Sample records for urine radiobioassay intercomparison

  1. EURADOS intercomparison on emergency radiobioassay.

    PubMed

    Li, Chunsheng; Battisti, Paolo; Berard, Philippe; Cazoulat, Alain; Cuellar, Antonio; Cruz-Suarez, Rodolfo; Dai, Xiongxin; Giardina, Isabella; Hammond, Derek; Hernandez, Carolina; Kiser, Stephen; Ko, Raymond; Kramer-Tremblay, Sheila; Lecompte, Yannick; Navarro, Eva; Navas, Cristina; Sadi, Baki; Sierra, Inmaculada; Verrezen, Freddy; Lopez, Maria A

    2015-12-01

    Nine laboratories participated in an intercomparison exercise organised by the European Radiation Dosimetry Group (EURADOS) for emergency radiobioassay involving four high-risk radionuclides ((239)Pu, (241)Am, (90)Sr and (226)Ra). Diverse methods of analysis were used by the participating laboratories for the in vitro determination of each of the four radionuclides in urine samples. Almost all the methods used are sensitive enough to meet the requirements for emergency radiobioassay derived for this project in reference to the Clinical Decision Guide introduced by the NCRP. Results from most of the methods meet the requirements of ISO 28218 on accuracy in terms of relative bias and relative precision. However, some technical gaps have been identified. For example, some laboratories do not have the ability to assay samples containing (226)Ra, and sample turnaround time would be expected to be much shorter than that reported by many laboratories, as timely results for internal contamination and early decisions on medical intervention are highly desired. Participating laboratories are expected to learn from each other on the methods used to improve the interoperability among these laboratories. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Emergency radiobioassay preparedness exercises through the NIST radiochemistry intercomparison program.

    PubMed

    Nour, Svetlana; LaRosa, Jerry; Inn, Kenneth G W

    2011-08-01

    The present challenge for the international emergency radiobioassay community is to analyze contaminated samples rapidly while maintaining high quality results. The National Institute of Standards and Technology (NIST) runs a radiobioassay measurement traceability testing program to evaluate the radioanalytical capabilities of participating laboratories. The NIST Radiochemistry Intercomparison Program (NRIP) started more than 10 years ago, and emergency performance testing was added to the program seven years ago. Radiobioassay turnaround times under the NRIP program for routine production and under emergency response scenarios are 60 d and 8 h, respectively. Because measurement accuracy and sample turnaround time are very critical in a radiological emergency, response laboratories' analytical systems are best evaluated and improved through traceable Performance Testing (PT) programs. The NRIP provides participant laboratories with metrology tools to evaluate their performance and to improve it. The program motivates the laboratories to optimize their methodologies and minimize the turnaround time of their results. Likewise, NIST has to make adjustments and periodical changes in the bioassay test samples in order to challenge the participating laboratories continually. With practice, radioanalytical measurements turnaround time can be reduced to 3-4 h.

  3. Excreta Sampling as an Alternative to In Vivo Measurements at the Hanford Site.

    PubMed

    Carbaugh, Eugene H; Antonio, Cheryl L; Lynch, Timothy P

    2015-08-01

    The capabilities of indirect radiobioassay by urine and fecal sample analysis were compared with the direct radiobioassay methods of whole body counting and lung counting for the most common radionuclides and inhalation exposure scenarios encountered by Hanford workers. Radionuclides addressed by in vivo measurement included 137Cs, 60Co, 154Eu, and 241Am as an indicator for plutonium mixtures. The same radionuclides were addressed using gamma energy analysis of urine samples, augmented by radiochemistry and alpha spectrometry methods for plutonium in urine and fecal samples. It was concluded that in vivo whole body counting and lung counting capability should be maintained at the Hanford Site for the foreseeable future, however, urine and fecal sample analysis could provide adequate, though degraded, monitoring capability for workers as a short-term alternative, should in vivo capability be lost due to planned or unplanned circumstances.

  4. DOE standard: The Department of Energy Laboratory Accreditation Program for radiobioassay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-01

    This technical standard describes the US Department of Energy Laboratory Accreditation Program (DOELAP) for Radiobioassay, for use by the US Department of Energy (DOE) and DOE Contractor radiobioassay programs. This standard is intended to be used in conjunction with the general administrative technical standard that describes the overall DOELAP accreditation process--DOE-STD-1111-98, Department of Energy Laboratory Accreditation Program Administration. This technical standard pertains to radiobioassay service laboratories that provide either direct or indirect (in vivo or in vitro) radiobioassay measurements in support of internal dosimetry programs at DOE facilities or for DOE and DOE contractors. Similar technical standards have been developedmore » for other DOELAP dosimetry programs. This program consists of providing an accreditation to DOE radiobioassay programs based on successful completion of a performance-testing process and an on-site evaluation by technical experts. This standard describes the technical requirements and processes specific to the DOELAP Radiobioassay Accreditation Program as required by 10 CFR 835 and as specified generically in DOE-STD-1111-98.« less

  5. Investigation of magnetic nanoparticles for the rapid extraction and assay of alpha-emitting radionuclides from urine: Demonstration of a novel radiobioassay method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Hara, Matthew J.; Carter, Jennifer C.; Maclellan, Jay A.

    2011-08-01

    In the event of an accidental or intentional release of radionuclides into a populated area, three things must occur in a timely manner: food and drinking water supplies must be determined to be safe to eat / drink, civilians and/or military personnel must be surveyed to ensure that they do not have external contamination, and they must be screened to ensure that significant ingestion or inhalation of radionuclides has not occurred (this paper is concerned with the latter). In the event of such a disaster, the volume of radiobioassays to be performed would be tremendous. If the event released significantmore » levels of β- or α-emitting radionuclides, in vivo assays would be ineffective. Therefore, highly efficient and rapid analytical methods for radionuclide detection from submitted spot urine samples (≤ 50 mL) would be required. At present, the quantitative determination of α-emitting radionuclides from urine samples is highly labor intensive, and requires significant sample preparation and analysis time. Sorbent materials that provide effective collection and enable rapid assay could significantly streamline the radioanalytical process. We have demonstrated the use of paramagnetic nanoparticles as a novel class of extracting media for four α-emitting radionuclides of concern (Po, Ra, Am, and U) from chemically unmodified and pH 2 human urine. Herein the initial experimental sorption results are presented along with a novel method that utilizes paramagnetic nanoparticles for the extraction of radionuclides from unmodified human urine followed by the magnetic field-induced collection of the particles for subsequent α-counting-source preparation. Additionally, we construct a versatile human dose model that determines the detector count times required to estimate internal human dose at specific protective action thresholds. The model provides a means to assess a method’s detection capabilities and use fundamental health physics parameters and actual experimental data as core variables. The modeling shows that with effective sorbent materials, rapid screening for internalized α-emitters is possible from a 50 mL spot urine sample volume collected within one week of exposure/intake.« less

  6. Intercomparison of analytical methods for arsenic speciation in human urine.

    PubMed

    Crecelius, E; Yager, J

    1997-06-01

    An intercomparison exercise was conducted for the quantification of arsenic species in spiked human urine. The primary objective of the exercise was to determine the variance among laboratories in the analysis of arsenic species such as inorganic As (As+3 and As+5), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA). Laboratories that participated had previous experience with arsenic speciation analysis. The results of this interlaboratory comparison are encouraging. There is relatively good agreement on the concentrations of these arsenic species in urine at concentrations that are relevant to research on the metabolism of arsenic in humans and other mammals. Both the accuracy and precision are relatively poor for arsenic concentrations of less than about 5 micrograms/l.

  7. Intercomparison of analytical methods for arsenic speciation in human urine.

    PubMed Central

    Crecelius, E; Yager, J

    1997-01-01

    An intercomparison exercise was conducted for the quantification of arsenic species in spiked human urine. The primary objective of the exercise was to determine the variance among laboratories in the analysis of arsenic species such as inorganic As (As+3 and As+5), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA). Laboratories that participated had previous experience with arsenic speciation analysis. The results of this interlaboratory comparison are encouraging. There is relatively good agreement on the concentrations of these arsenic species in urine at concentrations that are relevant to research on the metabolism of arsenic in humans and other mammals. Both the accuracy and precision are relatively poor for arsenic concentrations of less than about 5 micrograms/l. PMID:9288500

  8. Carbon-14 bioassay for decommissioning of Hanford reactors.

    PubMed

    Carbaugh, Eugene H; Watson, David J

    2012-05-01

    The production reactors at the U.S. Department of Energy Hanford Site used large graphite piles as the moderator. As part of long-term decommissioning plans, the potential need for ¹⁴C radiobioassay of workers was identified. Technical issues associated with ¹⁴C bioassay and worker monitoring were investigated, including anticipated graphite characterization, potential intake scenarios, and the bioassay capabilities that may be required to support the decommissioning of the graphite piles. A combination of urine and feces sampling would likely be required for the absorption type S ¹⁴C anticipated to be encountered. However, the concentrations in the graphite piles appear to be sufficiently low that dosimetrically significant intakes of ¹⁴C are not credible, thus rendering moot the need for such bioassay.

  9. Carbon-14 Bioassay for Decommissioning of Hanford Reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.; Watson, David J.

    2012-05-01

    The old production reactors at the US Department of Energy Hanford Site used large graphite piles as the moderator. As part of long-term decommissioning plans, the potential need for 14C radiobioassay of workers was identified. Technical issues associated with 14C bioassay and worker monitoring were investigated, including anticipated graphite characterization, potential intake scenarios, and the bioassay capabilities that may be required to support the decommissioning of the graphite piles. A combination of urine and feces sampling would likely be required for the absorption type S 14C anticipated to be encountered. However the concentrations in the graphite piles appear to bemore » sufficiently low that dosimetrically significant intakes of 14C are not credible, thus rendering moot the need for such bioassay.« less

  10. AN INTERLABORATORY COMPARISON ON THE DETERMINATION OF 241Am, 244Cm AND 252Cf IN URINE.

    PubMed

    Gerstmann, Udo C; Taubner, Kerstin; Hartmann, Martina

    2016-09-01

    An intercomparison exercise on the determination of (241)Am, (244)Cm and (252)Cf in urine was performed. Since it was designed with regard to emergency preparedness, the detection limit for each nuclide was set to 0.1 Bq per 24-h urine sample. Most of the participating laboratories were established bioassay laboratories. However, some laboratories that routinely determine (241)Am only in environmental samples were also invited in order to explore their potential for emergency bioassay analysis. Another aspect of the intercomparison was to investigate the performance of all laboratories concerning the chemical yields of the (243)Am tracer in comparison with (244)Cm and (252)Cf. In summary, both types of laboratories showed good results. There was a negative bias for the results of (244)Cm and (252)Cf, which can be explained by slightly different radiochemical behaviours of americium, curium and californium and which is in agreement with results reported in the literature. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. 42 CFR 493.643 - Fee for determination of program compliance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... antibody identification. (vi) The specialty of Pathology, which includes the following subspecialties: (A) Cytology. (B) Histopathology. (C) Oral pathology. (vii) The specialty of Radiobioassay. (viii) The...

  12. Internal dosimetry technical basis manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-12-20

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophicalmore » discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs.« less

  13. Implementation of ICP-MS protocols for uranium urinary measurements in worker monitoring.

    PubMed

    Baglan, N; Cossonnet, C; Trompier, F; Ritt, J; Bérard, P

    1999-10-01

    The uranium concentration in human urine spiked with natural uranium and rat urine containing metabolized depleted uranium was determined by ICP-MS. The use of ICP-MS was investigated without any chemical treatment or after the different stages of a purification protocol currently carried out for routine monitoring. In the case of spiked urine, the measured uranium concentrations were consistent with those certified by an intercomparison network in radiotoxicological analysis (PROCORAD) and with those obtained by alpha spectrometry in the case of the urine containing metabolized uranium. The quantitative information which could be obtained in the different protocols investigated shows the extent to which ICP-MS provides greater flexibility for setting up appropriate monitoring approaches in radiation protection routines and accidental situations. This is due to the combination of high sensitivity and the accuracy with which traces of uranium in urine can be determined in a shorter time period. Moreover, it has been shown that ICP-MS measurement can be used to quantify the 235U isotope, which is useful for characterizing the nature of the uranium compound, but difficult to perform using alpha spectrometry.

  14. Methods and Models of the Hanford Internal Dosimetry Program, PNNL-MA-860

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.

    2003-01-03

    This manual describes the technical basis for the design of the routine radiobioassay monitoring program and assessments of internal dose. Its purpose is to provide a historical record of the methods, models, and assumptions used for internal dosimetry at Hanford, and serve as a technical reference for radiation protection and dosimetry staff.

  15. A Bayesian Method for Identifying Contaminated Detectors in Low-Level Alpha Spectrometers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maclellan, Jay A.; Strom, Daniel J.; Joyce, Kevin E.

    2011-11-02

    Analyses used for radiobioassay and other radiochemical tests are normally designed to meet specified quality objectives, such relative bias, precision, and minimum detectable activity (MDA). In the case of radiobioassay analyses for alpha emitting radionuclides, a major determiner of the process MDA is the instrument background. Alpha spectrometry detectors are often restricted to only a few counts over multi-day periods in order to meet required MDAs for nuclides such as plutonium-239 and americium-241. A detector background criterion is often set empirically based on experience, or frequentist or classical statistics are applied to the calculated background count necessary to meet amore » required MDA. An acceptance criterion for the detector background is set at the multiple of the estimated background standard deviation above the assumed mean that provides an acceptably small probability of observation if the mean and standard deviation estimate are correct. The major problem with this method is that the observed background counts used to estimate the mean, and thereby the standard deviation when a Poisson distribution is assumed, are often in the range of zero to three counts. At those expected count levels it is impossible to obtain a good estimate of the true mean from a single measurement. As an alternative, Bayesian statistical methods allow calculation of the expected detector background count distribution based on historical counts from new, uncontaminated detectors. This distribution can then be used to identify detectors showing an increased probability of contamination. The effect of varying the assumed range of background counts (i.e., the prior probability distribution) from new, uncontaminated detectors will be is discussed.« less

  16. Low-cost solar array project: Four absolute cavity radiometer (pyrheliometer) intercomparisons at New River, Arizona: Radiometer standards

    NASA Technical Reports Server (NTRS)

    Estey, R. S.; Seaman, C. H.

    1981-01-01

    Four detailed intercomparisons were made for a number of models of cavity-type self-calibrating radiometers (pyrheliometers). Each intercomparison consisted of simultaneous readings of pyrheliometers at 30-second intervals in runs of 10 minutes, with at least 15 runs per intercomparison. Twenty-seven instruments were in at least one intercomparison, and five were in all four. Summarized results and all raw data are provided from the intercomparisons.

  17. Indoor and Outdoor Spectroradiometer Intercomparison for Spectral Irradiance Measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habte, A.; Andreas, A.; Ottoson, L.

    2014-05-01

    This report details the global spectral irradiance intercomparison using spectroradiometers that was organized by the National Renewable Energy Laboratory's Solar Radiation Research Laboratory. The intercomparison was performed both indoors and outdoors on September 17, 2013. Five laboratories participated in the intercomparison using 10 spectroradiometers, and a coordinated measurement setup and a common platform were employed to compare spectral irradiances under both indoor and outdoor conditions. The intercomparison aimed to understand the performance of the different spectroradiometers and to share knowledge in making spectral irradiance measurements. This intercomparison was the first of its kind in the United States.

  18. Agricultural model intercomparison and improvement project: Overview of model intercomparisons

    USDA-ARS?s Scientific Manuscript database

    Improvement of crop simulation models to better estimate growth and yield is one of the objectives of the Agricultural Model Intercomparison and Improvement Project (AgMIP). The overall goal of AgMIP is to provide an assessment of crop model through rigorous intercomparisons and evaluate future clim...

  19. INTERCOMPARISON OF OPTICAL REMOTE SENSING SYSTEMS FOR ROADSIDE MEASUREMENTS

    EPA Science Inventory

    The presentation describes results of an intercomparison of three optical remote sensing systems for measurements of nitric oxide emitted from passenger cars and light-duty trucks. The intercomparison included a standards comparison to establish comparability of standards, follo...

  20. Field test to intercompare carbon monoxide, nitric oxide and hydroxyl instrumentation at Wallops Island, Virginia

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Beck, Sherwin M.; Bendura, Richard J.

    1987-01-01

    Documentation of the first of three instrument intercomparisons conducted as part of NASA Global Tropospheric Experiment/Chemical Instrumentation Test and Evaluation (GTE/CITE-1) is given. This ground-based intercomparison was conducted during July 1983 at NASA Wallops Flight Facility. Instruments intercompared included one laser system and three grab-sample approaches for CO; two chemiluminescent systems and one laser-induced fluorescent (LIF) technique for NO; and two different LIF systems and a radiochemical tracer technique for OH. The major objectives of this intercomparison was to intercompare ambient measurements of CO, NO, and OH at a common site by using techniques of fundamentally different detection principles and to identify any major biases among the techniques prior to intercomparison on an aircraft platform. Included in the report are comprehensive discussions of workshop requirements, philosophies, and operations as well as intercomparison analyses and results. In addition, the large body of nonintercomparison data incorporated into the workshop measurements is summarized. The report is an important source document for those interested in conducting similar large and complex intercomparison tests as well as those interested in using the data base for purposes other than instrument intercomparison.

  1. RESULTS FROM THE NORTH AMERICAN MERCURY MODEL INTER-COMPARISON STUDY (NAMMIS)

    EPA Science Inventory

    A North American Mercury Model Intercomparison Study (NAMMIS) has been conducted to build upon the findings from previous mercury model intercomparison in Europe. In the absence of mercury measurement networks sufficient for model evaluation, model developers continue to rely on...

  2. Accuracy of tretyakov precipitation gauge: Result of wmo intercomparison

    USGS Publications Warehouse

    Yang, Daqing; Goodison, Barry E.; Metcalfe, John R.; Golubev, Valentin S.; Elomaa, Esko; Gunther, Thilo; Bates, Roy; Pangburn, Timothy; Hanson, Clayton L.; Emerson, Douglas G.; Copaciu, Voilete; Milkovic, Janja

    1995-01-01

    The Tretyakov non-recording precipitation gauge has been used historically as the official precipitation measurement instrument in the Russian (formerly the USSR) climatic and hydrological station network and in a number of other European countries. From 1986 to 1993, the accuracy and performance of this gauge were evaluated during the WMO Solid Precipitation Measurement Intercomparison at 11 stations in Canada, the USA, Russia, Germany, Finland, Romania and Croatia. The double fence intercomparison reference (DFIR) was the reference standard used at all the Intercomparison stations in the Intercomparison. The Intercomparison data collected at the different sites are compatible with respect to the catch ratio (measured/DFIR) for the same gauge, when compared using mean wind speed at the height of the gauge orifice during the observation period.The Intercomparison data for the Tretyakov gauge were compiled from measurements made at these WMO intercomparison sites. These data represent a variety of climates, terrains and exposures. The effects of environmental factors, such as wind speed, wind direction, type of precipitation and temperature, on gauge catch ratios were investigated. Wind speed was found to be the most important factor determining the gauge catch and air temperature had a secondary effect when precipitation was classified into snow, mixed and rain. The results of the analysis of gauge catch ratio versus wind speed and temperature on a daily time step are presented for various types of precipitation. Independent checks of the correction equations against the DFIR have been conducted at those Intercomparison stations and a good agreement (difference less than 10%) has been obtained. The use of such adjustment procedures should significantly improve the accuracy and homogeneity of gauge-measured precipitation data over large regions of the former USSR and central Europe.

  3. Operational overview of NASA GTE/CITE 1 airborne instrument intercomparisons - Carbon monoxide, nitric oxide, and hydroxyl instrumentation. [Global Tropospheric Experiment/Chemical Instrumentation Test and Evaluation

    NASA Technical Reports Server (NTRS)

    Beck, Sherwin M.; Bendura, Richard J.; Mcdougal, David S.; Hoell, James M., Jr.; Gregory, Gerald L.; Sachse, Glen W.; Hill, Gerald F.; Curfman, Howard J., Jr.; Torres, Arnold L.; Condon, Estelle P.

    1987-01-01

    An overview of the airborne intercomparisons of CO, NO, and OH instrumentation is presented in this first paper of the series on the NASA Global Tropospheric Experiment/Chemical Instrumentation Test and Evaluation (GTE/CITE 1). This paper provides the reader with background information about several important characteristics of the project. These include the overall objectives and approach, the measurements taken, the intercomparison protocol, aircraft platform, profiles of each aircraft flight, and the participants. A synopsis of the overall results of the CO, NO, and OH instrument intercomparisons is also included. Companion papers discuss the detailed results of the CO and NO intercomparison tests as well as pertinent scientific findings.

  4. The agricultural model intercomparison and improvement project (AgMIP): Protocols and pilot studies

    USDA-ARS?s Scientific Manuscript database

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) is a distributed climate-scenario simulation research activity for historical period model intercomparison and future climate change conditions with participation of multiple crop and agricultural economic model groups around the...

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goke, Sarah Hayes; Elliott, Nathan Ryan

    The Sandia National Laboratories’ Internal Dosimetry Technical Basis Manual is intended to provide extended technical discussion and justification of the internal dosimetry program at SNL. It serves to record the approach to evaluating internal doses from radiobioassay data, and where appropriate, from workplace monitoring data per the Department of Energy Internal Dosimetry Program Guide DOE G 441.1C. The discussion contained herein is directed primarily to current and future SNL internal dosimetrists. In an effort to conserve space in the TBM and avoid duplication, it contains numerous references providing an entry point into the internal dosimetry literature relevant to this program.more » The TBM is not intended to act as a policy or procedure statement, but will supplement the information normally found in procedures or policy documents. The internal dosimetry program outlined in this manual is intended to meet the requirements of Federal Rule 10CFR835 for monitoring the workplace and for assessing internal radiation doses to workers.« less

  6. Comprehensive Australasian multicentre dosimetric intercomparison: issues, logistics and recommendations.

    PubMed

    Ebert, M A; Harrison, K M; Cornes, D; Howlett, S J; Joseph, D J; Kron, T; Hamilton, C S; Denham, J W

    2009-02-01

    The present paper describes the logistics of the 2004-2008 Australasian Level III Dosimetry Intercomparison. Dosimetric intercomparisons (or 'audits') can be used in radiotherapy to evaluate the accuracy and quality of radiation delivery. An intercomparison was undertaken in New Zealand and Australia to evaluate the feasibility and logistics of ongoing dosimetric intercomparisons that evaluate all steps in the radiotherapy treatment process, known as a 'Level III' intercomparison. The study commenced in 2002 with the establishment of a study team, definition of the study protocol, acquisition of appropriate equipment and recruitment of participating radiotherapy centres. Measurements were undertaken between October 2004 and March 2008, and included collation of data on time, costs and logistics of the study. Forty independent Australian and New Zealand radiotherapy centres agreed to participate. Measurement visits were made to 37 of these centres. Data is presented on the costs of the study and the level of support required. The study involved the participation of 16 staff at the study centre who invested over 4000 hours in the study, and of over 200 professionals at participating centres. Recommendations are provided for future phantom-based intercomparisons. It is hoped that the present paper will be of benefit to any centres or groups contemplating similar activities by identifying the processes involved in establishing the study, the potential hazards and pitfalls, and expected resource requirements.

  7. Intercomparison of hydrologic processes in global climate models

    NASA Technical Reports Server (NTRS)

    Lau, W. K.-M.; Sud, Y. C.; Kim, J.-H.

    1995-01-01

    In this report, we address the intercomparison of precipitation (P), evaporation (E), and surface hydrologic forcing (P-E) for 23 Atmospheric Model Intercomparison Project (AMIP) general circulation models (GCM's) including relevant observations, over a variety of spatial and temporal scales. The intercomparison includes global and hemispheric means, latitudinal profiles, selected area means for the tropics and extratropics, ocean and land, respectively. In addition, we have computed anomaly pattern correlations among models and observations for different seasons, harmonic analysis for annual and semiannual cycles, and rain-rate frequency distribution. We also compare the joint influence of temperature and precipitation on local climate using the Koeppen climate classification scheme.

  8. Airborne sulfur trace species intercomparison campaign: Sulfur dioxide, dimethylsulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Hoell, James M., Jr.; Davis, Douglas D.

    1991-01-01

    Results from an airborne intercomparison of techniques to measure tropospheric levels of sulfur trace gases are presented. The intercomparison was part of the NASA Global Tropospheric Experiment (GTE) and was conducted during the summer of 1989. The intercomparisons were conducted on the Wallops Electra aircraft during flights from Wallops Island, Virginia, and Natal, Brazil. Sulfur measurements intercompared included sulfur dioxide (SO2), dimethylsulfide (DMS), hydrogen sulfide (H2S), carbon disulfide (CS2), and carbonyl sulfide (OCS). Measurement techniques ranged from filter collection systems with post-flight analyses to mass spectrometer and gas chromatograph systems employing various methods for measuring and identifying the sulfur gases during flight. Sampling schedules for the techniques ranged from integrated collections over periods as long as 50 minutes to one- to three-minute samples every ten or fifteen minutes. Several of the techniques provided measurements of more than one sulfur gas. Instruments employing different detection principles were involved in each of the sulfur intercomparisons. Also included in the intercomparison measurement scenario were a host of supporting measurements (i.e., ozone, nitrogen oxides, carbon monoxide, total sulfur, aerosols, etc.) for purposes of: (1) interpreting results (i.e., correlation of any noted instrument disagreement with the chemical composition of the measurement environment); and (2) providing supporting chemical data to meet CITE-3 science objectives of studying ozone/sulfur photochemistry, diurnal cycles, etc. The results of the intercomparison study are briefly discussed.

  9. KEY COMPARISON: Final report on CCQM-K69 key comparison: Testosterone glucuronide in human urine

    NASA Astrophysics Data System (ADS)

    Liu, Fong-Ha; Mackay, Lindsey; Murby, John

    2010-01-01

    The CCQM-K69 key comparison of testosterone glucuronide in human urine was organized under the auspices of the CCQM Organic Analysis Working Group (OAWG). The National Measurement Institute Australia (NMIA) acted as the coordinating laboratory for the comparison. The samples distributed for the key comparison were prepared at NMIA with funding from the World Anti-Doping Agency (WADA). WADA granted the approval for this material to be used for the intercomparison provided the distribution and handling of the material were strictly controlled. Three national metrology institutes (NMIs)/designated institutes (DIs) developed reference methods and submitted data for the key comparison along with two other laboratories who participated in the parallel pilot study. A good selection of analytical methods and sample workup procedures was displayed in the results submitted considering the complexities of the matrix involved. The comparability of measurement results was successfully demonstrated by the participating NMIs. Only the key comparison data were used to estimate the key comparison reference value (KCRV), using the arithmetic mean approach. The reported expanded uncertainties for results ranged from 3.7% to 6.7% at the 95% level of confidence and all results agreed within the expanded uncertainty of the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. Pliocene Model Intercomparison Project (PlioMIP): Experimental Design and Boundary Conditions (Experiment 2)

    NASA Technical Reports Server (NTRS)

    Haywood, A. M.; Dowsett, H. J.; Robinson, M. M.; Stoll, D. K.; Dolan, A. M.; Lunt, D. J.; Otto-Bliesner, B.; Chandler, M. A.

    2011-01-01

    The Palaeoclimate Modelling Intercomparison Project has expanded to include a model intercomparison for the mid-Pliocene warm period (3.29 to 2.97 million yr ago). This project is referred to as PlioMIP (the Pliocene Model Intercomparison Project). Two experiments have been agreed upon and together compose the initial phase of PlioMIP. The first (Experiment 1) is being performed with atmosphere only climate models. The second (Experiment 2) utilizes fully coupled ocean-atmosphere climate models. Following on from the publication of the experimental design and boundary conditions for Experiment 1 in Geoscientific Model Development, this paper provides the necessary description of differences and/or additions to the experimental design for Experiment 2.

  11. Pliocene Model Intercomparison Project (PlioMIP): experimental design and boundary conditions (Experiment 2)

    USGS Publications Warehouse

    Haywood, A.M.; Dowsett, H.J.; Robinson, M.M.; Stoll, D.K.; Dolan, A.M.; Lunt, D.J.; Otto-Bliesner, B.; Chandler, M.A.

    2011-01-01

    The Palaeoclimate Modelling Intercomparison Project has expanded to include a model intercomparison for the mid-Pliocene warm period (3.29 to 2.97 million yr ago). This project is referred to as PlioMIP (the Pliocene Model Intercomparison Project). Two experiments have been agreed upon and together compose the initial phase of PlioMIP. The first (Experiment 1) is being performed with atmosphere-only climate models. The second (Experiment 2) utilises fully coupled ocean-atmosphere climate models. Following on from the publication of the experimental design and boundary conditions for Experiment 1 in Geoscientific Model Development, this paper provides the necessary description of differences and/or additions to the experimental design for Experiment 2.

  12. Manufacture and calibration of optical supersmooth roughness artifacts for intercomparisons

    NASA Astrophysics Data System (ADS)

    Ringel, Gabriele A.; Kratz, Frank; Schmitt, Dirk-Roger; Mangelsdorf, Juergen; Creuzet, Francois; Garratt, John D.

    1995-09-01

    Intercomparison roughness measurements have been carried out on supersmooth artifacts fabricated from BK7, fused silica, and Zerodur. The surface parameters were determined using the optical heterodyne profiler Z5500 (Zygo), a special prototype of the mechanical profiler Nanostep (Rank Taylor Hobson), and an Atomic Force Microscope (Park Scientific Instruments) with an improved acquisition technique. The intercomparison was performed after the range of collected spatial wavelengths for each instrument was adjusted using digital filtering techniques. It is demonstrated for different roughness ranges that the applied superpolishing techniques yield supersmooth artifacts which can be used for more intercomparisons. More than 100 samples were investigated. Criteria were developed to select artifacts from the sample stock.

  13. Invited Article: Radon and thoron intercomparison experiments for integrated monitors at NIRS, Japan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Janik, M., E-mail: mirek@fml.nirs.go.jp; Ishikawa, T.; Omori, Y.

    Inhalation of radon ({sup 222}Rn) and its short-lived decay products and of products of the thoron ({sup 220}Rn) series accounts for more than half of the effective dose from natural radiation sources. At this time, many countries have begun large-scale radon and thoron surveys and many different measurement methods and instruments are used in these studies. Consequently, it is necessary to improve and standardize technical methods of measurements and to verify quality assurance by intercomparisons between laboratories. Four international intercomparisons for passive integrating radon and thoron monitors were conducted at the NIRS (National Institute of Radiological Sciences, Japan). Radon exercisesmore » were carried out in the 24.4 m{sup 3} inner volume walk-in radon chamber that has systems to control radon concentration, temperature, and humidity. Moreover, the NIRS thoron chamber with a 150 dm{sup 3} inner volume was utilized to provide three thoron intercomparisons. At present, the NIRS is the only laboratory world-wide that has carried out periodic thoron intercomparison of passive monitors. Fifty laboratories from 26 countries participated in the radon intercomparison, using six types of detectors (charcoal, CR-39, LR 115, polycarbonate film, electret plate, and silicon photodiode). Eighteen laboratories from 12 countries participated in the thoron intercomparisons, using two etch-track types (CR-39 and polycarbonate) detectors. The tests were made under one to three different exposures to radon and thoron. The data presented in this paper indicated that the performance quality of laboratories for radon measurement has been gradually increasing. Results of thoron exercises showed that the quality for thoron measurements still needs further development and additional studies are needed to improve its measuring methods. The present paper provides a summary of all radon and thoron international intercomparisons done at NIRS from 2007 to date and it describes the present status on radon and thoron passive, one-time cycle monitors.« less

  14. Pliocene Model Intercomparison (PlioMIP) Phase 2: Scientific Objectives and Experimental Design

    NASA Technical Reports Server (NTRS)

    Haywood, A. M.; Dowsett, H. J.; Dolan, A. M.; Rowley, D.; Abe-Ouchi, A.; Otto-Bliesner, B.; Chandler, M. A.; Hunter, S. J.; Lunt, D. J.; Pound, M.; hide

    2015-01-01

    The Pliocene Model Intercomparison Project (PlioMIP) is a co-ordinated international climate modelling initiative to study and understand climate and environments of the Late Pliocene, and their potential relevance in the context of future climate change. PlioMIP operates under the umbrella of the Palaeoclimate Modelling Intercomparison Project (PMIP), which examines multiple intervals in Earth history, the consistency of model predictions in simulating these intervals and their ability to reproduce climate signals preserved in geological climate archives. This paper provides a thorough model intercomparison project description, and documents the experimental design in a detailed way. Specifically, this paper describes the experimental design and boundary conditions that will be utilized for the experiments in Phase 2 of PlioMIP.

  15. Design and results of the ice sheet model initialisation experiments initMIP-Greenland: an ISMIP6 intercomparison

    NASA Astrophysics Data System (ADS)

    Goelzer, Heiko; Nowicki, Sophie; Edwards, Tamsin; Beckley, Matthew; Abe-Ouchi, Ayako; Aschwanden, Andy; Calov, Reinhard; Gagliardini, Olivier; Gillet-Chaulet, Fabien; Golledge, Nicholas R.; Gregory, Jonathan; Greve, Ralf; Humbert, Angelika; Huybrechts, Philippe; Kennedy, Joseph H.; Larour, Eric; Lipscomb, William H.; Le clec'h, Sébastien; Lee, Victoria; Morlighem, Mathieu; Pattyn, Frank; Payne, Antony J.; Rodehacke, Christian; Rückamp, Martin; Saito, Fuyuki; Schlegel, Nicole; Seroussi, Helene; Shepherd, Andrew; Sun, Sainan; van de Wal, Roderik; Ziemen, Florian A.

    2018-04-01

    Earlier large-scale Greenland ice sheet sea-level projections (e.g. those run during the ice2sea and SeaRISE initiatives) have shown that ice sheet initial conditions have a large effect on the projections and give rise to important uncertainties. The goal of this initMIP-Greenland intercomparison exercise is to compare, evaluate, and improve the initialisation techniques used in the ice sheet modelling community and to estimate the associated uncertainties in modelled mass changes. initMIP-Greenland is the first in a series of ice sheet model intercomparison activities within ISMIP6 (the Ice Sheet Model Intercomparison Project for CMIP6), which is the primary activity within the Coupled Model Intercomparison Project Phase 6 (CMIP6) focusing on the ice sheets. Two experiments for the large-scale Greenland ice sheet have been designed to allow intercomparison between participating models of (1) the initial present-day state of the ice sheet and (2) the response in two idealised forward experiments. The forward experiments serve to evaluate the initialisation in terms of model drift (forward run without additional forcing) and in response to a large perturbation (prescribed surface mass balance anomaly); they should not be interpreted as sea-level projections. We present and discuss results that highlight the diversity of data sets, boundary conditions, and initialisation techniques used in the community to generate initial states of the Greenland ice sheet. We find good agreement across the ensemble for the dynamic response to surface mass balance changes in areas where the simulated ice sheets overlap but differences arising from the initial size of the ice sheet. The model drift in the control experiment is reduced for models that participated in earlier intercomparison exercises.

  16. Design and results of the ice sheet model initialisation experiments initMIP-Greenland: an ISMIP6 intercomparison

    DOE PAGES

    Goelzer, Heiko; Nowicki, Sophie; Edwards, Tamsin; ...

    2018-04-19

    Earlier large-scale Greenland ice sheet sea-level projections (e.g. those run during the ice2sea and SeaRISE initiatives) have shown that ice sheet initial conditions have a large effect on the projections and give rise to important uncertainties. Here, the goal of this initMIP-Greenland intercomparison exercise is to compare, evaluate, and improve the initialisation techniques used in the ice sheet modelling community and to estimate the associated uncertainties in modelled mass changes. initMIP-Greenland is the first in a series of ice sheet model intercomparison activities within ISMIP6 (the Ice Sheet Model Intercomparison Project for CMIP6), which is the primary activity within themore » Coupled Model Intercomparison Project Phase 6 (CMIP6) focusing on the ice sheets. Two experiments for the large-scale Greenland ice sheet have been designed to allow intercomparison between participating models of (1) the initial present-day state of the ice sheet and (2) the response in two idealised forward experiments. The forward experiments serve to evaluate the initialisation in terms of model drift (forward run without additional forcing) and in response to a large perturbation (prescribed surface mass balance anomaly); they should not be interpreted as sea-level projections. We present and discuss results that highlight the diversity of data sets, boundary conditions, and initialisation techniques used in the community to generate initial states of the Greenland ice sheet. We find good agreement across the ensemble for the dynamic response to surface mass balance changes in areas where the simulated ice sheets overlap but differences arising from the initial size of the ice sheet. The model drift in the control experiment is reduced for models that participated in earlier intercomparison exercises.« less

  17. Design and results of the ice sheet model initialisation experiments initMIP-Greenland: an ISMIP6 intercomparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goelzer, Heiko; Nowicki, Sophie; Edwards, Tamsin

    Earlier large-scale Greenland ice sheet sea-level projections (e.g. those run during the ice2sea and SeaRISE initiatives) have shown that ice sheet initial conditions have a large effect on the projections and give rise to important uncertainties. Here, the goal of this initMIP-Greenland intercomparison exercise is to compare, evaluate, and improve the initialisation techniques used in the ice sheet modelling community and to estimate the associated uncertainties in modelled mass changes. initMIP-Greenland is the first in a series of ice sheet model intercomparison activities within ISMIP6 (the Ice Sheet Model Intercomparison Project for CMIP6), which is the primary activity within themore » Coupled Model Intercomparison Project Phase 6 (CMIP6) focusing on the ice sheets. Two experiments for the large-scale Greenland ice sheet have been designed to allow intercomparison between participating models of (1) the initial present-day state of the ice sheet and (2) the response in two idealised forward experiments. The forward experiments serve to evaluate the initialisation in terms of model drift (forward run without additional forcing) and in response to a large perturbation (prescribed surface mass balance anomaly); they should not be interpreted as sea-level projections. We present and discuss results that highlight the diversity of data sets, boundary conditions, and initialisation techniques used in the community to generate initial states of the Greenland ice sheet. We find good agreement across the ensemble for the dynamic response to surface mass balance changes in areas where the simulated ice sheets overlap but differences arising from the initial size of the ice sheet. The model drift in the control experiment is reduced for models that participated in earlier intercomparison exercises.« less

  18. Intercomparison of three microwave/infrared high resolution line-by-line radiative transfer codes

    NASA Astrophysics Data System (ADS)

    Schreier, F.; Garcia, S. Gimeno; Milz, M.; Kottayil, A.; Höpfner, M.; von Clarmann, T.; Stiller, G.

    2013-05-01

    An intercomparison of three line-by-line (lbl) codes developed independently for atmospheric sounding - ARTS, GARLIC, and KOPRA - has been performed for a thermal infrared nadir sounding application assuming a HIRS-like (High resolution Infrared Radiation Sounder) setup. Radiances for the HIRS infrared channels and a set of 42 atmospheric profiles from the "Garand dataset" have been computed. Results of this intercomparison and a discussion of reasons of the observed differences are presented.

  19. ISMIP6 - initMIP: Greenland ice sheet model initialisation experiments

    NASA Astrophysics Data System (ADS)

    Goelzer, Heiko; Nowicki, Sophie; Payne, Tony; Larour, Eric; Abe Ouchi, Ayako; Gregory, Jonathan; Lipscomb, William; Seroussi, Helene; Shepherd, Andrew; Edwards, Tamsin

    2016-04-01

    Earlier large-scale Greenland ice sheet sea-level projections e.g. those run during ice2sea and SeaRISE initiatives have shown that ice sheet initialisation can have a large effect on the projections and gives rise to important uncertainties. This intercomparison exercise (initMIP) aims at comparing, evaluating and improving the initialization techniques used in the ice sheet modeling community and to estimate the associated uncertainties. It is the first in a series of ice sheet model intercomparison activities within ISMIP6 (Ice Sheet Model Intercomparison Project for CMIP6). The experiments are conceived for the large-scale Greenland ice sheet and are designed to allow intercomparison between participating models of 1) the initial present-day state of the ice sheet and 2) the response in two schematic forward experiments. The latter experiments serve to evaluate the initialisation in terms of model drift (forward run without any forcing) and response to a large perturbation (prescribed surface mass balance anomaly). We present and discuss first results of the intercomparison and highlight important uncertainties with respect to projections of the Greenland ice sheet sea-level contribution.

  20. An intercomparison of nitric oxide measurement techniques

    NASA Technical Reports Server (NTRS)

    Hoell, J. M., Jr.; Gregory, G. L.; Mcdougal, D. S.; Carroll, M. A.; Mcfarland, M.; Ridley, B. A.; Davis, D. D.; Bradshaw, J.; Rodgers, M. O.; Torres, A. L.

    1985-01-01

    Results from an intercomparison of techniques to measure tropospheric levels of nitric oxide (NO) are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted at Wallops Island, VA, in July 1983. Instruments intercompared included a laser-induced fluorescence system and two chemiluminescence instruments. The intercomparisons were performed with ambient air at NO mixing ratios ranging from 10 to 60 pptv and NO-enriched ambient air at mixing ratios from 20 to 170 pptv. All instruments sampled from a common manifold. The techniques exhibited a high degree of correlation among themselves and with changes in the NO mixing ratio. Agreement among the three techniques was placed at approximately + or - 30 percent. Within this level of agreement, no artifacts or species interferences were identified.

  1. ISMIP6: Ice Sheet Model Intercomparison Project for CMIP6

    NASA Technical Reports Server (NTRS)

    Nowicki, S.

    2015-01-01

    ISMIP6 (Ice Sheet Model Intercomparison Project for CMIP6) targets the Cryosphere in a Changing Climate and the Future Sea Level Grand Challenges of the WCRP (World Climate Research Program). Primary goal is to provide future sea level contribution from the Greenland and Antarctic ice sheets, along with associated uncertainty. Secondary goal is to investigate feedback due to dynamic ice sheet models. Experiment design uses and augment the existing CMIP6 (Coupled Model Intercomparison Project Phase 6) DECK (Diagnosis, Evaluation, and Characterization of Klima) experiments. Additonal MIP (Model Intercomparison Project)- specific experiments will be designed for ISM (Ice Sheet Model). Effort builds on the Ice2sea, SeaRISE (Sea-level Response to Ice Sheet Evolution) and COMBINE (Comprehensive Modelling of the Earth System for Better Climate Prediction and Projection) efforts.

  2. MMAB Sea Ice Forecast Page

    Science.gov Websites

    verification statistics Grumbine, R. W., Virtual Floe Ice Drift Forecast Model Intercomparison, Weather and Forecasting, 13, 886-890, 1998. MMAB Note: Virtual Floe Ice Drift Forecast Model Intercomparison 1996 pdf ~47

  3. Results of the Greenland Ice Sheet Model Initialisation Experiments ISMIP6 - initMIP-Greenland

    NASA Astrophysics Data System (ADS)

    Goelzer, H.; Nowicki, S.; Edwards, T.; Beckley, M.; Abe-Ouchi, A.; Aschwanden, A.; Calov, R.; Gagliardini, O.; Gillet-chaulet, F.; Golledge, N. R.; Gregory, J. M.; Greve, R.; Humbert, A.; Huybrechts, P.; Larour, E. Y.; Lipscomb, W. H.; Le ´h, S.; Lee, V.; Kennedy, J. H.; Pattyn, F.; Payne, A. J.; Rodehacke, C. B.; Rückamp, M.; Saito, F.; Schlegel, N.; Seroussi, H. L.; Shepherd, A.; Sun, S.; Vandewal, R.; Ziemen, F. A.

    2016-12-01

    Earlier large-scale Greenland ice sheet sea-level projections e.g. those run during ice2sea and SeaRISE initiatives have shown that ice sheet initialisation can have a large effect on the projections and gives rise to important uncertainties. The goal of this intercomparison exercise (initMIP-Greenland) is to compare, evaluate and improve the initialization techniques used in the ice sheet modeling community and to estimate the associated uncertainties. It is the first in a series of ice sheet model intercomparison activities within ISMIP6 (Ice Sheet Model Intercomparison Project for CMIP6). Two experiments for the large-scale Greenland ice sheet have been designed to allow intercomparison between participating models of 1) the initial present-day state of the ice sheet and 2) the response in two schematic forward experiments. The forward experiments serve to evaluate the initialisation in terms of model drift (forward run without any forcing) and response to a large perturbation (prescribed surface mass balance anomaly). We present and discuss final results of the intercomparison and highlight important uncertainties with respect to projections of the Greenland ice sheet sea-level contribution.

  4. Satellite Derived Volcanic Ash Product Inter-Comparison in Support to SCOPE-Nowcasting

    NASA Astrophysics Data System (ADS)

    Siddans, Richard; Thomas, Gareth; Pavolonis, Mike; Bojinski, Stephan

    2016-04-01

    In support of aeronautical meteorological services, WMO organized a satellite-based volcanic ash retrieval algorithm inter-comparison activity, to improve the consistency of quantitative volcanic ash products from satellites, under the Sustained, Coordinated Processing of Environmental Satellite Data for Nowcasting (SCOPEe Nowcasting) initiative (http:/ jwww.wmo.int/pagesjprogjsatjscopee nowcasting_en.php). The aims of the intercomparison were as follows: 1. Select cases (Sarychev Peak 2009, Eyjafyallajökull 2010, Grimsvötn 2011, Puyehue-Cordón Caulle 2011, Kirishimayama 2011, Kelut 2014), and quantify the differences between satellite-derived volcanic ash cloud properties derived from different techniques and sensors; 2. Establish a basic validation protocol for satellite-derived volcanic ash cloud properties; 3. Document the strengths and weaknesses of different remote sensing approaches as a function of satellite sensor; 4. Standardize the units and quality flags associated with volcanic cloud geophysical parameters; 5. Provide recommendations to Volcanic Ash Advisory Centers (VAACs) and other users on how to best to utilize quantitative satellite products in operations; 6. Create a "road map" for future volcanic ash related scientific developments and inter-comparison/validation activities that can also be applied to SO2 clouds and emergent volcanic clouds. Volcanic ash satellite remote sensing experts from operational and research organizations were encouraged to participate in the inter-comparison activity, to establish the plans for the inter-comparison and to submit data sets. RAL was contracted by EUMETSAT to perform a systematic inter-comparison of all submitted datasets and results were reported at the WMO International Volcanic Ash Inter-comparison Meeting to held on 29 June - 2 July 2015 in Madison, WI, USA (http:/ /cimss.ssec.wisc.edujmeetings/vol_ash14). 26 different data sets were submitted, from a range of passive imagers and spectrometers and these were inter-compared against each other and against validation data such as CALIPSO lidar, ground-based lidar and aircraft observations. Results of the comparison exercise will be presented together with the conclusions and recommendations arising from the activity.

  5. Assessing agricultural risks of climate change in the 21st century in a global gridded crop model intercomparison

    PubMed Central

    Rosenzweig, Cynthia; Elliott, Joshua; Deryng, Delphine; Ruane, Alex C.; Müller, Christoph; Arneth, Almut; Boote, Kenneth J.; Folberth, Christian; Glotter, Michael; Khabarov, Nikolay; Neumann, Kathleen; Piontek, Franziska; Pugh, Thomas A. M.; Schmid, Erwin; Stehfest, Elke; Yang, Hong; Jones, James W.

    2014-01-01

    Here we present the results from an intercomparison of multiple global gridded crop models (GGCMs) within the framework of the Agricultural Model Intercomparison and Improvement Project and the Inter-Sectoral Impacts Model Intercomparison Project. Results indicate strong negative effects of climate change, especially at higher levels of warming and at low latitudes; models that include explicit nitrogen stress project more severe impacts. Across seven GGCMs, five global climate models, and four representative concentration pathways, model agreement on direction of yield changes is found in many major agricultural regions at both low and high latitudes; however, reducing uncertainty in sign of response in mid-latitude regions remains a challenge. Uncertainties related to the representation of carbon dioxide, nitrogen, and high temperature effects demonstrated here show that further research is urgently needed to better understand effects of climate change on agricultural production and to devise targeted adaptation strategies. PMID:24344314

  6. Assessing Agricultural Risks of Climate Change in the 21st Century in a Global Gridded Crop Model Intercomparison

    NASA Technical Reports Server (NTRS)

    Rosenzweig, Cynthia E.; Elliott, Joshua; Deryng, Delphine; Ruane, Alex C.; Mueller, Christoph; Arneth, Almut; Boote, Kenneth J.; Folberth, Christian; Glotter, Michael; Khabarov, Nikolay

    2014-01-01

    Here we present the results from an intercomparison of multiple global gridded crop models (GGCMs) within the framework of the Agricultural Model Intercomparison and Improvement Project and the Inter-Sectoral Impacts Model Intercomparison Project. Results indicate strong negative effects of climate change, especially at higher levels of warming and at low latitudes; models that include explicit nitrogen stress project more severe impacts. Across seven GGCMs, five global climate models, and four representative concentration pathways, model agreement on direction of yield changes is found in many major agricultural regions at both low and high latitudes; however, reducing uncertainty in sign of response in mid-latitude regions remains a challenge. Uncertainties related to the representation of carbon dioxide, nitrogen, and high temperature effects demonstrated here show that further research is urgently needed to better understand effects of climate change on agricultural production and to devise targeted adaptation strategies.

  7. International NMR-based Environmental Metabolomics Intercomparison Exercise

    EPA Science Inventory

    Several fundamental requirements must be met so that NMR-based metabolomics and the related technique of metabonomics can be formally adopted into environmental monitoring and chemical risk assessment. Here we report an intercomparison exercise which has evaluated the effectivene...

  8. PM 2.5 ORGANIC SPECIATION INTERCOMPARISON RESULTS

    EPA Science Inventory

    This abstract describes a poster on results to a laboratory intercomparison of organic aerosol speciation analysis to be presented at the 2006 International Aerosol Conference sponsored by the American Association for Aerosol Research in St. Paul, Minnesota on September 10-15. T...

  9. Total ozone measurement: Intercomparison of prototype New Zealand filter instrument and Dobson spectrophotometer

    NASA Technical Reports Server (NTRS)

    Basher, R. E.

    1978-01-01

    A five month intercomparison showed that the total ozone amounts of a prototype narrowband interference filter instrument were 7% less than those of a Dobson instrument for an ozone range of 0.300 to 0.500 atm cm and for airmasses less than two. The 7% bias was within the intercomparison calibration uncertainty. An airmass dependence in the Dobson instrument made the bias relationship airmass-dependent but the filter instrument's ozone values were generally constant to 2% up to an airmass of four. Long term drift in the bias was negligible.

  10. The Inter-Sectoral Impact Model Intercomparison Project (ISI–MIP): Project framework

    PubMed Central

    Warszawski, Lila; Frieler, Katja; Huber, Veronika; Piontek, Franziska; Serdeczny, Olivia; Schewe, Jacob

    2014-01-01

    The Inter-Sectoral Impact Model Intercomparison Project offers a framework to compare climate impact projections in different sectors and at different scales. Consistent climate and socio-economic input data provide the basis for a cross-sectoral integration of impact projections. The project is designed to enable quantitative synthesis of climate change impacts at different levels of global warming. This report briefly outlines the objectives and framework of the first, fast-tracked phase of Inter-Sectoral Impact Model Intercomparison Project, based on global impact models, and provides an overview of the participating models, input data, and scenario set-up. PMID:24344316

  11. Fabrication and characterization of optical super-smooth surfaces

    NASA Astrophysics Data System (ADS)

    Schmitt, Dirk-Roger; Kratz, Frank; Ringel, Gabriele A.; Mangelsdorf, Juergen; Creuzet, Francois; Garratt, John D.

    1995-08-01

    Intercomparison roughness measurements have been carried out at supersmooth artefacts fabricated from BK7, fused silica, and Zerodur. The surface parameters were determined using a special prototype of the mechanical profiler Nanostep (Rank Taylor Hobson), the Optical Heterodyne Profiler Z5500 (Zygo), and an Atomic Force Microscope (Park Scientific) with an improved acquisition technique. The intercomparison was performed after the range of collected spatial wavelength for each instrument was adjusted using digital filtering techniques. It is demonstrated for different roughness ranges that are applied superpolishing techniques yield supersmooth artefacts which can be used for more intercomparisons.

  12. Water vapour inter-comparison effort in the framework of the hydrological cycle in the mediterranean experiment - special observation period (hymex-sop1)

    NASA Astrophysics Data System (ADS)

    Summa, Donato; Di Girolamo, Paolo; Flamant, Cyrille; De Rosa, Benedetto; Cacciani, Marco; Stelitano, Dario

    2018-04-01

    Accurate measurements of the vertical profiles of water vapour are of paramount importance for most key areas of atmospheric sciences. A comprehensive inter-comparison between different remote sensing and in-situ sensors has been carried out in the frame work of the first Special Observing Period of the Hydrological cycle in the Mediterranean Experiment for the purpose of obtaining accurate error estimates for these sensors. The inter-comparison involves a ground-based Raman lidar (BASIL), an airborne DIAL (LEANDRE2), a microwave radiometer, radiosondes and aircraft in-situ sensors.

  13. Evaluation of the annual Canadian biodosimetry network intercomparisons

    PubMed Central

    Wilkins, Ruth C.; Beaton-Green, Lindsay A.; Lachapelle, Sylvie; Kutzner, Barbara C.; Ferrarotto, Catherine; Chauhan, Vinita; Marro, Leonora; Livingston, Gordon K.; Boulay Greene, Hillary; Flegal, Farrah N.

    2015-01-01

    Abstract Purpose: To evaluate the importance of annual intercomparisons for maintaining the capacity and capabilities of a well-established biodosimetry network in conjunction with assessing efficient and effective analysis methods for emergency response. Materials and methods: Annual intercomparisons were conducted between laboratories in the Canadian National Biological Dosimetry Response Plan. Intercomparisons were performed over a six-year period and comprised of the shipment of 10–12 irradiated, blinded blood samples for analysis by each of the participating laboratories. Dose estimates were determined by each laboratory using the dicentric chromosome assay (conventional and QuickScan scoring) and where possible the cytokinesis block micronucleus (CBMN) assay. Dose estimates were returned to the lead laboratory for evaluation and comparison. Results: Individual laboratories performed comparably from year to year with only slight fluctuations in performance. Dose estimates using the dicentric chromosome assay were accurate about 80% of the time and the QuickScan method for scoring the dicentric chromosome assay was proven to reduce the time of analysis without having a significant effect on the dose estimates. Although analysis with the CBMN assay was comparable to QuickScan scoring with respect to speed, the accuracy of the dose estimates was greatly reduced. Conclusions: Annual intercomparisons are necessary to maintain a network of laboratories for emergency response biodosimetry as they evoke confidence in their capabilities. PMID:25670072

  14. INTERCOMPARISON STUDY OF ATMOSPHERIC MERCURY MODELS: 1. COMPARISON OF MODELS WITH SHORT-TERM MEASUREMENTS

    EPA Science Inventory

    Five regional scale models with a horizontal domain covering the European continent and its surrounding seas, one hemispheric and one global scale model participated in an atmospheric mercury modelling intercomparison study. Model-predicted concentrations in ambient air were comp...

  15. Estimating near-road pollutant dispersion: a model inter-comparison

    EPA Science Inventory

    A model inter-comparison study to assess the abilities of steady-state Gaussian dispersion models to capture near-road pollutant dispersion has been carried out with four models (AERMOD, run with both the area-source and volume-source options to represent roadways, CALINE, versio...

  16. International intercomparison of measuring instruments for radon/thoron gas and radon short-lived daughter products in the NRPI Prague.

    PubMed

    Jílek, K; Hýža, M; Kotík, L; Thomas, J; Tomášek, L

    2014-07-01

    During the 7th European Conference on Protection Against Radon at Home and at Work held in the autumn of 2013 in Prague, the second intercomparison of measuring instruments for radon and its short-lived decay products and the first intercomparison of radon/thoron gas discriminative passive detectors in mix field of radon/thoron were organised by and held at the Natural Radiation Division of the National Radiation Protection Institute (NRPI) in Prague. In total, 14 laboratories from 11 different countries took part in the 2013 NRPI intercomparison. They submitted both continuous monitors for the measurement of radon gas and equivalent equilibrium radon concentration in a big NRPI chamber (48 m3) and sets of passive detectors including radon/thoron discriminative for the measurement of radon gas in the big chamber and thoron gas in a small thoron chamber (150 dm3). © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. An intercomparison of carbon monoxide, nitric oxide, and hydroxyl measurement techniques - Overview of results

    NASA Technical Reports Server (NTRS)

    Hoell, J. M.; Gregory, G. L.; Carroll, M. A.; Mcfarland, M.; Ridley, B. A.; Davis, D. D.; Bradshaw, J.; Rodgers, M. O.; Torres, A. L.; Condon, E. P.

    1984-01-01

    Results from an intercomparison of methods to measure carbon monoxide (CO), nitric oxide (NO), and the hydroxyl radical (OH) are discussed. The intercomparison was conducted at Wallops Island, Virginia, in July 1983 and included a laser differential absorption and three grab sample/gas chromatograph methods for CO, a laser-induced fluorescence (LIF) and two chemiluminescence methods for NO, and two LIF methods and a radiocarbon tracer method for OH. The intercomparison was conducted as a field measurement program involving ambient measurements of CO (150-300 ppbv) and NO (10-180 pptv) from a common manifold with controlled injection of CO in incremental steps from 20 to 500 ppbv and NO in steps from 10 to 220 pptv. Only ambient measurements of OH were made. The agreement between the techniques was on the order of 14 percent for CO and 17 percent for NO. Hardware difficulties during the OH tests resulted in a data base with insufficient data and uncertanties too large to permit a meaningful intercomposition.

  18. Operational overview of the NASA GTE/CITE 3 airborne instrument intercomparisons for sulfur dioxide, hydrogen sulfide, carbonyl sulfide, dimethyl sulfide, and carbon disulfide

    NASA Technical Reports Server (NTRS)

    Hoell, James M., Jr.; Davis, Douglas D.; Gregory, Gerald L.; Mcneal, Robert J.; Bendura, Richard J.; Drewry, Joseph W.; Barrick, John D.; Kirchhoff, Volker W. J. H.; Motta, Adauto G.; Navarro, Roger L.

    1993-01-01

    This paper reports the overall experimental design and gives a brief overview of results from the third airborne Chemical Instrumentation Test and Evaluation (CITE 3) mission conducted as part of the National Aeronautics and Space Administration's Global Tropospheric Experiment. The primary objective of CITE 3 was to evaluate the capability of instrumentation for airborne measurements of ambient concentrations of SO2, H2S, CS, dimethyl sulfide, and carbonyl sulfide. Ancillary measurements augmented the intercomparison data in order to address the secondary objective of CITE 3 which was to address specific issues related to the budget and photochemistry of tropospheric sulfur species. The CITE 3 mission was conducted on NASA's Wallops Flight Center Electra aircraft and included a ground-based intercomparison of sulfur standards and intercomparison/sulfur science flights conducted from the NASA Wallops Flight Facility, Wallops Island, Virginia, followed by flights from Natal, Brazil. Including the transit flights, CITE 3 included 16 flights encompassing approximately 96 flight hours.

  19. A soil sampling intercomparison exercise for the ALMERA network.

    PubMed

    Belli, Maria; de Zorzi, Paolo; Sansone, Umberto; Shakhashiro, Abduhlghani; Gondin da Fonseca, Adelaide; Trinkl, Alexander; Benesch, Thomas

    2009-11-01

    Soil sampling and analysis for radionuclides after an accidental or routine release is a key factor for the dose calculation to members of the public, and for the establishment of possible countermeasures. The IAEA organized for selected laboratories of the ALMERA (Analytical Laboratories for the Measurement of Environmental Radioactivity) network a Soil Sampling Intercomparison Exercise (IAEA/SIE/01) with the objective of comparing soil sampling procedures used by different laboratories. The ALMERA network is a world-wide network of analytical laboratories located in IAEA member states capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. Ten ALMERA laboratories were selected to participate in the sampling exercise. The soil sampling intercomparison exercise took place in November 2005 in an agricultural area qualified as a "reference site", aimed at assessing the uncertainties associated with soil sampling in agricultural, semi-natural, urban and contaminated environments and suitable for performing sampling intercomparison. In this paper, the laboratories sampling performance were evaluated.

  20. Climate model simulations of the mid-Pliocene: Earth's last great interval of global warmth

    USGS Publications Warehouse

    Dolan, A.M.; Haywood, A.M.; Dowsett, H.J.

    2012-01-01

    Pliocene Model Intercomparison Project Workshop; Reston, Virginia, 2–4 August 2011 The Pliocene Model Intercomparison Project (PlioMIP), supported by the U.S. Geological Survey's (USGS) Pliocene Research, Interpretation and Synoptic Mapping (PRISM) project and Powell Center, is an integral part of a third iteration of the Paleoclimate Modelling Intercomparison Project (PMIP3). PlioMIP's aim is to systematically compare structurally different climate models. This is done in the context of the mid-Pliocene (~3.3–3.0 million years ago), a geological interval when the global annual mean temperature was similar to predictions for the next century.

  1. Radon intercomparisons at EML, January 1983 and February 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisenne, I.M.; George, A.C.; Keller, H.W.

    1985-02-01

    This report summarizes the results of two radon measurement intercomparison exercises held at the Environmental Measurements Laboratory (EML) in January 1983 and February 1984. Nineteen organizations, including five US federal facilities, one national laboratory, two state laboratories, six universities, three private sector laboratories and two non-US facilities participated in these exercises. The results indicate good agreement among the participants at /sup 222/Rn concentration levels of 50 and 80 pCi.L/sup -1/. Improvements in the EML calibration facilities, and the participation of two US laboratories in a Nuclear Energy Agency intercomparison program are also discussed. 8 references, 6 figures, 8 tables.

  2. ARM/GCSS/SPARC TWP-ICE CRM Intercomparison Study

    NASA Technical Reports Server (NTRS)

    Fridlind, Ann; Ackerman, Andrew; Petch, Jon; Field, Paul; Hill, Adrian; McFarquhar, Greg; Xie, Shaocheng; Zhang, Minghua

    2010-01-01

    Specifications are provided for running a cloud-resolving model (CRM) and submitting results in a standardized format for inclusion in a n intercomparison study and archiving for public access. The simulated case study is based on measurements obtained during the 2006 Tropical Warm Pool - International Cloud Experiment (TWP-ICE) led by the U. S. department of Energy Atmospheric Radiation Measurement (ARM) program. The modeling intercomparison study is based on objectives developed in concert with the Stratospheric Processes And their Role in Climate (SPARC) program and the GEWEX cloud system study (GCSS) program. The Global Energy and Water Cycle Experiment (GEWEX) is a core project of the World Climate Research PRogramme (WCRP).

  3. THE NORTH AMERICAN MERCURY MODEL INTER-COMPARISON STUDY (NAMMIS)

    EPA Science Inventory

    This paper describes the North American Mercury Model Inter-comparison Study (NAMMIS). The NAMMIS is an effort to apply atmospheric Hg models in a tightly constrained testing environment with a focus on North America. With each model using the same input data sets for initial co...

  4. PNNL Results from 2010 CALIBAN Criticality Accident Dosimeter Intercomparison Exercise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, Robin L.; Conrady, Matthew M.

    2011-10-28

    This document reports the results of the Hanford personnel nuclear accident dosimeter (PNAD) and fixed nuclear accident dosimeter (FNAD) during a criticality accident dosimeter intercomparison exercise at the CEA Valduc Center on September 20-23, 2010. Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimeter intercomparison exercise at the Commissariat a Energie Atomique (CEA) Valduc Center near Dijon, France on September 20-23, 2010. The intercomparison exercise was funded by the U.S. Department of Energy, Nuclear Criticality Safety Program, with Lawrence Livermore National Laboratory as the lead Laboratory. PNNL was one of six invited DOE Laboratory participants. The other participatingmore » Laboratories were: Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Savannah River Site (SRS), the Y-12 National Security Complex at Oak Ridge, and Sandia National Laboratory (SNL). The goals of PNNL's participation in the intercomparison exercise were to test and validate the procedures and algorithm currently used for the Hanford personnel nuclear accident dosimeters (PNADs) on the metallic reactor, CALIBAN, to test exposures to PNADs from the side and from behind a phantom, and to test PNADs that were taken from a historical batch of Hanford PNADs that had varying degrees of degradation of the bare indium foil. Similar testing of the PNADs was done on the Valduc SILENE test reactor in 2009 (Hill and Conrady, 2010). The CALIBAN results are reported here.« less

  5. SimilarityExplorer: A visual inter-comparison tool for multifaceted climate data

    Treesearch

    J. Poco; A. Dasgupta; Y. Wei; W. Hargrove; C. Schwalm; R. Cook; E. Bertini; C. Silva

    2014-01-01

    Inter-comparison and similarity analysis to gauge consensus among multiple simulation models is a critical visualization problem for understanding climate change patterns. Climate models, specifically, Terrestrial Biosphere Models (TBM) represent time and space variable ecosystem processes, for example, simulations of photosynthesis and respiration, using algorithms...

  6. FIELD INTERCOMPARISON OF SULFATE DRY DEPOSITION MONITORING AND MEASUREMENT METHODS: PRELIMINARY RESULTS

    EPA Science Inventory

    The Illinois State Water Survey hosted a three-week field intercomparison of several sulfate dry deposition measurement techniques during September 81. The site was an 80-acre grass field in a rural area 14 km southwest of Champaign, IL. The vegetation consisted of mixed grasses ...

  7. An Analysis of Simulated Wet Deposition of Mercury from the North American Mercury Model Intercomparison Study

    EPA Science Inventory

    A previous intercomparison of atmospheric mercury models in North America has been extended to compare simulated and observed wet deposition of mercury. Three regional-scale atmospheric mercury models were tested; CMAQ, REMSAD and TEAM. These models were each employed using thr...

  8. METHODS INTERCOMPARISON OF SAMPLERS FOR EPA'S NATIONAL PM 2.5 CHEMICAL SPECIATION NETWORK

    EPA Science Inventory

    The objective of this sampler intercomparison field study is to determine the performance characteristics for the collection of the chemical components of PM2.5 by the chemical speciation monitors developed for the national PM2.5 network relative to each other, to the Federal R...

  9. Solid precipitation measurement intercomparison in Bismarck, North Dakota, from 1988 through 1997

    USGS Publications Warehouse

    Ryberg, Karen R.; Emerson, Douglas G.; Macek-Rowland, Kathleen M.

    2009-01-01

    A solid precipitation measurement intercomparison was recommended by the World Meteorological Organization (WMO) and was initiated after approval by the ninth session of the Commission for Instruments and Methods of Observation. The goal of the intercomparison was to assess national methods of measuring solid precipitation against methods whose accuracy and reliability were known. A field study was started in Bismarck, N. Dak., during the 1988-89 winter as part of the intercomparison. The last official field season of the WMO intercomparison was 1992-93; however, the Bismarck site continued to operate through the winter of 1996-97. Precipitation events at Bismarck were categorized as snow, mixed, or rain on the basis of descriptive notes recorded as part of the solid precipitation intercomparison. The rain events were not further analyzed in this study. Catch ratios (CRs) - the ratio of the precipitation catch at each gage to the true precipitation measurement (the corrected double fence intercomparison reference) - were calculated. Then, regression analysis was used to develop equations that model the snow and mixed precipitation CRs at each gage as functions of wind speed and temperature. Wind speed at the gages, functions of temperature, and upper air conditions (wind speed and air temperature at 700 millibars pressure) were used as possible explanatory variables in the multiple regression analysis done for this study. The CRs were modeled by using multiple regression analysis for the Tretyakov gage, national shielded gage, national unshielded gage, AeroChem gage, national gage with double fence, and national gage with Wyoming windshield. As in earlier studies by the WMO, wind speed and air temperature were found to influence the CR of the Tretyakov gage. However, in this study, the temperature variable represented the average upper air temperature over the duration of the event. The WMO did not use upper air conditions in its analysis. The national shielded and unshielded gages where found to be influenced by functions of wind speed only, as in other studies, but the upper air wind speed was used as an explanatory variable in this study. The AeroChem gage was not used in the WMO intercomparison study for 1987-93. The AeroChem gage had a highly varied CR at Bismarck, and a number of variables related to wind speed and temperature were used in the model for the CR. Despite extensive efforts to find a model for the national gage with double fence, no statistically significant regression model was found at the 0.05 level of statistical significance. The national gage with Wyoming windshield had a CR modeled by temperature and wind speed variables, and the regression relation had the highest coefficient of determination (R2 = 0.572) and adjusted coefficient of multiple determination (R2a = 0.476) of all of the models identified for any gage. Three of the gage CRs evaluated could be compared with those in the WMO intercomparison study for 1987-93. The WMO intercomparison had the advantage of a much larger dataset than this study. However, the data in this study represented a longer time period. Snow precipitation catch is highly varied depending on the equipment used and the weather conditions. Much of the variation is not accounted for in the WMO equations or in the equations developed in this study, particularly for unshielded gages. Extensive attempts at regression analysis were made with the mixed precipitation data, but it was concluded that the sample sizes were not large enough to model the CRs. However, the data could be used to test the WMO intercomparison equations. The mixed precipitation equations for the Tretyakov and national shielded gages are similar to those for snow in that they are more likely to underestimate precipitation when observed amounts were small and overestimate precipitation when observed amounts were relatively large. Mixed precipitation is underestimated by the WMO adjustment and t

  10. The Fifth Calibration/Data Product Validation Panel Meeting

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The minutes and associated documents prepared from presentations and meetings at the Fifth Calibration/Data Product Validation Panel meeting in Boulder, Colorado, April 8 - 10, 1992, are presented. Key issues include (1) statistical characterization of data sets: finding statistics that characterize key attributes of the data sets, and defining ways to characterize the comparisons among data sets; (2) selection of specific intercomparison exercises: selecting characteristic spatial and temporal regions for intercomparisons, and impact of validation exercises on the logistics of current and planned field campaigns and model runs; and (3) preparation of data sets for intercomparisons: characterization of assumptions, transportable data formats, labeling data files, content of data sets, and data storage and distribution (EOSDIS interface).

  11. INTERCOMPARISON STUDY OF ATMOSPHERIC MERCURY MODELS: 2. MODELING RESULTS VS. LONG-TERM OBSERVATIONS AND COMPARISON OF COUNTRY ATMOSPHERIC BALANCES

    EPA Science Inventory

    Five regional scale models with a horizontal domain covering the European continent and its surrounding seas, two hemispheric and one global scale model participated in the atmospheric Hg modelling intercomparison study. The models were compared between each other and with availa...

  12. A Compendium on the NIST Radionuclidic Assays of the Massic Activity of 63Ni and 55Fe Solutions Used for an International Intercomparison of Liquid Scintillation Spectrometry Techniques

    PubMed Central

    Collé, R.; Zimmerman, B. E.

    1997-01-01

    The National Institute of Standards and Technology recently participated in an international measurement intercomparison for 63Ni and 55Fe, which was conducted amongst principal national radionuclidic metrology laboratories. The intercomparison was sponsored by EUROMET, and was primarily intended to evaluate the capabilities of liquid scintillation (LS) spectrometry techniques for standardizing nuclides that decay by low-energy β-emission (like 63Ni) and by low-Z (atomic number) electron capture (like 55Fe). The intercomparison findings exhibit a very good agreement for 63Ni amongst the various participating laboratories, including that for NIST, which suggests that the presently invoked LS methodologies are very capable of providing internationally-compatible standardizations for low-energy β-emitters. The results for 55Fe are in considerably poorer agreement, and demonstrated the existence of several unresolved problems. It has thus become apparent that there is a need for the various international laboratories to conduct rigorous, systematic evaluations of their LS capabilities in assaying radionuclides that decay by low-Z electron capture. PMID:27805141

  13. SECOND LATIN AMERICAN INTERCOMPARISON ON INTERNAL DOSE ASSESSMENT.

    PubMed

    Rojo, A; Puerta, N; Gossio, S; Gómez Parada, I; Cruz Suarez, R; López, E; Medina, C; Lastra Boylan, J; Pinheiro Ramos, M; Mora Ramírez, E; Alves Dos Reis, A; Yánez, H; Rubio, J; Vironneau Janicek, L; Somarriba Vanegas, F; Puerta Ortiz, J; Salas Ramírez, M; López Bejerano, G; da Silva, T; Miri Oliveira, C; Terán, M; Alfaro, M; García, T; Angeles, A; Duré Romero, E; Farias de Lima, F

    2016-09-01

    Internal dosimetry intercomparisons are essential for the verification of applied models and the consistency of results'. To that aim, the First Regional Intercomparison was organised in 2005, and that results led to the Second Regional Intercomparison Exercise in 2013, which was organised in the frame of the RLA 9/066 and coordinated by Autoridad Regulatoria Nuclear of Argentina. Four simulated cases covering intakes of (131)I, (137)Cs and Tritium were proposed. Ninteen centres from thirteen different countries participated in this exercise. This paper analyses the participants' results in this second exercise in order to test their skills and acquired knowledge, particularly in the application of the IDEAS Guidelines. It is important to highlight the increased number of countries that participated in this exercise compared with the first one and, furthermore, the improvement in the overall performance. The impact of the International Atomic Energy Agency (IAEA) Projects since 2003 has led to a significant enhancement of internal dosimetry capabilities that strengthen the radiation protection of workers. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. 1993 Intercomparison of Photometric Units Maintained at NIST (USA) and PTB (Germany)

    PubMed Central

    Ohno, Yoshihiro; Sauter, Georg

    1995-01-01

    A bilateral intercomparison of photometric units between NIST, USA and PTB, Germany has been conducted to update the knowledge of the relationship between the photometric units disseminated in each country. The luminous intensity unit (cd) and the luminous flux unit (lm) maintained at both laboratories are compared by circulating transfer standard lamps. Also, the photometric responsivity sv is compared by circulating a V(λ)-corrected detector with a built-in current-to-voltage converter. The results show that the difference of luminous intensity unit between NIST and PTB, (PTB-NIST)/NIST, is 0.2 % with a relative expanded uncertainty (coverage factor k = 2) of 0.24 %. The difference is reduced significantly from that at the 1985 CCPR intercomparison (0.9 %). The difference in luminous flux unit, (PTB – NIST)/NIST, is found to be 1.5 % with a relative expanded uncertainty (coverage factor k =2) of 0.15 %. The difference remained nearly the same as that at the 1985 intercomparison (1.6 %). These results agree with what is predicted from the history of maintaining the units at each laboratory. PMID:29151737

  15. Reproducibility in cyclostratigraphy: initiating an intercomparison project

    NASA Astrophysics Data System (ADS)

    Sinnesael, Matthias; De Vleeschouwer, David; Zeeden, Christian; Claeys, Philippe

    2017-04-01

    The study of astronomical climate forcing and the application of cyclostratigraphy have experienced a spectacular growth over the last decades. In the field of cyclostratigraphy a broad range in methodological approaches exist. However, comparative study between the different approaches is lacking. Different cases demand different approaches, but with the growing importance of the field, questions arise about reproducibility, uncertainties and standardization of results. The radioisotopic dating community, in particular, has done far-reaching efforts to improve reproducibility and intercomparison of radioisotopic dates and their errors. To satisfy this need in cyclostratigraphy, we initiate a comparable framework for the community. The aims are to investigate and quantify reproducibility of, and uncertainties related to cyclostratigraphic studies and to provide a platform to discuss the merits and pitfalls of different methodologies, and their applicabilities. With this poster, we ask the feedback from the community on how to design this comparative framework in a useful, meaningful and productive manner. In parallel, we would like to discuss how reproducibility should be tested and what uncertainties should stand for in cyclostratigraphy. On the other hand, we intend to trigger interest for a cyclostratigraphic intercomparison project. This intercomparison project would imply the analysis of artificial and genuine geological records by individual researchers. All participants would be free to determine their method of choice. However, a handful of criterions will be required for an outcome to be comparable. The different results would be compared (e.g. during a workshop or a special session), and the lessons learned from the comparison could potentially be reported in a review paper. The aim of an intercomparison project is not to rank the different methods according to their merits, but to get insight into which specific methods are most suitable for which specific problems, and obtain more information on different sources of uncertainty. As this intercomparison project should be supported by the broader cyclostratigraphic community, we open the floor for suggestions, ideas and practical remarks.

  16. Spectroradiometer Intercomparison and Impact on Characterizing Photovoltaic Device Performance: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habte, A.; Andreas, A.; Ottoson, L.

    2014-11-01

    Indoor and outdoor testing of photovoltaic (PV) device performance requires the use of solar simulators and natural solar radiation, respectively. This performance characterization requires accurate knowledge of spectral irradiance distribution that is incident on the devices. Spectroradiometers are used to measure the spectral distribution of solar simulators and solar radiation. On September 17, 2013, a global spectral irradiance intercomparison using spectroradiometers was organized by the Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL). This paper presents highlights of the results of this first intercomparison, which will help to decrease systematic inter-laboratory differences in the measurements ofmore » the outputs or efficiencies of PV devices and harmonize laboratory experimental procedures.« less

  17. Magnetic iron oxide and manganese-doped iron oxide nanoparticles for the collection of alpha-emitting radionuclides from aqueous solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Hara, Matthew J.; Carter, Jennifer C.; Warner, Cynthia L.

    Magnetic nanoparticles are well known to possess chemically active surfaces and high surface areas that can be employed to extract a range of ions from aqueous solutions. Additionally, their paramagnetic property provides a convenient means for bulk collection of the material from solution after the targeted ions have been adsorbed. Herein, two nanoscale amphoteric metal oxides, each possessing useful magnetic attributes, were evaluated for their ability to collect both naturally occurring radioactive isotopes (polonium (Po), radium (Ra), and uranium (U)) as well as the transuranic element americium (Am) from a suite of naturally occurring aqueous matrices. The nanomaterials include commerciallymore » available paramagnetic magnetite (Fe3O4) and magnetite that was modified to incorporate manganese (Mn) into the crystal structure. The chemical stability of these nanomaterials was evaluated in Hanford Site, WA ground water between the natural pH (~8) and pH 1 (acidified with HCl). Whereas the magnetite was observed to have good stability over the pH range, the Mn-doped material was observed to leach Mn at low pH. The materials were evaluated in parallel to characterize their uptake performance of the aforementioned alpha-emitting radionuclide spikes from Hanford Site ground water across a range of pH (from ~8 down to 2). In addition, radiotracer uptake experiments were performed on Columbia River water, seawater, and human urine at their natural pH and at pH 2. Despite the observed leaching of Mn from the Mn-doped nanomaterial in the lower pH range, it exhibited generally superior analyte extraction performance compared to the magnetite, and analyte uptake was observed across a broader pH range. The uptake behavior of the various radiotracers on these two materials at different pH levels can generally be explained by the amphoteric nature of the nanoparticle surfaces. Finally, the rate of sorption of the radiotracers on the two materials in unacidified groundwater was evaluated. The uptake curves generally indicate that equilibrium is obtained within a few minutes, which is attributed to the high surface areas of the nanomaterials and the high level of dispersion in the liquids. Overall, the results indicate that these nanomaterials may have the potential to be employed for a range of applications to extract radionuclides from aqueous solutions. These applications may include analytical chemistry, waste water treatment and remediation, mining, and in vitro radiobioassay.« less

  18. BRDF Characterization and Calibration Inter-Comparison between Terra MODIS, Aqua MODIS, and S-NPP VIIRS

    NASA Technical Reports Server (NTRS)

    Chang, Tiejun; Xiong, Xiaoxiong (Jack); Angal, Amit; Wu, Aisheng

    2016-01-01

    The inter-comparison of reflective solar bands (RSB) between Terra MODIS, Aqua MODIS, and SNPP VIIRS is very important for assessment of each instrument's calibration and to identify calibration improvements. One of the limitations of using their ground observations for the assessment is a lack of the simultaneous nadir overpasses (SNOs) over selected pseudo-invariant targets. In addition, their measurements over a selected Earth view target have significant difference in solar and view angles, and these differences magnify the effects of Bidirectional Reflectance Distribution Function (BRDF). In this work, an inter-comparison technique using a semi-empirical BRDF model is developed for reflectance correction. BRDF characterization requires a broad coverage of solar and view angles in the measurements over selected pseudo-invariant targets. Reflectance measurements over Libya 1, 2, and 4 desert sites from both the Aqua and Terra MODIS are regressed to a BRDF model with an adjustable coefficient accounting for the calibration difference between the two instruments. The BRDF coefficients for three desert sites for MODIS bands 1 to 9 are derived and the wavelength dependencies are presented. The analysis and inter-comparison are for MODIS bands 1 to 9 and VIIRS moderate resolution radiometric bands (M bands) M1, M2, M4, M5, M7, M8, M10 and imaging bands (I bands) I1-I3. Results show that the ratios from different sites are in good agreement. The ratios between Terra and Aqua MODIS from year 2003 to 2014 are presented. The inter-comparison between MODIS and VIIRS are analyzed for year 2014.

  19. A Methodological Inter-Comparison of Gridded Meteorological Products

    NASA Astrophysics Data System (ADS)

    Newman, A. J.; Clark, M. P.; Longman, R. J.; Giambelluca, T. W.; Arnold, J.

    2017-12-01

    Here we present a gridded meteorology inter-comparison using the state of Hawaíi as a testbed. This inter-comparison is motivated by two general goals: 1) the broad user community of gridded observation based meteorological fields should be aware of inter-product differences and the reasons they exist, which allows users to make informed choices on product selection to best meet their specific application(s); 2) we want to demonstrate the utility of inter-comparisons to meet the first goal, yet highlight that they are limited to mostly generic statements regarding attribution of differences that limits our understanding of these complex algorithms and obscures future research directions. Hawaíi is a useful testbed because it is a meteorologically complex region with well-known spatial features that are tied to specific physical processes (e.g. the trade wind inversion). From a practical standpoint, there are now several monthly climatological and daily precipitation and temperature datasets available that are being used for impact modeling. General conclusions that have emerged are: 1) differences in input station data significantly influence product differences; 2) prediction of precipitation occurrence is crucial across multiple metrics; 3) derived temperature statistics (e.g. diurnal temperature range) may have large spatial differences across products; and 4) attribution of differences to methodological choices is difficult and may limit the outcomes of these inter-comparisons, particularly from a development viewpoint. Thus, we want to continue to move the community towards frameworks that allow for multiple options throughout the product generation chain and allow for more systematic testing.

  20. Assessing the Application of Cloud-Shadow Atmospheric Correction Algorithm on HICO

    DTIC Science & Technology

    2014-05-01

    multiple times and intercompare the results to assess variability in the retrieved reflectance spectra. Retrieved chlorophyll values from this...intercomparison are similar and also agree well with the In situ chlorophyll measurements. 15. SUBJECT TERMS Atmospheric correction, cloud-shadow...reflectance spectra. Re- trieved chlorophyll values from this intercomparison are similar and also agree well with the in situ chlorophyll measurements

  1. Development of phantom and methodology for 3D and 4D dose intercomparisons for advanced lung radiotherapy

    NASA Astrophysics Data System (ADS)

    Caloz, Misael; Kafrouni, Marilyne; Leturgie, Quentin; Corde, Stéphanie; Downes, Simon; Lehmann, Joerg; Thwaites, David

    2015-01-01

    There are few reported intercomparisons or audits of combinations of advanced radiotherapy methods, particularly for 4D treatments. As part of an evaluation of the implementation of advanced radiotherapy technology, a phantom and associated methods, initially developed for in-house commissioning and QA of 4D lung treatments, has been developed further with the aim of using it for end-to-end dose intercomparison of 4D treatment planning and delivery. The respiratory thorax phantom can house moving inserts with variable speed (breathing rate) and motion amplitude. In one set-up mode it contains a small ion chamber for point dose measurements, or alternatively it can hold strips of radiochromic film to measure dose distributions. Initial pilot and feasibility measurements have been carried out in one hospital to thoroughly test the methods and procedures before using it more widely across a range of hospitals and treatment systems. Overall, the results show good agreement between measured and calculated doses and distributions, supporting the use of the phantom and methodology for multi-centre intercomparisons. However, before wider use, refinements of the method and analysis are currently underway particularly for the film measurements.

  2. A Comparison of Aircraft and Ground-Based Measurements at Mauna Loa Observatory, Hawaii, During GTE PEM-West and MLOPEX 2

    NASA Technical Reports Server (NTRS)

    Atlas, E.; Ridley, B.; Walega, J.; Greenberg, J.; Kok, G.; Staffelbach, T.; Schauffler, S.; Lind, J.; Huebler, G.; Norton, R.

    1996-01-01

    During October 19-20, 1991, one flight of the NASA Global Tropospheric Experiment (GTE) Pacific Exploratory Mission (PEM-West A) mission was conducted near Hawaii as an intercomparison with ground-based measurements of the Mauna Loa Observatory Photochemistry Experiment (MLOPEX 2) and the NOAA Climate Modeling and Diagnostics Laboratory (CMDL). Ozone, reactive nitrogen species, peroxides, hydrocarbons, and halogenated hydrocarbons were measured by investigators aboard the DC-8 aircraft and at the ground site. Lidar cross sections of ozone revealed a complex air mass structure near the island of Hawaii which was evidenced by large variation in some trace gas mixing ratios. This variation limited the time and spatial scales for direct measurement intercomparisons. Where differences occurred between measurements in the same air masses, the intercomparison suggested that biases for some trace gases was due to different calibration scales or, in some cases, instrumental or sampling biases. Relatively large uncertainties were associated with those trace gases present in the low parts per trillion by volume range. Trace gas correlations were used to expand the scope of the intercomparison to identify consistent trends between the different data sets.

  3. A novel method for rapid in vitro radiobioassay

    NASA Astrophysics Data System (ADS)

    Crawford, Evan Bogert

    Rapid and accurate analysis of internal human exposure to radionuclides is essential to the effective triage and treatment of citizens who have possibly been exposed to radioactive materials in the environment. The two most likely scenarios in which a large number of citizens would be exposed are the detonation of a radiation dispersal device (RDD, "dirty bomb") or the accidental release of an isotope from an industrial source such as a radioisotopic thermal generator (RTG). In the event of the release and dispersion of radioactive materials into the environment in a large city, the entire population of the city -- including all commuting workers and tourists -- would have to be rapidly tested, both to satisfy the psychological needs of the citizens who were exposed to the mental trauma of a possible radiation dose, and to satisfy the immediate medical needs of those who received the highest doses and greatest levels of internal contamination -- those who would best benefit from rapid, intensive medical care. In this research a prototype rapid screening method to screen urine samples for the presence of up to five isotopes, both individually and in a mixture, has been developed. The isotopes used to develop this method are Co-60, Sr-90, Cs-137, Pu-238, and Am-241. This method avoids time-intensive chemical separations via the preparation and counting of a single sample on multiple detectors, and analyzing the spectra for isotope-specific markers. A rapid liquid-liquid separation using an organic extractive scintillator can be used to help quantify the activity of the alpha-emitting isotopes. The method provides quantifiable results in less than five minutes for the activity of beta/gamma-emitting isotopes when present in the sample at the intervention level as defined by the Centers for Disease Control and Prevention (CDC), and quantifiable results for the activity levels of alpha-emitting isotopes present at their respective intervention levels in approximately 30 minutes of sample preparation and counting time. Radiation detector spectra -- e.g. those from high-purity germanium (HPGe) gamma detectors and liquid scintillation detectors -- which contain decay signals from multiple isotopes often have overlapping signals: the counts from one isotope's decay can appear in energy channels associated with another isotope's decay, complicating the calculation of each isotope's activity. The uncertainties associated with analyzing these spectra have been traced in order to determine the effects of one isotope's count rate on the sensitivity and uncertainty associated with each other isotope. The method that was developed takes advantage of activated carbon filtration to eliminate quenching effects and to make the liquid scintillation spectra from different urine samples comparable. The method uses pulse-shape analysis to reduce the interference from beta emitters in the liquid scintillation spectrum and improve the minimum detectable activity (MDA) and minimum quantifiable activity (MQA) for alpha emitters. The method uses an HPGe detector to quantify the activity of gamma emitters, and subtract their isotopes' contributions to the liquid scintillation spectra via a calibration factor, such that the pure beta and pure alpha emitters can be identified and quantified from the resulting liquid scintillation spectra. Finally, the method optionally uses extractive scintillators to rapidly separate the alpha emitters from the beta emitters when the activity from the beta emitters is too great to detect or quantify the activity from the alpha emitters without such a separation. The method is able to detect and quantify all five isotopes, with uncertainties and biases usually in the 10-40% range, depending upon the isotopic mixtures and the activity ratios between each of the isotopes.

  4. Intercomparison of Global Precipitation Products: The Third Precipitation Intercomparison Project (PIP-3)

    NASA Technical Reports Server (NTRS)

    Adler, Robert F.; Kidd, Christopher; Petty, Grant; Morrissey, Mark; Goodman, H. Michael; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A set of global, monthly rainfall products has been intercompared to understand the quality and utility of the estimates. The products include 25 observational (satellite-based), four model and two climatological products. The results of the intercomparison indicate a very large range (factor of two or three) of values when all products are considered. The range of values is reduced considerably when the set of observational products is limited to those considered quasi-standard. The model products do significantly poorer in the tropics, but are competitive with satellite-based fields in mid-latitudes over land. Over ocean, products are compared to frequency of precipitation from ship observations. The evaluation of the observational products point to merged data products (including rain gauge information) as providing the overall best results.

  5. The Program for climate Model diagnosis and Intercomparison: 20-th anniversary Symposium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potter, Gerald L; Bader, David C; Riches, Michael

    Twenty years ago, W. Lawrence (Larry) Gates approached the U.S. Department of Energy (DOE) Office of Energy Research (now the Office of Science) with a plan to coordinate the comparison and documentation of climate model differences. This effort would help improve our understanding of climate change through a systematic approach to model intercomparison. Early attempts at comparing results showed a surprisingly large range in control climate from such parameters as cloud cover, precipitation, and even atmospheric temperature. The DOE agreed to fund the effort at the Lawrence Livermore National Laboratory (LLNL), in part because of the existing computing environment andmore » because of a preexisting atmospheric science group that contained a wide variety of expertise. The project was named the Program for Climate Model Diagnosis and Intercomparison (PCMDI), and it has changed the international landscape of climate modeling over the past 20 years. In spring 2009 the DOE hosted a 1-day symposium to celebrate the twentieth anniversary of PCMDI and to honor its founder, Larry Gates. Through their personal experiences, the morning presenters painted an image of climate science in the 1970s and 1980s, that generated early support from the international community for model intercomparison, thereby bringing PCMDI into existence. Four talks covered Gates's early contributions to climate research at the University of California, Los Angeles (UCLA), the RAND Corporation, and Oregon State University through the founding of PCMDI to coordinate the Atmospheric Model Intercomparison Project (AMIP). The speakers were, in order of presentation, Warren Washington [National Center for Atmospheric Research (NCAR)], Kelly Redmond (Western Regional Climate Center), George Boer (Canadian Centre for Climate Modelling and Analysis), and Lennart Bengtsson [University of Reading, former director of the European Centre for Medium-Range Weather Forecasts (ECMWF)]. The afternoon session emphasized the scientific ideas that are the basis of PCMDI's success, summarizing their evolution and impact. Four speakers followed the various PCMDI-supported climate model intercomparison projects, beginning with early work on cloud representations in models, presented by Robert D. Cess (Distinguished Professor Emeritus, Stony Brook University), and then the latest Cloud Feedback Model Intercomparison Projects (CFMIPs) led by Sandrine Bony (Laboratoire de M'©t'©orologie Dynamique). Benjamin Santer (LLNL) presented a review of the climate change detection and attribution (D & A) work pioneered at PCMDI, and Gerald A. Meehl (NCAR) ended the day with a look toward the future of climate change research.« less

  6. Performance testing of radiobioassay laboratories: In vivo measurements, Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLellan, J.A.; Traub, R.J.; Olsen, P.C.

    1990-04-01

    A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection inmore » the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.« less

  7. A Bootstrap Algorithm for Mixture Models and Interval Data in Inter-Comparisons

    DTIC Science & Technology

    2001-07-01

    parametric bootstrap. The present algorithm will be applied to a thermometric inter-comparison, where data cannot be assumed to be normally distributed. 2 Data...experimental methods, used in each laboratory) often imply that the statistical assumptions are not satisfied, as for example in several thermometric ...triangular). Indeed, in thermometric experiments these three probabilistic models can represent several common stochastic variabilities for

  8. Intercomparison of TCCON and MUSICA Water Vapour Products

    NASA Astrophysics Data System (ADS)

    Weaver, D.; Strong, K.; Deutscher, N. M.; Schneider, M.; Blumenstock, T.; Robinson, J.; Notholt, J.; Sherlock, V.; Griffith, D. W. T.; Barthlott, S.; García, O. E.; Smale, D.; Palm, M.; Jones, N. B.; Hase, F.; Kivi, R.; Ramos, Y. G.; Yoshimura, K.; Sepúlveda, E.; Gómez-Peláez, Á. J.; Gisi, M.; Kohlhepp, R.; Warneke, T.; Dohe, S.; Wiegele, A.; Christner, E.; Lejeune, B.; Demoulin, P.

    2014-12-01

    We present an intercomparison between the water vapour products from the Total Carbon Column Observing Network (TCCON) and the MUlti-platform remote Sensing of Isotopologues for investigating the Cycle of Atmospheric water (MUSICA), two datasets from ground-based Fourier Transform InfraRed (FTIR) spectrometers with good global representation. Where possible, comparisons to radiosondes are also included. The near-infrared TCCON measurements are optimized to provide precise monitoring of greenhouse gases for carbon cycle studies; however, TCCON's retrievals also produce water vapour products. The mid-infrared MUSICA products result from retrievals optimized to give precise and accurate information about H2O, HDO, and δD. The MUSICA water vapour products have been validated by extensive intercomparisons with H2O and δD in-situ measurements made from ground, radiosonde, and aircraft (Schneider et al. 2012, 2014), as well as by intercomparisons with satellite-based H2O and δD remote sensing measurements (Wiegele et al., 2014). This dataset provides a valuable reference point for other measurements of water vapour. This study is motivated by the limited intercomparisons performed for TCCON water vapour products and limited characterisation of their uncertainties. We compare MUSICA and TCCON products to assess the potential for TCCON measurements to contribute to studies of the water cycle, water vapour's role in climate and use as a tracer for atmospheric dynamics, and to evaluate the performance of climate models. The TCCON and MUSICA products result from measurements taken using the same FTIR instruments, enabling a comparison with constant instrumentation. The retrieval techniques differ, however, in their method and a priori information. We assess the impact of these differences and characterize the comparability of the TCCON and MUSICA datasets.

  9. An evaluation of the Wyoming Gauge System for snowfall measurement

    USGS Publications Warehouse

    Yang, Daqing; Kane, Douglas L.; Hinzman, Larry D.; Goodison, Barry E.; Metcalfe, John R.; Louie, Paul Y.T.; Leavesley, George H.; Emerson, Douglas G.; Hanson, Clayton L.

    2000-01-01

    The Wyoming snow fence (shield) has been widely used with precipitation gauges for snowfall measurement at more than 25 locations in Alaska since the late 1970s. This gauge's measurements have been taken as the reference for correcting wind‐induced gauge undercatch of snowfall in Alaska. Recently, this fence (shield) was tested in the World Meteorological Organization Solid Precipitation Measurement Intercomparison Project at four locations in the United States of America and Canada for six winter seasons. At the Intercomparison sites an octagonal vertical Double Fence with a Russian Tretyakov gauge or a Universal Belfort recording gauge was installed and used as the Intercomparison Reference (DFIR) to provide true snowfall amounts for this Intercomparison experiment. The Intercomparison data collected were compiled at the four sites that represent a variety of climate, terrain, and exposure. On the basis of these data sets the performance of the Wyoming gauge system for snowfall observations was carefully evaluated against the DFIR and snow cover data. The results show that (1) the mean snow catch efficiency of the Wyoming gauge compared with the DFIR is about 80–90%, (2) there exists a close linear relation between the measurements of the two gauge systems and this relation may serve as a transfer function to adjust the Wyoming gauge records to obtain an estimate of the true snowfall amount, (3) catch efficiency of the Wyoming gauge does not change with wind speed and temperature, and (4) Wyoming gauge measurements are generally compatible to the snowpack water equivalent at selected locations in northern Alaska. These results are important to our effort of determining true snowfall amounts in the high latitudes, and they are also useful for regional hydrologic and climatic analyses.

  10. Water vapour intercomparison effort in the frame of HyMeX-SOP1

    NASA Astrophysics Data System (ADS)

    Summa, Donato; Di Girolamo, Paolo; Stelitano, Dario; Cacciani, Marco; Flamant, Cyrille; Chazette, Patrick; Ducrocq, Véronique; Nuret, Mathieu; Fourié, Nadia; Richard, Evelyne

    2014-05-01

    A water vapour intercomparison effort, involving airborne and ground-based water vapour lidar systems and mesoscale models, was carried out in the framework of the international HyMeX (Hydrological cycle in the Mediterranean Experiment) dedicated to the hydrological cycle and related high-impact events. Within HyMeX, a major field campaign was dedicated to heavy precipitation and flash flood events from 5 September to 6 November 2012. The 2 month field campaign took place over the Northwestern Mediterranean Sea and its surrounding coastal regions in France, Italy, and Spain. The main objective of this work is to provide accurate error estimates for the lidar systems i.e. the ground-based Raman lidar BASIL and the CNRS DIAL Leandre 2 on board the ATR42, as well as use BASIL data to validate mesoscale model results from the MESO NH and Arome WMED. The effort will benefit from the few dedicated ATR42 flights in the frame of the EUFAR Project "WaLiTemp". In the present work our attention was focused on two specific case studies: 13 September and 2 October in the altitude region 0.5 - 5.5 km. Comparisons between the ground-based Raman lidar BASIL and the airborne CNRS DIAL indicate a mean relative bias between the two sensors of 6.5%, while comparisons between BASIL and CNRS DIAL vs. the radiosondes indicate a bias of 2.6 and -3.5 %, respectively. The bias of BASIL vs. the ATR insitu sensor indicate a bias of -20.4 %. Specific attention will also be dedicated to the WALI/BASIL intercomparison effort which took place in Candillargues on 30 October 2012. Specific results from this intercomparison effort and from the intercomparison between BASIL and Meso-NH/AROME-WMed will be illustrated and discussed at the Conference.

  11. An international marine-atmospheric {sup 222}Rn measurement intercomparison in Bermuda. Part 2: Results for the participating laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colle, R.; Unterweger, M.P.; Hutchinson, J.M.R.

    1996-01-01

    As part of an international measurement intercomparison of instruments used to measure atmospheric {sup 222}Rn, four participating laboratories made nearly simultaneous measurements of {sup 222}Rn activity concentration in commonly sampled, ambient air over approximately a 2 week period, and three of these four laboratories participated in the measurement comparison of 14 introduced samples with known, but undisclosed (blind) {sup 222}Rn activity concentration. The exercise was conducted in Bermuda in October 1991. The {sup 222}Rn activity concentrations in ambient Bermudian air over the course of the intercomparison ranged from a few hundredths of a Bq {center_dot} m{sup {minus}3} to about 2more » Bq {center_dot} m{sup {minus}3}, while the standardized sample additions covered a range from approximately 2.5 Bq {center_dot} m{sup {minus}3} to 35 Bq {center_dot} m{sup {minus}3}. The overall uncertainty in the latter concentrations was in the general range of 10%, approximating a 3 standard deviation uncertainty interval. The results of the intercomparison indicated that two of the laboratories were within very good agreement with the standard additions, and almost within expected statistical variations. These same two laboratories, however, at lower ambient concentrations, exhibited a systematic difference with an averaged offset of roughly 0.3 Bq {center_dot} m{sup {minus}3}. The third laboratory participating in the measurement of standardized sample additions was systematically low by about 65% to 70%, with respect to the standard addition which was also confirmed in their ambient air concentration measurements. The fourth laboratory, participating in only the ambient measurement part of the intercomparison, was also systematically low by at least 40% with respect to the first two laboratories.« less

  12. 1989 Intercomparison of radon progeny measurement methods and equipment in North America

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scofield, P.; George, A.; Tu, Keng.

    1990-03-01

    At the 1989 {sup 222}Rn progeny intercomparison held at the Environmental Measurements Laboratory (EML), July 10--14, 1989, grab sampling and integrating/continuous {sup 222}Rn progeny methods were evaluated. Sixteen facilities participated in this intercomparison. Twelve facilities used {sup 222}Rn progeny grab sampling methods, and nine facilities used integrating/continuous instruments. Eighty-eight percent of the participants reported grab sample {sup 222}Rn progeny concentrations that were within 20% of the EML reference values. Good agreement between participant and EML grab-sample potential alpha energy concentrations (PAECs) was observed; 92% of the participants had PAECs within 20% of the EML values. For the integrating/continuous PAEC valuesmore » determined with integrating/continuous monitors, 89% of the participants were within 20% of the EML reference values. 9 refs., 3 figs., 4 tabs.« less

  13. PFLOTRAN-RepoTREND Source Term Comparison Summary.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frederick, Jennifer M.

    Code inter-comparison studies are useful exercises to verify and benchmark independently developed software to ensure proper function, especially when the software is used to model high-consequence systems which cannot be physically tested in a fully representative environment. This summary describes the results of the first portion of the code inter-comparison between PFLOTRAN and RepoTREND, which compares the radionuclide source term used in a typical performance assessment.

  14. GLM Proxy Data Generation: Methods for Stroke/Pulse Level Inter-Comparison of Ground-Based Lightning Reference Networks

    NASA Technical Reports Server (NTRS)

    Cummins, Kenneth L.; Carey, Lawrence D.; Schultz, Christopher J.; Bateman, Monte G.; Cecil, Daniel J.; Rudlosky, Scott D.; Petersen, Walter Arthur; Blakeslee, Richard J.; Goodman, Steven J.

    2011-01-01

    In order to produce useful proxy data for the GOES-R Geostationary Lightning Mapper (GLM) in regions not covered by VLF lightning mapping systems, we intend to employ data produced by ground-based (regional or global) VLF/LF lightning detection networks. Before using these data in GLM Risk Reduction tasks, it is necessary to have a quantitative understanding of the performance of these networks, in terms of CG flash/stroke DE, cloud flash/pulse DE, location accuracy, and CLD/CG classification error. This information is being obtained through inter-comparison with LMAs and well-quantified VLF/LF lightning networks. One of our approaches is to compare "bulk" counting statistics on the spatial scale of convective cells, in order to both quantify relative performance and observe variations in cell-based temporal trends provided by each network. In addition, we are using microsecond-level stroke/pulse time correlation to facilitate detailed inter-comparisons at a more-fundamental level. The current development status of our ground-based inter-comparison and evaluation tools will be presented, and performance metrics will be discussed through a comparison of Vaisala s Global Lightning Dataset (GLD360) with the NLDN at locations within and outside the U.S.

  15. GLM Proxy Data Generation: Methods for Stroke/Pulse Level Inter-comparison of Ground-based Lightning Reference Networks

    NASA Astrophysics Data System (ADS)

    Cummins, K. L.; Carey, L. D.; Schultz, C. J.; Bateman, M. G.; Cecil, D. J.; Rudlosky, S. D.; Petersen, W. A.; Blakeslee, R. J.; Goodman, S. J.

    2011-12-01

    In order to produce useful proxy data for the GOES-R Geostationary Lightning Mapper (GLM) in regions not covered by VLF lightning mapping systems, we intend to employ data produced by ground-based (regional or global) VLF/LF lightning detection networks. Before using these data in GLM Risk Reduction tasks, it is necessary to have a quantitative understanding of the performance of these networks, in terms of CG flash/stroke DE, cloud flash/pulse DE, location accuracy, and CLD/CG classification error. This information is being obtained through inter-comparison with LMAs and well-quantified VLF/LF lightning networks. One of our approaches is to compare "bulk" counting statistics on the spatial scale of convective cells, in order to both quantify relative performance and observe variations in cell-based temporal trends provided by each network. In addition, we are using microsecond-level stroke/pulse time correlation to facilitate detailed inter-comparisons at a more-fundamental level. The current development status of our ground-based inter-comparison and evaluation tools will be presented, and performance metrics will be discussed through a comparison of Vaisala's Global Lightning Dataset (GLD360) with the NLDN at locations within and outside the U.S.

  16. Evaluation of Intercomparisons of Four Different Types of Model Simulating TWP-ICE

    NASA Technical Reports Server (NTRS)

    Petch, Jon; Hill, Adrian; Davies, Laura; Fridlind, Ann; Jakob, Christian; Lin, Yanluan; Xie, Shaoecheng; Zhu, Ping

    2013-01-01

    Four model intercomparisons were run and evaluated using the TWP-ICE field campaign, each involving different types of atmospheric model. Here we highlight what can be learnt from having single-column model (SCM), cloud-resolving model (CRM), global atmosphere model (GAM) and limited-area model (LAM) intercomparisons all based around the same field campaign. We also make recommendations for anyone planning further large multi-model intercomparisons to ensure they are of maximum value to the model development community. CRMs tended to match observations better than other model types, although there were exceptions such as outgoing long-wave radiation. All SCMs grew large temperature and moisture biases and performed worse than other model types for many diagnostics. The GAMs produced a delayed and significantly reduced peak in domain-average rain rate when compared to the observations. While it was shown that this was in part due to the analysis used to drive these models, the LAMs were also driven by this analysis and did not have the problem to the same extent. Based on differences between the models with parametrized convection (SCMs and GAMs) and those without (CRMs and LAMs), we speculate that that having explicit convection helps to constrain liquid water whereas the ice contents are controlled more by the representation of the microphysics.

  17. The Southern Ocean in the Coupled Model Intercomparison Project phase 5

    PubMed Central

    Meijers, A. J. S.

    2014-01-01

    The Southern Ocean is an important part of the global climate system, but its complex coupled nature makes both its present state and its response to projected future climate forcing difficult to model. Clear trends in wind, sea-ice extent and ocean properties emerged from multi-model intercomparison in the Coupled Model Intercomparison Project phase 3 (CMIP3). Here, we review recent analyses of the historical and projected wind, sea ice, circulation and bulk properties of the Southern Ocean in the updated Coupled Model Intercomparison Project phase 5 (CMIP5) ensemble. Improvements to the models include higher resolutions, more complex and better-tuned parametrizations of ocean mixing, and improved biogeochemical cycles and atmospheric chemistry. CMIP5 largely reproduces the findings of CMIP3, but with smaller inter-model spreads and biases. By the end of the twenty-first century, mid-latitude wind stresses increase and shift polewards. All water masses warm, and intermediate waters freshen, while bottom waters increase in salinity. Surface mixed layers shallow, warm and freshen, whereas sea ice decreases. The upper overturning circulation intensifies, whereas bottom water formation is reduced. Significant disagreement exists between models for the response of the Antarctic Circumpolar Current strength, for reasons that are as yet unclear. PMID:24891395

  18. 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swaja, R.E.; Greene, R.T.; Sims, C.S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. This study marked the twentieth in a series of annual accident dosimetry intercomparisons conducted at ORNL. Participants from ten organizations attended this intercomparison and measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results of this study indicate that foil activation techniques are the most popular and accurate method of determining accident-level neutron doses at area monitoringmore » stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants in this study used TLD's to determine gamma doses with very good results on the average. Chemical dosemeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. These results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed.« less

  19. Airborne hygrometer calibration inter-comparison against a metrological water vapour standard

    NASA Astrophysics Data System (ADS)

    Smorgon, Denis; Boese, Norbert; Ebert, Volker

    2014-05-01

    Water vapour is the most important atmospheric greenhouse gas, which causes a major feedback to warming and other changes in the climate system. Knowledge of the distribution of water vapour and its climate induced changes is especially important in the upper troposphere and lower stratosphere (UT/LS) where vapour plays a critical role in atmospheric radiative balance, cirrus cloud formation, and photochemistry. But, our understanding of water in the UT/LS is limited by significant uncertainties in current UT/LS water measurements. One of the most comprehensive inter-comparison campaigns for airborne hygrometers, termed AQUAVIT (AV1) [1], took place in 2007 at the AIDA chamber at the Karlsruhe Institute of Technology (KIT) in Germany. AV1 was a well-defined, referred, blind inter-comparison of 22 airborne field instruments from 17 international research groups. One major metrological deficit of AV1, however, was, that no traceable reference instrument participated in the inter-comparison experiments and that the calibration procedures of the participating instruments were not monitored or interrogated. Consequently a follow-up inter-comparison was organized in April 2013, which for the first time also provides a traceable link to the international humidity scale. This AQUAVIT2 (AV2) campaign (details see: http://www.imk-aaf.kit.edu/aquavit/index.php/Main_Page) was again located at KIT/AIDA and organised by an international organizing committee including KIT, PTB, FZJ and others. Generally AV2 is divided in two parallel comparisons: 1) AV2-A uses the AIDA chamber for a simultaneous comparison of all instruments (incl. sampling and in-situ instruments) over a broad range of conditions characteristic for the UT/LS; 2) AV2-B, about which this paper is reporting, is a sequential comparison of selected hygrometers and (when possible) their reference calibration infrastructures by means of a chilled mirror hygrometer traced back to the primary National humidity standard of PTB and a validated, two-pressure generator acting as a highly stable and reproducible source of water vapour. The aim of AV2-B was to perform an absolute, metrological comparison of the field instruments/calibration infrastructures to the metrological humidity scale, and to collect essential information about methods and procedures used by the atmospheric community for instrument calibration and validation, in order to investigate e.g. the necessity and possible comparability advantage by a standardized calibration procedure. The work will give an overview over the concept of the AV2-B inter-comparison, the various general measurement and calibration principles, and discuss the outcome and consequences of the comparison effort. The AQUAVIT effort is linked to the EMRP project METEOMET (ENV07) and partially supported by the EMRP and ENV07. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. [1] H. Saathoff, C. Schiller, V. Ebert, D. W. Fahey, R.-S. Gao, O. Möhler, and the aquavit team, The AQUAVIT formal intercomparison of atmospheric water measurement methods, 5th General Assembly of the European Geosciences Union, 13-18 April 2008, Vienna, Austria Keywords: humidity, water vapour, inter-comparison, airborne instruments.

  20. NDSC Lidar Intercomparisons and Validation: OPAL and MLO3 Campaigns in 1995

    NASA Technical Reports Server (NTRS)

    McDermid, Stuart; McGee, Thomas J.; Stuart, Daan P. J.

    1996-01-01

    The Network for the Detection of Stratospheric Change (NDSC) has developed and adopted a Validation Policy in order to ensure that the results submitted and stored in its archives are of a known, high quality. As a part of this validation policy, blind instrument intercomparisons are considered an essential element in the certification of NDSC instruments and a specific format for these campaigns has been recommended by the NDSC-Steering Committee.

  1. The April 1992 and November 1992 radon intercomparisons at EML

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisenne, I.M.; George, A.C.; Perry, P.M.

    1993-07-01

    The Environmental Measurements Laboratory hosted two intercomparison exercises in Calendar Year 1992. Thirty-two groups, including US federal facilities, US Department of Energy`s Office of Health and Environmental Research contractors, national and state laboratories, and universities and foreign institutions, participated in these exercises. The majority of the participants` results were within {plus_minus}10% of the EML value at radon concentrations of 2075 and 1650 Bq m{sup {minus}3}.

  2. International round-robin inter-comparison of dye-sensitized and crystalline silicon solar cells

    NASA Astrophysics Data System (ADS)

    Chen, Chia-Yuan; Ahn, Seung Kyu; Aoki, Dasiuke; Kokubo, Junichi; Yoon, Kyung Hoon; Saito, Hidenori; Lee, Kyung Sik; Magaino, Shinichi; Takagi, Katsuhiko; Lin, Ling-Chuan; Lee, Kun-Mu; Wu, Chun-Guey; Zhou, Hong; Igari, Sanekazu

    2017-02-01

    An international round-robin inter-comparison of the spectral responsivity (SR) and current-voltage (I-V) characteristics for dye-sensitized solar cells (DSCs) and crystalline silicon solar cells is reported for the first time. The crystalline silicon cells with various spectral responsivities were also calibrated by AIST to validate this round-robin activity. On the basis of the remarkable consistency in Pmax (within ±1.4% among participants) and Isc (within ±1.2% compared to the primary calibration of AIST) of the silicon specimens, the discrepancy in the SR and photovoltaic parameters of five DSCs among three national laboratories can be verified and diagnosed. Recommendations about sample packages, SR and I-V measurement methods as well as the inter-comparison protocol for improving the performance characterization of the mesoscopic DSCs are presented according to the consolidated data and the experience of the participants.

  3. The April 1994 and October 1994 radon intercomparisons at EML

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisenne, I.M.; George, A.C.; Perry, P.M.

    1995-10-01

    Quality assurance/quality control (QA/QC) are the backbone of many commercial and research processes and programs. QA/QC research tests the state of a functioning system, be it the production of manufactured goods or the ability to make accurate and precise measurements. The quality of the radon measurements in the US have been tested under controlled conditions in semi-annual radon gas intercomparison exercises sponsored by the Environmental Measurements Laboratory (EML) since 1981. The two Calendar Year 1994 radon gas intercomparison exercises were conducted in the EML exposure chamber. Thirty-two groups including US Federal facilities, USDOE contractors, national and state laboratories, universities andmore » foreign institutions participated in these exercises. The majority of the participant`s results were within {+-}10% of the EML value at radon concentrations of 570 and 945 Bq m{sup {minus}3}.« less

  4. The global gridded crop model intercomparison: Data and modeling protocols for Phase 1 (v1.0)

    DOE PAGES

    Elliott, J.; Müller, C.; Deryng, D.; ...

    2015-02-11

    We present protocols and input data for Phase 1 of the Global Gridded Crop Model Intercomparison, a project of the Agricultural Model Intercomparison and Improvement Project (AgMIP). The project consist of global simulations of yields, phenologies, and many land-surface fluxes using 12–15 modeling groups for many crops, climate forcing data sets, and scenarios over the historical period from 1948 to 2012. The primary outcomes of the project include (1) a detailed comparison of the major differences and similarities among global models commonly used for large-scale climate impact assessment, (2) an evaluation of model and ensemble hindcasting skill, (3) quantification ofmore » key uncertainties from climate input data, model choice, and other sources, and (4) a multi-model analysis of the agricultural impacts of large-scale climate extremes from the historical record.« less

  5. Intercomparison and interpretation of climate feedback processes in 19 atmospheric general circulation models

    NASA Technical Reports Server (NTRS)

    Cess, R. D.; Potter, G. L.; Blanchet, J. P.; Boer, G. J.; Del Genio, A. D.

    1990-01-01

    The present study provides an intercomparison and interpretation of climate feedback processes in 19 atmospheric general circulation models. This intercomparison uses sea surface temperature change as a surrogate for climate change. The interpretation of cloud-climate interactions is given special attention. A roughly threefold variation in one measure of global climate sensitivity is found among the 19 models. The important conclusion is that most of this variation is attributable to differences in the models' depiction of cloud feedback, a result that emphasizes the need for improvements in the treatment of clouds in these models if they are ultimately to be used as reliable climate predictors. It is further emphazied that cloud feedback is the consequence of all interacting physical and dynamical processes in a general circulation model. The result of these processes is to produce changes in temperature, moisture distribution, and clouds which are integrated into the radiative response termed cloud feedback.

  6. Inter-comparison between AIRS and IASI through Retrieved Parameters

    NASA Technical Reports Server (NTRS)

    Zhou, Daniel K.; Larar, Allen M.; Smith, William L.; Taylor, Jonathan P.; Schluessel, Peter; Strow, L. Larrabee; Mango, Steve

    2008-01-01

    A State-of-the-art retrieval algorithm dealing with all-weather conditions has been applied to satellite/aircraft instruments retrieving cloud/surface and atmospheric conditions. High quality retrievals have been achieved from IASI data. Surface, cloud, and atmospheric structure and variation are well captured by IASI measurements and/or retrievals. The same retrieval algorithm is also applied to AIRS for retrieval inter-comparison. Both AIRS and IASI have a similar FOV size but AIRS has a higher horizontal resolution. AIRS data can be interpolated to IASI horizontal resolution for inter-comparison at the same geophysical locations, however a temporal variation between AIRS and IASI observations need to be considered. JAIVEx has employed aircraft to obtain the atmospheric variation filling the temporal gap between two satellites. First results show that both AIRS and IASI have a very similar vertical resolving power, atmospheric conditions are well captured by both instruments, and radiances are well calibrated. AIRS data shown in retrievals (e.g., surface emissivity and moisture) have a relatively higher noise level. Since the this type of retrieval is very sensitive to its radiance quality, retrieval products inter-comparison is an effective way to identify/compare their radiance quality, in terms of a combination of spectral resolution and noise level, and to assess instrument performance. Additional validation analyses are needed to provide more-definitive conclusions.

  7. ACIX: Atmospheric Correction Inter-comparison Exercise

    NASA Astrophysics Data System (ADS)

    Doxani, Georgia; Gascon, Ferran; Vermote, Éric; Roger, Jean-Claude

    2017-04-01

    The free and open data access policy to Sentinel-2 (S-2) and Landsat-8 (L-8) satellite imagery has stimulated the development of atmospheric correction (AC) processors for generating Bottom-of-Atmosphere (BOA) products. Several entities have started to generate (or plan to generate in the short term) BOA reflectance products at global scale for S-2 and L-8 missions. To this end, the European Space Agency (ESA) and NASA are organizing an exercise on AC processors inter-comparison. The results of the exercise are expected to point out the strengths and weaknesses, as well as communalities and discrepancies of various AC processors, in order to suggest and define ways for their further improvement. In particular, 13 atmospheric processors from five different countries participate in ACIX with the aim to inter-compare their performance when applied to L-8 and S-2 data. A protocol describing the inter-comparison process and the test dataset, which is based on the AERONET sites, will be presented. The protocol has been defined according to what was agreed among the participants during the 1st ACIX workshop held in June 2016. It includes the comparison of aerosol optical thickness and water vapour products of the processors with the AERONET measurements. Moreover, concerning the surface reflectances, the protocol describes the inter-comparison among the processors, as well as the comparison with the MODIS surface reflectance and with a reference surface reflectance product. Such a reference product will be obtained using the AERONET characterization of the aerosol (size distribution and refractive indices) and an accurate radiative transfer code. The inter-comparison outcomes will be presented and discussed among the participants in the 2nd ACIX workshop, which will be held on 11-12 April 2017 (ESRIN/ESA). The proposed presentation is an opportunity for the user community to be informed for the first time about the ACIX results and conclusions.

  8. ATHLI16: the ATHens Lidar Intercomparison campaign

    NASA Astrophysics Data System (ADS)

    Amodeo, Aldo; D'Amico, Giuseppe; Giunta, Aldo; Papagiannopoulos, Nikolaos; Papayannis, Alex; Argyrouli, Athina; Mylonaki, Maria; Tsaknakis, Georgios; Kokkalis, Panos; Soupiona, Ourania; Tzanis, Chris

    2018-04-01

    The results of the ATHLI16 (ATHens Lidar Intercomparison) campaign, held in Athens from 26/09 to 07/10 2016 are presented. The campaign was performed within the Lidar Calibration Centre activities (EU H2020 ACTRIS-2 project) to assess the performance of the EOLE lidar system (NTUA, Athens, Greece), operating within EARLINET, by comparing against the EARLINET reference lidar system MUSA (CNR-IMAA, Potenza, Italy). For both lidars only products retrieved by the EARLINET Single Calculus Chain have been compared.

  9. Intercomparison of methods for coincidence summing corrections in gamma-ray spectrometry--part II (volume sources).

    PubMed

    Lépy, M-C; Altzitzoglou, T; Anagnostakis, M J; Capogni, M; Ceccatelli, A; De Felice, P; Djurasevic, M; Dryak, P; Fazio, A; Ferreux, L; Giampaoli, A; Han, J B; Hurtado, S; Kandic, A; Kanisch, G; Karfopoulos, K L; Klemola, S; Kovar, P; Laubenstein, M; Lee, J H; Lee, J M; Lee, K B; Pierre, S; Carvalhal, G; Sima, O; Tao, Chau Van; Thanh, Tran Thien; Vidmar, T; Vukanac, I; Yang, M J

    2012-09-01

    The second part of an intercomparison of the coincidence summing correction methods is presented. This exercise concerned three volume sources, filled with liquid radioactive solution. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing corrective factors for several energies of (152)Eu and (134)Cs, and different source-to-detector distances. They are presented and discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. VLBI Digital-Backend Intercomparison Test Report

    NASA Technical Reports Server (NTRS)

    Whitney, Alan; Beaudoin, Christopher; Cappallo, Roger; Niell, Arthur; Petrachenko, Bill; Ruszczyk, Chester A.; Titus, Mike

    2013-01-01

    Issues related to digital-backend (DBE) systems can be difficult to evaluate in either local tests or actual VLBI experiments. The 2nd DBE intercomparison workshop at Haystack Observatory on 25-26 October 2012 provided a forum to explicitly address validation and interoperability issues among independent global developers of DBE equipment. This special report discusses the workshop. It identifies DBE systems that were tested at the workshop, describes the test objectives and procedures, and reports and discusses the results of the testing.

  11. The August 1988 and June 1989 radon intercomparisons at EML (Environmental Measurements Laboratory)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisenne, I.M.; George, A.C.; Keller, H.W.

    1990-06-01

    The Environmental Measurements Laboratory hosted the fifteenth and sixteenth radon intercomparison exercises in August 1988 and June 1989. Forty-five groups including US Federal facilities, USDOE Office of Health and Environmental Research contractors, national and state laboratories and foreign institutions participated in these exercises. The results show that the majority of the participants' results were within {plus minus} of the EML value at radon concentrations of 220 and 890 Bq m{sup {minus}3}. 10 refs., 4 figs., 9 tabs.

  12. Preliminary results of an intercomparison of total ozone spectrophotometers

    NASA Technical Reports Server (NTRS)

    Parsons, C. L.; Gerlach, J. C.; Williams, M. E.; Kerr, J. B.

    1981-01-01

    Preliminary results from an intercomparison of five total ozone spectrophotometers are presented. These are the Dobson spectrophotometer, the USSR M-83 ozonometer, the Canterbury filter photometer, the SenTran Company filter photometer, and the Brewer grating spectrophotometer. The pertinent characteristics of each are described, and conclusions are drawn about the agreement of each instrument's measurements with the Dobson's values over a time period of nearly one year. A discussion of the importance of calibration and long-term stability and reliability is included.

  13. Maintaining High Quality Data and Consistency Across a Diverse Flux Network: The Ameriflux QA/QC Technical Team

    NASA Astrophysics Data System (ADS)

    Chan, S.; Billesbach, D. P.; Hanson, C. V.; Biraud, S.

    2014-12-01

    The AmeriFlux quality assurance and quality control (QA/QC) technical team conducts short term (<2 weeks) intercomparisons using a portable eddy covariance system (PECS) to maintain high quality data observations and data consistency across the AmeriFlux network (http://ameriflux.lbl.gov/). Site intercomparisons identify discrepancies between the in situ and portable measurements and calculated fluxes. Findings are jointly discussed by the site staff and the QA/QC team to improve in the situ observations. Despite the relatively short duration of an individual site intercomparison, the accumulated record of all site visits (numbering over 100 since 2002) is a unique dataset. The ability to deploy redundant sensors provides a rare opportunity to identify, quantify, and understand uncertainties in eddy covariance and ancillary measurements. We present a few specific case studies from QA/QC site visits to highlight and share new and relevant findings related to eddy covariance instrumentation and operation.

  14. The ENEA criticality accident dosimetry system: a contribution to the 2002 international intercomparison at the SILENE reactor.

    PubMed

    Gualdrini, G; Bedogni, R; Fantuzzi, E; Mariotti, F

    2004-01-01

    The present paper summarises the activity carried out at the ENEA Radiation Protection Institute for updating the methodologies employed for the evaluation of the neutron and photon dose to the exposed workers in case of a criticality accident, in the framework of the 'International Intercomparison of Criticality Accident Dosimetry Systems' (Silène reactor, IRSN-CEA-Valduc June 2002). The evaluation of the neutron spectra and the neutron dosimetric quantities relies on activation detectors and on unfolding algorithms. Thermoluminescent detectors are employed for the gamma dose measurement. The work is aimed at accurately characterising the measurement system and, at the same time, testing the algorithms. Useful spectral information were included, based on Monte Carlo simulations, to take into account the potential accident scenarios of practical interest. All along this exercise intercomparison a particular attention was devoted to the 'traceability' of all the experimental and computational parameters and therefore, aimed at an easy treatment by the user.

  15. An overview of sensor calibration inter-comparison and applications

    USGS Publications Warehouse

    Xiong, Xiaoxiong; Cao, Changyong; Chander, Gyanesh

    2010-01-01

    Long-term climate data records (CDR) are often constructed using observations made by multiple Earth observing sensors over a broad range of spectra and a large scale in both time and space. These sensors can be of the same or different types operated on the same or different platforms. They can be developed and built with different technologies and are likely operated over different time spans. It has been known that the uncertainty of climate models and data records depends not only on the calibration quality (accuracy and stability) of individual sensors, but also on their calibration consistency across instruments and platforms. Therefore, sensor calibration inter-comparison and validation have become increasingly demanding and will continue to play an important role for a better understanding of the science product quality. This paper provides an overview of different methodologies, which have been successfully applied for sensor calibration inter-comparison. Specific examples using different sensors, including MODIS, AVHRR, and ETM+, are presented to illustrate the implementation of these methodologies.

  16. BIPM project: Intercomparison of water triple-point cells

    NASA Astrophysics Data System (ADS)

    Chattle, M. V.; Butler, J.

    1994-12-01

    The paper presents the results of an intercomparison between 3 triple point of water cells circulated by the Bureau International des Poids et Measures (BIPM), and a cell which is one of those used as a reference cell at the National Physical Laboratory (NPL). All 4 cells were prepared, stored and measured in the manner normally adopted at NPL. The results of the intercomparison show that over the course of about 6 weeks the temperatures of the 3 circulated cells generally agreed within 0.20 mK, with a maximum difference of 0.27(7) mK. Over the same period, the total variations of temperature measured in the 3 individual cells were 0.04 mK, 0.08 mK and 0.18 mK, respectively; the NPL cell varied by 0.10 mK. Gallium point measurements made over a similar period confirmed that these differences were partly due to small drifts in the thermometer resistance or in the measuring system.

  17. FACE-IT. A Science Gateway for Food Security Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montella, Raffaele; Kelly, David; Xiong, Wei

    Progress in sustainability science is hindered by challenges in creating and managing complex data acquisition, processing, simulation, post-processing, and intercomparison pipelines. To address these challenges, we developed the Framework to Advance Climate, Economic, and Impact Investigations with Information Technology (FACE-IT) for crop and climate impact assessments. This integrated data processing and simulation framework enables data ingest from geospatial archives; data regridding, aggregation, and other processing prior to simulation; large-scale climate impact simulations with agricultural and other models, leveraging high-performance and cloud computing; and post-processing to produce aggregated yields and ensemble variables needed for statistics, for model intercomparison, and to connectmore » biophysical models to global and regional economic models. FACE-IT leverages the capabilities of the Globus Galaxies platform to enable the capture of workflows and outputs in well-defined, reusable, and comparable forms. We describe FACE-IT and applications within the Agricultural Model Intercomparison and Improvement Project and the Center for Robust Decision-making on Climate and Energy Policy.« less

  18. Urine chemistry

    MedlinePlus

    ... rate 24-hour urine protein Acid loading test (pH) Adrenalin - urine test Amylase - urine Bilirubin - urine Calcium - urine Citric acid ... Urine dermatan sulfate Urine - hemoglobin Urine metanephrine Urine pH Urine specific gravity Vanillylmandelic acid (VMA)

  19. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vives i Batlle, J.; Beresford, N. A.; Beaugelin-Seiller, K.

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of 90Sr, 131I and 137Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and whichmore » uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters.« less

  20. The Second Cabauw Intercomparison of Nitrogen Dioxide Measuring Instruments (CINDI-2)

    NASA Astrophysics Data System (ADS)

    Van Roozendael, M.; Hendrick, F.; Apituley, A.; Kreher, K.; Friess, U.; Richter, A.; Wagner, T.; Fehr, T.

    2017-12-01

    For the validation of space borne UV-Vis observations of air quality gases, ground based remote-sensing instruments using the MAXDOAS technique are an excellent choice, since they rely on similar retrieval techniques as the observations from orbit. Over the last decade, MAXDOAS instruments of various designs (including PANDORA systems) have been deployed worldwide forming the basis for a global ground based reference network suitable for the validation of future satellite sensors, such as TROPOMI/Sentinel-5 precursor, GEMS, TEMPO, and Sentinel 4 and 5. To ensure proper traceability of these observations, assess their accuracy and progress towards harmonized data acquisition and delivery, a thorough intercomparison campaign known as the Second Cabauw Intercomparison of Nitrogen Dioxide Measuring Instruments (CINDI-2) was held in Cabauw, The Netherlands during the month of September 2016. About 35 MAXDOAS instruments operated by 25 different groups were deployed, together with systems providing key ancillary in-situ measurements of NO2 and aerosol optical properties, as well as vertical profiles of NO2 by lidar and sonde and vertical profiles of aerosol optical properties by Raman lidar. We provide an overview of the main outcome of the campaign, which included a formal semi-blind slant column intercomparison and a number of additional exercises aiming at assessing the potential of the MAXDOAS technique for retrieving vertically-resolved information on NO2, aerosol, HCHO, O3 and a few other more challenging species such as HONO and glyoxal.

  1. The 1996 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers

    PubMed Central

    Early, Edward; Thompson, Ambler; Johnson, Carol; DeLuisi, John; Disterhoft, Patrick; Wardle, David; Wu, Edmund; Mou, Wanfeng; Ehramjian, James; Tusson, John; Mestechkina, Tanya; Beaubian, Mark; Gibson, James; Hayes, Douglass

    1998-01-01

    Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, the third North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers was held June 17–25, 1996 at Table Mountain outside Boulder, Colorado, USA. This Intercomparison was coordinated by the National Institute of Standards and Technology (NIST) and the National Oceanic and Atmospheric Administration (NOAA). Participating agencies were the Environmental Protection Agency; the National Science Foundation; the Smithsonian Environmental Research Center; the Department of Agriculture; and the Atmospheric Environment Service, Canada. The spectral irradiances of participants’ calibrated standard lamps were measured at NIST prior to the Intercomparison. The spectral irradiance scales used by the participants agreed with the NIST scale within the combined uncertainties, and for all lamps the spectral irradiance in the horizontal position was lower than that in the vertical position. Instruments were characterized for wavelength uncertainty, bandwidth, stray-light rejection, and spectral irradiance responsivity, the latter with NIST standard lamps operating in specially designed field calibration units. The spectral irradiance responsivity demonstrated instabilities for some instruments. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST standard lamps, the measured solar irradiances had some unexplained systematic differences between instruments. PMID:28009358

  2. An intercomparison of aircraft instrumentation for tropospheric measurements of sulfur dioxide

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Davis, Douglas D.; Beltz, Nobert; Bandy, Alan R.; Ferek, Ronald J.; Thornton, Donald C.

    1993-01-01

    As part of the NASA Tropospheric Chemistry Program, a series of field intercomparisons have been conducted to evaluate the state-of-the art for measuring key tropospheric species. One of the objectives of the third intercomparison campaign in this series, Chemical Instrumentation Test and Evaluation 3 (CITE 3), was to evaluate instrumentation for making reliable tropospheric aircraft measurements of sulfur dioxide, dimethyl sulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide. This paper reports the results of the intercomparisons of five sulfur dioxide measurement methods ranging from filter techniques, in which samples collected in flight are returned to the laboratory for analyses (chemiluminescent or ion chromatographic), to near real-time, in-flight measurements via gas chromatographic, mass spectrometric, and chemiluminescent techniques. All techniques showed some tendency to track sizeable changes in ambient SO2 such as those associated with altitude changes. For SO2 mixing ratios in the range of 200 pptv to a few ppbv, agreement among the techniques varies from about 30% to several orders of magnitude, depending upon the pair of measurements intercompared. For SO2 mixing ratios less than 200 pptv, measurements from the techniques are uncorrelated. In general, observed differences in the measurement of standards do not account for the flight results. The CITE 3 results do not unambiguously identify one or more of the measurement techniques as providing valid or invalid SO2 measurements, but identify the range of 'potential' uncertainty in SO2 measurements reported by currently available instrumentation and as measured under realistic aircraft environments.

  3. Design of the MISMIP+, ISOMIP+, and MISOMIP ice-sheet, ocean, and coupled ice sheet-ocean intercomparison projects

    NASA Astrophysics Data System (ADS)

    Asay-Davis, Xylar; Cornford, Stephen; Martin, Daniel; Gudmundsson, Hilmar; Holland, David; Holland, Denise

    2015-04-01

    The MISMIP and MISMIP3D marine ice sheet model intercomparison exercises have become popular benchmarks, and several modeling groups have used them to show how their models compare to both analytical results and other models. Similarly, the ISOMIP (Ice Shelf-Ocean Model Intercomparison Project) experiments have acted as a proving ground for ocean models with sub-ice-shelf cavities.As coupled ice sheet-ocean models become available, an updated set of benchmark experiments is needed. To this end, we propose sequel experiments, MISMIP+ and ISOMIP+, with an end goal of coupling the two in a third intercomparison exercise, MISOMIP (the Marine Ice Sheet-Ocean Model Intercomparison Project). Like MISMIP3D, the MISMIP+ experiments take place in an idealized, three-dimensional setting and compare full 3D (Stokes) and reduced, hydrostatic models. Unlike the earlier exercises, the primary focus will be the response of models to sub-shelf melting. The chosen configuration features an ice shelf that experiences substantial lateral shear and buttresses the upstream ice, and so is well suited to melting experiments. Differences between the steady states of each model are minor compared to the response to melt-rate perturbations, reflecting typical real-world applications where parameters are chosen so that the initial states of all models tend to match observations. The three ISOMIP+ experiments have been designed to to make use of the same bedrock topography as MISMIP+ and using ice-shelf geometries from MISMIP+ results produced by the BISICLES ice-sheet model. The first two experiments use static ice-shelf geometries to simulate the evolution of ocean dynamics and resulting melt rates to a quasi-steady state when far-field forcing changes in either from cold to warm or from warm to cold states. The third experiment prescribes 200 years of dynamic ice-shelf geometry (with both retreating and advancing ice) based on a BISICLES simulation along with similar flips between warm and cold states in the far-field ocean forcing. The MISOMIP experiment combines the MISMIP+ experiments with the third ISOMIP+ experiment. Changes in far-field ocean forcing lead to a rapid (over ~1-2 years) increase in sub-ice-shelf melting, which is allowed to drive ice-shelf retreat for ~100 years. Then, the far-field forcing is switched to a cold state, leading to a rapid decrease in melting and a subsequent advance over ~100 years. To illustrate, we present results from BISICLES and POP2x experiments for each of the three intercomparison exercises.

  4. Intercomparison of Operational Ocean Forecasting Systems in the framework of GODAE

    NASA Astrophysics Data System (ADS)

    Hernandez, F.

    2009-04-01

    One of the main benefits of the GODAE 10-year activity is the implementation of ocean forecasting systems in several countries. In 2008, several systems are operated routinely, at global or basin scale. Among them, the BLUElink (Australia), HYCOM (USA), MOVE/MRI.COM (Japan), Mercator (France), FOAM (United Kingdom), TOPAZ (Norway) and C-NOOFS (Canada) systems offered to demonstrate their operational feasibility by performing an intercomparison exercise during a three months period (February to April 2008). The objectives were: a) to show that operational ocean forecasting systems are operated routinely in different countries, and that they can interact; b) to perform in a similar way a scientific validation aimed to assess the quality of the ocean estimates, the performance, and forecasting capabilities of each system; and c) to learn from this intercomparison exercise to increase inter-operability and collaboration in real time. The intercomparison relies on the assessment strategy developed for the EU MERSEA project, where diagnostics over the global ocean have been revisited by the GODAE contributors. This approach, based on metrics, allow for each system: a) to verify if ocean estimates are consistent with the current general knowledge of the dynamics; and b) to evaluate the accuracy of delivered products, compared to space and in-situ observations. Using the same diagnostics also allows one to intercompare the results from each system consistently. Water masses and general circulation description by the different systems are consistent with WOA05 Levitus climatology. The large scale dynamics (tropical, subtropical and subpolar gyres ) are also correctly reproduced. At short scales, benefit of high resolution systems can be evidenced on the turbulent eddy field, in particular when compared to eddy kinetic energy deduced from satellite altimetry of drifter observations. Comparisons to high resolution SST products show some discrepancies on ocean surface representation, either due to model and forcing fields errors, or assimilation scheme efficiency. Comparisons to sea-ice satellite products also evidence discrepancies linked to model, forcing and assimilation strategies of each forecasting system. Key words: Intercomparison, ocean analysis, operational oceanography, system assessment, metrics, validation GODAE Intercomparison Team: L. Bertino (NERSC/Norway), G. Brassington (BMRC/Australia), E. Chassignet (FSU/USA), J. Cummings (NRL/USA), F. Davidson (DFO/Canda), M. Drévillon (CERFACS/France), P. Hacker (IPRC/USA), M. Kamachi (MRI/Japan), J.-M. Lellouche (CERFACS/France), K. A. Lisæter (NERSC/Norway), R. Mahdon (UKMO/UK), M. Martin (UKMO/UK), A. Ratsimandresy (DFO/Canada), and C. Regnier (Mercator Ocean/France)

  5. GEOS observation systems intercomparison investigation results

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1974-01-01

    The results of an investigation designed to determine the relative accuracy and precision of the different types of geodetic observation systems used by NASA is presented. A collocation technique was used to minimize the effects of uncertainties in the relative station locations and in the earth's gravity field model by installing accurate reference tracking systems close to the systems to be compared, and by precisely determining their relative survey. The Goddard laser and camera systems were shipped to selected sites, where they tracked the GEOS satellite simultaneously with other systems for an intercomparison observation.

  6. Intercomparison of techniques for the non-invasive measurement of bone mass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohn, S.H.

    1981-01-01

    A variety of methods are presently available for the non-invasive measurement of bone mass of both normal individuals and patients with metabolic disorders. Chief among these methods are radiographic techniques such as radiogrammetry, photon absorptiometry, computer tomography, Compton scattering and neutron activation analysis. In this review, the salient features of the bone measurement techniques are discussed along with their accuracy and precision. The advantages and disadvantages of the various techniques for measuring bone mass are summarized. Where possible, intercomparisons are made of the various techniques.

  7. Intercomparison of photon dose measurements at the 8 MeV electron accelerator

    NASA Astrophysics Data System (ADS)

    Angelescu, T.; Ghiordănescu, N.; Băl ţă ţeanu, N.; Labău, V.; Vasilescu, A.

    1997-02-01

    Measurements of dose with thermoluminescent detectors (TLD) and an ionisation chamber were performed in the range of 5-70 Gy in the electron bremsstrahlung field with a maximum energy of 8 MeV of the Bucharest linear accelerator. Previous calibration was done with a 60Co source. The results of the intercomparison were used in dosimetry of the n - γ field of the ΣΣ irradiation facility, with a photon spectrum similar to the 8 MeV bremsstrahlung field [T. Angelescu et al., Nucl. Instr. and Meth. A 378 (1996) 594].

  8. Visible light nitrogen dioxide spectrophotometer intercomparison: Mount Kobau, British Columbia, July 28 to August 10, 1991

    NASA Technical Reports Server (NTRS)

    Mcelroy, C. T.; Elokhov, A. S.; Elansky, N.; Frank, H.; Johnston, P.; Kerr, J. B.

    1994-01-01

    Under the auspices of the World Meteorological Organization, Environment Canada hosted an international comparison of visible light spectrophotometers at Mt. Kobau, British Columbia in August of 1991. Instruments from four countries were involved. The intercomparison results have indicated that some significant differences exist in the responses of the various instruments, and have provided a basis for the comparison of the historical data sets which currently exist as a result of the independent researches carried out in the past in the former Soviet Union, New Zealand, and Canada.

  9. Catecholamines - urine

    MedlinePlus

    Dopamine - urine test; Epinephrine - urine test; Adrenalin - urine test; Urine metanephrine; Normetanephrine; Norepinephrine - urine test; Urine catecholamines; VMA; HVA; Metanephrine; Homovanillic ...

  10. First results of the CINDI-2 semi-blind MAX-DOAS intercomparison

    NASA Astrophysics Data System (ADS)

    Kreher, Karin; van Roozendael, Michel; Hendrick, Francois; Apituley, Arnoud; Friess, Udo; Lampel, Johannes; Piters, Ankie; Richter, Andreas; Wagner, Thomas; Cindi-2 Participants, All

    2017-04-01

    The second Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI-2) took place at the Cabauw Experimental Site for Atmospheric Research (CESAR; Utrecht area, The Netherlands) from 25 August until 7 October 2016. The goals of this inter-comparison campaign are to support the creation of high-quality ground-based data sets (e.g. to provide reliable long-term time series for trend analysis and satellite data validation), to characterise and better understand the differences between a large number of MAX-DOAS and DOAS instruments and analysis methods, and to contribute to a harmonisation of the measurement settings and retrieval methods. During a time period of 17 days, from 12 to 28 September 2016, a formal semi-blind intercomparison was held following a detailed measurement protocol. The development of this protocol was based on the experience gained during the first CINDI campaign held in 2009 as well as more recent projects and campaigns such as the MADCAT campaign in Mainz, Germany, in 2013. Strong emphasis was put on the careful synchronisation of the measurement sequence and on exact alignment of the elevation angles using horizon scans and lamp measurements. In this presentation, we provide an overview and some highlights of the MAX-DOAS semi-blind intercomparison campaign. We will introduce the participating groups, their instruments and the measurement protocol details, and then summarize the campaign outcomes to date. The CINDI-2 data sets have been investigated using a range of diagnostics including comparisons of daily time series and relative differences between the data sets, regression analysis and correlation plots. The data products so far investigated are NO2 (nitrogen dioxide) in the UV and visible wavelength region, O4 (oxygen dimer) in the same two wavelength intervals, O3 (ozone) in the UV and visible wavelength region, HCHO (formaldehyde) and NO2 in an additional (smaller) wavelength range in the visible. The results based on the regression analysis are presented in summary plots and tables, addressing MAX-DOAS and twilight zenith sky measurements separately. Further information on instrumental details such as the alignment of the viewing direction and elevation and the field of view are also summarized and included in the overall interpretation.

  11. Atmospheric Correction Inter-comparison Exercise (ACIX)

    NASA Astrophysics Data System (ADS)

    Vermote, E.; Doxani, G.; Gascon, F.; Roger, J. C.; Skakun, S.

    2017-12-01

    The free and open data access policy to Landsat-8 (L-8) and Sentinel-2 (S-2) satellite imagery has encouraged the development of atmospheric correction (AC) approaches for generating Bottom-of-Atmosphere (BOA) products. Several entities have started to generate (or plan to generate in the short term) BOA reflectance products at global scale for L-8 and S-2 missions. To this end, the European Space Agency (ESA) and National Aeronautics and Space Administration (NASA) have initiated an exercise on the inter-comparison of the available AC processors. The results of the exercise are expected to point out the strengths and weaknesses, as well as communalities and discrepancies of various AC processors, in order to suggest and define ways for their further improvement. In particular, 11 atmospheric processors from five different countries participate in ACIX with the aim to inter-compare their performance when applied to L-8 and S-2 data. All the processors should be operational without requiring parametrization when applied on different areas. A protocol describing in details the inter-comparison metrics and the test dataset based on the AERONET sites has been agreed unanimously during the 1st ACIX workshop in June 2016. In particular, a basic and an advanced run of each of the processor were requested in the frame of ACIX, with the aim to draw robust and reliable conclusions on the processors' performance. The protocol also describes the comparison metrics of the aerosol optical thickness and water vapour products of the processors with the corresponding AERONET measurements. Moreover, concerning the surface reflectances, the inter-comparison among the processors is defined, as well as the comparison with the MODIS surface reflectance and with a reference surface reflectance product. Such a reference product will be obtained using the AERONET characterization of the aerosol (size distribution and refractive indices) and an accurate radiative transfer code. The inter-comparison outcomes were presented and discussed among the ACIX participants in the 2nd ACIX workshop, which was held on 11-12 April 2017 (ESRIN/ESA) and a detailed report was compiled. The proposed presentation is an opportunity for the user community to be informed about the ACIX results and conclusions.

  12. Stratospheric Ozone Intercomparison Campaign (STOIC) 1989: Overview

    NASA Technical Reports Server (NTRS)

    Margitan, J. J.; Barnes, R. A.; Brothers, G. B.; Butler, J.; Burris, J.; Connor, B. J.; Ferrare, R. A.; Kerr, J. B.; Komhyr, W. D.; McCormick, M. P.; hide

    1995-01-01

    The NASA Upper Atmosphere Research Program organized a Stratospheric Ozone Intercomparison Campaign (STOIC) held in July-August 1989 at the Table Mountain Facility (TMF) of the Jet Propulsion Laboratory (JPL). The primary instruments participating in this campaign were several that had been developed by NASA for the Network for the Detection of Stratospheric Change: the JPL ozone lidar at TMF, the Goddard Space Flight Center trailer-mounted ozone lidar which was moved to TMF for this comparison, and the Millitech/LaRC microwave radiometer. To assess the performance of these new instruments, a validation/intercomparison campaign was undertaken using established techniques: balloon ozonesondes launched by personnel from the Wallops Flight Facility and from NOAA Geophysical Monitoring for Climate Change (GMCC) (now Climate Monitoring and Diagnostics Laboratory), a NOAA GMCC Dobson spectrophotometer, and a Brewer spectrometer from the Atmospheric Environment Service of Canada, both being used for column as well as Umkehr profile retrievals. All of these instruments were located at TMF and measurements were made as close together in time as possible to minimize atmospheric variability as a factor in the comparisons. Daytime rocket measurements of ozone were made by Wallops Flight Facility personnel using ROCOZ-A instruments launched from San Nicholas Island. The entire campaign was conducted as a blind intercomparison, with the investigators not seeing each others data until all data had been submitted to a referee and archived at the end of the 2-week period (July 20 to August 2, 1989). Satellite data were also obtained from the Stratospheric Aerosol and Gas Experiment (SAGE 2) aboard the Earth Radiation Budget Satellite and the Total Ozone Mapping Spectrometer (TOMS) aboard Nimbus 7. An examination of the data has found excellent agreement among the techniques, especially in the 20- to 40-km range. As expected, there was little atmospheric variability during the intercomparison, allowing for detailed statistical comparisons at a high level of precision. This overview paper summarizes the campaign and provides a 'road map' to subsequent papers in this issue by the individual instrument teams which will present more detailed analysis of the data and conclusions.

  13. Radiance and Jacobian Intercomparison of Radiative Transfer Models Applied to HIRS and AMSU Channels

    NASA Technical Reports Server (NTRS)

    Garand, L.; Turner, D. S.; Larocque, M.; Bates, J.; Boukabara, S.; Brunel, P.; Chevallier, F.; Deblonde, G.; Engelen, R.; Hollingshead, M.; hide

    2000-01-01

    The goals of this study are the evaluation of current fast radiative transfer models (RTMs) and line-by-line (LBL) models. The intercomparison focuses on the modeling of 11 representative sounding channels routinely used at numerical weather prediction centers: 7 HIRS (High-resolution Infrared Sounder) and 4 AMSU (Advanced Microwave Sounding Unit) channels. Interest in this topic was evidenced by the participation of 24 scientists from 16 institutions. An ensemble of 42 diverse atmospheres was used and results compiled for 19 infrared models and 10 microwave models, including several LBL RTMs. For the first time, not only radiances, but also Jacobians (of temperature, water vapor and ozone) were compared to various LBL models for many channels. In the infrared, LBL models typically agree to within 0.05-0.15 K (standard deviation) in terms of top-of-the-atmosphere brightness temperature (BT). Individual differences up to 0.5 K still exist, systematic in some channels, and linked to the type of atmosphere in others. The best fast models emulate LBL BTs to within 0.25 K, but no model achieves this desirable level of success for all channels. The ozone modeling is particularly challenging, In the microwave, fast models generally do quite well against the LBL model to which they were tuned. However significant differences were noted among LBL models, Extending the intercomparison to the Jacobians proved very useful in detecting subtle and more obvious modeling errors. In addition, total and single gas optical depths were calculated, which provided additional insight on the nature of differences. Recommendations for future intercomparisons are suggested.

  14. Radiance and Jacobian Intercomparison of Radiative Transfer Models Applied to HIRS and AMSU Channels

    NASA Technical Reports Server (NTRS)

    Garand, L.; Turner, D. S.; Larocque, M.; Bates, J.; Boukabara, S.; Brunel, P.; Chevallier, F.; Deblonde, G.; Engelen, R.; Atlas, Robert (Technical Monitor)

    2000-01-01

    The goals of this study are the evaluation of current fast radiative transfer models (RTMs) and line-by-line (LBL) models. The intercomparison focuses on the modeling of 11 representative sounding channels routinely used at numerical weather prediction centers: seven HIRS (High-resolution Infrared Sounder) and four AMSU (Advanced Microwave Sounding Unit) channels. Interest in this topic was evidenced by the participation of 24 scientists from 16 institutions. An ensemble of 42 diverse atmospheres was used and results compiled for 19 infrared models and 10 microwave models, including several LBL RTMs. For the first time, not only radiances, but also Jacobians (of temperature, water vapor, and ozone) were compared to various LBL models for many channels. In the infrared, LBL models typically agree to within 0.05-0.15 K (standard deviation) in terms of top-of-the-atmosphere brightness temperature (BT). Individual differences up to 0.5 K still exist, systematic in some channels, and linked to the type of atmosphere in others. The best fast models emulate LBL BTs to within 0.25 K, but no model achieves this desirable level of success for all channels. The ozone modeling is particularly challenging. In the microwave, fast models generally do quite well against the LBL model to which they were tuned. However significant differences were noted among LBL models. Extending the intercomparison to the Jacobians proved very useful in detecting subtle and more obvious modeling errors. In addition, total and single gas optical depths were calculated, which provided additional insight on the nature of differences. Recommendations for future intercomparisons are suggested.

  15. The 1997 North American Interagency Intercomparison of Ultraviolet Spectroradiometers Including Narrowband Filter Radiometers

    PubMed Central

    Lantz, Kathleen; Disterhoft, Patrick; Early, Edward; Thompson, Ambler; DeLuisi, John; Berndt, Jerry; Harrison, Lee; Kiedron, Peter; Ehramjian, James; Bernhard, Germar; Cabasug, Lauriana; Robertson, James; Mou, Wanfeng; Taylor, Thomas; Slusser, James; Bigelow, David; Durham, Bill; Janson, George; Hayes, Douglass; Beaubien, Mark; Beaubien, Arthur

    2002-01-01

    The fourth North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held September 15 to 25, 1997 at Table Mountain outside of Boulder, Colorado, USA. Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. The main purpose of the Intercomparison was to assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks. This Intercomparison was coordinated by NIST and NOAA, and included participants from the ASRC, EPA, NIST, NSF, SERC, USDA, and YES. The UV measuring instruments included scanning spectroradiometers, spectrographs, narrow band multi-filter radiometers, and broadband radiometers. Instruments were characterized for wavelength accuracy, bandwidth, stray-light rejection, and spectral irradiance responsivity. The spectral irradiance responsivity was determined two to three times outdoors to assess temporal stability. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST traceable standard lamp, and a simple convolution technique with a Gaussian slit-scattering function to account for the different bandwidths of the instruments, the measured solar irradiance from the spectroradiometers excluding the filter radiometers at 16.5 h UTC had a relative standard deviation of ±4 % for wavelengths greater than 305 nm. The relative standard deviation for the solar irradiance at 16.5 h UTC including the filter radiometer was ±4 % for filter functions above 300 nm. PMID:27446717

  16. GMMIP (v1.0) contribution to CMIP6: Global Monsoons Model Inter-comparison Project

    NASA Astrophysics Data System (ADS)

    Zhou, Tianjun; Turner, Andrew G.; Kinter, James L.; Wang, Bin; Qian, Yun; Chen, Xiaolong; Wu, Bo; Wang, Bin; Liu, Bo; Zou, Liwei; He, Bian

    2016-10-01

    The Global Monsoons Model Inter-comparison Project (GMMIP) has been endorsed by the panel of Coupled Model Inter-comparison Project (CMIP) as one of the participating model inter-comparison projects (MIPs) in the sixth phase of CMIP (CMIP6). The focus of GMMIP is on monsoon climatology, variability, prediction and projection, which is relevant to four of the "Grand Challenges" proposed by the World Climate Research Programme. At present, 21 international modeling groups are committed to joining GMMIP. This overview paper introduces the motivation behind GMMIP and the scientific questions it intends to answer. Three tiers of experiments, of decreasing priority, are designed to examine (a) model skill in simulating the climatology and interannual-to-multidecadal variability of global monsoons forced by the sea surface temperature during historical climate period; (b) the roles of the Interdecadal Pacific Oscillation and Atlantic Multidecadal Oscillation in driving variations of the global and regional monsoons; and (c) the effects of large orographic terrain on the establishment of the monsoons. The outputs of the CMIP6 Diagnostic, Evaluation and Characterization of Klima experiments (DECK), "historical" simulation and endorsed MIPs will also be used in the diagnostic analysis of GMMIP to give a comprehensive understanding of the roles played by different external forcings, potential improvements in the simulation of monsoon rainfall at high resolution and reproducibility at decadal timescales. The implementation of GMMIP will improve our understanding of the fundamental physics of changes in the global and regional monsoons over the past 140 years and ultimately benefit monsoons prediction and projection in the current century.

  17. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario.

    PubMed

    Vives I Batlle, J; Beresford, N A; Beaugelin-Seiller, K; Bezhenar, R; Brown, J; Cheng, J-J; Ćujić, M; Dragović, S; Duffa, C; Fiévet, B; Hosseini, A; Jung, K T; Kamboj, S; Keum, D-K; Kryshev, A; LePoire, D; Maderich, V; Min, B-I; Periáñez, R; Sazykina, T; Suh, K-S; Yu, C; Wang, C; Heling, R

    2016-03-01

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of (90)Sr, (131)I and (137)Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and which uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Urinalysis: MedlinePlus Health Topic

    MedlinePlus

    ... Urine odor (Medical Encyclopedia) Also in Spanish Urine pH test (Medical Encyclopedia) Also in Spanish Urine specific gravity ... Urine - abnormal color Urine - bloody Urine odor Urine pH test Urine specific gravity test Show More Show Less ...

  19. Status report on the Zagreb Radiocarbon Laboratory - AMS and LSC results of VIRI intercomparison samples

    NASA Astrophysics Data System (ADS)

    Sironić, Andreja; Krajcar Bronić, Ines; Horvatinčić, Nada; Barešić, Jadranka; Obelić, Bogomil; Felja, Igor

    2013-01-01

    A new line for preparation of the graphite samples for 14C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. 14C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 ± 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  20. An Overview of Measurement Comparisons from the INTEX-B/MILAGRO Airborne Field Campaign

    NASA Technical Reports Server (NTRS)

    Kleb, Mary M.; Chen, Gao; Crawford, James H.; Flocke, Frank M.; Brown, Clyde C.

    2011-01-01

    As part of the NASA's INTEX-B mission, the NASA DC-8 and NSF C-130 conducted three wing-tip to wing-tip comparison flights. The intercomparison flights sampled a variety of atmospheric conditions (polluted urban, non-polluted, marine boundary layer, clean and polluted free troposphere). These comparisons form a basis to establish data consistency, but also should also be viewed as a continuation of efforts aiming to better understand and reduce measurement differences as identified in earlier field intercomparison exercises. This paper provides a comprehensive overview of 140 intercomparisons of data collected as well as a record of the measurement consistency demonstrated during INTEX-B. It is the primary goal to provide necessary information for the future research to determine if the observations from different INTEX-B platforms/instrument are consistent within the PI reported uncertainties and used in integrated analysis. This paper may also contribute to the formulation strategy for future instrument developments. For interpretation and most effective use of these results, the reader is strongly urged to consult with the instrument principle investigator.

  1. Ice Sheet Model Intercomparison Project (ISMIP6) contribution to CMIP6

    PubMed Central

    Nowicki, Sophie M.J.; Payne, Tony; Larour, Eric; Seroussi, Helene; Goelzer, Heiko; Lipscomb, William; Gregory, Jonathan; Abe-Ouchi, Ayako; Shepherd, Andrew

    2018-01-01

    Reducing the uncertainty in the past, present and future contribution of ice sheets to sea-level change requires a coordinated effort between the climate and glaciology communities. The Ice Sheet Model Intercomparison Project for CMIP6 (ISMIP6) is the primary activity within the Coupled Model Intercomparison Project – phase 6 (CMIP6) focusing on the Greenland and Antarctic Ice Sheets. In this paper, we describe the framework for ISMIP6 and its relationship to other activities within CMIP6. The ISMIP6 experimental design relies on CMIP6 climate models and includes, for the first time within CMIP, coupled ice sheet – climate models as well as standalone ice sheet models. To facilitate analysis of the multi-model ensemble and to generate a set of standard climate inputs for standalone ice sheet models, ISMIP6 defines a protocol for all variables related to ice sheets. ISMIP6 will provide a basis for investigating the feedbacks, impacts, and sea-level changes associated with dynamic ice sheets and for quantifying the uncertainty in ice-sheet-sourced global sea-level change. PMID:29697697

  2. Results of the Greenland ice sheet model initialisation experiments: ISMIP6 - initMIP-Greenland

    NASA Astrophysics Data System (ADS)

    Goelzer, Heiko; Nowicki, Sophie; Edwards, Tamsin; Beckley, Matthew

    2017-04-01

    Ice sheet model initialisation has a large effect on projected future sea-level contributions and gives rise to important uncertainties. The goal of this intercomparison exercise for the continental-scale Greenland ice sheet is therefore to compare, evaluate and improve the initialisation techniques used in the ice sheet modelling community. The initMIP-Greenland project is the first in a series of ice sheet model intercomparison activities within ISMIP6 (Ice Sheet Model Intercomparison Project for CMIP6). The experimental set-up has been designed to allow comparison of the initial present-day state of the Greenland ice sheet between participating models and against observations. Furthermore, the initial states are tested with two schematic forward experiments to evaluate the initialisation in terms of model drift (forward run without any forcing) and response to a large perturbation (prescribed surface mass balance anomaly). We present and discuss results that highlight the wide diversity of data sets, boundary conditions and initialisation techniques used in the community to generate initial states of the Greenland ice sheet.

  3. The Continuous Intercomparison of Radiation Codes (CIRC): Phase I Cases

    NASA Technical Reports Server (NTRS)

    Oreopoulos, Lazaros; Mlawer, Eli; Delamere, Jennifer; Shippert, Timothy; Turner, David D.; Miller, Mark A.; Minnis, Patrick; Clough, Shepard; Barker, Howard; Ellingson, Robert

    2007-01-01

    CIRC aspires to be the successor to ICRCCM (Intercomparison of Radiation Codes in Climate Models). It is envisioned as an evolving and regularly updated reference source for GCM-type radiative transfer (RT) code evaluation with the principle goal to contribute in the improvement of RT parameterizations. CIRC is jointly endorsed by DOE's Atmospheric Radiation Measurement (ARM) program and the GEWEX Radiation Panel (GRP). CIRC's goal is to provide test cases for which GCM RT algorithms should be performing at their best, i.e, well characterized clear-sky and homogeneous, overcast cloudy cases. What distinguishes CIRC from previous intercomparisons is that its pool of cases is based on observed datasets. The bulk of atmospheric and surface input as well as radiative fluxes come from ARM observations as documented in the Broadband Heating Rate Profile (BBHRP) product. BBHRP also provides reference calculations from AER's RRTM RT algorithms that can be used to select the most optimal set of cases and to provide a first-order estimate of our ability to achieve radiative flux closure given the limitations in our knowledge of the atmospheric state.

  4. Ice Sheet Model Intercomparison Project (ISMIP6) Contribution to CMIP6

    NASA Technical Reports Server (NTRS)

    Nowicki, Sophie M. J.; Payne, Tony; Larour, Eric; Seroussi, Helene; Goelzer, Heiko; Lipscomb, William; Gregory, Jonathan; Abe-Ouchi, Ayako; Shepherd, Andrew

    2016-01-01

    Reducing the uncertainty in the past, present, and future contribution of ice sheets to sea-level change requires a coordinated effort between the climate and glaciology communities. The Ice Sheet Model Intercomparison Project for CMIP6 (ISMIP6) is the primary activity within the Coupled Model Intercomparison Project phase 6 (CMIP6) focusing on the Greenland and Antarctic ice sheets. In this paper, we describe the framework for ISMIP6 and its relationship with other activities within CMIP6. The ISMIP6 experimental design relies on CMIP6 climate models and includes, for the first time within CMIP, coupled ice-sheetclimate models as well as standalone ice-sheet models. To facilitate analysis of the multi-model ensemble and to generate a set of standard climate inputs for standalone ice-sheet models, ISMIP6 defines a protocol for all variables related to ice sheets. ISMIP6 will provide a basis for investigating the feedbacks, impacts, and sea-level changes associated with dynamic ice sheets and for quantifying the uncertainty in ice-sheet-sourced global sea-level change.

  5. An International Marine-Atmospheric 222Rn Measurement Intercomparison in Bermuda Part I: NIST Calibration and Methodology for Standardized Sample Additions

    PubMed Central

    Collé, R.; Unterweger, M. P.; Hodge, P. A.; Hutchinson, J. M. R.

    1996-01-01

    As part of an international 222Rn measurement intercomparison conducted at Bermuda in October 1991, NIST provided standardized sample additions of known, but undisclosed (“blind”) 222Rn concentrations that could be related to U.S. national standards. The standardized sample additions were obtained with a calibrated 226Ra source and a specially-designed manifold used to obtain well-known dilution factors from simultaneous flow-rate measurements. The additions were introduced over sampling periods of several hours (typically 4 h) into a common streamline on a sampling tower used by the participating laboratories for their measurements. The standardized 222Rn activity concentrations for the intercomparison ranged from approximately 2.5 Bq · m−3 to 35 Bq · m−3 (of which the lower end of this range approached concentration levels for ambient Bermudian air) and had overall uncertainties, approximating a 3 standard deviation uncertainty interval, of about 6 % to 13 %. This paper describes the calibration and methodology for the standardized sample additions. PMID:27805090

  6. Urine Anion Gap to Predict Urine Ammonium and Related Outcomes in Kidney Disease.

    PubMed

    Raphael, Kalani L; Gilligan, Sarah; Ix, Joachim H

    2018-02-07

    Low urine ammonium excretion is associated with ESRD in CKD. Few laboratories measure urine ammonium, limiting clinical application. We determined correlations between urine ammonium, the standard urine anion gap, and a modified urine anion gap that includes sulfate and phosphate and compared risks of ESRD or death between these ammonium estimates and directly measured ammonium. We measured ammonium, sodium, potassium, chloride, phosphate, and sulfate from baseline 24-hour urine collections in 1044 African-American Study of Kidney Disease and Hypertension participants. We evaluated the cross-sectional correlations between urine ammonium, the standard urine anion gap (sodium + potassium - chloride), and a modified urine anion gap that includes urine phosphate and sulfate in the calculation. Multivariable-adjusted Cox models determined the associations of the standard urine anion gap and the modified urine anion gap with the composite end point of death or ESRD; these results were compared with results using urine ammonium as the predictor of interest. The standard urine anion gap had a weak and direct correlation with urine ammonium ( r =0.18), whereas the modified urine anion gap had a modest inverse relationship with urine ammonium ( r =-0.58). Compared with the highest tertile of urine ammonium, those in the lowest urine ammonium tertile had higher risk of ESRD or death (hazard ratio, 1.46; 95% confidence interval, 1.13 to 1.87) after adjusting for demographics, GFR, proteinuria, and other confounders. In comparison, participants in the corresponding standard urine anion gap tertile did not have higher risk of ESRD or death (hazard ratio, 0.82; 95% confidence interval, 0.64 to 1.07), whereas the risk for those in the corresponding modified urine anion gap tertile (hazard ratio, 1.32; 95% confidence interval, 1.03 to 1.68) approximated that of directly measured urine ammonium. Urine anion gap is a poor surrogate of urine ammonium in CKD unless phosphate and sulfate are included in the calculation. Because the modified urine anion gap merely estimates urine ammonium and requires five measurements, direct measurements of urine ammonium are preferable in CKD. Copyright © 2018 by the American Society of Nephrology.

  7. Soundings from SGP, June 2014 Sonde Comparison Study

    DOE Data Explorer

    Jensen, Michael

    2015-03-06

    In early June 2014, a radiosonde intercomparison trial was undertaken at the SGP Central Facility site with the goal of quantifying the relative performance of the RS92-SGP/MW31 and RS41-SG/MW41 radiosondes/systems. The June time period at SGP represents a springtime mid-latitude convective environment where the extensive remote sensing observations at the SGP site were used to further quantify the environment during the intercomparison. Over the course of five days (3 - 8 June) a total of 20 balloon launches were completed with efforts to sample the entire diurnal cycle and a variety of cloud conditions

  8. Dose evaluation in criticality accidents using response of Panasonic TL personal dosemeters (UD-809/UD-802).

    PubMed

    Zeyrek, C T; Gündüz, H

    2012-09-01

    This study gives the results of dosimetry measurements carried out in the Silène reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silène experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together.

  9. Inter-comparison of boron concentration measurements at INFN-University of Pavia (Italy) and CNEA (Argentina).

    PubMed

    Portu, Agustina; Postuma, Ian; Gadan, Mario Alberto; Saint Martin, Gisela; Olivera, María Silvina; Altieri, Saverio; Protti, Nicoletta; Bortolussi, Silva

    2015-11-01

    An inter-comparison of three boron determination techniques was carried out between laboratories from INFN-University of Pavia (Italy) and CNEA (Argentina): alpha spectrometry (alpha-spect), neutron capture radiography (NCR) and quantitative autoradiography (QTA). Samples of different nature were analysed: liquid standards, liver homogenates and tissue samples from different treatment protocols. The techniques showed a good agreement in a concentration range of interest in BNCT (1-100ppm), thus demonstrating their applicability as precise methods to quantify boron and determine its distribution in tissues. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. International Intercomparison of Regular Transmittance Scales

    NASA Astrophysics Data System (ADS)

    Eckerle, K. L.; Sutter, E.; Freeman, G. H. C.; Andor, G.; Fillinger, L.

    1990-01-01

    An intercomparison of the regular spectral transmittance scales of NIST, Gaithersburg, MD (USA); PTB, Braunschweig (FRG); NPL, Teddington, Middlesex (UK); and OMH, Budapest (H) was accomplished using three sets of neutral glass filters with transmittances ranging from approximately 0.92 to 0.001. The difference between the results from the reference spectrophotometers of the laboratories was generally smaller than the total uncertainty of the interchange. The relative total uncertainty ranges from 0.05% to 0.75% for transmittances from 0.92 to 0.001. The sample-induced error was large - contributing 40% or more of the total except in a few cases.

  11. Soil sampling strategies: evaluation of different approaches.

    PubMed

    de Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Mufato, Renzo; Sartori, Giuseppe; Stocchero, Giulia

    2008-11-01

    The National Environmental Protection Agency of Italy (APAT) performed a soil sampling intercomparison, inviting 14 regional agencies to test their own soil sampling strategies. The intercomparison was carried out at a reference site, previously characterised for metal mass fraction distribution. A wide range of sampling strategies, in terms of sampling patterns, type and number of samples collected, were used to assess the mean mass fraction values of some selected elements. The different strategies led in general to acceptable bias values (D) less than 2sigma, calculated according to ISO 13258. Sampling on arable land was relatively easy, with comparable results between different sampling strategies.

  12. Myoglobin urine test

    MedlinePlus

    Urine myoglobin; Heart attack - myoglobin urine test; Myositis - myoglobin urine test; Rhabdomyolysis - myoglobin urine test ... The test involves only normal urination, which should cause no discomfort.

  13. Urine osmolality in the US population: Implications for environmental biomonitoring

    PubMed Central

    Yeh, Hung-Chieh; Lin, Yu-Sheng; Kuo, Chin-Chi; Weidemann, Darcy; Weaver, Virginia; Fadrowski, Jeffrey; Neu, Alicia; Navas-Acien, Ana

    2018-01-01

    Background For many environmental chemicals, concentrations in spot urine samples are considered valid surrogates of exposure and internal dose. To correct for urine dilution, spot urine concentrations are commonly adjusted for urinary creatinine. There are, however, several concerns about the use of urine creatinine. While urine osmolality is an attractive alternative; its characteristics and determinants in the general population remain unknown. Our objective was to describe the determinants of urine osmolality and to contrast the difference between osmolality and creatinine in urine. Methods From the National Health and Nutrition Examination Survey (NHANES) 2009–2012, 10,769 participants aged 16 years or older with measured urine osmolality and creatinine were used in the analysis. Very dilute and very concentrated urine was defined as urine creatinine lower than 0.3 g/l and higher than 3 g/l, respectively. Linear and logistic regression analyses were performed to investigate the associations of interest. Results Urine osmolality and creatinine were highly correlated (Pearson correlation coefficient = 0.75) and their respective median values were 648 mOsm/kg and 1.07 g/l. The prevalence of very dilute and very concentrated urine samples was 8.1% and 3.1%, respectively. Factors associated in the same direction with both urine osmolality and urine creatinine included age, sex, race, body mass index (BMI), hypertension, water intake, and blood osmolality. The magnitude of associations expressed as percent change was significantly stronger with creatinine than osmolality. Compared to urine creatinine, urine osmolality did not vary by diabetes status but was affected by daily total protein intake. Participants with chronic kidney disease (CKD) had significantly higher urine creatinine concentrations but lower urine osmolality. Both very dilute and concentrated urine were associated with a diverse array of sociodemographic, medical conditions, and dietary factors. For instance, females were approximately 3.3 times more likely to have urine over-dilution than male [the adjusted odds ratios (95% CI) = 3.27 (2.10–5.10)]. Conclusion Although the determinants of urine osmolality were generally similar to those of urine creatinine, the relative influence of socio-demographic and medical conditions was less on urine osmolality than on urine creatinine. Protocols for spot urine sample collection could recommend avoiding excessive and insufficient water intake before urine sampling to improve urine adequacy. The feasibility of adopting urine osmolality adjustment and water intake recommendations before providing spot urine samples for environmental biomonitoring merits further investigation. PMID:25460670

  14. GMMIP (v1.0) contribution to CMIP6: Global Monsoons Model Inter-comparison Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Tianjun; Turner, Andrew G.; Kinter, James L.

    The Global Monsoons Model Inter-comparison Project (GMMIP) has been endorsed by the panel of Coupled Model Inter-comparison Project (CMIP) as one of the participating model inter-comparison projects (MIPs) in the sixth phase of CMIP (CMIP6). The focus of GMMIP is on monsoon climatology, variability, prediction and projection, which is relevant to four of the “Grand Challenges” proposed by the World Climate Research Programme. At present, 21 international modeling groups are committed to joining GMMIP. This overview paper introduces the motivation behind GMMIP and the scientific questions it intends to answer. Three tiers of experiments, of decreasing priority, are designed to examinemore » (a) model skill in simulating the climatology and interannual-to-multidecadal variability of global monsoons forced by the sea surface temperature during historical climate period; (b) the roles of the Interdecadal Pacific Oscillation and Atlantic Multidecadal Oscillation in driving variations of the global and regional monsoons; and (c) the effects of large orographic terrain on the establishment of the monsoons. The outputs of the CMIP6 Diagnostic, Evaluation and Characterization of Klima experiments (DECK), “historical” simulation and endorsed MIPs will also be used in the diagnostic analysis of GMMIP to give a comprehensive understanding of the roles played by different external forcings, potential improvements in the simulation of monsoon rainfall at high resolution and reproducibility at decadal timescales. The implementation of GMMIP will improve our understanding of the fundamental physics of changes in the global and regional monsoons over the past 140 years and ultimately benefit monsoons prediction and projection in the current century.« less

  15. Dosimetry audits and intercomparisons in radiotherapy: A Malaysian profile

    NASA Astrophysics Data System (ADS)

    M. Noor, Noramaliza; Nisbet, A.; Hussein, M.; Chu S, Sarene; Kadni, T.; Abdullah, N.; Bradley, D. A.

    2017-11-01

    Quality audits and intercomparisons are important in ensuring control of processes in any system of endeavour. Present interest is in control of dosimetry in teletherapy, there being a need to assess the extent to which there is consistent radiation dose delivery to the patient. In this study we review significant factors that impact upon radiotherapy dosimetry, focusing upon the example situation of radiotherapy delivery in Malaysia, examining existing literature in support of such efforts. A number of recommendations are made to provide for increased quality assurance and control. In addition to this study, the first level of intercomparison audit i.e. measuring beam output under reference conditions at eight selected Malaysian radiotherapy centres is checked; use being made of 9 μm core diameter Ge-doped silica fibres (Ge-9 μm). The results of Malaysian Secondary Standard Dosimetry Laboratory (SSDL) participation in the IAEA/WHO TLD postal dose audit services during the period between 2011 and 2015 will also been discussed. In conclusion, following review of the development of dosimetry audits and the conduct of one such exercise in Malaysia, it is apparent that regular periodic radiotherapy audits and intercomparison programmes should be strongly supported and implemented worldwide. The programmes to-date demonstrate these to be a good indicator of errors and of consistency between centres. A total of ei+ght beams have been checked in eight Malaysian radiotherapy centres. One out of the eight beams checked produced an unacceptable deviation; this was found to be due to unfamiliarity with the irradiation procedures. Prior to a repeat measurement, the mean ratio of measured to quoted dose was found to be 0.99 with standard deviation of 3%. Subsequent to the repeat measurement, the mean distribution was 1.00, and the standard deviation was 1.3%.

  16. Intercomparison of mid latitude storm diagnostics (IMILAST) - synthesis of project results

    NASA Astrophysics Data System (ADS)

    Neu, Urs

    2017-04-01

    The analysis of the occurrence of mid-latitude storms is of great socio-economical interest due to their vast and destructive impacts. However, a unique definition of cyclones is missing, and therefore the definition of what a cyclone is as well as quantifying its strength contains subjective choices. Existing automatic cyclone identification and tracking algorithms are based on different definitions and use diverse characteristics, e.g. data transformation, metrics used for cyclone identification, cyclone identification procedures or tracking methods. The project IMILAST systematically compares different cyclone detection and tracking methods, with the aim to comprehensively assess the influence of different algorithms on cyclone climatologies, temporal trends of frequency, strength or other characteristics of cyclones and thus quantify systematic uncertainties in mid-latitudinal storm identification and tracking. The three main intercomparison experiments used the ERA-interim reanalysis as a common input data set and focused on differences between the methods with respect to number, track density, life cycle characteristics, and trend patterns on the one hand and potential differences of the long-term climate change signal of cyclonic activity between the methods on the other hand. For the third experiment, the intercomparison period has been extended to a 30 year period from 1979 to 2009 and focuses on more specific aspects, such as parameter sensitivities, the comparison of automated to manual tracking sets, regional analysis (regional trends, Arctic and Antarctic cyclones, cyclones in the Mediterranean) or specific phenomena like splitting and merging of cyclones. In addition, the representation of storms and their characteristics in reanalysis data sets is examined to further enhance the knowledge on uncertainties related to storm occurrence. This poster presents a synthesis of the main results from the intercomparison activities within IMILAST.

  17. Global Intercomparison of 12 Land Surface Heat Flux Estimates

    NASA Technical Reports Server (NTRS)

    Jimenez, C.; Prigent, C.; Mueller, B.; Seneviratne, S. I.; McCabe, M. F.; Wood, E. F.; Rossow, W. B.; Balsamo, G.; Betts, A. K.; Dirmeyer, P. A.; hide

    2011-01-01

    A global intercomparison of 12 monthly mean land surface heat flux products for the period 1993-1995 is presented. The intercomparison includes some of the first emerging global satellite-based products (developed at Paris Observatory, Max Planck Institute for Biogeochemistry, University of California Berkeley, University of Maryland, and Princeton University) and examples of fluxes produced by reanalyses (ERA-Interim, MERRA, NCEP-DOE) and off-line land surface models (GSWP-2, GLDAS CLM/ Mosaic/Noah). An intercomparison of the global latent heat flux (Q(sub le)) annual means shows a spread of approx 20 W/sq m (all-product global average of approx 45 W/sq m). A similar spread is observed for the sensible (Q(sub h)) and net radiative (R(sub n)) fluxes. In general, the products correlate well with each other, helped by the large seasonal variability and common forcing data for some of the products. Expected spatial distributions related to the major climatic regimes and geographical features are reproduced by all products. Nevertheless, large Q(sub le)and Q(sub h) absolute differences are also observed. The fluxes were spatially averaged for 10 vegetation classes. The larger Q(sub le) differences were observed for the rain forest but, when normalized by mean fluxes, the differences were comparable to other classes. In general, the correlations between Q(sub le) and R(sub n) were higher for the satellite-based products compared with the reanalyses and off-line models. The fluxes were also averaged for 10 selected basins. The seasonality was generally well captured by all products, but large differences in the flux partitioning were observed for some products and basins.

  18. IPRT polarized radiative transfer model intercomparison project - Three-dimensional test cases (phase B)

    NASA Astrophysics Data System (ADS)

    Emde, Claudia; Barlakas, Vasileios; Cornet, Céline; Evans, Frank; Wang, Zhen; Labonotte, Laurent C.; Macke, Andreas; Mayer, Bernhard; Wendisch, Manfred

    2018-04-01

    Initially unpolarized solar radiation becomes polarized by scattering in the Earth's atmosphere. In particular molecular scattering (Rayleigh scattering) polarizes electromagnetic radiation, but also scattering of radiation at aerosols, cloud droplets (Mie scattering) and ice crystals polarizes. Each atmospheric constituent produces a characteristic polarization signal, thus spectro-polarimetric measurements are frequently employed for remote sensing of aerosol and cloud properties. Retrieval algorithms require efficient radiative transfer models. Usually, these apply the plane-parallel approximation (PPA), assuming that the atmosphere consists of horizontally homogeneous layers. This allows to solve the vector radiative transfer equation (VRTE) efficiently. For remote sensing applications, the radiance is considered constant over the instantaneous field-of-view of the instrument and each sensor element is treated independently in plane-parallel approximation, neglecting horizontal radiation transport between adjacent pixels (Independent Pixel Approximation, IPA). In order to estimate the errors due to the IPA approximation, three-dimensional (3D) vector radiative transfer models are required. So far, only a few such models exist. Therefore, the International Polarized Radiative Transfer (IPRT) working group of the International Radiation Commission (IRC) has initiated a model intercomparison project in order to provide benchmark results for polarized radiative transfer. The group has already performed an intercomparison for one-dimensional (1D) multi-layer test cases [phase A, 1]. This paper presents the continuation of the intercomparison project (phase B) for 2D and 3D test cases: a step cloud, a cubic cloud, and a more realistic scenario including a 3D cloud field generated by a Large Eddy Simulation (LES) model and typical background aerosols. The commonly established benchmark results for 3D polarized radiative transfer are available at the IPRT website (http://www.meteo.physik.uni-muenchen.de/ iprt).

  19. Elemental composition of ambient aerosols measured with high temporal resolution using an online XRF spectrometer

    NASA Astrophysics Data System (ADS)

    Furger, Markus; Cruz Minguillón, María; Yadav, Varun; Slowik, Jay G.; Hüglin, Christoph; Fröhlich, Roman; Petterson, Krag; Baltensperger, Urs; Prévôt, André S. H.

    2017-06-01

    The Xact 625 Ambient Metals Monitor was tested during a 3-week field campaign at the rural, traffic-influenced site Härkingen in Switzerland during the summer of 2015. The field campaign encompassed the Swiss National Day fireworks event, providing increased concentrations and unique chemical signatures compared to non-fireworks (or background) periods. The objective was to evaluate the data quality by intercomparison with other independent measurements and test its applicability for aerosol source quantification. The Xact was configured to measure 24 elements in PM10 with 1 h time resolution. Data quality was evaluated for 10 24 h averages of Xact data by intercomparison with 24 h PM10 filter data analysed with ICP-OES for major elements, ICP-MS for trace elements, and gold amalgamation atomic absorption spectrometry for Hg. Ten elements (S, K, Ca, Ti, Mn, Fe, Cu, Zn, Ba, Pb) showed excellent correlation between the compared methods, with r2 values ≥ 0.95. However, the slopes of the regressions between Xact 625 and ICP data varied from 0.97 to 1.8 (average 1.28) and thus indicated generally higher Xact elemental concentrations than ICP for these elements. Possible reasons for these differences are discussed, but further investigations are needed. For the remaining elements no conclusions could be drawn about their quantification for various reasons, mainly detection limit issues. An indirect intercomparison of hourly values was performed for the fireworks peak, which brought good agreement of total masses when the Xact data were corrected with the regressions from the 24 h value intercomparison. The results demonstrate that multi-metal characterization at high-time-resolution capability of Xact is a valuable and practical tool for ambient monitoring.

  20. WCRP Task Team for the Intercomparison of Reanalyses (TIRA): Motivation and Progress

    NASA Technical Reports Server (NTRS)

    Bosilovich, Michael

    2017-01-01

    Reanalyses have proven to be an important resource for weather and climate related research, as well as societal applications at large. Several centers have emerged to produce new atmospheric reanalyses in various forms every few years. In addition, land and ocean communities are producing disciplinary uncoupled reanalyses. Current research and development in reanalysis is directed at (1) extending the length of reanalyzed period and (2) use of coupled Earth system models for climate reanalysis. While WCRPs involvement in the reanalyses communities through its Data Advisory Council (WDAC) has been substantial, for example in organizing international conferences on reanalyses, a central team of reanalyses expertise is not in place in the WCRP structure. The differences among reanalyses and their inherent uncertainties are some of the most important questions for both users and developers of reanalyses. Therefore, a collaborative effort to systematically assess and intercompare reanalyses would be a logical progression that fills the needs of the community and contributes to the WCRP mission. The primary charge to the TIRA is to develop a reanalysis intercomparison project plan that will attain the following objectives.1)To foster understanding and estimation of uncertainties in reanalysis data by intercomparison and other means 2)To communicate new developments and best practices among the reanalyses producing centers 3)To enhance the understanding of data and assimilation issues and their impact on uncertainties, leading to improved reanalyses for climate assessment 4)To communicate the strengths and weaknesses of reanalyses, their fitness for purpose, and best practices in the use of reanalysis datasets by the scientific community. This presentation outlines the need for a task team on reanalyses, their intercomparison, the objectives of the team and progress thus far.

  1. Ketones urine test

    MedlinePlus

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  2. An analysis of dependency of counting efficiency on worker anatomy for in vivo measurements: whole-body counting

    NASA Astrophysics Data System (ADS)

    Zhang, Binquan; Mille, Matthew; Xu, X. George

    2008-07-01

    In vivo radiobioassay is integral to many health physics and radiological protection programs dealing with internal exposures. The Bottle Manikin Absorber (BOMAB) physical phantom has been widely used for whole-body counting calibrations. However, the shape of BOMAB phantoms—a collection of plastic, cylindrical shells which contain no bones or internal organs—does not represent realistic human anatomy. Furthermore, workers who come in contact with radioactive materials have rather different body shape and size. To date, there is a lack of understanding about how the counting efficiency would change when the calibrated counter is applied to a worker with complicated internal organs or tissues. This paper presents a study on various in vivo counting efficiencies obtained from Monte Carlo simulations of two BOMAB phantoms and three tomographic image-based models (VIP-Man, NORMAN and CNMAN) for a scenario involving homogeneous whole-body radioactivity contamination. The results reveal that a phantom's counting efficiency is strongly dependent on the shape and size of a phantom. Contrary to what was expected, it was found that only small differences in efficiency were observed when the density and material composition of all internal organs and tissues of the tomographic phantoms were changed to water. The results of this study indicate that BOMAB phantoms with appropriately adjusted size and shape can be sufficient for whole-body counting calibrations when the internal contamination is homogeneous.

  3. Immunoelectrophoresis - urine

    MedlinePlus

    Immunoglobulin electrophoresis - urine; Gamma globulin electrophoresis - urine; Urine immunoglobulin electrophoresis; IEP - urine ... A clean-catch urine sample is needed. The clean-catch method is used to prevent germs from the penis or vagina from getting ...

  4. Correlation of Urine Biomarkers: Microalbuminuria and Spot Urine Protein among Diabetic Patients. Application of Spot Urine Protein in Diabetic Kidney Disease, Nephropathy, Proteinuria Estimation, Diagnosing and Monitoring.

    PubMed

    Aziz, Kamran M A

    2015-01-01

    Current study has invented a new method for utilizing spot urine protein among diabetic patients. There have been various efforts and strategies in research internationally to detect, diagnose and monitor nephropathy/DKD. Although 24-hour urine studies are gold standard, however, there exist some controversies about microalbuminuria and spot urine protein. The current study was designed to utilize spot urine protein among diabetic patients and to find its association with routine dipstick urine test for albumin, and microalbuminuria. The study demonstrated significant association of spot urine protein with urine dipstick albumin, and has demonstrated increasing spot urine protein with increasing albumin in urine (p-value < 0.0001). This study also demonstrated significantly higher levels of spot urine protein between the groups with nephropathy/DKD as compared to those without nephropathy/DKD (p-value < 0.0001). Similarly, spot urine protein and spot urine protein/creatinine were also significantly associated with microalbumin and microalbumin/creatinine in urine. Significant regression models for spot urine protein and microalbuminuria were also developed and proposed to detect and estimate microalbumin in urine while utilizing spot urine protein (< 0.0001). Synthesized regression equations and models can be used confidently to detect, rule out and monitor proteinuria and DKD. ROC curves were utilized to detect spot urine protein cutoff points for nephropathy and DKD with high specificity and sensitivity. Some important patents were also discussed in the paper regarding albuminuria/proteinuria detection and management. Current study has demonstrated and concluded, for the first time, that there exists a significant association of spot urine protein with routine dipstick albumin in urine and microalbuminuria. It is also essential to detect early, monitor and manage proteinuria, hypertension and dyslipidemia with good glycemic control to prevent diabetes complications.

  5. HCG in urine

    MedlinePlus

    Beta-HCG - urine; Human chorionic gonadotropin - urine; Pregnancy test - hCG in urine ... To collect a urine sample, you urinate into a special (sterile) cup. Home pregnancy tests require the test strip to be dipped into ...

  6. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    PubMed Central

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. Conclusions The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease. PMID:26353117

  7. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    PubMed

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.

  8. The Latest SORCE Solar Spectral Irradiance Data Release: Inter-Comparison and a First Look at TSIS SIM Measurement.

    NASA Astrophysics Data System (ADS)

    Beland, S.; Sandoval, L.; Vanier, B.; Elliott, J.; Harder, J. W.; Snow, M. A.; Woods, T. N.; Richard, E. C.; Pilewskie, P.

    2017-12-01

    The Spectral Irradiance Monitor (SIM), the SOLar STellar Irradiance Comparison Experiment (SOLSTICE), and the XUV Photometer System (XPS) instruments on board the Solar Radiation and Climate Experiment (SORCE) mission have been taking daily Solar spectral irradiance (SSI) measurements since April 2003. We present the latest data releases from these instruments, describing the improvements in the new datasets and the trends measured during Solar cycles 23 and 24. An inter-comparison of the SSI over the overlapping wavelengths for SIM and SOLSTICE is presented as well as, if the data is available, a comparison with the first light measurements from TSIS-SIM.

  9. Ozone Response to Aircraft Emissions: Sensitivity Studies with Two-dimensional Models

    NASA Technical Reports Server (NTRS)

    Ko, Malcolm K. W.; Weisenstein, Debra; Jackman, Charles H.; Douglass, Anne R.; Bureske, K.; Weubbles, Donald J.; Kinnison, Douglas E.; Brasseur, G.; Pyle, J.; Jones, Anna

    1992-01-01

    Our first intercomparison/assessment of the effects of a proposed high-speed civil transport (HSCT) fleet on the stratosphere is presented. These model calculations should be considered more as sensitivity studies, primarily designed to serve the following purposes: (1) to allow for intercomparison of model predictions; (2) to focus on the range of fleet operations and engine specifications giving minimal environmental impact; and (3) to provide the basis for future assessment studies. The basic scenarios were chosen to be as realistic as possible, using the information available on anticipated developments in technology. They are not to be interpreted as a commitment or goal for environmental acceptability.

  10. NASA Giovanni Portals for NLDAS/GLDAS Online Visualization, Analysis, and Intercomparison

    NASA Technical Reports Server (NTRS)

    Rui, Hualan; Teng, William L.; Vollmer, Bruce; Mocko, David M.; Beaudoing, Hiroko Kato; Rodell, Matthew

    2011-01-01

    The North American Land Data Assimilation System (NLDAS) and Global Land Data Assimilation System (GLDAS) are generating a series of land surface forcing (e.g., precipitation, surface meteorology, and radiation), state (e.g., soil moisture and temperature, and snow), and flux (e.g., evaporation and sensible heat flux) products, simulated by several land surface models. To date, NLDAS and GLDAS have generated more than 30 (1979 - present) and 60 (1948 - present) years of data, respectively. To further facilitate data accessibility and utilization, three new portals in the NASA Giovanni system have been made available for NLDAS and GLDAS online visualization, analysis, and intercomparison.

  11. Ozone profile intercomparison based on simultaneous observations between 20 and 40 km

    NASA Technical Reports Server (NTRS)

    Aimedieu, P.; Krueger, A. J.; Robbins, D. E.; Simon, P. C.

    1983-01-01

    The vertical distribution of stratospheric ozone has been simultaneously measured by means of five different instruments carried on the same balloon payload. The launches were performed from Gap during the intercomparison campaign conducted in June 1981 in southern France. Data obtained between altitudes of 20 and 40 km are compared and discussed. Vertical profiles deduced from Electrochemical Concentration Cell sondes launched from the same location by small balloons and from short Umkehr measurements made at Mt Chiran (France) are also included in this comparison. Systematic differences of the order of 20 percent between ozone profiles deduced from solar u.v. absorption and in situ techniques are found.

  12. Impact of Spatial Scales on the Intercomparison of Climate Scenarios

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Wei; Steptoe, Michael; Chang, Zheng

    2017-01-01

    Scenario analysis has been widely applied in climate science to understand the impact of climate change on the future human environment, but intercomparison and similarity analysis of different climate scenarios based on multiple simulation runs remain challenging. Although spatial heterogeneity plays a key role in modeling climate and human systems, little research has been performed to understand the impact of spatial variations and scales on similarity analysis of climate scenarios. To address this issue, the authors developed a geovisual analytics framework that lets users perform similarity analysis of climate scenarios from the Global Change Assessment Model (GCAM) using a hierarchicalmore » clustering approach.« less

  13. Past and future weather-induced risk in crop production

    NASA Astrophysics Data System (ADS)

    Elliott, J. W.; Glotter, M.; Russo, T. A.; Sahoo, S.; Foster, I.; Benton, T.; Mueller, C.

    2016-12-01

    Drought-induced agricultural loss is one of the most costly impacts of extreme weather and may harm more people than any other consequence of climate change. Improvements in farming practices have dramatically increased crop productivity, but yields today are still tightly linked to climate variation. We report here on a number of recent studies evaluating extreme event risk and impacts under historical and near future conditions, including studies conducted as part of the Agricultural Modeling Intercomparison and Improvement Project (AgMIP), the Inter-Sectoral Impacts Model Intercomparison Project (ISI-MIP) and the UK-US Taskforce on Extreme Weather and Global Food System Resilience.

  14. The Agricultural Model Intercomparison and Improvement Project: Phase I Activities by a Global Community of Science. Chapter 1

    NASA Technical Reports Server (NTRS)

    Rosenzweig, Cynthia E.; Jones, James W.; Hatfield, Jerry L.; Antle, John M.; Ruane, Alexander C.; Mutter, Carolyn Z.

    2015-01-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) was founded in 2010. Its mission is to improve substantially the characterization of world food security as affected by climate variability and change, and to enhance adaptation capacity in both developing and developed countries. The objectives of AgMIP are to: Incorporate state-of-the-art climate, crop/livestock, and agricultural economic model improvements into coordinated multi-model regional and global assessments of future climate impacts and adaptation and other key aspects of the food system. Utilize multiple models, scenarios, locations, crops/livestock, and participants to explore uncertainty and the impact of data and methodological choices. Collaborate with regional experts in agronomy, animal sciences, economics, and climate to build a strong basis for model applications, addressing key climate related questions and sustainable intensification farming systems. Improve scientific and adaptive capacity in modeling for major agricultural regions in the developing and developed world, with a focus on vulnerable regions. Improve agricultural data and enhance data-sharing based on their intercomparison and evaluation using best scientific practices. Develop modeling frameworks to identify and evaluate promising adaptation technologies and policies and to prioritize strategies.

  15. Constraints and potentials of future irrigation water availability on agricultural production under climate change.

    PubMed

    Elliott, Joshua; Deryng, Delphine; Müller, Christoph; Frieler, Katja; Konzmann, Markus; Gerten, Dieter; Glotter, Michael; Flörke, Martina; Wada, Yoshihide; Best, Neil; Eisner, Stephanie; Fekete, Balázs M; Folberth, Christian; Foster, Ian; Gosling, Simon N; Haddeland, Ingjerd; Khabarov, Nikolay; Ludwig, Fulco; Masaki, Yoshimitsu; Olin, Stefan; Rosenzweig, Cynthia; Ruane, Alex C; Satoh, Yusuke; Schmid, Erwin; Stacke, Tobias; Tang, Qiuhong; Wisser, Dominik

    2014-03-04

    We compare ensembles of water supply and demand projections from 10 global hydrological models and six global gridded crop models. These are produced as part of the Inter-Sectoral Impacts Model Intercomparison Project, with coordination from the Agricultural Model Intercomparison and Improvement Project, and driven by outputs of general circulation models run under representative concentration pathway 8.5 as part of the Fifth Coupled Model Intercomparison Project. Models project that direct climate impacts to maize, soybean, wheat, and rice involve losses of 400-1,400 Pcal (8-24% of present-day total) when CO2 fertilization effects are accounted for or 1,400-2,600 Pcal (24-43%) otherwise. Freshwater limitations in some irrigated regions (western United States; China; and West, South, and Central Asia) could necessitate the reversion of 20-60 Mha of cropland from irrigated to rainfed management by end-of-century, and a further loss of 600-2,900 Pcal of food production. In other regions (northern/eastern United States, parts of South America, much of Europe, and South East Asia) surplus water supply could in principle support a net increase in irrigation, although substantial investments in irrigation infrastructure would be required.

  16. Airborne intercomparison of nitric oxide measurement techniques

    NASA Technical Reports Server (NTRS)

    Hoell, James M., Jr.; Gregory, Gerald L.; Mcdougal, David S.; Torres, Arnold L.; Davis, Douglas D.

    1987-01-01

    Results from an airborne intercomparison of techniques to measure tropospheric levels of nitric oxide (NO) are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted during missions flown in the fall of 1983 and spring of 1984. Instruments intercompared included a laser-induced fluorescence (LIF) system and two chemiluminescence instruments (CL). NO mixing ratios from below 5 pptv (parts per trillion by volume) to greater than 100 pptv were reported, with the majority less than 20 pptv. Good correlation was observed between the measurements reported by the CL and LIF techniques. The general level of agreement observed for the ensemble of measurements obtained during the two missions provides the basis from which one can conclude that equally 'valid' measurements of background levels of NO can be expected from either CL or LIF instruments. At the same time the periods of disagreement that were observed between the CL and LIF instruments as well as between the two CL instruments highlight the difficulty of obtaining reliable measurements with NO mixing ratios in the 5-20 pptv range and emphasize the vigilance that should be maintained in future NO measurements.

  17. Nuclear accident dosimetry intercomparison studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sims, C.S.

    1989-09-01

    Twenty-two nuclear accident dosimetry intercomparison studies utilizing the fast-pulse Health Physics Research Reactor at the Oak Ridge National Laboratory have been conducted since 1965. These studies have provided a total of 62 different organizations a forum for discussion of criticality accident dosimetry, an opportunity to test their neutron and gamma-ray dosimetry systems under a variety of simulated criticality accident conditions, and the experience of comparing results with reference dose values as well as with the measured results obtained by others making measurements under identical conditions. Sixty-nine nuclear accidents (27 with unmoderated neutron energy spectra and 42 with eight different shieldedmore » spectra) have been simulated in the studies. Neutron doses were in the 0.2-8.5 Gy range and gamma doses in the 0.1-2.0 Gy range. A total of 2,289 dose measurements (1,311 neutron, 978 gamma) were made during the intercomparisons. The primary methods of neutron dosimetry were activation foils, thermoluminescent dosimeters, and blood sodium activation. The main methods of gamma dose measurement were thermoluminescent dosimeters, radiophotoluminescent glass, and film. About 68% of the neutron measurements met the accuracy guidelines (+/- 25%) and about 52% of the gamma measurements met the accuracy criterion (+/- 20%) for accident dosimetry.« less

  18. Economic impacts of climate change on agriculture: the AgMIP approach

    NASA Astrophysics Data System (ADS)

    Delincé, Jacques; Ciaian, Pavel; Witzke, Heinz-Peter

    2015-01-01

    The current paper investigates the long-term global impacts on crop productivity under different climate scenarios using the AgMIP approach (Agricultural Model Intercomparison and Improvement Project). The paper provides horizontal model intercomparison from 11 economic models as well as a more detailed analysis of the simulated effects from the Common Agricultural Policy Regionalized Impact (CAPRI) model to systematically compare its performance with other AgMIP models and specifically for the Chinese agriculture. CAPRI is a comparative static partial equilibrium model extensively used for medium and long-term economic and environmental policy impact applications. The results indicate that, at the global level, the climate change will cause an agricultural productivity decrease (between -2% and -15% by 2050), a food price increase (between 1.3% and 56%) and an expansion of cultivated area (between 1% and 4%) by 2050. The results for China indicate that the climate change effects tend to be smaller than the global impacts. The CAPRI-simulated effects are, in general, close to the median across all AgMIP models. Model intercomparison analyses reveal consistency in terms of direction of change to climate change but relatively strong heterogeneity in the magnitude of the effects between models.

  19. Long History of IAM Comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Steven J.; Clarke, Leon E.; Edmonds, James A.

    2015-04-23

    Correspondence to editor: We agree with the editors that the assumptions behind models of all types, including integrated assessment models (IAMs), should be as transparent as possible. The editors were in error, however, when they implied that the IAM community is just “now emulating the efforts of climate researchers by instigating their own model inter-comparison projects (MIPs).” In fact, model comparisons for integrated assessment and climate models followed a remarkably similar trajectory. Early General Circulation Model (GCM) comparison efforts, evolved to the first Atmospheric Model Inter-comparison Project (AMIP), which was initiated in the early 1990s. Atmospheric models evolved to coupledmore » atmosphere-ocean models (AOGCMs) and results from the first Coupled Model Inter-Comparison Project (CMIP1) become available about a decade later. Results of first energy model comparison exercise, conducted under the auspices of the Stanford Energy Modeling Forum, were published in 1977. A summary of the first comparison focused on climate change was published in 1993. As energy models were coupled to simple economic and climate models to form IAMs, the first comparison exercise for IAMs (EMF-14) was initiated in 1994, and IAM comparison exercises have been on-going since this time.« less

  20. The Geoengineering Model Intercomparison Project Phase 6 (GeoMIP6): Simulation design and preliminary results

    DOE PAGES

    Kravitz, Benjamin S.; Robock, Alan; Tilmes, S.; ...

    2015-10-27

    We present a suite of new climate model experiment designs for the Geoengineering Model Intercomparison Project (GeoMIP). This set of experiments, named GeoMIP6 (to be consistent with the Coupled Model Intercomparison Project Phase 6), builds on the previous GeoMIP project simulations, and has been expanded to address several further important topics, including key uncertainties in extreme events, the use of geoengineering as part of a portfolio of responses to climate change, and the relatively new idea of cirrus cloud thinning to allow more long wave radiation to escape to space. We discuss experiment designs, as well as the rationale formore » those designs, showing preliminary results from individual models when available. We also introduce a new feature, called the GeoMIP Testbed, which provides a platform for simulations that will be performed with a few models and subsequently assessed to determine whether the proposed experiment designs will be adopted as core (Tier 1) GeoMIP experiments. In conclusion, this is meant to encourage various stakeholders to propose new targeted experiments that address their key open science questions, with the goal of making GeoMIP more relevant to a broader set of communities.« less

  1. Models and Measurements Intercomparison 2

    NASA Technical Reports Server (NTRS)

    Park, Jae H. (Editor); Ko, Malcolm K. W. (Editor); Jackman, Charles H. (Editor); Plumb, R. Alan (Editor); Kaye, Jack A. (Editor); Sage, Karen H. (Editor)

    1999-01-01

    Models and Measurement Intercomparison II (MM II) summarizes the intercomparison of results from model simulations and observations of stratospheric species. Representatives from twenty-three modeling groups using twenty-nine models participated in these MM II exercises between 1996 and 1999. Twelve of the models were two- dimensional zonal-mean models while seventeen were three-dimensional models. This was an international effort as seven were from outside the United States. Six transport experiments and five chemistry experiments were designed for various models. Models participating in the transport experiments performed simulations of chemically inert tracers providing diagnostics for transport. The chemistry experiments involved simulating the distributions of chemically active trace cases including ozone. The model run conditions for dynamics and chemistry were prescribed in order to minimize the factors that caused differences in the models. The report includes a critical review of the results by the participants and a discussion of the causes of differences between modeled and measured results as well as between results from different models, A sizable effort went into preparation of the database of the observations. This included a new climatology for ozone. The report should help in evaluating the results from various predictive models for assessing humankind perturbations of the stratosphere.

  2. Criticality accident dosimetry systems: an international intercomparison at the SILENE reactor in 2002.

    PubMed

    Médioni, R; Asselineau, B; Verrey, B; Trompier, F; Itié, C; Texier, C; Muller, H; Pelcot, G; Clairand, I; Jacquet, X; Pochat, J L

    2004-01-01

    In criticality accident dosimetry and more generally for high dose measurements, special techniques are used to measure separately the gamma ray and neutron components of the dose. To improve these techniques and to check their dosimetry systems (physical and/or biological), a total of 60 laboratories from 29 countries (America, Europe, Asia) participated in an international intercomparaison, which took place in France from 9 to 21 June 2002, at the SILENE reactor in Valduc and at a pure gamma source in Fontenay-aux-Roses. This intercomparison was jointly organised by the IRSN and the CEA with the help of the NEA/OCDE and was partly supported by the European Communities. This paper describes the aim of this intercomparison, the techniques used by the participants and the two radiation sources and their characteristics. The experimental arrangements of the dosemeters for the irradiations in free air or on phantoms are given. Then the dosimetric quantities measured and reported by the participants are summarised, analysed and compared with the reference values. The present paper concerns only the physical dosimetry and essentially experiments performed on the SILENE facility. The results obtained with the biological dosimetry are published in two other papers of this issue.

  3. Metafitting: Weight optimization for least-squares fitting of PTTI data

    NASA Technical Reports Server (NTRS)

    Douglas, Rob J.; Boulanger, J.-S.

    1995-01-01

    For precise time intercomparisons between a master frequency standard and a slave time scale, we have found it useful to quantitatively compare different fitting strategies by examining the standard uncertainty in time or average frequency. It is particularly useful when designing procedures which use intermittent intercomparisons, with some parameterized fit used to interpolate or extrapolate from the calibrating intercomparisons. We use the term 'metafitting' for the choices that are made before a fitting procedure is operationally adopted. We present methods for calculating the standard uncertainty for general, weighted least-squares fits and a method for optimizing these weights for a general noise model suitable for many PTTI applications. We present the results of the metafitting of procedures for the use of a regular schedule of (hypothetical) high-accuracy frequency calibration of a maser time scale. We have identified a cumulative series of improvements that give a significant reduction of the expected standard uncertainty, compared to the simplest procedure of resetting the maser synthesizer after each calibration. The metafitting improvements presented include the optimum choice of weights for the calibration runs, optimized over a period of a week or 10 days.

  4. The DeepMIP Contribution to PMIP4: Experimental Design for Model Simulations of the EECO, PETM, and pre-PETM (version 1.0)

    NASA Technical Reports Server (NTRS)

    Lunt, Daniel J.; Huber, Matthew; Anagnostou, Eleni; Baatsen, Michiel L. J.; Caballero, Rodrigo; DeConto, Rob; Dijkstra, Henk A.; Donnadieu, Yannick; Evans, David; Feng, Ran; hide

    2017-01-01

    Past warm periods provide an opportunity to evaluate climate models under extreme forcing scenarios, in particular high ( greater than 800 ppmv) atmospheric CO2 concentrations. Although a post hoc intercomparison of Eocene (approximately 50 Ma) climate model simulations and geological data has been carried out previously, models of past high-CO2 periods have never been evaluated in a consistent framework. Here, we present an experimental design for climate model simulations of three warm periods within the early Eocene and the latest Paleocene (the EECO, PETM, and pre-PETM). Together with the CMIP6 pre-industrial control and abrupt 4(times) CO2 simulations, and additional sensitivity studies, these form the first phase of DeepMIP - the Deep-time Model Intercomparison Project, itself a group within the wider Paleoclimate Modeling Intercomparison Project (PMIP). The experimental design specifies and provides guidance on boundary conditions associated with palaeogeography, greenhouse gases, astronomical configuration, solar constant, land surface processes, and aerosols. Initial conditions, simulation length, and output variables are also specified. Finally, we explain how the geological data sets, which will be used to evaluate the simulations, will be developed.

  5. The T-REX valley wind intercomparison project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidli, J; Billings, B J; Burton, R

    2008-08-07

    An accurate simulation of the evolution of the atmospheric boundary layer is very important, as the evolution of the boundary layer sets the stage for many weather phenomena, such as deep convection. Over mountain areas the evolution of the boundary layer is particularly complex, due to the nonlinear interaction between boundary layer turbulence and thermally-induced mesoscale wind systems, such as the slope and valley winds. As the horizontal resolution of operational forecasts progresses to finer and finer resolution, more and more of the thermally-induced mesoscale wind systems can be explicitly resolved, and it is very timely to document the currentmore » state-of-the-art of mesoscale models at simulating the coupled evolution of the mountain boundary layer and the valley wind system. In this paper we present an intercomparison of valley wind simulations for an idealized valley-plain configuration using eight state-of-the-art mesoscale models with a grid spacing of 1 km. Different sets of three-dimensional simulations are used to explore the effects of varying model dynamical cores and physical parameterizations. This intercomparison project was conducted as part of the Terrain-induced Rotor Experiment (T-REX; Grubisic et al., 2008).« less

  6. Intercomparison of different operational oceanographic forecast products in the CMEMS IBI area

    NASA Astrophysics Data System (ADS)

    Lorente, Pablo; Sotillo, Marcos G.; Dabrowski, Tomasz; Amo-Baladrón, Arancha; Aznar, Roland; De Pascual, Alvaro; Levier, Bruno; Bowyer, Peter; Cossarini, Gianpiero; Salon, Stefano; Tonani, Marina; Alvarez-Fanjul, Enrique

    2017-04-01

    The development of skill assessment software packages and dedicated web applications is a relatively novel theme in operational oceanography. Within the CMEMS IBI-MFC, the quality of IBI (Iberia-Biscay-Ireland) forecast products is assessed by means of NARVAL (North Atlantic Regional VALidation) web-based tool. The validation of IBI against independent in situ and remote-sensing measurements is routinely conducted to evaluate model's veracity and prognostic capabilities. Noticeable efforts are in progress to define meaningful skill scores and statistical metrics to quantitatively assess the quality and reliability of the IBI model solution. Likewise, the IBI-MFC compares the IBI forecast products with other model solutions by setting up specific intercomparison exercises on overlapping areas at diverse timescales. In this context, NARVAL web tool already includes a specific module to evaluate strengths and weaknesses of IBI versus other CMEMS operational ocean forecasting systems (OOFSs). In particular, the IBI physical ocean solution is compared against the CMEMS MED and NWS OOFSs. These CMEMS regional services delivered for the Mediterranean and the North West Shelves include data assimilation schemes in their respective operational chains and generate analogous ocean forecast products to the IBI ones. A number of physical parameters (i.e. sea surface temperature, salinity and current velocities) are evaluated through NARVAL on a daily basis in the overlapping areas existing between these three regional systems. NARVAL is currently being updated in order to extend this intercomparison of ocean model parameters to the biogeochemical solutions provided by the aforementioned OOFSs. More specifically, the simulated chlorophyll concentration is evaluated over several subregions of particular concern by using as benchmark the CMEMS satellite-derived observational products. In addition to this IBI comparison against other regional CMEMS products on overlapping areas, a specific intercomparison between the CMEMS GLOBAL solution and the IBI (regional application dynamically embedded in the former) is conducted in order to check its consistency and ability to outperform the parent model solution. Particular emphasis is placed on the comparison of time-series at specified locations (class-2 metrics). The standardized validation methodology presented here is particularly useful and could encompass the intercomparison of the regional application (IBI) and other nested higher resolution models at coastal/shelf scales to quantify the added value of downscaling in local downstream approaches.

  7. A protocol for the intercomparison of marine fishery and ecosystem models: Fish-MIP v1.0

    NASA Astrophysics Data System (ADS)

    Tittensor, Derek P.; Eddy, Tyler D.; Lotze, Heike K.; Galbraith, Eric D.; Cheung, William; Barange, Manuel; Blanchard, Julia L.; Bopp, Laurent; Bryndum-Buchholz, Andrea; Büchner, Matthias; Bulman, Catherine; Carozza, David A.; Christensen, Villy; Coll, Marta; Dunne, John P.; Fernandes, Jose A.; Fulton, Elizabeth A.; Hobday, Alistair J.; Huber, Veronika; Jennings, Simon; Jones, Miranda; Lehodey, Patrick; Link, Jason S.; Mackinson, Steve; Maury, Olivier; Niiranen, Susa; Oliveros-Ramos, Ricardo; Roy, Tilla; Schewe, Jacob; Shin, Yunne-Jai; Silva, Tiago; Stock, Charles A.; Steenbeek, Jeroen; Underwood, Philip J.; Volkholz, Jan; Watson, James R.; Walker, Nicola D.

    2018-04-01

    Model intercomparison studies in the climate and Earth sciences communities have been crucial to building credibility and coherence for future projections. They have quantified variability among models, spurred model development, contrasted within- and among-model uncertainty, assessed model fits to historical data, and provided ensemble projections of future change under specified scenarios. Given the speed and magnitude of anthropogenic change in the marine environment and the consequent effects on food security, biodiversity, marine industries, and society, the time is ripe for similar comparisons among models of fisheries and marine ecosystems. Here, we describe the Fisheries and Marine Ecosystem Model Intercomparison Project protocol version 1.0 (Fish-MIP v1.0), part of the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP), which is a cross-sectoral network of climate impact modellers. Given the complexity of the marine ecosystem, this class of models has substantial heterogeneity of purpose, scope, theoretical underpinning, processes considered, parameterizations, resolution (grain size), and spatial extent. This heterogeneity reflects the lack of a unified understanding of the marine ecosystem and implies that the assemblage of all models is more likely to include a greater number of relevant processes than any single model. The current Fish-MIP protocol is designed to allow these heterogeneous models to be forced with common Earth System Model (ESM) Coupled Model Intercomparison Project Phase 5 (CMIP5) outputs under prescribed scenarios for historic (from the 1950s) and future (to 2100) time periods; it will be adapted to CMIP phase 6 (CMIP6) in future iterations. It also describes a standardized set of outputs for each participating Fish-MIP model to produce. This enables the broad characterization of differences between and uncertainties within models and projections when assessing climate and fisheries impacts on marine ecosystems and the services they provide. The systematic generation, collation, and comparison of results from Fish-MIP will inform an understanding of the range of plausible changes in marine ecosystems and improve our capacity to define and convey the strengths and weaknesses of model-based advice on future states of marine ecosystems and fisheries. Ultimately, Fish-MIP represents a step towards bringing together the marine ecosystem modelling community to produce consistent ensemble medium- and long-term projections of marine ecosystems.

  8. Calcium - urine

    MedlinePlus

    Urinary Ca+2; Kidney stones - calcium in urine; Renal calculi - calcium in your urine; Parathyroid - calcium in urine ... A 24-hour urine sample is most often needed: On day 1, urinate into the toilet when you wake up in the morning. ...

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weaver, Virginia M., E-mail: vweaver@jhsph.edu; Johns Hopkins University School of Medicine, Baltimore, MD; Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, bloodmore » lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m{sup 2}; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed.« less

  10. Salt as a mitigation option for decreasing nitrogen leaching losses from grazed pastures.

    PubMed

    Ledgard, Stewart F; Welten, Brendon; Betteridge, Keith

    2015-12-01

    The main source of nitrogen (N) leaching from grazed pastures is animal urine with a high N deposition rate (i.e. per urine patch), particularly between late summer and early winter. Salt is a potential mitigation option as a diuretic to induce greater drinking-water intake, increase urination frequency, decrease urine N concentration and urine N deposition rate, and thereby potentially decrease N leaching. This hypothesis was tested in three phases: a cattle metabolism stall study to examine effects of salt supplementation rate on water consumption, urination frequency and urine N concentration; a grazing trial to assess effects of salt (150 g per heifer per day) on urination frequency; and a lysimeter study on effects of urine N rate on N leaching. Salt supplementation increased cattle water intake. Urination frequency increased by up to 69%, with a similar decrease in urine N deposition rate and no change in individual urination volume. Under field grazing, sensors showed increased urination frequency by 17%. Lysimeter studies showed a proportionally greater decrease in N leaching with decreased urine N rate. Modelling revealed that this could decrease per-hectare N leaching by 10-22%. Salt supplementation increases cattle water intake and urination frequency, resulting in a lower urine N deposition rate and proportionally greater decrease in urine N leaching. Strategic salt supplementation in autumn/early winter with feed is a practical mitigation option to decrease N leaching in grazed pastures. © 2015 Society of Chemical Industry.

  11. Acid mucopolysaccharides

    MedlinePlus

    AMP; Dermatan sulfate - urine; Urine heparan sulfate; Urine dermatan sulfate; Heparan sulfate - urine ... the smaller special container and then transfer that urine into the other larger container. On day 1, ...

  12. Porphyrins - urine test

    MedlinePlus

    Urine uroporphyrin; Urine coproporphyrin; Porphyria - uroporphyrin ... After you provide a urine sample, it is tested in the lab. This is called a random urine sample. If needed, your health care provider ...

  13. Comparison of routine urinalysis and urine Gram stain for detection of bacteriuria in dogs.

    PubMed

    Way, Leilani Ireland; Sullivan, Lauren A; Johnson, Valerie; Morley, Paul S

    2013-01-01

    To determine the utility of performing urine Gram stain for detection of bacteriuria compared to routine urine sediment examination and bacterial aerobic urine culture. Prospective, observational study. University teaching hospital. Urine samples acquired via cystocentesis through convenience sampling from 103 dogs presenting to a tertiary referral institution. All samples underwent routine urinalysis, including sediment examination, as well as urine Gram stain and quantitative bacterial aerobic urine culture. The urine Gram stain demonstrated improved sensitivity (96% versus 76%), specificity (100% versus 77%), positive predictive value (100% versus 83%), and negative predictive value (93% versus 69%) when identifying bacteriuria, compared to routine urine sediment examination. The urine Gram stain is highly sensitive and specific when detecting the presence of bacteria in canine urine samples. Gram staining should be considered when bacteriuria is highly suspected and requires rapid identification while bacterial culture is pending. © Veterinary Emergency and Critical Care Society 2013.

  14. Relationship between conventional culture and flow cytometry for the diagnosis of urinary tract infection.

    PubMed

    García-Coca, Marta; Gadea, Ignacio; Esteban, Jaime

    2017-06-01

    Urine culture is the gold standard for the diagnosis of urinary tract infections (UTI). The use of flow cytometry analyzers (FCA) prior to culture allows for the quantification and recognition of cell components in urine to be automated and makes it possible to relate these data to the urine pathogens subsequently identified in cultures. Urine samples were assessed with the Sysmex UF-1000i analyzer. Those that met the criteria for culture (> 25 leukocytes/μL or > 385 bacteria/μL) were subjected to quantitative urine culture on chromogenic agar. Counts of red blood cells (RBC), white blood cells (WBC), epithelial cells (EC), and the kind of microorganisms identified in cultures were evaluated. A total of 17,483 samples were processed by FCA. Of these, 9057 met the criteria for culture. Urine cultures were reduced by 48.2%. The most common urine pathogen was Escherichia coli (60.3%). Negative urine cultures were significantly (p < 0.001) associated with a lower WBC count than urine with E. coli, Klebsiella spp. and Proteus spp., but urine with Enterococcus spp. had a lower WBC than negative urine. Contaminated urine had a significantly (p < 0.001) lower WBC than urine with E. coli, Klebsiella spp. and Proteus spp., but no differences were found for Enterococcus spp. (p = 0.729). Negative urine cultures had significantly (p < 0.05) higher EC than all positive urine samples. Contaminated urine was associated (p < 0.001) with higher EC than cultures with E. coli and Klebsiella spp., in comparison with cultures with Enterococcus spp. (p = 0.091) and Proteus spp. (p = 0.251). The use of the Sysmex UF-1000i flow cytometer for screening urine samples allows for a reduction in the number of urine cultures. WBC values correlate well with the main urine pathogens related to UTI. The results observed for Enterococcus spp. suggest a low impact of these pathogens as a cause of UTI.

  15. Protein urine test

    MedlinePlus

    Urine protein; Albumin - urine; Urine albumin; Proteinuria; Albuminuria ... After you provide a urine sample, it is tested. The health care provider uses a dipstick made with a color-sensitive pad. The color change ...

  16. Automated color classification of urine dipstick image in urine examination

    NASA Astrophysics Data System (ADS)

    Rahmat, R. F.; Royananda; Muchtar, M. A.; Taqiuddin, R.; Adnan, S.; Anugrahwaty, R.; Budiarto, R.

    2018-03-01

    Urine examination using urine dipstick has long been used to determine the health status of a person. The economical and convenient use of urine dipstick is one of the reasons urine dipstick is still used to check people health status. The real-life implementation of urine dipstick is done manually, in general, that is by comparing it with the reference color visually. This resulted perception differences in the color reading of the examination results. In this research, authors used a scanner to obtain the urine dipstick color image. The use of scanner can be one of the solutions in reading the result of urine dipstick because the light produced is consistent. A method is required to overcome the problems of urine dipstick color matching and the test reference color that have been conducted manually. The method proposed by authors is Euclidean Distance, Otsu along with RGB color feature extraction method to match the colors on the urine dipstick with the standard reference color of urine examination. The result shows that the proposed approach was able to classify the colors on a urine dipstick with an accuracy of 95.45%. The accuracy of color classification on urine dipstick against the standard reference color is influenced by the level of scanner resolution used, the higher the scanner resolution level, the higher the accuracy.

  17. Urine creatinine in treatment-naïve HIV subjects in eastern Nigeria

    PubMed Central

    Anyabolu, Ernest Ndukaife

    2016-01-01

    Introduction Human immunodeficiency virus (HIV) infection is a global healthcare problem. Some diseases and physiological states may be altered in HIV-infected individuals. Our objective was to evaluate urine creatinine and factors that influence urine creatinine in treatment-naïve HIV subjects in Nigeria. Methods This was a cross-sectional study involving treatment-naïve HIV subjects in a tertiary hospital in Nigeria. Creatinine in spot and 24-hour urine samples and other relevant investigations were performed. Low urine creatinine or dilute urine was defined as 24-hour urine creatinine (24HUCr) <300mg, normal urine creatinine as 24HUCr 300-3000mg and high urine creatinine or concentrated urine as 24HUCr>3000mg.Theassociation of low urine creatinine and high urine creatinine with potential risk factors was determined. Results The mean spot urine creatinine (SUCr) of the treatment-naïve HIV subjects was 137.21± 98.47(mg/dl), minimum value 13.3mg/dl, maximum value 533.3mg/dl and range of values 520.0mg/dl. The mean 24HUCr was 1507±781mg, minimum value 206mg, maximum value 4849mg and range of values 4643mg. Twenty four-hour urine creatinine<300mg was observed in 2(0.5%) subjects, normal 24HUCr 300-3000mgin 349(93.1%) subjects and 24HUCr>3000mg in 24(6.4%) subjects. There was significant association between 24HUCr and serum low density lipoprotein cholesterol (LDL),serum high density lipoprotein cholesterol (HDL). There was high correlation between 24HUCr>3000mg and 24-hour urine osmolality (24HUOsm) (r=0.95), body mass index (BMI) (r=0.74), CD4 cells count (r=-0.71), serum HDL (r=-0.73). Conclusion The prevalence of dilute urine and concentrated urine was low. Twenty-four hour urine osmolality. BMI, CD4 cells count and HDL were strong correlates of high urine creatinine. Lipid abnormalities were common in treatment-naïve HIV subjects with high urine creatinine. There is need for clinicians to routinely conduct urine creatinine and further search for abnormalities of serum lipids, weight changes, depressed immunity and anemia in HIV subjects with dilute or concentrated urine in the early stages of the infection. PMID:28292101

  18. Urine creatinine in treatment-naïve HIV subjects in eastern Nigeria.

    PubMed

    Anyabolu, Ernest Ndukaife

    2016-01-01

    Human immunodeficiency virus (HIV) infection is a global healthcare problem. Some diseases and physiological states may be altered in HIV-infected individuals. Our objective was to evaluate urine creatinine and factors that influence urine creatinine in treatment-naïve HIV subjects in Nigeria. This was a cross-sectional study involving treatment-naïve HIV subjects in a tertiary hospital in Nigeria. Creatinine in spot and 24-hour urine samples and other relevant investigations were performed. Low urine creatinine or dilute urine was defined as 24-hour urine creatinine (24HUCr) <300mg, normal urine creatinine as 24HUCr 300-3000mg and high urine creatinine or concentrated urine as 24HUCr>3000mg.Theassociation of low urine creatinine and high urine creatinine with potential risk factors was determined. The mean spot urine creatinine (SUCr) of the treatment-naïve HIV subjects was 137.21± 98.47(mg/dl), minimum value 13.3mg/dl, maximum value 533.3mg/dl and range of values 520.0mg/dl. The mean 24HUCr was 1507±781mg, minimum value 206mg, maximum value 4849mg and range of values 4643mg. Twenty four-hour urine creatinine<300mg was observed in 2(0.5%) subjects, normal 24HUCr 300-3000mgin 349(93.1%) subjects and 24HUCr>3000mg in 24(6.4%) subjects. There was significant association between 24HUCr and serum low density lipoprotein cholesterol (LDL),serum high density lipoprotein cholesterol (HDL). There was high correlation between 24HUCr>3000mg and 24-hour urine osmolality (24HUOsm) (r=0.95), body mass index (BMI) (r=0.74), CD4 cells count (r=-0.71), serum HDL (r=-0.73). The prevalence of dilute urine and concentrated urine was low. Twenty-four hour urine osmolality. BMI, CD4 cells count and HDL were strong correlates of high urine creatinine. Lipid abnormalities were common in treatment-naïve HIV subjects with high urine creatinine. There is need for clinicians to routinely conduct urine creatinine and further search for abnormalities of serum lipids, weight changes, depressed immunity and anemia in HIV subjects with dilute or concentrated urine in the early stages of the infection.

  19. The development and validation of different decision-making tools to predict urine culture growth out of urine flow cytometry parameter.

    PubMed

    Müller, Martin; Seidenberg, Ruth; Schuh, Sabine K; Exadaktylos, Aristomenis K; Schechter, Clyde B; Leichtle, Alexander B; Hautz, Wolf E

    2018-01-01

    Patients presenting with suspected urinary tract infection are common in every day emergency practice. Urine flow cytometry has replaced microscopic urine evaluation in many emergency departments, but interpretation of the results remains challenging. The aim of this study was to develop and validate tools that predict urine culture growth out of urine flow cytometry parameter. This retrospective study included all adult patients that presented in a large emergency department between January and July 2017 with a suspected urinary tract infection and had a urine flow cytometry as well as a urine culture obtained. The objective was to identify urine flow cytometry parameters that reliably predict urine culture growth and mixed flora growth. The data set was split into a training (70%) and a validation set (30%) and different decision-making approaches were developed and validated. Relevant urine culture growth (respectively mixed flora growth) was found in 40.2% (7.2% respectively) of the 613 patients included. The number of leukocytes and bacteria in flow cytometry were highly associated with urine culture growth, but mixed flora growth could not be sufficiently predicted from the urine flow cytometry parameters. A decision tree, predictive value figures, a nomogram, and a cut-off table to predict urine culture growth from bacteria and leukocyte count were developed, validated and compared. Urine flow cytometry parameters are insufficient to predict mixed flora growth. However, the prediction of urine culture growth based on bacteria and leukocyte count is highly accurate and the developed tools should be used as part of the decision-making process of ordering a urine culture or starting an antibiotic therapy if a urogenital infection is suspected.

  20. The development and validation of different decision-making tools to predict urine culture growth out of urine flow cytometry parameter

    PubMed Central

    Seidenberg, Ruth; Schuh, Sabine K.; Exadaktylos, Aristomenis K.; Schechter, Clyde B.; Leichtle, Alexander B.; Hautz, Wolf E.

    2018-01-01

    Objective Patients presenting with suspected urinary tract infection are common in every day emergency practice. Urine flow cytometry has replaced microscopic urine evaluation in many emergency departments, but interpretation of the results remains challenging. The aim of this study was to develop and validate tools that predict urine culture growth out of urine flow cytometry parameter. Methods This retrospective study included all adult patients that presented in a large emergency department between January and July 2017 with a suspected urinary tract infection and had a urine flow cytometry as well as a urine culture obtained. The objective was to identify urine flow cytometry parameters that reliably predict urine culture growth and mixed flora growth. The data set was split into a training (70%) and a validation set (30%) and different decision-making approaches were developed and validated. Results Relevant urine culture growth (respectively mixed flora growth) was found in 40.2% (7.2% respectively) of the 613 patients included. The number of leukocytes and bacteria in flow cytometry were highly associated with urine culture growth, but mixed flora growth could not be sufficiently predicted from the urine flow cytometry parameters. A decision tree, predictive value figures, a nomogram, and a cut-off table to predict urine culture growth from bacteria and leukocyte count were developed, validated and compared. Conclusions Urine flow cytometry parameters are insufficient to predict mixed flora growth. However, the prediction of urine culture growth based on bacteria and leukocyte count is highly accurate and the developed tools should be used as part of the decision-making process of ordering a urine culture or starting an antibiotic therapy if a urogenital infection is suspected. PMID:29474463

  1. Consideration of the degree of increase in urine metadrenalines provides superior specificity in the diagnosis of phaeochromocytoma than additional urine catecholamine measurement.

    PubMed

    Scargill, J J; Reed, P; Kane, J

    2013-01-01

    Measurement of fractionated plasma or urine metadrenalines is the recommended screening test in the diagnosis of phaeochromocytoma, with clinical cut-offs geared towards diagnostic sensitivity. Current practice at Salford Royal Hospital is to add urine catecholamines onto samples with raised urine metadrenalines, with the aim of adding specificity to a diagnosis of phaeochromocytoma. This practice was reviewed by identifying a series of patients with raised urine metadrenalines who had catecholamines reflectively added. A total of 358 samples were identified from 242 patients, of which 228 had urine catecholamines measured. A diagnosis of 'phaeochromocytoma' (n = 41) or 'no phaeochromocytoma' (n = 90) was obtained in 131 of 228 patients, giving raised urine metadrenalines a positive predictive value for phaeochromocytoma of 31%. The finding of increased urine catecholamines in samples with raised urine metadrenalines increased specificity for phaeochromocytoma to 70%. However, 95% diagnostic specificity for phaeochromocytoma could be achieved by the introduction of a second cut-off for urine metadrenalines geared towards maximizing specificity. Consideration of the degree of increase in urine metadrenalines is a superior method of determining the likelihood of phaeochromocytoma than measurement of urine catecholamines.

  2. The SPARC Intercomparison of Middle Atmosphere Climatologies

    NASA Technical Reports Server (NTRS)

    Randel, William; Fleming, Eric; Geller, Marvin; Gelman, Mel; Hamilton, Kevin; Karoly, David; Ortland, Dave; Pawson, Steve; Swinbank, Richard; Udelhofen, Petra

    2003-01-01

    Our current confidence in 'observed' climatological winds and temperatures in the middle atmosphere (over altitudes approx. 10-80 km) is assessed by detailed intercomparisons of contemporary and historic data sets. These data sets include global meteorological analyses and assimilations, climatologies derived from research satellite measurements, and historical reference atmosphere circulation statistics. We also include comparisons with historical rocketsonde wind and temperature data, and with more recent lidar temperature measurements. The comparisons focus on a few basic circulation statistics, such as temperature, zonal wind, and eddy flux statistics. Special attention is focused on tropical winds and temperatures, where large differences exist among separate analyses. Assimilated data sets provide the most realistic tropical variability, but substantial differences exist among current schemes.

  3. LIDAR mapping of ozone-episode dynamics in Paris and intercomparison with spot analyzers Supplementary material available at http://link.springer.de/journals/apb

    NASA Astrophysics Data System (ADS)

    Thomasson, A.; Geffroy, S.; Frejafon, E.; Weidauer, D.; Fabian, R.; Godet, Y.; Nominé, M.; Ménard, T.; Rairoux, P.; Moeller, D.; Wolf, J. P.

    Continuous mapping of an ozone episode in Paris in June 1999 has been performed using a differential absorption lidar system. The 2D ozone concentration vertical maps recorded over 33 h at the Champ de Mars are compiled in a video clip that gives access to local photochemical dynamics with unprecedented precision. The lidar data are compared over the whole period with point monitors located at 0-, 50-, and 300-m altitudes on the Eiffel Tower. Very good agreement is found when spatial resolution, acquisition time, and required concentration accuracy are optimized. Sensitivity to these parameters for successful intercomparison in urban areas is discussed.

  4. An intercomparison of longwave measurements by ERBE radiometers on the NOAA-9 and ERBS satellites

    NASA Technical Reports Server (NTRS)

    House, Frederick B.

    1989-01-01

    Two instrument modules of each satellite on which the Earth Radiation Budget Experiment (ERBE) is orbiting observe components of the earth radiation budget with three different scales of earth view. An intercomparison of longwave measurements by these instruments provides relative information concerning radiometric performance at satellite altitude, techniques of estimating upwelling exitances, and an end-to-end evaluation of the data processing system. Results indicate that the ERBE radiometers are mildly sensitive to varying thermal loads from the spacecraft and/or the earth-space environment. Radiometric variations at the satellite and methods of data interpretation contribute about equally to the uncertainty of radiant exitances from the earth.

  5. Intercomparisons of radiosondes and an airborne refractometer for measuring radio ducts

    NASA Astrophysics Data System (ADS)

    Morrissey, J. F.; Izumi, Y.; Cote, O. R.

    1986-07-01

    The capabilities of two types of radiosondes and an aircraft refractometer to measure radio ducting conditions were compared in a series of flights in September 1985 at Chatham, Mass., on Cape Cod. The tests were part of a program studying radio propagation on Air Force communication links. The intercomparisons were made between data from a refractometer mounted on a small single engine aircraft (Cessna 172) and data from an operational National Weather Service synoptic sounding system. The synoptic sonde and the portable sonde were often on the same balloon train. The comparisons show that the aircraft refractometer data indicate the highest number of ducts and the synoptic data the least number of ducts.

  6. An evaluation of 20th century climate for the Southeastern United States as simulated by Coupled Model Intercomparison Project Phase 5 (CMIP5) global climate models

    USGS Publications Warehouse

    David E. Rupp,

    2016-05-05

    The 20th century climate for the Southeastern United States and surrounding areas as simulated by global climate models used in the Coupled Model Intercomparison Project Phase 5 (CMIP5) was evaluated. A suite of statistics that characterize various aspects of the regional climate was calculated from both model simulations and observation-based datasets. CMIP5 global climate models were ranked by their ability to reproduce the observed climate. Differences in the performance of the models between regions of the United States (the Southeastern and Northwestern United States) warrant a regional-scale assessment of CMIP5 models.

  7. Chemical differences between voided and bladder urine in the aye-aye (Daubentonia madagascariensis): implications for olfactory communication studies.

    PubMed

    Delbarco-Trillo, Javier; Harelimana, Innocent H; Goodwin, Thomas E; Drea, Christine M

    2013-07-01

    Urine serves a communicative function in many mammalian species. In some species, the signaling function of urine can be enhanced by the addition of chemical compounds from glands along the distal portion of the urogenital tract. Although urine marking is the main mode of chemical communication in many primate species, there has been no study of the contribution of urogenital secretions to the chemical complexity of primate urine. Here, we compared the chemical composition of bladder urine versus voided urine in the aye-aye, Daubentonia madagascariensis, a strepsirrhine primate that relies on urine in intraspecific communication. Both types of urine, collected from each of 11 aye-ayes representing both sexes of varying adult ages, underwent headspace analysis via gas chromatography and mass spectrometry. Although the average number of compounds was similar in bladder and voided urine, 17% of the compounds detected occurred exclusively in voided urine (but only in a subset of individuals). An overall measure of chemical complexity (using a nonmetric multidimensional scaling analysis) showed that both types of urine were chemically different at the individual level. There was no apparent sex or age differences in the chemical components found in aye-aye urine. Nonetheless, the individual dissimilarities between bladder urine and voided urine indicate chemical contributions from structures along the urogenital tract and offer further support for the relevance of urinary communication in the aye-aye. © 2012 Wiley Periodicals, Inc.

  8. Toilet compost and human urine used in agriculture: fertilizer value assessment and effect on cultivated soil properties.

    PubMed

    Sangare, D; Sou Dakoure, M; Hijikata, N; Lahmar, R; Yacouba, H; Coulibaly, L; Funamizu, N

    2015-01-01

    Toilet compost (TC) and human urine are among natural fertilizers, which raise interest due to their double advantages to combine sanitation and nutrient recovery. However, combination of urine and TC is not so spread probably because the best ratio (urine/TC) is still an issue and urine effect on soil chemical properties remains poorly documented. This study aims to determine the best ratio of urine and TC in okra cultivation, by targeting higher fertilization effect combined with lower impact on soil chemical properties. Based on Nitrogen requirement of okra, seven treatments were compared: (T0) no fertilizer, (T1) chemical fertilizer (NPK: 14-23-14), (T2) 100% urine, (T3) 100% TC, (T4) ratio of 75% urine+25% TC, (T5) 50% urine+50% TC and (T6) 25% urine+75% TC. Results indicated that T4 (75% urine+25% TC) gave the highest plant height and yield. In contrast, T2 (100% urine) gave the lowest results among all treatments, indicating toxicity effects on plant growth and associated final yield. Such toxicity is confirmed by soil chemical properties at T2 with soil acidification and significant increase in soil salinity. In contrast, application of urine together with TC mitigates soil acidification and salinity, highlighting the efficiency of urine and TC combination on soil chemical properties. However, further investigation is necessary to refine better urine/TC ratio for okra production.

  9. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    PubMed

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.

  10. Life cycle comparison of centralized wastewater treatment and urine source separation with struvite precipitation: Focus on urine nutrient management.

    PubMed

    Ishii, Stephanie K L; Boyer, Treavor H

    2015-08-01

    Alternative approaches to wastewater management including urine source separation have the potential to simultaneously improve multiple aspects of wastewater treatment, including reduced use of potable water for waste conveyance and improved contaminant removal, especially nutrients. In order to pursue such radical changes, system-level evaluations of urine source separation in community contexts are required. The focus of this life cycle assessment (LCA) is managing nutrients from urine produced in a residential setting with urine source separation and struvite precipitation, as compared with a centralized wastewater treatment approach. The life cycle impacts evaluated in this study pertain to construction of the urine source separation system and operation of drinking water treatment, decentralized urine treatment, and centralized wastewater treatment. System boundaries include fertilizer offsets resulting from the production of urine based struvite fertilizer. As calculated by the Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI), urine source separation with MgO addition for subsequent struvite precipitation with high P recovery (Scenario B) has the smallest environmental cost relative to existing centralized wastewater treatment (Scenario A) and urine source separation with MgO and Na3PO4 addition for subsequent struvite precipitation with concurrent high P and N recovery (Scenario C). Preliminary economic evaluations show that the three urine management scenarios are relatively equal on a monetary basis (<13% difference). The impacts of each urine management scenario are most sensitive to the assumed urine composition, the selected urine storage time, and the assumed electricity required to treat influent urine and toilet water used to convey urine at the centralized wastewater treatment plant. The importance of full nutrient recovery from urine in combination with the substantial chemical inputs required for N recovery via struvite precipitation indicate the need for alternative methods of N recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Lactic acid fermentation of human urine to improve its fertilizing value and reduce odour emissions.

    PubMed

    Andreev, N; Ronteltap, M; Boincean, B; Wernli, M; Zubcov, E; Bagrin, N; Borodin, N; Lens, P N L

    2017-08-01

    During storage of urine, urea is biologically decomposed to ammonia, which can be lost through volatilization and in turn causes significant unpleasant smell. In response, lactic acid fermentation of urine is a cost-effective technique to decrease nitrogen volatilization and reduce odour emissions. Fresh urine (pH = 5.2-5.3 and NH 4 + -N = 1.2-1.3 g L -1 ) was lacto-fermented for 36 days in closed glass jars with a lactic acid bacterial inoculum from sauerkraut juice and compared to untreated, stored urine. In the lacto-fermented urine, the pH was reduced to 3.8-4.7 and the ammonium content by 22-30%, while the pH of the untreated urine rose to 6.1 and its ammonium content increased by 32% due to urea hydrolysis. The concentration of lactic acid bacteria in lacto-fermented urine was 7.3 CFU ml -1 , suggesting that urine is a suitable growth medium for lactic acid bacteria. The odour of the stored urine was subjectively perceived by four people to be twice as strong as that of lacto-fermented samples. Lacto-fermented urine induced increased radish germination compared to stored urine (74-86% versus 2-31%). Adding a lactic acid bacterial inoculum to one week old urine in the storage tanks in a urine-diverting dry toilet reduced the pH from 8.9 to 7.7 after one month, while the ammonium content increased by 35%, probably due to the high initial pH of the urine. Given that the hydrolyzed stale urine has a high buffering capacity, the lactic acid bacterial inoculum should be added to the urine storage tank of a UDDT before urine starts to accumulate there to increase the efficiency of the lactic acid fermentation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Comparison of sodium, potassium, calcium, magnesium, zinc, copper and iron concentrations of elements in 24-h urine and spot urine in hypertensive patients with healthy renal function.

    PubMed

    Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi

    2017-12-01

    Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.

  13. Urine melanin test

    MedlinePlus

    Thormahlen's test; Melanin - urine ... A clean-catch urine sample is needed. ... this substance that it shows up in the urine. ... Normally, melanin is not present in urine. Normal value ranges may ... measurements or test different samples. Talk to your health ...

  14. Prevalence of isolated non-albumin proteinuria in the US population tested for both, urine total protein and urine albumin: An unexpected discovery.

    PubMed

    Katayev, Alexander; Zebelman, Arthur M; Sharp, Thomas M; Samantha Flynn; Bernstein, Richard K

    2017-04-01

    Isolated non-albumin proteinuria (NAP) is a condition when urine total protein concentrations are elevated without elevation of urine albumin. The prevalence of NAP in the US population tested for both, urine total protein and albumin was assessed in this study. The database of a US nationwide laboratory network was queried for test results when random urine albumin was ordered together with urine total protein and also when timed 24-hour urine albumin was ordered together with urine total protein. The total prevalence of NAP in the US population tested for both, urine total protein and albumin was calculated for patient groups having normal and low-normal urine albumin (random and timed) with elevated and severely increased urine total protein (random and timed). Also, the prevalence of NAP was calculated for patients with normal urine albumin to assess the probability of missing proteinuria if only urine albumin is measured. The prevalence of NAP in the random samples group was 10.1% (15.2% for females and 4.7% for males). Among patients with normal random albumin, there were 20.0% (27.3% of females and 10.7% of males) patients with NAP. The prevalence of NAP in the timed samples group was 24.6% (29.8% for females and 18.5% for males). Among patients with normal timed urine albumin, there were 36.2% (40.0% of females and 30.8% of males) patients with NAP. There was a strong positive association with female gender and NAP in most patients groups. Testing for only urine (micro)albumin can miss up to 40% of females and 30.8% of males with gross proteinuria. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Diagnostic value and cost utility analysis for urine Gram stain and urine microscopic examination as screening tests for urinary tract infection.

    PubMed

    Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn

    2005-06-01

    The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.

  16. Characterization of ultrafiltration of undiluted and diluted stored urine.

    PubMed

    Ouma, J; Septien, S; Velkushanova, K; Pocock, J; Buckley, C

    2016-11-01

    Urine ultrafiltration (UF) was studied in terms of flux, permeability, resistance and fouling. Two types of samples were used: stored urine representing the feedstock obtained from urine diversion dry toilets; and diluted stored urine representing the feedstock obtained from urinals. Three different filtration experiment sets were adopted in this study. For the first case, pressure was set in an ascending order, i.e. from 10 to 60 kPa during filtration of stored urine. For the second case, pressure was set in a descending order, i.e. from 60 to 10 kPa for the same feed stream. The third case involved filtration of diluted urine with pressure in ascending order, i.e. from 10 to 60 kPa. The results indicated that diluted urine had higher flux than undiluted urine with maximum values of 43 and 26 L·m -2 ·h -1 respectively. Cake formation was the dominating fouling mechanism during urine filtration with a contribution of about 90% to the total hydraulic resistance. The contribution of chemically irreversible fouling was low (-2%), unless operating from high to low pressures. Indeed, irreversible fouling appeared to be greater during the experiments starting at higher pressure. Although undiluted urine had a higher fouling potential compared to diluted urine, the specific cake resistance was higher for diluted urine, probably due to a denser cake caused by lower particle sizes in that sample. The permeate obtained after urine filtration had much lower suspended solids content compared to the feedstock, with rejections up to 99%. The concentration of the ionic species remained unchanged, and 75% of the organic compounds and dissolved solids remained in the permeate. Urine UF could then be used as pre-treatment to remove suspended solids.

  17. A pilot study to assess if urine specific gravity and urine colour charts are useful indicators of dehydration in acute stroke patients.

    PubMed

    Rowat, Anne; Smith, Laura; Graham, Cat; Lyle, Dawn; Horsburgh, Dorothy; Dennis, Martin

    2011-09-01

    The purpose of this pilot study was to examine whether urine specific gravity and urine colour could provide an early warning of dehydration in stroke patients compared with standard blood indicators of hydration status. Dehydration after stroke has been associated with increased blood viscosity, venous thrombo-embolism and stroke mortality at 3-months. Earlier identification of dehydration might allow us to intervene to prevent significant dehydration developing or reduce its duration to improve patient outcomes. We recruited 20 stroke patients in 2007 and measured their urine specific gravity with urine test strips, a refractometer, and urine colour of specimens taken daily on 10 consecutive days and compared with the routine blood urea:creatinine ratios over the same period to look for trends and relationships over time. The agreement between the refractometer, test strips and urine colour were expressed as a percentage with 95% confidence intervals. Nine (45%) of the 20 stroke patients had clinical signs of dehydration and had a significantly higher admission median urea:creatinine ratio (P = 0·02, Mann-Whitney U-test). There were no obvious relationships between urine specific gravity and urine colour with the urea:creatinine ratio. Of the 174 urine samples collected, the refractometer agreed with 70/174 (40%) urine test strip urine specific gravity and 117/174 (67%) urine colour measurements. Our results do not support the use of the urine test strip urine specific gravity as an early indicator of dehydration. Further research is required to develop a practical tool for the early detection of dehydration in stroke patients. © 2011 Blackwell Publishing Ltd.

  18. Determination of urine-derived odorous compounds in a source separation sanitation system.

    PubMed

    Liu, Bianxia; Giannis, Apostolos; Chen, Ailu; Zhang, Jiefeng; Chang, Victor W C; Wang, Jing-Yuan

    2017-02-01

    Source separation sanitation systems have attracted more and more attention recently. However, separate urine collection and treatment could induce odor issues, especially in large scale application. In order to avoid such issues, it is necessary to monitor the odor related compounds that might be generated during urine storage. This study investigated the odorous compounds that emitted from source-separated human urine under different hydrolysis conditions. Batch experiments were conducted to investigate the effect of temperature, stale/fresh urine ratio and urine dilution on odor emissions. It was found that ammonia, dimethyl disulfide, allyl methyl sulfide and 4-heptanone were the main odorous compounds generated from human urine, with headspace concentrations hundreds of times higher than their respective odor thresholds. Furthermore, the high temperature accelerated urine hydrolysis and liquid-gas mass transfer, resulting a remarkable increase of odor emissions from the urine solution. The addition of stale urine enhanced urine hydrolysis and expedited odor emissions. On the contrary, diluted urine emitted less odorous compounds ascribed to reduced concentrations of odorant precursors. In addition, this study quantified the odor emissions and revealed the constraints of urine source separation in real-world applications. To address the odor issue, several control strategies are recommended for odor mitigation or elimination from an engineering perspective. Copyright © 2016. Published by Elsevier B.V.

  19. A large-scale intercomparison of stratospheric vertical distributions of NO2 and BrO retrieved from the SCIAMACHY limb measurements and ground-based twilight observations

    NASA Astrophysics Data System (ADS)

    Rozanov, Alexei; Hendrick, Francois; Lotz, Wolfhardt; van Roozendael, Michel; Bovensmann, Heinrich; Burrows, John P.

    This study is devoted to the intercomparison of NO2 and BrO vertical profiles obtained from the satellite and ground-based measurements. Although, the ground-based observations are performed only at selected locations, they have a great potential to be used for the validation of satellite measurements since continuous long-term measurement series performed with the same instruments are available. Thus, long-term trends in the observed species can be analyzed and intercompared. Previous intercomparisons of the vertical distributions of NO2 and BrO retrieved from SCIAMACHY limb measurements at the University of Bremen and obtained at IASB-BIRA by applying a profiling technique to ground-based zenith-sky DOAS observations have shown a good agreement between the results of completely different measurement techniques. However, only a relatively short time period of one year was analyzed so far which do not allow investigating seasonal variations and trends. Furthermore, some minor discrepancies are still to be analyzed. In the current study, several years datasets obtained at Observatoire de Haute-Provence (OHP) in France and in Harestua in Norway will be compared to the retrievals of SCIAMACHY limb measurements. Seasonal and annual variations will be analyzed and possible reasons for the remaining discrepancies will be discussed.

  20. Constraints and potentials of future irrigation water availability on agricultural production under climate change

    PubMed Central

    Elliott, Joshua; Deryng, Delphine; Müller, Christoph; Frieler, Katja; Konzmann, Markus; Gerten, Dieter; Glotter, Michael; Flörke, Martina; Wada, Yoshihide; Best, Neil; Eisner, Stephanie; Fekete, Balázs M.; Folberth, Christian; Foster, Ian; Gosling, Simon N.; Haddeland, Ingjerd; Khabarov, Nikolay; Ludwig, Fulco; Masaki, Yoshimitsu; Olin, Stefan; Rosenzweig, Cynthia; Ruane, Alex C.; Satoh, Yusuke; Schmid, Erwin; Stacke, Tobias; Tang, Qiuhong; Wisser, Dominik

    2014-01-01

    We compare ensembles of water supply and demand projections from 10 global hydrological models and six global gridded crop models. These are produced as part of the Inter-Sectoral Impacts Model Intercomparison Project, with coordination from the Agricultural Model Intercomparison and Improvement Project, and driven by outputs of general circulation models run under representative concentration pathway 8.5 as part of the Fifth Coupled Model Intercomparison Project. Models project that direct climate impacts to maize, soybean, wheat, and rice involve losses of 400–1,400 Pcal (8–24% of present-day total) when CO2 fertilization effects are accounted for or 1,400–2,600 Pcal (24–43%) otherwise. Freshwater limitations in some irrigated regions (western United States; China; and West, South, and Central Asia) could necessitate the reversion of 20–60 Mha of cropland from irrigated to rainfed management by end-of-century, and a further loss of 600–2,900 Pcal of food production. In other regions (northern/eastern United States, parts of South America, much of Europe, and South East Asia) surplus water supply could in principle support a net increase in irrigation, although substantial investments in irrigation infrastructure would be required. PMID:24344283

  1. The First SIMBIOS Radiometric Intercomparison (SIMRIC-1), April-September 2001

    NASA Technical Reports Server (NTRS)

    Meister, Gerhard; Abel, Peter; McClain, Charles; Barnes, Robert; Fargion, Giulietta; Cooper, John; Davis, Curtiss; Korwan, Daniel; Godin, Mike; Maffione, Robert

    2002-01-01

    This report describes the first SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) Radiometric Intercomparison (SIMRIC-1). The purpose of the SIMRIC-1 is to ensure a common radiometric scale of the calibration facilities that are engaged in calibrating in situ radiometers used for ocean color related research and to document the calibration procedures and protocols. SIMBIOS staff visited the seven participating laboratories for at least two days each. The SeaWiFS Transfer Radiometer SXR-II measured the calibration radiances produced in the laboratories. The measured radiances were compared with the radiances expected by the laboratories. Typically, the measured radiances were higher than the expected radiances by 0 to 2%. This level of agreement is satisfactory. Several issues were identified, where the calibration protocols need to be improved, especially the reflectance calibration of the reference plaques and the distance correction when using the irradiance standards at distances greater than the 50 cm. The responsivity of the SXR-II changed between 0.3% (channel 6) and 1.6% (channel 2) from December 2000 to December 2001. Monitoring the SXR-II with a portable light source showed a linear drift of the calibration, except for channel 1, where a 2% drop occurred in summer.

  2. IPRT polarized radiative transfer model intercomparison project - Phase A

    NASA Astrophysics Data System (ADS)

    Emde, Claudia; Barlakas, Vasileios; Cornet, Céline; Evans, Frank; Korkin, Sergey; Ota, Yoshifumi; Labonnote, Laurent C.; Lyapustin, Alexei; Macke, Andreas; Mayer, Bernhard; Wendisch, Manfred

    2015-10-01

    The polarization state of electromagnetic radiation scattered by atmospheric particles such as aerosols, cloud droplets, or ice crystals contains much more information about the optical and microphysical properties than the total intensity alone. For this reason an increasing number of polarimetric observations are performed from space, from the ground and from aircraft. Polarized radiative transfer models are required to interpret and analyse these measurements and to develop retrieval algorithms exploiting polarimetric observations. In the last years a large number of new codes have been developed, mostly for specific applications. Benchmark results are available for specific cases, but not for more sophisticated scenarios including polarized surface reflection and multi-layer atmospheres. The International Polarized Radiative Transfer (IPRT) working group of the International Radiation Commission (IRC) has initiated a model intercomparison project in order to fill this gap. This paper presents the results of the first phase A of the IPRT project which includes ten test cases, from simple setups with only one layer and Rayleigh scattering to rather sophisticated setups with a cloud embedded in a standard atmosphere above an ocean surface. All scenarios in the first phase A of the intercomparison project are for a one-dimensional plane-parallel model geometry. The commonly established benchmark results are available at the IPRT website.

  3. The 1994 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers

    PubMed Central

    Thompson, Ambler; Early, Edward A.; DeLuisi, John; Disterhoft, Patrick; Wardle, David; Kerr, James; Rives, John; Sun, Yongchen; Lucas, Timothy; Mestechkina, Tanya; Neale, Patrick

    1997-01-01

    Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, the first North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held September 19–29, 1994 at Table Mountain outside Boulder, Colorado, USA. This Intercomparison was coordinated by the National Institute of Standards and Technology and the National Oceanic and Atmospheric Administration (NOAA). Participating agencies were the Environmental Protection Agency, National Science Foundation, Smithsonian Environmental Research Center, and Atmospheric Environment Service, Canada. Instruments were characterized for wavelength accuracy, bandwidth, stray-light rejection, and spectral irradiance responsivity, the latter with a NIST standard lamp calibrated to operate in the horizontal position. The spectral irradiance responsivity was determined once indoors and twice outdoors, and demonstrated that, while the responsivities changed upon moving the instruments, they were relatively stable when the instruments remained outdoors. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST standard lamp, and a simple convolution technique to account for the different bandwidths of the instruments, the measured solar irradiances agreed within 5 %. PMID:27805148

  4. LLNL Results from CALIBAN-PROSPERO Nuclear Accident Dosimetry Experiments in September 2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lobaugh, M. L.; Hickman, D. P.; Wong, C. W.

    2015-05-21

    Lawrence Livermore National Laboratory (LLNL) uses thin neutron activation foils, sulfur, and threshold energy shielding to determine neutron component doses and the total dose from neutrons in the event of a nuclear criticality accident. The dosimeter also uses a DOELAP accredited Panasonic UD-810 (Panasonic Industrial Devices Sales Company of America, 2 Riverfront Plaza, Newark, NJ 07102, U.S.A.) thermoluminescent dosimetery system (TLD) for determining the gamma component of the total dose. LLNL has participated in three international intercomparisons of nuclear accident dosimeters. In October 2009, LLNL participated in an exercise at the French Commissariat à l’énergie atomique et aux énergies alternativesmore » (Alternative Energies and Atomic Energy Commission- CEA) Research Center at Valduc utilizing the SILENE reactor (Hickman, et.al. 2010). In September 2010, LLNL participated in a second intercomparison at CEA Valduc, this time with exposures at the CALIBAN reactor (Hickman et al. 2011). This paper discusses LLNL’s results of a third intercomparison hosted by the French Institut de Radioprotection et de Sûreté Nucléaire (Institute for Radiation Protection and Nuclear Safety- IRSN) with exposures at two CEA Valduc reactors (CALIBAN and PROSPERO) in September 2014. Comparison results between the three participating facilities is presented elsewhere (Chevallier 2015; Duluc 2015).« less

  5. An intercomparison of instrumentation for tropospheric measurements of dimethyl sulfide: Aircraft results for concentrations at the parts-per-trillion level

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Warren, Linda S.; Davis, Douglas D.; Andreae, Meinrat O.; Bandy, Alan R.; Ferek, Ronald J.; Johnson, James E.; Saltzman, Eric S.; Cooper, David J.

    1993-01-01

    This paper reports results from NASA's Chemical Instrumentation and Test Evaluation (CITE 3) during which airborne measurements of dimethyl sulfide (DMS) from six instruments were intercompared. Represented by the six instruments are three fundamentally different detection principles (flame photometric, mass spectrometric, and electron capture after fluorination); three collection/preconcentration methods (cryogenic, gold wool absorption, and polymer absorbent); and three types of oxidant scrubbers (solid phase alkaline, aqueous reactor, and cotton). The measurements were made over the Atlantic Ocean in August/September 1989 during flights from NASA's Wallops Flight Center, Virginia, and Natal, Brazil. The majority of the intercomparisons are at DMS mixing ratios less than 50 pptv. Results show that instrument agreement is of the order of a few pptv for mixing ratios less than 50 pptv and to within about 15% above 50 pptv. Statistically significant (95% confidence) measurement biases were noted among some of the techniques. However, in all cases, any bias is small and within the accuracy of the measurements and prepared DMS standards. Thus, we conclude that the techniques intercompared during CITE 3 provide equally valid measurements of DMS in the range of a few pptv to 100 pptv (upper range of the intercomparisons).

  6. Large-Scale Features of Pliocene Climate: Results from the Pliocene Model Intercomparison Project

    NASA Technical Reports Server (NTRS)

    Haywood, A. M.; Hill, D.J.; Dolan, A. M.; Otto-Bliesner, B. L.; Bragg, F.; Chan, W.-L.; Chandler, M. A.; Contoux, C.; Dowsett, H. J.; Jost, A.; hide

    2013-01-01

    Climate and environments of the mid-Pliocene warm period (3.264 to 3.025 Ma) have been extensively studied.Whilst numerical models have shed light on the nature of climate at the time, uncertainties in their predictions have not been systematically examined. The Pliocene Model Intercomparison Project quantifies uncertainties in model outputs through a coordinated multi-model and multi-mode data intercomparison. Whilst commonalities in model outputs for the Pliocene are clearly evident, we show substantial variation in the sensitivity of models to the implementation of Pliocene boundary conditions. Models appear able to reproduce many regional changes in temperature reconstructed from geological proxies. However, data model comparison highlights that models potentially underestimate polar amplification. To assert this conclusion with greater confidence, limitations in the time-averaged proxy data currently available must be addressed. Furthermore, sensitivity tests exploring the known unknowns in modelling Pliocene climate specifically relevant to the high latitudes are essential (e.g. palaeogeography, gateways, orbital forcing and trace gasses). Estimates of longer-term sensitivity to CO2 (also known as Earth System Sensitivity; ESS), support previous work suggesting that ESS is greater than Climate Sensitivity (CS), and suggest that the ratio of ESS to CS is between 1 and 2, with a "best" estimate of 1.5.

  7. The Second SIMBIOS Radiometric Intercomparison (SIMRIC-2), March-November 2002. Volume 2

    NASA Technical Reports Server (NTRS)

    Meister, Gerhard; Abel, Peter; Carder, Kendall; Chapin, Albert; Clark, Dennis; Cooper, John; Davis, Curtis; English, David; Fargion, Giulietta; Feinholz, Michael; hide

    2003-01-01

    The second SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) Radiometric Intercomparison (SIMRIC-2) was carried out in 2002. The purpose of the SIMRIC's was to ensure a common radiometric scale among the calibration facilities that are engaged in calibrating in-situ radiometrics used for ocean color-related research and to document the calibration procedures and protocols. The SeaWIFS Transfer Radiometer (SXR-II) measured the calibration radiances at six wavelengths from 411nm to 777nm in the ten laboratories participating in the SIMRIC-2. The measured radiances were compared with the radiances expected by the laboratories. The agreement was within the combined uncertainties for all but two laboratories. Likely error sources were identified in these laboratories and corrective measures were implemented. NIST calibrations in December 2001 and January 2003 showed changes ranging from -0.6% to +0.7% for the six SXR-II channels. Two independent light sources were used to monitor changes in the SXR-II responsivity between the NIST calibrations. A 2% variation of the responsivity of channel 1 of the SXR-II was detected, and the SXR-II responsivity was corrected using the monitoring data. This report also compared directional reflectance calibrations of a Spectralon plaque by different calibration facilities

  8. A novel way to monitor urine concentration: fluorescent concentration matrices.

    PubMed

    Dubayova, Katarina; Luckova, Iveta; Sabo, Jan; Karabinos, Anton

    2015-01-01

    The amount of water found in urine is important diagnostic information; nevertheless it is not yet directly determined. Indirectly, the water content in urine is expressed by its density (specific gravity). However, without the diuresis value it is not possible to determine whether the increase in density of urine is due to a decrease in water secretion or an increase in the concentration of secreted substances. This problem can be solved by the use of fluorescent concentration 3D-matrices which characterise urine concentration through the pφ (or -logφ) value of the first fluorescence centre. The urine fluorescent concentration 3D-matrix was created by the alignment of the synchronous spectra of the dilution series of urine starting from undiluted (pφ = 0) to 1000-fold diluted urine (pφ = 3). Using the fluorescence concentration 3D-matrix analysis of the urine samples from healthy individuals, a reference range was established for the value pφ, determining the normal, concentrated or diluted type of urine. The diagnostic potential of this approach was tested on urine samples from two patients with a chronic glomerulonephritis. The pφ value of the urine fluorescence concentration 3D-matrix analysis determines whether the urine sample falls within the normal, concentrated or diluted type of urine. This parameter can be directly utilised in sportsmen's hydration state monitoring, as well as in the diagnosis and treatment of serious diseases. An important advantage of this novel diagnostic approach is that a 12/24 h urine collection is not required, which predetermines it for use especially within paediatrics.

  9. Postoperative Biomarkers Predict Acute Kidney Injury and Poor Outcomes after Pediatric Cardiac Surgery

    PubMed Central

    Devarajan, Prasad; Zappitelli, Michael; Sint, Kyaw; Thiessen-Philbrook, Heather; Li, Simon; Kim, Richard W.; Koyner, Jay L.; Coca, Steven G.; Edelstein, Charles L.; Shlipak, Michael G.; Garg, Amit X.; Krawczeski, Catherine D.

    2011-01-01

    Acute kidney injury (AKI) occurs commonly after pediatric cardiac surgery and associates with poor outcomes. Biomarkers may help the prediction or early identification of AKI, potentially increasing opportunities for therapeutic interventions. Here, we conducted a prospective, multicenter cohort study involving 311 children undergoing surgery for congenital cardiac lesions to evaluate whether early postoperative measures of urine IL-18, urine neutrophil gelatinase-associated lipocalin (NGAL), or plasma NGAL could identify which patients would develop AKI and other adverse outcomes. Urine IL-18 and urine and plasma NGAL levels peaked within 6 hours after surgery. Severe AKI, defined by dialysis or doubling in serum creatinine during hospital stay, occurred in 53 participants at a median of 2 days after surgery. The first postoperative urine IL-18 and urine NGAL levels strongly associated with severe AKI. After multivariable adjustment, the highest quintiles of urine IL-18 and urine NGAL associated with 6.9- and 4.1-fold higher odds of AKI, respectively, compared with the lowest quintiles. Elevated urine IL-18 and urine NGAL levels associated with longer hospital stay, longer intensive care unit stay, and duration of mechanical ventilation. The accuracy of urine IL-18 and urine NGAL for diagnosis of severe AKI was moderate, with areas under the curve of 0.72 and 0.71, respectively. The addition of these urine biomarkers improved risk prediction over clinical models alone as measured by net reclassification improvement and integrated discrimination improvement. In conclusion, urine IL-18 and urine NGAL, but not plasma NGAL, associate with subsequent AKI and poor outcomes among children undergoing cardiac surgery. PMID:21836147

  10. Rapid spot tests for detecting the presence of adulterants in urine specimens submitted for drug testing.

    PubMed

    Dasgupta, Amitava; Wahed, Amer; Wells, Alice

    2002-02-01

    Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite, and "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity checks (pH, specific gravity, and temperature). We developed rapid spot tests for detecting these adulterants in urine. Addition of 3% hydrogen peroxide in urine adulterated with PCC caused rapid formation of a dark brown color. In contrast, unadulterated urine turned colorless when hydrogen peroxide was added. When urine contaminated with nitrite and 2 to 3 drops of 2N hydrochloric acid were added to 2% aqueous potassium permanganate solution, the dark pink permanganate solution turned colorless immediately with effervescence. Urine contaminated with nitrite liberated iodine from potassium iodide solution in the presence of 2N hydrochloric acid. Urine adulterated with PCC also liberated iodine from potassium iodide in acid medium but did not turn potassium permanganate solution colorless. Urine specimens from volunteers and random urine samples that tested negative for drugs did not cause false-positive results. These rapid spot tests are useful for detecting adulterated urine to avoid false-negative drug tests.

  11. Alkaline dehydration of anion-exchanged human urine: Volume reduction, nutrient recovery and process optimisation.

    PubMed

    Simha, Prithvi; Senecal, Jenna; Nordin, Annika; Lalander, Cecilia; Vinnerås, Björn

    2018-06-02

    In urine-separating sanitation systems, bacterial urease enzymes can hydrolyse urea to ammonia during the pipe transport and storage of urine. The present study investigated whether it was possible to reduce the urine volume without losing the nitrogen as ammonia. A method for stabilising the urine prior to dehydration was developed. Briefly, fresh human urine was stabilised by passage through an anion-exchanger, added to an alkaline media (wood ash or alkalised biochar), and dehydrated. Urine dehydration was investigated at three temperatures: 40, 45 and 50 °C. The influence of various factors affecting the dehydration process was modelled and the rate of urine dehydration was optimised. Results indicated that 75% (v/v) of the urine has to pass through the ion-exchanger for alkaline stabilisation of urine to occur. At all investigated temperatures, the dehydrator accomplished >90% volume reduction of ion-exchanged urine, > 70% N retention and 100% recovery of P and K. To realise high degree of nutrient valorisation, this study proposes combining source-separation of human urine with alkaline dehydration. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Urine separating sewage systems--environmental effects and resource usage.

    PubMed

    Jönsson, H

    2002-01-01

    Effects of urine separation on the environment and resource usage were estimated using the simulation package ORWARE. Measurements on the urine-separating system in the housing district Palsternackan in Stockholm and on the fertilising effect of the urine were used in the simulations. The tenants were at home 65% of the time and separated 65% of the urine. Under these conditions, urine separation decreased the waterborne emissions of nitrogen and phosphorus by 55% and 33% respectively. Compared to the conventional system, urine separation increased the flow from the wastewater system to agriculture of plant-available nitrogen by a factor of 28, phosphorus by a factor of 1.35 and potassium by a factor of 23. Urine is a well-balanced complete fertiliser with very low concentrations of heavy metals. Urine separation conserved energy as long as the urine was transported distances shorter than 221 km to the field with a truck and trailer. If all the urine had been separated and transported only 1 km, the energy saving would have been 36%. In this and in previous studies, urine separation proved to be an improvement over the conventional system as regards environmental effects and resource usage.

  13. Comparison of urine specimen collection times and testing fractions for the detection of high-risk human papillomavirus and high-grade cervical precancer.

    PubMed

    Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S

    2016-01-01

    Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Methods for Validation and Intercomparison of Remote Sensing and In situ Ice Water Measurements: Case Studies from CRYSTAL-FACE and Model Results

    NASA Technical Reports Server (NTRS)

    Sayres, D.S.; Pittman, J. V.; Smith, J. B.; Weinstock, E. M.; Anderson, J. G.; Heymsfield, G.; Li, L.; Fridlind, A.; Ackerman, A. S.

    2004-01-01

    Remote sensing observations, such as those from AURA, are necessary to understand the role of cirrus in determining the radiative and humidity budgets of the upper troposphere. Using these measurements quantitatively requires comparisons with in situ measurements that have previously been validated. However, a direct comparison of remote and in situ measurements is difficult due to the requirement that the spatial and temporal overlap be sufficient in order to guarantee that both instruments are measuring the same air parcel. A difficult as this might be for gas phase intercomparisons, cloud inhomogeneities significantly exacerbate the problem for cloud ice water content measurements. The CRYSTAL-FACE mission provided an opportunity to assess how well such intercomparisons can be performed and to establish flight plans that will be necessary for validation of future satellite instruments. During CRYSTAL-FACE, remote and in situ instruments were placed on different aircraft (NASA's ER-2 and WB-59, and the two planes flew in tandem so that the in situ payload flew in the field of view of the remote instruments. We show here that, even with this type of careful flight planning, it is not always possible to guarantee that remote and in situ instruments are viewing the same air parcel. We use ice water data derived from the in situ Harvard Total Water (HV-TW) instrument, and the remote Goddard Cloud Radar System (CRS) and show that agreement between HV-TW and CRS is a strong function of the horizontal separation and the time delay between the aircraft transects. We also use a cloud model to simulate possible trajectories through a cloud and evaluate the use of statistical analysis in determining the agreement between the two instruments. This type of analysis should guide flight planning for future intercomparison efforts, whether for aircraft or satellite-borne instrumentation.

  15. The North American Carbon Program Multi-scale Synthesis and Terrestrial Model Intercomparison Project – Part 2: Environmental driver data

    DOE PAGES

    Wei, Yaxing; Liu, Shishi; Huntzinger, Deborah N.; ...

    2014-12-05

    Ecosystems are important and dynamic components of the global carbon cycle, and terrestrial biospheric models (TBMs) are crucial tools in further understanding of how terrestrial carbon is stored and exchanged with the atmosphere across a variety of spatial and temporal scales. Improving TBM skills, and quantifying and reducing their estimation uncertainties, pose significant challenges. The Multi-scale Synthesis and Terrestrial Model Intercomparison Project (MsTMIP) is a formal multi-scale and multi-model intercomparison effort set up to tackle these challenges. The MsTMIP protocol prescribes standardized environmental driver data that are shared among model teams to facilitate model model and model observation comparisons. Inmore » this article, we describe the global and North American environmental driver data sets prepared for the MsTMIP activity to both support their use in MsTMIP and make these data, along with the processes used in selecting/processing these data, accessible to a broader audience. Based on project needs and lessons learned from past model intercomparison activities, we compiled climate, atmospheric CO 2 concentrations, nitrogen deposition, land use and land cover change (LULCC), C3 / C4 grasses fractions, major crops, phenology and soil data into a standard format for global (0.5⁰ x 0.5⁰ resolution) and regional (North American: 0.25⁰ x 0.25⁰ resolution) simulations. In order to meet the needs of MsTMIP, improvements were made to several of the original environmental data sets, by improving the quality, and/or changing their spatial and temporal coverage, and resolution. The resulting standardized model driver data sets are being used by over 20 different models participating in MsTMIP. Lastly, the data are archived at the Oak Ridge National Laboratory Distributed Active Archive Center (ORNL DAAC, http://daac.ornl.gov) to provide long-term data management and distribution.« less

  16. Real-time analysis of δ13C- and δD-CH4 in ambient air with laser spectroscopy: method development and first intercomparison results

    NASA Astrophysics Data System (ADS)

    Eyer, S.; Tuzson, B.; Popa, M. E.; van der Veen, C.; Röckmann, T.; Rothe, M.; Brand, W. A.; Fisher, R.; Lowry, D.; Nisbet, E. G.; Brennwald, M. S.; Harris, E.; Zellweger, C.; Emmenegger, L.; Fischer, H.; Mohn, J.

    2015-08-01

    In situ and simultaneous measurement of the three most abundant isotopologues of methane using mid-infrared laser absorption spectroscopy is demonstrated. A field-deployable, autonomous platform is realized by coupling a compact quantum cascade laser absorption spectrometer (QCLAS) to a preconcentration unit, called TRace gas EXtractor (TREX). This unit enhances CH4 mole fractions by a factor of up to 500 above ambient levels and quantitatively separates interfering trace gases such as N2O and CO2. The analytical precision of the QCLAS isotope measurement on the preconcentrated (750 ppm, parts-per-million, μmole/mole) methane is 0.1 and 0.5 ‰ for δ13C- and δD-CH4 at 10 min averaging time. Based on replicate measurements of compressed air during a two-week intercomparison campaign, the repeatability of the TREX-QCLAS was determined to be 0.19 and 1.9 ‰ for δ13C and δD-CH4, respectively. In this intercomparison campaign the new in situ technique is compared to isotope-ratio mass-spectrometry (IRMS) based on glass flask and bag sampling and real time CH4 isotope analysis by two commercially available laser spectrometers. Both laser-based analyzers were limited to methane mole fraction and δ13C-CH4 analysis, and only one of them, a cavity ring down spectrometer, was capable to deliver meaningful data for the isotopic composition. After correcting for scale offsets, the average difference between TREX-QCLAS data and bag/flask sampling-IRMS values are within the extended WMO compatibility goals of 0.2 and 5 ‰ for δ13C- and δD-CH4, respectively. Thus, the intercomparison also reveals the need for reference air samples with accurately determined isotopic composition of CH4 to further improve the interlaboratory compatibility.

  17. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriguez, Branelle R.; Broyan, James Lee, Jr.

    2008-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  18. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Cibuzar, Branelle R.; Broyan, James Lee, Jr.

    2009-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  19. Urine Pretreat Injection System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    A new method of introducing the OXONE (Registered Trademark) Monopersulfate Compound for urine pretreat into a two-phase urine/air flow stream has been successfully tested and evaluated. The feasibility of this innovative method has been established for purposes of providing a simple, convenient, and safe method of handling a chemical pretreat required for urine processing in a microgravity space environment. Also, the Oxone portion of the urine pretreat has demonstrated the following advantages during real time collection of 750 pounds of urine in a Space Station design two-phase urine Fan/Separator: Eliminated urine precipitate buildup on internal hardware and plumbing; Minimized odor from collected urine; and Virtually eliminated airborne bacteria. The urine pretreat, as presently defined for the Space Station program for proper downstream processing of urine, is a two-part chemical treatment of 5.0 grams of Oxone and 2.3 ml of H2SO4 per liter of urine. This study program and test demonstrated only the addition of the proper ratio of Oxone into the urine collection system upstream of the Fan/Separator. This program was divided into the following three major tasks: (1) A trade study, to define and recommend the type of Oxone injection method to pursue further; (2) The design and fabrication of the selected method; and (3) A test program using high fidelity hardware and fresh urine to demonstrate the method feasibility. The trade study was conducted which included defining several methods for injecting Oxone in different forms into a urine system. Oxone was considered in a liquid, solid, paste and powered form. The trade study and the resulting recommendation were presented at a trade study review held at Hamilton Standard on 24-25 October 94. An agreement was reached at the meeting to continue the solid tablet in a bag concept which included a series of tablets suspended in the urine/air flow stream. These Oxone tablets would slowly dissolve at a controlled rate providing the proper concentration in the collected urine. To implement the solid tablet in a bag approach, a design concept was completed with prototype drawings of the complete urine pretreat prefilter assembly. A successful fabrication technique was developed for retaining the Oxone tablets in a fabric casing attached to the end of the existing Space Station Waste Collection System urine prefilter assembly. The final pretreat prefilter configuration held sufficient Oxone in a tablet form to allow normal scheduled daily (or twice daily) change out of the urine filter depending on the use rate of the Space Station urine collection system. The actual tests to prove the concept were conducted using the Urine Fan/Separator assembly that was originally used in the STS-52 Design Test Objective (DTO) urinal assembly. Other related tests were conducted to demonstrate the actual minimum ratio of Oxone to urine that will control microbial growth.

  20. An assessment of two automated snow water equivalent instruments during the WMO Solid Precipitation Intercomparison Experiment

    NASA Astrophysics Data System (ADS)

    Smith, Craig D.; Kontu, Anna; Laffin, Richard; Pomeroy, John W.

    2017-01-01

    During the World Meteorological Organization (WMO) Solid Precipitation Intercomparison Experiment (SPICE), automated measurements of snow water equivalent (SWE) were made at the Sodankylä (Finland), Weissfluhjoch (Switzerland) and Caribou Creek (Canada) SPICE sites during the northern hemispheric winters of 2013/14 and 2014/15. Supplementary intercomparison measurements were made at Fortress Mountain (Kananaskis, Canada) during the 2013/14 winter. The objectives of this analysis are to compare automated SWE measurements with a reference, comment on their performance and, where possible, to make recommendations on how to best use the instruments and interpret their measurements. Sodankylä, Caribou Creek and Fortress Mountain hosted a Campbell Scientific CS725 passive gamma radiation SWE sensor. Sodankylä and Weissfluhjoch hosted a Sommer Messtechnik SSG1000 snow scale. The CS725 operating principle is based on measuring the attenuation of soil emitted gamma radiation by the snowpack and relating the attenuation to SWE. The SSG1000 measures the mass of the overlying snowpack directly by using a weighing platform and load cell. Manual SWE measurements were obtained at the intercomparison sites on a bi-weekly basis over the accumulation-ablation periods using bulk density samplers. These manual measurements are considered to be the reference for the intercomparison. Results from Sodankylä and Caribou Creek showed that the CS725 generally overestimates SWE as compared to manual measurements by roughly 30-35 % with correlations (r2) as high as 0.99 for Sodankylä and 0.90 for Caribou Creek. The RMSE varied from 30 to 43 mm water equivalent (mm w.e.) and from 18 to 25 mm w.e. at Sodankylä and Caribou Creek, which had respective SWE maximums of approximately 200 and 120 mm w.e. The correlation at Fortress Mountain was 0.94 (RMSE of 48 mm w.e. with a maximum SWE of approximately 650 mm w.e.) with no systematic overestimation. The SSG1000 snow scale, having a different measurement principle, agreed quite closely with the manual measurements at Sodankylä and Weissfluhjoch throughout the periods when data were available (r2 as high as 0.99 and RMSE from 8 to 24 mm w.e. at Sodankylä and from 56 to 59 mm w.e. at Weissfluhjoch, where maximum SWE was approximately 850 mm w.e.). When the SSG1000 was compared to the CS725 at Sodankylä, the agreement was linear until the start of ablation when the positive bias in the CS725 increases substantially relative to the SSG1000. Since both Caribou Creek and Sodankylä have sandy soil, water from the snowpack readily infiltrates into the soil during melt, even if the soil is frozen. However, the CS725 does not differentiate this water from the unmelted snow. This issue can be identified, at least during the late spring ablation period, with soil moisture and temperature observations like those measured at Caribou Creek. With a less permeable soil and surface runoff, the increase in the instrument bias during ablation is not as significant, as shown by the Fortress Mountain intercomparison.

  1. Urine Test: Microalbumin-to-Creatinine Ratio (For Parents)

    MedlinePlus

    ... involves measuring the amount of a protein called albumin in the urine (pee). The amount of urine albumin is compared with the quantity of a waste ... steady rate, so comparing the ratio of urine albumin with creatinine in the same urine specimen helps ...

  2. Urine Concentration and Pyuria for Identifying UTI in Infants.

    PubMed

    Chaudhari, Pradip P; Monuteaux, Michael C; Bachur, Richard G

    2016-11-01

    Varying urine white blood cell (WBC) thresholds have been recommended for the presumptive diagnosis of urinary tract infection (UTI) among young infants. These thresholds have not been studied with newer automated urinalysis systems that analyze uncentrifuged urine that might be influenced by urine concentration. Our objective was to determine the optimal urine WBC threshold for UTI in young infants by using an automated urinalysis system, stratified by urine concentration. Retrospective cross-sectional study of infants aged <3 months evaluated for UTI in the emergency department with paired urinalysis and urine culture. UTI was defined as ≥50 000 colony-forming units/mL from catheterized specimens. Test characteristics were calculated across a range of WBC and leukocyte esterase (LE) cut-points, dichotomized into specific gravity groups (dilute <1.015; concentrated ≥1.015). Twenty-seven thousand infants with a median age of 1.7 months were studied. UTI prevalence was 7.8%. Optimal WBC cut-points were 3 WBC/high-power field (HPF) in dilute urine (likelihood ratio positive [LR+] 9.9, likelihood ratio negative [LR‒] 0.15) and 6 WBC/HPF (LR+ 10.1, LR‒ 0.17) in concentrated urine. For dipstick analysis, positive LE has excellent test characteristics regardless of urine concentration (LR+ 22.1, LR‒ 0.12 in dilute urine; LR+ 31.6, LR‒ 0.22 in concentrated urine). Urine concentration should be incorporated into the interpretation of automated microscopic urinalysis in young infants. Pyuria thresholds of 3 WBC/HPF in dilute urine and 6 WBC/HPF in concentrated urine are recommended for the presumptive diagnosis of UTI. Without correction of specific gravity, positive LE by automated dipstick is a reliably strong indicator of UTI. Copyright © 2016 by the American Academy of Pediatrics.

  3. Use of a midstream clean catch mobile application did not lower urine contamination rates in an ED.

    PubMed

    Jacob, Mary S; Kulie, Paige; Benedict, Cameron; Ordoobadi, Alexander J; Sikka, Neal; Steinmetz, Erika; McCarthy, Melissa L

    2018-01-01

    Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure

    PubMed Central

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2018-01-01

    Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162

  5. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    PubMed

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  7. Adulterants in Urine Drug Testing.

    PubMed

    Fu, S

    Urine drug testing plays an important role in monitoring licit and illicit drug use for both medico-legal and clinical purposes. One of the major challenges of urine drug testing is adulteration, a practice involving manipulation of a urine specimen with chemical adulterants to produce a false negative test result. This problem is compounded by the number of easily obtained chemicals that can effectively adulterate a urine specimen. Common adulterants include some household chemicals such as hypochlorite bleach, laundry detergent, table salt, and toilet bowl cleaner and many commercial products such as UrinAid (glutaraldehyde), Stealth® (containing peroxidase and peroxide), Urine Luck (pyridinium chlorochromate, PCC), and Klear® (potassium nitrite) available through the Internet. These adulterants can invalidate a screening test result, a confirmatory test result, or both. To counteract urine adulteration, drug testing laboratories have developed a number of analytical methods to detect adulterants in a urine specimen. While these methods are useful in detecting urine adulteration when such activities are suspected, they do not reveal what types of drugs are being concealed. This is particularly the case when oxidizing urine adulterants are involved as these oxidants are capable of destroying drugs and their metabolites in urine, rendering the drug analytes undetectable by any testing technology. One promising approach to address this current limitation has been the use of unique oxidation products formed from reaction of drug analytes with oxidizing adulterants as markers for monitoring drug misuse and urine adulteration. This novel approach will ultimately improve the effectiveness of the current urine drug testing programs. © 2016 Elsevier Inc. All rights reserved.

  8. High LET, passive space radiation dosimetry and spectrometry

    NASA Technical Reports Server (NTRS)

    Benton, E. V.; Frank, A. L.; Benton, E. R.; Keegan, R. P.; Frigo, L. A.; Sanner, D.; Rowe, V.

    1995-01-01

    The development of high linear energy transfer (LET), passive radiation dosimetry and spectrometry is needed for the purpose of accurate determination of equivalent doses and assessment of health risks to astronauts on long duration missions. Progress in the following research areas is summerized: intercomparisons of cosmic ray equivalent dose and LET spectra measurements between STS missions and between astronauts; increases LET spectra measurement accuracy with ATAS; space radiation measurements for intercomparisons of passive (PNTD, TLD, TRND, Emulsion) and active (TEPC, RME-111) dosimeters; interaction of cosmic ray particles with nuclei in matter; radiation measurements after long duration space exposures; ground based dosimeter calibrations; neutron detector calibrations; radiation measurements on Soviet/Russian spacecraft; space radiation measurements under thin shielding; and space radiation.

  9. Earth orientation from lunar laser ranging and an error analysis of polar motion services

    NASA Technical Reports Server (NTRS)

    Dickey, J. O.; Newhall, X. X.; Williams, J. G.

    1985-01-01

    Lunar laser ranging (LLR) data are obtained on the basis of the timing of laser pulses travelling from observatories on earth to retroreflectors placed on the moon's surface during the Apollo program. The modeling and analysis of the LLR data can provide valuable insights into earth's dynamics. The feasibility to model accurately the lunar orbit over the full 13-year observation span makes it possible to conduct relatively long-term studies of variations in the earth's rotation. A description is provided of general analysis techniques, and the calculation of universal time (UT1) from LLR is discussed. Attention is also given to a summary of intercomparisons with different techniques, polar motion results and intercomparisons, and a polar motion error analysis.

  10. Test Bed Doppler Wind Lidar and Intercomparison Facility At NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Kavaya, Michael J.; Koch, Grady J.; Petros, Mulugeta; Barnes, Bruce W.; Beyon, Jeffrey; Amzajerdian, Farzin; Yu, Ji-Rong; Singh, Upendra N.

    2004-01-01

    State of the art 2-micron lasers and other lidar components under development by NASA are being demonstrated and validated in a mobile test bed Doppler wind lidar. A lidar intercomparison facility has been developed to ensure parallel alignment of up to 4 Doppler lidar systems while measuring wind. Investigations of the new components; their operation in a complete system; systematic and random errors; the hybrid (joint coherent and direct detection) approach to global wind measurement; and atmospheric wind behavior are planned. Future uses of the VALIDAR (VALIDation LIDAR) mobile lidar may include comparison with the data from an airborne Doppler wind lidar in preparation for validation by the airborne system of an earth orbiting Doppler wind lidar sensor.

  11. Results of the August 1977 Soviet and American meterological rocketsonde intercomparison held at Wallops Island, Virginia

    NASA Technical Reports Server (NTRS)

    Schmidlin, F. J.; Duke, J. R.; Ivanovsky, A. I.; Chernyshenko, Y. M.

    1980-01-01

    A coordinated program of rocketsonde investigations along about 60 deg E and 70 deg W between the United States and U.S.S.R. is discussed. The rocketsonde instruments used by the U.S. and U.S.S.R. were compared and the results are presented. The U.S. Super Loki Datasonde and the U.S.S.R. M100B rocketsonde are discussed. Results indicate that the U.S/U.S.S.R. rocketsonde measurement agreement improved since the 1973 intercomparisons. It was learned that the mean of the differences of the temperatures compare to within 6 C at about 60 km and to within 2 C near 50 km. Wind measurements were also found to agree.

  12. Urinary Biomarkers of Brain Diseases

    PubMed Central

    An, Manxia; Gao, Youhe

    2016-01-01

    Biomarkers are the measurable changes associated with a physiological or pathophysiological process. Unlike blood, urine is not subject to homeostatic mechanisms. Therefore, greater fluctuations could occur in urine than in blood, better reflecting the changes in human body. The roadmap of urine biomarker era was proposed. Although urine analysis has been attempted for clinical diagnosis, and urine has been monitored during the progression of many diseases, particularly urinary system diseases, whether urine can reflect brain disease status remains uncertain. As some biomarkers of brain diseases can be detected in the body fluids such as cerebrospinal fluid and blood, there is a possibility that urine also contain biomarkers of brain diseases. This review summarizes the clues of brain diseases reflected in the urine proteome and metabolome. PMID:26751805

  13. Immunization alters body odor.

    PubMed

    Kimball, Bruce A; Opiekun, Maryanne; Yamazaki, Kunio; Beauchamp, Gary K

    2014-04-10

    Infections have been shown to alter body odor. Because immune activation accompanies both infection and immunization, we tested the hypothesis that classical immunization might similarly result in the alteration of body odors detectable by trained biosensor mice. Using a Y-maze, we trained biosensor mice to distinguish between urine odors from rabies-vaccinated (RV) and unvaccinated control mice. RV-trained mice generalized this training to mice immunized with the equine West Nile virus (WNV) vaccine compared with urine of corresponding controls. These results suggest that there are similarities between body odors of mice immunized with these two vaccines. This conclusion was reinforced when mice could not be trained to directly discriminate between urine odors of RV- versus WNV-treated mice. Next, we trained biosensor mice to discriminate the urine odors of mice treated with lipopolysaccharide (LPS; a general elicitor of innate immunological responses) from the urine of control mice. These LPS-trained biosensors could distinguish between the odors of LPS-treated mouse urine and RV-treated mouse urine. Finally, biosensor mice trained to distinguish between the odors of RV-treated mouse urine and control mouse urine did not generalize this training to discriminate between the odors of LPS-treated mouse urine and control mouse urine. From these experiments, we conclude that: (1) immunization alters urine odor in similar ways for RV and WNV immunizations; and (2) immune activation with LPS also alters urine odor but in ways different from those of RV and WNV. Published by Elsevier Inc.

  14. To signal or not to signal? Chemical communication by urine-borne signals mirrors sexual conflict in crayfish

    PubMed Central

    2010-01-01

    Background Sexual selection theory predicts that females, being the limiting sex, invest less in courtship signals than males. However, when chemical signals are involved it is often the female that initiates mating by producing stimuli that inform about sex and/or receptivity. This apparent contradiction has been discussed in the literature as 'the female pheromone fallacy'. Because the release of chemical stimuli may not have evolved to elicit the male's courtship response, whether these female stimuli represent signals remains an open question. Using techniques to visualise and block release of urine, we studied the role of urine signals during fighting and mating interactions of crayfish (Pacifastacus leniusculus). Test individuals were blindfolded to exclude visual disturbance from dye release and artificial urine introduction. Results Staged female-male pairings during the reproductive season often resulted in male mating attempts. Blocking female urine release in such pairings prevented any male courtship behaviour. Artificial introduction of female urine re-established male mating attempts. Urine visualisation showed that female urine release coincides with aggressive behaviours but not with female submissive behaviour in reproductive interactions as well as in intersexual and intrasexual fights. In reproductive interactions, females predominately released urine during precopulatory aggression; males subsequently released significantly less urine during mating than in fights. Conclusions Urine-blocking experiments demonstrate that female urine contains sex-specific components that elicit male mating behaviour. The coincidence of chemical signalling and aggressive behaviour in both females and males suggests that urine release has evolved as an aggressive signal in both sexes of crayfish. By limiting urine release to aggressive behaviours in reproductive interactions females challenge their potential mating partners at the same time as they trigger a sexual response. These double messages should favour stronger males that are able to overcome the resistance of the female. We conclude that the difference between the sexes in disclosing urine-borne information reflects their conflicting interests in reproduction. Males discontinue aggressive urine signalling in order to increase their chances of mating. Females resume urine signalling in connection with aggressive behaviour, potentially repelling low quality or sexually inactive males while favouring reproduction with high quality males. PMID:20353555

  15. The method of urine sampling is not a valid predictor for vesicoureteral reflux in children after febrile urinary tract infections.

    PubMed

    Haid, Bernhard; Roesch, Judith; Strasser, Christa; Oswald, Josef

    2017-10-01

    The likelihood of detecting vesicoureteral reflux (VUR) after febrile urinary tract infections (UTI) in children logically should correlate with the correct diagnosis of the UTI. Beneath the unspecific symptoms of fever urine analysis is the main diagnostic criterion for the exact diagnosis of febrile UTIs in children. Use of inadequate urine sampling techniques during diagnosis may lead to impaired accuracy in UTI diagnosis. This could lead to the assumption that children, having diagnosed their UTI by the use of possibly inadequate urine sampling techniques should not be evaluated as consequently compared to those, where the diagnosis relied on sterile urine sampling techniques. We hypothesized that children with possibly contaminated urine samples during the initial diagnosis may show a lower rate of VUR in subsequent VCUGs because of a wrong diagnosis initially compared to children, where accurate urine sampling techniques were used. Between 2009 and 2014, a total of 555 patients underwent a primary VCUG at our department indicated because of febrile UTIs. Patients with urine collection methods other than bag urine and catheter/suprapubic aspiration (SPA) were excluded from this study (mid-stream urine, potty urine, n = 149). We evaluated 402 patients (male/female 131/271, mean age 1.91 years), VUR rates and grades were compared between patients where urine was sampled by the use of a urine bag only at the time of diagnosis (n = 296, 73.6%) and those where sterile urine sampling (catheter, suprapubic puncture) was performed (n = 106, 26.3%). 4 patients were excluded due to equivocal data on urine sampling. VUR rate in children after sterile urine sampling using a catheter or SPA accounted to 31.1%. In those where urine samples acquired by the use of urine bags were used, 33.7% showed VUR on subsequent VCUG (p = 0.718). There were no significant differences as to VUR grades or gender, although VUR was much more commonly diagnosed in female patients (37.0% vs 28.2%, p = 0.227) (Figure). Children diagnosed with their UTI by use of bag urine in our experience carried the same risk of showing a VUR in a subsequent VCUG compared to those, where the initial diagnosis relied - beneath clinical criteria - on urine samples acquired by suprapubic puncture or catheterization. Consequently urine-sampling technique during initial UTI diagnosis alone should not be used as predictor for the reliability of UTI diagnosis and should not influence the further management after UTI. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  16. Urinalysis and associated laboratory procedures.

    PubMed

    Brobst, D

    1989-09-01

    Macroscopic examination of urine is an integral part of urinalysis, and blood and bile pigments are a common cause of abnormal coloration. Urine SG is a convenient index of urine concentration and should be correlated with the patient's hydration status to determine the ability of the kidneys to concentrate and dilute urine. The pH of urine of dogs and cats normally is dietary dependent, but alkaline urine may suggest that the urinary tract is infected with a urea splitting organism. The dipstick test for proteinuria is convenient but less reliable than the sulfosalicylic acid method. The dipstick test for blood should not be used as a substitute for microscopic examination of urine but is of value in detecting hemoglobinuria and myoglobinuria, when red cells may be absent in the sediment. The finding of glucose, ketones, and bilirubin in urine, when interpreted properly, may indicate the presence of disease processes not associated with the urogenital tract. Microscopic examination of urine sediment must be interpreted in combination with the physical and chemical composition of urine, but excessive numbers of cells, casts, crystals, and bacteria may provide evidence of disease. The absence of these structures in the sediment, however, does not eliminate the possibility of disease. The ability of the kidneys to concentrate urine is dependent on normal kidney function and the production and release of ADH. A urine SG greater than 1.030 in dogs and 1.035 in cats indicates that the functions associated with concentrating urine are adequate. In the evaluation of the patient's ability to form concentrated urine, the status of hydration must be considered; this may require water deprivation tests or administration of ADH. The estimation of blood urea nitrogen concentration, with the use of test strips, may provide a convenient but not specific measure of renal function.

  17. Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?

    PubMed Central

    Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok

    2012-01-01

    Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881

  18. Inflammatory and fibrotic proteins proteomically identified as key protein constituents in urine and stone matrix of patients with kidney calculi.

    PubMed

    Boonla, Chanchai; Tosukhowong, Piyaratana; Spittau, Björn; Schlosser, Andreas; Pimratana, Chaowat; Krieglstein, Kerstin

    2014-02-15

    To uncover whether urinary proteins are incorporated into stones, the proteomic profiles of kidney stones and urine collected from the same patients have to be explored. We employed 1D-PAGE and nanoHPLC-ESI-MS/MS to analyze the proteomes of kidney stone matrix (n=16), nephrolithiatic urine (n=14) and healthy urine (n=3). We identified 62, 66 and 22 proteins in stone matrix, nephrolithiatic urine and healthy urine, respectively. Inflammation- and fibrosis-associated proteins were frequently detected in the stone matrix and nephrolithiatic urine. Eighteen proteins were exclusively found in the stone matrix and nephrolithiatic urine, considered as candidate biomarkers for kidney stone formation. S100A8 and fibronectin, representatives of inflammation and fibrosis, respectively, were up-regulated in nephrolithiasis renal tissues. S100A8 was strongly expressed in infiltrated leukocytes. Fibronectin was over-expressed in renal tubular cells. S100A8 and fibronectin were immunologically confirmed to exist in nephrolithiatic urine and stone matrix, but in healthy urine they were undetectable. Conclusion, both kidney stones and urine obtained from the same patients greatly contained inflammatory and fibrotic proteins. S100A8 and fibronectin were up-regulated in stone-baring kidneys and nephrolithiatic urine. Therefore, inflammation and fibrosis are suggested to be involved in the formation of kidney calculi. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Urine drainage bags

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000142.htm Urine drainage bags To use the sharing features on this page, please enable JavaScript. Urine drainage bags collect urine. Your bag will attach ...

  20. Urine - abnormal color

    MedlinePlus

    ... medlineplus.gov/ency/article/003139.htm Urine - abnormal color To use the sharing features on this page, please enable JavaScript. The usual color of urine is straw-yellow. Abnormally colored urine ...

  1. Urine output - decreased

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003147.htm Urine output - decreased To use the sharing features on this page, please enable JavaScript. Decreased urine output means that you produce less urine than ...

  2. Urine Color

    MedlinePlus

    ... during urinary tract infections caused by pseudomonas bacteria. Dark brown or cola-colored urine Brown urine can ... of fava beans, rhubarb or aloe can cause dark brown urine. Medications. A number of drugs can ...

  3. Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.

    PubMed

    Broeren, Maarten A C; Bahçeci, Semiha; Vader, Huib L; Arents, Niek L A

    2011-03-01

    The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated the detection of bacteria and leukocytes by a new urine analyzer, the UF-1000i, to identify negative urine samples that can be excluded from urine culture. In total, 1,577 urine samples were analyzed and compared to urine culture. Urine culture showed growth of ≥10(3) CFU/ml in 939 samples (60%). Receiver operating characteristics (ROC) curves and ROC decision plots were been prepared at three different gold standard definitions of a negative urine culture: no growth, growth of bacteria at <10(4) CFU/ml, and growth of bacteria at <10(5) CFU/ml. Also, the reduction in urine cultures and the percentage of false negatives were calculated. At the most stringent gold standard definition of no growth, a chosen sensitivity of 95% resulted in a cutoff value of 26 bacteria/μl, a specificity of 43% and a reduction in urine cultures of only 20%, of which 14% were false negatives. However, at a gold standard definition of <10(5) CFU/ml and a sensitivity of 95%, the UF-1000i cutoff value was 230 bacteria/μl, the specificity was 80%, and the reduction in urine cultures was 52%, of which 0.3% were false negatives. The applicability of the UF-1000i to screen for negative urine samples strongly depends on population characteristics and the definition of a negative urine culture. In our setting, however, the low workload savings and the high percentage of false-negative results do not warrant the UF-1000i to be used as a screening analyzer.

  4. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    PubMed

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  5. Lack of clinical utility of urine gram stain for suspected urinary tract infection in pediatric patients.

    PubMed

    Cantey, Joseph B; Gaviria-Agudelo, Claudia; McElvania TeKippe, Erin; Doern, Christopher D

    2015-04-01

    Urinary tract infection (UTI) is one of the most common infections in children. Urine culture remains the gold standard for diagnosis, but the utility of urine Gram stain relative to urinalysis (UA) is unclear. We reviewed 312 pediatric patients with suspected UTI who had urine culture, UA, and urine Gram stain performed from a single urine specimen. UA was considered positive if ≥10 leukocytes per oil immersion field were seen or if either nitrates or leukocyte esterase testing was positive. Urine Gram stain was considered positive if any organisms were seen. Sensitivity, specificity, and positive and negative predictive values were calculated using urine culture as the gold standard. Thirty-seven (12%) patients had a culture-proven UTI. Compared to urine Gram stain, UA had equal sensitivity (97.3% versus 97.5%) and higher specificity (85% versus 74%). Empirical therapy was prescribed before the Gram stain result was known in 40 (49%) patients and after in 42 (51%) patients. The antibiotics chosen did not differ between the two groups (P=0.81), nor did they differ for patients with Gram-negative rods on urine Gram stain compared to those with Gram-positive cocci (P=0.67). From these data, we conclude that UA has excellent negative predictive value that is not enhanced by urine Gram stain and that antibiotic selection did not vary based on the urine Gram stain result. In conclusion, the clinical utility of urine Gram stain does not warrant the time or cost it requires. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  6. Lack of Clinical Utility of Urine Gram Stain for Suspected Urinary Tract Infection in Pediatric Patients

    PubMed Central

    Gaviria-Agudelo, Claudia; McElvania TeKippe, Erin; Doern, Christopher D.

    2015-01-01

    Urinary tract infection (UTI) is one of the most common infections in children. Urine culture remains the gold standard for diagnosis, but the utility of urine Gram stain relative to urinalysis (UA) is unclear. We reviewed 312 pediatric patients with suspected UTI who had urine culture, UA, and urine Gram stain performed from a single urine specimen. UA was considered positive if ≥10 leukocytes per oil immersion field were seen or if either nitrates or leukocyte esterase testing was positive. Urine Gram stain was considered positive if any organisms were seen. Sensitivity, specificity, and positive and negative predictive values were calculated using urine culture as the gold standard. Thirty-seven (12%) patients had a culture-proven UTI. Compared to urine Gram stain, UA had equal sensitivity (97.3% versus 97.5%) and higher specificity (85% versus 74%). Empirical therapy was prescribed before the Gram stain result was known in 40 (49%) patients and after in 42 (51%) patients. The antibiotics chosen did not differ between the two groups (P = 0.81), nor did they differ for patients with Gram-negative rods on urine Gram stain compared to those with Gram-positive cocci (P = 0.67). From these data, we conclude that UA has excellent negative predictive value that is not enhanced by urine Gram stain and that antibiotic selection did not vary based on the urine Gram stain result. In conclusion, the clinical utility of urine Gram stain does not warrant the time or cost it requires. PMID:25653411

  7. Filter paper saturated by urine sample in metabolic disorders detection by proton magnetic resonance spectroscopy.

    PubMed

    Blasco, Hélène; Garrigue, Marie-Ange; De Vos, Aymeric; Antar, Catherine; Labarthe, François; Maillot, François; Andres, Christian R; Nadal-Desbarats, Lydie

    2010-02-01

    NMR spectroscopy of urine samples is able to diagnose many inborn errors of metabolism (IEM). However, urinary metabolites have a poor stability, requiring special care for routine analysis (storage of urine at -20 or -80 degrees C, fast transport). The aim of our study was to investigate the reliability of dried urine filter paper for urine storage and transport and to evaluate the ability of NMR to detect several IEM using this method. Urine samples from five healthy subjects were analyzed by (1)H NMR following different storage conditions (-20 vs 4 degrees C vs dried on filter paper) and at different time points (24 h, 48 h, 96 h, and 7 days). Urine pattern of fresh urine was considered as a reference. We analyzed the conservation of some amino acids and organic acids using Bland and Altman plot with intraclass correlation coefficient determination. Then, we evaluated the use of filter paper to detect four different IEM (methylmalonic and isovaleric acidurias, ornithine transcarbamylase deficiency, and cystinuria). Analysis of urine samples from healthy subjects revealed a high stability of studied molecules (ICC > 0.8) even after 7 days of storage on filter paper. Moreover, an excellent preservation of metabolites specifically accumulated in IEM was observed when analysis of dried urine filter paper was compared to fresh urine (coefficient of variation < 15%). This preliminary study demonstrates that storage of dried urine on filter paper is reliable for (1)H NMR spectroscopy analysis. Preservation of urine molecules over time using that method is convenient for routine clinical practice.

  8. Basic or extended urine sampling to analyse urine production?

    PubMed

    Denys, Marie-Astrid; Kapila, Vansh; Weiss, Jeffrey; Goessaert, An-Sofie; Everaert, Karel

    2017-09-01

    Frequency volume charts are valuable tools to objectify urine production in patients with nocturia, enuresis or nocturnal incontinence. Analyses of daytime and nighttime urine (=basic collection) or analyses of urine samples collected every 3 h (=extended collection) extend this evaluation by describing circadian patterns of water and solute diuresis (=renal function profiles). To assess intra-individual correlation and agreement between renal function profiles provided using basic and extended urine collections, and using two extended urine collections. To create a short-form of the extended collection. This prospective observational study was executed at Ghent University Hospital, Belgium. Study participation was open for anyone visiting the hospital. Participants collected one basic and two extended 24-h urine collections. Urinary levels of osmolality, sodium and creatinine were determined. There was a moderate to strong correlation between results of basic and extended urinalyses. Comparing both extended urinalyses showed a moderate correlation between the eight individual samples and a weak to strong correlation between the mean daytime and nighttime values of renal functions. Different samples could be considered as most representative for mean daytime values, while all samples collected between 03 and 05am showed the highest agreement with mean nighttime values of renal function. Since there is a good correlation and agreement between basic and extended urine collections to study the mechanisms underlying urine production, the choice of urine sampling method to evaluate urine production depends on the purpose. A nighttime-only urine sample collected between 03 and 05am may be the most practical approach. © 2017 Wiley Periodicals, Inc.

  9. An exploratory study on seawater-catalysed urine phosphorus recovery (SUPR).

    PubMed

    Dai, Ji; Tang, Wen-Tao; Zheng, Yi-Se; Mackey, Hamish R; Chui, Ho Kwong; van Loosdrecht, Mark C M; Chen, Guang-Hao

    2014-12-01

    Phosphorus (P) is a crucial and non-renewable resource, while it is excessively discharged via sewage, significant amounts originating from human urine. Recovery of P from source-separated urine presents an opportunity not only to recover this precious resource but also to improve downstream sewage treatment works. This paper proposes a simple and economic method to recover urine derived P by using seawater as a low-cost precipitant to form struvite, as Hong Kong has practised seawater toilet flushing as an alternative water resource since 1958. Chemical reactions, process conditions and precipitate composition for P precipitation in urine have been investigated to develop this new urine P recovery approach. This study concluded that ureolysis extent in a urine-seawater mixture determines the reaction pH that in turn influences the P recovery efficiency significantly; 98% of urine P can precipitate with seawater within 10 min when 40-75% of the urea in urine is ureolysed; the urine to seawater ratio alters the composition of the precipitates. The P content in the precipitates was found to be more than 9% when the urine fraction was 40% or higher. Magnesium ammonium phosphate (MAP) was confirmed to be the predominant component of the precipitates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Alterations of microbiota in urine from women with interstitial cystitis

    PubMed Central

    2012-01-01

    Background Interstitial Cystitis (IC) is a chronic inflammatory condition of the bladder with unknown etiology. The aim of this study was to characterize the microbial community present in the urine from IC female patients by 454 high throughput sequencing of the 16S variable regions V1V2 and V6. The taxonomical composition, richness and diversity of the IC microbiota were determined and compared to the microbial profile of asymptomatic healthy female (HF) urine. Results The composition and distribution of bacterial sequences differed between the urine microbiota of IC patients and HFs. Reduced sequence richness and diversity were found in IC patient urine, and a significant difference in the community structure of IC urine in relation to HF urine was observed. More than 90% of the IC sequence reads were identified as belonging to the bacterial genus Lactobacillus, a marked increase compared to 60% in HF urine. Conclusion The 16S rDNA sequence data demonstrates a shift in the composition of the bacterial community in IC urine. The reduced microbial diversity and richness is accompanied by a higher abundance of the bacterial genus Lactobacillus, compared to HF urine. This study demonstrates that high throughput sequencing analysis of urine microbiota in IC patients is a powerful tool towards a better understanding of this enigmatic disease. PMID:22974186

  11. Cleaved Form of Osteopontin in Urine as a Clinical Marker of Lupus Nephritis

    PubMed Central

    Kitagori, Koji; Yoshifuji, Hajime; Oku, Takuma; Sasaki, Chiyomi; Miyata, Hitomi; Mori, Keita P.; Nakajima, Toshiki; Ohmura, Koichiro; Kawabata, Daisuke; Yukawa, Naoichiro; Imura, Yoshitaka; Murakami, Kosaku; Nakashima, Ran; Usui, Takashi; Fujii, Takao; Sakai, Kaoru; Yanagita, Motoko; Hirayama, Yoshitaka; Mimori, Tsuneyo

    2016-01-01

    We assessed the utility of two forms of osteopontin (OPN), OPN full and its cleaved form (OPN N-half), in plasma and urine as markers of disease activity in lupus nephritis (LN). Samples were collected from patients with systemic lupus erythematosus (SLE) (LN: N = 29, non-LN: N = 27), IgA nephropathy (IgAN) (N = 14), minimal change nephrotic syndrome (MCNS) (N = 5), diabetic nephropathy (DN) (N = 14) and healthy volunteers (HC) (N = 17). While there was no significant difference in urine OPN full concentration between groups, urine OPN N-half concentration was significantly higher in patients with LN than HC (p < 0.05). Moreover, urine OPN N-half was higher in LN patients with overt proteinuria (urine protein/creatinine ratio: P/C > 0.5) than LN patients with minimal proteinuria (P/C < 0.5, p < 0.0001), and also higher than in DN patients with overt proteinuria (P/C > 0.5, p < 0.01). Urine thrombin activity correlated with urine OPN N-half concentration (p < 0.0001), but not with urine OPN full concentration. These results suggest that urine OPN N-half concentration reflects renal inflammation. Thus, urine OPN N-half may be a novel disease activity marker for LN. PMID:27992535

  12. Osmolality urine test

    MedlinePlus

    ... balance and urine concentration. Osmolality is a more exact measurement of urine concentration than the urine specific ... must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get ...

  13. Glucose urine test

    MedlinePlus

    Urine sugar test; Urine glucose test; Glucosuria test; Glycosuria test ... After you provide a urine sample, it is tested right away. The health care provider uses a dipstick made with a color-sensitive pad. The ...

  14. 24-hour urinary aldosterone excretion test

    MedlinePlus

    Aldosterone - urine; Addison disease - urine aldosterone; Cirrhosis - serum aldosterone ... A 24-hour urine sample is needed. You will need to collect your urine over 24 hours . Your health care provider will tell ...

  15. Multicentre validation of IMRT pre-treatment verification: comparison of in-house and external audit.

    PubMed

    Jornet, Núria; Carrasco, Pablo; Beltrán, Mercè; Calvo, Juan Francisco; Escudé, Lluís; Hernández, Victor; Quera, Jaume; Sáez, Jordi

    2014-09-01

    We performed a multicentre intercomparison of IMRT optimisation and dose planning and IMRT pre-treatment verification methods and results. The aims were to check consistency between dose plans and to validate whether in-house pre-treatment verification results agreed with those of an external audit. Participating centres used two mock cases (prostate and head and neck) for the intercomparison and audit. Compliance to dosimetric goals and total number of MU per plan were collected. A simple quality index to compare the different plans was proposed. We compared gamma index pass rates using the centre's equipment and methodology to those of an external audit. While for the prostate case, all centres fulfilled the dosimetric goals and plan quality was homogeneous, that was not the case for the head and neck case. The number of MU did not correlate with the plan quality index. Pre-treatment verifications results of the external audit did not agree with those of the in-house measurements for two centres: being within tolerance for in-house measurements and unacceptable for the audit or the other way round. Although all plans fulfilled dosimetric constraints, plan quality is highly dependent on the planner expertise. External audits are an excellent tool to detect errors in IMRT implementation and cannot be replaced by intercomparison using results obtained by centres. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Introduction to the SPARC Reanalysis Intercomparison Project (S-RIP) and overview of the reanalysis systems

    NASA Astrophysics Data System (ADS)

    Fujiwara, Masatomo; Wright, Jonathon S.; Manney, Gloria L.; Gray, Lesley J.; Anstey, James; Birner, Thomas; Davis, Sean; Gerber, Edwin P.; Harvey, V. Lynn; Hegglin, Michaela I.; Homeyer, Cameron R.; Knox, John A.; Krüger, Kirstin; Lambert, Alyn; Long, Craig S.; Martineau, Patrick; Molod, Andrea; Monge-Sanz, Beatriz M.; Santee, Michelle L.; Tegtmeier, Susann; Chabrillat, Simon; Tan, David G. H.; Jackson, David R.; Polavarapu, Saroja; Compo, Gilbert P.; Dragani, Rossana; Ebisuzaki, Wesley; Harada, Yayoi; Kobayashi, Chiaki; McCarty, Will; Onogi, Kazutoshi; Pawson, Steven; Simmons, Adrian; Wargan, Krzysztof; Whitaker, Jeffrey S.; Zou, Cheng-Zhi

    2017-01-01

    The climate research community uses atmospheric reanalysis data sets to understand a wide range of processes and variability in the atmosphere, yet different reanalyses may give very different results for the same diagnostics. The Stratosphere-troposphere Processes And their Role in Climate (SPARC) Reanalysis Intercomparison Project (S-RIP) is a coordinated activity to compare reanalysis data sets using a variety of key diagnostics. The objectives of this project are to identify differences among reanalyses and understand their underlying causes, to provide guidance on appropriate usage of various reanalysis products in scientific studies, particularly those of relevance to SPARC, and to contribute to future improvements in the reanalysis products by establishing collaborative links between reanalysis centres and data users. The project focuses predominantly on differences among reanalyses, although studies that include operational analyses and studies comparing reanalyses with observations are also included when appropriate. The emphasis is on diagnostics of the upper troposphere, stratosphere, and lower mesosphere. This paper summarizes the motivation and goals of the S-RIP activity and extensively reviews key technical aspects of the reanalysis data sets that are the focus of this activity. The special issue The SPARC Reanalysis Intercomparison Project (S-RIP) in this journal serves to collect research with relevance to the S-RIP in preparation for the publication of the planned two (interim and full) S-RIP reports.

  17. The CMIP6 Sea-Ice Model Intercomparison Project (SIMIP): Understanding sea ice through climate-model simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Notz, Dirk; Jahn, Alexandra; Holland, Marika

    A better understanding of the role of sea ice for the changing climate of our planet is the central aim of the diagnostic Coupled Model Intercomparison Project 6 (CMIP6)-endorsed Sea-Ice Model Intercomparison Project (SIMIP). To reach this aim, SIMIP requests sea-ice-related variables from climate-model simulations that allow for a better understanding and, ultimately, improvement of biases and errors in sea-ice simulations with large-scale climate models. This then allows us to better understand to what degree CMIP6 model simulations relate to reality, thus improving our confidence in answering sea-ice-related questions based on these simulations. Furthermore, the SIMIP protocol provides a standardmore » for sea-ice model output that will streamline and hence simplify the analysis of the simulated sea-ice evolution in research projects independent of CMIP. To reach its aims, SIMIP provides a structured list of model output that allows for an examination of the three main budgets that govern the evolution of sea ice, namely the heat budget, the momentum budget, and the mass budget. Furthermore, we explain the aims of SIMIP in more detail and outline how its design allows us to answer some of the most pressing questions that sea ice still poses to the international climate-research community.« less

  18. The CMIP6 Sea-Ice Model Intercomparison Project (SIMIP): Understanding sea ice through climate-model simulations

    DOE PAGES

    Notz, Dirk; Jahn, Alexandra; Holland, Marika; ...

    2016-09-23

    A better understanding of the role of sea ice for the changing climate of our planet is the central aim of the diagnostic Coupled Model Intercomparison Project 6 (CMIP6)-endorsed Sea-Ice Model Intercomparison Project (SIMIP). To reach this aim, SIMIP requests sea-ice-related variables from climate-model simulations that allow for a better understanding and, ultimately, improvement of biases and errors in sea-ice simulations with large-scale climate models. This then allows us to better understand to what degree CMIP6 model simulations relate to reality, thus improving our confidence in answering sea-ice-related questions based on these simulations. Furthermore, the SIMIP protocol provides a standardmore » for sea-ice model output that will streamline and hence simplify the analysis of the simulated sea-ice evolution in research projects independent of CMIP. To reach its aims, SIMIP provides a structured list of model output that allows for an examination of the three main budgets that govern the evolution of sea ice, namely the heat budget, the momentum budget, and the mass budget. Furthermore, we explain the aims of SIMIP in more detail and outline how its design allows us to answer some of the most pressing questions that sea ice still poses to the international climate-research community.« less

  19. Ice nucleating particles measured during the laboratory and field intercomparisons FIN-2 and FIN-3 by the diffusion chamber FRIDGE

    NASA Astrophysics Data System (ADS)

    Weber, Daniel; Schrod, Jann; Curtius, Joachim; Haunold, Werner; Thomson, Erik; Bingemer, Heinz

    2016-04-01

    The measurement of atmospheric ice nucleating particles (INP) is still challenging. In the absence of easily applicable INP standards the intercomparison of different methods during collaborative laboratory and field workshops is a valuable tool that can shine light on the performance of individual methods for the measurement of INP [1]. FIN-2 was conducted in March 2015 at the AIDA facility in Karlsruhe as an intercomparison of mobile instruments for measuring INP [2]. FIN-3 was a field campaign at the Desert Research Institutes Storm Peak Laboratory in Colorado in September 2015 [3]. The FRankfurt Ice nucleation Deposition freezinG Experiment (FRIDGE) participated in both experiments. FRIDGE measures ice nucleating particles by electrostatic precipitation of aerosol particles onto Si-wafers in a collection unit, followed by activation, growth, and optical detection of ice crystals on the substrate in an isostatic diffusion chamber [4,5]. We will present and discuss results of our measurements of deposition/condensation INP and of immersion INP with FRIDGE during FIN-2 and FIN-3. Acknowledgements: The valuable contributions of the FIN organizers and their institutions, and of the FIN Workshop Science team are gratefully acknowledged. Our work was supported by Deutsche Forschungsgemeinschaft (DFG) under the Research Unit FOR 1525 (INUIT) and the EU FP7-ENV- 2013 BACCHUS project under Grant Agreement 603445.

  20. The 1995 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers

    PubMed Central

    Early, Edward; Thompson, Ambler; Johnson, Carol; DeLuisi, John; Disterhoft, Patrick; Wardle, David; Wu, Edmund; Mou, Wanfeng; Sun, Yongchen; Lucas, Timothy; Mestechkina, Tanya; Harrison, Lee; Berndt, Jerry; Hayes, Douglas S.

    1998-01-01

    Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, the second North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held June 12 to 23, 1995 at Table Mountain outside Boulder, Colorado, USA. This Intercomparison was coordinated by the National Institute of Standards and Technology (NIST) and the National Oceanic and Atmospheric Administration (NOAA). Participating agencies were the Environmental Protection Agency; the National Science Foundation; the Smithsonian Environmental Research Center; the Department of Agriculture; and the Atmospheric Environment Service, Canada. Instruments were characterized for wavelength uncertainty, bandwidth, stray-light rejection, and spectral irradiance responsivity, the latter with a NIST standard lamp operating in a specially designed field calibration unit. The spectral irradiance responsivity, determined once indoors and twice outdoors, demonstrated that while the responsivities changed upon moving the instruments, they were relatively stable when the instruments remained outdoors. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST standard lamp and three different convolution functions to account for the different bandwidths of the instruments, the measured solar irradiances generally agreed to within 3 %. PMID:28009371

  1. The Model Intercomparison Project on the Climatic Response to Volcanic Forcing (VolMIP): Experimental Design and Forcing Input Data for CMIP6

    NASA Technical Reports Server (NTRS)

    Zanchettin, Davide; Khodri, Myriam; Timmreck, Claudia; Toohey, Matthew; Schmidt, Anja; Gerber, Edwin P.; Hegerl, Gabriele; Robock, Alan; Pausata, Francesco; Ball, William T.; hide

    2016-01-01

    The enhancement of the stratospheric aerosol layer by volcanic eruptions induces a complex set of responses causing global and regional climate effects on a broad range of timescales. Uncertainties exist regarding the climatic response to strong volcanic forcing identified in coupled climate simulations that contributed to the fifth phase of the Coupled Model Intercomparison Project (CMIP5). In order to better understand the sources of these model diversities, the Model Intercomparison Project on the climatic response to Volcanic forcing (VolMIP) has defined a coordinated set of idealized volcanic perturbation experiments to be carried out in alignment with the CMIP6 protocol. VolMIP provides a common stratospheric aerosol data set for each experiment to minimize differences in the applied volcanic forcing. It defines a set of initial conditions to assess how internal climate variability contributes to determining the response. VolMIP will assess to what extent volcanically forced responses of the coupled ocean-atmosphere system are robustly simulated by state-of-the-art coupled climate models and identify the causes that limit robust simulated behavior, especially differences in the treatment of physical processes. This paper illustrates the design of the idealized volcanic perturbation experiments in the VolMIP protocol and describes the common aerosol forcing input data sets to be used.

  2. [Implementation of quality standard UNE-EN ISO/IEC 17043 in the External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology].

    PubMed

    Poveda Gabaldón, Marta; Ovies, María Rosario; Orta Mira, Nieves; Serrano, M del Remedio Guna; Avila, Javier; Giménez, Alicia; Cardona, Concepción Gimeno

    2011-12-01

    The quality standard "UNE-EN-ISO 17043: 2010. Conformity assessment. General requirements for proficiency testing" applies to centers that organize intercomparisons in all areas. In the case of clinical microbiology laboratories, these intercomparisons must meet the management and technical standards required to achieve maximum quality in the performance of microbiological analysis and the preparation of test items (sample, product, data or other information used in the proficiency test) to enable them to be accredited. Once accredited, these laboratories can operate as a tool for quality control laboratories and competency assessment. In Spain, accreditation is granted by the Spanish Accreditation Body [Entidad Nacional de Acreditación (ENAC)]. The objective of this review is to explain how to apply the requirements of the standard to laboratories providing intercomparisons in the field of clinical microbiology (the organization responsible for all the tasks related to the development and operation of a proficiency testing program). This requires defining the scope and specifying the technical requirements (personnel management, control of equipment, facilities and environment, the design of the proficiency testing and data analysis for performance evaluation, communication with participants and confidentiality) and management requirements (document control, purchasing control, monitoring of complaints / claims, non-compliance, internal audits and management reviews). Copyright © 2011 Elsevier España S.L. All rights reserved.

  3. The Joint Experiment for Crop Assessment and Monitoring (JECAM): Synthetic Aperture Radar (SAR) Inter-Comparison Experiment

    NASA Astrophysics Data System (ADS)

    Dingle Robertson, L.; Hosseini, M.; Davidson, A. M.; McNairn, H.

    2017-12-01

    The Joint Experiment for Crop Assessment and Monitoring (JECAM) is the research and development branch of GEOGLAM (Group on Earth Observations Global Agricultural Monitoring), a G20 initiative to improve the global monitoring of agriculture through the use of Earth Observation (EO) data and remote sensing. JECAM partners represent a diverse network of researchers collaborating towards a set of best practices and recommendations for global agricultural analysis using EO data, with well monitored test sites covering a wide range of agriculture types, cropping systems and climate regimes. Synthetic Aperture Radar (SAR) for crop inventory and condition monitoring offers many advantages particularly the ability to collect data under cloudy conditions. The JECAM SAR Inter-Comparison Experiment is a multi-year, multi-partner project that aims to compare global methods for (1) operational SAR & optical; multi-frequency SAR; and compact polarimetry methods for crop monitoring and inventory, and (2) the retrieval of Leaf Area Index (LAI) and biomass estimations using models such as the Water Cloud Model (WCM) employing single frequency SAR; multi-frequency SAR; and compact polarimetry. The results from these activities will be discussed along with an examination of the requirements of a global experiment including best-date determination for SAR data acquisition, pre-processing techniques, in situ data sharing, model development and statistical inter-comparison of the results.

  4. Intercomparison of global, ultraviolet B and A radiation measurements in the Dead Sea region (Ein Bokek) and Beer Sheva.

    PubMed

    Kushelevsky, A P; Kudish, A I

    1996-07-01

    Thousands of patients suffering from psoriasis have been treated successfully in the Dead Sea area by climatological methods, without medication. This high rate of success, measured in terms of partial to complete plaque clearance and reported to exceed 85% after 3-4 weeks of treatment, has been assumed to be associated with a unique ultraviolet (UV) radiation environment present in the Dead Sea region. In order to broaden our knowledge of the UV radiation environment at the Dead Sea, continuous monitoring of UV (both B and A) and global radiation has recently been initiated at two sites--Ein Bokek (located in the vicinity of the Dead Sea 375 m below mean sea level) and Beer Sheva (315 m above mean sea level)--to facilitate an intercomparison of their respective radiation intensities. The results of the first year of a detailed study of the global, UVB and UVA radiation intensities measured at both sites are summarized and reported in terms of the monthly average daily, average midday (11:00-13:00) and the corresponding maximum values. The radiation data for clear days (based upon the absolute magnitude of the global radiation) were also analyzed to perform an intercomparison between Ein Bokek and Beer Sheva for a winter month and a summer month for which all three types of radiation data were available at both sites.

  5. Bilateral Comparison of Mercury and Gallium Fixed-Point Cells Using Standard Platinum Resistance Thermometer

    NASA Astrophysics Data System (ADS)

    Bojkovski, J.; Veliki, T.; Zvizdić, D.; Drnovšek, J.

    2011-08-01

    The objective of project EURAMET 1127 (Bilateral comparison of triple point of mercury and melting point of gallium) in the field of thermometry is to compare realization of a triple point of mercury (-38.8344 °C) and melting point of gallium (29.7646 °C) between the Slovenian national laboratory MIRS/UL-FE/LMK and the Croatian national laboratory HMI/FSB-LPM using a long-stem 25 Ω standard platinum resistance thermometer (SPRT). MIRS/UL/FE-LMK participated in a number of intercomparisons on the level of EURAMET. On the other hand, the HMI/LPM-FSB laboratory recently acquired new fixed-point cells which had to be evaluated in the process of intercomparisons. A quartz-sheathed SPRT has been selected and calibrated at HMI/LPM-FSB at the triple point of mercury, the melting point of gallium, and the water triple point. A second set of measurements was made at MIRS/UL/FE-LMK. After its return, the SPRT was again recalibrated at HMI/LPM-FSB. In the comparison, the W value of the SPRT has been used. Results of the bilateral intercomparison confirmed that the new gallium cell of the HMI/LPM-FSB has a value that is within uncertainty limits of both laboratories that participated in the exercise, while the mercury cell experienced problems. After further research, a small leakage in the mercury fixed-point cell has been found.

  6. International Intercomparison of Specific Absorption Rates in a Flat Absorbing Phantom in the Near-Field of Dipole Antennas

    PubMed Central

    Davis, Christopher C.; Beard, Brian B.; Tillman, Ahlia; Rzasa, John; Merideth, Eric; Balzano, Quirino

    2018-01-01

    This paper reports the results of an international intercomparison of the specific absorption rates (SARs) measured in a flat-bottomed container (flat phantom), filled with human head tissue simulant fluid, placed in the near-field of custom-built dipole antennas operating at 900 and 1800 MHz, respectively. These tests of the reliability of experimental SAR measurements have been conducted as part of a verification of the ways in which wireless phones are tested and certified for compliance with safety standards. The measurements are made using small electric-field probes scanned in the simulant fluid in the phantom to record the spatial SAR distribution. The intercomparison involved a standard flat phantom, antennas, power meters, and RF components being circulated among 15 different governmental and industrial laboratories. At the conclusion of each laboratory’s measurements, the following results were communicated to the coordinators: Spatial SAR scans at 900 and 1800 MHz and 1 and 10 g maximum spatial SAR averages for cubic volumes at 900 and 1800 MHz. The overall results, given as meanstandard deviation, are the following: at 900 MHz, 1 g average 7.850.76; 10 g average 5.160.45; at 1800 MHz, 1 g average 18.44 ± 1.65; 10 g average 10.14 ± 0.85, all measured in units of watt per kilogram, per watt of radiated power. PMID:29520117

  7. Enlarged prostate

    MedlinePlus

    ... gland. Other tests may include: Urine flow rate Post-void residual urine test to see how much urine is left in your bladder after you urinate Pressure-flow studies to measure the pressure in the bladder as ...

  8. Length of time domestic dogs (Canis familiaris) spend smelling urine of gonadectomised and intact conspecifics.

    PubMed

    Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D

    2017-09-01

    Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S; Brian Culligan, B

    2007-08-28

    The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides andmore » strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.« less

  10. The Impact of Using Different Methods to Assess Completeness of 24-Hour Urine Collection on Estimating Dietary Sodium.

    PubMed

    Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard

    2016-06-01

    The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted. ©2015 Wiley Periodicals, Inc.

  11. Effects of diet composition on mutagenic activity in urine.

    PubMed

    Ohara, Akihiro; Matsuhisa, Tsugio

    2004-01-01

    The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.

  12. [Is bacteriological testing of bladder urine informative in acute obstructive pyelo- nephritis?

    PubMed

    Kogan, M I; Naboka, Yu L; Bedzhanyan, S K; Mitusova, E V; Gudima, I A; Morgun, P P; Vasileva, L I

    2017-07-01

    The problem of the etiology and pathogenesis of acute obstructive pyelonephritis (OOP) remains one of the challenging issues of modern urology. Etiological agents of pyelonephritis can be both gram-negative and gram-positive opportunistic bacteria mostly belonging to the normal flora in humans. The generally accepted diagnostic work-up involves a bacteriological testing of not pelvic urine, but of bladder urine collected by a transurethral catheter or midstream specimens of urine collected from the patients. The aim of our study was to compare the microbiota of bladder and pelvic urine in patients with OOP. The study comprised 72 sequentially selected patients (12 men and 60 women) with OOP associated with ureteral stones. Mean age of patients was 53.7+/-0.5 years. All patients underwent bacteriological examination of the bladder urine collected by a transurethral catheter and pelvic urine obtained after relieving stone-related ureteral obstruction. Urinary diversion was performed using j-j stent and PCN in 64 and 8 patients, respectively. Preoperative prophylactic antibiotics were administered routinely. Bacteriological testing of urine was carried out using an extended set (9-10) of culture media. Empirical antibiotic therapy was initiated only after the restoration of urine outflow from the kidney and continued for 5-6 days until the availability of bacteriological testing results. Levels of bacteriuria with Enterobacteria, gram-positive pathogens and NAB in two urine samples did not differ significantly (p>0.05). There was a wide range of bacteriuria from 101 to 106 CFU/ml of most microorganisms except @Proteus spp., S. aureus. In bladder urine, the rates of bacteriuria of more or equal 104 CFU/ml for E. coli, Klebsiella spp. and Proteus spp. were 90.9%, 72.7% and 100.0%, respectively. For the remaining microorganisms, predominant bacteriuria was less or equal 103 CFU/ml. In pelvic urine, the rates of bacteriuria of more or equal 104 CFU/ml for E. coli, Klebsiella spp. and Proteus spp. was 71.8%, 40.0% and 66.7%, respectively. Other uropathogens in the pelvic urine mainly had a bacterial count of less or equal 103 CFU/ml. Only the concentration of Corynebacterium spp. in the pelvic urine significantly (p=0.023) differed from that of the bladder urine. There were no significant differences between microbiota of bladder and pelvic urine depending on duration of OOP except higher rates of Corynebacterium spp. in the bladder urine.

  13. Urine and Urination

    MedlinePlus

    Your kidneys make urine by filtering wastes and extra water from your blood. The waste is called urea. Your blood carries it to the kidneys. From the kidneys, urine travels down two thin tubes called ureters to ...

  14. Urinary Biomarkers of Brain Diseases.

    PubMed

    An, Manxia; Gao, Youhe

    2015-12-01

    Biomarkers are the measurable changes associated with a physiological or pathophysiological process. Unlike blood, urine is not subject to homeostatic mechanisms. Therefore, greater fluctuations could occur in urine than in blood, better reflecting the changes in human body. The roadmap of urine biomarker era was proposed. Although urine analysis has been attempted for clinical diagnosis, and urine has been monitored during the progression of many diseases, particularly urinary system diseases, whether urine can reflect brain disease status remains uncertain. As some biomarkers of brain diseases can be detected in the body fluids such as cerebrospinal fluid and blood, there is a possibility that urine also contain biomarkers of brain diseases. This review summarizes the clues of brain diseases reflected in the urine proteome and metabolome. Copyright © 2016 The Authors. Production and hosting by Elsevier Ltd.. All rights reserved.

  15. Urine biomarkers in the early stages of diseases: current status and perspective.

    PubMed

    Jing, Jian; Gao, Youhe

    2018-02-01

    As a noninvasive and easily available biological fluid, the urine is becoming an important source for disease biomarker study. Change is essential for the usefulness of a biomarker. Without homeostasis mechanisms, urine can accommodate more changes, especially in the early stages of diseases. In this review, we summarize current status and discuss perspectives on the discovery of urine biomarkers in the early stages of diseases. We emphasize the advantages of urine biomarkers compared to plasma biomarkers for the diagnosis of diseases at early stages, propose a urine biomarker research roadmap, and highlight a novel membrane storage technique that enables large-scale urine sample collection and storage efficiently and economically. It is anticipated that urine biomarker studies will greatly promote early diagnosis, prevention, treatment, and prognosis of a variety of diseases, and provide strong support for translational and precision medicine.

  16. Evaluation of open versus closed urine collection systems and development of nosocomial bacteriuria in dogs.

    PubMed

    Sullivan, Lauren A; Campbell, Vicki L; Onuma, Serene C

    2010-07-15

    To determine whether use of a closed urine collection system would decrease the incidence of nosocomial bacteriuria in hospitalized dogs, compared with use of an open urine collection system (used, sterile IV bags). Randomized controlled trial. 51 hospitalized dogs requiring indwelling urinary catheterization for >or= 24 hours. Dogs were randomly assigned to an open or closed urine collection system group. A standardized protocol for catheter placement and maintenance was followed for all dogs. A baseline urine sample was collected via cystocentesis for aerobic bacterial culture, with additional urine samples obtained daily from the urine collection reservoir. 27 dogs were assigned to the open urine collection system group, and 24 were assigned to the closed urine collection system group. The incidence of nosocomial bacteriuria in dogs with open urine collection systems (3/27 [11.1%]) was not significantly different from incidence in dogs with closed urine collection systems (2/24 [8.3%]). Median duration of catheterization was 2 days for dogs in both groups; the range was 1 to 7 days for dogs in the open group and 1 to 5 days for dogs in the closed group. Results suggested that for dogs requiring short-term indwelling urinary catheterization, the type of urine collection system (open vs closed) was not associated with likelihood of developing nosocomial bacteriuria. Use of a strict protocol for urinary catheter placement and maintenance was likely key in the low incidence of nosocomial bacteriuria in the present study.

  17. Urine cup for collection of urine from cows.

    PubMed

    Fellner, V; Weiss, M F; Belo, A T; Belyea, R L; Martz, F A; Orma, A H

    1988-08-01

    A urine cup for continuous and complete collection of urine from cows was constructed from Plastisol, cotton webb strapping, Velcro Brand touch fasteners [corrected], snap-fasteners, denim patches, weather stripping, and vacuum hose. The urine cup was made from Plastisol using a heated lead mold. It was large enough to enclose a 9 cm x 6 cm area around the vulva of a cow and was attached by strapping and Velcro Brand touch fasteners [corrected] to patches glued to the rump. Urine cups were used repeatedly and provided for long-term collection of urine from cows, eliminating the need for indwelling catheters. Applications include long-term nutrient balance, radioisotope, and metabolism studies.

  18. The fascinating story of urine examination: From uroscopy to the era of microscopy and beyond.

    PubMed

    Magiorkinis, Emmanouil; Diamantis, Aristidis

    2015-12-01

    The purpose of this study was to present the evolution of ideas on the examination of urine from antiquity till our days. A thorough study of texts, medical books from antiquity till twentieth century along with a thorough review of the available literature in PubMed was conducted. The first observation on urine examination can be traced back to the Babylonian and Sumerian texts. Almost all physicians in antiquity including Hippocrates referred to the value of urine examination in the diagnosis and prognosis of diseases. The construction of first compound microscope lead to the examination of urine sediment and the development of Urine Cytology which was revolutionized during the twentieth century with the studies of important cytologists such as George Papanicolaou, Geoffrey Krabbe, and Leopold Koss. The introduction of molecular tests in the diagnosis of urothelial cancer inaugurated a new era in the study of urine cytology. The history of urine examination spans a period of 6,000 years. The application of microscope in the examination of urine sediment during the nineteenth century established urine analysis as an important diagnostic tool in clinical practice. © 2015 Wiley Periodicals, Inc.

  19. An approach to standardization of urine sediment analysis via suggestion of a common manual protocol.

    PubMed

    Ko, Dae-Hyun; Ji, Misuk; Kim, Sollip; Cho, Eun-Jung; Lee, Woochang; Yun, Yeo-Min; Chun, Sail; Min, Won-Ki

    2016-01-01

    The results of urine sediment analysis have been reported semiquantitatively. However, as recent guidelines recommend quantitative reporting of urine sediment, and with the development of automated urine sediment analyzers, there is an increasing need for quantitative analysis of urine sediment. Here, we developed a protocol for urine sediment analysis and quantified the results. Based on questionnaires, various reports, guidelines, and experimental results, we developed a protocol for urine sediment analysis. The results of this new protocol were compared with those obtained with a standardized chamber and an automated sediment analyzer. Reference intervals were also estimated using new protocol. We developed a protocol with centrifugation at 400 g for 5 min, with the average concentration factor of 30. The correlation between quantitative results of urine sediment analysis, the standardized chamber, and the automated sediment analyzer were generally good. The conversion factor derived from the new protocol showed a better fit with the results of manual count than the default conversion factor in the automated sediment analyzer. We developed a protocol for manual urine sediment analysis to quantitatively report the results. This protocol may provide a mean for standardization of urine sediment analysis.

  20. The efficacy of semi-quantitative urine protein-to-creatinine (P/C) ratio for the detection of significant proteinuria in urine specimens in health screening settings.

    PubMed

    Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh

    2016-01-01

    Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.

  1. Dairy farm effluent effects on urine patch nitrous oxide and carbon dioxide emissions.

    PubMed

    Clough, Tim J; Kelliher, Francis M

    2005-01-01

    Dairy farm effluent (DFE) comprises animal feces, urine, and wash-down water collected at the milking shed. This is collected daily during the milking season and sprayed onto grazed dairy pastures. Urine patches in grazed pastures make a significant contribution to anthropogenic N(2)O emissions. The DFE could potentially mitigate N(2)O emissions by influencing the N(2)O to dinitrogen (N(2)) ratio, since it contains water-soluble carbon (WSC). Alternatively, DFE may enhance N(2)O emissions from urine patches. The application of DFE may also provide a substrate for the production of CO(2) in pasture soils. The effects of DFE on the CO(2) and N(2)O emissions from urine patches are unknown. Thus a laboratory experiment was performed where repeated DFE applications were made to repacked soil cores. Dairy farm effluent was applied at 0, 7, or 14 d after urine deposition. The urine was applied once on Day 0. Urine contained (15)N-enriched urea. Measurements of N(2)O, N(2), and carbon dioxide (CO(2)) fluxes, soil pH, and soil inorganic N concentrations were made. After 43 d the DFE had not mitigated N(2)O fluxes from urine patches. A small increase in the N(2)O flux occurred from the urine-treated soils where DFE was applied 1 wk after urine deposition. The amount of WSC applied in the DFE proved to be insignificant compared with the amount of soil C released as CO(2) following urine application. The priming of soil C in urine patches has implications for the understanding of soil C processes in grazed pasture ecosystems and the budgeting of C within these ecosystems.

  2. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing

    PubMed Central

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  3. Importance of Urine Dipstick in Evaluation of Young Febrile Infants With Positive Urine Culture: A Spanish Pediatric Emergency Research Group Study.

    PubMed

    Velasco, Roberto; Benito, Helvia; Mozun, Rebeca; Trujillo, Juan E; Merino, Pedro A; de la Torre, Mercedes; Gomez, Borja; Mintegi, Santiago

    2016-12-01

    Guidelines from the American Academy of Pediatrics define urinary tract infection (UTI) as the growth of greater than 50,000 ufc/mL of a single bacterium in a urine culture with a positive urine dipstick or with a urinalysis associated. Our objective was to evaluate the adequacy of this cutoff point for the diagnosis of UTI in young febrile infants. Subanalysis of a prospective multicenter study developed in RISeuP-SPERG Network between October 11 and September 13. To carry out the study, it was performed a comparison of analytical and microbiological characteristics of patients younger than 90 days with fever without focus, taking into account the results of urine dipstick and urine culture. Of a total of 3333 infants younger than 90 days with fever without focus which were included in the study, 538 were classified as UTI in accordance with American Academy of Pediatrics' guidelines. These patients were similar to those who had a positive urine dipstick and a urine culture yielding of 10,000 to 50,000 ufc/mL, and they were different from those who had a normal urine dipstick and a urine culture >50,000 ufc/mL, being focused on the isolated bacteria and blood biomarkers values. Forty-five invasive bacterial infections were diagnosed (5.9% of the 756 with a urine culture >10,000 ufc/mL). Half of the infants with a normal urine dipstick diagnosed with invasive bacterial infections were younger than 15 days. It might be inadequate to use a threshold of 50,000 cfu/mL to consider a urine culture as positive in young febrile infants given the fact that it would misdiagnose several UTIs.

  4. Evaluation of the performance of Human Papillomavirus testing in paired urine and clinician-collected cervical samples among women aged over 30 years in Bhutan.

    PubMed

    Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2017-04-08

    Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.

  5. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.

    PubMed

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-05-17

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.

  6. The Clinical Urine Culture: Enhanced Techniques Improve Detection of Clinically Relevant Microorganisms

    PubMed Central

    Price, Travis K.; Dune, Tanaka; Hilt, Evann E.; Thomas-White, Krystal J.; Kliethermes, Stephanie; Brincat, Cynthia; Brubaker, Linda; Wolfe, Alan J.

    2016-01-01

    Enhanced quantitative urine culture (EQUC) detects live microorganisms in the vast majority of urine specimens reported as “no growth” by the standard urine culture protocol. Here, we evaluated an expanded set of EQUC conditions (expanded-spectrum EQUC) to identify an optimal version that provides a more complete description of uropathogens in women experiencing urinary tract infection (UTI)-like symptoms. One hundred fifty adult urogynecology patient-participants were characterized using a self-completed validated UTI symptom assessment (UTISA) questionnaire and asked “Do you feel you have a UTI?” Women responding negatively were recruited into the no-UTI cohort, while women responding affirmatively were recruited into the UTI cohort; the latter cohort was reassessed with the UTISA questionnaire 3 to 7 days later. Baseline catheterized urine samples were plated using both standard urine culture and expanded-spectrum EQUC protocols: standard urine culture inoculated at 1 μl onto 2 agars incubated aerobically; expanded-spectrum EQUC inoculated at three different volumes of urine onto 7 combinations of agars and environments. Compared to expanded-spectrum EQUC, standard urine culture missed 67% of uropathogens overall and 50% in participants with severe urinary symptoms. Thirty-six percent of participants with missed uropathogens reported no symptom resolution after treatment by standard urine culture results. Optimal detection of uropathogens could be achieved using the following: 100 μl of urine plated onto blood (blood agar plate [BAP]), colistin-nalidixic acid (CNA), and MacConkey agars in 5% CO2 for 48 h. This streamlined EQUC protocol achieved 84% uropathogen detection relative to 33% detection by standard urine culture. The streamlined EQUC protocol improves detection of uropathogens that are likely relevant for symptomatic women, giving clinicians the opportunity to receive additional information not currently reported using standard urine culture techniques. PMID:26962083

  7. Urine sample (image)

    MedlinePlus

    A "clean-catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head ... water and rinse well. A small amount of urine should initially fall into the toilet bowl before ...

  8. Steve Rummel | NREL

    Science.gov Websites

    Module Intercomparison," Proc. Solar Energies Technologies Review Meeting Nov. 7-10, 2005, NREL tech . Rummel, D.R. Myers, T.L. Stoffel, and D. Waddington, "A Comparison of Photovoltaic Calibration

  9. Czech results at criticality dosimetry intercomparison 2002.

    PubMed

    Frantisek, Spurný; Jaroslav, Trousil

    2004-01-01

    Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal dosimetry service can give a reliable estimation of criticality accident exposure. It was found that the first system furnishes quite reliable estimation of accidental doses. For routine individual dosimetry system, no important problems were encountered in the case of photon dosemeters (TLDs, film badge). For etched track detectors in contact with the 232Th or 235U-Al alloy, the track density saturation for the spark counting method limits the upper dose at approximately 1 Gy for neutrons with the energy >1 MeV.

  10. Future Directions in Simulating Solar Geoengineering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kravitz, Benjamin S.; Robock, Alan; Boucher, Olivier

    2014-08-05

    Solar geoengineering is a proposed set of technologies to temporarily alleviate some of the consequences of anthropogenic greenhouse gas emissions. The Geoengineering Model Intercomparison Project (GeoMIP) created a framework of geoengineering simulations in climate models that have been performed by modeling centers throughout the world (B. Kravitz et al., The Geoengineering Model Intercomparison Project (GeoMIP), Atmospheric Science Letters, 12(2), 162-167, doi:10.1002/asl.316, 2011). These experiments use state-of-the-art climate models to simulate solar geoengineering via uniform solar reduction, creation of stratospheric sulfate aerosol layers, or injecting sea spray into the marine boundary layer. GeoMIP has been quite successful in its mission ofmore » revealing robust features and key uncertainties of the modeled effects of solar geoengineering.« less

  11. The Impact of Abrupt Suspension of Solar Radiation Management (Termination Effect) in Experiment G2 of the Geoengineering Model Intercomparison Project (GeoMIP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Andrew; Haywood, J.; Alterskjaer, Kari

    2013-09-11

    We have examined changes in climate which result from the sudden termination of geoengineering after 50 years of offsetting a 1% per annum increase in CO2 concentra- tions as simulated by 11 different climate models in experiment G2 of the Geoengineering Model Intercomparison Project. The models agree on a rapid rate of global-mean warming following termination, accompanied by increases in global-mean precipitation rate and in plant net primary productivity, and decreases in sea-ice cover. While there is a considerable degree of consensus for the geographical distribution of warming, there is much less of an agreement regarding the patterns of changemore » in the other quantities.« less

  12. The Cloud Feedback Model Intercomparison Project Observational Simulator Package: Version 2

    NASA Astrophysics Data System (ADS)

    Swales, Dustin J.; Pincus, Robert; Bodas-Salcedo, Alejandro

    2018-01-01

    The Cloud Feedback Model Intercomparison Project Observational Simulator Package (COSP) gathers together a collection of observation proxies or satellite simulators that translate model-simulated cloud properties to synthetic observations as would be obtained by a range of satellite observing systems. This paper introduces COSP2, an evolution focusing on more explicit and consistent separation between host model, coupling infrastructure, and individual observing proxies. Revisions also enhance flexibility by allowing for model-specific representation of sub-grid-scale cloudiness, provide greater clarity by clearly separating tasks, support greater use of shared code and data including shared inputs across simulators, and follow more uniform software standards to simplify implementation across a wide range of platforms. The complete package including a testing suite is freely available.

  13. SUMCOR: Cascade summing correction for volumetric sources applying MCNP6.

    PubMed

    Dias, M S; Semmler, R; Moreira, D S; de Menezes, M O; Barros, L F; Ribeiro, R V; Koskinas, M F

    2018-04-01

    The main features of code SUMCOR developed for cascade summing correction for volumetric sources are described. MCNP6 is used to track histories starting from individual points inside the volumetric source, for each set of cascade transitions from the radionuclide. Total and FEP efficiencies are calculated for all gamma-rays and X-rays involved in the cascade. Cascade summing correction is based on the matrix formalism developed by Semkow et al. (1990). Results are presented applying the experimental data sent to the participants of two intercomparisons organized by the ICRM-GSWG and coordinated by Dr. Marie-Cristine Lépy from the Laboratoire National Henri Becquerel (LNE-LNHB), CEA, in 2008 and 2010, respectively and compared to the other participants in the intercomparisons. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Estimation of Daily Sodium and Potassium Excretion Using Spot Urine and 24-Hour Urine Samples in a Black Population (Benin).

    PubMed

    Mizéhoun-Adissoda, Carmelle; Houehanou, Corine; Chianéa, Thierry; Dalmay, François; Bigot, André; Preux, Pierre-Marie; Bovet, Pascal; Houinato, Dismand; Desport, Jean-Claude

    2016-07-01

    The 24-hour urine collection method is considered the gold standard for the estimation of ingested potassium and sodium. Because of the impracticalities of collecting all urine over a 24-hour period, spot urine is often used for epidemiological investigations. This study aims to assess the agreement between spot urine and 24-hour urine measurements to determine sodium and potassium intake. A total of 402 participants aged 25 to 64 years were randomly selected in South Benin. Spot urine was taken during the second urination of the day. Twenty-four-hour urine was also collected. Samples (2-mL) were taken and then stored at -20°C. The analysis was carried out using potentiometric dosage. The agreement between spot urine and 24-hour urine measurements was established using Bland-Altman plots. A total of 354 results were analyzed. Daily sodium chloride and potassium chloride urinary excretion means were 10.2±4.9 g/24 h and 2.9±1.4 g/24 h, respectively. Estimated daily sodium chloride and potassium chloride means from the spot urine were 10.7±7.0 g/24 h and 3.9±2.1 g/24 h, respectively. Concordance coefficients were 0.61 at d=-0.5 g, (d±2SD=-11 g and 10.1 g) for sodium chloride and 0.61 at d=-1 g, (d±2SD=-3.8 g and 1.8 g) for potassium chloride. Spot urine method is acceptable for estimating 24-hour urinary sodium and potassium excretion to assess sodium and potassium intake in a black population. However, the confidence interval for the mean difference, which is too large, makes the sodium chloride results inadmissible at a clinical level. © 2015 Wiley Periodicals, Inc.

  15. Voided Midstream Urine Culture and Acute Cystitis in Premenopausal Women

    PubMed Central

    Hooton, Thomas M; Roberts, Pacita L.; Cox, Marsha E.; Stapleton, Ann E.

    2014-01-01

    BACKGROUND The cause of acute uncomplicated cystitis is determined on the basis of cultures of voided midstream urine, but few data guide the interpretation of such results, especially when gram-positive bacteria grow. METHODS Women from 18 to 49 years of age with symptoms of cystitis provided specimens of midstream urine, after which we collected urine by means of a urethral catheter for culture (catheter urine). We compared microbial species and colony counts in the paired specimens. The primary outcome was a comparison of positive predictive values and negative predictive values of organisms grown in midstream urine, with the presence or absence of the organism in catheter urine used as the reference. RESULTS The analysis of 236 episodes of cystitis in 226 women yielded 202 paired specimens of midstream urine and catheter urine that could be evaluated. Cultures were positive for uropathogens in 142 catheter specimens (70%), 4 of which had more than one uropathogen, and in 157 midstream specimens (78%). The presence of Escherichia coli in midstream urine was highly predictive of bladder bacteriuria even at very low counts, with a positive predictive value of 102 colony-forming units (CFU) per milliliter of 93% (Spearman’s r = 0.944). In contrast, in midstream urine, enterococci (in 10% of cultures) and group B streptococci (in 12% of cultures) were not predictive of bladder bacteriuria at any colony count (Spearman’s r = 0.322 for enterococci and 0.272 for group B streptococci). Among 41 episodes in which enterococcus, group B streptococci, or both were found in midstream urine, E. coli grew from catheter urine cultures in 61%. CONCLUSIONS Cultures of voided midstream urine in healthy premenopausal women with acute uncomplicated cystitis accurately showed evidence of bladder E. coli but not of enterococci or group B streptococci, which are often isolated with E. coli but appear to rarely cause cystitis by themselves. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases.) PMID:24224622

  16. Interaction of melamine and di-(2-ethylhexyl) phthalate exposure on markers of early renal damage in children: The 2011 Taiwan food scandal.

    PubMed

    Wu, Chia-Fang; Hsiung, Chao A; Tsai, Hui-Ju; Tsai, Yi-Chun; Hsieh, Hui-Min; Chen, Bai-Hsiun; Wu, Ming-Tsang

    2018-04-01

    Melamine and phthalate, mainly di-(2-ethylhexyl) phthalate (DEHP), are ubiquitously present in the general environment. We investigated whether urine melamine levels can modify the relationship between DEHP exposure and markers of early renal damage in children. A nationwide health survey for Children aged ≤12 years possibly exposed to phthalates were enrolled between August 2012 and January 2013. They were administered questionnaires to collect details regarding past DEHP exposure to phthalate-tainted foodstuffs. Urine samples were measured melamine levels, phthalate metabolites and biomarkers of renal damage, including urine microalbumin/creatinine ratio (ACR), N-acetyl-beta-d-glucosaminidase (NAG), and β2-microglobulin. The study included 224 children who had a median urine melamine level (μg/mmol creatinine) of 1.61 ranging 0.18-47.42. Positive correlations were found between urine melamine levels and urine ACR as well as urine NAG levels (both Spearman correlation coefficients r = 0.24, n = 224, p < .001). The higher the past DEHP exposure or urine melamine levels, the higher the prevalence of microalbuminuria. An interaction effect was also found between urine melamine levels and past DEHP exposure on urine ACR. Melamine levels may further modify the effect of past DEHP exposure on urine ACR in children. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Calcium Stone Growth in Urine from Cystic Fibrosis Patients and Healthy Controls

    NASA Astrophysics Data System (ADS)

    McSorley, Anita; Jones, Andrew M.; Webb, A. Kevin; Rao, P. Nagaraj; Kavanagh, John P.

    2007-04-01

    Cystic fibrosis patients have an increased risk of renal stone disease. There is some evidence that this may be related to a different excretory pattern of stone risk factors, but an alternative hypothesis, that the urine of cystic fibrosis patients is deficient in urinary inhibitors of crystallization and stone formation has not been tested. Here we have grown calcium stones, in vitro, in the presence of urine from healthy controls and compared this with growth in the presence of urine from cystic fibrosis patients. A stone farm was used to grow twelve calcium stones simultaneously, firstly in artificial urine for about 200 hours and then in 90% whole human urine for another 500 hours. Six of the stones received urine from healthy controls and six received urine from adult cystic fibrosis patients. There were no significant differences in stone mass at any of the key time points or in the overall growth pattern (p>0.05) between stones destined for, or treated with, urine from CF patients and the controls. Human urine greatly inhibited stone growth in vitro but there was no difference in the growth rate in urine from healthy controls and CF patients. This refutes the hypothesis that a tendency for a higher prevalence of urinary stones in CF patients is related to a deficiency in inhibitory activity.

  18. Pitfalls of diagnosing urinary tract infection in infants and young children.

    PubMed

    Yamasaki, Yasuhito; Uemura, Osamu; Nagai, Takuhito; Yamakawa, Satoshi; Hibi, Yoshiko; Yamamoto, Masaki; Nakano, Masaru; Kasahara, Katsuaki; Bo, Zhang

    2017-07-01

    The aim of this study was to examine the sensitivity and specificity of pyuria-based diagnosis of urinary tract infection (UTI) in urine collected by transurethral catheterization, and the reliability of diagnosis of pyuria in urine collected in a perineal bag. The gold standard for UTI diagnosis is significant colony counts of a single organism in urine obtained in a sterile manner. We enrolled 301 patients who underwent medical examination at the present hospital for possible UTI between January 2005 and December 2009. We collected 438 urine samples by transurethral catheterization. We investigated the accuracy of pyuria-based diagnosis of UTI using transurethral catheterization urine specimens, and the reliability of diagnosis of pyuria using bag-collected urine specimens. The false-negative rate of UTI diagnosis based on pyuria in transurethral catheterization urine sediments was 9.0%; there was no significant difference in the false-negative rate of UTI diagnosis between boys and girls. Approximately 28% of pyuria-positive bag-collected urine specimens were pyuria negative on transurethral catheterization; this rate was significantly higher in girls than in boys (56.7% vs. 8.9%, P < 0.0001). The absence of pyuria in transurethral catheterization urine sediments does not rule out UTI. Pyuria in bag-collected urine specimens frequently consists of urine leukocytes from external genitalia as well as from the urinary tract. © 2017 Japan Pediatric Society.

  19. Uranium Associations with Kidney Outcomes Vary by Urine Concentration Adjustment Method

    PubMed Central

    Shelley, Rebecca; Kim, Nam-Soo; Parsons, Patrick J.; Lee, Byung-Kook; Agnew, Jacqueline; Jaar, Bernard G.; Steuerwald, Amy J.; Matanoski, Genevieve; Fadrowski, Jeffrey; Schwartz, Brian S.; Todd, Andrew C.; Simon, David; Weaver, Virginia M.

    2017-01-01

    Uranium is a ubiquitous metal that is nephrotoxic at high doses. Few epidemiologic studies have examined the kidney filtration impact of chronic environmental exposure. In 684 lead workers environmentally exposed to uranium, multiple linear regression was used to examine associations of uranium measured in a four-hour urine collection with measured creatinine clearance, serum creatinine- and cystatin-C-based estimated glomerular filtration rates, and N-acetyl-β-D-glucosaminidase (NAG). Three methods were utilized, in separate models, to adjust uranium levels for urine concentration - μg uranium/g creatinine; μg uranium/L and urine creatinine as separate covariates; and μg uranium/4 hr. Median urine uranium levels were 0.07 μg/g creatinine and 0.02 μg/4 hr and were highly correlated (rs =0.95). After adjustment, higher ln-urine uranium was associated with lower measured creatinine clearance and higher NAG in models that used urine creatinine to adjust for urine concentration but not in models that used total uranium excreted (μg/4 hr). These results suggest that, in some instances, associations between urine toxicants and kidney outcomes may be statistical, due to the use of urine creatinine in both exposure and outcome metrics, rather than nephrotoxic. These findings support consideration of non-creatinine-based methods of adjustment for urine concentration in nephrotoxicant research. PMID:23591699

  20. Effect of injected rotenone on the production and composition of urine from the rainbow trout (Salmo gairdneri)

    USGS Publications Warehouse

    Erickson, D.A.; Gingerich, W.H.

    1986-01-01

    Renal function was evaluated in adult rainbow trout (Salmo gairdneri) dosed i.a. with rotenone at 225 and 275 μg/kg. The chemical composition of urine samples and urine flow rates collected over a 5-h pretreatment period were compared with hourly urine samples collected over a 5-h posttreatment period. Significant increases in osmolality and in concentrations of sodium, potassium, chloride, glucose, and total protein were observed in the urine of treated fish. Urine solute concentrations reached maximum values within 1 to 3 h after treatment and decreased thereafter, indicating that the effects were reversible. Concentrations of sodium and chloride were highly correlated in 2-h posttreatment urine samples at the low (r = 0.922) and high (r = 0.981) rotenone treatments. Urine flow rates were reduced in trout at each dose of rotenone but the decrease in volume of urine voided was not dose-dependent. In a separate study, [14C]polyethylene glycol was used as a filtration marker to determine the effect of rotenone treatment (225 &mu:g/kg) on urine flow rate, glomerular filtration rate, and renal water reabsorption. We showed that posttreatment urine flow rates were reduced partly by reduced glomerular filtration and partly by increased water reabsorption. Transient increases in plasma osmolality and hematocrit also were observed 0.5 h after rotenone treatment.

  1. Calcium in Urine Test: MedlinePlus Lab Test Information

    MedlinePlus

    ... medlineplus.gov/labtests/calciuminurinetest.html Calcium in Urine Test To use the sharing features on this page, ... enable JavaScript. What is a Calcium in Urine Test? A calcium in urine test measures the amount ...

  2. Crystals in Urine Test: MedlinePlus Lab Test Information

    MedlinePlus

    ... medlineplus.gov/labtests/crystalsinurinetest.html Crystals in Urine Test To use the sharing features on this page, ... enable JavaScript. What is a Crystals in Urine Test? Your urine contains many chemicals. Sometimes these chemicals ...

  3. Stability of cannabinoids in urine in three storage temperatures.

    PubMed

    Golding Fraga, S; Díaz-Flores Estévez, J; Díaz Romero, C

    1998-01-01

    Stability of cannabinoid compounds in urine samples were evaluated using several storage temperatures. Appreciable losses (> 22.4 percent) were observed in some urine samples, after being stored at room temperature for 10 days. Lower losses (8.1 percent) were observed when the urine samples were refrigerated for 4 weeks. The behavior of urine samples depended on the analyzed urine. This could be due to the different stability of the cannabinoids present in each urine sample. Important losses of 8.0 +/- 10.6, 15.8 +/- 4.2, and 19.6 +/- 6.7 percent were found when the urine samples were frozen during 40 days, 1 year, and 3 years, respectively. Average losses (> > 5 percent) can be observed after one day which could mainly be due to the decrease of the solubility of 11-nor-U9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) or adsorption process of cannabinoid molecules to the plastic storage containers.

  4. Urine benzodiazepines screening of involuntarily drugged and robbed or raped patients.

    PubMed

    Boussairi, A; Dupeyron, J P; Hernandez, B; Delaitre, D; Beugnet, L; Espinoza, P; Diamant-Berger, O

    1996-01-01

    This study involved 35 patients who claimed to have been drugged before being robbed or raped, despite urine negative toxicologic screening by immunoenzymatic methods. The urines were frozen for further investigations, including enzymatic hydrolysis of urinary conjugates, liquid-solid extraction and, finally, immunoenzymatic screening of concentrated urine extract. Urine benzodiazepines were analyzed by immunoenzymatic assay before and after enzymatic hydrolysis combined with extraction. On direct immunoenzymatic screening, 17 of the 35 urine samples were benzodiazepine positive. Enrichment of preserved specimens improved the detection threshold from 200 ng/mL to 50 ng/mL and 10 of the 18 negative urines became positive. This method allowed us to demonstrate the benzodiazepines in half of previously negative urine samples. Benzodiazepine screening is particularly problematic because of low dosage, rapid elimination, failure to detect conjugated metabolites by immunoenzymatic reagents and high threshold of sensitivity for certain substances.

  5. Development of urine glucose meter based on micro-planer amperometric biosensor and its clinical application for self-monitoring of urine glucose.

    PubMed

    Miyashita, Mariko; Ito, Narushi; Ikeda, Satoshi; Murayama, Tatsuro; Oguma, Koji; Kimura, Jun

    2009-01-01

    The highly sensitive urine glucose meter based on amperometric glucose sensor was developed and commercialized. It shows remarkable performances of wide measurement range in 0-2000 mgdl(-1), rapid response time as 6s and robustness against influence by interferents like ascorbic acid or acetaminophen. Correlation between the developed urine glucose meter and commercialized clinical-use urine glucose analyzer showed excellent linear relationship. The monitoring of postmeal blood glucose levels by assess of urine glucose of actual subjects was performed with the developed urine glucose meter. The experimental results suggest the urine glucose level 120 min following the meal should be the appropriate index for diabetes or impaired glucose tolerance to control blood glucose level. The new portable meter was developed, and is expected for flexible use at places other than home or office.

  6. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  7. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  8. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  9. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  10. The reliability and validity of using the urine dipstick test by patient self-assessment for urinary tract infection screening in spinal cord injury patients.

    PubMed

    Duanngai, Krit; Sirasaporn, Patpiya; Ngaosinchai, Siriwan Surapaitoon

    2017-01-01

    The aim of this is to evaluate the reliability of the urine dipstick test by patients' self-assessment for urinary tract infection (UTI) screening and to determine the validity of urine dipstick test. Rehabilitation Department, Srinagarind Hospital, Thailand. A diagnostic study. This study compared the urine dipstick test (index test) with the National Institute on Disability and Rehabilitation Research (NIDRR) criteria (gold standard test) in spinal cord injury (SCI) patients. The urine dipstick test informed positive and negative results. Besides the NIDRR criteria classified as UTI and no UTI. The interrater reliability was measured in the sense of Kappa whereas the validity of urine dipstick test was reported in terms of sensitivity, specificity, positive likelihood ratio (LR) (+LR), negative LR (-LR), positive predictive value (PPV), and negative predictive value (NPV). Out of the 56 participants, the kappa of urine dipstick test for leukocyte esterase, nitrite, and combined leukocyte esterase and nitrite were 0.09, 0.21, and 0.52, respectively. The nitrite urine dipstick test showed the highest sensitivity (90%). The combined leukocyte esterase and nitrite urine dipstick test gave the highest specificity (87%), PPV (60%), NPV (93%), and +LR (5.63). The interrater reliability of combined leukocyte esterase and nitrite urine dipstick test was moderate agreement. The combined leukocyte esterase and nitrite urine dipstick test showed high level of both sensitivity and specificity. The combined leukocyte esterase and nitrite urine dipstick test should be promoted for patients' self-assessment for UTI screening in SCI patients.

  11. Development of an Inline Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Banelle R.

    2008-01-01

    Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

  12. Male urine signals social rank in the Mozambique tilapia (Oreochromis mossambicus)

    PubMed Central

    Barata, Eduardo N; Hubbard, Peter C; Almeida, Olinda G; Miranda, António; Canário, Adelino VM

    2007-01-01

    Background The urine of freshwater fish species investigated so far acts as a vehicle for reproductive pheromones affecting the behaviour and physiology of the opposite sex. However, the role of urinary pheromones in intra-sexual competition has received less attention. This is particularly relevant in lek-breeding species, such as the Mozambique tilapia (Oreochromis mossambicus), where males establish dominance hierarchies and there is the possibility for chemical communication in the modulation of aggression among males. To investigate whether males use urine during aggressive interactions, we measured urination frequency of dye-injected males during paired interactions between size-matched males. Furthermore, we assessed urinary volume stored in the bladder of males in a stable social hierarchy and the olfactory potency of their urine by recording of the electro-olfactogram. Results Males released urine in pulses of short duration (about one second) and markedly increased urination frequency during aggressive behaviour, but did not release urine whilst submissive. In the stable hierarchy, subordinate males stored less urine than males of higher social rank; the olfactory potency of the urine was positively correlated with the rank of the male donor. Conclusion Dominant males store urine and use it as a vehicle for odorants actively released during aggressive disputes. The olfactory potency of the urine is positively correlated with the social status of the male. We suggest that males actively advertise their dominant status through urinary odorants which may act as a 'dominance' pheromone to modulate aggression in rivals, thereby contributing to social stability within the lek. PMID:18076759

  13. Mobile Technology Application for Improved Urine Concentration Measurement Pilot Study.

    PubMed

    Walawender, Laura; Patterson, Jeremy; Strouse, Robert; Ketz, John; Saxena, Vijay; Alexy, Emily; Schwaderer, Andrew

    2018-01-01

    Objectives: Low hydration has a deleterious effect on many conditions. In the absence of a urine concentrating defect, urine concentration is a marker of hydration status. However, markers to evaluate hydration status have not been well studied in children. The objectives of this paper are to compare measures of thirst and urine concentration in children and to develop a novel mobile technology application to measure urine concentration. Study Design: Children age 12-17 years were selected ( n = 21) for this pilot study. Thirst perception, specific gravity (automated dipstick analysis and refractometer), and urine color scale results were correlated to urine osmolality. The technology department developed a mobile technology camera application to measure light penetrance into urine which was tested on 25 random anonymized urine samples. Results: The patients' thirst perception and color scale as well as two researchers color scale did not significantly correlate with osmolality. Correlation between osmolality and hydration markers resulted in the following Pearson coefficients: SG automated dipstick, 0.61 ( P 0.003); SG refractometer, 0.98 ( P < 0.0001); urine color scale (patient), 0.37 ( P 0.10), and light penetrance, -0.77 ( P < 0.0001). The correlation of light penetrance with osmolality was stronger than all measures except SG by refractometer and osmolality. Conclusion: The mobile technology application may be a more accurate tool for urine concentration measurement than specific gravity by automated dipstick, subjective thirst, and urine color scale, but lags behind specific gravity measured by refractometer. The mobile technology application is a step toward patient oriented hydration strategies.

  14. Associations between IVF outcomes and essential trace elements measured in follicular fluid and urine: a pilot study.

    PubMed

    Ingle, Mary E; Bloom, Michael S; Parsons, Patrick J; Steuerwald, Amy J; Kruger, Pamela; Fujimoto, Victor Y

    2017-02-01

    A hypothesis-generating pilot study exploring associations between essential trace elements measured in follicular fluid (FF) and urine and in vitro fertilization (IVF) endpoints. We recruited 58 women undergoing IVF between 2007 and 2008, and measured cobalt, chromium, copper, manganese, molybdenum, and zinc in FF (n = 46) and urine (n = 45) by inductively coupled plasma mass spectrometry (ICP-MS). We used multivariable regression models to assess the impact of FF and urine trace elements on IVF outcomes, adjusted for age, body mass index, race, and cigarette smoking. Trace elements were mostly present at lower concentrations in FF than in urine. The average number of oocytes retrieved was positively associated with higher urine cobalt, chromium, copper, and molybdenum concentrations. FF chromium and manganese were negatively associated with the proportion of mature oocytes, yet urine manganese had a positive association. FF zinc was inversely associated with average oocyte fertilization. Urine trace elements were significant positive predictors for the total number of embryos generated. FF copper predicted lower embryo fragmentation while urine copper was associated with higher embryo cell number and urine manganese with higher embryo fragmentation. No associations were detected for implantation, pregnancy, or live birth. Our results suggest the importance of trace elements in both FF and urine for intermediate, although not necessarily clinical, IVF endpoints. The results differed using FF or urine biomarkers of exposure, which may have implications for the design of clinical and epidemiologic investigations. These initial findings will form the basis of a more definitive future study.

  15. Feline urine metabolomic signature: characterization of low-molecular-weight substances in urine from domestic cats.

    PubMed

    Rivera-Vélez, Sol-Maiam; Villarino, Nicolas F

    2018-02-01

    Objectives This aim of this study was to characterize the composition and content of the feline urine metabolome. Methods Eight healthy domestic cats were acclimated at least 10 days before starting the study. Urine samples (~2 ml) were collected by ultrasound-guided cystocentesis. Samples were centrifuged at 1000 × g for 8 mins, and the supernatant was analyzed by gas chromatography/time-of-flight mass spectrometery. The urine metabolome was characterized using an untargeted metabolomics approach. Results Three hundred and eighteen metabolites were detected in the urine of the eight cats. These molecules are key components of at least 100 metabolic pathways. Feline urine appears to be dominated by carbohydrates, carbohydrate conjugates, organic acid and derivatives, and amino acids and analogs. The five most abundant molecules were phenaceturic acid, hippuric acid, pseudouridine phosphate and 3-(4-hydroxyphenyl) propionic acid. Conclusions and relevance This study is the first to characterize the feline urine metabolome. The results of this study revealed the presence of multiple low-molecular-weight substances that were not known to be present in feline urine. As expected, the origin of the metabolites detected in urine was diverse, including endogenous compounds and molecules biosynthesized by microbes. Also, the diet seemed to have had a relevant role on the urine metabolome. Further exploration of the urine metabolic phenotype will open a window for discovering unknown, or poorly understood, metabolic pathways. In turn, this will advance our understanding of feline biology and lead to new insights in feline physiology, nutrition and medicine.

  16. Flow meter urine testing: a practical proposition in patients attending for urodynamics?

    PubMed

    Hashim, Hashim; Abrams, Paul

    2006-05-01

    To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.

  17. Two-Dimensional Intercomparison of Stratospheric Models

    NASA Technical Reports Server (NTRS)

    Jackman, Charles H. (Editor); Seals, Robert K., Jr. (Editor); Prather, Michael J. (Editor)

    1989-01-01

    A detailed record is provided for the examination of fundamental differences in photochemistry and transport among atmospheric models. The results of 16 different modeling groups are presented for several model experiments.

  18. Does Performing Preplacement Workplace Hair Drug Testing Influence US Department of Transportation Random and Postaccident Urine Drug Test Positivity Rates?

    PubMed

    Price, James W

    Does performing pre-employment hair drug testing subsequently affect the prevalence of positive random and postaccident urine drug tests? This cross-sectional study was designed to evaluate the prevalence of positive postaccident and random workplace urine drug tests for companies that perform pre-employment hair and urine drug testing to companies that only perform pre-employment urine drug testing. Fisher exact test of independence indicated no significant difference between pre-employment hair drug testing and overall US Department of Transportation random and postaccident urine drug test positivity rates. The analysis failed to reject the null hypothesis, suggesting that pre-employment hair drug testing had no effect upon random and postaccident urine drug test positivity rates.

  19. Radionuclide cystogram

    MedlinePlus

    ... for urine reflux or a blockage in urine flow. It is most often done to evaluate people with urinary tract infections, particularly children. Normal Results A normal value is no reflux or other abnormal urine flow, and no obstruction to the flow of urine. ...

  20. Surface-enhanced Raman spectroscopy of urine by an ingenious near-infrared Raman spectrometer

    NASA Astrophysics Data System (ADS)

    Feng, Shangyuan; Chen, Weiwei; Li, Yongzeng; Chen, Guannan; Huang, Zufang; Liao, Xiaohua; Xie, Zhiming; Chen, Rong

    2007-11-01

    This paper demonstrates the potential of an elaborately devised near-infrared Raman system in analysis of urine. The broad band in the long-wavelength region of the electronic absorption spectra of the sol with added adsorbent at certain concentrations has been explained in terms of the aggregation of the colloidal silver particles. We have reported the surface-enhanced Raman (SERS) spectra of urine, and studied the silver solution enhanced effects on the urine Raman scattering. The Raman bands of human's urine was assigned to certain molecule vibrations. We have found that different donators have dissimilar SERS of urine in different physiological condition. Comparatively few studies have explored the ability of Raman spectroscopy for the analysis of urine acid. In the present report, we investigated the ability of surface enhanced Raman spectroscopy to measure uric acid in the human urine. The results suggested that the present Raman system holds considerable promise for practical use. Practical applications such as the quantitative medical examination of urine metabolites may also be feasible in the near future.

  1. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  2. A study on the migration and transformation law of nitrogen in urine in municipal wastewater transportation and treatment.

    PubMed

    Wuang, Ren; Pengkang, Jin; Chenggang, Liang; Xiaochang, Wang; Lei, Zhang

    2013-01-01

    Many studies suggest that the total nitrogen (TN) in urine is around 9,000 mg/L and about 80% of nitrogen in municipal wastewater comes from urine, because nitrogen mainly occurs in the form of urea in fresh human urine. Based on this fact, the study on the migration and transformation law of nitrogen in urine and its influencing factors was carried out. It can be seen from the experimental results that the transformation rate of urea in urine into ammonia nitrogen after standing for 20 days is only about 18.2%, but the urea in urine can be hydrolyzed into ammonia nitrogen rapidly after it is catalyzed directly with free urease or indirectly with microorganism. Adding respectively a certain amount of urease, activated sludge and septic-tank sludge to urine samples can make the maximum transformation rate achieve 85% after 1 day, 2 days and 6 days, respectively. In combination with some corresponding treatment methods, recycling of nitrogen in urine can be achieved. The results are of great significance in guiding denitrification in municipal wastewater treatment.

  3. Effectiveness of Preanalytic Practices on Contamination and Diagnostic Accuracy of Urine Cultures: a Laboratory Medicine Best Practices Systematic Review and Meta-analysis

    PubMed Central

    Franek, Jacob; Leibach, Elizabeth K.; Weissfeld, Alice S.; Kraft, Colleen S.; Sautter, Robert L.; Baselski, Vickie; Rodahl, Debra; Peterson, Edward J.; Cornish, Nancy E.

    2015-01-01

    SUMMARY Background. Urinary tract infection (UTI) in the United States is the most common bacterial infection, and urine cultures often make up the largest portion of workload for a hospital-based microbiology laboratory. Appropriately managing the factors affecting the preanalytic phase of urine culture contributes significantly to the generation of meaningful culture results that ultimately affect patient diagnosis and management. Urine culture contamination can be reduced with proper techniques for urine collection, preservation, storage, and transport, the major factors affecting the preanalytic phase of urine culture. Objectives. The purposes of this review were to identify and evaluate preanalytic practices associated with urine specimens and to assess their impact on the accuracy of urine culture microbiology. Specific practices included collection methods for men, women, and children; preservation of urine samples in boric acid solutions; and the effect of refrigeration on stored urine. Practice efficacy and effectiveness were measured by two parameters: reduction of urine culture contamination and increased accuracy of patient diagnosis. The CDC Laboratory Medicine Best Practices (LMBP) initiative's systematic review method for assessment of quality improvement (QI) practices was employed. Results were then translated into evidence-based practice guidelines. Search strategy. A search of three electronic bibliographic databases (PubMed, SCOPUS, and CINAHL), as well as hand searching of bibliographies from relevant information sources, for English-language articles published between 1965 and 2014 was conducted. Selection criteria. The search contained the following medical subject headings and key text words: urinary tract infections, UTI, urine/analysis, urine/microbiology, urinalysis, specimen handling, preservation, biological, preservation, boric acid, boric acid/borate, refrigeration, storage, time factors, transportation, transport time, time delay, time factor, timing, urine specimen collection, catheters, indwelling, urinary reservoirs, continent, urinary catheterization, intermittent urethral catheterization, clean voided, midstream, Foley, suprapubic, bacteriological techniques, and microbiological techniques. Main results. Both boric acid and refrigeration adequately preserved urine specimens prior to their processing for up to 24 h. Urine held at room temperature for more than 4 h showed overgrowth of both clinically significant and contaminating microorganisms. The overall strength of this body of evidence, however, was rated as low. For urine specimens collected from women, there was no difference in rates of contamination for midstream urine specimens collected with or without cleansing. The overall strength of this evidence was rated as high. The levels of diagnostic accuracy of midstream urine collection with or without cleansing were similar, although the overall strength of this evidence was rated as low. For urine specimens collected from men, there was a reduction in contamination in favor of midstream clean-catch over first-void specimen collection. The strength of this evidence was rated as high. Only one study compared midstream collection with cleansing to midstream collection without cleansing. Results showed no difference in contamination between the two methods of collection. However, imprecision was due largely to the small event size. The diagnostic accuracy of midstream urine collection from men compared to straight catheterization or suprapubic aspiration was high. However, the overall strength of this body of evidence was rated as low. For urine specimens collected from children and infants, the evidence comparing contamination rates for midstream urine collection with cleansing, midstream collection without cleansing, sterile urine bag collection, and diaper collection pointed to larger reductions in the odds of contamination in favor of midstream collection with cleansing over the other methods of collection. This body of evidence was rated as high. The accuracy of diagnosis of urinary tract infection from midstream clean-catch urine specimens, sterile urine bag specimens, or diaper specimens compared to straight catheterization or suprapubic aspiration was varied. Authors' conclusions. No recommendation for or against is made for delayed processing of urine stored at room temperature, refrigerated, or preserved in boric acid. This does not preclude the use of refrigeration or chemical preservatives in clinical practice. It does indicate, however, that more systematic studies evaluating the utility of these measures are needed. If noninvasive collection is being considered for women, midstream collection with cleansing is recommended, but no recommendation for or against is made for midstream collection without cleansing. If noninvasive collection is being considered for men, midstream collection with cleansing is recommended and collection of first-void urine is not recommended. No recommendation for or against is made for collection of midstream urine without cleansing. If noninvasive collection is being considered for children, midstream collection with cleansing is recommended and collection in sterile urine bags, from diapers, or midstream without cleansing is not recommended. Whether midstream collection with cleansing can be routinely used in place of catheterization or suprapubic aspiration is unclear. The data suggest that midstream collection with cleansing is accurate for the diagnosis of urinary tract infections in infants and children and has higher average accuracy than sterile urine bag collection (data for diaper collection were lacking); however, the overall strength of evidence was low, as multivariate modeling could not be performed, and thus no recommendation for or against can be made. PMID:26598386

  4. Comparison of two preparatory techniques for urine cytology.

    PubMed Central

    Dhundee, J; Rigby, H S

    1990-01-01

    Two methods of preparation of urine for cytology were compared retrospectively. In method 1 cells in the urine were fixed after the preparation of the smear; in method 2 the cells were fixed before smear preparation. Urine cytology reports were correlated with subsequent histological analysis. The specificities of urine cytology using both methods were high (99%). The sensitivity using method 1 was 87%; using method 2 it was 65%. This difference was significant. The cell preparation technique therefore significantly changes the sensitivity of urine cytology. Cellular fixation after smear preparation is preferable to smear preparation after fixation. PMID:2266176

  5. Response of Tabanidae (Diptera) to different natural attractants.

    PubMed

    Krcmar, Stjepan; Mikuska, Alma; Merdić, Enrih

    2006-12-01

    The response of female tabanids to natural attractants was studied in the Monjoros Forest along the Nature Park Kopacki rit in eastern Croatia. Tabanids were caught in canopy traps baited with either aged cow, horse, sheep, or pig urine and also in unbaited traps. Tabanids were collected in a significantly higher numbers in traps baited with natural attractants compared to unbaited traps. The number of females of Tabanus bromius, Tabanus maculicornis, Tabanus tergestinus, and Hybomitra bimaculata collected from canopy traps baited with cow urine and traps baited with other natural attractants differed significantly. Females of Haematopota pluvialis were also collected more frequently in canopy traps baited with aged cow urine than in those with aged horse urine, but this difference was not significant. However, the number of females of Haematopota pluvialis collected from canopy traps baited with other natural attractants (sheep and pig urine) differed significantly when compared with aged cow urine baited traps. Canopy traps baited with aged cow urine collected significantly more Tabanus sudeticus than did traps baited with aged pig urine. Finally, the aged cow urine baited canopy traps collected 51 times more tabanids than unbaited traps, while aged horse, aged sheep, and aged pig urine baited traps collected 36, 30, and 22 times as many tabanids, respectively, than unbaited traps.

  6. Urine Bacterial Community Convergence through Fertilizer Production: Storage, Pasteurization, and Struvite Precipitation.

    PubMed

    Lahr, Rebecca H; Goetsch, Heather E; Haig, Sarah J; Noe-Hays, Abraham; Love, Nancy G; Aga, Diana S; Bott, Charles B; Foxman, Betsy; Jimenez, Jose; Luo, Ting; Nace, Kim; Ramadugu, Kirtana; Wigginton, Krista R

    2016-11-01

    Source-separated human urine was collected from six public events to study the impact of urine processing and storage on bacterial community composition and viability. Illumina 16S rRNA gene sequencing revealed a complex community of bacteria in fresh urine that differed across collection events. Despite the harsh chemical conditions of stored urine (pH > 9 and total ammonia nitrogen > 4000 mg N/L), bacteria consistently grew to 5 ± 2 × 10 8 cells/mL. Storing hydrolyzed urine for any amount of time significantly reduced the number of operational taxonomic units (OTUs) to 130 ± 70, increased Pielou evenness to 0.60 ± 0.06, and produced communities dominated by Clostridiales and Lactobacillales. After 80 days of storage, all six urine samples from different starting materials converged to these characteristics. Urine pasteurization or struvite precipitation did not change the microbial community, even when pasteurized urine was stored for an additional 70 days. Pasteurization decreased metabolic activity by 50 ± 10% and additional storage after pasteurization did not lead to recovery of metabolic activity. Urine-derived fertilizers consistently contained 16S rRNA genes belonging to Tissierella, Erysipelothrix, Atopostipes, Bacteroides, and many Clostridiales OTUs; additional experiments must determine whether pathogenic species are present, responsible for observed metabolic activity, or regrow when applied.

  7. Inter-comparison of source apportionment of PM10 using PMF and CMB in three sites nearby an industrial area in central Italy

    NASA Astrophysics Data System (ADS)

    Cesari, Daniela; Donateo, Antonio; Conte, Marianna; Contini, Daniele

    2016-12-01

    Receptor models (RMs), based on chemical composition of particulate matter (PM), such as Chemical Mass Balance (CMB) and Positive Matrix Factorization (PMF), represent useful tools for determining the impact of PM sources to air quality. This information is useful, especially in areas influenced by anthropogenic activities, to plan mitigation strategies for environmental management. Recent inter-comparison of source apportionment (SA) results showed that one of the difficulties in the comparison of estimated source contributions is the compatibility of the sources, i.e. the chemical profiles of factor/sources used in receptor models. This suggests that SA based on integration of several RMs could give more stable and reliable solutions with respect to a single model. The aim of this work was to perform inter-comparison of PMF (using PMF3.0 and PMF5.0 codes) and CMB outputs, focusing on both source chemical profiles and estimates of source contributions. The dataset included 347 daily PM10 samples collected in three sites in central Italy located near industrial emissions. Samples were chemically analysed for the concentrations of 21 chemical species (NH4+, Ca2 +, Mg2 +, Na+, K+, Mg2 +, SO42 -, NO3-, Cl-, Si, Al, Ti, V, Mn, Fe, Ni, Cu, Zn, Br, EC, and OC) used as input of RMs. The approach identified 9 factor/sources: marine, traffic, resuspended dust, biomass burning, secondary sulphate, secondary nitrate, crustal, coal combustion power plant and harbour-industrial. Results showed that the application of constraints in PMF5.0 improved interpretability of profiles and comparability of estimated source contributions with stoichiometric calculations. The inter-comparison of PMF and CMB gave significant differences for secondary nitrate, biomass burning, and harbour-industrial sources, due to non-compatibility of these source profiles that have local specificities. When these site-dependent specificities were taken into account, optimising the input source profiles of CMB, a significant improvement in the comparison of the estimated source contributions with PMF was obtained.

  8. Intercomparison of retrospective radon detectors.

    PubMed Central

    Field, R W; Steck, D J; Parkhurst, M A; Mahaffey, J A; Alavanja, M C

    1999-01-01

    We performed both a laboratory and a field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, (210)Pb, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha-emission of a (210)Pb-decay product, (210)Po. The detector's track density generation rate (tracks per square centimeter per hour) is proportional to the surface alpha-activity. In the absence of other strong sources of alpha-emission in the glass, the implanted surface alpha-activity should be proportional to the accumulated (210)Po, and hence to the cumulative radon gas exposure. The goals of the intercomparison were to a) perform collocated measurements using two different glass-based retrospective radon detectors in a controlled laboratory environment to compare their relative response to implanted polonium in the absence of environmental variation, b) perform collocated measurements using two different retrospective radon progeny detectors in a variety of residential settings to compare their detection of glass-implanted polonium activities, and c) examine the correlation between track density rates and contemporary radon gas concentrations. The laboratory results suggested that the materials and methods used by the studies produced similar track densities in detectors exposed to the same implanted (210)Po activity. The field phase of the intercomparison found excellent agreement between the track density rates for the two types of retrospective detectors. The correlation between the track density rates and direct contemporary radon concentration measurements was relatively high, considering that no adjustments were performed to account for either the residential depositional environment or glass surface type. Preliminary comparisons of the models used to translate track rate densities to average long-term radon concentrations differ between the two studies. Further calibration of the retrospective detectors' models for interpretation of track rate density may allow the pooling of studies that use glass-based retrospective radon detectors to determine historic residential radon exposures. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 PMID:10545336

  9. Biogeochemical Protocols and Diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP)

    NASA Technical Reports Server (NTRS)

    Orr, James C.; Najjar, Raymond G.; Aumont, Olivier; Bopp, Laurent; Bullister, John L.; Danabasoglu, Gokhan; Doney, Scott C.; Dunne, John P.; Dutay, Jean-Claude; Graven, Heather; hide

    2017-01-01

    The Ocean Model Intercomparison Project (OMIP) focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6). OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations) vs. when integrated within fully coupled Earth system models (CMIP6). Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948-2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF [subscript] 6) and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen). Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1) will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup) will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation protocols are founded on those from previous phases of the Ocean Carbon-Cycle Model Intercomparison Project. They have been merged and updated to reflect improvements concerning gas exchange, carbonate chemistry, and new data for initial conditions and atmospheric gas histories. Code is provided to facilitate their implementation.

  10. Compatibility of different measurement techniques of global solar radiation and application for long-term observations at Izaña Observatory

    NASA Astrophysics Data System (ADS)

    Delia García, Rosa; Cuevas, Emilio; García, Omaira Elena; Ramos, Ramón; Romero-Campos, Pedro Miguel; de Ory, Fernado; Cachorro, Victoria Eugenia; de Frutos, Angel

    2017-03-01

    A 1-year inter-comparison of classical and modern radiation and sunshine duration (SD) instruments has been performed at Izaña Atmospheric Observatory (IZO) located in Tenerife (Canary Islands, Spain) starting on 17 July 2014. We compare daily global solar radiation (GSRH) records measured with a Kipp & Zonen CM-21 pyranometer, taken in the framework of the Baseline Surface Radiation Network, with those measured with a multifilter rotating shadowband radiometer (MFRSR), a bimetallic pyranometer (PYR) and GSRH estimated from sunshine duration performed by a Campbell-Stokes sunshine recorder (CS) and a Kipp & Zonen sunshine duration sensor (CSD). Given that the BSRN GSRH records passed strict quality controls (based on principles of physical limits and comparison with the LibRadtran model), they have been used as reference in the inter-comparison study. We obtain an overall root mean square error (RMSE) of ˜ 0.9 MJm-2 (4 %) for PYR and MFRSR GSRH, 1.9 (7 %) and 1.2 MJm-2 (5 %) for CS and CSD GSRH, respectively. Factors such as temperature, relative humidity (RH) and the solar zenith angle (SZA) have been shown to moderately affect the GSRH observations. As an application of the methodology developed in this work, we have re-evaluated the GSRH data time series obtained at IZO with two PYRs between 1977 and 1991. Their high consistency and temporal stability have been proved by comparing with GSRH estimates obtained from SD observations. These results demonstrate that (1) the continuous-basis inter-comparison of different GSRH techniques offers important diagnostics for identifying inconsistencies between GSRH data records, and (2) the GSRH measurements performed with classical and more simple instruments are consistent with more modern techniques and, thus, valid to recover GSRH data time series and complete worldwide distributed GSRH data. The inter-comparison and quality assessment of these different techniques have allowed us to obtain a complete and consistent long-term global solar radiation series (1977-2015) at Izaña.

  11. Inter-comparison of three-dimensional models of volcanic plumes

    USGS Publications Warehouse

    Suzuki, Yujiro; Costa, Antonio; Cerminara, Matteo; Esposti Ongaro, Tomaso; Herzog, Michael; Van Eaton, Alexa; Denby, Leif

    2016-01-01

    We performed an inter-comparison study of three-dimensional models of volcanic plumes. A set of common volcanological input parameters and meteorological conditions were provided for two kinds of eruptions, representing a weak and a strong eruption column. From the different models, we compared the maximum plume height, neutral buoyancy level (where plume density equals that of the atmosphere), and level of maximum radial spreading of the umbrella cloud. We also compared the vertical profiles of eruption column properties, integrated across cross-sections of the plume (integral variables). Although the models use different numerical procedures and treatments of subgrid turbulence and particle dynamics, the inter-comparison shows qualitatively consistent results. In the weak plume case (mass eruption rate 1.5 × 106 kg s− 1), the vertical profiles of plume properties (e.g., vertical velocity, temperature) are similar among models, especially in the buoyant plume region. Variability among the simulated maximum heights is ~ 20%, whereas neutral buoyancy level and level of maximum radial spreading vary by ~ 10%. Time-averaging of the three-dimensional (3D) flow fields indicates an effective entrainment coefficient around 0.1 in the buoyant plume region, with much lower values in the jet region, which is consistent with findings of small-scale laboratory experiments. On the other hand, the strong plume case (mass eruption rate 1.5 × 109 kg s− 1) shows greater variability in the vertical plume profiles predicted by the different models. Our analysis suggests that the unstable flow dynamics in the strong plume enhances differences in the formulation and numerical solution of the models. This is especially evident in the overshooting top of the plume, which extends a significant portion (~ 1/8) of the maximum plume height. Nonetheless, overall variability in the spreading level and neutral buoyancy level is ~ 20%, whereas that of maximum height is ~ 10%. This inter-comparison study has highlighted the different capabilities of 3D volcanic plume models, and identified key features of weak and strong plumes, including the roles of jet stability, entrainment efficiency, and particle non-equilibrium, which deserve future investigation in field, laboratory, and numerical studies.

  12. Biogeochemical protocols and diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP)

    NASA Astrophysics Data System (ADS)

    Orr, James C.; Najjar, Raymond G.; Aumont, Olivier; Bopp, Laurent; Bullister, John L.; Danabasoglu, Gokhan; Doney, Scott C.; Dunne, John P.; Dutay, Jean-Claude; Graven, Heather; Griffies, Stephen M.; John, Jasmin G.; Joos, Fortunat; Levin, Ingeborg; Lindsay, Keith; Matear, Richard J.; McKinley, Galen A.; Mouchet, Anne; Oschlies, Andreas; Romanou, Anastasia; Schlitzer, Reiner; Tagliabue, Alessandro; Tanhua, Toste; Yool, Andrew

    2017-06-01

    The Ocean Model Intercomparison Project (OMIP) focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6). OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations) vs. when integrated within fully coupled Earth system models (CMIP6). Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948-2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF6) and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen). Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1) will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup) will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation protocols are founded on those from previous phases of the Ocean Carbon-Cycle Model Intercomparison Project. They have been merged and updated to reflect improvements concerning gas exchange, carbonate chemistry, and new data for initial conditions and atmospheric gas histories. Code is provided to facilitate their implementation.

  13. Revisiting the PLUMBER Experiments from a Process-Diagnostics Perspective

    NASA Astrophysics Data System (ADS)

    Nearing, G. S.; Ruddell, B. L.; Clark, M. P.; Nijssen, B.; Peters-Lidard, C. D.

    2017-12-01

    The PLUMBER benchmarking experiments [1] showed that some of the most sophisticated land models (CABLE, CH-TESSEL, COLA-SSiB, ISBA-SURFEX, JULES, Mosaic, Noah, ORCHIDEE) were outperformed - in simulations of half-hourly surface energy fluxes - by instantaneous, out-of-sample, and globally-stationary regressions with no state memory. One criticism of PLUMBER is that the benchmarking methodology was not derived formally, so that applying a similar methodology with different performance metrics can result in qualitatively different results. Another common criticism of model intercomparison projects in general is that they offer little insight into process-level deficiencies in the models, and therefore are of marginal value for helping to improve the models. We address both of these issues by proposing a formal benchmarking methodology that also yields a formal and quantitative method for process-level diagnostics. We apply this to the PLUMBER experiments to show that (1) the PLUMBER conclusions were generally correct - the models use only a fraction of the information available to them from met forcing data (<50% by our analysis), and (2) all of the land models investigated by PLUMBER have similar process-level error structures, and therefore together do not represent a meaningful sample of structural or epistemic uncertainty. We conclude by suggesting two ways to improve the experimental design of model intercomparison and/or model benchmarking studies like PLUMBER. First, PLUMBER did not report model parameter values, and it is necessary to know these values to separate parameter uncertainty from structural uncertainty. This is a first order requirement if we want to use intercomparison studies to provide feedback to model development. Second, technical documentation of land models is inadequate. Future model intercomparison projects should begin with a collaborative effort by model developers to document specific differences between model structures. This could be done in a reproducible way using a unified, process-flexible system like SUMMA [2]. [1] Best, M.J. et al. (2015) 'The plumbing of land surface models: benchmarking model performance', J. Hydrometeor. [2] Clark, M.P. et al. (2015) 'A unified approach for process-based hydrologic modeling: 1. Modeling concept', Water Resour. Res.

  14. Intercomparison of retrospective radon detectors.

    PubMed

    Field, R W; Steck, D J; Parkhurst, M A; Mahaffey, J A; Alavanja, M C

    1999-11-01

    We performed both a laboratory and a field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, (210)Pb, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha-emission of a (210)Pb-decay product, (210)Po. The detector's track density generation rate (tracks per square centimeter per hour) is proportional to the surface alpha-activity. In the absence of other strong sources of alpha-emission in the glass, the implanted surface alpha-activity should be proportional to the accumulated (210)Po, and hence to the cumulative radon gas exposure. The goals of the intercomparison were to a) perform collocated measurements using two different glass-based retrospective radon detectors in a controlled laboratory environment to compare their relative response to implanted polonium in the absence of environmental variation, b) perform collocated measurements using two different retrospective radon progeny detectors in a variety of residential settings to compare their detection of glass-implanted polonium activities, and c) examine the correlation between track density rates and contemporary radon gas concentrations. The laboratory results suggested that the materials and methods used by the studies produced similar track densities in detectors exposed to the same implanted (210)Po activity. The field phase of the intercomparison found excellent agreement between the track density rates for the two types of retrospective detectors. The correlation between the track density rates and direct contemporary radon concentration measurements was relatively high, considering that no adjustments were performed to account for either the residential depositional environment or glass surface type. Preliminary comparisons of the models used to translate track rate densities to average long-term radon concentrations differ between the two studies. Further calibration of the retrospective detectors' models for interpretation of track rate density may allow the pooling of studies that use glass-based retrospective radon detectors to determine historic residential radon exposures.

  15. GEO-LEO reflectance band inter-comparison with BRDF and atmospheric scattering corrections

    NASA Astrophysics Data System (ADS)

    Chang, Tiejun; Xiong, Xiaoxiong Jack; Keller, Graziela; Wu, Xiangqian

    2017-09-01

    The inter-comparison of the reflective solar bands between the instruments onboard a geostationary orbit satellite and onboard a low Earth orbit satellite is very helpful to assess their calibration consistency. GOES-R was launched on November 19, 2016 and Himawari 8 was launched October 7, 2014. Unlike the previous GOES instruments, the Advanced Baseline Imager on GOES-16 (GOES-R became GOES-16 after November 29 when it reached orbit) and the Advanced Himawari Imager (AHI) on Himawari 8 have onboard calibrators for the reflective solar bands. The assessment of calibration is important for their product quality enhancement. MODIS and VIIRS, with their stringent calibration requirements and excellent on-orbit calibration performance, provide good references. The simultaneous nadir overpass (SNO) and ray-matching are widely used inter-comparison methods for reflective solar bands. In this work, the inter-comparisons are performed over a pseudo-invariant target. The use of stable and uniform calibration sites provides comparison with appropriate reflectance level, accurate adjustment for band spectral coverage difference, reduction of impact from pixel mismatching, and consistency of BRDF and atmospheric correction. The site in this work is a desert site in Australia (latitude -29.0 South; longitude 139.8 East). Due to the difference in solar and view angles, two corrections are applied to have comparable measurements. The first is the atmospheric scattering correction. The satellite sensor measurements are top of atmosphere reflectance. The scattering, especially Rayleigh scattering, should be removed allowing the ground reflectance to be derived. Secondly, the angle differences magnify the BRDF effect. The ground reflectance should be corrected to have comparable measurements. The atmospheric correction is performed using a vector version of the Second Simulation of a Satellite Signal in the Solar Spectrum modeling and BRDF correction is performed using a semi-empirical model. AHI band 1 (0.47μm) shows good matching with VIIRS band M3 with difference of 0.15%. AHI band 5 (1.69μm) shows largest difference in comparison with VIIRS M10.

  16. Changes in urine composition after trauma facilitate bacterial growth

    PubMed Central

    2012-01-01

    Background Critically ill patients including trauma patients are at high risk of urinary tract infection (UTI). The composition of urine in trauma patients may be modified due to inflammation, systemic stress, rhabdomyolysis, life support treatment and/or urinary catheter insertion. Methods Prospective, single-centre, observational study conducted in patients with severe trauma and without a history of UTIs or recent antibiotic treatment. The 24-hour urine samples were collected on the first and the fifth days and the growth of Escherichia coli in urine from patients and healthy volunteers was compared. Biochemical and hormonal modifications in urine that could potentially influence bacterial growth were explored. Results Growth of E. coli in urine from trauma patients was significantly higher on days 1 and 5 than in urine of healthy volunteers. Several significant modifications of urine composition could explain these findings. On days 1 and 5, trauma patients had an increase in glycosuria, in urine iron concentration, and in the concentrations of several amino acids compared to healthy volunteers. On day 1, the urinary osmotic pressure was significantly lower than for healthy volunteers. Conclusion We showed that urine of trauma patients facilitated growth of E. coli when compared to urine from healthy volunteers. This effect was present in the first 24 hours and until at least the fifth day after trauma. This phenomenon may be involved in the pathophysiology of UTIs in trauma patients. Further studies are required to define the exact causes of such modifications. PMID:23194649

  17. Serum and urine inorganic fluoride concentrations and urine oxalate concentrations following methoxyflurane anesthesia in the dog.

    PubMed

    Brunson, D B; Stowe, C M; McGrath, C J

    1979-02-01

    Plasma fluoride, urine fluoride and urine oxalate concentrations were measured before administering an anesthetic to 8 dogs, and at 0, 3, 9, 24, 48, and 72 hours following 1.5 hours of anesthesia with 1% methoxyflurane. Plasma and urine osmolalities were measured and compared with fluoride and oxalate values. Fluoride concentration increased in both plasma and urine following anesthesia when compared with the preanesthetic concentrations. Maximum mean plasma inorganic fluoride was 106.71 mumoles per liter (+/- 25.44 SE) at 9 hours after exposure to methoxyflurane was completed. By 72 hours after exposure to methoxyflurane the plasma fluoride concentration was 23.47 microM/L (+/- 5.74 SE). Mean urine inorganic fluoride concentration was highest at 9 hours after exposure to methoxyflurane and reached 6047.03 microM/L (+/- 1378.46 SE) as compared to the mean preanesthetic base-line concentration of 542.68 microM/L (+/- 132.93 SE), and the 72 hour mean urine fluoride concentration which was 1593.78 microM/L (+/- 579.46 SE). Urine oxalate concentrations, when compared with urine osmolality (mg/mOsm), increased throughout the study. The 72-hour concentration after exposure to methoxyflurane was 2.5 times the preanesthetic (mg/mOsm) oxalate concentration. Plasma osmolality did not change markedly during the study. Urine osmolalities varied between animals and collection times, but a consistent pattern did not occur. Clinical and laboratory signs of renal dysfunction were not observed in any animal during the study.

  18. Generation of Mesenchymal-Like Stem Cells From Urine in Pediatric Patients.

    PubMed

    He, W; Zhu, W; Cao, Q; Shen, Y; Zhou, Q; Yu, P; Liu, X; Ma, J; Li, Y; Hong, K

    2016-01-01

    Mesenchymal stem cells (MSCs) have been widely used for regenerative medicine. Traditionally, the procedures of MSC isolation are usually invasive and time-consuming. Urine is merely a body waste, and recent studies have suggested that urine represents an alternative source of stem cells. We, therefore, determined whether the possibility of isolating mesenchymal-like stem cells was practical from human urine. A total of 16 urine samples were collected from pediatric patients. Urine-derived cells were isolated, expanded, and identified for specific cell surface markers using flow cytometry. Cell morphology was observed by microscopy. Osteogenic and adipogenic differentiation potential were determinded by culturing cells in specific induction medium, and assessed by alkaline phosphatase and oil red O stainings, respectively. Clones were established and passaged successfully from primary cultures of urine cells. Cultured urine-derived cells at passage 3 were fusiform and arranged with certain directionality. Urine-derived cells at passage 5 displayed expressions of cell surface markers (CD29, CD105, CD166, CD90, and CD13). There was no expression of the general hematopoietic cell markers (CD45, CD34, and HLA-DR). Under in vitro induction conditions, urine-derived cells at passage 5 were able to differentiate into osteoblasts, but not adipocytes. Urine may be a noninvasive source for mesenchymal-like stem cells. These cells could potentially provide a new source of autologous stem cells for regenerative medicine and cell therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Advances in the Diagnosis of Human Opisthorchiasis: Development of Opisthorchis viverrini Antigen Detection in Urine

    PubMed Central

    Duenngai, Kunyarat; Wangboon, Chompunoot; Sithithaworn, Jiraporn; Watwiengkam, Nattaya; Namwat, Nisana; Techasen, Anchalee; Loilome, Watcharin; Yongvanit, Puangrat; Loukas, Alex; Sithithaworn, Paiboon; Bethony, Jeffrey M.

    2015-01-01

    Background Many strategies to control opisthorchiasis have been employed in Thailand, but not in the other neighbouring countries. Specific control methods include mass drug administration (MDA) and health education to reduce raw fish consumption. These control efforts have greatly shifted the epidemiology of Opisthorchis viverrini (OV) infection over the last decade from presenting as densely concentrated "heavy" infections in single villages to widespread "light" OV infections distributed over wide geographical areas. Currently, the "gold standard" detection method for OV infection is formalin ethyl-acetate concentration technique (FECT), which has limited diagnostic sensitivity and diagnostic specificity for light OV infections, with OV eggs often confused with eggs of minute intestinal flukes (MIFs) in feces. In this study, we developed and evaluated the diagnostic performance of a monoclonal antibody-based enzyme-linked immunosorbent assay for the measurement of OV excretory-secretory (ES) antigens in urine (urine OV-ES assay) for the diagnosis of opisthorchiasis compared to the gold standard detection FECT method. Methodology We tested several methods for pre-treating urine samples prior to testing the diagnostic performance of the urine OV-ES assay. Using trichloroacetic acid (TCA) pre-treated urine, we compared detection and quantification of OV infection using the urine OV-ES assay versus FECT in OV-endemic areas in Northeastern Thailand. Receiver operating characteristic (ROC) curves were used to determine the diagnostic sensitivity and specificity of the urine OV-ES assay using TCA pre-treated urine, and to establish diagnostic positivity thresholds. The Positive Predictive Value as well as the likelihood of obtaining a positive test result (LR+) or a negative test result (LR-) were calculated for the established diagnostic positivity threshold. Diagnostic risks (Odds Ratios) were estimated using logistic regression. Results When urine samples were pre-treated with TCA prior to use in the urine OV-ES assay, the analytical sensitivity was significantly improved. Using TCA pre-treatment of urine, the urine OV-ES assay had a limit of detection (LoD) of 39 ng/ml compared to the LoD of 52 ng/mL reported for coprological antigen detection methods. Similarly, the urine OV-ES assay correlated significantly with intensity of OV infection as measured by FECT. The urine OV-ES assay was also able to detect 28 individuals as positive from the 63 (44.4%) individuals previously determined to be negative using FECT. The likelihood of a positive diagnosis of OV infection by urine OV-ES assay increased significantly with the intensity of OV infection as determined by FECT. With reference to FECT, the sensitivity and specificity of the urine OV-ES assay was 81% and 70%, respectively. Conclusion The detection of OV-infection by the urine OV-ES assay showed much greater diagnostic sensitivity and diagnostic specificity than the current "gold standard" FECT method for the detection and quantification of OV infection. Due to its ease-of-use, and noninvasive sample collection (urine), the urine OV-ES assay offers the potential to revolutionize the diagnosis of liver fluke infection and provide an effective tool for control and elimination of these tumorigenic parasites. PMID:26485024

  20. Green Urine in Traditional Persian Medicine

    PubMed Central

    Kolouri, Sepideh; Daneshfard, Babak; Jaladat, Amir-Mohammad; Tafazoli, Vahid

    2016-01-01

    The color of urine is an important factor in urine examination, which can help physicians differentiate various diseases. Today, it is known that certain dyes, drug intoxications, and diseases can induce green urine discoloration. In the view of traditional Persian medicine, which is based on humoral medicine, green urine discoloration is generally referred to the dominance of coldness in the body. In fact, it is considered to be a result of a special kind of humoral imbalance and fluid depletion or retention in the human body. Persian scholars believed that green urine could be an indicator of intoxication or a predictor of an imminent spasm or convulsion in pediatric patients. Further investigations could result in finding new diagnostic scales of urine color based on the teachings of traditional Persian medicine. PMID:27103627

  1. Estimated net acid excretion inversely correlates with urine pH in vegans, lacto-ovo vegetarians, and omnivores.

    PubMed

    Ausman, Lynne M; Oliver, Lauren M; Goldin, Barry R; Woods, Margo N; Gorbach, Sherwood L; Dwyer, Johanna T

    2008-09-01

    Diet affects urine pH and acid-base balance. Both excess acid/alkaline ash (EAA) and estimated net acid excretion (NAE) calculations have been used to estimate the effects of diet on urine pH. This study's goal was to determine if free-living vegans, lacto-ovo vegetarians, and omnivores have increasingly acidic urine, and to assess the ability of EAA and estimated NAE calculations to predict urine pH. This study used a cross-sectional design. This study assessed urine samples of 10 vegan, 16 lacto-ovo vegetarian, and 16 healthy omnivorous women in the Boston metropolitan area. Six 3-day food records from each dietary group were analyzed for EAA content and estimated NAE, and correlations with measured urine pH were calculated. The mean (+/- SD) urine pH was 6.15 +/- 0.40 for vegans, 5.90 +/- 0.36 for lacto-ovo vegetarians, and 5.74 +/- 0.21 for omnivores (analysis of variance, P = .013). Calculated EAA values were not significantly different among the three groups, whereas mean estimated NAE values were significantly different: 17.3 +/- 14.5 mEq/day for vegans, 31.3 +/- 8.5 mEq/day for lacto-ovo vegetarians, and 42.6 +/- 13.2 mEq/day for omnivores (analysis of variance, P = .01). The average deattenuated correlation between urine pH and EAA was 0.333; this value was -0.768 for estimated NAE and urine pH, with a regression equation of pH = 6.33 - 0.014 NAE (P = .02, r = -0.54). Habitual diet and estimated NAE calculations indicate the probable ranking of urine pH by dietary groups, and may be used to determine the likely acid-base status of an individual; EAA calculations were not predictive of urine pH.

  2. Diagnostic accuracy of spot urine protein-to-creatinine ratio for proteinuria and its association with adverse pregnancy outcomes in Chinese pregnant patients with pre-eclampsia.

    PubMed

    Cheung, H C; Leung, K Y; Choi, C H

    2016-06-01

    International guidelines have endorsed spot urine protein-to-creatinine ratio of >30 mg protein/mmol creatinine as an alternative to a 24-hour urine sample to represent significant proteinuria. This study aimed to determine the accuracy of spot urine protein-to-creatinine ratio in predicting significant proteinuria and adverse pregnancy outcome. This case series was conducted in a regional obstetric unit in Hong Kong. A total of 120 Chinese pregnant patients with pre-eclampsia delivered at Queen Elizabeth Hospital from January 2011 to December 2013 were included. Relationship of spot urine protein-to-creatinine ratio and 24-hour proteinuria; accuracy of the ratio against 24-hour urine protein at different cut-offs; and relationship of such ratio and adverse pregnancy outcome were studied. Spot urine protein-to-creatinine ratio was correlated with 24-hour urine protein with Pearson correlation coefficient of 0.914 (P<0.0001) when the ratio was <200 mg/mmol. The optimal threshold of spot urine protein-to-creatinine ratio for diagnosing proteinuria in Chinese pregnant patients (33 mg/mmol) was similar to that stated in the international literature (30 mg/mmol). A cut-off of 20 mg/mmol provided a 100% sensitivity, and 52 mg/mmol provided a 100% specificity. There was no significant difference in spot urine protein-to-creatinine ratio between cases with and without adverse pregnancy outcome. Spot urine protein-to-creatinine ratio had a positive and significant correlation with 24-hour urine results in Chinese pre-eclamptic women when the ratio was <200 mg/mmol. Nonetheless, this ratio was not predictive of adverse pregnancy outcome.

  3. Hydration status affects urea transport across rat urothelia.

    PubMed

    Spector, David A; Deng, Jie; Stewart, Kerry J

    2011-12-01

    Although mammalian urinary tract epithelium (urothelium) is generally considered impermeable to water and solutes, recent data suggest that urine constituents may be reabsorbed during urinary tract transit and storage. To study water and solute transport across the urothelium in an in vivo rat model, we instilled urine (obtained during various rat hydration conditions) into isolated in situ rat bladders and, after a 1-h dwell, retrieved the urine and measured the differences in urine volume and concentration and total quantity of urine urea nitrogen and creatinine between instilled and retrieved urine in rat groups differing by hydration status. Although urine volume did not change >1.9% in any group, concentration (and quantity) of urine urea nitrogen in retrieved urine fell significantly (indicating reabsorption of urea across bladder urothelia), by a mean of 18% (489 mg/dl, from an instilled 2,658 mg/dl) in rats receiving ad libitum water and by a mean of 39% (2,544 mg/dl, from an instilled 6,204 mg/dl) in water-deprived rats, but did not change (an increase of 15 mg/dl, P = not significant, from an instilled 300 mg/dl) in a water-loaded rat group. Two separate factors affected urea nitrogen reabsorption rates, a urinary factor related to hydration status, likely the concentration of urea nitrogen in the instilled urine, and a bladder factor(s), also dependent on the animal's state of hydration. Urine creatinine was also absorbed during the bladder dwell, and hydration group effects on the concentration and quantity of creatinine reabsorbed were qualitatively similar to the hydration group effect on urea transport. These findings support the notion(s) that urinary constituents may undergo transport across urinary tract epithelia, that such transport may be physiologically regulated, and that urine is modified during transit and storage through the urinary tract.

  4. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode.

    PubMed

    Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj

    2016-01-01

    To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result. A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.

  5. Validation of a urine circulating cathodic antigen cassette test for detection of Schistosoma haematobiumin uMkhanyakude district of South Africa.

    PubMed

    Rubaba, O; Chimbari, M J; Soko, W; Manyangadze, T; Mukaratirwa, S

    2018-06-01

    Circulating cathodic antigen (CCA) tests for schistosomiasis are fast and less complicated allowing making them good candidates for routine qualitative screening for schistosomiasis at point of care. The urine-CCA has been evaluated for detection of S. mansoni with promising results. Its specificity and consistency in detecting S. haematobium infection in different endemic regions has been variable. This study validated a rapid urine-CCA cassette test for qualitative detection of S. haematobium infection in an S. haematobium endemic area with low S. mansoni prevalence. Microscopic examination for the standard urine filtration technique was used to validate the commercially available urine-CCA cassette test (rapid medical diagnostics ® ). The validation was done in a sample of primary school pupils (n = 420) aged 10-15 years in schools in the Jozini Municipality, KZN. There was a relationship between infection intensity and a positive urine-CCA test. Using the urine filtration method as the gold standard, the prevalence for S. haematobium was 40%, the accuracy of the CCA kit was 54.8%, sensitivity was 68.1% while the specificity was 45.8%. The positive predictive value was 45.82% while the negative predictive value was 68.05%. Both the urine filtration and the urine-CCA methods detected heavy (≥50 eggs/10 mL urine) and light infections at statistically significant levels. The overall accuracy, sensitivity and specificity of the urine-CCA cassette test were low. The urine-CCA cassette test performed much better for heavy infections than low infections (p < 0.05) implying that the kit may not be suitable for low endemic areas. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    PubMed

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  7. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  8. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  9. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  10. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  11. Misclassification of iodine intake level from morning spot urine samples with high iodine excretion among Inuit and non-Inuit in Greenland.

    PubMed

    Andersen, Stig; Waagepetersen, Rasmus; Laurberg, Peter

    2015-05-14

    Iodine nutrition is commonly assessed from iodine excretion in urine. A 24 h urine sample is ideal, but it is cumbersome and inconvenient. Hence, spot urine samples with creatinine to adjust for differences in void volume are widely used. Still, the importance of ethnicity and the timing of spot urine samples need to be settled. We, thus, collected 104 early morning spot urine samples and 24 h urine samples from Inuit and non-Inuit living in Greenland. Diet was assessed by a FFQ. Demographic data were collected from the national registry and by questionnaires. Iodine was measured using the Sandell-Kolthoff reaction, creatinine using the Jaffe method and para-amino benzoic acid by the HPLC method for the estimation of completeness of urine sampling and compensation of incomplete urine samples to 24 h excretion. A population-based recruitment was done from the capital city, a major town and a settlement (n 36/48/20). Participants were seventy-eight Inuit and twenty-six non-Inuit. The median 24 h iodine excretion was 138 (25th-75th percentile 89-225) μg/97 (25th-75th percentile 72-124) μg in Inuit/non-Inuit (P= 0.030), and 153 (25th-75th percentile 97-251) μg/102 (25th-75th percentile 73-138) μg (P= 0.026) when including compensated iodine excretion. Iodine excretion in 24 h urine samples increased with a rising intake of traditional Inuit foods (P= 0.005). Iodine excretion was lower in morning spot urine samples than in 24 h urine samples (P< 0.001). This difference was associated with iodine intake levels (P< 0.001), and was statistically significant when the iodine excretion level was above 150 μg/24 h. In conclusion, the iodine intake level was underestimated from morning spot urine samples if iodine excretion was above the recommended level.

  12. The Association Between Urine Output, Creatinine Elevation, and Death.

    PubMed

    Engoren, Milo; Maile, Michael D; Heung, Michael; Jewell, Elizabeth S; Vahabzadeh, Christie; Haft, Jonathan W; Kheterpal, Sachin

    2017-04-01

    Acute kidney injury can be defined by a fall in urine output, and urine output criteria may be more sensitive in identifying acute kidney injury than traditional serum creatinine criteria. However, as pointed out in the Kidney Disease Improving Global Outcome guidelines, the association of urine output with subsequent creatinine elevations and death is poorly characterized. The purpose of this study was to determine what degrees of reduced urine output are associated with subsequent creatinine elevation and death. This was a retrospective cohort study of adult patients (age ≥18 years) cared for in a cardiovascular intensive care unit after undergoing cardiac operations in a tertiary care university medical center. All adult patients who underwent cardiac operations and were not receiving dialysis preoperatively were studied. The development of acute kidney injury was defined as an increase in creatinine of more than 0.3 mg/dL or by more than 50% above baseline by postoperative day 3. Acute kidney injury developed in 1,061 of 4,195 patients (25%). Urine output had moderate discrimination in predicting subsequent acute kidney injury (C statistic = .637 ± .054). Lower urine output and longer duration of low urine output were associated with greater odds of developing acute kidney injury and death. We found that there is similar accuracy in using urine output corrected for actual, ideal, or adjusted weight to discriminate future acute kidney injury by creatinine elevation and recommend using actual weight for its simplicity. We also found that low urine output is associated with subsequent acute kidney injury and that the association is greater for lower urine output and for low urine output of longer durations. Low urine output (<0.2 mL · kg -1 · h -1 ), even in the absence of acute kidney injury by creatinine elevation, is independently associated with mortality. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. The potential of at-home prediction of the formation of urolithiasis by simple multi-frequency electrical conductivity of the urine and the comparison of its performance with urine ion-related indices, color and specific gravity.

    PubMed

    Silverio, Angelito A; Chung, Wen-Yaw; Cheng, Cheanyeh; Wang, Hai-Lung; Kung, Chien-Min; Chen, Jun; Tsai, Vincent F S

    2016-04-01

    It is important to control daily diet, water intake and life style as well as monitor the quality of urine for urolithiasis prevention. For decades, many ion-related indices have been developed for predicting the formation of urinary stones or urolithiasis, such as EQUILs, relative supersaturation (RSS), Tiselius indices (TI), Robertson risk factor algorithms (RRFA) and more recently, the Bonn risk index. However, they mostly demand robust laboratory analysis, are work-intensive, and even require complex computational programs to get the concentration patterns of several urine analytes. A simple and fast platform for measuring multi-frequency electrical conductivity (MFEC) of morning spot urine (random urine) to predict the onset of urolithiasis was implemented in this study. The performance thereof was compared to ion-related indices, urine color and specific gravity. The concentrations of relevant ions, color, specific gravity (SG) and MFEC (MFEC tested at 1, 10, 100, 5001 KHz and 1 MHz) of 80 random urine samples were examined after collection. Then, the urine samples were stored at 4 °C for 24 h to determine whether sedimentation would occur or not. Ion-activity product index of calcium oxalate (AP(CaOx) EQ2) was calculated. The correlation between AP(CaOx) EQ2, urine color, SG and MFEC were analyzed. AP(CaOx) EQ2, urine color and MFEC (at 5 frequencies) all demonstrated good prediction (p = 0.01, 0.01, 0.01, respectively) for stone formation. The positive correlation between AP(CaOx) EQ2 and MFEC is also significant (p = 0.01). MFEC provides a good metric for predicting the onset of urolithiasis, which is comparable to conventional ion-related indices and urine color. This technology can be implemented with much ease for objectively monitoring the quality of urine at points-of-care or at home.

  14. 28 CFR 550.41 - Urine surveillance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Urine surveillance. 550.41 Section 550.41 Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT DRUG PROGRAMS Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.41 Urine...

  15. 28 CFR 550.41 - Urine surveillance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Urine surveillance. 550.41 Section 550.41 Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT DRUG PROGRAMS Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.41 Urine...

  16. 28 CFR 550.41 - Urine surveillance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Urine surveillance. 550.41 Section 550.41 Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT DRUG PROGRAMS Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.41 Urine...

  17. 28 CFR 550.41 - Urine surveillance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Urine surveillance. 550.41 Section 550.41 Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT DRUG PROGRAMS Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.41 Urine...

  18. 28 CFR 550.41 - Urine surveillance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Urine surveillance. 550.41 Section 550.41 Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT DRUG PROGRAMS Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.41 Urine...

  19. Do You Have Symptoms of a Kidney Stone?

    MedlinePlus

    ... to a veterinarian if you see blood or crystals in the urine or signs of painful urination. Pets with stones often try to urinate frequently, but excrete only a tiny amount of urine most of the time. They will squat and strain but either nothing ...

  20. Urine phenobarbital drug screening: potential use for compliance assessment in neonates.

    PubMed

    Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P

    2012-02-01

    This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.

  1. The effect of substrate composition and storage time on urine specific gravity in dogs.

    PubMed

    Steinberg, E; Drobatz, K; Aronson, L

    2009-10-01

    The purpose of this study is to evaluate the effects of substrate composition and storage time on urine specific gravity in dogs. A descriptive cohort study of 15 dogs. The urine specific gravity of free catch urine samples was analysed during a 5-hour time period using three separate storage methods; a closed syringe, a diaper pad and non-absorbable cat litter. The urine specific gravity increased over time in all three substrates. The syringe sample had the least change from baseline and the diaper sample had the greatest change from baseline. The urine specific gravity for the litter and diaper samples had a statistically significant increase from the 1-hour to the 5-hour time point. The urine specific gravity from canine urine stored either on a diaper or in a non-absorbable litter increased over time. Although the change was found to be statistically significant over the 5-hour study period it is unlikely to be clinically significant.

  2. Stabilization of source-separated human urine by chemical oxidation.

    PubMed

    Zhang, Yang; Li, Zifu; Zhao, Yuan; Chen, Shuangling; Mahmood, Ibrahim Babatunde

    2013-01-01

    The inhibitory effect of ozone and hydrogen peroxide (HP) on urea hydrolysis in stored urine was investigated and compared. Ozone showed less effect on urea hydrolysis due to the complicated composition of urine (including a large amount of urease-producing bacteria) and bacteria regeneration. Ozone concentration and total heterotrophic bacteria analysis demonstrated that residual ozone concentration decreased by 43% within 15 hr from 13.50 to 7.72 mg/L in the one-time ozonation urine test, and finally completely decomposed within 4 days. In addition, bacteria regenerated quickly after ozone completely decomposed. However, HP showed a significant effect on inhibiting urea hydrolysis not only in stored urine but also in fecal-contaminated urine. The suitable doses of applied HP to inhibit urea hydrolysis in stored urine, concentrations of 0.5 and 1.0 g feces per liter of fecal-contaminated urine, were 0.03, 0.16 and 0.23 mol/L, respectively. The urea concentrations after 2 months stored were 7,145, 7,109 and 7,234 mg/L, respectively.

  3. Potential of non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Huang, Shaohua; Wang, Lan; Chen, Weisheng; Feng, Shangyuan; Lin, Juqiang; Huang, Zufang; Chen, Guannan; Li, Buhong; Chen, Rong

    2014-11-01

    Non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy (SERS) analysis was presented. Urine SERS spectra were measured on esophagus cancer patients (n = 56) and healthy volunteers (n = 36) for control analysis. Tentative assignments of the urine SERS spectra indicated some interesting esophagus cancer-specific biomolecular changes, including a decrease in the relative content of urea and an increase in the percentage of uric acid in the urine of esophagus cancer patients compared to that of healthy subjects. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was employed to analyze and differentiate the SERS spectra between normal and esophagus cancer urine. The diagnostic algorithms utilizing a multivariate analysis method achieved a diagnostic sensitivity of 89.3% and specificity of 83.3% for separating esophagus cancer samples from normal urine samples. These results from the explorative work suggested that silver nano particle-based urine SERS analysis coupled with PCA-LDA multivariate analysis has potential for non-invasive detection of esophagus cancer.

  4. Metabolic Acidosis or Respiratory Alkalosis? Evaluation of a Low Plasma Bicarbonate Using the Urine Anion Gap.

    PubMed

    Batlle, Daniel; Chin-Theodorou, Jamie; Tucker, Bryan M

    2017-09-01

    Hypobicarbonatemia, or a reduced bicarbonate concentration in plasma, is a finding seen in 3 acid-base disorders: metabolic acidosis, chronic respiratory alkalosis and mixed metabolic acidosis and chronic respiratory alkalosis. Hypobicarbonatemia due to chronic respiratory alkalosis is often misdiagnosed as a metabolic acidosis and mistreated with the administration of alkali therapy. Proper diagnosis of the cause of hypobicarbonatemia requires integration of the laboratory values, arterial blood gas, and clinical history. The information derived from the urinary response to the prevailing acid-base disorder is useful to arrive at the correct diagnosis. We discuss the use of urine anion gap, as a surrogate marker of urine ammonium excretion, in the evaluation of a patient with low plasma bicarbonate concentration to differentiate between metabolic acidosis and chronic respiratory alkalosis. The interpretation and limitations of urine acid-base indexes at bedside (urine pH, urine bicarbonate, and urine anion gap) to evaluate urine acidification are discussed. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  5. Adsorptive removal of sulfonamide antibiotics in livestock urine using the high-silica zeolite HSZ-385.

    PubMed

    Fukahori, S; Fujiwara, T; Funamizu, N; Matsukawa, K; Ito, R

    2013-01-01

    The adsorptive removal of seven sulfonamide antibiotics using the high-silica zeolite HSZ-385 from distilled water, synthetic urine and real porcine urine was investigated. The pH greatly affected the adsorption efficiency, and the amounts of all sulfonamide antibiotics adsorbed on HSZ-385 decreased at alkaline conditions compared with that at neutral conditions. During storage, the pH and ammonium-ion concentration increased with urea hydrolysis for porcine urine. We clarified that the adsorption efficiency of sulfonamides in synthetic urine was equivalent to that in distilled water, suggesting that adsorption behavior was not affected by coexistent ions. HSZ-385 could adsorb sulfonamide antibiotics in real porcine urine even though the non-purgeable organic carbon concentration of porcine urine was 4-7 g/L and was two orders of magnitude higher than those of sulfonamides (10 mg/L each). Moreover, the adsorption of sulfonamides reached equilibrium within 15 min, suggesting that HSZ-385 is a promising adsorbent for removing sulfonamides from porcine urine.

  6. Impact of order set design on urine culturing practices at an academic medical centre emergency department.

    PubMed

    Munigala, Satish; Jackups, Ronald R; Poirier, Robert F; Liang, Stephen Y; Wood, Helen; Jafarzadeh, S Reza; Warren, David K

    2018-01-20

    Urinalysis and urine culture are commonly ordered tests in the emergency department (ED). We evaluated the impact of removal of order sets from the 'frequently ordered test' in the computerised physician order entry system (CPOE) on urine testing practices. We conducted a before (1 September to 20 October 2015) and after (21 October to 30 November 2015) study of ED patients. The intervention consisted of retaining 'urinalysis with reflex to microscopy' as the only urine test in a highly accessible list of frequently ordered tests in the CPOE system. All other urine tests required use of additional order screens via additional mouse clicks. The frequency of urine testing before and after the intervention was compared, adjusting for temporal trends. During the study period, 6499 (28.2%) of 22 948 ED patients had ≥1 urine test ordered. Urine testing rates for all ED patients decreased in the post intervention period for urinalysis (291.5 pre intervention vs 278.4 per 1000 ED visits post intervention, P=0.03), urine microscopy (196.5vs179.5, P=0.001) and urine culture (54.3vs29.7, P<0.001). When adjusted for temporal trends, the daily culture rate per 1000 ED visits decreased by 46.6% (-46.6%, 95% CI -66.2% to -15.6%), but urinalysis (0.4%, 95% CI -30.1 to 44.4%), microscopy (-6.5%, 95% CI -36.0% to 36.6%) and catheterised urine culture rates (17.9%, 95% CI -16.9 to 67.4) were unchanged. A simple intervention of retaining only 'urinalysis with reflex to microscopy' and removing all other urine tests from the 'frequently ordered' window of the ED electronic order set decreased urine cultures ordered by 46.6% after accounting for temporal trends. Given the injudicious use of antimicrobial therapy for asymptomatic bacteriuria, findings from our study suggest that proper design of electronic order sets plays a vital role in reducing excessive ordering of urine cultures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    PubMed

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of sequestering contaminants from environmental release and allows for targeted treatment of potential health hazards prior to agricultural application. The efficacy of pathogen and pharmaceutical inactivation, transformation or removal during urine nutrient recovery processes is thus briefly reviewed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Rapid Diagnosis of Tuberculosis from Analysis of Urine Volatile Organic Compounds

    PubMed Central

    Lim, Sung H.; Martino, Raymond; Anikst, Victoria; Xu, Zeyu; Mix, Samantha; Benjamin, Robert; Schub, Herbert; Eiden, Michael; Rhodes, Paul A.; Banaei, Niaz

    2017-01-01

    The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different urine test conditions. Basified testing condition yielded the best accuracy with 85.5% sensitivity and 79.5% specificity. The CSA urine assay offers desired features needed for tuberculosis diagnosis in endemic settings. PMID:29057329

  9. Polymerase Chain Reaction Detection of Leishmania kDNA from the Urine of Peruvian Patients with Cutaneous and Mucocutaneous Leishmaniasis

    PubMed Central

    Veland, Nicolas; Espinosa, Diego; Valencia, Braulio Mark; Ramos, Ana Pilar; Calderon, Flor; Arevalo, Jorge; Low, Donald E.; Llanos-Cuentas, Alejandro; Boggild, Andrea K.

    2011-01-01

    We hypothesized that Leishmania kDNA may be present in urine of patients with cutaneous leishmaniasis (CL). Urine samples and standard diagnostic specimens were collected from patients with skin lesions. kDNA polymerase chain reaction (PCR) was performed on samples from patients and 10 healthy volunteers from non-endemic areas. Eighty-six of 108 patients were diagnosed with CL and 18 (21%) had detectable Leishmania Viannia kDNA in the urine. Sensitivity and specificity were 20.9% (95% confidence interval [CI] 12.3–29.5%) and 100%. Six of 8 patients with mucocutaneous involvement had detectable kDNA in urine versus 12 of 78 patients with isolated cutaneous disease (P < 0.001). L. (V.) braziliensis (N = 3), L. (V.) guyanensis (N = 6), and L. (V.) peruviana (N = 3) were identified from urine. No healthy volunteer or patient with an alternate diagnosis had detectable kDNA in urine. Sensitivity of urine PCR is sub-optimal for diagnosis. On the basis of these preliminary data in a small number of patients, detectable kDNA in urine may identify less localized forms of infection and inform treatment decisions. PMID:21460009

  10. Diversion of the urine stream by surgical modification of the preputial ostium in a dog.

    PubMed

    Pavletic, Michael M; Brum, Douglas E

    2009-11-01

    A 1.4-year-old sexually intact male Standard Poodle was evaluated with a history of urinating on its left forelimb and lower portion of the thorax. Physical examination revealed that the dog had an unusually elevated (tucked) abdominal wall and prominent dome-shaped thoracic wall. These anatomic changes altered the angle of the urine stream, resulting in the dog's soiling the xiphoid region of the thorax and left forelimb. The dorsal half of the preputial ostium was closed surgically to divert the urine stream in a ventral direction. The ventral portion of the ostium was reciprocally enlarged. Postoperatively, the dog urinated in a downward direction, eliminating urine contact with the body. The preputial orifice (ostium) plays an important role in the shape and direction of the urine stream exiting the penile urethra. Dogs with an elevated abdominal wall and prominent dome-shaped thorax may be prone to contamination of the lower portion of the thorax and forelimbs with urine during normal micturition. Partial closure of the dorsal preputial ostium, with reciprocal enlargement of the lower half of the orifice, can create a deflective barrier that effectively diverts the urine stream in a ventral direction.

  11. Metabolomic and elemental analysis of camel and bovine urine by GC-MS and ICP-MS.

    PubMed

    Ahamad, Syed Rizwan; Alhaider, Abdul Qader; Raish, Mohammad; Shakeel, Faiyaz

    2017-01-01

    Recent studies from the author's laboratory indicated that camel urine possesses antiplatelet activity and anti-cancer activity which is not present in bovine urine. The objective of this study is to compare the volatile and elemental components of bovine and camel urine using GC-MS and ICP-MS analysis. We are interested to know the component that performs these biological activities. The freeze dried urine was dissolved in dichloromethane and then derivatization process followed by using BSTFA for GC-MS analysis. Thirty different compounds were analyzed by the derivatization process in full scan mode. For ICP-MS analysis twenty eight important elements were analyzed in both bovine and camel urine. The results of GC-MS and ICP-MS analysis showed marked difference in the urinary metabolites. GC-MS evaluation of camel urine finds a lot of products of metabolism like benzene propanoic acid derivatives, fatty acid derivatives, amino acid derivatives, sugars, prostaglandins and canavanine. Several research reports reveal the metabolomics studies on camel urine but none of them completely reported the pharmacology related metabolomics. The present data of GC-MS suggest and support the previous studies and activities related to camel urine.

  12. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    PubMed

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  13. Stamping SERS for creatinine sensing

    NASA Astrophysics Data System (ADS)

    Li, Ming; Du, Yong; Zhao, Fusheng; Zeng, Jianbo; Santos, Greggy M.; Mohan, Chandra; Shih, Wei-Chuan

    2015-03-01

    Urine can be obtained easily, readily and non-invasively. The analysis of urine can provide metabolic information of the body and the condition of renal function. Creatinine is one of the major components of human urine associated with muscle metabolism. Since the content of creatinine excreted into urine is relatively constant, it is used as an internal standard to normalize water variations. Moreover, the detection of creatinine concentration in urine is important for the renal clearance test, which can monitor the filtration function of kidney and health status. In more details, kidney failure can be imminent when the creatinine concentration in urine is high. A simple device and protocol for creatinine sensing in urine samples can be valuable for point-of-care applications. We reported quantitative analysis of creatinine in urine samples by using stamping surface enhanced Raman scattering (S-SERS) technique with nanoporous gold disk (NPGD) based SERS substrate. S-SERS technique enables label-free and multiplexed molecular sensing under dry condition, while NPGD provides a robust, controllable, and high-sensitivity SERS substrate. The performance of S-SERS with NGPDs is evaluated by the detection and quantification of pure creatinine and creatinine in artificial urine within physiologically relevant concentration ranges.

  14. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...

  15. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...

  16. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...

  17. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...

  18. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...

  19. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  20. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    PubMed

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  1. Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.

    PubMed

    Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P

    2014-11-01

    The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.

  2. The Critical Importance of Urinary Concentrating Ability in the Generation of Urinary Carbon Dioxide Tension

    PubMed Central

    Arruda, Jose A. L.; Nascimento, Luiz; Mehta, Pradeep K.; Rademacher, Donald R.; Sehy, John T.; Westenfelder, Christof; Kurtzman, Neil A.

    1977-01-01

    Measurement of urine to blood (U-B) carbon dioxide tension (PCO2) gradient during alkalinization of the urine has been suggested to assess distal H+ secretion. A fact that has not been considered in previous studies dealing with urinary PCO2 is that dissolution of HCO3 in water results in elevation of PCO2 which is directly proportional to the HCO3 concentration. To investigate the interrelationship of urinary HCO3 and urinary acidification, we measured U-B PCO2 in (a) the presence of enhanced H+ secretion and decreased concentrating ability i.e., chronic renal failure (CRF), (b) animals with normal H+ secretion and decreased concentrating ability, Brattleboro (BB) rats, and (c) the presence of both impaired H+ secretion and concentrating ability (LiCl treatment and after release of unilateral ureteral obstruction). At moderately elevated plasma HCO3 levels (30-40 meq/liter), normal rats achieved a highly alkaline urine (urine pH > 7.8) and raised urine HCO3 concentration and U-B PCO2. At similar plasma HCO3 levels, BB rats had a much higher fractional water excretion and failed to raise urine pH, urine HCO3 concentration, and U-B PCO2 normally. At a very high plasma HCO3 (>50 meq/liter), BB rats raised urine pH, urine HCO3 concentration, and U-B PCO2 to the same levels seen in normals. CRF rats failed to raise urine pH, urine HCO3, and U-B PCO2 normally at moderately elevated plasma HCO3 levels; at very high plasma HCO3 levels, CRF rats achieved a highly alkaline urine but failed to raise U-B PCO2. Dogs and patients with CRF were also unable to raise urine pH, urine HCO3 concentration, and U-B PCO2 normally at moderately elevated plasma HCO3 levels. In rats, dogs, and man, U-B PCO2 was directly related to urine HCO3 concentration and inversely related to fractional water excretion. At moderately elevated plasma HCO3 levels, animals with a distal acidification defect failed to raise U-B PCO2; increasing the plasma HCO3 to very high levels resulted in a significant increase in urine HCO3 concentration and U-B PCO2. The observed urinary PCO2 was very close to the PCO2 which would be expected by simple dissolution of a comparable amount of HCO3 in water. These data demonstrate that, in highly alkaline urine, urinary PCO2 is largely determined by concentration of urinary HCO3 and cannot be used as solely indicating distal H+ secretion. PMID:893680

  3. Ultrafine particle measurement and related EPA research studies

    EPA Science Inventory

    Webinar slides to present information on measuring ultrafine particles at the request of the 2013 MARAMA Monitoring Committee. The talk covers near-road monitoring, instrument intercomparison, and general overview of UFP monitoring technology.

  4. Determining the Relationship between the Total and Window Channel Nighttime Radiances for the CERES Instrument

    NASA Technical Reports Server (NTRS)

    Kratz, David P.; Priestley, Kory J.; Green, Richard N.

    1999-01-01

    Observing Earth s radiant energy budget from space is critical to improving our understanding of Earth s climate system. The Earth Radiation Budget Experiment (ERBE) was the first initiative to provide simultaneous observations of Earth s radiant energy with identical instruments flying aboard separate satellites. The design of the ERBE instrument was based upon three complementary broadband radiometers which measured the shortwave (< 5 mm), longwave (> 5 mm), and total regions of the spectrum. Since any two of the ERBE radiometers could be used to simulate the third, a three channel intercomparison, based on redundancy, was available to uncover any changes in the relative sensitivities of the individual radiometers. Such a three channel intercomparison thus provided confidence in the application of the ERBE measurements over the lifetime of the instrument while mitigating the concern over instrument degradation.

  5. Intercomparisons of high-resolution solar blind Raman lidar atmospheric profiles of water vapor with radiosondes and kytoon

    NASA Technical Reports Server (NTRS)

    Petri, K.; Salik, A.; Cooney, J.

    1986-01-01

    A report is given of measurements of atmospheric profiles of water vapor in the boundary layer by use of solar blind Raman lidar. These measurement episodes, occuring twice a day over a two week period, were accompanied by a dense net of supporting measurements. The support included two radiosonde launches per measurement episodes as well as a kytoon support measurement of water vapor using a wet bulb-dry bulb instrument. The kytoon strategy included ten minute stops at strategic altitudes. Additional kytoon measurements included ozone profiles and nephelometric extinction profiles in the visible. Typically, six or seven 1000 shot lidar profile averages were collected during a measurement episode. Overall performance comparisons are provided and intercomparisons between auxiliary measurement devices are presented. Data on the accuracy of the lidar water vapor profiles are presented.

  6. A prospective evaluation of conventional cystography for detection of urine leakage at the vesicourethral anastomosis site after radical prostatectomy based on computed tomography.

    PubMed

    Han, K S; Choi, H J; Jung, D C; Park, S; Cho, K S; Joung, J Y; Seo, H K; Chung, J; Lee, K H

    2011-03-01

    To evaluate the diagnostic accuracy of conventional cystography for the detection of urine leakage at the vesicourethral anastomosis (VUA) site after radical prostatectomy based on computed tomography (CT) cystography. Patients who underwent radical prostatectomies at a single tertiary cancer centre were prospectively enrolled. Conventional cystography was routinely performed on postoperative day 7. Non-enhanced pelvic CT images were obtained after retrograde instillation of the same contrast material for a reference standard of urine leakage at the VUA site. Urine leakage was classified as follows: none; a plication abnormality; mild; moderate; and excessive. One hundred and twenty consecutive patients were enrolled. Conventional cystography detected 14 urine leakages, but CT cystography detected 40 urine leakages, which consisted of 28 mild and 12 moderate urine leakages. When using CT cystography as the standard measurement, conventional cystography showed a diagnostic accuracy of 17.8% (5/28) for mild urine leakage and 75% (9/12) for moderate leakage. Of nine patients diagnosed with mild leakage on conventional cystography, four (44.4%) had complicated moderate urine leakages based on CT cystography, requiring prolonged catheterization. The sensitivity, specificity, positive and negative predictive values, and accuracy of conventional cystography were 35, 100, 100, 75.4, and 78.3%, respectively. Conventional cystography is less accurate than CT cystography for diagnosing urine leakage at the VUA site after a radical prostatectomy. The present results suggest that CT cystography is a good choice for diagnostic imaging of urine leakage after radical prostatectomy. Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. Effect of Potassium Citrate on Calcium Phosphate Stones in a Model of Hypercalciuria

    PubMed Central

    Asplin, John R.; Frick, Kevin K.; Granja, Ignacio; Culbertson, Christopher D.; Ng, Adeline; Grynpas, Marc D.; Bushinsky, David A.

    2015-01-01

    Potassium citrate is prescribed to decrease stone recurrence in patients with calcium nephrolithiasis. Citrate binds intestinal and urine calcium and increases urine pH. Citrate, metabolized to bicarbonate, should decrease calcium excretion by reducing bone resorption and increasing renal calcium reabsorption. However, citrate binding to intestinal calcium may increase absorption and renal excretion of both phosphate and oxalate. Thus, the effect of potassium citrate on urine calcium oxalate and calcium phosphate supersaturation and stone formation is complex and difficult to predict. To study the effects of potassium citrate on urine supersaturation and stone formation, we utilized 95th-generation inbred genetic hypercalciuric stone-forming rats. Rats were fed a fixed amount of a normal calcium (1.2%) diet supplemented with potassium citrate or potassium chloride (each 4 mmol/d) for 18 weeks. Urine was collected at 6, 12, and 18 weeks. At 18 weeks, stone formation was visualized by radiography. Urine citrate, phosphate, oxalate, and pH levels were higher and urine calcium level was lower in rats fed potassium citrate. Furthermore, calcium oxalate and calcium phosphate supersaturation were higher with potassium citrate; however, uric acid supersaturation was lower. Both groups had similar numbers of exclusively calcium phosphate stones. Thus, potassium citrate effectively raises urine citrate levels and lowers urine calcium levels; however, the increases in urine pH, oxalate, and phosphate levels lead to increased calcium oxalate and calcium phosphate supersaturation. Potassium citrate induces complex changes in urine chemistries and resultant supersaturation, which may not be beneficial in preventing calcium phosphate stone formation. PMID:25855777

  8. Detection of prostate cancer-specific transcripts in extracellular vesicles isolated from post-DRE urine

    PubMed Central

    Pellegrini, Kathryn L.; Patil, Dattatraya; Douglas, Kristen J.S.; Lee, Grace; Wehrmeyer, Kathryn; Torlak, Mersiha; Clark, Jeremy; Cooper, Colin S.; Moreno, Carlos S.; Sanda, Martin G.

    2018-01-01

    Background The measurement of gene expression in post-digital rectal examination (DRE) urine specimens provides a non-invasive method to determine a patient’s risk of prostate cancer. Many currently available assays use whole urine or cell pellets for the analysis of prostate cancer-associated genes, although the use of extracellular vesicles (EVs) has also recently been of interest. We investigated the expression of prostate-, kidney-, and bladder-specific transcripts and known prostate cancer biomarkers in urine EVs. Methods Cell pellets and EVs were recovered from post-DRE urine specimens, with the total RNA yield and quality determined by Bioanalyzer. The levels of prostate, kidney, and bladder-associated transcripts in EVs were assessed by TaqMan qPCR and targeted sequencing. Results RNA was more consistently recovered from the urine EV specimens, with over 80% of the patients demonstrating higher RNA yields in the EV fraction as compared to urine cell pellets. The median EV RNA yield of 36.4 ng was significantly higher than the median urine cell pellet RNA yield of 4.8 ng. Analysis of the post-DRE urine EVs indicated that prostate-specific transcripts were more abundant than kidney- or bladder-specific transcripts. Additionally, patients with prostate cancer had significantly higher levels of the prostate cancer-associated genes PCA3 and ERG. Conclusions Post-DRE urine EVs are a viable source of prostate-derived RNAs for biomarker discovery and prostate cancer status can be distinguished from analysis of these specimens. Continued analysis of urine EVs offers the potential discovery of novel biomarkers for pre-biopsy prostate cancer detection. PMID:28419548

  9. Low urine pH and acid excretion do not predict bone fractures or the loss of bone mineral density: a prospective cohort study.

    PubMed

    Fenton, Tanis R; Eliasziw, Misha; Tough, Suzanne C; Lyon, Andrew W; Brown, Jacques P; Hanley, David A

    2010-05-10

    The acid-ash hypothesis, the alkaline diet, and related products are marketed to the general public. Websites, lay literature, and direct mail marketing encourage people to measure their urine pH to assess their health status and their risk of osteoporosis.The objectives of this study were to determine whether 1) low urine pH, or 2) acid excretion in urine [sulfate + chloride + 1.8x phosphate + organic acids] minus [sodium + potassium + 2x calcium + 2x magnesium mEq] in fasting morning urine predict: a) fragility fractures; and b) five-year change of bone mineral density (BMD) in adults. Cohort study: the prospective population-based Canadian Multicentre Osteoporosis Study. Multiple logistic regression was used to examine associations between acid excretion (urine pH and urine acid excretion) in fasting morning with the incidence of fractures (6804 person years). Multiple linear regression was used to examine associations between acid excretion with changes in BMD over 5-years at three sites: lumbar spine, femoral neck, and total hip (n = 651). Potential confounders controlled included: age, gender, family history of osteoporosis, physical activity, smoking, calcium intake, vitamin D status, estrogen status, medications, renal function, urine creatinine, body mass index, and change of body mass index. There were no associations between either urine pH or acid excretion and either the incidence of fractures or change of BMD after adjustment for confounders. Urine pH and urine acid excretion do not predict osteoporosis risk.

  10. Isomorphic red blood cells using automated urine flow cytometry is a reliable method in diagnosis of bladder cancer.

    PubMed

    Muto, Satoru; Sugiura, Syo-Ichiro; Nakajima, Akiko; Horiuchi, Akira; Inoue, Masahiro; Saito, Keisuke; Isotani, Shuji; Yamaguchi, Raizo; Ide, Hisamitsu; Horie, Shigeo

    2014-10-01

    We aimed to identify patients with a chief complaint of hematuria who could safely avoid unnecessary radiation and instrumentation in the diagnosis of bladder cancer (BC), using automated urine flow cytometry to detect isomorphic red blood cells (RBCs) in urine. We acquired urine samples from 134 patients over the age of 35 years with a chief complaint of hematuria and a positive urine occult blood test or microhematuria. The data were analyzed using the UF-1000i (®) (Sysmex Co., Ltd., Kobe, Japan) automated urine flow cytometer to determine RBC morphology, which was classified as isomorphic or dysmorphic. The patients were divided into two groups (BC versus non-BC) for statistical analysis. Multivariate logistic regression analysis was used to determine the predictive value of flow cytometry versus urine cytology, the bladder tumor antigen test, occult blood in urine test, and microhematuria test. BC was confirmed in 26 of 134 patients (19.4 %). The area under the curve for RBC count using the automated urine flow cytometer was 0.94, representing the highest reference value obtained in this study. Isomorphic RBCs were detected in all patients in the BC group. On multivariate logistic regression analysis, only isomorphic RBC morphology was significantly predictive for BC (p < 0.001). Analytical parameters such as sensitivity, specificity, positive predictive value, and negative predictive value of isomorphic RBCs in urine were 100.0, 91.7, 74.3, and 100.0 %, respectively. Detection of urinary isomorphic RBCs using automated urine flow cytometry is a reliable method in the diagnosis of BC with hematuria.

  11. Vasopressin, cortisol, and catecholamine concentrations in dogs with dilated cardiomyopathy.

    PubMed

    Tidholm, Anna; Häggström, Jens; Hansson, Kerstin

    2005-10-01

    To evaluate plasma concentrations and urinary excretion of vasopressin and cortisol and urinary excretion of catecholamines in dogs with dilated cardiomyopathy (DCM). 15 dogs with clinical signs of DCM, 15 dogs with preclinical DCM, and 15 control dogs. Physical examinations, thoracic radiography, ECG, and echocardiography were performed on all dogs. Blood and urine samples were collected. Plasma concentration of vasopressin and the urine cortisol-to-urine creatinine ratio were significantly increased in dogs with clinical signs of DCM and dogs with preclinical DCM, compared with control dogs. Plasma vasopressin concentration was significantly higher in dogs with clinical signs of DCM, compared with dogs with preclinical DCM. Urine vasopressin-to-urine creatinine ratio was significantly increased in dogs with clinical signs of DCM, compared with dogs with preclinical DCM and control dogs. Urine epinephrine-to-urine creatinine ratio and urine norepinephrine-to-urine creatinine ratio were significantly increased in dogs with clinical signs of DCM, compared with control dogs. Plasma concentration of cortisol and urine dopamine-to-urine creatinine ratio did not differ significantly among groups. According to this study, the neuroendocrine pattern is changed in dogs with preclinical DCM. These changes are even more pronounced in dogs with clinical signs of DCM. Analysis of concentrations of vasopressin, cortisol, and catecholamines may aid in identification of the clinical stages of DCM. These findings may also provide a basis for additional studies of the possible beneficial effects of vasopressin antagonists and beta-adrenergic receptor antagonists in the treatment of dogs with congestive heart failure and DCM.

  12. Detection of prostate cancer-specific transcripts in extracellular vesicles isolated from post-DRE urine.

    PubMed

    Pellegrini, Kathryn L; Patil, Dattatraya; Douglas, Kristen J S; Lee, Grace; Wehrmeyer, Kathryn; Torlak, Mersiha; Clark, Jeremy; Cooper, Colin S; Moreno, Carlos S; Sanda, Martin G

    2017-06-01

    The measurement of gene expression in post-digital rectal examination (DRE) urine specimens provides a non-invasive method to determine a patient's risk of prostate cancer. Many currently available assays use whole urine or cell pellets for the analysis of prostate cancer-associated genes, although the use of extracellular vesicles (EVs) has also recently been of interest. We investigated the expression of prostate-, kidney-, and bladder-specific transcripts and known prostate cancer biomarkers in urine EVs. Cell pellets and EVs were recovered from post-DRE urine specimens, with the total RNA yield and quality determined by Bioanalyzer. The levels of prostate, kidney, and bladder-associated transcripts in EVs were assessed by TaqMan qPCR and targeted sequencing. RNA was more consistently recovered from the urine EV specimens, with over 80% of the patients demonstrating higher RNA yields in the EV fraction as compared to urine cell pellets. The median EV RNA yield of 36.4 ng was significantly higher than the median urine cell pellet RNA yield of 4.8 ng. Analysis of the post-DRE urine EVs indicated that prostate-specific transcripts were more abundant than kidney- or bladder-specific transcripts. Additionally, patients with prostate cancer had significantly higher levels of the prostate cancer-associated genes PCA3 and ERG. Post-DRE urine EVs are a viable source of prostate-derived RNAs for biomarker discovery and prostate cancer status can be distinguished from analysis of these specimens. Continued analysis of urine EVs offers the potential discovery of novel biomarkers for pre-biopsy prostate cancer detection. © 2017 Wiley Periodicals, Inc.

  13. 78 FR 44965 - Notice of Temporary Closure and Temporary Restrictions of Specific Uses on Public Lands for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-25

    ... acid diethylamide: urine, 25 ng/ml; blood, 10 ng/ml (g) Marijuana: urine, 10 ng/ml; blood, 2 ng/ml (h) Marijuana metabolite: urine, 15 ng/ml; blood, 5 ng/ml (i) Methamphetamine: urine, 500 ng/ml; blood, 100 ng...

  14. Urine collection device

    NASA Technical Reports Server (NTRS)

    Michaud, R. B. (Inventor)

    1981-01-01

    A urine collection device for females is described. It is comprised of a collection element defining a urine collection chamber and an inlet opening into the chamber and is adapted to be disposed in surrounding relation to the urethral opening of the user. A drainage conduit is connected to the collection element in communication with the chamber whereby the chamber and conduit together comprise a urine flow pathway for carrying urine generally away from the inlet. A first body of wicking material is mounted adjacent the collection element and extends at least partially into the flow pathway. The device preferably also comprise a vaginal insert element including a seal portion for preventing the entry of urine into the vagina.

  15. The Utilization of Urine Processing for the Advancement of Life Support Technologies

    NASA Technical Reports Server (NTRS)

    Grossi-Soyster, Elysse; Hogan, John; Flynn, Michael

    2014-01-01

    The success of long-duration missions will depend on resource recovery and the self-sustainability of life support technologies. Current technologies used on the International Space Station (ISS) utilize chemical and mechanical processes, such as filtration, to recover potable water from urine produced by crewmembers. Such technologies have significantly reduced the need for water resupply through closed-loop resource recovery and recycling. Harvesting the important components of urine requires selectivity, whether through the use of membranes or other physical barriers, or by chemical or biological processes. Given the chemical composition of urine, the downstream benefits of urine processing for resource recovery will be critical for many aspects of life support, such as food production and the synthesis of biofuels. This paper discusses the beneficial components of urine and their potential applications, and the challenges associated with using urine for nutrient recycling for space application.

  16. The effect of anesthetization and urinary bladder catheterization on renal function of rainbow trout

    USGS Publications Warehouse

    Hunn, J.B.; Willford, W.A.

    1970-01-01

    1. Rainbow trout were anesthetized with MS-222 (Sandoz) or methylpentynol and catheterized. Urine was collected at selected intervals up to 48 hr. 2. Effects of MS-222 anesthesia on urine flow and composition were isolated from the stress of catheterization by re-anesthetizing the fish 18 to 20 hr post catheterization. 3. Urine output patterns were similar following MS-222 or methylpentynol anesthesia and catheterization. Highest urine flows were measured 4 to 8 hr post treatment. The highest urine output after re-anesthetization with MS-222 was observed 2 to 4 hr post-anesthesia. 4. Highest concentrations of Na2+, K+, Ca2+, Cl- and inorganic PO4 in the urine were measured in the first 2 hr after anesthesia and catheterization. 5. Flow rates and chemical composition of urine indicate that "normal" renal function is re-established 12 to 24 hr post-treatment.

  17. Substitution of human for horse urine disproves an accusation of doping*.

    PubMed

    Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo

    2008-09-01

    In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.

  18. Four-man rated dual catalyst system for the recovery of water from urine

    NASA Technical Reports Server (NTRS)

    Budininkas, P.

    1978-01-01

    The catalytic system was integrated with a 4-man rated urine wick evaporator. During operation, urine vapor produced by the wick-evaporator was treated in the catalytic system to remove ammonia and volatile hydrocarbons, and water was recovered by condensation in a water cooled condenser. The system operated completely automatically and required no manual adjustments, except periodic supply of urine and removal of the recovered water. Although the system was designed for treating 0.325 kg urine per hour, this rate could be achieved only with a fresh wick, then gradually decreased as the wick became saturated with urine solids. The average urine treatment rates achieved during each of the three endurance tests were 0.137, 0.217, and 0.235 kg/hr. The quality of the recovered water meets drinking water standards, with the exception of a generally low pH.

  19. Coca tea consumption causes positive urine cocaine assay.

    PubMed

    Mazor, Suzan S; Mycyk, Mark B; Wills, Brandon K; Brace, Larry D; Gussow, Leon; Erickson, Timothy

    2006-12-01

    Coca tea, derived from the same plant that is used to synthesize cocaine, is commonly consumed in South America and easily obtained in the United States. To determine whether consumption of coca tea would result in a positive urine toxicology screen for cocaine metabolites. Five healthy adult volunteers consumed coca tea and underwent serial quantitative urine testing for cocaine metabolites by fluorescence polarization immunoassay. The cutoff for a positive assay was chosen at 300 ng/ml, the National Institute on Drug Abuse standard. Each participant's urine cocaine assay was positive (level exceeding 300 ng/ml) by 2 h after ingestion. Three out of five participants' samples remained positive at 36 h. Mean urine benzoylecgonine concentrations in all postconsumption samples was 1777 ng/ml (95% confidence interval: 1060-2495). Coca tea ingestion resulted in a positive urine assay for cocaine metabolite. Healthcare professionals should consider a history of coca tea ingestion when interpreting urine toxicology results.

  20. Urinary incontinence

    MedlinePlus

    Loss of bladder control; Uncontrollable urination; Urination - uncontrollable; Incontinence - urinary ... have diabetes, keep your blood sugar under good control. For urine leaks, wear absorbent pads or undergarments. ...

  1. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...

  2. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...

  3. 9 CFR 311.37 - Odors, foreign and urine.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Odors, foreign and urine. 311.37..., foreign and urine. (a) Carcasses which give off a pronounced odor of medicinal, chemical, or other foreign substance shall be condemned. (b) Carcasses which give off a pronounced urine odor shall be condemned. (c...

  4. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...

  5. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  6. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  7. 9 CFR 311.37 - Odors, foreign and urine.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Odors, foreign and urine. 311.37..., foreign and urine. (a) Carcasses which give off a pronounced odor of medicinal, chemical, or other foreign substance shall be condemned. (b) Carcasses which give off a pronounced urine odor shall be condemned. (c...

  8. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...

  9. 9 CFR 311.37 - Odors, foreign and urine.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Odors, foreign and urine. 311.37..., foreign and urine. (a) Carcasses which give off a pronounced odor of medicinal, chemical, or other foreign substance shall be condemned. (b) Carcasses which give off a pronounced urine odor shall be condemned. (c...

  10. 9 CFR 311.37 - Odors, foreign and urine.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Odors, foreign and urine. 311.37..., foreign and urine. (a) Carcasses which give off a pronounced odor of medicinal, chemical, or other foreign substance shall be condemned. (b) Carcasses which give off a pronounced urine odor shall be condemned. (c...

  11. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  12. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  13. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...

  14. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  15. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  16. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  17. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  18. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  19. Determination of uromodulin in human urine: influence of storage and processing.

    PubMed

    Youhanna, Sonia; Weber, Julien; Beaujean, Viviane; Glaudemans, Bob; Sobek, Jens; Devuyst, Olivier

    2014-01-01

    Uromodulin (Tamm-Horsfall protein) is the most abundant protein excreted in the urine under physiological conditions. It is exclusively produced in the kidney and secreted into the urine via proteolytic cleavage. The involvement of UMOD, the gene that encodes uromodulin, in rare autosomal dominant diseases, and its robust genome-wide association with the risk of chronic kidney disease suggest that the level of uromodulin in urine could represent a critical biomarker for kidney function. The structure of uromodulin is complex, with multiple disulfide bonds and typical domains of extracellular proteins. Thus far, the conditions influencing stability and measurement of uromodulin in human urine have not been systematically investigated, giving inconsistent results. In this study, we used a robust, in-house ELISA to characterize the conditions of sampling and storage necessary to provide a faithful dosage of uromodulin in the urine. The levels of uromodulin in human urine were significantly affected by centrifugation and vortexing, as well as by the conditions and duration of storage. These results validate a simple, low-cost ELISA and document the optimal conditions of processing and storage for measuring uromodulin in human urine.

  20. The void in using urine concentration to assess population fluid intake adequacy or hydration status.

    PubMed

    Cheuvront, Samuel N; Muñoz, Colleen X; Kenefick, Robert W

    2016-09-01

    Urine concentration can be used to assess fluid intake adequacy or to diagnose dehydration. However, too often urine concentration is used inappropriately to draw dubious conclusions that could have harmful health and economic consequences. Inappropriate uses of urine concentration relate primarily to convenience sampling (timing) and problems related to convenience sampling (misapplication of thresholds), but a conceptual problem also exists with using urine concentration in isolation. The purpose of this Perspective article is to briefly explain the problematic nature of current practices and to offer a possible solution to improve practice with minimal added complication. When urine is used exclusively to assess fluid intake adequacy and hydration status in adults, we propose that only when urine concentration is high (>850 mmol/kg) and urine excretion rate is low (<850 mL/24 h) should suspicion of inadequate drinking or impending dehydration be considered. Prospective tests of the 850 × 850 thresholds will provide supporting evidence and/or help refine the best thresholds for men and women, young and old. © 2016 American Society for Nutrition.

  1. Determination of Lead in Urine by Atomic Absorption Spectrophotometry1

    PubMed Central

    Selander, Stig; Cramé, Kim

    1968-01-01

    A method for the determination of lead in urine by means of atomic absorption spectrophotometry (AAS) is described. A combination of wet ashing and extraction with ammonium pyrrolidine dithiocarbamate into isobutylmethylketone was used. The sensitivity was about 0·02 μg./ml. for 1% absorption, and the detection limit was about 0·02 μg./ml. with an instrumental setting convenient for routine analyses of urines. Using the scale expansion technique, the detection limit was below 0·01 μg./ml., but it was found easier to determine urinary lead concentrations below 0·05 μg./ml. by concentrating the lead in the organic solvent by increasing the volume of urine or decreasing that of the solvent. The method was applied to fresh urines, stored urines, and to urines, obtained during treatment with chelating agents, of patients with lead poisoning. Urines with added inorganic lead were not used. The results agreed well with those obtained with a colorimetric dithizone extraction method (r = 0·989). The AAS method is somewhat more simple and allows the determination of smaller lead concentrations. PMID:5647975

  2. Effects of Hydration and Calcium Supplementation on Urine Calcium Concentration in Healthy Postmenopausal Women.

    PubMed

    Harris, Susan S; Dawson-Hughes, Bess

    2015-01-01

    The aim of this study was to determine whether calcium supplementation, compared with placebo, increases urine calcium concentrations to levels indicative of increased renal stone risk, and the role that fluid intake, as indicated by urine volume, may play in mitigating this risk. This is a secondary analysis of data from a randomized placebo-controlled trial of 500 mg/d calcium supplementation to prevent bone loss. Subjects were 240 white postmenopausal women age 40 to 70 years in good general health. Effects of supplementation on 1-year changes in 24h urine calcium concentration and urine volume were examined. Both treatment group and urine volume were strong independent predictors of urine calcium concentration (p < 0.001). Among subjects with urine volume under 2 L/24 h, more than half of placebo subjects were at lowest risk for renal stones compared with less than 35% of calcium-supplemented subjects. Among those with higher urine volumes, all placebo subjects and more than 80% of calcium supplemented subjects were at lowest risk. The increased risk of renal stones with calcium supplement use may be largely eliminated with adequate fluid intake, but older adults may not spontaneously consume adequate fluids to minimize this risk and should be counseled to do so.

  3. Albumin adsorption onto surfaces of urine collection and analysis containers☆

    PubMed Central

    Robinson, Mary K.; Caudill, Samuel P.; Koch, David D.; Ritchie, James; Hortin, Glen; Eckfeldt, John H.; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W. Greg

    2017-01-01

    Background Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods We added 125I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results Adsorption of urine albumin (UA) at 5–6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH 8 than pH 5 but only 3 cases had p <0.05. Adsorption from 11 unaltered urine samples with albumin 5–333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2 l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2–28%) was larger than that from urine. Conclusions Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. PMID:24513540

  4. Albumin adsorption onto surfaces of urine collection and analysis containers.

    PubMed

    Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg

    2014-04-20

    Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    PubMed

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  6. Non-invasive optical detection of esophagus cancer based on urine surface-enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Huang, Shaohua; Wang, Lan; Chen, Weiwei; Lin, Duo; Huang, Lingling; Wu, Shanshan; Feng, Shangyuan; Chen, Rong

    2014-09-01

    A surface-enhanced Raman spectroscopy (SERS) approach was utilized for urine biochemical analysis with the aim to develop a label-free and non-invasive optical diagnostic method for esophagus cancer detection. SERS spectrums were acquired from 31 normal urine samples and 47 malignant esophagus cancer (EC) urine samples. Tentative assignments of urine SERS bands demonstrated esophagus cancer specific changes, including an increase in the relative amounts of urea and a decrease in the percentage of uric acid in the urine of normal compared with EC. The empirical algorithm integrated with linear discriminant analysis (LDA) were employed to identify some important urine SERS bands for differentiation between healthy subjects and EC urine. The empirical diagnostic approach based on the ratio of the SERS peak intensity at 527 to 1002 cm-1 and 725 to 1002 cm-1 coupled with LDA yielded a diagnostic sensitivity of 72.3% and specificity of 96.8%, respectively. The area under the receive operating characteristic (ROC) curve was 0.954, which further evaluate the performance of the diagnostic algorithm based on the ratio of the SERS peak intensity combined with LDA analysis. This work demonstrated that the urine SERS spectra associated with empirical algorithm has potential for noninvasive diagnosis of esophagus cancer.

  7. Urine Collected From Diapers Can Be Used for 2-Dimensional Polyacrylamide Gel Electrophoresis (2D-PAGE) in Infants and Young Children

    PubMed Central

    Kennedy, Mary Jayne; Griffin, Angela; Su, Ruifeng; Merchant, Michael; Klein, Jon

    2011-01-01

    Urinary proteomic profiling has potential to identify candidate biomarkers of renal injury in infants provided an adequate urine sample can be obtained. Although diapers are used to obtain urine for clinical evaluation, their use for proteomic analysis has not been investigated. We therefore performed feasibility studies on the use of diaper-extracted urine for 2-dimensional polyacrylamide gel electrophoresis (2D-PAGE). Pediatric waste urine (2–20 mL) was applied to gel-containing, non-gel and cotton-gauze diapers and then mechanically expressed. Urine volume and total protein were measured pre- and post-extraction. Proteins were separated via 2D-PAGE following application of urine (20–40 mL) to each matrix. 2D-PAGE was also performed on clinical specimens collected using each diaper type. Differences in the adsorption and retention of urine volume and protein were noted between matrices. Non-gel and cotton-gauze diapers provided the best protein/volume recovery and the lowest interference with the Bradford assay. 2D-PAGE was also successfully completed using urine samples from both cotton fiber matrices. Conversely, samples from low-gel diapers demonstrated poor protein separation and reproducibility. Diapers containing cotton-fiber matrices appear adequate for 2D-PAGE. Qualitative and quantitative analyses of resolved proteins using replicate, high resolution gels will be required, however, before diaper-extracted urine can be applied in proteomic profiling. PMID:21137001

  8. Mean population salt intake estimated from 24-h urine samples and spot urine samples: a systematic review and meta-analysis.

    PubMed

    Huang, Liping; Crino, Michelle; Wu, Jason H Y; Woodward, Mark; Barzi, Federica; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Neal, Bruce

    2016-02-01

    Estimating equations based on spot urine samples have been identified as a possible alternative approach to 24-h urine collections for determining mean population salt intake. This review compares estimates of mean population salt intake based upon spot and 24-h urine samples. We systematically searched for all studies that reported estimates of daily salt intake based upon both spot and 24-h urine samples for the same population. The associations between the two were quantified and compared overall and in subsets of studies. A total of 538 records were identified, 108 were assessed as full text and 29 were included. The included studies involved 10,414 participants from 34 countries and made 71 comparisons available for the primary analysis. Overall average population salt intake estimated from 24-h urine samples was 9.3 g/day compared with 9.0 g/day estimated from the spot urine samples. Estimates based upon spot urine samples had excellent sensitivity (97%) and specificity (100%) at classifying mean population salt intake as above or below the World Health Organization maximum target of 5 g/day. Compared with the 24-h samples, estimates based upon spot urine overestimated intake at lower levels of consumption and underestimated intake at higher levels of consumption. Estimates of mean population salt intake based upon spot urine samples can provide countries with a good indication of mean population salt intake and whether action on salt consumption is required. Published by Oxford University Press on behalf of the International Epidemiological Association 2015. This work is written by US Government employees and is in the public domain in the US.

  9. [Validity of the assessment of urinary protein excretion by spot urine in patients with chronic kidney disease].

    PubMed

    Hayashi, Ami; Okada, Tomonari; Matsumoto, Hiroshi; Nagaoka, Yume; Wada, Toshikazu; Gondo, Asako; Nango, Tomoka; Miyaoka, Yoshitaka; Watanabe, Kanna; Iwata, Azusa; Nakao, Toshiyuki

    2013-01-01

    We investigate the validity of the assessment of urinary protein excretion by spot urine samples collected by different methods in outpatients with chronic kidney disease (CKD). SUBJECTS AND METHODS We obtained 24-hour urine and two spot urine samples, including the first morning urine and daytime urine in 159 CKD patients. Urinary protein excretion was assessed by the protein/creatinine ratio from spot urine samples (morning: m-UP (g/gCr), daytime: d-UP (g/gCr) ]. We examined the correlations and the differences among m-UP, d-UP and the actual urinary protein excretion obtained by 24-hour urine (a-UP(g/day) . Significant correlations were found between m-UP and a-UP, and between d-UP and a-UP (r = 0.88, 0.85; p < 0.001). Correlations between m-UP and a-UP were greater relative to those between d-UP and a-UP in patients with less than 3.5 g/day of a-UP and in patients with CKD stages 1 to approximately 3. The percent difference between m-UP and a-UP was--16.0 +/- 40.5%, and that between d-UP and a-UP was 27.1 +/- 72.9%. The absolute value of the percent difference between d-UP and a-UP tended to be greater than that between m-UP and a-UP (34.9 +/- 25.9% vs. 49.9 +/- 59.9%, p = 0.06). Urinary protein/creatinie ratio of the first morning urine is better approximate the urinary protein excretion obtained by 24-hour urine compared with that of spot urine in the daytime.

  10. [Effect of tobacco smoking on albumin concentration and β-glucuronidase activity in urine of smelters].

    PubMed

    Bizonń, Anna; Witt, Katarzyna; Milnerowicz, Malgorzata; Milnerowicz, Halina

    2014-01-01

    The aim of present study was to estimate the nephrotoxicity of occupational exposure to heavy metals on albumin concentration and β-glucuronidase activity in the urine of smoking and non-smoking smelters. The study was performed in urine of 101 smoking and non-smoking smelters as well as 65 smoking and non-smoking male subjects unexposed to heavy metals. Section into smoking and non-smoking groups was made on basis on direct personal interview and by determination of serum cotinine concentration. The concentration of albumin in urine was measured with commercial test (Micro-Albumin ELISA Cat. No 5MA 74212, ORGENTEC Diagnostika Gmbh, Germany). The activity of β-glucuronidase in urine were determined in urine using 4-nitrophenyl β D-glucuronide (Cat. No 73677, Sigma Aldrich, Germany) as a substrate. We have observed higher albumin concentration and β-glucuronidase activity in urine of smoking and non-smoking smelters when compared to control groups. We have also found the influence of tobacco smoke as well as amount of cigarettes smoked on albumin concentration in urine of smoking smelters. A statistically significant difference was detected between activity of β-glucuronidase in urine of smoking and non-smoking smelters, which suggest as additional negative factor of exposure to tobacco smoke. Analyzing the impact of smoking intensity we have found higher albumin concentration and β-glucuronidase activity in urine of smelters smoking ≥20 cigarettes per day when compared to smelters smoking <20 cigarettes per day. The elevation of albumin concentration and β-glucuronidase activity in urine of workers occupational exposure to heavy metals and tobacco smoke indicated, that environmental exposure on these factors can disorders kidney functions.

  11. Effect of urine creatinine level during pregnancy on dipstick test.

    PubMed

    Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori

    2017-06-01

    Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.

  12. Microbial ureolysis in the seawater-catalysed urine phosphorus recovery system: Kinetic study and reactor verification.

    PubMed

    Tang, Wen-Tao; Dai, Ji; Liu, Rulong; Chen, Guang-Hao

    2015-12-15

    Our previous study has confirmed the feasibility of using seawater as an economical precipitant for urine phosphorus (P) precipitation. However, we still understand very little about the ureolysis in the Seawater-based Urine Phosphorus Recovery (SUPR) system despite its being a crucial step for urine P recovery. In this study, batch experiments were conducted to investigate the kinetics of microbial ureolysis in the seawater-urine system. Indigenous bacteria from urine and seawater exhibited relatively low ureolytic activity, but they adapted quickly to the urine-seawater mixture during batch cultivation. During cultivation, both the abundance and specific ureolysis rate of the indigenous bacteria were greatly enhanced as confirmed by a biomass-dependent Michaelis-Menten model. The period for fully ureolysis was decreased from 180 h to 2.5 h after four cycles of cultivation. Based on the successful cultivation, a lab-scale SUPR reactor was set up to verify the fast ureolysis and efficient P recovery in the SUPR system. Nearly complete urine P removal was achieved in the reactor in 6 h without adding any chemicals. Terminal Restriction Fragment Length Polymorphism (TRFLP) analysis revealed that the predominant groups of bacteria in the SUPR reactor likely originated from seawater rather than urine. Moreover, batch tests confirmed the high ureolysis rates and high phosphorus removal efficiency induced by cultivated bacteria in the SUPR reactor under seawater-to-urine mixing ratios ranging from 1:1 to 9:1. This study has proved that the enrichment of indigenous bacteria in the SUPR system can lead to sufficient ureolytic activity for phosphate precipitation, thus providing an efficient and economical method for urine P recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Measurements of C-reactive protein (CRP) and nerve-growth-factor (NGF) concentrations in serum and urine samples of dogs with neurologic disorders.

    PubMed

    Kordass, Ulrike; Carlson, Regina; Stein, Veronika Maria; Tipold, Andrea

    2016-01-08

    The purpose of this study was to prove the hypothesis that C-reactive protein (CRP) and nerve growth factor (NGF) may be potential biomarkers for lower urinary tract disorders and may be able to distinguish between micturition dysfunctions of different origin in dogs with spinal cord diseases. NGF- and CRP- concentrations were measured in serum and urine samples using specific ELISA-Kits. Results in urine were standardized by urine-creatinine levels. CRP in serum was detectable in 32/76 and in urine samples in 40/76 patients. NGF could be measured in all serum and in 70/76 urine samples. Urinary CRP concentrations were significantly higher in dogs with micturition dysfunction (p = 0.0009) and in dogs with different neurological diseases (p = 0.0020) compared to the control group. However, comparing dogs with spinal cord disorders with and without associated micturition dysfunction no significant difference could be detected for NGF and CRP values in urine or serum samples. Additionally, levels did not decrease significantly, when measured at the time when the dogs regained the ability to urinate properly (urinary NGF p = 0.7962; urinary CRP p = 0.078). Urine samples with bacteria and/or leukocytes had no significant increase in urinary NGF (p = 0.1112) or CRP (p = 0.0534) concentrations, but higher CRP-levels in urine from dogs with cystitis were found compared to dogs without signs of cystitis. From these data we conclude that neither CRP nor NGF in urine or serum can be considered as reliable biomarkers for micturition disorders in dogs with spinal cord disorders in a clinical setting, but their production might be part of the pathogenesis of such disorders. Significantly higher levels of CRP could be found in the urine of dogs with micturition dysfunctions compared to control dogs. This phenomenon could potentially be explained by unspecific extrahepatic CRP production by smooth muscle cells in the dilated bladder.

  14. Hydration, Fluid Intake, and Related Urine Biomarkers among Male College Students in Cangzhou, China: A Cross-Sectional Study-Applications for Assessing Fluid Intake and Adequate Water Intake.

    PubMed

    Zhang, Na; Du, Songming; Tang, Zhenchuang; Zheng, Mengqi; Yan, Ruixia; Zhu, Yitang; Ma, Guansheng

    2017-05-11

    The objectives of this study were to assess the associations between fluid intake and urine biomarkers and to determine daily total fluid intake for assessing hydration status for male college students. A total of 68 male college students aged 18-25 years recruited from Cangzhou, China completed a 7-day cross-sectional study. From day 1 to day 7; all subjects were asked to complete a self-administered 7-day 24-h fluid intake record. The foods eaten by subjects were weighed and 24-h urine was collected for three consecutive days on the last three consecutive days. On the sixth day, urine osmolality, specific gravity (USG), pH, and concentrations of potassium, sodium, and chloride was determined. Subjects were divided into optimal hydration, middle hydration, and hypohydration groups according to their 24-h urine osmolality. Strong relationships were found between daily total fluid intake and 24-h urine biomarkers, especially for 24-h urine volume ( r = 0.76; p < 0.0001) and osmolality ( r = 0.76; p < 0.0001). The percentage of the variances in daily total fluid intake ( R ²) explained by PLS (partial least squares) model with seven urinary biomarkers was 68.9%; two urine biomarkers-24-h urine volume and osmolality-were identified as possible key predictors. The daily total fluid intake for assessing optimal hydration was 2582 mL, while the daily total fluid intake for assessing hypohydration was 2502 mL. Differences in fluid intake and urine biomarkers were found among male college students with different hydration status. A strong relationship existed between urine biomarkers and fluid intake. A PLS model identified that key variables for assessing daily total fluid intake were 24-h urine volume and osmolality. It was feasibility to use total fluid intake to judge hydration status.

  15. Development of an In-line Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Branelle R.

    2009-01-01

    Exposure to microgravity during space flight causes bone loss when calcium and other metabolic by-products are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is thus essential in determining crew bone loss and the effectiveness of the countermeasures that are taken to minimize this loss. Earlier space shuttle Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to the cross-contamination that took place between users, as well as to fluid system instabilities. Crew urine voids are currently collected manually in a flexible plastic bag that contains a known tracer quantity. A crew member must completely mix the contents of this bag before withdrawing a representative syringe sample for later ground analysis. The existing bag system accuracy is therefore highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures void volume, and allows for syringe sampling. After the ISS UMS has been used by a crew member, it delivers urine to the WHC for normal processing. The UMS plumbing is then flushed with a small volume of water. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, consequently greatly reducing cross-contamination among urine voids (less than 0.5 mL urine) while also providing accurate volume measurements (less than 2 percent error for 100 to 1,000 mL void volumes). ISS UMS performance has been validated through extensive ground tests and reduced-gravity aircraft flights. The locker-sized ISS UMS is currently undergoing a design modification that will permit it to interface with the ISS Node 3 WHC Russian toilet (ACY) hardware. The operating principles, characteristics, and results of this design modification are outlined here.

  16. Retrograde contamination and practical handling of urine-meters: a comparison of three systems for the measurement of hourly diuresis in an experimental bladder-drainage model and in clinical use.

    PubMed

    Rasmussen, A; Frimodt-Møller, N; Espersen, F; Roed, M; Frimodt-Møller, C

    1996-08-01

    To compare three different urine metering systems for their ability to prevent retrograde contamination in an in vitro model of a closed urinary drainage system and for qualities important to their practical handling in a clinical setting. Using three urine-meters (the Braun Ureofix 511, the Kendall Curity 4000 and the Unoplast Unometer 500) the in vitro model was constantly flushed with a solution of Mueller-Hinton broth diluted with saline. On the first day, the urine collecting bag was inoculated with 10(8) cells of Pseudomonas aeruginosa. The system was operated for 12 days with daily sampling of the model bladder to detect any contamination. After 12 days the experiment was stopped and sampling performed at various locations, including the urine-meter and the tubing. Nine of each type of urine-meter were tested, i.e. three in three different experiments. In the clinical study, 45 patients were randomized to each of the three urine-meters and the nurses attending them were asked to complete a questionnaire on the practical handling of the urine-meters. When the urine-meters was omitted from the model system, the 'bladder' became contaminated with the test bacteria within 3 days. None of the nine Unometer 500 systems became contaminated, compared with four of each of the other two systems (P < 0.05). In clinical use, the Unometer 500 and Ureofix 511 were easier to suspend and empty than was the Curity 4000. The Unometer 500 was significantly easier to handle when the collecting bag was emptied. Urine-meters can prevent retrograde contamination in a closed bladder-drainage model, but the degree of prevention depends upon the type of urine-meter. In daily practice, there were differences in the ease of suspension of the systems and in the emptying of the urine-meter and collecting bag.

  17. Detection of depleted uranium in urine of veterans from the 1991 Gulf War.

    PubMed

    Gwiazda, R H; Squibb, K; McDiarmid, M; Smith, D

    2004-01-01

    American soldiers involved in "friendly fire" accidents during the 1991 Gulf War were injured with depleted-uranium-containing fragments or possibly exposed to depleted uranium via other routes such as inhalation, ingestion, and/or wound contamination. To evaluate the presence of depleted uranium in these soldiers eight years later, the uranium concentration and depleted uranium content of urine samples were determined by inductively coupled plasma mass spectrometry in (a) depleted uranium exposed soldiers with embedded shrapnel, (b) depleted uranium exposed soldiers with no shrapnel, and (c) a reference group of deployed soldiers not involved in the friendly fire incidents. Uranium isotopic ratios measured in many urine samples injected directly into the inductively coupled plasma mass spectrometer and analyzed at a mass resolution m/delta m of 300 appeared enriched in 235U with respect to natural abundance (0.72%) due to the presence of an interference of a polyatomic molecule of mass 234.81 amu that was resolved at a mass resolution m/delta m of 4,000. The 235U abundance measured on uranium separated from these urines by anion exchange chromatography was clearly natural or depleted. Urine uranium concentrations of soldiers with shrapnel were higher than those of the two other groups, and 16 out of 17 soldiers with shrapnel had detectable depleted uranium in their urine. In depleted uranium exposed soldiers with no shrapnel, depleted uranium was detected in urine samples of 10 out of 28 soldiers. The median uranium concentration of urines with depleted uranium from soldiers without shrapnel was significantly higher than in urines with no depleted uranium, though substantial overlap in urine uranium concentrations existed between the two groups. Accordingly, assessment of depleted uranium exposure using urine must rely on uranium isotopic analyses, since urine uranium concentration is not an unequivocal indicator of depleted uranium presence in soldiers with no embedded shrapnel.

  18. Analysis of urobilinogen and urine bilirubin for intra-abdominal injury in blunt trauma patients.

    PubMed

    Gorchynski, Julie; Dean, Kevin; Anderson, Craig L

    2009-05-01

    To determine the point prevalence of urine bilirubin, urine hemoglobin and urobilinogen in blunt trauma patients, and to evaluate its utility as a screening tool for intra-abdominal injury. Data analysis of 986 consecutive trauma patients of which 698 were adult blunt trauma patients. Five-hundred sixteen subjects had a urinalysis and a CT scan of the abdomen/pelvis or exploratory laparotomy. We reviewed initial urinalysis results from trauma patients in the emergency department (ED) for the presence of urine hemoglobin, uroblinogen and urine bilirubin. Computed tomography (CT) scan results and operative reports were reviewed from the trauma registry for evidence of liver laceration, spleen laceration, bowel or mesenteric injuries. There were 73 injuries and 57/516 patients (11%) with intra-abdominal injury. Urinalysis was positive for urobilinogen in 28/516 (5.4%) patients, urine bilirubin in 15/516 (2.9%) patients and urine hemoglobin in 313/516 (61%) patients. Nineteen/forty-seven (4%) subjects had liver lacerations, 28/56 (5%) splenic lacerations, and 15/5 (3%) bowel or mesenteric injury. Comparing the proportion of patients that had urobilinogen detected in the group with and without intra-abdominal injury, 8/28 (29%) subjects with urobilinogen, 5/15 (33%) subjects with bilirubin and 47/313 (15%) subjects with urine hemoglobin were found to have liver lacerations, spleen lacerations, or bowel/mesenteric injuries. Preexisting liver or biliary conditions were not statistically associated with elevation of urine bilirubin, urine hemoglobin or urobilinogen on initial urinalysis after blunt abdominal trauma. Point prevalence for urobilinogen, urine bilirubin and urine hemoglobin are 5.43% (28/516), 2.91% (15/516) and 60.7% (313/516) respectively. The utility of the initial routine urinalysis in the ED for adult blunt abdominal trauma patients should not be used as a screening tool for the evaluation of intra-abdominal injury.

  19. Comparison of Plasma and Urine Biomarker Performance in Acute Kidney Injury

    PubMed Central

    Schley, Gunnar; Köberle, Carmen; Manuilova, Ekaterina; Rutz, Sandra; Forster, Christian; Weyand, Michael; Formentini, Ivan; Kientsch-Engel, Rosemarie; Eckardt, Kai-Uwe; Willam, Carsten

    2015-01-01

    Background New renal biomarkers measured in urine promise to increase specificity for risk stratification and early diagnosis of acute kidney injury (AKI) but concomitantly may be altered by urine concentration effects and chronic renal insufficiency. This study therefore directly compared the performance of AKI biomarkers in urine and plasma. Methods This single-center, prospective cohort study included 110 unselected adults undergoing cardiac surgery with cardiopulmonary bypass between 2009 and 2010. Plasma and/or urine concentrations of creatinine, cystatin C, neutrophil gelatinase-associated lipocalin (NGAL), liver fatty acid-binding protein (L-FABP), kidney injury molecule 1 (KIM1), and albumin as well as 15 additional biomarkers in plasma and urine were measured during the perioperative period. The primary outcome was AKI defined by AKIN serum creatinine criteria within 72 hours after surgery. Results Biomarkers in plasma showed markedly better discriminative performance for preoperative risk stratification and early postoperative (within 24h after surgery) detection of AKI than urine biomarkers. Discriminative power of urine biomarkers improved when concentrations were normalized to urinary creatinine, but urine biomarkers had still lower AUC values than plasma biomarkers. Best diagnostic performance 4h after surgery had plasma NGAL (AUC 0.83), cystatin C (0.76), MIG (0.74), and L-FAPB (0.73). Combinations of multiple biomarkers did not improve their diagnostic power. Preoperative clinical scoring systems (EuroSCORE and Cleveland Clinic Foundation Score) predicted the risk for AKI (AUC 0.76 and 0.71) and were not inferior to biomarkers. Preexisting chronic kidney disease limited the diagnostic performance of both plasma and urine biomarkers. Conclusions In our cohort plasma biomarkers had higher discriminative power for risk stratification and early diagnosis of AKI than urine biomarkers. For preoperative risk stratification of AKI clinical models showed similar discriminative performance to biomarkers. The discriminative performance of both plasma and urine biomarkers was reduced by preexisting chronic kidney disease. PMID:26669323

  20. The urine output definition of acute kidney injury is too liberal

    PubMed Central

    2013-01-01

    Introduction The urine output criterion of 0.5 ml/kg/hour for 6 hours for acute kidney injury (AKI) has not been prospectively validated. Urine output criteria for AKI (AKIUO) as predictors of in-hospital mortality or dialysis need were compared. Methods All admissions to a general ICU were prospectively screened for 12 months and hourly urine output analysed in collection intervals between 1 and 12 hours. Prediction of the composite of mortality or dialysis by urine output was analysed in increments of 0.1 ml/kg/hour from 0.1 to 1 ml/kg/hour and the optimal threshold for each collection interval determined. AKICr was defined as an increase in plasma creatinine ≥26.5 μmol/l within 48 hours or ≥50% from baseline. Results Of 725 admissions, 72% had either AKICr or AKIUO or both. AKIUO (33.7%) alone was more frequent than AKICr (11.0%) alone (P <0.0001). A 6-hour urine output collection threshold of 0.3 ml/kg/hour was associated with a stepped increase in in-hospital mortality or dialysis (from 10% above to 30% less than 0.3 ml/kg/hour). Hazard ratios for in-hospital mortality and 1-year mortality were 2.25 (1.40 to 3.61) and 2.15 (1.47 to 3.15) respectively after adjustment for age, body weight, severity of illness, fluid balance, and vasopressor use. In contrast, after adjustment AKIUO was not associated with in-hospital mortality or 1-year mortality. The optimal urine output threshold was linearly related to duration of urine collection (r2 = 0.93). Conclusions A 6-hour urine output threshold of 0.3 ml/kg/hour best associated with mortality and dialysis, and was independently predictive of both hospital mortality and 1-year mortality. This suggests that the current AKI urine output definition is too liberally defined. Shorter urine collection intervals may be used to define AKI using lower urine output thresholds. PMID:23787055

  1. Quantification of chromatographic effects of vitamin B supplementation in urine and implications for hydration assessment.

    PubMed

    Kenefick, Robert W; Heavens, K R; Dennis, W E; Caruso, E M; Guerriere, K I; Charkoudian, N; Cheuvront, S N

    2015-07-15

    Changes in body water elicit reflex adjustments at the kidney, thus maintaining fluid volume homeostasis. These renal adjustments change the concentration and color of urine, variables that can, in turn, be used as biomarkers of hydration status. It has been suggested that vitamin supplementation alters urine color; it is unclear whether any such alteration would confound hydration assessment via colorimetric evaluation. We tested the hypothesis that overnight vitamin B2 and/or B12 supplementation alters urine color as a marker of hydration status. Thirty healthy volunteers were monitored during a 3-day euhydrated baseline, confirmed via first morning nude body mass, urine specific gravity, and urine osmolality. Volunteers then randomly received B2 (n = 10), B12 (n = 10), or B2 + B12 (n = 10) at ∼200 × recommended dietary allowance. Euhydration was verified on trial days (two of the following: body mass ± 1.0% of the mean of visits 1-3, urine specific gravity < 1.02, urine osmolality < 700 mmol/kg). Vitamin purity and urinary B2 concentration ([B2]) and [B12] were quantified via ultraperformance liquid chromatography. Two independent observers assessed urine color using an eight-point standardized color chart. Following supplementation, urinary [B2] was elevated; however, urine color was not different between nonsupplemented and supplemented trials. For example, in the B2 trial, urinary [B2] increased from 8.6 × 10(4) ± 7.7 × 10(4) to 5.7 × 10(6) ± 5.3 × 10(6) nmol/l (P < 0.05), and urine color went from 4 ± 1 to 5 ± 1 (P > 0.05). Both conditions met the euhydrated color classification. We conclude that a large overnight dose of vitamins B2 and B12 does not confound assessment of euhydrated status via urine color. Copyright © 2015 the American Physiological Society.

  2. Comparison of Human Papillomavirus Detections in Urine, Vulvar, and Cervical Samples from Women Attending a Colposcopy Clinic

    PubMed Central

    Gravitt, Patti E.; Dunn, S. Terence; Brown, David; Allen, Richard A.; Eby, Yolanda J.; Smith, Katie; Zuna, Rosemary E.; Zhang, Roy R.; Gold, Michael A.; Schiffman, Mark; Walker, Joan L.; Castle, Philip E.; Wentzensen, Nicolas

    2014-01-01

    While urine-based sampling for human papillomavirus (HPV) is being explored as a simple and noninvasive approach for cervical cancer screening, data comparing HPV genotyping in urine and those in cellular sampling of the cervix and vulva, and their correlation with rigorously confirmed cervical disease status, are sparse. We performed HPV genotyping on voided-urine and clinician-collected vulvar and cervical samples from 72 women undergoing colposcopy. Although urine-based HPV carcinogenic HPV detection was lower (58.3%) than cervical (73.6%) and vulvar (72.1%) detection (P = 0.05 and 0.07, respectively), the agreement of urine HPV with cervical and vulvar HPV was moderate (kappa = 0.55) and substantial (kappa = 0.62), respectively. Urine-based carcinogenic HPV detection had a clinical sensitivity of 80.8% (95% confidence interval [CI] = 60.7 to 93.5) and a specificity of 53.3% (95% CI = 37.9 to 68.3) for diagnosing cervical intraepithelial neoplasia grades 2/3 (CIN2/3) on histology; 90.0% of CIN3 was positive for urine HPV. The corresponding sensitivity and specificity values for vulvar sampling were 92% (95% CI = 74 to 99) and 40.5% (95% CI = 25.6 to 56.7), and those for cervical sampling were 96.2% (95% CI = 80.4 to 99.9) and 40% (95% CI = 25.7 to 55.7), respectively. HPV16 was the most common carcinogenic genotype detectable in 25% of urine, 33.8% of vulvar, and 31.9% of cervical samples overall, with prevalence increasing with cervical disease grade, regardless of the sampling method. Stronger cervical HPV PCR signal strengths were associated with increased frequency of urine HPV detection. In summary, the relatively lower detection rates but comparable clinical performance of urine-based HPV sampling underscore the need for larger studies to evaluate urine-based sampling for cervical cancer screening, epidemiologic studies, and postvaccination HPV disease surveillance. PMID:24197879

  3. Noninvasive and Painless Urine Glucose Detection by Using Computer-based Polarimeter

    NASA Astrophysics Data System (ADS)

    Sutrisno; Laksono, Y. A.; Hidayat, N.

    2017-05-01

    Diabetes kills millions of people worldwide each year. It challenges us as researchers to give contribution in early diagnosis to ensure a healthy life. As a matter of fact, common glucose testing devices that have been widely used so far are, at least, glucose meter and urine glucose test strip. The glucose meter ordinarily requires blood taken from patient’s finger. The glucose test strip uses patient’s urine but records unspecific urine glucose level, since the strip only provides the glucose level in some particular ranges. Instead of detecting the glucose level in blood and using the non-specific technique, a noninvasive and painless technique that can detect glucose level accurately will provide a more feasible approach for diabetes diagnosis. The noninvasive and painless urine glucose level monitoring by means of computer-based polarimeter is presented in this paper. The instrument consisted of a power source, a sample box, a light sensor, a polarizer, an analyzer, an analog to digital converter (ADC), and a computer. The concentration of urine glucose concentration was evaluated from the curve of the change in detected optical rotation angle and output potential by the computer-based polarimeter. Statistical analyses by means of Gaussian fitting and linear regression were applied to investigate the rotation angle and urine glucose concentration, respectively. From our experiment, the urine glucose level, measured by glucose test strips, of the normal patient was 100 mg/dl, and the diabetic patient was 500 mg/dl. Our polarimeter even read more precise values for the urine glucose concentrations of those normal and diabetic of the same patients, i.e. 50.61 mg/dl and 502.41 mg/dl, respectively. In other words, the results showed that our polarimeter was able to quantitatively measure the urine glucose level more accurate than urine glucose test strips. Hence, this computer-based polarimeter could be used as an alternative for early detection of urine glucose with noninvasive and painless characteristics.

  4. Prevalence of caffeine use in elite athletes following its removal from the World Anti-Doping Agency list of banned substances.

    PubMed

    Del Coso, Juan; Muñoz, Gloria; Muñoz-Guerra, Jesús

    2011-08-01

    The aim of this investigation was to determine the use of caffeine by athletes after its removal from the World Anti-Doping Agency list. For this purpose, we measured the caffeine concentration in 20 686 urine samples obtained for doping control from 2004 to 2008. We utilized only urine samples obtained after official national and international competitions. Urine caffeine concentration was determined using alkaline extraction followed by gas chromatography-mass spectrometry. The limit of detection (LOD) was set at 0.1 µg·mL(-1). The percentage of urine samples below the LOD was 26.2%; the remaining 73.8% of the urine samples contained caffeine. Most urine samples (67.3%) had urinary caffeine concentrations below 5 µg·mL(-1). Only 0.6% of urine samples exceeded the former threshold for caffeine doping (12 µg·mL(-1)). Triathlon (3.3 ± 2.2 µg·mL(-1)), cycling (2.6 ± 2.0 µg·mL(-1)), and rowing (1.9 ± 1.4 µg·mL(-1)) were the sports with the highest levels of urine caffeine concentration; gymnastics was the sport with the lowest urine caffeine concentration (0.5 ± 0.4 µg·mL(-1)). Older competitors (>30 y) had higher levels of caffeine in their urine than younger competitors (<20 y; p < 0.05); there were no differences between males and females. In conclusion, 3 out of 4 athletes had consumed caffeine before or during sports competition. Nevertheless, only a small proportion of these competitors (0.6%) had a urine caffeine concentration higher than 12 µg·mL(-1). Endurance sports were the disciplines showing the highest urine caffeine excretion after competition.

  5. Immunodetection and molecular determination of visceral and cutaneous Leishmania infection using patients' urine.

    PubMed

    Mirzaei, Asad; Ahmadipour, Fereshteh; Cannet, Arnaud; Marty, Pierre; Delaunay, Pascal; Perrin, Pascale; Dorkeld, Franck; Sereno, Denis; Akhoundi, Mohammad

    2018-05-27

    The diagnosis of leishmaniasis relies mainly on the use of invasive processes, to collect the biological material for detecting Leishmania parasites. Body fluids, which can be collected by non-invasive process, would greatly facilitate the leishmaniasis diagnosis. In the present study, we investigated the potency of urine immunoblotting to diagnose cutaneous and visceral leishmaniasis and we compared with routine molecular methods. A total of 80 samples, including 40 sera and their 40 corresponding urine samples were collected from 37 suspected patients with cutaneous and visceral leishmaniasis, and 3 healthy individuals (as control), in Ilam and Ardabil provinces of Iran. All sera and urine samples were analyzed, using immunoblotting. The confirmation of leishmaniasis infection was performed, using conventional and quantitative PCRs as well as by sequencing the amplicons. Among 37 suspected patients, 23 patients presented cutaneous lesions (CL) and 14 exhibited clinical symptoms reminiscent of visceral leishmaniasis (L. infantum). Among cutaneous patients, 15 were positive for zoonotic cutaneous leishmaniasis (L. major), and eight for anthroponotic cutaneous leishmaniasis (L. tropica). Molecular quantification of Leishmania parasites was performed on sera, urines and cutaneous biopsies of CL and VL patients, demonstrating that parasite load is lower in urines, compared to sera or biopsy. DNA can be detected in 20 out of 23 (86.9%) CL urine samples and in 13 out of 14 (92.8%) VL urine samples. Immunodetection analysis demonstrates that 22 out of 23 (95.6%) sera from CL patients and all patients suspected with VL are positive. For urine samples, 18 out of 23 (78.2%) urine of CL patients and 13 out of 14 (92.8%) urine of VL patients were positive, using Western blot. Therefore, immunodetection and molecular analysis using urine samples can be used as a diagnostic tool for surveying cutaneous and visceral leishmaniasis. Copyright © 2017. Published by Elsevier B.V.

  6. Performance assessment of urine flow cytometry (UFC) to screen urines to reflex to culture in immunocompetent and immunosuppressed hosts.

    PubMed

    Stefanovic, Aleksandra; Roscoe, Diane; Ranasinghe, Romali; Wong, Titus; Bryce, Elizabeth; Porter, Charlene; Lim, Adelina; Grant, Jennifer; Ng, Karen; Pudek, Morris

    2017-09-01

    Urine flow cytometry (UFC) is an automated method to quantify bacterial and white blood cell (WBC) counts. We aimed to determine whether a threshold for these parameters can be set to use UFC as a sensitive screen to predict which urine samples will subsequently grow in culture. Urines submitted to our microbiology laboratory at a tertiary care centre from 22 July 2015-17 February 2016 underwent UFC (Sysmex UF-1000i) analysis, regular urinalysis and urine culture. Positive urine cultures were defined as growth ≥104 c.f.u. ml-1 of organisms associated with urinary tract infections. The correlation of UFC bacterial and WBC counts with urine culture was assessed using receiver operating characteristics curves. The sensitivity (SN), specificity (SP), negative predictive values (NPVs), positive predictive values (PPVs) and false negative rate (FNR) were calculated at various thresholds in immunocompetent and immunosuppressed patients. A total of 15 046 urine specimens were submitted, of which 14 908 were analysable in the study. The average time to UFC result from receipt in the laboratory was 0.76 h (+/-1.04). The test performance at a set threshold of UFC bacteria ≥20 or WBC >5 was: SN=96.0 %, SP=39.2 %, PPV=47.0 %, NPV=94.5 % and FNR=4.0 %. This threshold eliminates 26 % of urine cultures. Immunosuppressed hosts had a lower sensitivity of 90.6 % and a higher FNR of 9.4 %. UFC is a rapid and sensitive method to screen out urine samples that will subsequently be negative and to reflex urines to culture that will subsequently grow. UFC results are available within 1 h from receipt and enable the elimination of culture when the set threshold is not met.

  7. Correlation of random urine protein creatinine (P-C) ratio with 24-hour urine protein and P-C ratio, based on physical activity: a pilot study.

    PubMed

    Sadjadi, Seyed-Ali; Jaipaul, Navin

    2010-09-07

    Quantification of proteinuria is usually predicated upon 24-hour urine collection. Multiple factors influence urine collection and the rate of protein and creatinine excretion. Urine collection is often incomplete, and therefore creatinine and protein excretion rates are underestimated. A random urine protein-creatinine (P-C) ratio has been shown over the years to be a reliable alternative to the 24-hour collection for detection and follow up of proteinuria. However, urine protein excretion may be influenced by physical activity. We studied 48 patients with proteinuria and varying levels of physical activity to determine the correlation between the measures of urine protein excretion. The correlation coefficient (r) between 24-hour urine total protein and random urine P-C ratio was 0.75 (P < 0.01) in the overall study population, but varied according to the level of proteinuria and physical activity in a stratified analysis: r = 0.99 (P < 0.001) and r = 0.95 (P < 0.01) in bedridden patients; r = 0.44 (P = not significant [NS]) and r = 0.54 (P = NS) in semiactive patients; and r = 0.44 (P = NS) and r = 0.58 (P < 0.05) in active patients with nephrotic- (>3500 mg/day) and non-nephrotic (<3500 mg/day) range proteinuria, respectively. The correlation appeared to be stronger between random urine and 24-hour urine P-C ratio for the overall study population (r = 0.84; P < 0.001), and when stratified according to the level of proteinuria and physical activity: r = 0.99 (P < 0.001) and r = 0.92 (P < 0.01) in bedridden patients; r = 0.61 (P = NS) and r = 0.54 (P = NS) in semiactive patients; and r = 0.64 (P < 0.02) and r = 0.52 (P < 0.05) in active patients with nephrotic and non-nephrotic range proteinuria, respectively. We conclude that the random urine P-C ratio is a reliable and practical way of estimating and following proteinuria, but its precision and accuracy may be affected by the level of patient physical activity.

  8. Correlation of random urine protein creatinine (P-C) ratio with 24-hour urine protein and P-C ratio, based on physical activity: a pilot study

    PubMed Central

    Sadjadi, Seyed-Ali; Jaipaul, Navin

    2010-01-01

    Quantification of proteinuria is usually predicated upon 24-hour urine collection. Multiple factors influence urine collection and the rate of protein and creatinine excretion. Urine collection is often incomplete, and therefore creatinine and protein excretion rates are underestimated. A random urine protein-creatinine (P-C) ratio has been shown over the years to be a reliable alternative to the 24-hour collection for detection and follow up of proteinuria. However, urine protein excretion may be influenced by physical activity. We studied 48 patients with proteinuria and varying levels of physical activity to determine the correlation between the measures of urine protein excretion. The correlation coefficient (r) between 24-hour urine total protein and random urine P-C ratio was 0.75 (P < 0.01) in the overall study population, but varied according to the level of proteinuria and physical activity in a stratified analysis: r = 0.99 (P < 0.001) and r = 0.95 (P < 0.01) in bedridden patients; r = 0.44 (P = not significant [NS]) and r = 0.54 (P = NS) in semiactive patients; and r = 0.44 (P = NS) and r = 0.58 (P < 0.05) in active patients with nephrotic- (>3500 mg/day) and non-nephrotic (<3500 mg/day) range proteinuria, respectively. The correlation appeared to be stronger between random urine and 24-hour urine P-C ratio for the overall study population (r = 0.84; P < 0.001), and when stratified according to the level of proteinuria and physical activity: r = 0.99 (P < 0.001) and r = 0.92 (P < 0.01) in bedridden patients; r = 0.61 (P = NS) and r = 0.54 (P = NS) in semiactive patients; and r = 0.64 (P < 0.02) and r = 0.52 (P < 0.05) in active patients with nephrotic and non-nephrotic range proteinuria, respectively. We conclude that the random urine P-C ratio is a reliable and practical way of estimating and following proteinuria, but its precision and accuracy may be affected by the level of patient physical activity. PMID:20856681

  9. Feasibility of collecting 24-h urine to monitor sodium intake in the National Health and Nutrition Examination Survey123

    PubMed Central

    Terry, Ana L; Cogswell, Mary E; Wang, Chia-Yih; Chen, Te-Ching; Loria, Catherine M; Wright, Jacqueline D; Zhang, Xinli; Lacher, David A; Merritt, Robert K; Bowman, Barbara A

    2016-01-01

    Background: Twenty-four–hour urine sodium excretion is recommended for monitoring population sodium intake. Because of concerns about participation and completion, sodium excretion has not been collected previously in US nationally representative surveys. Objective: We assessed the feasibility of implementing 24-h urine collections as part of a nationally representative survey. Design: We selected a random half sample of nonpregnant US adults aged 20–69 y in 3 geographic locations of the 2013 NHANES. Participants received explicit instructions, started and ended the urine collection in a urine study mobile examination center, and answered questions about their collection. Among those with a complete 24-h urine collection, a random one-half were asked to collect a second 24-h urine sample. Sodium, potassium, chloride, and creatinine excretion were analyzed. Results: The final NHANES examination response rate for adults aged 20–69 y in these 3 study locations was 71%. Of those examined (n = 476), 282 (59%) were randomly selected to participate in the 24-h urine collection. Of these, 212 persons [75% of those selected for 24-h urine collection; 53% (equal to 71% × 75% of those selected for the NHANES)] collected a complete initial 24-h specimen and 92 persons (85% of 108 selected) collected a second complete 24-h urine sample. More men than women completed an initial collection (P = 0.04); otherwise, completion did not vary by sociodemographic characteristics, body mass index, education, or employment status for either collection. Mean 24-h urine volume and sodium excretion were 1964 ± 1228 mL and 3657 ± 2003 mg, respectively, for the first 24-h urine sample, and 2048 ± 1288 mL and 3773 ± 1891 mg, respectively, for the second collection. Conclusion: Given the 53% final component response rate and 75% completion rate, 24-h urine collections were deemed feasible and implemented in the NHANES 2014 on a subsample of adults aged 20–69 y to assess population sodium intake. This study was registered at clinicaltrials.gov as NCT02723682. PMID:27413136

  10. Nonhazardous Urine Pretreatment Method

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Holtsnider, John T.

    2012-01-01

    A method combines solid phase acidification with two non-toxic biocides to prevent ammonia volatilization and microbial proliferation. The safe, non-oxidizing biocide combination consists of a quaternary amine and a food preservative. This combination has exhibited excellent stabilization of both acidified and unacidified urine. During pretreatment tests, composite urine collected from donors was challenged with a microorganism known to proliferate in urine, and then was processed using the nonhazardous urine pre-treatment method. The challenge microorganisms included Escherichia coli, a common gram-negative bacteria; Enterococcus faecalis, a ureolytic gram-positive bacteria; Candida albicans, a yeast commonly found in urine; and Aspergillus niger, a problematic mold that resists urine pre-treatment. Urine processed in this manner remained microbially stable for over 57 days. Such effective urine stabilization was achieved using non-toxic, non-oxidizing biocides at higher pH (3.6 to 5.8) than previous methods in use or projected for use aboard the International Space Station (ISS). ISS urine pretreatment methods employ strong oxidants including ozone and hexavalent chromium (Cr(VI)), a carcinogenic material, under very acidic conditions (pH = 1.8 to 2.4). The method described here offers a much more benign chemical environment than previous pretreatment methods, and will lower equivalent system mass (ESM) by reducing containment volume and mass, system complexity, and crew time needed to handle pre-treatment chemicals. The biocides, being non-oxidizing, minimize the potential for chemical reactions with urine constituents to produce volatile, airborne contaminants such as cyanogen chloride. Additionally, the biocides are active under significantly less acidic conditions than those used in the current system, thereby reducing the degree of required acidification. A simple flow-through solid phase acidification (SPA) bed is employed to overcome the natural buffering capacity of urine, and to lower the pH to levels that fix ammoniacal nitrogen in the non-volatile and highly water soluble NH4 + form. Citric acid, a highly soluble, solid tricarboxylic acid essential to cellular metabolism, and typically used as a food preservative, has also been shown to efficiently acidify urine in conjunction with non-oxidizing biocides to provide effective stabilization with respect to both microbial growth and ammonia volatilization.

  11. Diagnostic Performance of Afternoon Urine Osmolality to Assess Optimal Hydration Status in an Adult Healthy Population.

    PubMed

    Hustrini, Ni Made; Siregar, Parlindungan; Nainggolan, Ginova; Harimurti, Kuntjoro

    2017-04-01

    optimal hydration represents adequate total daily fluid intake to compensate for daily water losses, ensure adequate urine output to reduce the risk of urolithiasis and renal function decline, and also avoid the production of arginine vasopressin (AVP). Twenty-four-hour urine osmolality has been used to assess hydration status, but it is challenging because of the possibility of spilling urine and limitation of daily activities. This study is aimed to determine the performance of the afternoon urine osmolality to assess the optimal hydration status compared with 24-hour urine osmolality. a cross sectional study was conducted on healthy employees aged 18-59 years at Universitas Indonesia Medical Faculty/Cipto Mangunkusumo Hospital, with consecutive sampling method. The ROC curve was analyzed to obtain the optimal cut off point and the accuracy of the afternoon urine osmolality in assessing the optimal hydration status. between August-September 2016 there were 120 subjects (73.8% female, median age 32 years) who met the study criteria with a median 24-hour urine osmolality 463.5 (95% CI, 136-1427) mOsm/kg H2O and median afternoon urine osmolality 513 (95% CI, 73-1267). We found moderate correlation (r=0.59; p<0.001) between afternoon urine osmolality and a 24-hour urine osmolality. Using ROC curve, the AUC value was 0.792 (95% CI, 0.708-0.875) with the cut off 528 mOsm/kg H2O. To assess the optimal hydration status, the afternoon urine osmolality had the sensitivity of 0.7 (95% CI, 0.585-0.795) and the specificity of 0.76 (95% CI, 0.626-0.857), Likelihood Ratio (LR) (+) 2.917 (95% CI, 1.74-4.889) and LR (-) 0.395 (95% CI, 0.267-0.583). afternoon urine osmolality can be used as a diagnostic tool to assess the optimal hydration status in healthy population with cut off 528 mOsm/kg H2O, sensitivity of 0.7, and specificity of 0.76.

  12. The Diagnostic Accuracy of Urine-Based Xpert MTB/RIF in HIV-Infected Hospitalized Patients Who Are Smear-Negative or Sputum Scarce

    PubMed Central

    Peter, Jonathan G.; Theron, Grant; Muchinga, Tapuwa E.; Govender, Ureshnie; Dheda, Keertan

    2012-01-01

    Background Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients. Methodology/Principal Findings 281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity). Conclusions/Significance This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity. PMID:22815718

  13. Prognostic Value of Residual Urine Volume, GFR by 24-hour Urine Collection, and eGFR in Patients Receiving Dialysis.

    PubMed

    Lee, Mi Jung; Park, Jung Tak; Park, Kyoung Sook; Kwon, Young Eun; Oh, Hyung Jung; Yoo, Tae-Hyun; Kim, Yong-Lim; Kim, Yon Su; Yang, Chul Woo; Kim, Nam-Ho; Kang, Shin-Wook; Han, Seung Hyeok

    2017-03-07

    Residual kidney function can be assessed by simply measuring urine volume, calculating GFR using 24-hour urine collection, or estimating GFR using the proposed equation (eGFR). We aimed to investigate the relative prognostic value of these residual kidney function parameters in patients on dialysis. Using the database from a nationwide prospective cohort study, we compared differential implications of the residual kidney function indices in 1946 patients on dialysis at 36 dialysis centers in Korea between August 1, 2008 and December 31, 2014. Residual GFR calculated using 24-hour urine collection was determined by an average of renal urea and creatinine clearance on the basis of 24-hour urine collection. eGFR-urea, creatinine and eGFR β 2 -microglobulin were calculated from the equations using serum urea and creatinine and β 2 -microglobulin, respectively. The primary outcome was all-cause death. During a mean follow-up of 42 months, 385 (19.8%) patients died. In multivariable Cox analyses, residual urine volume (hazard ratio, 0.96 per 0.1-L/d higher volume; 95% confidence interval, 0.94 to 0.98) and GFR calculated using 24-hour urine collection (hazard ratio, 0.98; 95% confidence interval, 0.95 to 0.99) were independently associated with all-cause mortality. In 1640 patients who had eGFR β 2 -microglobulin data, eGFR β 2 -microglobulin (hazard ratio, 0.98; 95% confidence interval, 0.96 to 0.99) was also significantly associated with all-cause mortality as well as residual urine volume (hazard ratio, 0.96 per 0.1-L/d higher volume; 95% confidence interval, 0.94 to 0.98) and GFR calculated using 24-hour urine collection (hazard ratio, 0.97; 95% confidence interval, 0.95 to 0.99). When each residual kidney function index was added to the base model, only urine volume improved the predictability for all-cause mortality (net reclassification index =0.11, P =0.01; integrated discrimination improvement =0.01, P =0.01). Higher residual urine volume was significantly associated with a lower risk of death and exhibited a stronger association with mortality than GFR calculated using 24-hour urine collection and eGFR-urea, creatinine. These results suggest that determining residual urine volume may be beneficial to predict patient survival in patients on dialysis. Copyright © 2017 by the American Society of Nephrology.

  14. Low cadmium exposure in males and lactating females–estimation of biomarkers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stajnko, Anja

    Background: Urine cadmium (Cd) and renal function biomarkers, mostly analysed in urine spot samples, are well established biomarkers of occupational exposure. Their use and associations at low environmental level are common, but have recently been questioned, particularly in terms of physiological variability and normalisation bias in the case of urine spot samples. Aim: To determine the appropriateness of spot urine and/or blood Cd exposure biomarkers and their relationships with renal function biomarkers at low levels of exposure. To this end, we used data from Slovenian human biomonitoring program involving 1081 Slovenians (548 males, mean age 31 years; 533 lactating females,more » mean age 29 years; 2007–2015) who have not been exposed to Cd occupationally. Results: Geometric means (GMs) of Cd in blood and spot urine samples were 0.27 ng/mL (0.28 for males and 0.33 for females) and 0.19 ng/mL (0.21 for males and 0.17 for females), respectively. Differing results were obtained when contrasting normalisation by urine creatinine with specific gravity. GMs of urine albumin (Alb), alpha-1-microglobulin (A1M), N-acetyl-beta-glucosaminidase (NAG), and immunoglobulin G (IgG) were far below their upper reference limits. Statistical analysis of unnormalised or normalised urine data often yielded inconsistent and conflicting results (or trends), so association analyses with unnormalised data were taken as more valid. Relatively weak positive associations were observed between urine Cd (ng/mL) and blood Cd (β=0.11, p=0.002 for males and β=0.33, p<0.001 for females) and for females between urine NAG and blood Cd (β=0.14, p=0.04). No associations were found between other renal function biomarkers and blood Cd. Associations between Cd and renal function biomarkers in urine were stronger (p<0.05, β=0.11–0.63). Mostly, all of the associations stayed significant but weakened after normalisation for diuresis. In the case of A1M, its associations with Cd were influenced by current smoking and blood Pb in males and by pre-pregnancy smoking and blood Se in females (β up to 0.34, p<0.001). Statistical analysis of unnormalised or normalised urine data often yielded inconsistent and conflicting results (or trends), so association analyses data with unnormalised were taken as more valid. Conclusions: The observed uncertainties introduced by urine normalisation, particularly by creatinine, confirm blood Cd as a superior low-Cd exposure biomarker versus urine Cd in cases when 24 h urine is unattainable. Evidence that A1M can be positively related to Cd, smoking (current or pre-pregnancy), Pb, and Se status, points to the versatile biological functions of A1M. - Highlights: • Creatinine normalisation of spot urine data is inappropriate at low Cd exposure. • Blood Cd as low-Cd exposure biomarker is superior over spot urine Cd. • Cd in urine, but not in blood, was significantly associated with A1M. • A1M – Cd relations were influenced by smoking, Se and less so by Pb.« less

  15. 49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...

  16. 49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...

  17. 49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...

  18. 49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...

  19. 49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...

  20. Potential semiochemicals in urine from free ranging wolverines (Gulo gulo Pallas, 1780)

    Treesearch

    William F. Wood; Jeffrey P. Copeland; Richard E. Yates; Iman K. Horsey; Lynne R. McGreevy

    2009-01-01

    Urine deposition has been observed as an important scent-marking behaviour among wolverines (Gulo gulo, Mustelinae, Mustelidae). Solid phase microextraction (SPME) of headspace volatiles of the urine from free ranging wolverines were examined by gas chromatography-mass spectrometry (GC-MS). Urine samples were collected directly from the bladder of live-trapped animals...

  1. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that measures directly or indirectly the volume or flow of urine from a patient, either during the course of... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urine flow or volume measuring system. 876.1800...

  2. Clinical evaluation and use of urine screening for drug abuse.

    PubMed Central

    Saxon, A J; Calsyn, D A; Haver, V M; Delaney, C J

    1988-01-01

    Urine drug screening is indicated to evaluate patients who show mental status or behavioral changes and to monitor the abstinence of drug abusers. The appropriate timing for collecting urine specimens may vary depending on the suspected drug of abuse and on laboratory factors. Laboratories use a variety of techniques to do urine screens, and these must be understood by clinicians ordering the screens to interpret results correctly. In treating drug-abusing patients, clinicians must apply structured reinforcement in conjunction with urine screen results to aid patients in achieving abstinence. PMID:3176489

  3. Use of urine in snow to indicate condition of wolves

    USGS Publications Warehouse

    Mech, L.D.; Seal, U.S.; DelGiudice, G.D.

    1987-01-01

    Urine deposited in snow by wild gray wolves (Canis lupus) and by fed and fasted captive wolves was analyzed for urea nitrogen, calcium, sodium, potassium, and creatinine. Ratios of the elements with creatinine were considerably higher for fed than for fasted animals, and ratios for fed wolves compared favorably with ratios from wolf urine in snow along trails leading from kills. Thus, wolf urine in the snow can indicate whether wolves have fed recently, and a series of such urine collections from any given pack can indicate relative nutritional state.

  4. Development testing of a shuttle urine collection system

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Flight tests conducted in December 1973 demonstrated the ability of an unisexual urine collection subsystem to function in a zero-g environment. The urinal, which could be adjusted with three degrees of freedom, accommodated 16 female test subjects with a wide range of stature, as well as five male test subjects. The urinal was in intimate contact with the female and was contoured to form an effective air seal at the periphery. When positioned 2-4 inches forward, the urinal could be used for male collection and contact was not required.

  5. Survey of antibiotic residues in Canadian slaughter animals.

    PubMed Central

    Tittiger, F; Kingscote, B; Meldrum, B; Prior, M

    1975-01-01

    Kidneys and urine of cattle, swine, sheep and chickens were tested for bacterial growth inhibitors using Bacillus subtilis and Sarcina lutea as test organisms. Results were as follows: 211 beef kidneys four positive, 611 swine kidneys five positive, 27 sheep and 120 chicken kidneys all negative, 2108 beef urine 76 positive, 2409 swine urine 186 positive, 176 sheep urine 17 positive. Strongest reactions were obtained with B. subtilis on phosphate buffered pH 6.0 plates. Larger zones were produced by urine from injected animals than by tissue samples. PMID:236082

  6. Variations in Urine Calcium Isotope: Composition Reflect Changes in Bone Mineral Balance in Humans

    NASA Technical Reports Server (NTRS)

    Skulan, Joseph; Anbar, Ariel; Bullen, Thomas; Puzas, J. Edward; Shackelford, Linda; Smith, Scott M.

    2004-01-01

    Changes in bone mineral balance cause rapid and systematic changes in the calcium isotope composition of human urine. Urine from subjects in a 17 week bed rest study was analyzed for calcium isotopic composition. Comparison of isotopic data with measurements of bone mineral density and metabolic markers of bone metabolism indicates the calcium isotope composition of urine reflects changes in bone mineral balance. Urine calcium isotope composition probably is affected by both bone metabolism and renal processes. Calcium isotope. analysis of urine and other tissues may provide information on bone mineral balance that is in important respects better than that available from other techniques, and illustrates the usefulness of applying geochemical techniques to biomedical problems.

  7. Excretion profile of boldenone in urine of veal calves fed two different milk replacers.

    PubMed

    Draisci, R; Merlanti, R; Ferretti, G; Fantozzi, L; Ferranti, C; Capolongo, F; Segato, S; Montesissa, C

    2007-03-14

    The residue profiles of 17alpha-/17beta-boldenone conjugated (17alpha/beta-Bol) and ADD were investigated by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in urine of male veal calves fed two commercial milk replacers, with different content of cholesterol and phytosterols. The urine samples were collected within 4 h after feeding and further from all the animals. Detectable amounts of 17alpha-Bol conjugated were measured in urine collected from all calves, but the concentrations of 17alpha-Bol were higher in urine from calves receiving the milk replacer with the greater amount of phytosterols. During the whole experiment, 17beta-Bol and ADD were never detected in urine samples collected.

  8. Analysis of Urine as Indicators of Specific Body Conditions

    NASA Astrophysics Data System (ADS)

    Dey, Souradeep; Saha, Triya; Narendrakumar, Uttamchand

    2017-11-01

    Urinalysis can be defined as a procedure for examining various factors of urine, which include physical properties, particulate matter, cells, casts, crystals, organisms and solutes. Urinalysis is recommended to be a part of the initial examination of all patients as its cheap, feasible and gives productive results. This paper focuses on the analysis of urine collected at specific body conditions. Here we illustrate the urine profile of different persons having various body conditions, which include, having urinary tract infection, undergoing strenuous exercise, having back pain regularly, having very low urine output and a person who is on 24 hours of diet. Examination of urine collected from different persons having specific body conditions usually helps us in the diagnosis of various diseases, which it indicates.

  9. Dyslipidemia in people living with HIV-AIDS in a tertiary hospital in South-East Nigeria.

    PubMed

    Anyabolu, Ernest Ndukaife

    2017-01-01

    Across the globe, human immunodeficiency virus (HIV) infection is a healthcare problem. Dyslipidemia, a cardiovascular risk factor, is known to occur with the progression of HIV infection. The factors which influence dyslipidemia in HIV subjects have not been completely identified. The aim of this study was to evaluate serum lipids and identify the factors which might influence dyslipidemia in treatment-naïve HIV subjects in Owerri, Nigeria. This was a cross-sectional study of treatment-naïve HIV subjects. Anthropometric and demographic data were collected. Serum LDL serum cholesterol, serum high density lipoprotein cholesterol, serum triglyceride, spot urine creatinine, spot urine osmolality, spot urine protein, serum creatinine, 24-hour urine protein, 24-hour urine osmolality, 24-hour urine creatinine, creatinine clearance and hemoglobin were conducted. The variables were compared between those who have dyslipidemia and those who have no dyslipidemia. The mean age of the subjects was 39 ± 11 years. Females constituted 72.0% and males 28.0%. Elevated serum LDL was present in 17.6%, elevated serum total cholesterol in 11.4%, elevated serum triglyceride in 9.9% and low serum HDL in 34.4% of the subjects. There was significant association between dyslipidemia and CD4 cells count, as well as anemia. There was no significant association between dyslipidemia and urine protein, urine creatinine, urine osmolality, creatinine clearance, as well as 24-hour urine volume. The prevalence of dyslipidemia was high in the study subjects. Abnormal CD4 cells count and anemia were common in treatment-naïve HIV subjects who have dyslipidemia.

  10. Prothrombin fragment 1+2 in urine as a marker on coagulation activity in patients with suspected pulmonary embolism.

    PubMed

    Wexels, Fredrik; Dahl, Ola E; Pripp, Are H; Seljeflot, Ingebjørg; Borris, Lars C; Haslund, Anniken; Gudmundsen, Tor E; Lauritzen, Trine; Lassen, Michael R

    2014-07-01

    We have recently reported that increased levels of urine prothrombin fragment 1+2 reflected radiologically verified deep vein thrombosis. In this study we evaluated whether urine prothrombin fragment 1+2 was associated with pulmonary embolism in non-selected patients. Patients with clinical suspected pulmonary embolism were interviewed on comorbidities and medications. Urine was collected from each patient before radiological examination and snap frozen until analysed on urine prothrombin fragment 1+2 with an ELISA kit. Imaging of the pulmonary arteries were conducted with contrast enhanced computer tomography. Pulmonary embolism was diagnosed in 44/197 patients. Non-significantly higher urine prothrombin fragment 1+2 levels were found in non-selected patients with pulmonary embolism vs. those without (p=0.324). Significantly higher urine prothrombin fragment 1+2 levels were found in the pulmonary embolism positive patients without comorbidities (n=13) compared to the control group (n=28) (p=0.009). The calculated sensitivity, specificity and negative predictive value using the lowest detectable urine prothrombin fragment 1+2 level was 82%, 34% and 87%, respectively. There was no significant urine prothrombin fragment 1+2 level difference in patients with and without pulmonary embolism. In non-comorbide pulmonary embolism positive patients the urine prothrombin fragment 1+2 levels were significantly higher compared to the control group. The negative predictive value found in this study indicates that uF1+2 has the potential to identify patients with a low risk of PE. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. High Resolution Size Analysis of Fetal DNA in the Urine of Pregnant Women by Paired-End Massively Parallel Sequencing

    PubMed Central

    Tsui, Nancy B. Y.; Jiang, Peiyong; Chow, Katherine C. K.; Su, Xiaoxi; Leung, Tak Y.; Sun, Hao; Chan, K. C. Allen; Chiu, Rossa W. K.; Lo, Y. M. Dennis

    2012-01-01

    Background Fetal DNA in maternal urine, if present, would be a valuable source of fetal genetic material for noninvasive prenatal diagnosis. However, the existence of fetal DNA in maternal urine has remained controversial. The issue is due to the lack of appropriate technology to robustly detect the potentially highly degraded fetal DNA in maternal urine. Methodology We have used massively parallel paired-end sequencing to investigate cell-free DNA molecules in maternal urine. Catheterized urine samples were collected from seven pregnant women during the third trimester of pregnancies. We detected fetal DNA by identifying sequenced reads that contained fetal-specific alleles of the single nucleotide polymorphisms. The sizes of individual urinary DNA fragments were deduced from the alignment positions of the paired reads. We measured the fractional fetal DNA concentration as well as the size distributions of fetal and maternal DNA in maternal urine. Principal Findings Cell-free fetal DNA was detected in five of the seven maternal urine samples, with the fractional fetal DNA concentrations ranged from 1.92% to 4.73%. Fetal DNA became undetectable in maternal urine after delivery. The total urinary cell-free DNA molecules were less intact when compared with plasma DNA. Urinary fetal DNA fragments were very short, and the most dominant fetal sequences were between 29 bp and 45 bp in length. Conclusions With the use of massively parallel sequencing, we have confirmed the existence of transrenal fetal DNA in maternal urine, and have shown that urinary fetal DNA was heavily degraded. PMID:23118982

  12. Interferences of homogentisic acid (HGA) on routine clinical chemistry assays in serum and urine and the implications for biochemical monitoring of patients with alkaptonuria.

    PubMed

    Curtis, S L; Roberts, N B; Ranganath, L R

    2014-05-01

    We have assessed the effect of elevated concentrations of homogentisic acid (HGA) as in alkaptonuria (AKU), on a range of routine chemistry tests in serum and urine. HGA was added to pooled serum and a range of assays was analysed with Roche Modular chemistries. Effects on urine were assessed by diluting normal urine with urine from a patient with AKU, adding HGA to urine and after lowering output of urinary HGA with nitisinone treatment. Serum enzymatic creatinine showed 30% negative interference with 100μmol/L HGA and >50% at 400μmol/L. Serum urate 100 to 480μmol/L was reduced up to 20% at 100 and to 50% with 400μmol/L HGA. Serum cholesterol between 3 and 11mmol/L was reduced by 0.5mmol/L with 400μmol/L HGA. Urine enzymatic creatinine and urate with >2mmol/L HGA showed concentration dependent negative interference up to 80%. A positive interference in urine total protein by benzethonium turbidometric assay was observed, with 10mmol/L HGA equivalent to 1g/L protein. Jaffe creatinine, Na, K, Cl, Mg, Ca, phosphate, ALT, GGT, ALP activities and urea in serum and or urine were not affected by increases in HGA. To avoid interferences by HGA in alkaptonuria concentration of HGA should be established before samples are assayed with peroxidase assays and benzethonium urine protein. Copyright © 2013 The Canadian Society of Clinical Chemists. All rights reserved.

  13. Urine specimen validity test for drug abuse testing in workplace and court settings.

    PubMed

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  14. Latent association between low urine pH and low body weight in an apparently healthy population.

    PubMed

    Nakajima, Kei; Oda, Eiji; Kanda, Eiichiro

    2016-01-01

    Low urine pH, a plausible predictor for chronic kidney disease and metabolic disorders, is often observed in obese individuals. However, the association between low urine pH and low body weight is equivocal. We examined clinical parameters including urine pH and body mass index (BMI) in a cross-sectional study of 3629 apparently healthy Japanese adults aged 25-80 years who underwent a health-screening check-up. Urine pH was lower and the prevalence of proteinuria was significantly higher in subjects with BMI of ≥ 27.0 kg/m(2) compared with those with BMI of 21.0-22.9 kg/m(2). By contrast, hematuria was more prevalent in subjects with BMI of ≤ 20.9 kg/m(2). Logistic regression analysis showed that BMI of ≥ 27.0 kg/m(2) was significantly associated with low urine pH (≤ 5.5), which remained significant after adjustment for relevant confounders including age, sex, proteinuria, estimated glomerular filtration rate, urine density, hematuria, smoking status, and daily alcohol drinking. However, the association disappeared after further adjustment for serum uric acid. In contrast, the association between low urine pH and BMI of ≤ 19.0 kg/m(2) was significant after adjustment for age and sex and rather strengthened by the further adjustment for serum uric acid. In conclusion, low urine pH may be independently associated with low BMI. However, the underlying mechanisms of low urine pH in low body weight may differ from those in high body weight.

  15. Urine podocyte mRNAs mark disease activity in IgA nephropathy

    PubMed Central

    Fukuda, Akihiro; Sato, Yuji; Iwakiri, Takashi; Komatsu, Hiroyuki; Kikuchi, Masao; Kitamura, Kazuo; Wiggins, Roger C.; Fujimoto, Shouichi

    2015-01-01

    Background Podocyte depletion is a major mechanism driving glomerulosclerosis. We and others have previously projected from model systems that podocyte-specific mRNAs in the urine pellet might serve as glomerular disease markers. We evaluated IgA nephropathy (IgAN) to test this concept. Methods From 2009 to 2013, early morning voided urine samples and kidney biopsies from IgAN patients (n = 67) were evaluated in comparison with urine samples from healthy age-matched volunteers (n = 28). Urine podocyte (podocin) mRNA expressed in relation to either urine creatinine concentration or a kidney tubular marker (aquaporin 2) was tested as markers. Results Urine podocyte mRNAs were correlated with the severity of active glomerular lesions (segmental glomerulosclerosis and acute extracapillary proliferation), but not with non-glomerular lesions (tubular atrophy/interstitial fibrosis) or with clinical parameters of kidney injury (serum creatinine and estimated glomerular filtration rate), or with degree of accumulated podocyte loss at the time of biopsy. In contrast, proteinuria correlated with all histological and clinical markers. Glomerular tuft podocyte nuclear density (a measure of cumulative podocyte loss) correlated with tubular atrophy/interstitial fibrosis, estimated-glomerular filtration rate and proteinuria, but not with urine podocyte markers. In a subset of the IgA cohort (n = 19, median follow-up period = 37 months), urine podocyte mRNAs were significantly decreased after treatment, in contrast to proteinuria which was not significantly changed. Conclusions Urine podocyte mRNAs reflect active glomerular injury at a given point in time, and therefore provide both different and additional clinical information that can complement proteinuria in the IgAN decision-making paradigm. PMID:25956757

  16. Does increased urination frequency protect against bladder cancer?

    PubMed

    Silverman, Debra T; Alguacil, Juan; Rothman, Nathaniel; Real, Francisco X; Garcia-Closas, Montserrat; Cantor, Kenneth P; Malats, Nuria; Tardon, Adonina; Serra, Consol; Garcia-Closas, Reina; Carrato, Alfredo; Lloreta, Josep; Samanic, Claudine; Dosemeci, Mustafa; Kogevinas, Manolis

    2008-10-01

    Experimental studies suggest that increased urination frequency may reduce bladder cancer risk if carcinogens are present in the urine. Only 2 small studies of the effect of increased urination frequency on bladder cancer risk in humans have been conducted with conflicting results. Our purpose was to evaluate the effect of urination frequency on risk of bladder cancer in a large, multicenter case-control study. We analyzed data based on interviews conducted with 884 patients with newly diagnosed, bladder cancer and 996 controls from 1998 to 2001 in Spain. We observed a consistent, inverse trend in risk with increasing nighttime voiding frequency in both men (p = 0.0003) and women (p = 0.07); voiding at least 2 times per night was associated with a significant, 40-50% risk reduction. The protective effect of nocturia was apparent among study participants with low, moderate and high water consumption. The risk associated with cigarette smoking was reduced by nocturia. Compared with nonsmokers who did not urinate at night, current smokers who did not urinate at night had an OR of 7.0 (95% CI = 4.7-10.2), whereas those who voided at least twice per night had an OR of 3.3 (95% CI = 1.9-5.8) (p value for trend = 0.0005). Our findings suggest a strong protective effect of nocturia on bladder cancer risk, providing evidence in humans that bladder cancer risk is related to the contact time of the urothelium with carcinogens in urine. Increased urination frequency, coupled with possible dilution of the urine from increased water intake, may diminish the effect of urinary carcinogens on bladder cancer risk.

  17. Spatial inter-comparison of Top-down emission inventories in European urban areas

    NASA Astrophysics Data System (ADS)

    Trombetti, Marco; Thunis, Philippe; Bessagnet, Bertrand; Clappier, Alain; Couvidat, Florian; Guevara, Marc; Kuenen, Jeroen; López-Aparicio, Susana

    2018-01-01

    This paper presents an inter-comparison of the main Top-down emission inventories currently used for air quality modelling studies at the European level. The comparison is developed for eleven European cities and compares the distribution of emissions of NOx, SO2, VOC and PPM2.5 from the road transport, residential combustion and industry sectors. The analysis shows that substantial differences in terms of total emissions, sectorial emission shares and spatial distribution exist between the datasets. The possible reasons in terms of downscaling approaches and choice of spatial proxies are analysed and recommendations are provided for each inventory in order to work towards the harmonisation of spatial downscaling and proxy calibration, in particular for policy purposes. The proposed methodology may be useful for the development of consistent and harmonised European-wide inventories with the aim of reducing the uncertainties in air quality modelling activities.

  18. Intercomparison of Primary Manometers in the Range 30 kPa to 110 kPa: Pressure Balance at the LNE and Mercury Manometer at the VNIIFTRI

    NASA Astrophysics Data System (ADS)

    Astrov, D. N.; Guillemot, J.; Legras, J. C.; Zakharov, A. A.

    1994-01-01

    An intercomparison between the primary pressure balance of the LNE and a mercury manometer developed at the All-Russian Research Institute for Physical, Technical and Radio-Technical Measurements (VNIIFTRI) for purposes of temperature measurement was undertaken in 1990. A short description of the two standards is given. The transfer standard was a pressure balance equipped with a piston-cylinder assembly that has the same characteristics as the standard of the Laboratoire National d'Essais (LNE). The results obtained from 30 kPa to 110 kPa showed a systematic relative difference of 12 parts in 106 between the two standards. This difference is significant, as the combined relative uncertainty at 1 σ level is estimated to be 4,2 parts in 106. These results are analysed in this paper.

  19. Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, Susanne

    2015-02-09

    We participated in a FASTER SCM intercomparison for which we ran our SCM for 3 years at the SGP to analyze statistics of the precipitation field (Song et al., 2013). An important feature of these simulations was the use of relaxation forcing to observed T, q, which decouples the model convection from the forcing and allows precipitation errors to emerge. Because the GISS cumulus parameterization includes a trigger that prevents convection until sufficient lifting is present, and because convection at the SGP is usually triggered by mesoscale motions that are not represented in the forcing when relaxation is applied, themore » duration of SCM precipitation is shorter than observed (Del Genio and Wolf, 2012) and thus its mean precipitation less than observed. However, its diurnal cycle phase is correct, and it is the only operational cumulus parameterization in the intercomparison that does not produce excessive warm season precipitation under weak large-scale forcing conditions.« less

  20. DCMIP2016: a review of non-hydrostatic dynamical core design and intercomparison of participating models

    NASA Astrophysics Data System (ADS)

    Ullrich, Paul A.; Jablonowski, Christiane; Kent, James; Lauritzen, Peter H.; Nair, Ramachandran; Reed, Kevin A.; Zarzycki, Colin M.; Hall, David M.; Dazlich, Don; Heikes, Ross; Konor, Celal; Randall, David; Dubos, Thomas; Meurdesoif, Yann; Chen, Xi; Harris, Lucas; Kühnlein, Christian; Lee, Vivian; Qaddouri, Abdessamad; Girard, Claude; Giorgetta, Marco; Reinert, Daniel; Klemp, Joseph; Park, Sang-Hun; Skamarock, William; Miura, Hiroaki; Ohno, Tomoki; Yoshida, Ryuji; Walko, Robert; Reinecke, Alex; Viner, Kevin

    2017-12-01

    Atmospheric dynamical cores are a fundamental component of global atmospheric modeling systems and are responsible for capturing the dynamical behavior of the Earth's atmosphere via numerical integration of the Navier-Stokes equations. These systems have existed in one form or another for over half of a century, with the earliest discretizations having now evolved into a complex ecosystem of algorithms and computational strategies. In essence, no two dynamical cores are alike, and their individual successes suggest that no perfect model exists. To better understand modern dynamical cores, this paper aims to provide a comprehensive review of 11 non-hydrostatic dynamical cores, drawn from modeling centers and groups that participated in the 2016 Dynamical Core Model Intercomparison Project (DCMIP) workshop and summer school. This review includes a choice of model grid, variable placement, vertical coordinate, prognostic equations, temporal discretization, and the diffusion, stabilization, filters, and fixers employed by each system.

Top