram; Aouinet, Amira; Sellami, Amira; Khaled, Samira

    2012-07-01

    Intestinal parasitosis are cosmopolitan affections, often related to the fecal peril. However urinary bilharziosis is a disease eliminated in Tunisia. As part of monitoring the emergence and re-emergence of intestinal parasitosis and urinary bilharziasis, foreign students benefit from parasitological systematic monitoring stool and urine during their enrollment to the University. To study the prevalence of various intestinal parasitosis and urinary bilharziasis among non permanent resident students in Tunisia. A retrospective survey was carried at the Laboratory of Parasitology- Mycology of Charles Nicolle Hospital of Tunis during the inscription period of 6 university years 2005-2010. 328 students profited from a parasitological examination of stool and urine. 144 students (43.9%) harbored intestinal parasites. More than one parasite was detected in 69 students (47.9%). Intestinal protozoa were the majority of identified parasites (96.9%). 9.7% of identified parasites were pathogenic. Three cases (0.91%) of urinary bilharziasis were diagnosed. The prevalence of intestinal and urinary parasitism among the "non-permanent residents" students in Tunisia has not changed. This justifies a systematic parasitologic monitoring for students coming from areas of high endemicity of parasitosis in order to avoid the introduction of these.

  6. The interference of medical radionuclides with occupational in vivo gamma spectrometry.

    PubMed

    Kol, R; Pelled, O; Canfi, A; Gilad, Y; German, U; Laichter, Y; Lantsberg, S; Fuksbrauner, R; Gold, B

    2003-06-01

    Radiation workers undergo routine monitoring for the evaluation of external and internal radiation exposures. The monitoring of internal exposures involves gamma spectrometry of the whole body (whole body counting) and measurements of excreta samples. Medical procedures involving internal administration of radioactive radionuclides are widely and commonly used. Medical radionuclides are typically short-lived, but high activities are generally administered, whereas occupational radionuclides are mostly long-lived and, if present, are found generally in relatively smaller quantities. The aim of the present work was to study the interference of some common medical radionuclides (201Tl, 9mTc, 57Co, and 131I) with the detection of internal occupational exposures to natural uranium and to 137Cs. Workers having undergone a medical procedure with one of the radionuclides mentioned above were asked to give frequent urine samples and to undergo whole body and thyroid counting with phoswich detectors operated at the Nuclear Research Center Negev. Urine and whole body counting monitoring were continued as long as radioactivity was detectable by gamma spectrometry. The results indicate that the activity of medical radionuclides may interfere with interpretation of occupational intakes for months after administration.

  7. Flight equipment supporting metabolic experiments on SLS-1

    NASA Technical Reports Server (NTRS)

    Leach, Carolyn S.; Inners, L. D.

    1991-01-01

    Five experiments in different aspects of human metabolism will be performed on Spacelab Life Sciences-1. Nine items of equipment from the Life Sciences Laboratory Equipment inventory will be used: the rack-mounted centrifuge, the hematocrit centrifuge, the low-gravity centrifuge, a body-mass measurement device, a urine monitoring system, the Spacelab refrigerator/freezer, the Orbiter refrigerator, an in-flight blood collection system, and a pocket voice recorder. In addition, each experiment will require some specialized equipment such as incubators and culture blocks for an immunology experiment, and tracers for a fluid and electrolyte experiment and a hematology experiment. The equipment for these experiments has been developed over many years, in some cases since the Skylab program in the early 1970s, and has been certified for use on the Space Shuttle.

  8. A Wireless Self-Powered Urinary Incontinence Sensor System

    NASA Astrophysics Data System (ADS)

    Tanaka, Ami; Utsunomiya, Fumiyasu; Douseki, Takakuni

    A self-powered urinary incontinence sensor system consisting of a urine-activated coin battery and a wireless transmitter has been developed as an application for wireless biosensor networks. The urine-activated battery makes possible both the sensing of urine leakage and self-powered operation. An intermittent power-supply circuit that uses an electric double-layer capacitor (EDLC) with a small internal resistance suppresses the supply voltage drop due to the large internal resistance of the battery. This circuit and a 1-V surface acoustic wave (SAW) oscillator reduce the power dissipation of a wireless transmitter. The SAW oscillator quickly responds to the on-off control of the power supply, which is suitable for intermittent operation. To verify the effectiveness of the circuit scheme, the authors fabricated a prototype sensor system. When the volume of urine is 0.2 ml, the battery outputs a voltage of over 1.3 V; and the sensor system can transmit signals over a distance of 5 m.

  9. Evaluating levels and health risk of heavy metals in exposed workers from surgical instrument manufacturing industries of Sialkot, Pakistan.

    PubMed

    Junaid, Muhammad; Hashmi, Muhammad Zaffar; Malik, Riffat Naseem

    2016-09-01

    The study aimed to monitor heavy metal (chromium, Cr; cadmium, Cd; nickel, Ni; copper, Cu; lead, Pb; iron, Fe; manganese, Mn; and zinc, Zn) footprints in biological matrices (urine, whole blood, saliva, and hair), as well as in indoor industrial dust samples, and their toxic effects on oxidative stress and health risks in exposed workers. Overall, blood, urine, and saliva samples exhibited significantly higher concentrations of toxic metals in exposed workers (Cr; blood 16.30 μg/L, urine 58.15 μg/L, saliva 5.28 μg/L) than the control samples (Cr; blood 5.48 μg/L, urine 4.47 μg/L, saliva 2.46 μg/L). Indoor industrial dust samples also reported to have elevated heavy metal concentrations, as an example, Cr quantified with concentration of 299 mg/kg of dust, i.e., more than twice the level of Cr in household dust (136 mg/kg). Superoxide dismutase (SOD) level presented significant positive correlation (p ≤ 0.01) with Cr, Zn, and Cd (Cr > Zn > Cd) which is an indication of heavy metal's associated raised oxidative stress in exposed workers. Elevated average daily intake (ADI) of heavy metals resulted in cumulative hazard quotient (HQ) range of 2.97-18.88 in workers of different surgical units; this is an alarming situation of health risk implications. Principal component analysis-multiple linear regression (PCA-MLR)-based pie charts represent that polishing and cutting sections exhibited highest metal inputs to the biological and environmental matrices than other sources. Heavy metal concentrations in biological matrices and dust samples showed a significant positive correlation between Cr in dust, urine, and saliva samples. Current study will help to generate comprehensive base line data of heavy metal status in biomatrices and dust from scientifically ignored industrial sector. Our findings can play vital role for health departments and industrial environmental management system (EMS) authorities in policy making and implementation.

  10. Determination of Colistin and Colistimethate Levels in Human Plasma and Urine by High-Performance Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Bihan, Kevin; Lu, Qin; Enjalbert, Manon; Apparuit, Maxime; Langeron, Olivier; Rouby, Jean-Jacques; Funck-Brentano, Christian; Zahr, Noël

    2016-12-01

    Colistin is a polypeptide antibiotic from the polymyxin E group used for the treatment of infections caused by multidrug-resistant gram-negative bacteria. The main constituents, accounting for approximately 85% of this mixture, are colistin A (polymyxin E1) and colistin B (polymyxin E2). The aim of this study was to develop and validate new and fast methods of quantification of colistin A and B and its precursors [colistin methanesulfonate sodium (CMS) A and B] by ultraperformance liquid chromatography-tandem mass spectrometry in plasma and urine with short pretreatment and run times. Chromatography was performed on an Acquity UPLC-MS/MS system (WATERS) with a WATERS Acquity UPLC C18 column (4.6 × 150 mm, 3.5 μm particle size). The pretreatment of samples consists of precipitation and extraction into microcolumns plate and HLB 96-well plate 30 μm-30 mg (OASIS) with a Positive Pressure-96 (WATERS). Quantification was performed using a multiple reaction monitoring of the following transitions: m/z 390.9 → 385.1 for colistin A, m/z 386.2 → 101.0 for colistin B, and m/z 602.4 → 241.1 for polymyxin B1 sulfate. In plasma and urine, calibration curves were linear from 30 to 6000 ng/mL for colistin A and from 15 to 3000 ng/mL for colistin B. With an acceptable accuracy and precision, the lower limit of quantification were set at 24.0 ng/mL and 12.0 ng/mL for colistin A and B in plasma, and at 18.0 ng/mL and 9.0 ng/mL for colistin A and B in urine. These LC-MS/MS methods of quantification for colistin A and B and its precursors (CMS A and B) in plasma and urine are fast, simple, specific, sensitive, accurate, precise, and reliable. Furthermore, they are linear and repeatable. These procedures were successfully applied to a pharmacokinetic study of a critically ill patient suffering from ventilator-associated pneumonia, who was treated with nebulized CMS.

  11. The culture of Chlorella vulgaris with human urine in multibiological life support system experiments

    NASA Astrophysics Data System (ADS)

    Li, Ming; Liu, Hong; Tong, Ling; Fu, Yuming; He, Wenting; Hu, Enzhu; Hu, Dawei

    The Integrative Experimental System (IES) was established as a tool to evaluate the rela-tionship of the subsystems in Bioregenerative Life Support System, and Multibiological Life Support System Experiments (MLSSE) have been conducted in the IES. The IES consists of a higher plant chamber, an animal chamber and a plate photo bioreactor (PPB) which cultivated lettuce (Lactuca sativa L.), silkworm (Bombyx Mori L.) and microalgae (Chlorella vulgaris), respectively. In MLSSE, four volunteers took turns breathing the system air through a tube connected with the animal chamber periodically. According to the CO2 concentration in the IES, the automotive control system of the PPB changed the light intensity regulating the photosynthesis of Chlorella vulgaris to make CO2 /O2 in the system maintain at stable levels. Chlorella vulgaris grew with human urine by carrying certain amount of alga liquid out of the bioreactor every day with synthetic urine replenished into the system, and O2 was regenerated, at the same time human urine was purified. Results showed that this IES worked stably and Chlorella vulgaris grew well; The culture of Chlorella vulgaris could be used to keep the balance of CO2 and O2 , and the change of light intensity could control the gas composition in the IES; Microalgae culture could be used in emergency in the system, the culture of Chlorella vulgaris could recover to original state in 5 days; 15.6 ml of condensation water was obtained every day by the culture of Chlorella vulgaris; The removal efficiencies of N, P in human urine could reach to 98.2% and 99.5%.

  12. Microanalyzer for Biomonitoring of Lead (Pb) in Blood and Urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yantasee, Wassana; Timchalk, Chuck; Lin, Yuehe

    2007-01-01

    Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. The state-of-the-art ICP-MS instruments analyze metals in laboratories, resulting in lengthy turn around time, and are expensive. In response to the growing need for metal analyzer for on-site, real-time monitoring of trace metals in individuals, we developed a portable microanalyzer based on flow-injection/adsorptive stripping voltammetry and used it to analyze Pb in rat blood and urine. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with the suitablemore » sample pretreatment and the turbulent flowing of Pb contained blood and urine onto the glassy electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. There was no matrix effect on the voltammetric Pb signals even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration range relevant to Pb exposure levels in human (0-20 ppb in 10%-blood samples, 0-50 ppb in 50%-urine samples). The device had excellent sensitivity and reproducibility; Pb detection limits were 0.54 ppb and 0.42 ppb, and % RSDs were 4.9 and 2.4 in 50%-urine and 10%-blood samples, respectively. It offered a high throughput (3 min per sample) and had economical use of samples (60 ?L per measurement), making the collection of blood being less invasive especially to children, and had low reagent consumption (1 ?g of Hg per measurement), thus minimizing the health concerns of mercury use. Being miniaturized in size, the microanalyzer is portable and field-deployable. Thus, it has a great potential to be the next-generation analyzer for biomonitoring of toxic metals.« less

  13. Power of Orbitrap-based LC-high resolution-MS/MS for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MSn or GC-MS procedures.

    PubMed

    Michely, Julian A; Meyer, Markus R; Maurer, Hans H

    2018-01-01

    Reliable, sensitive, and comprehensive urine screening procedures by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS) with low or high resolution (HR) are of high importance for drug testing, adherence monitoring, or detection of toxic compounds. Besides conventional urine sampling, dried urine spots are of increasing interest. In the present study, the power of LC-HR-MS/MS was investigated for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MS n or GC-MS procedures. Authentic human urine samples (n = 103) were split in 4 parts. One aliquot was prepared by precipitation (UP), one by UP with conjugate cleavage (UglucP), one spot on filter paper cards and prepared by on-spot cleavage followed by liquid extraction (DUSglucE), and one worked-up by acid hydrolysis, liquid-liquid extraction, and acetylation for GC-MS analysis. The 3 series of LC-HR-MS/MS results were compared among themselves, to corresponding published LC-MS n data, and to screening results obtained by conventional GC-MS. The reference libraries used for the 3 techniques contained over 4500 spectra of parent compounds and their metabolites. The number of all detected hits (770 drug intakes) was set to 100%. The LC-HR-MS/MS approach detected 80% of the hits after UP, 89% after UglucP, and 77% after DUSglucE, which meant over one-third more hits in comparison to the corresponding published LC-MS n results with ≤49% detected hits. The GC-MS approach identified 56% of all detected hits. In conclusion, LC-HR-MS/MS provided the best screening results after conjugate cleavage and precipitation. Copyright © 2017 John Wiley & Sons, Ltd.

  14. An Overview of My Internship with the Ecological Program at John F. Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Owen, Samantha

    2010-01-01

    During my internship with Innovative Health Applications, I participated in numerous longterm research projects involving the study of various plant and animal life at the Kennedy Space Center (KSC). I observed the monitoring of nesting sea turtles. I learned about the transfer of egg clutches from the northern Gulf Coast in an effort to help the hatchlings avoid the oil spill in the Gulf of Mexico. I gained knowledge of tracking the movements of important sport fish and sharks in this area using a hydro-acoustic tag and receiver system. This effort included routinely taking water quality data at multiple sites around KSC. Alligator population and nesting assessments was another part of my internship. I observed the biologists take morphometric measurements, blood, urine and tissue samples from alligators found in KSC waterways. I assisted in taking photosynthesis and reflectance measurements on various scrub oaks and palmettos. I participated in Florida Scrub-Jay surveys in an effort to monitor their population trends and was involved in Southeastern beach mouse trapping and identification. I also assisted in seagrass surveys monitoring the health of the seagrass beds.

  15. A Sensing System for Simultaneous Detection of Urine and its Components Using Plastic Optical Fibers

    NASA Astrophysics Data System (ADS)

    Ejaz, Tahseen; Takemae, Tadashi; Egami, Chikara; Tsuboi, Naoyuki

    A sensing system using plastic optical fibers and reagent papers was developed for the detection of urine and abnormal level of its components simultaneously. Among several components of urine the detection of two main components namely, protein and glucose was confirmed experimentally. Three states of the papers namely dry and wet with and without change in color, were taken into consideration. These three states were divided by setting the lower and upper threshold voltages at 2.2 V and 5.5 V, respectively. This system is considered to be simple in construction, easy to operate and cost-efficient.

  16. Treating urine by Spirulina platensis

    NASA Astrophysics Data System (ADS)

    Yang, Chenliang; Liu, Hong; Li, Ming; Yu, Chengying; Yu, Gurevich

    In this paper Spirulina platensis with relatively high nutrition was cultivated to treat human urine. Batch culture showed that the consumption of N in human urine could reach to 99%, and the consumption of P was more than 99.9%, and 1.05 g biomass was obtained by treating 12.5 ml synthetic human urine; continuous culture showed that S. platensis could consume N, Cl, K and S in human urine effectively, and the consumption could reach to 99.9%, 75.0%, 83.7% and 96.0%, respectively, and the consumption of P was over 99.9%, which is very important to increase the closure and safety of the bioregenerative life support system (BLSS).

  17. Implications of Maple Syrup Urine Disease in Newborns.

    PubMed

    Harris-Haman, Pamela; Brown, Lenora; Massey, Susan; Ramamoorthy, Sivaranjani

    Maple syrup urine disease (MSUD) is an inherited metabolic disorder that affects the body's ability to metabolize amino acids. If left untreated, it places newborns at risk for life-threatening health problems, including episodes of illness called metabolic crisis. Newborn screening for MSUD should ideally be done within the first 24 to 48 hours after birth. With proper screening, along with genetic counseling, nutritional counseling, primary care follow-up, and ongoing monitoring, newborns with MSUD can typically go on to live healthful lives. Nurses play a key role in supporting families with a diagnosis of MSUD. © 2017 AWHONN, the Association of Women’s Health, Obstetric and Neonatal Nurses.

  18. Utility of the Paris System in Reporting Urine Cytology.

    PubMed

    Malviya, Kiran; Fernandes, Gwendolyn; Naik, Leena; Kothari, Kanchan; Agnihotri, Mona

    2017-01-01

    To find out the utility of The Paris System (TPS) in reporting urine cytology and to compare it with the reporting system currently used in our laboratory. This retrospective study was undertaken over a period of 1 year during which slides of all the urine specimens sent for cytological examination were retrieved from our laboratory filling system. They were blindly reviewed and reclassified according to TPS. Surgical follow-up was obtained from the uropathology services of our department. A total of 176 cases were meticulously reviewed. The mean age of the patients was 52 years, and 71% of cases presented with hematuria. Histopathological follow-up was available in 34 cases. Reporting by TPS detected 13.0% high-grade urothelial carcinoma (HGUC) and 5.1% atypical urothelial cells versus 7.3 and 11.9% by the current reporting system, respectively. The sensitivity and diagnostic accuracy for detecting HGUC of TPS were higher than those of our reporting system. TPS has increased the rate of detection of HGUC and reduced the rate of reporting "atypical" urothelial cells. TPS has also standardized the diagnostic criteria, thereby bringing uniformity and reproducibility into the system of reporting for urine cytology. © 2017 S. Karger AG, Basel.

  19. Cleaved Form of Osteopontin in Urine as a Clinical Marker of Lupus Nephritis

    PubMed Central

    Kitagori, Koji; Yoshifuji, Hajime; Oku, Takuma; Sasaki, Chiyomi; Miyata, Hitomi; Mori, Keita P.; Nakajima, Toshiki; Ohmura, Koichiro; Kawabata, Daisuke; Yukawa, Naoichiro; Imura, Yoshitaka; Murakami, Kosaku; Nakashima, Ran; Usui, Takashi; Fujii, Takao; Sakai, Kaoru; Yanagita, Motoko; Hirayama, Yoshitaka; Mimori, Tsuneyo

    2016-01-01

    We assessed the utility of two forms of osteopontin (OPN), OPN full and its cleaved form (OPN N-half), in plasma and urine as markers of disease activity in lupus nephritis (LN). Samples were collected from patients with systemic lupus erythematosus (SLE) (LN: N = 29, non-LN: N = 27), IgA nephropathy (IgAN) (N = 14), minimal change nephrotic syndrome (MCNS) (N = 5), diabetic nephropathy (DN) (N = 14) and healthy volunteers (HC) (N = 17). While there was no significant difference in urine OPN full concentration between groups, urine OPN N-half concentration was significantly higher in patients with LN than HC (p < 0.05). Moreover, urine OPN N-half was higher in LN patients with overt proteinuria (urine protein/creatinine ratio: P/C > 0.5) than LN patients with minimal proteinuria (P/C < 0.5, p < 0.0001), and also higher than in DN patients with overt proteinuria (P/C > 0.5, p < 0.01). Urine thrombin activity correlated with urine OPN N-half concentration (p < 0.0001), but not with urine OPN full concentration. These results suggest that urine OPN N-half concentration reflects renal inflammation. Thus, urine OPN N-half may be a novel disease activity marker for LN. PMID:27992535

  20. Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis

    NASA Astrophysics Data System (ADS)

    Liu, Ping; Qi, Chu-Bo; Zhu, Quan-Fei; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-02-01

    Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for non-targeted profiling of thiols from cancer samples. Compared to traditional full scan mode, the DPI method significantly improved identification selectivity and accuracy. 103 thiol candidates were discovered in all cancers and 6 thiols were identified by their standards. It is worth noting that pantetheine, for the first time, was identified in human urine. Secondly, the IL-LC-MRM-MS method was developed for relative quantification of thiols in cancers compared to healthy controls. All the MRM transitions of light and heavy labeled thiols were acquired from urines by using DPI method. Compared to DPI method, the sensitivity of MRM improved by 2.1-11.3 folds. In addition, the concentration of homocysteine, γ-glutamylcysteine and pantetheine enhanced more than two folds in cancer patients compared to healthy controls. Taken together, the method demonstrated to be a promising strategy for identification and comprehensive quantification of thiols in human urines.

  1. Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis

    PubMed Central

    Liu, Ping; Qi, Chu-Bo; Zhu, Quan-Fei; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-01-01

    Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for non-targeted profiling of thiols from cancer samples. Compared to traditional full scan mode, the DPI method significantly improved identification selectivity and accuracy. 103 thiol candidates were discovered in all cancers and 6 thiols were identified by their standards. It is worth noting that pantetheine, for the first time, was identified in human urine. Secondly, the IL-LC-MRM-MS method was developed for relative quantification of thiols in cancers compared to healthy controls. All the MRM transitions of light and heavy labeled thiols were acquired from urines by using DPI method. Compared to DPI method, the sensitivity of MRM improved by 2.1–11.3 folds. In addition, the concentration of homocysteine, γ-glutamylcysteine and pantetheine enhanced more than two folds in cancer patients compared to healthy controls. Taken together, the method demonstrated to be a promising strategy for identification and comprehensive quantification of thiols in human urines. PMID:26888486

  2. Quantification of Modified Tyrosines in Healthy and Diabetic Human Urine using Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Kato, Yoji; Dozaki, Natsuko; Nakamura, Toshiyuki; Kitamoto, Noritoshi; Yoshida, Akihiro; Naito, Michitaka; Kitamura, Masayasu; Osawa, Toshihiko

    2009-01-01

    The quantification of urinary oxidized tyrosines, dityrosine (DiY), nitrotyrosine (NY), bromotyrosine (BrY), and dibromotyrosine (DiBrY), was accomplished by quadruple liquid chromatography-tandem mass spectrometry (LC/MS/MS). The sample was partially purified by solid phase extraction, and was then applied to the LC/MS/MS using multiple-reaction monitoring (MRM) methods. The analysis for the DiY quantification was done first. The residual samples were further butylated with n-butanol/HCl, and the other modified tyrosines were then quantified with isotopic dilution methods. MRM peaks of the modified tyrosines (DiY, NY, BrY, and DiBrY) from human urine were measured and the elution times coincided with the authentic and isotopic standards. The amounts of modified tyrosines in healthy human urine (n = 23) were 8.8 +/- 0.6 (DiY), 1.4 +/- 0.4 (NY), 3.8 +/- 0.3 (BrY), and 0.7 +/- 0.1 (DiBrY) micromol/mol of creatinine, respectively. A comparison of the modified tyrosines with urinary 8-oxo-deoxyguanosine, pentosidine, and N(epsilon)-(hexanoyl)lysine was also performed. Almost all products, except for NY, showed good correlations with each other. The amounts of the modified tyrosines (NY, BrY, and DiBrY) in the diabetic urine were higher than those in the urine from healthy people.

  3. Correlation of the levels of glycosaminoglycans between urine and dried urine in filter paper samples and their stability over time under different storage temperatures.

    PubMed

    Breier, Ana Carolina; Cé, Jaqueline; Coelho, Janice Carneiro

    2014-06-10

    Mucopolysaccharidoses (MPSs) are a group of lysosomal storage diseases caused by the deficiency/absence of enzymes which catalyze the degradation of glycosaminoglycans (GAGs). The use of biological samples dried on filter paper has been increasing because it makes it easy to ship them to reference laboratories. Urinary GAGs are the main biomarkers of MPS and, thus, we studied the correlations of determinations to GAGs and creatinine, as well as compared the GAGs' profile on electrophoresis, between urine and dried urine in filter paper (DUFP) samples. We also assessed the GAG stability over time under different storage temperatures. We quantified the GAG concentration in both sample types and compared the results by Pearson correlation. The results were very similar, with r=0.97 for creatinine and with r=0.94 and r=0.98 for GAGs for controls and patients, respectively, with similar electrophoretic profiles. The GAG stability in DUFP was up to 30days at -20, 4, and 25°C and up to 21days at 37°C. Our proposal assessed urinary GAGs in DUFP and concluded that these samples can be used in the investigation of MPS, replacing urine samples in neonatal screening and monitoring of therapies, due to ease of transportation and storage. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. [Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Lech, Rodziewicz; Jolanta, MasŁOwiecka; Anna, Sadowska; Halina, Car

    2017-10-08

    Five thyreostats (TSs), namely tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil, were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) in positive electrospray ionization mode. Extraction and clean-up were achieved using a ChemElut cartridge with tert -butyl methyl ether, without a derivatization step. Separation was achieved on an Acquity UPLC SS T3 column. The mobile phase was acetonitrile and water containing 0.2% (v/v) formic acid. The mass spectrometer was operated in multiple reaction monitoring mode. Urine samples were spiked with TS solution at levels corresponding to 5, 10, 15, and 20 μg/L. The accuracy (internal standard corrected) ranged from 92% to 107%, with a repeatability precision (relative standard deviation, RSD) less than 15% for all five analytes. The RSDs within-laboratory reproducibility was less than 26%. The decision limits (CCα) and detection capabilities (CCβ) were obtained from a calibration curve and were in the ranges of 3.1-6.1 μg/L and 4.0-7.4 μg/L, respectively. The CCα and CCβ values were below the recommended concentration, which was set at 10 μg/L. The results show that the described method is suitable for the direct detection of TSs in bovine urine. This method can also be used to determine TSs in porcine urine.

  5. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems.

    PubMed

    Ximenes, Camila; Brandão, Eduardo; Oliveira, Paula; Rocha, Abraham; Rego, Tamisa; Medeiros, Rafael; Aguiar-Santos, Ana; Ferraz, João; Reis, Christian; Araujo, Paulo; Carvalho, Luiz; Melo, Fabio L

    2014-12-01

    The Global Program for the Elimination of Lymphatic Filariasis (GPELF) aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR)-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2) and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2), which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  6. Micro-flow injection system for the urinary protein assay.

    PubMed

    Nishihama, Syouhei; Imabayashi, Hisano; Matoba, Tomoko; Toya, Chika; Watanabe, Kosuke; Yoshizuka, Kazuharu

    2008-02-15

    A urinary protein assay has been investigated, employing a micro-flow injection analysis (muFIA) combined with an adsorptive separation of protein from analyte. The adsorptive separation part of protein in the artificial urine with ceramic hydroxyapatite is integrated on the muFIA chip, since the interference of other components coexisting in urine occurs in the conventional FIA system. The typical FI peak can be obtained following the adsorption-elution process of the protein prior to the detection, and the protein concentration in artificial urine can be quantitatively determined.

  7. Physiological assessment of deer populations by analysis of urine in snow

    USGS Publications Warehouse

    DelGiudice, G.D.; Mech, L.D.; Seal, U.S.

    1989-01-01

    We compared the nutritional status of free-ranging white-tailed deer (Odocoileus virginianus) in 3 natural yards and 1 yard where deer were supplementally fed from 1 January to 31 March 1985 in northeastern Minnesota. We monitored deer nutritonal status by sequential collection and chemical analysis of urine in snow (snow-urine) for urea nitrogen (U), sodium (Na), potassium (K), calcium (Ca), and phosphorus (P). Dilution of urine by snow was corrected by comparing these data as ratios to creatinine (C). All deer remained in an early phase of undernutrition; however, declining trends of U:C, Na:C, and K:C in 2 natural yards indicated increasingly inadequate nutrition as winter progressed. Unaltered values of these ratios and P.C in snow-urine collected from the third natural yard reflected stable levels of nutrient availability. Significant (P < 0.05) elevations of Na:C, K:C, and P:C in 2 natural yards with similar snow regimes suggested initiation of nutritional recovery in deer during late March. In contrast, deep snow in the third natural yard restricted feeding activity and was associated with ratios that remained diminished. Elevated U:C, Na:C, and K:C provided physiological evidence of the higher nutritional status of supplementally fed deer throughout winter and their ability to increase nutrient intake during late March despite prolonged deep snow cover. Frequent and quantitative assessments of the physiological status of deer by snow-urine analysis provided an improved understanding of the relationship between snow cover and the nutritional well-being of these deer.

  8. The ultimate veal calf reference experiment: hormone residue analysis data obtained by gas and liquid chromatography tandem mass spectrometry.

    PubMed

    Nielen, Michel W F; Lasaroms, Johan J P; Essers, Martien L; Sanders, Marieke B; Heskamp, Henri H; Bovee, Toine F H; van Rhijn, J Hans; Groot, Maria J

    2007-03-14

    A lifetime controlled reference experiment has been performed using 42 veal calves, 21 males and 21 females which were fed and housed according to European regulations and common veterinary practice. During the experiment feed, water, urine and hair were sampled and feed intake and growth were monitored. Thus for the first time residue analysis data were obtained from guaranteed lifetime-untreated animals. The analysis was focused on the natural hormones estradiol and testosterone and their metabolites, on 17beta- and 17alpha-nortestosterone, on 17beta- and 17alpha-boldenone and androsta-1,4-diene-3,17-dione (ADD), and carried out by gas chromatography tandem mass spectrometry (GC/MS/MS), an estrogen bioassay and liquid chromatography (LC) MS/MS. Feed, water and hair samples were negative for the residues tested. Female calf urines showed occasionally low levels of 17alpha-estradiol and 17alpha-testosterone. On one particular sampling day male veal calf urines showed very high levels of 17alpha-testosterone (up to 1000 ng mL(-1)), accompanied by lower levels of estrone and 17beta-testosterone. Despite these extreme levels of natural testosterone, 17beta-boldenone was never detected in the same urine samples; even 17alpha-boldenone and ADD were only occasionally beyond CCalpha (maximum levels 2.7 ng mL(-1)). The data from this unique experiment provide a set of reference values for steroid hormones in calf urine and demonstrate that 17beta-boldenone is not a naturally occurring compound in urine samples.

  9. Role of Urine Drug Testing in the Current Opioid Epidemic.

    PubMed

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  10. Impact of collection conditions on the metabolite content of human urine samples as analyzed by liquid chromatography coupled to mass spectrometry and nuclear magnetic resonance spectroscopy.

    PubMed

    Roux, Aurélie; Thévenot, Etienne A; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe

    There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at -80 °C. Samples were analyzed by high-performance liquid chromatography coupled to high-resolution mass spectrometry and bacterial contamination was monitored by turbidimetry. Multivariate analyses showed that urinary metabolic fingerprints were affected by the presence of preservatives and also by storage at room temperature from 24 to 72 h, whereas no change was observed for urine samples stored at 4 °C over a 72-h period. Investigations were then focused on 280 metabolites previously identified in urine: 19 of them were impacted by the kind of sample collection protocol in both experiments, including 12 metabolites affected by bacterial contamination and 7 exhibiting poor chemical stability. Finally, our results emphasize that the use of preservative prevents bacterial overgrowth, but does not avoid metabolite instability in solution, whereas storage at 4 °C inhibits bacterial overgrowth at least over a 72-h period and slows the chemical degradation process. Consequently, and for further LC/MS analyses, human urine samples should be kept at 4 °C if their collection is performed over 24 h.

  11. Evaluation of Dried Urine Spot Method to Screen Cotinine among Tobacco Dependents: An Exploratory Study.

    PubMed

    Jain, Raka; Quraishi, Rizwana; Verma, Arpita

    2017-01-01

    Assessment of cotinine, a metabolite of nicotine in body fluids, is an important approach for validating the self-report among tobacco users. Adaptation of assays on dried urine spots (DUSs) has advantages of ease of collection, transportation, minimal invasiveness, and requirement of small volume. The aim of the present study was to develop an efficient method for testing cotinine in DUSs and evaluating its clinical applicability. This involved optimization of conditions for detection, recovery, and stability of cotinine from dried urine, spotted on filter paper. Enzyme-linked immunosorbent assay was used for screening, whereas confirmation was done by gas chromatography. For clinical applicability, urine samples of tobacco users were tested. Water was found to be a suitable extracting solvent as compared to carbonate-bicarbonate buffer (pH 9.2) and saline. Screening was achieved by two punches taken from a 20 μl (diameter 1.3 cm) spotted urine samples, and confirmation was achieved by five complete circles each of 20 μl sample volume. The recovery was found to be 97% in water. Limit of detection for the method was found to be 100 ng/ml. No signs of significant degradation were found under all storage conditions. All the urine samples of tobacco users were found to be positive by a conventional method as well as DUSs, and the method proved to be efficient. DUS samples are a useful alternative for biological monitoring of recent nicotine use, especially in developing countries where sample logistics could be an important concern.

  12. Factors affecting variability in the urinary biomarker 1,6-hexamethylene diamine in workers exposed to 1,6-hexamethylene diisocyanate.

    PubMed

    Gaines, Linda G T; Fent, Kenneth W; Flack, Sheila L; Thomasen, Jennifer M; Whittaker, Stephen G; Nylander-French, Leena A

    2011-01-01

    Although urinary 1,6-hexamethylene diamine (HDA) is a useful biomarker of exposure to 1,6-hexamethylene diisocyanate (HDI), a large degree of unexplained intra- and inter-individual variability exists between estimated HDI exposure and urine HDA levels. We investigated the effect of individual and workplace factors on urine HDA levels using quantitative dermal and inhalation exposure data derived from a survey of automotive spray painters exposed to HDI. Painters' dermal and breathing-zone HDI-exposures were monitored over an entire workday for up to three separate workdays, spaced approximately one month apart. One urine sample was collected before the start of work with HDI-containing paints, and multiple samples were collected throughout the workday. Using mixed effects multiple linear regression modeling, coverall use resulted in significantly lower HDA levels (p = 0.12), and weekday contributed to significant variability in HDA levels (p = 0.056). We also investigated differences in urine HDA levels stratified by dichotomous and classification covariates using analysis of variance. Use of coveralls (p = 0.05), respirator type worn (p = 0.06), smoker status (p = 0.12), paint-booth type (p = 0.02), and more than one painter at the shop (p = 0.10) were all found to significantly affect urine HDA levels adjusted for creatinine concentration. Coverall use remained significant (p = 0.10), even after adjusting for respirator type. These results indicate that the variation in urine HDA level is mainly due to workplace factors and that appropriate dermal and inhalation protection is required to prevent HDI exposure.

  13. Optimization for Peptide Sample Preparation for Urine Peptidomics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigdel, Tara K.; Nicora, Carrie D.; Hsieh, Szu-Chuan

    2014-02-25

    Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides andmore » the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.« less

  14. Urine epidermal growth factor, monocyte chemoattractant protein-1 or their ratio as predictors of complete remission in primary glomerulonephritis.

    PubMed

    Chanrat, Eakkapat; Worawichawong, Supanat; Radinahamed, Piyanuch; Sathirapongsasuti, Nuankanya; Nongnuch, Arkom; Assanatham, Montira; Udomsubpayakul, Umaporn; Kitiyakara, Chagriya

    2018-04-01

    The balance of several cytokines likely influences the resolution of glomerulonephritis. Monocyte chemoattractant protein-1(MCP-1) is a chemokine that promotes renal inflammation whereas epidermal growth factor (EGF) stimulates protective responses. Previously, high urine MCP-1(MCP-1) and low urine EGF (EGF) levels were found to be associated with tubulointerstitial fibrosis, but there is limited information on the value of these mediators as predictors of therapeutic responses or long term outcome in primary glomerulonephritis. To determine the performance of urine EGF, MCP-1 or their ratio at baseline as biomarkers to predict complete remission, and the relationship of these mediators with subsequent renal function 24 months later in primary glomerulonephritis. This is a prospective study of patients with biopsy-proven primary glomerulonephritis. Baseline urine samples were collected at biopsy before therapy. MCP-1 and EGF were analyzed by enzyme-linked immunosorbent assays and expressed as a ratio to urine creatinine (ng/mgCr) or as EGF/MCP-1 ratio (ng/ng). Proteinuria and estimated glomerular filtration rate (eGRF) were monitored after therapy. Complete remission (CR) was defined as proteinuria ≤ 0.3 g/gCr. Median follow-up was 20 months. Of all patients (n = 74), 38 patients (51.4%) subsequently achieved CR. Baseline urine EGF and EGF/MCP-1 levels were significantly higher in CR compared to Not CR. By contrast, MCP-1 was not different. High EGF (EGF > 75 ng/mgCr) was a significant predictor (OR 2.28) for CR by multivariate analysis after adjusting for proteinuria, blood pressure, baseline eGFR. In patients who completed 24 months follow-up (n = 43), baseline EGF correlated inversely with proteinuria and positively with eGFR at 24 months. High urine EGF level is a promising biomarker of CR. Baseline EGF levels correlated with kidney function at 2 years. EGF/MCP-1 was not superior to EGF alone. Further studies are necessary to determine the role of urine EGF as a guide to therapy in primary GN. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Fertilizer from dried human urine added to ash and lime - a potential product from eco-sanitation system.

    PubMed

    Dutta, Shanta; Vinnerås, Björn

    2016-09-01

    This research explored the possibility of making fertilizer at a laboratory from source separated and untreated human urine added to ash and lime by drying at low temperatures. A mixture of ash and lime (1:1) was used as drying agent and human urine was applied as undiluted and fresh. Ash and lime were chosen as drying agents for maintaining a pH > 10 during the drying process, which should inhibit urea hydrolysis in urine, and thereby urea should be retained in the drying agent. The drying technique was developed and drying capacity of the system was quantified; three specific temperatures (20 °, 35 °, 60 °C) and two airflow rates (1 L/min and 5 L/min) were used in the experiment. A mass balance for nitrogen in the system was obtained. It was evident from the experiment that urea can be retained by maintaining a high pH (>10). Urine drying at 20 °C was not a feasible option, since rate of evaporation was very low. The highest retention of inflow nitrogen at 35 °C and 60 °C were 74% and 54%, respectively, in the produced fertilizer. Reduced evaporation rate, flooding of urine over drying agent, and blockage in airflow influenced nitrogen loss and concentration of nitrogen in the final product.

  16. Urine Pretreatment Configuration and Test Results for Space Applications

    NASA Technical Reports Server (NTRS)

    Howard, Stanley G.; Hutchens, Cindy F.; Rethke, Donald W.; Swartley, Vernon L.; Marsh, Robert W.

    1998-01-01

    Pretreatment of urine using Oxone and sulfuric acid is baselined in the International Space Station (ISS) waste water reclamation system to control odors, fix urea and control microbial growth. In addition, pretreatment is recommended for long term flight use of urine collection and two phase separation to reduce or eliminate fouling of the associated hardware and plumbing with urine precipitates. This is important for ISS application because the amount of maintenance time for cleaning and repairing hardware must be minimized. This paper describes the development of a chemical pretreatment system based on solid tablet shapes which are positioned in the urine collection hose and are dissolved by the intrained urine at the proper ratio of pretreatment to urine. Building upon the prior success of the developed and tested solid Oxone tablet a trade study was completed to confirm if a similar approach, or alternative, would be appropriate for the sulfuric acid injection method. In addition, a recommended handling and packaging approach of the solid tablets for long term, safe and convenient use on ISS was addressed. Consequently, the solid tablet concept with suitable packaging was identified as the Urine Pretreat / Prefilter Assembly (UPPA). Testing of the UPPA configuration confirmed the disolution rates and ratios required by ISS were achieved. This testing included laboratory controlled methods as well as a 'real world' test evaluation that occurred during the 150 day Stage 10 Water Recovery Test (WRT) conducted at NASA Marshall Space Flight Center (MSFC).

  17. Validation and Application of a Simple UHPLC–MS-MS Method for the Enantiospecific Determination of Warfarin in Human Urine

    PubMed Central

    Alshogran, Osama Y.; Ocque, Andrew J.; Leblond, François A.; Pichette, Vincent; Nolin, Thomas D.

    2016-01-01

    A simple and rapid liquid chromatographic–tandem mass spectrometric method has been developed and validated for the enantiospecific determination of R- and S-warfarin in human urine. Warfarin enantiomers were extracted from urine using methyl tert-butyl ether. Chromatographic separation of warfarin enantiomers and the internal standard d5-warfarin was achieved using a Astec Chirobiotic V column with gradient mobile phase at a flow rate of 400 µL/min over 10 min. Detection was performed on a TSQ Quantum Ultra triple quadrupole mass spectrometer equipped with a heated electrospray ionization source. Analytes were detected in negative ionization mode using selected reaction monitoring. Calibration curves were linear with a correlation coefficient of ≥0.996 for both enantiomers over a concentration range of 5–500 ng/mL. The intra- and interday accuracy and precision for both analytes were within ±9.0%. Excellent extraction efficiency and negligible matrix effects were observed. The applicability of the method was demonstrated by successful measurement of warfarin enantiomers in urine of patients with kidney disease. The method is simple, accurate and reproducible and is currently being used to support warfarin pharmacokinetic studies. PMID:26657732

  18. Development of urine standard reference materials for metabolites of organic chemicals including polycyclic aromatic hydrocarbons, phthalates, phenols, parabens, and volatile organic compounds.

    PubMed

    Schantz, Michele M; Benner, Bruce A; Heckert, N Alan; Sander, Lane C; Sharpless, Katherine E; Vander Pol, Stacy S; Vasquez, Y; Villegas, M; Wise, Stephen A; Alwis, K Udeni; Blount, Benjamin C; Calafat, Antonia M; Li, Zheng; Silva, Manori J; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G; Sjödin, Andreas

    2015-04-01

    Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers' Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants.

  19. Development of urine standard reference materials for metabolites of organic chemicals including polycyclic aromatic hydrocarbons, phthalates, phenols, parabens, and volatile organic compounds

    PubMed Central

    Schantz, Michele M.; Benner, Bruce A.; Heckert, N. Alan; Sander, Lane C.; Sharpless, Katherine E.; Vander Pol, Stacy S.; Vasquez, Y.; Villegas, M.; Wise, Stephen A.; Alwis, K. Udeni; Blount, Benjamin C.; Calafat, Antonia M.; Li, Zheng; Silva, Manori J.; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G.; Sjödin, Andreas

    2016-01-01

    Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers’ Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers’ Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants. PMID:25651899

  20. Detection time for THC in oral fluid after frequent cannabis smoking.

    PubMed

    Andås, Hilde T; Krabseth, Hege-Merete; Enger, Asle; Marcussen, Bjarne N; Haneborg, An-Magritt; Christophersen, Asbjørg S; Vindenes, Vigdis; Øiestad, Elisabeth L

    2014-12-01

    The use of oral fluid for detecting drugs of abuse has become increasingly more frequent. Few studies have, however, investigated the detection times for drugs of abuse in oral fluid, compared with that of in urine or in blood. Cannabis is the world's most widely used drug of abuse, and the detection times for cannabis, in different types of matrixes, are therefore important information to the laboratories or institutions performing and evaluating drugs of abuse analyses. It is well known that frequent use of high dosages of cannabis, for longer periods of time, might lead to prolonged detection times for THC-COOH in urine. Cannabis intake is detected in oral fluid as THC, and a positive finding is considered to be a result of recent smoking, although some studies have already reported longer detection times. The aim of this study was to investigate the detection time for THC in oral fluid, collected from drug addicts admitted for detoxification. Findings in oral fluid were compared with findings in urine, among 26 patients admitted to a closed detoxification unit. The study, being the first in doing so, describes the concentration-time profiles for THC in oral fluid among chronic cannabis users, during monitored abstinence, using the Intercept collection kit. The study also includes the concentration-time profiles for creatinine-corrected THC-COOH ratios in urine samples, included to monitor for the possibility of new intakes. THC was detected in oral fluid collected from 11 of the 26 patients in the study. The elimination curves for THC in oral fluid revealed that negative samples could be interspersed among positive samples several days after cessation, whereas the THC-COOH concentrations in urine were decreasing. THC was, in this study, detected in oral fluid for up to 8 days after admission. The study shows that frequent use of high dosages of cannabis may lead to prolonged detection times, and that positive samples can be interspersed among negative samples. These results are of great importance when THC results from oral fluid analyses are to be interpreted.

  1. Determination of piperphentonamine and metabolites M1 and M6 in human plasma and urine by LC/MS/MS and its application in a pharmacokinetics study in Chinese healthy volunteers.

    PubMed

    Shi, Aixin; Hu, Xin; Li, Kexin; Li, Jian; Han, Liping; Wan, Huayin; Li, Rubing

    2012-11-01

    Piperphentonamine hydrochloride (PPTA) is a new calcium sensitizer. A liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for determination of piperphentonamine and its metabolites M1 and M6 was developed for the first time and applied to a pharmacokinetics study. Protein precipitation was used for pre-treatment of plasma samples, and solid phase extraction method was used for pre-treatment of urine samples. The chromatographic separation was achieved on a C(18) column using gradient elution in this study: A: 1% acetic acid aqueous solution, and B: acetonitrile. The whole analysis lasted for 10.5min and the gradient flow rate was 0.25mL/min constantly. The detection was performed of a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via a positive electrospray ionization source. The results were that the m/z ratios of monitored precursor ions and product ions of PPTA, M1 and M6 were 354.0→191.8, 356.0→148.7 and 358.0→148.7, respectively. From the standard curve, the concentration ranges of both PPTA and M1 in blood and urine samples were 0.1-500ng/mL and 0.1-200ng/mL, respectively; the concentration ranges of M6 in blood sample and urine sample were 0.2-500ng/mL and 0.2-200ng/mL, respectively; and the correlation coefficient of standard curve was r>0.99. A total of 31 healthy Chinese subjects participated in the pharmacokinetic study of single bolus intravenous injection of piperphentonamine hydrochloride. They were divided into three dosage groups and given 0.2, 0.4 and 0.6mg/kg of PPTA. After drug administration, concentrations of PPTA, M1 and M6 in human plasma and urine samples were determined to evaluation the pharmacokinetic characteristics of PPTA and its metabolites M1 and M6. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Occupational exposure to diisocyanates in polyurethane foam factory workers.

    PubMed

    Świerczyńska-Machura, Dominika; Brzeźnicki, Sławomir; Nowakowska-Świrta, Ewa; Walusiak-Skorupa, Jolanta; Wittczak, Tomasz; Dudek, Wojciech; Bonczarowska, Marzena; Wesolowski, Wiktor; Czerczak, Sławomir; Pałczyński, Cezary

    2015-01-01

    The aim of the study was to evaluate health effects of occupational exposure to diisocyanates (DIC) among polyurethane foam products factory workers. Thirty workers had a physical examination, skin prick tests with common allergens, allergen-specific immunoglobulin E (IgE) antibodies to diisocyanates and pulmonary function tests. Concentrations of selected isocyanates in the workplace air samples as well as concentration of their metabolites in the urine samples collected from the workers of the plant were determined. The most frequent work-related symptoms reported by the examined subjects were rhinitis and skin symptoms. Sensitization to at least 1 common allergen was noted in 26.7% of the subjects. Spirometry changes of bronchial obstruction of a mild degree was observed in 5 workers. The specific IgE antibodies to toluene diisocyanate (TDI) and 4,4'-methylenebis(phenyl isocyanate) (MDI) were not detected in any of the patients' serum. Cellular profiles of the collected induced sputum (ISP) did not reveal any abnormalities. Air concentrations of TDI isomers ranged 0.2-58.9 μg/m3 and in 7 cases they exceeded the Combined Exposure Index (CEI) value for those compounds. Concentrations of TDI metabolites in post-shift urine samples were significantly higher than in the case of pre-shift urine samples and in 6 cases they exceeded the British Biological Monitoring Guidance Value (BMGV - 1 μmol amine/mol creatinine). We didn't find a correlation between urinary concentrations of TDI, concentrations in the air and concentrations of toluenediamine (TDA) in the post shift urine samples. Lack of such a correlation may be an effect of the respiratory protective equipment use. Determination of specific IgE in serum is not sensitive enough to serve as a biomarker. Estimation of concentrations of diisocyanate metabolites in urine samples and the presence of work-related allergic symptoms seem to be an adequate method for occupational exposure monitoring of DIC, which may help to determine workers at risk as well as to recognize hazardous workplaces. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  3. Bilirubin - urine

    MedlinePlus

    ... Direct bilirubin - urine Images Male urinary system References Berk PD, Korenblat KM. Approach to the patient with ... Review Date 5/21/2017 Updated by: Laura J. Martin, MD, MPH, ABIM Board Certified in Internal ...

  4. A high-throughput robotic sample preparation system and HPLC-MS/MS for measuring urinary anatabine, anabasine, nicotine and major nicotine metabolites.

    PubMed

    Wei, Binnian; Feng, June; Rehmani, Imran J; Miller, Sharyn; McGuffey, James E; Blount, Benjamin C; Wang, Lanqing

    2014-09-25

    Most sample preparation methods characteristically involve intensive and repetitive labor, which is inefficient when preparing large numbers of samples from population-scale studies. This study presents a robotic system designed to meet the sampling requirements for large population-scale studies. Using this robotic system, we developed and validated a method to simultaneously measure urinary anatabine, anabasine, nicotine and seven major nicotine metabolites: 4-Hydroxy-4-(3-pyridyl)butanoic acid, cotinine-N-oxide, nicotine-N-oxide, trans-3'-hydroxycotinine, norcotinine, cotinine and nornicotine. We analyzed robotically prepared samples using high-performance liquid chromatography (HPLC) coupled with triple quadrupole mass spectrometry in positive electrospray ionization mode using scheduled multiple reaction monitoring (sMRM) with a total runtime of 8.5 min. The optimized procedure was able to deliver linear analyte responses over a broad range of concentrations. Responses of urine-based calibrators delivered coefficients of determination (R(2)) of >0.995. Sample preparation recovery was generally higher than 80%. The robotic system was able to prepare four 96-well plate (384 urine samples) per day, and the overall method afforded an accuracy range of 92-115%, and an imprecision of <15.0% on average. The validation results demonstrate that the method is accurate, precise, sensitive, robust, and most significantly labor-saving for sample preparation, making it efficient and practical for routine measurements in large population-scale studies such as the National Health and Nutrition Examination Survey (NHANES) and the Population Assessment of Tobacco and Health (PATH) study. Published by Elsevier B.V.

  5. Application of duckweed for human urine treatment in Bioregenerative Life Support System

    NASA Astrophysics Data System (ADS)

    Manukovsky, Nickolay; Kovalev, Vladimir

    The object of the study was the common duckweed Lemna minor L. Thanks to the ability to assimilate mineral and organic substances, duckweed is used to purify water in sewage lagoons. In addition, duckweed biomass is known to be a potential high-protein feed resource for domestic animals and fish. The aim of the study was to estimate an application of duckweed in a two-stage treatment of human urine in Bioregenerative Life Support System (BLSS). At the first stage, the urine’s organic matter is oxidized by hydrogen peroxide. Diluted solution of oxidized urine is used for cultivation of duckweed. The appointment of duckweed is the assimilation of mineralized substances of urine. Part of the duckweed biomass yield directly or after composting could be embedded in the soil-like substrate as organic fertilizer to compensate the carry-over in consequence of plant growing. The rest duckweed biomass could be used as a feed for animals in BLSS. Then, the residual culture liquid is concentrated and used as a source of dietary salt. It takes 10-15 m2 of duckweed culture per crewmember to treat oxidized urine. The BLSS configuration including two-component subsystem of urine treatment is presented.

  6. Challenges for environmental epidemiology research: are biomarker concentrations altered by kidney function or urine concentration adjustment?

    EPA Science Inventory

    Biological monitoring has become a standard approach to exposure assessment in occupational and environmental epidemiology. The use of biological effect markers to identify early adverse changes in target organs has also become widely adopted. Recently, nephrotoxicant research us...

  7. KINETIC MODEL OF FLUORIDE METABOLISM IN THE RABBIT

    EPA Science Inventory

    Sodium fluoride, in small doses, was given to rabbits intravenously or by stomach tube, and the appearance of fluoride in the blood and urine was then monitored frequently over the next 10 hours. Compartmental analysis of the data yielded a kinetic model of fluoride metabolism co...

  8. Enantioselective column coupled electrophoresis employing large bore capillaries hyphenated with tandem mass spectrometry for ultra-trace determination of chiral compounds in complex real samples.

    PubMed

    Piešťanský, Juraj; Maráková, Katarína; Kovaľ, Marián; Havránek, Emil; Mikuš, Peter

    2015-12-01

    A new multidimensional analytical approach for the ultra-trace determination of target chiral compounds in unpretreated complex real samples was developed in this work. The proposed analytical system provided high orthogonality due to on-line combination of three different methods (separation mechanisms), i.e. (1) isotachophoresis (ITP), (2) chiral capillary zone electrophoresis (chiral CZE), and (3) triple quadrupole mass spectrometry (QqQ MS). The ITP step, performed in a large bore capillary (800 μm), was utilized for the effective sample pretreatment (preconcentration and matrix clean-up) in a large injection volume (1-10 μL) enabling to obtain as low as ca. 80 pg/mL limits of detection for the target enantiomers in urine matrices. In the chiral CZE step, the different chiral selectors (neutral, ionizable, and permanently charged cyclodextrins) and buffer systems were tested in terms of enantioselectivity and influence on the MS detection response. The performance parameters of the optimized ITP - chiral CZE-QqQ MS method were evaluated according to the FDA guidance for bioanalytical method validation. Successful validation and application (enantioselective monitoring of renally eliminated pheniramine and its metabolite in human urine) highlighted great potential of this chiral approach in advanced enantioselective biomedical applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. 21 CFR 862.1665 - Sodium test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment... excretion of large amounts of dilute urine, accompanied by extreme thirst), adrenal hypertension, Addison's...

  10. 21 CFR 862.1375 - Histidine test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... free histidine (an amino acid) in plasma and urine. Histidine measurements are used in the diagnosis and treatment of hereditary histidinemia characterized by excess histidine in the blood and urine...

  11. 21 CFR 862.1665 - Sodium test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment... excretion of large amounts of dilute urine, accompanied by extreme thirst), adrenal hypertension, Addison's...

  12. 21 CFR 862.1375 - Histidine test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... free histidine (an amino acid) in plasma and urine. Histidine measurements are used in the diagnosis and treatment of hereditary histidinemia characterized by excess histidine in the blood and urine...

  13. 21 CFR 862.1285 - Etiocholanolone test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... intended to measure etiocholanolone in serum and urine. Etiocholanolone is a metabolic product of the hormone testosterone and is excreted in the urine. Etiocholanolone measurements are used in the diagnosis...

  14. Glomerulonephritis (For Parents)

    MedlinePlus

    ... a doctor right away to find the cause. Diagnosis At the doctor's office, explain your child's symptoms. ... Phosphorus Blood in the Urine (Hematuria) Living With Lupus Urine Tests Chronic Kidney Diseases Your Urinary System ...

  15. ED pharmacist monitoring of provider antibiotic selection aids appropriate treatment for outpatient UTI.

    PubMed

    Lingenfelter, Erin; Drapkin, Zachary; Fritz, Kelly; Youngquist, Scott; Madsen, Troy; Fix, Megan

    2016-08-01

    We sought to determine whether an emergency department (ED) pharmacist could aid in the monitoring and correction of inappropriate empiric antibiotic selection for urinary tract infections in an outpatient ED population. Urine cultures with greater than 100 000 CFU/mL bacteria from the University of Utah Emergency Department over 1 year (October 2011-Sept 2012) were identified using our electronic medical record system. Per ED protocol, an ED pharmacist reviews all cultures and performs a chart review of patient symptoms, diagnosis, and discharge antibiotics to determine whether the treatment was appropriate. A retrospective review of this process was performed to identify how often inappropriate treatment was recognized and intervened on by an ED pharmacist. Of the 180 cultures included, a total of 42 (23%) of empiric discharge treatments were considered inappropriate and required intervention. In 35 (83%) of 42 patients, the ED pharmacist was able to contact the patient and make appropriate changes; the remaining 7 patients were unable to be contacted, and no change could be made in their treatment. A chart review of all urine cultures with greater than 100 000 CFU/mL performed by an ED pharmacist helped identify inappropriate treatment in 23% of patients discharged to home with the diagnosis of urinary tract infection. Of these patients who had received inappropriate treatment, an ED pharmacist was able to intervene in 83% of cases. These data highlight the role of ED pharmacists in improving patient care after discharge. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. [The role of telomerase activity in non-invasive diagnostics of bladder cancer].

    PubMed

    Glybochko, P V; Alyaev, J G; Potoldykova, N V; Polyakovsky, K A; Vinarov, A Z; Glukhov, A I; Gordeev, S A

    2016-08-01

    To evaluate the potentials of determining the telomerase activity (TA) in the cellular material of the urine for noninvasive diagnosis of bladder cancer (BC). Evaluation of TA was performed in the urine of 48 patients with bladder cancer (study group) before and after transurethral resection of the bladder wall (n=38), an open resection of the bladder (n=4), and cystectomy (n=6). TA was also evaluated in 48 tumor tissue samples obtained from these patients during removal of the bladder tumor. Each sample of the tumor tissue was separated into two parts, one of which was subjected to histological examination, and the latter was used to determine the telomerase activity. In all cases, the diagnosis of bladder cancer was confirmed morphologically. Determination of TA in the samples was performed by the modified TRAP-method (telomerase repeat amplification protocol), RT-PCR, PCR, and electrophoresis. As a control, cell material of the urine and tissue in 12 patients with chronic cystitis was investigated. TA before surgery was found in 45 (93.75%) of 48 samples of cellular material of the urine from patients with suspected bladder cancer. BC was histologically verified in all patients in this group. In the postoperative period, TA was not observed in the 48 samples of cellular material of the urine from patients with BC. In the control group of patients with histologically verified cystitis, weak TA was determined only in one sample of cellular material of the urine. The analysis indicates statistically significant predominance of patients with bladder cancer in case of TA in the urine (P=0.001). TA was detected in all samples of tumor tissue. We also analyzed the dependence of TA levels in urine and tissue on the degree of BC differentiation. In patients with highly differentiated BC, mean AT in the cellular materials of the urine was 0,61% (n=15), in patients with moderately differentiated BC - 0.95% (n=23), in patients with low-grade bladder cancer - 1.33% (n=10); in other words, increase in the TA levels with decreasing the degree of differentiation was observed. This finding can be used in the prognosis of the course of disease based on determining the TA level in these patients. Preliminary data indicate the possibility of use of determining the TA in cellular material of the urine for the diagnosis and monitoring of bladder cancer recurrence.

  17. Development and evaluation of an enzyme-linked immunosorbent assay (ELISA) method for the measurement of 2,4-dichlorophenoxyacetic acid in human urine.

    PubMed

    Chuang, Jane C; Emon, Jeanette M Van; Durnford, Joyce; Thomas, Kent

    2005-09-15

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within +/-20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within +/-20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30ng/mL by ELISA and 0.2ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10mL of urine converted into 1mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.

  18. Urine Multi-drug Screening with GC-MS or LC-MS-MS Using SALLE-hybrid PPT/SPE.

    PubMed

    Lee, Junhui; Park, Jiwon; Go, Ahra; Moon, Heesung; Kim, Sujin; Jung, Sohee; Jeong, Wonjoon; Chung, Heesun

    2018-05-14

    To intoxicated patients in the emergency room, toxicological analysis can be considerably helpful for identifying the involved toxicants. In order to develop a urine multi-drug screening (UmDS) method, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) were used to determine targeted and unknown toxicants in urine. A GC-MS method in scan mode was validated for selectivity, limit of detection (LOD) and recovery. An LC-MS-MS multiple reaction monitoring (MRM) method was validated for lower LOD, recovery and matrix effect. The results of the screening analysis were compared with patient medical records to check the reliability of the screen. Urine samples collected from an emergency room were extracted through a combination of salting-out assisted liquid-liquid extraction (SALLE) and hybrid protein precipitation/solid phase extraction (hybrid PPT/SPE) plates and examined by GC-MS and LC-MS-MS. GC-MS analysis was performed as unknown drug screen and LC-MS-MS analysis was conducted as targeted drug screen. After analysis by GC-MS, a library search was conducted using an in-house library established with the automated mass spectral deconvolution and identification system (AMDISTM). LC-MS-MS used Cliquid®2.0 software for data processing and acquisition in MRM mode. An UmDS method by GC-MS and LC-MS-MS was developed by using a SALLE-hybrid PPT/SPE and in-house library. The results of UmDS by GC-MS and LC-MS-MS showed that toxicants could be identified from 185 emergency room patient samples containing unknown toxicants. Zolpidem, acetaminophen and citalopram were the most frequently encountered drugs in emergency room patients. The UmDS analysis developed in this study can be used effectively to detect toxic substances in a short time. Hence, it could be utilized in clinical and forensic toxicology practices.

  19. Comparison of the Automated cobas u 701 Urine Microscopy and UF-1000i Flow Cytometry Systems and Manual Microscopy in the Examination of Urine Sediments.

    PubMed

    Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee

    2016-09-01

    The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.

  20. Low-power wireless micromanometer system for acute and chronic bladder-pressure monitoring.

    PubMed

    Majerus, Steve J A; Fletter, Paul C; Damaser, Margot S; Garverick, Steven L

    2011-03-01

    This letter describes the design, fabrication, and testing of a wireless bladder-pressure-sensing system for chronic, point-of-care applications, such as urodynamics or closed-loop neuromodulation. The system consists of a miniature implantable device and an external RF receiver and wireless battery charger. The implant is small enough to be cystoscopically implanted within the bladder wall, where it is securely held and shielded from the urine stream. The implant consists of a custom application-specific integrated circuit (ASIC), a pressure transducer, a rechargeable battery, and wireless telemetry and recharging antennas. The ASIC includes instrumentation, wireless transmission, and power-management circuitry, and on an average draws less than 9 μA from the 3.6-V battery. The battery charge can be wirelessly replenished with daily 6-h recharge periods that can occur during the periods of sleep. Acute in vivo evaluation of the pressure-sensing system in canine models has demonstrated that the system can accurately capture lumen pressure from a submucosal implant location.

  1. Assessing U.S. sodium intake through dietary data and urine biomarkers

    USDA-ARS?s Scientific Manuscript database

    Sodium intake is directly related to blood pressure, a primary risk factor for heart disease and stroke. Reducing intake is estimated to save billions in U.S. health care dollars annually. Current public health recommendations and efforts targeting sodium reductions make accurate monitoring of pop...

  2. AN ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) METHOD FOR MONITORING 2,4 DICHLOROPHENOXYACETIC ACID (2,4-D) EXPOSURES

    EPA Science Inventory

    Abstract describes a streamlined ELISA method developed to quantitatively measure 2,4-D in human urine samples. Method development steps and comparison with gas chromatography/mass spectrometry are presented. Results indicated that the ELISA method could be used as a high throu...

  3. Nutritional Status Assessment (SMO 016E)

    NASA Technical Reports Server (NTRS)

    Smith, S. M.; Zwart, S. R.; Heer, M.; Coburn, S. P.; Booth, S. A.; Jones, J. A.; Lupton, J.

    2007-01-01

    It has not been possible to assess nutritional status of crew members on the ISS during flight because blood and urine could not be collected during ISS missions. Postflight observations of alterations in nutritional status for several nutrients are troubling, and we require the ability to monitor the status of these nutrients during flight to determine if there is a specific impetus or timeframe for these changes. In addition to the monitoring of crew nutritional status during flight, in-flight sample collection would allow better assessment of countermeasure effectiveness. SMO 016E is also designed to expand the current medical requirement for nutritional assessment (MR016L) to include additional normative markers for assessing crew health and countermeasure effectiveness. Additional markers of bone metabolism will be measured to better monitor bone health and the effectiveness of countermeasures to prevent bone resorption. New markers of oxidative damage will be measured to better assess the type of oxidative insults that occur during space flight. The array of nutritional assessment parameters will be expanded to include parameters that will allow us to better understand changes in folate and vitamin B6 status, and related cardiovascular risk factors during and after flight. Additionally, stress hormones and hormones that affect bone and muscle metabolism will also be measured. This additional assessment will allow us to better monitor the health of crew members and make more accurate recommendations for their rehabilitation. Several nutritional assessment parameters are altered at landing, but it is not known how long these changes persist. We extended the current protocol to include an additional postflight blood and urine sample collection 30 days after landing. Data are being collected before, during, and after flight. These data will provide a complete survey of how nutritional status and related systems are affected by space flight. Analyzing the data will help us to define nutritional requirements for long-duration missions. This expanded set of measurements will also aid in the identification of nutritional countermeasures to counteract, for example, the deleterious effects of microgravity on bone and muscle and the effects of space radiation.

  4. Nutritional Status Assessment (SMO 016E)

    NASA Technical Reports Server (NTRS)

    Smith, S. M.; Zwart, S. R.; Heer, M.; Ericson, K.; Coburn, S. P.; Booth, S. A.; Jones, J. A.; Lupton, J.

    2009-01-01

    Until 2006, it was not been possible to assess nutritional status of crewmembers on the ISS during flight because blood and urine could not be collected during ISS missions. Postflight observations of alterations in status of several nutrients are troubling, and we require the ability to monitor the status of these nutrients during flight to determine if there is a specific impetus or timeframe for these changes. In addition to the monitoring of crew nutritional status during flight, in-flight sample collection would allow better assessment of countermeasure effectiveness. Collecting samples during flight is one of the objectives of SMO 016E, and it is also designed to expand the current medical requirement for nutritional assessment (MR016L) to include additional normative markers for assessing crew health and countermeasure effectiveness. Additional markers of bone metabolism will be measured to better monitor bone health and the effectiveness of countermeasures to prevent bone resorption. New markers of oxidative damage will be measured to better assess the type of oxidative insults that occur during space flight. The array of nutritional assessment variables will be expanded to include ones that will allow us to better understand changes in folate, vitamin K, and vitamin B6 status, as well as risk factors for cardiovascular and oxidative damage during and after flight. Stress hormones and hormones that affect bone and muscle metabolism will also be measured. Measuring these additional variables will allow us to better monitor the health of crewmembers and make more accurate recommendations for their rehabilitation. Several nutritional assessment variables are altered at landing, but it is not known how long these changes persist. We extended the original protocol to include an additional postflight blood and urine sample collection 30 days after landing. Data are being collected before, during, and after flight. These data will provide a complete survey of how nutritional status and related systems are affected by space flight. Analyzing the data will help us to define nutritional requirements for long-duration missions. This expanded set of measurements will also aid in the identification of nutritional countermeasures to counteract, for example, the deleterious effects of microgravity on bone and muscle and the effects of space radiation.

  5. Persons with Mild or Moderate Alzheimer's Disease Learn to Use Urine Alarms and Prompts to Avoid Large Urinary Accidents

    ERIC Educational Resources Information Center

    Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Bosco, Andrea; Zonno, Nadia; Badagliacca, Francesco

    2011-01-01

    This study assessed whether three patients with Alzheimer's disease could learn to use urine alarms and caregivers' prompts to eliminate large urinary accidents. As soon as the patient began to release urine, the alarm system presented auditory and vibratory signals. In relation to those signals, the caregiver would prompt/encourage the patient to…

  6. Regulated bioanalysis of conformers - A case study with ASP2151 in dog plasma and urine.

    PubMed

    Ohtsu, Yoshiaki; Otsuka, Shohei; Nakamura, Takeshi; Noguchi, Kiyoshi

    2015-08-01

    We developed and validated bioanalytical methods for a potent helicase-primase inhibitor ASP2151 that has two conformers. These conformers elute as unseparated broad peaks under ordinary high-performance liquid chromatographic conditions, indicating discernable differences in hydrophobicity. We observed that column temperature and mobile phase pH have no effect on these peaks and that conformers form a single symmetrical peak when tetrahydrofuran is added to the mobile phase. In addition, we needed to develop semi-automated methods where inter-conversion of the conformers is unlikely to cause sample-to-sample extraction variability. Briefly, following the addition of deuterium-labeled ASP2151 as an internal standard (IS), dog plasma samples or acetonitrile-added urine samples were filtrated. The filtrates were then injected into a column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) system and trapped onto an extraction column. Extracts were back-flushed onto an analytical C18 column (4.6×50mm, 3μm) with a mobile phase consisting of methanol, tetrahydrofuran, and 20mmol/L ammonium acetate (45:5:50, v/v/v). The eluent was monitored in the negative atmospheric pressure chemical ionization mode. The calibration curve was linear over a range of 5-1000ng/mL for plasma and 0.5-100μg/mL for urine. Validation data met the acceptance criteria in accordance with regulatory guidance and demonstrated that these methods were selective, accurate, and reproducible. In addition, the present methods were successfully applied to a pharmacokinetic study in dogs. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Simultaneous quantitative and qualitative analysis of aliskiren, enalapril and its active metabolite enalaprilat in undiluted human urine utilizing LC-ESI-MS/MS.

    PubMed

    Burckhardt, Bjoern B; Tins, Jutta; Laeer, Stephanie

    2014-12-01

    The benefit-risk ratio of combined blocking by the direct renin inhibitor aliskiren and an angiotensin-converting enzyme inhibitor (e.g. enalapril) on the renin-angiotensin-aldosterone system is discussed. No method was available for simultaneous determination of both drugs in urine. A novel sensitive method for simultaneous quantification in undiluted human urine was developed which enables systematic pharmacokinetic investigations, especially in poorly investigated populations like children. Matrix effects were clearly reduced by applying solid-phase extraction followed by a chromatographic separation on Xselect(TM) C18 CSH columns. Mobile phase consisted of methanol and water, both acidified with formic acid. Under gradient conditions and a flow rate of 0.4 mL/min the column effluent was monitored by tandem mass spectrometry with electrospray ionization. Calibration curves were constructed in the range of 9.4-9600 ng/mL regarding aliskiren, 11.6-12000 ng/mL for enalapril and 8.8-9000 ng/mL for enalaprilat. All curves were analyzed utilizing 1/x(2) -weighted quadratic squared regression. Intra-run and inter-run precision were 3.2-5.8% and 6.1-10.3% for aliskiren, 2.4-6.1% and 3.9-7.9% for enalapril as well as 3.1-9.4% and 4.7-12.7% regarding enalaprilat. Selectivity, accuracy and stability results comply with current international bioanalysis guidelines. The fully validated method was successfully applied to a pharmacokinetic investigation in healthy volunteers. Copyright © 2014 John Wiley & Sons, Ltd.

  8. Highly sensitive and selective analysis of urinary steroids by comprehensive two-dimensional gas chromatography combined with positive chemical ionization quadrupole mass spectrometry

    PubMed Central

    Zhang, Ying; Tobias, Herbert J.; Brenna, J. Thomas

    2014-01-01

    Comprehensive two dimensional gas chromatography (GC×GC) provides greater separation space than conventional GC. Because of fast peak elution, a time of flight mass spectrometer (TOFMS) is the usual structure-specific detector of choice. The quantitative capabilities of a novel GC×GC fast quadrupole MS were investigated with electron ionization (EI), and CH4 or NH3 positive chemical ionization (PCI) for analysis of endogenous urinary steroids targeted in anti-doping tests. Average precisions for steroid quantitative analysis from replicate urine extractions were 6% (RSD) for EI and 8% for PCI-NH3. The average limits of detection (LOD) calculated by quantification ions for 12 target steroids spiked into steroid-free urine matrix (SFUM) were 2.6 ng mL−1 for EI, 1.3 ng mL−1 for PCI-CH4, and 0.3 ng mL−1 for PCI-NH3, all in mass scanning mode. The measured limits of quantification (LOQ) with full mass scan GC×GC-qMS were comparable with the LOQ values measured by one-dimensional GC-MS in single ion monitoring (SIM) mode. PCI-NH3 yields fewer fragments and greater (pseudo)molecular ion abundances than EI or PCI-CH4. These data show a benchtop GC×GC-qMS system has the sensitivity, specificity, and resolution to analyze urinary steroids at normal urine concentrations, and that PCI-NH3, not currently available on most GC×GC-TOFMS instruments, is of particular value for generation of structure-specific ions. PMID:22606686

  9. Identification of hydroxyropivacaine glucuronide in equine urine by ESI+/MS/MS.

    PubMed Central

    Harkins, J D; Karpiesiuk, W; Tobin, T; Dirikolu, L; Lehner, A F

    2000-01-01

    Ropivacaine is a local anesthetic that has a high potential for abuse in racing horses. It can be recovered from urine collected after administration as a hydroxylated metabolite following beta-glucuronidase treatment of the urine. Based on these findings, it has been inferred that ropivacaine is present in equine urine as a glucuronide metabolite; however, these metabolites have never been directly identified. Using ESI+/MS/MS, the presence of a [M+H]+ molecular ion of m/z 467 was demonstrated in urine corresponding to the calculated mass of a hydroxyropivacaine glucuronide +1. The abundance of this ion diminished after glucuronidase treatment with concomitant appearance of a m/z 291 peak, which is consistent with its hydrolysis to hydroxyropivacaine. In further work, the m/z 467 material was fragmented in the MS/MS system, yielding fragments interpretable as hydroxyropivacaine glucuronide. These data are consistent with the presence of a hydroxyropivacaine glucuronide in equine urine and constitute the first direct demonstration of a specific glucuronide metabolite in equine urine. PMID:10935884

  10. [Clinical significance of monitoring BK polyomavirus in patients after hematopoietic stem cell transplantation].

    PubMed

    Yin, Chang-Xin; Jiang, Qian-Li; He, Han; Yu, Guo-Pan; Xu, Yue; Meng, Fan-Yi; Yang, Mo

    2012-02-01

    This study was aimed to establish a method for rapid detecting BK polyomavirus (BKV) and to investigate the feasibility and value used in leukemia patients undergoing hematopoietic stem cell transplantation. Primers were designed according to BKV gene sequence; the quantitative standards for BKV and a real-time fluorescent quantitative PCR for BKV were established. The BKV level in urine samples from 36 patients after hematopoietic stem cell transplantation were detected by established method. The results showed that the standard of reconstructed plasmid and real time fluorescent quantitative PCR method were successfully established, its good specificity, sensitivity and stability were confirmed by experiments. BKV was found in 55.56% of urine samples, and the BKV load in urine was 2.46 × 10(4) - 7.8 × 10(9) copy/ml. It is concluded that the establishment of real-time fluorescent quantitative PCR for BKV detection provides a method for early diagnosis of the patients with hemorrhagic cystitis after hematopoietic stem cell transplantation.

  11. Identification of fentanyl metabolites in rat urine by gas chromatography-mass spectrometry with stable-isotope tracers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goromaru, T.; Matsuura, H.; Furuta, T.

    The metabolites of fentanyl (l), which has been widely used as a neuroleptic analgesic agent, were identified in urine of rats by gas chromatography-mass spectrometry combined with a stable-isotope tracer technique. After the oral administration of an equimolar mixture of l and deuterium-labeled l (l/l-d5), the urinary metabolites were extracted with chloroform at pH 9.0. Extracts were derivatized and analyzed by GC/MS. Metabolites were identified by the presence of doublet ion peaks separated by 5 amu, and chemical structures were established from analyses of fragmentation pathways. The metabolites were identified as 4-N-(N-propionylanilino)-piperidine, 4-N-(N-hydroxypropionylanilino)piperidine, 4-N-(N-propionylanilino) hydroxypiperidine, 1-(2-phenethyl)-4-N-(N-hydroxypropionylanilino)piperidine and 1-(2-phenethyl)-4-N-(N-propionylanilino)hydroxypiperidine. These metabolites,more » together with unchanged l, were also detected in urine of rats receiving l/l-d5 intravenously, by selected-ion monitoring of the specific cluster ions.« less

  12. Evaluation of some heavy metals concentration in body fluids of metal workers in Kano metropolis, Nigeria.

    PubMed

    Sani, Ali; Abdullahi, Ibrahim Lawal

    2017-01-01

    Metal workers in urban Kano constitute a major workforce with a considerable population. The present work was aimed at obtaining baseline data on the extent of metal ion concentration in body fluids (urine and blood) of sampled population in the area. The investigation involves interaction with sampled population as well as blood and urine sample collection for heavy metals analysis. The health problems associated with the practice identified by respondents include: metal fume fever; eye and skin irritation; dizziness and respiratory problems; lack of or inadequate protective devices during activity were also reported. Laboratory investigation of urine samples by Atomic absorption spectrophotometry indicated higher concentrations for Manganese (Mn), Lead (Pb) and Nickel (Ni); in blood samples, there were higher concentrations of Manganese (Mn), Lead (Pb), Chromium (Cr) and Nickel (Ni). Metal workers of urban Kano are at risk because of the concentration of Mn and Pb in particular. There is the need to monitor occupational activities that are responsible for pollution and with serious health risk.

  13. Determination of tetrahydrozoline in urine and blood using gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Peat, Judy; Garg, Uttam

    2010-01-01

    Tetrahydrozoline, a derivative of imidazoline, is widely used for the symptomatic relief of conjunctival and nasal congestion; however, intentional or unintentional high doses can result in toxicity manifested by hypotension, tachycardia, and CNS depression. The detection of the drug in blood and urine is helpful in the diagnosis and management of a toxic patient. For the analysis, plasma, serum, or urine is added to a tube containing alkaline buffer and organic extraction solvents, and tetrahydrozoline from the sample is extracted into the organic phase by gentle mixing. After centrifugation, the upper organic solvent layer containing the drug is removed and dried under stream of nitrogen at 40 degrees C. The residue is reconstituted in a hexane-ethanol mixture and analyzed using gas-chromatography-mass spectrometry. Quantitation of the drug is done by comparing responses of unknown sample to the responses of the calibrators using selected ion monitoring. Naphazoline is used as an internal standard.

  14. Chicago area methyl parathion response.

    PubMed

    McCann, Kenneth G; Moomey, C Michael; Runkle, Kenny D; Hryhorczuk, Daniel O; Clark, J Milton; Barr, Dana B

    2002-12-01

    The Illinois Department of Public Health participated in the Chicago, Illinois, area methyl parathion (MP) response with several other federal, state, and local government agencies beginning in April 1997. This response was initiated on evidence that hundreds of homes in the Chicago area were illegally treated for cockroaches with MP over a period of several years. Through applicator receipt books and information reported by property owners and tenants, 968 homes were identified as having been treated with MP. Upon implementation of a response plan developed by the Methyl Parathion Health Sciences Steering Committee, environmental sampling and urine monitoring were provided for eligible households. Environmental sampling was conducted in 903 homes, with MP detected above levels of concern in 596 residences. Residents of these homes were offered urine sampling to determine the extent of exposure to MP. Urine samples were collected and analyzed for p-nitrophenol in 1,913 individuals. Implementation of the protocol resulted in 550 residents being relocated during the remediation of 100 households.

  15. Identification of sinensetin metabolites in rat urine by an isotope-labeling method and ultrahigh-performance liquid chromatography-electrospray ionization mass spectrometry.

    PubMed

    Wei, Guor-Jien; Sheen, Jenn-Feng; Lu, Wen-Chien; Hwang, Lucy Sun; Ho, Chi-Tang; Lin, Ching-I

    2013-05-29

    Sinensetin (SIN), one of the major polymethoxyflavones (PMFs) contained mainly in the citrus peels, has been reported to possess various bioactivities, including antifungal, antimutagenic, anticancer, and anti-inflammatory activities. Although the biotransformation of SIN in fungi and insects has been reported, the information about the metabolism of SIN in mammals is still unclear. In this study, formation of SIN metabolites in rats was investigated. Four isotope-labeled SINs ([4'-D3]SIN, [3'-D3]SIN, [5-D3]SIN, and [6-D3]SIN) were synthesized and administered to rat. The urine samples were collected and main metabolites were monitored by ultrahigh-performance liquid chromatography-electrospray ionization mass spectrometry. The administered compound and four SIN metabolites were detected in rat urine. These metabolites were identified as 4'-hydroxy-5,6,7,3'-tetramethoxyflavone, 5-hydroxy-6,7,3',4'-tetramethoxyflavone, 6-hydroxy-5,7,3',4'-tetramethoxyflavone, and 7-hydroxy-5,6,3',4'-tetramethoxyflavone sulfate.

  16. Determination of urine ionic composition with potentiometric multisensor system.

    PubMed

    Yaroshenko, Irina; Kirsanov, Dmitry; Kartsova, Lyudmila; Sidorova, Alla; Borisova, Irina; Legin, Andrey

    2015-01-01

    The ionic composition of urine is a good indicator of patient's general condition and allows for diagnostics of certain medical problems such as e.g., urolithiasis. Due to environmental factors and malnutrition the number of registered urinary tract cases continuously increases. Most of the methods currently used for urine analysis are expensive, quite laborious and require skilled personnel. The present work deals with feasibility study of potentiometric multisensor system of 18 ion-selective and cross-sensitive sensors as an analytical tool for determination of urine ionic composition. In total 136 samples from patients of Urolithiasis Laboratory and healthy people were analyzed by the multisensor system as well as by capillary electrophoresis as a reference method. Various chemometric approaches were implemented to relate the data from electrochemical measurements with the reference data. Logistic regression (LR) was applied for classification of samples into healthy and unhealthy producing reasonable misclassification rates. Projection on Latent Structures (PLS) regression was applied for quantitative analysis of ionic composition from potentiometric data. Mean relative errors of simultaneous prediction of sodium, potassium, ammonium, calcium, magnesium, chloride, sulfate, phosphate, urate and creatinine from multisensor system response were in the range 3-13% for independent test sets. This shows a good promise for development of a fast and inexpensive alternative method for urine analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. 21 CFR 862.1590 - Porphobilinogen test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... intended to measure porphobilinogen (one of the derivatives of hemoglobin which can make the urine a red color) in urine. Measurements obtained by this device are used in the diagnosis and treatment of...

  18. 21 CFR 862.1377 - Urinary homocystine (nonquantitative) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... analogue of the amino acid cystine) in urine. The identification of urinary homocystine is used in the diagnosis and treatment of homocystinuria (homosystine in urine), a heritable metabolic disorder which may...

  19. 21 CFR 862.1377 - Urinary homocystine (nonquantitative) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... analogue of the amino acid cystine) in urine. The identification of urinary homocystine is used in the diagnosis and treatment of homocystinuria (homosystine in urine), a heritable metabolic disorder which may...

  20. 21 CFR 862.1590 - Porphobilinogen test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... intended to measure porphobilinogen (one of the derivatives of hemoglobin which can make the urine a red color) in urine. Measurements obtained by this device are used in the diagnosis and treatment of...

Top