Sample records for urine reference materials

  1. [Development of the certified reference material of mercury in lyophilized human urine].

    PubMed

    Zhao, Wei; Zhang, Fu-gang; DU, Hui-fang; Pan, Ya-juan; Yan, Hui-fang

    2011-02-01

    To develop the certified reference material of mercury in lyophilized human urine. Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L. The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.

  2. An assessment of contemporary atomic spectroscopic techniques for the determination of lead in blood and urine matrices

    NASA Astrophysics Data System (ADS)

    Parsons, Patrick J.; Geraghty, Ciaran; Verostek, Mary Frances

    2001-09-01

    The preparation and validation of a number of clinical reference materials for the determination of lead in blood and urine is described. Four candidate blood lead reference materials (Lots, 047-050), and four candidate urine lead reference materials (Lots, 034, 035, 037 and 038), containing physiologically-bound lead at clinically relevant concentrations, were circulated to up to 21 selected laboratories specializing in this analysis. Results from two interlaboratory studies were used to establish certified values and uncertainty estimates for these reference materials. These data also provided an assessment of current laboratory techniques for the measurement of lead in blood and urine. For the blood lead measurements, four laboratories used electrothermal atomization AAS, three used anodic stripping voltammetry and one used both ETAAS and ICP-MS. For the urine lead measurements, 11 laboratories used ETAAS (most with Zeeman background correction) and 10 used ICP-MS. Certified blood lead concentrations, ±S.D., ranged from 5.9±0.4 μg/dl (0.28±0.02 μmol/l) to 76.0±2.2 μg/dl (3.67±0.11 μmol/l) and urine lead concentrations ranged from 98±5 μg/l (0.47±0.02 μmol/l) to 641±36 μg/l (3.09±0.17 μmol/l). The highest concentration blood lead material was subjected to multiple analyses using ETAAS over an extended time period. The data indicate that more stringent internal quality control practices are necessary to improve long-term precision. While the certification of blood lead materials was accomplished in a manner consistent with established practices, the urine lead materials proved more troublesome, particularly at concentrations above 600 μg/l (2.90 μmol/l).

  3. Development of urine standard reference materials for metabolites of organic chemicals including polycyclic aromatic hydrocarbons, phthalates, phenols, parabens, and volatile organic compounds.

    PubMed

    Schantz, Michele M; Benner, Bruce A; Heckert, N Alan; Sander, Lane C; Sharpless, Katherine E; Vander Pol, Stacy S; Vasquez, Y; Villegas, M; Wise, Stephen A; Alwis, K Udeni; Blount, Benjamin C; Calafat, Antonia M; Li, Zheng; Silva, Manori J; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G; Sjödin, Andreas

    2015-04-01

    Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers' Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants.

  4. Development of urine standard reference materials for metabolites of organic chemicals including polycyclic aromatic hydrocarbons, phthalates, phenols, parabens, and volatile organic compounds

    PubMed Central

    Schantz, Michele M.; Benner, Bruce A.; Heckert, N. Alan; Sander, Lane C.; Sharpless, Katherine E.; Vander Pol, Stacy S.; Vasquez, Y.; Villegas, M.; Wise, Stephen A.; Alwis, K. Udeni; Blount, Benjamin C.; Calafat, Antonia M.; Li, Zheng; Silva, Manori J.; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G.; Sjödin, Andreas

    2016-01-01

    Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers’ Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers’ Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants. PMID:25651899

  5. Application of metabolomics: Focus on the quantification of organic acids in healthy adults

    PubMed Central

    Tsoukalas, Dimitris; Alegakis, Athanasios; Fragkiadaki, Persefoni; Papakonstantinou, Evangelos; Nikitovic, Dragana; Karataraki, Aikaterini; Nosyrev, Alexander E.; Papadakis, Emmanouel G.; Spandidos, Demetrios A.; Drakoulis, Nikolaos; Tsatsakis, Aristides M.

    2017-01-01

    Metabolomics, a 'budding' discipline, may accurately reflect a specific phenotype which is sensitive to genetic and epigenetic interactions. This rapidly evolving field in science has been proposed as a tool for the evaluation of the effects of epigenetic factors, such as nutrition, environment, drug and lifestyle on phenotype. Urine, being sterile, is easy to obtain and as it contains metabolized or non-metabolized products, is a favored study material in the field of metabolomics. Urine organic acids (OAs) reflect the activity of main metabolic pathways and have been used to assess health status, nutritional status, vitamin deficiencies and response to xenobiotics. To date, a limited number of studies have been performed which actually define reference OA values in a healthy population and as reference range for epigenetic influences, and not as a reference to congenital metabolic diseases. The aim of the present study was thus the determination of reference values (RVs) for urine OA in a healthy adult population. Targeted metabolomics analysis of 22 OAs in the urine of 122 healthy adults by gas chromatography-mass spectrometry, was conducted. Percentile distributions of the OA concentrations in urine, as a base for determining the RVs in the respective population sample, were used. No significant differences were detected between female and male individuals. These findings can facilitate the more sensitive determination of OAs in pathological conditions. Therefore, the findings of this study may contribute or add to the information already available on urine metabolite databases, and may thus promote the use of targeted metabolomics for the evaluation of OAs in a clinical setting and for pathophysiological evaluation. However, further studies with well-defined patients groups exhibiting specific symptoms or diseases are warranted in order to discern between normal and pathological values. PMID:28498405

  6. Trace elements in a commercial freeze-dried human urine reference material.

    PubMed

    Veillon, C; Patterson, K Y

    1996-07-01

    A large batch of freeze-dried human urine reference material, Seronorm Trace Elements Urine, Lot 101021, was prepared commercially (Nycomed Pharma AS, Oslo, Norway) for quality control purposes in trace element analysis. Analytes are being determined by a voluntary, international co-operative effort so that the material will be available to the scientific community at modest cost. The material is in stoppered glass vials and is to be reconstituted with 5.00 ml of water prior to use. We have evaluated the trace element content for several elements, including chromium and zinc, elements for which we have two independent methods available for the determinations, namely isotope dilution mass spectrometry (IDMS) and atomic absorption spectrometry (AAS). We also report on other trace elements measured by IDMS alone, such as Se, for which we have enriched stable isotopes available. Results for chromium indicate a mean +/- standard deviation (n = 10) of 1.2 +/- 0.3 (by IDMS) and 1.4 +/- 0.3 (by AAS) ng Cr per ml of reconstituted urine, indicating possible inhomogeneity and/or contamination (21-25% relative standard deviation, RSD). Approximately half of the observed chromium originates from the sample container. The values observed for zinc were 590 +/- 90 ng ml-1 (15% RSD) for freshly reconstituted material, 760 +/- 60 ng ml-1 (8% RSD) for material reconstituted 4 d earlier, and 940 +/- 60 ng ml-1 (6% RSD) 2 months after reconstitution. Selenium values by IDMS were very reproducible, with a mean concentration of 16 +/- 0.15 ng g-1 (0.9% RSD), suggesting little or no contamination and a high degree of sample homogeneity for this element. The source of potential contaminants has been evaluated by multielement determinations of leachates of the vials and stoppers. Elements noted in significant amounts include B, Ba, Sr, Mo, Cu and Zn, with most of the zinc coming from the rubber stopper.

  7. Evaluation of a tunable bandpass reaction cell inductively coupled plasma mass spectrometer for the determination of selenium in serum and urine

    NASA Astrophysics Data System (ADS)

    Nixon, David E.; Neubauer, Kenneth R.; Eckdahl, Steven J.; Butz, John A.; Burritt, Mary F.

    2003-01-01

    A Dynamic Reaction Cell™ inductively coupled plasma mass spectrometer (DRC-ICP-MS) was evaluated for the determination of selenium in serum and urine. Reaction cell conditions were evaluated for the suppression of Ar 2+ dimer at m/ z 78 and 80 using methane as the reaction gas. A diluent containing 10% ethanol, 1% nitric acid, 0.5% Triton X-100 with gallium and yttrium internal standards was used to dilute urine and serum samples. Instrument response calibration was achieved by using aqueous acidic standards spiked into a urine matrix. Slopes for aqueous inorganic selenium, seleno- DL-cystine, seleno- DL-methionine and trimethylselenonium iodide spiked into urine and serum matrices were nearly identical. In general, reagent blank readings and detection limits were significantly lower in the DRC mode (reaction cell pressurized) than the standard mode (cell vented). Average results for the analysis of National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1598 bovine serum (attained over 13 days) are: 43.8±3.6 μg Se/l. Reference concentration is 43.6±3.6 μg Se/l. For NIST SRM 2670 Normal Urine the DRC-ICP-MS results are 30.7±4.6 μg Se/l with a certified concentration of 30±8 μg Se/l. For NIST SRM 2670 Elevated Urine the DRC-ICP-MS results are 463±35 μg Se/l with a certified concentration of 460±30 μg Se/l. The DRC-ICP-MS results for selenium determinations in urine and serum survey samples from the Institut National de Sante Publique du Quebec were compared with the reference concentrations and results produced by conventional ICP-MS. While conventional ICP-MS gave acceptable results for survey samples, DRC-ICP-MS gave excellent results for both urine and sera. Closer correlation was observed for DRC-ICP-MS results with target concentrations than with conventional ICP-MS.

  8. Automated color classification of urine dipstick image in urine examination

    NASA Astrophysics Data System (ADS)

    Rahmat, R. F.; Royananda; Muchtar, M. A.; Taqiuddin, R.; Adnan, S.; Anugrahwaty, R.; Budiarto, R.

    2018-03-01

    Urine examination using urine dipstick has long been used to determine the health status of a person. The economical and convenient use of urine dipstick is one of the reasons urine dipstick is still used to check people health status. The real-life implementation of urine dipstick is done manually, in general, that is by comparing it with the reference color visually. This resulted perception differences in the color reading of the examination results. In this research, authors used a scanner to obtain the urine dipstick color image. The use of scanner can be one of the solutions in reading the result of urine dipstick because the light produced is consistent. A method is required to overcome the problems of urine dipstick color matching and the test reference color that have been conducted manually. The method proposed by authors is Euclidean Distance, Otsu along with RGB color feature extraction method to match the colors on the urine dipstick with the standard reference color of urine examination. The result shows that the proposed approach was able to classify the colors on a urine dipstick with an accuracy of 95.45%. The accuracy of color classification on urine dipstick against the standard reference color is influenced by the level of scanner resolution used, the higher the scanner resolution level, the higher the accuracy.

  9. Reference intervals for 24 laboratory parameters determined in 24-hour urine collections.

    PubMed

    Curcio, Raffaele; Stettler, Helen; Suter, Paolo M; Aksözen, Jasmin Barman; Saleh, Lanja; Spanaus, Katharina; Bochud, Murielle; Minder, Elisabeth; von Eckardstein, Arnold

    2016-01-01

    Reference intervals for many laboratory parameters determined in 24-h urine collections are either not publicly available or based on small numbers, not sex specific or not from a representative sample. Osmolality and concentrations or enzymatic activities of sodium, potassium, chloride, glucose, creatinine, citrate, cortisol, pancreatic α-amylase, total protein, albumin, transferrin, immunoglobulin G, α1-microglobulin, α2-macroglobulin, as well as porphyrins and their precursors (δ-aminolevulinic acid and porphobilinogen) were determined in 241 24-h urine samples of a population-based cohort of asymptomatic adults (121 men and 120 women). For 16 of these 24 parameters creatinine-normalized ratios were calculated based on 24-h urine creatinine. The reference intervals for these parameters were calculated according to the CLSI C28-A3 statistical guidelines. By contrast to most published reference intervals, which do not stratify for sex, reference intervals of 12 of 24 laboratory parameters in 24-h urine collections and of eight of 16 parameters as creatinine-normalized ratios differed significantly between men and women. For six parameters calculated as 24-h urine excretion and four parameters calculated as creatinine-normalized ratios no reference intervals had been published before. For some parameters we found significant and relevant deviations from previously reported reference intervals, most notably for 24-h urine cortisol in women. Ten 24-h urine parameters showed weak or moderate sex-specific correlations with age. By applying up-to-date analytical methods and clinical chemistry analyzers to 24-h urine collections from a large population-based cohort we provide as yet the most comprehensive set of sex-specific reference intervals calculated according to CLSI guidelines for parameters determined in 24-h urine collections.

  10. Practical and quality-control aspects of multi-element analysis with quadrupole ICP-MS with special attention to urine and whole blood.

    PubMed

    De Boer, Jan L M; Ritsema, Rob; Piso, Sjoerd; Van Staden, Hans; Van Den Beld, Wilbert

    2004-07-01

    Two screening methods were developed for rapid analysis of a great number of urine and blood samples within the framework of an exposure check of the population after a firework explosion. A total of 56 elements was measured including major elements. Sample preparation consisted of simple dilution. Extensive quality controls were applied including element addition and the use of certified reference materials. Relevant results at levels similar to those found in the literature were obtained for Co, Ni, Cu, Zn, Sr, Cd, Sn, Sb, Ba, Tl, and Pb in urine and for the same elements except Ni, Sn, Sb, and Ba in blood. However, quadrupole ICP-MS has limitations, mainly related to spectral interferences, for the analysis of urine and blood, and these cause higher detection limits. The general aspects discussed in the paper give it wider applicability than just for analysis of blood and urine-it can for example be used in environmental analysis.

  11. The importance of reference materials in doping-control analysis.

    PubMed

    Mackay, Lindsey G; Kazlauskas, Rymantas

    2011-08-01

    Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.

  12. A prospective evaluation of conventional cystography for detection of urine leakage at the vesicourethral anastomosis site after radical prostatectomy based on computed tomography.

    PubMed

    Han, K S; Choi, H J; Jung, D C; Park, S; Cho, K S; Joung, J Y; Seo, H K; Chung, J; Lee, K H

    2011-03-01

    To evaluate the diagnostic accuracy of conventional cystography for the detection of urine leakage at the vesicourethral anastomosis (VUA) site after radical prostatectomy based on computed tomography (CT) cystography. Patients who underwent radical prostatectomies at a single tertiary cancer centre were prospectively enrolled. Conventional cystography was routinely performed on postoperative day 7. Non-enhanced pelvic CT images were obtained after retrograde instillation of the same contrast material for a reference standard of urine leakage at the VUA site. Urine leakage was classified as follows: none; a plication abnormality; mild; moderate; and excessive. One hundred and twenty consecutive patients were enrolled. Conventional cystography detected 14 urine leakages, but CT cystography detected 40 urine leakages, which consisted of 28 mild and 12 moderate urine leakages. When using CT cystography as the standard measurement, conventional cystography showed a diagnostic accuracy of 17.8% (5/28) for mild urine leakage and 75% (9/12) for moderate leakage. Of nine patients diagnosed with mild leakage on conventional cystography, four (44.4%) had complicated moderate urine leakages based on CT cystography, requiring prolonged catheterization. The sensitivity, specificity, positive and negative predictive values, and accuracy of conventional cystography were 35, 100, 100, 75.4, and 78.3%, respectively. Conventional cystography is less accurate than CT cystography for diagnosing urine leakage at the VUA site after a radical prostatectomy. The present results suggest that CT cystography is a good choice for diagnostic imaging of urine leakage after radical prostatectomy. Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...

  14. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...

  15. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...

  16. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...

  17. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...

  18. Stability studies of amphetamine and ephedrine derivatives in urine.

    PubMed

    Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R

    2006-10-20

    Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.

  19. 49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...

  20. 49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...

  1. 49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...

  2. 49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...

  3. 49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...

  4. Evaluation of a tunable bandpass reaction cell for an inductively coupled plasma mass spectrometer for the determination of chromium and vanadium in serum and urine

    NASA Astrophysics Data System (ADS)

    Nixon, David E.; Neubauer, Kenneth R.; Eckdahl, Steven J.; Butz, John A.; Burritt, Mary F.

    2002-05-01

    A Dynamic Reaction Cell™ inductively coupled argon plasma mass spectrometer (DRC-ICP-MS) was evaluated for the determination of chromium and vanadium in serum and urine. Reaction cell conditions were evaluated for the elimination of ArC + and ClOH + interferences on chromium at mass 52 and OCl + on vanadium at mass 51. A diluent containing only 1% nitric acid and internal standards (Y and Ga) was used to prepare serum and urine for analysis. Instrument response calibration was achieved by using aqueous acidic standards spiked into pooled sera or urine matrices. The slopes of the calibration curves prepared in urine and serum matrices were nearly identical. On average, chromium detection limits are 2.5 times lower using the DRC than Zeeman graphite furnace atomic absorption spectrometry (ZGFAAS). Vanadium detection limits are approximately 50 times lower. Average detection limits achieved with DRC-ICP-MS are 0.075 μg Cr/l and 0.028 μg V/l. Average results for the analysis of National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1598 Bovine Serum (attained over 22 days) are: 0.14 μg Cr/l and 0.068 μg V/l. The reference concentrations for vanadium and chromium in NIST SRM 1598 are (0.06) μg V/l and 0.14±0.08 μg Cr/l, respectively. Results for chromium and vanadium determinations on ICP-MS survey samples from the Toxocologie du Quebec are equivalent to those reported by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for the same survey samples.

  5. The comparability of oxalate excretion and oxalate:creatinine ratio in the investigation of primary hyperoxaluria: review of data from a referral centre.

    PubMed

    Clifford-Mobley, Oliver; Tims, Christopher; Rumsby, Gill

    2015-01-01

    Urine oxalate measurement is an important investigation in the evaluation of renal stone disease. Primary hyperoxaluria (PH) is a rare inherited metabolic disease characterised by persistently elevated urine oxalate, but the diagnosis may be missed in adults until renal failure has developed. Urine oxalate results were reviewed to compare oxalate:creatinine ratio and oxalate excretion, and to estimate the potential numbers of undiagnosed PH. Urine oxalate results from August 2011 to April 2013 were reviewed. Oxalate excretion and oxalate:creatinine ratio were evaluated for 24 h collections and ratio alone for spot urine samples. Oxalate:creatinine ratio and oxalate excretion were moderately correlated (R=0.63) in 24-h urine collections from patients aged 18 years and above. Sex-related differences were found requiring implementation of male and female reference ranges for oxalate:creatinine ratio. Of samples with both ratio and excretion above the reference range, 7% came from patients with confirmed PH. There were 24 patients with grossly elevated urine oxalate who had not been evaluated for PH. Oxalate:creatinine ratio and oxalate excretion were discordant in many patients, which is likely to be a result of intra-individual variation in creatinine output and imprecision in the collection itself. Some PH patients had urine oxalate within the reference range on occasion, and therefore it is not possible to exclude PH on the finding of a single normal result. A significant number of individuals had urine oxalate results well above the reference range who potentially have undiagnosed PH and are consequently at risk of renal failure. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  6. Comparison of osmolality and refractometric readings of Hispaniolan Amazon parrot (Amazona ventralis) urine.

    PubMed

    Brock, A Paige; Grunkemeyer, Vanessa L; Fry, Michael M; Hall, James S; Bartges, Joseph W

    2013-12-01

    To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.

  7. URINE SOURCE SEPARATION AND TREATMENT: NUTRIENT RECOVERY USING LOW-COST MATERIALS

    EPA Science Inventory

    Successful completion of this P3 Project will achieve the following expected outputs: identification of low-cost materials that can effectively recover ammonium, phosphate, and potassium from urine; material balance calculations for different urine separation and treatment scheme...

  8. Clinical accuracy of point-of-care urine culture in general practice.

    PubMed

    Holm, Anne; Cordoba, Gloria; Sørensen, Tina Møller; Jessen, Lisbeth Rem; Frimodt-Møller, Niels; Siersma, Volkert; Bjerrum, Lars

    2017-06-01

    To assess the clinical accuracy (sensitivity (SEN), specificity (SPE), positive predictive value and negative predictive value) of two point-of-care (POC) urine culture tests for the identification of urinary tract infection (UTI) in general practice. Prospective diagnostic accuracy study comparing two index tests (Flexicult™ SSI-Urinary Kit or ID Flexicult™) with a reference standard (urine culture performed in the microbiological department). General practice in the Copenhagen area patients. Adult female patients consulting their general practitioner with suspected uncomplicated, symptomatic UTI. (1) Overall accuracy of POC urine culture in general practice. (2) Individual accuracy of each of the two POC tests in this study. (3) Accuracy of POC urine culture in general practice with enterococci excluded, since enterococci are known to multiply in boric acid used for transportation for the reference standard. (4) Accuracy based on expert reading of photographs of POC urine cultures performed in general practice. Standard culture performed in the microbiological department was used as reference standard for all four measures. Twenty general practices recruited 341 patients with suspected uncomplicated UTI. The overall agreement between index test and reference was 0.76 (CI: 0.71-0.80), SEN 0.88 (CI: 0.83-0.92) and SPE 0.55 (CI: 0.46-0.64). The two POC tests produced similar results individually. Overall agreement with enterococci excluded was 0.82 (0.77-0.86) and agreement between expert readings of photographs and reference results was 0.81 (CI: 0.76-0.85). POC culture used in general practice has high SEN but low SPE. Low SPE could be due to both misinterpretation in general practice and an imperfect reference standard. Registration number: ClinicalTrials.gov NCT02323087.

  9. Determination of 241Am in Urine Using Sector Field Inductively Coupled Plasma Mass Spectrometry (SF-ICP-MS)

    PubMed Central

    Xiao, Ge; Saunders, David; Jones, Robert L.; Caldwell, Kathleen L.

    2016-01-01

    Quantification of 241Am in urine at low levels is important for assessment of individuals’ or populations’ accidental, environmental, or terrorism-related internal contamination, but no convenient, precise method has been established to rapidly determine these low levels. Here we report a new analytical method to measure 241Am as developed and validated at the Centers for Disease Control and Prevention (CDC) by means of the selective retention of Am from urine directly on DGA resin, followed by SF-ICP-MS detection. The method provides rapid results with a Limit of Detection (LOD) of 0.22 pg/L (0.028 Bq/L), which is lower than 1/3 of the C/P CDG for 241Am at 5 days post-exposure. The results obtained by this method closely agree with CDC values as measured by Liquid Scintillation Counting, and with National Institute of Standards Technology (NIST) Certified Reference Materials (CRM) target values. PMID:27375308

  10. Determination of 241Am in Urine Using Sector Field Inductively Coupled Plasma Mass Spectrometry (SF-ICP-MS).

    PubMed

    Xiao, Ge; Saunders, David; Jones, Robert L; Caldwell, Kathleen L

    2016-07-01

    Quantification of 241 Am in urine at low levels is important for assessment of individuals' or populations' accidental, environmental, or terrorism-related internal contamination, but no convenient, precise method has been established to rapidly determine these low levels. Here we report a new analytical method to measure 241 Am as developed and validated at the Centers for Disease Control and Prevention (CDC) by means of the selective retention of Am from urine directly on DGA resin, followed by SF-ICP-MS detection. The method provides rapid results with a Limit of Detection (LOD) of 0.22 pg/L (0.028 Bq/L), which is lower than 1/3 of the C/P CDG for 241 Am at 5 days post-exposure. The results obtained by this method closely agree with CDC values as measured by Liquid Scintillation Counting, and with National Institute of Standards Technology (NIST) Certified Reference Materials (CRM) target values.

  11. Compatibility Testing of Non-Metallic Materials for the Urine Processor Assembly (UPA) of International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)

    2001-01-01

    In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA). The urine is distilled, with the concentrated form containing about 15% brine solids, and the dilute form as a blend of pre-treated urine/wastewater. Eighteen candidate non-metallic materials for use with the UPA were tested in 2000 for compatibility with the concentrated and dilute urine solutions for continuous times of at least 30 days, and at conditions of 0.5 psia pressure and 100 F, to simulate the working UPA environment. A primary screening test for each material (virgin and conditioned) was dynamic mechanical analysis (DMA) in the stress relaxation mode, with the test data used to predict material performance for a 10-year use in space. Data showed that most of the candidate materials passed the compatibility testing, although a few significant changes in stress relaxation modulus were observed.

  12. Natural calcium isotonic composition of urine as a marker of bone mineral balance

    USGS Publications Warehouse

    Skulan, J.; Bullen, T.; Anbar, A.D.; Puzas, J.E.; Shackelford, L.; LeBlanc, A.; Smith, S.M.

    2007-01-01

    Background: We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Methods: Calcium isotopic compositions are expressed as ??44Ca, or the difference in parts per thousand between the 44Ca/40Ca of a sample and the 44Ca/ 40Ca of a standard reference material. ??44Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Results: Urine ??44Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, Mest). Results were consistent with the model and with biochemical and bone mineral density data. Conclusion: Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool. ?? 2007 American Association for Clinical Chemistry.

  13. Natural calcium isotopic composition of urine as a marker of bone mineral balance.

    PubMed

    Skulan, Joseph; Bullen, Thomas; Anbar, Ariel D; Puzas, J Edward; Shackelford, Linda; LeBlanc, Adrian; Smith, Scott M

    2007-06-01

    We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Calcium isotopic compositions are expressed as delta(44)Ca, or the difference in parts per thousand between the (44)Ca/(40)Ca of a sample and the (44)Ca/(40)Ca of a standard reference material. delta(44)Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Urine delta(44)Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, t-test). Results were consistent with the model and with biochemical and bone mineral density data. Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool.

  14. The association between a low urine pH and the components of metabolic syndrome in the Korean population: Findings based on the 2010 Korea National health and nutrition examination survey

    PubMed Central

    Cho, Young Hye; Lee, Sang Yeoup; Jeong, Dong Wook; Choi, Eun Jung; Nam, Kyung Jee; Kim, Yun Jin; Lee, Jeong Gyu; Yi, Yu Hyone; Tak, Young Jin; Cho, Byung Mann; Lee, Soo Bong; Lee, Ka Young

    2014-01-01

    Background: Low urine pH is related to obesity and insulin resistance, which are components of metabolic syndrome (MS). The aim of this study was to identify the relation between a low urine pH and MS after controlled for other covariates including demographic and lifestyle factors in adult Korean population. Materials and Methods: We analyzed data from the 2010 Korea National Health and Nutrition Examination Survey, a cross-sectional and nationally representative survey and 1960 men and 2702 women were included in this study. Study subjects were divided into the group with urine pH <5.5 and the group with urine pH ≥5.5 refer to literature. We then evaluated the association between low urine pH and MS. Results: After adjusting for age, sex, smoking status, drinking status, regular exercise, and blood urea nitrogen level, the odds ratio (OR) for the presence of MS in the group with urine pH <5.5 was 1.350 (95% confidence interval [95% CI]: 1.158-1.573) using the American Heart Association/National Heart, Lung, and Blood Institute criteria or 1.304 (95% CI: 1.082-1.572) using the International Diabetes Federation criteria. Among MS components, elevated fasting glucose (OR: 1.231, 95% CI: 1.058-1.433, P = 0.007) and elevated triglyceride (TG) (OR: 1.389, 95% CI: 1.189-1.623, P < 0.001) showed a significantly high OR. Conclusion: The findings confirmed that low urine pH is associated with MS in the Korean population. Among MS components, elevated fasting glucose and elevated TG showed a significantly high OR. PMID:25364357

  15. Smartphone-Based Point-of-Care Urinalysis Under Variable Illumination

    PubMed Central

    Ra, Moonsoo; Lim, Chiawei; Han, Sehui; Jung, Chansung; Kim, Whoi-Yul

    2018-01-01

    Urine tests are performed by using an off-the-shelf reference sheet to compare the color of test strips. However, the tabular representation is difficult to use and more prone to visual errors, especially when the reference color-swatches to be compared are spatially apart. Thus, making it is difficult to distinguish between the subtle differences of shades on the reagent pads. This manuscript represents a new arrangement of reference arrays for urine test strips (urinalysis). Reference color swatches are grouped in a doughnut chart, surrounding each reagent pad on the strip. The urine test can be evaluated using naked eye by referring to the strip with no additional sheet necessary. Along with this new strip, an algorithm for smartphone based application is also proposed as an alternative to deliver diagnostic results. The proposed colorimetric detection method evaluates the captured image of the strip, under various color spaces and evaluates ten different tests for urine. Thus, the proposed system can deliver results on the spot using both naked eye and smartphone. The proposed scheme delivered accurate results under various environmental illumination conditions without any calibration requirements, exhibiting performances suitable for real-life applications and an ease for a common user. PMID:29333352

  16. [Assessment of dietary intake and urinary excretion of sodium and potassium in adults].

    PubMed

    Cornejo, Karen; Pizarro, Fernando; Atalah, Eduardo; Galgani, José E

    2014-06-01

    Hypertension is associated with elevated sodium and low potassium intakes. The determination of sodium and potassium intake by dietary records is inaccurate, being its measurement from 24-h urine collection the reference method. To determine urinary sodium and potassium excretion in adults. To compare dietary sodium and potassium intake and their excretion from an isolated urine sample against the reference method. Seventy healthy adults aged 35 ± 8 years with a body mass index 25 ± 2 kg/m² (36 women) were studied. Urine was collected over 24 h, including an isolated urine sample taken in fasting conditions. Additionally, three 24-h dietary records were performed. Reported sodium and potassium intake was 2,720 ± 567 and 1,068 ± 433 mg/day, respectively. In turn, urinary excretion of sodium and potassium was 4,770 ± 1,532 and 1,852 ± 559 mg/day, respectively. These latter values were significantly higher than those obtained by dietary records. Furthermore, the urinary sodium and potassium excretion estimated from an isolated urine sample was 4,839 ± 1,355 and 1,845 ± 494 mg/day, respectively. These values were similar to those obtained with a 24 h urine collection. Dietary records underestimated electrolyte intake when compared with the reference method. Using an isolated urine sample to estimate electrolyte intake may be a reliable alternative.

  17. PBG urine test

    MedlinePlus

    ... test. Alternative Names Porphobilinogen test; Porphyria - urine; PBG Images Male urinary system References Fuller SJ, Wiley JS. Heme biosynthesis and its disorders: porphyrias and sideroblastic ...

  18. Albumin adsorption onto surfaces of urine collection and analysis containers☆

    PubMed Central

    Robinson, Mary K.; Caudill, Samuel P.; Koch, David D.; Ritchie, James; Hortin, Glen; Eckfeldt, John H.; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W. Greg

    2017-01-01

    Background Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods We added 125I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results Adsorption of urine albumin (UA) at 5–6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH 8 than pH 5 but only 3 cases had p <0.05. Adsorption from 11 unaltered urine samples with albumin 5–333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2 l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2–28%) was larger than that from urine. Conclusions Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. PMID:24513540

  19. Albumin adsorption onto surfaces of urine collection and analysis containers.

    PubMed

    Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg

    2014-04-20

    Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Combined chemical and biotechnological production of 20βOH-NorDHCMT, a long-term metabolite of Oral-Turinabol (DHCMT).

    PubMed

    Liu, Jiaxin; Chen, Lei; Joseph, Jan Felix; Naß, Alexandra; Stoll, Anna; de la Torre, Xavier; Botrè, Francesco; Wolber, Gerhard; Parr, Maria Kristina; Bureik, Matthias

    2018-06-01

    Anabolic androgenic steroids (AAS) are misused very frequently in sport competitions as performance enhancing agents. One of the doping compounds that has been detected with increased frequency in the last few years is dehydrochloromethyltestosterone (DHCMT, 4-chloro-17β-hydroxy-17α-methylandrosta-1,4-dien-3-one; brand name Oral Turinabol). The long-term DHCMT metabolite 20βOH-NorDHCMT (4-chloro-17β-hydroxymethyl-17α-methyl-18-norandrosta-1,4,13-trien-3-one) was reported earlier to be detectable in urine samples for more than 22 days after DHCMT administration; however, purified reference material was not available so far. In this study we demonstrate a successful combination of Wagner-Meerwein rearrangement of DHCMT to NorDHCMT (4-chloro-17,17-dimethyl-18-norandrosta-1,4,13-trien-3-one) and subsequent whole-cell biotransformation with a recombinant fission yeast strain expressing the human cytochrome P450 enzyme (CYP or P450) CYP21A2 for the synthesis of mg amounts of this metabolite. It was then used as reference for the analysis of a post administration urine of DHCMT. The availability of this reference compound will provide an incontestable proof for DHCMT abuse. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. The Human Urine Metabolome

    PubMed Central

    Bouatra, Souhaila; Aziat, Farid; Mandal, Rupasri; Guo, An Chi; Wilson, Michael R.; Knox, Craig; Bjorndahl, Trent C.; Krishnamurthy, Ramanarayan; Saleem, Fozia; Liu, Philip; Dame, Zerihun T.; Poelzer, Jenna; Huynh, Jessica; Yallou, Faizath S.; Psychogios, Nick; Dong, Edison; Bogumil, Ralf; Roehring, Cornelia; Wishart, David S.

    2013-01-01

    Urine has long been a “favored” biofluid among metabolomics researchers. It is sterile, easy-to-obtain in large volumes, largely free from interfering proteins or lipids and chemically complex. However, this chemical complexity has also made urine a particularly difficult substrate to fully understand. As a biological waste material, urine typically contains metabolic breakdown products from a wide range of foods, drinks, drugs, environmental contaminants, endogenous waste metabolites and bacterial by-products. Many of these compounds are poorly characterized and poorly understood. In an effort to improve our understanding of this biofluid we have undertaken a comprehensive, quantitative, metabolome-wide characterization of human urine. This involved both computer-aided literature mining and comprehensive, quantitative experimental assessment/validation. The experimental portion employed NMR spectroscopy, gas chromatography mass spectrometry (GC-MS), direct flow injection mass spectrometry (DFI/LC-MS/MS), inductively coupled plasma mass spectrometry (ICP-MS) and high performance liquid chromatography (HPLC) experiments performed on multiple human urine samples. This multi-platform metabolomic analysis allowed us to identify 445 and quantify 378 unique urine metabolites or metabolite species. The different analytical platforms were able to identify (quantify) a total of: 209 (209) by NMR, 179 (85) by GC-MS, 127 (127) by DFI/LC-MS/MS, 40 (40) by ICP-MS and 10 (10) by HPLC. Our use of multiple metabolomics platforms and technologies allowed us to identify several previously unknown urine metabolites and to substantially enhance the level of metabolome coverage. It also allowed us to critically assess the relative strengths and weaknesses of different platforms or technologies. The literature review led to the identification and annotation of another 2206 urinary compounds and was used to help guide the subsequent experimental studies. An online database containing the complete set of 2651 confirmed human urine metabolite species, their structures (3079 in total), concentrations, related literature references and links to their known disease associations are freely available at http://www.urinemetabolome.ca. PMID:24023812

  2. Animal urine as painting materials in African rock art revealed by cluster ToF-SIMS mass spectrometry imaging.

    PubMed

    Mazel, Vincent; Richardin, Pascale; Touboul, David; Brunelle, Alain; Richard, Caroline; Laval, Eric; Walter, Philippe; Laprévote, Olivier

    2010-08-01

    The rock art site at the village of Songo in Mali is a very important Dogon ritual place where, since the end of the nineteenth century until today, takes place the ceremony of circumcision. During these ceremonies, paintings are performed on the walls of the shelter with mainly three colors: red, black and white. Ethnological literature mentions the use of animal urine of different species such as birds, lizards or snakes as a white pigment. Urine of these animals is mainly composed of uric acid or urate salts. In this article, time-of-flight secondary ion mass spectrometry (ToF-SIMS) is used to compare uric acid, snake urine and a sample of a white pigment of a Dogon painting coming from the rock art site of Songo. ToF-SIMS measurements in both positive and negative ion modes on reference compounds and snake urine proved useful for the study of uric acid and urate salts. This method enables to identify unambiguously these compounds owing to the detection in negative ion mode of the ion corresponding to the deprotonated molecule ([M-H](-) at m/z 167.01) and its fragment ions. Moreover, the mass spectra obtained in positive ion mode permit to differentiate uric acid and urate salts on the basis of specific ions. Applying this method to the Dogon white pigments sample, we show that the sample is entirely composed of uric acid. This proves for the first time, that animal urine was used as a pigment by the Dogon. The presence of uric acid instead of urate salts as normally expected in animal urine could be explained by the preparation of the pigment for its application on the stone. Copyright 2010 John Wiley & Sons, Ltd.

  3. [Drug consumption in diabetes mellitus (IV). The utilization of reactive material and systems for assessing blood glucose control from the viewpoint of primary care. The Group for the Study of Diabetes in Tarragona (GEDT)].

    PubMed

    Costa, B; Huguet, M

    1994-03-12

    A study was performed to analyze the use of reactive material in the periodic follow up of diabetes. Likewise, the use of systems to assess glycemic control by primary care physicians was investigated. Analysis of the habits of use of reactive material was performed on the diabetic population of Tarragona (548,900 inhabitants) by randomized survey of prescription in 525 patients attended in 12 primary care centers. The estimation of amount was carried out by a counting of the public prescriptions made. Similarly the periodicity and the results of the applications of glucoproteins in the reference laboratories were studied. A total of 253 diabetics (48%) were exclusively attended in the centers and 272 (52%) performed some type of home self-analysis; 26 (5%) in urine samples, and 246 (47%) in capillary blood. The estimated mean consumption was of 14 blood sugar strips per patient per month (168 strips/year) and 2.7 glucosuria-glucocetonuria strips (32.4 strips/year). The relative urine/blood ratio was 1/5.2. In 343 cases (65%) some glucoprotein measurement was reported within the last year, 330 (63%) corresponding to glucohemoglobin A1. The mean value was 8.3% (normal: 5-8%). The mean number of applications was 1.6 applications per patient per year. An enormous increase was observed in the amount consumed at the province of reactive material in blood and in the measurement of glucoproteins as the system to assess carbohydrate control in diabetes. A significant reduction was found in the use of reactive strips in urine by the diabetic population.

  4. A new method for quasi-reagent-free biomonitoring of mercury in human urine.

    PubMed

    Schlathauer, Maria; Reitsam, Verena; Schierl, Rudolf; Leopold, Kerstin

    2017-05-01

    A novel analytical method for sampling and extraction of mercury (Hg) from human urine is presented in this work. The method is based on selective accumulation and separation of Hg from fresh urine sample onto active nanogold-coated silica material by highly efficient solid-phase extraction. After thermal desorption of Hg from the extractant, detection is performed by atomic fluorescence spectrometry (AFS). The feasibility and validity of the optimized, quasi-reagent-free approach was confirmed by recovery experiments in spiked real urine (recovery rate 96.13 ± 5.34%) and by comparison of found Hg concentrations in real urine samples - originating from occupationally exposed persons - with values obtained from reference methods cold vapor - atomic absorption spectrometry (CVAAS) and cold vapor - atomic fluorescence spectrometry (CV-AFS). A very good agreement of the found values reveals the validity of the proposed approach. The limit of detection (LOD) was found to be as low as 0.004 μg Hg L -1 and a high reproducibility with a relative standard deviations ≤4.2% (n = 6) is given. Moreover, storage of the samples for up to one week at an ambient temperature of 30 °C reveals no analyte losses or contamination. In conclusion, the proposed method enables easy-to-handle on-site extraction of total Hg from human urine ensuring at the same time reagent-free sample stabilization, providing quick and safe sampling, which can be performed by untrained persons. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Bilirubin - urine

    MedlinePlus

    ... Direct bilirubin - urine Images Male urinary system References Berk PD, Korenblat KM. Approach to the patient with ... Review Date 5/21/2017 Updated by: Laura J. Martin, MD, MPH, ABIM Board Certified in Internal ...

  6. Strategies for improving the collection of 24-hour urine for analysis in the clinical laboratory: redesigned instructions, opinion surveys, and application of reference change value to micturition.

    PubMed

    Tormo, Consuelo; Lumbreras, Blanca; Santos, Ana; Romero, Luis; Conca, Minerva

    2009-12-01

    -The preanalytic phase of 24-hour urine collection, before clinical analysis, requires the active participation of patients and usually takes place outside the laboratory. -We verify whether distribution of adequate information to health care personnel and patients will result in fewer preanalytic incidents. We also determine the intraindividual biologic variability associated with micturition and the corresponding reference change value (RCV). -The intervention provided training for 24-hour urine collection to the health care personnel of the 20th health district of the Valencian community in Spain. The preanalytic incidents related to 24-hour micturition were estimated before and after the intervention. An opinion survey on the problems involved in urine collection was also conducted among patients. The Harris formula was used to calculate the RCV. -Before the intervention, 130 preanalytic incidents were recorded (11.5%) and after the intervention, 76 (8.6%) (P = .04) were recorded. Of the 130 incidents recorded before the intervention, 63 (48.5%) involved omission to indicate the urine volume, and of the 76 incidents recorded after the intervention, only 1 (1.3%) (P < .001) involved this omission. Forty of 302 patients (13.2%) surveyed reported problems and more than half (175; 57.9%) had to collect various urine samples sequentially. The RCV determined was 54.5% for a percentage of variation in volume of 24-hour urine (PVVI) of 19.0 +/- 16.5%. Therefore, micturition associated with a PVVI >+/-54.5% suggests that 24-hour urine collection by the patient was incomplete. The results obtained when applying the RCV after the intervention showed that 6.3% of the 24-hour urine samples should be rejected. -The percentage of preanalytic incidents was reduced by providing health care personnel with information and training. The percentage of variation in volume of 24-hour urine can be used to evaluate the variation in patients' micturition. Reference change value was shown to be useful when determining whether 24-hour urine was properly collected.

  7. Determination of inorganic arsenic and its organic metabolites in urine by flow-injection hydride generation atomic absorption spectrometry.

    PubMed

    Hanna, C P; Tyson, J F; McIntosh, S

    1993-08-01

    A method has been developed for the determination of inorganic arsenic [As(III) and As(V)] and its organic metabolites (monomethylarsenic and dimethylarsenic) in urine by flow-injection hydride generation atomic absorption spectrometry. The nontoxic seafood-derived arsenobetaine and arsenocholine species were first separated by a solid-phase extraction procedure. The remaining sample was digested with a mixture of nitric and sulfuric acids and potassium dichromate, followed by attack with hydrogen peroxide. The resulting As(V) was reduced to As(III) with potassium iodide in hydrochloric acid before injection into the flow-injection manifold. The percentage analytical recoveries (mean +/- 95% confidence interval) of various arsenic species added to a urine specimen at 250 micrograms/L were 108 +/- 2, 112 +/- 11, 104 +/- 7, and 95 +/- 5 for As(III), As(V), monomethylarsenic, and dimethylarsenic, respectively. For the determination of arsenic in Standard Reference Material 2670 (toxic metals in human urine), results agreed with the certified value (480 +/- 100 micrograms/L). Analyses of samples for the Centre de Toxicologie du Quebec, containing seafood-derived species, demonstrated the viability of the separation procedure. Detection limits were between 0.1 and 0.2 microgram/L in the solution injected into the manifold, and precision at 10 micrograms/L was between 2% and 3% (CV). These preliminary results show that the method might be applicable to determinations of arsenic in a range of clinical urine specimens.

  8. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    PubMed

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  9. Factitious diarrhea induced by stimulant laxatives: accuracy of diagnosis by a clinical reference laboratory using thin layer chromatography.

    PubMed

    Shelton, Joseph H; Santa Ana, Carol A; Thompson, Donald R; Emmett, Michael; Fordtran, John S

    2007-01-01

    Surreptitious ingestion of laxatives can lead to serious factitious diseases that are difficult to diagnose. Most cases involve ingestion of bisacodyl or senna. Thin layer chromatography (TLC) of urine or stool is the only commercially available test for these laxatives. Such testing is considered highly reliable, but its accuracy in clinical practice is unknown. Our aim was to evaluate the reliability of TLC laxative testing by a clinical reference laboratory in the United States. Diarrhea was induced in healthy volunteers by ingestion of bisacodyl, senna, or a control laxative (n = 11 for each laxative group). Samples of urine and diarrheal stool were sent in blinded fashion to the clinical reference laboratory for bisacodyl and senna analysis. TLC testing for bisacodyl-induced diarrhea revealed a sensitivity of 73% and specificity of 91% when urine was tested and sensitivity and specificity of 91% and 96%, respectively, when stool was analyzed. When diarrhea was induced by senna, the TLC assay for senna failed to identify even a single urine or stool specimen as positive (zero% sensitivity). Considering the expected prevalence of surreptitious laxative abuse in patients with chronic idiopathic diarrhea (2.4%-25%, depending on the clinical setting), TLC of urine or stool for bisacodyl by this reference laboratory would often produce misleading results, and testing for senna would have no clinical value. The major problems are false-positive tests for bisacodyl and false-negative tests for senna.

  10. Biomonitoring of 33 Elements in Blood and Urine Samples from Coastal Populations in Sanmen County of Zhejiang Province.

    PubMed

    Zhang, Su-jing; Luo, Ru-xin; Ma, Dong; Zhuo, Xian-yi

    2016-04-01

    To determine the normal reference values of 33 elements, Ag, Al, As, Au, B, Ba, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, Hg, Li, Mg, Mn, Mo, Ni, Pb, Rb, Sb, Se, Sr, Th, Ti, Tl, U, V, Zn and Zr, in the blood and urine samples from the general population in Sanmen County of Zhejiang province, a typical coastal area of eastern China. The 33 elements in 272 blood and 300 urine samples were determined by inductively coupled plasma-mass spectrometry (ICP-MS). The normality test of data was conducted using SPSS 17.0 Statistics. The data was compared with other reports. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County were obtained, which of some elements were found to be similar with other reports, such as Co, Cu, Mn and Sr, while As, Cd, Hg and Pb were generally found to be higher than those previously reported. There was a wide variation between the reports from different countries in blood Ba. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County are established, and successfully applied to two poisoning cases.

  11. Compatibility Testing of Polymeric Materials for the Urine Processor Assembly (UPA) of International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    Wingard, Charles D.

    2003-01-01

    In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA) by a distillation process. The urine is pre-treated, containing flush water and stabilizers. About 2.5% solids in the urine are concentrated up to 16% brine through distillation. Dynamic mechanical analysis (DMA) in the stress relaxation mode was primarily used to test 15 polymeric UPA materials for compatibility with the pre-treated and brine solutions. There were concerns that chromium trioxide (CrO3), a stabilizer not in the original pre-treat formulation for similar compatibility testing in 2000, could have an adverse effect on these polymers. DMA testing is partially complete for polymeric material samples immersed in the two solutions at room temperature for as long as 200 days. By comparing each material (conditioned and virgin), the stress relaxation modulus (E) was determined for short-term use and predicted for as long as a 10-year use in space. Such a delta E showed a decrease of as much as 79% for a Nylon material, but an increase as much as 454% for a polysulfone material, with increasing immersion time.

  12. [The role of telomerase activity in non-invasive diagnostics of bladder cancer].

    PubMed

    Glybochko, P V; Alyaev, J G; Potoldykova, N V; Polyakovsky, K A; Vinarov, A Z; Glukhov, A I; Gordeev, S A

    2016-08-01

    To evaluate the potentials of determining the telomerase activity (TA) in the cellular material of the urine for noninvasive diagnosis of bladder cancer (BC). Evaluation of TA was performed in the urine of 48 patients with bladder cancer (study group) before and after transurethral resection of the bladder wall (n=38), an open resection of the bladder (n=4), and cystectomy (n=6). TA was also evaluated in 48 tumor tissue samples obtained from these patients during removal of the bladder tumor. Each sample of the tumor tissue was separated into two parts, one of which was subjected to histological examination, and the latter was used to determine the telomerase activity. In all cases, the diagnosis of bladder cancer was confirmed morphologically. Determination of TA in the samples was performed by the modified TRAP-method (telomerase repeat amplification protocol), RT-PCR, PCR, and electrophoresis. As a control, cell material of the urine and tissue in 12 patients with chronic cystitis was investigated. TA before surgery was found in 45 (93.75%) of 48 samples of cellular material of the urine from patients with suspected bladder cancer. BC was histologically verified in all patients in this group. In the postoperative period, TA was not observed in the 48 samples of cellular material of the urine from patients with BC. In the control group of patients with histologically verified cystitis, weak TA was determined only in one sample of cellular material of the urine. The analysis indicates statistically significant predominance of patients with bladder cancer in case of TA in the urine (P=0.001). TA was detected in all samples of tumor tissue. We also analyzed the dependence of TA levels in urine and tissue on the degree of BC differentiation. In patients with highly differentiated BC, mean AT in the cellular materials of the urine was 0,61% (n=15), in patients with moderately differentiated BC - 0.95% (n=23), in patients with low-grade bladder cancer - 1.33% (n=10); in other words, increase in the TA levels with decreasing the degree of differentiation was observed. This finding can be used in the prognosis of the course of disease based on determining the TA level in these patients. Preliminary data indicate the possibility of use of determining the TA in cellular material of the urine for the diagnosis and monitoring of bladder cancer recurrence.

  13. Genetics Home Reference: cystinuria

    MedlinePlus

    ... a condition characterized by the buildup of the amino acid cystine, a building block of most proteins, in ... properly reabsorb cystine into their bloodstream, so the amino acid accumulates in their urine. As urine becomes more ...

  14. Recommendations for provoked challenge urine testing.

    PubMed

    Ruha, Anne-Michelle

    2013-12-01

    "Urine mobilization test," "challenge test," and "provoked urine test" are all terms used to describe the administration of a chelating agent to a person prior to collection of their urine to test for metals. There is no standard, validated challenge test. Despite recommendations by professional and government organizations against the use of provoked urine testing, the tests are still commonly used and recommended by some practitioners. Challenge testing utilizes a variety of chelating agents, including dimercaptosuccinic acid (DMSA), dimercaptopropanesulfonate (DMPS), and ethylenediaminetetraacetic acid (EDTA). The agents are given by a variety of routes of administration, doses used are inconsistent, and urine collection procedures vary. Additional problems with challenge tests include comparison of results to inappropriate reference ranges and creatinine correction of urine obtained within hours of chelator administration. Human volunteer studies demonstrate that mercury is detected in the urine of most people even in the absence of known exposure or chelator administration, and that urinary mercury excretion rises after administration of a chelator, regardless of exposure history and in an unpredictable fashion. Studies also demonstrate that challenge testing fails to reveal a "body burden" of mercury due to remote exposure. Chelating agents have been associated with adverse reactions. Current evidence does not support the use of DMPS, DMSA, or other chelation challenge tests for the diagnosis of metal toxicity. Since there are no established reference ranges for provoked urine samples in healthy subjects, no reliable evidence to support a diagnostic value for the tests, and potential harm, these tests should not be utilized.

  15. Anthropometry-based 24-h urinary creatinine excretion reference for Chinese children

    PubMed Central

    Wang, Wei; Du, Cong; Lin, Laixiang; Chen, Wen; Tan, Long; Shen, Jun; Pearce, Elizabeth N.; Zhang, Yixin; Gao, Min; Bian, Jianchao; Wang, Xiaoming; Zhang, Wanqi

    2018-01-01

    To establish 24-h urinary creatinine excretion reference ranges based on anthropometry in healthy Chinese children, a cross-sectional survey was conducted using twice-sampled 24-h urine and anthropometric variables. Age- and sex-specific 24-h creatinine excretion reference ranges (crude and related to individual anthropometric variables) were derived. During October 2013 and May 2014, urine samples were collected. Anthropometric variables were measured in the first survey. Data of 710 children (377 boys and 333 girls) aged 8–13 years who completed the study were analyzed. No significant difference was observed in 24-h urine volumes between the two samples (median [interquartile range): 855.0 [600.0–1272.0) mL vs. 900.0 [660.0–1220.0) mL, P = 0.277). The mean 24-h urine creatinine excretion was regarded as representative of absolute daily creatinine excretion in children. Sex-specific, body-weight-adjusted creatinine excretion reference values were 15.3 mg/kg/day (0.1353 mmol/kg/day) for boys and 14.3 mg/kg/day (0.1264 mmol/kg/day) for girls. Differences were significant between boys and girls within the same age group but not across different age groups within the same sex. Ideal 24-h creatinine excretion values for height were derived for potential determination of the creatinine height index. These data can serve as reference ranges to calculate ratios of analyte to creatinine. The creatinine height index can be used to assess somatic protein status. PMID:29791502

  16. Genetics Home Reference: maple syrup urine disease

    MedlinePlus

    ... disease is an inherited disorder in which the body is unable to process certain protein building blocks (amino acids) properly. The condition gets its name from the distinctive sweet odor of affected infants' urine. It is also characterized ...

  17. Longitudinal Urinary Protein Variability in Participants of the Space Flight Simulation Program.

    PubMed

    Khristenko, Nina A; Larina, Irina M; Domon, Bruno

    2016-01-04

    Urine is a valuable material for the diagnosis of renal pathologies and to investigate the effects of their treatment. However, the variability in protein abundance in the context of normal homeostasis remains a major challenge in urinary proteomics. In this study, the analysis of urine samples collected from healthy individuals, rigorously selected to take part in the MARS-500 spaceflight simulation program, provided a unique opportunity to estimate normal concentration ranges for an extended set of urinary proteins. In order to systematically identify and reliably quantify peptides/proteins across a large sample cohort, a targeted mass spectrometry method was developed. The performance of parallel reaction monitoring (PRM) analyses was improved by implementing tight control of the monitoring windows during LC-MS/MS runs, using an on-the-fly correction routine. Matching the experimentally obtained MS/MS spectra with reference fragmentation patterns allowed dependable peptide identifications to be made. Following optimization and evaluation, the targeted method was applied to investigate protein abundance variability in 56 urine samples, collected from six volunteers participating in the MARS-500 program. The intrapersonal protein concentration ranges were determined for each individual and showed unexpectedly high abundance variation, with an average difference of 1 order of magnitude.

  18. Achieving 100% Efficient Postcolumn Hydride Generation for As Speciation Analysis by Atomic Fluorescence Spectrometry.

    PubMed

    Marschner, Karel; Musil, Stanislav; Dědina, Jiří

    2016-04-05

    An experimental setup consisting of a flow injection hydride generator coupled to an atomic fluorescence spectrometer was optimized in order to generate arsanes from tri- and pentavalent inorganic arsenic species (iAs(III), iAs(V)), monomethylarsonic acid (MAs(V)), and dimethylarsinic acid (DMAs(V)) with 100% efficiency with the use of only HCl and NaBH4 as the reagents. The optimal concentration of HCl was 2 mol L(-1); the optimal concentration of NaBH4 was 2.5% (m/v), and the volume of the reaction coil was 8.9 mL. To prevent excessive signal noise due to fluctuations of hydride supply to an atomizer, a new design of a gas-liquid separator was implemented. The optimized experimental setup was subsequently interfaced to HPLC and employed for speciation analysis of arsenic. Two chromatography columns were tested: (i) ion-pair chromatography and (ii) ion exchange chromatography. The latter offered much better results for human urine samples without a need for sample dilution. Due to the equal hydride generation efficiency (and thus the sensitivities) of all As species, a single species standardization by DMAs(V) standard was feasible. The limits of detection for iAs(III), iAs(V), MAs(V), and DMAs(V) were 40, 97, 57, and 55 pg mL(-1), respectively. Accuracy of the method was tested by the analysis of the standard reference material (human urine NIST 2669), and the method was also verified by the comparative analyses of human urine samples collected from five individuals with an independent reference method.

  19. Determination of Cd in urine by cloud point extraction-tungsten coil atomic absorption spectrometry.

    PubMed

    Donati, George L; Pharr, Kathryn E; Calloway, Clifton P; Nóbrega, Joaquim A; Jones, Bradley T

    2008-09-15

    Cadmium concentrations in human urine are typically at or below the 1 microgL(-1) level, so only a handful of techniques may be appropriate for this application. These include sophisticated methods such as graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry. While tungsten coil atomic absorption spectrometry is a simpler and less expensive technique, its practical detection limits often prohibit the detection of Cd in normal urine samples. In addition, the nature of the urine matrix often necessitates accurate background correction techniques, which would add expense and complexity to the tungsten coil instrument. This manuscript describes a cloud point extraction method that reduces matrix interference while preconcentrating Cd by a factor of 15. Ammonium pyrrolidinedithiocarbamate and Triton X-114 are used as complexing agent and surfactant, respectively, in the extraction procedure. Triton X-114 forms an extractant coacervate surfactant-rich phase that is denser than water, so the aqueous supernatant is easily removed leaving the metal-containing surfactant layer intact. A 25 microL aliquot of this preconcentrated sample is placed directly onto the tungsten coil for analysis. The cloud point extraction procedure allows for simple background correction based either on the measurement of absorption at a nearby wavelength, or measurement of absorption at a time in the atomization step immediately prior to the onset of the Cd signal. Seven human urine samples are analyzed by this technique and the results are compared to those found by the inductively coupled plasma mass spectrometry analysis of the same samples performed at a different institution. The limit of detection for Cd in urine is 5 ngL(-1) for cloud point extraction tungsten coil atomic absorption spectrometry. The accuracy of the method is determined with a standard reference material (toxic metals in freeze-dried urine) and the determined values agree with the reported levels at the 95% confidence level.

  20. The ultimate veal calf reference experiment: hormone residue analysis data obtained by gas and liquid chromatography tandem mass spectrometry.

    PubMed

    Nielen, Michel W F; Lasaroms, Johan J P; Essers, Martien L; Sanders, Marieke B; Heskamp, Henri H; Bovee, Toine F H; van Rhijn, J Hans; Groot, Maria J

    2007-03-14

    A lifetime controlled reference experiment has been performed using 42 veal calves, 21 males and 21 females which were fed and housed according to European regulations and common veterinary practice. During the experiment feed, water, urine and hair were sampled and feed intake and growth were monitored. Thus for the first time residue analysis data were obtained from guaranteed lifetime-untreated animals. The analysis was focused on the natural hormones estradiol and testosterone and their metabolites, on 17beta- and 17alpha-nortestosterone, on 17beta- and 17alpha-boldenone and androsta-1,4-diene-3,17-dione (ADD), and carried out by gas chromatography tandem mass spectrometry (GC/MS/MS), an estrogen bioassay and liquid chromatography (LC) MS/MS. Feed, water and hair samples were negative for the residues tested. Female calf urines showed occasionally low levels of 17alpha-estradiol and 17alpha-testosterone. On one particular sampling day male veal calf urines showed very high levels of 17alpha-testosterone (up to 1000 ng mL(-1)), accompanied by lower levels of estrone and 17beta-testosterone. Despite these extreme levels of natural testosterone, 17beta-boldenone was never detected in the same urine samples; even 17alpha-boldenone and ADD were only occasionally beyond CCalpha (maximum levels 2.7 ng mL(-1)). The data from this unique experiment provide a set of reference values for steroid hormones in calf urine and demonstrate that 17beta-boldenone is not a naturally occurring compound in urine samples.

  1. Vanadium release in whole blood, serum and urine of patients implanted with a titanium alloy hip prosthesis.

    PubMed

    Catalani, S; Stea, S; Beraudi, A; Gilberti, M E; Bordini, B; Toni, A; Apostoli, P

    2013-08-01

    Vanadium (V) is a minor constituent of the Titanium-Aluminum-Vanadium (TiAlV) alloy currently used in cementless hip prostheses. Present study aimed at verifying the correlation of vanadium levels among different matrices and assessing reference levels of the ion in a population of patients wearing a well-functioning hip prosthesis. Vanadium was measured using Inductive Coupled Plasma Mass Spectrometry (ICP-MS) in whole blood, serum and urine of 129 patients implanted with a TiAlV-alloy hip prosthesis. The values in the serum were above the upper limit of the reference values in 42% of patients (29% in urine and 13% in whole blood). A good correlation among matrices was observed (p < 0.001). The cohort of patients (N = 32) complaining of pain or in which a loosening or damage to the prosthesis was assessed showed a significantly higher excretion of vanadium in urine as compared with the remaining asymptomatic patients (p = 0.001). The 95th percentile distribution of vanadium in the cohort of patients with a well-functioning prosthesis was 0.3 μg/L in whole blood, 0.5 μg/L in serum and 2.8 μg/L in urine, higher that in the unexposed population, especially for urine. The presence of a prosthesis, even though well-functioning, may cause a possible release of vanadium into the blood and a significant urinary excretion. The reference values of vanadium of the asymptomatic patients with titanium alloy hip prostheses supplied information regarding the background exposure level of the ions and their lower and upper limits.

  2. Temporary Urine and Brine Stowage System (TUBSS) Materials Selection and Testing

    NASA Technical Reports Server (NTRS)

    Carrigan, Caitlin; Dries, Kevin; Pensinger, Stuart

    2011-01-01

    Storing wastewater in the event of a system anomaly is a necessity for closed loop water recovery systems. The temporary urine and brine stowage system (TUBSS) is an assembly used to store and transfer pre-treated urine (PTU) and brine for processing or disposal at a later date. This paper describes the selection and testing of several candidate materials from both a chemical and material strength standpoint. In addition, this paper will provide results of testing as well as lessons learned from the project, culminating in the successful launch of the hardware.

  3. Development of Standard Reference Materials to support assessment of iodine status for nutritional and public health purposes.

    PubMed

    Long, Stephen E; Catron, Brittany L; Boggs, Ashley Sp; Tai, Susan Sc; Wise, Stephen A

    2016-09-01

    The use of urinary iodine as an indicator of iodine status relies in part on the accuracy of the analytical measurement of iodine in urine. Likewise, the use of dietary iodine intake as an indicator of iodine status relies in part on the accuracy of the analytical measurement of iodine in dietary sources, including foods and dietary supplements. Similarly, the use of specific serum biomarkers of thyroid function to screen for both iodine deficiency and iodine excess relies in part on the accuracy of the analytical measurement of those biomarkers. The National Institute of Standards and Technology has been working with the NIH Office of Dietary Supplements for several years to develop higher-order reference measurement procedures and Standard Reference Materials to support the validation of new routine analytical methods for iodine in foods and dietary supplements, for urinary iodine, and for several serum biomarkers of thyroid function including thyroid-stimulating hormone, thyroglobulin, total and free thyroxine, and total and free triiodothyronine. These materials and methods have the potential to improve the assessment of iodine status and thyroid function in observational studies and clinical trials, thereby promoting public health efforts related to iodine nutrition. © 2016 American Society for Nutrition.

  4. Green Urine in Traditional Persian Medicine

    PubMed Central

    Kolouri, Sepideh; Daneshfard, Babak; Jaladat, Amir-Mohammad; Tafazoli, Vahid

    2016-01-01

    The color of urine is an important factor in urine examination, which can help physicians differentiate various diseases. Today, it is known that certain dyes, drug intoxications, and diseases can induce green urine discoloration. In the view of traditional Persian medicine, which is based on humoral medicine, green urine discoloration is generally referred to the dominance of coldness in the body. In fact, it is considered to be a result of a special kind of humoral imbalance and fluid depletion or retention in the human body. Persian scholars believed that green urine could be an indicator of intoxication or a predictor of an imminent spasm or convulsion in pediatric patients. Further investigations could result in finding new diagnostic scales of urine color based on the teachings of traditional Persian medicine. PMID:27103627

  5. The biodistribution and dosimetry of {sup 117m}Sn DTPA with special emphasis on active marrow absorbed doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stubbs, J.; Atkins, H.

    1999-01-01

    {sup 117m}Sn(4+) DTPA is a new radiopharmaceutical for the palliation of pain associated with metastatic bone cancer. Recently, the Phase 2 clinical trials involving 47 patients were completed. These patients received administered activities in the range 6.7--10.6 MBq/kg of body mass. Frequent collections of urine were acquired over the first several hours postadministration and daily cumulative collections were obtained for the next 4--10 days. Anterior/posterior gamma camera images were obtained frequently over the initial 10 days. Radiation dose estimates were calculated for 8 of these patients. Each patient`s biodistribution data were mathematically simulated using a multicompartmental model. The model consistedmore » of the following compartments: central, bone, kidney, other tissues, and cumulative urine. The measured cumulative urine data were used as references for the cumulative urine excretion compartment. The total-body compartment (sum of the bone surfaces, central, kidney, and other tissues compartments) was reference to all activity not excreted in the urine.« less

  6. Plasma free metanephrines are superior to urine and plasma catecholamines and urine catecholamine metabolites for the investigation of phaeochromocytoma.

    PubMed

    Hickman, Peter E; Leong, Michelle; Chang, Julia; Wilson, Susan R; McWhinney, Brett

    2009-02-01

    To compare the relative diagnostic efficacy of several different tests used to establish a diagnosis of phaeochromocytoma, in patients with a proven diagnosis of phaeochromocytoma, and in hospital patients with significant disease of other types. We prospectively compared biochemical markers of catecholamine output and metabolism in plasma and urine in 22 patients with histologically proven phaeochromocytoma, 15 intensive care unit (ICU) patients, 30 patients on chronic haemodialysis and both hypertensive (n = 10) and normotensive (n = 16) controls. Receiver operating characteristic curves were plotted. At the point of maximum efficiency, plasma free metanephrines showed 100% sensitivity and 97.6% specificity, compared with plasma catecholamines (78.6% and 70.7%), urine catecholamines (78.6% and 87.8%), urine metanephrines (85.7% and 95.1%), and urine hydroxymethoxymandelic acid (HMMA or VMA) (93.0% and 75.8%). All patients with phaeochromocytoma had plasma free metanephrine concentrations at least 27% above the upper limit of the reference range. Only three other patients (two on haemodialysis and one in ICU) had PFM concentrations more than 50% above the upper limit of the reference range. In patients with phaeochromocytoma, plasma free metanephrines displayed superior diagnostic sensitivity and specificity compared with other biochemical markers of catecholamine output and metabolism.

  7. KEY COMPARISON: Final report on CCQM-K69 key comparison: Testosterone glucuronide in human urine

    NASA Astrophysics Data System (ADS)

    Liu, Fong-Ha; Mackay, Lindsey; Murby, John

    2010-01-01

    The CCQM-K69 key comparison of testosterone glucuronide in human urine was organized under the auspices of the CCQM Organic Analysis Working Group (OAWG). The National Measurement Institute Australia (NMIA) acted as the coordinating laboratory for the comparison. The samples distributed for the key comparison were prepared at NMIA with funding from the World Anti-Doping Agency (WADA). WADA granted the approval for this material to be used for the intercomparison provided the distribution and handling of the material were strictly controlled. Three national metrology institutes (NMIs)/designated institutes (DIs) developed reference methods and submitted data for the key comparison along with two other laboratories who participated in the parallel pilot study. A good selection of analytical methods and sample workup procedures was displayed in the results submitted considering the complexities of the matrix involved. The comparability of measurement results was successfully demonstrated by the participating NMIs. Only the key comparison data were used to estimate the key comparison reference value (KCRV), using the arithmetic mean approach. The reported expanded uncertainties for results ranged from 3.7% to 6.7% at the 95% level of confidence and all results agreed within the expanded uncertainty of the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Temozolomide

    MedlinePlus

    ... medical treatment: unusual bleeding or bruising red or black, tarry stools pink, red, or dark brown urine coughing up or vomiting blood or material ... the following: unusual bleeding or bruising red or black, tarry stools pink, red, or dark brown urine coughing up or vomiting blood or material ...

  9. Studies on acid-base status (Stewart's model) of young camels (Camelus dromedarius) after acid-load with NH4Cl.

    PubMed

    Elkhair, Nawal M; Hartmann, Helmut

    2010-01-01

    The identification of the reference values of Stewart variables and the changes in the acid-base status of the blood and urine in relation to the age after acid-load were studied in desert species of camels. 14 healthy young camels (age: 3-5 months) and 22 adult camels (age: 5-8 years) were used to provide the reference and percentile ranges of the Stewart variables. In the experiments, 24 healthy young camels (age: < 3-5 months) were infused with 5M NH4Cl solution (dose: 1.0 ml/kg) through a permanent intravenous catheter. Venous blood and urine samples were collected before infusion (0 hours). After the start of infusion, venous blood samples were collected at 2, 4, 6, 8 and 24 hours, and urine samples were collected at 8, 24 and 48 hours. Blood and urine samples were used for the determination of the various acid-base parameters, including the non-respiratory Stewart variables. The reference range of serum-[strong ion difference = SID3] was 39-52 mmol/l for all age groups. The reference values of serum-[acid total = A-] were between 10-17 mmol/l for all age groups. Serum-[Atotprotein] and -[Atot-albumin] showed a reference range of 19-24 mmol/I and 20-28 mmol/l, respectively. By 2-8 hours after the NH4Cl-load, the Stewart variables (serum-[SID3] and serum-[A(tot-protein)]) decreased significantly, and as a consequence, the blood pH decreased. Generally, the loaded young camels showed a transient moderate hyperchloraemic acidosis with a slight hypoproteinaemic alkalosis. These malfunctions were accompanied by increased renal fractional excretion of chloride and sodium and decreased urine pH. The identified reference values of the Stewart variables can be used for the clinical diagnosis of acid-base disturbances in camels. With the assistance of the non-respiratory Stewart variables ([SID3] and [Atot]), we can detect the determining influence of strong electrolytes (Na+, K+ and Cl-) and weak acids (proteins, Pi) on the physiological and pathological acid-base status of the animals.

  10. Evaluation of chromium, cobalt and manganese in biological samples (scalp hair, blood, and urine) of Pakistani viral hepatitis (A-E) patients and controls.

    PubMed

    Afridi, Hassan Imran; Kazi, Tasneem Gul; Kazi, Naveed; Naeemullah; Arain, Sadaf Sadia; Brahman, Kapil Dev; Wadhwa, Sham Kumar

    2013-01-01

    The aim of the present study was to compare the level of chromium (Cr), cobalt (Co), and manganese (Mn) in biological samples (blood, urine, and scalp hair) of patients suffering from different types of viral hepatitis (A, B, C, D, and E; n = 521) of both genders, ages ranging from 31 - 45 years. For comparative study, 255 age-matched control subjects of both genders residing in the same city were selected as referents. The digests of all biological samples were analysed for Cr, Co, and Mn by electrothermal atomic absorption spectrometry (ETAAS). The validity and accuracy of the methodology was checked by using certified reference materials (CRMs) and compared with those values obtained by conventional wet acid digestion method on same CRMs. The results of this study showed that the mean values of Cr, Co, and Mn were higher in blood and scalp hair samples of hepatitis patients than in age-matched control subjects. The urinary levels of these elements were found to be higher in the hepatitis patients than in the age-matched healthy controls (p <0.001). These results are consistent with literature-reported data, confirming that the overload of these trace elements can directly cause lipid peroxidation and eventually hepatic damage.

  11. Temozolomide Injection

    MedlinePlus

    ... medical treatment: unusual bleeding or bruising red or black, tarry stools pink, red, or dark brown urine coughing up or vomiting blood or material ... the following: unusual bleeding or bruising red or black, tarry stools pink, red, or dark brown urine coughing up or vomiting blood or material ...

  12. Supported liquid membrane coupled on-line to potentiometric stripping analysis at a mercury-coated reticulated vitreous carbon electrode for trace metal determinations in urine.

    PubMed

    Djane, N K; Armalis, S; Ndung'u, K; Johansson, G; Mathiasson, L

    1998-02-01

    A method for trace metal determinations in complex matrices is presented. The method combines supported liquid membrane (SLM) sample clean-up and enrichment with potentiometric stripping analysis (PSA) in a flow system using reticulated vitreous carbon (RVC) as the electrode material. The membrane contained 40% m/m di-2-ethylhexylphosphoric acid dissolved in kerosene. Lead was used as a model substance in high-purity water and urine samples. The samples were enriched after a simple pH adjustment. The SLM enrichment time was 10 min when the last 5 min electrodeposition on the RVC electrode at -1.0 V (versus Ag/AgCl) was performed simultaneously. The influence of various experimental parameters such as deposition time, deposition potential and flow rate on the lead signal was investigated. With a 10 min SLM enrichment including a 5 min deposition time, the detection limit for lead was 0.3 microgram l-1. The relative standard deviation for lead concentrations in the range 4-20 micrograms l-1 was 0.05%. The overall SLM-PSA system was found to be stable for at least 100 urine analyses. The method was validated by running a reference urine sample. The result obtained (five replicates) was 9.7 micrograms l-1 (standard deviation 1.8 micrograms l-1) which is within the recommended range of 9.2-10.8 micrograms l-1.

  13. Health status of copper refinery workers with specific reference to selenium exposure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holness, D.L.; Taraschuk, I.G.; Nethercott, J.R.

    1989-09-01

    Copper refinery workers exposed to selenium were studied before, during, and after a shutdown period. Urine selenium levels were 83 {plus minus} 30 mumol/mol creatinine and 69 {plus minus} 27 mumol/mol creatinine when measured on two occasions during exposure compared with 56 {plus minus} 17 mumol/mol creatinine when the workers had been free of exposure for 10 wk during a shutdown. The refinery workers reported more nose and eye irritation, indigestion, stomach pain, and fatigue than controls. Garlic-like breath odor was reported to be personally and socially offensive by many of the workers. Reporting of symptoms, pulmonary function indices, andmore » laboratory test results did not change with exposure except for hemoglobin level, which rose during the shutdown. Hemoglobin levels were found to be inversely correlated with the urine selenium level, and there was a positive correlation noted for the interactive effect of urine selenium and urine arsenic levels on hemoglobin.49 references.« less

  14. The incidence of elevations in urine 5-hydroxyindoleacetic acid.

    PubMed

    Nuttall, K L; Pingree, S S

    1998-01-01

    A 24-hour urine collection for 5-hydroxyindoleacetic acid (HIAA) is commonly performed to evaluate patients with suspected carcinoid syndrome. However, carcinoids are rare, and elevated results are common even when using an analytically specific method. To characterize this problem, the incidence of elevated results was examined in a population of 947 patient specimens received in a clinical reference laboratory setting. Using a reference limit of 15 mg/d identified 7.9 percent of the results as elevated, with 3 percent > 100 mg/d, and about 1 percent > 350 mg/d. Males showed 14 percent > 15 mg/d compared to 5.2 percent for females. Characterization of incomplete and excess 24-hr urine collections is facilitated by use of a creatinine ratio, with a reference limit of 14 mg/g creatinine equivalent to 15 mg/d. Given the frequency of elevated results, HIAA should be used to support the diagnoses of carcinoid only when consistent with other objective findings.

  15. An aggregate urine analysis tool to detect acute dehydration.

    PubMed

    Hahn, Robert G; Waldréus, Nana

    2013-08-01

    Urine sampling has previously been evaluated for detecting dehydration in young male athletes. The present study investigated whether urine analysis can serve as a measure of dehydration in men and women of a wide age span. Urine sampling and body weight measurement were undertaken before and after recreational physical exercise (median time: 90 min) in 57 volunteers age 17-69 years (mean age: 42). Urine analysis included urine color, osmolality, specific gravity, and creatinine. The volunteers' body weight decreased 1.1% (mean) while they exercised. There were strong correlations between all 4 urinary markers of dehydration (r = .73-.84, p < .001). Researchers constructed a composite dehydration index graded from 1 to 6 based on these markers. This index changed from 2.70 before exercising to 3.55 after exercising, which corresponded to dehydration of 1.0% as given by a preliminary reference curve based on seven previous studies in athletes. Men were slightly dehydrated at baseline (mean: 1.9%) compared with women (mean: 0.7%; p < .001), though age had no influence on the results. A final reference curve that considered both the present results and the 7 previous studies was constructed in which exercise-induced weight loss (x) was predicted by the exponential equation x = 0.20 dehydration index1.86. Urine sampling can be used to estimate weight loss due to dehydration in adults up to age 70. A robust dehydration index based on four indicators reduces the influence of confounders.

  16. Biomonitoring of boron: Development and characterization of a simple, reliable and quality controlled biomonitoring method.

    PubMed

    Michalke, Bernhard

    2017-03-01

    Boron exposure is of interest and concern from an occupational point of view. Usual daily boron intake is related to boron blood plasma concentration <1mg/L and to <3mg/L in urine, but after exposure urine concentrations are quickly elevated. Reliable boron biomonitoring, typically in urine, thus is mandatory for occupational health control institutions. This paper reports on the development of a simple, fast and reliable boron determination procedure based on inductively coupled plasma - optical emission spectrometry (ICP-OES). Major aims for this method were simplicity in sample preparation, low risk for artifacts and interferences, high precision and accuracy, possibly low costs, including lower costs for element selective detection, short total analysis time and suitability for occupational health laboratories. Precision data (serial or day-to-day) from urine and doped urine were very good: <1.5 or <2%. Accuracy was calculated from analysis of a certified reference material (ERM-CD 281), as 99% or according to recoveries of doped concentrations ranging from 102 to 109% recovery. For cross-checking ICP-OES determinations, samples were analyzed also by quadrupole ICP-qMS and by sectorfield ICP-sf-MS at low and medium resolution. Both systems confirmed ICP-OES measurements when using 11 B for quantification. Determinations based on 10 B however showed some bias, except with ICP-sf-MS at medium resolution. The observed elevated signals are discussed with respect to the known Ne ++ interference (as an impurity in Ar), which is not separated in low resolving quadrupole ICP-MS systems or ICP-sf-MS at low resolution. Copyright © 2016 Elsevier GmbH. All rights reserved.

  17. [Determination of normal reference value of pyrrole adducts in urine in young people in a university in Shandong, China].

    PubMed

    Wang, Hui; Wang, Yiping; Zhou, Zhenwei; Wang, Shuo; Yin, Hongyin; Xie, Keqin

    2015-06-01

    To determine the normal reference value of pyrrole adducts in urine in young people in a university in Shandong, China, and to provide a reliable basis for the clinical diagnosis of n-hexane poisoning. A total of 240 college students were randomly selected. After excluding 32 ineligible students, 208 subjects were included in this study, consisting of 104 males and 104 females, with a mean age of 21?3 years (range: 18 to 24 years). Morning urine was collected from each subject. The content of pyrrole adducts was determined by chromatometry. The content of pyrrole adducts in both male and female obeyed a positively skewed distribution. The median level of pyrrole adducts in male subjects was 0.88 nmol/ml, and the reference value was 0.14-3.92 nmol/ml. The median level of pyrrole adducts in female subjects was 0.93 nmol/ ml, and the reference value was 0.09-3.27 nmol/ml. Student's t test identified no statistical difference in pyrrole adduct level between male and female subjects (t=0.15, P>0.05). The median level of pyrrole adducts in normal young people is 0.91 nmol/ml, and the reference value is 0.11-3.95 nmol/ml.

  18. Human neutral brush border endopeptidase EC 3.4.24.11 in urine, its isolation, characterisation and activity in renal diseases.

    PubMed

    Vlaskou, D; Hofmann, W; Guder, W G; Siskos, P A; Dionyssiou-Asteriou, A

    2000-07-01

    Human neutral brush border endopeptidase (NEP) was purified from the urine of patients suffering from acute toxic tubulointerstitial nephropathy. An enzyme preparation with specific activity of 102 Ug(-1) protein was obtained. The urinary activities of neutral endopeptidase and alanine aminopeptidase were measured in patients with renal disease and in 30 control patients, resulting in a reference range from 0.1 to 0.7 Ug(-1) creatinine and 1.4-14.1 Ug(-1) creatinine, respectively. Urine enzyme activities were highest in patients with acute tubulotoxic renal diseases. Neutral endopeptidase and alanine aminopeptidase activities were found to be 6.5- and 10-fold higher than the upper value of the reference range, respectively. Smaller increases in the rate of excretion of these enzymes (2.5- and 3.5-fold), respectively, were observed in patients suffering from acute tubular insufficiency and even lower increases, 2- and 1.5-fold, respectively, were observed in patients with chronic renal diseases. In diabetics and kidney transplant patients the enzyme excretion rates were within the reference range. Assay of both transmembrane metalloproteinases in urine may prove valuable in serving as markers for renal toxicity. Together with beta-NAG these enzymes could be employed as differentiation markers between acute and chronic tubular insufficiency.

  19. Diagnosis and therapeutic monitoring of inborn errors of creatine metabolism and transport using liquid chromatography-tandem mass spectrometry in urine, plasma and CSF.

    PubMed

    Haas, Dorothea; Gan-Schreier, Hongying; Langhans, Claus-Dieter; Anninos, Alexandros; Haege, Gisela; Burgard, Peter; Schulze, Andreas; Hoffmann, Georg F; Okun, Jürgen G

    2014-03-15

    Biochemical detection of inborn errors of creatine metabolism or transport relies on the analysis of three main metabolites in biological fluids: guanidinoacetate (GAA), creatine (CT) and creatinine (CTN). Unspecific clinical presentation of the diseases might be the cause that only few patients have been diagnosed so far. We describe a LC-MS/MS method allowing fast and reliable diagnosis by simultaneous quantification of GAA, CT and CTN in urine, plasma and cerebrospinal fluid (CSF) and established reference values for each material. For quantification deuterated stable isotopes of each analyte were used as internal standards. GAA, CT and CTN were separated by reversed-phase HPLC. The characterization was carried out by scanning the ions of each compound by negative ion tandem mass spectrometry. Butylation is needed to achieve sufficient signal intensity for GAA and CT but it is not useful for analyzing CTN. The assay is linear in a broad range of analyte concentrations usually found in urine, plasma and CSF. Comparison of the "traditional" cation-exchange chromatography and LC-MS/MS showed proportional differences but linear relationships between the two methods. The described method is characterized by high speed and linearity over large concentration ranges comparable to other published LC-MS methods but with higher sensitivity for GAA and CT. In addition, we present the largest reference group ever published for guanidino compounds in all relevant body fluids. Therefore this method is applicable for high-throughput approaches for diagnosis and follow-up of inborn errors of creatine metabolism and transport. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. ECLSS Sustaining Compatibility Testing on Urine Processor Assembly Nonmetallic Materials for Reformulation of Pretreated Urine Solution

    NASA Technical Reports Server (NTRS)

    Wingard, C. D.

    2015-01-01

    On International Space Station (ISS), the Urine Processor Assembly (UPA) converts human urine and flush water into potable water. The urine is acid-pretreated primarily to control microbial growth. In recent years, the sulfuric acid (H2SO4) pretreatment was believed to be largely responsible for producing salt crystals capable of plugging filters in UPA components and significantly reducing the percentage of water recovery from urine. In 2012, ISS management decided to change the acid pretreatment for urine from sulfuric to phosphoric with the goal of eliminating or minimizing formation of salt crystals. In 2013-2014, as part of the qualification of the phosphoric acid (H3PO4) formulation, samples of 12 nonmetallic materials used in UPA components were immersed for up to one year in pretreated urine and brine solutions made with the new H3PO4 formulation. Dynamic mechanical analysis (DMA) was used to measure modulus (stiffness) of the immersed samples compared to virgin control samples. Such compatibility data obtained by DMA for the H3PO4-based solutions were compared to DMA data obtained for the H2SO4-based solutions in 2002-2003.

  1. Headspace and direct immersion solid phase microextraction procedures for selenite determination in urine, saliva and milk by gas chromatography mass spectrometry.

    PubMed

    Kapsimali, D C; Zachariadis, G A

    2009-10-01

    Two solid phase microextraction modes were investigated and compared for their performance on the determination of selenites in various biological liquids like human urine and saliva and various types of milk. Using sodium tetraethylborate (NaBEt(4)) as ethylating reagent, selenites are converted in situ to volatile diethylselenides (DESe) in aqueous medium. The derivative is collected in situ by solid phase microextraction (SPME) using a silica fiber coated with poly(dimethylsiloxane) (PDMS) either from the headspace (HS-SPME) or directly from the liquid phase (LP-SPME) and finally determined by capillary GC/MS. Under optimum conditions of SPME, the GC separation was also optimized. Between the two examined microextraction techniques, direct immersion of the PDMS fiber in the liquid phase was proved less satisfactory. In contrast, the headspace procedure appears to be more efficient. The quantification of selenites was achieved in SIM mode with good analytical performance. A non-fat milk powder certified reference material was analyzed to evaluate the accuracy of the method. The overall precision of the method was ranged between 6.2% and 9.7%. Detection limits achieved were 0.05microgL(-1) for human urine, 0.08microgL(-1) for saliva and 0.03-0.06microgL(-1) in various milk matrices.

  2. Life cycle assessment of segregating fattening pig urine and feces compared to conventional liquid manure management.

    PubMed

    De Vries, Jerke W; Aarnink, André J A; Groot Koerkamp, Peter W G; De Boer, Imke J M

    2013-02-05

    Gaseous emissions from in-house storage of liquid animal manure remain a major contributor to the environmental impact of manure management. Our aim was to assess the life cycle environmental consequences and reduction potential of segregating fattening pig urine and feces with an innovative V-belt system and to compare it to conventional liquid manure management, that is, the reference. Moreover, we aimed at analyzing the uncertainty of the outcomes related to applied emission factors. We compared a reference with two scenarios: segregation with solid, aerobically, stored feces and with liquid, anaerobically, stored feces. Results showed that, compared to the reference, segregation reduced climate change (CC) up to 82%, due to lower methane emission, reduced terrestrial acidification (TA) and particulate matter formation (PMF) up to 49%, through lower ammonia emission, but increased marine eutrophication up to 11% through nitrogen oxide emission from storage and nitrate leaching after field application. Fossil fuel depletion did not change. Segregation with liquid feces revealed lower environmental impact than segregation with solid feces. Uncertainty analysis supported the conclusion that segregating fattening pig urine and feces significantly reduced CC and additionally segregation with liquid feces significantly reduced TA and PMF compared to the reference.

  3. [Usefulness of a real-time quantitative polymerase-chain reaction (PCR) assay for the diagnosis of congenital and postnatal cytomegalovirus infection].

    PubMed

    Reina, J; Weber, I; Riera, E; Busquets, M; Morales, C

    2014-05-01

    Cytomegalovirus (CMV) is the main virus causing congenital and postnatal infections in the pediatric population. The aim of this study is to evaluate the usefulness of a quantitative real-time PCR in the diagnosis of these infections using urine as a single sample. We studied all the urine samples of newborns (< 7 days) with suspected congenital infection, and urine of patients with suspected postnatal infection (urine negative at birth). Urines were simultaneously studied by cell culture, qualitative PCR (PCRc), and quantitative real-time PCR (PCRq). We analyzed 332 urine samples (270 to rule out congenital infection and 62 postnatal infections). Of the first, 22 were positive in the PCRq, 19 in the PCRc, and 17 in the culture. PCRq had a sensitivity of 100%, on comparing the culture with the rest of the techniques. Using the PCRq as a reference method, culture had a sensitivity of 77.2%, and PCRc 86.3%. In cases of postnatal infection, PCRq detected 16 positive urines, the PCRq 12, and the cell culture 10. The urines showed viral loads ranging from 2,178 to 116,641 copies/ml. The genomic amplification technique PCRq in real time was more sensitive than the other techniques evaluated. This technique should be considered as a reference (gold standard), leaving the cell culture as a second diagnostic level. The low cost and the automation of PCRq would enable the screening for CMV infection in large neonatal and postnatal populations. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  4. Urine alkalization facilitates uric acid excretion

    PubMed Central

    2010-01-01

    Background Increase in the incidence of hyperuricemia associated with gout as well as hypertension, renal diseases and cardiovascular diseases has been a public health concern. We examined the possibility of facilitated excretion of uric acid by change in urine pH by managing food materials. Methods Within the framework of the Japanese government's health promotion program, we made recipes which consist of protein-rich and less vegetable-fruit food materials for H+-load (acid diet) and others composed of less protein but vegetable-fruit rich food materials (alkali diet). Healthy female students were enrolled in this consecutive 5-day study for each test. From whole-day collected urine, total volume, pH, organic acid, creatinine, uric acid and all cations (Na+,K+,Ca2+,Mg2+,NH4+) and anions (Cl-,SO42-,PO4-) necessary for the estimation of acid-base balance were measured. Results Urine pH reached a steady state 3 days after switching from ordinary daily diets to specified regimens. The amount of acid generated ([SO42-] +organic acid-gut alkai) were linearly related with those of the excretion of acid (titratable acidity+ [NH4+] - [HCO3-]), indicating that H+ in urine is generated by the metabolic degradation of food materials. Uric acid and excreted urine pH retained a linear relationship, where uric acid excretion increased from 302 mg/day at pH 5.9 to 413 mg/day at pH 6.5, despite the fact that the alkali diet contained a smaller purine load than the acid diet. Conclusion We conclude that alkalization of urine by eating nutritionally well-designed food is effective for removing uric acid from the body. PMID:20955624

  5. The fascinating story of urine examination: From uroscopy to the era of microscopy and beyond.

    PubMed

    Magiorkinis, Emmanouil; Diamantis, Aristidis

    2015-12-01

    The purpose of this study was to present the evolution of ideas on the examination of urine from antiquity till our days. A thorough study of texts, medical books from antiquity till twentieth century along with a thorough review of the available literature in PubMed was conducted. The first observation on urine examination can be traced back to the Babylonian and Sumerian texts. Almost all physicians in antiquity including Hippocrates referred to the value of urine examination in the diagnosis and prognosis of diseases. The construction of first compound microscope lead to the examination of urine sediment and the development of Urine Cytology which was revolutionized during the twentieth century with the studies of important cytologists such as George Papanicolaou, Geoffrey Krabbe, and Leopold Koss. The introduction of molecular tests in the diagnosis of urothelial cancer inaugurated a new era in the study of urine cytology. The history of urine examination spans a period of 6,000 years. The application of microscope in the examination of urine sediment during the nineteenth century established urine analysis as an important diagnostic tool in clinical practice. © 2015 Wiley Periodicals, Inc.

  6. An approach to standardization of urine sediment analysis via suggestion of a common manual protocol.

    PubMed

    Ko, Dae-Hyun; Ji, Misuk; Kim, Sollip; Cho, Eun-Jung; Lee, Woochang; Yun, Yeo-Min; Chun, Sail; Min, Won-Ki

    2016-01-01

    The results of urine sediment analysis have been reported semiquantitatively. However, as recent guidelines recommend quantitative reporting of urine sediment, and with the development of automated urine sediment analyzers, there is an increasing need for quantitative analysis of urine sediment. Here, we developed a protocol for urine sediment analysis and quantified the results. Based on questionnaires, various reports, guidelines, and experimental results, we developed a protocol for urine sediment analysis. The results of this new protocol were compared with those obtained with a standardized chamber and an automated sediment analyzer. Reference intervals were also estimated using new protocol. We developed a protocol with centrifugation at 400 g for 5 min, with the average concentration factor of 30. The correlation between quantitative results of urine sediment analysis, the standardized chamber, and the automated sediment analyzer were generally good. The conversion factor derived from the new protocol showed a better fit with the results of manual count than the default conversion factor in the automated sediment analyzer. We developed a protocol for manual urine sediment analysis to quantitatively report the results. This protocol may provide a mean for standardization of urine sediment analysis.

  7. 49 CFR 40.33 - What training requirements must a collector meet?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...

  8. 49 CFR 40.33 - What training requirements must a collector meet?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...

  9. 49 CFR 40.33 - What training requirements must a collector meet?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...

  10. 49 CFR 40.33 - What training requirements must a collector meet?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...

  11. 49 CFR 40.33 - What training requirements must a collector meet?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...

  12. Urine phyto-oestrogen metabolites are not significantly associated with risk of type 2 diabetes: the Singapore Chinese health study.

    PubMed

    Talaei, Mohammad; Lee, Bee L; Ong, Choon N; van Dam, Rob M; Yuan, Jian M; Koh, Woon P; Pan, An

    2016-05-01

    We evaluated the relationship between urine concentrations of phyto-oestrogens (isoflavones and lignans) and risk of incident type 2 diabetes in middle-aged and elderly Chinese residing in Singapore. Urine metabolites of isoflavones and lignans were assayed by HPLC among 564 diabetes cases and 564 matched controls in a case-control study nested within the Singapore Chinese Health Study cohort. Participants were free of diagnosed diabetes, CVD and cancer at morning urine collections during 1999-2004. Cases were participants who reported to have physician-diagnosed diabetes at follow-up visits during 2006-2010, whereas controls were randomly selected among those who remained free of diabetes and were matched to the index cases by age, sex, dialect group and date of urine collection. Conditional logistic regression models were used to calculate OR and 95 % CI with adjustment for potential confounders. The mean age of the participants at the time of urine collection was 59·8 years, and the average interval between urine collection and diabetes diagnosis was 4·0 years. The multivariate-adjusted OR for diabetes were 1·00 (reference), 0·76 (95 % CI 0·52, 1·11), 0·78 (95 % CI 0·53, 1·14) and 0·79 (95 % CI 0·54, 1·15) across quartiles of urine isoflavones (P for trend=0·54), and were 1·00 (reference), 0·87 (95 % CI 0·60, 1·27), 1·10 (95 % CI 0·77, 1·56) and 0·93 (95 % CI 0·63, 1·37) for lignans (P for trend=0·93). The results were similar in men and women, as well as for individual metabolites of isoflavones (genistein, daidzein, glycitin and equol) or lignans (enterodiol and enterolactone). The present study did not find a significant association between urine phyto-oestrogen metabolites and risk of type 2 diabetes in Chinese adults.

  13. Evaluation of hematological and biochemical parameters of pesticide retailers following occupational exposure to a mixture of pesticides.

    PubMed

    Neghab, Masoud; Jalilian, Hamed; Taheri, Shekoufeh; Tatar, Mohsen; Haji Zadeh, Zeynab

    2018-06-01

    This study was undertaken to ascertain whether light occupational exposure to pesticides by retailers might be associated with any liver, kidney, nervous system dysfunction or hematological abnormalities. In this cross-sectional study, 70 male pesticide retailers (cases) and 64 male subjects, randomly selected from the constructions workers of city council contractors, as the referent group, were investigated. Urine and blood samples were taken from all subjects for urine analysis, hematological and biochemical parameters. Data analysis was conducted through SPSS v.19 using t-test and chi-square test. The results of urine analysis showed that the frequency of abnormal urine tests was significantly higher in cases than in referent individuals. Similarly, the results of CBC showed that the mean values of monocyte, hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin and platelet distribution width were significantly lower, and mean corpuscular hemoglobin concentration and red blood cell distribution width were significantly higher in retailers. No significant differences were found for other parameters. These findings indicate that an association exists between exposure to pesticides by retailers and early subtle and sub-clinical changes in the urine tests and hematological parameters. Engineering measures are recommended to eliminate exposure to pesticides and to prevent its associated outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Analytical and Clinical Validation of the Immulite 1000 hCG Assay for Quantitative Analysis in Urine

    PubMed Central

    Cate, Frances L.; Moffett, Courtney; Gronowski, Ann M.; Grenache, David G.; Hartmann, Katherine E.; Woodworth, Alison

    2013-01-01

    Background The Siemens Immulite hCG assay detects all major hCG variants in serum. Currently, this assay is only FDA approved for qualitative measurement of hCG in urine. Methods Complete validation of the hCG assay in urine was performed on the Siemens Immulite 1000 immunoassay platform. Reference intervals were established for females <55 y, females ≥55 y, and males 20–70 y. Results The limit of quantitation was 2.0 IU/l. The Immulite hCG assay was precise for measuring hCG in urine from pregnant patients with intra- and inter-assay imprecision of <11% CV. The assay was linear over a dynamic range of 2–2600 IU/l and 2–3500 IU/l for hCG and hCGβ respectively. The assay was non-linear for hCGβcf. No hook effect was observed at concentrations up to 1,200,000 pmol/l, for hCGβ or hCGβcf. The reference intervals were <2.0 IU/l for males, <2.2 IU/l for females <55 y, and <12.2 IU/l for females ≥55 y. Conclusion The Immulite 1000 hCG assay can accurately quantify hCG in urine. PMID:23470427

  15. Comparison of Sofia Legionella FIA and BinaxNOW® Legionella urinary antigen card in two national reference centers.

    PubMed

    Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S

    2015-09-01

    The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.

  16. The effect of boric acid on bacterial culture of canine and feline urine.

    PubMed

    Rowlands, M; Blackwood, L; Mas, A; Cripps, P; Crompton, C; Burrow, R

    2011-10-01

    To identify the optimal method of submission of canine and feline urine for bacterial culture. Cystocentesis samples from 250 animals (200 dogs, 50 cats) suspected of having urinary tract infections were collected. The reference aliquot, without preservative, was processed on site within 2 hours. Two further aliquots (one without preservative, one with boric acid) were stored at room temperature for up to 7 hours and then posted by guaranteed next day delivery to a commercial laboratory for analysis. Forty-seven of the samples were positive on culture in the reference test. There was no significant difference between reference test results and those of samples posted without preservative (P=0·39), but samples posted in boric acid were significantly less likely to give a positive result (P=0·01). Samples posted without preservative had a sensitivity of 82% and a specificity of 98%; for boric acid, sensitivity was 73% and specificity 99%. Postal urine samples should be submitted to the laboratory in a plain sterile tube. © 2011 British Small Animal Veterinary Association.

  17. S-phenyl-N-acetylcysteine in urine of rats and workers after exposure to benzene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jongeneelen, F.J.; Dirven, H.A.; Leijdekkers, C.M.

    1987-05-01

    An HPLC method for the determination of S-phenyl-N-acetylcysteine in urine is described. The sensitivity is 6 mumol/L (CV = 9%) urine. Exposure of rats to six different concentrations of benzene, ranging from 0-30 ppm, was highly associated with urinary excretion of S-phenyl-N-acetylcysteine (r = 0.86) and with total phenol (r = 0.81). A background level of phenol was found in urine of both non-exposed rats and of non-exposed referents. However, no background excretion of S-phenyl-N-acetylcysteine was found, either in rats or in humans. In urine of exposed rats, the level of S-phenyl-N-acetylcysteine was approximately five times lower than the phenolmore » level. Workers occupationally exposed to benzene, showing high levels of urinary phenol, revealed low concentrations of urinary S-phenyl-N-acetylcysteine. The biological monitoring of industrial exposure to benzene by determination of S-phenyl-N-acetylcysteine in urine is not better than the determination of phenol in urine.« less

  18. Urinary Concentrations of Bisphenols and Their Association with Biomarkers of Oxidative Stress in People Living Near E-Waste Recycling Facilities in China.

    PubMed

    Zhang, Tao; Xue, Jingchuan; Gao, Chuan-zi; Qiu, Rong-liang; Li, Yan-xi; Li, Xiao; Huang, Ming-zhi; Kannan, Kurunthachalam

    2016-04-05

    In this study, concentrations of bisphenol A (BPA) and seven other bisphenols (BPs) were measured in urine samples collected from people living in and around e-waste dismantling facilities, and in matched reference population from rural and urban areas in China. BPA, bisphenol S (BPS), and bisphenol F (BPF) were frequently detected (detection frequencies: > 90%) in urine samples collected from individuals who live near e-waste facilities, with geometric mean (GM) concentrations of 2.99 (or 3.75), 0.361 (or 0.469), and 0.349 (or 0.435) ng/mL (or μg/g Cre), respectively; the other five BPs were rarely found in urine samples, regardless of the sampling location. The urinary concentrations of BPA and BPF, but not BPS, were significantly higher in individuals from e-waste recycling locations than did individuals from a rural reference location. Our findings indicated that e-waste dismantling activities contribute to human exposure to BPA and BPF. 8-Hydroxy-2'-deoxyguanosine (8-OHdG) was measured in urine as a marker of oxidative stress. In the e-waste dismantling location, urinary 8-OHdG was significantly and positively correlated (p < 0.001) with urinary BPA and BPS, but not BPF; a similar correlation was also observed in reference sites. These findings suggest that BPA and BPS exposures are associated with elevated oxidative stress.

  19. Distribution of copper, iron, and zinc in biological samples (scalp hair, serum, blood, and urine) of Pakistani viral hepatitis (A-E) patients and controls.

    PubMed

    Kolachi, Nida Fatima; Kazi, Tasneem Gul; Afridi, Hassan Imran; Kazi, Naveed; Kandhro, Ghulam Abbas; Shah, Abdul Qadir; Baig, Jameel Ahmed; Wadhwa, Sham Kumar; Khan, Sumaira; Shah, Faheem; Jamali, Mohammad Khan; Arain, Mohammad Balal

    2011-10-01

    The aim of the present study was to compare the level of copper (Cu), iron (Fe) and zinc (Zn) in biological samples (serum, blood, urine, and scalp hair) of patients suffering from different viral hepatitis (A, B, C, D, and E; n = 521) of both gender age ranged 31-45 years. For comparative study, 255 age-matched control subjects, of both genders residing in the same city were selected as referents. The elements in the biological samples were analyzed by flame atomic absorption spectrophotometry, prior to microwave-assisted acid digestion. The validity and accuracy of the methodology was checked by using certified reference materials (CRMs) and with those values obtained by conventional wet acid digestion method on same CRMs. The results of this study showed that the mean values of Cu and Fe were higher in blood, sera, and scalp hair samples of hepatitis patients, while Zn level was found to be lower than age-matched control subjects. The urinary levels of these elements were found to be higher in the hepatitis patients than in the age-matched healthy controls (p < 0.05). These results are consistent with literature-reported data, confirming that the deficiency of zinc and hepatic iron and copper overload can directly cause lipid peroxidation and eventually hepatic damage.

  20. [Concepts of "urinary bladder" and "vesicles (bao)" , "jin ye" (fluid and humor) and "urine" and other associated issues].

    PubMed

    Son, J R; Liu, Y; Ma, Q N; Ju, B Z; Sun, K F; Wu, J D; Zhang, L D; Yang, G L

    2017-09-28

    In the Huang di nei jing ( Huangdi ' s Internal Classic ), jin ye (fluid and humor) is described in two senses, broad and narrow, though not so strictly.Sometimes, jin ye is explained ambiguously as "sweat" and "urine" , as in the phrase "the bladder, being a house of jin ye " , here " jin ye " refers to the urine. In the Qi jue lun pian of Su wen ( Chapter on Qi - Syncope of Plain Questions ) , the " bao " in the sentence "heat of bao moved to bladder" refersto the uterus. In the Shi cong rong lun pian ( Chapter of Readily Inspecting ) of Plain Questions , the "bladder" in the phrase "gallbladder, stomach, large intestine, small intestine, spleen, bao and bladder" , which, being an annotation of " bao " originally, is mistakenly incorporated into the text of the Classic . In the Wu wei lun of Ling shu ( On Five Tastes in Miraculous Pivot ) , the " bao " in " bao of bladder" refers to the external hou (external manifestation) of the bladder, that is the scrotum. In the Bei ji qian jin yao fang ( Essential Prescriptions Worth a Thousand Gold for Emergencies ) , the short sentence " pang guang zou bao " is an error in itself. In the sentence of "settled in the bao and zhi causing to dream of defecation and urination" in the Yin xie fa meng (Dreams due to Evils) of Miraculous Pivot , " bao " refers to uterus, and " zhi " to anus. In Bi lun pian ( Chapter on Impediment ) of Plain Questions , "the man suffered bao bimight feel internal pain when the lesser abdomen and bladder are pressed" , here, " bao " refers to the bladder. In the Wu yin wu wei ( Chapter on Five Sound and Five Tastes ) of Miraculous Pivot , the " bao " in the sentence "thoroughfare vessel and conception vessel all starts from bao " , again, " bao " here refers to the bladder, rather than to the uterus. From the above descriptions of "bladder" and " bao " in the Huangdi ' s Internal Classic , the "bladder" in ancient medical books refers to the substantial bladder, an anatomical organ, and " bao " refers to cystiform organs, including the bladder, uterus, scrotum etc.

  1. Effect of 2 Bedding Materials on Ammonia Levels in Individually Ventilated Cages

    DTIC Science & Technology

    2016-01-01

    primarily from urease -positive bacteria, which metabolize urea from the urine and feces of the animals.8 Therefore, am- monia levels are...proportional to the amounts of wet urine and urease -positive bacteria present in the cage. IVC systems help to reduce the levels of both urine and urease

  2. Values of iodine metabolism biomarkers in assessing the iodine nutrition status in surgically treated patients with thyroid disease.

    PubMed

    Han, Jian-hua; Wu, Lian; Yu, Song-lin; Fang, Hui-ling; Kamg, Wei-ming; Cheng, Xin-qi; Lu, Jie; Yu, Jian-chun; Qiu, Ling

    2015-04-01

    To assess the clinical application value of iodine metabolism biomarkers in assessing iodine nutrition status in surgically treated patients with thyroid disease. Blood,morning urine and 24-hour urine samples were collected in 31 healthy volunteers and in 30 surgically treated patients with thyroid disease before and after surgery. Iodine concentration was analyzed by inductively coupled plasma mass spectrometry. The iodine metabolism biomarkers including serum iodine (SI), morning urine iodine(UI), morning urine iodine/urine creatinine ratio (UI/UCr), 24-hour urine iodine (24 h UI), and 24-hour urine iodine excretion (24 h UIE) were evaluated in these two groups. In addition, the validation coincidence rate of iodine metabolism biomarkers in healthy volunteers to different reference ranges including World Health Organization, Mayo Clinic, and Quest Diagnostics were calculated. The UI/UCr ratio of pre-operative thyroid disease patients was significantly lower than that of healthy volunteers (P<0.05), while the other biomarkers showed no significant differences (all P>0.05) between these two groups. The SI, UI ,and 24 h UI in postoperative thyroid disease patients were significantly higher than those of the pre-operative patients (all P<0.05). Though the medians of all biomarkers in healthy volunteers were within the reference ranges,only the validation coincidence rates of SI, UI, and UI/UCr in the 41-70-year populations were over than 90% according to Mayo Clinic; furthermore, the area under the receiver operating characteristic curve about UI/UCr ratio (0.737) was the biggest within the iodine metabolism biomarkers. The UI/UCr ratio may be used for iodine nutrition evaluation in surgically treated patients with thyroid disease.

  3. A novel way to monitor urine concentration: fluorescent concentration matrices.

    PubMed

    Dubayova, Katarina; Luckova, Iveta; Sabo, Jan; Karabinos, Anton

    2015-01-01

    The amount of water found in urine is important diagnostic information; nevertheless it is not yet directly determined. Indirectly, the water content in urine is expressed by its density (specific gravity). However, without the diuresis value it is not possible to determine whether the increase in density of urine is due to a decrease in water secretion or an increase in the concentration of secreted substances. This problem can be solved by the use of fluorescent concentration 3D-matrices which characterise urine concentration through the pφ (or -logφ) value of the first fluorescence centre. The urine fluorescent concentration 3D-matrix was created by the alignment of the synchronous spectra of the dilution series of urine starting from undiluted (pφ = 0) to 1000-fold diluted urine (pφ = 3). Using the fluorescence concentration 3D-matrix analysis of the urine samples from healthy individuals, a reference range was established for the value pφ, determining the normal, concentrated or diluted type of urine. The diagnostic potential of this approach was tested on urine samples from two patients with a chronic glomerulonephritis. The pφ value of the urine fluorescence concentration 3D-matrix analysis determines whether the urine sample falls within the normal, concentrated or diluted type of urine. This parameter can be directly utilised in sportsmen's hydration state monitoring, as well as in the diagnosis and treatment of serious diseases. An important advantage of this novel diagnostic approach is that a 12/24 h urine collection is not required, which predetermines it for use especially within paediatrics.

  4. Nausea and vomiting

    MedlinePlus

    ... the vomiting is from poisoning Notice blood or dark, coffee-colored material in the vomit Call a ... it usually does Urinating less often or having dark yellow urine What to Expect at Your Office ...

  5. Urine collection device

    NASA Technical Reports Server (NTRS)

    Michaud, R. B. (Inventor)

    1981-01-01

    A urine collection device for females is described. It is comprised of a collection element defining a urine collection chamber and an inlet opening into the chamber and is adapted to be disposed in surrounding relation to the urethral opening of the user. A drainage conduit is connected to the collection element in communication with the chamber whereby the chamber and conduit together comprise a urine flow pathway for carrying urine generally away from the inlet. A first body of wicking material is mounted adjacent the collection element and extends at least partially into the flow pathway. The device preferably also comprise a vaginal insert element including a seal portion for preventing the entry of urine into the vagina.

  6. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio.

    PubMed

    Herrington, William; Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-10-07

    Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long-term frozen storage at -80°C, -40°C, and -20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20-499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at -80°C or -40°C but not at -20°C. Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to -40°C or -80°C for 6 months before analysis also seem suitable. Copyright © 2016 by the American Society of Nephrology.

  7. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio

    PubMed Central

    Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-01-01

    Background and objectives Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Design, setting, participants, & measurements Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long–term frozen storage at −80°C, −40°C, and −20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Results Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20–499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at −80°C or −40°C but not at −20°C. Conclusions Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to −40°C or −80°C for 6 months before analysis also seem suitable. PMID:27654930

  8. Determination of urine ionic composition with potentiometric multisensor system.

    PubMed

    Yaroshenko, Irina; Kirsanov, Dmitry; Kartsova, Lyudmila; Sidorova, Alla; Borisova, Irina; Legin, Andrey

    2015-01-01

    The ionic composition of urine is a good indicator of patient's general condition and allows for diagnostics of certain medical problems such as e.g., urolithiasis. Due to environmental factors and malnutrition the number of registered urinary tract cases continuously increases. Most of the methods currently used for urine analysis are expensive, quite laborious and require skilled personnel. The present work deals with feasibility study of potentiometric multisensor system of 18 ion-selective and cross-sensitive sensors as an analytical tool for determination of urine ionic composition. In total 136 samples from patients of Urolithiasis Laboratory and healthy people were analyzed by the multisensor system as well as by capillary electrophoresis as a reference method. Various chemometric approaches were implemented to relate the data from electrochemical measurements with the reference data. Logistic regression (LR) was applied for classification of samples into healthy and unhealthy producing reasonable misclassification rates. Projection on Latent Structures (PLS) regression was applied for quantitative analysis of ionic composition from potentiometric data. Mean relative errors of simultaneous prediction of sodium, potassium, ammonium, calcium, magnesium, chloride, sulfate, phosphate, urate and creatinine from multisensor system response were in the range 3-13% for independent test sets. This shows a good promise for development of a fast and inexpensive alternative method for urine analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  10. Use of diluted urine for cultivation of Chlorella vulgaris.

    PubMed

    Jaatinen, Sanna; Lakaniemi, Aino-Maija; Rintala, Jukka

    2016-01-01

    Our aim was to study the biomass growth of microalga Chlorella vulgaris using diluted human urine as a sole nutrient source. Batch cultivations (21 days) were conducted in five different urine dilutions (1:25-1:300), in 1:100-diluted urine as such and with added trace elements, and as a reference, in artificial growth medium. The highest biomass density was obtained in 1:100-diluted urine with and without additional trace elements (0.73 and 0.60 g L(-1), respectively). Similar biomass growth trends and densities were obtained with 1:25- and 1:300-diluted urine (0.52 vs. 0.48 gVSS L(-1)) indicating that urine at dilution 1:25 can be used to cultivate microalgal based biomass. Interestingly, even 1:300-diluted urine contained sufficiently nutrients and trace elements to support biomass growth. Biomass production was similar despite pH-variation from < 5 to 9 in different incubations indicating robustness of the biomass growth. Ammonium formation did not inhibit overall biomass growth. At the beginning of cultivation, the majority of the biomass consisted of living algal cells, while towards the end, their share decreased and the estimated share of bacteria and cell debris increased.

  11. Urine therapy through the centuries.

    PubMed

    Savica, Vincenzo; Calò, Lorenzo A; Santoro, Domenico; Monardo, Paolo; Mallamace, Agostino; Bellinghieri, Guido

    2011-01-01

    Urine has always interested and attracted the attention of people. It was in fact never considered a waste product of the body but rather as a distilled product selected from the blood and containing useful substances for the care of the body. It was referred to as the "gold of the blood" and "elixir of long life," indicating its therapeutic potential. This paper reports on the practice of urine therapy since its origin attributed to the Indian culture, and briefly reviews its use through the centuries and different cultures and traditions. Records from the Egyptians to Jews, Greeks, Romans and from the Middle Ages and the Renaissance testify to the practice of urine therapy--a practice that continues to be found in more recent times, from the 18th century to the present. Experiences with the practice of urine therapy have even been discussed and shared recently in 2 different conferences: in 1996 in India and in 1999 in Germany, where people from different countries shared and presented their own research on urine therapy.

  12. Lipid mobilising factors specifically associated with cancer cachexia.

    PubMed Central

    Beck, S. A.; Tisdale, M. J.

    1991-01-01

    Both urine and plasma from mice and humans with cancer cachexia have been shown to contain higher levels of lipid mobilising activity than normal controls, even after acute starvation. There was no significant increase in the urinary lipid mobilising activity of either mice or humans after acute starvation, suggesting that the material in the cachectic situation was probably not due to an elevation of hormones normally associated with the catabolic state in starvation. Further characterisation of the lipid mobilising activity in the urine of cachectic mice using Sephadex G50 exclusion chromatography showed four distinct peaks of activity of apparent molecular weights of greater than 20, 3, 1.5 and less than 0.7 kDa. No comparable peaks of activity were found in the urine of a non tumour-bearing mouse. The high molecular weight activity was probably formed by aggregation of low molecular weight material, since treatment with 0.5 M NaCl caused dissociation to material with a broad spectrum of molecular weights between 3 and 0.7 kDa. Lipolytic species of similar molecular weights were also found in the urine of cachectic cancer patients, but not in normal urine even after 24 h starvation. The lipid mobilising species may be responsible for catabolism of host adipose tissue in the cachectic state. PMID:2069843

  13. Filter paper saturated by urine sample in metabolic disorders detection by proton magnetic resonance spectroscopy.

    PubMed

    Blasco, Hélène; Garrigue, Marie-Ange; De Vos, Aymeric; Antar, Catherine; Labarthe, François; Maillot, François; Andres, Christian R; Nadal-Desbarats, Lydie

    2010-02-01

    NMR spectroscopy of urine samples is able to diagnose many inborn errors of metabolism (IEM). However, urinary metabolites have a poor stability, requiring special care for routine analysis (storage of urine at -20 or -80 degrees C, fast transport). The aim of our study was to investigate the reliability of dried urine filter paper for urine storage and transport and to evaluate the ability of NMR to detect several IEM using this method. Urine samples from five healthy subjects were analyzed by (1)H NMR following different storage conditions (-20 vs 4 degrees C vs dried on filter paper) and at different time points (24 h, 48 h, 96 h, and 7 days). Urine pattern of fresh urine was considered as a reference. We analyzed the conservation of some amino acids and organic acids using Bland and Altman plot with intraclass correlation coefficient determination. Then, we evaluated the use of filter paper to detect four different IEM (methylmalonic and isovaleric acidurias, ornithine transcarbamylase deficiency, and cystinuria). Analysis of urine samples from healthy subjects revealed a high stability of studied molecules (ICC > 0.8) even after 7 days of storage on filter paper. Moreover, an excellent preservation of metabolites specifically accumulated in IEM was observed when analysis of dried urine filter paper was compared to fresh urine (coefficient of variation < 15%). This preliminary study demonstrates that storage of dried urine on filter paper is reliable for (1)H NMR spectroscopy analysis. Preservation of urine molecules over time using that method is convenient for routine clinical practice.

  14. Multiwalled carbon nanotubes as a sorbent material for the solid phase extraction of lead from urine and subsequent determination by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Peña Crecente, Rosa M.; Lovera, Carlha Gutiérrez; García, Julia Barciela; Méndez, Jennifer Álvarez; Martín, Sagrario García; Latorre, Carlos Herrero

    2014-11-01

    The determination of lead in urine is a way of monitoring the chemical exposure to this metal. In the present paper, a new method for the Pb determination by electrothermal atomic absorption spectrometry (ETAAS) in urine at low levels has been developed. Lead was separated from the undesirable urine matrix by means of a solid phase extraction (SPE) procedure. Oxidized multiwalled carbon nanotubes have been used as a sorbent material. Lead from urine was retained at pH 4.0 and was quantitatively eluted using a 0.7 M nitric acid solution and was subsequently measured by ETAAS. The effects of parameters that influence the adsorption-elution process (such as pH, eluent volume and concentration, sampling and elution flow rates) and the atomic spectrometry conditions have been studied by means of different factorial design strategies. Under the optimized conditions, the detection and quantification limits obtained were 0.08 and 0.26 μg Pb L- 1, respectively. The results demonstrate the absence of a urine matrix effect and this is the consequence of the SPE process carried out. Therefore, the developed method is useful for the analysis of Pb at low levels in real samples without the influence of other urine components. The proposed method was applied to the determination of lead in urine samples of unexposed healthy people and satisfactory results were obtained (in the range 3.64-22.9 μg Pb L- 1).

  15. Quantitative estimation of α-PVP metabolites in urine by GC-APCI-QTOFMS with nitrogen chemiluminescence detection based on parent drug calibration.

    PubMed

    Mesihää, Samuel; Rasanen, Ilpo; Ojanperä, Ilkka

    2018-05-01

    Gas chromatography (GC) hyphenated with nitrogen chemiluminescence detection (NCD) and quadrupole time-of-flight mass spectrometry (QTOFMS) was applied for the first time to the quantitative analysis of new psychoactive substances (NPS) in urine, based on the N-equimolar response of NCD. A method was developed and validated to estimate the concentrations of three metabolites of the common stimulant NPS α-pyrrolidinovalerophenone (α-PVP) in spiked urine samples, simulating an analysis having no authentic reference standards for the metabolites and using the parent drug instead for quantitative calibration. The metabolites studied were OH-α-PVP (M1), 2″-oxo-α-PVP (M3), and N,N-bis-dealkyl-PVP (2-amino-1-phenylpentan-1-one; M5). Sample preparation involved liquid-liquid extraction with a mixture of ethyl acetate and butyl chloride at a basic pH and subsequent silylation of the sec-hydroxyl and prim-amino groups of M1 and M5, respectively. Simultaneous compound identification was based on the accurate masses of the protonated molecules for each compound by QTOFMS following atmospheric pressure chemical ionization. The accuracy of quantification of the parent-calibrated NCD method was compared with that of the corresponding parent-calibrated QTOFMS method, as well as with a reference QTOFMS method calibrated with the authentic reference standards. The NCD method produced an equally good accuracy to the reference method for α-PVP, M3 and M5, while a higher negative bias (25%) was obtained for M1, best explainable by recovery and stability issues. The performance of the parent-calibrated QTOFMS method was inferior to the reference method with an especially high negative bias (60%) for M1. The NCD method enabled better quantitative precision than the QTOFMS methods To evaluate the novel approach in casework, twenty post- mortem urine samples previously found positive for α-PVP were analyzed by the parent calibrated NCD method and the reference QTOFMS method. The highest difference in the quantitative results between the two methods was only 33%, and the NCD method's precision as the coefficient of variation was better than 13%. The limit of quantification for the NCD method was approximately 0.25μg/mL in urine, which generally allowed the analysis of α-PVP and the main metabolite M1. However, the sensitivity was not sufficient for the low concentrations of M3 and M5. Consequently, while having potential for instant analysis of NPS and metabolites in moderate concentrations without reference standards, the NCD method should be further developed for improved sensitivity to be more generally applicable. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Urine stability studies for novel biomarkers of acute kidney injury.

    PubMed

    Parikh, Chirag R; Butrymowicz, Isabel; Yu, Angela; Chinchilli, Vernon M; Park, Meyeon; Hsu, Chi-Yuan; Reeves, W Brian; Devarajan, Prasad; Kimmel, Paul L; Siew, Edward D; Liu, Kathleen D

    2014-04-01

    The study of novel urinary biomarkers of acute kidney injury has expanded exponentially. Effective interpretation of data and meaningful comparisons between studies require awareness of factors that can adversely affect measurement. We examined how variations in short-term storage and processing might affect the measurement of urine biomarkers. Cross-sectional prospective. Hospitalized patients from 2 sites: Yale New Haven Hospital (n=50) and University of California, San Francisco Medical Center (n=36). We tested the impact of 3 urine processing conditions on these biomarkers: (1) centrifugation and storage at 4°C for 48 hours before freezing at -80°C, (2) centrifugation and storage at 25°C for 48 hours before freezing at -80°C, and (3) uncentrifuged samples immediately frozen at -80°C. Urine concentrations of 5 biomarkers: neutrophil gelatinase-associated lipocalin (NGAL), interleukin 18 (IL-18), kidney injury molecule 1 (KIM-1), liver-type fatty acid-binding protein (L-FABP), and cystatin C. We measured urine biomarkers by established enzyme-linked immunosorbent assay methods. Biomarker values were log-transformed, and agreement with a reference standard of immediate centrifugation and storage at -80°C was compared using concordance correlation coefficients (CCCs). Neither storing samples at 4°C for 48 hours nor centrifugation had a significant effect on measured levels, with CCCs higher than 0.9 for all biomarkers tested. For samples stored at 25°C for 48 hours, excellent CCC values (>0.9) also were noted between the test sample and the reference standard for NGAL, cystatin C, L-FABP and KIM-1. However, the CCC for IL-18 between samples stored at 25°C for 48 hours and the reference standard was 0.81 (95% CI, 0.66-0.96). No comparisons to fresh, unfrozen samples; no evaluation of the effect of protease inhibitors. All candidate markers tested using the specified assays showed high stability with both short-term storage at 4°C and without centrifugation prior to freezing. For optimal fidelity, urine for IL-18 measurement should not be stored at 25°C before long-term storage or analysis. Copyright © 2014 National Kidney Foundation, Inc. All rights reserved.

  17. [Prohibited substances in cosmetics: prospect of the toxicity of acrylamide].

    PubMed

    Shen, Minxue; Sun, Zhenqiu; Shi, Jingcheng; Hu, Ming; Hu, Jingxuan; Liu, Yanhong

    2012-04-01

    Prohibited substances in cosmetics refer to substances which must not be among the raw material ingredients of cosmetic products. These substances are absorbed mostly through skin, as well as via lung and gastrointestinal tract. Polyacrylamide is ubiquitously used in industry and its decomposition residue acrylamide (ACR) easily finds its way into cosmetic products. ACR can either be oxidized to epoxide glycidamide or conjugated with glutathione, hemoglobin or DNA; ultimately it is excreted in urine. ACR causes neurotoxicity, reproductive toxicity and tumors in rodents. Occupational exposure to ACR causes neurotoxicity in humans; however, epidemiological evidence have not unambiguously answered the question of whether ACR exposure can increase cancer risk for humans.

  18. Trace drug analysis by surface-enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Farquharson, Stuart; Lee, Vincent Y.

    2000-12-01

    Drug overdose involves more than 10 percent of emergency room (ER) cases, and a method to rapidly identify and quantify the abused drug is critical to the ability of the ER physician to administer the appropriate care. To this end, we have been developing a surface-enhanced Raman (SER) active material capable of detecting target drugs at physiological concentrations in urine. The SER-active material consists of a metal-doped sol-gel that provides not only a million fold increase in sensitivity but also reproducible measurements. The porous silica network offers a unique environment for stabilizing SER active metal particles and the high surface area increase the interaction between the analyte and metal particles. The sol-gel has been coated on the inside walls of glass samples vials, such that urine specimens may simply be introduced for analysis. Here we present the surface-enhanced Raman spectra of a series of barbiturates, actual urine specimens, and a drug 'spiked' urine specimen. The utility of pH adjustment to suppress dominant biochemicals associated with urine is also presented.

  19. Usefulness of enzyme immunoassay (EIA) for screening of anti HIV antibodies in urinary specimens: A comparative analysis.

    PubMed

    Sahni, A K; Nagendra, A; Roy, Partha; Patrikar, S

    2014-07-01

    Standard HIV testing is done using serum or plasma. FDA approved ELISA to screen urine for IgG antibodies to HIV-1 in 1996. It is a simple, noninvasive test and is appropriate for developing countries where health care personnel may not be professionally trained or where clean needles for drawing blood may not always be available. 436 individuals with high-risk behavior and strong clinical suspicion of HIV infection were screened for IgG antibodies to HIV-1 in urine by ELISA. Urine HIV testing was performed by enzyme immunoassay, at the ongoing Voluntary Confidential Counseling and Testing Center (VCCTC) at a large tertiary care microbiology lab. The individuals enrolled for the study had high-risk exposure to the virus and majorities were from a state with a high incidence of HIV infection. In all individuals, both serum and urine were tested for IgG antibodies to HIV-1. Overall, 135 individuals (30.96%) were HIV-positive, of whom 96 (71%) had never previously tested positive; 87% of those who tested positive received their results, and most were referred for medical care. Sensitivity, specificity and predictive values of HIV-1 urine ELISA test kit were determined. Sensitivity was found to be 89.6%; 95% CI [82.9-94.0], specificity 97.3%; 95% CI [94.6-98.8], positive predictive value 93.8%; 95% CI [87.8-97.1] and negative predictive value 95.4%; 95% CI [92.3-97.4]. Efficiency, sensitivity, and specificity of the urine-based screening for HIV-1 test kits were excellent as compared to the reference test.

  20. Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice

    PubMed Central

    Schot, Marjolein J C; van Delft, Sanne; Kooijman-Buiting, Antoinette M J; de Wit, Niek J; Hopstaken, Rogier M

    2015-01-01

    Objective Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. Setting All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Primary and secondary outcome measures Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. Results The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. Conclusions The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice. PMID:25986635

  1. Urinary incontinence - injectable implant

    MedlinePlus

    ... injections of material into the urethra to help control urine leakage ( urinary incontinence ) caused by a weak urinary sphincter. ... choose to have implants. Women who have urine leakage and want a ... procedure to control the problem may choose to have an implant ...

  2. Bilateral hydronephrosis

    MedlinePlus

    ... general problems with urination. Alternative Names Hydronephrosis - bilateral Images Female urinary tract Male urinary tract References Elder JS. Obstruction of the urinary tract. In: Kliegman RM, ...

  3. Evaluation of on-line desalter-inductively coupled plasma-mass spectrometry system for determination of Cr(III), Cr(VI), and total chromium concentrations in natural water and urine samples

    NASA Astrophysics Data System (ADS)

    Sun, Y. C.; Lin, C. Y.; Wu, S. F.; Chung, Y. T.

    2006-02-01

    We have developed a simple and convenient method for the determination of Cr(III), Cr(VI), and the total chromium concentrations in natural water and urine samples that use a flow injection on-line desalter-inductively coupled plasma-mass spectrometry system. When using aqueous ammonium chloride (pH 8) as the stripping solution, the severe interference from sodium in the matrix can be eliminated prior to inductively coupled plasma-mass spectrometry measurement, and the Cr(VI) level can be determined directly. To determine the total concentration of Cr in natural water and urine samples, we used H 2O 2 or HNO 3 to decompose the organic matter and convert all chromium species into the Cr(VI) oxidation state. To overcome the spectral interference caused by the matrix chloride ion in the resulting solutions, we employed cool plasma to successfully suppress chloride-based molecular ion interference during the inductively coupled plasma-mass spectrometry measurement. By significantly eliminating interference from the cationic and anionic components in the matrices prior to the inductively coupled plasma-mass spectrometry measurement, we found that the detection limit reached 0.18 μg L - 1 (based on 3 sigma). We validated this method through the analysis of the total chromium content in two reference materials (NIST 1643c and 2670E) and through measuring the recovery in spiked samples.

  4. Repetitive reddish discoloration of urine in a female adolescent following short-distance walking on a smooth road: Questions.

    PubMed

    Siomou, Ekaterini; Baziou, Maria; Premetis, Evagelos; Vercellati, Cristina; Chaliasos, Nikolaos; Makis, Alexandros

    2017-12-01

    A previously healthy 15-year-old girl was evaluated following five episodes of reddish urine discoloration after walking for approximately 30 min on a smooth roadway. In each episode, the discoloration lasted for four to five urinations and followed by normal urine dipstick tests. No other exercise-produced urine discoloration and no other symptoms were reported. Laboratory evaluation during the episodes revealed a reddish urine sample with 3+ hemoglobin/myoglobin and absence of hematuria. Full blood count, serum creatinine, liver function tests, and electrolyte levels were all within normal limits. Myoglobulinuria was excluded, since muscle enzymes were within normal limits. Blood smear analysis showed mild anisopoikilocytosis with stomatocytes and ovalocytes, leading to extended evaluation for erythrocyte disorders. This case is interesting in that the hemoglobinuria occurred after mild walking and was accompanied by erythrocyte morphological changes. This quiz discusses the differential diagnosis of hemoglobinuria with particular reference to the conditions of appearance (after walking) and emphasizes the importance of step-by-step investigations to reach a definitive diagnosis.

  5. The Recovery of Water and Nitrogen from Urine in BLSS

    NASA Astrophysics Data System (ADS)

    Xie, Beizhen; Liu, Hong; Deng, Shengda

    The recycle and reuse of the wastewater is one of the main factors for realizing a higher closure degree of bioregenerative life support system (BLSS), and the treatment and recovery of the crew’s urine are the most difficult and critical issues. Urine contains a lot of water and high concentrations of urea and salts. Water can be used for the irrigation of the plants in BLSS, and the nitrogen is also the necessary nutrient for plant growth. Therefore, if the nitrogen could be recycled simultaneously while desalting the urine, the substance circulation and the closure of BLSS could be improved significantly. In this study, two-step method was conducted to treat the urine and recycle the water and nitrogen. The urea was hydrolyzed firstly, and then the water vapor and ammonia gas were cooled and collected by using reduced pressure distillation in alkaline condition. High temperature acidification and urease processing methods were studied during the urea hydrolysis step. The treatment conditions of both methods were optimized and the degrees of hydrolysis were compared. This investigation may provide a reference for the establishment of the urine recycle in BLSS.

  6. Major Odorants Released as Urinary Volatiles by Urinary Incontinent Patients

    PubMed Central

    Pandey, Sudhir Kumar; Kim, Ki-Hyun; Choi, Si On; Sa, In Young; Oh, Soo Yeon

    2013-01-01

    In this study, volatile urinary components were collected using three different types of samples from patients suffering from urinary incontinence (UI): (1) urine (A); (2) urine + non-used pad (B); and (3) urine + used pad (C). In addition, urine + non-used pad (D) samples from non-patients were also collected as a reference. The collection of urinary volatiles was conducted with the aid of a glass impinger-based mini-chamber method. Each of the four sample types (A through D) was placed in a glass impinger and incubated for 4 hours at 37 °C. Ultra pure air was then passed through the chamber, and volatile urine gas components were collected into Tedlar bags at the other end. These bag samples were then analyzed for a wide range of VOCs and major offensive odorants (e.g., reduced sulfur compounds (RSCs), carbonyls, trimethylamine (TMA), ammonia, etc.). Among the various odorants, sulfur compounds (methanethiol and hydrogen sulfide) and aldehydes (acetaldehyde, butylaldehyde, and isovaleraldehyde) were detected above odor threshold and predicted to contribute most effectively to odor intensity of urine incontinence. PMID:23823973

  7. Testing of Candidate Polymeric Materials for Compatibility with Pure Alternate Pretreat as Part of the Universal Waste Management System (UWMS)

    NASA Technical Reports Server (NTRS)

    Wingard, C. D.

    2018-01-01

    The Universal Waste Management System (UWMS) is an improved Waste Collection System for astronauts living and working in low Earth orbit spacecraft. Polymeric materials used in water recovery on International Space Station are regularly exposed to phosphoric acid-treated 'pretreated' urine. Polymeric materials used in UWMS are not only exposed to pretreated urine, but also to concentrated phosphoric acid with oxidizer before dilution known as 'pure pretreat.' Samples of five different polymeric materials immersed in pure pretreat for 1 year were tested for liquid compatibility by measuring changes in storage modulus with a dynamic mechanical analyzer.

  8. Renal perfusion scintiscan

    MedlinePlus

    ... Radionuclide renal perfusion scan; Perfusion scintiscan - renal; Scintiscan - renal perfusion Images Kidney anatomy Kidney - blood and urine flow Intravenous pyelogram References Rottenberg G, Andi AC. Renal ...

  9. On-Demand Urine Analyzer

    NASA Technical Reports Server (NTRS)

    Farquharson, Stuart; Inscore, Frank; Shende, Chetan

    2010-01-01

    A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

  10. Isomorphic red blood cells using automated urine flow cytometry is a reliable method in diagnosis of bladder cancer.

    PubMed

    Muto, Satoru; Sugiura, Syo-Ichiro; Nakajima, Akiko; Horiuchi, Akira; Inoue, Masahiro; Saito, Keisuke; Isotani, Shuji; Yamaguchi, Raizo; Ide, Hisamitsu; Horie, Shigeo

    2014-10-01

    We aimed to identify patients with a chief complaint of hematuria who could safely avoid unnecessary radiation and instrumentation in the diagnosis of bladder cancer (BC), using automated urine flow cytometry to detect isomorphic red blood cells (RBCs) in urine. We acquired urine samples from 134 patients over the age of 35 years with a chief complaint of hematuria and a positive urine occult blood test or microhematuria. The data were analyzed using the UF-1000i (®) (Sysmex Co., Ltd., Kobe, Japan) automated urine flow cytometer to determine RBC morphology, which was classified as isomorphic or dysmorphic. The patients were divided into two groups (BC versus non-BC) for statistical analysis. Multivariate logistic regression analysis was used to determine the predictive value of flow cytometry versus urine cytology, the bladder tumor antigen test, occult blood in urine test, and microhematuria test. BC was confirmed in 26 of 134 patients (19.4 %). The area under the curve for RBC count using the automated urine flow cytometer was 0.94, representing the highest reference value obtained in this study. Isomorphic RBCs were detected in all patients in the BC group. On multivariate logistic regression analysis, only isomorphic RBC morphology was significantly predictive for BC (p < 0.001). Analytical parameters such as sensitivity, specificity, positive predictive value, and negative predictive value of isomorphic RBCs in urine were 100.0, 91.7, 74.3, and 100.0 %, respectively. Detection of urinary isomorphic RBCs using automated urine flow cytometry is a reliable method in the diagnosis of BC with hematuria.

  11. Urinary mRNA for the Diagnosis of Renal Allograft Rejection: The Issue of Normalization.

    PubMed

    Galichon, P; Amrouche, L; Hertig, A; Brocheriou, I; Rabant, M; Xu-Dubois, Y-C; Ouali, N; Dahan, K; Morin, L; Terzi, F; Rondeau, E; Anglicheau, D

    2016-10-01

    Urinary messenger RNA (mRNA) quantification is a promising method for noninvasive diagnosis of renal allograft rejection (AR), but the quantification of mRNAs in urine remains challenging due to degradation. RNA normalization may be warranted to overcome these issues, but the strategies of gene normalization have been poorly evaluated. Herein, we address this issue in a case-control study of 108 urine samples collected at time of allograft biopsy in kidney recipients with (n = 52) or without (n = 56) AR by comparing the diagnostic value of IP-10 and CD3ε mRNAs-two biomarkers of AR-after normalization by the total amount of RNA, normalization by one of the three widely used reference RNAs-18S, glyceraldehyde-3-phosphate dehydrogenase (GAPDH) and Hypoxanthine-guanine phosphoribosyltransferase (HPRT)-or normalization using uroplakin 1A (UPK) mRNA as a possible urine-specific reference mRNA. Our results show that normalization based on the total quantity of RNA is not substantially improved by additional normalization and may even be worsened with some classical reference genes that are overexpressed during rejection. However, considering that normalization by a reference gene is necessary to ensure polymerase chain reaction (PCR) quality and reproducibility and to suppress the effect of RNA degradation, we suggest that GAPDH and UPK1A are preferable to 18S or HPRT RNA. © Copyright 2016 The American Society of Transplantation and the American Society of Transplant Surgeons.

  12. Renal papillary necrosis

    MedlinePlus

    ... asking your provider. Alternative Names Necrosis - renal papillae; Renal medullary necrosis Images Kidney anatomy Kidney - blood and urine flow References Bushinsky DA, Monk RD. Nephrolithiasis and nephrocalcinosis. ...

  13. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    PubMed Central

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. Conclusions The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease. PMID:26353117

  14. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    PubMed

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.

  15. New Method To Estimate Total Polyphenol Excretion: Comparison of Fast Blue BB versus Folin-Ciocalteu Performance in Urine.

    PubMed

    Hinojosa-Nogueira, Daniel; Muros, Joaquín; Rufián-Henares, José A; Pastoriza, Silvia

    2017-05-24

    Polyphenols are bioactive substances of vegetal origin with a significant impact on human health. The assessment of polyphenol intake and excretion is therefore important. The Folin-Ciocalteu (F-C) method is the reference assay to measure polyphenols in foods as well as their excretion in urine. However, many substances can influence the method, making it necessary to conduct a prior cleanup using solid-phase extraction (SPE) cartridges. In this paper, we demonstrate the use of the Fast Blue BB reagent (FBBB) as a new tool to measure the excretion of polyphenols in urine. Contrary to F-C, FBBB showed no interference in urine, negating the time-consuming and costly SPE cleanup. In addition, it showed excellent linearity (r 2 = 0.9997), with a recovery of 96.4% and a precision of 1.86-2.11%. The FBBB method was validated to measure the excretion of polyphenols in spot urine samples from Spanish children, showing a good correlation between polyphenol intake and excretion.

  16. An ignored cause of red urine in children: rhabdomyolysis due to carnitine palmitoyltransferase II (CPT-II) deficiency.

    PubMed

    Melek, Engin; Bulut, Fatma Derya; Atmış, Bahriye; Yılmaz, Berna Şeker; Bayazıt, Aysun Karabay; Mungan, Neslihan Önenli

    2017-02-01

    Carnitine palmitoyltransferase II (CPT-II) deficiency is an autosomal recessively inherited disorder involving the β-oxidation of long-chain fatty acids, which leads to rhabdomyolysis and subsequent acute renal failure. The clinical phenotype varies from a severe infantile form to a milder muscle form. Here, we report a 9-year-old boy referred to our hospital for the investigation of hematuria with a 2-day history of dark urine and malaise. As no erythrocytes in the microscopic examination of the urine and hemoglobinuria were present, myoglobinuria due to rhabdomyolysis was the most probable cause of dark urine. After excluding the other causes of rhabdomyolysis, with the help of metabolic investigations, the patient was suspected to have CPT-II deficiency, the most common cause of metabolic rhabdomyolysis. Our aim in presenting this case is to emphasize considering rhabdomyolysis in the differential diagnosis of dark urine in order to prevent recurrent rhabdomyolysis and renal injury.

  17. [Passive inhalation of cannabis smoke--is it detectable?].

    PubMed

    Westin, Andreas Austgulen; Slørdal, Lars

    2009-01-15

    It is frequently questioned whether cannabinoids are detectable in urine from individuals having been passively exposed to hashish or marihuana smoke. Literature was reviewed to shed light on an issue that is often debated in the health services, judicial system and in sports. A Medline search with the index terms "cannabis", "hashish", "marihuana" was conducted in September 2007. Summaries, abstracts and reference lists of selected articles were screened for relevancy. Seven experimental studies with humans were identified. Cannabinoids were detected in urine in two studies where the subjects had been exposed to high smoke levels. In studies conducted under less extreme conditions no urine samples were positive for more than a few hours after exposure and the measured cannabinoid levels were low. When cannabinoids are detected in urine with conventional methods and limits of quantification the results are commensurate with active smoking.

  18. Nonkeratinised Squamous Metaplasia of the Urinary Bladder in Children: A Report of Case Experiences

    PubMed Central

    Jurkiewicz, Beata

    2014-01-01

    Background. Squamous metaplasia refers to the pathological transformation of the urothelium leading to nonkeratinised stratified squamous metaplasia (N-KSM). Objective. To present our experiences in the diagnosis and treatment of N-KSM of the urinary bladder in children. Materials and Methods. In this study, we present our experiences in the diagnosis and treatment of N-KSM of the urinary bladder in children aged from 5 to 17 years. From 2005 to 2013, metaplasia was diagnosed in 119 patients. The reasons behind visiting the hospital were nonspecific intense pain in the abdomen, recurrent urinary tract infections, and urination disorders. The most common symptoms of urinary bladder dysfunction were pollakiuria and difficulties in initiating micturition and retention of urine (reduced detrusor muscle activity). Results. In 20/119 patients (16.8%), metaplasia was incidentally diagnosed during cystoscopy performed for other causes. The changes characteristic for squamous metaplasia were diagnosed—in all these patients, a biopsy was performed. In all 119 patients, a squamous metaplasia was histopathologically diagnosed. Conclusions. Squamous metaplasia of the urinary bladder mucosa occurs in children and adolescents. Symptomatic treatment is administered mainly to improve the patients' quality of life and disease prognosis. PMID:24822222

  19. Voided Midstream Urine Culture and Acute Cystitis in Premenopausal Women

    PubMed Central

    Hooton, Thomas M; Roberts, Pacita L.; Cox, Marsha E.; Stapleton, Ann E.

    2014-01-01

    BACKGROUND The cause of acute uncomplicated cystitis is determined on the basis of cultures of voided midstream urine, but few data guide the interpretation of such results, especially when gram-positive bacteria grow. METHODS Women from 18 to 49 years of age with symptoms of cystitis provided specimens of midstream urine, after which we collected urine by means of a urethral catheter for culture (catheter urine). We compared microbial species and colony counts in the paired specimens. The primary outcome was a comparison of positive predictive values and negative predictive values of organisms grown in midstream urine, with the presence or absence of the organism in catheter urine used as the reference. RESULTS The analysis of 236 episodes of cystitis in 226 women yielded 202 paired specimens of midstream urine and catheter urine that could be evaluated. Cultures were positive for uropathogens in 142 catheter specimens (70%), 4 of which had more than one uropathogen, and in 157 midstream specimens (78%). The presence of Escherichia coli in midstream urine was highly predictive of bladder bacteriuria even at very low counts, with a positive predictive value of 102 colony-forming units (CFU) per milliliter of 93% (Spearman’s r = 0.944). In contrast, in midstream urine, enterococci (in 10% of cultures) and group B streptococci (in 12% of cultures) were not predictive of bladder bacteriuria at any colony count (Spearman’s r = 0.322 for enterococci and 0.272 for group B streptococci). Among 41 episodes in which enterococcus, group B streptococci, or both were found in midstream urine, E. coli grew from catheter urine cultures in 61%. CONCLUSIONS Cultures of voided midstream urine in healthy premenopausal women with acute uncomplicated cystitis accurately showed evidence of bladder E. coli but not of enterococci or group B streptococci, which are often isolated with E. coli but appear to rarely cause cystitis by themselves. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases.) PMID:24224622

  20. Novel ion imprinted magnetic mesoporous silica for selective magnetic solid phase extraction of trace Cd followed by graphite furnace atomic absorption spectrometry detection

    NASA Astrophysics Data System (ADS)

    Zhao, Bingshan; He, Man; Chen, Beibei; Hu, Bin

    2015-05-01

    Determination of trace Cd in environmental, biological and food samples is of great significance to toxicological research and environmental pollution monitoring. While the direct determination of Cd in real-world samples is difficult due to its low concentration and the complex matrix. Herein, a novel Cd(II)-ion imprinted magnetic mesoporous silica (Cd(II)-II-MMS) was prepared and was employed as a selective magnetic solid-phase extraction (MSPE) material for extraction of trace Cd in real-world samples followed by graphite furnace atomic absorption spectrometry (GFAAS) detection. Under the optimized conditions, the detection limit of the proposed method was 6.1 ng L- 1 for Cd with the relative standard deviation (RSD) of 4.0% (c = 50 ng L- 1, n = 7), and the enrichment factor was 50-fold. To validate the proposed method, Certified Reference Materials of GSBZ 50009-88 environmental water, ZK018-1 lyophilized human urine and NIES10-b rice flour were analyzed and the determined values were in a good agreement with the certified values. The proposed method exhibited a robust anti-interference ability due to the good selectivity of Cd(II)-II-MMS toward Cd(II). It was successfully employed for the determination of trace Cd(II) in environmental water, human urine and rice samples with recoveries of 89.3-116%, demonstrating that the proposed method has good application potential in real world samples with complex matrix.

  1. Application of ICP-OES to the determination of barium in blood and urine in clinical and forensic analysis.

    PubMed

    Lech, Teresa

    2013-05-01

    Exposure to barium (Ba) mostly occurs in the workplace or from drinking water, but it may sometimes be due to accidental or intentional intoxication. This paper presents a reliable, sensitive method for the determination of Ba in blood and urine: inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave digestion of samples. The overall procedure was checked using Seronorm Whole Blood L-2, Trace Elements Urine and spiked blood and urine samples (0.5-10 µg/mL of Ba). The accuracy of the whole procedure (relative error) was 4% (blood) and 7% (urine); the recovery was 76-104% (blood) and 85-101% (urine). The limits of detection and quantification (Ba λ = 455.403 nm) were 0.11 and 0.4 µg/L of Ba, respectively; precision (relative standard deviation) was below 6% at the level of 15 µg/L of Ba for blood. This method was applied to a case of the poisoning of a man who had been exposed at the workplace for over two years to powdered BaCO3, and who suffered from paralysis and heart disorders. The concentrations of Ba, in μg/L, were 160 (blood), 460 (serum) and 1,458 (urine) upon his admission to the hospital, and 6.1 (blood) and 4.9 (urine) after 11 months (reference values: 3.34 ± 2.20 µg/L of Ba for blood and 4.43 ± 4.60 µg/L of Ba for urine).

  2. Hydrophobic Sand Is a Non-Toxic Method of Urine Collection, Appropriate for Urinary Metal Analysis in the Rat

    PubMed Central

    Hoffman, Jessica F.; Vergara, Vernieda B.; Mog, Steven R.; Kalinich, John F.

    2017-01-01

    Hydrophobic sand is a relatively new method of urine collection in the rodent, comparable to the established method using a metabolic cage. Urine samples are often used in rodent research, especially for biomarkers of health changes after internal contamination from embedded metals, such as in a model of a military shrapnel wound. However, little research has been done on the potential interference of hydrophobic sand with urine metal concentrations either by contamination from the sand particulate, or adsorption of metals from the urine. We compare urine collected from rats using the metabolic cage method and the hydrophobic sand method for differences in metal concentration of common urinary metals, and examine physical properties of the sand material for potential sources of contamination. We found minimal risk of internal contamination of the rat by hydrophobic sand, and no interference of the sand with several common metals of interest (cobalt, strontium, copper, and manganese), although we advise caution in studies of aluminum in urine. PMID:29051457

  3. Identification of hydroxyropivacaine glucuronide in equine urine by ESI+/MS/MS.

    PubMed Central

    Harkins, J D; Karpiesiuk, W; Tobin, T; Dirikolu, L; Lehner, A F

    2000-01-01

    Ropivacaine is a local anesthetic that has a high potential for abuse in racing horses. It can be recovered from urine collected after administration as a hydroxylated metabolite following beta-glucuronidase treatment of the urine. Based on these findings, it has been inferred that ropivacaine is present in equine urine as a glucuronide metabolite; however, these metabolites have never been directly identified. Using ESI+/MS/MS, the presence of a [M+H]+ molecular ion of m/z 467 was demonstrated in urine corresponding to the calculated mass of a hydroxyropivacaine glucuronide +1. The abundance of this ion diminished after glucuronidase treatment with concomitant appearance of a m/z 291 peak, which is consistent with its hydrolysis to hydroxyropivacaine. In further work, the m/z 467 material was fragmented in the MS/MS system, yielding fragments interpretable as hydroxyropivacaine glucuronide. These data are consistent with the presence of a hydroxyropivacaine glucuronide in equine urine and constitute the first direct demonstration of a specific glucuronide metabolite in equine urine. PMID:10935884

  4. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  5. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  6. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  7. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  8. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  9. Urine test could become early detection device.

    PubMed

    1999-03-01

    Researchers at the Clinical Reference Laboratory in Kansas have detected HIV antibodies in the urine of 24 low-risk people who tested negative for HIV in blood tests. These people are presumed to have been exposed to the virus, but it is not known yet if they actually carry the infection. It is possible for the virus and its antibodies to appear in the urogenital tract before spreading to the bloodstream. If this is correct, the urine test could become a way to screen high-risk individuals, who as a result may be able to initiate highly active antiretroviral therapy (HAART) before the infection becomes systemic. Study results will be presented at the American Association of Clinical Chemists meeting.

  10. Effect of human urine on the tensile strength of sutures used for hypospadias surgery.

    PubMed

    Kerstein, Ryan L; Sedaghati, Tina; Seifalian, Alexander M; Kang, Norbert

    2013-06-01

    Hypospadias is the most common congenital condition affecting between 1 in 250 and 300 live births. Even in experienced hands, surgery to repair this congenital defect can have a high complication rate. Wound dehiscence is reported to occur in 5% and fistula formation in 6%-40% depending on technique. The choice of suture material has been shown to affect the complication rate although there is (currently) no consensus about the best suture material to use. Ideally, the sutures used for urethroplasty should be absorbable while maintaining sufficient mechanical strength to support the wounds until they are self-supporting and able to resist urinary flow. Previous studies have compared the effects of human urine on different suture materials especially catgut. However, catgut is now banned in Europe. Our study examined the tensile and breaking strength as well as rate of degradation for four types of absorbable suture now commonly used for hypospadias repairs in the UK. We examined the effect of prolonged storage (up to 27 days) in human urine on 6/0 gauge Vicryl, Vicryl Rapide, Monocryl and polydioxanone (PDS) sutures. These four suture materials are commonly used by the senior plastic consultant surgeon (NK) for hypospadias repairs. 50 mm sections of these suture materials were stored in either urine or saline as control. At specified time points, each suture was placed in a uniaxial load testing machine to assess the stress-strain profile and the mechanical load required to break the suture was measured. Exposure to urine reduced the tensile and breaking strength of all the suture materials tested. PDS demonstrated the greatest resilience. Vicryl Rapide was the weakest suture and degraded completely by day 6. Vicryl and Monocryl had similar degradation profiles, but Vicryl retained more of its tensile strength for longer. There is a balance to be struck between the duration that a suture material must remain in any surgical wound and the risk that it causes foreign body effects. The results of this study suggest that Vicryl has the best characteristics for urethroplasty of the four suture materials tested. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. To observe the intensity of the inflammatory reaction caused by neonatal urine and meconium on the intestinal wall of rats in order to understand etiology of intestinal damage in gastroschisis

    PubMed Central

    Samala, Devdas S.; Parelkar, Sandesh V.; Sanghvi, Beejal V.; Vageriya, Natasha L.; Paradkar, Bhupesh A.; Kandalkar, Bhuvaneshwari M.; Sathe, Pragati A.

    2014-01-01

    Objectives: The aim of this experimental study was to observe the intensity of the inflammatory reaction caused by neonatal urine and meconium on the intestinal wall of rats to better understand etiology of intestinal damage in gastroschisis. Materials and Methods: A total of 24 adult Wistar rats were used as experimental models to simulate the effect of exposed bowel in cases of gastroschisis. The peritoneal cavity of the rats was injected with substances which constitute human amniotic fluid to study the effect on the bowel. Sterile urine and meconium were obtained from newborn humans. The rats were divided into four groups according to the material to be injected. In Group I (Control group) 3 mL of distilled water was injected, in Group II (Urine group) 3 mL of neonatal urine was injected, in Group III (Meconium group) 5% meconium suspension was injected, while in Group IV, a combination of 5% meconium suspension and urine was injected. A total of 3mL solution was injected into the right inferior quadrant twice a day for 5 days. The animals were sacrificed on the 6th day by a high dose of thiopentone sodium. A segment of small bowel specimen was excised, fixed in paraffin, and stained with hematoxylin-eosin for microscopic analysis for determination of the degree of inflammatory reaction in the intestinal wall. All pathology specimens were studied by the same pathologist. Results: The maximum bowel damage was seen in Group II (Urine group) in the form of serositis, severe enteritis, parietal necrosis, and peeling. A lesser degree of damage was observed in Group III (Meconium group) as mild enteritis (mild lymphoid hyperplasia). The least damage was seen in Group IV (Combination of meconium and urine) and Group I (Control group). Conclusion: The intraabdominal injection of neonatal human urine produces significant inflammatory reactions in the intestinal wall of rats. PMID:24604977

  12. Assessment of genotoxic exposure in Swedish coke-oven work by different methods of biological monitoring.

    PubMed

    Reuterwall, C; Aringer, L; Elinder, C G; Rannug, A; Levin, J O; Juringe, L; Onfelt, A

    1991-04-01

    This study evaluated the results of several biological methods used simultaneously to monitor coke-oven work. Blood samples from 44 male coke-oven workers and 48 male referents, matched for age and smoking/snuff consumption, were examined for cytogenetic damage in lymphocytes. Urinary thioether excretion was determined for 62, and urine mutagenicity for 31, of the subjects, who followed a standardized diet during the urine sampling. Exposure to polycyclic aromatic hydrocarbons varied with work task, the ambient air levels of benzo[a]pyrene sometimes exceeding 5 micrograms/m3. Cytogenetic damage, urine mutagenicity, and thioether excretion did not differ between the groups. The smokers, however, had significantly higher sister chromatid exchange frequencies, urine mutagenicity, and thioether excretion than the nonsmokers. The absence of biological indications of genotoxic exposure was unexpected and indicates that the studied methods are not adequate to assess the carcinogenic risks of Swedish coke-oven workers.

  13. Requirements for radiation emergency urine bioassay techniques for the public and first responders.

    PubMed

    Li, Chunsheng; Vlahovich, Slavica; Dai, Xiongxin; Richardson, Richard B; Daka, Joseph N; Kramer, Gary H

    2010-11-01

    Following a radiation emergency, the affected public and the first responders may need to be quickly assessed for internal contamination by the radionuclides involved. Urine bioassay is one of the most commonly used methods for assessing radionuclide intake and radiation dose. This paper attempts to derive the sensitivity requirements (from inhalation exposure) for the urine bioassay techniques for the top 10 high-risk radionuclides that might be used in a terrorist attack. The requirements are based on a proposed reference dose to adults of 0.1 Sv (CED, committed effective dose). In addition, requirements related to sample turnaround time and field deployability of the assay techniques are also discussed. A review of currently available assay techniques summarized in this paper reveals that method development for ²⁴¹Am, ²²⁶Ra, ²³⁸Pu, and ⁹⁰Sr urine bioassay is needed.

  14. Urine Bacterial Community Convergence through Fertilizer Production: Storage, Pasteurization, and Struvite Precipitation.

    PubMed

    Lahr, Rebecca H; Goetsch, Heather E; Haig, Sarah J; Noe-Hays, Abraham; Love, Nancy G; Aga, Diana S; Bott, Charles B; Foxman, Betsy; Jimenez, Jose; Luo, Ting; Nace, Kim; Ramadugu, Kirtana; Wigginton, Krista R

    2016-11-01

    Source-separated human urine was collected from six public events to study the impact of urine processing and storage on bacterial community composition and viability. Illumina 16S rRNA gene sequencing revealed a complex community of bacteria in fresh urine that differed across collection events. Despite the harsh chemical conditions of stored urine (pH > 9 and total ammonia nitrogen > 4000 mg N/L), bacteria consistently grew to 5 ± 2 × 10 8 cells/mL. Storing hydrolyzed urine for any amount of time significantly reduced the number of operational taxonomic units (OTUs) to 130 ± 70, increased Pielou evenness to 0.60 ± 0.06, and produced communities dominated by Clostridiales and Lactobacillales. After 80 days of storage, all six urine samples from different starting materials converged to these characteristics. Urine pasteurization or struvite precipitation did not change the microbial community, even when pasteurized urine was stored for an additional 70 days. Pasteurization decreased metabolic activity by 50 ± 10% and additional storage after pasteurization did not lead to recovery of metabolic activity. Urine-derived fertilizers consistently contained 16S rRNA genes belonging to Tissierella, Erysipelothrix, Atopostipes, Bacteroides, and many Clostridiales OTUs; additional experiments must determine whether pathogenic species are present, responsible for observed metabolic activity, or regrow when applied.

  15. Atomic spectrometry and trends in clinical laboratory medicine

    NASA Astrophysics Data System (ADS)

    Parsons, Patrick J.; Barbosa, Fernando

    2007-09-01

    Increasing numbers of clinical laboratories are transitioning away from flame and electrothermal AAS methods to those based on ICP-MS. Still, for many laboratories, the choice of instrumentation is based upon (a) the element(s) to be determined, (b) the matrix/matrices to be analyzed, and (c) the expected concentration(s) of the analytes in the matrix. Most clinical laboratories specialize in measuring Se, Zn, Cu, and Al in serum, and/or Pb, Cd, Hg, As, and Cr in blood and/or urine, while other trace elements (e.g., Pt, Au etc.) are measured for therapeutic purposes. Quantitative measurement of elemental species is becoming more widely accepted for nutritional and/or toxicological screening purposes, and ICP-MS interfaced with separation techniques, such as liquid chromatography or capillary electrophoresis, offers the advantage of on-line species determination coupled with very low detection limits. Polyatomic interferences for some key elements such as Se, As, and Cr require instrumentation equipped with dynamic reaction cell or collision cell technologies, or might even necessitate the use of sector field ICP-MS, to assure accurate results. Nonetheless, whatever analytical method is selected for the task, careful consideration must be given both to specimen collection procedures and to the control of pre-analytical variables. Finally, all methods benefit from access to reliable certified reference materials (CRMs). While a variety of reference materials (RMs) are available for trace element measurements in clinical matrices, not all can be classified as CRMs. The major metrological organizations (e.g., NIST, IRMM, NIES) provide a limited number of clinical CRMs, however, secondary reference materials are readily available from commercial organizations and organizers of external quality assessment schemes.

  16. Urinary creatinine concentrations in an industrial workforce and comparison with reference values of the general population.

    PubMed

    Bader, Michael; Messerer, Peter; Will, Wolfgang

    2013-08-01

    Urinary creatinine is an important parameter for the adjustment of metabolite concentrations in differently diluted urine specimens, as a reference dimension for biological limit or guidance values and as a selection criterion for spot urine samples in human biomonitoring. While the creatinine output of the general population has been well described in environmental surveys, this study focused specifically on creatinine concentrations in a large industrial workforce in order to compare these data with the general population and to provide a database for the calculation of a reasonable conversion factor between volume-related and creatinine-adjusted data and vice versa. Urinary creatinine was analysed in 6,438 spot urine samples by a photometric assay in the time period between 1989 and 2009. Basic demographic data (age, sex, body weight, body height) and job category (apprentices, skilled craftsmen, skilled chemical workers, foremen, laboratory staff and executives) were considered in a statistical analysis. The median concentration of urinary creatinine in all urine samples was 1.36 g/L with male employees showing significantly higher values (1.37 g/L, n = 6,148 samples) than female employees (1.00 g/L, n = 290) and concentrations ranging from 0.01 up to 9.76 g/L. Age, body mass index and job category were significant influence factors on urinary creatinine. About 92 % of all samples showed creatinine concentrations between 0.3 and 3.0 g/L, a range recommended by the World Health Organization as a criterion for valid spot urine samples. The results of this study correspond well with data from environmental surveys and with recent data from an active workforce in industry with similar sampling strategies. Therefore, a median of 1.4 g creatinine per litre urine seems to be a reasonable value for general calculations and adjustments. The study data also support the validity of the current recommendations by the WHO and several scientific committees and institutions with respect to creatinine limits in spot urine samples for occupational-medical biomonitoring.

  17. Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice.

    PubMed

    Schot, Marjolein J C; van Delft, Sanne; Kooijman-Buiting, Antoinette M J; de Wit, Niek J; Hopstaken, Rogier M

    2015-05-18

    Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Methodological evaluation and comparison of five urinary albumin measurements.

    PubMed

    Liu, Rui; Li, Gang; Cui, Xiao-Fan; Zhang, Dong-Ling; Yang, Qing-Hong; Mu, Xiao-Yan; Pan, Wen-Jie

    2011-01-01

    Microalbuminuria is an indicator of kidney damage and a risk factor for the progression kidney disease, cardiovascular disease, and so on. Therefore, accurate and precise measurement of urinary albumin is critical. However, there are no reference measurement procedures and reference materials for urinary albumin. Nephelometry, turbidimetry, colloidal gold method, radioimmunoassay, and chemiluminescence immunoassay were performed for methodological evaluation, based on imprecision test, recovery rate, linearity, haemoglobin interference rate, and verified reference interval. Then we tested 40 urine samples from diabetic patients by each method, and compared the result between assays. The results indicate that nephelometry is the method with best analytical performance among the five methods, with an average intraassay coefficient of variation (CV) of 2.6%, an average interassay CV of 1.7%, a mean recovery of 99.6%, a linearity of R=1.00 from 2 to 250 mg/l, and an interference rate of <10% at haemoglobin concentrations of <1.82 g/l. The correlation (r) between assays was from 0.701 to 0.982, and the Bland-Altman plots indicated each assay provided significantly different results from each other. Nephelometry is the clinical urinary albumin method with best analytical performance in our study. © 2011 Wiley-Liss, Inc.

  19. Atmospheric pressure solid analysis probe coupled to quadrupole-time of flight mass spectrometry as a tool for screening and semi-quantitative approach of polycyclic aromatic hydrocarbons, nitro-polycyclic aromatic hydrocarbons and oxo-polycyclic aromatic hydrocarbons in complex matrices.

    PubMed

    Carrizo, Daniel; Domeño, Celia; Nerín, Isabel; Alfaro, Pilar; Nerín, Cristina

    2015-01-01

    A new screening and semi-quantitative approach has been developed for direct analysis of polycyclic aromatic hydrocarbons (PAHs) and their nitro and oxo derivatives in environmental and biological matrices using atmospheric pressure solid analysis probe (ASAP) quadrupole-time of flight mass spectrometry (Q-TOF-MS). The instrumental parameters were optimized for the analysis of all these compounds, without previous sample treatment, in soil, motor oil, atmospheric particles (ashes) and biological samples such as urine and saliva of smokers and non-smokers. Ion source parameters in the MS were found to be the key parameters, with little variation within PAHs families. The optimized corona current was 4 µA, sample cone voltage 80 V for PAHs, nitro-PAHs and oxo-PAHs, while the desolvation temperatures varied from 300°C to 500°C. The analytical method performance was checked using a certified reference material. Two deuterated compounds were used as internal standards for semi-quantitative purposes together with the pure individual standard for each compound and the corresponding calibration plot. The compounds nitro PAH 9-nitroanthracene and oxo-PAH 1,4-naphthalenedione, were found in saliva and urine in a range below 1 µg/g while the range of PAHs in these samples was below 2 µg/g. Environmental samples provided higher concentration of all pollutants than urine and saliva. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. ICP-MS multielemental determination of metals potentially released from dental implants and articular prostheses in human biological fluids.

    PubMed

    Sarmiento-González, Alejandro; Marchante-Gayón, Juan Manuel; Tejerina-Lobo, José María; Paz-Jiménez, José; Sanz-Medel, Alfredo

    2005-06-01

    A sector field high-resolution (HR)-ICP-MS and an octapole reaction system (ORS)-ICP-MS have been compared for the simultaneous determination of traces of metals (Ti, V, Cr, Co, Ni, and Mo) released from dental implants and articular prostheses in human biological fluids. Optimum sample treatments were evaluated to minimize matrix effects in urine and whole blood. Urine samples were diluted tenfold with ultrapure water, whereas whole blood samples were digested with high-purity nitric acid and hydrogen peroxide and finally diluted tenfold with ultrapure water. In both matrices, internal standardization (Ga and Y) was employed to avoid potential matrix interferences and ICP-MS signal drift. Spectral interferences arising from the plasma gases or the major components of urine and whole blood were identified by (HR)-ICP-MS at 3,000 resolving power. The capabilities of (HR)-ICP-MS and (ORS)-ICP-MS for the removal of such spectral interferences were evaluated and compared. Results indicate that polyatomic interferences, which hamper the determination of such metallic elements in these biological samples, could be overcome by using a resolving power of 3,000. Using (ORS)-ICP-MS, all those elements could be quantified except Ti and V (due to the polyatomic ions 31P16O and 35Cl16O, respectively). The accuracy of the proposed methodologies by (HR)- and (ORS)-ICP-MS was checked against two reference materials. Good agreement between the given values and the concentrations obtained for all the analytes under scrutiny was found except for Ti and V when analyzed by (ORS)-ICP-MS.

  1. Hydride Generation for Headspace Solid-Phase Extraction with CdTe Quantum Dots Immobilized on Paper for Sensitive Visual Detection of Selenium.

    PubMed

    Huang, Ke; Xu, Kailai; Zhu, Wei; Yang, Lu; Hou, Xiandeng; Zheng, Chengbin

    2016-01-05

    A low-cost, simple, and highly selective analytical method was developed for sensitive visual detection of selenium in human urine both outdoors and at home, by coupling hydride generation with headspace solid-phase extraction using quantum dots (QDs) immobilized on paper. The visible fluorescence from the CdTe QDs immobilized on paper was quenched by H2Se from hydride generation reaction and headspace solid-phase extraction. The potential mechanism was investigated by using X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) as well as Density Functional Theory (DFT). Potential interferences from coexisting ions, particularly Ag(+), Cu(2+), and Zn(2+), were eliminated. The selectivity was significantly increased because the selenium hydride was effectively separated from sample matrices by hydride generation. Moreover, due to the high sampling efficiency of hydride generation and headspace solid phase extraction, the sensitivity and the limit of detection (LOD) were significantly improved compared to conventional methods. A LOD of 0.1 μg L(-1) and a relative standard deviation (RSD, n = 7) of 2.4% at a concentration of 20 μg L(-1) were obtained when using a commercial spectrofluorometer as the detector. Furthermore, a visual assay based on the proposed method was developed for the detection of Se, 5 μg L(-1) of selenium in urine can be discriminated from the blank solution with the naked eye. The proposed method was validated by analysis of certified reference materials and human urine samples with satisfactory results.

  2. Comparison between Urine and Cervical Samples for HPV DNA Detection and Typing in Young Women in Colombia.

    PubMed

    Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina

    2016-09-01

    Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.

  3. A Prospective Blinded Evaluation of Urine-DNA Testing for Detection of Urothelial Bladder Carcinoma in Patients with Gross Hematuria.

    PubMed

    Dahmcke, Christina M; Steven, Kenneth E; Larsen, Louise K; Poulsen, Asger L; Abdul-Al, Ahmad; Dahl, Christina; Guldberg, Per

    2016-12-01

    Retrospective studies have provided proof of principle that bladder cancer can be detected by testing for the presence of tumor DNA in urine. We have conducted a prospective blinded study to determine whether a urine-based DNA test can replace flexible cystoscopy in the initial assessment of gross hematuria. A total of 475 consecutive patients underwent standard urological examination including flexible cystoscopy and computed tomography urography, and provided urine samples immediately before (n=461) and after (n=444) cystoscopy. Urine cells were collected using a filtration device and tested for eight DNA mutation and methylation biomarkers. Clinical evaluation identified 99 (20.8%) patients with urothelial bladder tumors. With this result as a reference and based on the analysis of all urine samples, the DNA test had a sensitivity of 97.0%, a specificity of 76.9%, a positive predictive value of 52.5%, and a negative predictive value of 99.0%. In three patients with a positive urine-DNA test without clinical evidence of cancer, a tumor was detected at repeat cystoscopy within 16 mo. Our results suggest that urine-DNA testing can be used to identify a large subgroup of patients with gross hematuria in whom cystoscopy is not required. We tested the possibility of using a urine-based DNA test to check for bladder cancer in patients with visible blood in the urine. Our results show that the test efficiently detects bladder cancer and therefore may be used to greatly reduce the number of patients who would need to undergo cystoscopy. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  4. The Effects of Instrumentation on Urine Cytology and CK-20 Analysis for the Detection of Bladder Cancer.

    PubMed

    Wegelin, Olivier; Bartels, Diny W M; Tromp, Ellen; Kuypers, Karel C; van Melick, Harm H E

    2015-10-01

    To evaluate the effects of cystoscopy on urine cytology and additional cytokeratin-20 (CK-20) staining in patients presenting with gross hematuria. For 83 patients presenting with gross hematuria, spontaneous and instrumented paired urine samples were analyzed. Three patients were excluded. Spontaneous samples were collected within 1 hour before cystoscopy, and the instrumented samples were tapped through the cystoscope. Subsequently, patients underwent cystoscopic evaluation and imaging of the urinary tract. If tumor suspicious lesions were found on cystoscopy or imaging, subjects underwent transurethral resection or ureterorenoscopy. Two blinded uropathological reviewers (DB, KK) evaluated 160 urine samples. Reference standards were results of cystoscopy, imaging, or histopathology. Thirty-seven patients (46.3%) underwent transurethral resection or ureterorenoscopy procedures. In 30 patients (37.5%) tumor presence was confirmed by histopathology. The specificity of urine analysis was significantly higher for spontaneous samples than instrumented samples for both cytology alone (94% vs 72%, P = .01) and for cytology combined with CK-20 analysis (98% vs 84%, P = .02). The difference in sensitivity between spontaneous and instrumented samples was not significant for both cytology alone (40% vs 53%) and combined with CK-20 analysis (67% vs 67%). The addition of CK-20 analysis to cytology significantly increases test sensitivity in spontaneous urine cytology (67% vs 40%, P = .03). Instrumentation significantly decreases specificity of urine cytology. This may lead to unnecessary diagnostic procedures. Additional CK-20 staining in spontaneous urine cytology significantly increases sensitivity but did not improve the already high specificity. We suggest performing urine cytology and CK-20 analysis on spontaneously voided urine. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Multiplexed Microsphere Suspension-Array Assay for Urine Mitochondrial DNA Typing by C-Stretch Length in Hypervariable Regions.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Kawahara, Takashi

    2018-07-01

    The standard method for personal identification and verification of urine samples in doping control is short tandem repeat (STR) analysis using nuclear DNA (nDNA). The DNA concentration of urine is very low and decreases under most conditions used for sample storage; therefore, the amount of DNA from cryopreserved urine samples may be insufficient for STR analysis. We aimed to establish a multiplexed assay for urine mitochondrial DNA typing containing only trace amounts of DNA, particularly for Japanese populations. A multiplexed suspension-array assay using oligo-tagged microspheres (Luminex MagPlex-TAG) was developed to measure C-stretch length in hypervariable region 1 (HV1) and 2 (HV2), five single nucleotide polymorphisms (SNPs), and one polymorphic indel. Based on these SNPs and the indel, the Japanese population can be classified into five major haplogroups (D4, B, M7a, A, D5). The assay was applied to DNA samples from urine cryopreserved for 1 - 1.5 years (n = 63) and fresh blood (n = 150). The assay with blood DNA enabled Japanese subjects to be categorized into 62 types, exhibiting a discriminatory power of 0.960. The detection limit for cryopreserved urine was 0.005 ng of nDNA. Profiling of blood and urine pairs revealed that 5 of 63 pairs showed different C-stretch patterns in HV1 or HV2. The assay described here yields valuable information in terms of the verification of urine sample sources employing only trace amounts of recovered DNA. However, blood cannot be used as a reference sample.

  6. Comparison of initial stream urine samples and cervical samples for detection of human papillomavirus.

    PubMed

    Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige

    2016-08-01

    Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  7. Urine cytology screening of French workers exposed to occupational urinary tract carcinogens: a prospective cohort study over a 20-year period

    PubMed Central

    Rouanet, Lucile; Mulliez, Aurélien; Naughton, Geraldine; Fontana, Luc; Druet-Cabanac, Michel; Moustafa, Farès; Chamoux, Alain

    2017-01-01

    Objectives To demonstrate that urine cytology screening can provide relevant epidemiological data for earlier detection of urothelial cancer caused by occupational exposure. Design Prospective cohort study. Setting Industries using urothelial carcinogens in France. Urine samples were collected on site, after a work week and were analysed at the University Hospital of Clermont-Ferrand, France. Participants Participants were workers exposed to urothelial carcinogens. Women and current smokers at time of study recruitment were exclusion criteria. Outcomes Urine cells atypia were ranged into three classes: negative/normal, atypical/suspicious/dysplasia or positive/malignant. Results We included 2020 workers over a period of 20 years from 1993 to 2013: 606 worked in rubber manufacturing, 692 from metal processing, 245 in chemical industry and 477 in roadwork and building industry. Workers had a mean exposure of 15.2±10.4 years before their first urine cytology screening. There was a mean of 3.4±4.3 urine cytology screenings per worker between 1993 and 2013. 6478 cytology were normal, 462 suspicious and 13 malignant. Suspicious and malignant cytology occurred in 4.8% of workers exposed for 1–10 years, 6.2% for 11–20 years of exposure, 7.6% for 21–30 years and 8.6% for >30 years (p<0.001). Using exposure for 1–10 years as reference, the adjusted OR of receiving a suspicious or malignant diagnosis increased with duration of exposure: OR=1.50 (95% CI 1.10 to 2.05, p=0.01) for 21–30 years and OR=1.78 (95% CI 1.23 to 2.56, p=0.002) for >30 years of exposure. Using metal processing as reference, the risk of pathological urine cytology results increased for rubber manufacturing (OR=1.32, 95% CI 1.05 to 1.65, p=0.02), with a trend for roadwork and building industry (OR=1.39, 95% CI 0.98 to 1.97, p=0.07) and for chemical industry (OR=1.34, 95% CI 0.94 to 1.93, p=0.11). Conclusions Urine cytology is a useful tool in occupational medicine. We promote new guidelines with an early screening of urothelial cancer by cytology, starting with beginning of exposure. PMID:28939575

  8. Intravenous pyelogram

    MedlinePlus

    ... is Performed An IVP can be used to evaluate: An abdominal injury Bladder and kidney infections Blood ... IVP Images Kidney anatomy Kidney - blood and urine flow Intravenous pyelogram References Bishoff JT, Rastinehad AR. Urinary ...

  9. Renal venogram

    MedlinePlus

    ... be black. Other structures will be shades of gray. Veins are not normally seen in an x- ... Venogram - kidney; Renal vein thrombosis - venogram Images Kidney anatomy Kidney - blood and urine flow Renal veins References ...

  10. Urine test for HPV genotypes as a predictor of precancerous cervical lesions and for cervical cancer screening.

    PubMed

    Maged, Ahmed M; Saad, Hany; Salah, Emad; Meshaal, Hadeer; AbdElbar, Mostafa; Omran, Eman; Eldaly, Ashraf

    2018-06-01

    To assess the sensitivity of a urine test for high-risk HPV DNA genotypes in the detection of high-grade squamous intra-epithelial lesion (HSIL) and its correlation with pathologic precancerous lesions. The present prospective cross-sectional study included women referred to Kasr AlAiny Medical School, Cairo, Egypt, for cervical smear anomalies, a history of cervical smear anomalies, or for suspicious cervix between May 1, 2015, and April 30, 2017. Paired urine tests and cervical smears were performed. HPV DNA was detected in urine using polymerase chain reaction and cervical smears were performed with a cervical spatula and a cytobrush. Agreement between urine test results and pathology was examined. In total, 1375 women were included. Urine test for high-risk HPV DNA demonstrated 97.8% (95% confidence interval [CI] 92.1%-99.7%) sensitivity and 100% (95% CI 99.7%-100.0%) specificity for HSIL. Overall, 87 women had a positive urine test for high-risk HPV; of these, 82 (94.3%, 95% CI 87.1%-98.1%) had pathologic findings of cervical intra-epithelial neoplasia 2 or 3 (CIN2/3). Similarly, 89 women had HSIL cytology; again, 82 had CIN2/3 (92.1%; 95% CI, 84.3%-96.4%). There was good agreement between a positive urine test for high-risk HPV DNA genotypes and pathologic findings of CIN2/3. © 2018 International Federation of Gynecology and Obstetrics.

  11. Urinalysis in children and adolescents.

    PubMed

    Utsch, Boris; Klaus, Günter

    2014-09-12

    Urinalysis is the most commonly performed biochemical test in infancy and early childhood. The urine sample should be correctly obtained, age-specific aspects should be considered, and age-dependent reference values should be used. This review is based on a selective literature search in electronic databases, textbooks, and guidelines from Germany and abroad on the acquisition of urine samples and the performance of urinalysis in infancy and early childhood. The timing and mode of acquisition of the urine sample affect the assessment of hematuria, proteinuria, leukocyturia, nitrituria, and the uropathogenic bacterial colony count in the urine culture. Dipstick tests can be used for targeted screening for these features. The test results should be interpreted together with the findings of urine microscopy, the medical history, and the physical examination. Proteinuria should be quantified and differentiated; both of these things can be done either from collected urine or (especially in infants and young children) from a spontaneously voided urine sample, by determination of the protein/creatinine quotient. Orthostatic proteinuria in an adolescent requires no further evaluation or treatment. Hematuria should be characterized as either glomerular or non-glomerular erythrocyturia. Asymptomatic, isolated microhematuria in childhood is not uncommon and often transient; in the absence of a family history, it usually does not require an extensive work-up. Proteinuria combined with hematuria should arouse the suspicion of glomerulonephritis. Urinalysis in infancy and early childhood is a simple and informative diagnostic test as long as the urine sample has been obtained properly and the results are interpreted appropriately for this age group.

  12. Determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine with mass selective detection.

    PubMed

    Hughes, D L; Ritter, D J; Wilson, R D

    2001-11-01

    Method development and validation studies have been completed on an assay that will allow the determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. The accurate determination of 2,4-D in urine is an important factor in monitoring worker and population exposure. These studies successfully validated a method for the detection of 2,4-D in urine at a limit of quantitation (LOQ) of 5.00 ppb (parts per billion) using gas chromatography with mass selective detection (GC/MSD). The first study involved the determination of 2,4-D in control human urine and urine samples fortified with 2,4-D. Due to chromatographic interference, a second study was conducted using 14C-2,4-D to verify the recoverability of 2,4-D from human urine at low levels using the GC/MSD method. The second study supports the results of the original data. The 2,4-D was extracted from human urine using a procedure involving hydrolysis using potassium hydroxide, followed by a liquid-liquid extraction into methylene chloride. The extracted samples were derivatized with diazomethane. The methylated fraction was analyzed by GC/MSD. Quantitation was made by comparison to methylated reference standards of 2,4-D. Aliquots fortified at 5-, 50-, and 500-ppb levels were analyzed. The overall mean recovery for all fortified samples was 90.3% with a relative standard deviation of 14.31%.

  13. Detection of depleted uranium in urine of veterans from the 1991 Gulf War.

    PubMed

    Gwiazda, R H; Squibb, K; McDiarmid, M; Smith, D

    2004-01-01

    American soldiers involved in "friendly fire" accidents during the 1991 Gulf War were injured with depleted-uranium-containing fragments or possibly exposed to depleted uranium via other routes such as inhalation, ingestion, and/or wound contamination. To evaluate the presence of depleted uranium in these soldiers eight years later, the uranium concentration and depleted uranium content of urine samples were determined by inductively coupled plasma mass spectrometry in (a) depleted uranium exposed soldiers with embedded shrapnel, (b) depleted uranium exposed soldiers with no shrapnel, and (c) a reference group of deployed soldiers not involved in the friendly fire incidents. Uranium isotopic ratios measured in many urine samples injected directly into the inductively coupled plasma mass spectrometer and analyzed at a mass resolution m/delta m of 300 appeared enriched in 235U with respect to natural abundance (0.72%) due to the presence of an interference of a polyatomic molecule of mass 234.81 amu that was resolved at a mass resolution m/delta m of 4,000. The 235U abundance measured on uranium separated from these urines by anion exchange chromatography was clearly natural or depleted. Urine uranium concentrations of soldiers with shrapnel were higher than those of the two other groups, and 16 out of 17 soldiers with shrapnel had detectable depleted uranium in their urine. In depleted uranium exposed soldiers with no shrapnel, depleted uranium was detected in urine samples of 10 out of 28 soldiers. The median uranium concentration of urines with depleted uranium from soldiers without shrapnel was significantly higher than in urines with no depleted uranium, though substantial overlap in urine uranium concentrations existed between the two groups. Accordingly, assessment of depleted uranium exposure using urine must rely on uranium isotopic analyses, since urine uranium concentration is not an unequivocal indicator of depleted uranium presence in soldiers with no embedded shrapnel.

  14. Nephrotoxic contaminants in drinking water and urine, and chronic kidney disease in rural Sri Lanka.

    PubMed

    Rango, Tewodros; Jeuland, Marc; Manthrithilake, Herath; McCornick, Peter

    2015-06-15

    Chronic kidney disease of unknown ("u") cause (CKDu) is a growing public health concern in Sri Lanka. Prior research has hypothesized a link with drinking water quality, but rigorous studies are lacking. This study assesses the relationship between nephrotoxic elements (namely arsenic (As), cadmium (Cd), lead (Pb), and uranium (U)) in drinking water, and urine samples collected from individuals with and/or without CKDu in endemic areas, and from individuals without CKDu in nonendemic areas. All water samples - from a variety of source types (i.e. shallow and deep wells, springs, piped and surface water) - contained extremely low concentrations of nephrotoxic elements, and all were well below drinking water guideline values. Concentrations in individual urine samples were higher than, and uncorrelated with, those measured in drinking water, suggesting potential exposure from other sources. Mean urinary concentrations of these elements for individuals with clinically diagnosed CKDu were consistently lower than individuals without CKDu both in endemic and nonendemic areas. This likely stems from the inability of the kidney to excrete these toxic elements via urine in CKDu patients. Urinary concentrations of individuals were also found to be within the range of reference values measured in urine of healthy unexposed individuals from international biomonitoring studies, though these reference levels may not be safe for the Sri Lankan population. The results suggest that CKDu cannot be clearly linked with the presence of these contaminants in drinking water. There remains a need to investigate potential interactions of low doses of these elements (particularly Cd and As) with other risk factors that appear linked to CKDu, prior to developing public health strategies to address this illness. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Mass spectrometric characterization of tamoxifene metabolites in human urine utilizing different scan parameters on liquid chromatography/tandem mass spectrometry.

    PubMed

    Mazzarino, Monica; de la Torre, Xavier; Di Santo, Roberto; Fiacco, Ilaria; Rosi, Federica; Botrè, Francesco

    2010-03-01

    Different liquid chromatographic/tandem mass spectrometric (LC/MS/MS) scanning techniques were considered for the characterization of tamoxifene metabolites in human urine for anti-doping purpose. Five different LC/MS/MS scanning methods based on precursor ion scan (precursor ion scan of m/z 166, 152 and 129) and neutral loss scan (neutral loss of 72 Da and 58 Da) in positive ion mode were assessed to recognize common ions or common losses of tamoxifene metabolites. The applicability of these methods was checked first by infusion and then by the injection of solution of a mixture of reference standards of four tamoxifene metabolites available in our laboratory. The data obtained by the analyses of the mixture of the reference standards showed that the five methods used exhibited satisfactory results for all tamoxifene metabolites considered at a concentration level of 100 ng/mL, whereas the analysis of blank urine samples spiked with the same tamoxifene metabolites at the same concentration showed that the neutral loss scan of 58 Da lacked sufficient specificity and sensitivity. The limit of detection in urine of the compounds studied was in the concentration range 10-100 ng/mL, depending on the compound structure and on the selected product ion. The suitability of these approaches was checked by the analysis of urine samples collected after the administration of a single dose of 20 mg of tamoxifene. Six metabolites were detected: 4-hydroxytamoxifene, 3,4-dihydroxytamoxifene, 3-hydroxy-4-methoxytamoxifene, N-demethyl-4-hydroxytamoxifene, tamoxifene-N-oxide and N-demethyl-3-hydroxy-4-methoxytamoxifene, which is in conformity to our previous work using a time-of-flight (TOF) mass spectrometer in full scan acquisition mode. Copyright (c) 2010 John Wiley & Sons, Ltd.

  16. Detection of different kidney stone types: an ex vivo comparison of ultrashort echo time MRI to reference standard CT.

    PubMed

    Ibrahim, El-Sayed H; Cernigliaro, Joseph G; Pooley, Robert A; Bridges, Mellena D; Giesbrandt, Jamie G; Williams, James C; Haley, William E

    2016-01-01

    With the development of ultrashort echo time (UTE) sequences, it may now be possible to detect kidney stones by using magnetic resonance imaging (MRI). In this study, kidney stones of varying composition and sizes were imaged using both UTE MRI as well as the reference standard of computed tomography (CT), with different surrounding materials and scan setups. One hundred and fourteen kidney stones were inserted into agarose and urine phantoms and imaged both on a dual-energy CT (DECT) scanner using a standard renal stone imaging protocol and on an MRI scanner using the UTE sequence with both head and body surface coils. A subset of the stones representing all composition types and sizes was then inserted into the collecting system of porcine kidneys and imaged in vitro with both CT and MRI. All of the stones were visible on both CT and MRI imaging. DECT was capable of differentiating between uric acid and nonuric acid stones. In MRI imaging, the choice of coil and large field of view (FOV) did not affect stone detection or image quality. The MRI images showed good visualization of the stones' shapes, and the stones' dimensions measured from MRI were in good agreement with the actual values (R(2)=0.886, 0.895, and 0.81 in the agarose phantom, urine phantom, and pig kidneys, respectively). The measured T2 relaxation times ranged from 4.2 to 7.5ms, but did not show significant differences among different stone composition types. UTE MRI compared favorably with the reference standard CT for imaging stones of different composition types and sizes using body surface coil and large FOV, which suggests potential usefulness of UTE MRI in imaging kidney stones in vivo. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Direct detection of boldenone sulfate and glucuronide conjugates in horse urine by ion trap liquid chromatography-mass spectrometry.

    PubMed

    Pu, Fan; McKinney, Andrew R; Stenhouse, Allen M; Suann, Craig J; McLeod, Malcolm D

    2004-12-25

    A study of the equine phase II metabolism of the anabolic agent boldenone is reported. Boldenone sulfate, boldenone glucuronide and their C17-epimers were synthesised as reference standards in our lab and a method was developed for their detection in a horse urine matrix. Solid phase extraction was used to purify the analytes, which were then detected by ion trap LC/MS. Negative and positive ionisation mode MS(2) were used for the detection of sulfate and glucuronide conjugates, respectively. Boldenone sulfate and 17-epiboldenone glucuronide were detected as the major and minor phase II metabolites, respectively, in horse urine samples collected following the administration of boldenone undecylenate by intramuscular injection.

  18. An indoor air quality-pharmacokinetic simulation of passive inhalation of marijuana smoke and the resultant buildup of 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic acid in urine.

    PubMed

    Giardino, N J

    1997-03-01

    In military courts of law, the good soldier defense is often used by the defendant to explain the presence of 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic acid in urine (hereafter referred to as THCA) above the Department of Defense (DOD) established limit of 15 ng/mL. The defense will contend the defendant unwittingly breathed side-stream marijuana smoke, thus resulting in the presence of THCA in the defendant's urine. The purpose of this work was to link an indoor air quality model (IAQ) with a pharmacokinetic (PK) model to predict a passive marijuana smoker's resultant concentration of the major urinary metabolite THCA.

  19. Use of immunoblotting to detect Aspergillus fumigatus antigen in sera and urines of rats with experimental invasive aspergillosis.

    PubMed Central

    Yu, B; Niki, Y; Armstrong, D

    1990-01-01

    Immunoblotting was used to detect Aspergillus fumigatus antigen in sera and urines of immunosuppressed rats experimentally infected with A. fumigatus. Organisms were administered by both intravenous and intratracheal injections. Intravenously infected rats developed disseminated aspergillosis, but intratracheally infected rats developed pulmonary disease only. Fungal cultures of blood and urine samples from infected rats were negative. In the urines of intravenously infected rats, antigen was detected 24 to 48 h after infection; in the urines of intratracheally infected animals, antigen was detected on days 4 to 5 after infection. Antigen in serum was detected later than antigen in urine was. Following sodium dodecyl sulfate-polyacrylamide gel electrophoresis and immunoblotting of serum and urine samples, the most strongly reacting antigenic materials were found in the 88-, 40-, 27-, and 20-kilodalton regions. These dominant antigens appeared to be the same as those of control antigens prepared from A. fumigatus grown in vitro. Rabbit antiserum to Aspergillus filtrate antigen was found to be more immunoreactive than antiserum to mycelial or conidial antigen. No mycelium-specific antigens were detected. Images PMID:2199519

  20. Isolation of glycine betaine and proline betaine from human urine. Assessment of their role as osmoprotective agents for bacteria and the kidney.

    PubMed Central

    Chambers, S T; Kunin, C M

    1987-01-01

    Human urine is osmoprotective for enteric bacteria, permitting E. coli to grow with high concentrations of NaCl and other salts and even higher concentrations of sucrose and mannitol but not urea. The active material in urine is soluble in methanol and is precipitated by ammonium reineckate at acid pH. Using gel filtration and high-pressure liquid chromatography, we have identified two major osmoprotective compounds in urine. One is glycine betaine; the other is proline betaine as demonstrated by nuclear magnetic resonance, mass spectrum scanning, and chemical synthesis. Proline betaine has not been described previously to our knowledge in vertebrate tissues. It is known to be a cell volume-regulating agent for marine red algae and the euryhaline mollusk Elysia chloritica. We suggest that the presence of glycine and proline betaines in human urine may reflect an osmoprotective role for the kidney and that they protect bacteria in the urine only fortuitously. PMID:3546377

  1. Creating a urine black hole

    NASA Astrophysics Data System (ADS)

    Hurd, Randy; Pan, Zhao; Meritt, Andrew; Belden, Jesse; Truscott, Tadd

    2015-11-01

    Since the mid-nineteenth century, both enlisted and fashion-conscious owners of khaki trousers have been plagued by undesired speckle patterns resulting from splash-back while urinating. In recent years, industrial designers and hygiene-driven entrepreneurs have sought to limit this splashing by creating urinal inserts, with the effectiveness of their inventions varying drastically. From this large assortment of inserts, designs consisting of macroscopic pillar arrays seem to be the most effective splash suppressers. Interestingly this design partially mimics the geometry of the water capturing moss Syntrichia caninervis, which exhibits a notable ability to suppress splash and quickly absorb water from impacting rain droplets. With this natural splash suppressor in mind, we search for the ideal urine black hole by performing experiments of simulated urine streams (water droplet streams) impacting macroscopic pillar arrays with varying parameters including pillar height and spacing, draining and material properties. We propose improved urinal insert designs based on our experimental data in hopes of reducing potential embarrassment inherent in wearing khakis.

  2. Genetics Home Reference: Horner syndrome

    MedlinePlus

    ... childhood cancer of the nerve tissues called a neuroblastoma . Horner syndrome can also be caused by problems ... roles of imaging and urine studies to detect neuroblastoma and other responsible mass lesions. Am J Ophthalmol. ...

  3. Gestation-specific reference intervals for comprehensive spot urinary steroid hormone metabolite analysis in normal singleton pregnancy and 6 weeks postpartum.

    PubMed

    Mistry, Hiten D; Eisele, Nicole; Escher, Geneviève; Dick, Bernhard; Surbek, Daniel; Delles, Christian; Currie, Gemma; Schlembach, Dietmar; Mohaupt, Markus G; Gennari-Moser, Carine

    2015-09-04

    Normal pregnancy depends on pronounced adaptations in steroid hormone concentrations. Although in recent years, the understanding of these hormones in pregnancy has improved, the interpretation is hampered by insufficient reference values. Our aim was to establish gestation-specific reference intervals for spot urinary steroid hormone levels in normal singleton pregnancies and 6 weeks postpartum. Cross-sectional multicentre observational study. Women recruited between 2008 and 2013 at 3 University Hospitals in Switzerland (Bern), Scotland (Glasgow) and Austria (Graz). Spot urine was collected from healthy women undergoing a normal pregnancy (age, 16-45 years; mean, 31 years) attending routine antenatal clinics at gestation weeks 11, 20, and 28 and approximately 6 weeks postpartum. Urine steroid hormone levels were analysed using gas-chromatography mass spectrometry. Creatinine was also measured by routine analysis and used for normalisation. From the results, a reference interval was calculated for each hormone metabolite at each trimester and 6 weeks postpartum. Changes in these concentrations between trimesters and postpartum were also observed for several steroid hormones and followed changes proposed for index steroid hormones. Normal gestation-specific reference values for spot urinary steroid hormones throughout pregnancy and early postpartum are now available to facilitate clinical management and research approaches to steroid hormone metabolism in pregnancy and the early postpartum period.

  4. Elimination kinetics of metals after an accidental exposure to welding fumes.

    PubMed

    Schaller, Karl H; Csanady, György; Filser, Johannes; Jüngert, Barbara; Drexler, Hans

    2007-07-01

    We had the opportunity to study the kinetics of metals in blood and urine samples of a flame-sprayer exposed to high accident-prone workplace exposure. We measured over 1 year, the nickel, aluminium, and chromium concentrations in blood and urine specimens after exposure. On this basis, we evaluated the corresponding half-lives. Blood and urine sampling were carried out five times after accidental exposure over a period of 1 year. The metals were analysed by graphite furnace atomic absorption spectrometry and Zeeman compensation with reliable methods. Either a mono-exponential or a bi-exponential function was fitted to the concentration-time courses of selected metals using weighted least squares non-linear regression analysis. The amount excreted in urine was calculated integrating the urinary decay curve and multiplying with the daily creatinine excretion. The first examination was carried out 15 days after exposure. The mean aluminium concentration in plasma was 8.2 microg/l and in urine, 58.4 microg/g creatinine. The mean nickel concentration in blood was 59.6 microg/l and the excretion in urine 700 microg/g creatinine. The mean chromium level in blood was 1.4 microg/l in urine, 7.4 microg/g creatinine. For the three elements, the metal concentrations in blood and urine exceeded the reference values at least in the initial phase. For nickel, the German biological threshold limit values (EKA) were exceeded. Aluminium showed a mono-exponential decay, whereas the elimination of chromium and nickel was biphasic in biological fluids of the accidentally exposed welder. The half-lives were as follows: for aluminium 140 days (urine) and 160 days (plasma); for chromium 40 and 730 days (urine); for nickel 25 and 610 days (urine) as well as 30 and 240 days (blood). The renal clearance of aluminium and nickel was about 2 l/h estimated for the last monitoring day.

  5. Accuracy of urinary human papillomavirus testing for presence of cervical HPV: systematic review and meta-analysis

    PubMed Central

    Pathak, Neha; Dodds, Julie; Khan, Khalid

    2014-01-01

    Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064

  6. Analytical validation and reference intervals for freezing point depression osmometer measurements of urine osmolality in dogs.

    PubMed

    Guerrero, Samantha; Pastor, Josep; Tvarijonaviciute, Asta; Cerón, José Joaquín; Balestra, Graziano; Caldin, Marco

    2017-11-01

    Urine osmolality (UOsm) is considered the most accurate measure of urine concentration and is used to assess body fluid homeostasis and renal function. We performed analytical validation of freezing point depression measurement of canine UOsm, to establish reference intervals (RIs) and to determine the effect of age, sex, and reproductive status on UOsm in dogs. Clinically healthy dogs ( n = 1,991) were retrospectively selected and stratified in groups by age (young [0-12 mo], adults [13-84 mo], and seniors [>84 mo]), sex (females and males), and reproductive status (intact and neutered). RIs were calculated for each age group. Intra- and inter-assay coefficients of variation were <1% in all cases. Good linearity ( r 2 = 1, p < 0.001) and recovery (89-98%) were observed. The limit of detection and limit of quantification were zero. Urine specific gravity and UOsm had a highly significant positive correlation ( r = 0.96, p < 0.001) but had inconsistent agreement. The 95% RI for canine UOsm was 369-2,416 mOsm/kg in young and adult dogs, and 366-2,178 mOsm/kg in seniors. Senior dogs had a significantly lower UOsm than young and adult dogs ( p < 0.000). Neutered females had a significantly lower UOsm than intact female dogs ( p < 0.002). These results indicate that the method evaluated is adequate for UOsm measurement and that RIs based on age and reproductive status should be used in dogs.

  7. Drinking-water disinfection by-products and semen quality: a cross-sectional study in China.

    PubMed

    Zeng, Qiang; Wang, Yi-Xin; Xie, Shao-Hua; Xu, Liang; Chen, Yong-Zhe; Li, Min; Yue, Jing; Li, Yu-Feng; Liu, Ai-Lin; Lu, Wen-Qing

    2014-07-01

    Exposure to disinfection by-products (DBPs) has been demonstrated to impair male reproductive health in animals, but human evidence is limited and inconsistent. We examined the association between exposure to drinking-water DBPs and semen quality in a Chinese population. We recruited 2,009 men seeking semen analysis from the Reproductive Center of Tongji Hospital in Wuhan, China, between April 2011 and May 2012. Each man provided a semen sample and a urine sample. Semen samples were analyzed for sperm concentration, sperm motility, and sperm count. As a biomarker of exposure to drinking-water DBPs, trichloroacetic acid (TCAA) was measured in the urine samples. The mean (median) urinary TCAA concentration was 9.58 (7.97) μg/L (interquartile range, 6.01-10.96 μg/L). Compared with men with urine TCAA in the lowest quartile, increased adjusted odds ratios (ORs) were estimated for below-reference sperm concentration in men with TCAA in the second and fourth quartiles (OR = 1.79; 95% CI: 1.19, 2.69 and OR = 1.51; 95% CI: 0.98, 2.31, respectively), for below-reference sperm motility in men with TCAA in the second and third quartiles (OR = 1.46; 95% CI: 1.12, 1.90 and OR = 1.30; 95% CI: 1.00, 1.70, respectively), and for below-reference sperm count in men with TCAA in the second quartile (OR 1.62; 95% CI: 1.04, 2.55). Nonmonotonic associations with TCAA quartiles were also estimated for semen parameters modeled as continuous outcomes, although significant negative associations were estimated for all quartiles above the reference level for sperm motility. Our findings suggest that exposure to drinking-water DBPs may contribute to decreased semen quality in humans.

  8. Detection and genotyping of HPV in urine samples from Chilean women attending primary health care centers.

    PubMed

    Vergara, Nicolás; Balanda, Monserrat; Hidalgo, Wilma; Martín, Héctor San; Aceituno, Alexis; Roldán, Francisco; Villalón, Tania; Hott, Melissa; Espinoza, Gloria; Quiero, Andrea; Valenzuela, María T; Ramírez, Eugenio

    2018-04-01

    Cervical cancer is the second most common malignant neoplasm in women worldwide representing approximately 10% of all types of cancers. Triage of women through cervical cytology has been an important strategy for the surveillance and control of new cases of cervical cancer. However, in many regions around the world cervical cytology has a low coverage compared to developed countries. The molecular detection of HPV is the most effective method to increase the screening sensitivity of women at risk of developing cervical cancer. There are very few studies about the efficacy of urine testing for detection of HPV in women followed up in primary health care centers. Consequently, the efficacy of using urine HPV screening in these populations has not been addressed yet. Here, we compared the detection of HPV in simultaneous urine and cervical samples of women followed up in primary health care centers. Urine and cervical samples were analyzed in 543 women attending at primary health care centers. HPV was detected by real time PCR, and HPV typing performed by PCR-RLB. A general HPV concordance of 86.2% (κ = 0.72) was determined between urine and cervical samples. The concordance for HPV-16 and 18 was almost perfect (κ = 0.82) and strong (κ = 0.77), respectively. The sensitivity and specificity for all HPV genotypes in urine using cervical samples as reference were 82.1 and 93.7%, respectively. The results showed that urine is a good alternative as clinical sample for HPV screening in women attending primary health care centers. Therefore, urine should be used as an alternative sample for increasing triage coverage either in refractory women participating in Pap surveillance programs or when cervical samples are not available.

  9. Cutoff values for bacteria and leukocytes for urine sediment analyzer FUS200 in culture-positive urinary-tract infections.

    PubMed

    Kocer, Derya; Sarıguzel, Fatma M; Karakukcu, Cıgdem

    2014-08-01

    The microscopic analysis of urine is essential for the diagnosis of patients with urinary tract infections. Quantitative urine culture is the 'gold standard' method for definitive diagnosis of urinary-tract infections, but it is labor-intensive, time consuming, and does not provide the same-day results. The aim of this study was to evaluate the analytical and diagnostic performance of the FUS200 (Changchun Dirui Industry, China), a new urine sedimentation analyzer in comparison to urine culture as the reference method. We evaluated 1000 urine samples, submitted for culture and urine analysis with a preliminary diagnosis of urinary-tract infection. Cut-off values for the FUS200 were determined by comparing the results with urine cultures. The cut-off values by the receiver operating characteristic (ROC) curve technique, sensitivity, and specificity were calculated for bacteria and white blood cells (WBCs). Among the 1000 urine specimens submitted for culture, 637 cultures (63.7%) were negative, and 363 were (36.3%) positive. The best cut-off values obtained from ROC analysis were 16/μL for bacteriuria (sensitivity: 82.3%, specificity: 58%), and 34/μL for WBCs (sensitivity: 72.3%, specificity: 65.2%). The area under the curve (AUC) for the bacteria and WBCs count were 0.71 (95% CI: 0.67-0.74) and, 0.72 (95% CI: 0.69-0.76) respectively. The most important requirement of a rapid diagnostic screening test is sensitivity, and, in this perspective, an unsatisfactory sensitivity by using bacteria recognition and quantification performed by the FUS200 analyzer has been observed. After further technical improvements in particle recognition and laboratory personnel training, the FUS200 might show better results.

  10. Lateral Flow Urine Lipoarabinomannan Assay (LF-LAM) for Diagnosis of Active Tuberculosis in HIV-Infected Adults: a Prospective Cohort Study

    PubMed Central

    Na Songkhla, Munjit; Tantipong, Hutsaya; Tongsai, Sasima; Angkasekwinai, Nasikarn

    2017-01-01

    Abstract Background Early diagnosis and treatment of active tuberculosis (TB) in HIV-positive patients is challenging. Tests based on the detection of mycobacterial lipoarabinomannan (LAM) antigen in urine have emerged as potential point-of-care tests for TB. However, limited data exists on their performance among HIV-TB co-infected patients from Southeast Asian countries. Methods We prospectively recruited HIV-positive adult patients with CD4 count less than or equal to 200/mm3 and symptoms suspected of active TB from two tertiary hospitals between December 2015 and March 2017. Freshly collected urine was applied to the Determine®-TB LAM Ag test strip (4 bands of graded intensity), using grade 1 cutoff. Diagnostic accuracy of urine LAM strip test were assessed against microbiological reference standard, defined as positive Mycobacterium tuberculosis cultured from one or more clinical specimens (definite TB) or composite reference standard including definite TB and probable TB, defined as those have symptoms consistent with TB and response to anti-TB treatment. Results A total of 280 patients were enrolled. Of whom, 72 (25.7%) and 65 (23.2%) had definite and probable TB. Amongst those with definite TB, LF-LAM test gave a sensitivity of 75.0% (95% CI 63.9–83.6), specificity of 86.0% (95% CI 79.4–90.8) and accuracy of 82.3% (95% CI 76.7–86.8). When compared with the composite reference standard, the test yielded a lower sensitivity (61.3%, 95% CI 53.0–69.1) and accuracy (73.9%, 95% CI 68.5–78.7), with equal specificity. The test showed the highest sensitivity (90.5%, 95% CI 77.9–96.2) and accuracy (85.9%, 95% CI 79.2–90.7) but lower specificity (84.0%, 95% CI 75.6–89.9) in HIV-infected patients with CD4 count less than 50/mm3. The sensitivity of the combined LF-LAM or sputum microscopy was higher than that of either test alone (86.1% vs. 75.0%, 61.1%, respectively). Mycobacterium avium complex (MAC) was cultured in 7 out of 20 with false positive result. Urine LAM strip test can remain positive for up to 4 weeks even after anti-TB treatment. Conclusion Urine LAM assay gave the best performance for diagnosis of active TB in advanced HIV-infected patients and provide an additional benefit of a greater simplicity, speed, with a more easily obtainable sample. Disclosures All authors: No reported disclosures.

  11. Improvement of an enzyme immunosorbent assay for detecting antibodies against Dioctophyma renale.

    PubMed

    Pedrassani, Daniela; do Nascimento, Adjair Antonio; André, Marcos Rogério; Machado, Rosangela Zacarias

    2015-09-15

    An available enzyme-linked immunosorbent assay (ELISA) was studied for the detection of anti-Dioctophyma renale antibodies in the sera of dogs using, detection of parasite eggs in urine sediment as a reference test. ELISA uses a soluble antigenic preparation of esophagus of D. renale and the optimal dilutions of the antigen, serum and conjugate were determined by means of checker board titration, using positive (n=13) and negative (n=27) reference serum. The specificity and sensitivity of the ELISA were 93.8% and 92.3% respectively and the kappa index was good (0.76). These results suggest that ELISA described may prove to be an effective serological test for detecting dogs infected and exposed to this parasite mainly dogs that are not eliminating parasite eggs through their urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. A study examining the bias of albumin and albumin/creatinine ratio measurements in urine.

    PubMed

    Jacobson, Beryl E; Seccombe, David W; Katayev, Alex; Levin, Adeera

    2015-10-01

    The objective of the study was to examine the bias of albumin and albumin/creatinine (ACR) measurements in urine. Pools of normal human urine were augmented with purified human serum albumin to generate a series of 12 samples covering the clinical range of interest for the measurement of ACR. Albumin and creatinine concentrations in these samples were analyzed three times on each of 3 days by 24 accredited laboratories in Canada and the USA. Reference values (RV) for albumin measurements were assigned by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) comparative method and gravimetrically. Ten random urine samples (check samples) were analyzed as singlets and albumin and ACR values reported according to the routine practices of each laboratory. Augmented urine pools were shown to be commutable. Gravimetrically assigned target values were corrected for the presence of endogenous albumin using the LC-MS/MS comparative method. There was excellent agreement between the RVs as assigned by these two methods. All laboratory medians demonstrated a negative bias for the measurement of albumin in urine over the concentration range examined. The magnitude of this bias tended to decrease with increasing albumin concentrations. At baseline, only 10% of the patient ACR values met a performance limit of RV ± 15%. This increased to 84% and 86% following post-analytical correction for albumin and creatinine calibration bias, respectively. International organizations should take a leading role in the standardization of albumin measurements in urine. In the interim, accuracy based urine quality control samples may be used by clinical laboratories for monitoring the accuracy of their urinary albumin measurements.

  13. Fully electronic urine dipstick probe for combinatorial detection of inflammatory biomarkers

    PubMed Central

    Kamakoti, Vikramshankar; Kinnamon, David; Choi, Kang Hyeok; Jagannath, Badrinath; Prasad, Shalini

    2018-01-01

    Aim: An electrochemical urine dipstick probe biosensor has been demonstrated using molybdenum electrodes on nanoporous polyamide substrate for the quantitative detection of two inflammatory protein biomarkers, CRP and IL-6. Materials & methods: The electrode interface was characterized using ζ-potential and Fourier transform infrared spectroscopy. Detection of biomarkers was demonstrated by measuring impedance changes associated with the dose concentrations of the two biomarkers. A proof of feasibility of point-of-care implementation of the biosensor was demonstrated using a portable electronics platform. Results & conclusion: Limit of detection of 1 pg/ml was achieved for CRP and IL-6 in human urine and synthetic urine buffers. The developed portable hardware demonstrated close correlation with benchtop equipment results. PMID:29796304

  14. Temporary Urine and Brine Stowage System (TUBSS) Development

    NASA Technical Reports Server (NTRS)

    Dries, Kevin; Carrigan, Caitlin

    2011-01-01

    International Space Station (ISS) crew liquid human waste is treated with chromic and sulfuric acids to maintain stability prior to processing to recover water. This pre-treated urine (PTU) and its processed by-product, brine, are highly toxic fluids that require special containment for on-orbit stowage. The temporary urine and brine stowage syste m (TUBSS) is an assembly used to store and transfer pre-treated urine (PTU) and brine for processing or disposal at a later date. This paper describes the development of the TUBSS, including design for two-fault tolerance and materials selection to maintain a soft, collapsible container. In addition, this paper will provide results of testing as well as lessons learned from the project, culminating in the successful launch of the hardware.

  15. Solid metabolic waste transport and stowage investigation

    NASA Technical Reports Server (NTRS)

    Burt, R. A.; Koesterer, M. G.; Hunt, S. R., Jr.

    1974-01-01

    The basic Waste Collection System (WCS) design under consideration utilized air flow to separate the stool from the WCS user and to transport the fecal material to a slinger device for subsequent deposition on a storage bowel. The major parameters governing stool separation and transport were found to be the area of the air inlet orifices, the configuration of the air inlet orifice and the transport air flow. Separation force and transport velocity of the stool were studied. The developed inlet orifice configuration was found to be an effective design for providing fecal separation and transport. Simulated urine tests and female user tests in zero gravity established air flow rates between 0.08 and 0.25 cu sm/min (3 and 9 scfm) as satisfactory for entrapment, containment and transport of urine using an urinal. The investigation of air drying of fecal material as a substitute for vacuum drying in a WCS breadboard system showed that using baseline conditions anticipated for the shuttle cabin ambient atmosphere, flow rates of 0.14 cu sm/min (5 cfm) were adequate for drying and maintaining biological stability of the fecal material.

  16. Urinary oxalate to creatinine ratios in healthy Turkish schoolchildren

    PubMed Central

    Dursun, Ismail; Çelik, İlknur; Poyrazoglu, Hakan M.; Tanrıkulu, Esen; Sahin, Habibe; Yılmaz, Kenan; Öztürk, Ahmet; Yel, Sibel; Gündüz, Zübeyde; Düşünsel, Ruhan

    2017-01-01

    Abstract Aim: we aimed to establish reference values for urinary oxalate to creatinine ratios in healthy children aged 6–15 years and to investigate the relationship between their nutritional habits and oxalate excretion. Materials and methods: Random urine specimens from 953 healthy children aged 6–15 years were obtained and analyzed for oxalate and creatinine. Additionally, a 24-h dietary recall form was prepared and given to them. The ingredient composition of the diet was calculated. The children were divided into three groups according to age: Group I (69 years, n = 353), Group II (10–12 years, n = 335), and Group III (13–15 years, n = 265). Results: The 95th percentile of the oxalate to creatinine ratio for subjects aged 6–9, 10–12, and 13–15 years were 0.048, 0.042, and 0.042 mg/mg, respectively. The oxalate to creatinine ratio was significantly higher in Group 1 than in Group 2 and Group 3. Urinary oxalate excretion was positively correlated with increased protein intake and negatively correlated with age. A significant positive correlation was determined between urinary oxalate excretion and the proline, serine, protein, and glycine content of diet. Dietary proline intake showed a positive correlation with the urine oxalate to creatinine ratio and was found to be an independent predictor for urinary oxalate. Conclusions: These data lend support to the idea that every country should have its own normal reference values to determine the underlying metabolic risk factor for kidney stone disease since regional variation in the dietary intake of proteins and other nutrients can affect normal urinary excretion of oxalate. PMID:27846788

  17. [Cortisol/creatinine ratio in urine (UCC) of healthy cats].

    PubMed

    Zimmer, C; Reusch, C E

    2003-07-01

    In 31 healthy cats urine samples were taken to determine the cortisol/creatinine ratio (UCC) during hospitalisation and at home. The UCC of the samples, which had been taken in the clinic, was significantly higher (0-19 x 10(-6), Median 3 x 10(-6)) than the one of the samples taken at home (0-4 x 10(-6), Median 1 x 10(-6)). The parameter was neither influenced by the cat's age, sex or the fact that the cat stayed inside or outside, nor by the degree of visible agitation. Assay validation achieved good results regarding precision and accuracy of the measuring of cortisol and creatinine in the urine. The study shows that stress--caused by the visit to the veterinarian--can provoke a significant increase of UCC. Therefore, the parameter should be determined only from urine samples taken at home. Furthermore, it is important to notice that cortisol metabolites are measured in varying degree with the different assays. Therefore, it is inevitable that each laboratory generates its own reference values.

  18. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle R.; Broyan, James Lee, Jr.

    2011-01-01

    Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

  19. Radioimmunoassay for etorphine in horses with a /sup 125/I analog of etorphine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tai, C.L.; Wang, C.; Weckman, T.J.

    1988-05-01

    To improve the sensitivity and specificity of screening for etorphine in horses, an /sup 125/I-labeled etorphine analog was synthesized and an antibody to etorphine was raised in rabbits. A radioimmunoassay (RIA) for etorphine was developed, using these reagents. Bound and free /sup 125/I-labeled etorphine was separated by a double-antibody method that reduced interference from materials associated with equine urine. The /sup 125/I-labeled etorphine binding was rarely greater than 250 pg of background etorphine equivalents/ml in raw urine and was 100 pg/ml in hydrolyzed urine. The /sup 125/I-RIA was capable of detecting etorphine equivalents in urine above these background values. Etorphinemore » equivalents were detected in equine urine samples for about 7 days after 4 mares were dosed with 0.22 microgram of etorphine/kg of body weight, IV. The stability of etorphine in urine from these mares was evaluated. Urine from these dosed mares was held in constant -20 C storage, and aliquots were repeatedly frozen and thawed. When analyzed for etorphine equivalents using an /sup 125/I-RIA, etorphine and its metabolites in urine samples were stable for less than or equal to 38 days if continuously frozen and also were resistant to repeated freezing and thawing.« less

  20. [Analytical performances of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine].

    PubMed

    De Monte, Anne; Cannavo, Isabelle; Caramella, Anne; Ollier, Laurence; Giordanengo, Valérie

    2016-01-01

    Congenital cytomegalovirus (CMV) infection is the leading cause of sensoneurinal disability due to infectious congenital disease. The diagnosis of congenital CMV infection is based on the search of CMV in the urine within the first two weeks of life. Viral culture of urine is the gold standard. However, the PCR is highly sensitive and faster. It is becoming an alternative choice. The objective of this study is the validation of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine. Repeatability, reproducibility, detection limit and inter-sample contamination were evaluated. Urine samples from patients (n=141) were collected and analyzed simultaneously in culture and PCR in order to assess the correlation of these two methods. The sensitivity and specificity of PCR were also calculated. The Abbott RealTime CMV PCR in urine is an automated and sensitive method (detection limit 200 UI/mL). Fidelity is very good (standard deviation of repeatability: 0.08 to 0.15 LogUI/mL and reproducibility 0.18 LogUI/mL). We can note a good correlation between culture and Abbott RealTime CMV PCR (kappa 96%). When considering rapid culture as reference, real-time PCR was highly sensitive (100%) and specific (98.2%). The real-time PCR by Abbott RealTime CMV with m2000 is optimal for CMV detection in urine.

  1. Urine oxalate biological variation in patients with primary hyperoxaluria.

    PubMed

    Clifford-Mobley, Oliver; Sjögren, Anna; Lindner, Elisabeth; Rumsby, Gill

    2016-08-01

    Hyperoxaluria is a well-recognised risk factor for urolithiasis and patients with primary hyperoxaluria (PH) gradually build up calcium oxalate deposits leading to chronic kidney disease. Efforts to improve treatment for PH have focused on reducing urine oxalate excretion and thus decreasing lithogenesis. To determine the efficacy of treatments designed to alter a biochemical parameter it is necessary to know the biological and analytical variation of that parameter. In this study, we estimated the intra-individual biological variation of urine oxalate excretion in patients with PH, and from this determined what would constitute a significant change in the form of a reference change value (RCV). Each patient collected four 24-h urines on consecutive weeks. The intra-individual biological variation of oxalate excretion calculated from these samples ranged from 0 to 36 % with a mean of 14 %. The corresponding RCVs were 4-84 % with a mean of 32 %. This result implies that, on average, a reduction of almost one-third in urine oxalate excretion is required to prove an effect from treatment. The wide range of biological variation between individuals may reflect other, as yet unknown, determinants of oxaluria in PH, as well as inaccuracies in urine collection. The data suggest that it is more appropriate to use individual RCVs established prior to treatment to determine its efficacy: a relatively small fall in urine oxalate excretion may be outside the biological variation of some patients but not of others.

  2. Biomonitoring of trace elements in urine samples of children from a coal-mining region.

    PubMed

    Santos, Marina Dos; Flores Soares, Maria Cristina; Martins Baisch, Paulo Roberto; Muccillo Baisch, Ana Luíza; Rodrigues da Silva Júnior, Flavio Manoel

    2018-04-01

    Biomonitoring through urine samples is important for evaluating environmental exposure, since urine is the main form of excretion for most chemical elements. Children are considered more vulnerable to adverse environmental conditions, especially children in developing countries. This study aimed to biomonitor trace elements in urine samples in children from a coal-mining region in the extreme south of Brazil. A cross-sectional study was conducted on 96 children between 6 and 11 years of age. Socioeconomic data and urine samples were collected to estimate the concentration of iron, zinc, selenium, lead, and cadmium. The prevalence of metals above the reference values was 52.0% for Se, followed by 15.6% for Zn. The data point toward a vulnerability to adverse environmental conditions in these children. Although the concentrations of the elements did not reveal intoxication cases, biomonitoring should be carried out continuously in order to assess exposure to metals and ensure the health of the population. This article provides data that help determine natural levels of metallic elements in children, specifically in South America, which have not yet been established. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Electrochemical incineration of wastes

    NASA Technical Reports Server (NTRS)

    Kaba, L.; Hitchens, G. D.; Bockris, J. O'M.

    1989-01-01

    A low temperature electrolysis process has been developed for the treatment of solid waste material and urine. Experiments are described in which organic materials are oxidized directly at the surface of an electrode. Also, hypochlorite is generated electrochemically from chloride component of urine. Hypochlorite can act as a strong oxidizing agent in solution. The oxidation takes place at 30-60 C and the gaseous products from the anodic reaction are carbon dioxide, nitrogen, oxygen. Hydrogen is formed at the cathode. Carbon monoxide, and nitrogen oxides and methane were not detected in the off gases. Chlorine was evolved at the anode in relatively low amounts.

  4. Urine cytology screening of French workers exposed to occupational urinary tract carcinogens: a prospective cohort study over a 20-year period.

    PubMed

    Dutheil, Frederic; Rouanet, Lucile; Mulliez, Aurélien; Naughton, Geraldine; Fontana, Luc; Druet-Cabanac, Michel; Moustafa, Farès; Chamoux, Alain

    2017-09-21

    To demonstrate that urine cytology screening can provide relevant epidemiological data for earlier detection of urothelial cancer caused by occupational exposure. Prospective cohort study. Industries using urothelial carcinogens in France. Urine samples were collected on site, after a work week and were analysed at the University Hospital of Clermont-Ferrand, France. Participants were workers exposed to urothelial carcinogens. Women and current smokers at time of study recruitment were exclusion criteria. Urine cells atypia were ranged into three classes: negative/normal, atypical/suspicious/dysplasia or positive/malignant. We included 2020 workers over a period of 20 years from 1993 to 2013: 606 worked in rubber manufacturing, 692 from metal processing, 245 in chemical industry and 477 in roadwork and building industry. Workers had a mean exposure of 15.2±10.4 years before their first urine cytology screening. There was a mean of 3.4±4.3 urine cytology screenings per worker between 1993 and 2013. 6478 cytology were normal, 462 suspicious and 13 malignant. Suspicious and malignant cytology occurred in 4.8% of workers exposed for 1-10 years, 6.2% for 11-20 years of exposure, 7.6% for 21-30 years and 8.6% for >30 years (p<0.001). Using exposure for 1-10 years as reference, the adjusted OR of receiving a suspicious or malignant diagnosis increased with duration of exposure: OR=1.50 (95% CI 1.10 to 2.05, p=0.01) for 21-30 years and OR=1.78 (95% CI 1.23 to 2.56, p=0.002) for >30 years of exposure. Using metal processing as reference, the risk of pathological urine cytology results increased for rubber manufacturing (OR=1.32, 95% CI 1.05 to 1.65, p=0.02), with a trend for roadwork and building industry (OR=1.39, 95% CI 0.98 to 1.97, p=0.07) and for chemical industry (OR=1.34, 95% CI 0.94 to 1.93, p=0.11). Urine cytology is a useful tool in occupational medicine. We promote new guidelines with an early screening of urothelial cancer by cytology, starting with beginning of exposure. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Determination of metallothionein in biological fluids using enzyme-linked immunoassay with commercial antibody.

    PubMed

    Milnerowicz, Halina; Bizoń, Anna

    2010-01-01

    Metallothionein (MT) is a low molecular weight cysteine-rich protein with a number of roles in the pro/antioxidant balance and homeostasis of essential metals, such as zinc and copper, and in the detoxification of heavy metals, such as cadmium and mercury. Until now, detection of metallothionein in biological fluids remained difficult because of a lack of a broadly reactive commercial test. Meaningful comparison of the values of metallothionein concentrations reported by different authors using their specific isolation procedures and different conditions of enzyme-linked immunoassay is difficult due to the absence of a reference material for metallothionein. Therefore in the present study, we describe a quantitative assay for metallothionein in biological fluids such as plasma and urine performed by a direct enzyme-linked immunoassay using a commercially available monoclonal mouse anti-metallothionein clone E9 antibody and commercial standards of metallothionein from rabbit liver and a custom preparation of metallothionein from human liver. The sensitivity of the assay for the standard containing two isoforms MT-I and MT-II from human liver was 140 pg/well. The reactivity of the commercial standards and standards containing two isoforms MT-I and MT-II isolated from human liver in our laboratory with a commercial monoclonal mouse anti-metallothionein clone E9 antibody were similar. This suggests that the described ELISA test can be useful for determination of metallothionein concentration in biological fluids. The concentrations of metallothionein in human plasma, erythrocyte lysate and in urine of smoking and non-smoking healthy volunteers are reported. Tobacco smoking increases the extracellular metallothionein concentration (plasma and urine) but does not affect the intracellular concentration (erythrocyte lysate).

  6. Effect of hydro-alcoholic extract of Vernonia cinerea Less. against ethylene glycol-induced urolithiasis in rats

    PubMed Central

    Hiremath, Ravindra D.; Jalalpure, Sunil S.

    2016-01-01

    Objective: Aim of this study is to evaluate antiurolithiatic potential of whole plant hydro-alcoholic (30:70) extract of Vernonia cinerea Less. in accordance to its claims made in ancient literature and also being one of the ingredients of cystone, a marketed formulation widely used in the management of urolithiasis. Materials and Methods: To induce urolithiasis, 0.75% v/v ethylene glycol was administered orally for 14 days. The curative dose of 400 mg/kg b.w. and preventive doses of 100, 200, and 400 mg/kg b.w. were administered from 15th to 28th and 1st to 28 days, respectively. Cystone 750 mg/kg b.w. was selected as the reference standard for both curative and preventive doses. On 28th day, urinate of 24 h was collected and subjected for estimation of calcium, oxalate, and phosphates. Serum biochemical and kidney homogenate analysis was done for determination of renal oxalate contents. Results: The diseased Group II showed marked increase (P < 0.001 vs. normal Group I) in levels of urine calcium, oxalate, and phosphate. Serum creatinine, urea, and uric acid levels were also increased. Histopathological studies of kidney sections revealed significant changes. Treatment with hydro-alcoholic extract of V. cinerea showed significant (P < 0.01 vs. calculi-induced Group II) dose-dependent activity. A progressive increase in urine output, body weight, and decline in concentrations of stone-forming components such as calcium, oxalates, and phosphates was observed. Conclusion: It can be inferred that V. cinerea Less. is effective in ethylene glycol-induced urolithiasis and may have a potential in preventing and curing urolithiasis. PMID:27756957

  7. The Diagnostic Accuracy of Urine-Based Xpert MTB/RIF in HIV-Infected Hospitalized Patients Who Are Smear-Negative or Sputum Scarce

    PubMed Central

    Peter, Jonathan G.; Theron, Grant; Muchinga, Tapuwa E.; Govender, Ureshnie; Dheda, Keertan

    2012-01-01

    Background Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients. Methodology/Principal Findings 281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity). Conclusions/Significance This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity. PMID:22815718

  8. Water Treatment Systems for Long Spaceflights

    NASA Technical Reports Server (NTRS)

    FLynn, Michael T.

    2012-01-01

    Space exploration will require new life support systems to support the crew on journeys lasting from a few days to several weeks, or longer. These systems should also be designed to reduce the mass required to keep humans alive in space. Water accounts for about 80 percent of the daily mass intake required to keep a person alive. As a result, recycling water offers a high return on investment for space life support. Water recycling can also increase mission safety by providing an emergency supply of drinking water, where another supply is exhausted or contaminated. These technologies also increase safety by providing a lightweight backup to stored supplies, and they allow astronauts to meet daily drinking water requirements by recycling the water contained in their own urine. They also convert urine into concentrated brine that is biologically stable and nonthreatening, and can be safely stored onboard. This approach eliminates the need to have a dedicated vent to dump urine overboard. These needs are met by a system that provides a contaminant treatment pouch, referred to as a urine cell or contaminant cell, that converts urine or another liquid containing contaminants into a fortified drink, engineered to meet human hydration, electrolyte, and caloric requirements, using a variant of forward osmosis (FO) to draw water from a urine container into the concentrated fortified drink as part of a recycling stage. An activated carbon pretreatment removes most organic molecules. Salinity of the initial liquid mix (urine plus other) is synergistically used to enhance the precipitation of organic molecules so that activated carbon can remove most of the organics. A functional osmotic bag is then used to remove inorganic contaminants. If a contaminant is processed for which the saline content is different than optimal for precipitating organic molecules, the saline content of the liquid should be adjusted toward the optimal value for that contaminant. A first urine treatment method converts urine into a fortified sports drink, resembling Gatorade, using a first urine cell.

  9. Asymptomatic bacteriuria in pregnant women attending Boo-Ali Hospital Tehran Iran: Urine analysis vs. urine culture.

    PubMed

    Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana

    2017-11-01

    Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Of 123 urine samples, significant asymptomatic bacteriuria (≥10 4 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and specificity of 100%, whereas we can only refer the pregnant women with positive leucocyte esterase test and significant pyuria to the urine culture.

  10. Usefulness of fetal urine production measurement for prediction of perinatal outcomes in uteroplacental insufficiency.

    PubMed

    Lee, Seung Mi; Jun, Jong Kwan; Kim, Su Ah; Lee, Eun Ja; Kim, Byoung Jae; Park, Chan-Wook; Park, Joong Shin

    2014-12-01

    To evaluate whether fetal urine production measurement is useful for predicting adverse outcomes in patients with uteroplacental insufficiency. We enrolled patients with uteroplacental insufficiency at 24 to 40 weeks' gestation and normal pregnancies matched for gestational age and divided them into 3 groups according to perinatal outcomes: group 1 (n = 141), a control group of normal pregnancies; group 2 (n = 29), uteroplacental insufficiency without adverse outcomes; and group 3 (n = 18), uteroplacental insufficiency with adverse outcomes. An adverse outcome was defined as 1 or more of the following: (1) cesarean delivery because of fetal distress; (2) admission to the neonatal intensive care unit; (3) cord arterial pH less than 7.15 at birth; and (4) low 5-minute Apgar score (<7). The fetal urine production rate was obtained by serial bladder volume measurement using virtual organ computer-aided analysis. For bladder volume determination, we scanned the bladder in the 3-dimensional mode and defined the bladder surface contour in the reference plane, repeating the rotation of the reference plane with an angle of 30° and determining the surface contour on each plane. Statistical methods, including the Mann-Whitney U test, Fisher exact test, χ(2) test, and Kruskal-Wallis analysis of variance, were used. Group 3 had a lower mean fetal urine production rate than groups 1 and 2, whereas the urine production rate was not different between groups 1 and 2 (group 1, 49.0 mL/h; group 2, 59.4 mL/h; group 3, 20.7 mL/h; P < .001 between groups 1 and 3 and between groups 2 and 3). This difference between groups 2 and 3 remained significant after adjusting for the amniotic fluid index, umbilical artery Doppler pulsatility index, and presence of fetal growth restriction. Uteroplacental insufficiency cases with adverse perinatal outcomes had a lower fetal urine production rate than those without adverse outcomes. This difference might be used to predict adverse perinatal outcomes in uteroplacental insufficiency. © 2013 by the American Institute of Ultrasound in Medicine.

  11. Preoperative Bladder Urine Culture as a Predictor of Intraoperative Stone Culture Results: Clinical Implications and Relationship to Stone Composition

    PubMed Central

    Paonessa, Jessica E.; Gnessin, Ehud; Bhojani, Naeem; Williams, James C.; Lingeman, James E.

    2018-01-01

    Purpose We examine the relationship between urine and stone cultures in a large cohort of patients undergoing percutaneous stone removal and compare the findings in infectious vs metabolic calculi. Materials and Methods A total of 776 patients treated with percutaneous nephrolithotomy who had preoperative urine cultures and intraoperative stone cultures were included in the study. Statistical analysis used chi-square or logistic fit analysis as appropriate. Results Preoperative urine culture was positive in 352 patients (45.4%) and stone cultures were positive in 300 patients (38.7%). There were 75 patients (9.7%) with negative preoperative cultures who had positive stone cultures, and in patients with both cultures positive the organisms differed in 103 (13.3%). Gram-positive organisms predominated in preoperative urine and stone cultures. Conclusions Preoperative urine cultures in patients undergoing percutaneous nephrolithotomy are unreliable as there is a discordance with intraoperative stone cultures in almost a quarter of cases. There has been a notable shift toward gram-positive organisms in this cohort of patients. PMID:27038771

  12. Stability of miRNA in human urine supports its biomarker potential

    PubMed Central

    Mall, Christine; Rocke, David M; Durbin-Johnson, Blythe; Weiss, Robert H

    2013-01-01

    Aim miRNAs are showing utility as biomarkers in urologic disease, however, a rigorous evaluation of their stability in urine is lacking. Here, we evaluate the stability of miRNAs in urine under clinically relevant storage procedures. Materials & methods Eight healthy individuals provided clean catch urine samples that were stored at room temperature or at 4°C for 5 days, or subjected to ten freeze–thaw cycles at -80°C. For each condition, two miRNAs, miR-16 and miR-21, were quantitated by quantitative real-time PCR. Results All conditions demonstrated a surprising degree of stability of miRNAs in the urine: by the end of ten freeze–thaw cycles, 23–37% of the initial amount remained; over the 5-day period of storage at room temperature, 35% of the initial amount remained; and at 4°C, 42–56% of the initial amount remained. Both miRNAs also showed degradation at approximately the same rate. Conclusion miRNAs are relatively stable in urine under a variety of storage conditions, which supports their utility as urinary biomarkers. PMID:23905899

  13. Standard Specimen Reference Set: Colon — EDRN Public Portal

    Cancer.gov

    The Early Detection Research Network, Great Lakes-New England Clinical, Epidemiological and Validation Center (GLNE CVC) announces the availability of serum, plasma and urine samples for the early detection for colon cancer and validation studies.

  14. Copper and zinc level in biological samples from healthy subjects of vegetarian food habit in reference to community environment.

    PubMed

    Bhattacharya, R D; Patel, T S; Pandya, C B

    1985-01-01

    Many epidemiologists have found a correlation between copper and zinc in the community environment and diseases, such as myocardial and vascular pathologies, and diabetes. The purpose of this study was to investigate the total daily intake of these two metals in cooked food, drinking water and air and their respective levels in blood and urine. A chronobiological methodology has been adopted to establish the reference values of these two metals in biological samples. It has been observed that the daily intake of copper is within the recommended value, whereas its urinary excretion is high. The daily intake of zinc is below the recommended value and its urinary excretion is also high. Both the metals showed a temporal oscillation pattern in blood and urine. A possible chronic zinc deficiency has been anticipated in this particular ethnic group of vegetarian food habit.

  15. Influence of storage vial material on measurement of organophosphate flame retardant metabolites in urine.

    PubMed

    Carignan, Courtney C; Butt, Craig M; Stapleton, Heather M; Meeker, John D; Minguez-Alarcón, Lidia; Williams, Paige L; Hauser, Russ

    2017-08-01

    Use of organophosphate flame retardants (PFRs) has increased over the past decade with the phase out of polybrominated diphenyl ethers. Urinary metabolites of PFRs are used as biomarkers of exposure in epidemiologic research, which typically uses samples collected and stored in polypropylene plastic cryovials. However, a small study suggested that the storage vial material may influence reported concentrations. Therefore, we aimed to examine the influence of the storage vial material on analytical measurement of PFR urinary metabolites. Using urine samples collected from participants in the Environment and Reproductive Health (EARTH) Study, we analyzed the PFR metabolites in duplicate aliquots that were stored in glass and plastic vials (n = 31 pairs). Bis(1,3-dichloro-2-propyl) phosphate (BDCIPP), diphenyl phosphate (DPHP) and isopropyl-phenyl phenyl phosphate (ip-PPP) were detected in 98%, 97% and 87% of duplicates. We observed high correlations between glass-plastic duplicates for BDCIPP (r s  = 0.95), DPHP (r s  = 0.79) and ip-PPP (r s  = 0.82) (p < 0.0001). Urinary ip-PPP was an average of 0.04 ng/ml (p = 0.04) higher among samples stored in glass, with a mean relative difference of 14%. While this difference is statistically significant, it is small in magnitude. No differences were observed for BDCIPP or DPHP, however future research should seek to reduce the potential for type II error (false negatives). We conclude that storing urine samples in polypropylene plastic cryovials may result in slightly reduced concentrations of urinary ip-PPP relative to storage in glass vials and future research should seek to increase the sample size, reduce background variability and consider the material of the urine collection cup. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. High Resolution Size Analysis of Fetal DNA in the Urine of Pregnant Women by Paired-End Massively Parallel Sequencing

    PubMed Central

    Tsui, Nancy B. Y.; Jiang, Peiyong; Chow, Katherine C. K.; Su, Xiaoxi; Leung, Tak Y.; Sun, Hao; Chan, K. C. Allen; Chiu, Rossa W. K.; Lo, Y. M. Dennis

    2012-01-01

    Background Fetal DNA in maternal urine, if present, would be a valuable source of fetal genetic material for noninvasive prenatal diagnosis. However, the existence of fetal DNA in maternal urine has remained controversial. The issue is due to the lack of appropriate technology to robustly detect the potentially highly degraded fetal DNA in maternal urine. Methodology We have used massively parallel paired-end sequencing to investigate cell-free DNA molecules in maternal urine. Catheterized urine samples were collected from seven pregnant women during the third trimester of pregnancies. We detected fetal DNA by identifying sequenced reads that contained fetal-specific alleles of the single nucleotide polymorphisms. The sizes of individual urinary DNA fragments were deduced from the alignment positions of the paired reads. We measured the fractional fetal DNA concentration as well as the size distributions of fetal and maternal DNA in maternal urine. Principal Findings Cell-free fetal DNA was detected in five of the seven maternal urine samples, with the fractional fetal DNA concentrations ranged from 1.92% to 4.73%. Fetal DNA became undetectable in maternal urine after delivery. The total urinary cell-free DNA molecules were less intact when compared with plasma DNA. Urinary fetal DNA fragments were very short, and the most dominant fetal sequences were between 29 bp and 45 bp in length. Conclusions With the use of massively parallel sequencing, we have confirmed the existence of transrenal fetal DNA in maternal urine, and have shown that urinary fetal DNA was heavily degraded. PMID:23118982

  17. High rates of non-adherence to antihypertensive treatment revealed by high-performance liquid chromatography-tandem mass spectrometry (HP LC-MS/MS) urine analysis

    PubMed Central

    Tomaszewski, Maciej; White, Christobelle; Patel, Prashanth; Masca, Nicholas; Damani, Ravi; Hepworth, Joanne; Samani, Nilesh J; Gupta, Pankaj; Madira, Webster; Stanley, Adrian; Williams, Bryan

    2014-01-01

    Objectives Non-adherence to therapy is an important cause of suboptimal blood pressure control but few practical tools exist to accurately and routinely detect it. We used a simple urine-based assay to evaluate the prevalence of antihypertensive treatment non-adherence and its impact on blood pressure in a specialist hypertension centre. Methods 208 hypertensive patients (125 new referrals, 66 follow-up patients with inadequate blood pressure control and 17 renal denervation referrals) underwent assessment of antihypertensive drug intake using high-performance liquid chromatography-tandem mass spectrometry (HP LC-MS/MS) urine analysis at the time of clinical appointment. A total of 40 most commonly prescribed antihypertensive medications (or their metabolites) were screened for in spot urine samples. Results Overall, 25% of patients were totally or partially non-adherent to antihypertensive treatment (total non-adherence 10.1%, partial non-adherence 14.9%). The highest prevalence of partial and total non-adherence was among follow-up patients with inadequate blood pressure control (28.8%) and those referred for consideration of renal denervation (23.5%), respectively. There was a linear relationship between blood pressure and the numerical difference in detected/prescribed antihypertensive medications—every unit increase in this difference was associated with 3.0 (1.1) mm Hg, 3.1 (0.7) mm Hg and 1.9 (0.7) mm Hg increase in adjusted clinic systolic blood pressure, clinic diastolic blood pressure (DBP) and 24 h mean daytime DBP (p=0.0051, p=8.62×10−6, p=0.0057), respectively. Conclusions Non-adherence to blood pressure lowering therapy is common, particularly in patients with suboptimal blood pressure control and those referred for renal denervation. HP LC-MS/MS urine analysis could be used to exclude non-adherence and better stratify further investigations and intervention. PMID:24694797

  18. Development and validation of a simple and robust method for arsenic speciation in human urine using HPLC/ICP-MS.

    PubMed

    Sen, Indranil; Zou, Wei; Alvaran, Josephine; Nguyen, Linda; Gajek, Ryszard; She, Jianwen

    2015-01-01

    In order to better distinguish the different toxic inorganic and organic forms of arsenic (As) exposure in individuals, we have developed and validated a simple and robust analytical method for determining the following six As species in human urine: arsenous (III) acid (As-III), As (V) acid, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine (AsB), and arsenocholine. In this method, human urine is diluted using a pH 5.8 buffer, separation is performed using an anion exchange column with isocratic HPLC, and detection is achieved using inductively coupled plasma-MS. The method uses a single mobile phase consisting of low concentrations of both phosphate buffer (5 mM) and ammonium nitrate salt (5 mM) at pH 9.0; this minimizes the column equilibration time and overcomes challenges with separation between AsB and As-III. In addition, As-III oxidation is prevented by degassing the sample preparation buffer at pH 5.8, degassing the mobile phase online at pH 9.0, and by the use of low temperature (-70 °C) and flip-cap airtight tubes for long term storage of samples. The method was validated using externally provided reference samples. Results were in agreement with target values at varying concentrations and successfully passed external performance test criteria. Internal QC samples were prepared and repeatedly analyzed to assess the method's long-term precision, and further analyses were completed on anonymous donor urine to assess the quality of the method's baseline separation. Results from analyses of external reference samples agreed with target values at varying concentrations, and results from precision studies yielded absolute CV values of 3-14% and recovery from 82 to 115% for the six As species. Analysis of anonymous donor urine confirmed the well-resolved baseline separation capabilities of the method for real participant samples.

  19. Diagnostic accuracy and applicability of a PCR system for the detection of Schistosoma mansoni DNA in human urine samples from an endemic area.

    PubMed

    Enk, Martin Johannes; Oliveira e Silva, Guilherme; Rodrigues, Nilton Barnabé

    2012-01-01

    Schistosomiasis caused by Schistosoma mansoni, one of the most neglected human parasitoses in Latin America and Africa, is routinely confirmed by microscopic visualization of eggs in stool. The main limitation of this diagnostic approach is its lack of sensitivity in detecting individual low worm burdens and consequently data on infection rates in low transmission settings are little reliable. According to the scientific literature, PCR assays are characterized by high sensitivity and specificity in detecting parasite DNA in biological samples. A simple and cost effective extraction method for DNA of Schistosoma mansoni from urine samples in combination with a conventional PCR assay was developed and applied in an endemic area. This urine based PCR system was tested for diagnostic accuracy among a population of a small village in an endemic area, comparing it to a reference test composed of three different parasitological techniques. The diagnostic parameters revealed a sensitivity of 100%, a specificity of 91.20%, positive and negative predictive values of 86.25% and 100%, respectively, and a test accuracy of 94.33%. Further statistical analysis showed a k index of 0.8806, indicating an excellent agreement between the reference test and the PCR system. Data obtained from the mouse model indicate the infection can be detected one week after cercariae penetration, opening a new perspective for early detection and patient management during this stage of the disease. The data indicate that this innovative PCR system provides a simple to handle and robust diagnostic tool for the detection of S. mansoni DNA from urine samples and a promising approach to overcome the diagnostic obstacles in low transmission settings. Furthermore the principals of this molecular technique, based on the examination of human urine samples may be useful for the diagnosis of other neglected tropical diseases that can be detected by trans-renal DNA.

  20. A simple micro-photometric method for urinary iodine determination.

    PubMed

    Grimm, Gabriele; Lindorfer, Heidelinde; Kieweg, Heidi; Marculescu, Rodrig; Hoffmann, Martha; Gessl, Alois; Sager, Manfred; Bieglmayer, Christian

    2011-10-01

    Urinary iodide concentration (UIC) is useful to evaluate nutritional iodine status. In clinical settings UIC helps to exclude blocking of the thyroid gland by excessive endogenous iodine, if diagnostic or therapeutic administration of radio-iodine is indicated. Therefore, this study established a simple test for the measurement of UIC. UIC was analyzed in urine samples of 200 patients. Samples were pre-treated at 95°C for 45 min with ammonium persulfate in a thermal cycler, followed by a photometric Sandell-Kolthoff reaction (SK) carried out in microtiter plates. For method comparison, UIC was analyzed in 30 samples by inductivity coupled plasma mass spectro-metry (ICP-MS) as a reference method. Incubation conditions were optimized concerning recovery. The photometric test correlated well to the reference method (SK=0.91*ICP-MS+1, r=0.962) and presented with a functional sensitivity of 20 μg/L. UIC of patient samples ranged from <20 to 750 μg/L (median 110 μg/L); 90% of the urine samples had iodide concentrations below 210 μg/L. The modified SK-test takes approximately 90 min for analyses of 20 urine samples compared with 27 h for ICP-MS. The photometric test provides satisfactory results and can be performed with the basic equipment of a clinical laboratory.

  1. Chemical Carcinogen-Induced Changes in tRNA Metabolism in Human Cells.

    DTIC Science & Technology

    1983-11-30

    expression of carcinogenesis is postulated. MATERIALS AND METHODS Nucleosldem In urine were resolved and quantitated using reversed-phase high performance...liquid chromatography 8 following clarification on a boronate colun 5 . Quantitation was relative to the creatinine content in random urine specimens 7...Patients Urinary nucleoside excretion has been quantitated for patients with nasopharyngeal carcinoma (NPC) and leukemia, and the results nLn m l

  2. Impact of probability estimation on frequency of urine culture requests in ambulatory settings.

    PubMed

    Gul, Naheed; Quadri, Mujtaba

    2012-07-01

    To determine the perceptions of the medical community about urine culture in diagnosing urinary tract infections. The cross-sectional survey based of consecutive sampling was conducted at Shifa International Hospital, Islamabad, on 200 doctors, including medical students of the Shifa College of Medicine, from April to October 2010. A questionnaire with three common clinical scenarios of low, intermediate and high pre-test probability for urinary tract infection was used to assess the behaviour of the respondents to make a decision for urine culture test. The differences between the reference estimates and the respondents' estimates of pre- and post-test probability were assessed. The association of estimated probabilities with the number of tests ordered was also evaluated. The respondents were also asked about the cost effectiveness and safety of urine culture and sensitivity. Data was analysed using SPSS version 15. In low pre-test probability settings, the disease probability was over-estimated, suggesting the participants' inability to rule out the disease. The post-test probabilities were, however, under-estimated by the doctors as compared to the students. In intermediate and high pre-test probability settings, both over- and underestimation of probabilities were noticed. Doctors were more likely to consider ordering the test as the disease probability increased. Most of the respondents were of the opinion that urine culture was a cost-effective test and there was no associated potential harm. The wide variation in the clinical use of urine culture necessitates the formulation of appropriate guidelines for the diagnostic use of urine culture, and application of Bayesian probabilistic thinking to real clinical situations.

  3. Genetics Home Reference: lysinuric protein intolerance

    MedlinePlus

    ... abnormally large amount of these amino acids in urine. A shortage of lysine, arginine, and ornithine disrupts many vital functions. Arginine and ornithine are involved in a cellular process called the urea cycle, which processes excess nitrogen (in the form ...

  4. Glycerophosphate is interchangeable with inorganic phosphate in terms of safety and serum pharmacokinetics.

    PubMed

    Topp, Heinrich; Hochfeld, Olena; Bark, Staffan; Grossmann, Matthias; Joukhadar, Christian; Westphal, Martin; Straatsma, Harald; Rothenburger, Markus

    2011-01-01

    The primary aim of the present investigation was to determine and compare the pharmacokinetic (PK) profiles of inorganic phosphate in serum and urine after intravenous administration of sodium glycerophosphate and inorganic sodium phosphate. Additionally, study product safety profiles were evaluated. In total, 27 healthy, white volunteers (17 male/10 female) were enrolled in this double-blinded, randomized, 2-sequence, crossover study and were assigned to receive an organic test drug (sodium glycerophosphate) and an inorganic reference preparation (sodium phosphate) on 2 occasions. Validated analytical methods were used, and concentrations of total inorganic phosphate in serum and urine were determined over 24 h following a single 4-hour continuous intravenous infusion of test and reference drugs at a dose of 80 mmol. Study days were separated by washout periods of 7 days. An analysis of variance, based on population means and 90% confidence intervals (CIs), was used for testing bioequivalence (BE; range 0.8-1.25) between investigational products. The geometric means of the ratio of the point estimates and corresponding 90% CIs for the area under the concentration-versus-time curve of inorganic serum phosphate from 0 to 24 h (AUC(0-24)), the phosphate's maximum concentration in serum (C(max)) and the total amount of inorganic phosphate excreted in urine over 24 h corrected for individual baseline values (Ae(0-24 bc)) were estimated. The test/reference ratios for inorganic phosphate were 1.04 (CI 1.00-1.07), 0.85 (CI 0.84-0.87) and 0.84 (CI 0.77-0.92) for AUC(0-24), C(max) in serum and Ae(0-24 bc) in urine, respectively. Hence, standard BE criteria were met for AUC(0-24) and C(max) in serum, while Ae(0-24 bc) marginally failed to demonstrate BE. After drug administration, a total of 15 subjects reported the occurrence of at least 1 treatment emergent adverse event (AE). All AEs were classified as mild to moderate in severity, and the two treatment groups were equally affected. No serious AEs occurred. The serum PK profiles of inorganic phosphate were almost superimposable following intravenous administration of equimolar doses of test and reference drugs. Thus, we conclude that the two study drugs are essentially similar in terms of serum PK profiles, safety and tolerability. Copyright © 2011 S. Karger AG, Basel.

  5. Black market products confiscated in Norway 2011-2014 compared to analytical findings in urine samples.

    PubMed

    Hullstein, Ingunn R; Malerod-Fjeld, Helle; Dehnes, Yvette; Hemmersbach, Peter

    2015-01-01

    Doping agents are widely and illicitly distributed through the Internet. Analysis of these preparations is useful in order to monitor the availability of prohibited substances on the market, and more importantly to predict which substances are expected to be found in urine samples collected from athletes and to aid clinical and forensic investigations. Based on a close collaboration with the Norwegian police and the Norwegian custom authorities, the Norwegian Doping Control Laboratory has performed analyses of confiscated material suspected of containing doping agents. The analyses were performed using gas chromatography (GC) and liquid chromatography (LC) combined with mass spectrometry (MS). The majority (67%) of the analyzed black market products contained anabolic- androgenic steroids (AAS) as expected, whereas peptide- and protein-based doping substances were identified in 28% of the preparations. The Norwegian Doping Control Laboratory receives samples collected from recreational and elite athletes in addition to samples collected in clinical and forensic investigations. The findings in the seized material reflected the findings in the urine samples analyzed regarding the anabolic steroids. Thus, analyzing material seized in Norway may give a good indication of doping agents available on the local market. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Distribution of chloramphenicol to tissues, plasma and urine in pigs after oral intake of low doses.

    PubMed

    Aspenström-Fagerlund, Bitte; Nordkvist, Erik; Törnkvist, Anna; Wallgren, Per; Hoogenboom, Ron; Berendsen, Bjorn; Granelli, Kristina

    2016-09-01

    Toxic effects of chloramphenicol in humans caused the ban for its use in food-producing animals in the EU. A minimum required performance level (MRPL) was specified for chloramphenicol at 0.3 μg kg(-1) for various matrices, including urine. In 2012, residues of chloramphenicol were found in pig urine and muscle without signs of illegal use. Regarding its natural occurrence in straw, it was hypothesised that this might be the source, straw being compulsory for use as bedding material for pigs in Sweden. Therefore, we investigated if low daily doses of chloramphenicol (4, 40 and 400 μg/pig) given orally during 14 days could result in residues in pig tissues and urine. A dose-related increase of residues was found in muscle, plasma, kidney and urine (showing the highest levels), but no chloramphenicol was found in the liver. At the lowest dose, residues were below the MRPL in all tissues except in the urine. However, in the middle dose, residues were above the MRPL in all tissues except muscle, and at the highest dose in all matrices. This study proves that exposure of pigs to chloramphenicol in doses occurring naturally in straw could result in residues above the MRPL in plasma, kidney and especially urine.

  7. Biochemical marker reference values across pediatric, adult, and geriatric ages: establishment of robust pediatric and adult reference intervals on the basis of the Canadian Health Measures Survey.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David

    2015-08-01

    Biological covariates such as age and sex can markedly influence biochemical marker reference values, but no comprehensive study has examined such changes across pediatric, adult, and geriatric ages. The Canadian Health Measures Survey (CHMS) collected comprehensive nationwide health information and blood samples from children and adults in the household population and, in collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), examined biological changes in biochemical markers from pediatric to geriatric age, establishing a comprehensive reference interval database for routine disease biomarkers. The CHMS collected health information, physical measurements, and biosamples (blood and urine) from approximately 12 000 Canadians aged 3-79 years and measured 24 biochemical markers with the Ortho Vitros 5600 FS analyzer or a manual microplate. By use of CLSI C28-A3 guidelines, we determined age- and sex-specific reference intervals, including corresponding 90% CIs, on the basis of specific exclusion criteria. Biochemical marker reference values exhibited dynamic changes from pediatric to geriatric age. Most biochemical markers required some combination of age and/or sex partitioning. Two or more age partitions were required for all analytes except bicarbonate, which remained constant throughout life. Additional sex partitioning was required for most biomarkers, except bicarbonate, total cholesterol, total protein, urine iodine, and potassium. Understanding the fluctuations in biochemical markers over a wide age range provides important insight into biological processes and facilitates clinical application of biochemical markers to monitor manifestation of various disease states. The CHMS-CALIPER collaboration addresses this important evidence gap and allows the establishment of robust pediatric and adult reference intervals. © 2015 American Association for Clinical Chemistry.

  8. [Comparison and evaluation of the Binax EIA and Biotest EIA urinary antigen kits for detection of Legionella pneumophila antigen in urine samples].

    PubMed

    Rastawicki, Waldemar; Rokosz, Natalia; Jagielski, Marek

    2011-01-01

    The Binax and the Biotest urinary antigen kits for detection of L. pneumophila antigen were compared by testing of selected 67 urine samples obtained from EWGLI as reference samples in External Quality Assessment Scheme. Thirty nine were positive with the Binax kit (100% of sensitivity), and 33 were positive with the Biotest (84.6% of sensitivity). The test specificities were 100% for the both kits. It was concluded that the Binax kit was more suitable for the routine diagnosis of Legionella infections than the Biotest kit.

  9. PCA3 Reference Set Application: T2-Erg-Martin Sanda-Emory (2014) — EDRN Public Portal

    Cancer.gov

    We hypothesize that combining T2:erg (T2:erg) fusion and PCA3 detection in urine collected after digital rectal exam can improve the specificity of identifying clinically significant prostate cancer presence over the standard PSA and DRE. To address this hypothesis we propose to validate the performance of the urinary T2:erg in a multiplex model predicting the diagnosis of clinically significant prostate cancer on subsequent prostate biopsy using post-DRE pre biopsy urine specimens from a cohort of 900 men on the EDRN’s PCA3 trial.

  10. Improving the Diagnosis and Treatment of Urinary Tract Infection in Young Children in Primary Care: Results from the DUTY Prospective Diagnostic Cohort Study

    PubMed Central

    Hay, Alastair D.; Sterne, Jonathan A. C.; Hood, Kerenza; Little, Paul; Delaney, Brendan; Hollingworth, William; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Lawton, Michael; Busby, John; Pickles, Timothy; Birnie, Kate; O’Brien, Kathryn; Waldron, Cherry-Ann; Dudley, Jan; Van Der Voort, Judith; Downing, Harriet; Thomas-Jones, Emma; Harman, Kim; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Butler, Christopher C.

    2016-01-01

    PURPOSE Up to 50% of urinary tract infections (UTIs) in young children are missed in primary care. Urine culture is essential for diagnosis, but urine collection is often difficult. Our aim was to derive and internally validate a 2-step clinical rule using (1) symptoms and signs to select children for urine collection; and (2) symptoms, signs, and dipstick testing to guide antibiotic treatment. METHODS We recruited acutely unwell children aged under 5 years from 233 primary care sites across England and Wales. Index tests were parent-reported symptoms, clinician-reported signs, urine dipstick results, and clinician opinion of UTI likelihood (clinical diagnosis before dipstick and culture). The reference standard was microbiologically confirmed UTI cultured from a clean-catch urine sample. We calculated sensitivity, specificity, and area under the receiver operator characteristic (AUROC) curve of coefficient-based (graded severity) and points-based (dichotomized) symptom/sign logistic regression models, and we then internally validated the AUROC using bootstrapping. RESULTS Three thousand thirty-six children provided urine samples, and culture results were available for 2,740 (90%). Of these results, 60 (2.2%) were positive: the clinical diagnosis was 46.6% sensitive, with an AUROC of 0.77. Previous UTI, increasing pain/crying on passing urine, increasingly smelly urine, absence of severe cough, increasing clinician impression of severe illness, abdominal tenderness on examination, and normal findings on ear examination were associated with UTI. The validated coefficient- and points-based model AUROCs were 0.87 and 0.86, respectively, increasing to 0.90 and 0.90, respectively, by adding dipstick nitrites, leukocytes, and blood. CONCLUSIONS A clinical rule based on symptoms and signs is superior to clinician diagnosis and performs well for identifying young children for noninvasive urine sampling. Dipstick results add further diagnostic value for empiric antibiotic treatment. PMID:27401420

  11. Improving the Diagnosis and Treatment of Urinary Tract Infection in Young Children in Primary Care: Results from the DUTY Prospective Diagnostic Cohort Study.

    PubMed

    Hay, Alastair D; Sterne, Jonathan A C; Hood, Kerenza; Little, Paul; Delaney, Brendan; Hollingworth, William; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Lawton, Michael; Busby, John; Pickles, Timothy; Birnie, Kate; O'Brien, Kathryn; Waldron, Cherry-Ann; Dudley, Jan; Van Der Voort, Judith; Downing, Harriet; Thomas-Jones, Emma; Harman, Kim; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Butler, Christopher C

    2016-07-01

    Up to 50% of urinary tract infections (UTIs) in young children are missed in primary care. Urine culture is essential for diagnosis, but urine collection is often difficult. Our aim was to derive and internally validate a 2-step clinical rule using (1) symptoms and signs to select children for urine collection; and (2) symptoms, signs, and dipstick testing to guide antibiotic treatment. We recruited acutely unwell children aged under 5 years from 233 primary care sites across England and Wales. Index tests were parent-reported symptoms, clinician-reported signs, urine dipstick results, and clinician opinion of UTI likelihood (clinical diagnosis before dipstick and culture). The reference standard was microbiologically confirmed UTI cultured from a clean-catch urine sample. We calculated sensitivity, specificity, and area under the receiver operator characteristic (AUROC) curve of coefficient-based (graded severity) and points-based (dichotomized) symptom/sign logistic regression models, and we then internally validated the AUROC using bootstrapping. Three thousand thirty-six children provided urine samples, and culture results were available for 2,740 (90%). Of these results, 60 (2.2%) were positive: the clinical diagnosis was 46.6% sensitive, with an AUROC of 0.77. Previous UTI, increasing pain/crying on passing urine, increasingly smelly urine, absence of severe cough, increasing clinician impression of severe illness, abdominal tenderness on examination, and normal findings on ear examination were associated with UTI. The validated coefficient- and points-based model AUROCs were 0.87 and 0.86, respectively, increasing to 0.90 and 0.90, respectively, by adding dipstick nitrites, leukocytes, and blood. A clinical rule based on symptoms and signs is superior to clinician diagnosis and performs well for identifying young children for noninvasive urine sampling. Dipstick results add further diagnostic value for empiric antibiotic treatment. © 2016 Annals of Family Medicine, Inc.

  12. High Throughput Method of Extracting and Counting Strontium-90 in Urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shkrob, I.; Kaminski, M.; Mertz, C.

    2016-03-01

    A method has been developed for the rapid extraction of Sr-90 from the urine of individuals exposed to radiation in a terrorist attack. The method employs two chromatographic ion-exchange materials: Diphonix resin and Sr resin, both of which are commercially available. The Diphonix resin reduces the alkali ion concentrations below 10 mM, and the Sr resin concentrates and decontaminates strontium-90. Experimental and calculational data are given for a variety of test conditions. On the basis of these results, a flowsheet has been developed for the rapid concentration and extraction of Sr-90 from human urine samples for subsequent beta-counting.

  13. Use of DSC and DMA Techniques to Help Investigate a Material Anomaly for PTFE Used in Processing a Piston Cup for the Urine Processor Assembly (UPA) on International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    Wingard, Doug

    2010-01-01

    Human urine and flush water are eventually converted into drinking water with the Urine Processor Assembly (UPA) aboard the International Space Station (ISS). This conversion is made possible through the Distillation Assembly (DA) of the UPA. One component of the DA is a molded circular piston cup made of virgin polytetrafluoroethylene (PTFE). The piston cup is assembled to a titanium component using eight fasteners and washers. Molded PTFE produced for spare piston cups in the first quarter of 2010 was different in appearance and texture, and softer than material molded for previous cups. For the suspect newer PTFE material, cup fasteners were tightened to only one-half the required torque value, yet the washers embedded almost halfway into the material. The molded PTFE used in the DA piston cup should be Type II, based on AMS 3667D and ASTM D4894 specifications. The properties of molded PTFE are considerably different between Type I and II materials. Engineers working with the DA thought that if Type I PTFE was molded by mistake instead of Type II material, that could have resulted in the anomalous material properties. Typically, the vendor molds flat sheet PTFE from the same material lot used to mold the piston cups, and tensile testing as part of quality control should verify that the PTFE is Type II material. However, for this discrepant lot of material, such tensile data was not available. Differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) were two of the testing techniques used at the NASA/Marshall Space Flight Center (MSFC) to investigate the anomaly for the PTFE material. Other techniques used on PTFE specimens were: Shore D hardness testing, tensile testing on dog bone specimens and a qualitative estimation of porosity by optical and scanning electron microscopy.

  14. Sensitive spectrofluorimetric determination of tizanidine in pharmaceutical preparations, human plasma and urine through derivatization with dansyl chloride.

    PubMed

    Ulu, Sevgi Tatar

    2012-01-01

    A sensitive spectrofluorimetric method was developed for the determination of tizanidine in human plasma, urine and pharmaceutical preparations. The method is based on reaction of tizanidine with 1-dimethylaminonaphthalene-5-sulphonyl chloride (dansyl chloride) in an alkaline medium to form a highly fluorescent derivative that was measured at 511 nm after excitation at 383 nm. The different experimental parameters affecting the fluorescence intensity of tizanidine was carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the ranges 50-500 and 20-300 ng/mL for plasma and urine, respectively, detection limits of 1.81 and 0.54 ng/mL and quantification limits of 5.43 and 1.62 ng/mL for plasma and urine, respectively. The method presents good performance in terms of linearity, detection and quantification limits, precision, accuracy and specificity. The proposed method was successfully applied for the determination of tizanidine in pharmaceutical preparations. The results obtained were compared with a reference method, using t- and F-tests. Copyright © 2011 John Wiley & Sons, Ltd.

  15. An Inexpensive, Point-of-Care Urine Test for Bladder Cancer in Patients Undergoing Hematuria Evaluation.

    PubMed

    Acharya, Abhinav P; Theisen, Kathryn M; Correa, Andres; Meyyappan, Thiagarajan; Apfel, Abraham; Sun, Tao; Tarin, Tatum V; Little, Steven R

    2017-11-01

    Although hematuria (blood in urine) is the most common symptom of bladder cancer, 70-98% of hematuria cases are benign. These hematuria patients unnecessarily undergo costly, invasive, and expensive evaluation for bladder cancer. Therefore, there remains a need for noninvasive office-based tests that can rapidly and reliably rule out bladder cancer in patients undergoing hematuria evaluation. Herein, a clinical assay for matrix metalloproteinases ("Ammps") is presented, which generates a visual signal based on the collagenase activity (in urine of patients) on the Ammps substrates. Ammps substrates are generated by crosslinking gelatin with Fe(II) chelated alginate nanoparticles, which precipitate in urine samples. The cleavage of gelatin-conjugated alginate (Fe(II)) nanoparticles by collagenases generates free-floating alginate (Fe(II)) nanoparticles that participate in Fenton's reaction to generate a visual signal. In a pilot study of 88 patients, Ammps had 100% sensitivity, 85% specificity, and a negative predictive value (NPV) of 100% for diagnosing bladder cancer. This high NPV can be useful in ruling out bladder cancer in patients referred for hematuria evaluation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Detection of flunixin in greyhound urine by a kinetic enzyme-linked immunosorbent assay.

    PubMed

    Brady, T C; Yang, T J; Hyde, W G; Kind, A J; Hill, D W

    1997-01-01

    A two-step kinetic enzyme-linked immunosorbent assay was developed to detect the presence of flunixin in the urine of greyhound dogs. The assay system was developed using polyclonal antiflunixin antisera, a rabbit albumin-flunixin conjugate adsorbed onto polystyrene microtiter strips, and flunixin reference standards for calibration. The assay parameters were optimized and the performance characteristics were determined. The quantitative intra- and inter-run precisions (%CV) of the analysis of replicate (n = 10) flunixin-spiked urine samples were 9.9-12.5% and 10.2-13.6%, respectively. The linear dynamic range was 1-100 ng/mL, and the quantitative accuracy, as determined by calculation of percent error of measured flunixin in flunixin-spiked drug-free greyhound urine, was -16% to +14% over this range. The I50 of the ELISA was 17.3 ng/mL. The limit of detection was 25 ng/mL in greyhound urine. The reactivity in the assay system relative to flunixin (100%) was 147% for flunixin glucuronide, 25% for clonixin, and 5% for niflumic acid. The ELISA was capable of detecting total flunixin for up to 72 h in dogs administered flunixin at 0.55 mg/kg orally and up to 96 h in a dog that was administered flunixin at 1.0 mg/kg orally.

  17. Detection and sequencing of West Nile virus RNA from human urine and serum samples during the 2014 seasonal period.

    PubMed

    Nagy, Anna; Bán, Enikő; Nagy, Orsolya; Ferenczi, Emőke; Farkas, Ágnes; Bányai, Krisztián; Farkas, Szilvia; Takács, Mária

    2016-07-01

    West Nile virus, a widely distributed mosquito-borne flavivirus, is responsible for numerous animal and human infections in Europe, Africa and the Americas. In Hungary, the average number of human infections falls between 10 and 20 cases each year. The severity of clinically manifesting infections varies widely from the milder form of West Nile fever to West Nile neuroinvasive disease (WNND). In routine laboratory diagnosis of human West Nile virus infections, serological methods are mainly applied due to the limited duration of viremia. However, recent studies suggest that detection of West Nile virus RNA in urine samples may be useful as a molecular diagnostic test for these infections. The Hungarian National Reference Laboratory for Viral Zoonoses serologically confirmed eleven acute human infections during the 2014 seasonal period. In three patients with neurological symptoms, viral RNA was detected from both urine and serum specimens, albeit for a longer period and in higher copy numbers with urine. Phylogenetic analysis of the NS3 genomic region of three strains and the complete genome of one selected strain demonstrated that all three patients had lineage-2 West Nile virus infections. Our findings reaffirm the utility of viral RNA detection in urine as a molecular diagnostic procedure for diagnosis of West Nile virus infections.

  18. Occurance of Staphylococcus nepalensis strains in different sources including human clinical material.

    PubMed

    Nováková, Dana; Pantůcek, Roman; Petrás, Petr; Koukalová, Dagmar; Sedlácek, Ivo

    2006-10-01

    Five isolates of coagulase-negative staphylococci were obtained from human urine, the gastrointestinal tract of squirrel monkeys, pig skin and from the environment. All key biochemical characteristics of the tested strains corresponded with the description of Staphylococcus xylosus species. However, partial 16S rRNA gene sequences obtained from analysed strains corresponded with those of Staphylococcus nepalensis reference strains, except for two strains which differed in one residue. Ribotyping with EcoRI and HindIII restriction enzymes, whole cell protein profile analysis performed by SDS-PAGE and SmaI macrorestriction analysis were used for more precise characterization and identification of the analysed strains. Obtained results showed that EcoRI and HindIII ribotyping and whole cell protein fingerprinting are suitable and reliable methods for the differentiation of S. nepalensis strains from the other novobiocin resistant staphylococci, whereas macrorestriction analysis was found to be a good tool for strain typing. The isolation of S. nepalensis is sporadic, and according to our best knowledge this study is the first report of the occurrence of this species in human clinical material as well as in other sources.

  19. Immunodetection and molecular determination of visceral and cutaneous Leishmania infection using patients' urine.

    PubMed

    Mirzaei, Asad; Ahmadipour, Fereshteh; Cannet, Arnaud; Marty, Pierre; Delaunay, Pascal; Perrin, Pascale; Dorkeld, Franck; Sereno, Denis; Akhoundi, Mohammad

    2018-05-27

    The diagnosis of leishmaniasis relies mainly on the use of invasive processes, to collect the biological material for detecting Leishmania parasites. Body fluids, which can be collected by non-invasive process, would greatly facilitate the leishmaniasis diagnosis. In the present study, we investigated the potency of urine immunoblotting to diagnose cutaneous and visceral leishmaniasis and we compared with routine molecular methods. A total of 80 samples, including 40 sera and their 40 corresponding urine samples were collected from 37 suspected patients with cutaneous and visceral leishmaniasis, and 3 healthy individuals (as control), in Ilam and Ardabil provinces of Iran. All sera and urine samples were analyzed, using immunoblotting. The confirmation of leishmaniasis infection was performed, using conventional and quantitative PCRs as well as by sequencing the amplicons. Among 37 suspected patients, 23 patients presented cutaneous lesions (CL) and 14 exhibited clinical symptoms reminiscent of visceral leishmaniasis (L. infantum). Among cutaneous patients, 15 were positive for zoonotic cutaneous leishmaniasis (L. major), and eight for anthroponotic cutaneous leishmaniasis (L. tropica). Molecular quantification of Leishmania parasites was performed on sera, urines and cutaneous biopsies of CL and VL patients, demonstrating that parasite load is lower in urines, compared to sera or biopsy. DNA can be detected in 20 out of 23 (86.9%) CL urine samples and in 13 out of 14 (92.8%) VL urine samples. Immunodetection analysis demonstrates that 22 out of 23 (95.6%) sera from CL patients and all patients suspected with VL are positive. For urine samples, 18 out of 23 (78.2%) urine of CL patients and 13 out of 14 (92.8%) urine of VL patients were positive, using Western blot. Therefore, immunodetection and molecular analysis using urine samples can be used as a diagnostic tool for surveying cutaneous and visceral leishmaniasis. Copyright © 2017. Published by Elsevier B.V.

  20. Determination of actinides in urine and fecal samples

    DOEpatents

    McKibbin, Terry T.

    1993-01-01

    A method of determining the radioactivity of specific actinides that are carried in urine or fecal sample material is disclosed. The samples are ashed in a muffle furnace, dissolved in an acid, and then treated in a series of steps of reduction, oxidation, dissolution, and precipitation, including a unique step of passing a solution through a chloride form anion exchange resin for separation of uranium and plutonium from americium.

  1. Determination of actinides in urine and fecal samples

    DOEpatents

    McKibbin, T.T.

    1993-03-02

    A method of determining the radioactivity of specific actinides that are carried in urine or fecal sample material is disclosed. The samples are ashed in a muffle furnace, dissolved in an acid, and then treated in a series of steps of reduction, oxidation, dissolution, and precipitation, including a unique step of passing a solution through a chloride form anion exchange resin for separation of uranium and plutonium from americium.

  2. Electrolytic pretreatment of urine

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Electrolysis has been under evaluation for several years as a process to pretreat urine for ultimate recovery of potable water in manned spacecraft applications. The conclusions that were drawn from this investigation are the following: (1) A platinum alloy containing 10 percent rhodium has been shown to be an effective, corrosion-resistant anode material for the electrolytic pretreatment of urine. Black platinum has been found to be suitable as a cathode material. (2) The mechanism of the reactions occurring during the electrolysis of urine is two-stage: (a) a total Kjeldahl nitrogen and total organic carbon (TOC) removal in the first stage is the result of electrochemical oxidation of urea to CO2, H2O, and ammonia followed by chloride interaction to produce N2 from ammonia, (b) after the urea has been essentially removed and the chloride ions have no more ammonia to interact with, the chloride ions start to oxidize to higher valence states, thus producing perchlorates. (3) Formation of perchlorates can be suppressed by high/low current operation, elevated temperature, and pH adjustment. (4) UV-radiation showed promise in assisting electrolytic TOC removal in beaker tests, but was not substantiated in limited single cell testing. This may have been due to non-optimum configurations of the single cell test rig and the light source.

  3. Magnetic dispersive solid-phase extraction based on modified magnetic nanoparticles for the detection of cocaine and cocaine metabolites in human urine by high-performance liquid chromatography-mass spectrometry.

    PubMed

    Yang, Feiyu; Zou, Yun; Ni, Chunfang; Wang, Rong; Wu, Min; Liang, Chen; Zhang, Jiabin; Yuan, Xiaoliang; Liu, Wenbin

    2017-11-01

    An easy-to-handle magnetic dispersive solid-phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe 3 O 4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high-performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid-phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09-1.10 ng/mL. The proposed magnetic dispersive solid-phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. A prototype urine collection device for female aircrew

    NASA Technical Reports Server (NTRS)

    Bisson, Roger U.; Delger, Karlyna L.

    1993-01-01

    Women are gaining increased access to small military cockpits. This shift has stimulated the search for practical urine containment and disposal methods for female aircrew. There are no external urine collection devices (UCD) for women that are comfortable, convenient, and leak free. We describe a prototype UCD that begins to meet this need. Materials used to make custom aviator masks were adapted to mold a perineal mask. First, a perineal cast (negative) was used to make a mold (positive). Next, a perineal mask made of wax was formed to fit the positive mold. Finally, a soft, pliable perineal mask was fabricated using the wax model as a guide. The prototype was tested for comfort, fit, and leakage. In the sitting position, less than 5 cc of urine leakage occurred with each 600 cc of urine collected. Comfort was mostly satisfactory, but ambulation was limited and the outlet design could lead to kinking and obstruction. We concluded that a perineal mask may serve as a comfortable and functional external UCD acceptable for use by females in confined environments. Changes are needed to improve comfort, fit, and urine drainage. Integration into cockpits, pressure suits, chemical defense gear, and environments where access to relief facilities is restricted is planned.

  5. Diagnostic Value of the Urine Mucus Test in Childhood Masturbation among Children below 12 Years of Age: A Cross-Sectional Study from Iran

    PubMed Central

    Doust, Zarin Keihani; Shariat, Mamak; Zabandan, Neda; Tabrizi, Aidin; Tehrani, Fatemeh

    2016-01-01

    Background: Childhood masturbation (CM) is considered a variant of normal sexual behavior; however, it is commonly misdiagnosed as epilepsy and movement disorders. As the first study from Iran, we analyzed a large population of infants and children with CM in a case-control study and evaluated the value of mucus in urine analysis as an alternative diagnostic tool for CM. Methods: A total of 623 children referred to the Pediatric Neurology Clinic of Imam Khomeini Hospital for an evaluation of seizure or movement disorders were studied between 2008 and 2011. Totally, 359 children were found to have masturbatory behaviors (Group A) and the rest (264) were assigned to Group B. CM was diagnosed by direct observation. Collected data comprised demographic characteristics, clinical and neurodevelopmental examinations, laboratory findings (particularly urine analysis), and electrocardiography. Results: The age of the children with CM was below 12 years old, and the girl-to-boy ratio was 7:1. Mucus in urine was positive in 357 (99.44%) children in Group A and 22 (8.3%) in Group B (P<0.001). A significant correlation was found between the presence of mucus in urine and masturbatory behaviors (P<0.001). Conclusion: Our findings suggest that the presence of mucus in urine can be used as an alternative laboratory test in children with CM below 12 years old and even in infants (≤24 months old). Further studies are needed to confirm the results. PMID:27365549

  6. Diagnostic Value of the Urine Mucus Test in Childhood Masturbation among Children below 12 Years of Age: A Cross-Sectional Study from Iran.

    PubMed

    Doust, Zarin Keihani; Shariat, Mamak; Zabandan, Neda; Tabrizi, Aidin; Tehrani, Fatemeh

    2016-07-01

    Childhood masturbation (CM) is considered a variant of normal sexual behavior; however, it is commonly misdiagnosed as epilepsy and movement disorders. As the first study from Iran, we analyzed a large population of infants and children with CM in a case-control study and evaluated the value of mucus in urine analysis as an alternative diagnostic tool for CM. A total of 623 children referred to the Pediatric Neurology Clinic of Imam Khomeini Hospital for an evaluation of seizure or movement disorders were studied between 2008 and 2011. Totally, 359 children were found to have masturbatory behaviors (Group A) and the rest (264) were assigned to Group B. CM was diagnosed by direct observation. Collected data comprised demographic characteristics, clinical and neurodevelopmental examinations, laboratory findings (particularly urine analysis), and electrocardiography. The age of the children with CM was below 12 years old, and the girl-to-boy ratio was 7:1. Mucus in urine was positive in 357 (99.44%) children in Group A and 22 (8.3%) in Group B (P<0.001). A significant correlation was found between the presence of mucus in urine and masturbatory behaviors (P<0.001). Our findings suggest that the presence of mucus in urine can be used as an alternative laboratory test in children with CM below 12 years old and even in infants (≤24 months old). Further studies are needed to confirm the results.

  7. Sample handling for mass spectrometric proteomic investigations of human urine.

    PubMed

    Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid

    2008-09-01

    Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study

    PubMed Central

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A.; Chauhan, Sunanda

    2018-01-01

    Background: Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. Materials and Methods: We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. Results: We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Conclusions: Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material. PMID:29643653

  9. What is the best method to evaluate urine pH? A trial of three urinary pH measurement methods in a stone clinic.

    PubMed

    Ilyas, Rebecca; Chow, Karyee; Young, J Graham

    2015-01-01

    Monitoring of urinary pH is an important part of the assessment of patients with urinary tract stones. It provides valuable information about the future stone risk of certain patients and further allows the effective tailoring of medical intervention. Accurate measurement is therefore essential in these patients. The purpose of this study was to determine the most accurate method of measuring urinary pH in an outpatient setting. Materials, Methods, and Participants: Urine samples were collected from 200 patients attending stone clinics at The University Hospital of South Manchester. pH was measured by three commonly used methods: Siemens Clinitek Status pH meter, a hand-held pH meter, and litmus paper read visually. Results were compared with readings simultaneously obtained from a bench-top laboratory pH machine, which is the reference method for pH measurement. The pH readings obtained were analyzed using the Bland-Altman plot. When compared with the reference method, the hand-held pH meter differed the least with a mean bias of 0.0073 and a maximum under-read of -0.2 pH units and maximum over-read of +0.2 pH units. The Siemens Clinitek pH meter differed most with a mean bias of -0.108, with a maximum over-read of +0.99 pH units and a maximum under-read of 0.78 pH units. The pH values obtained with the litmus paper gave similar results to that of the Clinitek pH meter with a mean bias of -0.069, with a maximum over-read of 0.96 and maximum under-read of 0.82 pH units. The hand-held pH device gave urinary pH readings that most closely and consistently matched those of the reference bench-top laboratory machine. This method of pH measurement should be considered in stone clinics in patients with pH-dependent stone risk.

  10. Advances in the Diagnosis of Human Opisthorchiasis: Development of Opisthorchis viverrini Antigen Detection in Urine

    PubMed Central

    Duenngai, Kunyarat; Wangboon, Chompunoot; Sithithaworn, Jiraporn; Watwiengkam, Nattaya; Namwat, Nisana; Techasen, Anchalee; Loilome, Watcharin; Yongvanit, Puangrat; Loukas, Alex; Sithithaworn, Paiboon; Bethony, Jeffrey M.

    2015-01-01

    Background Many strategies to control opisthorchiasis have been employed in Thailand, but not in the other neighbouring countries. Specific control methods include mass drug administration (MDA) and health education to reduce raw fish consumption. These control efforts have greatly shifted the epidemiology of Opisthorchis viverrini (OV) infection over the last decade from presenting as densely concentrated "heavy" infections in single villages to widespread "light" OV infections distributed over wide geographical areas. Currently, the "gold standard" detection method for OV infection is formalin ethyl-acetate concentration technique (FECT), which has limited diagnostic sensitivity and diagnostic specificity for light OV infections, with OV eggs often confused with eggs of minute intestinal flukes (MIFs) in feces. In this study, we developed and evaluated the diagnostic performance of a monoclonal antibody-based enzyme-linked immunosorbent assay for the measurement of OV excretory-secretory (ES) antigens in urine (urine OV-ES assay) for the diagnosis of opisthorchiasis compared to the gold standard detection FECT method. Methodology We tested several methods for pre-treating urine samples prior to testing the diagnostic performance of the urine OV-ES assay. Using trichloroacetic acid (TCA) pre-treated urine, we compared detection and quantification of OV infection using the urine OV-ES assay versus FECT in OV-endemic areas in Northeastern Thailand. Receiver operating characteristic (ROC) curves were used to determine the diagnostic sensitivity and specificity of the urine OV-ES assay using TCA pre-treated urine, and to establish diagnostic positivity thresholds. The Positive Predictive Value as well as the likelihood of obtaining a positive test result (LR+) or a negative test result (LR-) were calculated for the established diagnostic positivity threshold. Diagnostic risks (Odds Ratios) were estimated using logistic regression. Results When urine samples were pre-treated with TCA prior to use in the urine OV-ES assay, the analytical sensitivity was significantly improved. Using TCA pre-treatment of urine, the urine OV-ES assay had a limit of detection (LoD) of 39 ng/ml compared to the LoD of 52 ng/mL reported for coprological antigen detection methods. Similarly, the urine OV-ES assay correlated significantly with intensity of OV infection as measured by FECT. The urine OV-ES assay was also able to detect 28 individuals as positive from the 63 (44.4%) individuals previously determined to be negative using FECT. The likelihood of a positive diagnosis of OV infection by urine OV-ES assay increased significantly with the intensity of OV infection as determined by FECT. With reference to FECT, the sensitivity and specificity of the urine OV-ES assay was 81% and 70%, respectively. Conclusion The detection of OV-infection by the urine OV-ES assay showed much greater diagnostic sensitivity and diagnostic specificity than the current "gold standard" FECT method for the detection and quantification of OV infection. Due to its ease-of-use, and noninvasive sample collection (urine), the urine OV-ES assay offers the potential to revolutionize the diagnosis of liver fluke infection and provide an effective tool for control and elimination of these tumorigenic parasites. PMID:26485024

  11. Uncommon Human Urinary Tract Myiasis Due to Psychoda Sp. Larvae, Kashan, Iran: A Case Report.

    PubMed

    Rasti, Sima; Dehghani, Rouhullah; Khaledi, Hassan Naeimi; Takhtfiroozeh, Sayed Mahdi; Chimehi, Elahe

    2016-01-01

    Contamination of human and animal body tissues with flies' larvae and diptera cause myiasis. A 26 yr old female patient refers to Kashan Shahid Beheshti Hospital, central Iran because of urogenital infection, pain in the right part of stomach, smelly and reddish vaginal discharge and frequent urination. In the first checking, urine sample was taken. In the sample, active and alive larvae were seen. The live samples were taken to the Environmental Health Department Lab of Kashan University of Medical Sciences in clean glass jars. In the morphological survey, Psychoda sp larvae were identified. In Iran, this study is the first report of this species of larva that causes urinary myiasis. This fly larva is not carnivore or bloodsucker and feeds on bacterial agents. Observance of personal hygiene especially during defecation and urination is essential to prevent contamination of this type of myiasis.

  12. Asymptomatic bacteriuria in pregnant women attending Boo-Ali Hospital Tehran Iran: Urine analysis vs. urine culture

    PubMed Central

    Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana

    2017-01-01

    Background Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. Objective The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. Methods A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Results Of 123 urine samples, significant asymptomatic bacteriuria (≥104 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Conclusion Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and specificity of 100%, whereas we can only refer the pregnant women with positive leucocyte esterase test and significant pyuria to the urine culture. PMID:29403616

  13. Usability application of multiplex polymerase chain reaction in the diagnosis of microorganisms isolated from urine of patients treated in cancer hospital

    PubMed Central

    Cybulski, Zefiryn; Schmidt, Katarzyna; Grabiec, Alicja; Talaga, Zofia; Bociąg, Piotr; Wojciechowicz, Jacek; Roszak, Andrzej; Kycler, Witold

    2013-01-01

    Background The objective of this study was: i) to compare the results of urine culture with polymerase chain reaction (PCR) -based detection of microorganisms using two commercially available kits, ii) to assess antimicrobial susceptibility of urine isolates from cancer patients to chosen antimicrobial drugs and, if necessary, to update the recommendation of empirical therapy. Materials and methods. A one-year hospital-based prospective study has been conducted in Greater Poland Cancer Centre and Genetic Medicine Laboratory CBDNA Research Centre in 2011. Urine cultures and urine PCR assay from 72 patients were examined Results Urine cultures and urine PCR assay from 72 patients were examined. Urine samples were positive for 128 strains from which 95 (74%) were identical in both tests. The most frequently isolated bacteria in both culture and PCR assay were coliform organisms and Enterococcus spp. The Gram negative bacilli were most resistant to cotrimoxazol. 77.2% of these bacilli and 100% of E. faecalis and S. agalactiae were sensitive to amoxicillin-clavulanic acid. 4.7% of Gram positive cocci were resistant to nitrofurantoin. Conclusions The PCR method quickly finds the causative agent of urinary tract infection (UTI) and, therefore, it can help with making the choice of the proper antimicrobial therapy at an early stage. It appears to be a viable alternative to the recommendations made in general treatment guidelines, in cases where diversified sensitivity patterns of microorganisms have been found. PMID:24133395

  14. Detection of Cytomegalovirus (CMV) Infection in Wheezing Infants by Urine DNA and Serum IgG Testing.

    PubMed

    Zeng, Zhao-Cheng; Chang, Qing; Sun, Zhi-Wei; Song, Ming-Mei; Jin, Xin-Ling; Jiang, Shu-Ya; Yang, Xia

    2017-03-11

    BACKGROUND The aim of this study was to investigate the involvement of CMV infection in wheezing infants and the association between CMV-DNA and immunoglobulins (Igs). MATERIAL AND METHODS A total of 243 wheezing infants and 3,000 parturients were enrolled in this study. The infants were randomly grouped to receive blood HCMV-DNA tests (n=46) or urine HCMV-DNA tests (n=197). Furthermore, all participants had serum CMV-specific IgM and IgG testing. Afterwards, 10 HCMV-IgG positive infants were randomly selected for simultaneous blood and urine HCMV-DNA tests, and 25 HCMV-IgG positive puerperants were randomly selected for urine HCMV-DNA tests. RESULTS The detection rate of urine HCMV-DNA was significantly higher than that of blood HCMV-DNA (67.5% vs. 13.0%, p<0.001). Fifteen (6.2%) and 190 (80.0%) infants showed positive CMV-specific IgM and IgG results (p<0.001), respectively. Among the 10 HCMV-IgG positive infants tested further, only two infants had positive HCMV-DNA blood tests, while all of the 10 infants had positive HCMV-DNA urine tests. However, HCMV-DNA was not detected in the urine of the 25 randomly selected parturients positive for HCMV-IgG. CONCLUSIONS CMV infection may be one of the causes of wheezing in infants; CMV infection can be detected by urine-HCMV-DNA and serum HCMV-IgG testing. Infants were more susceptible to CMV infection than parturients.

  15. Measurement of glomerular filtration rate in the conscious rat.

    PubMed

    Pestel, Sabine; Krzykalla, Volker; Weckesser, Gerhard

    2007-01-01

    Glomerular filtration rate (GFR) is an important parameter for studying drug-induced impairments on renal function in rats. The GFR is calculated from the concentration of creatinine and blood urea nitrogen (BUN) in serum and in urine, respectively. Following current protocols serum and urine samples must be taken from the same animal. Thus, in order to determine time-dependent effects it is necessary to use for each time point one separated group of animals. We developed a statistical test which allows analyzing the GFR from two different groups of animals: one used for repeated serum and the other one used for repeated urine analysis. Serum and urine samples were taken from two different sets of rats which were otherwise treated identically, i.e. drug doses, routes of administration (per os or per inhalation) and tap water loading. For each dose group GFR mean, standard deviation and statistical analysis to identify differences between the dose groups were determined. After determination of the optimal time points for measurements, the effect on GFR of the three reference compounds, furosemide, hydrochlorothiazide and formoterol, was calculated. The results showed that the diuretic drugs furosemide and hydrochlorothiazide decreased the GFR and the antidiuretic drug formoterol increased the GFR, as counter regulation on urine loss or urine retention, respectively. A mathematical model and the corresponding algorithm were developed, which can be used to calculate the GFR, and to test for differences between groups from two separated sets of rats, one used for urine, and the other one for serum analysis. This new method has the potential to reduce the number of animals needed and to improve the quality of data generated from various groups of animals in renal function studies.

  16. Development and validation of a highly sensitive urine-based test to identify patients with colonic adenomatous polyps.

    PubMed

    Wang, Haili; Tso, Victor; Wong, Clarence; Sadowski, Dan; Fedorak, Richard N

    2014-03-20

    Adenomatous polyps are precursors of colorectal cancer; their detection and removal is the goal of colon cancer screening programs. However, fecal-based methods identify patients with adenomatous polyps with low levels of sensitivity. The aim or this study was to develop a highly accurate, prototypic, proof-of-concept, spot urine-based diagnostic test using metabolomic technology to distinguish persons with adenomatous polyps from those without polyps. Prospective urine and stool samples were collected from 876 participants undergoing colonoscopy examination in a colon cancer screening program, from April 2008 to October 2009 at the University of Alberta. Colonoscopy reference standard identified 633 participants with no colonic polyps and 243 with colonic adenomatous polyps. One-dimensional nuclear magnetic resonance spectra of urine metabolites were analyzed to define a diagnostic metabolomic profile for colonic adenomas. A urine metabolomic diagnostic test for colonic adenomatous polyps was established using 67% of the samples (un-blinded training set) and validated using the other 33% of the samples (blinded testing set). The urine metabolomic diagnostic test's specificity and sensitivity were compared with those of fecal-based tests. Using a two-component, orthogonal, partial least-squares model of the metabolomic profile, the un-blinded training set identified patients with colonic adenomatous polyps with 88.9% sensitivity and 50.2% specificity. Validation using the blinded testing set confirmed sensitivity and specificity values of 82.7% and 51.2%, respectively. Sensitivities of fecal-based tests to identify colonic adenomas ranged from 2.5 to 11.9%. We describe a proof-of-concept spot urine-based metabolomic diagnostic test that identifies patients with colonic adenomatous polyps with a greater level of sensitivity (83%) than fecal-based tests.

  17. Clinicians' interpretations of point of care urine culture versus laboratory culture results: analysis from the four-country POETIC trial of diagnosis of uncomplicated urinary tract infection in primary care.

    PubMed

    Hullegie, Saskia; Wootton, Mandy; Verheij, Theo J M; Thomas-Jones, Emma; Bates, Janine; Hood, Kerenza; Gal, Micaela; Francis, Nick A; Little, Paul; Moore, Michael; Llor, Carl; Pickles, Timothy; Gillespie, David; Kirby, Nigel; Brugman, Curt; Butler, Christopher C

    2017-08-01

    Urine culture at the point of care minimises delay between obtaining the sample and agar inoculation in a microbiology laboratory, and quantification and sensitivity results can be available more rapidly in primary care. To identify the degree to which clinicians' interpretations of a point-of-care-test (POCT) urine culture (Flexicult™ SSI-Urinary Kit) agrees with laboratory culture in women presenting to primary care with symptoms of uncomplicated urinary tract infections (UTI). Primary care clinicians used the Flexicult™-POCT, recorded their findings and took a photograph of the result, which was interpreted by microbiology laboratory technicians. Urine samples were additionally processed in routine care laboratories. Cross tabulations were used to identify important differences in organism identification, quantification and antibiotic susceptibility between these three sources of data. The influence of various laboratory definitions for UTI on culture were assessed. Primary care clinicians identified 202/289 urine samples (69.9%) as positive for UTI using the Flexicult™-POCT, whereas laboratory culture identified 94-190 (32.5-65.7%) as positive, depending on definition thresholds. 82.9% of samples identified positive for E. coli on laboratory culture were also considered positive for E. coli using the Flexicult™ -POCT, and susceptibilities were reasonably concordant. There were major discrepancies between laboratory staff interpretation of Flexicult™ photographs, clinicians' interpretation of the Flexicult™ test, and laboratory culture results. Flexicult™-POCT overestimated the positivity rate of urine samples for UTI when laboratory culture was used as the reference standard. However, it is unclear whether point-of-care or laboratory based urine culture provides the most valid diagnostic information. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Guanidinoacetate and creatine plus creatinine assessment in physiologic fluids: an effective diagnostic tool for the biochemical diagnosis of arginine:glycine amidinotransferase and guanidinoacetate methyltransferase deficiencies.

    PubMed

    Carducci, Claudia; Birarelli, Maurizio; Leuzzi, Vincenzo; Carducci, Carla; Battini, Roberta; Cioni, Giovanni; Antonozzi, Italo

    2002-10-01

    Disorders of creatine metabolism arise from genetic alterations of arginine:glycine amidinotransferase (AGAT), guanidinoacetate methyltransferase (GAMT), and the creatine transporter. We developed a strategy for the detection of AGAT and GAMT defects by measurement of guanidinoacetate (GAA) and creatine plus creatinine (Cr+Crn) in biological fluids. Three patients with AGAT deficiency from the same pedigree and their eight relatives, as well as a patient affected by a GAMT defect and his parents were analyzed by a new HPLC procedure in comparison with 90 controls. The method, which uses precolumn derivatization with benzoin, separation with a reversed-phase column, and fluorescence detection, has shown good precision and sensitivity and requires minimal sample handling. In the three AGAT patients, plasma GAA was 0.01-0.04 micro mol/L [mean (SD) for neurologically normal controls was 1.16 (0.59) micromol/L], Cr+Crn was 15-29 micro mol/L [reference limit in our laboratory, 79 (38) micromol/L]. Urinary GAA was 2.4-5.8 micro mol/L [reference, 311 (191) micromol/L], and Cr+Crn was 2.1-3.3 mmol/L [reference, 9.9 (4.1) mmol/L]. We found a smaller decrease in GAA and Cr+Crn in some carriers of an AGAT defect. In the patient with GAMT deficiency, plasma and urine GAA was increased (18.6 and 1783 micromol/L, respectively), and Cr+Crn was decreased in plasma (10.7 micromol/L) and urine (2.1 mmol/L). GAA was increased in the parents' plasmas and in the mother's urine. The assessment of GAA is a new tool for the detection of both GAMT and AGAT deficiencies.

  19. Monitoring dehydroepiandrosterone (DHEA) in the urine of Thoroughbred geldings for doping control purposes.

    PubMed

    Viljanto, Marjaana; Hincks, Pamela; Hillyer, Lynn; Cawley, Adam; Suann, Craig; Noble, Glenys; Walker, Christopher J; Parkin, Mark C; Kicman, Andrew T; Scarth, James

    2018-05-24

    The use of testosterone and its pro-drugs, such as DHEA, is currently regulated in horseracing by the application of international testosterone thresholds. However, additional steroidomic approaches, such as steroid ratios, to distinguish overall adrenal stimulation from drug administrations and an equine biological passport for longitudinal steroid profiling of individual animals could be advantageous in equine doping testing. Thus, DHEA concentrations and related ratios (testosterone (T) to DHEA and DHEA to epitestosterone (E)) were assessed in the reference population by quantitative analysis of 200 post-race gelding urine samples using liquid chromatography tandem mass spectrometry. DHEA concentrations ranged between 0.9 and 136.6 ng/mL (mean 12.8 ng/mL), T:DHEA ratios between 0.06 and 1.85 (mean 0.43) and DHEA:E ratios between 0.21 and 13.56 (mean 2.20). Based on the reference population statistical upper limits of 5.4 for T:DHEA ratio and 48.1 for DHEA:E ratio are proposed with a risk of 1 in 10,000 for a normal outlier exceeding the value. Analysis of post-administration urine samples collected following administrations of DHEA, EquiBolic&® (a mix of DHEA and pregnenolone) and testosterone propionate to geldings showed that the upper limit for T:DHEA ratio was exceeded following testosterone propionate administration and DHEA:E ratio following DHEA administrations and thus these ratios could be used as additional biomarkers when determining the cause of an atypical testosterone concentration. Additionally, DHEA concentrations and ratios can be used as a starting point to establish reference ranges for an equine biological passport. This article is protected by copyright. All rights reserved.

  20. Acute suppression of serum IgM and IgA in tank workers exposed to benzene.

    PubMed

    Kirkeleit, J; Ulvestad, E; Riise, T; Bråtveit, M; Moen, B E

    2006-12-01

    We investigated associations between benzene exposure and alterations of proteins and cells of the immune system among workers maintaining cargo tanks containing crude oil residues. Individual exposure to benzene, benzene in blood and urine, peripheral blood lymphocytes (total lymphocytes, lymphocytes in subpopulations CD3, CD4, CD8, CD19, CD56 and CD4/CD8 ratio), complement factors C3 and C4 and serum concentration of immunoglobulins (IgG, IgA, IgM and IgE) were analysed among 13 tank workers and nine unexposed referents (catering section). Benzene exposure was measured during three consecutive 12-h work days. Blood and urine samples were collected pre-shift on the first day (baseline), post-shift on the third day, and pre-next shift on the following morning. The time spent in the cargo tank was logged. The individual geometric mean benzene exposure in the breathing zone of tank workers over 3 days was 0.15 p.p.m. (range 0.01-0.62 p.p.m.) (n = 26). The geometric mean benzene concentration in blood post-shift was 12.3 nmol/l among tank workers versus 0.7 nmol/l among the referents. Tank workers showed a decline (versus referents) in IgM from baseline to post-shift (t-test, P = 0.04) and IgA from baseline to pre-next shift (t-test, P = 0.01). They also showed a decline in CD4 T cells from baseline to post-shift (t-test, P = 0.04). Suppression correlated with benzene exposure, benzene concentrations in blood and urine and time spent in the tank. The groups did not differ significantly in the change in other immune parameters. The clinical significance is unknown and warrants further studies.

  1. Rapid methods for the isolation of actinides Sr, Tc and Po from raw urine.

    PubMed

    McAlister, Daniel R; Horwitz, E Philip; Harvey, James T

    2011-08-01

    Rapid methods for the isolation and analysis of individual actinides (Th, U, Pu, Am/Cm) and Sr, Tc and Po from small volumes of raw urine have been developed. The methods involve acidification of the sample and the addition of aluminum nitrate or aluminum chloride salting-out agent prior to isolation of the desired analyte using a tandem combination of prefilter material and extraction chromatographic resin. The method has been applied to the separation of individual analytes from spiked urine samples. Analytes were recovered in high yield and radionuclide purity with separation times as low as 30 min. The chemistry employed is compatible with automation on the ARSIIe instrument.

  2. Nonhazardous Urine Pretreatment Method

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Holtsnider, John T.

    2012-01-01

    A method combines solid phase acidification with two non-toxic biocides to prevent ammonia volatilization and microbial proliferation. The safe, non-oxidizing biocide combination consists of a quaternary amine and a food preservative. This combination has exhibited excellent stabilization of both acidified and unacidified urine. During pretreatment tests, composite urine collected from donors was challenged with a microorganism known to proliferate in urine, and then was processed using the nonhazardous urine pre-treatment method. The challenge microorganisms included Escherichia coli, a common gram-negative bacteria; Enterococcus faecalis, a ureolytic gram-positive bacteria; Candida albicans, a yeast commonly found in urine; and Aspergillus niger, a problematic mold that resists urine pre-treatment. Urine processed in this manner remained microbially stable for over 57 days. Such effective urine stabilization was achieved using non-toxic, non-oxidizing biocides at higher pH (3.6 to 5.8) than previous methods in use or projected for use aboard the International Space Station (ISS). ISS urine pretreatment methods employ strong oxidants including ozone and hexavalent chromium (Cr(VI)), a carcinogenic material, under very acidic conditions (pH = 1.8 to 2.4). The method described here offers a much more benign chemical environment than previous pretreatment methods, and will lower equivalent system mass (ESM) by reducing containment volume and mass, system complexity, and crew time needed to handle pre-treatment chemicals. The biocides, being non-oxidizing, minimize the potential for chemical reactions with urine constituents to produce volatile, airborne contaminants such as cyanogen chloride. Additionally, the biocides are active under significantly less acidic conditions than those used in the current system, thereby reducing the degree of required acidification. A simple flow-through solid phase acidification (SPA) bed is employed to overcome the natural buffering capacity of urine, and to lower the pH to levels that fix ammoniacal nitrogen in the non-volatile and highly water soluble NH4 + form. Citric acid, a highly soluble, solid tricarboxylic acid essential to cellular metabolism, and typically used as a food preservative, has also been shown to efficiently acidify urine in conjunction with non-oxidizing biocides to provide effective stabilization with respect to both microbial growth and ammonia volatilization.

  3. Comparison of the Automated cobas u 701 Urine Microscopy and UF-1000i Flow Cytometry Systems and Manual Microscopy in the Examination of Urine Sediments.

    PubMed

    Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee

    2016-09-01

    The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.

  4. Small bowel injury after suprapubic catheter insertion presenting 3 years after initial insertion

    PubMed Central

    Gallagher, Kevin M; Good, Daniel W; Brush, John P; Al-hasso, Ammar; Stewart, Grant D

    2013-01-01

    A 77-year-old woman was referred to urology with blockages of her suprapubic catheter (SPC). The catheter was replaced easily in the emergency department, however, no urine was draining, only a cloudy green fluid was visible. On cystoscopy bilious material was identified in the bladder. There was no catheter visible. There seemed to be a fistulous tract entering the bladder at the left dome. The urethra was dilated, a urethral catheter was placed and the SPC was removed. A CT demonstrated that the SPC tract transfixed a loop of pelvic small bowel and entered the bladder with no intraperitoneal contrast leak. The patient recovered well and did not require laparotomy. This case emphasises that bowel perforation, although rare, must be considered as a complication of SPC placement even years after initial insertion when catheter problems arise. Unusually, we learn that this complication may not present with abdominal pain or peritonism. PMID:24326435

  5. A new rapid diagnostic test for detection of anti-Schistosoma mansoni and anti-Schistosoma haematobium antibodies

    PubMed Central

    2013-01-01

    Background Parasitological methods are widely used for the diagnosis of schistosomiasis. However, they are insensitive, particularly in areas of low endemicity, and labour-intensive. Immunoassays based on detection of anti-schistosome antibodies have the merit of high sensitivity and recently a rapid diagnostic test (RDT), incorporating Schistosoma mansoni cercarial transformation fluid (SmCTF) for detection of anti-schistosome antibodies in blood has been developed. Here, we assessed the diagnostic performance of the SmCTF-RDT for S. mansoni and S. haematobium infections by comparing it with microscopy for egg detection. Methods A cross-sectional survey was carried out in Azaguié, south Côte d’Ivoire. 118 pre-school-aged children submitted two stool and two urine samples, which were subjected to the Kato-Katz and urine filtration methods for the detection of S. mansoni and S. haematobium eggs, respectively. Urine was also subjected to a commercially available cassette test for S. mansoni, which detects circulating cathodic antigen. A finger-prick blood sample was used for the SmCTF-RDT for detection of anti-S. mansoni and anti-S. haematobium antibodies. Results The prevalence of both anti-S. mansoni and anti-S. haematobium antibodies was more than three times higher than the prevalence of infection estimated by egg detection under a microscope. Using quadruplicate Kato-Katz as the reference standard for the diagnosis of S. mansoni infection, the sensitivity, negative predictive value (NPV), and positive predictive value (PPV) of the SmCTF-RDT was 75.0%, 84.2% and 22.5%, respectively. When two urine filtrations were considered as the reference standard for the diagnosis of S. haematobium infection, the sensitivity, NPV and PPV of SmCTF-RDT was 66.7%, 94.9% and 5.1%, respectively. The specificity of SmCTF-RDT, when using egg-detection as the reference standard, was estimated to be 34.4%. This low specificity may be a reflection of the relative insensitivity of the direct diagnostic approaches using microscopy. Conclusions The SmCTF-RDT is at least as sensitive as duplicate Kato-Katz and a single urine filtration for detection of S. mansoni and S. haematobium, respectively. Further investigations into the specificity of the test for anti-schistosome antibodies are necessary, but our results suggest that it may be a useful tool for mapping the prevalence of anti-schistosome antibodies in a given population pending intervention. PMID:23360734

  6. Tentative reference values for environmental pollutants in blood or urine from the children of Kinshasa.

    PubMed

    Tuakuila, J; Kabamba, M; Mata, H; Mbuyi, F

    2015-11-01

    The DRC, as most of African nations, does not have a national biomonitoring programme and there is a lack of information on background levels of environmental pollutants in the general DRC population, particularly in children. The focus of the data presented in this report aims to establish the background levels of a range of environmental pollutants in urine or blood from the children population of Kinshasa. Based on the representative data collection of the Kinshasa population, the survey selected 125 children aged 1-14years and living in Kinshasa (6years on average, 56% of girls, 100% of non-smokers, without amalgam fillings and consumers of fish 3 times per week). Biomarkers of a range of metals (As, Cd, Hg and Pb), pyrene (PAH) and benzene were analyzed in the blood or urine samples. Globally, the results indicate that the exposure levels of children living in Kinshasa are 10 times higher than those published by the American, Canadian and German children surveys. This study provides the first Reference Values of environmental pollutants [As, Cd, Hg, Pb, pyrene (PAH) and benzene] in the Kinshasa children population and reveals elevated levels of all biomarkers studied. The data set of this study may allow environmental and health authorities of DRC to undertake a national biomonitoring programme, especially with four insights for the protection of human heath. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Antimony exposure and speciation in human biomarkers near an active mining area in Hunan, China.

    PubMed

    Ye, Li; Qiu, Shixin; Li, Xinhai; Jiang, Yuxuan; Jing, Chuanyong

    2018-05-28

    Antimony (Sb) exposure threatens human health. To identify human biomarkers for Sb exposure, we analyzed 480 environmental samples from an active Sb mining area in Hunan, China. Elevated Sb concentrations exceeding the reference level were detected in drinking water (70% of n = 83 total samples), foods (80%, n = 188), urine (95%, n = 63), saliva (44%, n = 48), hair (80%, n = 51) and nails (83%, n = 47). Drinking water contributed 85%-100% of the average daily dose (ADD) of Sb, and the total ADD (11.7 μg/kg bodyweight/day) was up to thirty times higher than the oral reference dose (0.4 μg/kg bodyweight/day) as recommended by USEPA. A positive correlation was found between ADD and Sb content in hair (p = 0.02), but not in urine (p = 0.051), saliva (p = 0.52) or nails (p = 0.85), suggesting that hair is the best non-invasive biomarker. Micro X-ray fluorescence analysis indicated that Sb is distributed in discrete spots in hair and nails, and Sb distribution is correlated with other metals. Methylated Sb species were predominant in urine (46%-100%) and saliva (74%-100%) in collected samples, implying that the human metabolic system adopts methylation as an effective pathway to detoxify and excrete Sb. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Electrolytic pretreatment unit gaseous effluent conditioning

    NASA Technical Reports Server (NTRS)

    Colombo, G. V.; Putnam, D. F.

    1976-01-01

    The electrolytic pretreatment of urine is an advanced process that eliminates the need for handling and storing the highly corrosive chemicals that are normally used in water reclamation systems. The electrolytic pretreatment process also converts the organic materials in urine to gases (N2 and O2) that can be used to replenish those lost to space by leakage, venting, and air lock operations. The electrolytic process is more than a pretreatment, since it decreases the urine solids content by approximately one third, thus reducing the load and eventual solids storage requirements of the urine processing system. The evolved gases from the pretreatment step cannot, however, be returned directly to the atmosphere of a spacecraft without first removing several impurities including hydrogen, chlorine, and certain organic compounds. A treatment concept was developed that would decrease the impurities in the gas stream that emanates from an electrolysis unit to levels sufficiently low to allow the conditioned gas stream to be safely discharged to a spacecraft atmosphere. Two methods were experimentally demonstrated that can accomplish the desired cleanup. The bases of the two methods are, repectively: (1) raw urine scrubbing and (2) silica gel sorption.

  9. Quantitative analysis of urea in human urine and serum by 1H nuclear magnetic resonance†

    PubMed Central

    Liu, Lingyan; Mo, Huaping; Wei, Siwei

    2016-01-01

    A convenient and fast method for quantifying urea in biofluids is demonstrated using NMR analysis and the solvent water signal as a concentration reference. The urea concentration can be accurately determined with errors less than 3% between 1 mM and 50 mM, and less than 2% above 50 mM in urine and serum. The method is promising for various applications with advantages of simplicity, high accuracy, and fast non-destructive detection. With an ability to measure other metabolites simultaneously, this NMR method is also likely to find applications in metabolic profiling and system biology. PMID:22179722

  10. 40 CFR 160.195 - Retention of records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., terminated, or discontinued. (c) Wet specimens, samples of test, control, or reference substances, and... storage, shall be retained only as long as the quality of the preparation affords evaluation. Specimens obtained from mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine...

  11. Power of Orbitrap-based LC-high resolution-MS/MS for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MSn or GC-MS procedures.

    PubMed

    Michely, Julian A; Meyer, Markus R; Maurer, Hans H

    2018-01-01

    Reliable, sensitive, and comprehensive urine screening procedures by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS) with low or high resolution (HR) are of high importance for drug testing, adherence monitoring, or detection of toxic compounds. Besides conventional urine sampling, dried urine spots are of increasing interest. In the present study, the power of LC-HR-MS/MS was investigated for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MS n or GC-MS procedures. Authentic human urine samples (n = 103) were split in 4 parts. One aliquot was prepared by precipitation (UP), one by UP with conjugate cleavage (UglucP), one spot on filter paper cards and prepared by on-spot cleavage followed by liquid extraction (DUSglucE), and one worked-up by acid hydrolysis, liquid-liquid extraction, and acetylation for GC-MS analysis. The 3 series of LC-HR-MS/MS results were compared among themselves, to corresponding published LC-MS n data, and to screening results obtained by conventional GC-MS. The reference libraries used for the 3 techniques contained over 4500 spectra of parent compounds and their metabolites. The number of all detected hits (770 drug intakes) was set to 100%. The LC-HR-MS/MS approach detected 80% of the hits after UP, 89% after UglucP, and 77% after DUSglucE, which meant over one-third more hits in comparison to the corresponding published LC-MS n results with ≤49% detected hits. The GC-MS approach identified 56% of all detected hits. In conclusion, LC-HR-MS/MS provided the best screening results after conjugate cleavage and precipitation. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Direct Detection and Identification of Bacterial Pathogens from Urine with Optimized Specimen Processing and Enhanced Testing Algorithm

    PubMed Central

    Huang, Bin; Zhang, Lei; Zhang, Weizheng; Liao, Kang; Zhang, Shihong; Zhang, Zhiquan; Ma, Xingyan; Chen, Jialong; Zhang, Xiuhong; Qu, Pinghua; Wu, Shangwei

    2017-01-01

    ABSTRACT Rapid and accurate detection and identification of microbial pathogens causing urinary tract infections allow prompt and specific treatment. We optimized specimen processing to maximize the limit of detection (LOD) by matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) and evaluated the capacity of combination of MALDI-TOF MS and urine analysis (UA) for direct detection and identification of bacterial pathogens from urine samples. The optimal volumes of processed urine, formic acid/acetonitrile, and supernatant spotted onto the target plate were 15 ml, 3 μl, and 3 μl, respectively, yielding a LOD of 1.0 × 105 CFU/ml. Among a total of 1,167 urine specimens collected from three hospital centers, 612 (52.4%) and 351 (30.1%) were, respectively, positive by UA and urine culture. Compared with a reference method comprised of urine culture and 16S rRNA gene sequencing, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MALDI-TOF MS alone and MALDI-TOF MS coupled with UA were 86.6% versus 93.4% (χ2 = 8.93; P < 0.01), 91.5% versus 96.3% (χ2 = 7.06; P < 0.01), 81.5% versus 96.4% (χ2 = 37.32; P < 0.01), and 94.1% versus 93.1% (χ2 = 0.40; P > 0.05), respectively. No significant performance differences were revealed among the three sites, while specificity and NPV of MALDI-TOF MS for males were significantly higher than those for females (specificity, 94.3% versus 77.3%, χ2 = 44.90, P < 0.01; NPV, 95.5% versus 86.1%, χ2 = 18.85, P < 0.01). Our results indicated that the optimization of specimen processing significantly enhanced analytical sensitivity and that the combination of UA and MALDI-TOF MS provided an accurate and rapid detection and identification of bacterial pathogens directly from urine. PMID:28249997

  13. Direct Detection and Identification of Bacterial Pathogens from Urine with Optimized Specimen Processing and Enhanced Testing Algorithm.

    PubMed

    Huang, Bin; Zhang, Lei; Zhang, Weizheng; Liao, Kang; Zhang, Shihong; Zhang, Zhiquan; Ma, Xingyan; Chen, Jialong; Zhang, Xiuhong; Qu, Pinghua; Wu, Shangwei; Chen, Cha; Tang, Yi-Wei

    2017-05-01

    Rapid and accurate detection and identification of microbial pathogens causing urinary tract infections allow prompt and specific treatment. We optimized specimen processing to maximize the limit of detection (LOD) by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and evaluated the capacity of combination of MALDI-TOF MS and urine analysis (UA) for direct detection and identification of bacterial pathogens from urine samples. The optimal volumes of processed urine, formic acid/acetonitrile, and supernatant spotted onto the target plate were 15 ml, 3 μl, and 3 μl, respectively, yielding a LOD of 1.0 × 10 5 CFU/ml. Among a total of 1,167 urine specimens collected from three hospital centers, 612 (52.4%) and 351 (30.1%) were, respectively, positive by UA and urine culture. Compared with a reference method comprised of urine culture and 16S rRNA gene sequencing, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MALDI-TOF MS alone and MALDI-TOF MS coupled with UA were 86.6% versus 93.4% (χ 2 = 8.93; P < 0.01), 91.5% versus 96.3% (χ 2 = 7.06; P < 0.01), 81.5% versus 96.4% (χ 2 = 37.32; P < 0.01), and 94.1% versus 93.1% (χ 2 = 0.40; P > 0.05), respectively. No significant performance differences were revealed among the three sites, while specificity and NPV of MALDI-TOF MS for males were significantly higher than those for females (specificity, 94.3% versus 77.3%, χ 2 = 44.90, P < 0.01; NPV, 95.5% versus 86.1%, χ 2 = 18.85, P < 0.01). Our results indicated that the optimization of specimen processing significantly enhanced analytical sensitivity and that the combination of UA and MALDI-TOF MS provided an accurate and rapid detection and identification of bacterial pathogens directly from urine. Copyright © 2017 American Society for Microbiology.

  14. A Versatile Nanowire Platform for Highly Efficient Isolation and Direct PCR-free Colorimetric Detection of Human Papillomavirus DNA from Unprocessed Urine

    PubMed Central

    Lee, HyungJae; Choi, Mihye; Hwang, Sang-Hyun; Cho, Youngnam

    2018-01-01

    Purpose: As human papillomavirus (HPV) is primarily responsible for the development of cervical cancer, significant efforts have been devoted to develop novel strategies for detecting and identifying HPV DNA in urine. The analysis of target DNA sequences in urine offers a potential alternative to conventional methods as a non-invasive clinical screening and diagnostic assessment tool for the detection of HPV. However, the lack of efficient approaches to isolate and directly detect HPV DNA in urine has restricted its potential clinical use. In this study, we demonstrated a novel approach of using polyethylenimine-conjugated magnetic polypyrrole nanowires (PEI-mPpy NWs) for the extraction, identification, and PCR-free colorimetric detection of high-risk strains of HPV DNA sequences, particularly HPV-16 and HPV-18, in urine specimens of cervical cancer patients. Materials and Methods: We fabricated and characterized polyethylenimine-conjugated magnetic nanowires (PEI/mPpy NWs). PEI/mPpy NWs-based HPV DNA isolation and detection strategy appears to be a cost-effective and practical technology with greater sensitivity and accuracy than other urine-based methods. Results: The analytical and clinical performance of PEI-mPpy NWs was evaluated and compared with those of cervical swabs, demonstrating a superior type-specific concordance rate of 100% between urine and cervical swabs, even when using a small volume of urine (300 µL). Conclusion: We envision that PEI-mPpy NWs provide substantive evidence for clinical diagnosis and management of HPV-associated disease with their excellent performance in the recovery and detection of HPV DNA from minimal amounts of urine samples. PMID:29290816

  15. Low cadmium exposure in males and lactating females–estimation of biomarkers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stajnko, Anja

    Background: Urine cadmium (Cd) and renal function biomarkers, mostly analysed in urine spot samples, are well established biomarkers of occupational exposure. Their use and associations at low environmental level are common, but have recently been questioned, particularly in terms of physiological variability and normalisation bias in the case of urine spot samples. Aim: To determine the appropriateness of spot urine and/or blood Cd exposure biomarkers and their relationships with renal function biomarkers at low levels of exposure. To this end, we used data from Slovenian human biomonitoring program involving 1081 Slovenians (548 males, mean age 31 years; 533 lactating females,more » mean age 29 years; 2007–2015) who have not been exposed to Cd occupationally. Results: Geometric means (GMs) of Cd in blood and spot urine samples were 0.27 ng/mL (0.28 for males and 0.33 for females) and 0.19 ng/mL (0.21 for males and 0.17 for females), respectively. Differing results were obtained when contrasting normalisation by urine creatinine with specific gravity. GMs of urine albumin (Alb), alpha-1-microglobulin (A1M), N-acetyl-beta-glucosaminidase (NAG), and immunoglobulin G (IgG) were far below their upper reference limits. Statistical analysis of unnormalised or normalised urine data often yielded inconsistent and conflicting results (or trends), so association analyses with unnormalised data were taken as more valid. Relatively weak positive associations were observed between urine Cd (ng/mL) and blood Cd (β=0.11, p=0.002 for males and β=0.33, p<0.001 for females) and for females between urine NAG and blood Cd (β=0.14, p=0.04). No associations were found between other renal function biomarkers and blood Cd. Associations between Cd and renal function biomarkers in urine were stronger (p<0.05, β=0.11–0.63). Mostly, all of the associations stayed significant but weakened after normalisation for diuresis. In the case of A1M, its associations with Cd were influenced by current smoking and blood Pb in males and by pre-pregnancy smoking and blood Se in females (β up to 0.34, p<0.001). Statistical analysis of unnormalised or normalised urine data often yielded inconsistent and conflicting results (or trends), so association analyses data with unnormalised were taken as more valid. Conclusions: The observed uncertainties introduced by urine normalisation, particularly by creatinine, confirm blood Cd as a superior low-Cd exposure biomarker versus urine Cd in cases when 24 h urine is unattainable. Evidence that A1M can be positively related to Cd, smoking (current or pre-pregnancy), Pb, and Se status, points to the versatile biological functions of A1M. - Highlights: • Creatinine normalisation of spot urine data is inappropriate at low Cd exposure. • Blood Cd as low-Cd exposure biomarker is superior over spot urine Cd. • Cd in urine, but not in blood, was significantly associated with A1M. • A1M – Cd relations were influenced by smoking, Se and less so by Pb.« less

  16. Correlation of the levels of glycosaminoglycans between urine and dried urine in filter paper samples and their stability over time under different storage temperatures.

    PubMed

    Breier, Ana Carolina; Cé, Jaqueline; Coelho, Janice Carneiro

    2014-06-10

    Mucopolysaccharidoses (MPSs) are a group of lysosomal storage diseases caused by the deficiency/absence of enzymes which catalyze the degradation of glycosaminoglycans (GAGs). The use of biological samples dried on filter paper has been increasing because it makes it easy to ship them to reference laboratories. Urinary GAGs are the main biomarkers of MPS and, thus, we studied the correlations of determinations to GAGs and creatinine, as well as compared the GAGs' profile on electrophoresis, between urine and dried urine in filter paper (DUFP) samples. We also assessed the GAG stability over time under different storage temperatures. We quantified the GAG concentration in both sample types and compared the results by Pearson correlation. The results were very similar, with r=0.97 for creatinine and with r=0.94 and r=0.98 for GAGs for controls and patients, respectively, with similar electrophoretic profiles. The GAG stability in DUFP was up to 30days at -20, 4, and 25°C and up to 21days at 37°C. Our proposal assessed urinary GAGs in DUFP and concluded that these samples can be used in the investigation of MPS, replacing urine samples in neonatal screening and monitoring of therapies, due to ease of transportation and storage. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Potential effect of diaper and cotton ball contamination on NMR- and LC/MS-based metabonomics studies of urine from newborn babies.

    PubMed

    Goodpaster, Aaron M; Ramadas, Eshwar H; Kennedy, Michael A

    2011-02-01

    Nuclear magnetic resonance (NMR) and liquid chromatography/mass spectrometry (LC/MS) based metabonomics screening of urine has great potential for discovery of biomarkers for diseases that afflict newborn and preterm infants. However, urine collection from newborn infants presents a potential confounding problem due to the possibility that contaminants might leach from materials used for urine collection and influence statistical analysis of metabonomics data. In this manuscript, we have analyzed diaper and cotton ball contamination using synthetic urine to assess its potential to influence the outcome of NMR- and LC/MS-based metabonomics studies of human infant urine. Eight diaper brands were examined using the "diaper plus cotton ball" technique. Data were analyzed using conventional principal components analysis, as well as a statistical significance algorithm developed for, and applied to, NMR data. Results showed most diaper brands had distinct contaminant profiles that could potentially influence NMR- and LC/MS-based metabonomics studies. On the basis of this study, it is recommended that diaper and cotton ball brands be characterized using metabonomics methodologies prior to initiating a metabonomics study to ensure that contaminant profiles are minimal or manageable and that the same diaper and cotton ball brands be used throughout a study to minimize variation.

  18. Association between Urine Fluoride and Dental Fluorosis as a Toxicity Factor in a Rural Community in the State of San Luis Potosi

    PubMed Central

    Jarquín-Yañez, Lizet; Mejía-Saavedra, José de Jesús; Molina-Frechero, Nelly; Gaona, Enrique; Rocha-Amador, Diana Olivia; López-Guzmán, Olga Dania; Bologna-Molina, Ronell

    2015-01-01

    Objective. The aim of this study is to investigate urine fluoride concentration as a toxicity factor in a rural community in the state of San Luis Potosi, Mexico. Materials and Methods. A sample of 111 children exposed to high concentrations of fluoride in drinking water (4.13 mg/L) was evaluated. Fluoride exposure was determined by measuring urine fluoride concentration using the potentiometric method with an ion selective electrode. The diagnosis of dental fluorosis was performed by clinical examination, and the severity of damage was determined using Dean's index and the Thylstrup-Fejerskov (TF) index. Results. The range of exposure in the study population, evaluated through the fluoride content in urine, was 1.1 to 5.9 mg/L, with a mean of 3.14 ± 1.09 mg/L. Dental fluorosis was present in all subjects, of which 95% had severe cases. Higher urine fluoride levels and greater degrees of severity occurred in older children. Conclusions. The results show that dental fluorosis was determined by the presence of fluoride exposure finding a high positive correlation between the severity of fluorosis and urine fluoride concentration and the years of exposure suggested a cumulative effect. PMID:25789336

  19. Evaluation of urine for Leishmania infantum DNA detection by real-time quantitative PCR.

    PubMed

    Pessoa-E-Silva, Rômulo; Mendonça Trajano-Silva, Lays Adrianne; Lopes da Silva, Maria Almerice; da Cunha Gonçalves-de-Albuquerque, Suênia; de Goes, Tayná Correia; Silva de Morais, Rayana Carla; Lopes de Melo, Fábio; de Paiva-Cavalcanti, Milena

    2016-12-01

    The availability of some sorts of biological samples which require noninvasive collection methods has led to an even greater interest in applying molecular biology on visceral leishmaniasis (VL) diagnosis, since these samples increase the safety and comfort of both patients and health professionals. In this context, this work aimed to evaluate the suitability of the urine as a specimen for Leishmania infantum kinetoplast DNA detection by real-time quantitative PCR (qPCR). Subsequent to the reproducibility analysis, the detection limit of the qPCR assay was set at 5fg (~0.025 parasites) per μL of urine. From the comparative analysis performed with a set of diagnostic criteria (serological and molecular reference tests), concordance value of 96.08% was obtained (VL-suspected and HIV/AIDS patients, n=51) (P>0.05). Kappa coefficient (95% CI) indicated a good agreement between the test and the set of diagnostic criteria (k=0.778±0.151). The detection of Leishmania DNA in urine by qPCR was possible in untreated individuals, and in those with or without suggestive renal impairment. Fast depletion of the parasite's DNA in urine after treatment (from one dose of meglumine antimoniate) was suggested by negative qPCR results, thus indicating it as a potential alternative specimen to follow up the efficacy of therapeutic approaches. Even when evaluated in a clinically heterogeneous set of patients, the urine showed good prospect as sample for VL diagnosis by qPCR, also indicating a good negative predictive value for untreated suspected patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. [Concentration of cysteine proteinase inhibitors in urine, amniotic fluid and serum from women in pregnancy complicated by EPH-gestosis].

    PubMed

    Karmowski, A; Sobiech, K A; Kertyńska, I; Terpiłowski, L; Słowińska-Lisowska, M; Pałczyński, B; Malik, B

    2000-10-01

    Cysteine proteinase inhibitors (IPC) concentration was measured by the modified Barrett method using papaine in urine, amniotic fluid and serum obtained from the healthy labored women and from labored women in pregnancy complicated by EPH-gestosis. It was noticed the statistically significant increase in the IPC concentration in the material from the pregnant women with EPH-gestosis comparing to the women, which pregnancy had the physiologically normal course.

  1. CHANGES IN URINE MARKERS AND SYMPTOMS AFTER BLADDER DISTENTION FOR INTERSTITIAL CYSTITIS

    PubMed Central

    Erickson, Deborah R.; Kunselman, Allen R.; Bentley, Christina M.; Peters, Kenneth M.; Rovner, Eric S.; Demers, Laurence M.; Wheeler, Marcia A.; Keay, Susan K.

    2008-01-01

    Purpose To evaluate changes in urine markers and symptom scores after bladder distention in interstitial cystitis (IC) patients. Materials and Methods Subjects were 33 new patients with no prior IC treatments. Urine specimens were taken before and one month after bladder distention. University of Wisconsin (UW) symptom scores were done the same day as the urine specimen collection. Urine marker levels and symptom scores before and after distention were compared. Changes in markers were tested for associations with changes in symptom scores and other markers. Pre-distention markers and specific pre-distention symptoms were tested for their association with post-distention symptom improvement. Results After distention, the median total UW score decreased significantly (28.5 before, 10 after, p<0.001). Twelve patients (36%) had at least 30% improvement in UW score, and eight patients (24%) had at least 50% improvement. No pre-distention markers or symptoms predicted which patients would have a good response. Two of the urine markers improved significantly after distention: anti-proliferative factor (APF) activity (median −96% before, −17% after, p< 0.001) and heparin binding-epidermal growth factor-like growth factor (HB-EGF) levels (median 0.34 ng/mg creatinine before, 4.1 after, p<0.001). None of the changes in urine markers associated with changes in symptom scores. Conclusions The median symptom score for newly diagnosed IC patients decreased after distention, but only a minority of patients had at least 30% symptom improvement. Bladder distention altered urine APF activity and HB-EGF levels towards normal, but the mechanism of symptom relief after distention is still unknown. PMID:17222633

  2. Quantitative determinations of levofloxacin and rifampicin in pharmaceutical and urine samples using nuclear magnetic resonance spectroscopy

    NASA Astrophysics Data System (ADS)

    Salem, A. A.; Mossa, H. A.; Barsoum, B. N.

    2005-11-01

    Rapid, specific and simple methods for determining levofloxacin and rifampicin antibiotic drugs in pharmaceutical and human urine samples were developed. The methods are based on 1H NMR spectroscopy using maleic acid as an internal standard and DMSO-d6 as NMR solvent. Integration of NMR signals at 8.9 and 8.2 ppm were, respectively, used for calculating the concentration of levofloxacin and rifampicin drugs per unit dose. Maleic acid signal at 6.2 ppm was used as the reference signal. Recoveries of (97.0-99.4) ± 0.5 and (98.3-99.7) ± 1.08% were obtained for pure levofloxacin and rifampicin, respectively. Corresponding recoveries of 98.5-100.3 and 96.8-100.0 were, respectively, obtained in pharmaceutical capsules and urine samples. Relative standard deviations (R.S.D.) values ≤2.7 were obtained for analyzed drugs in pure, pharmaceutical and urine samples. Statistical Student's t-test gave t-values ≤2.87 indicating insignificant difference between the real and the experimental values at the 95% confidence level. F-test revealed insignificant difference in precisions between the developed NMR methods and each of fluorimetric and HPLC methods for analyzing levofloxacin and rifampicin.

  3. Two low-cost digital camera-based platforms for quantitative creatinine analysis in urine.

    PubMed

    Debus, Bruno; Kirsanov, Dmitry; Yaroshenko, Irina; Sidorova, Alla; Piven, Alena; Legin, Andrey

    2015-10-01

    In clinical analysis creatinine is a routine biomarker for the assessment of renal and muscular dysfunctions. Although several techniques have been proposed for a fast and accurate quantification of creatinine in human serum or urine, most of them require expensive or complex apparatus, advanced sample preparation or skilled operators. To circumvent these issues, we propose two home-made platforms based on a CD Spectroscope (CDS) and Computer Screen Photo-assisted Technique (CSPT) for the rapid assessment of creatinine level in human urine. Both systems display a linear range (r(2) = 0.9967 and 0.9972, respectively) from 160 μmol L(-1) to 1.6 mmol L(-1) for standard creatinine solutions (n = 15) with respective detection limits of 89 μmol L(-1) and 111 μmol L(-1). Good repeatability was observed for intra-day (1.7-2.9%) and inter-day (3.6-6.5%) measurements evaluated on three consecutive days. The performance of CDS and CSPT was also validated in real human urine samples (n = 26) using capillary electrophoresis data as reference. Corresponding Partial Least-Squares (PLS) regression models provided for mean relative errors below 10% in creatinine quantification. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. [Nickel levels in female dermatological patients].

    PubMed

    Schwegler, U; Twardella, D; Fedorov, M; Darsow, U; Schaller, K-H; Habernegg, R; Behrendt, H; Fromme, H

    2009-07-01

    Nickel levels in urine were determined among 163 female dermatological patients aged 18 to 46 years. Data on life-style factors were collected in parallel via a questionnaire. Urinary nickel excretion was in the normal range of the German female population (0.2-46.1 microg Ni/g creatinine). The 95th percentile (3.9 microg Ni/l urine) exceeded the German reference value (3.0 microg Ni/l urine). In the multivariate regression analyses we found a statistically significant increase of ln-transformed nickel levels with increase in age and in women using dietary supplements. The following variables were not associated with Nickel urine levels: suffering from nickel eczema, smoking, drinking stagnated water, eating foods with high nickel contents and using nickel-containing kitchen utensils as, for example, an electric kettle with an open heater coil. We conclude that personal urinary levels should be assessed with simultaneous consideration of habits and life-style factors. A German national survery would be useful. Those patients who experience the exacerbation of their eczema in cases of oral provocation, for example, by a high nickel diet should be aware of potential sources of nickel, such as supplements.

  5. [Urine metabonomic study on long-term use of total ginsenosides in rats].

    PubMed

    Xie, Xie; Chen, Shao-Qiu; Lv, Ying-Fang; Wang, Xiao-Yan; Jia, Wei

    2014-12-01

    Due to its effect of systems regulation and promotion on body, Ginseng is always referred to be long-term used as a dietary supplement. But it was still unclear about its target of the tonic effects and also the side-effects long-term use may bring. Urine metabolomic method is suitable for long-term studies of pharmaco-dynamics, pharmacology and toxicology of traditional Chinese medicine because of its characteristics of non-invasive and monitoring the whole-body metabolism. This study was designed to detect the dynamic variation of rat urine metabolome along with a long-term administration of total ginsenosides using GC-TOF based metabolomic technology. Our result showed that either short-term or chronic administration of ginsenosides did not impact the rat urine metabolome significantly (as the PCA subgroup was not successful). By comparison, the short-term (1-3 w) dose of ginsenosides had the biggest metabolic influence including TCA cycle, catecholamines and neurotransmitter amino acids. Medium-term (6-10 w) dose had a gradually lower effect and long-term (27 w) dose almost had no effect. Our study indicates that both short and long-term administration of ginsenosides showed almost no obvious side-effect on the experimental animals.

  6. Urine Pretreatment History and Perspective in NASA Human Spaceflight

    NASA Technical Reports Server (NTRS)

    Anderson, Molly; Adam, Niklas; Chambers, Antja; Broyan, James

    2015-01-01

    Urine pretreatment is a technology that may seem to have small mass impacts in future spaceflight missions, but can have significant impacts on reliability, life, and performance of the rest of the wastewater management and recovery systems. NASA has experience with several different urine pretreatment systems, including those flow on the space shuttle, evaluated for NASA waste collection systems or used in Russian commodes on ISS, or developed by NASA or industry as alternatives. Each has had unique requirements for shelf life, operational life, and the life or conditions of the stored, treated urine. Each was evaluated under different test conditions depending on mission, and depending on testing experience developed over NASA's history. Those that were flown led to further lessons learned about hardware compatibility and control. As NASA looks forward to human spaceflight missions beyond low Earth orbit, these techniques need to be evaluated in new light. Based on published design reference missions, candidate requirements can be derived for future systems. Initial comparisons between these requirements and previous performance or test results can be performed. In many cases these comparisons reveal data gaps. Successful previous performance is not enough to address current needs.

  7. [Bacterial and fungal flora in some clinical materials in children with diabetes type 1].

    PubMed

    Nowakowska, Maria; Jarosz-Chobot, Przemysława

    2002-01-01

    Children with poorly controlled diabetes are exposed to infections often caused by endogenous flora. To estimate incidence of pathogenic and opportunistic bacteria and fungi of Candida species. The urine, smears from the oral cavity and the pharynx as well as from the urogenital tract were examined in 130 children (62 boys and 68 girls) hospitalised because of newly diagnosed (53 children) or poorly controlled diabetes (77 patients). 29 children with short stature were the control group, in these children only the urine and smears from the oral cavity and the pharynx were only examined. Culture and identification of microorganisms were performed according to the methods used in microbiological diagnosis. Antifungal susceptibility testing was estimated with FUNGITEST Sanofi Pasteur and ATB Fungus bioMérieux. Staphylococcus aureus in 43 diabetic children (33%) was observed. Staphylococcus aureus from different clinical materials was isolated; there was no difference in the frequency of occurrence of S. aureus in flora of the oral cavity and the pharynx in diabetic children in comparison with healthy children. Streptococcus group B in 29 (22.3%) was isolated, among them in 10 children from the pharynx. In healthy children Streptococcus group B was not observed. A significant bacteriuria was observed in 15 diabetic children (11.5%) and in 2 healthy children (6.9%). Fungi in 58 diabetic children (44.6%) were observed. Most often isolated species was Candida albicans (49 children), rarely other species. Candida spp. from different clinical materials was isolated, also in a non significant amount from the urine. Microbial analysis of vagina should be routinely performed in diabetic adolescents. Urine of diabetics should be examined towards fungi.

  8. Contemporary Attitudes and Practice Patterns of North American Urologists in Investigating Stone-Forming Patients-A Survey of Endourological Society Members.

    PubMed

    McGuire, Barry B; Matulewicz, Richard S; Zuccarino-Crowe, Rian; Nadler, Robert B; Perry, Kent T

    2016-04-01

    Recent evidence would suggest a low rate of metabolic assessment in stone formers, even in those deemed as high risk. We wished to assess the attitudes and practice patterns of metabolic work up in North American members of the Endourological Society as part of the management of stone-forming patients. A 12-question online multiple-choice questionnaire (using Survey Monkey(®)) was distributed to all members of the Endourological Society through e-mail. Descriptive analyses were performed. A total of 124 North American members of the Endourological Society responded (90% endourologists, 65% fellowship trained). Ninety-seven percent perform metabolic assessments without referring to a consultant. Eighty-three percent use a commercial analysis company and 17% request serum or urine parameters individually. Ninety-seven percent believe that 24-48-hour urine collection is a better way of assessing patients for metabolic abnormalities than a "basic analysis." Many respondents (37%) would be more likely to metabolically assess if results were easier to interpret, and 35% would like assistance/advice in the interpretation of results. At initial investigation of a first-time stone former, 87% of respondents use serum chemistry, 48% use 24-hour urine, 26% use 48-hour urine (two consecutive 24-hour urine collections), 54% send stone for analysis, and 7% do not investigate. On recurrent stone formers, 69% use serum chemistry, 73% use 24/48-hour urine, and 23% send stone for analysis. On routine follow-up, 36% check serum chemistry, 55% use 24-hour urine, 2% use 48-hour urine, and 29% do not metabolically evaluate. The majority agree that pharmacologic therapy plays a strong role in preventing recurrence (90%). After initiating pharmacologic therapy, 59% reassess using serum chemistry and 84% and 7% use 24/48-hour urine collection, respectively. Physicians re-evaluate patients after 1 month (7%), 1-2 months (10%), 2-4 months (44%), 4-6 months (30%), or after 6-12 months (7%). This snapshot assessment of Endourological Society members' practices in the metabolic investigation of stone-forming patients demonstrates wide testing variations. Many physicians expressed interest in assistance/advice in the interpretation of the metabolic assessment results.

  9. Water-loss (intracellular) dehydration assessed using urinary tests: how well do they work? Diagnostic accuracy in older people.

    PubMed

    Hooper, Lee; Bunn, Diane K; Abdelhamid, Asmaa; Gillings, Rachel; Jennings, Amy; Maas, Katie; Millar, Sophie; Twomlow, Elizabeth; Hunter, Paul R; Shepstone, Lee; Potter, John F; Fairweather-Tait, Susan J

    2016-07-01

    Water-loss dehydration (hypertonic, hyperosmotic, or intracellular dehydration) is due to insufficient fluid intake and is distinct from hypovolemia due to excess fluid losses. Water-loss dehydration is associated with poor health outcomes such as disability and mortality in older people. Urine specific gravity (USG), urine color, and urine osmolality have been widely advocated for screening for dehydration in older adults. We assessed the diagnostic accuracy of urinary measures to screen for water-loss dehydration in older people. This was a diagnostic accuracy study of people aged ≥65 y taking part in the DRIE (Dehydration Recognition In our Elders; living in long-term care) or NU-AGE (Dietary Strategies for Healthy Ageing in Europe; living in the community) studies. The reference standard was serum osmolality, and index tests included USG, urine color, urine osmolality, urine cloudiness, additional dipstick measures, ability to provide a urine sample, and the volume of a random urine sample. Minimum useful diagnostic accuracy was set at sensitivity and specificity ≥70% or a receiver operating characteristic plot area under the curve ≥0.70. DRIE participants (women: 67%; mean age: 86 y; n = 162) had more limited cognitive and functional abilities than did NU-AGE participants (women: 64%; mean age: 70 y; n = 151). Nineteen percent of DRIE participants and 22% of NU-AGE participants were dehydrated (serum osmolality >300 mOsm/kg). Neither USG nor any other potential urinary tests were usefully diagnostic for water-loss dehydration. Although USG, urine color, and urinary osmolality have been widely advocated for screening for dehydration in older adults, we show, in the largest study to date to our knowledge, that their diagnostic accuracy is too low to be useful, and these measures should not be used to indicate hydration status in older people (either alone or as part of a wider tranche of tests). There is a need to develop simple, inexpensive, and noninvasive tools for the assessment of dehydration in older people. The DRIE study was registered at www.researchregister.org.uk as 122273. The NU-AGE trial was registered at clinicialtrials.gov as NCT01754012. © 2016 American Society for Nutrition.

  10. Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas.

    PubMed

    Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick M M; Leeflang, Mariska M G

    2015-03-11

    Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopyCompared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21).When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assayCompared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy.The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy.

  11. A phase I study to assess the mass balance, excretion, and pharmacokinetics of [14C]-ixazomib, an oral proteasome inhibitor, in patients with advanced solid tumors.

    PubMed

    Gupta, Neeraj; Zhang, Steven; Pusalkar, Sandeepraj; Plesescu, Mihaela; Chowdhury, Swapan; Hanley, Michael J; Wang, Bingxia; Xia, Cindy; Zhang, Xiaoquan; Venkatakrishnan, Karthik; Shepard, Dale R

    2018-06-01

    This two-part, phase I study evaluated the mass balance, excretion, pharmacokinetics (PK), and safety of ixazomib in patients with advanced solid tumors. In Part A of the study, patients received a single 4.1 mg oral solution dose of [ 14 C]-ixazomib containing ~500 nCi total radioactivity (TRA), followed by non-radiolabeled ixazomib (4 mg capsule) on days 14 and 21 of the 35-day PK cycle. Patients were confined to the clinic for the first 168 h post dose and returned for 24 h overnight clinic visits on days 14, 21, 28, and 35. Blood, urine, and fecal samples were collected during Part A to assess the mass balance (by accelerator mass spectrometry), excretion, and PK of ixazomib. During Part B of the study, patients received non-radiolabeled ixazomib (4 mg capsules) on days 1, 8, and 15 of 28-day cycles. After oral administration, ixazomib was rapidly absorbed with a median plasma T max of 0.5 h and represented 70% of total drug-related material in plasma. The mean total recovery of administered TRA was 83.9%; 62.1% in urine and 21.8% in feces. Only 3.23% of the administered dose was recovered in urine as unchanged drug up to 168 h post dose, suggesting that most of the TRA in urine was attributable to metabolites. All patients experienced a treatment-emergent adverse event, which most commonly involved the gastrointestinal system. These findings suggest that ixazomib is extensively metabolized, with urine representing the predominant route of excretion of drug-related material.Trial ID: ClinicalTrials.gov # NCT01953783.

  12. Human exposure to airborne aniline and formation of methemoglobin: a contribution to occupational exposure limits.

    PubMed

    Käfferlein, Heiko Udo; Broding, Horst Christoph; Bünger, Jürgen; Jettkant, Birger; Koslitz, Stephan; Lehnert, Martin; Marek, Eike Maximilian; Blaszkewicz, Meinolf; Monsé, Christian; Weiss, Tobias; Brüning, Thomas

    2014-07-01

    Aniline is an important starting material in the manufacture of polyurethane-based plastic materials. Aniline-derived methemoglobinemia (Met-Hb) is well described in exposed workers although information on the dose-response association is limited. We used an experimental design to study the association between aniline in air with the formation of Met-Hb in blood and the elimination of aniline in urine. A 6-h exposure of 2 ppm aniline in 19 non-smoking volunteers resulted in a time-dependent increase in Met-Hb in blood and aniline in urine. The maximum Met-Hb level in blood (mean 1.21 ± 0.29 %, range 0.80-2.07 %) and aniline excretion in urine (mean 168.0 ± 51.8 µg/L, range 79.5-418.3 µg/L) were observed at the end of exposure, with both parameters rapidly decreasing after the end of exposure. After 24 h, the mean level of Met-Hb (0.65 ± 0.18 %) returned to the basal level observed prior to the exposure (0.72 ± 0.19 %); whereas, slightly elevated levels of aniline were still present in urine (means 17.0 ± 17.1 vs. 5.7 ± 3.8 µg/L). No differences between males and females as well as between slow and fast acetylators were found. The results obtained after 6-h exposure were also comparable to those observed in four non-smoking volunteers after 8-h exposure. Maximum levels of Met-Hb and aniline in urine were 1.57 % and 305.6 µg/L, respectively. Overall, our results contribute to the risk assessment of aniline and as a result, the protection of workers from aniline-derived adverse health effects at the workplace.

  13. Diagnostic reference range of κ/λ free light chain ratio to screen for Bence Jones proteinuria is not significantly influenced by GFR.

    PubMed

    Schmidt-Hieltjes, Yvonne; Elshof, Clemens; Roovers, Lian; Ruinemans-Koerts, Janneke

    2016-05-01

    The aim of our study was to analyse whether the κ/λ free light chain ratio reference range for screening for Bence Jones proteinuria should be dependent on the estimated glomerular filtration rate (eGFR). The serum κ/λ free light chain ratio, eGFR, serum M-protein and Bence Jones protein were measured in 544 patients for whom Bence Jones protein analysis was ordered. In the population of patients without Bence Jones proteinuria or a M-protein (n = 402), there is no gradual increase in κ/λ free light chain ratio with diminishing eGFR. The κ/λ free light chain ratio in this group was 0.56-1.86 (95% interval). With this diagnostic reference range of the κ/λ ratio, 105 of the 110 patients with Bence Jones protein could be identified correctly. Only five patients with Bence Jones proteinuria (<0.17 g/L) were missed, without diagnostic or therapeutic consequences. In 36 patients (6.6%), an abnormal κ/λ free light chain ratio was measured without the presence of Bence Jones proteinuria. A κ/λ free light chain ratio in serum can be used safely and efficiently to select urine samples which should be analysed for Bence Jones proteinuria with an electrophoresis/immunofixation technique. Using this diagnostic reference range, the number of urine samples which should be analysed by electrophoresis/immunofixation could be reduced by 74%. The diagnostic reference interval can be determined best in a group of patients for whom Bence Jones analysis is indicated. For calculation of this reference range, the eGFR value does not need to be taken into account. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Pediatric reference intervals for random urine calcium, phosphorus and total protein.

    PubMed

    Slev, Patricia R; Bunker, Ashley M; Owen, William E; Roberts, William L

    2010-09-01

    The aim of this study was to establish age appropriate reference intervals for calcium (Ca), phosphorus (P) and total protein (UTP) in random urine samples. All analytes were measured using the Roche MODULAR P analyzer and normalized to creatinine (Cr). Our study cohort consisted of 674 boys and 728 girls between 7 and 17 years old (y.o.), which allowed us to determine the central 95% reference intervals with 90% confidence intervals by non-parametric analysis partitioned by both gender and 2-year age intervals for each analyte [i.e. boys in age group 7-9 years (7-9 boys); girls in age group 7-9 years (7-9 girls), etc.]. Results for the upper limits of the central 95% reference interval were: for Ca/Cr, 0.27 (16,17 y.o.) to 0.46 mg/mg (7-9 y.o.) for the girls and 0.26 (16,17 y.o.) to 0.43 mg/mg (7-9 y.o.) for the boys; for P/Cr, 0.85 (16,17 y.o.) to 1.44 mg/mg (7-9 y.o.) for the girls and 0.87 (16,17 y.o.) to 1.68 mg/mg (7-9 y.o.) for the boys; for UTP/Cr, 0.30 (7-9 y.o.) to 0.34 mg/mg (10-12 y.o.) for the girls and 0.19 (16,17, y.o.) to 0.26 mg/mg (13-15 y.o.) for the boys. Upper reference limits decreased with increasing age, and age was a statistically significant variable for all analytes. Eight separate age- and gender-specific reference intervals are proposed per analyte.

  15. Markers of Renal Function and Injury

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ragan, Harvey A.; Weller, Richard E.

    1999-04-15

    Designed to aid the laboratory animal veterinarian, researcher, or toxicologist in the proper evaluation of organ function, this updated and revised edition provides the only comprehensive reference of the clinical chemistry of laboratory animals. With contributions from recognized experts in the field, new chapters are included that focus on the pig and the ferret, while many chapters have been rewritten. Expanded coverage was given to urine chemistry, hormones, including melatonin, and the control mechanisms of analytes. Reference values are given in both conventional and S.I. units.

  16. A study of the influence on diabetes of free and conjugated bisphenol A concentrations in urine: Development of a simple microextraction procedure using gas chromatography-mass spectrometry.

    PubMed

    Pastor-Belda, Marta; Bastida, David; Campillo, Natalia; Pérez-Cárceles, María D; Motas, Miguel; Viñas, Pilar

    2016-09-10

    The association between bisphenol A (BPA) exposure and adult health status is examined by measuring the urinary BPA concentration using a miniaturized technique based on dispersive liquid-liquid microextraction (DLLME) in combination with gas chromatography-mass spectrometry (GC-MS). Both the free bioactive and the glucuronide conjugated forms of BPA were measured, the glucuronide form usually being predominant. The main analogs of BPA, including bisphenol Z (BPZ), bisphenol F (BPF) and biphenol (BP) were also determined. Several parameters affecting enzymatic hydrolysis, derivatization by in-situ acetylation and the DLLME stages were carefully optimized by means of multivariate designs. DLLME parameters were 2mL urine, 1mL acetone and 100μL chloroform, and hydrolysis was performed using β-glucuronidase and sulfatase at pH 5. No matrix effect was observed and quantification was carried out by aqueous calibration with a surrogate standard. Detection limits were in the range 0.01-0.04ngmL(-1). The intraday and interday precisions were lower than 11% in terms of relative standard deviation. Satisfactory values for all compounds were obtained in recovery studies (92-117%) at two concentration levels. Other bisphenols (BPF, BPZ and BP) were not detected in the urine samples, while BPA was the only bisphenol detected in the free form (creatinine adjusted) at concentration levels ranging from the detection limit to 15.9ngg(-1), and total BPA was detected at concentrations ranging from 0.46 to 24.5ngg(-1) levels. A comparison of the BPA content for both groups of patients revealed that slightly higher mean values were obtained for both free BPA and total BPA for diabetic patients, than for non-diabetic patients. However, a statistical comparison of the contents of BPA revealed that there were no significant differences. The procedure was validated using a certified reference material. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Urinary Peptides in Rett Syndrome.

    ERIC Educational Resources Information Center

    Solaas, K. M.; Skjeldal, O.; Gardner, M. L. G.; Kase, B. F.; Reichelt, K. L.

    2002-01-01

    A study found a significantly higher level of peptides in the urine of 53 girls with Rett syndrome compared with controls. The elevation was similar to that in 35 girls with infantile autism. Levels of peptides were lower in girls with classic Rett syndrome than those with congenital Rett syndrome. (Contains references.) (Author/CR)

  18. 16 CFR 305.19 - Promotional material displayed or distributed at point of sale.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT... distribution at point-of-sale concerning a covered product that is a showerhead, faucet, water closet, or urinal shall clearly and conspicuously include in such printed material the product's water use...

  19. 16 CFR 305.19 - Promotional material displayed or distributed at point of sale.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT... distribution at point-of-sale concerning a covered product that is a showerhead, faucet, water closet, or urinal shall clearly and conspicuously include in such printed material the product's water use...

  20. Molecularly imprinted polymers for separation of various sugars from human urine.

    PubMed

    Okutucu, Burcu; Onal, Seçil

    2011-12-15

    Molecularly imprinted polymers were the new, simple and unexpensive materials that can be used in several clinical applications. Phenylboronic acid has been frequently used as functional monomer for the covalent imprinting of diols. In this study, the phenylboronic acid esters of fructose, galactose, glucose and raffinose were synthesized and then used as template analytes. The adsorption capacities of fructose, galactose and glucose-phenylboronic acid imprinted polymers were 75, 10 and 30%, respectively. The batch rebinding studies and Scatchard analysis were done for all sugar imprinted polymer. Glucose is one of the mostly found sugar in the urine. The glucose:phenylboronic acid imprinted polymer was used for the analysis of glucose, fructose, galactose, sucrose, maltose, lactose and raffinose in spiked urine. The selectivity of glucose:phenylboronic acid imprinted polymer to urine monosaccharides was found as nearly 45-55% and to di- and polysaccharides was found as 30-35%, respectively. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    PubMed

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  2. Quantitative electrochemical metalloimmunoassay for TFF3 in urine using a paper analytical device.

    PubMed

    DeGregory, Paul R; Tsai, Yi-Ju; Scida, Karen; Richards, Ian; Crooks, Richard M

    2016-03-07

    We report a paper-based assay platform for the detection of the kidney disease marker Trefoil Factor 3 (TFF3) in human urine. The sensor is based on a quantitative metalloimmunoassay that can determine TFF3 concentrations via electrochemical detection of environmentally stable silver nanoparticle (AgNP) labels attached to magnetic microbeads via a TFF3 immunosandwich. The paper electroanalytical device incorporates two preconcentration steps that make it possible to detect concentrations of TFF3 in human urine at the low end of the target TFF3 concentration range (0.03-7.0 μg mL(-1)). Importantly, the paper device provides a level of accuracy for TFF3 determination in human urine equivalent to that of a commercial kit. The paper sensor has a dynamic range of ∼2.5 orders of magnitude, only requires a simple, one-step incubation protocol, and is fast, requiring only 10 min to complete. The cost of the materials at the prototypic laboratory scale, excluding reagents, is just US$0.42.

  3. Determination of sulfates and glucuronides of endogenic steroids in biofluids by high-performance liquid chromatography/orbitrap mass spectrometry

    NASA Astrophysics Data System (ADS)

    Semenistaya, E. N.; Virus, E. D.; Rodchenkov, G. M.

    2009-04-01

    the possibility of selective determination of testosterone and epitestosterone glucuronides in urine by high-performance liquid chromatography/high-resolution mass spectrometry using solid phase microextraction on a meps cartridge was studied. the effect of the biological matrix on the spectra of conjugated steroids can be taken into account by using the spectra of conjugates recorded for urine samples after hydrolysis as reference spectra. the conditions of fragmentation in the ion source were optimized for separate analytes. this method was used for analyzing real samples with different testosterone/epitestosterone ratios. variations in conjugate contents and qualitative changes in the steroid profile of endogenic compounds were observed.

  4. Microbiological and corrosion analysis of three urine pretreatment regimes with titanium 6A1-4V

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1993-01-01

    One objective of the water recovery test (WRT) performed at NASA's Marshall Space Flight Center (MSFC) for the environmental control and life support systems (ECLSS) of Space Station Freedom is to determine the ability of the water recovery system to reclaim urine for crew reuse. In the process, raw urine is pretreated using a commercially available oxidant, Oxone (Dupont), and sulfuric acid (to reduce ammonia), and pumped into a urine processing subsystem. A combination of sodium hypochlorite and sulfuric acid were also considered as an alternative pretreatment. The ability of these pretreatments, plus a third pretreatment of ozone, to reduce microbial levels in urine generated during testing of the water recovery system at MSFC was examined. In addition, the corrosion rate of weld and base metal specimens of titanium 6A1-4V, a candidate material for the water system of Space Station Freedom, was monitored in the presence of these pretreatments. Specimen surfaces were examined at completion of the 21-day test using scanning electron microscopy. Change in pH, color, turbidity, and odor were recorded over the course of the test.

  5. Recovery of urinary nanovesicles from ultracentrifugation supernatants.

    PubMed

    Musante, Luca; Saraswat, Mayank; Ravidà, Alessandra; Byrne, Barry; Holthofer, Harry

    2013-06-01

    Urinary vesicles represent a newly established source of biological material, widely considered to faithfully represent pathological events in the kidneys and the urogenital epithelium. The majority of currently applied isolation protocols involve cumbersome centrifugation steps to enrich vesicles from urine. To date, the efficiency of these approaches has not been investigated with respect to performing quantitative and qualitative analyses of vesicle populations in the pellet and supernatant (SN) fractions. After the series of differential centrifugations, the final SN was reduced to one-twentieth of the original volume by ammonium sulphate precipitation, with the precipitate pellet subjected to another round of differential centrifugations. Electron microscopy, dynamic light scattering and western blot analysis were used to characterize the vesicles present in individual fractions of interest. Pellets obtained after the second set of centrifugations at 200 000 g revealed the presence of vesicles which share a common marker profile, but with distinct differences from those seen in the initial 200 000 g pellet used as the reference. This suggests an enrichment of previously uncharacterized urinary vesicles still in solution after the initial centrifugation steps. Analysis of protein yields recovered post-ultracentrifugation revealed an additional 40% of vesicles retained from the SN. Moreover, these structures showed a formidable resistance to harsh treatments (e.g. 95% ammonium sulphate saturation, hypotonic dialysis, 0.3 M sodium hydroxide). Methods which employ differential centrifugations of native urine are remarkably ineffective and may lose a substantial population of biologically important vesicle species.

  6. An electrochemical albumin-sensing system utilizing microfluidic technology

    NASA Astrophysics Data System (ADS)

    Huang, Chao-June; Lu, Chiu-Chun; Lin, Thong-Yueh; Chou, Tse-Chuan; Lee, Gwo-Bin

    2007-04-01

    This paper reports an integrated microfluidic chip capable of detecting the concentration of albumin in urine by using an electrochemical method in an automatic format. The integrated microfluidic chip was fabricated by using microelectromechanical system techniques. The albumin detection was conducted by using the electrochemical sensing method, in which the albumin in urine was detected by measuring the difference of peak currents between a bare reference electrode and an albumin-adsorption electrode. To perform the detection of the albumin in an automatic format, pneumatic microvalves and micropumps were integrated onto the microfluidic chip. The albumin sample and interference mixture solutions such as homovanillic acid, dopamine, norepinephrine and epinephrine were first stored in one of the three reservoirs. Then the solution comprising the albumin sample and interference solutions was transported to pass through the detection zone utilizing the pneumatic micropump. Experimental data showed that the developed system can successfully detect the concentration of the albumin in the existence of interference materials. When compared with the traditional albumin-sensing method, smaller amounts of samples were required to perform faster detection by using the integrated microfluidic chip. Additionally, the microfluidic chip integrated with pneumatic micropumps and microvalves facilitates the transportation of the samples in an automatic mode with lesser human intervention. The development of the integrated microfluidic albumin-sensing system may be promising for biomedical applications. Preliminary results of the current paper were presented at the 2nd International Meeting on Microsensors and Microsystems 2006 (National Cheng Kung University, Tainan, Taiwan, 15-18 January).

  7. Evaluation of bioaccumulation kinetics of gold nanorods in vital mammalian organs by means of total reflection X-ray fluorescence spectrometry.

    PubMed

    Fernández-Ruiz, Ramón; Redrejo, María Jesús; Friedrich, Eberhardt Josué; Ramos, Milagros; Fernández, Tamara

    2014-08-05

    This work presents the first application of total-reflection X-ray fluorescence (TXRF) spectrometry, a new and powerful alternative analytical method, to evaluation of the bioaccumulation kinetics of gold nanorods (GNRs) in various tissues upon intravenous administration in mice. The analytical parameters for developed methodology by TXRF were evaluated by means of the parallel analysis of bovine liver certified reference material samples (BCR-185R) doped with 10 μg/g gold. The average values (n = 5) achieved for gold measurements in lyophilized tissue weight were as follows: recovery 99.7%, expanded uncertainty (k = 2) 7%, repeatability 1.7%, detection limit 112 ng/g, and quantification limit 370 ng/g. The GNR bioaccumulation kinetics was analyzed in several vital mammalian organs such as liver, spleen, brain, and lung at different times. Additionally, urine samples were analyzed to study the kinetics of elimination of the GNRs by this excretion route. The main achievement was clearly differentiating two kinds of behaviors. GNRs were quickly bioaccumulated by highly vascular filtration organs such as liver and spleen, while GNRs do not show a bioaccumulation rates in brain and lung for the period of time investigated. In parallel, urine also shows a lack of GNR accumulation. TXRF has proven to be a powerful, versatile, and precise analytical technique for the evaluation of GNRs content in biological systems and, in a more general way, for any kind of metallic nanoparticles.

  8. The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting

    PubMed Central

    Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman

    2016-01-01

    Introduction The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. Materials and methods 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer® Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Results Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Conclusions Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible. PMID:27346967

  9. Human urine as test material in 1H NMR-based metabonomics: recommendations for sample preparation and storage.

    PubMed

    Lauridsen, Michael; Hansen, Steen H; Jaroszewski, Jerzy W; Cornett, Claus

    2007-02-01

    Metabonomic approaches are believed to have the capability of revolutionizing diagnosis of diseases and assessment of patient conditions after medical interventions. In order to ensure comparability of metabonomic 1H NMR data from different studies, we suggest validated sample preparation guidelines for human urine based on a stability study that evaluates effects of storage time and temperature, freeze-drying, and the presence of preservatives. The results indicated that human urine samples should be stored at or below -25 degrees C, as no changes in the 1H NMR fingerprints have been observed during storage at this temperature for 26 weeks. Formation of acetate, presumably due to microbial contamination, was occasionally observed in samples stored at 4 degrees C without addition of a preservative. Addition of a preserving agent is not mandatory provided that the samples are stored at -25 degrees C. Thus, no differences were observed between 1H NMR spectra of nonpreserved urines and urines with added sodium azide and stored at -25 degrees C, whereas the presence of sodium fluoride caused a shift of especially citrate resonances. Freeze-drying of urine and reconstitution in D2O at pH 7.4 resulted in the disappearance of the creatinine CH2 signal at delta 4.06 due to deuteration. A study evaluating the effects of phosphate buffer concentration on signal variability and assessment of the probability of citrate or creatinine resonances crossing bucket border (a boundary between adjacent integrated regions) led to the conclusion that a minimum buffer concentration of 0.3 M is adequate for normal urines used in this study. However, final buffer concentration of 1 M will be required for very concentrated urines.

  10. Nephrology in A Medicinal Dictionary of Robert James (1703-1776).

    PubMed

    Bisaccia, Carmela; De Santo, Natale G; Cirillo, Massimo; Perna, Alessandra; De Santo, Rosalba; Richet, Gabriel

    2011-01-01

    Robert James was a member of the College of Physicians at Cambridge and a practitioner. He was considered one of the "three best known characters in London--perhaps in Europe. The other two being the lexycographer Samuel Johnson and the Shakespearean actor David Garrick." James became famous for his powerful ability to write and publish, which produced many books, including the ponderous A Medicinal Dictionary, With a History of Drugs, in 3 volumes in folio, published in London in the years 1743-1745, and dedicated to the famous professor and royal physician John Mead. The Dictionary was translated into French by Denis Diderot, François-Vincent Toussaint and Marc Antoine Eidous, and was revised by Juliene T. Busson, president of the University of Paris. During the translation, Diderot learned much biology and medicine, which he used subsequently in developing his Encyclopédie. Interesting chapters are devoted to urine, predictions from urine, bloody urine, good urine, bad urine, urine portending death, diabetes, dropsy, nephritis, stone, ischury, dysury and urine incontinence. In general their strength resides in their accurate clinical descriptions. The paragraphs on urine are concise and clinically sound, and the description of procedures for urine analysis and the utilization of results (quantity, quantity, colors, sediments and consistency) in diagnosis and prognosis of bloody urine is accurate. The section on diabetes is excellent and is comparable to that of Desault written decades later in the Encyclopédie of Diderot. In the chapter on dropsy (he does not use the word oedema), patients are well described and their remedies are appropriate for the time. The contributions of kidney and liver are clear. The plants for renal treatment can be traced to Dioscorides. Concerning dosage, he is precise and helpful to his readers. The chapter on stones is a real masterpiece, clinically well centered and giving all the pertinent information to localize them, their medical treatment and the risks of surgery. The entry on nephritis is short and rather confusing. Here James even lacks the usual accurate description of cases which could have made it understandable. Blood letting was extensively used in those days, and he is a man of his time, but James was aware of the clinical conditions where it fails. It is understandable that he underlines its role in certain bloody urines in patients with a plethoric constitution. Was James referring to patients with acute nephritis and possibly high blood pressure.

  11. Variation of betaine, N,N-dimethylglycine, choline, glycerophosphorylcholine, taurine and trimethylamine-N-oxide in the plasma and urine of overweight people with type 2 diabetes over a two-year period.

    PubMed

    McEntyre, Christopher J; Lever, Michael; Chambers, Stephen T; George, Peter M; Slow, Sandy; Elmslie, Jane L; Florkowski, Christopher M; Lunt, Helen; Krebs, Jeremy D

    2015-05-01

    Plasma betaine concentrations and urinary betaine excretions have high test-retest reliability. Abnormal betaine excretion is common in diabetes. We aimed to confirm the individuality of plasma betaine and urinary betaine excretion in an overweight population with type 2 diabetes and compare this with the individuality of other osmolytes, one-carbon metabolites and trimethylamine-N-oxide (TMAO), thus assessing their potential usefulness as disease markers. Urine and plasma were collected from overweight subjects with type 2 diabetes at four time points over a two-year period. We measured the concentrations of the osmolytes: betaine, glycerophosphorylcholine (GPC) and taurine, as well as TMAO, and the one-carbon metabolites, N,N-dimethylglycine (DMG) and free choline. Samples were measured using tandem mass spectrometry (LC-MS/MS). Betaine showed a high degree of individuality (or test-retest reliability) in the plasma (index of individuality = 0.52) and urine (index of individuality = 0.45). Betaine in the plasma had positive and negative log-normal reference change values (RCVs) of 54% and -35%, respectively. The other osmolytes, taurine and GPC were more variable in the plasma of individuals compared to the urine. DMG and choline showed high individuality in the plasma and urine. TMAO was highly variable in the plasma and urine (log-normal RCVs ranging from 403% to -80% in plasma). Betaine is highly individual in overweight people with diabetes. Betaine, its metabolite DMG, and precursor choline showed more reliability than the osmolytes, GPC and taurine. The low reliability of TMAO suggests that a single TMAO measurement has low diagnostic value. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. Examination of iodine status in the German population: an example for methodological pitfalls of the current approach of iodine status assessment.

    PubMed

    Johner, S A; Thamm, M; Schmitz, R; Remer, T

    2016-04-01

    Preliminary iodine concentration (UIC) measurements in spot urines of the representative German adult study DEGS indicated a severe worsening of iodine status compared to previous results in German children (KiGGS study). Therefore, we aimed to evaluate adult iodine status in detail and to investigate the impact of hydration status on UIC. UIC and creatinine concentrations were measured in 6978 spot urines from the German nationwide DEGS study (2008-2011). Twenty-four-hour iodine excretions (24-h UIE) were estimated by relating iodine/creatinine ratios to age- and sex-specific 24-h creatinine reference values. Urine osmolality was measured in two subsamples of spot urines (n = 100 each) to determine the impact of hydration status on UIC. In DEGS, median UIC was 69 µg/L in men and 54 µg/L in women, lying clearly below the WHO cutoff for iodine sufficiency (100 µg/L). Estimated median 24-h UIE was 113 µg/day, accompanied by 32 % of DEGS adults, lying below the estimated average requirement (EAR) for iodine. Comparative analysis with the KiGGS data (>14,000 spot urines of children; median UIC 117 µg/L) revealed a comparable percentage

  13. The influence of storage time and temperature on the measurement of serum, plasma and urine osmolality.

    PubMed

    Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen

    2016-07-01

    Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.

  14. Urinary Volatile Organic Compounds for the Detection of Prostate Cancer

    PubMed Central

    Khalid, Tanzeela; Aggio, Raphael; White, Paul; De Lacy Costello, Ben; Persad, Raj; Al-Kateb, Huda; Jones, Peter; Probert, Chris S.; Ratcliffe, Norman

    2015-01-01

    The aim of this work was to investigate volatile organic compounds (VOCs) emanating from urine samples to determine whether they can be used to classify samples into those from prostate cancer and non-cancer groups. Participants were men referred for a trans-rectal ultrasound-guided prostate biopsy because of an elevated prostate specific antigen (PSA) level or abnormal findings on digital rectal examination. Urine samples were collected from patients with prostate cancer (n = 59) and cancer-free controls (n = 43), on the day of their biopsy, prior to their procedure. VOCs from the headspace of basified urine samples were extracted using solid-phase micro-extraction and analysed by gas chromatography/mass spectrometry. Classifiers were developed using Random Forest (RF) and Linear Discriminant Analysis (LDA) classification techniques. PSA alone had an accuracy of 62–64% in these samples. A model based on 4 VOCs, 2,6-dimethyl-7-octen-2-ol, pentanal, 3-octanone, and 2-octanone, was marginally more accurate 63–65%. When combined, PSA level and these four VOCs had mean accuracies of 74% and 65%, using RF and LDA, respectively. With repeated double cross-validation, the mean accuracies fell to 71% and 65%, using RF and LDA, respectively. Results from VOC profiling of urine headspace are encouraging and suggest that there are other metabolomic avenues worth exploring which could help improve the stratification of men at risk of prostate cancer. This study also adds to our knowledge on the profile of compounds found in basified urine, from controls and cancer patients, which is useful information for future studies comparing the urine from patients with other disease states. PMID:26599280

  15. Validation of a multi-analyte HPLC-DAD method for determination of uric acid, creatinine, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid and 2-methylhippuric acid in human urine.

    PubMed

    Remane, Daniela; Grunwald, Soeren; Hoeke, Henrike; Mueller, Andrea; Roeder, Stefan; von Bergen, Martin; Wissenbach, Dirk K

    2015-08-15

    During the last decades exposure sciences and epidemiological studies attracts more attention to unravel the mechanisms for the development of chronic diseases. According to this an existing HPLC-DAD method for determination of creatinine in urine samples was expended for seven analytes and validated. Creatinine, uric acid, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid, and 2-methylhippuric acid were separated by gradient elution (formate buffer/methanol) using an Eclipse Plus C18 Rapid Resolution column (4.6mm×100mm). No interfering signals were detected in mobile phase. After injection of blank urine samples signals for the endogenous compounds but no interferences were detected. All analytes were linear in the selected calibration range and a non weighted calibration model was chosen. Bias, intra-day and inter-day precision for all analytes were below 20% for quality control (QC) low and below 10% for QC medium and high. The limits of quantification in mobile phase were in line with reported reference values but had to be adjusted in urine for homovanillic acid (45mg/L), niacinamide 58.5(mg/L), and indole-3-acetic acid (63mg/L). Comparison of creatinine data obtained by the existing method with those of the developed method showing differences from -120mg/L to +110mg/L with a mean of differences of 29.0mg/L for 50 authentic urine samples. Analyzing 50 authentic urine samples, uric acid, creatinine, hippuric acid, and 2-methylhippuric acid were detected in (nearly) all samples. However, homovanillic acid was detected in 40%, niacinamide in 4% and indole-3-acetic acid was never detected within the selected samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Prediction of long-term prognosis by heteroplasmy levels of the m.3243A>G mutation in patients with the mitochondrial encephalomyopathy, lactic acidosis and stroke-like episodes syndrome.

    PubMed

    Fayssoil, A; Laforêt, P; Bougouin, W; Jardel, C; Lombès, A; Bécane, H M; Berber, N; Stojkovic, T; Béhin, A; Eymard, B; Duboc, D; Wahbi, K

    2017-02-01

    Our aim was to determine the prognostic value of urine and blood heteroplasmy in patients with the m.3243A>G mutation. Adults with the m.3243A>G mutation referred to our institution between January 2000 and May 2014 were retrospectively included. The relationship between their baseline clinical characteristics, their mutation load in urine and blood, and major adverse events (MAEs) during follow-up, defined as medical complications requiring a hospitalization or complicated by death, was studied. Of the 43 patients (age 45.6 ± 13.3 years) included in the study, 36 patients were symptomatic, including nine with evidence of focal brain involvement, and seven were asymptomatic. Over a 5.5 ± 4.0 year mean follow-up duration, 14 patients (33%) developed MAEs. Patients with MAEs had a higher mutation load than others in urine (60.1% ± 13.8% vs. 40.6% ± 26.2%, P = 0.01) and in blood (26.9% ± 18.4% vs. 16.0% ± 12.1%, P = 0.03). Optimal cutoff values for the prediction of MAEs were 45% for urine and 35% for blood. In multivariate analysis, mutation load in urine ≥45% [odds ratio 25.3; 95% confidence interval (CI) 1.1-567.8; P = 0.04], left ventricular hypertrophy (odds ratio 16.7; 95% CI 1.3- 222.5; P = 0.03) and seizures (odds ratio 48.3; 95% CI 2.5-933; P = 0.01) were associated with MAEs. Patients with the m.3243A>G mutation are at high risk of MAEs, which can be independently predicted by mutation load in urine ≥45%, a personal history of seizures, and left ventricular hypertrophy. © 2016 EAN.

  17. Deep Sequencing of Urinary RNAs for Bladder Cancer Molecular Diagnostics.

    PubMed

    Sin, Mandy L Y; Mach, Kathleen E; Sinha, Rahul; Wu, Fan; Trivedi, Dharati R; Altobelli, Emanuela; Jensen, Kristin C; Sahoo, Debashis; Lu, Ying; Liao, Joseph C

    2017-07-15

    Purpose: The majority of bladder cancer patients present with localized disease and are managed by transurethral resection. However, the high rate of recurrence necessitates lifetime cystoscopic surveillance. Developing a sensitive and specific urine-based test would significantly improve bladder cancer screening, detection, and surveillance. Experimental Design: RNA-seq was used for biomarker discovery to directly assess the gene expression profile of exfoliated urothelial cells in urine derived from bladder cancer patients ( n = 13) and controls ( n = 10). Eight bladder cancer specific and 3 reference genes identified by RNA-seq were quantitated by qPCR in a training cohort of 102 urine samples. A diagnostic model based on the training cohort was constructed using multiple logistic regression. The model was further validated in an independent cohort of 101 urines. Results: A total of 418 genes were found to be differentially expressed between bladder cancer and controls. Validation of a subset of these genes was used to construct an equation for computing a probability of bladder cancer score (P BC ) based on expression of three markers ( ROBO1, WNT5A , and CDC42BPB ). Setting P BC = 0.45 as the cutoff for a positive test, urine testing using the three-marker panel had overall 88% sensitivity and 92% specificity in the training cohort. The accuracy of the three-marker panel in the independent validation cohort yielded an AUC of 0.87 and overall 83% sensitivity and 89% specificity. Conclusions: Urine-based molecular diagnostics using this three-marker signature could provide a valuable adjunct to cystoscopy and may lead to a reduction of unnecessary procedures for bladder cancer diagnosis. Clin Cancer Res; 23(14); 3700-10. ©2017 AACR . ©2017 American Association for Cancer Research.

  18. Mass spectrometric detection of peginesatide in human urine in doping control analysis.

    PubMed

    Möller, Ines; Thomas, Andreas; Delahaut, Philippe; Geyer, Hans; Schänzer, Wilhelm; Thevis, Mario

    2012-11-01

    Erythropoiesis-stimulating agents (ESAs) have frequently been confessed to be illicitly used in elite sports due to their endurance enhancing effects. Recently, peginesatide, the first representative of a new generation of ESAs, referred to as Erythropoietin (EPO)-mimetic peptides, obtained approval in the USA under the trade name Omontys(®) for the treatment of anaemic patients. Lacking sequence homology with EPO, it consists of a pegylated homodimeric peptide of approximately 45 kDa, and thus, specific approaches for the determination of peginesatide in blood were developed as conventional detection assays for EPO do not allow for the analysis of the EPO-mimetic peptides. However, as urine specimens are the most frequently provided doping control samples and pharmacokinetic studies conducted in rats and monkeys revealed the excretion of the pegylated peptide into urine, a detection method for peginesatide in urine would be desirable. A mass spectrometric assay in human urine was developed consisting of protein precipitation with acetonitrile followed by proteolytic digestion after the removal of the acetonitrile fraction under reduced pressure. Purification and concentration of the resulting proteotypic target peptide was accomplished by means of solid-phase extraction on strong cation-exchange resin prior to liquid chromatographic-tandem mass spectrometric analysis. Method validation was performed for qualitative purposes and demonstrated specificity, precision, linearity as well as sufficient sensitivity (limit of detection: 0.5 ng/ml) while proof-of-concept for the applicability of the assay for the determination of peginesatide in authentic urine samples was obtained by analyzing animal in vivo specimens collected after a single i.v. administration of peginesatide over a period of 4 days. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Urine biomarkers of kidney injury among adolescents in Nicaragua, a region affected by an epidemic of chronic kidney disease of unknown aetiology

    PubMed Central

    Ramírez-Rubio, Oriana; Amador, Juan José; Kaufman, James S.; Weiner, Daniel E.; Parikh, Chirag R.; Khan, Usman; McClean, Michael D.; Laws, Rebecca L.; López-Pilarte, Damaris; Friedman, David J.; Kupferman, Joseph; Brooks, Daniel R.

    2016-01-01

    Background An epidemic of chronic kidney disease (CKD) of non-traditional aetiology has been recently recognized by health authorities as a public health priority in Central America. Previous studies have identified strenuous manual work, agricultural activities and residence at low altitude as potential risk factors; however, the aetiology remains unknown. Because individuals are frequently diagnosed with CKD in early adulthood, we measured biomarkers of kidney injury among adolescents in different regions of Nicaragua to assess whether kidney damage might be initiated during childhood. Methods Participants include 200 adolescents aged 12–18 years with no prior work history from four different schools in Nicaragua. The location of the school served as a proxy for environmental exposures and geographic locations were selected to represent a range of factors that have been associated with CKD in adults (e.g. altitude, primary industry and CKD mortality rates). Questionnaires, urine dipsticks and kidney injury biomarkers [interleukin-18, N-acetyl-d-glucosaminidase (NAG), neutrophil gelatinase-associated lipocalin (NGAL) and albumin–creatinine ratio] were assessed. Biomarker concentrations were compared by school using linear regression models. Results Protein (3.5%) and glucose (1%) in urine measured by dipstick were rare and did not differ by school. Urine biomarkers of tubular kidney damage, particularly NGAL and NAG, showed higher concentrations in those schools and regions within Nicaragua that were defined a priori as having increased CKD risk. Painful urination was a frequent self-reported symptom. Conclusions Although interpretation of these urine biomarkers is limited because of the lack of population reference values, results suggest the possibility of early kidney damage prior to occupational exposures in these adolescents. PMID:26311057

  20. A novel method for the quantitation of gingerol glucuronides in human plasma or urine based on stable isotope dilution assays.

    PubMed

    Schoenknecht, Carola; Andersen, Gaby; Schieberle, Peter

    2016-11-15

    The bio-active compounds of ginger (Zingiber officinale Roscoe), the gingerols, are gaining considerable attention due to their numerous beneficial health effects. In order to elucidate the physiological relevance of the ascribed effects their bioavailability has to be determined taking their metabolization into account. To quantitate in vivo generated [6]-, [8]- and [10]-gingerol glucuronides in human plasma and urine after ginger tea consumption, a simultaneous and direct liquid chromatography-tandem mass spectrometry method based on stable isotope dilution assays was established and validated. The respective references as well as the isotopically labeled substances were synthesized and characterized by mass spectrometry and NMR. Selective isolation of gingerol glucuronides from human plasma and urine by a mixed-phase anion-exchange SPE method led to recovery rates between 80.8 and 98.2%. LC-MS/MS analyses in selected reaction monitoring modus enabled a highly sensitive quantitation of gingerol glucuronides with LoQs between 3.9-9.8nmol/L in plasma and 39.3-161.1nmol/L in urine. The method precision in plasma and urine varied in the range±15%, whereas the intra-day accuracy in plasma and urine showed values between 78 and 122%. The developed method was then applied to a pilot study in which two volunteers consumed one liter ginger tea. Pharmacokinetic parameters like the maximum concentration (c max ), the time to reach c max (t max ), area under the curve (AUC), elimination rate constant (k el ) and elimination half-life (t 1/2 ) were calculated from the concentration-time curve of each gingerol glucuronide. The obtained results will enable more detailed investigation of gingerol glucuronides as bioactives in their physiologically relevant concentrations. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Long-term therapeutic efficacy of photo-selective vaporization of prostate

    NASA Astrophysics Data System (ADS)

    Arum, Carl-Jørgen; Muller, Camilla; Romundstad, Pal; Stokkan, Inger; Mjønes, Jan

    2010-02-01

    OBJECTIVES: We evaluated the long term therapeutic efficacy of 80 watt photo-selective vaporization of the prostate (PVP) in patients suffering from lower urinary tract symptoms (LUTS) secondary to prostatic obstruction. MATERIAL & METHODS: 150 unselected patients at the average age 73 (range 51-92) and a mean American Society of Anesthesiologists score of 2.4 (median 2.0), of whom 33% were medicated with acetylsalicylic acid and 5% were anticoagulated with warfarin. Inclusion/exclusion criteria were the same as for TUR-P at our institution. First patient was operated March 2004 and yearly follow-up of all patients has been attempted for 5 years. Follow-up variables have included yearly creatinine, PSA, IPSS, ØOL, post-void residual urin and maximum/average urine flow rate. RESULTS: At 12 and 24 months postoperatively, the following parameters were significantly (p<0.001) improved: trans-rectal ultrasound, international prostate symptom score, quality of life score, post-void residual urine volume, flow max/average, opening pressure, pressure @ flow-max, and micturition resistance. At 48 and 60 months creatinine, PSA, IPSS, ØOL, post-void residual urin and maximum/average urine flow rates were still significantly (p<0.001) improved compared to pre-operative values. CONCLUSION: Up to 5 year follow-up reveals that 80 watt PVP provides significant and stable symptom relief as well as objective improvement in residual urine and flowmetric outcomes.

  2. The influence of freezer storage of urine samples on the BONN-Risk-Index for calcium oxalate crystallization.

    PubMed

    Laube, Norbert; Zimmermann, Diana J

    2004-01-01

    This study was performed to quantify the effect of a 1-week freezer storage of urine on its calcium oxalate crystallization risk. Calcium oxalate is the most common urinary stone material observed in urolithiasis patients in western and affluent countries. The BONN-Risk-Index of calcium oxalate crystallization risk in human urine is determined from a crystallization experiment performed on untreated native urine samples. We tested the influence of a 1-week freezing on the BONN-Risk-Index value as well as the effect of the sample freezing on the urinary osmolality. In vitro crystallization experiments in 49 native urine samples from stone-forming and non-stone forming individuals were performed in order to determine their calcium oxalate crystallization risk according to the BONN-Risk-Index approach. Comparison of the results derived from original sample investigations with those obtained from the thawed aliquots by statistical evaluation shows that i) no significant deviation from linearity between both results exists and ii) both results are identical by statistical means. This is valid for both, the BONN-Risk-Index and the osmolality data. The differences in the BONN-Risk-Index results of both procedures of BONN-Risk-Index determination, however, exceed the clinically acceptable difference. Thus, determination of the urinary calcium oxalate crystallization risk from thawed urine samples cannot be recommended.

  3. Evaluation of LSSP-PCR for identification of Leptospira spp. in urine samples of cattle with clinical suspicion of leptospirosis.

    PubMed

    Bomfim, Maria Rosa Quaresma; Koury, Matilde Cota

    2006-12-20

    We evaluated the use of low-stringency single specific primer PCR (LSSP-PCR) for genetically typing Leptospira directly from urine samples of cattle with clinical suspicion of leptospirosis. Urine samples obtained from 40 cattle with clinical suspicion of leptospirosis were amplified by specific PCR using the following primers: Internal 1/Internal 2 and G1/G2. The internal primers were designed from the gene sequence of the outer membrane lipoprotein Lip32 from Leptospira kirschneri, strain RM52. The PCR products were amplified with these two pairs of primers, which had approximately 497 and 285bp, respectively, and were subsequently used as a template for LSSP-PCR analysis. The genetic signatures from the leptospires which were present in the urine samples allowed us to make a preliminary identification of the leptospires by comparing the LSSP-PCR profiles obtained directly from urine samples with those from reference leptospires. The LSSP-PCR profiles obtained with the Internal 1 primer or with the G1 primer allowed the grouping of the leptospires into serogroups. LSSP-PCR was found to be a useful and sensitive approach capable of identifying leptospires directly from biological samples without the need for prior bacterial isolation. In conclusion, the LSSP-PCR technique may still be helpful in discriminating serogroups of Leptospira from different animal reservoirs, since the early identification of carrier animals and information on the shedding state are crucial to prevent the spread of leptospiral infection to other animals and humans.

  4. Drinking-Water Disinfection By-products and Semen Quality: A Cross-Sectional Study in China

    PubMed Central

    Zeng, Qiang; Wang, Yi-Xin; Xie, Shao-Hua; Xu, Liang; Chen, Yong-Zhe; Li, Min; Yue, Jing; Li, Yu-Feng; Liu, Ai-Lin

    2014-01-01

    Background: Exposure to disinfection by-products (DBPs) has been demonstrated to impair male reproductive health in animals, but human evidence is limited and inconsistent. Objective: We examined the association between exposure to drinking-water DBPs and semen quality in a Chinese population. Methods: We recruited 2,009 men seeking semen analysis from the Reproductive Center of Tongji Hospital in Wuhan, China, between April 2011 and May 2012. Each man provided a semen sample and a urine sample. Semen samples were analyzed for sperm concentration, sperm motility, and sperm count. As a biomarker of exposure to drinking-water DBPs, trichloroacetic acid (TCAA) was measured in the urine samples. Results: The mean (median) urinary TCAA concentration was 9.58 (7.97) μg/L (interquartile range, 6.01–10.96 μg/L). Compared with men with urine TCAA in the lowest quartile, increased adjusted odds ratios (ORs) were estimated for below-reference sperm concentration in men with TCAA in the second and fourth quartiles (OR = 1.79; 95% CI: 1.19, 2.69 and OR = 1.51; 95% CI: 0.98, 2.31, respectively), for below-reference sperm motility in men with TCAA in the second and third quartiles (OR = 1.46; 95% CI: 1.12, 1.90 and OR = 1.30; 95% CI: 1.00, 1.70, respectively), and for below-reference sperm count in men with TCAA in the second quartile (OR 1.62; 95% CI: 1.04, 2.55). Nonmonotonic associations with TCAA quartiles were also estimated for semen parameters modeled as continuous outcomes, although significant negative associations were estimated for all quartiles above the reference level for sperm motility. Conclusion: Our findings suggest that exposure to drinking-water DBPs may contribute to decreased semen quality in humans. Citation: Zeng Q, Wang YX, Xie SH, Xu L, Chen YZ, Li M, Yue J, Li YF, Liu AL, Lu WQ. 2014. Drinking-water disinfection by-products and semen quality: a cross-sectional study in China. Environ Health Perspect 122:741–746; http://dx.doi.org/10.1289/ehp.1307067 PMID:24695319

  5. Multicenter Evaluation of the AMPLICOR and Automated COBAS AMPLICOR CT/NG Tests for Detection of Chlamydia trachomatis

    PubMed Central

    Van Der Pol, Barbara; Quinn, Thomas C.; Gaydos, Charlotte A.; Crotchfelt, Kimberly; Schachter, Julius; Moncada, Jeanne; Jungkind, D.; Martin, David H.; Turner, Buffy; Peyton, Cynthia; Jones, Robert B.

    2000-01-01

    The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for the ability to detect Chlamydia trachomatis infections. Test performance compared to that of culture was evaluated for 2,236 matched endocervical swab and urine specimens obtained from women and for 1,940 matched urethral swab and urine specimens obtained from men. Culture-negative, PCR-positive specimens that tested positive in a direct fluorescent-antibody test or in a confirmatory PCR test for an alternative target sequence were resolved as true positives. The overall prevalences of chlamydia were 2.4% in women and 7.2% in men. The COBAS AMPLICOR and AMPLICOR formats yielded concordant results for 98.1% of the specimens. With the infected patient as the reference standard, the resolved sensitivities of COBAS AMPLICOR were 89.7% for endocervical swab specimens, 89.2% for female urine specimens, 88.6% for male urethral swab specimens, and 90.3% for male urine specimens. When results were analyzed as if only a single test had been performed on a single specimen type, the resolved sensitivity was always higher. The resolved specificities of PCR were 99.4% for endocervical swab specimens, 99.0% for female urine specimens, 98.7% for male urethral swab specimens, and 98.4% for male urine specimens. The internal control revealed that 2.4% of the specimens were inhibitory when initially tested. Nevertheless, valid results were obtained for 98.6% of the specimens because 59.1% of the inhibitory specimens were not inhibitory when a second aliquot was tested. The COBAS AMPLICOR and AMPLICOR CT/NG tests for C. trachomatis exhibited equally high sensitivity and specificity with both urogenital swab and urine specimens and thus are well suited for screening for C. trachomatis infection. PMID:10699004

  6. Coupled brain and urine spectroscopy - in vivo metabolomic characterization of HMG-CoA lyase deficiency in 5 patients.

    PubMed

    Roland, Dominique; Jissendi-Tchofo, Patrice; Briand, Gilbert; Vamecq, Joseph; Fontaine, Monique; Ultré, Vincent; Acquaviva-Bourdain, Cécile; Mention, Karine; Dobbelaere, Dries

    2017-06-01

    3-Hydroxy-3-Methylglutaryl-Coenzyme A (HMG-CoA) lyase deficiency is a rare inborn error of leucine metabolism and ketogenesis. Despite recurrent hypoglycemia and metabolic decompensations, most patients have a good clinical and neurological outcome contrasting with abnormal brain magnetic resonance imaging (MRI) signals and consistent abnormal brain proton magnetic resonance spectroscopy ( 1 H-MRS) metabolite peaks. Identifying these metabolites could provide surrogate markers of the disease and improve understanding of MRI-clinical discrepancy and follow-up of affected patients. Urine samples, brain MRI and 1 H-MRS in 5 patients with HMG-CoA lyase deficiency (4 boys and 1 girl aged from 25days to 10years) were, for each patient, obtained on the same day. Brain and urine spectroscopy were performed at the same pH by studying urine at pH 7.4. Due to pH-induced modifications in chemical shifts and because reference 1 H NMR spectra are obtained at pH 2.5, spectroscopy of normal urine added with the suspected metabolite was further performed at this pH to validate the correct identification of compounds. Mild to extended abnormal white matter MRI signals were observed in all cases. Brain spectroscopy abnormal peaks at 0.8-1.1ppm, 1.2-1.4ppm and 2.4ppm were also detected by urine spectroscopy at pH 7.4. Taking into account pH-induced changes in chemical shifts, brain abnormal peaks in patients were formally identified to be those of 3-hydroxyisovaleric, 3-methylglutaconic, 3-methylglutaric and 3-hydroxy-3-methylglutaric acids. 3-Methylglutaric, 3-hydroxyisovaleric and 3-hydroxy-3-methylglutaric acids identified on urine 1 H-NMR spectra of 5 patients with HMG-CoA lyase deficiency are responsible for the cerebral spectroscopy signature seen in these patients, validating their local involvement in brain and putative contribution to brain neuropathology. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. PVC flooring is related to human uptake of phthalates in infants.

    PubMed

    Carlstedt, F; Jönsson, B A G; Bornehag, C-G

    2013-02-01

    Polyvinyl chloride (PVC) flooring material contains phthalates, and it has been shown that such materials are important sources for phthalates in indoor dust. Phthalates are suspected endocrine-disrupting chemicals (EDCs). Consecutive infants between 2 and 6 months old and their mothers were invited. A questionnaire about indoor environmental factors and family lifestyle was used. Urinary metabolites of the phthalates diethyl phthalate (DEP), dibutyl phthalate (DBP), butylbenzyl phthalate (BBzP), and dietylhexyl phthalate (DEHP) were measured in the urine of the children. Of 209 invited children, 110 (52%) participated. Urine samples were obtained from 83 of these. Urine levels of the BBzP metabolite monobenzyl phthalate (MBzP) was significantly higher in infants with PVC flooring in their bedrooms (P < 0.007) and related to the body area of the infant. Levels of the DEHP metabolites MEHHP (P < 0.01) and MEOHP (P < 0.04) were higher in the 2-month-old infants who were not exclusively breast-fed when compared with breast-fed children. The findings indicate that the use of soft PVC as flooring material may increase the human uptake of phthalates in infants. Urinary levels of phthalate metabolites during early life are associated with the use of PVC flooring in the bedroom, body area, and the use of infant formula. This study shows that the uptake of phthalates is not only related to oral uptake from, for example, food but also to environmental factors such as building materials. This new information should be considered when designing indoor environment, especially for children. © 2012 John Wiley & Sons A/S.

  8. Graphene oxide for solid-phase extraction of bioactive phenolic acids.

    PubMed

    Hou, Xiudan; Wang, Xusheng; Sun, Yingxin; Wang, Licheng; Guo, Yong

    2017-05-01

    A solid-phase extraction (SPE) method for the efficient analysis of trace phenolic acids (PAs, caffeic acid, ferulic acid, protocatechuic acid, cinnamic acid) in urine was established. In this work, a graphene oxide (GO) coating was grafted onto pure silica to be investigated as SPE material. The prepared GO surface had a layered and wrinkled structure that was rough and well organized, which could provide more open adsorption sites. Owing to its hydrophilicity and polarity, GO showed higher extraction efficiency toward PAs than reduced GO did, in agreement with the theoretical calculation results performed by Gaussian 09 software. The adsorption mechanism of PAs on GO@Sil was also investigated through static state and kinetic state adsorption experiments, which showed a monolayer surface adsorption. Extraction capacity of the as-prepared material was optimized using the response surface methodology. Under the optimized conditions, the as-established method provided wide linearity range (2-50 μg L -1 for protocatechuic acid and 1-50 μg L -1 for caffeic acid, ferulic acid, and cinnamic acid) and low limits of detection (0.25-1 μg L -1 ). Finally, the established method was applied for the analysis of urine from two healthy volunteers. The results indicate that the prepared material is a practical, cost-effective medium for the extraction and determination of phenolic acids in complex matrices. Graphical Abstract A graphene oxide coating was grafted onto pure silica as the SPE material for the extraction of phenolic acids in urines and the extraction mechanism was also mainly investigated.

  9. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study.

    PubMed

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda

    2018-01-01

    Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.

  10. Suture material in bladder surgery: a comparison of polydioxanone, polyglactin, and chromic catgut.

    PubMed

    Stewart, D W; Buffington, P J; Wacksman, J

    1990-06-01

    A comparison of polydioxanone, polyglactin, and chromic catgut suture was performed in 120 rat bladders studying propensity for infection, degree of inflammation, calculogenic potential, changes in urine pH, and suture absorption. None of the sutures predisposed to infection and there was wide variability but no correlation in urine pH. Although initially the polydioxanone incited a greater inflammatory response, by six months all three sutures were similar. The absorption of polydioxanone was slower than chromic catgut suture, but similar to the absorption of polyglactin. There was no significant difference in calculogenic potential between the suture materials tested over a six-month period. Based on this study in rats, polydioxanone suture would appear to be equal to catgut and polyglactin suture in bladder surgery.

  11. Determination of total concentration of chemically labeled metabolites as a means of metabolome sample normalization and sample loading optimization in mass spectrometry-based metabolomics.

    PubMed

    Wu, Yiman; Li, Liang

    2012-12-18

    For mass spectrometry (MS)-based metabolomics, it is important to use the same amount of starting materials from each sample to compare the metabolome changes in two or more comparative samples. Unfortunately, for biological samples, the total amount or concentration of metabolites is difficult to determine. In this work, we report a general approach of determining the total concentration of metabolites based on the use of chemical labeling to attach a UV absorbent to the metabolites to be analyzed, followed by rapid step-gradient liquid chromatography (LC) UV detection of the labeled metabolites. It is shown that quantification of the total labeled analytes in a biological sample facilitates the preparation of an appropriate amount of starting materials for MS analysis as well as the optimization of the sample loading amount to a mass spectrometer for achieving optimal detectability. As an example, dansylation chemistry was used to label the amine- and phenol-containing metabolites in human urine samples. LC-UV quantification of the labeled metabolites could be optimally performed at the detection wavelength of 338 nm. A calibration curve established from the analysis of a mixture of 17 labeled amino acid standards was found to have the same slope as that from the analysis of the labeled urinary metabolites, suggesting that the labeled amino acid standard calibration curve could be used to determine the total concentration of the labeled urinary metabolites. A workflow incorporating this LC-UV metabolite quantification strategy was then developed in which all individual urine samples were first labeled with (12)C-dansylation and the concentration of each sample was determined by LC-UV. The volumes of urine samples taken for producing the pooled urine standard were adjusted to ensure an equal amount of labeled urine metabolites from each sample was used for the pooling. The pooled urine standard was then labeled with (13)C-dansylation. Equal amounts of the (12)C-labeled individual sample and the (13)C-labeled pooled urine standard were mixed for LC-MS analysis. This way of concentration normalization among different samples with varying concentrations of total metabolites was found to be critical for generating reliable metabolome profiles for comparison.

  12. Urine Markers Do Not Predict Biopsy Findings or Presence of Bladder Ulcers in Interstitial Cystitis/Painful Bladder Syndrome

    PubMed Central

    Erickson, Deborah R.; Tomaszewski, John E.; Kunselman, Allen R.; Stetter, Christina M.; Peters, Kenneth M.; Rovner, Eric S.; Demers, Laurence M.; Wheeler, Marcia A.; Keay, Susan K.

    2009-01-01

    Purpose To test for associations between urine markers, bladder biopsy features and bladder ulcers in interstitial cystitis/painful bladder syndrome (IC/PBS). Materials and Methods Subjects were 72 patients with IC/PBS undergoing bladder distention and biopsy. Urine was collected before the procedure. Urine marker levels were correlated with biopsy and cystoscopic findings. Patients with no previous IC/PBS treatments (n=47) were analyzed separately from previously treated patients (n=25). Results For untreated patients, urine IL-6 and cGMP were associated with urothelial EGF receptor staining (for IL-6 r=0.29, 95% CI (0.07, 0.51), p=0.01; for cGMP r=0.34, 95% CI (0.13, 0.55), p=0.002). Urine IL-8 was negatively associated with urothelial HB-EGF staining (r=-0.34, 95% CI (-0.55, -0.12), p=0.002) and positively associated with lamina propria mast cell count (r=0.29, 95% CI (0.06, 0.52), p=0.01). The latter association also was seen in treated patients (r=0.46, 95% CI (0.20, 0.73), p<0.001). None of the urine markers was significantly different for ulcer vs. nonulcer patients. All of the ulcer patients had extensive inflammation on bladder biopsy: severe mononuclear cell infiltration, moderate or strong IL-6 staining in the urothelium and lamina propria, and LCA staining in >10% of the lamina propria. However, these features also were seen in 24-76% of the nonulcer patients. Conclusions Overall, urine markers did not associate robustly with biopsy findings. The strongest association was a positive association between urine IL-8 levels and bladder mast cell count. Ulcer patients consistently had bladder inflammation, but the cystoscopic finding of ulcers was not a sensitive indicator of inflammation on bladder biopsy. PMID:18353383

  13. Drug testing data from the 2007 Pan American Games: delta13C values of urinary androsterone, etiocholanolone and androstanediols determined by GC/C/IRMS.

    PubMed

    Aguilera, Rodrigo; Chapman, Thomas E; Pereira, Henrique; Oliveira, Giselle C; Illanes, Renata P; Fernandes, Telma F; Azevedo, Débora A; Neto, Francisco Aquino

    2009-07-01

    The main purpose of this article is to show the application of the CG/C/IRMS in real time during competition in the steroid confirmation analysis. For this reason, this paper summarizes the results obtained from the doping control analysis during the period of the 2007 Pan American Games held in Rio de Janeiro, Brazil. Approximately 5600 athletes from 42 different countries competed in the games. Testing was performed in accordance to World Anti-Doping Agency (WADA) technical note for prohibited substances. This paper reports data where abnormal urinary steroid profiles, have been found with the screening procedures. One 8 mL urine sample was used for the analysis of five steroid metabolites with two separate analyses by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Urine samples were submitted to GC/C/IRMS for confirmation analysis to determine the (13)C/(12)C ratio of selected steroids. Fifty-seven urine samples were analyzed by GC/C/IRMS and the delta(13)C values ( per thousand) of androsterone, etiocholanolone, 5beta-androstane-3alpha, 17beta-diol (5beta-diol), 5alpha-androstane-3alpha, 17beta-diol (5alpha-diol) and 5beta-pregnane-3alpha, 20alpha-diol (5beta-pdiol), the endogenous reference compound are presented. One urine sample with a testosterone/epitestosterone (T/E) ratio of 4.7 was confirmed to be positive of doping by GC/C/IRMS analysis. The delta values of 5beta-diol and 5alpha-diol were 3.8 and 10.8, respectively, compared to the endogenous reference compound 5beta-pdiol, which exceeded the WADA limit of 3 per thousand. The results obtained by CG/C/IRMS confirmation analyses, in suspicious samples, were conclusive in deciding whether or not a doping steroid violation had occurred.

  14. A fluid-structure interaction (FSI)-based numerical investigation of peristalsis in an obstructed human ureter.

    PubMed

    Takaddus, Ahmed Tasnub; Gautam, Prashanta; Chandy, Abhilash J

    2018-05-08

    Urine moves from the kidney to the bladder through the ureter. A series of compression waves facilitates this transport. Due to the highly concentrated mineral deposits in urine, stones are formed in the kidney and travel down through the urinary tract. While passing, a larger stone can get stuck and cause severe damage to ureter wall. Also, stones in the ureter obstructing the urine flow can cause pain and backflow of urine which in turn might require surgical intervention. The current study develops a 2D axisymmetric numerical model to gain an understanding of the ureter obstruction and its effects on the flow, which are critical in assessing the different treatment options. Transient computational analysis involving a two-way fully coupled fluid-structure interaction with the arbitrary Lagrangian-Eulerian method between the ureteral wall and urine flow is conducted with an obstruction in the ureter. The ureter wall is modeled as an anisotropic hyperelastic material, data of which, is based on biaxial tests on human ureter from previous literature, while the incompressible Navier-Stokes equations are solved to calculate urine flow. A finite element-based monolithic solver is used for the simulations here. The obstruction is placed in the fluid domain as a circular stone at the proximal part of the ureter. One of the objectives of this study is to quantify the effect of the ureteral obstruction. A sharp jump in pressure gradient and wall shear stress, as well as retrograde urine flow, is observed as a result of the obstruction. Copyright © 2018 John Wiley & Sons, Ltd.

  15. 16 CFR 305.19 - Promotional material displayed or distributed at point of sale.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT... concerning a covered product that is a showerhead, faucet, water closet, or urinal shall clearly and conspicuously include in such printed material the product's water use, expressed in gallons and liters per...

  16. Multi-trace element levels and arsenic speciation in urine of e-waste recycling workers from Agbogbloshie, Accra in Ghana.

    PubMed

    Asante, Kwadwo Ansong; Agusa, Tetsuro; Biney, Charles Augustus; Agyekum, William Atuobi; Bello, Mohammed; Otsuka, Masanari; Itai, Takaaki; Takahashi, Shin; Tanabe, Shinsuke

    2012-05-01

    To understand human contamination by multi-trace elements (TEs) in electrical and electronic waste (e-waste) recycling site at Agbogbloshie, Accra in Ghana, this study analyzed TEs and As speciation in urine of e-waste recycling workers. Concentrations of Fe, Sb, and Pb in urine of e-waste recycling workers were significantly higher than those of reference sites after consideration of interaction by age, indicating that the recycling workers are exposed to these TEs through the recycling activity. Urinary As concentration was relatively high, although the level in drinking water was quite low. Speciation analysis of As in human urine revealed that arsenobetaine and dimethylarsinic acid were the predominant As species and concentrations of both species were positively correlated with total As concentration as well as between each other. These results suggest that such compounds may be derived from the same source, probably fish and shellfish and greatly influence As exposure levels. To our knowledge, this is the first study on human contamination resulting from the primitive recycling of e-waste in Ghana. This study will contribute to the knowledge about human exposure to trace elements from an e-waste site in a less industrialized region so far scantly covered in the literature. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Simultaneous LC/MS/MS determination of thiols and disulfides in urine samples based on differential labeling with ferrocene-based maleimides.

    PubMed

    Seiwert, Bettina; Karst, Uwe

    2007-09-15

    A method for the simultaneous determination of a series of thiols and disulfides in urine samples has been developed based on the sequential labeling of free and bound thiol functionalities with two ferrocene-based maleimide reagents. The sample is first exposed to N-(2-ferroceneethyl)maleimide, thus leading to the derivatization of free thiol groups in the sample. After quantitative reaction and subsequent reduction of the disulfide-bound thiols by tris(2-carboxyethyl)phosphine, the newly formed thiol functionalities are reacted with ferrocenecarboxylic acid-(2-maleimidoyl)ethylamide. The reaction products are determined by LC/MS/MS in the multiple reaction mode, and precursor ion scan as well as neutral loss scan is applied to detect unknown further thiols. The method was successfully applied to the analysis of free and disulfide-bound thiols in urine samples. Limits of detection are 30 to 110 nM, and the linear range comprises two decades of concentration, thus covering the relevant concentration range of thiols in urine samples. The thiol and disulfide concentrations were referred to the creatinine content to compensate for different sample volumes. As some calibration standards for the disulfides are not commercially available, they were synthesized in an electrochemical flow-through cell. This allowed the synthesis of hetero- and homodimeric disulfides.

  18. [Relative bioavailability of various quinidine preparations in man after a single oral dose].

    PubMed

    Terhaag, B; Gieszinger, U

    1982-12-01

    The bioavailability of quinidine sulfate in different preparations (quinidine in capsules as reference; Quinidine longo; Qunidine longo with either quinidine in the cover or in the nucleus, Quinidine Duriles) was investigated in 8 healthy volunteers in plasma and urine in a crossover design. There are no differences in the AUCo infinitey and in the eliminated amount in urine after infinit time. Quinidine longo possesses two maxima at 0.8 +/- 0.1 h and at 3.1 +/- 0.2 h. These maxima are caused by the liberation from the cover and the nucleus. The quotients of retardation (RD = ratio of the duration at 1/2 Cpmax, RC = ratio of 1/2 Cpmax, quinidine sulfate as reference) is calculated for Quinidine longo: RD = 1.42 +/- 0.14, RC = 0.75 +/- 0,05 and for Quinidine Duriles: RD = 1.79 +/- 0.21, RC = 0.52 +/- 0.07. The effect of retardation of Quinidine longo is not so much as that of Quinidine Duriles. However there are no statistic differences for RD in contrast to RC between these two retard-preparations.

  19. Predicting Patients with Inadequate 24- or 48-Hour Urine Collections at Time of Metabolic Stone Evaluation.

    PubMed

    McGuire, Barry B; Bhanji, Yasin; Sharma, Vidit; Frainey, Brendan T; McClean, Megan; Dong, Caroline; Rimar, Kalen; Perry, Kent T; Nadler, Robert B

    2015-06-01

    We aimed to understand the characteristics of patients who are less likely to submit adequate urine collections at metabolic stone evaluation. Inadequate urine collection was defined using two definitions: (1) Reference ranges for 24-hour creatinine/kilogram (Cr/24) and (2) discrepancy in total 24-hour urine Cr between 24-hour urine collections. There were 1502 patients with ≥1 kidney stone between 1998 and 2014 who performed a 24- or 48-hour urine collection at Northwestern Memorial Hospital and who were identified retrospectively. Multivariate analysis was performed to analyze predictor variables for adequate urine collection. A total of 2852 urine collections were analyzed. Mean age for males was 54.4 years (range 17-86), and for females was 50.2 years (range 8-90). One patient in the study was younger than 17 years old. (1) Analysis based on the Cr 24/kg definition: There were 50.7% of patients who supplied an inadequate sample. Females were nearly 50% less likely to supply an adequate sample compared with men, P<0.001. Diabetes (odds ratio [OR] 1.42 [1.04-1.94], P=0.026) and vitamin D supplementation (OR 0.64 [0.43-0.95], P=0.028) predicted receiving an adequate/inadequate sample, respectively. (2) Analysis based on differences between total urinary Cr: The model was stratified based on percentage differences between samples up to 50%. At 10%, 20%, 30%, 40%, and 50% differences, inadequate collections were achieved in 82.8%, 66.9%, 51.7%, 38.5%, and 26.4% of patients, respectively. Statistical significance was observed based on differences of ≥40%, and this was defined as the threshold for an inadequate sample. Female sex (OR 0.73 [0.54-0.98], P=0.037) predicted supplying inadequate samples. Adequate collections were more likely to be received on a Sunday (OR 1.6 [1.03-2.58], P=0.038) and by sedentary workers (OR 2.3 [1.12-4.72], P=0.023). Urine collections from patients during metabolic evaluation for nephrolithiasis may be considered inadequate based on two commonly used clinical definitions. This may have therapeutic or economic ramifications and the propensity for females to supply inadequate samples should be investigated further.

  20. Investigation of magnetic nanoparticles for the rapid extraction and assay of alpha-emitting radionuclides from urine: Demonstration of a novel radiobioassay method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Hara, Matthew J.; Carter, Jennifer C.; Maclellan, Jay A.

    2011-08-01

    In the event of an accidental or intentional release of radionuclides into a populated area, three things must occur in a timely manner: food and drinking water supplies must be determined to be safe to eat / drink, civilians and/or military personnel must be surveyed to ensure that they do not have external contamination, and they must be screened to ensure that significant ingestion or inhalation of radionuclides has not occurred (this paper is concerned with the latter). In the event of such a disaster, the volume of radiobioassays to be performed would be tremendous. If the event released significantmore » levels of β- or α-emitting radionuclides, in vivo assays would be ineffective. Therefore, highly efficient and rapid analytical methods for radionuclide detection from submitted spot urine samples (≤ 50 mL) would be required. At present, the quantitative determination of α-emitting radionuclides from urine samples is highly labor intensive, and requires significant sample preparation and analysis time. Sorbent materials that provide effective collection and enable rapid assay could significantly streamline the radioanalytical process. We have demonstrated the use of paramagnetic nanoparticles as a novel class of extracting media for four α-emitting radionuclides of concern (Po, Ra, Am, and U) from chemically unmodified and pH 2 human urine. Herein the initial experimental sorption results are presented along with a novel method that utilizes paramagnetic nanoparticles for the extraction of radionuclides from unmodified human urine followed by the magnetic field-induced collection of the particles for subsequent α-counting-source preparation. Additionally, we construct a versatile human dose model that determines the detector count times required to estimate internal human dose at specific protective action thresholds. The model provides a means to assess a method’s detection capabilities and use fundamental health physics parameters and actual experimental data as core variables. The modeling shows that with effective sorbent materials, rapid screening for internalized α-emitters is possible from a 50 mL spot urine sample volume collected within one week of exposure/intake.« less

  1. In vitro results with special plastics for biodegradable endoureteral stents.

    PubMed

    Schlick, R W; Planz, K

    1998-10-01

    Internal ureteral stents are widely used in urologic practice for temporary urinary diversion, but all double-J catheters to date exhibit the same disadvantage; that is, they have to be removed endoscopically, necessitating further intervention. We tested different materials (designated G100X-15xLB and G100X-20xLB) to develop a biodegradable (biodissolvable) endoureteral stent that can be held in place without functional loss yet could be dissolved by changing the environment. The principle of the biochemical background is based on the physiological milieu of the urine. The plastics tested are stable in acidic and dissolve in alkaline conditions. In a first step, specimens of two polymers were placed in artificial urine of different pH over a period of 60 days and monitored for integrity (solution trial). In a second step, artificial urine was set in motion (744 mL/24 hours) an infusion pump (Volumed microVP 5000; Fresenius AG, Bad Homburg vdH, Germany) through an infusion set in which a 30-cm piece of the materials to test had been placed (ureter model). Below the inserted specimen, the lumen of the infusion tube was minimized to make obstruction by fragments more possible. In the solution trial, all specimens remained stable under physiologic conditions (pH 5.2) over a period of at least 30 days. The specimens dissolved completely when the pH was adjusted to an alkaline one (pH 7.9). In the ureter model, with pH values of 7.9, all specimens were decomposed after 20 hours, and no occlusion of the model occurred. Using acidic artificial urine, the specimens remained stable with a smooth consistent surface. The dissolution was not a standard chemical one; the materials broke into microscopically small pieces, with fragments of G100X-20xLB being smaller than those of G100X-15xLB. Our first in vitro results show that the tested materials are suitable for further development of biodissolvable endoureteral stents, dissolution of which can be steered by changing the urinary pH.

  2. [Peculiarities of detection of 4-nitro-3-(trifluoromethyl)-aniline in the biological material].

    PubMed

    Shormanov, V K; Andreeva, Yu V; Omel'chenko, V A

    2016-01-01

    The objective of the present work was to study peculiarities of detection of 4-nitro-3-(trifluoromethyl)-aniline in the biological material with the use of TLC, GC-MS, and electron spectrophotometry. We have proposed the rationale for the application of acetone as an insulating agent for the extraction of 4-nitro-3-(trifluoromethyl)-aniline from the cadaveric hepatic tissue and biological fluids. It was shown that this compound is possible to separate from endogenous biomaterials on the silicagel L column (40/100 mcm). The results of the quantitative evaluation of different amounts of 4-nitro-3-(trifluoromethyl)-aniline in the cadaveric hepatic tissue, blood, plasma, and urine are presented. The proposed method makes it possible to determine a minimum of 0.12 mg of 4-nitro-3-(trifluoromethyl)-aniline in 100 g of the biological material (cadaveric hepatic tissue), 0.09 mg in 100 g of blood, 0.06 mg and 0.05 mg in 100 u of plasma and urine respectively.

  3. Creatine and guanidinoacetate reference values in a French population.

    PubMed

    Joncquel-Chevalier Curt, Marie; Cheillan, David; Briand, Gilbert; Salomons, Gajja S; Mention-Mulliez, Karine; Dobbelaere, Dries; Cuisset, Jean-Marie; Lion-François, Laurence; Des Portes, Vincent; Chabli, Allel; Valayannopoulos, Vassili; Benoist, Jean-François; Pinard, Jean-Marc; Simard, Gilles; Douay, Olivier; Deiva, Kumaran; Tardieu, Marc; Afenjar, Alexandra; Héron, Delphine; Rivier, François; Chabrol, Brigitte; Prieur, Fabienne; Cartault, François; Pitelet, Gaëlle; Goldenberg, Alice; Bekri, Soumeya; Gerard, Marion; Delorme, Richard; Porchet, Nicole; Vianey-Saban, Christine; Vamecq, Joseph

    2013-11-01

    Creatine and guanidinoacetate are biomarkers of creatine metabolism. Their assays in body fluids may be used for detecting patients with primary creatine deficiency disorders (PCDD), a class of inherited diseases. Their laboratory values in blood and urine may vary with age, requiring that reference normal values are given within the age range. Despite the long known role of creatine for muscle physiology, muscle signs are not necessarily the major complaint expressed by PCDD patients. These disorders drastically affect brain function inducing, in patients, intellectual disability, autistic behavior and other neurological signs (delays in speech and language, epilepsy, ataxia, dystonia and choreoathetosis), being a common feature the drop in brain creatine content. For this reason, screening of PCDD patients has been repeatedly carried out in populations with neurological signs. This report is aimed at providing reference laboratory values and related age ranges found for a large scale population of patients with neurological signs (more than 6 thousand patients) previously serving as a background population for screening French patients with PCDD. These reference laboratory values and age ranges compare rather favorably with literature values for healthy populations. Some differences are also observed, and female participants are discriminated from male participants as regards to urine but not blood values including creatine on creatinine ratio and guanidinoacetate on creatinine ratio values. Such gender differences were previously observed in healthy populations; they might be explained by literature differential effects of testosterone and estrogen in adolescents and adults, and by estrogen effects in prepubertal age on SLC6A8 function. Finally, though they were acquired on a population with neurological signs, the present data might reasonably serve as reference laboratory values in any future medical study exploring abnormalities of creatine metabolism and transport. © 2013 Elsevier Inc. All rights reserved.

  4. Human biomonitoring reference values for some non-persistent chemicals in blood and urine derived from the Canadian Health Measures Survey 2009-2013.

    PubMed

    Khoury, Cheryl; Werry, Kate; Haines, Douglas; Walker, Mike; Malowany, Morie

    2018-05-01

    The Canadian Health Measures Survey collects nationally representative human biomonitoring data on a suite of chemicals and their metabolites, including many non-persistent chemicals. Data has been collected on non-persistent chemicals, including acrylamide, chlorophenols, environmental phenols and triclocarban, organophosphate insecticides, phthalates, polycyclic aromatic hydrocarbon, pyrethroid insecticides, and volatile organic compounds from 2009 to 2013. Using a systematic approach building on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry, we derive human biomonitoring reference values (RV 95 s) for these classes of non-persistent chemicals in blood and urine for the general Canadian population. RV 95 s were derived for biomarkers of non-persistent chemicals with widespread detection in Canadians (>66% detection rate). Samples with urinary creatinine levels outside the recommended range of 0.3-3.0 μg/L were excluded. Reference populations were constructed by applying smoking and fasting as exclusion criteria where appropriate. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for sub-populations in cases where partitioning was deemed necessary. Reference values were derived for 40 biomarkers and represent the first set of RV 95 s for non-persistent chemicals in the general Canadian population. These values provide a measure of the upper margin of background exposure in the general population and can be compared against individual and population human biomonitoring data. RV 95 s can be used to by public health officials to identify individuals with high exposures, and by risk assessors and risk managers to identify atypical exposures or subpopulations with elevated exposures. Crown Copyright © 2018. Published by Elsevier GmbH. All rights reserved.

  5. Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas

    PubMed Central

    Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick Mm; Leeflang, Mariska Mg

    2015-01-01

    Background Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. Objectives To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. Search methods We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. Selection criteria We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Data collection and analysis Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). Main results We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopy Compared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21). When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assay Compared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Authors' conclusions Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy. The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy. Plain Language Summary How well do point-of-care tests detect Schistosoma infections in people living inendemic areas? Schistosomiasis, also known as bilharzia, is a parasitic disease common in the tropical and subtropics. Point-of-care tests and urine reagent strip tests are quicker and easier to use than microscopy. We estimate how well these point-of-care tests are able to detect schistosomiasis infections compared with microscopy. We searched for studies published in any language up to 30 June 2014, and we considered the study’s risk of providing biased results. What do the results say? We included 90 studies involving almost 200,000 people, with 88 of these studies carried out in Africa in field settings. Study design and conduct were poorly reported against current expectations. Based on our statistical model, we found: • Among the urine strips for detecting urinary schistosomiasis, the strips for detecting blood were better than those detecting protein or white cells (sensitivity and specificity for blood 75% and 87%; for protein 61% and 82%; and for white cells 58% and 61%, respectively). • For urinary schistosomiasis, the parasite antigen test performance was worse (sensitivity, 39% and specificity, 78%) than urine strips for detecting blood. • For intestinal schistosomiasis, the parasite antigen urine test, detected many infections identified by microscopy but wrongly labelled many uninfected people as sick (sensitivity, 89% and specificity, 55%). What are the consequences of using these tests? If we take 1000 people, of which 410 have urinary schistosomiasis on microscopy testing, then using the strip detecting blood in the urine would misclassify 77 uninfected people as infected, and thus may receive unnecessary treatment; and it would wrongly classify 102 infected people as uninfected, who thus may not receive treatment. If we take 1000 people, of which 360 have intestinal schistosomiasis on microscopy testing, then the antigen test would misclassify 288 uninfected people as infected. These people may be given unnecessary treatment. This test also would wrongly classify 40 infected people as uninfected who thus may not receive treatment. Conclusion of review For urinary schistosomiasis, the urine strip for detecting blood leads to some infected people being missed and some non-infected people being diagnosed with the condition, but is better than the protein or white cell tests. The parasite antigen test is not accurate. For intestinal schistosomiasis, the parasite antigen urine test can wrongly classify many uninfected people as infected. PMID:25758180

  6. [Detection of urinary organic acids by gradual titration of pH 2,0-7,4. Significance for the assessment of the litho-protective characteristic of the examined urine].

    PubMed

    Leskovar, P; Hartung, R; Hropot, M; Huber, H; Friedl, H; Wellnhofer, E; Steffek, D; Schöninger, R

    1981-08-01

    The role of organic acids in urine is not sufficiently known until today. From our detailed in vitro studies it can be concluded that some of them are highly efficacious in the inhibition of Ca-oxalate and Ca-phosphate crystal growth. Moreover, some of them showed, as acids and as salts, a strong lytic effect on stone-forming crystals and native stone-material. By the oral application to rats, concentrations preventing any precipitation out of meta- and instable Ca-oxalate solutions could be achieved. The renal excretion was controlled by the stepwise titration of preacidified urinary samples from pH 2.0 to 7.4 and the lithoprotective character of urine estimated by the Ca2+-binding capacity.

  7. Organic chemistry in space

    NASA Technical Reports Server (NTRS)

    Johnson, R. D.

    1977-01-01

    Organic cosmochemistry, organic materials in space exploration, and biochemistry of man in space are briefly surveyed. A model of Jupiter's atmosphere is considered, and the search for organic molecules in the solar system and in interstellar space is discussed. Materials and analytical techniques relevant to space exploration are indicated, and the blood and urine analyses performed on Skylab are described.

  8. The effects of intracrystalline and surface-bound proteins on the attachment of calcium oxalate monohydrate crystals to renal cells in undiluted human urine

    PubMed Central

    Grover, Phulwinder K.; Thurgood, Lauren A.; Wang, Tingting; Ryall, Rosemary L.

    2010-01-01

    Objective To compare the binding to Madin-Darby canine kidney (MDCK)-II cells of: (i) inorganic calcium oxalate monohydrate (iCOM) crystals and COM crystals precipitated from urine containing different concentrations of protein; and (ii) urinary COM crystals containing intracrystalline and intracrystalline + surface-bound protein. Materials and methods Urinary COM crystals were generated in sieved (sCOM), centrifuged and filtered (cfCOM), and ultrafiltered (ufCOM) portions of a pooled human urine and their adhesion to MDCK-II cells was compared using six different ultrafiltered urine samples as the binding medium. Crystal matrix extract (CME) was prepared by demineralizing calcium oxalate crystals precipitated from human urine and used to prepare COM crystals with intracrystalline, and intracrystalline + surface-bound CME at protein concentrations of 0, 0.05, 0.1, 0.5 and 5.0 mg/L. The amount of protein associated with the crystals was qualitatively assessed by sodium dodecyl sulphate-polyacrylamide gel electrophoresis and Western blotting, using prothrombin fragment 1 (PTF1) as a marker. Protein concentration was determined in sieved, centrifuged and filtered, and ultrafiltered fractions of 10 additional urine samples. Results The median crystal attachment in the six urine types decreased in the order iCOM > ufCOM > cfCOM = sCOM, in inverse proportion to the concentration of protein in the solution or urine from which they were precipitated. sCOM and cfCOM crystals bound ≈□ 23% less than iCOM crystals. The attachment of COM crystals generated in the presence of increasing concentrations of CME proteins was unaffected up to a concentration of 5 mg/L, but binding of crystals containing the same concentrations of intracrystalline + surface-bound proteins decreased proportionally at protein concentrations from 0 to 5.0 mg/L. Conclusion Inorganic COM crystals bind significantly more strongly to MDCK-II cells than urinary crystals precipitated from sieved, centrifuged and filtered, and ultrafiltered urine, and binding affinity is inversely related to the concentration of protein in the urine in which they are formed. While both intracrystalline and superficial CME proteins reduce the attachment of COM crystals to MDCK-II cells, those located on the crystal surface have a greater influence than those incarcerated within the mineral bulk. Future cell–crystal interaction studies should use urinary crystals and be performed in human urine. PMID:19694711

  9. Measurement of daily sodium excretion in patients with chronic kidney disease; special reference to the difference between the amount measured from 24 h collected urine sample and the estimated amount from a spot urine.

    PubMed

    Amano, Hoichi; Kobayashi, Seiji; Terawaki, Hiroyuki; Ogura, Makoto; Kawaguchi, Yoshindo; Yokoo, Takashi

    2018-11-01

    It is important to grasp a patient's daily sodium intake in the management of chronic kidney disease, as sodium intake is widely recommended at 6 g/day or less. There are multiple equations widely known for estimating the daily sodium excretion from a spot urine sample, but these are aimed at healthy people. There are few reports that validate equations in patients with chronic kidney disease. The purpose of this study is to evaluate whether the amount of measured daily sodium excretion from a sample collected for 24-h urine (24HU) is equal to that of using an equation from a spot urine sample (SU) in patients with chronic kidney disease. One hundred sixty-two patients with chronic kidney disease from Kanagawa Prefecture Shiomidai Hospital, Japan and the Jikei University Kashiwa Hospital, Japan participated in the study. Daily sodium excretion was measured from 24HU and compared with it from SU by using the formula according to Tanaka et al. Sodium excretion by 24HU was 2744 mg/day and estimating daily sodium excretion from SU was 3315 mg/day. The coefficient of determination was 0.17 (p < .001) in multivariate regression analysis. The coefficient of determination was extremely low. Thus, there is a considerable difference between the amount of sodium excretion calculated from a 24HU and that from a SU in patients with chronic kidney disease.

  10. Povidone iodine sclerotherapy for treatment of idiopathic renal hematuria in two dogs.

    PubMed

    Adelman, Lauren B; Bartges, Joseph; Whittemore, Jacqueline C

    2017-01-15

    CASE DESCRIPTION A 6-year-old spayed female Great Pyrenees (dog 1) and a 2-year-old spayed female German Shepherd Dog (dog 2) were evaluated because of gross hematuria of 5 and 2 months' duration, respectively. CLINICAL FINDINGS In both dogs, coagulation times were within reference limits, results of aerobic bacterial culture of urine samples were negative, echogenic debris could be seen within the urinary bladder ultrasonographically, and hematuric urine could be seen exiting the right ureterovesicular junction, with grossly normal urine exiting the left ureterovesicular junction, during cystoscopy. A diagnosis of idiopathic renal hematuria was made in both dogs. TREATMENT AND OUTCOME Both dogs underwent retrograde ureteropyelography, unilateral povidone iodine sclerotherapy, and ureteral stent placement. The right ureter was occluded with a ureteropelvic junction balloon catheter, and a 5% povidone iodine solution was infused into the renal pelvis 3 times. A double-pigtail ureteral stent was then placed. Both dogs recovered without complications, with cessation of gross hematuria within 12 hours. Cystoscopic removal of the ureteral stent was performed in dog 1 after 4 months; at that time, the urine sediment contained 5 to 10 RBCs/hpf. In dog 2, urine sediment contained 50 to 75 RBCs/hpf 2 weeks after sclerotherapy, with continued resolution of gross hematuria 8 weeks after sclerotherapy. The owners declined removal of the stent in dog 2. CLINICAL RELEVANCE Findings suggested that povidone iodine sclerotherapy may be an effective renal-sparing treatment for idiopathic renal hematuria in dogs. Further evaluation with longer follow-up times is warranted.

  11. Analysis of Four Automated Urinalysis Systems Compared to Reference Methods.

    PubMed

    Bartosova, Kamila; Kubicek, Zdenek; Franekova, Janka; Louzensky, Gustav; Lavrikova, Petra; Jabor, Antonin

    2016-11-01

    The aim of this study was to compare four automated urinalysis systems: the Iris iQ200 Sprint (Iris Diagnostics, U.S.A.) combined with the Arkray AUTION MAX AX 4030, Iris + AUTION, Arkray AU 4050 (Arkray Global Business, Inc., Japan), Dirui FUS 2000 (Dirui Industrial Co., P.R.C.), and Menarini sediMAX (Menarini, Italy). Urine concentrations of protein and glucose (Iris, Dirui) were compared using reference quantitative analysis on an Abbott Architect c16000. Leukocytes, erythrocytes, epithelia, and casts (Iris, Arkray, Diuri, Menarini) were compared to urine sediment under reference light microscopy, Leica DM2000 (Leica Microsystems GmbH, Germany) with calibrated FastRead plates (Biosigma S.r.l., Italy), using both native and stained preparations. Total protein and glucose levels were measured using the Iris + AUTION system with borderline trueness, while the Dirui analysis revealed worse performances for the protein and glucose measurements. True classifications of leukocytes and erythrocytes were above 85% and 72%, respectively. Kappa statistics revealed a nearly perfect evaluation of leukocytes for all tested systems; the erythrocyte evaluation was nearly perfect for the Iris, Dirui and Arkray analyzers and substantial for the Menarini analyzer. The epithelia identification was connected to high false negativity (above 15%) in the Iris, Arkray, and Menarini analyses. False-negative casts were above 70% for all tested systems. The use of automated urinalysis demonstrated some weaknesses and should be checked by experienced laboratory staff using light microscopy.

  12. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--HANDLING QUALITY CONTROL SAMPLES IN THE FIELD (RTI/ACS-AP-209-090)

    EPA Science Inventory

    This protocol describes how quality control samples should be handled in the field, and was designed as a quick reference source for the field staff. The protocol describes quality control samples for air-VOCs, air-particles, water samples, house dust, soil, urine, blood, hair, a...

  13. Next-generation sequencing of urine specimens: A novel platform for genomic analysis in patients with non-muscle-invasive urothelial carcinoma treated with bacille Calmette-Guérin.

    PubMed

    Scott, Sasinya N; Ostrovnaya, Irina; Lin, Caroline M; Bouvier, Nancy; Bochner, Bernard H; Iyer, Gopakumar; Solit, David; Berger, Michael F; Lin, Oscar

    2017-06-01

    Biopsies from patients with high-risk (HR) non-muscle-invasive urothelial carcinoma (NMIUC), especially flat urothelial carcinoma in situ, frequently contain scant diagnostic material or denuded mucosa only, and this precludes further extensive genomic analysis. This study evaluated the use of next-generation sequencing (NGS) analysis of urine cytology material from patients with HR NMIUC in an attempt to identify genetic alterations that might correlate with clinical features and responses to bacille Calmette-Guérin (BCG) treatment. Forty-one cytology slides from patients with HR NMIUC treated with intravesical BCG were selected for this study. Histological confirmation was available for all cases. The specimens were subjected to NGS analysis with a customized targeted exome capture assay composed of 341 genes. In this cohort, genomic alterations were successfully identified in all cytology samples. Mutations were detected down to a 2% allele frequency and chromosomal rearrangements including copy number alterations and gene fusions were identified. The most frequently altered genes included telomerase reverse transcriptase (TERT), tumor protein 53 (TP53), Erb-B2 receptor tyrosine kinase 2 (ERBB2), and chromatin remodeling genes such as lysine demethylase 6A (KDM6A) and AT-rich interaction domain 1A (ARID1A). For patients with matched tumor tissue, cytology specimens revealed all mutations detected in tissue as well as additional mutations, and this suggested that urine might more effectively capture the full genetic heterogeneity of disease than an individual cystectomy. Alterations in multiple genes correlated with clinical and histopathological features, including responses to BCG treatment, flat architecture versus papillary architecture, and smoking history. Urine specimens can replace tissue as a substrate for NGS analysis of HR NMIUC. Several genomic alterations identified in urine specimens might be associated with histological features and clinical characteristics. Cancer Cytopathol 2017;125:416-26. © 2017 American Cancer Society. © 2017 American Cancer Society.

  14. An Acute Ocfentanil Fatality: A Case Report with Postmortem Concentrations.

    PubMed

    Dussy, F E; Hangartner, S; Hamberg, C; Berchtold, C; Scherer, U; Schlotterbeck, G; Wyler, D; Briellmann, T A

    2016-11-01

    A 24-year-old man known to consume illegal drugs was found dead in his apartment. A reclosable plastic zipper bag containing several hundred milligrams of a brown powder was found close to the dead body and the first assumption of the investigators was death due to heroin intoxication. Therefore, a legal autopsy was ordered. The following toxicological analysis revealed ocfentanil in urine and in the brown powder. Four different approaches for the determination of the ocfentanil concentrations in peripheral whole blood are described. Enrichment of ocfentanil from the powder was realized. With this reference, it was possible to determine the ocfentanil concentration in the seized powder to be 0.91%. Concentrations of ocfentanil were also determined in the sampled body fluids using the standard addition procedure. In peripheral blood 9.1 µg/L, in heart blood 27.9 µg/L and in urine 480 µg/L were measured. In addition, the antidepressant citalopram, the neuroleptic quetiapine and cannabinoids were found in urine and subsequently quantified in peripheral blood. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Diabetes insipidus as a rare cause of acute cognitive impairment in multiple sclerosis.

    PubMed

    Tiedje, V; Schlamann, M; Führer, D; Moeller, L C

    2013-10-01

    Multiple sclerosis (MS) is a complex neurodegenerative disease presenting with a diversity of clinical symptoms including palsy and cognitive impairment. We present a 59-year-old woman with a history of secondary progressive MS since 1987, who was referred to our department because of recent onset of confusion and polydipsia. Initial lab tests showed mildly elevated serum sodium levels and low urine osmolality. Under water deprivation, diuresis and low urine osmolality persisted and serum sodium levels rose above 150 mmol/l. Oral desmopressin resulted in normalisation of serum sodium as well as urine osmolarity, confirming a diagnosis of central diabetes insipidus. As drug-induced diabetes could be excluded, pituitary magnetic resonance imaging (MRI) was performed. A demyelinating lesion was detected in the hypothalamus. The patient was started on oral desmopressin treatment (0.2 mg/day). Fluid intake and serum sodium levels have since remained normal. In summary, we report the rare case of a patient presenting with diabetes insipidus due to progressive MS. Diabetes insipidus should be considered in MS patients who develop new onset of polydipsia.

  16. Multiplexed targeted mass spectrometry assays for prostate cancer-associated urinary proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Tujin; Quek, Sue-Ing; Gao, Yuqian

    Biomarkers for effective early diagnosis and prognosis of prostate cancer are still lacking. Multiplexed assays for cancer-associated proteins could be useful for identifying biomarkers for cancer detection and stratification. Herein, we report the development of sensitive targeted mass spectrometry assays for simultaneous quantification of 10 prostate cancer-associated proteins in urine. The diagnostic utility of these markers was evaluated with an initial cohort of 20 clinical urine samples. Individual marker concentration was normalized against the measured urinary prostate-specific antigen level as a reference of prostate-specific secretion. The areas under the receiver-operating characteristic curves for the 10 proteins ranged from 0.75 formore » CXCL14 to 0.87 for CEACAM5. Furthermore, MMP9 level was found to be significantly higher in patients with high Gleason scores, suggesting a potential of MMP9 as a marker for risk level assessment. Taken together, our work illustrated the feasibility of accurate multiplexed measurements of low-abundance cancer-associated proteins in urine and provided a viable path forward for preclinical verification of candidate biomarkers for prostate cancer.« less

  17. Pharmacokinetics of colistin and colistimethate sodium after a single 80-mg intravenous dose of CMS in young healthy volunteers.

    PubMed

    Couet, W; Grégoire, N; Gobin, P; Saulnier, P J; Frasca, D; Marchand, S; Mimoz, O

    2011-06-01

    Colistin pharmacokinetics (PK) was investigated in young healthy volunteers after a 1-h infusion of 80 mg (1 million international units (MIU)) of the prodrug colistin methanesulfonate (CMS). Concentration levels of CMS and colistin were determined in plasma and urine using a new chromatographic assay and analyzed simultaneously with a population approach after correcting the urine-related data for postexcretion hydrolysis of CMS into colistin. CMS and colistin have low volumes of distribution (14.0 and 12.4 liters, respectively), consistent with distribution being restricted to extracellular fluid. CMS is mainly excreted unchanged in urine (70% on average), with a typical renal clearance estimated at 103 ml/min-close to the glomerular filtration rate. Colistin elimination is essentially extrarenal, given that its renal clearance is 1.9 ml/min, consistent with extensive reabsorption. Colistin elimination is not limited by the formation rate because its half-life (3 h) is longer than that of CMS. The values of these pharmacokinetic parameters will serve as reference points for future comparisons with patients' data.

  18. Lipid peroxidation in workers exposed to hexavalent chromium.

    PubMed

    Huang, Y L; Chen, C Y; Sheu, J Y; Chuang, I C; Pan, J H; Lin, T H

    1999-02-26

    The aim of this study was to investigate whether exposure to hexavalent chromium induces lipid peroxidation in human. This study involved 25 chrome-plating factory workers and a reference group of 28 control subjects. The whole-blood and urinary chromium concentrations were determined by graphite furnace atomic absorption spectrophotometry. Malondialdehyde (MDA), the product of lipid peroxidation, was determined by high-performance liquid chromatography, and the activities of protective enzymes were measured by ultraviolet-visible spectrophotometry. In the chrome-plating workers, the mean concentrations of chromium in blood and urine were 5.98 microg/L and 5.25 microg/g creatinine, respectively; the mean concentrations of MDA in blood and urine were 1.7 micromol/L and 2.24 micromol/g creatinine. The concentrations of both chromium and MDA in blood and urine were significantly higher in the chromium-exposed workers. The activities of superoxide dismutase (SOD), glutathione peroxidase (GPX), and catalase (CAT) were not markedly different between control and exposed workers. Data suggest that MDA may be used as a biomarker for occupational chromium exposure. Antioxidant enzymic activities are not a suitable marker for chromium exposure.

  19. The metabolism of the anti-inflammatory drug eterylate in rat, dog and man.

    PubMed

    Wood, S G; John, B A; Chasseaud, L F; Johnstone, I; Biggs, S R; Hawkins, D R; Priego, J G; Darragh, A; Lambe, R F

    1983-12-01

    Oral doses of 14C-eterylate were well absorbed by rat and man and excreted mainly in the urine (94% dose by rat in three days and 91% by man in five days). Oral doses to dogs were excreted in similar proportions in both the urine and faeces, although faecal 14C was probably derived in part, from biliary-excreted material. Peak plasma 14C and drug concn. were generally reached between one and three hours after oral doses. In humans, only two metabolites, salicylic acid and 4-acetamido-phenoxyacetic acid, were detected in plasma. The latter was cleared more rapidly than the former and hence plasma salicyclate concn. reached a peak (10.9 and 19.8 micrograms/ml in Subjects 1 and 2, respectively) and initially declined with a half-life of about two-three hours. Plasma 4-acetamidophenoxyacetic acid concn. reached a peak (4.3, 10.0 micrograms/ml, respectively) and declined with a half-life of about one hour. Tissue concn. of 14C were generally greater in dogs than in rats. Highest conc. occurred at three hours in dogs and at one hour in rats. Apart from those in the liver and kidneys, tissue concn. were lower than those in the corresponding plasma. Unchanged drug was not detected in urine or plasma of any species and was rapidly metabolized in human plasma. The major 14C components in human urine were identified as salicyluric acid and 4-acetamidophenoxyacetic acid; minor metabolites were salicylic acid, gentisic acid and paracetamol. These metabolites were also detected in rat urine albeit in different proportions to those in human urine. Dog urine contained less of these metabolites and a major proportion of the 14C was associated with relatively non-polar components. Although salicylic acid and 4-acetamidophenoxyacetic acid were the only major circulating metabolites in man and rat, dog plasma also contained the non-polar urine metabolites.

  20. Human biomonitoring reference values for metals and trace elements in blood and urine derived from the Canadian Health Measures Survey 2007-2013.

    PubMed

    Saravanabhavan, Gurusankar; Werry, Kate; Walker, Mike; Haines, Douglas; Malowany, Morie; Khoury, Cheryl

    2017-03-01

    Human biomonitoring reference values are statistical estimates that indicate the upper margin of background exposure to a given chemical at a given time. Nationally representative human biomonitoring data on 176 chemicals, including several metals and trace elements, are available in Canada from 2007 to 2013 through the Canadian Health Measures Survey (CHMS). In this work, we used a systematic approach based on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry to derive reference values (RV 95 s) for metals and trace elements. These RV 95 s were derived for blood and urine matrices in the general Canadian population based on the latest biomonitoring data from the CHMS. Biomarkers were chosen based on specific selection criteria, including widespread detection in Canadians (≥66% detection rate). Reference populations were created for each biomarker by applying appropriate exclusion criteria. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for the sub-populations in cases where partitioning was deemed necessary. The RV 95 s for metals and trace elements in blood ranged from 0.18μg/L for cadmium in young children aged 3-5 years to 7900μg/L for zinc in males aged 20-79 years. In the case of urinary biomarkers, the RV 95 s ranged from 0.17μg/L for antimony in the total population aged 3-79 years to 1400mg/L for fluoride in adults aged 20-79 years. These RV 95 s represent the first set of reference values for metals and trace elements in the general Canadian population. We compare the RV 95 s from other countries where available and discuss factors that could influence such comparisons. Copyright © 2016 The Authors. Published by Elsevier GmbH.. All rights reserved.

  1. Clenbuterol storage stability in the bovine urine and liver samples used for European official control in the azores islands (portugal).

    PubMed

    Pinheiro, Isabel; Jesuino, Bruno; Barbosa, Jorge; Ferreira, Humberto; Ramos, Fernando; Matos, José; da Silveira, Maria Irene Noronha

    2009-02-11

    Clenbuterol is a well-known growth promoter, illegally used in farm animals, especially in cattle. Samples collected for the screening of beta(2)-agonist residues in Portuguese Azores Islands must travel through all the nine islands until they reach Azores Central Laboratory. If any suspicious sample is detected, it must be further transported to the National Reference Laboratory in Lisbon for confirmation. As a consequence of these circumstances, samples are submitted to different transport and storage times, as well as different temperature conditions and in some cases successive freezing and thawing cycles. As clenbuterol is the most detected beta(2)-agonist growth promoter in the Portuguese Residue Monitoring Plan, studies were conducted on the stability of this compound in incurred samples (bovine liver and urine) at +4, -20 and -60 degrees C over time. Samples kept at -20 degrees C were also analyzed over time after successive freezing and thawing cycles. The analyses of clenbuterol over time were performed by gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring (SIM). Clenbuterol in incurred urine and liver samples was significantly stable up to 20 weeks at -20 and -60 degrees C and after, at least, six consecutive freezings and thawings. At +4 degrees C, clenbuterol remained stable, at least until 12 weeks in urine and up to 20 weeks in liver.

  2. Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method to measure creatinine in human urine.

    PubMed

    Fraselle, S; De Cremer, K; Coucke, W; Glorieux, G; Vanmassenhove, J; Schepers, E; Neirynck, N; Van Overmeire, I; Van Loco, J; Van Biesen, W; Vanholder, R

    2015-04-15

    Despite decades of creatinine measurement in biological fluids using a large variety of analytical methods, an accurate determination of this compound remains challenging. Especially with the novel trend to assess biomarkers on large sample sets preserved in biobanks, a simple and fast method that could cope with both a high sample throughput and a low volume of sample is still of interest. In answer to these challenges, a fast and accurate ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to measure creatinine in small volumes of human urine. In this method, urine samples are simply diluted with a basic mobile phase and injected directly under positive electrospray ionization (ESI) conditions, without further purification steps. The combination of an important diluting factor (10(4) times) due to the use of a very sensitive triple quadrupole mass spectrometer (XEVO TQ) and the addition of creatinine-d3 as internal standard completely eliminates matrix effects coming from the urine. The method was validated in-house in 2012 according to the EMA guideline on bioanalytical method validation using Certified Reference samples from the German External Quality Assessment Scheme (G-Equas) proficiency test. All obtained results for accuracy and recovery are within the authorized tolerance ranges defined by G-Equas. The method is linear between 0 and 5 g/L, with LOD and LOQ of 5 × 10(-3) g/L and 10(-2) g/L, respectively. The repeatability (CV(r) = 1.03-2.07%) and intra-laboratory reproducibility (CV(RW) = 1.97-2.40%) satisfy the EMA 2012 guideline. The validated method was firstly applied to perform the German G-Equas proficiency test rounds 51 and 53, in 2013 and 2014, respectively. The obtained results were again all within the accepted tolerance ranges and very close to the reference values defined by the organizers of the proficiency test scheme, demonstrating an excellent accuracy of the developed method. The method was finally applied to measure the creatinine concentration in 210 urine samples, coming from 190 patients with a chronic kidney disease (CKD) and 20 healthy subjects. The obtained creatinine concentrations (ranging from 0.12 g/L up to 3.84 g/L) were compared, by means of a Passing Bablok regression, with the creatinine contents obtained for the same samples measured using a traditional compensated Jaffé method. The UHPLC-MS/MS method described in this paper can be used to normalize the concentration of biomarkers in urine for the extent of dilution. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Blood and urinary levels of metals and metalloids in the general adult population of Northern France: The IMEPOGE study, 2008-2010.

    PubMed

    Nisse, Catherine; Tagne-Fotso, Romuald; Howsam, Mike; Richeval, Camille; Labat, Laurence; Leroyer, Ariane

    2017-04-01

    The assessment of human chemical risks related to occupational or environmental exposure to pollutants requires the use of both accurate exposure indicators and reference values. The objective of this study was to evaluate the blood and urinary levels of various metals and metalloids in a sample of adults aged 20-59 years of the general population of Northern France, a formerly heavily industrialised area that retains some industrial activity. A cross-sectional study was conducted between 2008 and 2010, enrolling 2000 residents of Northern France. The quota method was used to guarantee the representativeness of the participants on a sex, age, social category and smoking status basis, according to the census done by the French National Institute of Statistics and Economic Studies. The levels of 14 metals: aluminium (Al), antimony (Sb), total arsenic (As), beryllium (Be), cadmium (Cd), cobalt (Co), chromium (Cr), mercury (Hg), manganese (Mn), nickel (Ni), lead (Pb), thallium (Tl), vanadium (V) and zinc (Zn) were quantified by ICP-MS in urine and blood samples. A total of 982 men and 1018 women participated, allowing the analysis of 1992 blood and 1910 urine samples. Some metal(loid)s were detected in over 99% of the blood (Cd, Co, Mn, Ni, Pb) and urine (As, Co, Pb, Zn) samples and the remaining metals in 84-99% of the samples, with the exception of blood V (19%), blood Be (57%) and urine Be (58%). Mean blood levels of Pb and Zn were significantly higher in men, and Mn, Co and Cr in women. In urine, mean Pb, Tl and Sb concentrations were significantly higher in men, and Al and Co in women. Current smokers had significantly higher mean levels of blood Cd and Pb and lower blood Co, Mn and Hg. In urine (adjusted on urinary creatinine), the smokers had higher mean levels of Cd, Pb, V and Zn and lower mean levels of As, Co, and Hg. Overall, the mean urinary levels of most metal(loid)s found in the general population of Northern France were higher than those found in the French national survey for the same period except for urinary V. Mean blood lead level was markedly less than that of the French national population. This first biomonitoring survey of a large number of metal(loid)s in the general population of Northern France provides useful information on exposure levels to toxic elements and highlights the specificity of the regional environment. These data could be used, in complement to the national human biomonitoring reference values, for the interpretation of biomonitoring results. Copyright © 2016 Elsevier GmbH. All rights reserved.

  4. Indoor air pollution evaluation with emphasize on HDI and biological assessment of HDA in the polyurethane factories.

    PubMed

    Mirmohammadi, Mirtaghi; Hakimi Ibrahim, M; Ahmad, Anees; Kadir, Mohd Omar Abdul; Mohammadyan, M; Mirashrafi, S B

    2010-06-01

    Today, many raw materials used in factories may have a dangerous effect on the physiological system of workers. One of them which is widely used in the polyurethane factories is diisocyanates. These compounds are widely used in surface coatings, polyurethane foams, adhesives, resins, elastomers, binders, and sealants. Exposure to diisocyanates causes irritation to the skin, mucous membranes, eyes, and respiratory tract. Hexamethylene diamine (HDA) is metabolite of hexamethylene diisocyanate (HDI). It is an excretory material by worker's urine who is exposed to HDI. Around 100 air samples were collected from five defined factories by midget impinger which contained dimethyl sulfoxide absorbent as a solvent and tryptamine as reagent. Samples were analyzed by high-performance liquid chromatography with EC\\UV detector using NIOSH 5522 method of sampling. Also, 50 urine samples collected from workers were also analyzed using William's biological analysis method. The concentration of HDI into all air samples were more than 88 microg/m(3), and they have shown high concentration of pollutant in the workplaces in comparison with NIOSH standard, and all of the workers' urine were contaminated by HDA. The correlation and regression test were used to obtain statistical model for HDI and HDA, which is useful for the prediction of diisocyanates pollution situation in the polyurethane factories.

  5. Electricity and catholyte production from ceramic MFCs treating urine.

    PubMed

    Merino Jimenez, Irene; Greenman, John; Ieropoulos, Ioannis

    2017-01-19

    The use of ceramics as low cost membrane materials for Microbial Fuel Cells (MFCs) has gained increasing interest, due to improved performance levels in terms of power and catholyte production. The catholyte production in ceramic MFCs can be attributed to a combination of water or hydrogen peroxide formation from the oxygen reduction reaction in the cathode, water diffusion and electroosmotic drag through the ion exchange membrane. This study aims to evaluate, for the first time, the effect of ceramic wall/membrane thickness, in terms of power, as well as catholyte production from MFCs using urine as a feedstock. Cylindrical MFCs were assembled with fine fire clay of different thicknesses (2.5, 5 and 10 mm) as structural and membrane materials. The power generated increased when the membrane thickness decreased, reaching 2.1 ± 0.19 mW per single MFC (2.5 mm), which was 50% higher than that from the MFCs with the thickest membrane (10 mm). The amount of catholyte collected also decreased with the wall thickness, whereas the pH increased. Evidence shows that the catholyte composition varies with the wall thickness of the ceramic membrane. The possibility of producing different quality of catholyte from urine opens a new field of study in water reuse and resource recovery for practical implementation.

  6. [DEFINITION OF INTERRELATION BETWEEN AMINOACID COMPOSITION OF URINE AND BONE TISSUE DENSITY AT CHILDREN WITH ACUTE LEUKAEMIA FOR ONCOHEMATOLOGICAL PATHOLOGY RISK GROUP FORMATION].

    PubMed

    Bebeshko, V G; Bruslova, E M; Volodina, T T; Tsvietkova, N M; Lyashenko, L A; Pushkareva, T I; Voloshko, V I; Veselskaya, L P; Chernysh, T A; Trikhleb, I V

    2014-12-01

    Age and sexual indexies of densitometry at patients with acute leukemia (AL) and healthy children are presented. 31% of children with AL during the initial period of disease had manifestations of the osteopenic syndrome. At patients with AL more often than at healthy children anomalies of development of front part of skull are defined. The partial contribution of free and peptides-connencted oxyproline in urine at AL patients differs in comparison with control group that is caused by modification or deficiency of the corresponding enzymes. 30% of patients with AL had raised concentration of free oxyproline in urine, and lowered glycine concentration that testifies to the increased disintegration of collagen and deficiency of tile plastic material necessary for collagene-forming processes. The obtained data should be considered for forming of risk group on oncohematological pathology at children.

  7. Fluid consumption, total water intake and first morning urine osmolality in Spanish adolescents from Zaragoza: data from the HELENA study.

    PubMed

    Iglesia, I; Santaliestra-Pasías, A M; Bel-Serrat, S; Sadalla-Collese, T; Miguel-Berges, M L; Moreno, L A

    2016-05-01

    The objective of the study is to describe the hydration status and to assess the main food- and/or fluid intake-associated factors in healthy adolescents. A total of 194 adolescents from the city of Zaragoza aged 12.5-17.5 years (99 males) participating in the 'Healthy Lifestyle in Europe by Nutrition in Adolescence' (HELENA) cross-sectional study were included. First morning urine was collected, and osmolality was determined by freezing point depression osmometer. A self-reported computer-based 24-h dietary recall was applied the same day of the urine collection. Analysis of variance, Kruskal-Wallis procedure or Pearson's χ(2) analyses was used to examine the group associations. Seventy-one percent of adolescents did not meet the European Food Safety Agency (EFSA) recommendations for average total water intake (TWI), and 68% had high first morning urine osmolality values. TWI and the proportion of those meeting EFSA reference values significantly (P<0.05) decreased with increased osmolality. Males who met the EFSA recommendations consumed significantly (P<0.05) more plain water (1035.13 vs 582.68 ml) and dairy drinks (368.13 vs 226.68 ml) than those who did not. In females, the consumption of water (1359.41 vs 620.44 ml) and sugar-sweetened beverages (214.61 vs 127.42 ml) was significantly higher in those meeting the EFSA recommendations than in those who did not. First morning urine osmolality was associated with vegetables (unstandardized β: -0.6; 95% confidence interval (CI): -1.02 and -0.18) and fruits intake (β: -0.41; 95% CI: -0.63 and -0.19) in males and with dairy drinks (β: -0.39; 95% CI: -0.76 and -0.02) and fruits (β: -0.41; 95% CI: -0.73 and -0.10) in females. There was a high prevalence of inadequate TWI and high urine osmolality among these Spanish adolescents. Lower urine osmolality was associated with higher consumption of vegetables in males, dairy drinks in females and fruits in both males and females.

  8. Proposal for single and mixture biological exposure limits for sevoflurane and nitrous oxide at low occupational exposure levels.

    PubMed

    Accorsi, Antonio; Valenti, Simona; Barbieri, Anna; Raffi, Giovanni Battista; Violante, Francesco Saverio

    2003-03-01

    Assessment of individual exposures to sevoflurane plus nitrous oxide (N(2)O) by biological monitoring of unmodified analytes in post-shift urine of exposed personnel. Anaesthetics in urine and breathing area were monitored in 124 subjects in 11 operating theatres. Passive samplers were collected after 2.5-7 h of exposure, at the same time as post-shift urinary samples, to evaluate the individual time-weighted average (TWA) exposures to sevoflurane and N(2)O. A static headspace sampler coupled with a gas chromatograph mass spectrometer was used for analytical determinations (sensitivity sufficient to reveal biological/environmental exposures of 0.1 microg/l(urine) and 50 ppb for sevoflurane, and 1 microg/l(urine) and 80 ppb for N(2)O). Median (range) post-shift urinary and environmental values were 1.2 microg/l(urine) (0.1-5.0) and 0.4 ppm (0.05-3.0) for sevoflurane ( n=107) and 10.9 microg/l(urine) (0.5-74.9) and 8.6 ppm (0.2-123.4) for N(2)O ( n=121) (all low-exposure range). At log-log regression, urinary levels closely correlated with environmental data (sevoflurane, r(2)=0.7538; N(2)O, r(2)=0.8749). Biological equivalent limits (BELs) based on National Institute for Occupational Safety and Health (NIOSH) TWA exposure limits, calculated as means of regression slope and y-intercept, were 3.6 microg/l(urine) for sevoflurane (corresponding to 2 ppm) and 22.3 microg/l(urine) for N(2)O (corresponding to 25 ppm). Individual "mixture BELs", which we calculated by applying the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) mix formula to biomarker values and using the obtained NIOSH-based BELs as a reference, closely correlated with mixture TLVs (rho=0.816, Lin's concordance test). CONCLUSIONS. We propose urinary sevoflurane as a new, specific, internal dose biomarker for routine biological monitoring of personal exposures among operating-theatre personnel, and use of reliable "mixture BELs" to provide safer levels of internal exposure for workers exposed to mixtures of sevoflurane and N(2)O, and conceivably also to other mixtures of toxicants with possible additive effects.

  9. Stainless steel welding and semen quality.

    PubMed

    Jelnes, J E; Knudsen, L E

    1988-01-01

    Questionnaire studies of patients from fertility clinics suggest that welders may have an increased risk of reduced semen quality. In this study, welders and nonwelders from the same plants were asked to provide blood, urine, and semen samples. Urine was analyzed for chromium and nickel, and for mutagenic activity and metal concentration; blood for metal concentrations, immunoglobulin G, total protein, and measures of genotoxicity in lymphocytes; and semen was evaluated by standard semen analysis. Results of the semen evaluation, presented here, showed no difference in semen quality between welders and nonwelders. Because the metal dust exposure of nonwelders in the plant may be higher than that in the general population, welders were also compared to referents not working in the metal industry. Again, no decrease in semen quality associated with welding was demonstrated.

  10. Dual Fan Separator within the Universal Waste Management System

    NASA Technical Reports Server (NTRS)

    Stapleton, Tom; Converse, Dave; Broyan, James Lee, Jr.

    2014-01-01

    Since NASA's new spacecraft in development for both LEO and Deep Space capability have considerable crew volume reduction in comparison to the Space Shuttle, the need became apparent for a smaller commode. In response the Universal Waste Management System (UWMS) was designed, resulting in an 80% volume reduction from the last US commode, while enhancing performance. The ISS WMS and previous shuttle commodes have a fan supplying air flow to capture feces and a separator to capture urine and separate air from the captured air/urine mixture. The UWMS combined both rotating equipment components into a single unit, referred to at the Dual Fan Separator (DFS). The combination of these components resulted in considerable packaging efficiency and weight reduction, removing inter-component plumbing, individual mounting configurations and required only a single motor and motor controller, in some of the intended UWMS platform applications the urine is pumped to the ISS Urine Processor Assembly (UPA) system. It requires the DFS to include less than 2.00% air inclusion, by volume, in the delivered urine. The rotational speed needs to be kept as low as possible in centrifugal urine separators to reduce air inclusion in the pumped fluid, while fans depend on rotational speed to develop delivered head. To satisfy these conflicting requirements, a gear reducer was included, allowing the fans to rotate at a much higher speed than the separator. This paper outlines the studies and analysis performed to develop the DFS configuration. The studies included a configuration trade study, dynamic stability analysis of the rotating bodies and a performance analysis of included labyrinth seals. NASA is considering a program to fly the UWMS aboard the ISS as a flight experiment. The goal of this activity is to advance the Technical Readiness Level (TRL) of the DFS and determine if the concept is ready to be included as part of the flight experiment deliverable.

  11. Back to Basics: Is There a Good Reason to Not Systematically Measure Urine Creatinine in Acute Kidney Injury Monitoring?

    PubMed

    Maciel, Alexandre Toledo

    2016-01-01

    Regardless of the recent advancements in the understanding of the pathophysiology of acute kidney injury (AKI), its diagnosis remains fundamentally dependent on the serum creatinine (sCr) level and urine output (UO), both of which are considered late markers of AKI, offering only a vague idea of the actual creatinine clearance (CrCl). Although not ideal, CrCl is still the most common alternative of the glomerular filtration rate (GFR) in clinical practice. It is generally accepted that early diagnosis of AKI must reveal kidney impairment before sCr increases. Much effort has been made to find tubular and glomerular markers of injury which increase (in blood and/or in urine) before the 'official' diagnosis of AKI. Most of these markers are expensive and not widely available, especially in developing countries. Urine creatinine (CrU), the major link between sCr and UO, has been systematically ignored and clinicians are usually unaware of its value. The reasons for this are unclear, but it may be related to the lack of a reference range, dependence of its concentration value on the urine flow (which in turn is only adequately assessed with an indwelling urinary catheter) and the clinical unavailability of its counterbalance part - creatinine production. Changes in urine tend to precede changes in blood in the course of AKI development and recovery. Hence, it is important to bear in mind that changes in sCr signal renal dysfunction with a significant delay. The search for a more dynamic, 'real-time' but pragmatic assessment of renal function, especially in patients at risk of abrupt decrease in GFR is certainly one of the most relevant focus of research in the field of AKI monitoring. Systematic CrU assessment may be highly relevant in this case. © 2016 S. Karger AG, Basel.

  12. Anxiety-free Urinalysis.

    ERIC Educational Resources Information Center

    Schwartz, Marjorie F.

    1989-01-01

    Discusses simple analysis of urine in the classroom. Describes the materials and procedures for the analysis. Provides a laboratory report giving characteristics of: (1) odor, color, and clarity; (2) specific gravity; (3) sediment; (4) test strips; and (5) albumin and phosphates. (YP)

  13. Innovative and cost-effective management of large omphalocele.

    PubMed

    Gupta, Parthapratim

    2007-06-01

    The aim of this study was to develop a method of management of large omphalocele, with easily available inexpensive materials. The efficacy of using the plastic of urine collection bag and paper stapler, in creating the "silo" for the management of 3 newborns with such defects, were assessed. All operations were done within 36 hours of birth. A silo was created with the plastic of a sterile urine collection bag, which was stapled with a paper stapler at its free margin. The omphalocele was gradually reduced every 24 to 48 hours, using the stapler, until the contents were reduced, when the abdominal wall was repaired. The mean time taken to close the abdominal defect was 34 days. All patients could be breast-fed from 48 hours after the first stage is done. Rooming in was done by day 7. None of the babies required assisted ventilation. This method is simple and cost-effective, using minimally expensive, easily available materials.

  14. Comparison of population iodine estimates from 24-hour urine and timed-spot urine samples.

    PubMed

    Perrine, Cria G; Cogswell, Mary E; Swanson, Christine A; Sullivan, Kevin M; Chen, Te-Ching; Carriquiry, Alicia L; Dodd, Kevin W; Caldwell, Kathleen L; Wang, Chia-Yih

    2014-04-01

    Median urine iodine concentration (UIC; μg/L) in spot urine samples is recommended for monitoring population iodine status. Other common measures are iodine:creatinine ratio (I/Cr; μg/g) and estimated 24-hour urine iodine excretion (UIE; I/Cr × predicted 24-hour Cr; μg/day). Despite different units, these measures are often used interchangeably, and it is unclear how they compare with the reference standard 24-hour UIE. Volunteers aged 18-39 years collected all their urine samples for 24 hours (n=400). Voids from morning, afternoon, evening, overnight, and a composite 24-hour sample were analyzed for iodine. We calculated median observed 24-hour UIE and 24-hour UIC, and spot UIC, I/Cr, and two measures of estimated UIE calculated using predicted 24-hour Cr from published estimates by Kesteloot and Joosens (varies by age and sex) and published equations by Mage et al. (varies by age, sex, race, and anthropometric measures). We examined mean differences and relative difference across iodine excretion levels using Bland-Altman plots. Median 24-hour UIE was 173.6 μg/day and 24-hour UIC was 144.8 μg/L. From timed-spot urine samples, estimates were: UIC 147.3-156.2 μg/L; I/Cr 103.6-114.3 μg/g, estimated 24-hour UIE (Kesteloot and Joosens) 145.7-163.3 μg/day; and estimated 24-hour UIE (Mage) 176.5-187.7 μg/day. Iodine measures did not vary consistently by timing of spot urine collection. Compared with observed 24-hour UIE, on average, estimated (Mage) 24-hour UIE was not significantly different, while estimated 24-hour UIE (Kesteloot and Joosens) was significantly different for some ethnicity/sex groups. Compared with 24-hour UIC, on average, spot UIC did not differ. Estimates of UIC, I/Cr, and estimated 24-hour UIE (I/Cr × predicted 24-hour Cr) from spot urine samples should not be used interchangeably. Estimated 24-hour UIE, where predicted 24-hour Cr varies by age, sex, ethnicity, and anthropometric measures and was calculated with prediction equations using data from the sample, was more comparable to observed 24-hour UIE than when predicted 24-hour Cr was from published estimates from a different population. However, currently no cutoffs exist to interpret population estimated 24-hour UIE values.

  15. Isolation and Molecular Detection of Gram Negative Bacteria Causing Urinary Tract Infection in Patients Referred to Shahrekord Hospitals, Iran.

    PubMed

    Tajbakhsh, Elahe; Tajbakhsh, Sara; Khamesipour, Faham

    2015-05-01

    Urinary Tract Infections (UTI), and their complications, cause serious health problems, which affect millions of people every year. Infections of the urinary tract are the second most common type of infection in the body and approximately 20% of women are especially prone to UTIs for reasons not yet well understood. Urinary Tract Infections in men are not as common as in women yet can be very serious when they do occur. Accurate identification of bacterial isolates is an essential task of the clinical microbiology laboratory. The purpose of this study was to determine the incidence and variety of the causative microbial agents of UTIs in patients who had referred to a medical laboratory of Kashani and Hajar hospital in Shahrekord, Iran. In this cross-sectional study 147 urine samples of patients (urine test results were positive for UTIs) were examined during April to September 2013. A total of 147 urine samples of patients with clinical symptoms of UTI who had been referred to a medical laboratory of Kashani and Hajar hospital in Shahrekord (Iran), were collected and processed immediately for laboratory analysis. Escherichia coli was identified as the most common causative agent of UTIs (51.70% of total isolates in both sexes), followed by Klebsiella pneumoniae (K. Pneumoniae) (16.32%). Frequency of Proteus spp., Acinetobacter spp., Entrobacter spp., Citrobacter spp., Pseudomonas aeruginosa (P. aeruginosa) and Providencia spp. was 10.88%, 6.12%, 5.44%, 4.08%, 3.40% and 2.04%, respectively. Statistical analysis by Fisher exact test showed that there was no significant relationship between the type of bacteria and gender (P > 0.05). Chi square test showed that there was no significant relationship between the type of bacteria and the use of catheter and age group (P > 0.05). However, there was a significant relationship between the type of bacteria and the history of hospitalization (P > 0.05). Our findings implied that a wide range of bacteria could be involved in creating urinary tract infection in patients referred to a medical laboratory of Kashani and Hajar hospital in Shahrekord, Iran. Regardless of age, sex and the use of catheter, a wide range of bacteria could be involved in urinary tract infections.

  16. Validating urinary measurement of beta-2-microglobulin with a Roche reagent kit designed for serum measurements.

    PubMed

    Chan, Pak Cheung R; Kulasingam, Vathany; Lem-Ragosnig, Bonny

    2012-11-01

    To validate the use of a Roche serum beta-2-microglobulin (B2MG) kit for urinary B2MG measurements, and to establish reference limits for urinary B2MG/creatinine ratio from healthy individuals. The Roche B2MG Tina-Quant serum kit was used to measure urinary B2MG immunoturbidimetrically. Using human urine as a diluent, the B2MG method was linear from 73-2156 μg/L. The imprecision on a commercially available urine QC was 4.4% at a concentration of 380 μg/L. Limit of quantification at <20% CV was 40 μg/L. Method comparison with Immulite 2000 (Siemens) yielded slope=1.180 (95% CI 1.14-1.22), intercept=11.5 (95% CI -3.6-26.6), SEE=27.6 and r=0.99 (n=26) by the Deming regression analysis. The upper reference limit of B2MG/creatinine ratio determined from 195 healthy adults was 29 μg/mmol (97.5th centile). The serum B2MG Tina Quant reagent kit is acceptable to measure urinary B2MG. Copyright © 2012. Published by Elsevier Inc.

  17. Candida tropicalis biofilms: artificial urine, urinary catheters and flow model.

    PubMed

    Negri, Melyssa; Silva, Sónia; Henriques, Mariana; Azeredo, Joana; Svidzinski, Terezinha; Oliveira, Rosário

    2011-10-01

    Adhesion to medical devices and biofilm formation are considered important virulence factors of Candida tropicalis. This work aimed to use artificial urine (AU) and urinary catheters, under flow conditions, for studying C. tropicalis biofilms. Adhesion and biofilm formation on silicone and latex urinary catheters were quantified by crystal violet staining and determination of colony forming units. Candida surface hydrophobicity was also evaluated, as well as the biofilms' matrix content in terms of proteins and carbohydrates. Candida tropicalis was able to adhere and to form biofilms along the entire length of the catheters under flow conditions. It was found that the isolate U69 adhered significantly more to both types of catheters than did the reference strain. However, U69 biofilms contained significantly less cultivable cells and higher biofilm biomass than those of the reference strain. Detachment of cells from biofilms on latex catheter was lower compared to silicone catheter. This model using AU appeared to be suitable for studies mimicking the real body conditions. Additionally, C. tropicalis was in fact able to colonize urinary catheters in the presence of AU and to detach from these catheters, demonstrating their capacity to colonize distal sites.

  18. Detection and identification of drugs and toxicants in human body fluids by liquid chromatography-tandem mass spectrometry under data-dependent acquisition control and automated database search.

    PubMed

    Oberacher, Herbert; Schubert, Birthe; Libiseller, Kathrin; Schweissgut, Anna

    2013-04-03

    Systematic toxicological analysis (STA) is aimed at detecting and identifying all substances of toxicological relevance (i.e. drugs, drugs of abuse, poisons and/or their metabolites) in biological material. Particularly, gas chromatography-mass spectrometry (GC/MS) represents a competent and commonly applied screening and confirmation tool. Herein, we present an untargeted liquid chromatography-tandem mass spectrometry (LC/MS/MS) assay aimed to complement existing GC/MS screening for the detection and identification of drugs in blood, plasma and urine samples. Solid-phase extraction was accomplished on mixed-mode cartridges. LC was based on gradient elution in a miniaturized C18 column. High resolution electrospray ionization-MS/MS in positive ion mode with data-dependent acquisition control was used to generate tandem mass spectral information that enabled compound identification via automated library search in the "Wiley Registry of Tandem Mass Spectral Data, MSforID". Fitness of the developed LC/MS/MS method for application in STA in terms of selectivity, detection capability and reliability of identification (sensitivity/specificity) was demonstrated with blank samples, certified reference materials, proficiency test samples, and authentic casework samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Diuretic Activity of Ethanolic Root Extract of Mimosa Pudica in Albino Rats

    PubMed Central

    SL, Shruthi; PS, Vaibhavi; VH, Pushpa; AM, Satish; Sibgatullah, Mohammad

    2015-01-01

    Introducation Diuretics are the drugs which increase the urine output. This property is useful in various pathological conditions of fluid overload. The presently available diuretics have lot of adverse effects. Our study has evaluated the diuretic activity of ethanolic root extract of Mimosa pudica as an alternative/new drug which may induce diuresis. Aim To evaluate the diuretic activity of ethanolic root extract of Mimosa pudicaa in albino rats. Materials and Methods Ethanolic root extract of Mimosa pudica (EEMP) was prepared using soxhlet’s apparatus. Albino rats were divided into 5 groups of 6 rats each. Group-I (Control) received distilled water 25ml/kg orally. Group-II (Standard) received Furosemide 20mg/kg orally. Group-III received EEMP 100 mg/kg, Group-IV received EEMP 200 mg/kg and Group-V received EEMP 400 mg/kg. The urine samples were collected for all the groups upto 5 hours after dosing and urine volume was measured. Urine was analysed for electrolytes (Na+, K+ and Cl-). ANOVA, Dunnet’s test and p-values were measured and data was analysed. Results EEMP exhibited significant diuretic activity by increasing urine volume and also by enhancing elimination of Sodium (Na+), Potassium (K+) and Chloride (Cl-) at doses of 100 and 200mg/kg. Conclusion EEMP possesses significant diuretic activity and has a beneficial role in volume overload conditions. PMID:26870704

  20. The determination of polycyclic aromatic hydrocarbons in human urine by high-resolution gas chromatography-mass spectrometry.

    PubMed

    Cho, Sung-Hee; Lee, Sun-Kyung; Kim, Chong Hyeak

    2018-05-01

    Polycyclic aromatic hydrocarbons (PAHs), organic compounds formed by at least two condensed aromatic rings, are ubiquitous environmental pollutants that are produced by incomplete combustion of organic materials. PAHs have been classified as carcinogenIC to humans by the International Agency for Research on Cancer, because they can bind to DNA, causing mutations. Therefore, the levels of PAHs in human urine can be used as an indicator for potential carcinogenesis and cell mutation. An analytical method was developed for the accurate measurement of PAHs in urine using high-resolution gas chromatography-mass spectrometry. Urine samples were extracted by an Oasis HLB extraction cartridge after enzymatic hydrolysis with a β-glucuronidase/arylsulfatase cocktail. The 18 PAHs were separated using an Agilent DB-5 MS capillary column (30 m × 0.25 mm, 0.25 μm) and monitored by time-of-flight mass spectrometry. Under the optimized method, the linearity of calibration curves was >0.994. The limits of detection at a signal-to-noise ratio of 3 were 10-100 ng/L. The coefficients of variation were in the range of 0.4-9.0%. The present method was highly accurate for simultaneous determination of 18 PAHs in human urine and could be applied to monitoring and biomedical investigations to check exposure of PAHs. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Steroid isotopic standards for gas chromatography-combustion isotope ratio mass spectrometry (GCC-IRMS).

    PubMed

    Zhang, Ying; Tobias, Herbert J; Brenna, J Thomas

    2009-03-01

    Carbon isotope ratio (CIR) analysis of urinary steroids using gas chromatography-combustion isotope ratio mass spectrometry (GCC-IRMS) is a recognized test to detect illicit doping with synthetic testosterone. There are currently no universally used steroid isotopic standards (SIS). We adapted a protocol to prepare isotopically uniform steroids for use as a calibrant in GCC-IRMS that can be analyzed under the same conditions as used for steroids extracted from urine. Two separate SIS containing a mixture of steroids were created and coded CU/USADA 33-1 and CU/USADA 34-1, containing acetates and native steroids, respectively. CU/USADA 33-1 contains 5alpha-androstan-3beta-ol acetate (5alpha-A-AC), 5alpha-androstan-3alpha-ol-17-one acetate (androsterone acetate, A-AC), 5beta-androstan-3alpha-ol-11, 17-dione acetate (11-ketoetiocholanolone acetate, 11k-AC) and 5alpha-cholestane (Cne). CU/USADA 34-1 contains 5beta-androstan-3alpha-ol-17-one (etiocholanolone, E), 5alpha-androstan-3alpha-ol-17-one (androsterone, A), and 5beta-pregnane-3alpha, 20alpha-diol (5betaP). Each mixture was prepared and dispensed into a set of about 100 ampoules using a protocol carefully designed to minimize isotopic fractionation and contamination. A natural gas reference material, NIST RM 8559, traceable to the international standard Vienna PeeDee Belemnite (VPDB) was used to calibrate the SIS. Absolute delta(13)C(VPDB) and Deltadelta(13)C(VPDB) values from randomly selected ampoules from both SIS indicate uniformity of steroid isotopic composition within measurement reproducibility, SD(delta(13)C)<0.2 per thousand. This procedure for creation of isotopic steroid mixtures results in consistent standards with isotope ratios traceable to the relevant international reference material.

  2. Development of biomonitoring equivalents for barium in urine and plasma for interpreting human biomonitoring data.

    PubMed

    Poddalgoda, Devika; Macey, Kristin; Assad, Henry; Krishnan, Kannan

    2017-06-01

    The objectives of the present work were: (1) to assemble population-level biomonitoring data to identify the concentrations of urinary and plasma barium across the general population; and (2) to derive biomonitoring equivalents (BEs) for barium in urine and plasma in order to facilitate the interpretation of barium concentrations in the biological matrices. In population level biomonitoring studies, barium has been measured in urine in the U.S. (NHANES study), but no such data on plasma barium levels were identified. The BE values for plasma and urine were derived from U.S. EPA's reference dose (RfD) of 0.2 mg/kg bw/d, based on a lower confidence limit on the benchmark dose (BMDL 05 ) of 63 mg/kg bw/d. The plasma BE (9 μg Ba/L) was derived by regression analysis of the near-steady-state plasma concentrations associated with the administered doses in animals exposed to barium chloride dihydrate in drinking water for 2-years in a NTP study. Using a human urinary excretion fraction of 0.023, a BE for urinary barium (0.19 mg/L or 0.25 mg/g creatinine) was derived for US EPA's RfD. The median and the 95 th percentile barium urine concentrations of the general population in U.S. are below the BE determined in this study, indicating that the population exposure to inorganic barium is expected to be below the exposure guidance value of 0.2 mg/kg bw/d. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  3. Screening for the synthetic cannabinoid JWH-018 and its major metabolites in human doping controls.

    PubMed

    Möller, Ines; Wintermeyer, Annette; Bender, Katja; Jübner, Martin; Thomas, Andreas; Krug, Oliver; Schänzer, Wilhelm; Thevis, Mario

    2011-09-01

    Referred to as 'spice', several new drugs, advertised as herbal blends, have appeared on the market in the last few years, in which the synthetic cannabinoids JWH-018 and a C(8) homologue of CP 47,497 were identified as major active ingredients. Due to their reported cannabis-like effects, many European countries have banned these substances. The World Anti-Doping Agency has also explicitly prohibited synthetic cannabinoids in elite sport in-competition. Since urine specimens have been the preferred doping control samples, the elucidation of the metabolic pathways of these substances is of particular importance to implement them in sports drug testing programmes. In a recent report, an in vitro phase-I metabolism study of JWH-018 was presented yielding mainly hydroxylated and N-dealkylated metabolites. Due to these findings, a urine sample of a healthy man declaring to have smoked a 'spice' product was screened for potential phase-I and -II metabolites by high-resolution/high-accuracy mass spectrometry in the present report. The majority of the phase-I metabolites observed in earlier in vitro studies of JWH-018 were detected in this urine specimen and furthermore most of their respective monoglucuronides. As no intact JWH-018 was detectable, the monohydroxylated metabolite being the most abundant one was chosen as a target analyte for sports drug testing purposes; a detection method was subsequently developed and validated in accordance to conventional screening protocols based on enzymatic hydrolysis, liquid-liquid extraction, and liquid chromatography/electrospray tandem mass spectrometry analysis. The method was applied to approximately 7500 urine doping control samples yielding two JWH-018 findings and demonstrated its capability for a sensitive and selective identification of JWH-018 and its metabolites in human urine. Copyright © 2010 John Wiley & Sons, Ltd.

  4. Uric acid, an important screening tool to detect inborn errors of metabolism: a case series.

    PubMed

    Jasinge, Eresha; Kularatnam, Grace Angeline Malarnangai; Dilanthi, Hewa Warawitage; Vidanapathirana, Dinesha Maduri; Jayasena, Kandana Liyanage Subhashinie Priyadarshika Kapilani Menike; Chandrasiri, Nambage Dona Priyani Dhammika; Indika, Neluwa Liyanage Ruwan; Ratnayake, Pyara Dilani; Gunasekara, Vindya Nandani; Fairbanks, Lynette Dianne; Stiburkova, Blanka

    2017-09-06

    Uric acid is the metabolic end product of purine metabolism in humans. Altered serum and urine uric acid level (both above and below the reference ranges) is an indispensable marker in detecting rare inborn errors of metabolism. We describe different case scenarios of 4 Sri Lankan patients related to abnormal uric acid levels in blood and urine. CASE 1: A one-and-half-year-old boy was investigated for haematuria and a calculus in the bladder. Xanthine crystals were seen in microscopic examination of urine sediment. Low uric acid concentrations in serum and low urinary fractional excretion of uric acid associated with high urinary excretion of xanthine and hypoxanthine were compatible with xanthine oxidase deficiency. CASE 2: An 8-month-old boy presented with intractable seizures, feeding difficulties, screaming episodes, microcephaly, facial dysmorphism and severe neuro developmental delay. Low uric acid level in serum, low fractional excretion of uric acid and radiological findings were consistent with possible molybdenum cofactor deficiency. Diagnosis was confirmed by elevated levels of xanthine, hypoxanthine and sulfocysteine levels in urine. CASE 3: A 3-year-10-month-old boy presented with global developmental delay, failure to thrive, dystonia and self-destructive behaviour. High uric acid levels in serum, increased fractional excretion of uric acid and absent hypoxanthine-guanine phosphoribosyltransferase enzyme level confirmed the diagnosis of Lesch-Nyhan syndrome. CASE 4: A 9-year-old boy was investigated for lower abdominal pain, gross haematuria and right renal calculus. Low uric acid level in serum and increased fractional excretion of uric acid pointed towards hereditary renal hypouricaemia which was confirmed by genetic studies. Abnormal uric acid level in blood and urine is a valuable tool in screening for clinical conditions related to derangement of the nucleic acid metabolic pathway.

  5. Modelling the acid/base 1H NMR chemical shift limits of metabolites in human urine.

    PubMed

    Tredwell, Gregory D; Bundy, Jacob G; De Iorio, Maria; Ebbels, Timothy M D

    2016-01-01

    Despite the use of buffering agents the 1 H NMR spectra of biofluid samples in metabolic profiling investigations typically suffer from extensive peak frequency shifting between spectra. These chemical shift changes are mainly due to differences in pH and divalent metal ion concentrations between the samples. This frequency shifting results in a correspondence problem: it can be hard to register the same peak as belonging to the same molecule across multiple samples. The problem is especially acute for urine, which can have a wide range of ionic concentrations between different samples. To investigate the acid, base and metal ion dependent 1 H NMR chemical shift variations and limits of the main metabolites in a complex biological mixture. Urine samples from five different individuals were collected and pooled, and pre-treated with Chelex-100 ion exchange resin. Urine samples were either treated with either HCl or NaOH, or were supplemented with various concentrations of CaCl 2 , MgCl 2 , NaCl or KCl, and their 1 H NMR spectra were acquired. Nonlinear fitting was used to derive acid dissociation constants and acid and base chemical shift limits for peaks from 33 identified metabolites. Peak pH titration curves for a further 65 unidentified peaks were also obtained for future reference. Furthermore, the peak variations induced by the main metal ions present in urine, Na + , K + , Ca 2+ and Mg 2+ , were also measured. These data will be a valuable resource for 1 H NMR metabolite profiling experiments and for the development of automated metabolite alignment and identification algorithms for 1 H NMR spectra.

  6. Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.

    PubMed

    Doyle, Kelly; Strathmann, Frederick G

    2017-02-01

    This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.

  7. Simultaneous LC-MS/MS determination of JWH-210, RCS-4, ∆(9)-tetrahydrocannabinol, and their main metabolites in pig and human serum, whole blood, and urine for comparing pharmacokinetic data.

    PubMed

    Schaefer, Nadine; Kettner, Mattias; Laschke, Matthias W; Schlote, Julia; Peters, Benjamin; Bregel, Dietmar; Menger, Michael D; Maurer, Hans H; Ewald, Andreas H; Schmidt, Peter H

    2015-05-01

    A series of new synthetic cannabinoids (SC) has been consumed without any toxicological testing. For example, pharmacokinetic data have to be collected from forensic toxicological case work and/or animal studies. To develop a corresponding model for assessing such data, samples of controlled pig studies with two selected SC (JWH-210, RCS-4) and, as reference, ∆(9)-tetrahydrocannabinol (THC) should be analyzed as well as those of human cases. Therefore, a method for determination of JWH-210, RCS-4, THC, and their main metabolites in pig and human serum, whole blood, and urine samples is presented. Specimens were analyzed by liquid-chromatography tandem mass spectrometry and multiple-reaction monitoring with three transitions per compound. Full validation was carried out for the pig specimens and cross-validation for the human specimens concerning precision and bias. For the pig studies, the limits of detection were between 0.05 and 0.50 ng/mL in serum and whole blood and between 0.05 and 1.0 ng/mL in urine, the lower limits of quantification between 0.25 and 1.0 ng/mL in serum and 0.50 and 2.0 ng/mL in whole blood and urine, and the intra- and interday precision values lower than 15% and bias values within ±15%. The applicability was tested with samples taken from a pharmacokinetic pilot study with pigs following intravenous administration of a mixture of 200 μg/kg body mass dose each of JWH-210, RCS-4, and THC. The cross-validation data for human serum, whole blood, and urine showed that this approach should also be suitable for human specimens, e.g., of clinical or forensic cases.

  8. The Diagnostic Value of Urine Lipoarabinomannan (LAM) Antigen in Childhood Tuberculosis

    PubMed Central

    Nursiloningrum, Erlin; Arthamin, Maimun Zulhaidah; Olivianto, Ery; Chandrakusuma, Mas Slamet

    2017-01-01

    Introduction Diagnosis of Tuberculosis (TB) in children is difficult because the clinical presentation is not specific, the chest X-ray interpretation has low accuracy and sputum sample is difficult to obtain. Antigen detection test such as rapid urine LAM is a non-invasive alternative for diagnosing TB . Lipoarabinomannan (LAM) is the main component of M.tuberculosis cell wall. Aim To determine the diagnostic value of urinary LAM antigen for diagnosis of childhood TB. Materials and Methods In the present cross-sectional study, subjects were included using consecutive sampling method. All the children aged 0-14 years Suspected of pulmonary or extra pulmonary TB suffering from cough more than two weeks, fever without clear aetiology, loss of body weight or poor weight gain, fatigue, malaise, chronic lymph node enlargement, spine angulation, joint swelling and had history of contact with positive sputum smear adult TB patient were enrolled in the study. Pulmonary and extra pulmonary diagnosis was based on clinical presentation, Tuberculin Skin Test (TST), chest X-ray, Acid Fast Bacillus (AFB) staining and or sputum culture. Urinary LAM level was measured by using Enzyme-Linked Immunosorbent Assay (ELISA). Cut off value and Area Under the Curve (AUC) were determined using ROC statistical analysis (SPSS 21.0). Sensitivity and specificity was measured from 2x2 cross table. Results Out of 61 subjects suspected as TB, 49 (80.3%) were eventually diagnosed with TB. Of those diagnosed with TB, 21 (42.9%) were microbiologically confirmed cases either by sputum microscopy (34.7%) or culture (8.2%), whereas 28 subjects were unconfirmed cases (57.1%). The urinary LAM level was higher in subjects with TB (1.80+1.02) mg/l compared to non-TB group (0.46+0.3) mg/l; p<0.001(independent t-test). Urine LAM had 83% sensitivity and 85% specificity with cut off value 0.98 mg/l using microbiological and clinical confirmation as standard reference and 33% sensitivity and 60% specificity with cut off value 1.69 mg/l using microbiological confirmation only. Conclusion Urinary LAM has good diagnostic value for childhood TB diagnosis. PMID:28511392

  9. Occupational exposure to airborne mercury during gold mining operations near El Callao, Venezuela.

    PubMed

    Drake, P L; Rojas, M; Reh, C M; Mueller, C A; Jenkins, F M

    2001-04-01

    The National Institute for Occupational Safety and Health (NIOSH) recently conducted a cross-sectional study during gold mining operations near El Callao, Venezuela. The purpose of the study was to assess mercury exposures and mercury-related microdamage to the kidneys. The study consisted of concurrent occupational hygiene and biological monitoring, and an examination of the processing techniques employed at the different mining facilities. Mercury was used in these facilities to remove gold by forming a mercury-gold amalgam. The gold was purified either by heating the amalgam in the open with a propane torch or by using a small retort. Thirty-eight workers participated in this study. Some participants were employed by a large mining company, while others were considered "informal miners" (self-employed). Mercury exposure was monitored by sampling air from the workers' breathing zones. These full-shift air samples were used to calculate time-weighted average (TWA) mercury exposure concentrations. A questionnaire was administered and a spot urine sample was collected. Each urine sample was analyzed for mercury, creatinine, and N-acetyl-beta-D-glucosaminidase (NAG). The range for the 8-h TWA airborne mercury exposure concentrations was 0.1 to 6,315 micrograms/m3, with a mean of 183 micrograms/m3. Twenty percent of the TWA airborne mercury exposure measurements were above the NIOSH recommended exposure limit (REL) of 50 micrograms/m3, and 26% exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) of 25 micrograms/m3. The mean urine mercury concentration was 101 micrograms/g creatinine (microgram/g-Cr), and the data ranged from 2.5 to 912 micrograms/g-Cr. Forty-two percent of the study participants had urine mercury concentrations that exceeded the ACGIH biological exposure index (BEI) of 35 micrograms/g-Cr. Urinary NAG excretion is considered a biological marker of preclinical, nonspecific microdamage to the kidney's proximal tubule cells. The mean urine NAG concentration was 3.6 International Units/g-Cr (IU/g-Cr) with a range of 0.5 to 11.5 IU/g-Cr. Three workers had urine NAG levels in excess of the reference values. Correlation analyses found statistically significant correlations between airborne mercury exposure and urine mercury level (P = 0.01), and between urine mercury level and urine NAG excretion (P = 0.01). In addition, the airborne mercury exposure data and urine mercury data were segregated by job tasks. A Wilcoxon rank sum test revealed significant correlations between tasks and mercury exposure (P = 0.03), and between tasks and urine mercury level (P = 0.02). The tasks with the highest mean airborne mercury exposures were "burning the mercury-gold amalgam" and "gold refining/smelting". Recommendations were provided for improving the retort design to better contain mercury, for ventilation in the gold shops, and for medical surveillance and educational programs.

  10. Impaired Urine Dilution Capability in HIV Stable Patients

    PubMed Central

    Belloso, Waldo H.; de Paz Sierra, Mariana; Navarro, Matilde; Sanchez, Marisa L.; Perelsztein, Ariel G.; Musso, Carlos G.

    2014-01-01

    Renal disease is a well-recognized complication among patients with HIV infection. Viral infection itself and the use of some antiretroviral drugs contribute to this condition. The thick ascending limb of Henle's loop (TALH) is the tubule segment where free water clearance is generated, determining along with glomerular filtration rate the kidney's ability to dilute urine. Objective. We analyzed the function of the proximal tubule and TALH in patients with HIV infection receiving or not tenofovir-containing antiretroviral treatment in comparison with healthy seronegative controls, by applying a tubular physiological test, hyposaline infusion test (Chaimowitz' test). Material & Methods. Chaimowitz' test was performed on 20 HIV positive volunteers who had normal renal functional parameters. The control group included 10 healthy volunteers. Results. After the test, both HIV groups had a significant reduction of serum sodium and osmolarity compared with the control group. Free water clearance was lower and urine osmolarity was higher in both HIV+ groups. Proximal tubular function was normal in both studied groups. Conclusion. The present study documented that proximal tubule sodium reabsorption was preserved while free water clearance and maximal urine dilution capability were reduced in stable HIV patients treated or not with tenofovir. PMID:24800076

  11. Gender's equality in evaluation of urine particles: Results of a multicenter study of the Italian Urinalysis Group.

    PubMed

    Manoni, Fabio; Gessoni, Gianluca; Alessio, Maria Grazia; Caleffi, Alberta; Saccani, Graziella; Epifani, Maria Grazia; Tinello, Agostino; Zorzan, Tatiana; Valverde, Sara; Caputo, Marco; Lippi, Giuseppe

    2014-01-01

    We performed a multicenter study to calculate the upper reference limits (URL) for urine particle quantification in mid-stream samples by using automated urine analyzers. Two laboratories tested 283 subjects using a Sysmex UF-100, two other laboratories tested 313 subjects using Sysmex UF-1000i, whereas two other laboratories tested 267 subjects using Iris IQ®200. The URLs of UF-100 in females and males were 7.8/μL and 6.7/μL for epithelial cells (EC), 11.1/μL and 9.9/μL for red blood cells (RBC), 10.2/μL and 9.7/μL for white blood cells (WBC), and 0.85/μL and 0.87/μL for cylinders (CAST). The URLs of UF-1000i in females and males were 7.6/μL and 7.1/μL for EC, 12.2/μL and 11.1/μL for RBC, 11.9/μL and 11.7/μL for WBC, and 0.88/μL and 0.86/μL for CAST. The URLs of Iris IQ®200 in females and males were 7.8/μL and 6.6/μL for EC, 12.4/μL and 10.1/μL for RBC, 10.9/μL and 9.9/μL for WBC, and 1.1/μL and 1.0/μL for CAST. The URLs obtained in this study were comparable to the lowest values previously reported in the literature. Moreover, no gender-related difference was observed, and analyzer-specific upper reference limits were very similar. © 2013.

  12. The risk of arsenic induced skin lesions in Bangladeshi men and women is affected by arsenic metabolism and the age at first exposure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindberg, Anna-Lena; Rahman, Mahfuzar; Persson, Lars-Ake

    2008-07-01

    It is known that a high fraction of methylarsonate (MA) in urine is a risk modifying factor for several arsenic induced health effects, including skin lesions, and that men are more susceptible for developing skin lesions than women. Thus, we aimed at elucidating the interaction between gender and arsenic metabolism for the risk of developing skin lesions. This study is part of a population-based case-referent study concerning the risk for skin lesions in relation to arsenic exposure via drinking water carried out in Matlab, a rural area 53km south-east of Dhaka, Bangladesh. We randomly selected 526 from 1579 referents andmore » all 504 cases for analysis of arsenic metabolites in urine using HPLC coupled to inductively coupled plasma mass spectrometry (HPLC-HG-ICPMS). The present study confirm previous studies, with the risk for skin lesions being almost three times higher in the highest tertile of %MA (adjusted OR 2.8, 95% CI: 1.9-4.2, p < 0.001) compared to the lowest tertile. The present study is the first to show that the well documented higher risk for men to develop arsenic-related skin lesions compared to women is mainly explained by the less efficient methylation of arsenic, as defined by a higher fraction of MA and lower fraction of DMA in the urine, among men. Our previously documented lower risk for skin lesions in individuals exposed since infancy, or before, was found to be independent of the observed arsenic methylation efficiency. Thus, it can be speculated that this is due to a programming effect of arsenic in utero.« less

  13. Headspace-programmed temperature vaporization-mass spectrometry for the rapid determination of possible volatile biomarkers of lung cancer in urine.

    PubMed

    Pérez Antón, Ana; Ramos, Álvaro García; Del Nogal Sánchez, Miguel; Pavón, José Luis Pérez; Cordero, Bernardo Moreno; Pozas, Ángel Pedro Crisolino

    2016-07-01

    We propose a new method for the rapid determination of five volatile compounds described in the literature as possible biomarkers of lung cancer in urine samples. The method is based on the coupling of a headspace sampler, a programmed temperature vaporizer in solvent-vent injection mode, and a mass spectrometer (HS-PTV-MS). This configuration is known as an electronic nose based on mass spectrometry. Once the method was developed, it was used for the analysis of urine samples from lung cancer patients and healthy individuals. Multivariate calibration models were employed to quantify the biomarker concentrations in the samples. The detection limits ranged between 0.16 and 21 μg/L. For the assignment of the samples to the patient group or the healthy individuals, the Wilcoxon signed-rank test was used, comparing the concentrations obtained with the median of a reference set of healthy individuals. To date, this is the first time that multivariate calibration and non-parametric methods have been combined to classify biological samples from profile signals obtained with an electronic nose. When significant differences in the concentration of one or more biomarkers were found with respect to the reference set, the sample is considered as a positive one and a new analysis was performed using a chromatographic method (HS-PTV-GC/MS) to confirm the result. The main advantage of the proposed HS-PTV-MS methodology is that no prior chromatographic separation and no sample manipulation are required, which allows an increase of the number of samples analyzed per hour and restricts the use of time-consuming techniques to only when necessary. Graphical abstract Schematic diagram of the developed methodology.

  14. Urinary excretion levels of water-soluble vitamins in pregnant and lactating women in Japan.

    PubMed

    Shibata, Katsumi; Fukuwatari, Tsutomu; Sasaki, Satoshi; Sano, Mitsue; Suzuki, Kahoru; Hiratsuka, Chiaki; Aoki, Asami; Nagai, Chiharu

    2013-01-01

    Recent studies have shown that the urinary excretion levels of water-soluble vitamins can be used as biomarkers for the nutritional status of these vitamins. To determine changes in the urinary excretion levels of water-soluble vitamins during pregnant and lactating stages, we surveyed and compared levels of nine water-soluble vitamins in control (non-pregnant and non-lactating women), pregnant and lactating women. Control women (n=37), women in the 2nd (16-27 wk, n=24) and 3rd trimester of pregnancy (over 28 wk, n=32), and early- (0-5 mo, n=54) and late-stage lactating (6-11 mo, n=49) women took part in the survey. The mean age of subjects was ~30 y, and mean height was ~160 cm. A single 24-h urine sample was collected 1 d after the completion of a validated, self-administered comprehensive diet history questionnaire to measure water-soluble vitamins or metabolites. The average intake of each water-soluble vitamin was ≍ the estimated average requirement value and adequate intake for the Japanese Dietary Reference Intakes in all life stages, except for vitamin B6 and folate intakes during pregnancy. No change was observed in the urinary excretion levels of vitamin B2, vitamin B6, vitamin B12, biotin or vitamin C among stages. Urine nicotinamide and folate levels were higher in pregnant women than in control women. Urine excretion level of vitamin B1 decreased during lactation and that of pantothenic acid decreased during pregnancy and lactation. These results provide valuable information for setting the Dietary Reference Intakes of water-soluble vitamins for pregnant and lactating women.

  15. Effect of Transitioning from Standard Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering

    DTIC Science & Technology

    2016-04-01

    Reference Material 2806b for Light Obscuration Particle Countering April 2016 UNCLASSIFIED UNCLASSIFIED Joel Schmitigal 27809 Standard Form 298 (Rev...Standard Reference Material 2806b for Light Obscuration Particle Countering 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering Joel Schmitigal Force Projection

  16. Crystallization processes derived from the interaction of urine and dolostone

    NASA Astrophysics Data System (ADS)

    Cámara, Beatriz; Alvarez de Buergo, Monica; Fort, Rafael

    2015-04-01

    The increase in the number of pets (mostly dogs), homeless people and the more recent open-air drinking sessions organized by young people in historical centers of European cities, derive on the augmentation of urinations on stone façades of the built cultural heritage. Up to now this process has been considered only under an undesirable aesthetical point of view and the insalubrious conditions it creates, together with the cleaning costs that the local governments have to assume. This study aims to confirm urine as a real source of soluble salts that can trigger the decay of building materials, especially of those of built cultural heritage of the historical centers of the cities, which are suffering the new social scenario described above. For this purpose, an experimental setup was designed and performed in the laboratory to simulate this process. 5 cm side cubic specimens of dolostone were subjected to 100 testing cycles of urine absorption by capillarity. The necessary amount of urine was collected by donors and stored following clinical protocol conditions. Each cycle consisted of imbibitions of the specimens in 3 mm high urine sheet for 3 hours, drying at 40°C in an oven for 20 hours and 1 hour cooling in a dessicator. At the end of the 100 cycles, small pieces of the specimens were cut, observed and analyzed with the aid of an environmental scanning electron microscope, which presents the advantage of no sample preparation. The sampled pieces were selected considering there were different sections in height in the specimens: a) a bottom section that corresponds to the section that has been immersed in the urine solution (3 mm); b) an interface section, immediately above the immersed area, which is the area most affected by the urine capillarity process, characterized by a strong yellowish color; c) the section that we have named as section of influence, which is subjected to the capillary absorption, although not so strongly than the interface section (these 3 sections, a) b) c) represent the first one centimeter of the specimen from the bottom); d) and the fourth and top section, which shows no influence by the effect of urine capillary absorption. The obtained results showed, from bottom to top, the following crystallized salts: a) abundant prismatic crystals enriched in P and Ca (calcium phosphate); b) amorphous round-shaped potassium sulfate crystals and cubic sodium chloride crystals embedded in an organic matrix; d) cubic sodium chloride crystals are dominant. In the unaffected area, no other crystals were detected different from the carbonate minerals forming the rock. These results are in accordance to which has already been published by the authors in granitic materials (Cámara et al 2014). Acknowledgements: to Geomateriales 2 programme (S2013/MIT-2914) funded by the Community of Madrid. Cámara B., Alvarez de Buergo, M.; Fort, R.; Ascaso, C. de los Rios, A.; Gomez-Heras, M. 2014. Another source of soluble salts in urban environments due to recent social behaviour pattern in historical centres. In: Science, Technology and Cultural Heritage (edited by M.A. Rogerio-Candelera), 89-94. CRC Press-Balkema, Taylor and Francis. ISBN 9781138027442 - CAT# K25502

  17. Spot protein-creatinine ratio and spot albumin-creatinine ratio in the assessment of pre-eclampsia: a diagnostic accuracy study with decision-analytic model-based economic evaluation and acceptability analysis.

    PubMed

    Waugh, Jason; Hooper, Richard; Lamb, Edmund; Robson, Stephen; Shennan, Andrew; Milne, Fiona; Price, Christopher; Thangaratinam, Shakila; Berdunov, Vladislav; Bingham, Jenn

    2017-10-01

    The National Institute for Health and Care Excellence (NICE) guidelines highlighted the need for 'large, high-quality prospective studies comparing the various methods of measuring proteinuria in women with new-onset hypertensive disorders during pregnancy'. The primary objective was to evaluate quantitative assessments of spot protein-creatinine ratio (SPCR) and spot albumin-creatinine ratio (SACR) in predicting severe pre-eclampsia (PE) compared with 24-hour urine protein measurement. The secondary objectives were to investigate interlaboratory assay variation, to evaluate SPCR and SACR thresholds in predicting adverse maternal and fetal outcomes and to assess the cost-effectiveness of these models. This was a prospective diagnostic accuracy cohort study, with decision-analytic modelling and a cost-effectiveness analysis. The setting was 36 obstetric units in England, UK. Pregnant women (aged ≥ 16 years), who were at > 20 weeks' gestation with confirmed gestational hypertension and trace or more proteinuria on an automated dipstick urinalysis. Women provided a spot urine sample for protein analysis (the recruitment sample) and were asked to collect a 24-hour urine sample, which was stored for secondary analysis. A further spot sample of urine was taken immediately before delivery. Outcome data were collected from hospital records. There were four index tests on a spot sample of urine: (1) SPCR test (conducted at the local laboratory); (2) SPCR test [conducted at the central laboratory using the benzethonium chloride (BZC) assay]; (3) SPCR test [conducted at the central laboratory using the pyrogallol red (PGR) assay]; and (4) SACR test (conducted at the central laboratory using an automated chemistry analyser). The comparator tests on 24-hour urine collection were a central test using the BZC assay and a central test using the PGR assay. The primary reference standard was the NICE definition of severe PE. Secondary reference standards were a clinician diagnosis of severe PE, which is defined as treatment with magnesium sulphate or with severe PE protocol; adverse perinatal outcome; one or more of perinatal or infant mortality, bronchopulmonary dysplasia, necrotising enterocolitis or grade III/IV intraventricular haemorrhage; and economic cost and outcomes. Health service data on service use and costs followed published economic models. In total, 959 women were available for primary analysis and 417 of them had severe PE. The diagnostic accuracy of the four assays on spot urine samples against the reference standards was similar. The three SPCR tests had sensitivities in excess of 90% at prespecified thresholds, with poor specificities and negative likelihood ratios of ≥ 0.1. The SACR test had a significantly higher sensitivity of 99% (confidence interval 98% to 100%) and lower specificity. Receiver operating characteristic (ROC) curves were similar (area under ROC curve between 0.87 and 0.89); the area under the central laboratory's SACR curve was significantly higher ( p  = 0.004). The central laboratory's SACR test was the most cost-effective option, generating an additional 0.03 quality-adjusted life-years at an additional cost of £45.07 compared with the local laboratory's SPCR test. The probabilistic analysis showed it to have a 100% probability of being cost-effective at the standard willingness-to-pay threshold recommended by NICE. Implementation of NICE guidelines has led to an increased intervention rate in the study population that affected recruitment rates and led to revised sample size calculations. Evidence from this clinical study does not support the recommendation of 24-hour urine sample collection in hypertensive pregnant women. The SACR test had better diagnostic performance when predicting severe pre-eclampsia. All four tests could potentially be used as rule-out tests for the NICE definition of severe PE. Testing SACR at a threshold of 8 mg/mmol should be studied as a 'rule-out' test of proteinuria. Current Controlled Trials ISRCTN82607486. This project was funded by the National Institute Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 21, No. 61. See the NIHR Journals Library website for further project information.

  18. Comprehensive analysis of pyrimidine metabolism in 450 children with unspecific neurological symptoms using high-pressure liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Schmidt, C; Hofmann, U; Kohlmüller, D; Mürdter, T; Zanger, U M; Schwab, M; Hoffmann, G F

    2005-01-01

    To evaluate the significance of inborn metabolic disorders of the pyrimidine degradation pathway, 450 children with unspecific neurological symptoms were comprehensively studied; 200 healthy children were recruited as controls. Uracil and thymine as well as their degradation products in urine were determined with an improved method based on reversed-phase HPLC coupled with electrospray ionization tandem mass spectrometry and detection by multiple-reaction monitoring using stable-isotope-labelled reference compounds as internal standards. From the results of the control group we established age-related reference ranges of all pyrimidine degradation products. In the patient group, two children with dihydropyrimidine dehydrogenase (DPYD) deficiency were identified; one of these was homozygous for the exon 14-skipping mutation of the DPYD gene. In addition, two patients with high uracil, dihydrouracil and beta-ureidopropionate were found to have ornithine transcarbamylase deficiency. In the urine of 9 patients, beta-alanine was markedly elevated owing to treatment with vigabatrin, an irreversible inhibitor of GABA transaminase, which interferes with beta-alanine breakdown. Four patients had exclusively high levels of beta-aminoisobutyrate (beta-AIB) due to a low activity of the D-beta-AIB-pyruvate aminotransferase, probably without clinical significance. In conclusion, quantitative investigation of pyrimidine metabolites in children with unexplained neurological symptoms, particularly epileptic seizures with or without psychomotor retardation, can be recommended as a helpful tool for diagnosis in clinical practice. Sensitive methods and age-related reference ranges enable the detection of partial enzyme deficiencies.

  19. Challenges in the indirect quantitation of acyl-glucuronide metabolites of a cardiovascular drug from complex biological mixtures in the absence of reference standards.

    PubMed

    Srinivasan, Karthik; Nouri, Parya; Kavetskaia, Olga

    2010-07-01

    This paper describes the quantitation of acyl-glucuronide metabolites (M26 and M5) of a cardiovascular-drug (torcetrapib) from monkey urine, in the absence of their reference standards. LC/MS/MS assays for M1 and M4 (aglycones of M26 and M5, respectively) were characterized from normal and base-treated urine, as their respective reference standards were available. The in vivo study samples containing M26 and M5 were treated with 1 n sodium hydroxide to hydrolyze them to their respective aglycones. The study samples were assayed for M1 and M4 before and after alkaline hydrolysis and the difference in the concentrations provided an estimate of the urinary levels of M26 and M5. Prior to the main sample analysis, conditions for alkaline hydrolysis of the glucuronides were optimized by incubating pooled study samples. During incubations, a prolonged increase in M4 levels over time was observed, which is inconsistent with the base-hydrolysis of an acyl-glucuronide (expected to hydrolyze rapidly). Possible interference of the metabolite M9 (an ether-glucuronide metabolite isobaric to M4) was investigated to explain this observation using chromatographic and wet-chemistry approaches. The strategies adopted herein established that the LC/MS/MS assay and our approach were reliable. The metabolite exposure was then correlated to toxicological observations to gain initial insights into the physiological role of these metabolites. Copyright (c) 2009 John Wiley & Sons, Ltd.

  20. [Renal excretion of total porphyrins and hippuric acid in rats].

    PubMed

    Gartzke, J; Burck, D

    1986-09-01

    The amounts of total porphyrins, hippuric acid and creatinine, excreted in urine by adult male Wistar rats, exhibited normal distributions for hippuric acid and creatinine, but a bimodal distribution for total porphyrins. This typical distribution of total porphyrins was still observed when creatinine was used as reference parameter. In biochemical and toxicological experiments in rats, the tested parameters should be therefore be investigated for homogeneity.

  1. [The biotransformation of fenetylline].

    PubMed

    Rücker, G; Neugebauer, M; Heiden, P G

    1988-04-01

    After oral administration of 3,7-dihydro-1,3-dimethyl-7-2 [(1-methyl-2-phenylethyl)-amino-ethyl]-1H-purine-2,6-dione (fenetylline, Captagon), 7 new metabolites could be detected in urine besides 4 known substances. The metabolites were identified by gas chromatography (GC) and by comparison of the mass spectra (MS) of metabolites with those of authentic reference compounds using a combined GC/MS method.

  2. An Assessment of Modafinil for Vestibular and Aviation-Related Effects

    DTIC Science & Technology

    2005-10-01

    Charlton and Cory Welch for editing and checking references; Ms. Anne Marie Michel for sheparding the urine through the analysis process . Lastly we wish to...superior performance during the sleep deprivation on the following tasks: reaction time task, mathematical processing , memory search, spatial... processing , unstable tracking, and grammatical reasoning. Baranski, Cian, Esquivie, Pigeau, and Raphel (1998) administered a cognitive test battery during a

  3. Determination of monobromobimane derivatives of phenylmercapturic and benzylmercapturic acids in urine by high-performance liquid chromatography and fluorimetry.

    PubMed

    Buratti, M; Brambilla, G; Fustinoni, S; Pellegrino, O; Pulviremti, S; Colombi, A

    2001-02-25

    A method was developed for the determination in human urine of S-phenylmercapturic (PMA) and S-benzylmercapturic (BMA) acids, metabolites respectively of benzene and toluene. PMA and BMA were determined, after alkaline hydrolysis, to give respectively thiophenol and benzylmercaptan, and coupling of the thiol-containing compounds with monobromobimane (MB), by reversed-phase HPLC on a diphenyl-silica bonded cartridge (100 x 4.6 mm I.D., 5 microm particle size) with fluorimetric detection. Wavelengths for excitation and emission were 375 and 480 nm, respectively. The recovery of PMA and BMA from spiked urines was >90% in the 10-500 microg/l range; the quantification limits were respectively 1 and 0.5 microg/l; day-to-day precision at 42 microg/l was C.V. <7%. The suitability of the proposed procedure for the biological monitoring of exposure to low-level airborne concentrations of benzene and toluene, was evaluated by analyzing the urinary excretion of PMA and BMA in subjects exposed to different sources of aromatic hydrocarbons, namely occupationally-unexposed referents (non-smokers, n=15; moderate smokers, n=8; mean number of cigarettes smoked per-day=17 cig/day) and non-smoker workers occupationally exposed to toluene in maintenance operations of rotogravure machines (non-smokers, n=17). Among referents, non-smokers showed values of PMA ranging from <1 to 4.6 microg/l and BMA from 1.0 to 10.4 microg/l; in smokers, PMA values ranging from 1.2 to 6.7 microg/l and BMA from 9.3 to 39.9 microg/l, were observed. In occupationally exposed non-smoker subjects, BMA median excretion value (23.6 microg/l) was higher than in non-smoker referents (3.5 microg/l) (P<0.001) and individual BMA values (y, microg/l) were associated and increased with airborne toluene concentration (x, mg/m3) according to the equation y=6.5+0.65x (r=0.69, P<0.01, n=17). The proposed analytical method appears to be a sensitive and specific tool for biological monitoring of low-level exposure to benzene and toluene mixtures in occupational and environmental toxicology laboratory.

  4. Stress Corrosion Evaluation of Various Metallic Materials for the International Space Station Water Recycling System

    NASA Technical Reports Server (NTRS)

    Torres, P. D.

    2015-01-01

    A stress corrosion evaluation was performed on Inconel 625, Hastelloy C276, titanium commercially pure (TiCP), Ti-6Al-4V, Ti-6Al-4V extra low interstitial, and Cronidur 30 steel as a consequence of a change in formulation of the pretreatment for processing the urine in the International Space Station Environmental Control and Life Support System Urine Processing Assembly from a sulfuric acid-based to a phosphoric acid-based solution. The first five listed were found resistant to stress corrosion in the pretreatment and brine. However, some of the Cronidur 30 specimens experienced reduction in load-carrying ability.

  5. Ground Test of the Urine Processing Assembly for Accelerations and Transfer Functions

    NASA Technical Reports Server (NTRS)

    Houston, Janice; Almond, Deborah F. (Technical Monitor)

    2001-01-01

    This viewgraph presentation gives an overview of the ground test of the urine processing assembly for accelerations and transfer functions. Details are given on the test setup, test data, data analysis, analytical results, and microgravity assessment. The conclusions of the tests include the following: (1) the single input/multiple output method is useful if the data is acquired by tri-axial accelerometers and inputs can be considered uncorrelated; (2) tying coherence with the matrix yields higher confidence in results; (3) the WRS#2 rack ORUs need to be isolated; (4) and future work includes a plan for characterizing performance of isolation materials.

  6. Self sufficient wireless transmitter powered by foot-pumped urine operating wearable MFC.

    PubMed

    Taghavi, M; Stinchcombe, A; Greenman, J; Mattoli, V; Beccai, L; Mazzolai, B; Melhuish, C; Ieropoulos, I A

    2015-12-10

    The first self-sufficient system, powered by a wearable energy generator based on microbial fuel cell (MFC) technology is introduced. MFCs made from compliant material were developed in the frame of a pair of socks, which was fed by urine via a manual gaiting pump. The simple and single loop cardiovascular fish circulatory system was used as the inspiration for the design of the manual pump. A wireless programmable communication module, engineered to operate within the range of the generated electricity, was employed, which opens a new avenue for research in the utilisation of waste products for powering portable as well as wearable electronics.

  7. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    PubMed

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  8. Recent developments in the field of environmental reference materials at the JRC Ispra.

    PubMed

    Muntau, H

    2001-06-01

    The production of reference materials for environmental analysis started in the Joint Research Centre at Ispra/Italy in 1972 with the objective of later certification by the BCR, but for obvious budget reasons only a fraction of the total production achieved at Ispra ever reached certification level, although all materials were produced according to the severe quality requirements requested for certified reference materials. Therefore, the materials not destinated to certification are in growing demand as inter-laboratory test materials and as laboratory reference materials, for internal quality control, e.g., by control charts. The history of reference material production within the Joint Research Centre is briefly reviewed and the latest additions described. New developments such as micro-scale reference materials intended for analytical methods requiring sample intakes at milligram or sub-milligram level and therefor not finding supply on the reference material market, and "wet" environmental reference materials, which meet more precisely the "real-world" environmental analysis conditions, are presented and the state-of-the-art discussed.

  9. Differentiating Calcium Oxalate and Hydroxyapatite Stones In Vivo Using Dual-Energy CT and Urine Supersaturation and pH Values

    PubMed Central

    Liu, Yu; Qu, Mingliang; Carter, Rickey E.; Leng, Shuai; Ramirez-Giraldo, Juan Carlos; Jaramillo, Giselle; Krambeck, Amy E.; Lieske, John C.; Vrtiska, Terri J.; McCollough, Cynthia H.

    2014-01-01

    Rationale and Objectives Knowledge of urinary stone composition can guide therapeutic intervention for patients with calcium oxalate (CaOx) or hydroxyapatite (HA) stones. In this study, we determined the accuracy of noninvasive differentiation of these two stone types using dual-energy CT (DECT) and urine supersaturation (SS) and pH values. Materials and Methods Patients who underwent clinically indicated DECT scanning for stone disease and subsequent surgical intervention were enrolled. Stone composition was determined using infrared spectroscopy. DECT images were processed using custom-developed software that evaluated the ratio of CT numbers between low- and high-energy images. Clinical information, including patient age, gender, and urine pH and supersaturation profile, was obtained from electronic medical records. Simple and multiple logistic regressions were used to determine if the ratio of CT numbers could discriminate CaOx from HA stones alone or in conjunction with urine supersaturation and pH. Results Urinary stones (CaOx n = 43, HA n = 18) from 61 patients were included in this study. In a univariate model, DECT data, urine SS-HA, and urine pH had an area under the receiver operating characteristic curve of 0.78 (95% confidence interval [CI] 0.66–0.91, P = .016), 0.76 (95%CI 0.61–0.91, P = .003), and 0.60 (95% CI 0.44–0.75, P = .20), respectively, for predicting stone composition. The combination of CT data and the urinary SS-HA had an area under the receiver operating characteristic curve of 0.79 (95%CI 0.66–0.92, P = .007) for correctly differentiating these two stone types. Conclusions DECT differentiated between CaOx and HA stones similarly to SS-HA, whereas pH was a poor discriminator. The combination of DECT and urine SS or pH data did not improve this performance. PMID:24200478

  10. Highly Sensitive Detection of Urinary Cadmium to Assess Personal Exposure

    PubMed Central

    Argun, Avni A.; Banks, Ashley; Merlen, Gwendolynne; Tempelman, Linda A.; Becker, Michael F.; Schuelke, Thomas; Dweik, Badawi

    2013-01-01

    A series of Boron-Doped Diamond (BDD) ultramicroelectrode arrays were fabricated and investigated for their performance as electrochemical sensors to detect trace level metals such as cadmium. The steady-state diffusion behavior of these sensors was validated using cyclic voltammetry followed by electrochemical detection of cadmium in water and in human urine to demonstrate high sensitivity (>200 μA/ppb/cm2) and low background current (<4 nA). When an array of ultramicroelectrodes was positioned with optimal spacing, these BDD sensors showed a sigmoidal diffusion behavior. They also demonstrated high accuracy with linear dose dependence for quantification of cadmium in a certified reference river water sample from the National Institute of Standards and Technology (NIST) as well as in a human urine sample spiked with 0.25–1 ppb cadmium. PMID:23561905

  11. Screening for basic drugs in equine urine using direct-injection differential-gradient LC-LC coupled to hybrid tandem MS/MS.

    PubMed

    Stanley, Shawn M R; Foo, Hsiao Ching

    2006-05-19

    A rapid, selective and robust direct-injection LC/hybrid tandem MS method has been developed for simultaneous screening of more than 250 basic drugs in the supernatant of enzyme hydrolysed equine urine. Analytes, trapped using a short HLB extraction column, are refocused and separated on a Sunfire C(18) analytical column using a controlled differential gradient generated by proportional dilution of the first column's eluent with water. Independent data acquisition (IDA) was configured to trigger a sensitive enhanced product ion (EPI) scan when a multiple reaction monitoring (MRM) survey scan signal exceeded the defined criteria. The decision on whether or not to report a sample as a positive result was based upon both the presence of a MRM response within the correct retention time range and a qualitative match between the EPI spectrum obtained and the corresponding reference standard. Ninety seven percent of the drugs targeted by this method met our detection criteria when spiked into urine at 100 ng/ml; 199 were found at 10 ng/ml, 83 at 1 ng/ml and 4 at 0.1 ng/ml.

  12. Gas chromatography-mass spectrometry profiles of urinary organic acids in healthy captive cheetahs (Acinonyx jubatus).

    PubMed

    Tordiffe, Adrian Stephen Wolferstan; van Reenen, Mari; Reyers, Fred; Mienie, Lodewyk Jacobus

    2017-04-01

    In captivity, cheetahs (Acinonyx jubatus) frequently suffer from several unusual chronic diseases that rarely occur in their free-ranging counterparts. In order to develop a better understanding of their metabolism and health we documented the urine organic acids of 41 apparently healthy captive cheetahs, in an untargeted metabolomic study, using gas chromatography-mass spectrometry. A total of 339 organic acids were detected and annotated. Phenolic compounds, thought to be produced by the anaerobic fermentation of aromatic amino acids in the distal colon, as well as their corresponding glycine conjugates, were present in high concentrations. The most abundant organic acids in the cheetahs' urine were an as yet unidentified compound and a novel cadaverine metabolite, tentatively identified as N 1 ,N 5 -dimethylpentane-1,5-diamine. Pantothenic acid and citramalic acid concentrations correlated negatively with age, while glutaric acid concentrations correlated positively with age, suggesting possible dysregulation of coenzyme A metabolism in older cheetahs. This study provides a baseline of urine organic acid reference values in captive cheetahs and suggests important avenues for future research in this species. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Inheritance of pericentric inversion in chromosome 7 through the three progenies and a newborn with congenital hydronephrosis diagnosed prenatally by fetal urine sampling.

    PubMed

    Demirhan, Osman; Ozcan, Kenan; Taştemir, Deniz; Demir, Cansun; Tunç, Erdal; Solğun, Hüseyin A; Güzel, Ali Irfan

    2008-01-01

    To report the inheritance of a pericentric inversion in chromosome 7 through the three progenies, congenital hydronephrosis, and recurrent miscarriages in an extended family. Case report. Medical Faculty of Cukurova University in Turkey. Referred by obstetrics and gynecology clinic. Fetal urine and lymphocytic karyotype. Chromosomal analysis from fetal urine and peripheral blood lymphocytes were performed according to standard cytogenetic methods. We assessed an extended family in which a large pericentric inversion in chromosome 7 is segregating; one of the three progenies with the karyotype 46,XY,inv(7)(p22;q22) was heterozygote for the inversion and presented with congenital hydronephrosis. His mother, mother's brother, grandfather, grandfather's brother, and his daughter were similar for the inversion. This case describes the further molecular characterization of these breakpoints on the short or long arm of chromosome 7(p22-q22). The inv(7) is also associated with fetal wastage and may be playing a role in the etiology of the family's miscarriages. These findings can be used in clinical genetics and may be an effective tool for reproductive guidance and genetic counseling.

  14. Pharmacokinetics of furagin, a new nitrofurantoin congener, on human volunteers.

    PubMed

    Männistö, P; Karttunen, P

    1979-06-01

    The human pharmacokinetics of a nitrofurantoin congener furagin was studied after a single oral dose of 200 mg and during a 9-day continuous treatment with a dose of 100 mg t.i.d. The same dose of nitrofurantoin served as a reference medication. In the acute cross-over phase food greatly speeded up and atropine somewhat retarded the absorption of furagin, but the total absorption remained virtually unchanged as judged from the unchanged AUC values. The furagin concentrations in serum remain several hours above the MIC concentrations of many pathogenic bacteria. Despite the high concentrations in serum, the urine levels of furagin were generally lower than those of nitrofurantoin. The 24 hr recoveries in urine were 8--13% for furagin and about 36% for nitrofurantoin. In the prolonged trial furagin was absorbed and excreted in the same way as in the acute trial. On the 9th day the concentrations in serum and urine were higher than on the first day. The urinary concentrations of both furagin and nitrofurantoin always remained well above the MIC values of the most susceptible bacteria. Several volunteers complained of nightly cramps in their calves after taking furagin for some days, otherwise the side effects were minimal.

  15. Evolution of GH secretion in urine during an in-patient slimming course in obese children.

    PubMed

    Lehingue, Y; Locard, E; Vivant, J F; Mounier, A; Serban, A; Remontet, L; Porquet, D; Joly, M O; Mamelle, N

    2000-03-01

    To estimate the change in GH excretion in urine (GH-U) during a slimming course, and if increased, to assess the components of the course related to the increase in obese children. Observational follow-up study of patients admitted for primary obesity to an in-patient slimming course lasting at least 10 weeks. 48 complete observations out of 54 consecutive pre-pubertal patients admitted to a paediatric centre for treatment of primary obesity (BMI greater than the 90th percentile of the national reference curves). GH excretion in urine by immunoradiometric assay, at entry and after 10 weeks, various anthropometric measurements, nutritional intake and departure from the prescribed diet, time spent in physical activity, sleep duration. A mean decrease of 0.90 standard deviations for BMI was accompanied by a 34% increase of GH-U. Time spent in physical activity was the only component of the course found to be related to the magnitude of GH-U increase. The results of this observational study confirm that GH-U is increased after a slimming course in children, and suggest that physical activity is a major contributor to the restoration of normal GH-U levels.

  16. Phase I metabolism of the recently emerged synthetic cannabinoid CUMYL-PEGACLONE and detection in human urine samples.

    PubMed

    Mogler, Lukas; Wilde, Maurice; Huppertz, Laura M; Weinfurtner, Georg; Franz, Florian; Auwärter, Volker

    2018-05-01

    Indole-, indazole-, or azaindole-based synthetic cannabinoids (SCs), bearing a cumyl substituent are a widespread, recreationally used subgroup of new psychoactive substances (NPS). The latest cumyl-derivative, CUMYL-PEGACLONE, emerged in December 2016 on the German drug market. The substance features a novel γ-carboline core structure, which is most likely synthesized to bypass generic legislative approaches to control SCs by prohibiting distinct core structures. Using liquid chromatography-tandem mass spectrometry and liquid chromatography-high resolution mass spectrometry techniques, the main in vivo phase I metabolites of this new substance were detected. A pooled human liver microsome assay was applied to generate in vitro reference spectra of CUMYL-PEGACLONE phase I metabolites. Additionally, 30 urine samples were investigated leading to 22 in vivo metabolites. A metabolite mono-hydroxylated at the γ-carbolinone core system and a metabolite with an additional carbonyl group at the pentyl side chain were evaluated as highly specific and sensitive markers to proof CUMYL-PEGACLONE uptake. Moreover, 3 immunochemical assays commonly used for SC screening in urine were tested for their capability of detecting the new drug but failed due to insufficient cross-reactivity. Copyright © 2018 John Wiley & Sons, Ltd.

  17. [Continuous challenges in Japanese forensic toxicology practice: strategy to address specific goals].

    PubMed

    Kageura, Mitsuyoshi

    2002-09-01

    In this paper, the status quo of forensic toxicology in Japan and the West is surveyed and a strategy to address future goals of Japanese forensic toxicology is proposed. Forensic toxicology in the West consists of three main areas--post-mortem forensic toxicology, human-performance forensic toxicology and forensic urine drug testing. In Japan, post-mortem forensic toxicology is practiced in university forensic medicine departments while most of the human-performance forensic toxicology is carried out in police laboratories. However, at least at present, strictly controlled workplace urine drug testing is not being performed, despite the abuse of drugs even by uniformed members of the National Defence Forces and police. For several years, the author has been introducing Western forensic toxicology guidelines and recommendations, translated into Japanese with the help of Western forensic toxicologists, to Japanese forensic toxicologists. Western forensic toxicology practice is at an advanced stage, whereas Japanese practice is in a critical condition and holds many problems awaiting solution, as exemplified by the urine drug testing in police laboratories. There is never any sample left for re-examination by the defence in all cases, though the initial volume of the urine sample available for examination is 30-50 ml. Only one organisation carries out everything from sampling to reporting and, in addition, the parent drug and its metabolites are not quantified. It is clear that the police laboratories do not work within good laboratory practice guidelines, nor do they have quality manuals or standard operating procedures manuals. A basic change in Japanese forensic toxicology practice is now essential. The author strongly recommends that, first of all, Japanese toxicologists should prepare forensic toxicology guidelines based on the Western models. The guidelines would progress the following objectives for forensic toxicology laboratories: 1) to have documented good laboratory practice standards; 2) to have a quality control system including a quality manual and standard operating procedures manual; 3) to have some degree of compulsion to implement quality assurance both through their own internal efforts and by appropriate remedial actions based on the results of an external proficiency testing scheme. For forensic toxicologists, the implications are that they should be: 1) responsible for ensuring that laboratory practices are performed under satisfactory conditions and 2) required to be certified as a forensic toxicology specialist in order to prove their forensic toxicology ability. For their part, governments should: 1) carry out administrative reforms related to forensic toxicology; 2) simplify the procedure for obtaining certified reference materials; 3) introduce a strict workplace urine drug testing programme for government employees, at least for those related to law enforcement. When all of these objectives have been realised, the specific goal will be achieved through which Japanese forensic toxicology is able, in practice, to fulfill its responsibility to society.

  18. [Measurement of the status of trace elements in cattle using liver biopsy samples].

    PubMed

    Ouweltjes, W; de Zeeuw, A C; Moen, A; Counotte, G H M

    2007-02-01

    Serum, plasma, or urine samples are usually used for the measurement of the trace elements copper; zinc, iron, selenium, because these samples are easy to obtain; however; these samples are not always appropriate. For example, it is not possible to measure molybdenum, the major antagonist of copper; in blood or urine. Therefore measurement of trace elements in liver tissue is considered the gold standard. For the assessment of selenium the method of choice remains determination of glutathion peroxidase in erythrocytes and for the assessment of magnesium determination of magnesium in urine. We determined the accuracy and repeatability of measuring trace elements in liver biopsies and whole liver homogenates. The levels of trace elements measured were similar in both preparations (92% agreement). Liver biopsy in live animals is a relatively simple procedure but not common in The Netherlands. Reference levels of trace elements, classified as too low, low, adequate, high, and too high, were established on the basis of our research and information in the literature. In a second study we investigated the practical aspects of obtaining liver tissue samples and their use. Samples were collected from cattle on a commercial dairy farm. Liver biopsy provided additional information to that obtained from serum and urine samples. We prepared a biopsy protocol and a test package, which we tested on 14 farms where an imbalance of trace minerals was suspected. Biopsy samples taken from 4 to 6 animals revealed extreme levels of trace elements.

  19. Estimation of Arsenic Intake from Drinking Water and Food (Raw and Cooked) in a Rural Village of Northern Chile. Urine as a Biomarker of Recent Exposure

    PubMed Central

    Diaz, Oscar Pablo; Arcos, Rafael; Tapia, Yasna; Pastene, Rubén; Velez, Dínoraz; Devesa, Vicenta; Montoro, Rosa; Aguilera, Valeska; Becerra, Miriam

    2015-01-01

    The aim of this study was to estimate both the contribution of drinking water and food (raw and cooked) to the total (t-As) and inorganic (i-As) arsenic intake and the exposure of inhabitants of Socaire, a rural village in Chile´s Antofagasta Region, by using urine as biomarker. The i-As intake from food and water was estimated using samples collected between November 2008 and September 2009. A 24-hour dietary recall questionnaire was given to 20 participants. Drinking water, food (raw and cooked) and urine samples were collected directly from the homes where the interviewees lived. The percentage of i-As/t-As in the drinking water that contributed to the total intake was variable (26.8–92.9). Cereals and vegetables are the food groups that contain higher concentrations of i-As. All of the participants interviewed exceeded the reference intake FAO/OMS (149.8 µg∙i-As·day−1) by approximately nine times. The concentration of t-As in urine in each individual ranged from 78 to 459 ng·mL−1. Estimated As intake from drinking water and food was not associated with total urinary As concentration. The results show that both drinking water and food substantially contribute to i-As intake and an increased exposure risk to adult residents in contaminated areas. PMID:26006131

  20. Uptake of pharmaceuticals by sorbent-amended struvite fertilisers recovered from human urine and their bioaccumulation in tomato fruit.

    PubMed

    de Boer, Marissa A; Hammerton, Michelle; Slootweg, J Chris

    2018-04-15

    Struvite precipitation is a well-documented method for recovering up to 98% of phosphorus from urine, which is one of the main nutrients in fertilizers besides nitrogen and potassium. Shortcomings of this process, however, are the low nitrogen recovery ratio and the possible uptake of pharmaceuticals from urine. In this work, the NH 4 + adsorbent materials biochar and zeolite are coupled with struvite precipitation to increase the N-recovery of struvite from 5.7% to 9.8%. Since nitrogen is one of the main nutrients in fertilisers, this increase is of significance for its potential commercial use. In addition, urine is spiked with pharmaceuticals to measure the consequential uptake in struvite-based fertilisers and crops afterwards. Five fertilisers are prepared by nutrient recovery from spiked urine using: (1) struvite crystallisation, (2) struvite crystallisation combined with N adsorption on zeolite, (3) struvite crystallisation combined with N adsorption on biochar, (4) N adsorption on zeolite without struvite crystallisation, and (5) N adsorption on biochar without struvite crystallisation. The fertiliser with the highest purity product and the lowest uptake of pharmaceuticals was struvite combined with zeolite. Next, the contaminated struvite-sorbent fertilisers are tested in a crop trial in which the bioaccumulation of pharmaceuticals in edible plant tissue (tomatoes) is measured. This bioaccumulation in tomato fruit biomass from each of the spiked fertilisers in the crop trial was found to be lower than 0.0003% in all cases, far below the acceptable daily intake (ADI) levels (750 kg of dry tomatoes should be consumed per day to reach the ADI limit). Consequently, the subsequent risk to human health from tomato fruit grown using urine derived struvite-sorbent fertilisers is found to be insignificant. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Validation of an ELISA Synthetic Cannabinoids Urine Assay

    PubMed Central

    Barnes, Allan J.; Spinelli, Eliani; Young, Sheena; Martin, Thomas M.; Klette, Kevin L.; Huestis, Marilyn A.

    2015-01-01

    Background Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug testing laboratories. We evaluated performance of the NMS JWH-018 direct ELISA kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. Materials/ Methods The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was utilized to screen 2492 urine samples with 5 and 10µg/L cutoffs. A fully validated LC-MS/MS method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25 and ±50% of cutoffs determined intra- and inter-plate imprecision around proposed cutoffs. Result The immunoassay was linear from 1–500µg/L with intra- and inter-plate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, co-administered drugs, over-the-counter medications or structurally similar compounds, and 19 of 73 individual, synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4% and 97.6% and 71.6%, 99.7% and 96.4%, with the 5 and 10µg/L urine cutoffs, respectively. Conclusion This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5µg/L urine cutoff. PMID:25706046

  2. Antifungal activity of a β-peptide in synthetic urine media: Toward materials-based approaches to reducing catheter-associated urinary tract fungal infections.

    PubMed

    Raman, Namrata; Lee, Myung-Ryul; Rodríguez López, Angélica de L; Palecek, Sean P; Lynn, David M

    2016-10-01

    Catheter-associated urinary tract infections (CAUTI) are the most common type of hospital-acquired infection, with more than 30 million catheters placed annually in the US and a 10-30% incidence of infection. Candida albicans forms fungal biofilms on the surfaces of urinary catheters and is the leading cause of fungal urinary tract infections. As a step toward new strategies that could prevent or reduce the occurrence of C. albicans-based CAUTI, we investigated the ability of antifungal β-peptide-based mimetics of antimicrobial peptides (AMPs) to kill C. albicans and prevent biofilm formation in synthetic urine. Many α-peptide-based AMPs exhibit antifungal activities, but are unstable in high ionic strength media and are easily degraded by proteases-features that limit their use in urinary catheter applications. Here, we demonstrate that β-peptides designed to mimic the amphiphilic helical structures of AMPs retain 100% of their structural stability and exhibit antifungal and anti-biofilm activity against C. albicans in a synthetic medium that mimics the composition of urine. We demonstrate further that these agents can be loaded into and released from polymer-based multilayer coatings applied to polyurethane, polyethylene, and silicone tubing commonly used as urinary catheters. Our results reveal catheters coated with β-peptide-loaded multilayers to kill planktonic fungal cells for up to 21days of intermittent challenges with C. albicans and prevent biofilm formation on catheter walls for at least 48h. These new materials and approaches could lead to advances that reduce the occurrence of fungal CAUTI. Catheter-associated urinary tract infections are the most common type of hospital-acquired infection. The human pathogen Candida albicans is the leading cause of fungal urinary tract infections, and forms difficult to remove 'biofilms' on the surfaces of urinary catheters. We investigated synthetic β-peptide mimics of natural antimicrobial peptides as an approach to kill C. albicans and prevent biofilm formation in media that mimics the composition of urine. Our results reveal these mimics to retain structural stability and activity against C. albicans in synthetic urine. We also report polymer-based approaches to the local release of these agents within urinary catheter tubes. With further development, these materials-based approaches could lead to advances that reduce the occurrence of fungal urinary tract infections. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  3. Improved sensitivity of the urine CAA lateral-flow assay for diagnosing active Schistosoma infections by using larger sample volumes.

    PubMed

    Corstjens, Paul L A M; Nyakundi, Ruth K; de Dood, Claudia J; Kariuki, Thomas M; Ochola, Elizabeth A; Karanja, Diana M S; Mwinzi, Pauline N M; van Dam, Govert J

    2015-04-22

    Accurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction. Centrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test. Implementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay. Larger sample input increased Sn of the UCAA assay to a level indicating 'true' infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.

  4. Identifying Urinary and Serum Exosome Biomarkers for Radiation Exposure Using a Data Dependent Acquisition and SWATH-MS Combined Workflow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulkarni, Shilpa; Koller, Antonius; Proteomics Shared Resource, Herbert Irving Comprehensive Cancer Center, New York, New York

    Purpose: Early and accurate assessment of radiation injury by radiation-responsive biomarkers is critical for triage and early intervention. Biofluids such as urine and serum are convenient for such analysis. Recent research has also suggested that exosomes are a reliable source of biomarkers in disease progression. In the present study, we analyzed total urine proteome and exosomes isolated from urine or serum for potential biomarkers of acute and persistent radiation injury in mice exposed to lethal whole body irradiation (WBI). Methods and Materials: For feasibility studies, the mice were irradiated at 10.4 Gy WBI, and urine and serum samples were collected 24more » and 72 hours after irradiation. Exosomes were isolated and analyzed using liquid chromatography mass spectrometry/mass spectrometry-based workflow for radiation exposure signatures. A data dependent acquisition and SWATH-MS combined workflow approach was used to identify significantly exosome biomarkers indicative of acute or persistent radiation-induced responses. For the validation studies, mice were exposed to 3, 6, 8, or 10 Gy WBI, and samples were analyzed for comparison. Results: A comparison between total urine proteomics and urine exosome proteomics demonstrated that exosome proteomic analysis was superior in identifying radiation signatures. Feasibility studies identified 23 biomarkers from urine and 24 biomarkers from serum exosomes after WBI. Urinary exosome signatures identified different physiological parameters than the ones obtained in serum exosomes. Exosome signatures from urine indicated injury to the liver, gastrointestinal, and genitourinary tracts. In contrast, serum showed vascular injuries and acute inflammation in response to radiation. Selected urinary exosomal biomarkers also showed changes at lower radiation doses in validation studies. Conclusions: Exosome proteomics revealed radiation- and time-dependent protein signatures after WBI. A total of 47 differentially secreted proteins were identified in urinary and serum exosomes. Together, these data showed the feasibility of defining biomarkers that could elucidate tissue-associated and systemic response caused by high-dose ionizing radiation. This is the first report using an exosome proteomics approach to identify radiation signatures.« less

  5. Preventive effects of the aqueous extract of Cichorium intybus L. flower on ethylene glycol-induced renal calculi in rats

    PubMed Central

    Emamiyan, Mahdieh Zaman; Vaezi, Gholamhassan; Tehranipour, Maryam; Shahrohkabadi, Khdije; Shiravi, Abdolhossein

    2018-01-01

    Objective: Urolithiasis remains a global problem. Despite the availability of numerous methods, no definite therapeutic agent has been yet introduced for the prevention or treatment of kidney stones. In this study, we evaluated the possible preventive effects of aqueous extract of Cichorium intybus L. (chicory) flowers on ethylene glycol-induced renal calculi in rats. Materials and Methods: A total of 24 Wistar rats were randomly divided into four groups and were treated for 30 days. Group A received drinking tap water, while groups B, C, and D were administered with 1% ethylene glycol for induction of calcium oxalate stone formation. Rats in groups C and D received intraperitoneal injections of the aqueous extract of chicory flowers (50 and 200 mg/kg, respectively) since the first day of the experiment. The urine volume, urine pH, and urinary levels of oxalate, citrate, calcium, uric acid, and creatinine as well as serum levels of calcium, uric acid, and creatinine were measured. After 30 days, the rats' kidneys were removed and prepared for histological evaluation of calcium oxalate deposits. One-way analysis of variance (ANOVA), followed by Tukey's test, was performed, using SPSS version 20. Results: The number of calcium oxalate crystals was significantly higher in group B (ethylene glycol-only treated animals), compared to group A (control), group C (50 mg/kg of aqueous extract), and group D (200 mg/kg of aqueous extract) (p<0.05). On day 30, the urine level of citrate, oxalate (p>0.05), and creatinine (p<0.05), as well as urine pH (p<0.05) decreased in groups C and D, compared to group B. Also, urine calcium level, urine uric acid (p>0.05), and urine volume (p<0.05) were higher in group D, compared to group B. In addition, the serum level of calcium, creatinine (p<0.05), and uric acid (p<0.001) decreased in groups C and D. Conclusion: The aqueous extract of chicory flower (50 mg/kg) could reduce the number of calcium oxalate deposits in the urine and reduce the level of serum parameters. PMID:29632848

  6. Development of magnetic molecularly imprinted polymers for solid phase extraction of cocaine and metabolites in urine before high performance liquid chromatography - tandem mass spectrometry.

    PubMed

    Sánchez-González, Juan; Jesús Tabernero, María; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2016-01-15

    A magnetic molecularly imprinted polymer (MMIP) has been synthesized and applied for cocaine (COC) and metabolites (benzoylecgonine, BZE; cocaethylene, CE; and ecgonine methyl ester, EME) recognition/pre-concentration in urine samples. The MMIP has been prepared using COC as a template molecule, ethylene dimethacrylate (EDMA) as a functional monomer, divinylbenzene (DVB) as a cross-linker, Fe3O4 magnetite as a magnetic component, and 2,2'-azobisisobutyronitrile (AIBN) as an initiator. The best results (MIP layer on the surface of the magnetic nanoparticles) and physical properties of the prepared MMIP were obtained when assisting the synthesis procedure with ultrasounds (325W, 37kHz, 30°C, 4h). After solid phase extraction (SPE) with the prepared adsorbent material, analytes were determined by high performance liquid chromatography - tandem mass spectrometry (HPLC-MS/MS). Variables affecting the SPE process (batch mode) were fully evaluated. Optimum retention of analytes (1.8mL of urine and 50mg of MMIP) was achieved by fixing the urine pH at 5.5 (use of a KH2PO4/NaOH, pH 5.5 buffer solution), and magnetic stirring (25°C, 700rpm) for 10min. Elution was performed by using 2mL of a dichloromethane/2-propanol/ammonium hydroxide (75:20:5) mixture under ultrasounds (325W, 35kHz, room temperature) for 5min. The method was validated according to the guidance for bioanalytical method validation of the US Department of Health and Human Services, Food and Drug Administration. The detection limits were in the range of 0.39-1.4ngL(-1). The relative standard deviations of intra- and inter-day tests ranged from 5 to 11% and from 3 to 11%, respectively. Analytical recoveries were in the range of 79-106% when spiking drug-free urine samples at three concentration levels. Good results were also obtained after analyzing an FDT +25% control material. The applicability of the method was proved for screening/quantifying COC, BZE, CE and EME in several samples from poly-drug abusers. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. [Different meanings of Long(stranguria) in medicaland historical books in Han Dynasty].

    PubMed

    Zhang, T L; Liu, Q Y

    2017-03-28

    The word " long (stranguria)" is seen both in historical and medical works in the Han Dynasty, but with much different meanings. In medical books, including Nei jing ( Inner Canon ), Wu shi er bing fang ( Prescriptions for Fifty - two Diseases ), and Wu wei yi jian ( Medical Bamboo slips of Wuwei ), Long refers to incontinence of urination. However, in historical books, Long is usually expressed as " pi long " , referring to different conditions, including lame, fatigue, and disability, all congenital or acquired renal deficient illness. It is also seen in unearthed documents as fei ji (disability) and " du long " , referring to congenital or postnatal severe diseases resulting in disability to do anything. Together with orphan, widow, widower, senility, and poverty without relatives for existence, all weak communities need to be supported and saved.

  8. Removal of gadolinium-based contrast agents: adsorption on activated carbon.

    PubMed

    Elizalde-González, María P; García-Díaz, Esmeralda; González-Perea, Mario; Mattusch, Jürgen

    2017-03-01

    Three carbon samples were employed in this work, including commercial (1690 m 2  g -1 ), activated carbon prepared from guava seeds (637 m 2  g -1 ), and activated carbon prepared from avocado kernel (1068 m 2  g -1 ), to study the adsorption of the following gadolinium-based contrast agents (GBCAs): gadoterate meglumine Dotarem®, gadopentetate dimeglumine Magnevist®, and gadoxetate disodium Primovist®. The activation conditions with H 3 PO 4 were optimized using a Taguchi methodology to obtain mesoporous materials. The best removal efficiency by square meter in a batch system in aqueous solution and model urine was achieved by avocado kernel carbon, in which mesoporosity prevails over microporosity. The kinetic adsorption curves were described by a pseudo-second-order equation, and the adsorption isotherms in the concentration range 0.5-6 mM fit the Freundlich equation. The chemical characterization of the surfaces shows that materials with a greater amount of phenolic functional groups adsorb the GBCA better. Adsorption strongly depends on the pH due to the combination of the following factors: contrast agent protonated forms and carbon surface charge. The tested carbon samples were able to adsorb 70-90% of GBCA in aqueous solution and less in model urine. This research proposes a method for the elimination of GBCA from patient urine before its discharge into wastewater.

  9. Identification of compounds in an anti-fibrosis Chinese medicine (Fufang Biejia Ruangan Pill) and its absorbed components in rat biofluids and liver by UPLC-MS.

    PubMed

    Dong, Qin; Qiu, Ling-Ling; Zhang, Cong-En; Chen, Long-Hu; Feng, Wu-Wen; Ma, Li-Na; Yan, Dan; Niu, Ming; Wang, Jia-Bo; Xiao, Xiao-He

    2016-07-15

    Liver fibrosis represents a major public health problem worldwide. To date, antifibrotic treatment of fibrosis still remains an unconquered area for western medicine. Fufang Biejia Ruangan Pill (FFBJ) is the first anti-fibrosis drug approved by the China State Food and Drug Administration, and has been demonstrated to have a good antifibrotic efficacy in China. However, the chemical constituents of FFBJ and the absorption and distribution of it in vivo remain unclear, which restricts its research on bioactive components identification and mechanisms of action. In this study, ultra-performance liquid chromatography/quadrupole-time-of-flight mass spectrometry (UPLC/Q-TOF-MS) combined with ultra-performance liquid chromatography/triple quadrupole mass spectrometry (UPLC/QqQ-MS) was applied to identify compounds in FFBJ and its absorbed components in rat serum, liver and urine samples after intragastric administration of FFBJ. As a result, a total of 32 Chinese material medica components including organic acids, terpenoids, flavonoids, phenylpropanoids and alkaloids, were identified or tentatively characterized, while the distribution of 10 prototype compounds in rat serum, liver and urine were discovered. The identified constituents in FFBJ and the distribution of prototype compounds in rat serum, liver and urine are help for understanding the material bases of its therapeutic effects. Copyright © 2016. Published by Elsevier B.V.

  10. Detection of monohydroxylated polycyclic aromatic hydrocarbons in urine and particulate matter using LC separations coupled with integrated SPE and fluorescence detection or coupled with high-resolution time-of-flight mass spectrometry.

    PubMed

    Lintelmann, Jutta; Wu, Xiao; Kuhn, Evelyn; Ritter, Sebastian; Schmidt, Claudia; Zimmermann, Ralf

    2018-05-01

    A high-performance liquid chromatographic (HPLC) method with integrated solid-phase extraction for the determination of 1-hydroxypyrene and 1-, 2-, 3-, 4- and 9-hydroxyphenanthrene in urine was developed and validated. After enzymatic treatment and centrifugation of 500 μL urine, 100 μL of the sample was directly injected into the HPLC system. Integrated solid-phase extraction was performed on a selective, copper phthalocyanine modified packing material. Subsequent chromatographic separation was achieved on a pentafluorophenyl core-shell column using a methanol gradient. For quantification, time-programmed fluorescence detection was used. Matrix-dependent recoveries were between 94.8 and 102.4%, repeatability and reproducibility ranged from 2.2 to 17.9% and detection limits lay between 2.6 and 13.6 ng/L urine. A set of 16 samples from normally exposed adults was analyzed using this HPLC-fluorescence detection method. Results were comparable with those reported in other studies. The chromatographic separation of the method was transferred to an ultra-high-performance liquid chromatography pentafluorophenyl core-shell column and coupled to a high-resolution time-of-flight mass spectrometer (HR-TOF-MS). The resulting method was used to demonstrate the applicability of LC-HR-TOF-MS for simultaneous target and suspect screening of monohydroxylated polycyclic aromatic hydrocarbons in extracts of urine and particulate matter. Copyright © 2018 John Wiley & Sons, Ltd.

  11. 21 CFR 58.195 - Retention of records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... specimens (except those specimens obtained from mutagenicity tests and wet specimens of blood, urine, feces, and biological fluids), samples of test or control articles, and specially prepared material, which are relatively fragile and differ markedly in stability and quality during storage, shall be retained...

  12. Metabolism of androsta-1,4,6-triene-3,17-dione and detection by gas chromatography/mass spectrometry in doping control.

    PubMed

    Parr, Maria K; Fusshöller, Gregor; Schlörer, Nils; Opfermann, Georg; Piper, Thomas; Rodchenkov, Grigory; Schänzer, Wilhelm

    2009-01-01

    The urinary metabolism of the irreversible aromatase inhibitor androsta-1,4,6-triene-3,17-dione was investigated. It is mainly excreted unchanged and as its 17beta-hydroxy analogue. For confirmation, 17beta-hydroxyandrosta-1,4,6-trien-3-one was synthesized and characterized by nuclear magnetic resonance (NMR) in addition to the parent compound. In addition, several reduced metabolites were detected in the post-administration urines, namely 17beta-hydroxyandrosta-1,4-dien-3-one (boldenone), 17beta-hydroxy-5beta-androst-1-en-3-one (boldenone metabolite), 17beta-hydroxyandrosta-4,6-dien-3-one, and androsta-4,6-diene-3,17-dione. The identification was performed by comparison of the metabolites with reference material utilizing gas chromatography/mass spectrometry (GC/MS) of the underivatized compounds and GC/MS and GC/tandem mass spectrometry (MS/MS) of their trimethylsilyl (TMS) derivatives. Alterations in the steroid profile were also observed, most obviously in the androsterone/testosterone ratio. Even if not explicitly listed, androsta-1,4,6-triene-3,17-dione is classified as a prohibited substance in sports by the World Anti-Doping Agency (WADA) due to its aromatase-inhibiting properties. In 2006 three samples from human routine sports doping control tested positive for metabolites of androsta-1,4,6-triene-3,17-dione. The samples were initially found suspicious for the boldenone metabolite 17beta-hydroxy-5beta-androst-1-en-3-one. Since metabolites of androst-4-ene-3,6,17-trione were also present in the urine samples, it is presumed that these findings were due to the administration of a product like 'Novedex Xtreme', which could be easily obtained from the sport supplement market. Copyright (c) 2008 John Wiley & Sons, Ltd.

  13. Laboratory diagnostics of chronic kidney disease in Croatia: state of the art

    PubMed Central

    Honović, Lorena; Matica, Jasminka; Knežević, Branka; Vojak, Sanela Šimić

    2015-01-01

    Introduction Early identification and management of chronic kidney disease (CKD) is highly cost-effective and can reduce the risk of kidney failure progression and cardiovascular disease. In 2014, the Joint Croatian Working Group (JCWG) for laboratory diagnostic of CKD on the behalf of Croatian society of medical biochemistry and laboratory medicine (CSMBLM) and Croatian chamber of medical biochemists (CCMB) conducted a survey across Croatian medical-biochemistry laboratories to assess the current practice in this area of laboratory medicine. The aim of this study was to present the data collected through the survey and to give insight about laboratory diagnostics of chronic kidney disease in Croatia. Materials and methods An invitation to participate in the survey was sent to all Croatian medical-biochemistry laboratories (N = 196). The questionnaire was designed in a form of questions and statements, with possible multiple answers, comprising 24 questions. Results The response rate was 80/196 (40.8%). 39 answers were from primary medical-biochemistry laboratories. 31/78 (0.40) laboratories measure creatinine with non-standardized method (uncompensated Jaffe method). 58/78 (0.74) of laboratories that measure creatinine do not report eGFR values. Similar number of laboratories (58/80, 0.73) do not measure urine albumin or protein. Conclusions There is a large heterogeneity among Croatian laboratories regarding measuring methods, reporting units and reference intervals (cut-off values), both for creatinine and urine albumin or protein. The two key prerequisites for CKD screening, automatic reporting of eGFR and albuminuria or proteinuria assessment, are not implemented nationwide. There is a need for harmonization in laboratory diagnostics of CKD in Croatia. PMID:25672470

  14. A pilot plant two-phase anaerobic digestion system for bioenergy recovery from swine wastes and garbage.

    PubMed

    Feng, Chuanping; Shimada, Sadoru; Zhang, Zhenya; Maekawa, Takaaki

    2008-01-01

    A pilot plant bioenergy recovery system from swine waste and garbage was constructed. A series of experiments was performed using swine feces (SF); a mixture of swine feces and urine (MSFU); a mixture of swine feces, urine and garbage (MSFUG); garbage and a mixture of urine and garbage (AUG). The system performed well for treating the source materials at a high organic loading rate (OLR) and short hydraulic retention time (HRT). In particular, the biogas production for the MSFUG was the highest, accounting for approximately 865-930 L kg(-1)-VS added at the OLR of 5.0-5.3 kg-VS m(-3) day(-1) and the HRT of 9 days. The removal of VS was 67-75%, and that of COD was 73-74%. Therefore, co-digestion is a promising method for the recovery of bioenergy from swine waste and garbage. Furthermore, the results obtained from this study provide fundamental information for scaling up a high-performance anaerobic system in the future.

  15. Work Environment Factors and Their Influence on Urinary Chromium Levels in Informal Electroplating Workers

    NASA Astrophysics Data System (ADS)

    Setyaningsih, Yuliani; Husodo, Adi Heru; Astuti, Indwiani

    2018-02-01

    One of the informal sector which absorbs labor was electroplating business. This sector uses chromium as coating material because it was strong, corrosion resistant and strong. Nonetheless hexavalent chromium is highly toxic if inhaled, swallowed and contact with skin. Poor hygiene, the lack of work environment factors and sanitation conditions can increase the levels of chromium in the body. This aimed of this study was to analyze the association between work environment factors and levels of urinary chromium in informal electroplating worker. A Purposive study was conducted in Tegal Central Java. The research subjects were 66 male workers. Chi Square analysis was used to establish an association between work environment factors and level of urinary chromium. There is a relationship between heat stress and wind direction to the chromium levels in urine (p <0.05), but there is no relationship between humidity and levels of chromium in the urine (p> 0.05). This explains that work environment factors can increase chromium levels in the urine of informal electroplating workers.

  16. The diagnosis of urinary tract infections in young children (DUTY): protocol for a diagnostic and prospective observational study to derive and validate a clinical algorithm for the diagnosis of UTI in children presenting to primary care with an acute illness.

    PubMed

    Downing, Harriet; Thomas-Jones, Emma; Gal, Micaela; Waldron, Cherry-Ann; Sterne, Jonathan; Hollingworth, William; Hood, Kerenza; Delaney, Brendan; Little, Paul; Howe, Robin; Wootton, Mandy; Macgowan, Alastair; Butler, Christopher C; Hay, Alastair D

    2012-07-19

    Urinary tract infection (UTI) is common in children, and may cause serious illness and recurrent symptoms. However, obtaining a urine sample from young children in primary care is challenging and not feasible for large numbers. Evidence regarding the predictive value of symptoms, signs and urinalysis for UTI in young children is urgently needed to help primary care clinicians better identify children who should be investigated for UTI. This paper describes the protocol for the Diagnosis of Urinary Tract infection in Young children (DUTY) study. The overall study aim is to derive and validate a cost-effective clinical algorithm for the diagnosis of UTI in children presenting to primary care acutely unwell. DUTY is a multicentre, diagnostic and prospective observational study aiming to recruit at least 7,000 children aged before their fifth birthday, being assessed in primary care for any acute, non-traumatic, illness of ≤ 28 days duration. Urine samples will be obtained from eligible consented children, and data collected on medical history and presenting symptoms and signs. Urine samples will be dipstick tested in general practice and sent for microbiological analysis. All children with culture positive urines and a random sample of children with urine culture results in other, non-positive categories will be followed up to record symptom duration and healthcare resource use. A diagnostic algorithm will be constructed and validated and an economic evaluation conducted.The primary outcome will be a validated diagnostic algorithm using a reference standard of a pure/predominant growth of at least >103, but usually >105 CFU/mL of one, but no more than two uropathogens.We will use logistic regression to identify the clinical predictors (i.e. demographic, medical history, presenting signs and symptoms and urine dipstick analysis results) most strongly associated with a positive urine culture result. We will then use economic evaluation to compare the cost effectiveness of the candidate prediction rules. This study will provide novel, clinically important information on the diagnostic features of childhood UTI and the cost effectiveness of a validated prediction rule, to help primary care clinicians improve the efficiency of their diagnostic strategy for UTI in young children.

  17. The diagnosis of urinary tract infections in young children (DUTY): protocol for a diagnostic and prospective observational study to derive and validate a clinical algorithm for the diagnosis of UTI in children presenting to primary care with an acute illness

    PubMed Central

    2012-01-01

    Background Urinary tract infection (UTI) is common in children, and may cause serious illness and recurrent symptoms. However, obtaining a urine sample from young children in primary care is challenging and not feasible for large numbers. Evidence regarding the predictive value of symptoms, signs and urinalysis for UTI in young children is urgently needed to help primary care clinicians better identify children who should be investigated for UTI. This paper describes the protocol for the Diagnosis of Urinary Tract infection in Young children (DUTY) study. The overall study aim is to derive and validate a cost-effective clinical algorithm for the diagnosis of UTI in children presenting to primary care acutely unwell. Methods/design DUTY is a multicentre, diagnostic and prospective observational study aiming to recruit at least 7,000 children aged before their fifth birthday, being assessed in primary care for any acute, non-traumatic, illness of ≤ 28 days duration. Urine samples will be obtained from eligible consented children, and data collected on medical history and presenting symptoms and signs. Urine samples will be dipstick tested in general practice and sent for microbiological analysis. All children with culture positive urines and a random sample of children with urine culture results in other, non-positive categories will be followed up to record symptom duration and healthcare resource use. A diagnostic algorithm will be constructed and validated and an economic evaluation conducted. The primary outcome will be a validated diagnostic algorithm using a reference standard of a pure/predominant growth of at least >103, but usually >105 CFU/mL of one, but no more than two uropathogens. We will use logistic regression to identify the clinical predictors (i.e. demographic, medical history, presenting signs and symptoms and urine dipstick analysis results) most strongly associated with a positive urine culture result. We will then use economic evaluation to compare the cost effectiveness of the candidate prediction rules. Discussion This study will provide novel, clinically important information on the diagnostic features of childhood UTI and the cost effectiveness of a validated prediction rule, to help primary care clinicians improve the efficiency of their diagnostic strategy for UTI in young children. PMID:22812651

  18. Comprehensive solid-phase extraction of multitudinous bioactive peptides from equine plasma and urine for doping detection.

    PubMed

    Guan, Fuyu; Robinson, Mary A

    2017-09-08

    The ability to analyze biological samples for multitudinous exogenous peptides with a single analytical method is desired for doping control in horse racing. The key to achieving this goal is the capability of extracting all target peptides from the sample matrix. In the present study, theory of mixed-mode solid-phase extraction (SPE) of peptides from plasma is described, and a generic mixed-mode SPE procedure has been developed for recovering multitudinous exogenous peptides with remarkable sequence diversity, from equine plasma and urine in a single procedure. Both the theory and the developed SPE procedure have led to the development of a novel analytical method for comprehensive detection of multitudinous bioactive peptides in equine plasma and urine using liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS). Thirty nine bioactive peptides were extracted with strong anion-exchange mixed-mode SPE sorbent, separated on a reversed-phase C 18 column and detected by HRMS and data-dependent tandem mass spectrometry. The limit of detection (LOD) was 10-50 pg mL -1 in plasma for most of the peptides and 100 pg mL -1 for the remaining. For urine, LOD was 20-400 pg mL -1 for most of the peptides and 1-4 ng mL -1 for the others. In vitro degradation of the peptides in equine plasma and urine was examined at ambient temperature; the peptides except those with a D-amino acid at position 2 were unstable not only in plasma but also in urine. The developed method was successful in analysis of plasma and urine samples from horses administered dermorphin. Additionally, dermorphin metabolites were identified in the absence of reference standards. The developed SPE procedure and LC-HRMS method can theoretically detect virtually all peptides present at a sufficient concentration in a sample. New peptides can be readily included in the method to be detected without method re-development. The developed method also generates such data that can be retrospectively analyzed for peptides unknown at the time of sample analysis. It is the first generic analytical method for comprehensive detection of multitudinous exogenous peptides in biological samples, to the authors' knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Astronaut Bones: Stable Calcium Isotopes in Urine as a Biomarker of Bone Mineral Balance

    NASA Astrophysics Data System (ADS)

    Skulan, J.; Gordon, G. W.; Romaniello, S. J.; Anbar, A. D.; Smith, S. M.; Zwart, S.

    2016-12-01

    Bone loss is a common health concern, in conditions ranging from osteoporosis to cancer. Bone loss due to unloading is also an important health issue for astronauts. We demonstrate stable calcium isotopes, a tool developed in geochemistry, are capable of detecting real-time quantitative changes in net bone mineral balance (BMB) using serum and urine [1]. We validated this technique by comparing with DEXA and biomarker data in subjects during bed rest, a ground-based analog of space flight effects [2-4]. We now apply this tool to assess changes in astronauts' BMB before, during and after 4-6 month space missions. There is stable isotope fractionation asymmetry between bone formation and resorption. During bone formation there is a mass-dependent preference for "lighter" calcium isotopes to be removed from serum and incorporated into bone mineral. During bone resorption, there is no measurable isotopic discrimination between serum and bone. Hence, when bone formation rates exceed that of resorption, serum and urine become isotopically "heavy" due to the sequestration of "light" calcium in bone. Conversely, when bone resorption exceeds bone formation, serum and urine become isotopically "light" due to the release of the sequestered light calcium from bone. We measured Ca isotopes in urine of thirty International Space Station astronauts. Average Ca isotope values in astronauts' urine shift isotopically lighter during microgravity, consistent with negative net BMB. Within a month of return to Earth, astronauts returned to within error of their δ44Ca value prior to departure. Urine samples from astronauts testing bone loss countermeasures showed bisphosphonates provide a viable pharmacological countermeasure. Some, but not all, individuals appear able to resist bone loss through diet and intensive resistive exercise alone. This is a promising new technique for monitoring BMB in astronauts, and hopefully someday on the way to/from Mars, this also has important clinical applications for human health and terrestrial medicine [5]. REFERENCES [1] Morgan, J.L. et al (2011) Anal Chem 83, 6956-6962. [2] Skulan, J.L. et al. (2007) Clin Chem 53, 1155-1158. [3] Morgan, J.L. et al (2012) PNAS 109, 9989-9994. [4] Channon, M.B. et al (2015) Bone 77, 69-74. [5] Gordon, G.W. et al (2014) Leukemia 28, 2112-2115.

  20. A systematic review and meta-analysis of the diagnostic accuracy of point-of-care tests for the detection of hyperketonemia in dairy cows.

    PubMed

    Tatone, Elise H; Gordon, Jessica L; Hubbs, Jessie; LeBlanc, Stephen J; DeVries, Trevor J; Duffield, Todd F

    2016-08-01

    Several rapid tests for use on farm have been validated for the detection of hyperketonemia (HK) in dairy cattle, however the reported sensitivity and specificity of each method varies and no single study has compared them all. Meta-analysis of diagnostic test accuracy is becoming more common in human medical literature but there are few veterinary examples. The objective of this work was to perform a systematic review and meta-analysis to determine the point-of-care testing method with the highest combined sensitivity and specificity, the optimal threshold for each method, and to identify gaps in the literature. A comprehensive literature search resulted in 5196 references. After removing duplicates and performing relevance screening, 23 studies were included for the qualitative synthesis and 18 for the meta-analysis. The three index tests evaluated in the meta-analysis were: the Precision Xtra(®) handheld device measuring beta-hydroxybutyrate (BHB) concentration in whole blood, and Ketostix(®) and KetoTest(®) semi-quantitative strips measuring the concentration of acetoacetate in urine and BHB in milk, respectively. The diagnostic accuracy of the 3 index tests relative to the reference standard measurement of BHB in serum or whole blood between 1.0-1.4mmol/L was compared using the hierarchical summary receiver operator characteristic (HSROC) method. Subgroup analysis was conducted for each index test to examine the accuracy at different thresholds. The impact of the reference standard threshold, the reference standard method, the prevalence of HK in the population, the primary study source and risk of bias of the primary study was explored using meta-regression. The Precision Xtra(®) device had the highest summary sensitivity in whole blood BHB at 1.2mmol/L, 94.8% (CI95%: 92.6-97.0), and specificity, 97.5% (CI95%: 96.9-98.1). The threshold employed (1.2-1.4mmol/L) did not impact the diagnostic accuracy of the test. The Ketostix(®) and KetoTest(®) strips had the highest summary sensitivity and specificity when the trace and weak positive thresholds were used, respectively. Controlling for the source of publication, HK prevalence and reference standard employed did not impact the estimated sensitivity and specificity of the tests. Including only peer-reviewed studies reduced the number of primary studies evaluating the Precision Xtra(®) by 43% and Ketostix(®) by 33%. Diagnosing HK with blood, urine or milk are valid options, however, the diagnostic inaccuracy of urine and milk should be considered when making economic and treatment decisions. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Methods to improve routine bioassay monitoring for freshly separated, poorly transported plutonium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bihl, D.E.; Lynch, T.P.; Carbaugh, E.H.

    1988-09-01

    Several human cases involving inhalation of plutonium oxide at Hanford have shown clearance half-times from the lung that are much longer than the 500-day half-time recommended for class Y plutonium in Publication 30 of the International Commission on Radiological Protection(ICRP). The more tenaciously retained material is referred to as super class Y plutonium. The ability to detect super class Y plutonium by current routine bioassay measurements is shown to be poor. Pacific Northwest Laboratory staff involved in the Hanford Internal Dosimetry Program investigated four methods to se if improvements in routine monitoring of workers for fresh super class Y plutoniummore » are feasible. The methods were lung counting, urine sampling, fecal sampling, and use of diethylenetriaminepentaacetate (DTPA) to enhance urinary excretion. Use of DTPA was determined to be not feasible. Routine fecal sampling was found to be feasible but not recommended. Recommendations were made to improve the detection level for routine annual urinalysis and routine annual lung counting. 12 refs., 9 figs., 7 tabs.« less

  2. New concept for treating female stress urinary incontinence with radiofrequency

    PubMed Central

    Lordelo, Patrícia; Boas, Andrea Vilas; Sodré, Danielle; Lemos, Amanda; Tozetto, Sibele; Brasil, Cristina

    2017-01-01

    ABSTRACT Purpose: To evaluate the clinical response and adverse effects of radiofrequency on the urethral meatus in the treatment of stress urinary incontinence in women. Materials and Methods: This phase one study included ten women with Stress Urinary Incontinence (SUI). The evaluation consisted of 1 hour Pad tests to quantify urine loss and to assess the degree of procedure satisfaction by using the Likert scale. To evaluate safety, we observed the number of referred side effects. Results: Average age was 53.10 years±7.08 years. In assessing the final Pad Test, 70% showed a reduction and 30% a worsening of urinary loss. Using the Pad Test one month later, there was a reduction in all patients (p=0.028). The degree of satisfaction was 90% and no side effects have been observed. One patient reported burning sensation. Conclusion: The treatment of SUI with radiofrequency on the urethral meatus has no adverse effects, being a low risk method that reduces urinary loss in women. However, to increase the validity of the study, larger clinical trials are warranted. PMID:28727373

  3. Toxicological importance of human biomonitoring of metallic and metalloid elements in different biological samples.

    PubMed

    Gil, F; Hernández, A F

    2015-06-01

    Human biomonitoring has become an important tool for the assessment of internal doses of metallic and metalloid elements. These elements are of great significance because of their toxic properties and wide distribution in environmental compartments. Although blood and urine are the most used and accepted matrices for human biomonitoring, other non-conventional samples (saliva, placenta, meconium, hair, nails, teeth, breast milk) may have practical advantages and would provide additional information on health risk. Nevertheless, the analysis of these compounds in biological matrices other than blood and urine has not yet been accepted as a useful tool for biomonitoring. The validation of analytical procedures is absolutely necessary for a proper implementation of non-conventional samples in biomonitoring programs. However, the lack of reliable and useful analytical methodologies to assess exposure to metallic elements, and the potential interference of external contamination and variation in biological features of non-conventional samples are important limitations for setting health-based reference values. The influence of potential confounding factors on metallic concentration should always be considered. More research is needed to ascertain whether or not non-conventional matrices offer definitive advantages over the traditional samples and to broaden the available database for establishing worldwide accepted reference values in non-exposed populations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Familial forms of diabetes insipidus: clinical and molecular characteristics.

    PubMed

    Babey, Muriel; Kopp, Peter; Robertson, Gary L

    2011-07-05

    Over the past two decades, the genetic and molecular basis of familial forms of diabetes insipidus has been elucidated. Diabetes insipidus is a clinical syndrome characterized by the excretion of abnormally large volumes of diluted urine (polyuria) and increased fluid intake (polydipsia). The most common type of diabetes insipidus is caused by lack of the antidiuretic hormone arginine vasopressin (vasopressin), which is produced in the hypothalamus and secreted by the neurohypophysis. This type of diabetes insipidus is referred to here as neurohypophyseal diabetes insipidus. The syndrome can also result from resistance to the antidiuretic effects of vasopressin on the kidney, either at the level of the vasopressin 2 receptor or the aquaporin 2 water channel (which mediates the re-absorption of water from urine), and is referred to as renal or nephrogenic diabetes insipidus. Differentiation between these two types of diabetes insipidus and primary polydipsia can be difficult owing to the existence of partial as well as complete forms of vasopressin deficiency or resistance. Seven different familial forms of diabetes insipidus are known to exist. The clinical presentation, genetic basis and cellular mechanisms responsible for them vary considerably. This information has led to improved methods of differential diagnosis and could provide the basis of new forms of therapy.

  5. Pharmacokinetics and biodegradation of chitosan in rats

    NASA Astrophysics Data System (ADS)

    Li, Hui; Jiang, Zhiwen; Han, Baoqin; Niu, Shuyi; Dong, Wen; Liu, Wanshun

    2015-10-01

    Chitosan, an excellent biomedical material, has received a widespread in vivo application. In contrast, its metabolism and distribution once being implanted were less documented. In this study, the pharmacokinetics and biodegradation of fluorescein isothiocyanate (FITC) labeled and muscle implantation administrated chitosan in rats were investigated with fluorescence spectrophotometry, histological assay and gel chromatography. After implantation, chitosan was degraded gradually during its distribution to diverse organs. Among the tested organs, liver and kidney were found to be the first two highest in chitosan content, which was followed by heart, brain and spleen. Urinary excretion was believed to be the major pathway of chitosan elimination, yet 80% of chitosan administered to rats was not trackable in their urine. This indicated that the majority of chitosan was degraded in tissues. In average, the molecular weight of the degradation products of chitosan in diverse organs and urine was found to be <65 kDa. This further confirmed the in vivo degradation of chitosan. Our findings provided new evidences for the intensive and safe application of chitosan as a biomedical material.

  6. Effect of a Low Iodine Diet vs. Restricted Iodine Diet on Postsurgical Preparation for Radioiodine Ablation Therapy in Thyroid Carcinoma Patients

    PubMed Central

    Lim, Chi Young; Kim, Jung-Yeon; Yoon, Mi-Jin; Chang, Hang Seok; Park, Cheong Soo

    2015-01-01

    Purpose The radioiodine ablation therapy is required for patients who underwent a total thyroidectomy. Through a comparative review of a low iodine diet (LID) and a restricted iodine diet (RID), the study aims to suggest guidelines that are suitable for the conditions of Korea. Materials and Methods The study was conducted with 101 patients. With 24-hour urine samples from the patients after a 2-week restricted diet and after a 4-week restricted diet, the amount of iodine in the urine was estimated. The consumed radioiodine amounts for 2 hours and 24 hours were calculated. Results This study was conducted with 47 LID patients and 54 RID patients. The amounts of iodine in urine, the 2-week case and 4-week case for each group showed no significant differences. The amounts of iodine in urine between the two groups were both included in the range of the criteria for radioiodine ablation therapy. Also, 2 hours and 24 hours radioiodine consumption measured after 4-week restrictive diet did not show statistical differences between two groups. Conclusion A 2-week RID can be considered as a type of radioiodine ablation therapy after patients undergo a total thyroidectomy. PMID:26069126

  7. Genetic DNA profile in urine and hair follicles from patients who have undergone allogeneic hematopoietic stem cell transplantation.

    PubMed

    Santurtún, Ana; Riancho, José A; Santurtún, Maite; Richard, Carlos; Colorado, M Mercedes; García Unzueta, Mayte; Zarrabeitia, María T

    2017-09-01

    Biological samples from patients who have undergone allogeneic hematopoietic stem cell transplantation (HSCT) constitute a challenge for individual identification. In this study we analyzed the genetic profiles (by the amplification of 15 autosomic STRs) of HSCT patients found in different types of samples (blood, hair and urine) that may be the source of DNA in civil or criminal forensic cases. Our results show that while in hair follicles the donor component was not detected in any patient, thus being a reliable source of biological material for forensic identification, mixed chimerism was detected in urine samples from all patient, and no correlation was found between the time elapsed from the transplant and the percentage of chimerism. These results certainly have practical implications if the urine is being considered as a source of DNA for identification purposes in HSTC patients. Moreover, taking into consideration that chimerism was found not only in patients with leukocyturia (given the hematopoietic origin of leukocytes, this was expected), but also in those without observable leukocytes in the sediment, we conclude that an alternative source or sources of donor DNA must be implicated. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  8. Detection of Synthetic Testosterone Use by Novel Comprehensive Two-Dimensional Gas Chromatography Combustion Isotope Ratio Mass Spectrometry (GC×GCC-IRMS)

    PubMed Central

    Tobias, Herbert J.; Zhang, Ying; Auchus, Richard J.; Brenna, J. Thomas

    2011-01-01

    We report the first demonstration of Comprehensive Two-dimensional Gas Chromatography Combustion Isotope Ratio Mass Spectrometry (GC×GCC-IRMS) for the analysis of urinary steroids to detect illicit synthetic testosterone use, of interest in sport doping. GC coupled to IRMS (GCC-IRMS) is currently used to measure the carbon isotope ratios (CIR, δ13C) of urinary steroids in anti-doping efforts; however, extensive cleanup of urine extracts is required prior to analysis to enable baseline separation of target steroids. With its greater separation capabilities, GC×GC has the potential to reduce sample preparation requirements and enable CIR analysis of minimally processed urine extracts. Challenges addressed include on-line reactors with minimized dimensions to retain narrow peaks shapes, baseline separation of peaks in some cases, and reconstruction of isotopic information from sliced steroid chromatographic peaks. Difficulties remaining include long-term robustness of on-line reactors and urine matrix effects that preclude baseline separation and isotopic analysis of low concentration and trace components. In this work, steroids were extracted, acetylated, and analyzed using a refined, home-built GC×GCC-IRMS system. 11-hydroxy-androsterone (11OHA) and 11-ketoetiocolanolone (11KE) were chosen as endogenous reference compounds (ERC) because of their satisfactory signal intensity, and their CIR was compared to target compounds (TC) androsterone (A) and etiocholanolone (E). Separately, a GC×GC-qMS system was used to measure testosterone (T)/EpiT concentration ratios. Urinary extracts of urine pooled from professional athletes, and urine from one individual that received testosterone gel (T-gel) and one individual that received testosterone injections (T-shot) were analyzed. The average precisions of δ13C and Δδ13C measurements were SD(δ13C) approximately ± 1‰ (n=11). The T-shot sample resulted in a positive for T use with a T/EpiT ratio of > 9 and CIR measurements of Δδ13C > 5‰, both fulfilling World Anti-Doping Agency criteria. These data show for the first time that synthetic steroid use is detectable by GC×GCC-IRMS without need for extensive urine cleanup. PMID:21846122

  9. Diagnostic accuracy of self-administered urine glucose test strips as a diabetes screening tool in a low-resource setting in Cambodia.

    PubMed

    Storey, Helen L; van Pelt, Maurits H; Bun, Socheath; Daily, Frances; Neogi, Tina; Thompson, Matthew; McGuire, Helen; Weigl, Bernhard H

    2018-03-22

    Screening for diabetes in low-resource countries is a growing challenge, necessitating tests that are resource and context appropriate. The aim of this study was to determine the diagnostic accuracy of a self-administered urine glucose test strip compared with alternative diabetes screening tools in a low-resource setting of Cambodia. Prospective cross-sectional study. Members of the Borey Santepheap Community in Cambodia (Phnom Penh Municipality, District Dangkao, Commune Chom Chao). All households on randomly selected streets were invited to participate, and adults at least 18 years of age living in the study area were eligible for inclusion. The accuracy of self-administered urine glucose test strip positivity, Hemoglobin A1c (HbA1c)>6.5% and capillary fasting blood glucose (cFBG) measurement ≥126 mg/dL were assessed against a composite reference standard of cFBGmeasurement ≥200 mg/dL or venous blood glucose 2 hours after oral glucose tolerance test (OGTT) ≥200 mg/dL. Of the 1289 participants, 234 (18%) had diabetes based on either cFBG measurement (74, 32%) or the OGTT (160, 68%). The urine glucose test strip was 14% sensitive and 99% specific and failed to identify 201 individuals with diabetes while falsely identifying 7 without diabetes. Those missed by the urine glucose test strip had lower venous fasting blood glucose, lower venous blood glucose 2 hours after OGTT and lower HbA1c compared with those correctly diagnosed. Low cost, easy to use diabetes tools are essential for low-resource communities with minimal infrastructure. While the urine glucose test strip may identify persons with diabetes that might otherwise go undiagnosed in these settings, its poor sensitivity cannot be ignored. The massive burden of diabetes in low-resource settings demands improvements in test technologies. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Antimicrobial susceptibility patterns of enterobacteriaceae isolated from HIV-infected patients in Kinshasa.

    PubMed

    Iyamba, Jean-Marie Liesse; Wambale, José Mulwahali; Takaisi-Kikuni, Ntondo Za Balega

    2014-01-01

    People infected by Human Immunodeficiency Virus (HIV) are susceptible to develop severe bacterial infections. We set out to determine the frequency and the sensitivity to antibiotics of enterobaceriaceae isolated from urine and feces of HIV-infected persons. Urine and feces samples were collected from HIV-infected patients of the Centre de Traitement Ambulatoire de Kabinda (CTA/Kabinda, Kinshasa) and analyzed at the Reference National Laboratory for HIV/AIDS and Sexually Transmitted Infections. The isolated enterobacteriaceae strains were identified by conventional microbiological methods. Antibiotic sensitivity pattern was carried out by disc diffusion method. THE FOLLOWING BACTERIA PATHOGENS WERE ISOLATED: Escherichia coli, Klebsiella, Enterobacter, Proteus, and Providencia. Most species were sensitive to cefotaxim, ceftriaxon, and gentamicin and resistant to chloramphenicol, cotrimoxazole, tetracycline, and norfloxacin. The results of the present study show that the most frequently bacteria isolated were Esherichia coli and cefotaxim, ceftriaxon, and gentamicin were the most active antibiotics.

  11. Environmental and biological monitoring of occupational exposure to organic micropollutants in gasoline.

    PubMed

    Senzolo, C; Frignani, S; Pavoni, B

    2001-07-01

    An exposure risk assessment of workers in a refinery production unit was undertaken. Gasoline and its main components were investigated through environmental and biological monitoring. Measured variables were environmental benzene, toluene, pentane and hexane; benzene and toluene in blood and urine; tt-MA (metabolite of benzene) in urine. Multivariate statistical analysis of the data showed that worker's exposure to the above substances fell within the limits specified by organisations such as ACGIH. Also, biological values complied with reference values (RV) for non-occupationally-exposed population. Different values of biological variables were determined by separating smokers from non-smokers: smokers had hematic and urinary benzene values significantly higher than non-smokers. During a 3-yr sampling, it was possible to identify a significant decrease of benzene in the workplace air and of hematic benzene for non-smokers. The most exposed department, one in which tank-lorries were loaded, needs further investigation and extended monitoring.

  12. 210Po Log-normal distribution in human urines: Survey from Central Italy people

    PubMed Central

    Sisti, D.; Rocchi, M. B. L.; Meli, M. A.; Desideri, D.

    2009-01-01

    The death in London of the former secret service agent Alexander Livtinenko on 23 November 2006 generally attracted the attention of the public to the rather unknown radionuclide 210Po. This paper presents the results of a monitoring programme of 210Po background levels in the urines of noncontaminated people living in Central Italy (near the Republic of S. Marino). The relationship between age, sex, years of smoking, number of cigarettes per day, and 210Po concentration was also studied. The results indicated that the urinary 210Po concentration follows a surprisingly perfect Log-normal distribution. Log 210Po concentrations were positively correlated to age (p < 0.0001), number of daily smoked cigarettes (p = 0.006), and years of smoking (p = 0.021), and associated to sex (p = 0.019). Consequently, this study provides upper reference limits for each sub-group identified by significantly predictive variables. PMID:19750019

  13. Recent Space Shuttle crew compartment design improvements

    NASA Technical Reports Server (NTRS)

    Goodman, Jerry R.

    1986-01-01

    Significant design changes to the Space Shuttle waste management system (WMS) and its related personal hygiene support provisions (PHSP) have been made recently to improve overall operational performance and human factors interfaces. The WMS design improvements involve increased urinal flow, individual urinals, and provisions for manually compacting feces and cleanup materials to ensure adequate mission capacity. The basic arrangement and stowage of the PHSP used during waste management operations were extensively changed to better serve habitability concerns and operations needs, and to improve the hygiene of WMS operations. This paper describes these changes and the design, development, and flight test evaluation. In addition, provisions for an eighth crewmember and a new four-tier sleep station are described.

  14. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  15. Paracetamol pharmacokinetics and metabolism in young women.

    PubMed

    Allegaert, Karel; Peeters, Mariska Y; Beleyn, Bjorn; Smits, Anne; Kulo, Aida; van Calsteren, Kristel; Deprest, Jan; de Hoon, Jan; Knibbe, Catherijne A J

    2015-11-13

    There is relevant between individual variability in paracetamol clearance in young women. In this pooled study, we focused on the population pharmacokinetic profile of intravenous paracetamol metabolism and its covariates in young women. Population PK parameters using non-linear mixed effect modelling were estimated in a pooled dataset of plasma and urine PK studies in 69 young women [47 at delivery, 8/47 again 10-15 weeks after delivery (early postpartum), and 7/8 again 1 year after delivery (late postpartum), 22 healthy female volunteers with or without oral contraceptives]. Population PK parameters were estimated based on 815 plasma samples and 101 urine collections. Compared to healthy female volunteers (reference group) not on oral contraceptives, being at delivery was the most significant covariate for clearance to paracetamol glucuronide (Factor = 2.03), while women in early postpartum had decreased paracetamol glucuronidation clearance (Factor = 0.55). Women on contraceptives showed increased paracetamol glucuronidation clearance (Factor = 1.46). The oestradiol level did not further affect this model. Being at delivery did not prove significant for clearance to paracetamol sulphate, but was higher in pregnant women who delivered preterm (<37 weeks, Factor = 1.34) compared to term delivery and non-pregnant women. Finally, clearance of unchanged paracetamol was dependent on urine flow rate. Compared to healthy female volunteers not on oral contraceptives, urine paracetamol glucuronidation elimination in young women is affected by pregnancy (higher), early postpartum (lower) or exposure to oral contraceptives (higher), resulting in at least a two fold variability in paracetamol clearance in young women.

  16. Comprehensive Metaproteomic Analyses of Urine in the Presence and Absence of Neutrophil-Associated Inflammation in the Urinary Tract

    PubMed Central

    Yu, Yanbao; Sikorski, Patricia; Smith, Madeline; Bowman-Gholston, Cynthia; Cacciabeve, Nicolas; Nelson, Karen E.; Pieper, Rembert

    2017-01-01

    Inflammation in the urinary tract results in a urinary proteome characterized by a high dynamic range of protein concentrations and high variability in protein content. This proteome encompasses plasma proteins not resorbed by renal tubular uptake, renal secretion products, proteins of immune cells and erythrocytes derived from trans-urothelial migration and vascular leakage, respectively, and exfoliating urothelial and squamous epithelial cells. We examined how such proteins partition into soluble urine (SU) and urinary pellet (UP) fractions by analyzing 33 urine specimens 12 of which were associated with a urinary tract infection (UTI). Using mass spectrometry-based metaproteomic approaches, we identified 5,327 non-redundant human proteins, 2,638 and 4,379 of which were associated with SU and UP fractions, respectively, and 1,206 non-redundant protein orthology groups derived from pathogenic and commensal organisms of the urogenital tract. Differences between the SU and UP proteomes were influenced by local inflammation, supported by respective comparisons with 12 healthy control urine proteomes. Clustering analyses showed that SU and UP fractions had proteomic signatures discerning UTIs, vascular injury, and epithelial cell exfoliation from the control group to varying degrees. Cases of UTI revealed clusters of proteins produced by activated neutrophils. Network analysis supported the central role of neutrophil effector proteins in the defense against invading pathogens associated with subsequent coagulation and wound repair processes. Our study expands the existing knowledge of the urinary proteome under perturbed conditions, and should be useful as reference dataset in the search of biomarkers. PMID:28042331

  17. Metabolism of the new designer drug alpha-pyrrolidinopropiophenone (PPP) and the toxicological detection of PPP and 4'-methyl-alpha-pyrrolidinopropiophenone (MPPP) studied in rat urine using gas chromatography-mass spectrometry.

    PubMed

    Springer, Dietmar; Fritschi, Giselher; Maurer, Hans H

    2003-11-05

    R,S-alpha-pyrrolidinopropiophenone (PPP) is a new designer drug with assumed amphetamine-like effects which has appeared on the illicit drug market. The aim of this study was to identify the PPP metabolites using solid-phase extraction, ethylation or acetylation as well as to develop a toxicological detection procedure in urine using solid-phase extraction, trimethylsilylation and gas chromatography-mass spectrometry (GC-MS). Analysis of urine samples of rats treated with PPP revealed that PPP was extensively metabolized by hydroxylation of the pyrrolidine ring with subsequent dehydrogenation to the corresponding lactam, hydroxylation of the aromatic ring in position 4' or double dealkylation of the pyrrolidine ring to the corresponding primary amine (cathinone) partly followed by reduction of the keto group to the corresponding secondary alcohol (norephedrines). As cathinone and the norephedrine diastereomers are also formed after intake of other drugs of abuse or medicaments, special attention must be paid to the detection of the unequivocal metabolite 2"-oxo-PPP as an unambiguous proof for the intake of PPP. The hydroxy groups were found to be partly conjugated. Based on these data, PPP could be detected in urine via its metabolites by full-scan GC-MS using mass chromatography for screening and library search for identification by comparison of the spectra with reference spectra. The same toxicological detection procedure can be applied to other designer drugs of the pyrrolidinophenone type, like MOPPP, MDPPP, MPHP, and MPPP. The detection of the latter will also be presented here.

  18. A Retrospective Analysis of Urine Drugs of Abuse Immunoassay True Positive Rates at a National Reference Laboratory.

    PubMed

    Johnson-Davis, Kamisha L; Sadler, Aaron J; Genzen, Jonathan R

    2016-03-01

    Urine drug screens are commonly performed to identify drug use or monitor adherence to drug therapy. The purpose of this retrospective study was to evaluate the true positive and false positive rates of one of our in-house urine drug screen panels. The urine drugs of abuse panel studied consists of screening by immunoassay then positive immunoassay results were confirmed by mass spectrometry. Reagents from Syva and Microgenics were used for the immunoassay screen. The screen was performed on a Beckman AU5810 random access automated clinical analyzer. The percent of true positives for each immunoassay was determined. Agreement with previously validated GC-MS or LC-MS-MS confirmatory methods was also evaluated. There were 8,825 de-identified screening results for each of the drugs in the panel, except for alcohol (N = 2,296). The percent of samples that screened positive were: 10.0% for amphetamine/methamphetamine/3,4-methylenedioxy-methamphetamine (MDMA), 12.8% for benzodiazepines, 43.7% for opiates (including oxycodone) and 20.3% for tetrahydrocannabinol (THC). The false positive rate for amphetamine/methamphetamine was ∼14%, ∼34% for opiates (excluding oxycodone), 25% for propoxyphene and 100% for phencyclidine and MDMA immunoassays. Based on the results from this retrospective study, the true positive rate for THC drug use among adults were similar to the rate of illicit drug use in young adults from the 2013 National Survey; however, our positivity rate for cocaine was higher than the National Survey. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Performance evaluation of the new fully automated urine particle analyser UF-5000 compared to the reference method of the Fuchs-Rosenthal chamber.

    PubMed

    Previtali, Giulia; Ravasio, Rudi; Seghezzi, Michela; Buoro, Sabrina; Alessio, Maria Grazia

    2017-09-01

    UF-5000 is the new fully automated urine particle analyser. We validated its performance. 736 urines were analysed and results were compared by two pathologists on uncentrifuged samples, using Fuchs-Rosenthal chamber. AUC of ROC curve ranged between 0.86 and 0.99. Sensitivity was >0.90 for all the elements and similar for RBC and yeasts. Specificity ranged between 0.74 and 0.89 for total cast, epithelial/non-squamous/renal-tubular cells and RBC. For all the other parameters specificity was >0.90. Comparison with Fuchs-Rosenthal chamber was very good for all the parameters; r ranged between 0.52 and 0.99 except for pathological cast because of the lack of the pathological samples in medium and higher ranges. Linearity performance (R 2 ) was 1.00, 1.00 and 0.99 respectively for RBC, WBC and epithelial cells (EC). No carry-over was observed. The within-run imprecision was 25.42%,13.81%,1.36% for RBC; 37.50%,10.16%,1.41% for WBC and 35.25%, 17.85%,6.30% for EC at low, near the cut off level and high concentrations, respectively. The between-run imprecision was 6.90%,1.60% for RBC, 4.10%,1.90% for WBC and 7.60%,7.30% for EC, using low and high positive quality controls, respectively. UF-5000 is an analyser of great interest to detect urine particle related to pathological process of kidney and urinary tract. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Method validation and determinations of levofloxacin, metronidazole and sulfamethoxazole in an aqueous pharmaceutical, urine and blood plasma samples using quantitative nuclear magnetic resonance spectrometry.

    PubMed

    Salem, Alaa A; Mossa, Hussein A

    2012-01-15

    Selective, rapid and accurate quantitative proton nuclear magnetic resonance (qHNMR) method for the determination of levofloxacin, metronidazole benzoate and sulfamethoxazole in aqueous solutions was developed and validated. The method was successfully applied to the determinations of the drugs and their admixtures in pharmaceutical, urine and plasma samples. Maleic acid and sodium malate were used as internal standards. Effect of temperature on spectral measurements was evaluated. Linear dynamic ranges of 0.50-68.00, 0.13-11.30 and 0.24-21.00 mg per 0.60 mL solution were obtained for levofloxacin, metronidazole benzoate and sulfamethoxazole, respectively. Average recovery % in the range of 96.00-104.20 ± (0.17-2.91) was obtained for drugs in pure, pharmaceutical, plasma and urine samples. Inter and intra-day analyses gave average recoveries % in the ranges 96.10-98.40 ± (1.68-2.81) and 96.00-104.20 ± (0.17-2.91), respectively. Instrumental detection limits ≤0.03 mg per 0.6 mL were obtained for the three drugs. Developed method has demonstrated high performance characteristics for analyzing investigated drugs and their admixtures. Student t-test at 95% confidence level revealed insignificant bias between the real and measured contents of investigated drugs in pure, pharmaceutical, urine and plasma samples and its admixtures. Application of the statistical F-test revealed insignificant differences in precisions between the developed method and arbitrary selected reference methods. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Urinary shedding of pathogenic Leptospira in stray dogs and cats, Algiers: A prospective study.

    PubMed

    Zaidi, Sara; Bouam, Amar; Bessas, Amina; Hezil, Djamila; Ghaoui, Hicham; Ait-Oudhia, Khatima; Drancourt, Michel; Bitam, Idir

    2018-01-01

    Leptospirosis is an important worldwide zoonosis. This disease is caused by pathogenic species of the genus Leptospira which are maintained in the environment via chronic renal infection of carrier animals which can be asymptomatic excretors of the organisms in their urines and become a source of infection for humans and other hosts. The prevalence of animal leptospirosis in Algiers, Algeria, is unknown. Real-time PCR and standard PCR and sequencing were used to detect pathogenic Leptospira organisms in the urines of stray dogs and cats in Algiers. In the presence of appropriate controls, none of the 107 cat urine samples were positive while 5/104 (4.8%) canine urine samples (asymptomatic mixed-breed dogs, three females and two males) were positive in two real-time PCR assays targeting the rrs and hsp genes. The positivity of these samples was confirmed by partial PCR-sequencing of the rpoB gene which yielded 100% sequence similarity with Leptospira interrogans reference sequence. In this study, L. interrogans prevalence was significantly higher in dogs aged < one year (16.46% - 29.41%) than in adults (0%) (P value = 0.0001) and then in the overall dog population (2.68% - 4.8%) (P = 0.0007). These results suggest that dogs are maintenance hosts for zoonotic leptospirosis in Algiers, Algeria. To face this situation, effective canine vaccination strategies and raising public health awareness are mandatory. Further investigations incorporating a larger sample in more localities will be undertaken to document the epidemiology of urban animal leptospirosis in Algeria at large.

  2. [Occupational acute mercury intoxication--a case report].

    PubMed

    Złotkowska, Renata; Zajac-Nedza, Maria

    2002-01-01

    The aim of this paper is to present a case of acute occupational mercury poisoning treated at the Clinical Department of Occupational Diseases. A welder, forty years old was employed at a large chemical plant in the dissembling department involved in the production of acetaldehyde. The patient was referred to the hospital by an occupational physician. During his shift; dissembling mercury-covered tubes a nausea, abdominal pain and elevated temperature occurred. He was also complaining of headache and symptoms of gingivitis, which lasted two weeks before hospitalization. Before admission to the Clinical Department, mercury concentrations in urine were measured twice. The urine mercury levels were very high, impossible to determine precisely. During hospitalization, the patient was complaining of head and gingiva pains. Since the symptoms persisted and high urine mercury levels (830 micrograms/l) were determined--DMPS--Heyl was administered. After treatment symptoms subsided and the concentration of mercury in urine was gradually returning to normal. The results of laboratory tests did not reveal any impairment of internal organs. Consultant in neurology found the presence of nystagmus and positive Romberg test in the patient. Neurological signs disappeared after a month. The measurements performed by the Department of Work Safety revealed high exceeded hygiene permissible limits of mercury vapors in the air. The information provided by the employer's technical services also showed that the patient was working with the face mask, but its absorber was not readjusted to mercury vapors. A control ambulatory examination (one and a half year later) did not reveal health effects of acute exposure to mercury vapors.

  3. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers, 400... Materials Document number and name Part 1068reference SAE J1930, Electrical/Electronic Systems Diagnostic...

  4. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers, 400... Materials Document number and name Part 1068reference SAE J1930, Electrical/Electronic Systems Diagnostic...

  5. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Reference materials. 1042.910 Section... Other Reference Information § 1042.910 Reference materials. Documents listed in this section have been... information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  6. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Reference materials. 1042.910 Section... Other Reference Information § 1042.910 Reference materials. Documents listed in this section have been... information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  7. 40 CFR 1043.100 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Reference materials. 1043.100 Section... § 1043.100 Reference materials. Documents listed in this section have been incorporated by reference into... the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  8. Ammonia Inactivation of Ascaris Ova in Ecological Compost by Using Urine and Ash

    PubMed Central

    Parzen, Rebecca E.; Mercado Guzmán, Álvaro

    2012-01-01

    Viable ova of Ascaris lumbricoides, an indicator organism for pathogens, are frequently found in feces-derived compost produced from ecological toilets, demonstrating that threshold levels of time, temperature, pH, and moisture content for pathogen inactivation are not routinely met. Previous studies have determined that NH3 has ovicidal properties for pathogens, including Ascaris ova. This research attempted to achieve Ascaris inactivation via NH3 under environmental conditions commonly found in ecological toilets and using materials universally available in an ecological sanitation setting, including compost (feces and sawdust), urine, and ash. Compost mixed with stored urine and ash produced the most rapid inactivation, with significant inactivation observed after 2 weeks and with a time to 99% ovum inactivation (T99) of 8 weeks. Compost mixed with fresh urine and ash achieved a T99 of 15 weeks, after a 4-week lag phase. Both matrices had relatively high total-ammonia concentrations and pH values of >9.24 (pKa of ammonia). In compost mixed with ash only, and in compost mixed with fresh urine only, inactivation was observed after an 11-week lag phase. These matrices contained NH3 concentrations of 164 to 173 and 102 to 277 mg/liter, respectively, when inactivation occurred, which was below the previously hypothesized threshold for inactivation (280 mg/liter), suggesting that a lower threshold NH3 concentration may be possible with a longer contact time. Other significant results include the hydrolysis of urea to ammonia between pH values of 10.4 and 11.6, above the literature threshold pH of 10. PMID:22582051

  9. Ammonia inactivation of Ascaris ova in ecological compost by using urine and ash.

    PubMed

    McKinley, James W; Parzen, Rebecca E; Mercado Guzmán, Álvaro

    2012-08-01

    Viable ova of Ascaris lumbricoides, an indicator organism for pathogens, are frequently found in feces-derived compost produced from ecological toilets, demonstrating that threshold levels of time, temperature, pH, and moisture content for pathogen inactivation are not routinely met. Previous studies have determined that NH(3) has ovicidal properties for pathogens, including Ascaris ova. This research attempted to achieve Ascaris inactivation via NH(3) under environmental conditions commonly found in ecological toilets and using materials universally available in an ecological sanitation setting, including compost (feces and sawdust), urine, and ash. Compost mixed with stored urine and ash produced the most rapid inactivation, with significant inactivation observed after 2 weeks and with a time to 99% ovum inactivation (T(99)) of 8 weeks. Compost mixed with fresh urine and ash achieved a T(99) of 15 weeks, after a 4-week lag phase. Both matrices had relatively high total-ammonia concentrations and pH values of >9.24 (pK(a) of ammonia). In compost mixed with ash only, and in compost mixed with fresh urine only, inactivation was observed after an 11-week lag phase. These matrices contained NH(3) concentrations of 164 to 173 and 102 to 277 mg/liter, respectively, when inactivation occurred, which was below the previously hypothesized threshold for inactivation (280 mg/liter), suggesting that a lower threshold NH(3) concentration may be possible with a longer contact time. Other significant results include the hydrolysis of urea to ammonia between pH values of 10.4 and 11.6, above the literature threshold pH of 10.

  10. Pre-operative Asymptomatic Bacteriuria: A Risk Factor For Prosthetic Joint Infection?

    PubMed

    Weale, R; El-Bakri, F; Saeed, Kordo

    2018-04-13

    Infection is a rare complication following implantation of prosthetic material into a joint. The impact of asymptomatic bacteriuria (ASB) before elective operations and the subsequent risk of prosthetic joint infection (PJI) are not well understood. • Assess the prevalence of ASB amongst patients undergoing total arthroplasty of the hip and knee. • Determine the rates of PJI diagnosed within two years of the arthroplasty and if ASB is an independent risk factor for developing PJI. Patients who had total/unicondylar knee or total hip arthroplasty were retrospectively reviewed over a five-year period. Pre-operative urine samples within one year of surgery were analysed and those with ASB identified. Primary outcome was prosthetic joint infection (PJI) within the first postoperative year. 5542 patients were included. 4368 had a pre-operative urine culture recorded. The prevalence of ASB was 140 of 4368 (3.2%). The overall PJI rate was 56 of 5542 (1.01%). Of those with a PJI, 33 had a pre-operative urine sample recorded. The infection rate in the ASB group was 5% (7 of 140), in the no-ASB group it was 0.61% (26 of 4228) and in the group without a urine sample it was 1.96% (23 of 1174) (p value <0.001). The ASB isolate was the same microorganism as the PJI isolate in only one of the seven cases. The association between ASB and PJI is statistically significant, but the urine isolates did not relate to the isolates in the prosthetic joint, suggestive the relationship is unlikely causal. Copyright © 2018. Published by Elsevier Ltd.

  11. Urine chemistry

    MedlinePlus

    ... rate 24-hour urine protein Acid loading test (pH) Adrenalin - urine test Amylase - urine Bilirubin - urine Calcium - urine Citric acid ... Urine dermatan sulfate Urine - hemoglobin Urine metanephrine Urine pH Urine specific gravity Vanillylmandelic acid (VMA)

  12. [Pyroglutamic acidemia associated with acetaminophen].

    PubMed

    Alados Arboledas, F J; de la Oliva Senovilla, P; García Muñoz, Ma J; Alonso Melgar, A; Ruza Tarrío, F

    2007-12-01

    We report a case of pyroglutamic acidemia probably related to acetaminophen administration. A 16-month boy recovering from hemolytic uremic syndrome abruptly developed unexplained high anion gap metabolic acidosis requiring hemodialysis. Septic shock, lactic acidosis and salicylate intoxication were ruled out. Betahydroxybutyrate and acetoacetate levels were within the normal range. No osmolarity gap or high amino acid levels were found. Urine and blood pyroglutamic acid levels were 392 mmol/mol creatinine (reference range: 9-55) and 9.8 mmol/L (reference range<0.16), respectively. The patient was receiving acetaminophen. We conclude that pyroglutamic acidosis should be considered in patients receiving acetaminophen who abruptly develop high anion gap metabolic acidosis not attributable to more common causes.

  13. Essential and toxic element concentrations in blood and urine and their associations with diet: results from a Norwegian population study including high-consumers of seafood and game.

    PubMed

    Birgisdottir, B E; Knutsen, H K; Haugen, M; Gjelstad, I M; Jenssen, M T S; Ellingsen, D G; Thomassen, Y; Alexander, J; Meltzer, H M; Brantsæter, A L

    2013-10-01

    The first aim of the study was to evaluate calculated dietary intake and concentrations measured in blood or urine of essential and toxic elements in relation to nutritional and toxicological reference values. The second aim was to identify patterns of the element concentrations in blood and urine and to identify possible dietary determinants of the concentrations of these elements. Adults with a known high consumption of environmental contaminants (n=111), and a random sample of controls (n=76) answered a validated food frequency questionnaire (FFQ). Complete data on biological measures were available for 179 individuals. Blood and urine samples were analyzed for selenium, iodine, arsenic, mercury, cadmium and lead. Principal component analysis was used to identify underlying patterns of correlated blood and urine concentrations. The calculated intakes of selenium, iodine, inorganic arsenic and mercury were within guideline levels. For cadmium 24% of the high consumer group and 8% of the control group had intakes above the tolerable weekly intake. Concentrations of lead in blood exceeded the bench-mark dose lower confidence limits for some participants. However, overall, the examined exposures did not give rise to nutritional or toxicological concerns. Game consumption was associated with lead in blood (B(ln) 0.021; 95%CI:0.010, 0.031) and wine consumption. Seafood consumption was associated with urinary cadmium in non-smokers (B(ln) 0.009; 95%CI:0.003, 0.015). A novel finding was a distinct pattern of positively associated biological markers, comprising iodine, selenium, arsenic and mercury (eigenvalue 3.8), reflecting seafood intake (B 0.007; 95%CI:0.004, 0.010). The study clearly demonstrates the significance of seafood as a source of both essential nutrients and toxic elements simultaneously and shows that exposure to various essential and toxic elements can be intertwined. © 2013 Elsevier B.V. All rights reserved.

  14. Immunoextraction-Tandem Mass Spectrometry Method for Measuring Intact Human Chorionic Gonadotropin, Free β-Subunit, and β-Subunit Core Fragment in Urine

    PubMed Central

    Woldemariam, Getachew A.; Butch, Anthony W.

    2015-01-01

    BACKGROUND Human chorionic gonadotropin (hCG) stimulates testosterone production by the testicles. Because of the potential for abuse, hCG is banned (males only) in most sports and has been placed on the World Anti-Doping Agency list of prohibited substances. Intact hCG, free β-subunit (hCGβ), and β-subunit core fragment (hCGβcf) are the major variants or isoforms in urine. Immunoassays are used by antidoping laboratories to measure urinary hCG. Cross-reactivity with isoforms differs among immunoassays, resulting in widely varying results. We developed a sequential im-munoextraction method with LC-MS/MS detection for quantification of intact hCG, hCGβ, and hCGβcf in urine. METHODS hCG isoforms were immunoextracted with antibody-conjugated magnetic beads and digested with trypsin, and hCGβ and hCGβcf unique peptides were quantified by LC-MS/MS with the corresponding heavy peptides as internal standard. hCG isoform concentrations were determined in urine after administration of hCG, and the intact hCG results were compared to immunoassay results. RESULTS The method was linear to 20 IU/L. Total imprecision was 6.6%-13.7% (CV), recovery ranged from 91% to 109%, and the limit of quantification was 0.2 IU/L. Intact hCG predominated in the urine after administration of 2 hCG formulations. The window of detection ranged from 6 to 9 days. Mean immunoassay results were 12.4-15.5 IU/L higher than LC-MS/MS results. CONCLUSIONS The performance characteristics of the method are acceptable for measuring hCG isoforms, and the method can quantify intact hCG and hCGβ separately. The limit of quantification will allow LC-MS/MS hCG reference intervals to be established in nondoping male athletes for improved doping control. PMID:24899693

  15. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  16. IRMS detection of testosterone manipulated with 13C labeled standards in human urine by removing the labeled 13C.

    PubMed

    Wang, Jingzhu; Yang, Rui; Yang, Wenning; Liu, Xin; Xing, Yanyi; Xu, Youxuan

    2014-12-10

    Isotope ratio mass spectrometry (IRMS) is applied to confirm testosterone (T) abuse by determining the carbon isotope ratios (δ(13)C value). However, (13)C labeled standards can be used to control the δ(13)C value and produce manipulated T which cannot be detected by the current method. A method was explored to remove the (13)C labeled atom at C-3 from the molecule of androsterone (Andro), the metabolite of T in urine, to produce the resultant (A-nor-5α-androstane-2,17-dione, ANAD). The difference in δ(13)C values between Andro and ANAD (Δδ(13)CAndro-ANAD, ‰) would change significantly in case manipulated T is abused. Twenty-one volunteers administered T manipulated with different (13)C labeled standards. The collected urine samples were analyzed with the established method, and the maximum value of Δδ(13)CAndro-ANAD post ingestion ranged from 3.0‰ to 8.8‰. Based on the population reference, the cut-off value of Δδ(13)CAndro-ANAD for positive result was suggested as 1.2‰. The developed method could be used to detect T manipulated with 3-(13)C labeled standards. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Phylogenetic reconstruction and polymorphism analysis of BK virus VP2 gene isolated from renal transplant recipients in China

    PubMed Central

    WANG, ZHANG-YANG; HONG, WEI-LONG; ZHU, ZHE-HUI; CHEN, YUN-HAO; YE, WEN-LE; CHU, GUANG-YU; LI, JIA-LIN; CHEN, BI-CHENG; XIA, PENG

    2015-01-01

    BK polyomavirus (BKV) is important pathogen for kidney transplant recipients, as it is frequently re-activated, leading to nephropathy. The aim of this study was to investigate the phylogenetic reconstruction and polymorphism of the VP2 gene in BKV isolated from Chinese kidney transplant recipients. Phylogenetic analysis was carried out in the VP2 region from 135 BKV-positive samples and 28 reference strains retrieved from GenBank. The unweighted pair-group method with arithmetic mean (UPGMA) grouped all strains into subtypes, but failed to subdivide strains into subgroups. Among the plasma and urine samples, all plasma (23/23) and 82 urine samples (82/95) were identified to contain subtype I; the other 10 urine samples contained subtype IV. A 86-bp fragment was identified as a highly conserved sequence. Following alignment with 36 published BKV sequences from China, 92 sites of polymorphism were identified, including 11 single nucleotide polymorphisms (SNPs) prevalent in Chinese individuals and 30 SNPs that were specific to the two predominant subtypes I and IV. The limitations of the VP2 gene segment in subgrouping were confirmed by phylogenetic analysis. The conserved sequence and polymorphism identified in this study may be helpful in the detection and genotyping of BKV. PMID:26640547

  18. Suspected carprofen toxicosis caused by coprophagia in a dog.

    PubMed

    Hutchins, Rae G; Messenger, Kristen M; Vaden, Shelly L

    2013-09-01

    A 1-year-old spayed female mixed-breed dog was evaluated because of urinary incontinence, polyuria, polydipsia, and minimally concentrated urine. Markedly high circulating alanine transaminase activity, mildly high circulating alkaline phosphatase activity, and low urine specific gravity were detected for the dog. Results of ultrasonographic examination of the abdomen and cytologic examination of liver samples were unremarkable. Carprofen was detected in serum and plasma samples obtained from the dog. Exposure to carprofen was attributed to ingestion of feces of another dog in the household that was receiving the drug daily. Access to feces of other dogs in the household was prevented; no other treatment was initiated. Urinary incontinence, polyuria, and polydipsia resolved, and urine specific gravity increased within 7 days following discontinuation of consumption of feces. Alanine transaminase activity was substantially lower than the value determined during the initial examination, and alkaline phosphatase activity was within the reference range 5 weeks after discontinuation of consumption of feces by the dog. Findings for the dog of this report suggested that carprofen toxicosis can be caused by consumption of feces of another dog receiving the drug. This cause of adverse effects should be a differential diagnosis for dogs with clinical signs and clinicopathologic abnormalities consistent with carprofen toxicosis.

  19. Attempt to run urinary protein electrophoresis using capillary technique.

    PubMed

    Falcone, Michele

    2014-10-01

    The study of urinary protein has a predominant place in the diagnosis of kidney disease. The most common technique is agarose gel electrophoresis (AGE). For several years, the technique of choice applied to the analysis of serum proteins has been CE, a system that uses capillary fused silica, subjected to high voltage to separate and measure serum proteins. The purpose of this paper was to perform capillary electrophoresis on urinary proteins which, at present, are not interpretable due to the many nonspecific peaks visible when using gel electrophoresis. In order to carry out our research, we used a capillary V8 analyzer together with an agarose gel system from the same company. AGE was taken as the reference method, for which urine was used without any pretreatment. For the V8 system, urine was subjected to purification on granular-activated carbon and then inserted into the V8 analyzer, selecting a program suitable for liquids with low protein content. We examined 19 urine samples collected over 24 hrs from both hospitalized and external patients with different types of proteinuria plus a serum diluted 1/61 considered as a control to recognize the bands. Both methods showed the same protein fractions and classified the proteinuria in a similar way. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Mutagenicity studies in a tyre plant: in vitro activity of workers' urinary concentrates and raw materials.

    PubMed

    Crebelli, R; Paoletti, A; Falcone, E; Aquilina, G; Fabri, G; Carere, A

    1985-07-01

    The possible contribution to urinary mutagenicity of occupational exposures in the rubber industry was studied by assaying the urine concentrates of 72 workmen (44 smokers) employed in a tyre plant. Twenty three clerks (16 smokers) engaged in the administrative department of the same factory served as presumptive unexposed controls. XAD-2 resin concentrates of urine samples were assayed in the plate incorporation test and in the microtitre fluctuation assay with Salmonella typhimurium strains TA1535, TA98, and TA100. Furthermore, the in vitro mutagenicity of the major raw materials in use at the plant was determined in the plate incorporation assay with S typhimurium strains TA1535, TA1537, TA98, and TA100. The results obtained from the urinary mutagenicity study show that smoking habits, but not occupation, were statistically significantly related to the appearance of a urinary mutagenicity that was detectable with strain TA98. A possible synergistic effect of occupation with smoking was observed among tyre builders who were also smokers. The study of the raw materials showed that three technical grade materials were weakly active as mutagens in strain TA98 in the absence (poly-p-dinitrosobenzene) or in the presence of metabolic activation (mixed diaryl-p-phenylendiamines and tetramethyltiuram disulphide). The latter chemical was also weakly active in strain TA100.

  1. Mutagenicity studies in a tyre plant: in vitro activity of workers' urinary concentrates and raw materials.

    PubMed Central

    Crebelli, R; Paoletti, A; Falcone, E; Aquilina, G; Fabri, G; Carere, A

    1985-01-01

    The possible contribution to urinary mutagenicity of occupational exposures in the rubber industry was studied by assaying the urine concentrates of 72 workmen (44 smokers) employed in a tyre plant. Twenty three clerks (16 smokers) engaged in the administrative department of the same factory served as presumptive unexposed controls. XAD-2 resin concentrates of urine samples were assayed in the plate incorporation test and in the microtitre fluctuation assay with Salmonella typhimurium strains TA1535, TA98, and TA100. Furthermore, the in vitro mutagenicity of the major raw materials in use at the plant was determined in the plate incorporation assay with S typhimurium strains TA1535, TA1537, TA98, and TA100. The results obtained from the urinary mutagenicity study show that smoking habits, but not occupation, were statistically significantly related to the appearance of a urinary mutagenicity that was detectable with strain TA98. A possible synergistic effect of occupation with smoking was observed among tyre builders who were also smokers. The study of the raw materials showed that three technical grade materials were weakly active as mutagens in strain TA98 in the absence (poly-p-dinitrosobenzene) or in the presence of metabolic activation (mixed diaryl-p-phenylendiamines and tetramethyltiuram disulphide). The latter chemical was also weakly active in strain TA100. PMID:4015996

  2. Reference Materials and Subject Matter Knowledge Codes for Airman Knowledge Testing

    DOT National Transportation Integrated Search

    2004-06-08

    The listings of reference materials and subject matter knowledge codes have been : prepared by the Federal Aviation Administration (FAA) to establish specific : references for all knowledge standards. The listings contain reference materials : to be ...

  3. Health Instruction Packages: Consumer--Diabetes.

    ERIC Educational Resources Information Center

    Cross, Barbara J.; And Others

    Text, illustrations, and exercises are utilized in this set of seven learning modules designed to instruct diabetes patients in health care practices necessary for the control of their illness. The first module, by Barbara J. Cross, describes materials and procedures used in testing the urine for sugar and acetone. The second module, by Ruth…

  4. Renal Regulation of Acid-Base Balance: Ammonia Excretion.

    ERIC Educational Resources Information Center

    Tanner, George A.

    1984-01-01

    Describes an experiment which demonstrates changes in ammonia excretion and urine pH that occur in response to metabolic acidosis (induced by ammonium chloride ingestion) or metabolic alkalosis (produced by sodium bicarbonate ingestion). List of materials needed and background information are included. Typical results are provided and discussed.…

  5. 10 CFR 430.27 - Petitions for waiver and applications for interim waiver.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... design characteristics which either prevent testing of the basic model according to the prescribed test... faucets, showerheads, water closets, and urinals) as to provide materially inaccurate comparative data. (2... particular basic model(s) for which a waiver is requested, the design characteristic(s) constituting the...

  6. 10 CFR 430.27 - Petitions for waiver and applications for interim waiver.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... design characteristics which either prevent testing of the basic model according to the prescribed test... faucets, showerheads, water closets, and urinals) as to provide materially inaccurate comparative data. (2... contains a design characteristic which either prevents testing of the basic model according to the...

  7. 10 CFR 430.27 - Petitions for waiver and applications for interim waiver.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... design characteristics which either prevent testing of the basic model according to the prescribed test... faucets, showerheads, water closets, and urinals) as to provide materially inaccurate comparative data. (2... contains a design characteristic which either prevents testing of the basic model according to the...

  8. 10 CFR 430.27 - Petitions for waiver and applications for interim waiver.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... design characteristics which either prevent testing of the basic model according to the prescribed test... faucets, showerheads, water closets, and urinals) as to provide materially inaccurate comparative data. (2... particular basic model(s) for which a waiver is requested, the design characteristic(s) constituting the...

  9. 10 CFR 430.27 - Petitions for waiver and applications for interim waiver.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... design characteristics which either prevent testing of the basic model according to the prescribed test... faucets, showerheads, water closets, and urinals) as to provide materially inaccurate comparative data. (2... contains a design characteristic which either prevents testing of the basic model according to the...

  10. Easy-Access Services in Low-Threshold Opiate Agonist Maintenance

    ERIC Educational Resources Information Center

    Hesse, Morten; Pedersen, Mads U.

    2008-01-01

    Background: There is currently evidence that methadone and buprenorphine maintenance is effective in reducing substance abuse. However, it is not known whether psychosocial support improves the outcome of methadone maintenance in the absence of control measures, such as regular urine testing. Materials and Methods: In a prospective observational…

  11. 16 CFR 305.19 - Promotional material displayed or distributed at point of sale.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., general service lamps, showerheads, faucets, water closets or urinals) shall clearly and conspicuously... distribution at point-of-sale concerning a covered product that is a showerhead, faucet, water closet, or... UNDER SPECIFIC ACTS OF CONGRESS ENERGY AND WATER USE LABELING FOR CONSUMER PRODUCTS UNDER THE ENERGY...

  12. Showing Its Colors. Thin-Layer Chromatographic Detection of Cannabinoid Metabolites.

    ERIC Educational Resources Information Center

    Bonicamp, Judith M.

    1986-01-01

    Describes a chemistry laboratory experiment in which thin-layer chromatography (TLC) is used to analyze urine specimens containing metabolites of the drug tetrahydro-cannabinol, which comes from the marijuana plant. The materials needed to conduct the experiment are listed, and the procedure and expected results are outlined. (TW)

  13. Applied and environmental chemistry of animal manure: A review

    USDA-ARS?s Scientific Manuscript database

    Animal manure consists of predominantly urine and feces, but also may contain bedding materials, dropped feed, scurf and other farming wastes. The estimated amount of manure produced in 12 major livestock producing countries is 9 x109 Mg of manure annually. Manures are rich in plant nutrients. Howev...

  14. Telomerase activity in solid transitional cell carcinoma, bladder washings, and voided urine.

    PubMed

    Lance, R S; Aldous, W K; Blaser, J; Thrasher, J B

    1998-03-04

    Telomerase activity has been detected in a wide variety of human malignancies. It appears to be one of the fundamental ingredients necessary for cellular immortality. We sought to determine the incidence of telomerase activity in solid transitional cell carcinoma (TCC) specimens, benign urothelium, bladder washings, and voided urine from patients with TCC identified cystoscopically compared with controls. Telomerase activity was measured in 26 solid bladder cancers and 13 benign urothelial specimens using the telomere repeat amplification protocol (TRAP), a polymerase chain reaction (PCR) based assay. Telomerase activity was further measured in the centrifuged cellular material obtained from the bladder washings of 26 patients with TCC and 40 with benign urologic disease found to have a normal cystoscopy. All patients with hematuria were additionally evaluated with an upper tract radiographic examination and found to be free of malignancy. Voided urine was likewise evaluated in 11 patients with TCC, 12 with benign urologic diseases, and 56 asymptomatic control subjects. Telomerase activity was detected in 25 of 26 (96%) solid specimens, 21 of 26 (81%) bladder washings, and 6 of 11 (54%) voided urine specimens from patients with histologically confirmed TCC. In the control group, 2 of 13 (15%) benign urothelial specimens and 2 of 56 (4%) voided urine specimens from the asymptomatic volunteer group demonstrated telomerase activity. Of those with benign urologic disease, 16 of 40 (40%) bladder barbotage specimens and 6 of 12 (50%) voided urine specimens demonstrated telomerase activity. Sensitivity and specificity of telomerase as a marker for TCC were 81% and 60%, respectively, in the bladder washings group and 54% and 50%, respectively, in voided urine. These data indicate that activation of telomerase is frequent in solid TCC and appears to be a sensitive marker in bladder washings of patients with TCC. We noted an unexpectedly high false positive detection rate in patients with benign urologic diseases, especially those with symptomatic benign prostatic hyperplasia. An additional study of a larger number of both bladder cancer patients and those at risk is necessary to determine if telomerase activity could play a role as a diagnostic and/or surveillance marker of TCC. Published by Elsevier Science Inc.

  15. High-throughput determination of faropenem in human plasma and urine by on-line solid-phase extraction coupled to high-performance liquid chromatography with UV detection and its application to the pharmacokinetic study.

    PubMed

    Xie, Rui; Wen, Jun; Wei, Hua; Fan, Guorong; Zhang, Dabing

    2010-05-01

    An automated system using on-line solid-phase extraction and HPLC with UV detection was developed for the determination of faropenem in human plasma and urine. Analytical process was performed isocratically with two reversed-phase columns connected by a switching valve. After simple pretreatment for plasma and urine with acetonitrile, a volume of 100microl upper layer of the plasma or urine samples was injected for on-line SPE column switching HPLC-UV analysis. The analytes were retained on the self-made trap column (Lichrospher C(18), 4.6mmx37mm, 25microm) with the loading solvent (20mM NaH(2)PO(4) adjusted pH 3.5) at flow rate of 2mlmin(-1), and most matrix materials were removed from the column to waste. After 0.5min washing, the valve was switched to another position so that the target analytes could be eluted from trap column to analytical column in the back-flush mode by the mobile phase (acetonitrile-20mM NaH(2)PO(4) adjusted pH 3.5, 16:84, v/v) at flow rate of 1.5mlmin(-1), and then separated on the analytical column (Ultimate XB-C(18), 4.6mmx50mm, 5microm).The complete cycle of the on-line SPE preconcentration purification and HPLC separation of the analytes was 5min. Calibration curves with good linearities (r=0.9994 for plasma sample and r=0.9988 for urine sample) were obtained in the range 0.02-5microgml(-1) in plasma and 0.05-10microg ml(-1) in urine for faropenem. The optimized method showed good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. The method was successfully utilized to quantify faropenem in human plasma and urine to support the clinical pharmacokinetic studies. Copyright 2009 Elsevier B.V. All rights reserved.

  16. Development of isotope labeling liquid chromatography mass spectrometry for mouse urine metabolomics: quantitative metabolomic study of transgenic mice related to Alzheimer's disease.

    PubMed

    Peng, Jun; Guo, Kevin; Xia, Jianguo; Zhou, Jianjun; Yang, Jing; Westaway, David; Wishart, David S; Li, Liang

    2014-10-03

    Because of a limited volume of urine that can be collected from a mouse, it is very difficult to apply the common strategy of using multiple analytical techniques to analyze the metabolites to increase the metabolome coverage for mouse urine metabolomics. We report an enabling method based on differential isotope labeling liquid chromatography mass spectrometry (LC-MS) for relative quantification of over 950 putative metabolites using 20 μL of urine as the starting material. The workflow involves aliquoting 10 μL of an individual urine sample for ¹²C-dansylation labeling that target amines and phenols. Another 10 μL of aliquot was taken from each sample to generate a pooled sample that was subjected to ¹³C-dansylation labeling. The ¹²C-labeled individual sample was mixed with an equal volume of the ¹³C-labeled pooled sample. The mixture was then analyzed by LC-MS to generate information on metabolite concentration differences among different individual samples. The interday repeatability for the LC-MS runs was assessed, and the median relative standard deviation over 4 days was 5.0%. This workflow was then applied to a metabolomic biomarker discovery study using urine samples obtained from the TgCRND8 mouse model of early onset familial Alzheimer's disease (FAD) throughout the course of their pathological deposition of beta amyloid (Aβ). It was showed that there was a distinct metabolomic separation between the AD prone mice and the wild type (control) group. As early as 15-17 weeks of age (presymptomatic), metabolomic differences were observed between the two groups, and after the age of 25 weeks the metabolomic alterations became more pronounced. The metabolomic changes at different ages corroborated well with the phenotype changes in this transgenic mice model. Several useful candidate biomarkers including methionine, desaminotyrosine, taurine, N1-acetylspermidine, and 5-hydroxyindoleacetic acid were identified. Some of them were found in previous metabolomics studies in human cerebrospinal fluid or blood samples. This work illustrates the utility of this isotope labeling LC-MS method for biomarker discovery using mouse urine metabolomics.

  17. Evaluation of the appropriate time period between sampling and analyzing for automated urinalysis

    PubMed Central

    Dolscheid-Pommerich, Ramona C.; Klarmann-Schulz, Ute; Conrad, Rupert; Stoffel-Wagner, Birgit; Zur, Berndt

    2016-01-01

    Introduction Preanalytical specifications for urinalysis must be strictly adhered to avoid false interpretations. Aim of the present study is to examine whether the preanalytical factor ‘time point of analysis’ significantly influences stability of urine samples for urine particle and dipstick analysis. Materials and methods In 321 pathological spontaneous urine samples, urine dipstick (Urisys™2400, Combur-10-Test™strips, Roche Diagnostics, Mannheim, Germany) and particle analysis (UF-1000 i™, Sysmex, Norderstedt, Germany) were performed within 90 min, 120 min and 240 min after urine collection. Results For urine particle analysis, a significant increase in conductivity (120 vs. 90 min: P < 0.001, 240 vs. 90 min: P < 0.001) and a significant decrease in WBC (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), RBC (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), casts (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001) and epithelial cells (120 vs. 90 min P = 0.610, 240 vs. 90 min P = 0.041) were found. There were no significant changes for bacteria. Regarding urine dipstick analysis, misclassification rates between measurements were significant for pH (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), leukocytes (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), nitrite (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), protein (120 vs. 90 min P < 0.001, 240 vs. 90 min P<0.001), ketone (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), blood (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), specific gravity (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001) and urobilinogen (120 vs. 90 min, P = 0.031). Misclassification rates were not significant for glucose and bilirubin. Conclusion Most parameters critically depend on the time window between sampling and analysis. Our study stresses the importance of adherence to early time points in urinalysis (within 90 min). PMID:26981022

  18. Urinary free cortisol assessment by liquid chromatography tandem mass spectrometry: a case study of ion suppression due to unacquainted administration of piperacillin

    PubMed Central

    Danese, Elisa; Salvagno, Gian Luca; Guzzo, Alessandra; Scurati, Samuele; Fava, Cristiano; Lippi, Giuseppe

    2017-01-01

    Introduction Liquid chromatography coupled to atmospheric pressure ionization tandem mass spectrometry (LC-ESI-MS/MS) is currently considered the reference method for quantitative determination of urinary free cortisol (UFC). One of the major drawbacks of this measurement is a particular form of matrix effect, conventionally known as ion suppression. Materials and methods We describe here the case of a 66-year-old-patient referred to the daily service of general medicine for intravenous antibiotic administration due to a generalized Staphylococcus aureus infection and for routine 24 hours UFC monitoring in the setting of glucocorticoid replacement therapy. Results The observation of 10-fold decrease of internal standard of cortisol signal led us to hypothesize the presence of an ion suppression effect due to a co-eluting endogenous compound. Screening analysis of tandem mass spectrometry (MS/MS) spectra of the interfering molecule, along with in vitro confirmation analyses, were suggestive of the presence of high concentration of piperacillin. The problem was then easily solved with minor modifications of the chromatographic technique. Conclusions According to our findings, antibiotic therapy with piperacillin/tazobactam should be regarded as an important interference in UFC assessment, which may potentially affect detection capability, precision and accuracy of this measurement. This case report emphasizes that accurate anamnesis and standardization of all phases of urine collection are essential aspects for preventing potential interference in laboratory testing. PMID:29180920

  19. Epidemiological investigation of the UGT2B17 polymorphism in doping control urine samples and its correlation to T/E ratios.

    PubMed

    Anielski, Patricia; Simmchen, Juliane; Wassill, Lars; Ganghofner, Dirk; Thieme, Detlef

    2011-10-01

    The deletion polymorphism of the enzyme UGT2B17 is known to correlate with the level of the testosterone to epitestosterone (T/E) ratio in urine specimen. Due to the importance of the T/E ratio to detect testosterone abuse in doping analysis, a PCR-ELISA system (Genotype® UGT test, AmplexDiagnostics) was established to identify the UGT2B17 phenotype in urine samples. Epidemiological investigations in a set of 674 routine doping controls (in- and out-of-competition) resulted in 22.8% homozygote gene-deleted and 74.5% UGT2B17-positive athletes. The validated test system has shown to be robust and sensitive: in only 18 cases (2.7%) isolation of cell material from urine failed. Following hydrolysis of glucuronidated conjugates, steroids were analyzed as bis-TMS derivatives by gas chromatography-mass spectrometry (GC-MS), for example, testosterone (T) and epitestosterone (E). Additionally, isotope ration mass spectrometry (IRMS) analysis and luteinizing hormone (LH) measurement were applied. Mean T/E ratios significantly correlated with the UGT2B17 phenotype (del: T/E 0.9; pos: 1.7), however the values did not differ as distinctive as reported in previous studies. Additionally, the T/E ratios in the gene-deleted group did not show a normal curve of distribution (median of T/E 0.5). Obviously, beside the UGT2B17 deletion further influences have to be taken into account, for example, polymorphisms or induction of other metabolizing enzymes. Our results indicate that the UGT2B17 polymorphism might be insufficient when utilized solely as a crucial parameter for individual interpretation of T/E in urine. Nevertheless, the detection of the UGT2B17-gene deletion in urine samples would provide additional information important for gathering evidence in analysis of steroids in doping control. Copyright © 2011 John Wiley & Sons, Ltd.

  20. Urine testing for designer steroids by liquid chromatography with androgen bioassay detection and electrospray quadrupole time-of-flight mass spectrometry identification.

    PubMed

    Nielen, Michel W F; Bovee, Toine F H; van Engelen, Marcel C; Rutgers, Paula; Hamers, Astrid R M; van Rhijn, J Hans A; Hoogenboom, L Ron A P

    2006-01-15

    New anabolic steroids show up occasionally in sports doping and in veterinary control. The discovery of these designer steroids is facilitated by findings of illicit preparations, thus allowing bioactivity testing, structure elucidation using NMR and mass spectrometry, and final incorporation in urine testing. However, as long as these preparations remain undiscovered, new designer steroids are not screened for in routine sports doping or veterinary control urine tests since the established GC/MS and LC/MS/MS methods are set up for the monitoring of a few selected ions or MS/MS transitions of known substances only. In this study, the feasibility of androgen bioactivity testing and mass spectrometric identification is being investigated for trace analysis of designer steroids in urine. Following enzymatic deconjugation and a generic solid-phase extraction, the samples are analyzed by gradient LC with effluent splitting toward two identical 96-well fraction collectors. One well plate is used for androgen bioactivity detection using a novel robust yeast reporter gene bioassay yielding a biogram featuring a 20-s time resolution. The bioactive wells direct the identification efforts to the corresponding well numbers in the duplicate plate. These are subjected to high-resolution LC using a short column packed with 1.7-microm C18 material and coupled with electrospray quadrupole time-of-flight mass spectrometry (LC/QTOFMS) with accurate mass measurement. Element compositions are calculated and used to interrogate electronic substance databases. The feasibility of this approach for doping control is demonstrated via the screening of human urine samples spiked with the designer anabolic steroid tetrahydrogestrinone. Application of the proposed methodology, complementary to the established targeted urine screening for known anabolics, will increase the chance of finding unknown emerging designer steroids, rather then being solely dependent on findings of the illicit preparations themselves.

Top