Senzolo, C; Frignani, S; Pavoni, B
2001-07-01
An exposure risk assessment of workers in a refinery production unit was undertaken. Gasoline and its main components were investigated through environmental and biological monitoring. Measured variables were environmental benzene, toluene, pentane and hexane; benzene and toluene in blood and urine; tt-MA (metabolite of benzene) in urine. Multivariate statistical analysis of the data showed that worker's exposure to the above substances fell within the limits specified by organisations such as ACGIH. Also, biological values complied with reference values (RV) for non-occupationally-exposed population. Different values of biological variables were determined by separating smokers from non-smokers: smokers had hematic and urinary benzene values significantly higher than non-smokers. During a 3-yr sampling, it was possible to identify a significant decrease of benzene in the workplace air and of hematic benzene for non-smokers. The most exposed department, one in which tank-lorries were loaded, needs further investigation and extended monitoring.
Solid-Phase Extraction of Sulfur Mustard Metabolites Using an Activated Carbon Fiber Sorbent.
Lee, Jin Young; Lee, Yong Han
2016-01-01
A novel solid-phase extraction method using activated carbon fiber (ACF) was developed and validated. ACF has a vast network of pores of varying sizes and microporous structures that result in rapid adsorption and selective extraction of sulfur mustard metabolites according to the pH of eluting solvents. ACF could not only selectively extract thiodiglycol and 1-methylsulfinyl-2-[2-(methylthio)-ethylsulfonyl]ethane eluting a 9:1 ratio of dichloromethane to acetone, and 1,1'-sulfonylbis[2-(methylsulfinyl)ethane] and 1,1'-sulfonylbis- [2-S-(N-acetylcysteinyl)ethane] eluting 3% hydrogen chloride in methanol, but could also eliminate most interference without loss of analytes during the loading and washing steps. A sample preparation method has been optimized for the extraction of sulfur mustard metabolites from human urine using an ACF sorbent. The newly developed extraction method was applied to the trace analysis of metabolites of sulfur mustard in human urine matrices in a confidence-building exercise for the analysis of biomedical samples provided by the Organisation for the Prohibition of Chemical Weapons. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Van Thuyne, W; Delbeke, F T
2006-09-01
Caffeine concentrations were measured in the urine of 4633 athletes tested for doping control in the Ghent Doping Control Laboratory in 2004. Determination of these concentrations was done using an alkaline extraction with a mixture of dichloromethane and methanol (9 : 1; v/v) followed by high performance liquid chromatography and ultraviolet detection (HPLC-UV). The method was validated according to ISO 17 025 standards (International Organisation for Standardisation). Quantification was done by using a linear calibration curve in the range from 0 to 20 microg/ml. The limit of quantification (LOQ) was 0.10 microg/ml. Because the results were not normally distributed, transformation of the data was done to evaluate the difference in detected concentrations in several sports. This resulted in an overall average concentration of 1.12 +/- 2.68 microg/ml. Comparison of the most frequently tested sports in 2004 demonstrated that caffeine concentrations in samples originating from power lifters are significantly higher in comparison to urines taken in other sports. Also, a significant difference between caffeine concentrations found in cycling and concentrations found in other sports, including athletics and some ball sports, was observed. A comparison was made between results obtained in 2004 and results obtained before the removal of caffeine from the WADA (World Anti-Doping Agency) doping list indicating that average caffeine concentrations decreased after the withdrawal of caffeine from the list of prohibited substances. The overall percentage of positive samples between the two periods remained the same although the percentage of positive samples noticed in cycling increased after the removal of caffeine from the doping list.
Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing
Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre
2016-01-01
The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899
Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.
Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre
2016-05-17
The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.
NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, S; Brian Culligan, B
2007-08-28
The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides andmore » strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.« less
Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration
Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang
2015-01-01
Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. Conclusions The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease. PMID:26353117
Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.
Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang
2015-01-01
The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.
CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)
This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...
Urine uroporphyrin; Urine coproporphyrin; Porphyria - uroporphyrin ... After you provide a urine sample, it is tested in the lab. This is called a random urine sample. If needed, your health care provider ...
Haid, Bernhard; Roesch, Judith; Strasser, Christa; Oswald, Josef
2017-10-01
The likelihood of detecting vesicoureteral reflux (VUR) after febrile urinary tract infections (UTI) in children logically should correlate with the correct diagnosis of the UTI. Beneath the unspecific symptoms of fever urine analysis is the main diagnostic criterion for the exact diagnosis of febrile UTIs in children. Use of inadequate urine sampling techniques during diagnosis may lead to impaired accuracy in UTI diagnosis. This could lead to the assumption that children, having diagnosed their UTI by the use of possibly inadequate urine sampling techniques should not be evaluated as consequently compared to those, where the diagnosis relied on sterile urine sampling techniques. We hypothesized that children with possibly contaminated urine samples during the initial diagnosis may show a lower rate of VUR in subsequent VCUGs because of a wrong diagnosis initially compared to children, where accurate urine sampling techniques were used. Between 2009 and 2014, a total of 555 patients underwent a primary VCUG at our department indicated because of febrile UTIs. Patients with urine collection methods other than bag urine and catheter/suprapubic aspiration (SPA) were excluded from this study (mid-stream urine, potty urine, n = 149). We evaluated 402 patients (male/female 131/271, mean age 1.91 years), VUR rates and grades were compared between patients where urine was sampled by the use of a urine bag only at the time of diagnosis (n = 296, 73.6%) and those where sterile urine sampling (catheter, suprapubic puncture) was performed (n = 106, 26.3%). 4 patients were excluded due to equivocal data on urine sampling. VUR rate in children after sterile urine sampling using a catheter or SPA accounted to 31.1%. In those where urine samples acquired by the use of urine bags were used, 33.7% showed VUR on subsequent VCUG (p = 0.718). There were no significant differences as to VUR grades or gender, although VUR was much more commonly diagnosed in female patients (37.0% vs 28.2%, p = 0.227) (Figure). Children diagnosed with their UTI by use of bag urine in our experience carried the same risk of showing a VUR in a subsequent VCUG compared to those, where the initial diagnosis relied - beneath clinical criteria - on urine samples acquired by suprapubic puncture or catheterization. Consequently urine-sampling technique during initial UTI diagnosis alone should not be used as predictor for the reliability of UTI diagnosis and should not influence the further management after UTI. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure
Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta
2018-01-01
Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162
Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.
Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta
2017-01-01
Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
A "clean-catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head ... water and rinse well. A small amount of urine should initially fall into the toilet bowl before ...
Comparison of routine urinalysis and urine Gram stain for detection of bacteriuria in dogs.
Way, Leilani Ireland; Sullivan, Lauren A; Johnson, Valerie; Morley, Paul S
2013-01-01
To determine the utility of performing urine Gram stain for detection of bacteriuria compared to routine urine sediment examination and bacterial aerobic urine culture. Prospective, observational study. University teaching hospital. Urine samples acquired via cystocentesis through convenience sampling from 103 dogs presenting to a tertiary referral institution. All samples underwent routine urinalysis, including sediment examination, as well as urine Gram stain and quantitative bacterial aerobic urine culture. The urine Gram stain demonstrated improved sensitivity (96% versus 76%), specificity (100% versus 77%), positive predictive value (100% versus 83%), and negative predictive value (93% versus 69%) when identifying bacteriuria, compared to routine urine sediment examination. The urine Gram stain is highly sensitive and specific when detecting the presence of bacteria in canine urine samples. Gram staining should be considered when bacteriuria is highly suspected and requires rapid identification while bacterial culture is pending. © Veterinary Emergency and Critical Care Society 2013.
Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi
2016-02-01
Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62 mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.
Andersen, Stig; Waagepetersen, Rasmus; Laurberg, Peter
2015-05-14
Iodine nutrition is commonly assessed from iodine excretion in urine. A 24 h urine sample is ideal, but it is cumbersome and inconvenient. Hence, spot urine samples with creatinine to adjust for differences in void volume are widely used. Still, the importance of ethnicity and the timing of spot urine samples need to be settled. We, thus, collected 104 early morning spot urine samples and 24 h urine samples from Inuit and non-Inuit living in Greenland. Diet was assessed by a FFQ. Demographic data were collected from the national registry and by questionnaires. Iodine was measured using the Sandell-Kolthoff reaction, creatinine using the Jaffe method and para-amino benzoic acid by the HPLC method for the estimation of completeness of urine sampling and compensation of incomplete urine samples to 24 h excretion. A population-based recruitment was done from the capital city, a major town and a settlement (n 36/48/20). Participants were seventy-eight Inuit and twenty-six non-Inuit. The median 24 h iodine excretion was 138 (25th-75th percentile 89-225) μg/97 (25th-75th percentile 72-124) μg in Inuit/non-Inuit (P= 0.030), and 153 (25th-75th percentile 97-251) μg/102 (25th-75th percentile 73-138) μg (P= 0.026) when including compensated iodine excretion. Iodine excretion in 24 h urine samples increased with a rising intake of traditional Inuit foods (P= 0.005). Iodine excretion was lower in morning spot urine samples than in 24 h urine samples (P< 0.001). This difference was associated with iodine intake levels (P< 0.001), and was statistically significant when the iodine excretion level was above 150 μg/24 h. In conclusion, the iodine intake level was underestimated from morning spot urine samples if iodine excretion was above the recommended level.
Stability of cannabinoids in urine in three storage temperatures.
Golding Fraga, S; Díaz-Flores Estévez, J; Díaz Romero, C
1998-01-01
Stability of cannabinoid compounds in urine samples were evaluated using several storage temperatures. Appreciable losses (> 22.4 percent) were observed in some urine samples, after being stored at room temperature for 10 days. Lower losses (8.1 percent) were observed when the urine samples were refrigerated for 4 weeks. The behavior of urine samples depended on the analyzed urine. This could be due to the different stability of the cannabinoids present in each urine sample. Important losses of 8.0 +/- 10.6, 15.8 +/- 4.2, and 19.6 +/- 6.7 percent were found when the urine samples were frozen during 40 days, 1 year, and 3 years, respectively. Average losses (> > 5 percent) can be observed after one day which could mainly be due to the decrease of the solubility of 11-nor-U9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) or adsorption process of cannabinoid molecules to the plastic storage containers.
Substitution of human for horse urine disproves an accusation of doping*.
Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo
2008-09-01
In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.
Thormahlen's test; Melanin - urine ... A clean-catch urine sample is needed. ... this substance that it shows up in the urine. ... Normally, melanin is not present in urine. Normal value ranges may ... measurements or test different samples. Talk to your health ...
Yuste, Rosario Sanchez; Frías, Carolina; López, Ana; Vallejo, Carlos; Martín, Paloma; Bellas, Carmen
2008-01-01
To compare the diagnostic value of cytology and immunohistochemistry staining (IHS) of urine samples for polyomavirus reactivation diagnosis. Sixty-eight urine samples collected from 18 immunosuppressed patients were analyzed by Papanicolaou and IHS with a JC/BK virus-specific monoclonal antibody. Overall, polyomavirus BK (BKV) was positive in 11 of 18 patients (61.1%) (3 of whom developed hemorrhagic cystitis) and in 23 of 68 urine samples (28%). Of 23 samples, 4 (17%) were positive by 1 of the 2 techniques, only. Of 23 samples, 19 (83%) were positive by both methods. In matching urine samples from the same patient, the number of BKV-infected positive cells detected by IHS in urine slides was higher than those detected by Papanicolaou staining (71.3%). The main advantage of LHS is that it allowed confirmation of BKV infection diagnosis in urine samples. IHS detected more BKV-infected cells in samples with few positive urothelial cells, which would have gone undetected if only Papanicolaou staining had been used as the BKV screening method. Urine samples testing for BKV by both techniques will improve diagnosis in asymptomatic patients, allowing early therapeutic intervention and a better clinical outcome.
Basic or extended urine sampling to analyse urine production?
Denys, Marie-Astrid; Kapila, Vansh; Weiss, Jeffrey; Goessaert, An-Sofie; Everaert, Karel
2017-09-01
Frequency volume charts are valuable tools to objectify urine production in patients with nocturia, enuresis or nocturnal incontinence. Analyses of daytime and nighttime urine (=basic collection) or analyses of urine samples collected every 3 h (=extended collection) extend this evaluation by describing circadian patterns of water and solute diuresis (=renal function profiles). To assess intra-individual correlation and agreement between renal function profiles provided using basic and extended urine collections, and using two extended urine collections. To create a short-form of the extended collection. This prospective observational study was executed at Ghent University Hospital, Belgium. Study participation was open for anyone visiting the hospital. Participants collected one basic and two extended 24-h urine collections. Urinary levels of osmolality, sodium and creatinine were determined. There was a moderate to strong correlation between results of basic and extended urinalyses. Comparing both extended urinalyses showed a moderate correlation between the eight individual samples and a weak to strong correlation between the mean daytime and nighttime values of renal functions. Different samples could be considered as most representative for mean daytime values, while all samples collected between 03 and 05am showed the highest agreement with mean nighttime values of renal function. Since there is a good correlation and agreement between basic and extended urine collections to study the mechanisms underlying urine production, the choice of urine sampling method to evaluate urine production depends on the purpose. A nighttime-only urine sample collected between 03 and 05am may be the most practical approach. © 2017 Wiley Periodicals, Inc.
Effects of diet composition on mutagenic activity in urine.
Ohara, Akihiro; Matsuhisa, Tsugio
2004-01-01
The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.
Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige
2016-08-01
Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.
Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil
2017-07-01
Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.
Huang, Liping; Crino, Michelle; Wu, Jason H Y; Woodward, Mark; Barzi, Federica; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Neal, Bruce
2016-02-01
Estimating equations based on spot urine samples have been identified as a possible alternative approach to 24-h urine collections for determining mean population salt intake. This review compares estimates of mean population salt intake based upon spot and 24-h urine samples. We systematically searched for all studies that reported estimates of daily salt intake based upon both spot and 24-h urine samples for the same population. The associations between the two were quantified and compared overall and in subsets of studies. A total of 538 records were identified, 108 were assessed as full text and 29 were included. The included studies involved 10,414 participants from 34 countries and made 71 comparisons available for the primary analysis. Overall average population salt intake estimated from 24-h urine samples was 9.3 g/day compared with 9.0 g/day estimated from the spot urine samples. Estimates based upon spot urine samples had excellent sensitivity (97%) and specificity (100%) at classifying mean population salt intake as above or below the World Health Organization maximum target of 5 g/day. Compared with the 24-h samples, estimates based upon spot urine overestimated intake at lower levels of consumption and underestimated intake at higher levels of consumption. Estimates of mean population salt intake based upon spot urine samples can provide countries with a good indication of mean population salt intake and whether action on salt consumption is required. Published by Oxford University Press on behalf of the International Epidemiological Association 2015. This work is written by US Government employees and is in the public domain in the US.
Estimating mean change in population salt intake using spot urine samples.
Petersen, Kristina S; Wu, Jason H Y; Webster, Jacqui; Grimes, Carley; Woodward, Mark; Nowson, Caryl A; Neal, Bruce
2017-10-01
Spot urine samples are easier to collect than 24-h urine samples and have been used with estimating equations to derive the mean daily salt intake of a population. Whether equations using data from spot urine samples can also be used to estimate change in mean daily population salt intake over time is unknown. We compared estimates of change in mean daily population salt intake based upon 24-h urine collections with estimates derived using equations based on spot urine samples. Paired and unpaired 24-h urine samples and spot urine samples were collected from individuals in two Australian populations, in 2011 and 2014. Estimates of change in daily mean population salt intake between 2011 and 2014 were obtained directly from the 24-h urine samples and by applying established estimating equations (Kawasaki, Tanaka, Mage, Toft, INTERSALT) to the data from spot urine samples. Differences between 2011 and 2014 were calculated using mixed models. A total of 1000 participants provided a 24-h urine sample and a spot urine sample in 2011, and 1012 did so in 2014 (paired samples n = 870; unpaired samples n = 1142). The participants were community-dwelling individuals living in the State of Victoria or the town of Lithgow in the State of New South Wales, Australia, with a mean age of 55 years in 2011. The mean (95% confidence interval) difference in population salt intake between 2011 and 2014 determined from the 24-h urine samples was -0.48g/day (-0.74 to -0.21; P < 0.001). The corresponding result estimated from the spot urine samples was -0.24 g/day (-0.42 to -0.06; P = 0.01) using the Tanaka equation, -0.42 g/day (-0.70 to -0.13; p = 0.004) using the Kawasaki equation, -0.51 g/day (-1.00 to -0.01; P = 0.046) using the Mage equation, -0.26 g/day (-0.42 to -0.10; P = 0.001) using the Toft equation, -0.20 g/day (-0.32 to -0.09; P = 0.001) using the INTERSALT equation and -0.27 g/day (-0.39 to -0.15; P < 0.001) using the INTERSALT equation with potassium. There was no evidence that the changes detected by the 24-h collections and estimating equations were different (all P > 0.058). Separate analysis of the unpaired and paired data showed that detection of change by the estimating equations was observed only in the paired data. All the estimating equations based upon spot urine samples identified a similar change in daily salt intake to that detected by the 24-h urine samples. Methods based upon spot urine samples may provide an approach to measuring change in mean population salt intake, although further investigation in larger and more diverse population groups is required. © The Author 2016; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association
Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia
2005-01-01
A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.
Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M
2017-04-08
Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.
Gravitt, Patti E.; Dunn, S. Terence; Brown, David; Allen, Richard A.; Eby, Yolanda J.; Smith, Katie; Zuna, Rosemary E.; Zhang, Roy R.; Gold, Michael A.; Schiffman, Mark; Walker, Joan L.; Castle, Philip E.; Wentzensen, Nicolas
2014-01-01
While urine-based sampling for human papillomavirus (HPV) is being explored as a simple and noninvasive approach for cervical cancer screening, data comparing HPV genotyping in urine and those in cellular sampling of the cervix and vulva, and their correlation with rigorously confirmed cervical disease status, are sparse. We performed HPV genotyping on voided-urine and clinician-collected vulvar and cervical samples from 72 women undergoing colposcopy. Although urine-based HPV carcinogenic HPV detection was lower (58.3%) than cervical (73.6%) and vulvar (72.1%) detection (P = 0.05 and 0.07, respectively), the agreement of urine HPV with cervical and vulvar HPV was moderate (kappa = 0.55) and substantial (kappa = 0.62), respectively. Urine-based carcinogenic HPV detection had a clinical sensitivity of 80.8% (95% confidence interval [CI] = 60.7 to 93.5) and a specificity of 53.3% (95% CI = 37.9 to 68.3) for diagnosing cervical intraepithelial neoplasia grades 2/3 (CIN2/3) on histology; 90.0% of CIN3 was positive for urine HPV. The corresponding sensitivity and specificity values for vulvar sampling were 92% (95% CI = 74 to 99) and 40.5% (95% CI = 25.6 to 56.7), and those for cervical sampling were 96.2% (95% CI = 80.4 to 99.9) and 40% (95% CI = 25.7 to 55.7), respectively. HPV16 was the most common carcinogenic genotype detectable in 25% of urine, 33.8% of vulvar, and 31.9% of cervical samples overall, with prevalence increasing with cervical disease grade, regardless of the sampling method. Stronger cervical HPV PCR signal strengths were associated with increased frequency of urine HPV detection. In summary, the relatively lower detection rates but comparable clinical performance of urine-based HPV sampling underscore the need for larger studies to evaluate urine-based sampling for cervical cancer screening, epidemiologic studies, and postvaccination HPV disease surveillance. PMID:24197879
Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam
2017-05-01
Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV detection in urine. Thus, urine samples may be an effective alternative for HPV detection in women who hesitate to participate in cervical cancer screening programs. Copyright © 2017 Elsevier B.V. All rights reserved.
Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.
Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P
2014-11-01
The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.
Bordelon, Hali; Ricks, Keersten M.; Pask, Megan E.; Russ, Patricia K.; Solinas, Francesca; Baglia, Mark L.; Short, Philip A.; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W.; Haselton, Frederick R.; Pettit, April C.
2017-01-01
Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1 milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5 mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found a increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. PMID:28285168
Bordelon, Hali; Ricks, Keersten M; Pask, Megan E; Russ, Patricia K; Solinas, Francesca; Baglia, Mark L; Short, Philip A; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W; Haselton, Frederick R; Pettit, April C
2017-05-01
Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found an increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. Copyright © 2017 Elsevier B.V. All rights reserved.
Pratumvinit, Busadee; Reesukumal, Kanit; Wongkrajang, Preechaya; Khejonnit, Varanya; Klinbua, Cherdsak; Dangneawnoi, Weerapol
2013-11-15
Acidification of urine has been recommended before testing for calcium, phosphate, and magnesium. We investigated the necessity of pre-analytical acidification in both crystallized and non-crystallized urine samples. From 130 urine samples obtained via routine urine analysis, 65 (50%) samples were classified as non-crystallized. All samples were divided into three groups: untreated samples, acidified samples with HCl, and acidified samples after 1h room-temperature incubation. Urine samples were measured for calcium, phosphate, magnesium, and creatinine using Modular P800 and were examined for crystals using light microscopy. In crystallized samples, acidified samples with 1h incubation had significantly higher Ca/Cr, P/Cr, and Mg/Cr than did untreated samples with mean differences of 0.04, 0.03, and 0.01 mg/mg, respectively (P<0.001). In acidified samples that were analyzed immediately, crystallized samples had lower calcium concentrations than those of acidified samples with 1h incubation and a mean difference of 0.21 mg/dl (P = 0.025). None of the sample differences which exceeded the critical difference of urinary Ca, P and Mg was observed. Acidification of urine should be performed before the measurement of Ca, P, and Mg in the presence of urinary crystals. However, the lack of an acidification process does not result in a clinically significant change. © 2013.
Urine osmolality in the US population: Implications for environmental biomonitoring
Yeh, Hung-Chieh; Lin, Yu-Sheng; Kuo, Chin-Chi; Weidemann, Darcy; Weaver, Virginia; Fadrowski, Jeffrey; Neu, Alicia; Navas-Acien, Ana
2018-01-01
Background For many environmental chemicals, concentrations in spot urine samples are considered valid surrogates of exposure and internal dose. To correct for urine dilution, spot urine concentrations are commonly adjusted for urinary creatinine. There are, however, several concerns about the use of urine creatinine. While urine osmolality is an attractive alternative; its characteristics and determinants in the general population remain unknown. Our objective was to describe the determinants of urine osmolality and to contrast the difference between osmolality and creatinine in urine. Methods From the National Health and Nutrition Examination Survey (NHANES) 2009–2012, 10,769 participants aged 16 years or older with measured urine osmolality and creatinine were used in the analysis. Very dilute and very concentrated urine was defined as urine creatinine lower than 0.3 g/l and higher than 3 g/l, respectively. Linear and logistic regression analyses were performed to investigate the associations of interest. Results Urine osmolality and creatinine were highly correlated (Pearson correlation coefficient = 0.75) and their respective median values were 648 mOsm/kg and 1.07 g/l. The prevalence of very dilute and very concentrated urine samples was 8.1% and 3.1%, respectively. Factors associated in the same direction with both urine osmolality and urine creatinine included age, sex, race, body mass index (BMI), hypertension, water intake, and blood osmolality. The magnitude of associations expressed as percent change was significantly stronger with creatinine than osmolality. Compared to urine creatinine, urine osmolality did not vary by diabetes status but was affected by daily total protein intake. Participants with chronic kidney disease (CKD) had significantly higher urine creatinine concentrations but lower urine osmolality. Both very dilute and concentrated urine were associated with a diverse array of sociodemographic, medical conditions, and dietary factors. For instance, females were approximately 3.3 times more likely to have urine over-dilution than male [the adjusted odds ratios (95% CI) = 3.27 (2.10–5.10)]. Conclusion Although the determinants of urine osmolality were generally similar to those of urine creatinine, the relative influence of socio-demographic and medical conditions was less on urine osmolality than on urine creatinine. Protocols for spot urine sample collection could recommend avoiding excessive and insufficient water intake before urine sampling to improve urine adequacy. The feasibility of adopting urine osmolality adjustment and water intake recommendations before providing spot urine samples for environmental biomonitoring merits further investigation. PMID:25460670
Huang, Liping; Crino, Michelle; Wu, Jason Hy; Woodward, Mark; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Nowson, Caryl A; Elliott, Paul; Cogswell, Mary; Toft, Ulla; Mill, Jose G; Furlanetto, Tania W; Ilich, Jasminka Z; Hong, Yet Hoi; Cohall, Damian; Luzardo, Leonella; Noboa, Oscar; Holm, Ellen; Gerbes, Alexander L; Senousy, Bahaa; Pinar Kara, Sonat; Brewster, Lizzy M; Ueshima, Hirotsugu; Subramanian, Srinivas; Teo, Boon Wee; Allen, Norrina; Choudhury, Sohel Reza; Polonia, Jorge; Yasuda, Yoshinari; Campbell, Norm Rc; Neal, Bruce; Petersen, Kristina S
2016-09-21
Methods based on spot urine samples (a single sample at one time-point) have been identified as a possible alternative approach to 24-hour urine samples for determining mean population salt intake. The aim of this study is to identify a reliable method for estimating mean population salt intake from spot urine samples. This will be done by comparing the performance of existing equations against one other and against estimates derived from 24-hour urine samples. The effects of factors such as ethnicity, sex, age, body mass index, antihypertensive drug use, health status, and timing of spot urine collection will be explored. The capacity of spot urine samples to measure change in salt intake over time will also be determined. Finally, we aim to develop a novel equation (or equations) that performs better than existing equations to estimate mean population salt intake. A systematic review and meta-analysis of individual participant data will be conducted. A search has been conducted to identify human studies that report salt (or sodium) excretion based upon 24-hour urine samples and spot urine samples. There were no restrictions on language, study sample size, or characteristics of the study population. MEDLINE via OvidSP (1946-present), Premedline via OvidSP, EMBASE, Global Health via OvidSP (1910-present), and the Cochrane Library were searched, and two reviewers identified eligible studies. The authors of these studies will be invited to contribute data according to a standard format. Individual participant records will be compiled and a series of analyses will be completed to: (1) compare existing equations for estimating 24-hour salt intake from spot urine samples with 24-hour urine samples, and assess the degree of bias according to key demographic and clinical characteristics; (2) assess the reliability of using spot urine samples to measure population changes in salt intake overtime; and (3) develop a novel equation that performs better than existing equations to estimate mean population salt intake. The search strategy identified 538 records; 100 records were obtained for review in full text and 73 have been confirmed as eligible. In addition, 68 abstracts were identified, some of which may contain data eligible for inclusion. Individual participant data will be requested from the authors of eligible studies. Many equations for estimating salt intake from spot urine samples have been developed and validated, although most have been studied in very specific settings. This meta-analysis of individual participant data will enable a much broader understanding of the capacity for spot urine samples to estimate population salt intake.
Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.
Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar
2015-11-15
In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of sequestering contaminants from environmental release and allows for targeted treatment of potential health hazards prior to agricultural application. The efficacy of pathogen and pharmaceutical inactivation, transformation or removal during urine nutrient recovery processes is thus briefly reviewed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Reina, Jordi; Ballesteros, Francisca; Ruiz de Gopegui, Enrique; Munar, Maria; Mari, Margarita
2003-01-01
We report a prospective comparison of the efficacies of an indirect immunofluorescence assay (IFA) and shell vial culture (SVC) of throat swab and urine samples from patients with mumps. Throat swab samples were used for the IFA; the urine samples and throat swabs were inoculated into vials of Vero cells. We studied 62 patients by using 62 throat swabs and 50 urine samples (50 patients with both samples). Sixty (96.7%) throat samples were positive in the SVC, and 61 (98.3%) were positive in the IFA. For the 50 patients from whom both samples were available, the IFA was positive in 50 (100%) cases, the urine sample was positive in 49 (98%) cases, and the throat swab was positive in 48 (96%) cases (P > 0.05). This comparison of throat swabs and urine samples has shown that the two clinical samples are similar in efficacy. PMID:14605158
Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina
2016-09-01
Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.
A method for estimating radioactive cesium concentrations in cattle blood using urine samples.
Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji
2017-12-01
In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.
Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio
2013-01-01
Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.
Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan
2013-09-01
The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.
Effect of urine creatinine level during pregnancy on dipstick test.
Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori
2017-06-01
Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.
O'Brien, Kathryn; Stanton, Naomi; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C
2011-03-01
Due to the non-specific nature of symptoms of UTI in children and low levels of urine sampling, the prevalence of UTI amongst acutely ill children in primary care is unknown. To undertake an exploratory study of acutely ill children consulting in primary care, determine the feasibility of obtaining urine samples, and describe presenting symptoms and signs, and the proportion with UTI. Exploratory, observational study. Four general practices in South Wales. A total of 99 sequential attendees with acute illness aged less than five years. UTI defined by >10(5) organisms/ml on laboratory culture of urine. Urine samples were obtained in 75 (76%) children. Three (4%) met microbiological criteria for UTI. GPs indicated they would not normally have obtained urine samples in any of these three children. However, all had received antibiotics for suspected alternative infections. Urine sample collection is feasible from the majority of acutely ill children in primary care, including infants. Some cases of UTI may be missed if children thought to have an alternative site of infection are excluded from urine sampling. A larger study is needed to more accurately determine the prevalence of UTI in children consulting with acute illness in primary care, and to explore which symptoms and signs might help clinicians effectively target urine sampling.
Gouarne, C; Foury, A; Duclos, M
2004-10-01
Except immediate freezing of the samples, no practical method has been validated for preservation of glucocorticoids and catecholamines in 24-h urine collection. Furthermore, the influence of urine storage at bladder temperature during periods of different lengths and the effect of prior exercise on preservation of these hormones in the bladder have not been investigated until now. Ten healthy volunteers collected their urine both after a resting and after an exercise session. Urine was aliquoted into tubes which were stored during 24 h in the presence or in the absence of preservatives and at different temperatures. Two samples were stored either 3 or 9 h at 37 degrees C (bladder temperature) without additive. When collecting 24-h urine samples for glucocorticoids determination, sample can be stored at room temperature during the 24-h collection period without compromising glucocorticoids preservation. When collecting 24-h urine samples for catecholamines determination, samples have to be chilled without preservative during the whole of the collection period. If the samples have to be stored at room temperature, HCl should be used. Moreover, we report for the first time that catecholamines can be degraded in the bladder and therefore that subjects should urinate every 3 h during either a resting or an exercising day.
Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio
2013-01-01
Background Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples’ storage or conditions for handling and DNA preservation and extraction methods. Methodology/Principal Findings We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patientś urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Conclusions/Significance Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used. PMID:23613907
Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.
Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan
2017-12-01
Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.
Urine phenobarbital drug screening: potential use for compliance assessment in neonates.
Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P
2012-02-01
This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.
The effect of substrate composition and storage time on urine specific gravity in dogs.
Steinberg, E; Drobatz, K; Aronson, L
2009-10-01
The purpose of this study is to evaluate the effects of substrate composition and storage time on urine specific gravity in dogs. A descriptive cohort study of 15 dogs. The urine specific gravity of free catch urine samples was analysed during a 5-hour time period using three separate storage methods; a closed syringe, a diaper pad and non-absorbable cat litter. The urine specific gravity increased over time in all three substrates. The syringe sample had the least change from baseline and the diaper sample had the greatest change from baseline. The urine specific gravity for the litter and diaper samples had a statistically significant increase from the 1-hour to the 5-hour time point. The urine specific gravity from canine urine stored either on a diaper or in a non-absorbable litter increased over time. Although the change was found to be statistically significant over the 5-hour study period it is unlikely to be clinically significant.
Immunoglobulin electrophoresis - urine; Gamma globulin electrophoresis - urine; Urine immunoglobulin electrophoresis; IEP - urine ... A clean-catch urine sample is needed. The clean-catch method is used to prevent germs from the penis or vagina from getting ...
Scargill, J J; Reed, P; Kane, J
2013-01-01
Measurement of fractionated plasma or urine metadrenalines is the recommended screening test in the diagnosis of phaeochromocytoma, with clinical cut-offs geared towards diagnostic sensitivity. Current practice at Salford Royal Hospital is to add urine catecholamines onto samples with raised urine metadrenalines, with the aim of adding specificity to a diagnosis of phaeochromocytoma. This practice was reviewed by identifying a series of patients with raised urine metadrenalines who had catecholamines reflectively added. A total of 358 samples were identified from 242 patients, of which 228 had urine catecholamines measured. A diagnosis of 'phaeochromocytoma' (n = 41) or 'no phaeochromocytoma' (n = 90) was obtained in 131 of 228 patients, giving raised urine metadrenalines a positive predictive value for phaeochromocytoma of 31%. The finding of increased urine catecholamines in samples with raised urine metadrenalines increased specificity for phaeochromocytoma to 70%. However, 95% diagnostic specificity for phaeochromocytoma could be achieved by the introduction of a second cut-off for urine metadrenalines geared towards maximizing specificity. Consideration of the degree of increase in urine metadrenalines is a superior method of determining the likelihood of phaeochromocytoma than measurement of urine catecholamines.
Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.
Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E
2002-12-01
Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to <30% after more than 3 months. Bands were detected at 276 bp on ethidium bromide-stained agarose gels after amplification by a nested PCR. The specificity of bands for 32 of 33 samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.
Mirzaei, Asad; Ahmadipour, Fereshteh; Cannet, Arnaud; Marty, Pierre; Delaunay, Pascal; Perrin, Pascale; Dorkeld, Franck; Sereno, Denis; Akhoundi, Mohammad
2018-05-27
The diagnosis of leishmaniasis relies mainly on the use of invasive processes, to collect the biological material for detecting Leishmania parasites. Body fluids, which can be collected by non-invasive process, would greatly facilitate the leishmaniasis diagnosis. In the present study, we investigated the potency of urine immunoblotting to diagnose cutaneous and visceral leishmaniasis and we compared with routine molecular methods. A total of 80 samples, including 40 sera and their 40 corresponding urine samples were collected from 37 suspected patients with cutaneous and visceral leishmaniasis, and 3 healthy individuals (as control), in Ilam and Ardabil provinces of Iran. All sera and urine samples were analyzed, using immunoblotting. The confirmation of leishmaniasis infection was performed, using conventional and quantitative PCRs as well as by sequencing the amplicons. Among 37 suspected patients, 23 patients presented cutaneous lesions (CL) and 14 exhibited clinical symptoms reminiscent of visceral leishmaniasis (L. infantum). Among cutaneous patients, 15 were positive for zoonotic cutaneous leishmaniasis (L. major), and eight for anthroponotic cutaneous leishmaniasis (L. tropica). Molecular quantification of Leishmania parasites was performed on sera, urines and cutaneous biopsies of CL and VL patients, demonstrating that parasite load is lower in urines, compared to sera or biopsy. DNA can be detected in 20 out of 23 (86.9%) CL urine samples and in 13 out of 14 (92.8%) VL urine samples. Immunodetection analysis demonstrates that 22 out of 23 (95.6%) sera from CL patients and all patients suspected with VL are positive. For urine samples, 18 out of 23 (78.2%) urine of CL patients and 13 out of 14 (92.8%) urine of VL patients were positive, using Western blot. Therefore, immunodetection and molecular analysis using urine samples can be used as a diagnostic tool for surveying cutaneous and visceral leishmaniasis. Copyright © 2017. Published by Elsevier B.V.
Beta-HCG - urine; Human chorionic gonadotropin - urine; Pregnancy test - hCG in urine ... To collect a urine sample, you urinate into a special (sterile) cup. Home pregnancy tests require the test strip to be dipped into ...
Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I.; Dwyer, Karen M.; Saffery, Richard
2018-01-01
Aim To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. Background DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. Methods QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Results Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0–0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0–9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0–17.7μg/mL and 0–1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. Conclusion High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease. PMID:29462136
Lecamwasam, Ashani; Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I; Dwyer, Karen M; Saffery, Richard
2018-01-01
To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0-0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0-9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0-17.7μg/mL and 0-1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease.
Trace Chemical Analysis Methodology
1980-04-01
oxidation of nitrite-containing species. Calibration studies were then made in preparation for the analysis of unknown samples of nitrate in urine and...the procedure for nitrate determination was made on two types of samples : human urine , and drinking water from a city water supply. Five samples of...AND URINE Concentration Standard Sample type of NO3, ppm deviation Drinking water 1.29 ±0 04 1.20 ±0.09 1.29 ±0.14 1.15 ±0.08 0.88 ±0.07 Human urine
Patterson, Carly A; Bishop, Micah A; Pack, Julie D; Cook, Audrey K; Lawhon, Sara D
2016-01-15
To determine the impact of processing delay, temperature, and transport tube type on results of quantitative bacterial culture (QBC) of canine urine. Diagnostic test evaluation. 60 mL of pooled urine from 4 dogs, divided into six 10-mL aliquots. Urine aliquots were spiked with bacteria from 1 of 6 independent Escherichia coli cultures to achieve a target bacterial concentration of 10(5) CFUs/mL. One milliliter from each aliquot was transferred into 5 silicone-coated clot tubes (SCTs) and 5 urine transport tubes (UTTs). Samples were stored at 4°C (39°F) and 25°C (77°F) for 0, 8, and 24 hours, and then standard QBCs were performed. Median bacterial concentration for urine samples stored in a UTT for 24 hours at 4°C was lower than that for samples stored in an SCT under the same conditions. Conversely, a substantial decrease in median bacterial concentration was identified for samples stored for 24 hours in an SCT at 25°C, compared with the median concentration for samples stored in a UTT under the same conditions. Median bacterial concentration in samples stored in an SCT at 25°C for 24 hours (275 CFUs/mL) was less than the cutoff typically used to define clinically important bacteriuria by use of urine samples obtained via cystocentesis (ie, > 1,000 CFUs/mL). Canine urine samples submitted for immediate QBC should be transported in plain sterile tubes such as SCTs. When prolonged (24-hour) storage at room temperature is anticipated, urine samples should be transported in UTTs.
García-Coca, Marta; Gadea, Ignacio; Esteban, Jaime
2017-06-01
Urine culture is the gold standard for the diagnosis of urinary tract infections (UTI). The use of flow cytometry analyzers (FCA) prior to culture allows for the quantification and recognition of cell components in urine to be automated and makes it possible to relate these data to the urine pathogens subsequently identified in cultures. Urine samples were assessed with the Sysmex UF-1000i analyzer. Those that met the criteria for culture (> 25 leukocytes/μL or > 385 bacteria/μL) were subjected to quantitative urine culture on chromogenic agar. Counts of red blood cells (RBC), white blood cells (WBC), epithelial cells (EC), and the kind of microorganisms identified in cultures were evaluated. A total of 17,483 samples were processed by FCA. Of these, 9057 met the criteria for culture. Urine cultures were reduced by 48.2%. The most common urine pathogen was Escherichia coli (60.3%). Negative urine cultures were significantly (p < 0.001) associated with a lower WBC count than urine with E. coli, Klebsiella spp. and Proteus spp., but urine with Enterococcus spp. had a lower WBC than negative urine. Contaminated urine had a significantly (p < 0.001) lower WBC than urine with E. coli, Klebsiella spp. and Proteus spp., but no differences were found for Enterococcus spp. (p = 0.729). Negative urine cultures had significantly (p < 0.05) higher EC than all positive urine samples. Contaminated urine was associated (p < 0.001) with higher EC than cultures with E. coli and Klebsiella spp., in comparison with cultures with Enterococcus spp. (p = 0.091) and Proteus spp. (p = 0.251). The use of the Sysmex UF-1000i flow cytometer for screening urine samples allows for a reduction in the number of urine cultures. WBC values correlate well with the main urine pathogens related to UTI. The results observed for Enterococcus spp. suggest a low impact of these pathogens as a cause of UTI.
Calvano, C D; Aresta, A; Iacovone, M; De Benedetto, G E; Zambonin, C G; Battaglia, M; Ditonno, P; Rutigliano, M; Bettocchi, C
2010-03-11
Protein analysis in biological fluids, such as urine, by means of mass spectrometry (MS) still suffers for insufficient standardization in protocols for sample collection, storage and preparation. In this work, the influence of these variables on healthy donors human urine protein profiling performed by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was studied. A screening of various urine sample pre-treatment procedures and different sample deposition approaches on the MALDI target was performed. The influence of urine samples storage time and temperature on spectral profiles was evaluated by means of principal component analysis (PCA). The whole optimized procedure was eventually applied to the MALDI-TOF-MS analysis of human urine samples taken from prostate cancer patients. The best results in terms of detected ions number and abundance in the MS spectra were obtained by using home-made microcolumns packed with hydrophilic-lipophilic balance (HLB) resin as sample pre-treatment method; this procedure was also less expensive and suitable for high throughput analyses. Afterwards, the spin coating approach for sample deposition on the MALDI target plate was optimized, obtaining homogenous and reproducible spots. Then, PCA indicated that low storage temperatures of acidified and centrifuged samples, together with short handling time, allowed to obtain reproducible profiles without artifacts contribution due to experimental conditions. Finally, interesting differences were found by comparing the MALDI-TOF-MS protein profiles of pooled urine samples of healthy donors and prostate cancer patients. The results showed that analytical and pre-analytical variables are crucial for the success of urine analysis, to obtain meaningful and reproducible data, even if the intra-patient variability is very difficult to avoid. It has been proven how pooled urine samples can be an interesting way to make easier the comparison between healthy and pathological samples and to individuate possible differences in the protein expression between the two sets of samples. Copyright 2009 Elsevier B.V. All rights reserved.
Lund, Heidi Sjetne; Skogtun, Gaute; Sørum, Henning; Eggertsdóttir, Anna Vigdís
2015-10-01
A diagnosis of bacterial cystitis commonly relies on a positive microbiological culture demonstrating the presence of a significant number of colony-forming units/ml urine, as urine within the upper urinary tract, bladder and proximal urethra generally is considered sterile. Recent studies from human and veterinary medicine indicate the presence of non-culturable bacteria in culture-negative urine samples. The aim of the present study was to determine the occurrence of bacterial DNA in culture-negative urine samples from cats with signs of feline lower urinary tract disease (FLUTD) and healthy control cats by 16S ribosomal DNA PCR and subsequent sequencing. The study sample included 38 culture-negative urine samples from cats with FLUTD and 43 culture-negative samples from control cats. Eight culture-positive urine samples from cats with FLUTD were included as external positive controls in addition to negative reaction controls. Of possible methodological limitations, degradation of DNA due to storage, the use of non-sedimented urine for DNA isolation and lack of internal positive reaction controls should be mentioned. The positive controls were recognised, but occurrence of bacterial DNA in culture-negative urine from cats with or without signs of lower urinary tract disease was not demonstrated. However, considering the possible methodological limitations, the presence of bacterial DNA in the urine of culture-negative FLUTD cats cannot be excluded based on the present results alone. Therefore, a prospective study reducing the possibility of degradation of DNA due to storage, in combination with modifications enhancing the chance of detecting even lower levels of bacterial DNA in culture-negative samples, seems warranted. © ISFM and AAFP 2014.
Wegelin, Olivier; Bartels, Diny W M; Tromp, Ellen; Kuypers, Karel C; van Melick, Harm H E
2015-10-01
To evaluate the effects of cystoscopy on urine cytology and additional cytokeratin-20 (CK-20) staining in patients presenting with gross hematuria. For 83 patients presenting with gross hematuria, spontaneous and instrumented paired urine samples were analyzed. Three patients were excluded. Spontaneous samples were collected within 1 hour before cystoscopy, and the instrumented samples were tapped through the cystoscope. Subsequently, patients underwent cystoscopic evaluation and imaging of the urinary tract. If tumor suspicious lesions were found on cystoscopy or imaging, subjects underwent transurethral resection or ureterorenoscopy. Two blinded uropathological reviewers (DB, KK) evaluated 160 urine samples. Reference standards were results of cystoscopy, imaging, or histopathology. Thirty-seven patients (46.3%) underwent transurethral resection or ureterorenoscopy procedures. In 30 patients (37.5%) tumor presence was confirmed by histopathology. The specificity of urine analysis was significantly higher for spontaneous samples than instrumented samples for both cytology alone (94% vs 72%, P = .01) and for cytology combined with CK-20 analysis (98% vs 84%, P = .02). The difference in sensitivity between spontaneous and instrumented samples was not significant for both cytology alone (40% vs 53%) and combined with CK-20 analysis (67% vs 67%). The addition of CK-20 analysis to cytology significantly increases test sensitivity in spontaneous urine cytology (67% vs 40%, P = .03). Instrumentation significantly decreases specificity of urine cytology. This may lead to unnecessary diagnostic procedures. Additional CK-20 staining in spontaneous urine cytology significantly increases sensitivity but did not improve the already high specificity. We suggest performing urine cytology and CK-20 analysis on spontaneously voided urine. Copyright © 2015 Elsevier Inc. All rights reserved.
Guan, Fuyu; Uboh, Cornelius E; Soma, Lawrence R; You, Youwen; Li, Xiaoqing; McDonnell, Sue
2012-01-01
19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts due to the analytical procedure. The present study was undertaken to determine whether NAED and nandrolone detected in plasma and urine samples collected from stallions are truly endogenous or artifacts from sample processing. To answer this question, fresh plasma and urine samples from ≥8 stallions were analyzed for the two AASs, soon after collection, by liquid chromatography hyphenated to tandem mass spectrometry (LC-MS/MS). NAED and nandrolone were not detected in fresh plasma samples but detected in the same samples post storage. Concentrations of both AASs increased with storage time, and the increases were greater at a higher storage temperature (37°C versus 4°C, and ambient temperature versus 4°C). Although NAED was detected in some fresh stallion urine samples, its concentration (<407 pg/mL) was far lower (<0.4%) than that in the same samples post storage (at ambient temperature for 15 days). Nandrolone was not detected in most of fresh urine samples but detected in the same samples post storage. Based on these results, it is concluded that all NAED and nandrolone detected in stored plasma samples of stallions and most of them in the stored urine samples are not from endogenous origins but spontaneously generated during sample storage, most likely from spontaneous decarboxylation of androstenedione-19-oic acid and testosterone-19-oic acid. To our knowledge, it is the first time that all NAED and nandrolone detected in plasma of stallions and most of them detected in the urine have been shown to be spontaneously generated in vitro during sample storage. This finding would have significant implications with regard to the regulation of the two steroids in horse racing. Copyright © 2011 Elsevier Ltd. All rights reserved.
Urinary Ca+2; Kidney stones - calcium in urine; Renal calculi - calcium in your urine; Parathyroid - calcium in urine ... A 24-hour urine sample is most often needed: On day 1, urinate into the toilet when you wake up in the morning. ...
Whitton, Clare; Gay, Gibson Ming Wei; Lim, Raymond Boon Tar; Tan, Linda Wei Lin; Lim, Wei-Yen; van Dam, Rob M
2016-08-01
The collection of 24-h urine samples for the estimation of sodium intake is burdensome, and the utility of spot urine samples in Southeast Asian populations is unclear. We aimed to assess the validity of prediction equations with the use of spot urine concentrations. A sample of 144 Singapore residents of Chinese, Malay, and Indian ethnicity aged 18-79 y were recruited from the Singapore Health 2 Study conducted in 2014. Participants collected urine for 24 h in multiple small bottles on a single day. To determine the optimal collection time for a spot urine sample, a 1-mL sample was taken from a random bottle collected in the morning, afternoon, and evening. Published equations and a newly derived equation were used to predict 24-h sodium excretion from spot urine samples. The mean ± SD concentration of sodium from the 24-h urine sample was 125 ± 53.4 mmol/d, which is equivalent to 7.2 ± 3.1 g salt. Bland-Altman plots showed good agreement at the group level between estimated and actual 24-h sodium excretion, with biases for the morning period of -3.5 mmol (95% CI: -14.8, 7.8 mmol; new equation) and 1.46 mmol (95% CI: -10.0, 13.0 mmol; Intersalt equation). A larger bias of 25.7 mmol (95% CI: 12.2, 39.3 mmol) was observed for the Tanaka equation in the morning period. The prediction accuracy did not differ significantly for spot urine samples collected at different times of the day or at a random time of day (P = 0.11-0.76). This study suggests that the application of both our own newly derived equation and the Intersalt equation to spot urine concentrations may be useful in predicting group means for 24-h sodium excretion in urban Asian populations. © 2016 American Society for Nutrition.
... tubular epithelial casts; Waxy casts; Casts in the urine; Fatty casts; Red blood cell casts; White blood ... The urine sample you provide may need to be from your first morning urine. The sample needs to be ...
... types of cells were found in your urine sample. You may need to repeat the test. Negative. This means no cancer cells were identified in your urine sample. Atypical. This indicates that some abnormalities were found ...
Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio.
Herrington, William; Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah
2016-10-07
Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long-term frozen storage at -80°C, -40°C, and -20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20-499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at -80°C or -40°C but not at -20°C. Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to -40°C or -80°C for 6 months before analysis also seem suitable. Copyright © 2016 by the American Society of Nephrology.
Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio
Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah
2016-01-01
Background and objectives Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Design, setting, participants, & measurements Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long–term frozen storage at −80°C, −40°C, and −20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Results Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20–499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at −80°C or −40°C but not at −20°C. Conclusions Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to −40°C or −80°C for 6 months before analysis also seem suitable. PMID:27654930
Almaani, Salem; Hebert, Lee A.; Rovin, Brad H.
2017-01-01
Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β-2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid–mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. PMID:28104821
Almaani, Salem; Hebert, Lee A; Rovin, Brad H; Birmingham, Daniel J
2017-05-01
Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β -2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid-mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. Copyright © 2017 by the American Society of Nephrology.
Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D
2017-09-01
Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.
Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard
2016-06-01
The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted. ©2015 Wiley Periodicals, Inc.
Urine protein; Albumin - urine; Urine albumin; Proteinuria; Albuminuria ... After you provide a urine sample, it is tested. The health care provider uses a dipstick made with a color-sensitive pad. The color change ...
Salina, Margarete Aparecida; Shikanai-Yasuda, Maria Aparecida; Mendes, Rinaldo Poncio; Barraviera, Benedito; Mendes Giannini, Maria José Soares
1998-01-01
For the diagnosis and follow-up of paracoccidioidomycosis patients undergoing therapy, we evaluated two methods (immunoblotting and competition enzyme immunoassay) for the detection of circulating antigen in urine samples. A complex pattern of reactivity was observed in the immunoblot test. Bands of 70 and 43 kDa were detected more often in urine samples from patients before treatment. The immunoblot method detected gp43 and gp70 separately or concurrently in 11 (91.7%) of 12 patients, whereas the competition enzyme immunoassay detected antigenuria in 9 (75%) of 12 patients. Both tests appeared to be highly specific (100%), considering that neither fraction detectable by immunoblotting was present in urine samples from the control group. gp43 remained present in the urine samples collected during the treatment period, with a significant decrease in reactivity in samples collected during clinical recovery and increased reactivity in samples collected during relapses. Reactivity of some bands was also detected in urine specimens from patients with “apparent cure.” The detection of Paracoccidioides brasiliensis antigens in urine appears to be a promising method for diagnosing infection, for evaluating the efficacy of treatment, and for detecting relapse. PMID:9620407
Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode.
Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj
2016-01-01
To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result. A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.
Collection and storage of urine specimens for measurement of urolithiasis risk factors.
Wu, Wenqi; Yang, Dong; Tiselius, Hans-Goran; Ou, Lili; Mai, Zanlin; Chen, Kang; Zhu, Hanliang; Xu, Shaohong; Zhao, Zhijian; Zeng, Guohua
2015-02-01
To evaluate how different methods for storage and preservation of urine samples affected the outcome of analysis of risk factors for stone formation. Spot urine samples were collected from 21 healthy volunteers. Each fresh urine sample was divided into ten 10-mL aliquots: 2 without preservative, 2 with thymol, 2 with toluene, 2 with hydrochloric acid (HCl), and 2 with sodium azide. One sample of each pair was stored at 4 °C and the other at room temperature. The concentrations of calcium, magnesium, sodium, phosphate, urate, oxalate, citrate, and pH in each urine sample were analyzed immediately after collection (0 hour) and after 24 and 48 hours. There were no significant differences in calcium, oxalate, magnesium, phosphate, sodium, urate or pH (without acidification) between samples with different preservation methods (P >.05). Urinary citrate, however, was significantly lower in the urine collected with HCl than when other preservatives were used, both at room temperature and at 4 °C. Urine pH was significantly higher after 48 hours than after 24 hours, whether the samples were stored at room temperature or at 4 °C. Antibacterial preservatives (eg, thymol or toluene) can be recommended as preservatives for 24-hour urine collections. Ideally, the samples should be stored at 4 °C. When HCl is used as a preservative, it seems essential to neutralize the samples before analysis. This is particularly obvious with the chromatographic method used for analysis of citrate that was used in this study. Copyright © 2015 Elsevier Inc. All rights reserved.
Vergara, Nicolás; Balanda, Monserrat; Hidalgo, Wilma; Martín, Héctor San; Aceituno, Alexis; Roldán, Francisco; Villalón, Tania; Hott, Melissa; Espinoza, Gloria; Quiero, Andrea; Valenzuela, María T; Ramírez, Eugenio
2018-04-01
Cervical cancer is the second most common malignant neoplasm in women worldwide representing approximately 10% of all types of cancers. Triage of women through cervical cytology has been an important strategy for the surveillance and control of new cases of cervical cancer. However, in many regions around the world cervical cytology has a low coverage compared to developed countries. The molecular detection of HPV is the most effective method to increase the screening sensitivity of women at risk of developing cervical cancer. There are very few studies about the efficacy of urine testing for detection of HPV in women followed up in primary health care centers. Consequently, the efficacy of using urine HPV screening in these populations has not been addressed yet. Here, we compared the detection of HPV in simultaneous urine and cervical samples of women followed up in primary health care centers. Urine and cervical samples were analyzed in 543 women attending at primary health care centers. HPV was detected by real time PCR, and HPV typing performed by PCR-RLB. A general HPV concordance of 86.2% (κ = 0.72) was determined between urine and cervical samples. The concordance for HPV-16 and 18 was almost perfect (κ = 0.82) and strong (κ = 0.77), respectively. The sensitivity and specificity for all HPV genotypes in urine using cervical samples as reference were 82.1 and 93.7%, respectively. The results showed that urine is a good alternative as clinical sample for HPV screening in women attending primary health care centers. Therefore, urine should be used as an alternative sample for increasing triage coverage either in refractory women participating in Pap surveillance programs or when cervical samples are not available.
Stratton-Phelps, Meri; House, John K
2004-10-01
To determine whether feeding a commercial anionic dietary supplement as a urinary acidifier to male goats may be useful for management of urolithiasis. 8 adult sexually intact male Toggenburg, Saanen, and Nubian goats. Goats were randomly assigned by age-, breed-, and weight-matched pairs to an oat or grass hay diet that was fed for 12 days. On days 13 to 14 (early sample collection time before supplementation), measurements were made of blood and urine sodium, potassium, calcium, magnesium, chloride, phosphorus, and sulfur concentrations; blood and urine pH; urine production; and water consumption. During the next 28 days, the anionic dietary supplement was added to the oat and grass hay diets to achieve a dietary cation-anion difference of 0 mEq/100g of dry matter. Blood and urine samples were analyzed during dietary supplementation on days 12 to 13 (middle sample collection time) and 27 to 28 (late sample collection time). Blood bicarbonate, pH, and urine pH of goats fed grass hay and goats fed oat hay were significantly decreased during the middle and late sample collection times, compared with the early sample collection time. Water consumption and urine production in all goats increased significantly during the late sample collection time, compared with the early sample collection time. The anionic dietary supplement used in our study increases urine volume, alters urine ion concentrations, and is an efficacious urinary acidifier in goats. Goats treated with prolonged anionic dietary supplementation should be monitored for secondary osteoporosis from chronic urinary calcium loss.
Sample preparation and storage can change arsenic speciation in human urine.
Feldmann, J; Lai, V W; Cullen, W R; Ma, M; Lu, X; Le, X C
1999-11-01
Stability of chemical speciation during sample handling and storage is a prerequisite to obtaining reliable results of trace element speciation analysis. There is no comprehensive information on the stability of common arsenic species, such as inorganic arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid, dimethylarsinic acid, and arsenobetaine, in human urine. We compared the effects of the following storage conditions on the stability of these arsenic species: temperature (25, 4, and -20 degrees C), storage time (1, 2, 4, and 8 months), and the use of additives (HCl, sodium azide, benzoic acid, benzyltrimethylammonium chloride, and cetylpyridinium chloride). HPLC with both inductively coupled plasma mass spectrometry and hydride generation atomic fluorescence detection techniques were used for the speciation of arsenic. We found that all five of the arsenic species were stable for up to 2 months when urine samples were stored at 4 and -20 degrees C without any additives. For longer period of storage (4 and 8 months), the stability of arsenic species was dependent on urine matrices. Whereas the arsenic speciation in some urine samples was stable for the entire 8 months at both 4 and -20 degrees C, other urine samples stored under identical conditions showed substantial changes in the concentration of As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid. The use of additives did not improve the stability of arsenic speciation in urine. The addition of 0.1 mol/L HCl (final concentration) to urine samples produced relative changes in inorganic As(III) and As(V) concentrations. Low temperature (4 and -20 degrees C) conditions are suitable for the storage of urine samples for up to 2 months. Untreated samples maintain their concentration of arsenic species, and additives have no particular benefit. Strong acidification is not appropriate for speciation analysis.
NHEXAS PHASE I ARIZONA STUDY--METALS IN URINE ANALYTICAL RESULTS
The Metals in Urine data set contains analytical results for measurements of up to 6 metals in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sample consists of the fir...
Urine sampling and collection system
NASA Technical Reports Server (NTRS)
Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.
1971-01-01
This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.
Blasco, Hélène; Garrigue, Marie-Ange; De Vos, Aymeric; Antar, Catherine; Labarthe, François; Maillot, François; Andres, Christian R; Nadal-Desbarats, Lydie
2010-02-01
NMR spectroscopy of urine samples is able to diagnose many inborn errors of metabolism (IEM). However, urinary metabolites have a poor stability, requiring special care for routine analysis (storage of urine at -20 or -80 degrees C, fast transport). The aim of our study was to investigate the reliability of dried urine filter paper for urine storage and transport and to evaluate the ability of NMR to detect several IEM using this method. Urine samples from five healthy subjects were analyzed by (1)H NMR following different storage conditions (-20 vs 4 degrees C vs dried on filter paper) and at different time points (24 h, 48 h, 96 h, and 7 days). Urine pattern of fresh urine was considered as a reference. We analyzed the conservation of some amino acids and organic acids using Bland and Altman plot with intraclass correlation coefficient determination. Then, we evaluated the use of filter paper to detect four different IEM (methylmalonic and isovaleric acidurias, ornithine transcarbamylase deficiency, and cystinuria). Analysis of urine samples from healthy subjects revealed a high stability of studied molecules (ICC > 0.8) even after 7 days of storage on filter paper. Moreover, an excellent preservation of metabolites specifically accumulated in IEM was observed when analysis of dried urine filter paper was compared to fresh urine (coefficient of variation < 15%). This preliminary study demonstrates that storage of dried urine on filter paper is reliable for (1)H NMR spectroscopy analysis. Preservation of urine molecules over time using that method is convenient for routine clinical practice.
Kordass, Ulrike; Carlson, Regina; Stein, Veronika Maria; Tipold, Andrea
2016-01-08
The purpose of this study was to prove the hypothesis that C-reactive protein (CRP) and nerve growth factor (NGF) may be potential biomarkers for lower urinary tract disorders and may be able to distinguish between micturition dysfunctions of different origin in dogs with spinal cord diseases. NGF- and CRP- concentrations were measured in serum and urine samples using specific ELISA-Kits. Results in urine were standardized by urine-creatinine levels. CRP in serum was detectable in 32/76 and in urine samples in 40/76 patients. NGF could be measured in all serum and in 70/76 urine samples. Urinary CRP concentrations were significantly higher in dogs with micturition dysfunction (p = 0.0009) and in dogs with different neurological diseases (p = 0.0020) compared to the control group. However, comparing dogs with spinal cord disorders with and without associated micturition dysfunction no significant difference could be detected for NGF and CRP values in urine or serum samples. Additionally, levels did not decrease significantly, when measured at the time when the dogs regained the ability to urinate properly (urinary NGF p = 0.7962; urinary CRP p = 0.078). Urine samples with bacteria and/or leukocytes had no significant increase in urinary NGF (p = 0.1112) or CRP (p = 0.0534) concentrations, but higher CRP-levels in urine from dogs with cystitis were found compared to dogs without signs of cystitis. From these data we conclude that neither CRP nor NGF in urine or serum can be considered as reliable biomarkers for micturition disorders in dogs with spinal cord disorders in a clinical setting, but their production might be part of the pathogenesis of such disorders. Significantly higher levels of CRP could be found in the urine of dogs with micturition dysfunctions compared to control dogs. This phenomenon could potentially be explained by unspecific extrahepatic CRP production by smooth muscle cells in the dilated bladder.
Del Coso, Juan; Muñoz, Gloria; Muñoz-Guerra, Jesús
2011-08-01
The aim of this investigation was to determine the use of caffeine by athletes after its removal from the World Anti-Doping Agency list. For this purpose, we measured the caffeine concentration in 20 686 urine samples obtained for doping control from 2004 to 2008. We utilized only urine samples obtained after official national and international competitions. Urine caffeine concentration was determined using alkaline extraction followed by gas chromatography-mass spectrometry. The limit of detection (LOD) was set at 0.1 µg·mL(-1). The percentage of urine samples below the LOD was 26.2%; the remaining 73.8% of the urine samples contained caffeine. Most urine samples (67.3%) had urinary caffeine concentrations below 5 µg·mL(-1). Only 0.6% of urine samples exceeded the former threshold for caffeine doping (12 µg·mL(-1)). Triathlon (3.3 ± 2.2 µg·mL(-1)), cycling (2.6 ± 2.0 µg·mL(-1)), and rowing (1.9 ± 1.4 µg·mL(-1)) were the sports with the highest levels of urine caffeine concentration; gymnastics was the sport with the lowest urine caffeine concentration (0.5 ± 0.4 µg·mL(-1)). Older competitors (>30 y) had higher levels of caffeine in their urine than younger competitors (<20 y; p < 0.05); there were no differences between males and females. In conclusion, 3 out of 4 athletes had consumed caffeine before or during sports competition. Nevertheless, only a small proportion of these competitors (0.6%) had a urine caffeine concentration higher than 12 µg·mL(-1). Endurance sports were the disciplines showing the highest urine caffeine excretion after competition.
Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S
2016-01-01
Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.
Uysal, Deniz; Karadaş, Cennet; Kara, Derya
2017-05-01
A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.
Is a pre-analytical process for urinalysis required?
Petit, Morgane; Beaudeux, Jean-Louis; Majoux, Sandrine; Hennequin, Carole
2017-10-01
For the reliable urinary measurement of calcium, phosphate and uric acid, a pre-analytical process by adding acid or base to urine samples at laboratory is recommended in order to dissolve precipitated solutes. Several studies on different kind of samples and analysers have previously shown that a such pre-analytical treatment is useless. The objective was to study the necessity of pre-analytical treatment of urine on samples collected using the V-Monovette ® (Sarstedt) system and measured on the analyser Architect C16000 (Abbott Diagnostics). Sixty urinary samples of hospitalized patients were selected (n=30 for calcium and phosphate, and n=30 for uric acid). After acidification of urine samples for measurement of calcium and phosphate, and alkalinisation for measurement of uric acid respectively, differences between results before and after the pre-analytical treatment were compared to acceptable limits recommended by the French society of clinical biology (SFBC). No difference in concentration between before and after pre-analytical treatment of urine samples exceeded acceptable limits from SFBC for measurement of calcium and uric acid. For phosphate, only one sample exceeded these acceptable limits, showing a result paradoxically lower after acidification. In conclusion, in agreement with previous study, our results show that acidification or alkalinisation of urine samples from 24 h urines or from urination is not a pre-analytical necessity for measurement of calcium, phosphate and uric acid.
Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review.
Holm, Anne; Aabenhus, Rune
2016-06-08
Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection in primary care. The aim of this study was to determine the accuracy of urine culture from different sampling-techniques in symptomatic non-pregnant women in primary care. A systematic review was conducted by searching Medline and Embase for clinical studies conducted in primary care using a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. We included seven studies investigating urine sampling technique in 1062 symptomatic patients in primary care. Mid-stream-clean-catch had a positive predictive value of 0.79 to 0.95 and a negative predictive value close to 1 compared to sterile techniques. Two randomized controlled trials found no difference in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However, the evidence presented is in-direct and the difference between mid-stream-clean-catch, mid-stream-urine and random samples remains to be investigated in a paired design to verify the present findings.
[Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].
Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo
2016-03-01
The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.
Sycamore, K F; Poorbaugh, V R; Pullin, S S; Ward, C R
2014-07-01
To compare aerobic bacterial culture of urine to cystoscopically obtained mucosal biopsies of the lower urinary tract in dogs. Retrospective review of case records from dogs that had transurethral cystoscopy at a veterinary teaching hospital between 2002 and 2011. Dogs that had culture results from cystocentesis obtained urine and transurethral cystoscopically obtained mucosal samples were included in the study. Pathogens identified were compared between sampling methods. Forty dogs underwent transurethral cystoscopy for lower urinary tract disease on 41 occasions. There was significant (P = 0 · 0003) agreement between urine and mucosal biopsy cultures. Both cultures were negative in 66% and positive in 17% of dogs. There was a 17% disagreement between the sampling methods. Although not statistically significant, more mucosal samples than urine cultures were positive for Escherichia coli. There was a good agreement between pathogen identification from urine and lower urinary tract mucosal cultures. These results do not support the utilisation of transurethral cystoscopy to obtain biopsy samples for culture in dogs with urinary tract infection and positive urine culture. Individual cases with possible chronic urinary tract infection and negative urine culture may benefit from transurethral cystoscopy to obtain biopsies for culture. © 2014 British Small Animal Veterinary Association.
Baixench, M T; Al-Sheikh, M; Paugam, A
2005-01-01
The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.
Detection of human papillomavirus DNA in urine. A review of the literature.
Vorsters, A; Micalessi, I; Bilcke, J; Ieven, M; Bogers, J; Van Damme, P
2012-05-01
The detection of human papillomavirus (HPV) DNA in urine, a specimen easily obtained by a non-invasive self-sampling method, has been the subject of a considerable number of studies. This review provides an overview of 41 published studies; assesses how different methods and settings may contribute to the sometimes contradictory outcomes; and discusses the potential relevance of using urine samples in vaccine trials, disease surveillance, epidemiological studies, and specific settings of cervical cancer screening. Urine sampling, storage conditions, sample preparation, DNA extraction, and DNA amplification may all have an important impact on HPV DNA detection and the form of viral DNA that is detected. Possible trends in HPV DNA prevalence in urine could be inferred from the presence of risk factors or the diagnosis of cervical lesions. HPV DNA detection in urine is feasible and may become a useful tool but necessitates further improvement and standardization.
Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin
2016-03-01
Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN URINE ANALYTICAL RESULTS
The Metals in Urine data set contains analytical results for measurements of up to 7 metals in 86 urine samples over 86 households. Each sample was collected from the primary respondent within each household. The sample consists of the first morning void following the 24-hour d...
Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki
2011-01-01
To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.
Albasan, Hasan; Lulich, Jody P; Osborne, Carl A; Lekcharoensuk, Chalermpol; Ulrich, Lisa K; Carpenter, Kathleen A
2003-01-15
To determine effects of storage temperature and time on pH and specific gravity of and number and size of crystals in urine samples from dogs and cats. Randomized complete block design. 31 dogs and 8 cats. Aliquots of each urine sample were analyzed within 60 minutes of collection or after storage at room or refrigeration temperatures (20 vs 6 degrees C [68 vs 43 degrees F]) for 6 or 24 hours. Crystals formed in samples from 11 of 39 (28%) animals. Calcium oxalate (CaOx) crystals formed in vitro in samples from 1 cat and 8 dogs. Magnesium ammonium phosphate (MAP) crystals formed in vitro in samples from 2 dogs. Compared with aliquots stored at room temperature, refrigeration increased the number and size of crystals that formed in vitro; however, the increase in number and size of MAP crystals in stored urine samples was not significant. Increased storage time and decreased storage temperature were associated with a significant increase in number of CaOx crystals formed. Greater numbers of crystals formed in urine aliquots stored for 24 hours than in aliquots stored for 6 hours. Storage time and temperature did not have a significant effect on pH or specific gravity. Urine samples should be analyzed within 60 minutes of collection to minimize temperature- and time-dependent effects on in vitro crystal formation. Presence of crystals observed in stored samples should be validated by reevaluation of fresh urine.
Aoki, Kimiko; Tanaka, Hiroyuki; Kawahara, Takashi
2018-07-01
The standard method for personal identification and verification of urine samples in doping control is short tandem repeat (STR) analysis using nuclear DNA (nDNA). The DNA concentration of urine is very low and decreases under most conditions used for sample storage; therefore, the amount of DNA from cryopreserved urine samples may be insufficient for STR analysis. We aimed to establish a multiplexed assay for urine mitochondrial DNA typing containing only trace amounts of DNA, particularly for Japanese populations. A multiplexed suspension-array assay using oligo-tagged microspheres (Luminex MagPlex-TAG) was developed to measure C-stretch length in hypervariable region 1 (HV1) and 2 (HV2), five single nucleotide polymorphisms (SNPs), and one polymorphic indel. Based on these SNPs and the indel, the Japanese population can be classified into five major haplogroups (D4, B, M7a, A, D5). The assay was applied to DNA samples from urine cryopreserved for 1 - 1.5 years (n = 63) and fresh blood (n = 150). The assay with blood DNA enabled Japanese subjects to be categorized into 62 types, exhibiting a discriminatory power of 0.960. The detection limit for cryopreserved urine was 0.005 ng of nDNA. Profiling of blood and urine pairs revealed that 5 of 63 pairs showed different C-stretch patterns in HV1 or HV2. The assay described here yields valuable information in terms of the verification of urine sample sources employing only trace amounts of recovered DNA. However, blood cannot be used as a reference sample.
Stability studies of amphetamine and ephedrine derivatives in urine.
Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R
2006-10-20
Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.
Albumin adsorption onto surfaces of urine collection and analysis containers☆
Robinson, Mary K.; Caudill, Samuel P.; Koch, David D.; Ritchie, James; Hortin, Glen; Eckfeldt, John H.; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W. Greg
2017-01-01
Background Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods We added 125I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results Adsorption of urine albumin (UA) at 5–6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH 8 than pH 5 but only 3 cases had p <0.05. Adsorption from 11 unaltered urine samples with albumin 5–333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2 l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2–28%) was larger than that from urine. Conclusions Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. PMID:24513540
Albumin adsorption onto surfaces of urine collection and analysis containers.
Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg
2014-04-20
Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.
Solid phase extraction of 2,4-D from human urine.
Thompson, T S; Treble, R G
1996-10-01
A method for determining urinary concentrations of 2,4-D in samples collected from non-occupationally, environmentally exposed individuals was developed. The 2,4-D was extracted from fortified human urine samples using octadecylsilane solid phase extraction cartridges. The average percent recovery for urine samples spiked at 2 and 20 ng/mL was 100% and 93%, respectively. The method detection limit was estimated to be 0.75 ng of 2,4-D per mL of urine based on a 10 mL sample size. The potential use of 2,4-dichlorophenylacetic acid as a surrogate standard was also investigated.
Li, Wenkui; Luo, Suyi; Smith, Harold T; Tse, Francis L S
2010-02-15
Analyte loss due to non-specific binding, especially container surface adsorption, is not uncommon in the quantitative analysis of urine samples. In developing a sensitive LC-MS/MS method for the determination of a drug candidate, BAF312, in human urine, a simple procedure was outlined for identification, confirmation and prevention of analyte non-specific binding to a container surface and to recover the 'non-specific loss' of an analyte, if no transfer has occurred to the original urine samples. Non-specific binding or container surface adsorption can be quickly identified by using freshly spiked urine calibration standards and pre-pooled QC samples during a LC-MS/MS feasibility run. The resulting low recovery of an analyte in urine samples can be prevented through the use of additives, such as the non-ionic surfactant Tween-80, CHAPS and others, to the container prior to urine sample collection. If the urine samples have not been transferred from the bulk container, the 'non-specific binding' of an analyte to the container surface can be reversed by the addition of a specified amount of CHAPS, Tween-80 or bovine serum albumin, followed by appropriate mixing. Among the above agents, Tween-80 is the most cost-effective. beta-cyclodextrin may be suitable in stabilizing the analyte of interest in urine via pre-treating the matrix with the agent. However, post-addition of beta-cyclodextrin to untreated urine samples does not recover the 'lost' analyte due to non-specific binding or container surface adsorption. In the case of BAF312, a dynamic range of 0.0200-20.0 ng/ml in human urine was validated with an overall accuracy and precision for QC sample results ranging from -3.2 to 5.1% (bias) and 3.9 to 10.2% (CV), respectively. Pre- and post-addition of 0.5% (v/v) Tween-80 to the container provided excellent overall analyte recovery and minimal MS signal suppression when a liquid-liquid extraction in combination with an isocratic LC separation was employed. The compound was stable in 0.5% Tween-80 treated human urine QC samples for at least 24 h at room temperature, after three freeze/thaw cycles with storage at < or =-60 degrees C and for at least 3 months when stored at < or =-60 degrees C. The current work could serve as a simple example in trouble shooting non-specific binding or container surface adsorption in quantitative analysis of urine samples. Copyright 2010. Published by Elsevier B.V.
Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed
2014-10-31
In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Gambelunghe, Cristiana; Sommavilla, Marco; Rossi, Ruggero
2002-12-01
The concentrations of nandrolone metabolites, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) were analysed in urine samples of professional athletes doing intense physical activity and sedentary subjects to verify if there was endogenous production of nandrolone and if there was any link between physical effort and the urinary metabolites of the steroid. We collected 18 urine samples from professional footballers age range 20-30 years, all from the same team, and 18 urine samples from males not doing any physical activity, age range 20-30 years. Neither group used nandrolone. Qualitative and quantitative analyses of urinary nandrolone metabolites were carried out by GC/MS followed by GC/MS/MS to confirm positive samples. This technique has been demonstrated to be an excellent analytical approach for the determination of anabolic steroids at very low detection limits in complex matrices such as urine. In five urine samples from professional footballers traces of 19-NA were detected. No trace of 19-NA was found in the group of sedentary subjects and no trace of 19-NE was found in any urine sample. The absence of nandrolone metabolites in sedentary subjects supports the hypothesis that the presence of 19-NA and 19-NE could be linked to physical effort even though the origin is not yet clear. Copyright 2002 John Wiley & Sons, Ltd.
Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo
2018-01-01
This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
51Cr-EDTA absorption blood test: an easy method for assessing small intestinal permeability in dogs.
Frias, Rafael; Sankari, Satu; Westermarck, Elias
2004-01-01
The 51Cr-EDTA test is a valuable clinical tool for screening intestinal diseases in dogs. The test is performed by calculating the percentage of recovery from urine of a PO-ingested dose of 51Cr-EDTA after 6 or 24 hours. Careful urine collection is a practical limitation of this test in dogs, and our goal was to develop a simpler test that measures 51Cr-EDTA in blood. A 51Cr-EDTA absorption test was simultaneously performed on urine and serum 43 times in healthy Beagle Dogs. Timed blood samples were withdrawn, and urine was collected during a 6-hour period. Percentages of the ingested dose were then calculated in urine and serum. The mean +/- standard deviation (range) percentage in urine after 6 hours was 14.07 +/- 8.72% (3.81-34.18%), whereas results in serum from samples taken at 2, 3, 4, 5, and 6 hours were 0.49 +/- 0.45% (0.02-2.13%), 0.75 +/- 0.52% (0.03-1.89%), 0.82 +/- 0.57% (0.13-2.21%), 0.70 +/- 0.53% (0.12-1.99%), and 0.47 +/- 0.44% (0.11-1.79%), respectively. The results for blood specimens showed good concordance with those for urine, especially for the samples taken at 4 hours (r = 0.89). Moreover, the correlation between urine and blood was better when the sum of the percentages of the recovered analyte from various blood samples was compared with urine. The correlation coefficient when summing 4 blood samples was excellent (r = 0.97) and remained excellent when summing only 2 blood samples taken at 3 and 5 hours (r = 0.95) or at 3 and 4 hours (r = 0.94). We conclude that a serum 51Cr-EDTA test determined by summing successive blood samples provides an easier means of estimating small intestinal permeability in dogs and gives results comparable to those of the 6-hour urine test.
Wozniak, Barbara; Matraszek-Zuchowska, Iwona; Witek, Sebastian; Zmudzki, Jan; Posyniak, Andrzej
2018-01-15
Thyreostatic compounds, such as thiouracil, are orally active drugs that can be used to increase the weight of cattle before slaughter. Due to potentially teratogenic and carcinogenic effects of their residues on public health, the use of thyreostats in animal production has been banned in the European Union since 1981. Systematic detection of low concentrations of thiouracil in the urine of livestock in many countries is believed to be of endogenous origin due to the use of Brassicaceae plants in the animal diet. Therefore, the purpose of the study was to determine the effects of diets rich in rapeseed meal on formation of thiouracil in urine and milk of dairy cows. For two weeks three cows were subjected to a diet supplemented with rapeseed at 30%, compared to the control cattle diet which contained up to 11% rapeseed. During the experiment, samples of urine and milk were collected and analysed by LC-MS/MS. The increase and decrease of thiouracil concentration in urine samples in different animals was individual and cyclic. The highest concentration of natural thiouracil determined in urine was 3.61 μg l -1 . It has been found that endogenous thiouracil exists in two tautomeric forms. A few days of storage of frozen urine samples affected the stability of natural thiouracil, whereas an acidic medium improved the stability of the compound and its isomer, which remained stable even after two months of storage at temperatures below -18°C. Due to the instability of thiouracil, urine samples upon sampling should be delivered to the laboratory as soon as possible or properly preserved. In milk samples, thiouracil was not found above the decision limit of the applied method of 0.63 μg l -1 . Preliminary studies have shown that faecal examination for banned thiouracil can be a complementary test for urine samples, and may be helpful in determining the origin of the compound present in urine.
Appannanavar, Suma B; Biswal, Manisha; Rajkumari, Nonika; Mohan, Balvinder; Taneja, Neelam
2013-01-01
Urine culture is a gold standard in the diagnosis of urinary tract infection. Clean catch midstream urine collection and prompt transportation is essential for appropriate diagnosis. Improper collection and delay in transportation leads to diagnostic dilemma. In developing countries, higher ambient temperatures further complicate the scenario. Here, we have evaluated the role of boric acid as a preservative for urine samples prior to culture in female patients attending outpatient department at our center. Consecutive 104 urine samples were cultured simultaneously in plain uricol (Control-C) and boric acid containing tubes from Becton Dickinson urine culture kit (Boric acid group-BA). In the real-time evaluation, we found that in almost 57% (59/104) of the urine samples tested, it was more effective in maintaining the number of the organisms as compared to samples in the container without any preservative. Our in vitro study of simulated urine cultures revealed that urine samples could be kept up to 12 h before culture in the preservative without any inhibitory effect of boric acid. Though the use of boric acid kit may marginally increase the initial cost but has indirect effects like preventing delays in treatment and avoidance of false prescription of antibiotics. If the man-hours spent on repeat investigations are also taken into consideration, then the economic cost borne by the laboratory would also decrease manifold with the use of these containers.
Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.
Broeren, Maarten A C; Bahçeci, Semiha; Vader, Huib L; Arents, Niek L A
2011-03-01
The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated the detection of bacteria and leukocytes by a new urine analyzer, the UF-1000i, to identify negative urine samples that can be excluded from urine culture. In total, 1,577 urine samples were analyzed and compared to urine culture. Urine culture showed growth of ≥10(3) CFU/ml in 939 samples (60%). Receiver operating characteristics (ROC) curves and ROC decision plots were been prepared at three different gold standard definitions of a negative urine culture: no growth, growth of bacteria at <10(4) CFU/ml, and growth of bacteria at <10(5) CFU/ml. Also, the reduction in urine cultures and the percentage of false negatives were calculated. At the most stringent gold standard definition of no growth, a chosen sensitivity of 95% resulted in a cutoff value of 26 bacteria/μl, a specificity of 43% and a reduction in urine cultures of only 20%, of which 14% were false negatives. However, at a gold standard definition of <10(5) CFU/ml and a sensitivity of 95%, the UF-1000i cutoff value was 230 bacteria/μl, the specificity was 80%, and the reduction in urine cultures was 52%, of which 0.3% were false negatives. The applicability of the UF-1000i to screen for negative urine samples strongly depends on population characteristics and the definition of a negative urine culture. In our setting, however, the low workload savings and the high percentage of false-negative results do not warrant the UF-1000i to be used as a screening analyzer.
Kogut, Katherine; Eisen, Ellen A.; Jewell, Nicholas P.; Quirós-Alcalá, Lesliam; Castorina, Rosemary; Chevrier, Jonathan; Holland, Nina T.; Barr, Dana Boyd; Kavanagh-Baird, Geri; Eskenazi, Brenda
2012-01-01
Background: Dialkyl phosphate (DAP) metabolites in spot urine samples are frequently used to characterize children’s exposures to organophosphorous (OP) pesticides. However, variable exposure and short biological half-lives of OP pesticides could result in highly variable measurements, leading to exposure misclassification. Objective: We examined within- and between-child variability in DAP metabolites in urine samples collected during 1 week. Methods: We collected spot urine samples over 7 consecutive days from 25 children (3–6 years of age). On two of the days, we collected 24-hr voids. We assessed the reproducibility of urinary DAP metabolite concentrations and evaluated the sensitivity and specificity of spot urine samples as predictors of high (top 20%) or elevated (top 40%) weekly average DAP metabolite concentrations. Results: Within-child variance exceeded between-child variance by a factor of two to eight, depending on metabolite grouping. Although total DAP concentrations in single spot urine samples were moderately to strongly associated with concentrations in same-day 24-hr samples (r ≈ 0.6–0.8, p < 0.01), concentrations in spot samples collected > 1 day apart and in 24-hr samples collected 3 days apart were weakly correlated (r ≈ –0.21 to 0.38). Single spot samples predicted high (top 20%) and elevated (top 40%) full-week average total DAP excretion with only moderate sensitivity (≈ 0.52 and ≈ 0.67, respectively) but relatively high specificity (≈ 0.88 and ≈ 0.78, respectively). Conclusions: The high variability we observed in children’s DAP metabolite concentrations suggests that single-day urine samples provide only a brief snapshot of exposure. Sensitivity analyses suggest that classification of cumulative OP exposure based on spot samples is prone to type 2 classification errors. PMID:23052012
COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES
To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...
Mengual, Lourdes; Burset, Moisès; Ribal, María José; Ars, Elisabet; Marín-Aguilera, Mercedes; Fernández, Manuel; Ingelmo-Torres, Mercedes; Villavicencio, Humberto; Alcaraz, Antonio
2010-05-01
To develop an accurate and noninvasive method for bladder cancer diagnosis and prediction of disease aggressiveness based on the gene expression patterns of urine samples. Gene expression patterns of 341 urine samples from bladder urothelial cell carcinoma (UCC) patients and 235 controls were analyzed via TaqMan Arrays. In a first phase of the study, three consecutive gene selection steps were done to identify a gene set expression signature to detect and stratify UCC in urine. Subsequently, those genes more informative for UCC diagnosis and prediction of tumor aggressiveness were combined to obtain a classification system of bladder cancer samples. In a second phase, the obtained gene set signature was evaluated in a routine clinical scenario analyzing only voided urine samples. We have identified a 12+2 gene expression signature for UCC diagnosis and prediction of tumor aggressiveness on urine samples. Overall, this gene set panel had 98% sensitivity (SN) and 99% specificity (SP) in discriminating between UCC and control samples and 79% SN and 92% SP in predicting tumor aggressiveness. The translation of the model to the clinically applicable format corroborates that the 12+2 gene set panel described maintains a high accuracy for UCC diagnosis (SN = 89% and SP = 95%) and tumor aggressiveness prediction (SN = 79% and SP = 91%) in voided urine samples. The 12+2 gene expression signature described in urine is able to identify patients suffering from UCC and predict tumor aggressiveness. We show that a panel of molecular markers may improve the schedule for diagnosis and follow-up in UCC patients. Copyright 2010 AACR.
Chuang, Jane C; Emon, Jeanette M Van; Durnford, Joyce; Thomas, Kent
2005-09-15
An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within +/-20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within +/-20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30ng/mL by ELISA and 0.2ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10mL of urine converted into 1mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.
Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S
2015-04-01
This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.
Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.
2014-01-01
This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921
A novel way to monitor urine concentration: fluorescent concentration matrices.
Dubayova, Katarina; Luckova, Iveta; Sabo, Jan; Karabinos, Anton
2015-01-01
The amount of water found in urine is important diagnostic information; nevertheless it is not yet directly determined. Indirectly, the water content in urine is expressed by its density (specific gravity). However, without the diuresis value it is not possible to determine whether the increase in density of urine is due to a decrease in water secretion or an increase in the concentration of secreted substances. This problem can be solved by the use of fluorescent concentration 3D-matrices which characterise urine concentration through the pφ (or -logφ) value of the first fluorescence centre. The urine fluorescent concentration 3D-matrix was created by the alignment of the synchronous spectra of the dilution series of urine starting from undiluted (pφ = 0) to 1000-fold diluted urine (pφ = 3). Using the fluorescence concentration 3D-matrix analysis of the urine samples from healthy individuals, a reference range was established for the value pφ, determining the normal, concentrated or diluted type of urine. The diagnostic potential of this approach was tested on urine samples from two patients with a chronic glomerulonephritis. The pφ value of the urine fluorescence concentration 3D-matrix analysis determines whether the urine sample falls within the normal, concentrated or diluted type of urine. This parameter can be directly utilised in sportsmen's hydration state monitoring, as well as in the diagnosis and treatment of serious diseases. An important advantage of this novel diagnostic approach is that a 12/24 h urine collection is not required, which predetermines it for use especially within paediatrics.
Corstjens, Paul L A M; Nyakundi, Ruth K; de Dood, Claudia J; Kariuki, Thomas M; Ochola, Elizabeth A; Karanja, Diana M S; Mwinzi, Pauline N M; van Dam, Govert J
2015-04-22
Accurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction. Centrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test. Implementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay. Larger sample input increased Sn of the UCAA assay to a level indicating 'true' infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.
The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis
Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio
2015-01-01
Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas. PMID:26230990
Daily sodium and potassium excretion can be estimated by scheduled spot urine collections.
Doenyas-Barak, Keren; Beberashvili, Ilia; Bar-Chaim, Adina; Averbukh, Zhan; Vogel, Ofir; Efrati, Shai
2015-01-01
The evaluation of sodium and potassium intake is part of the optimal management of hypertension, metabolic syndrome, renal stones, and other conditions. To date, no convenient method for its evaluation exists, as the gold standard method of 24-hour urine collection is cumbersome and often incorrectly performed, and methods that use spot or shorter collections are not accurate enough to replace the gold standard. The aim of this study was to evaluate the correlation and agreement between a new method that uses multiple-scheduled spot urine collection and the gold standard method of 24-hour urine collection. The urine sodium or potassium to creatinine ratios were determined for four scheduled spot urine samples. The mean ratios of the four spot samples and the ratios of each of the single spot samples were corrected for estimated creatinine excretion and compared to the gold standard. A significant linear correlation was demonstrated between the 24-hour urinary solute excretions and estimated excretion evaluated by any of the scheduled spot urine samples. The correlation of the mean of the four spots was better than for any of the single spots. Bland-Altman plots showed that the differences between these measurements were within the limits of agreement. Four scheduled spot urine samples can be used as a convenient method for estimation of 24-hour sodium or potassium excretion. © 2015 S. Karger AG, Basel.
Estimating population salt intake in India using spot urine samples.
Petersen, Kristina S; Johnson, Claire; Mohan, Sailesh; Rogers, Kris; Shivashankar, Roopa; Thout, Sudhir Raj; Gupta, Priti; He, Feng J; MacGregor, Graham A; Webster, Jacqui; Santos, Joseph Alvin; Krishnan, Anand; Maulik, Pallab K; Reddy, K Srinath; Gupta, Ruby; Prabhakaran, Dorairaj; Neal, Bruce
2017-11-01
To compare estimates of mean population salt intake in North and South India derived from spot urine samples versus 24-h urine collections. In a cross-sectional survey, participants were sampled from slum, urban and rural communities in North and in South India. Participants provided 24-h urine collections, and random morning spot urine samples. Salt intake was estimated from the spot urine samples using a series of established estimating equations. Salt intake data from the 24-h urine collections and spot urine equations were weighted to provide estimates of salt intake for Delhi and Haryana, and Andhra Pradesh. A total of 957 individuals provided a complete 24-h urine collection and a spot urine sample. Weighted mean salt intake based on the 24-h urine collection, was 8.59 (95% confidence interval 7.73-9.45) and 9.46 g/day (8.95-9.96) in Delhi and Haryana, and Andhra Pradesh, respectively. Corresponding estimates based on the Tanaka equation [9.04 (8.63-9.45) and 9.79 g/day (9.62-9.96) for Delhi and Haryana, and Andhra Pradesh, respectively], the Mage equation [8.80 (7.67-9.94) and 10.19 g/day (95% CI 9.59-10.79)], the INTERSALT equation [7.99 (7.61-8.37) and 8.64 g/day (8.04-9.23)] and the INTERSALT equation with potassium [8.13 (7.74-8.52) and 8.81 g/day (8.16-9.46)] were all within 1 g/day of the estimate based upon 24-h collections. For the Toft equation, estimates were 1-2 g/day higher [9.94 (9.24-10.64) and 10.69 g/day (9.44-11.93)] and for the Kawasaki equation they were 3-4 g/day higher [12.14 (11.30-12.97) and 13.64 g/day (13.15-14.12)]. In urban and rural areas in North and South India, most spot urine-based equations provided reasonable estimates of mean population salt intake. Equations that did not provide good estimates may have failed because specimen collection was not aligned with the original method.
EURADOS intercomparison on emergency radiobioassay.
Li, Chunsheng; Battisti, Paolo; Berard, Philippe; Cazoulat, Alain; Cuellar, Antonio; Cruz-Suarez, Rodolfo; Dai, Xiongxin; Giardina, Isabella; Hammond, Derek; Hernandez, Carolina; Kiser, Stephen; Ko, Raymond; Kramer-Tremblay, Sheila; Lecompte, Yannick; Navarro, Eva; Navas, Cristina; Sadi, Baki; Sierra, Inmaculada; Verrezen, Freddy; Lopez, Maria A
2015-12-01
Nine laboratories participated in an intercomparison exercise organised by the European Radiation Dosimetry Group (EURADOS) for emergency radiobioassay involving four high-risk radionuclides ((239)Pu, (241)Am, (90)Sr and (226)Ra). Diverse methods of analysis were used by the participating laboratories for the in vitro determination of each of the four radionuclides in urine samples. Almost all the methods used are sensitive enough to meet the requirements for emergency radiobioassay derived for this project in reference to the Clinical Decision Guide introduced by the NCRP. Results from most of the methods meet the requirements of ISO 28218 on accuracy in terms of relative bias and relative precision. However, some technical gaps have been identified. For example, some laboratories do not have the ability to assay samples containing (226)Ra, and sample turnaround time would be expected to be much shorter than that reported by many laboratories, as timely results for internal contamination and early decisions on medical intervention are highly desired. Participating laboratories are expected to learn from each other on the methods used to improve the interoperability among these laboratories. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Simple DNA extraction of urine samples: Effects of storage temperature and storage time.
Ng, Huey Hian; Ang, Hwee Chen; Hoe, See Ying; Lim, Mae-Lynn; Tai, Hua Eng; Soh, Richard Choon Hock; Syn, Christopher Kiu-Choong
2018-06-01
Urine samples are commonly analysed in cases with suspected illicit drug consumption. In events of alleged sample mishandling, urine sample source identification may be necessary. A simple DNA extraction procedure suitable for STR typing of urine samples was established on the Promega Maxwell ® 16 paramagnetic silica bead platform. A small sample volume of 1.7mL was used. Samples were stored at room temperature, 4°C and -20°C for 100days to investigate the influence of storage temperature and time on extracted DNA quantity and success rate of STR typing. Samples stored at room temperature exhibited a faster decline in DNA yield with time and lower typing success rates as compared to those at 4°C and -20°C. This trend can likely be attributed to DNA degradation. In conclusion, this study presents a quick and effective DNA extraction protocol from a small urine volume stored for up to 100days at 4°C and -20°C. Copyright © 2018 Elsevier B.V. All rights reserved.
Joshi, Madhuri S; Bhalla, Shilpa; Kalrao, Vijay R; Dhongade, Ramchandra K; Chitambar, Shobha D
2014-04-01
The use of saliva and urine as an alternative to serum samples for detection of anti-hepatitis A virus (HAV) IgM antibodies has been documented. However, these samples remain underreported or unexplored for shedding of HAV. To address this issue, paired serum, stool, saliva, and urine samples collected from hepatitis A patients were screened by reverse transcription polymerase chain reaction for detection of HAV RNA. HAV RNA was detected in 67.6% (44/65), 52.3% (34/65), 8.7% (5/57), and 12.3% (8/65) of the serum, stool, saliva, and urine samples, respectively. Phylogenetic analysis of nucleotide sequences obtained for partial RNA polymerase region grouped HAV strains from all of the clinical samples of the study in subgenotype IIIA. Low frequency of HAV nucleic acid in saliva and urine samples indicates limited utility of these samples in genomic studies on HAV but suggests its potential for transmission and infection of hepatitis A. Copyright © 2014 Elsevier Inc. All rights reserved.
A magnetic bead-based method for concentrating DNA from human urine for downstream detection.
Bordelon, Hali; Russ, Patricia K; Wright, David W; Haselton, Frederick R
2013-01-01
Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3) to 5×10(8) copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6), 14×10(6), and 8×10(6) copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.
A Magnetic Bead-Based Method for Concentrating DNA from Human Urine for Downstream Detection
Bordelon, Hali; Russ, Patricia K.; Wright, David W.; Haselton, Frederick R.
2013-01-01
Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×103 to 5×108 copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×106, 14×106, and 8×106 copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR. PMID:23861895
Jet Fuel Exposure and Neurological Health in Military Personnel
2011-07-01
and dermal samples E Absorbed Dose measure: Exhaled breath, urine , blood F Lifestyle factors (smoking), use of protective equipment (gloves...toluene, ethylbenzene, xylene, and naphthalene. To assess personal absorbed dose levels to JP8 components, exhaled breath and urine samples were...the following primary analytes of interest were measured: benzene, toluene, ethylbenzene, xylene, and naphthalene. Pre- and post- shift urine samples
NASA Technical Reports Server (NTRS)
Bush, V. N.
1973-01-01
A method for accurately determining urinary tract infections in man is introduced. The method is based on adenosine triphosphate (ATP) concentration in urine samples after removing nonbacterial ATP. Adenosine triphosphate concentration is measured from the bioluminescent reaction of luciferase when mixed with ATP. An examination was also made of the effectiveness of rupturing agents on monkey kidney cells Candia albicans, a Rhodotorula species, and a Streptomyces species in determining whether these cells could contribute ATP to the bacterial ATP value of a urine sample.
Development of an immunochromatographic assay for the β-adrenergic agonist feed additive zilpaterol.
Shelver, Weilin L; Smith, David J
2018-06-06
Zilpaterol is a β-adrenergic agonist feed additive approved in the United States to increase weight gain and improve feed efficiency of cattle. A zilpaterol immunochromatographic assay was developed as an economical and user-friendly rapid detection method for zilpaterol and validated using urine and tissue samples derived from animal studies. The assay sensitivity was 1.7-23.2 ng g -1 or mL -1 across a variety of feed and animal matrices and did not cross-react with clenbuterol or ractopamine. No sample pre-treatment of cattle and sheep urine was needed, but horse urine and feed required dilution; skeletal muscle required solvent extraction prior to testing. Of 32 incurred sheep urine samples tested, zilpaterol content was correctly identified in all but 2 samples. Horse urine containing >10 ng mL -1 of incurred zilpaterol residue (n = 48) was correctly identified as zilpaterol positive. The assay correctly identified 0-day withdrawal sheep muscle samples as zilpaterol positive and the control and longer withdrawal day sheep muscle samples as negative. Zilpaterol was demonstrated to be stable in horse urine when stored at -20°C for 7 years.
Barcenas, Mariana; Suhr, Teryn R; Scott, C Ronald; Turecek, Frantisek; Gelb, Michael H
2014-06-10
Treatments are being developed for metachromatic leukodystrophy (MLD), suggesting the need for eventual newborn screening. Previous studies have shown that sulfatide molecular species are increased in the urine of MLD patients compared to samples from non-MLD individuals, but there is no data using dried blood spots (DBS), the most common sample available for newborn screening laboratories. We used ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) to quantify sulfatides in DBS and dried urine spots from 14 MLD patients and 50 non-MLD individuals. Several sulfatide molecular species were increased in dried urine samples from all MLD samples compared to non-MLD samples. Sulfatides, especially low molecular species, were increased in DBS from MLD patients, but the sulfatide levels were relatively low. There was good separation in sulfatide levels between MLD and non-MLD samples when dried urine spots were used, but not with DBS, because DBS from non-MLD individuals have measurable levels of sulfatides. Sulfatide accumulation studies in urine, but not in DBS, emerges as the method of choice if newborn screening is to be proposed for MLD. Copyright © 2013 Elsevier B.V. All rights reserved.
USE OF DISPOSABLE DIAPERS TO COLLECT URINE IN EXPOSURE STUDIES
Large studies of children's health as it relates to exposures to chemicals in the environment often require measurements of biomarkers of chemical exposures or effects in urine samples. But collection of urine samples from infants and toddlers is difficult. For large exposure s...
The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative
NASA Technical Reports Server (NTRS)
Nillen, Jeannie L.; Smith, Scott M.
2003-01-01
A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.
Urine sugar test; Urine glucose test; Glucosuria test; Glycosuria test ... After you provide a urine sample, it is tested right away. The health care provider uses a dipstick made with a color-sensitive pad. The ...
24-hour urinary aldosterone excretion test
Aldosterone - urine; Addison disease - urine aldosterone; Cirrhosis - serum aldosterone ... A 24-hour urine sample is needed. You will need to collect your urine over 24 hours . Your health care provider will tell ...
Temporal variability of urinary cadmium in spot urine samples and first morning voids.
Vacchi-Suzzi, Caterina; Porucznik, Christina A; Cox, Kyley J; Zhao, Yuan; Ahn, Hongshik; Harrington, James M; Levine, Keith E; Demple, Bruce; Marsit, Carmen J; Gonzalez, Adam; Luft, Benjamin; Meliker, Jaymie R
2017-05-01
Cadmium is a carcinogenic heavy metal. Urinary levels of cadmium are considered to be an indicator of long-term body burden, as cadmium accumulates in the kidneys and has a half-life of at least 10 years. However, the temporal stability of the biomarker in urine samples from a non-occupationally exposed population has not been rigorously established. We used repeated measurements of urinary cadmium (U-Cd) in spot urine samples and first morning voids from two separate cohorts, to assess the temporal stability of the samples. Urine samples from two cohorts including individuals of both sexes were measured for cadmium and creatinine. The first cohort (Home Observation of Perinatal Exposure (HOPE)) consisted of 21 never-smokers, who provided four first morning urine samples 2-5 days apart, and one additional sample roughly 1 month later. The second cohort (World Trade Center-Health Program (WTC-HP)) consisted of 78 individuals, including 52 never-smokers, 22 former smokers and 4 current smokers, who provided 2 spot urine samples 6 months apart, on average. Intra-class correlation was computed for groups of replicates from each individual to assess temporal variability. The median creatinine-adjusted U-Cd level (0.19 and 0.21 μg/g in the HOPE and WTC-HP, respectively) was similar to levels recorded in the United States by the National Health and Nutrition Examination Survey. The intra-class correlation (ICC) was high (0.76 and 0.78 for HOPE and WTC-HP, respectively) and similar between cohorts, irrespective of whether samples were collected days or months apart. Both single spot or first morning urine cadmium samples show good to excellent reproducibility in low-exposure populations.
Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J
2016-06-01
The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Lead Quantification in Urine Samples of Athletes by Coupling DLLME with UV-Vis Spectrophotometry.
Faraji, Hakim; Helalizadeh, Masoumeh
2017-04-01
Urine lead level is one of the most employed measures of lead exposure and risk. The urine samples used in this study were obtained from ten healthy male cyclists. Dispersive liquid-liquid microextraction combined with ultraviolet and visible spectrophotometry was utilized for preconcentration, extraction, and determination of lead in urine samples. Optimization of the independent variables was carried out based on chemometric methods in three steps. According to the screening and optimization study, 133 μL of CCl 4 (extracting solvent), 1.34 mL ethanol (dispersing solvent), pH 2.0, 0.00 % of salt, and 0.1 % O,O-diethyl dithiophosphoric (chelating agent) were used as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R 2 was 0.9991, and linearity range was 0.01-100 μg L -1 . Precision was evaluated in terms of repeatability and intermediate precision, with relative standard deviations being <9.1 and <15.3 %, respectively. The accuracy was estimated using urine samples of cyclists as real samples and it was confirmed. The relative error of ≤5 % was considered significant in the method specificity study. The lead concentration mean for the cyclists was 3.79 μg L -1 in urine samples. As a result, the proposed method is a robust technique to quantify lead concentrations higher than 11.6 ng L -1 in urine samples.
Rapid Diagnosis of Tuberculosis from Analysis of Urine Volatile Organic Compounds
Lim, Sung H.; Martino, Raymond; Anikst, Victoria; Xu, Zeyu; Mix, Samantha; Benjamin, Robert; Schub, Herbert; Eiden, Michael; Rhodes, Paul A.; Banaei, Niaz
2017-01-01
The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different urine test conditions. Basified testing condition yielded the best accuracy with 85.5% sensitivity and 79.5% specificity. The CSA urine assay offers desired features needed for tuberculosis diagnosis in endemic settings. PMID:29057329
Li, Jingguang; Guo, Feifei; Wang, Yuxin; Zhang, Jialing; Zhong, Yuxin; Zhao, Yunfeng; Wu, Yongning
2013-03-01
Because of the disadvantages of invasive sampling, it is desirable to explore non-invasive matrices for human biomonitoring of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). The aim of this study was to evaluate the application of nail, hair and urine for human biomonitoring of PFOS and PFOA. The concentrations of PFOS and PFOA in matched nail, hair, urine and serum samples collected from 64 donors were measured. The chemicals of interest were detected with high detection frequency in these matrices (90%-100%) except for PFOA in urine samples (56%). Generally, the gender influences on the levels of PFOS and PFOA in these non-invasive matrices were in agreement with that in serum. For PFOS, the coefficients of Spearman correlation between serum samples and nail, hair and urine samples were 0.786 (p<0.001), 0.545 (p<0.001) and 0.302 (p<0.05), respectively. For PFOA, the correlation was only observed between nail samples and serum samples with a correlation coefficient of 0.299 (p<0.05). The results suggested that nail has more potential than hair and urine to be applied in human biomonitoring for PFOS and PFOA in general populations. Copyright © 2013 Elsevier Ltd. All rights reserved.
Erickson, D.A.; Gingerich, W.H.
1986-01-01
Renal function was evaluated in adult rainbow trout (Salmo gairdneri) dosed i.a. with rotenone at 225 and 275 μg/kg. The chemical composition of urine samples and urine flow rates collected over a 5-h pretreatment period were compared with hourly urine samples collected over a 5-h posttreatment period. Significant increases in osmolality and in concentrations of sodium, potassium, chloride, glucose, and total protein were observed in the urine of treated fish. Urine solute concentrations reached maximum values within 1 to 3 h after treatment and decreased thereafter, indicating that the effects were reversible. Concentrations of sodium and chloride were highly correlated in 2-h posttreatment urine samples at the low (r = 0.922) and high (r = 0.981) rotenone treatments. Urine flow rates were reduced in trout at each dose of rotenone but the decrease in volume of urine voided was not dose-dependent. In a separate study, [14C]polyethylene glycol was used as a filtration marker to determine the effect of rotenone treatment (225 &mu:g/kg) on urine flow rate, glomerular filtration rate, and renal water reabsorption. We showed that posttreatment urine flow rates were reduced partly by reduced glomerular filtration and partly by increased water reabsorption. Transient increases in plasma osmolality and hematocrit also were observed 0.5 h after rotenone treatment.
NHEXAS PHASE I MARYLAND STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS
The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 9 pesticides in 345 urine samples over 79 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning ...
NHEXAS PHASE I ARIZONA STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS
The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 4 pesticide metabolites in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. ...
Coorevits, L; Heytens, S; Boelens, J; Claeys, G
2017-04-01
The workup and interpretation of urine cultures is not always clear-cut, especially for midstream samples contaminated with commensals. Standard urine culture (SUC) protocols are designed in favor of growth of uropathogens at the expense of commensals. In selected clinical situations, however, it is essential to trace fastidious or new uropathogens by expanding the urine culture conditions (EUC). The aim of our study was to map the microflora in midstream urine specimens from healthy controls by means of EUC, in view of the interpretation of bacterial culture results in symptomatic patients. Midstream urine specimens from 101 healthy controls (86 females and 15 males) were examined using both SUC and EUC. Whilst 73 % of samples examined by SUC showed no growth at 10 3 colony-forming units (CFU)/mL, 91 % of samples examined by EUC grew bacterial species in large numbers (≥10 4 CFU/mL). Asymptomatic bacteriuria, as defined by the European guidelines for urinalysis, was detected in six samples with both protocols. EUC revealed 98 different species, mostly Lactobacillus, Staphylococcus, Streptococcus, and Corynebacterium. None of the samples grew Staphylococcus saprophyticus, Corynebacterium urealyticum, or Aerococcus urinae. Samples from females contained higher bacterial loads and showed higher bacterial diversity compared to males. Midstream urine of healthy controls contains large communities of living bacteria that comprise a resident microflora, only revealed by EUC. Hence, the use of EUC instead of SUC in a routine setting would result in more sensitive but less specific results, requiring critical interpretation. In our view, EUC should be reserved for limited indications.
Wilhelm, M; Ohnesorge, F K
1990-01-01
The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.
Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo
2014-01-01
Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.
Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo
2014-01-01
Background Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. Methods We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Results Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. Conclusions We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria. PMID:24466168
Tracer techniques for urine volume determination and urine collection and sampling back-up system
NASA Technical Reports Server (NTRS)
Ramirez, R. V.
1971-01-01
The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.
Tivapasi, Musavenga T; Hodges, Joanne; Byrne, Barbara A; Christopher, Mary M
2009-09-01
Urinary tract infections (UTIs) may be subclinical or difficult to detect in dilute urine as sediment abnormalities may not be observed. In our laboratory, bacterial culture is automatically performed (reflex culture) on samples with urine specific gravity (USG)< or =1.013 to increase the likelihood of detecting infection. The value of routine culture of dilute urine, however, has not been fully assessed. The purpose of this retrospective study was to evaluate the frequency of positive bacterial cultures and analyze the diagnostic utility and cost-effectiveness of culture compared with routine sediment examination for detecting UTI in dilute urine specimens from dogs. Urinalysis and concurrent aerobic bacterial culture results were obtained from the electronic medical record system at the University of California-Davis Veterinary Medical Teaching Hospital for samples with USG< or =1.013 analyzed from July 1998 through January 2005. Urine collection method, presence of leukocytes and bacteria, bacterial culture results, and clinical diagnosis were recorded. Cost-effectiveness of reflex culture, based on low USG as the sole criterion, was evaluated. Of 1264 urine specimens, 106 (8.4%) had positive bacterial cultures. Using culture as the gold standard, sediment evaluation had a diagnostic sensitivity of 58.5% and specificity of 98.3% (diagnostic accuracy 94.9%). An additional cost of $60 per patient was incurred, leading to average annual costs of $11,668 for reflex bacterial cultures of all samples with low USG, regardless of collection method. Within our study population, 10 urine samples needed to be cultured for each true positive result. The sensitivity of urine sediment evaluation is low for UTI in dilute urine samples; however, reflex bacterial culture does not appear to be cost-effective in dogs with USG< or =1.013 in the absence of active urine sediment or high clinical suspicion for UTI.
GHSI EMERGENCY RADIONUCLIDE BIOASSAY LABORATORY NETWORK: SUMMARY OF A RECENT EXERCISE.
Li, Chunsheng; Ansari, Armin; Bartizel, Christine; Battisti, Paolo; Franck, Didier; Gerstmann, Udo; Giardina, Isabella; Guichet, Claude; Hammond, Derek; Hartmann, Martina; Jones, Robert L; Kim, Eunjoo; Ko, Raymond; Morhard, Ryan; Quayle, Deborah; Sadi, Baki; Saunders, David; Paquet, Francois
2016-11-01
The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop their collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency. A recent exercise was conducted to test the participating laboratories for their capabilities in screening and in vitro assay of biological samples, performing internal dose assessment and providing advice on medical intervention, if necessary, using a urine sample spiked with a single radionuclide, 241 Am. The laboratories were required to submit their reports according to the exercise schedule and using pre-formatted templates. Generally, the participating laboratories were found to be capable with respect to rapidly screening samples for radionuclide contamination, measuring the radionuclide in the samples, assessing the intake and radiation dose, and providing advice on medical intervention. However, gaps in bioassay measurement and dose assessment have been identified. The network may take steps to ensure that procedures and practices within this network be harmonised and a follow-up exercise be organised on a larger scale, with potential participation of laboratories from the networks coordinated by the International Atomic Energy Agency and the World Health Organization. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Urinalysis in children and adolescents.
Utsch, Boris; Klaus, Günter
2014-09-12
Urinalysis is the most commonly performed biochemical test in infancy and early childhood. The urine sample should be correctly obtained, age-specific aspects should be considered, and age-dependent reference values should be used. This review is based on a selective literature search in electronic databases, textbooks, and guidelines from Germany and abroad on the acquisition of urine samples and the performance of urinalysis in infancy and early childhood. The timing and mode of acquisition of the urine sample affect the assessment of hematuria, proteinuria, leukocyturia, nitrituria, and the uropathogenic bacterial colony count in the urine culture. Dipstick tests can be used for targeted screening for these features. The test results should be interpreted together with the findings of urine microscopy, the medical history, and the physical examination. Proteinuria should be quantified and differentiated; both of these things can be done either from collected urine or (especially in infants and young children) from a spontaneously voided urine sample, by determination of the protein/creatinine quotient. Orthostatic proteinuria in an adolescent requires no further evaluation or treatment. Hematuria should be characterized as either glomerular or non-glomerular erythrocyturia. Asymptomatic, isolated microhematuria in childhood is not uncommon and often transient; in the absence of a family history, it usually does not require an extensive work-up. Proteinuria combined with hematuria should arouse the suspicion of glomerulonephritis. Urinalysis in infancy and early childhood is a simple and informative diagnostic test as long as the urine sample has been obtained properly and the results are interpreted appropriately for this age group.
Brock, A Paige; Grunkemeyer, Vanessa L; Fry, Michael M; Hall, James S; Bartges, Joseph W
2013-12-01
To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.
Osada, Kazumi; Kurihara, Kenzo; Izumi, Hiroshi; Kashiwayanagi, Makoto
2013-01-01
Background The common grey wolf (Canis lupus) is found throughout the entire Northern hemisphere and preys on many kinds of mammals. The urine of the wolf contains a number of volatile constituents that can potentially be used for predator–prey chemosignalling. Although wolf urine is put to practical use to keep rabbits, rodents, deer and so on at bay, we are unaware of any prior behavioural studies or chemical analyses regarding the fear-inducing impact of wolf urine on laboratory mice. Methodology/Principal Findings Three wolf urine samples harvested at different times were used in this study. All of them induced stereotypical fear-associated behaviors (i.e., avoidance and freezing) in female mice. The levels of certain urinary volatiles varied widely among the samples. To identify the volatiles that provoked avoidance and freezing, behavioural, chemical, and immunohistochemical analyses were performed. One of the urine samples (sample C) had higher levels of 2,6-dimethylpyrazine (DMP), trimethylpyrazine (TMP), and 3-ethyl-2,5-dimethyl pyrazine (EDMP) compared with the other two urine samples (samples A and B). In addition, sample C induced avoidance and freezing behaviours more effectively than samples A and B. Moreover, only sample C led to pronounced expression of Fos-immunoreactive cells in the accessory olfactory bulb (AOB) of female mice. Freezing behaviour and Fos immunoreactivity were markedly enhanced when the mice were confronted with a mixture of purified DMP, TMP, and EDMP vs. any one pyrazine alone. Conclusions/Significance The current results suggest that wolf urinary volatiles can engender aversive and fear-related responses in mice. Pyrazine analogues were identified as the predominant active components among these volatiles to induce avoidance and freezing behaviours via stimulation of the murine AOB. PMID:23637901
Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G
2004-08-01
European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.
NHEXAS PHASE I MARYLAND STUDY--METALS IN URINE ANALYTICAL RESULTS
The Metals in Urine data set contains analytical results for measurements of up to 3 metals in 376 urine samples over 80 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning void of either Day ...
Kageura, Mitsuyoshi
2002-09-01
In this paper, the status quo of forensic toxicology in Japan and the West is surveyed and a strategy to address future goals of Japanese forensic toxicology is proposed. Forensic toxicology in the West consists of three main areas--post-mortem forensic toxicology, human-performance forensic toxicology and forensic urine drug testing. In Japan, post-mortem forensic toxicology is practiced in university forensic medicine departments while most of the human-performance forensic toxicology is carried out in police laboratories. However, at least at present, strictly controlled workplace urine drug testing is not being performed, despite the abuse of drugs even by uniformed members of the National Defence Forces and police. For several years, the author has been introducing Western forensic toxicology guidelines and recommendations, translated into Japanese with the help of Western forensic toxicologists, to Japanese forensic toxicologists. Western forensic toxicology practice is at an advanced stage, whereas Japanese practice is in a critical condition and holds many problems awaiting solution, as exemplified by the urine drug testing in police laboratories. There is never any sample left for re-examination by the defence in all cases, though the initial volume of the urine sample available for examination is 30-50 ml. Only one organisation carries out everything from sampling to reporting and, in addition, the parent drug and its metabolites are not quantified. It is clear that the police laboratories do not work within good laboratory practice guidelines, nor do they have quality manuals or standard operating procedures manuals. A basic change in Japanese forensic toxicology practice is now essential. The author strongly recommends that, first of all, Japanese toxicologists should prepare forensic toxicology guidelines based on the Western models. The guidelines would progress the following objectives for forensic toxicology laboratories: 1) to have documented good laboratory practice standards; 2) to have a quality control system including a quality manual and standard operating procedures manual; 3) to have some degree of compulsion to implement quality assurance both through their own internal efforts and by appropriate remedial actions based on the results of an external proficiency testing scheme. For forensic toxicologists, the implications are that they should be: 1) responsible for ensuring that laboratory practices are performed under satisfactory conditions and 2) required to be certified as a forensic toxicology specialist in order to prove their forensic toxicology ability. For their part, governments should: 1) carry out administrative reforms related to forensic toxicology; 2) simplify the procedure for obtaining certified reference materials; 3) introduce a strict workplace urine drug testing programme for government employees, at least for those related to law enforcement. When all of these objectives have been realised, the specific goal will be achieved through which Japanese forensic toxicology is able, in practice, to fulfill its responsibility to society.
Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples
Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely
2008-01-01
Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients. Moreover, PCR has enabled us to use residue volumes of urine samples collected by non invasive, non sterile methods, what is technically adequate as GBS is not part of the normal urine flora, thus avoiding invasive procedures such as suprapubic bladder punction or transurethral catheterization. At the same time, the use of urine instead of blood samples could help preventing newborns blood spoliation. PMID:24031170
Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?
Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok
2012-01-01
Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881
Peter, Jonathan G.; Theron, Grant; Muchinga, Tapuwa E.; Govender, Ureshnie; Dheda, Keertan
2012-01-01
Background Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients. Methodology/Principal Findings 281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity). Conclusions/Significance This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity. PMID:22815718
Liu, Junwei; Deng, Zhifen; Zhu, Zuoyi; Wang, Yong; Wang, Guoqing; Sun, Yu-An; Zhu, Yan
2017-12-15
A two-dimensional ion chromatography system was developed for the determination of γ-hydroxybutyrate (GHB) in human urine samples. Ion exclusion chromatography was used in the first dimensional separation for elimination of urine matrices and detection of GHB above 10mgL -1 , ion exchange chromatography was used in the second dimensional separation via column-switching technique for detection of GHB above 0.08mgL -1 . Under the optimized chromatographic conditions, the ion exclusion and ion exchange chromatography separation system exhibited satisfactory repeatability (RSD<3.1%, n=6) and good linearity in the range of 50-1000mgL -1 and 0.5-100mgL -1 , respectively. By this method, concentrations of GHB in the selected human urine samples were detected in the range of 0-1.57mgL -1 . The urine sample containing 0.89mgL -1 GHB was selected to evaluate the accuracy; the spiked recoveries of GHB were 95.9-102.8%. The results showed that the two-dimensional ion chromatography system was convenient and practical for the determination of GHB in human urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Pillay, Pavitra; Taylor, Myra; Zulu, Siphosenkosi G.; Gundersen, Svein G.; Verweij, Jaco J.; Hoekstra, Pytsje; Brienen, Eric A. T.; Kleppa, Elisabeth; Kjetland, Eyrun F.; van Lieshout, Lisette
2014-01-01
Schistosoma haematobium eggs and Schistosoma DNA levels were measured in urine samples from 708 girls recruited from 18 randomly sampled primary schools in South Africa. Microscopic analysis of two 10-mL urine subsamples collected on three consecutive days confirmed high day-to-day variation; 103 (14.5%) girls had positive results at all six examinations, and at least one positive sample was seen in 225 (31.8%) girls. Schistosoma-specific DNA, which was measured in a 200-μL urine subsample by using real-time polymerase chain reaction, was detected in 180 (25.4%) cases, and levels of DNA corresponded significantly with average urine egg excretion. In concordance with microscopic results, polymerase chain reaction results were significantly associated with history of gynecologic symptoms and confirmed highly focal distribution of urogenital schistosomiasis. Parasite-specific DNA detection has a sensitivity comparable to single urine microscopy and could be used as a standardized high-throughput procedure to assess distribution of urogenital schistosomiasis in relatively large study populations by using small sample volumes. PMID:24470560
Development of Technologies for Early Detection and Stratification of Breast Cancer
2014-10-01
cancer. Similar screening has been done in urine samples with CYR61 and LCN2 (Figure 2a-b). The Moses lab provided breast cancer urine samples and two ...diseased samples, while CYR61 appears to have two different populations whereas diseased urine samples have lower levels of the protein present. More... system for eDAR so that each isolated cell can be deposited into a well of a 96-well plate for high-throughput downstream single-cell digital
Aoki, Kimiko; Tanaka, Hiroyuki; Ueki, Makoto
2017-08-01
When the tampering of a urine sample is suspected in doping control, personal identification of the sample needs to be determined by short tandem repeat (STR) analysis using DNA. We established a method for extracting DNA from urine samples stored at -20 °C without using any additives or procedures, which is consistent with how samples are required to be managed for doping control. The method, using the Puregene® Blood Core kit followed by NucleoSpin® gDNA Clean-up or NucleoSpin® gDNA Clean-up XS kit, does not need any special instrument and can provide a purified extract with high-quality DNA from up to 40 mL of urine suitable for STR analysis using an AmpFlSTR® Identifiler® PCR amplification kit. Storing urine at -20 °C is detrimental to the stability of DNA. The DNA concentration of preserved urine could not be predicted by specific gravity or creatinine level at the time of urine collection. The DNA concentration of a purified extract (10 μL) was required to be >0.06 ng/μL to ensure a successful STR analysis. Thus, the required extraction volumes of urine preserved for 3-7 years at -20 °C were estimated to be 30 mL and 20 mL to succeed in at least 86% of men and 91% of women, respectively. Considering the long half-life of DNA during long-term preservation, our extraction method is applicable to urine samples stored even for 10 years, which is currently the storage duration allowed (increased from 8 years) before re-examination in doping control. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Immunoreactive LH in long-term frozen human urine samples.
Singh, Gurmeet Kaur Surindar; Jimenez, Mark; Newman, Ron; Handelsman, David J
2014-04-01
Urine provides a convenient non-invasive alternative to blood sampling for measurement of certain hormones. Urinary luteinizing hormone (LH) measurements have been used for endocrinology research and anti-doping testing. However, the commercially available LH immunoassays are developed and validated for human blood samples but not urine so that LH assays intended for use with urine samples need thorough validation. Therefore, the present study evaluated the measurement of urinary LH immunoreactivity using previously validated immunofluorometric (IF) and immunochemiluminometric (ICL) LH assays after prolonged frozen storage. LH was measured in serial urine samples following administration of a single injection of one of two doses of recombinant human chorionic hormone (rhCG) with assays run at the end of study (2008) and again after four years of frozen (-20 °C) storage where samples were stored without adding preservatives. The ICL assay showed quantitatively reproducible LH measurements after prolonged -20 °C storage. However, the IF immunoassay gave consistently lower LH levels relative to ICL (2008) with a further proportionate reduction after four years of sample storage (2012). Yet, both the assays displayed similar patterns of the time-course of urine LH measurement both before and after four years of frozen storage. In conclusion, we found that both immunoassays are suitable for urinary LH measurements with ICL assay being more robust for quantitative urinary LH measurement such as for anti-doping purposes, whereas the IF could be applicable for research studies where urine LH levels are compared within-study but not in absolute terms. Copyright © 2013 John Wiley & Sons, Ltd.
Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan
2016-06-05
In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Urine benzodiazepines screening of involuntarily drugged and robbed or raped patients.
Boussairi, A; Dupeyron, J P; Hernandez, B; Delaitre, D; Beugnet, L; Espinoza, P; Diamant-Berger, O
1996-01-01
This study involved 35 patients who claimed to have been drugged before being robbed or raped, despite urine negative toxicologic screening by immunoenzymatic methods. The urines were frozen for further investigations, including enzymatic hydrolysis of urinary conjugates, liquid-solid extraction and, finally, immunoenzymatic screening of concentrated urine extract. Urine benzodiazepines were analyzed by immunoenzymatic assay before and after enzymatic hydrolysis combined with extraction. On direct immunoenzymatic screening, 17 of the 35 urine samples were benzodiazepine positive. Enrichment of preserved specimens improved the detection threshold from 200 ng/mL to 50 ng/mL and 10 of the 18 negative urines became positive. This method allowed us to demonstrate the benzodiazepines in half of previously negative urine samples. Benzodiazepine screening is particularly problematic because of low dosage, rapid elimination, failure to detect conjugated metabolites by immunoenzymatic reagents and high threshold of sensitivity for certain substances.
Microanalyzer for Biomonitoring of Lead (Pb) in Blood and Urine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yantasee, Wassana; Timchalk, Chuck; Lin, Yuehe
2007-01-01
Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. The state-of-the-art ICP-MS instruments analyze metals in laboratories, resulting in lengthy turn around time, and are expensive. In response to the growing need for metal analyzer for on-site, real-time monitoring of trace metals in individuals, we developed a portable microanalyzer based on flow-injection/adsorptive stripping voltammetry and used it to analyze Pb in rat blood and urine. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with the suitablemore » sample pretreatment and the turbulent flowing of Pb contained blood and urine onto the glassy electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. There was no matrix effect on the voltammetric Pb signals even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration range relevant to Pb exposure levels in human (0-20 ppb in 10%-blood samples, 0-50 ppb in 50%-urine samples). The device had excellent sensitivity and reproducibility; Pb detection limits were 0.54 ppb and 0.42 ppb, and % RSDs were 4.9 and 2.4 in 50%-urine and 10%-blood samples, respectively. It offered a high throughput (3 min per sample) and had economical use of samples (60 ?L per measurement), making the collection of blood being less invasive especially to children, and had low reagent consumption (1 ?g of Hg per measurement), thus minimizing the health concerns of mercury use. Being miniaturized in size, the microanalyzer is portable and field-deployable. Thus, it has a great potential to be the next-generation analyzer for biomonitoring of toxic metals.« less
Optimizing Urine Processing Protocols for Protein and Metabolite Detection.
Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K
In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Healthy women provided multiple urine samples during the same day. Women collected their first morning (1 st AM) void and another "random void". Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Ten Caucasian women between 35-65 years of age provided paired 1 st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1 st AM compared to random "spot" voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4°C or RT storage temperature.
Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L
2017-08-22
The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD < 7%). Holding time studies in unpreserved urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.
Diagnosis and effects of urine contamination in cooled-extended stallion semen.
Ellerbrock, R; Canisso, I; Feijo, L; Lima, F; Shipley, C; Kline, K
2016-04-15
Urospermia is known to affect semen quality in many mammals, including stallions. Determinations of semen pH and creatinine and urea concentrations have been used to diagnose urine contamination in raw stallion semen. Unfortunately, practitioners suspecting urine contamination in cooled-shipped samples have no proven means to confirm the presence of urine. Therefore, the objectives of this study were (1) to assess the effects of urine contamination on sperm motility of extended fresh and cooled-stored stallion semen, (2) to evaluate the usefulness of semen color, odor, pH, and creatinine and urea concentrations for urospermia diagnosis, and (3) to evaluate the accuracy of a commercial blood urea nitrogen test strip in diagnosing urine contamination in extended-cooled stallion semen. Thirty-seven ejaculates were obtained from 11 stallions with no history of urospermia before division into 5 mL aliquots, and contamination with stallion urine. Each resulting sample was assessed for sperm motility, color, odor, pH, creatinine, and urea nitrogen concentration using both a semiquantitative test strip (Azostix), and a quantitative automated analyzer before and after cooling for 24 hour. Sperm motility parameters, pH, and creatinine and urea concentrations were analyzed using mixed models. Urine contamination decreased total and progressive motility in all samples before and after cooling (P < 0.05). Mean control total motility was 80% at 0 hour and 67% at 24 hours, whereas urine-contaminated samples ranged from 30% to 71% at 0 hour and 27% to 61% at 24 hours. Control mean urea (29 mg/dL) and creatinine (0.6 mg/dL) concentrations were significantly different (P < 0.05) from all urine-contaminated samples (158 mg/dL and 11.6 mg/dL, respectively) at 0 hour. Similarly, control mean urea (8 mg/dL) and creatinine (0.9 mg/dL) concentrations were significantly different than all urine-contaminated samples at 24 hours. Odor assessment presented moderate sensitivity (65%) and high specificity (100%), while color assessment presented low sensitivity (47%) and moderate specificity (79%) for urine in extended semen. Azostix strips were highly sensitive (95%) and specific (97%). Assessment of color, odor, and pH are not reliable methods to diagnose urine in experimentally contaminated cooled-stored stallion semen. Sperm motility parameters (in raw and cooled semen) are significantly reduced by the presence of urine in a concentration dependent. The results of the present study indicated that determination of urea and creatinine concentrations can be used to diagnose urospermia and that Azostix can be used as a point care method for diagnosing urine contamination in extended cooled stallion semen. Copyright © 2016 Elsevier Inc. All rights reserved.
Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi
2005-01-01
We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.
Fully automated methods for the determination of hydrochlorothiazide in human plasma and urine.
Hsieh, J Y; Lin, C; Matuszewski, B K; Dobrinska, M R
1994-12-01
LC assays utilizing fully automated sample preparation procedures on Zymark PyTechnology Robot and BenchMate Workstation for the quantification of hydrochlorothiazide (HCTZ) in human plasma and urine have been developed. After aliquoting plasma and urine samples, and adding internal standard (IS) manually, the robot executed buffer and organic solvent addition, liquid-liquid extraction, solvent evaporation and on-line LC injection steps for plasma samples, whereas, BenchMate performed buffer and organic solvent addition, liquid-liquid and solid-phase extractions, and on-line LC injection steps for urine samples. Chromatographic separations were carried out on Beckman Octyl Ultrasphere column using the mobile phase composed of 12% (v/v) acetonitrile and 88% of either an ion-pairing reagent (plasma) or 0.1% trifluoroacetic acid (urine). The eluent from the column was monitored with UV detector (271 nm). Peak heights for HCTZ and IS were automatically processed using a PE-Nelson ACCESS*CHROM laboratory automation system. The assays have been validated in the concentration range of 2-100 ng ml-1 in plasma and 0.1-20 micrograms ml-1 in urine. Both plasma and urine assays have the sensitivity and specificity necessary to determine plasma and urine concentrations of HCTZ from low dose (6.25/12.5 mg) administration of HCTZ to human subjects in the presence or absence of losartan.
Hendrikx, Jeroen J M A; Rosing, Hilde; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H
2014-02-01
A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human feces and urine is described. The drugs were extracted from 200 μL urine or 50 mg feces followed by high-performance liquid chromatography analysis coupled with positive ionization electrospray tandem mass spectrometry. The validation program included calibration model, accuracy and precision, carry-over, dilution test, specificity and selectivity, matrix effect, recovery and stability. Acceptance criteria were according to US Food and Drug Administration guidelines on bioanalytical method validation. The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel, 2-2000 ng/mL for ritonavir in urine, 2-2000 ng/mg for paclitaxel and docetaxel, and 8-8000 ng/mg for ritonavir in feces. Inter-assay accuracy and precision were tested for all analytes at four concentration levels and were within 8.5% and <10.2%, respectively, in both matrices. Recovery at three concentration levels was between 77 and 94% in feces samples and between 69 and 85% in urine samples. Method development, including feces homogenization and spiking blank urine samples, are discussed. We demonstrated that each of the applied drugs could be quantified successfully in urine and feces using the described assay. The method was successfully applied for quantification of the analytes in feces and urine samples of patients. Copyright © 2013 John Wiley & Sons, Ltd.
Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine.
Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim
2015-01-01
Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable.
Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine
Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim
2015-01-01
Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable. PMID:26208298
Kitagawa, Koichi; Shigemura, Katsumi; Onuma, Ken-Ichiro; Nishida, Masako; Fujiwara, Mayu; Kobayashi, Saori; Yamasaki, Mika; Nakamura, Tatsuya; Yamamichi, Fukashi; Shirakawa, Toshiro; Tokimatsu, Issei; Fujisawa, Masato
2018-03-01
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) contributes to rapid identification of pathogens in the clinic but has not yet performed especially well for Gram-positive cocci (GPC) causing complicated urinary tract infection (UTI). The goal of this study was to investigate the possible clinical use of MALDI-TOF MS as a rapid method for bacterial identification directly from urine in complicated UTI. MALDI-TOF MS was applied to urine samples gathered from 142 suspected complicated UTI patients in 2015-2017. We modified the standard procedure (Method 1) for sample preparation by adding an initial 10 minutes of ultrasonication followed by centrifugation at 500 g for 1 minutes to remove debris such as epithelial cells and leukocytes from the urine (Method 2). In 133 urine culture-positive bacteria, the rate of corresponded with urine culture in GPC by MALDI-TOF MS in urine with standard sample preparation (Method 1) was 16.7%, but the modified sample preparation (Method 2) significantly improved that rate to 52.2% (P=.045). Method 2 also improved the identification accuracy for Gram-negative rods (GNR) from 77.1% to 94.2% (P=.022). The modified Method 2 significantly improved the average MALDI score from 1.408±0.153 to 2.166±0.045 (P=.000) for GPC and slightly improved the score from 2.107±0.061 to 2.164±0.037 for GNR. The modified sample preparation for MALDI-TOF MS can improve identification accuracy for complicated UTI causative bacteria. This simple modification offers a rapid and accurate routine diagnosis for UTI, and may possibly be a substitute for urine cultures. © 2017 Wiley Periodicals, Inc.
Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.
Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M
2017-09-01
Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Automated biowaste sampling system urine subsystem operating model, part 1
NASA Technical Reports Server (NTRS)
Fogal, G. L.; Mangialardi, J. K.; Rosen, F.
1973-01-01
The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.
Salgado-Petinal, Carmen; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael
2005-07-01
In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.
Chen, Guixia; Chen, Xiaoxin; Yan, Chonghuai; Wu, Xingdong; Zeng, Guozhang
2014-01-01
Aim: The average mercury load in children under 7-years old was determined in a populated but not overly industrial coastal area in China. Methods: 395 blood samples, 1072 urine samples, and 581 hair samples were collected from 1076 children, aged 0 to 6 years, from eight representative communities of Xiamen, China. Mercury levels in the samples were surveyed. Results: The 95% upper limits of mercury in blood, urine, and hair for the children were 2.30, 1.50 and 2100.00 μg/kg, respectively. Levels tended to increase with age. Correlation analyses showed that mercury levels in blood and urine correlated with those in hair (n = 132), r = 0.49, p < 0.0001 and r = 0.20, p = 0.0008; however, blood mercury levels did not correlate with urine levels (n = 284), r = 0.07, p = 0.35. Conclusions: Surveying the average mercury load in children 0 to 6 years, and the 95% upper limit value of mercury in their blood, urine, and hair should help guide risk assessment and health management for children. PMID:25419876
Major Odorants Released as Urinary Volatiles by Urinary Incontinent Patients
Pandey, Sudhir Kumar; Kim, Ki-Hyun; Choi, Si On; Sa, In Young; Oh, Soo Yeon
2013-01-01
In this study, volatile urinary components were collected using three different types of samples from patients suffering from urinary incontinence (UI): (1) urine (A); (2) urine + non-used pad (B); and (3) urine + used pad (C). In addition, urine + non-used pad (D) samples from non-patients were also collected as a reference. The collection of urinary volatiles was conducted with the aid of a glass impinger-based mini-chamber method. Each of the four sample types (A through D) was placed in a glass impinger and incubated for 4 hours at 37 °C. Ultra pure air was then passed through the chamber, and volatile urine gas components were collected into Tedlar bags at the other end. These bag samples were then analyzed for a wide range of VOCs and major offensive odorants (e.g., reduced sulfur compounds (RSCs), carbonyls, trimethylamine (TMA), ammonia, etc.). Among the various odorants, sulfur compounds (methanethiol and hydrogen sulfide) and aldehydes (acetaldehyde, butylaldehyde, and isovaleraldehyde) were detected above odor threshold and predicted to contribute most effectively to odor intensity of urine incontinence. PMID:23823973
Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew
2007-01-01
The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.
NASA Technical Reports Server (NTRS)
Wingard, C. D.
2015-01-01
On International Space Station (ISS), the Urine Processor Assembly (UPA) converts human urine and flush water into potable water. The urine is acid-pretreated primarily to control microbial growth. In recent years, the sulfuric acid (H2SO4) pretreatment was believed to be largely responsible for producing salt crystals capable of plugging filters in UPA components and significantly reducing the percentage of water recovery from urine. In 2012, ISS management decided to change the acid pretreatment for urine from sulfuric to phosphoric with the goal of eliminating or minimizing formation of salt crystals. In 2013-2014, as part of the qualification of the phosphoric acid (H3PO4) formulation, samples of 12 nonmetallic materials used in UPA components were immersed for up to one year in pretreated urine and brine solutions made with the new H3PO4 formulation. Dynamic mechanical analysis (DMA) was used to measure modulus (stiffness) of the immersed samples compared to virgin control samples. Such compatibility data obtained by DMA for the H3PO4-based solutions were compared to DMA data obtained for the H2SO4-based solutions in 2002-2003.
Flow meter urine testing: a practical proposition in patients attending for urodynamics?
Hashim, Hashim; Abrams, Paul
2006-05-01
To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.
Reproducibility of urinary biomarkers in multiple 24-h urine samples.
Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C
2017-01-01
Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses' Health Study), NHSII (Nurses' Health Study II), and Health Professionals Follow-Up Study. In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. © 2017 American Society for Nutrition.
Reproducibility of urinary biomarkers in multiple 24-h urine samples123
Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C
2017-01-01
Background: Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. Objective: We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. Design: We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses’ Health Study), NHSII (Nurses’ Health Study II), and Health Professionals Follow-Up Study. Results: In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. Conclusions: These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. PMID:28049663
Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh
2016-01-01
Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.
A study examining the bias of albumin and albumin/creatinine ratio measurements in urine.
Jacobson, Beryl E; Seccombe, David W; Katayev, Alex; Levin, Adeera
2015-10-01
The objective of the study was to examine the bias of albumin and albumin/creatinine (ACR) measurements in urine. Pools of normal human urine were augmented with purified human serum albumin to generate a series of 12 samples covering the clinical range of interest for the measurement of ACR. Albumin and creatinine concentrations in these samples were analyzed three times on each of 3 days by 24 accredited laboratories in Canada and the USA. Reference values (RV) for albumin measurements were assigned by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) comparative method and gravimetrically. Ten random urine samples (check samples) were analyzed as singlets and albumin and ACR values reported according to the routine practices of each laboratory. Augmented urine pools were shown to be commutable. Gravimetrically assigned target values were corrected for the presence of endogenous albumin using the LC-MS/MS comparative method. There was excellent agreement between the RVs as assigned by these two methods. All laboratory medians demonstrated a negative bias for the measurement of albumin in urine over the concentration range examined. The magnitude of this bias tended to decrease with increasing albumin concentrations. At baseline, only 10% of the patient ACR values met a performance limit of RV ± 15%. This increased to 84% and 86% following post-analytical correction for albumin and creatinine calibration bias, respectively. International organizations should take a leading role in the standardization of albumin measurements in urine. In the interim, accuracy based urine quality control samples may be used by clinical laboratories for monitoring the accuracy of their urinary albumin measurements.
Berg, Wolfgang; Bechler, Robin; Laube, Norbert
2009-01-01
Since its first publication in 2000, the BONN-Risk-Index (BRI) has been successfully used to determine the calcium oxalate (CaOx) crystallization risk from urine samples. To date, a BRI-measuring device, the "Urolizer", has been developed, operating automatically and requiring only a minimum of preparation. Two major objectives were pursued: determination of Urolizer precision, and determination of the influence of 24-h urine storage at moderate temperatures on BRI. 24-h urine samples from 52 CaOx stone-formers were collected. A total of 37 urine samples were used for the investigation of Urolizer precision by performing six independent BRI determinations in series. In total, 30 samples were taken for additional investigation of urine storability. Each sample was measured thrice: directly after collection, after 24-h storage at T=21 degrees C, and after 24-h cooling at T=4 degrees C. Outcomes were statistically tested for identity with regard to the immediately obtained results. Repeat measurements for evaluation of Urolizer precision revealed statistical identity of data (p-0.05). 24-h storage of urine at both tested temperatures did not significantly affect BRI (p-0.05). The pilot-run Urolizer shows high analytical reliability. The innovative analysis device may be especially suited for urologists specializing in urolithiasis treatment. The possibility for urine storage at moderate temperatures without loss of analysis quality further demonstrates the applicability of the BRI method.
Mining the human urine proteome for monitoring renal transplant injury
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sigdel, Tara K.; Gao, Yuqian; He, Jintang
The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used inmore » the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.« less
Rennie, Robert P; Turnbull, Lee-Ann; Gauchier-Pitts, Kaylee; Bennett, Tracy; Dyrland, Debbie; Blonski, Susan
2016-08-01
The ability to isolate and identify causative agents of urinary tract infections relies primarily on the quality of the urine sample that is submitted to the microbiology. The most important factors are the method of collection, the maintenance of viability of the potential pathogens during transport, and standardization of the culturing of the urine sample. This report is a composite of several investigations comparing collection and transport on urine culture paddles, with a preservative urine sponge (Uriswab), and a comparison of Uriswab with the BD preservative transport tube as methods of preservation of urinary pathogens. Primary studies showed that Uriswab maintained significantly more urinary pathogens than the urine culture paddle with fewer mixed or contaminated cultures. The two preservative transport systems were comparable for maintenance of viability of the pathogens, but there were fewer mixed cultures when samples were collected with Uriswab. This study confirms the importance of a standard volume of 1 μL of urine for culture. Copyright © 2016 Elsevier Inc. All rights reserved.
Excretion profile of boldenone in urine of veal calves fed two different milk replacers.
Draisci, R; Merlanti, R; Ferretti, G; Fantozzi, L; Ferranti, C; Capolongo, F; Segato, S; Montesissa, C
2007-03-14
The residue profiles of 17alpha-/17beta-boldenone conjugated (17alpha/beta-Bol) and ADD were investigated by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in urine of male veal calves fed two commercial milk replacers, with different content of cholesterol and phytosterols. The urine samples were collected within 4 h after feeding and further from all the animals. Detectable amounts of 17alpha-Bol conjugated were measured in urine collected from all calves, but the concentrations of 17alpha-Bol were higher in urine from calves receiving the milk replacer with the greater amount of phytosterols. During the whole experiment, 17beta-Bol and ADD were never detected in urine samples collected.
Occupational exposure to cytotoxic drugs in two UK oncology wards
Ziegler, E; Mason, H; Baxter, P
2002-01-01
Aims: To investigate the potential exposure to cytotoxic drugs of staff on two oncology wards in a large district, UK hospital under normal working conditions. Methods: Cytotoxic drug exposure was monitored in urine samples, surface wipes, and on disposable gloves by using a number of commonly used marker drugs, namely cyclophosphamide, ifosfamide, methotrexate, and the platino coordinated drugs. Questionnaire data on their work practices, potential exposure, use of protective personal equipment, and relevant training were collected from nursing, domestic, and clerical staff on two oncology wards. Results: The majority of staff were female with a mean age of 31 years. Roughly half of the staff studied were specifically trained nurses with an average of 3.5 years experience of administering cytotoxic drugs. No cytotoxic drug preparation or reconstitution was carried out on the wards. Disposable gloves, plastic armlets and aprons, but not eye protection, were invariably worn where there was potential exposure to cytotoxics. No cytotoxic drug was detected in any of the staff's urine samples. Isolated disposable latex gloves from nurses administering drugs showed some contamination, as did some surfaces within the wards' sluice rooms, but not in the ward areas where the drugs were stored and checked prior to administration. Conclusions: The risk management strategies in place, including use of personal protective equipment, staff training, and other organisational measures, have ensured that internal exposure is lower than the detection limits for the current biological monitoring methods. Levels of contamination appear significantly lower than earlier, non-UK published studies where different risk management strategies were in place and, in particular, ward staff may have been involved in some degree of cytotoxic drug reconstitution. PMID:12205233
Sample handling for mass spectrometric proteomic investigations of human urine.
Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid
2008-09-01
Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...
Performance of Copan WASP for Routine Urine Microbiology
Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.
2015-01-01
This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255
Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi
2017-12-01
Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.
Fidani, M; Gamberini, M C; Pasello, E; Palazzoli, F; De Iuliis, P; Montana, M; Arioli, F
2009-01-01
Proper storage conditions of biological samples are fundamental to avoid microbiological contamination that can cause chemical modifications of the target analytes. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method through direct injection of diluted samples, without prior extraction, was used to evaluate the stability of phase II metabolites of boldenone and testosterone (glucuronides and sulphates) in intentionally poorly stored equine urine samples. We also considered the stability of some deuterated conjugated steroids generally used as internal standards, such as deuterated testosterone and epitestosterone glucuronides, and deuterated boldenone and testosterone sulphates. The urines were kept for 1 day at room temperature, to mimic poor storage conditions, then spiked with the above steroids and kept at different temperatures (-18 degrees C, 4 degrees C, room temperature). It has been possible to confirm the instability of glucuronide compounds when added to poorly stored equine urine samples. In particular, both 17beta- and 17alpha-glucuronide steroids were exposed to hydrolysis leading to non-conjugated steroids. Only 17beta-hydroxy steroids were exposed to oxidation to their keto derivatives whereas the 17alpha-hydroxy steroids were highly stable. The sulphate compounds were completely stable. The deuterated compounds underwent the same behaviour as the unlabelled compounds. The transformations were observed in urine samples kept at room temperature and at a temperature of 4 degrees C (at a slower rate). No modifications were observed in frozen urine samples. In the light of the latter results, the immediate freezing at -18 degrees C of the collected samples and their instant analysis after thawing is the proposed procedure for preventing the transformations that occur in urine, usually due to microbiological contamination. (c) 2008 John Wiley & Sons, Ltd.
Bao, T M; Tian, Y; Wang, L X; Wu, T; Lu, L N; Ma, H Y; Wang, L
2018-02-20
Objective: To investigate the levels of lanthanum, cerium, praseodymium, and neodymium in the blood, urine, and hair samples from residents in the rare earth mining area of a city in China, and to provide a scientific basis for the control of rare earth pollution and the protection of population health. Methods: A total of 147 residents who had lived in the rare earth mining area of a city for a long time were selected as the exposure group, and 108 residents in Guyang County of this city who lived 91 km away from the rare earth mining area were selected as the control group. Blood, urine, and hair samples were collected from the residents in both groups. Inductively coupled plasma mass spectrometry was used to determine the content of lanthanum, cerium, praseodymium, and neodymium in blood, urine, and hair samples. Results: In the exposure group, the median levels of lanthanum, cerium, praseodymium, and neodymium were 0.854, 1.724, 0.132, and 0.839 μg/L, respectively, in blood samples, 0.420, 0.920, 0.055, and 0.337 μg/L, respectively, in urine samples, and 0.052, 0.106, 0.012, and 0.045 μg/g, respectively, in hair samples. The exposure group had significantly higher levels of the four rare earth elements in blood, urine, and hair samples than the control group ( P <0.01) . Conclusion: The residents in the rare earth mining area of this city have higher content of lanthanum, cerium, praseodymium, and neodymium in blood, urine, and hair than those in the non-mining area; the content of cerium is highest, followed by lanthanum, neodymium, and praseodymium.
Morgan, Marsha K; Sobus, Jon R; Barr, Dana Boyd; Croghan, Carry W; Chen, Fu-Lin; Walker, Richard; Alston, Lillian; Andersen, Erik; Clifton, Matthew S
2016-01-01
Pyrethroid insecticides are widely used to control insects in both agricultural and residential settings worldwide. Few data are available on the temporal variability of pyrethroid metabolites in the urine of non-occupationally exposed adults. In this work, we describe the study design and sampling methodology for the Pilot Study to Estimate Human Exposures to Pyrethroids using an Exposure Reconstruction Approach (Ex-R study). Two major objectives were to quantify the concentrations of several pyrethroid metabolites in bedtime, first morning void (FMV), and 24-h urine samples as concentration (wet weight), specific-gravity (SG) corrected, creatinine (CR) corrected, and excretion rate values for 50 Ex-R adults over a six-week monitoring period and to determine if these correction approaches for urine dilution reduced the variability of the biomarker levels. The Ex-R study was conducted at the United States Environmental Protection Agency's Human Studies Facility in Chapel Hill, North Carolina USA and at participants' homes within a 40-mile radius of this facility. Recruitment of participants and field activities occurred between October 2009 and May 2011. Participants, ages 19-50 years old, provided daily food, activity, and pesticide-use diaries and collected their own urine samples (bedtime, FMV, and 24-h) during weeks 1, 2, and 6 of a six-week monitoring period. A total of 2503 urine samples were collected from the study participants. These samples were analyzed for the pyrethroid metabolites 3-phenoxybenzoic acid (3-PBA), cis/trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-cyclopropane carboxylic acid (cis/trans-DCCA), and 2-methyl-3-phenylbenzoic acid (MPA) using high performance liquid chromatography/tandem mass spectrometry. Only 3-PBA was frequently detected (>50%) in the adult urine samples. Median urinary 3-PBA levels were 0.88 ng/mL, 0.96 ng/mL-SG, 1.04 ng/mg, and 1.04 ng/min for concentration, SG-corrected, CR-corrected, and excretion rate values, respectively, across all urine samples. The results showed that median urinary 3-PBA concentrations were consistently the lowest in FMV samples (0.77 ng/mL, 0.68 ng/mL-SG, 0.68 ng/mg, and 0.58 ng/min) and the highest in 24-h samples (0.92 ng/mL, 1.06 ng/mL-SG, 1.18 ng/mg, and 1.19 ng/min) across all four methods. Intraclass correlation coefficient (ICC) estimates for 3-PBA indicated poor reproducibility (<0.22) for all urine sample types and methods over a day, week, and six weeks. Correcting for urine sample dilution, based on either SG, CR or urine output, introduced additional measurement variability both between- and within-individuals. These results indicate that a single measure of urinary 3-PBA was not sufficient to characterize average exposure regardless of sample type, correction method, and time frame of collection. In addition, the study results can be used to inform the design of exposure characterization strategies in relevant environmental epidemiology studies in the future. Published by Elsevier Inc.
Fan, S; Zou, J H; Miao, H; Zhao, Y F; Chen, H J; Zhao, R; Wu, Y N
2013-01-01
A liquid chromatography-linear ion-trap spectrometry (LC-MS³) method using β-receptor molecular-imprinted polymer (MIP) solid-phase extraction (SPE) as clean-up was developed to determine simultaneously and confirmatively residues of 25 β₂-agonists and 21 β-blockers in urine samples. Urine samples were subjected to enzymatic hydrolysis by β-glucoronidase/arylsulphatase, and then extracted with perchloric acid. Sample clean-up was performed using β-receptor MIP SPE. A Supelco Ascentis® express Rp-Amide column was used to separate the analytes, and MS³ detection used an electrospray ionisation source in positive-ion mode. Recovery studies were carried out using blank urine samples fortified with the 46 analytes at the levels of 0.5, 1.0 and 2.0 μg l⁻¹. Recoveries were obtained ranging from 60.1% to 109.9% with relative standard deviations (RSDs, n = 7) from 0.5% to 19.4%. The limits of detection (LODs) and limits of quantitation (LOQs) of the 46 analytes in urine were 0.02-0.18 and 0.05-0.60 μg l⁻¹, respectively. As a result of the selective clean-up by MIP SPE and MS³ detection of the target drugs, the sensitivity and accuracy of the present method was high enough for monitoring β₂-agonist and β-blocker residues in urine samples. Satisfactory results were obtained in the process of the determination of positive urine samples.
Hoppin, Jane A; Ulmer, Ross; Calafat, Antonia M; Barr, Dana B; Baker, Susan V; Meltzer, Helle M; Rønningen, Kjersti S
2006-01-01
Collection of urine samples in human studies involves choices regarding shipping, sample preservation, and storage that may ultimately influence future analysis. As more studies collect and archive urine samples to evaluate environmental exposures in the future, we were interested in assessing the impact of urine preservative, storage temperature, and time since collection on nonpersistent contaminants in urine samples. In spiked urine samples stored in three types of urine vacutainers (no preservative, boric acid, and chlorhexidine), we measured five groups of contaminants to assess the levels of these analytes at five time points (0, 24, 48, and 72 h, and 1 week) and at two temperatures (room temperature and 4 degrees C). The target chemicals were bisphenol A (BPA), metabolites of organophosphate (OP), carbamate, and pyrethroid insecticides, chlorinated phenols, and phthalate monoesters, and were measured using five different mass spectrometry-based methods. Three samples were analyzed at each time point, with the exception of BPA. Repeated measures analysis of variance was used to evaluate effects of storage time, temperature, and preservative. Stability was summarized with percent change in mean concentration from time 0. In general, most analytes were stable under all conditions with changes in mean concentration over time, temperature, and preservative being generally less than 20%, with the exception of the OP metabolites in the presence of boric acid. The effect of storage temperature was less important than time since collection. The precision of the laboratory measurements was high allowing us to observe small differences, which may not be important when categorizing individuals into broader exposure groups.
Nilsson, Gunnel H; Kugelberg, Fredrik C; Ahlner, Johan; Kronstrand, Robert
2014-01-01
A simple liquid chromatography-tandem mass spectrometry method was validated to allow determination of zopiclone (ZOP), N-desmethylzopiclone (NDZOP), zopiclone N-oxide (ZOPNO) and 2-amino-5-chloropyridine (ACP) in urine at concentrations up to 3,000 ng/mL within 3.5 min. This method was used for quantitative analysis of the analytes in authentic urine samples obtained 10 h after oral administration of zopiclone (Imovane(®)) and in aliquots of the same urine samples after different storage conditions. In addition, pH of each studied urine sample was measured over time. The results showed that formation of ACP occurred at elevated pH and/or temperature by degradation of ZOP, NDZOP and ZOPNO. This method was also applied to samples obtained from two female victims of drug-facilitated assault. One sample had been exposed to long-term storage conditions at different temperatures and at pH >8.2, which resulted in high concentrations of ACP. The other sample, which was exposed to pH <6.5, showed no formation of ACP. ACP is formed both from ZOP and from its metabolites NDZOP and ZOPNO depending on the pH of the urine, time of storage and/or the temperature conditions. For correct interpretation in forensic cases, ZOP, its major metabolites and ACP should be analyzed. When ACP is identified in urine, the concentrations of ZOP, NDZOP and ZOPNO should be interpreted with great caution. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Terry, Ana L; Cogswell, Mary E; Wang, Chia-Yih; Chen, Te-Ching; Loria, Catherine M; Wright, Jacqueline D; Zhang, Xinli; Lacher, David A; Merritt, Robert K; Bowman, Barbara A
2016-01-01
Background: Twenty-four–hour urine sodium excretion is recommended for monitoring population sodium intake. Because of concerns about participation and completion, sodium excretion has not been collected previously in US nationally representative surveys. Objective: We assessed the feasibility of implementing 24-h urine collections as part of a nationally representative survey. Design: We selected a random half sample of nonpregnant US adults aged 20–69 y in 3 geographic locations of the 2013 NHANES. Participants received explicit instructions, started and ended the urine collection in a urine study mobile examination center, and answered questions about their collection. Among those with a complete 24-h urine collection, a random one-half were asked to collect a second 24-h urine sample. Sodium, potassium, chloride, and creatinine excretion were analyzed. Results: The final NHANES examination response rate for adults aged 20–69 y in these 3 study locations was 71%. Of those examined (n = 476), 282 (59%) were randomly selected to participate in the 24-h urine collection. Of these, 212 persons [75% of those selected for 24-h urine collection; 53% (equal to 71% × 75% of those selected for the NHANES)] collected a complete initial 24-h specimen and 92 persons (85% of 108 selected) collected a second complete 24-h urine sample. More men than women completed an initial collection (P = 0.04); otherwise, completion did not vary by sociodemographic characteristics, body mass index, education, or employment status for either collection. Mean 24-h urine volume and sodium excretion were 1964 ± 1228 mL and 3657 ± 2003 mg, respectively, for the first 24-h urine sample, and 2048 ± 1288 mL and 3773 ± 1891 mg, respectively, for the second collection. Conclusion: Given the 53% final component response rate and 75% completion rate, 24-h urine collections were deemed feasible and implemented in the NHANES 2014 on a subsample of adults aged 20–69 y to assess population sodium intake. This study was registered at clinicaltrials.gov as NCT02723682. PMID:27413136
Laube, Norbert; Zimmermann, Diana J
2004-01-01
This study was performed to quantify the effect of a 1-week freezer storage of urine on its calcium oxalate crystallization risk. Calcium oxalate is the most common urinary stone material observed in urolithiasis patients in western and affluent countries. The BONN-Risk-Index of calcium oxalate crystallization risk in human urine is determined from a crystallization experiment performed on untreated native urine samples. We tested the influence of a 1-week freezing on the BONN-Risk-Index value as well as the effect of the sample freezing on the urinary osmolality. In vitro crystallization experiments in 49 native urine samples from stone-forming and non-stone forming individuals were performed in order to determine their calcium oxalate crystallization risk according to the BONN-Risk-Index approach. Comparison of the results derived from original sample investigations with those obtained from the thawed aliquots by statistical evaluation shows that i) no significant deviation from linearity between both results exists and ii) both results are identical by statistical means. This is valid for both, the BONN-Risk-Index and the osmolality data. The differences in the BONN-Risk-Index results of both procedures of BONN-Risk-Index determination, however, exceed the clinically acceptable difference. Thus, determination of the urinary calcium oxalate crystallization risk from thawed urine samples cannot be recommended.
Khan, Latifa B; Read, Hannah M; Ritchie, Stephen R; Proft, Thomas
2017-01-01
Dipstick urinalysis is an informative, quick, cost-effective and non-invasive diagnostic tool that is useful in clinical practice for the diagnosis of urinary tract infections (UTIs), kidney diseases, and diabetes. We used dipstick urinalysis as a hands-on microbiology laboratory exercise to reinforce student learning about UTIs with a particular focus on cystitis, which is a common bacterial infection. To avoid exposure to potentially contaminated human urine samples, we prepared artificial urine using easily acquired and affordable ingredients, which allowed less-experienced students to perform urinalysis without the risk of exposure to pathogenic organisms and ensured reliable availability of the urine samples. This practical class taught medical students how to use urinalysis data in conjunction with medical history to diagnose diseases from urine samples and to determine a treatment plan for clinical scenarios.
Oliveira, Maria Isabel de; Namiyama, Gislene Mitsue; Cabral, Gabriela Bastos; Ferreira, João Leandro; Taniwaki, Noemi; Afonso, Ana Maria Sardinha; Lima, Isabella Rillo; Brigido, Luís Fernando Macedo de
2018-01-01
A great variety of viruses which cause exanthema share other clinical manifestations, making the etiologic identification a very difficult task, relying exclusively on the clinical examination. Rubella virus (RV) infection during the early stages of pregnancy can lead to serious birth defects, known as congenital rubella syndrome (CRS). In the present report, we described the presence of Zika virus (ZIKV) particles in urine samples and also ZIKV isolation in SIRC cells from the urine of a patient in acute phase of suspected rubella disease. The 50-year-old unvaccinated woman living in Sao Paulo, Brazil, was admitted to the emergency room with fever, headache, rash, arthralgia and prostration. Urine samples were collected for virus isolation and RT-qPCR. SIRC and Vero cells were inoculated with urine samples during 7 days. RT-qPCR was performed using measles virus (MV) and RV primers and both were found to be negative. After this result, RT-qPCR was performed for parvovirus B19, herpes virus 6 and ZIKV. The urine sample and the isolate were positive by Real Time PCR for ZIKV and negative for all other viruses tested. The sequences isolated are from the Asiatic lineage.
[The role of telomerase activity in non-invasive diagnostics of bladder cancer].
Glybochko, P V; Alyaev, J G; Potoldykova, N V; Polyakovsky, K A; Vinarov, A Z; Glukhov, A I; Gordeev, S A
2016-08-01
To evaluate the potentials of determining the telomerase activity (TA) in the cellular material of the urine for noninvasive diagnosis of bladder cancer (BC). Evaluation of TA was performed in the urine of 48 patients with bladder cancer (study group) before and after transurethral resection of the bladder wall (n=38), an open resection of the bladder (n=4), and cystectomy (n=6). TA was also evaluated in 48 tumor tissue samples obtained from these patients during removal of the bladder tumor. Each sample of the tumor tissue was separated into two parts, one of which was subjected to histological examination, and the latter was used to determine the telomerase activity. In all cases, the diagnosis of bladder cancer was confirmed morphologically. Determination of TA in the samples was performed by the modified TRAP-method (telomerase repeat amplification protocol), RT-PCR, PCR, and electrophoresis. As a control, cell material of the urine and tissue in 12 patients with chronic cystitis was investigated. TA before surgery was found in 45 (93.75%) of 48 samples of cellular material of the urine from patients with suspected bladder cancer. BC was histologically verified in all patients in this group. In the postoperative period, TA was not observed in the 48 samples of cellular material of the urine from patients with BC. In the control group of patients with histologically verified cystitis, weak TA was determined only in one sample of cellular material of the urine. The analysis indicates statistically significant predominance of patients with bladder cancer in case of TA in the urine (P=0.001). TA was detected in all samples of tumor tissue. We also analyzed the dependence of TA levels in urine and tissue on the degree of BC differentiation. In patients with highly differentiated BC, mean AT in the cellular materials of the urine was 0,61% (n=15), in patients with moderately differentiated BC - 0.95% (n=23), in patients with low-grade bladder cancer - 1.33% (n=10); in other words, increase in the TA levels with decreasing the degree of differentiation was observed. This finding can be used in the prognosis of the course of disease based on determining the TA level in these patients. Preliminary data indicate the possibility of use of determining the TA in cellular material of the urine for the diagnosis and monitoring of bladder cancer recurrence.
Kennedy, Mary Jayne; Griffin, Angela; Su, Ruifeng; Merchant, Michael; Klein, Jon
2011-01-01
Urinary proteomic profiling has potential to identify candidate biomarkers of renal injury in infants provided an adequate urine sample can be obtained. Although diapers are used to obtain urine for clinical evaluation, their use for proteomic analysis has not been investigated. We therefore performed feasibility studies on the use of diaper-extracted urine for 2-dimensional polyacrylamide gel electrophoresis (2D-PAGE). Pediatric waste urine (2–20 mL) was applied to gel-containing, non-gel and cotton-gauze diapers and then mechanically expressed. Urine volume and total protein were measured pre- and post-extraction. Proteins were separated via 2D-PAGE following application of urine (20–40 mL) to each matrix. 2D-PAGE was also performed on clinical specimens collected using each diaper type. Differences in the adsorption and retention of urine volume and protein were noted between matrices. Non-gel and cotton-gauze diapers provided the best protein/volume recovery and the lowest interference with the Bradford assay. 2D-PAGE was also successfully completed using urine samples from both cotton fiber matrices. Conversely, samples from low-gel diapers demonstrated poor protein separation and reproducibility. Diapers containing cotton-fiber matrices appear adequate for 2D-PAGE. Qualitative and quantitative analyses of resolved proteins using replicate, high resolution gels will be required, however, before diaper-extracted urine can be applied in proteomic profiling. PMID:21137001
NASA Astrophysics Data System (ADS)
Crevelin, Eduardo J.; Salami, Fernanda H.; Alves, Marcela N. R.; De Martinis, Bruno S.; Crotti, Antônio E. M.; Moraes, Luiz A. B.
2016-05-01
Amphetamine-type stimulants (ATS) are among illicit stimulant drugs that are most often used worldwide. A major challenge is to develop a fast and efficient methodology involving minimal sample preparation to analyze ATS in biological fluids. In this study, a urine pool solution containing amphetamine, methamphetamine, ephedrine, sibutramine, and fenfluramine at concentrations ranging from 0.5 pg/mL to 100 ng/mL was prepared and analyzed by atmospheric solids analysis probe tandem mass spectrometry (ASAP-MS/MS) and multiple reaction monitoring (MRM). A urine sample and saliva collected from a volunteer contributor (V1) were also analyzed. The limit of detection of the tested compounds ranged between 0.002 and 0.4 ng/mL in urine samples; the signal-to-noise ratio was 5. These results demonstrated that the ASAP-MS/MS methodology is applicable for the fast detection of ATS in urine samples with great sensitivity and specificity, without the need for cleanup, preconcentration, or chromatographic separation. Thus ASAP-MS/MS could potentially be used in clinical and forensic toxicology applications.
Workplace drug testing in Italy: findings about second-stage testing.
Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo
2015-03-01
Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.
The consequence of delayed fixation on subsequent preservation of urine cells.
Ahmed, Hussain G; Tom, Murtada Am
2011-01-01
Degenerative changes caused by delays in urine preservation contribute to false-negative and false-positive interpretation of urothelial disease in cytology. The aim of this study is to assess whether the delay of fixation of urine samples makes any significant difference to urine cytology and morphology, and the limit of acceptability of delay for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analyzing the preservation and degeneration of cells in urine samples. In this study, 50 voided urine specimens were taken at random from females complaining of vaginal discharge. Each specimen was divided into three sterile containers. The first was immediately centrifugated and the deposit was smeared onto a cleaned micro slide and immediately fixed into 95% ethyl alcohol for 15 minutes. The remaining two were prepared in the same manner, however, the second after two hours of collection and the third after four hours of collection. The degree of degeneration and thus the preservation were assessed by a table of chosen criteria, then ranked and analyzed using Friedman's nonparametric test, at p=0.05. The results showed a significant difference between the preservation and the delay in urine fixation, p<0.0001. Any delay in fixation of urine specimen for cytology affects the preservation of cells, which may result in miss diagnosis. It is recommended that urine samples for cytology should be fixed immediately after collection.
Berman, Elena S.F.; Fortsona, Susan L.; Snaith, Steven P.; Gupta, Manish; Baer, Douglas S.; Chery, Isabelle; Blanc, Stephane; Melanson, Edward L.; Thomson, Peter J; Speakman, John R.
2012-01-01
The stable isotopes of hydrogen (δ2H) and oxygen (δ18O) in human urine are measured during studies of total energy expenditure by the doubly labeled water method, measurement of total body water, and measurement of insulin resistance by glucose disposal among other applications. An ultrasensitive laser absorption spectrometer based on off-axis integrated cavity output spectroscopy was demonstrated for simple and inexpensive measurement of stable isotopes in natural isotopic abundance and isotopically enriched human urine. Preparation of urine for analysis was simple and rapid (approx. 25 samples per hour), requiring no decolorizing or distillation steps. Analysis schemes were demonstrated to address sample-to-sample memory while still allowing analysis of 45 natural or 30 enriched urine samples per day. The instrument was linear over a wide range of water isotopes (δ2H = −454 to +1702 ‰ and δ18O= −58.3 to +265 ‰). Measurements of human urine were precise to better than 0.65 ‰ 1σ for δ2H and 0.09 ‰ 1σ for δ18O for natural urines, 1.1 ‰ 1σ for δ2H and 0.13 ‰ 1σ for δ18O for low enriched urines, and 1.0 ‰ 1σ for δ2H and 0.08 ‰ 1σ for δ18O for high enriched urines. Furthermore, the accuracy of the isotope measurements of human urines was verified to better than ±0.81 ‰ in δ2H and ±0.13 ‰ in δ18O (average deviation) against three independent IRMS laboratories. The ability to immediately and inexpensively measure the stable isotopes of water in human urine is expected to increase the number and variety of experiments which can be undertaken. PMID:23075099
Pathak, Neha; Dodds, Julie; Khan, Khalid
2014-01-01
Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064
Born, M; Axmann, C; Kader, R; von Falkenhausen, M; Manka, C; Willinek, W A; Schild, H
2004-11-01
Renal excretion of orally or rectally applied Gastrografin is reported to be a reliable indicator of a perforation or a postoperative anastomotic dehiscence of the GI-tract. The study was conducted to determine whether increased attenuation of the urine measured by CT after oral or rectal application of Gastrografin can give reliable evidence of any leakage from the gastrointestinal tract. Urine samples of 33 patients, who underwent a Gastrografin-enhanced fluoroscopic examination of the esophagus or the GI-tract for different clinical reasons, were examined by CT. The samples had been taken immediately before and 60 to 90 minutes after application of 100 ml Gastrografin. The results were compared with those of 5 healthy volunteers, who took urine samples before, 30, 60, 90, and 120 minutes after drinking 100 ml of Gastrografin. Maximal attenuation of the volunteers' urine samples was achieved 60 to 90 minutes after Gastrografin application with a mean of 50 Hounsfield units (HU), SD = 17 HU. The urine of three patients with radiologically proven fistula or dehiscence of a GI-tract anastomosis had no relevant increase in attenuation. Three other cases without any clinical or radiological evidence of an anastomotic leak had a substantial increase in the attenuation of the urine probes (87, 110, and 290 HU, respectively). The CT-measured urine samples as evidence of renal excretion of orally or rectally applied Gastrografin are not reliable for the detection of leaks from the GI-tract.
Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof
2015-04-01
Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.
Vu, N T; Chaturvedi, A K; Canfield, D V
1999-05-31
Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender, starting sample volume, or concentration method. Preservation by 0.25% sodium azide was acceptable for sample storage at 4 degrees C during a period of 30 days. For longer storage duration, freezing at -70 degrees C may be more appropriate. Thus, the applicability of the DQA1 + PM typing was clearly demonstrated for individualization of urine samples.
Sakhi, Amrit Kaur; Sabaredzovic, Azemira; Cequier, Enrique; Thomsen, Cathrine
2017-12-01
Exposure to phthalates has been associated with reproductive and developmental toxicity. Data on levels of these compounds in the Norwegian population is limited. In this study, urine samples were collected from 48 mothers and their children in two counties in Norway. Eleven different phthalate metabolites originating from six commonly used phthalates in consumer products were determined. Concentrations of phthalate metabolites were significantly higher in children compared to mothers except for mono-ethyl phthalate (MEP). The mothers provided several urine samples during 24hours (h) and diurnal variation showed that the concentrations in the morning urine samples (24-8h) were significantly higher than at other time-periods for most of the phthalate metabolites. Intraclass correlation coefficients (ICCs) for 24-hour time-period were in the range of 0.49-0.81. These moderate to high ICCs indicate that one spot urine sample can be used to estimate the exposure to phthalates. Since a significant effect of time of day was observed, it is still advisable to standardize the collection time point to reduce the variation. For the mothers, the use of personal care products (PCPs) were less associated with morning urine samples than early day (8-12h) and evening (16-24h) urine samples. The use of perfume and hair products were positively associated with the urinary concentrations of low molecular weight phthalates. Use of shower soap and shampoo were positively associated with urinary concentration of di(2-ethylhexyl) phthalate (DEHP) metabolites. For children, face cream use was positively associated with phthalate metabolites in the morning samples, and hand soap use was negatively associated with concentration of urinary DEHP metabolites in afternoon/evening samples. Since different PCPs were associated with the urinary phthalate metabolites in different time-periods during a day, more than one spot urine sample might be required to study associations between urinary phthalate metabolites and the use of PCPs. Copyright © 2017 Elsevier B.V. All rights reserved.
Coca tea consumption causes positive urine cocaine assay.
Mazor, Suzan S; Mycyk, Mark B; Wills, Brandon K; Brace, Larry D; Gussow, Leon; Erickson, Timothy
2006-12-01
Coca tea, derived from the same plant that is used to synthesize cocaine, is commonly consumed in South America and easily obtained in the United States. To determine whether consumption of coca tea would result in a positive urine toxicology screen for cocaine metabolites. Five healthy adult volunteers consumed coca tea and underwent serial quantitative urine testing for cocaine metabolites by fluorescence polarization immunoassay. The cutoff for a positive assay was chosen at 300 ng/ml, the National Institute on Drug Abuse standard. Each participant's urine cocaine assay was positive (level exceeding 300 ng/ml) by 2 h after ingestion. Three out of five participants' samples remained positive at 36 h. Mean urine benzoylecgonine concentrations in all postconsumption samples was 1777 ng/ml (95% confidence interval: 1060-2495). Coca tea ingestion resulted in a positive urine assay for cocaine metabolite. Healthcare professionals should consider a history of coca tea ingestion when interpreting urine toxicology results.
NASA Astrophysics Data System (ADS)
Huang, Shaohua; Wang, Lan; Chen, Weisheng; Feng, Shangyuan; Lin, Juqiang; Huang, Zufang; Chen, Guannan; Li, Buhong; Chen, Rong
2014-11-01
Non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy (SERS) analysis was presented. Urine SERS spectra were measured on esophagus cancer patients (n = 56) and healthy volunteers (n = 36) for control analysis. Tentative assignments of the urine SERS spectra indicated some interesting esophagus cancer-specific biomolecular changes, including a decrease in the relative content of urea and an increase in the percentage of uric acid in the urine of esophagus cancer patients compared to that of healthy subjects. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was employed to analyze and differentiate the SERS spectra between normal and esophagus cancer urine. The diagnostic algorithms utilizing a multivariate analysis method achieved a diagnostic sensitivity of 89.3% and specificity of 83.3% for separating esophagus cancer samples from normal urine samples. These results from the explorative work suggested that silver nano particle-based urine SERS analysis coupled with PCA-LDA multivariate analysis has potential for non-invasive detection of esophagus cancer.
Ultrasonic-based membrane aided sample preparation of urine proteomes.
Jesus, Jemmyson Romário; Santos, Hugo M; López-Fernández, H; Lodeiro, Carlos; Arruda, Marco Aurélio Zezzi; Capelo, J L
2018-02-01
A new ultrafast ultrasonic-based method for shotgun proteomics as well as label-free protein quantification in urine samples is developed. The method first separates the urine proteins using nitrocellulose-based membranes and then proteins are in-membrane digested using trypsin. The enzymatic digestion process is accelerated from overnight to four minutes using a sonoreactor ultrasonic device. Overall, the sample treatment pipeline comprising protein separation, digestion and identification is done in just 3h. The process is assessed using urine of healthy volunteers. The method shows that male can be differentiated from female using the protein content of urine in a fast, easy and straightforward way. 232 and 226 proteins are identified in urine of male and female, respectively. From this, 162 are common to both genders, whilst 70 are unique to male and 64 to female. From the 162 common proteins, 13 are present at levels statistically different (p < 0.05). The method matches the analytical minimalism concept as outlined by Halls, as each stage of this analysis is evaluated to minimize the time, cost, sample requirement, reagent consumption, energy requirements and production of waste products. Copyright © 2017 Elsevier B.V. All rights reserved.
Doggui, Radhouene; El Ati-Hellal, Myriam; Traissac, Pierre; El Ati, Jalila
2018-03-26
Urinary iodine concentration (UIC) is commonly used to assess iodine status of subjects in epidemiological surveys. As pre-analytical factors are an important source of measurement error and studies about this phase are scarce, our objective was to assess the influence of urine sampling conditions on UIC, i.e., whether the child ate breakfast or not, urine void rank of the day, and time span between last meal and urine collection. A nationwide, two-stage, stratified, cross-sectional study including 1560 children (6-12 years) was performed in 2012. UIC was determined by the Sandell-Kolthoff method. Pre-analytical factors were assessed from children's mothers by using a questionnaire. Association between iodine status and pre-analytical factors were adjusted for one another and socio-economic characteristics by multivariate linear and multinomial regression models (RPR: relative prevalence ratios). Skipping breakfast prior to morning urine sampling decreased UIC by 40 to 50 μg/L and the proportion of UIC < 100 μg/L was higher among children having those skipped breakfast (RPR = 3.2[1.0-10.4]). In unadjusted analyses, UIC was less among children sampled more than 5 h from their last meal. UIC decreased with rank of urine void (e.g., first vs. second, P < 0.001); also, the proportion of UIC < 100 μg/L was greater among 4th rank samples (vs. second RPR = 2.1[1.1-4.0]). Subjects' breakfast status and urine void rank should be accounted for when assessing iodine status. Providing recommendations to standardize pre-analytical factors is a key step toward improving accuracy and comparability of survey results for assessing iodine status from spot urine samples. These recommendations have to be evaluated by future research.
Curl, Cynthia L; Fenske, Richard A; Kissel, John C; Shirai, Jeffry H; Moate, Thomas F; Griffith, William; Coronado, Gloria; Thompson, Beti
2002-01-01
We analyzed organophosphorus pesticide exposure in 218 farm worker households in agricultural communities in Washington State to investigate the take-home pathway of pesticide exposure and to establish baseline exposure levels for a community intervention project. House dust samples (n = 156) were collected from within the homes, and vehicle dust samples (n = 190) were collected from the vehicles used by the farm workers to commute to and from work. Urine samples were obtained from a farm worker (n = 213) and a young child (n = 211) in each household. Dust samples were analyzed for six pesticides, and urine samples were analyzed for five dialkylphosphate (DAP) metabolites. Azinphosmethyl was detected in higher concentrations (p < 0.0001) than the other pesticides: geometric mean concentrations of azinphosmethyl were 0.53 micro g/g in house dust and 0.75 micro g/g in vehicle dust. Dimethyl DAP metabolite concentrations were higher than diethyl DAP metabolite concentrations in both child and adult urine (p < 0.0001). Geometric mean dimethyl DAP concentrations were 0.13 micro mol/L in adult urine and 0.09 micro mol/L in child urine. Creatinine-adjusted geometric mean dimethyl DAP concentrations were 0.09 micro mol/g in adult urine and 0.14 micro mol/g in child urine. Azinphosmethyl concentrations in house dust and vehicle dust from the same household were significantly associated (r2 = 0.41, p < 0.0001). Dimethyl DAP levels in child and adult urine from the same household were also significantly associated (r2 = 0.18, p < 0.0001), and this association remained when the values were creatinine adjusted. The results of this work support the hypothesis that the take-home exposure pathway contributes to residential pesticide contamination in agricultural homes where young children are present. PMID:12460819
Lauridsen, Michael; Hansen, Steen H; Jaroszewski, Jerzy W; Cornett, Claus
2007-02-01
Metabonomic approaches are believed to have the capability of revolutionizing diagnosis of diseases and assessment of patient conditions after medical interventions. In order to ensure comparability of metabonomic 1H NMR data from different studies, we suggest validated sample preparation guidelines for human urine based on a stability study that evaluates effects of storage time and temperature, freeze-drying, and the presence of preservatives. The results indicated that human urine samples should be stored at or below -25 degrees C, as no changes in the 1H NMR fingerprints have been observed during storage at this temperature for 26 weeks. Formation of acetate, presumably due to microbial contamination, was occasionally observed in samples stored at 4 degrees C without addition of a preservative. Addition of a preserving agent is not mandatory provided that the samples are stored at -25 degrees C. Thus, no differences were observed between 1H NMR spectra of nonpreserved urines and urines with added sodium azide and stored at -25 degrees C, whereas the presence of sodium fluoride caused a shift of especially citrate resonances. Freeze-drying of urine and reconstitution in D2O at pH 7.4 resulted in the disappearance of the creatinine CH2 signal at delta 4.06 due to deuteration. A study evaluating the effects of phosphate buffer concentration on signal variability and assessment of the probability of citrate or creatinine resonances crossing bucket border (a boundary between adjacent integrated regions) led to the conclusion that a minimum buffer concentration of 0.3 M is adequate for normal urines used in this study. However, final buffer concentration of 1 M will be required for very concentrated urines.
NASA Technical Reports Server (NTRS)
Feedback, Daniel L.; Cibuzar, Branelle R.
2009-01-01
The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.
Excreta Sampling as an Alternative to In Vivo Measurements at the Hanford Site.
Carbaugh, Eugene H; Antonio, Cheryl L; Lynch, Timothy P
2015-08-01
The capabilities of indirect radiobioassay by urine and fecal sample analysis were compared with the direct radiobioassay methods of whole body counting and lung counting for the most common radionuclides and inhalation exposure scenarios encountered by Hanford workers. Radionuclides addressed by in vivo measurement included 137Cs, 60Co, 154Eu, and 241Am as an indicator for plutonium mixtures. The same radionuclides were addressed using gamma energy analysis of urine samples, augmented by radiochemistry and alpha spectrometry methods for plutonium in urine and fecal samples. It was concluded that in vivo whole body counting and lung counting capability should be maintained at the Hanford Site for the foreseeable future, however, urine and fecal sample analysis could provide adequate, though degraded, monitoring capability for workers as a short-term alternative, should in vivo capability be lost due to planned or unplanned circumstances.
NASA Astrophysics Data System (ADS)
Ahmed, Hytham M.; Ebeid, Wael B.
2015-05-01
Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200 ng/ml respectively and recovery was >98% (n = 5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000 IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period.
Urine sampling and collection system optimization and testing
NASA Technical Reports Server (NTRS)
Fogal, G. L.; Geating, J. A.; Koesterer, M. G.
1975-01-01
A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.
Pilot-Plant Demonstration of Wet Oxidation for Treatment of Shipboard Wastewaters.
1975-11-01
minus mg of COD removed in prior sampling )] Table I indicates that, when the reactor was last sampled after six injections Pf concentrated feces and urine ...oxidation of feces and urine is of an inorganic nature. The pH of most of the samples taken in thes tests was measured using indi- cator papers. All...BATCH EXPERIMENTS ON FECES AND URINE IN rRESENCE OF BARBER-COLMAN CO. CATALYST 10,480 ............. . E.1 lest Procedure ......... . E-3 E.2 Test
A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.
Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R
2017-07-01
The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.
S Herath, H M Ayala; Kawakami, Tomonori; Nagasawa, Shiori; Serikawa, Yuka; Motoyama, Ayuri; Chaminda, G G Tushara; Weragoda, S K; Yatigammana, S K; Amarasooriya, A A G D
2018-04-01
Chronic kidney disease of unknown etiology (CKDu) is spreading gradually in Sri Lanka. In the current research, 1,435 well water samples from all 25 districts of Sri Lanka, 91 rice samples, and 84 human urine samples from both CKDu-endemic and non-endemic areas in Sri Lanka were analyzed for arsenic, cadmium, lead, and chromium to detect whether toxic elements could be a cause of CKDu. The liver-type fatty acid binding protein (L-FABP) concentration and arsenic, cadmium, lead, and chromium concentrations of the urine samples were analyzed to determine the relation of L-FABP with arsenic, cadmium, lead, and chromium. High concentrations of arsenic, cadmium, lead, and chromium were not detected in the well water samples from CKDu-endemic areas. Arsenic, cadmium, and lead contents in the rice samples from both CKDu-endemic and non-endemic areas were well below the Codex standard. There were no relationships between the L-FABP concentration and concentrations of arsenic, cadmium, lead, and chromium in urine. In addition, arsenic, cadmium, lead, and chromium concentrations in human urine samples from CKDu-endemic areas were not significantly different from those from non-endemic areas. These findings indicated that arsenic, cadmium, lead, and chromium could not cause CKDu.
Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S
2015-09-01
The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.
Urine chromium as an estimator of air exposure to stainless steel welding fumes.
Sjögren, B; Hedström, L; Ulfvarson, U
1983-01-01
Welding stainless steel with covered electrodes, also called manual metal arc welding, generates hexavalent airborne chromium. Chromium concentrations in air and post-shift urine samples, collected the same arbitrarily chosen working day, showed a linear relationship. Since post-shift urine samples reflect chromium concentrations of both current and previous stainless steel welding fume exposure, individual urine measurements are suggested as approximate although not exact estimators of current exposure. This study evaluates the practical importance of such measurements by means of confidence limits and tests of validity.
Fernández, María del Mar Ramírez; Wille, Sarah M R; Samyn, Nele; Wood, Michelle; López-Rivadulla, Manuel; De Boeck, Gert
2009-01-01
An automated online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of amphetamines in blood and urine was developed and validated. Chromatographic separation was achieved on a Nucleodur Sphinx RP column with an LC gradient (a mixture of 10 mM ammonium formate buffer and acetonitrile), ensuring the elution of amphetamine, methamphetamine, MDMA, MDA, MDEA, PMA, and ephedrine within 11 min. The method was fully validated, according to international guidelines, using only 100 and 50 microL of blood and urine, respectively. The method showed an excellent intra- and interassay precision (relative standard deviation < 11.2% and bias < 13%) for two external quality control samples (QC) for both matrices and three and two 'in house' QCs for blood and urine, respectively. Responses were linear over the investigated range (r(2) > 0.99, 2.5-400 microg/L for blood and 25-1000 microg/L for urine). Limits of quantification were determined to be 2.5 and 25 microg/L for blood and urine, respectively. Limits of detection ranged from 0.05 to 0.5 microg/L for blood and 0.25 to 2.5 microg/L for urine, depending on the compound. Furthermore, the analytes and the processed samples were demonstrated to be stable (in the autosampler for at least 72 h and after three freeze/thaw cycles), and no disturbing matrix effects were observed for all compounds. Moreover, no carryover was observed after the analysis of high concentration samples (15,000 microg/L). The method was subsequently applied to authentic blood and urine samples obtained from forensic cases, which covered a broad range of concentrations. The validation results and actual sample analyses demonstrated that this method is rugged, precise, accurate, and well-suited for routine analysis as more than 72 samples are analyzed non-stop in 24 h with minimum sample handling. The combination of the high-throughput online SPE and the well-known sensitivity and selectivity assured by MS-MS resulted in the elimination of the bottleneck associated with the sample preparation requirements and provided increased sensitivity, accuracy, and precision.
Fluoride in drinking water and human urine in Southern Haryana, India.
Singh, Bhupinder; Gaur, Shalini; Garg, V K
2007-06-01
The objective of this study was to determine the fluoride content in drinking water and urine samples of adolescent males aged 11-16 years living in Southern Haryana, India. A total of 30 drinking water sources in the studied habitations were assessed for fluoride contamination. Fluoride was estimated in the urine of 400 male children randomly selected from these habitations. The fluoride concentration in drinking water and urine samples was determined using USEPA fluoride ion selective electrode method. The mean fluoride concentration in drinking water samples of Pataudi, Haily Mandi and Harsaru villages was 1.68+/-0.35, 3.22+/-1.18 and 1.78+/-0.12 mg/l, respectively. The mean urinary fluoride concentration was 2.26+/-0.024 mg/l at Pataudi, 2.48+/-0.77 mg/l at Haily Mandi and 2.43+/-0.84 mg/l at Harsaru village. The higher fluoride levels in the urine of children may be associated to higher fluoride levels in drinking water. The accuracy of measurements was assessed with known addition method in water and urine. Mean fluoride recovery was 98.0 and 99.1% in water and urine. The levels obtained were reproducible with in +/-3% error limit.
Presence of infective Epstein-Barr virus in the urine of patients with infectious mononucleosis.
Landau, Z; Gross, R; Sanilevich, A; Friedmann, A; Mitrani-Rosenbaum, S
1994-11-01
The presence of Epstein-Barr virus (EBV) in the blood and urine of 20 patients with infectious mononucleosis (IM) was investigated together with the clinical course of the disease, and in 9 patients up to 2-7 months after recovery. EBV DNA, analyzed by the polymerase chain reaction (PCR), was detected in the blood of all 20 patients from the first sample obtained and detected between 3 to 42 days from the beginning of symptoms and up to 2-3 months after recovery. In the urine, EBV DNA was detected in 15 out of 16 (93%) patients in the first sample obtained and detected between 3 to 50 days during the clinical course of the disease. In four patients EBV DNA was detected in the urine up to 3 months after full recovery. Seventeen out of 26 (65%) urine samples including 3 which were obtained 2-7 months after recovery infected B cells as assessed by PCR. Nine out of 12 (75%) urine samples tested induced Epstein-Barr nuclear antigen (EBNA) in the infected B-cell line. In addition to the persistence of EBV in the blood of IM patients, these studies show for the first time the presence of infective EBV in the urine during the clinical course of the disease and up to 7 months after full clinical recovery.
[Assessment of dietary intake and urinary excretion of sodium and potassium in adults].
Cornejo, Karen; Pizarro, Fernando; Atalah, Eduardo; Galgani, José E
2014-06-01
Hypertension is associated with elevated sodium and low potassium intakes. The determination of sodium and potassium intake by dietary records is inaccurate, being its measurement from 24-h urine collection the reference method. To determine urinary sodium and potassium excretion in adults. To compare dietary sodium and potassium intake and their excretion from an isolated urine sample against the reference method. Seventy healthy adults aged 35 ± 8 years with a body mass index 25 ± 2 kg/m² (36 women) were studied. Urine was collected over 24 h, including an isolated urine sample taken in fasting conditions. Additionally, three 24-h dietary records were performed. Reported sodium and potassium intake was 2,720 ± 567 and 1,068 ± 433 mg/day, respectively. In turn, urinary excretion of sodium and potassium was 4,770 ± 1,532 and 1,852 ± 559 mg/day, respectively. These latter values were significantly higher than those obtained by dietary records. Furthermore, the urinary sodium and potassium excretion estimated from an isolated urine sample was 4,839 ± 1,355 and 1,845 ± 494 mg/day, respectively. These values were similar to those obtained with a 24 h urine collection. Dietary records underestimated electrolyte intake when compared with the reference method. Using an isolated urine sample to estimate electrolyte intake may be a reliable alternative.
NASA Technical Reports Server (NTRS)
Kelbaugh, B. N.; Picciolo, G. L.; Chappelle, E. W.; Colburn, M. E. (Inventor)
1973-01-01
An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.
High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.
Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna
2013-01-01
Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.
Value of Routine Dengue Diagnostic Tests in Urine and Saliva Specimens
Andries, Anne-Claire; Duong, Veasna; Ly, Sowath; Cappelle, Julien; Kim, Kim Srorn; Lorn Try, Patrich; Ros, Sopheaktra; Ong, Sivuth; Huy, Rekol; Horwood, Paul; Flamand, Marie; Sakuntabhai, Anavaj; Tarantola, Arnaud; Buchy, Philippe
2015-01-01
Background Dengue laboratory diagnosis is essentially based on detection of the virus, its components or antibodies directed against the virus in blood samples. Blood, however, may be difficult to draw in some patients, especially in children, and sampling during outbreak investigations or epidemiological studies may face logistical challenges or limited compliance to invasive procedures from subjects. The aim of this study was to assess the possibility of using saliva and urine samples instead of blood for dengue diagnosis. Methodology/Principal Findings Serial plasma, urine and saliva samples were collected at several time-points between the day of admission to hospital until three months after the onset of fever in children with confirmed dengue disease. Quantitative RT-PCR, NS1 antigen capture and ELISA serology for anti-DENV antibody (IgG, IgM and IgA) detection were performed in parallel on the three body fluids. RT-PCR and NS1 tests demonstrated an overall sensitivity of 85.4%/63.4%, 41.6%/14.5% and 39%/28.3%, in plasma, urine and saliva specimens, respectively. When urine and saliva samples were collected at the same time-points and tested concurrently, the diagnostic sensitivity of RNA and NS1 detection assays was 69.1% and 34.4%, respectively. IgG/IgA detection assays had an overall sensitivity of 54.4%/37.4%, 38.5%/26.8% and 52.9%/28.6% in plasma, urine and saliva specimens, respectively. IgM were detected in 38.1% and 36% of the plasma and saliva samples but never in urine. Conclusions Although the performances of the different diagnostic methods were not as good in saliva and urine as in plasma specimens, the results obtained by qRT-PCR and by anti-DENV antibody ELISA could well justify the use of these two body fluids to detect dengue infection in situations when the collection of blood specimens is not possible. PMID:26406240
Butler, Christopher C; Sterne, Jonathan Ac; Lawton, Michael; O'Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D
2016-07-01
The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Acutely unwell children <5 years presenting to 233 UK primary care sites. Logistic regression to identify independent associations of symptoms, signs, and urine dipstick test results with UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Nappy pad samples were obtained from 3205 children (82% aged <2 years; 48% female), culture results were available for 2277 (71.0%) and 30 (1.3%) had a UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs' 'working diagnosis' had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were 'frankly contaminated' (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. © British Journal of General Practice 2016.
Doping control study of AICAR in post-race urine and plasma samples from horses.
Wong, Jenny K Y; Kwok, Wai Him; Chan, George H M; Choi, Timmy L S; Ho, Emmie N M; Jaubert, Murielle; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Cawley, Adam; Ming Williams, H; Keledjian, John; Brooks, Lydia; Chambers, Adam; Lin, Yuanyuan; Wan, Terence S M
2017-09-01
Acadesine, 5-aminoimidazole-4-carboxamide-1-β-D-ribofuranoside, commonly known as AICAR, is a naturally occurring adenosine monophosphate-activated protein kinase (AMPK) activator in many mammals, including humans and horses. AICAR has attracted considerable attention recently in the field of doping control because of a study showing the enhancement of endurance performance in unexercised or untrained mice, resulting in the term 'exercise pill'. Its use has been classified as gene doping by the World Anti-Doping Agency (WADA), and since it is endogenous, it may only be possible to control deliberate administration of AICAR to racehorses after establishment of an appropriate threshold. Herein we report our studies of AICAR in post-race equine urine and plasma samples including statistical studies of AICAR concentrations determined from 1,470 urine samples collected from thoroughbreds and standardbreds and analyzed in Australia, France, and Hong Kong. Quantification methods in equine urine and plasma using liquid chromatography-mass spectrometry were developed by the laboratories in each country. An exchange of spiked urine and plasma samples between the three countries was conducted, confirming no significant differences in the methods. However, the concentration of AICAR in plasma was found to increase upon haemolysis of whole blood samples, impeding the establishment of a suitable threshold in equine plasma. A possible urine screening cut-off at 600 ng/mL for the control of AICAR in racehorses could be considered for adoption. Application of the proposed screening cut-off to urine samples collected after intravenous administration of a small dose (2 g) of AICAR to a mare yielded a short detection time of approximately 4.5 h. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Butler, Christopher C; Sterne, Jonathan AC; Lawton, Michael; O’Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D
2016-01-01
Background The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. Aim To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Design and setting Acutely unwell children <5 years presenting to 233 UK primary care sites. Method Logistic regression to identify independent associations of symptoms, signs, and urine dipstick test results with UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Results Nappy pad samples were obtained from 3205 children (82% aged <2 years; 48% female), culture results were available for 2277 (71.0%) and 30 (1.3%) had a UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs’ ‘working diagnosis’ had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were ‘frankly contaminated’ (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Conclusion Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. PMID:27364678
De, Prithwiraj; Amin, Anita G.; Valli, Eloise; Perkins, Mark D.; McNeil, Michael; Chatterjee, Delphi
2015-01-01
Globally, tuberculosis is slowly declining each year and it is estimated that 37 million lives were saved between 2000 and 2013 through effective diagnosis and treatment. Currently, diagnosis relies on demonstration of the bacteria, Mycobacterium tuberculosis (Mtb), in clinical specimens by serial sputum microscopy, culture and molecular testing. Commercial immunoassay lateral flow kits developed to detect Mtb lipoglycan lipoarabinomannan (LAM) in urine as a marker of active TB exhibit poor sensitivity, especially in immunocompetent individuals, perhaps due to low abundance of the analyte. Our present study was designed to develop methods to validate the presence of LAM in a quantitative fashion in human urine samples obtained from culture-confirmed TB patients. Herein we describe, a consolidated approach for isolating LAM from the urine and quantifying D-arabinose as a proxy for LAM, using Gas Chromatography/Mass Spectrometry. 298 urine samples obtained from a repository were rigorously analyzed and shown to contain varying amounts of LAM-equivalent ranging between ~10–40 ng/mL. To further substantiate that D-arabinose detected in the samples originated from LAM, tuberculostearic acid, the unique 10-methyloctadecanoic acid present at the phosphatidylinositol end of LAM was also analyzed in a set of samples and found to be present confirming that the D-arabinose was indeed derived from LAM. Among the 144 samples from culture-negative TB suspects, 30 showed presence of D-arabinose suggesting another source of the analyte, such as disseminated TB or from non-tuberculosis mycobacterium. Our work validates that LAM is present in the urine samples of culture-positive patients in small but readily detectable amounts. The study further substantiates LAM in urine as a powerful biomarker for active tuberculosis. PMID:26633829
A population study of urine glycerol concentrations in elite athletes competing in North America.
Kelly, Brian N; Madsen, Myke; Sharpe, Ken; Nair, Vinod; Eichner, Daniel
2013-01-01
Glycerol is an endogenous substance that is on the World Anti-Doping Agency's list of prohibited threshold substances due to its potential use as a plasma volume expansion agent. The WADA has set the threshold for urine glycerol, including measurement uncertainty, at 1.3 mg/mL. Glycerol in circulation largely comes from metabolism of triglycerides in order to meet energy requirements and when the renal threshold is eclipsed, glycerol is excreted into urine. In part due to ethnic differences in postprandial triglyceride concentrations, we investigated urine glycerol concentrations in a population of elite athletes competing in North America and compared the results to those of athletes competing in Europe. 959 urine samples from elite athletes competing in North America collected for anti-doping purposes were analyzed for urine glycerol concentrations by a gas chromatography mass-spectrometry method. Samples were divided into groups according to: Timing (in- or out-of-competition), Class (strength, game, or endurance sports) and Gender. 333 (34.7%) samples had undetectable amounts of glycerol (<1 μg/mL). 861 (89.8%) of the samples had glycerol concentrations ≤20 μg/mL. The highest glycerol concentration observed was 652 μg/mL. Analysis of the data finds the effects of each category to be statistically significant. The largest estimate of the 99.9(th) percentile, from the in-competition, female, strength athlete samples, was 1813 μg/mL with a 95% confidence range from 774 to 4251 μg/mL. This suggests a conservative threshold of 4.3 mg/mL, which would result in a reasonable detection window for urine samples collected in-competition for all genders and sport classes. Copyright © 2013 John Wiley & Sons, Ltd.
Mutagenicity of urine from individuals exposed to LPG combustion products.
Yin, X J; Liu, J Z; Kong, X H; Chu, J H; Wang, H; Xiao, Z X
1998-09-01
The mutagenicity of urine from individuals exposed to the combustion products of liquefied petroleum gas (LPG) was detected with Salmonella typhimurium TA98 and its newly developed derivatives YG1021 (nitroreductase overproducing) and YG1024 (O-acetyltransferase overproducing). The detection showed significantly increased mutagenicity for the two YG strains and increased positive rates for all three strains in the presence of both rat liver S9 and beta-glucuronidase. Further analysis demonstrated that urine samples taken from smoking and non-smoking exposed individuals exhibited significantly higher mutagenic potency (revertants/10 microliters urine concentrate) than their corresponding controls. These results indicate that the increased urine mutagenicity is caused by the exposure to LPG combustion products or smoking. The mutagenic potency of urine samples of all exposed individuals tested with YG1024 was found to be about 7 times higher than with TA98. The difference in mutagenic potency was smaller for the same samples when comparison was made between YG1021 and TA98. This suggests that the mutagenic compounds present in the urine samples contain mainly aromatic compounds as glucuronide conjugates. Our results demonstrate that YG1024 is more sensitive than TA98 in detecting the mutagenicity of these samples. In addition, no significant difference in the mutagenic potency between the 'pure' exposed (non-smokers') and the 'pure' smokers' (unexposed) samples was found in all three tester strains. This might mean that the exposure extent of mutagens/carcinogens in LPG combustion products for exposed individuals roughly corresponds to the smoking level of smokers who smoke 20-40 cigarettes per day. Furthermore, the results also suggest that synergism might exist in the mutagenic effects of exposure to LPG combustion products and cigarette smoking.
Introduction of sample tubes with sodium azide as a preservative for ethyl glucuronide in urine.
Luginbühl, Marc; Weinmann, Wolfgang; Al-Ahmad, Ali
2017-09-01
Ethyl glucuronide (EtG) is a direct alcohol marker, which is widely used for clinical and forensic applications, mainly for abstinence control. However, the instability of EtG in urine against bacterial degradation or the post-collectional synthesis of EtG in contaminated samples may cause false interpretation of EtG results in urine samples. This study evaluates the potential of sodium azide in tubes used for urine collection to hinder degradation of ethyl glucuronide by bacterial metabolism taking place during growth of bacterial colonies. The tubes are part of a commercial oral fluid collection device. The sampling system was tested with different gram-positive and gram-negative bacterial species previously observed in urinary tract infections, such as Escherichia coli, Staphylococcus aureus, Enterecoccus faecalis, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomonas aeruginosa. Inhibition of bacterial growth by sodium azide, resulting in lower numbers of colony forming units compared to control samples, was observed for all tested bacterial species. To test the prevention of EtG degradation by the predominant pathogen in urinary tract infection, sterile-filtered urine and deficient medium were spiked with EtG, and inoculated with E. coli prior to incubation for 4 days at 37 °C in tubes with and without sodium azide. Samples were collected every 24 hours, during four consecutive days, whereby the colony forming units (CFU) were counted on Columbia blood agar plates, and EtG was analyzed by LC-MS/MS. As expected, EtG degradation was observed when standard polypropylene tubes were used for the storage of contaminated samples. However, urine specimens collected in sodium azide tubes showed no or very limited bacterial growth and no EtG degradation. As a conclusion, sodium azide is useful to reduce bacterial growth of gram-negative and gram-positive bacteria. It inhibits the degradation of EtG by E. coli and can be used for the stabilization of EtG in urine samples.
Rapid determination of 226Ra in emergency urine samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.
2014-02-27
A new method has been developed at the Savannah River National Laboratory (SRNL) that can be used for the rapid determination of 226Ra in emergency urine samples following a radiological incident. If a radiological dispersive device event or a nuclear accident occurs, there will be an urgent need for rapid analyses of radionuclides in urine samples to ensure the safety of the public. Large numbers of urine samples will have to be analyzed very quickly. This new SRNL method was applied to 100 mL urine aliquots, however this method can be applied to smaller or larger sample aliquots as needed.more » The method was optimized for rapid turnaround times; urine samples may be prepared for counting in <3 h. A rapid calcium phosphate precipitation method was used to pre-concentrate 226Ra from the urine sample matrix, followed by removal of calcium by cation exchange separation. A stacked elution method using DGA Resin was used to purify the 226Ra during the cation exchange elution step. This approach combines the cation resin elution step with the simultaneous purification of 226Ra with DGA Resin, saving time. 133Ba was used instead of 225Ra as tracer to allow immediate counting; however, 225Ra can still be used as an option. The rapid purification of 226Ra to remove interferences using DGA Resin was compared with a slightly longer Ln Resin approach. A final barium sulfate micro-precipitation step was used with isopropanol present to reduce solubility; producing alpha spectrometry sources with peaks typically <40 keV FWHM (full width half max). This new rapid method is fast, has very high tracer yield (>90 %), and removes interferences effectively. The sample preparation method can also be adapted to ICP-MS measurement of 226Ra, with rapid removal of isobaric interferences.« less
Hayashi, Ami; Okada, Tomonari; Matsumoto, Hiroshi; Nagaoka, Yume; Wada, Toshikazu; Gondo, Asako; Nango, Tomoka; Miyaoka, Yoshitaka; Watanabe, Kanna; Iwata, Azusa; Nakao, Toshiyuki
2013-01-01
We investigate the validity of the assessment of urinary protein excretion by spot urine samples collected by different methods in outpatients with chronic kidney disease (CKD). SUBJECTS AND METHODS We obtained 24-hour urine and two spot urine samples, including the first morning urine and daytime urine in 159 CKD patients. Urinary protein excretion was assessed by the protein/creatinine ratio from spot urine samples (morning: m-UP (g/gCr), daytime: d-UP (g/gCr) ]. We examined the correlations and the differences among m-UP, d-UP and the actual urinary protein excretion obtained by 24-hour urine (a-UP(g/day) . Significant correlations were found between m-UP and a-UP, and between d-UP and a-UP (r = 0.88, 0.85; p < 0.001). Correlations between m-UP and a-UP were greater relative to those between d-UP and a-UP in patients with less than 3.5 g/day of a-UP and in patients with CKD stages 1 to approximately 3. The percent difference between m-UP and a-UP was--16.0 +/- 40.5%, and that between d-UP and a-UP was 27.1 +/- 72.9%. The absolute value of the percent difference between d-UP and a-UP tended to be greater than that between m-UP and a-UP (34.9 +/- 25.9% vs. 49.9 +/- 59.9%, p = 0.06). Urinary protein/creatinie ratio of the first morning urine is better approximate the urinary protein excretion obtained by 24-hour urine compared with that of spot urine in the daytime.
This paper describes the development of a 96-microwell high sample capacity ELISA method for measuring 2,4-D in urine; the analysis of 2,4-D in real-world urine samples by both ELISA and GC/MS methods; and compares the ELISA and GC/MS results in several key areas: accuracy, preci...
Optimization for Peptide Sample Preparation for Urine Peptidomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sigdel, Tara K.; Nicora, Carrie D.; Hsieh, Szu-Chuan
2014-02-25
Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides andmore » the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.« less
Pichini, Simona; De Luca, Roberto; Pellegrini, Manuela; Marchei, Emilia; Rotolo, Maria Concetta; Spoletini, Roberta; D'Aloja, Paola; Pacifici, Roberta; Mortali, Claudia; Scaravelli, Giulia
2012-05-10
For the first time in Europe hair and urine testing have been applied to assess drugs of abuse consumption in couples undergoing assisted reproductive technology and the eventual association of toxic habits with other lifestyle, health status and sociodemographic factors was also investigated. Couples attending five assisted reproduction centers in Rome were invited to join the study. When they presented at the Centre for the visit, they were asked to answer a structured questionnaire concerning sociodemographic characteristics and lifestyle habits, and at the same time to provide hair and urine samples. Hair and urine testing for drugs of abuse, urinary profile of principal endogenous steroids involved in fertility process (testosterone, epitestosterone, androsterone, etiocholanolone and dehydroepiandrosterone) and of alcohol and tobacco smoke biomarkers were performed with validated methodologies. Of the 594 enrolled individuals (297 couples), 352 (164 couples and 24 single individuals from the couple) completed the questionnaire and gave both hair and urine samples, apart from 3 bald men, who only gave urine samples. Urine testing showed an overall 4.8% (17 individuals) positivity to drugs of abuse: 4.2% to cannabinoids, 1.4% to cocaine and 0.85% to both drugs. Results of 4cm segment hair samples testing matched those from urine samples. Thus, taking together, results of urine and hair testing confirmed repeated use of cannabis, cocaine and both drugs in 3.7, 0.85 and 0.57% examined individuals, respectively. Drug consumers were in a statistically higher percentage active smokers and alcohol drinkers, less prone to physical activity and with a trend towards higher weight than non consumers. Finally, repeated drug consumption was associated with significant lower concentration of urinary testosterone in males and of urinary dehydroepiandrosterone in females. The findings of the present study confirm the suitability of urine testing to disclose recent drugs of abuse consumption and of hair analysis to verify repeated consumption. Association between different toxic habits and sedentary lifestyle is also substantiated by the obtained results in our cohort of couples attending assisted reproduction centers. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Ito, Rie; Kawaguchi, Migaku; Honda, Hidehiro; Koganei, Youji; Okanouchi, Noriya; Sakui, Norihiro; Saito, Koichi; Nakazawa, Hiroyuki
2008-09-01
A simple and highly sensitive method that involves hollow-fiber-supported liquid phase microextraction (HF-LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) was developed for the determination of chlorophenols (CPs) such as 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TrCP), 2,3,4,6-tetrachlorophenol (TeCP) and pentachlorophenol (PCP) in human urine samples. Human urine samples were enzymatically de-conjugated with beta-glucuronidase and sulfatase. After de-conjugation, HF-LPME with in situ derivatization was performed. After extraction, 2 microl of extract was carefully withdrawn into a syringe and injected into the GC-MS system. The limits of detection (S/N=3) and quantification (S/N>10) of CPs in the human urine samples are 0.1-0.2 ng ml(-1) and 0.5-1 ng ml(-1), respectively. The calibration curve for CPs is linear with a correlation coefficient of >0.99 in the range of 0.5-500 ng ml(-1) for DCP and TrCP, and of 1-500 ng ml(-1) for TeCP and PCP, respectively. The average recoveries of CPs (n=6) in human urine samples are 81.0-104.0% (R.S.D.: 1.9-6.6%) with correction using added surrogate standards. When the proposed method was applied to human urine samples, CPs were detected at sub-ng ml(-1) level.
Ariyasu, S; Yanai, H; Sato, M; Shinno, Y; Taniguchi, K; Yamadori, I; Miki, Y; Sato, Y; Yoshino, T; Takahashi, K
2015-08-01
Methods for determining the origin of BK virus (BKV)-infected cells (decoy cells) in clinical urine samples have not been established although they could enhance the diagnosis of BKV infection in immunocompromised patients. We performed simultaneous immunostaining with anti-S100P (a urothelial marker) and anti-SV40 antibodies in 66 clinical urine samples exhibiting SV40 positivity and a decoy-cell appearance on Papanicolaou staining. The clinical voided urine samples included seven cases of renal transplantation, 47 cases of cancer therapy and 12 cases of non-neoplastic disease. SurePath(™) liquid-based cytology was used for the urine samples. BKV-infected cells were categorized as SV40(+)/S100P(+) and SV40 (+)/S100p(-). SV40(+)/S100P(-) cells were found in 55 cases (83.4%); nine cases (13.6%) carried both SV40(+)/S100P(-) and SV40(+)/S100P(+) cells. The former were identified as BKV infection in renal tubules and the latter in both the renal tubules and urothelial epithelia. The remaining two cases (3.0%) had only SV40(+)/S100P(+) cells of urothelial origin. Simultaneous immunostaining with anti-S100P and anti-SV40 is a useful method for determining the origin of BKV-infected cells in clinical urine samples from immunocompromised patients such as renal transplantation recipients. © 2014 John Wiley & Sons Ltd.
Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman
2016-01-01
The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer(®) Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible.
Validation of a urine color scale for assessment of urine osmolality in healthy children.
Kavouras, Stavros A; Johnson, Evan C; Bougatsas, Dimitris; Arnaoutis, Giannis; Panagiotakos, Demosthenes B; Perrier, Erica; Klein, Alexis
2016-04-01
Urine color (UC) is a practical tool for hydration assessment. The technique has been validated in adults, but has not been tested in children. The purpose of the study was to test the validity of the urine color scale in young, healthy boys and girls, as a marker of urine concentration, investigate its diagnostic ability of detecting hypohydration and examine the ability of children to self-assess UC. A total of 210 children participated (age: 8-14 years, body mass: 43.4 ± 12.6 kg, height: 1.49 ± 0.13 m, body fat: 25.2 ± 7.8 %). Data collection included: two single urine samples (first morning and before lunch) and 24-h sampling. Hydration status was assessed via urine osmolality (UOsmo) and UC via the eight-point color scale. Mean UC was 3 ± 1 and UOsmo 686 ± 223 mmol kg(-1). UC displayed a positive relationship as a predictor of UOsmo (R (2): 0.45, P < 0.001). Based on the receiver operating curve, UC has good overall classification ability for the three samples (area under the curve 85-92 %), with good sensitivity (92-98 %) and specificity (55-68 %) for detecting hypohydration. The overall accuracy of the self-assessment of UC in the morning or the noon samples ranged from 67 to 78 %. Further threshold analysis indicated that the optimal self-assessed UC threshold for hypohydration was ≥4. The classical eight-point urine color scale is a valid method to assess hydration in children of age 8-14 years, either by researchers or self-assessment.
Roux, Aurélie; Thévenot, Etienne A; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe
There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at -80 °C. Samples were analyzed by high-performance liquid chromatography coupled to high-resolution mass spectrometry and bacterial contamination was monitored by turbidimetry. Multivariate analyses showed that urinary metabolic fingerprints were affected by the presence of preservatives and also by storage at room temperature from 24 to 72 h, whereas no change was observed for urine samples stored at 4 °C over a 72-h period. Investigations were then focused on 280 metabolites previously identified in urine: 19 of them were impacted by the kind of sample collection protocol in both experiments, including 12 metabolites affected by bacterial contamination and 7 exhibiting poor chemical stability. Finally, our results emphasize that the use of preservative prevents bacterial overgrowth, but does not avoid metabolite instability in solution, whereas storage at 4 °C inhibits bacterial overgrowth at least over a 72-h period and slows the chemical degradation process. Consequently, and for further LC/MS analyses, human urine samples should be kept at 4 °C if their collection is performed over 24 h.
Molina, Laurence; Salvetat, Nicolas; Ameur, Randa Ben; Peres, Sabine; Sommerer, Nicolas; Jarraya, Fayçal; Ayadi, Hammadi; Molina, Franck; Granier, Claude
2011-12-10
The characterization of the normal urinary proteome is steadily progressing and represents a major interest in the assessment of clinical urinary biomarkers. To estimate quantitatively the variability of the normal urinary proteome, urines of 20 healthy people were collected. We first evaluated the impact of the sample conservation temperature on urine proteome integrity. Keeping the urine sample at RT or at +4°C until storage at -80°C seems the best way for long-term storage of samples for 2D-GE analysis. The quantitative variability of the normal urinary proteome was estimated on the 20 urines mapped by 2D-GE. The occurrence of the 910 identified spots was analysed throughout the gels and represented in a virtual 2D gel. Sixteen percent of the spots were found to occur in all samples and 23% occurred in at least 90% of urines. About 13% of the protein spots were present only in 10% or less of the samples, thus representing the most variable part of the normal urinary proteome. Twenty proteins corresponding to a fraction of the fully conserved spots were identified by mass spectrometry. In conclusion, a "public" urinary proteome, common to healthy individuals, seems to coexist with a "private" urinary proteome, which is more specific to each individual. Copyright © 2011 Elsevier B.V. All rights reserved.
Cytotoxic drug residues in urine of dogs receiving anticancer chemotherapy.
Knobloch, A; Mohring, S A I; Eberle, N; Nolte, I; Hamscher, G; Simon, D
2010-01-01
The presence of cytotoxic drug residues in urine of dogs may represent an exposure risk for pet owners and other people as well as a potential environmental contaminant. However, studies on cytotoxic drug residues in excretions of clinical patients are lacking in veterinary oncology. Variable concentrations of cytotoxic residues are present in urine samples, depending on sampling time and substance. Client-owned dogs with lymphoma or mast cell tumors treated with standard chemotherapy protocols. Urine samples were collected before, directly after, and on days after administration of chemotherapy. Measurement of vincristine, vinblastine, cyclophosphamide, and doxorubicin residues in canine urine was performed by a quantitative liquid chromatography tandem mass spectrometry (LC/MS/MS) method. Median cyclophosphamide residue concentration was 398.2 microg/L directly after treatment (d0) and was below the level of detection on days 1-3 (d1, d2, d3). Median vincristine residue concentration was 53.8 microg/L directly after treatment and was 20.2, 11.4, and 6.6 microg/L on days 1, 2, and 3. Median vinblastine residues were 144.9 (d0), 70.8 (d1), 35.6 (d2), and 18.7 microg/L (d3) with low concentrations detectable for 7 days after treatment. Median urine doxorubicin concentrations were 354.0 (d0), 165.6 (d1), 156.9 (d2), and 158.2 microg/L (d3). Low concentrations of doxorubicin were measurable up to 21 days after administration. Variable concentrations of chemotherapeutics were measured in urine samples, depending on sampling time point and drug. Findings may inform current chemoprotection guidelines and help minimize exposure risks.
Prednisolone and prednisone neo-formation in bovine urine after sampling.
Arioli, F; Casati, A; Fidani, M; Silvestri, M; Pompa, G
2012-06-01
The rise in the frequency of detecting prednisolone in bovine urine from northern Italy has come into focus of attention in recent years. The possibility that neo-formation of prednisolone or that prednisone may occur in urine after collection of samples was therefore investigated. Cow urine collected for official routine controls in Lombardy containing more than 80 ng/ml cortisol, and prednisolone and prednisone below the decision limit (CCα) of the method (0.4 and 0.5 ng/ml, respectively) was used. The C1-2 dehydrogenation of naturally present cortisol and cortisone was checked by incubating urine, both contaminated and uncontaminated with faeces, at 37°C and by collecting samples at 0, 1, 2, 4, 6 and 24 h. The influence of Helix pomatia juice was also investigated in order to determine whether deconjugation could influence the reliability of the results. All samples were analysed by HPLC-MS3 for the presence of cortisol, cortisone, prednisolone and prednisone in negative electrospray ionisation mode, utilising the consecutive reaction monitoring of product ions derived from the formate molecular adduct ([M+HCOO]-). The observed neo-formation of prednisolone shows that inappropriate temperatures in sample storage and processing can result in an incorrect accusation of non-compliance. The faecal contamination of urine, performed with the aim to mimic a collection conducted without the necessary care, moreover, evoked a high increase in prednisolone concentration in two out of seven animals. Moreover, H. pomatia juice had no significant effect on the prednisolone concentration, indicating that this corticosteroid is present in its free form in cow urine.
Wu, Yiman; Li, Liang
2012-12-18
For mass spectrometry (MS)-based metabolomics, it is important to use the same amount of starting materials from each sample to compare the metabolome changes in two or more comparative samples. Unfortunately, for biological samples, the total amount or concentration of metabolites is difficult to determine. In this work, we report a general approach of determining the total concentration of metabolites based on the use of chemical labeling to attach a UV absorbent to the metabolites to be analyzed, followed by rapid step-gradient liquid chromatography (LC) UV detection of the labeled metabolites. It is shown that quantification of the total labeled analytes in a biological sample facilitates the preparation of an appropriate amount of starting materials for MS analysis as well as the optimization of the sample loading amount to a mass spectrometer for achieving optimal detectability. As an example, dansylation chemistry was used to label the amine- and phenol-containing metabolites in human urine samples. LC-UV quantification of the labeled metabolites could be optimally performed at the detection wavelength of 338 nm. A calibration curve established from the analysis of a mixture of 17 labeled amino acid standards was found to have the same slope as that from the analysis of the labeled urinary metabolites, suggesting that the labeled amino acid standard calibration curve could be used to determine the total concentration of the labeled urinary metabolites. A workflow incorporating this LC-UV metabolite quantification strategy was then developed in which all individual urine samples were first labeled with (12)C-dansylation and the concentration of each sample was determined by LC-UV. The volumes of urine samples taken for producing the pooled urine standard were adjusted to ensure an equal amount of labeled urine metabolites from each sample was used for the pooling. The pooled urine standard was then labeled with (13)C-dansylation. Equal amounts of the (12)C-labeled individual sample and the (13)C-labeled pooled urine standard were mixed for LC-MS analysis. This way of concentration normalization among different samples with varying concentrations of total metabolites was found to be critical for generating reliable metabolome profiles for comparison.
Impedimetric method for measuring ultra-low E. coli concentrations in human urine.
Settu, Kalpana; Chen, Ching-Jung; Liu, Jen-Tsai; Chen, Chien-Lung; Tsai, Jang-Zern
2015-04-15
In this study, we developed an interdigitated gold microelectrode-based impedance sensor to detect Escherichia coli (E. coli) in human urine samples for urinary tract infection (UTI) diagnosis. E. coli growth in human urine samples was successfully monitored during a 12-h culture, and the results showed that the maximum relative changes could be measured at 10Hz. An equivalent electrical circuit model was used for evaluating the variations in impedance characteristics of bacterial growth. The equivalent circuit analysis indicated that the change in impedance values at low frequencies was caused by double layer capacitance due to bacterial attachment and formation of biofilm on electrode surface in urine. A linear relationship between the impedance change and initial E. coli concentration was obtained with the coefficient of determination R(2)>0.90 at various growth times of 1, 3, 5, 7, 9 and 12h in urine. Thus our sensor is capable of detecting a wide range of E. coli concentration, 7×10(0) to 7×10(8) cells/ml, in urine samples with high sensitivity. Copyright © 2014 Elsevier B.V. All rights reserved.
Lawn, Stephen D; Kerkhoff, Andrew D; Burton, Rosie; Schutz, Charlotte; van Wyk, Gavin; Vogt, Monica; Pahlana, Pearl; Nicol, Mark P; Meintjes, Graeme
2015-08-14
Autopsy studies of HIV/AIDS-related hospital deaths in sub-Saharan Africa reveal frequent failure of pre-mortem diagnosis of tuberculosis (TB), which is found in 34-64 % of adult cadavers. We determined the overall prevalence and predictors of TB among consecutive unselected HIV-positive adults requiring acute hospital admission and the comparative diagnostic yield obtained by screening urine and sputum samples obtained on day 1 of admission with Xpert MTB/RIF (Xpert). To determine overall TB prevalence accurately, comprehensive clinical sampling (sputum, urine, blood plus other relevant samples) was done and TB was defined by detection of Mycobacterium tuberculosis in any sample using Xpert and/or mycobacterial liquid culture. To evaluate a rapid screening strategy, we compared the diagnostic yield of Xpert testing sputum samples and urine samples obtained with assistance from a respiratory study nurse in the first 24 h of admission. Unselected HIV-positive acute adult new medical admissions (n = 427) who were not receiving TB treatment were enrolled irrespective of clinical presentation or symptom profile. From 2,391 cultures and Xpert tests done (mean, 5.6 tests/patient) on 1,745 samples (mean, 4.1 samples/patient), TB was diagnosed in 139 patients (median CD4 cell count, 80 cells/μL). TB prevalence was very high (32.6 %; 95 % CI, 28.1-37.2 %; 139/427). However, patient symptoms and risk factors were poorly predictive for TB. Overall, ≥1 non-respiratory sample(s) tested positive in 115/139 (83 %) of all TB cases, including positive blood cultures in 41/139 (29.5 %) of TB cases. In the first 24 h of admission, sputum (spot and/or induced samples) and urine were obtainable from 37.0 % and 99.5 % of patients, respectively (P <0.001). From these, the proportions of total TB cases (n = 139) that were diagnosed by Xpert testing sputum, urine or both sputum and urine combined within the first 24 h were 39/139 (28.1 %), 89/139 (64.0 %) and 108/139 (77.7 %) cases, respectively (P <0.001). The very high prevalence of active TB and its non-specific presentation strongly suggest the need for routine microbiological screening for TB in all HIV-positive medical admissions in high-burden settings. The incremental diagnostic yield from Xpert testing urine was very high and this strategy might be used to rapidly screen new admissions, especially if sputum is difficult to obtain.
Skopp, Gisela; Pötsch, Lucia
2004-01-01
Preanalytical stability of a drug and its major metabolites is an important consideration in pharmacokinetic studies or whenever the analyte pattern is used to estimate drug habits. Firstly, the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH, THCCOOglu) in authentic urine samples was investigated. Random urine samples of cannabis users (n = 38) were stored at -20, 4, and 20 degrees C up to 15 days and up to 5 days at 40 degrees C, and alterations of the analyte pattern during storage were followed by liquid chromatography-tandem mass spectrometry. Secondly, the influence of pH (range 5.0-8.0) on the stability of the analytes was studied using spiked urine to elucidate the results obtained from authentic samples. In authentic urine samples, the initial pH ranged from 5.1 to 8.8. The glucuronide was found to be highly labile at a storage temperature of 4 degrees C and above. Initially, 18 urine samples tested positive for THCCOOH. After 2 days storage at 20 degrees C, THCCOOH was detectable in a further 4 samples, and 7 more samples tested positive for THCCOOH (5-81 ng/mL) after 15 days. Depending on time and temperature, the glucuronide concentration decreased, resulting in an increase of THCCOOH concentration. However, a loss in mean total THCCOOH concentration was found, which was significantly higher in deteriorated samples than in samples without signs of deterioration after 15 days of storage at 20 degrees C. In the drug-free urine sample separately spiked with THCCOOglu or THCCOOH, the investigations on the stability of the target analytes at various pH values revealed that THCCOOH was stable at pH 5.0. At higher pH values, its concentration slightly decreased with time, and about 69% of the initial THCCOOH concentration was still present at pH 8.0 on day 5. THCCOOglu concentrations rapidly decreased with increasing pH value. For example, only 72% of the initial THCCOOglu concentration could be detected at pH 5.0 on day 1. Degradation of the glucuronide resulted in formation of THCCOOH, which was observed even at pH 5.0. In light of the present findings, advanced forensic interpretations based on the presence of THCCOOH or the pattern of THCCOOH and THCCOOglu in stored urine samples seems questionable.
Leese, Elizabeth; Morton, Jackie; Gardiner, Philip H E; Carolan, Vikki A
2017-04-01
The analytical method outlined in this feasibility study has been used to show that trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)) can be detected and measured in exhaled breath condensate (EBC) samples. EBC samples and urine samples were collected from a cohort of 58 workers occupationally exposed to hexavalent chromium compounds and 22 unexposed volunteers (control group). Levels of Cr(III) and Cr(VI) were determined in EBC samples and total chromium levels were determined in urine samples. Pre and post working week samples for both EBC and urine were collected in tandem. Total chromium in urine samples was analysed by inductively coupled plasma mass spectrometry (ICP-MS). Analysis of Cr(III) and Cr(VI) in EBC samples used a hyphenated micro liquid chromatography (μLC) system coupled to an ICP-MS. Separation was achieved using an anion exchange micro-sized column. The results showed that the occupationally exposed workers had significantly higher levels of Cr(III) and Cr(VI) in their EBC samples than the control group, as well as higher levels of total chromium in their urine samples. However, for the exposed workers no significant difference was found between pre and post working week EBC samples for either Cr(III) or Cr(VI). This study has established that Cr(III) and Cr(VI) can simultaneously be detected and measured in 'real' EBC samples and will help in understanding inhalation exposure. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.
Electrical conductivity and total dissolved solids in urine.
Fazil Marickar, Y M
2010-08-01
The objective of this paper is to study the relevance of electrical conductivity (EC) and total dissolved solids (TDS) in early morning and random samples of urine of urinary stone patients; 2,000 urine samples were studied. The two parameters were correlated with the extent of various urinary concrements. The early morning urine (EMU) and random samples of the patients who attended the urinary stone clinic were analysed routinely. The pH, specific gravity, EC, TDS, redox potential, albumin, sugar and microscopic study of the urinary sediments including red blood cells (RBC), pus cells (PC), crystals, namely calcium oxalate monohydrate (COM), calcium oxalate dihydrate (COD), uric acid (UA), and phosphates and epithelial cells were assessed. The extent of RBC, PC, COM, COD, UA and phosphates was correlated with EC and TDS. The values of EC ranged from 1.1 to 33.9 mS, the mean value being 21.5 mS. TDS ranged from 3,028 to 18,480 ppm, the mean value being 7,012 ppm. The TDS levels corresponded with EC of urine. Both values were significantly higher (P < 0.05) in the EMU samples than the random samples. There was a statistically significant correlation between the level of abnormality in the urinary deposits (r = +0.27, P < 0.05). In samples, where the TDS were more than 12,000 ppm, there were more crystals than those samples containing TDS less than 12,000 ppm. However, there were certain urine samples, where the TDS were over 12,000, which did not contain any urinary crystals. It is concluded that the value of TDS has relevance in the process of stone formation.
Röhrich, J; Schimmel, I; Zörntlein, S; Becker, J; Drobnik, S; Kaufmann, T; Kuntz, V; Urban, R
2010-05-01
Cannabinoid concentrations in blood and urine after passive exposure to cannabis smoke under real-life conditions were investigated in this study. Eight healthy volunteers were exposed to cannabis smoke for 3 h in a well-attended coffee shop in Maastricht, Netherlands. An initial blood and urine sample was taken from each volunteer before exposure. Blood samples were taken 1.5, 3.5, 6, and 14 h after start of initial exposure, and urine samples were taken after 3.5, 6, 14, 36, 60, and 84 h. The samples were subjected to immunoassay screening for cannabinoids and analyzed using gas chromatography-mass spectrometry (GC-MS) for Delta(9)-tetrahydrocannabinol (THC), 11-nor-hydroxy-Delta(9)-tetrahydrocannabinol (THC-OH), and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH). It could be demonstrated that all volunteers absorbed THC. However, the detected concentrations were rather small. None of the urine samples produced immunoassay results above the cutoff concentration of 25 ng/mL. THC-COOH concentrations up to 5.0 and 7.8 ng/mL before and after hydrolysis, respectively, were found in the quantitative GC-MS analysis of urine. THC could be detected in trace amounts close to the detection limit of the used method in the first two blood samples after initial exposure (1.5 and 3.5 h). In the 6 h blood samples, THC was not detectable anymore. THC-COOH could be detected after 1.5 h and was still found in 3 out of 8 blood samples after 14 h in concentrations between 0.5 and 1.0 ng/mL.
Tan, Susanna K; Sahoo, Malaya K; Milligan, Stephen B; Taylor, Nathaniel; Pinsky, Benjamin A
2017-10-01
Detection of Zika virus (ZIKV) RNA in urine is of increasing interest for the diagnosis of ZIKV infection. Pre-analytical variables can significantly impact the stability of RNA in urine. To determine optimal specimen processing protocols that would maximize detection of ZIKV RNA in urine by real-time, reverse transcriptase PCR, we investigated the effect of temperature, initial ZIKV concentration, use of nucleic acid stabilizers, and time on ZIKV RNA levels. Urine samples from healthy donors were spiked with ZIKV using the Exact Diagnostics ® ZIKV Verification Panel, a commercially available panel composed of heat-inactivated ZIKV, at concentrations of 5.0 log 10 copies/mL (ZIKV-high) and 4.0 log 10 copies/mL (ZIKV-low). Samples were stored at room temperature, 4°C, or -80°C and frozen aliquots were exposed to no stabilizer (urine), Buffer ATL (Qiagen, Germantown, MD), or DNA/RNA Shield (Zymo Research, Irvine, CA). ZIKV RNA levels in urine declined steadily at room temperature, though was not significant by 48h (ZIKV-high, p=0.09; ZIKV-low, p=0.20). ZIKV RNA titers were consistently higher when stored at 4°C, suggesting that storage at 4°C can slow the progression of RNA degradation. Freezing urine samples at -80°C resulted in a significant loss of detectable ZIKV RNA in the ZIKV-low group. ZIKV RNA was detected in 5/6 replicates at 3days, 1/6 replicates at 10days, and 1/3 replicates at 30days, with findings reproducible on repeat testing. Presence of either nucleic acid stabilizer in urine corrected this effect, and resulted in recovery of ZIKV RNA in all replicates. Use of a nucleic acid stabilizer in the ZIKV-high group did not add incremental benefit for the detection or quantitation of ZIKV RNA. ZIKV RNA is prone to degradation in urine with loss of detectable virus even when specimens are frozen at -80°C for 10days. Detection of ZIKV-positive urine samples, particularly those containing low ZIKV titers may be aided with the addition of a nucleic acid stabilizer during urine specimen processing. Copyright © 2017. Published by Elsevier B.V.
McGuire, Barry B; Bhanji, Yasin; Sharma, Vidit; Frainey, Brendan T; McClean, Megan; Dong, Caroline; Rimar, Kalen; Perry, Kent T; Nadler, Robert B
2015-06-01
We aimed to understand the characteristics of patients who are less likely to submit adequate urine collections at metabolic stone evaluation. Inadequate urine collection was defined using two definitions: (1) Reference ranges for 24-hour creatinine/kilogram (Cr/24) and (2) discrepancy in total 24-hour urine Cr between 24-hour urine collections. There were 1502 patients with ≥1 kidney stone between 1998 and 2014 who performed a 24- or 48-hour urine collection at Northwestern Memorial Hospital and who were identified retrospectively. Multivariate analysis was performed to analyze predictor variables for adequate urine collection. A total of 2852 urine collections were analyzed. Mean age for males was 54.4 years (range 17-86), and for females was 50.2 years (range 8-90). One patient in the study was younger than 17 years old. (1) Analysis based on the Cr 24/kg definition: There were 50.7% of patients who supplied an inadequate sample. Females were nearly 50% less likely to supply an adequate sample compared with men, P<0.001. Diabetes (odds ratio [OR] 1.42 [1.04-1.94], P=0.026) and vitamin D supplementation (OR 0.64 [0.43-0.95], P=0.028) predicted receiving an adequate/inadequate sample, respectively. (2) Analysis based on differences between total urinary Cr: The model was stratified based on percentage differences between samples up to 50%. At 10%, 20%, 30%, 40%, and 50% differences, inadequate collections were achieved in 82.8%, 66.9%, 51.7%, 38.5%, and 26.4% of patients, respectively. Statistical significance was observed based on differences of ≥40%, and this was defined as the threshold for an inadequate sample. Female sex (OR 0.73 [0.54-0.98], P=0.037) predicted supplying inadequate samples. Adequate collections were more likely to be received on a Sunday (OR 1.6 [1.03-2.58], P=0.038) and by sedentary workers (OR 2.3 [1.12-4.72], P=0.023). Urine collections from patients during metabolic evaluation for nephrolithiasis may be considered inadequate based on two commonly used clinical definitions. This may have therapeutic or economic ramifications and the propensity for females to supply inadequate samples should be investigated further.
Majumdar, Deepanjan; Patel, Manoj; Drabar, Reena; Vyas, Manish
2006-11-01
The study was designed to understand the emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) from a single cattle urination event on a tropical grassland and underline the significance of the emissions in the context of huge animal population grazing on large pasture areas in some countries. Emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) were monitored for three weeks from a tropical grassland (dominated by Cynodon dactylon Pers.) microcosm contaminated with cow and buffalo urine. The grassland microcosms were treated with urine (50 and 100 ml of each) only once and irrigated with water once every week. Ammonia was sampled by an automatic sampling system comprising of a vacuum pump, three-way stopcocks and rubber tubing and an impinger containing suitable absorbing solution (H(2)SO(4)), connected to the tubing suitably. The sampled gas, after sucked by the vacuum pump and absorbed in H(2)SO(4), was allowed to enter the closed microcosm again maintaining internal pressure of the microcosm. Carbon dioxide was sampled by absorption in an alkali (NaOH) trap inside the microcosm. Both NH(3) and CO(2) emissions were highly variable temporally and there was no continuous increasing or decreasing emission trend with time. Respectively, 45 and 46% of total NH(3)-N were emitted within first 48 h from 50 and 100 ml cow urine application while the corresponding values for buffalo urine were 34 and 32%. Total NH(3)-N emissions, integrated for sampling days (i.e. 1, 2, 3, 4, 6, 15, 18 and 21st) were 11 and 6% in cow and 8 and 5% in buffalo urine, of the total-N added through 50 and 100 ml urine samples. Carbon dioxide emissions were standardized at 25 degrees C by using a suitable formula which were lower than actual emissions at actual soil temperature (> 25 degrees C). Carbon dioxide emission rates were classified on the basis of soil repiratory classification and classes ranged from moderately low soil activity up to unusually high soil activity, the latter observed only on very few sampling days. Grasses in the microcosm had shown appreciable growth after urine application. Although variable and somewhat unpredictable, emissions were appreciable and that too only from a patch of single urination, indicating to the huge magnitude of total emissions under the scenario of thousands of cattle grazing on hundreds of acres of grasslands in a tropical country.
Katayev, Alexander; Zebelman, Arthur M; Sharp, Thomas M; Samantha Flynn; Bernstein, Richard K
2017-04-01
Isolated non-albumin proteinuria (NAP) is a condition when urine total protein concentrations are elevated without elevation of urine albumin. The prevalence of NAP in the US population tested for both, urine total protein and albumin was assessed in this study. The database of a US nationwide laboratory network was queried for test results when random urine albumin was ordered together with urine total protein and also when timed 24-hour urine albumin was ordered together with urine total protein. The total prevalence of NAP in the US population tested for both, urine total protein and albumin was calculated for patient groups having normal and low-normal urine albumin (random and timed) with elevated and severely increased urine total protein (random and timed). Also, the prevalence of NAP was calculated for patients with normal urine albumin to assess the probability of missing proteinuria if only urine albumin is measured. The prevalence of NAP in the random samples group was 10.1% (15.2% for females and 4.7% for males). Among patients with normal random albumin, there were 20.0% (27.3% of females and 10.7% of males) patients with NAP. The prevalence of NAP in the timed samples group was 24.6% (29.8% for females and 18.5% for males). Among patients with normal timed urine albumin, there were 36.2% (40.0% of females and 30.8% of males) patients with NAP. There was a strong positive association with female gender and NAP in most patients groups. Testing for only urine (micro)albumin can miss up to 40% of females and 30.8% of males with gross proteinuria. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Characterization of ultrafiltration of undiluted and diluted stored urine.
Ouma, J; Septien, S; Velkushanova, K; Pocock, J; Buckley, C
2016-11-01
Urine ultrafiltration (UF) was studied in terms of flux, permeability, resistance and fouling. Two types of samples were used: stored urine representing the feedstock obtained from urine diversion dry toilets; and diluted stored urine representing the feedstock obtained from urinals. Three different filtration experiment sets were adopted in this study. For the first case, pressure was set in an ascending order, i.e. from 10 to 60 kPa during filtration of stored urine. For the second case, pressure was set in a descending order, i.e. from 60 to 10 kPa for the same feed stream. The third case involved filtration of diluted urine with pressure in ascending order, i.e. from 10 to 60 kPa. The results indicated that diluted urine had higher flux than undiluted urine with maximum values of 43 and 26 L·m -2 ·h -1 respectively. Cake formation was the dominating fouling mechanism during urine filtration with a contribution of about 90% to the total hydraulic resistance. The contribution of chemically irreversible fouling was low (-2%), unless operating from high to low pressures. Indeed, irreversible fouling appeared to be greater during the experiments starting at higher pressure. Although undiluted urine had a higher fouling potential compared to diluted urine, the specific cake resistance was higher for diluted urine, probably due to a denser cake caused by lower particle sizes in that sample. The permeate obtained after urine filtration had much lower suspended solids content compared to the feedstock, with rejections up to 99%. The concentration of the ionic species remained unchanged, and 75% of the organic compounds and dissolved solids remained in the permeate. Urine UF could then be used as pre-treatment to remove suspended solids.
... Why do I need a nitrites in urine test? Your health care provider may have ordered a urinalysis as part ... Fever What happens during a nitrites in urine test? Your health care provider will need to collect a sample of ...
... Why do I need a urobilinogen in urine test? Your health care provider may have ordered this test as part ... skin What happens during a urobilinogen in urine test? Your health care provider will need to collect a sample of ...
Microbiological test results using three urine pretreatment regimes with 316L stainless steel
NASA Technical Reports Server (NTRS)
Huff, Timothy L.
1993-01-01
Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.
Carbon-monoxide poisoning in young drug addicts due to indoor use of a gasoline-powered generator.
Marc, B; Bouchez-Buvry, A; Wepierre, J L; Boniol, L; Vaquero, P; Garnier, M
2001-06-01
We report six fatal cases of unintentional carbon-monoxide poisoning which occurred in a house occupied by young people. The source of carbon monoxide was a gasoline-powered generator. For all victims, an external body examination was carried out and blood and urine samples collected. Blood carboxyhaemoglobin (COHb) was performed using an automated visible spectrophotometric analysis. Blood-alcohol level quantification was performed using gas chromatography and drug screening in urine was performed by a one-step manual qualitative immunochromatography (Syva Rapid test, Behring Diagnostics Inc.) for benzoylecgonine (the main metabolite of cocaine in urine), morphine, 11-nor-Delta(9)-THC-9-COOH (cannabinoids) and d-methamphetamine. In all victims the COHb value was as high or higher than 65%. No alcohol was found in blood samples, but urine samples were positive for methamphetamine, cocaine and cannabis in five cases and for opiates in one case. In four victims, the urine sample was positive for at least three drugs. The availability and accuracy of rapid toxicological screening is an important tool for the medical examiner at the immediate scene of a clinical forensic examination.
Bos, R P; Kromhout, H; Ikink, H; de Haan, W; Koppejan, J; Theuws, J L
1989-05-01
In an aircraft type retreading plant environmental samples taken at several departments showed mutagenic properties. Thursday urine samples of non-smoking and smoking workers showed higher urinary mutagenicity than urine samples collected on Sundays, thus suggesting occupational exposure to mutagenic substances. A relation between urinary mutagenicity on Thursdays and skin contamination measured on Wednesdays was observed. The data suggest that intake through the skin plays an important role in the occupational exposure to mutagenic compounds of rubber workers.
Cheuvront, Samuel N; Muñoz, Colleen X; Kenefick, Robert W
2016-09-01
Urine concentration can be used to assess fluid intake adequacy or to diagnose dehydration. However, too often urine concentration is used inappropriately to draw dubious conclusions that could have harmful health and economic consequences. Inappropriate uses of urine concentration relate primarily to convenience sampling (timing) and problems related to convenience sampling (misapplication of thresholds), but a conceptual problem also exists with using urine concentration in isolation. The purpose of this Perspective article is to briefly explain the problematic nature of current practices and to offer a possible solution to improve practice with minimal added complication. When urine is used exclusively to assess fluid intake adequacy and hydration status in adults, we propose that only when urine concentration is high (>850 mmol/kg) and urine excretion rate is low (<850 mL/24 h) should suspicion of inadequate drinking or impending dehydration be considered. Prospective tests of the 850 × 850 thresholds will provide supporting evidence and/or help refine the best thresholds for men and women, young and old. © 2016 American Society for Nutrition.
Objective non-intrusive markers of sperm production and sexual activity
Sivananthan, Thilee; Bathur, Franz; Jimenez, Mark; Conway, Ann; Idan, Amanda; Handelsman, David
2012-01-01
Objective studies of men's reproductive function are hindered by their reliance on: (i) self-reporting to quantify sexual activity and (ii) masturbation to quantify sperm output rendering both types of estimate vulnerable to unverifiable subjective factors. We therefore examined whether detection of spermatozoa and measurement of prostate-specific antigen (PSA) in urine could provide objective semiquantitative estimates of sperm output and recent ejaculation, respectively, using widely available laboratory techniques. Of 11 healthy volunteers who provided urine samples before and at intervals for 5 days after ejaculation, sperm was present in 2/11 men before, and in all 11/11 samples immediately after ejaculation, but by the second and subsequent void, spermatozoa were present in ∼10%. PSA was detectable at high levels in all urine samples, peaking at the first post-ejaculatory sample but returning to baseline levels by the second post-ejaculatory void. We conclude that urinary spermatozoa and PSA are objective biomarkers for sperm production and sexual activity, but only for a short-time window until the first post-ejaculatory urine void. Hence, for a single urine specimen, the presence of spermatozoa and PSA are valid biomarkers, reflecting sperm production and recent ejaculation only until the next micturition, so their measurement should be restricted to the first morning urine void. PMID:22522506
Ahmed, Hytham M; Ebeid, Wael B
2015-05-15
Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200ng/ml respectively and recovery was >98% (n=5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period. Copyright © 2015 Elsevier B.V. All rights reserved.
Veland, Nicolas; Espinosa, Diego; Valencia, Braulio Mark; Ramos, Ana Pilar; Calderon, Flor; Arevalo, Jorge; Low, Donald E.; Llanos-Cuentas, Alejandro; Boggild, Andrea K.
2011-01-01
We hypothesized that Leishmania kDNA may be present in urine of patients with cutaneous leishmaniasis (CL). Urine samples and standard diagnostic specimens were collected from patients with skin lesions. kDNA polymerase chain reaction (PCR) was performed on samples from patients and 10 healthy volunteers from non-endemic areas. Eighty-six of 108 patients were diagnosed with CL and 18 (21%) had detectable Leishmania Viannia kDNA in the urine. Sensitivity and specificity were 20.9% (95% confidence interval [CI] 12.3–29.5%) and 100%. Six of 8 patients with mucocutaneous involvement had detectable kDNA in urine versus 12 of 78 patients with isolated cutaneous disease (P < 0.001). L. (V.) braziliensis (N = 3), L. (V.) guyanensis (N = 6), and L. (V.) peruviana (N = 3) were identified from urine. No healthy volunteer or patient with an alternate diagnosis had detectable kDNA in urine. Sensitivity of urine PCR is sub-optimal for diagnosis. On the basis of these preliminary data in a small number of patients, detectable kDNA in urine may identify less localized forms of infection and inform treatment decisions. PMID:21460009
Stamping SERS for creatinine sensing
NASA Astrophysics Data System (ADS)
Li, Ming; Du, Yong; Zhao, Fusheng; Zeng, Jianbo; Santos, Greggy M.; Mohan, Chandra; Shih, Wei-Chuan
2015-03-01
Urine can be obtained easily, readily and non-invasively. The analysis of urine can provide metabolic information of the body and the condition of renal function. Creatinine is one of the major components of human urine associated with muscle metabolism. Since the content of creatinine excreted into urine is relatively constant, it is used as an internal standard to normalize water variations. Moreover, the detection of creatinine concentration in urine is important for the renal clearance test, which can monitor the filtration function of kidney and health status. In more details, kidney failure can be imminent when the creatinine concentration in urine is high. A simple device and protocol for creatinine sensing in urine samples can be valuable for point-of-care applications. We reported quantitative analysis of creatinine in urine samples by using stamping surface enhanced Raman scattering (S-SERS) technique with nanoporous gold disk (NPGD) based SERS substrate. S-SERS technique enables label-free and multiplexed molecular sensing under dry condition, while NPGD provides a robust, controllable, and high-sensitivity SERS substrate. The performance of S-SERS with NGPDs is evaluated by the detection and quantification of pure creatinine and creatinine in artificial urine within physiologically relevant concentration ranges.
Pure human urine is a good fertiliser for cucumbers.
Heinonen-Tanski, Helvi; Sjöblom, Annalena; Fabritius, Helena; Karinen, Päivi
2007-01-01
Human urine obtained from separating toilets was tested as a fertiliser for cultivation of outdoor cucumber (Cucumis sativus L.) in a Nordic climate. The urine used contained high amounts of nitrogen with some phosphorus and potassium, but numbers of enteric microorganisms were low even though urine had not been preserved before sampling. The cucumber yield after urine fertilisation was similar or slightly better than the yield obtained from control rows fertilised with commercial mineral fertiliser. None of the cucumbers contained any enteric microorganisms (coliforms, enterococci, coliphages and clostridia). In the taste assessment, 11 out of 20 persons could recognise which cucumber of three cucumbers was different but they did not prefer one over the other cucumber samples, since all of them were assessed as equally good.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hawkins, C.; Dietz, M.; Kaminski, M.
2016-03-01
A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial,more » extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.« less
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS
The Pesticide Metabolites in Urine data set contains the analytical results for measurements of up to 8 pesticide metabolites in 86 samples over 86 households. Each sample was collected form the primary respondent within each household. The sample consists of the first morning ...
Nakashima, Kazufumi; Shigehara, Kazuyoshi; Kitamura, Tadaichi; Yaegashi, Hiroshi; Shimamura, Masayoshi; Kawaguchi, Shohei; Izumi, Kouji; Kadono, Yoshifumi; Mizokami, Atsushi
2018-05-11
The present study aimed to investigate human papillomavirus (HPV) prevalence and identify risk factors for HPV detection in urine samples among heterosexual men attending urological clinics. Spot urine samples including initial stream were collected from 845 participants, and the cell pellets were preserved into liquid-based cytological solution. After DNA extraction from each sample, HPV-DNA amplification and genotyping were performed using Luminex multiplex polymerase chain reaction. Participants completed a questionnaire on their age, education, smoking status, sexuality, age of sexual debut, marital status, and present history of sexually transmitted infections. Data from 803 patients were included in the analysis. Overall HPV and high-risk (HR)HPV prevalence in urine samples were 6.2% and 3.1%, respectively. HPV and HR-HPV prevalences were the highest in men with urethritis, and were significantly higher than those without urethritis. HPV detection was the most common in men aged 40-49 years, although significant detection differences were not age-related. Urethritis was an independent risk factor for HPV detection from urine samples, with an odds ratio (OR) of 4.548 (95%CI; 1.802-11.476) (p = 0.001). On the other hand, a sub-analysis excluding men with urethritis demonstrated that prostate cancer was a significant risk factor for HPV detection, with OR of 2.844 (95%CI; 1.046-7.732) (p = 0.0410), whereas was not a significant risk for HR-HPV detection in urine samples. Prostate cancer may represent a risk factor for HPV detection in the urine of men without urethritis. The authors did not register to Clinical Trial because this is observational and cross-sectional study. Copyright © 2018 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Detection of depleted uranium in urine of veterans from the 1991 Gulf War.
Gwiazda, R H; Squibb, K; McDiarmid, M; Smith, D
2004-01-01
American soldiers involved in "friendly fire" accidents during the 1991 Gulf War were injured with depleted-uranium-containing fragments or possibly exposed to depleted uranium via other routes such as inhalation, ingestion, and/or wound contamination. To evaluate the presence of depleted uranium in these soldiers eight years later, the uranium concentration and depleted uranium content of urine samples were determined by inductively coupled plasma mass spectrometry in (a) depleted uranium exposed soldiers with embedded shrapnel, (b) depleted uranium exposed soldiers with no shrapnel, and (c) a reference group of deployed soldiers not involved in the friendly fire incidents. Uranium isotopic ratios measured in many urine samples injected directly into the inductively coupled plasma mass spectrometer and analyzed at a mass resolution m/delta m of 300 appeared enriched in 235U with respect to natural abundance (0.72%) due to the presence of an interference of a polyatomic molecule of mass 234.81 amu that was resolved at a mass resolution m/delta m of 4,000. The 235U abundance measured on uranium separated from these urines by anion exchange chromatography was clearly natural or depleted. Urine uranium concentrations of soldiers with shrapnel were higher than those of the two other groups, and 16 out of 17 soldiers with shrapnel had detectable depleted uranium in their urine. In depleted uranium exposed soldiers with no shrapnel, depleted uranium was detected in urine samples of 10 out of 28 soldiers. The median uranium concentration of urines with depleted uranium from soldiers without shrapnel was significantly higher than in urines with no depleted uranium, though substantial overlap in urine uranium concentrations existed between the two groups. Accordingly, assessment of depleted uranium exposure using urine must rely on uranium isotopic analyses, since urine uranium concentration is not an unequivocal indicator of depleted uranium presence in soldiers with no embedded shrapnel.
Struys, E A; Jansen, E E W; Gibson, K M; Jakobs, C
2005-01-01
Succinic semialdehyde (SSA) accumulates in the inborn error of meta- bolism succinic semialdehyde dehydrogenase deficiency owing to impaired enzymatic conversion to succinic acid. We developed a stable-isotope dilution liquid chromato- graphy-tandem mass spectrometry method for the determination of SSA in urine and cerebrospinal fluid samples. Stable-isotope-labelled [13C4]SSA, serving as internal standard, was prepared by reaction of ninhydrin with L-[13C5]glutamic acid. SSA in body fluids was converted to its dinitrophenylhydrazine (DNPH) derivative, without sample purification prior to the derivatization procedure. The DNPH derivative of SSA was injected onto a C18 analytical column and chromatography was performed by isocratic elution. Detection was accomplished by tandem mass spectrometry operating in the negative multiple-reaction monitoring mode. The limit of detection was 10 nmol/L and the calibration curves over the range 0-500 pmol of SSA showed good linearity (r2 > 0.99). The intra-day coefficient of variation (n = 10) for urine was 2.7% and inter-day coefficient of variation (n = 5) for urine was 8.5%. The average recoveries performed on two levels by enriching urine and cerebrospinal fluid samples ranged between 85 and 115%, with coefficients of variation < 8%. The method enabled the first determination of normal values for SSA in urine and pathological values of SSA in urine and cerebrospinal fluid samples derived from patients with succinic semialdehyde dehydrogenase deficiency.
Urine Sample Preparation in 96-Well Filter Plates for Quantitative Clinical Proteomics
2015-01-01
Urine is an important, noninvasively collected body fluid source for the diagnosis and prognosis of human diseases. Liquid chromatography mass spectrometry (LC-MS) based shotgun proteomics has evolved as a sensitive and informative technique to discover candidate disease biomarkers from urine specimens. Filter-aided sample preparation (FASP) generates peptide samples from protein mixtures of cell lysate or body fluid origin. Here, we describe a FASP method adapted to 96-well filter plates, named 96FASP. Soluble urine concentrates containing ∼10 μg of total protein were processed by 96FASP and LC-MS resulting in 700–900 protein identifications at a 1% false discovery rate (FDR). The experimental repeatability, as assessed by label-free quantification and Pearson correlation analysis for shared proteins among replicates, was high (R ≥ 0.97). Application to urinary pellet lysates which is of particular interest in the context of urinary tract infection analysis was also demonstrated. On average, 1700 proteins (±398) were identified in five experiments. In a pilot study using 96FASP for analysis of eight soluble urine samples, we demonstrated that protein profiles of technical replicates invariably clustered; the protein profiles for distinct urine donors were very different from each other. Robust, highly parallel methods to generate peptide mixtures from urine and other body fluids are critical to increase cost-effectiveness in clinical proteomics projects. This 96FASP method has potential to become a gold standard for high-throughput quantitative clinical proteomics. PMID:24797144
Seasonal variation in natural abundance of 2H and 18O in urine samples from rural Nigeria
Dugas, Lara R.; Brieger, William; Tayo, Bamidele O.; Alabi, Tunrayo; Schoeller, Dale A.; Luke, Amy
2015-01-01
The doubly labeled water (DLW) method is used to measure free-living energy expenditure in humans. Inherent to this technique is the assumption that natural abundances of stable isotopes 2H and 18O in body water remain constant over the course of the measurement period and after elimination of the loading dose of DLW will return to the same predose level. To determine variability in the natural abundances of 2H and 18O in humans living in a region with seasonal shifts in rain patterns and sources of drinking water, over the course of 12 mo we collected weekly urine samples from four individuals living in southwest Nigeria as well as samples of their drinking water. From ongoing regional studies of hypertension, obesity, and energy expenditure, we estimated average water turnover rate, urine volumes, and sodium and potassium excretion. Results suggest that 2H and 18O in urine, mean concentrations of urinary sodium and potassium, urine volume, and total body turnover differed significantly from dry to rainy season. Additionally, seasonal weather variables (mean monthly maximum temperatures, total monthly rainfall, and minimum relative humidity) were all significantly associated with natural abundances in urine. No seasonal difference was observed in drinking water samples. Findings suggest that natural abundances in urine may not remain constant as assumed, and studies incorporating DLW measurements across the transition of seasons should interpret results with caution unless appropriate doses of the tracers are used. PMID:25977450
Chemical Method of Urine Volume Measurement
NASA Technical Reports Server (NTRS)
Petrack, P.
1967-01-01
A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.
Dehnes, Yvette; Shalina, Alexandra; Myrvold, Linda
2013-01-01
The misuse of microdoses of performance enhancing drugs like erythropoietin (EPO) constitutes a major challenge in doping analysis. When injected intravenously, the half-life of recombinant human EPO (rhEPO) like epoetin alfa, beta, and zeta is only a few hours and hence, the window for direct detection of rhEPO in urine is small. In order to investigate the detection window for rhEPO directly in blood and urine with a combined affinity chromatography and lateral flow immunoassay (EPO WGA MAIIA), we recruited nine healthy people who each received six intravenously injected microdoses (7.5 IU/kg) of NeoRecormon (epoetin beta) over a period of three weeks. Blood and urine samples were collected in the days following the injections and analyzed with EPO WGA MAIIA as well as the current validated methods for rhEPO; isoelectric focusing (IEF) and sarcosyl polyacrylamide gel electrophoresis (SAR-PAGE). For samples collected 18 h after a microdose, the sensitivity of the EPO WGA MAIIA assay was 100% in plasma and 87.5% in urine samples at the respective 98% specificity threshold levels. In comparison, the sensitivity in plasma and urine was 75% and 100%, respectively, with IEF, and 87.5% in plasma and 100% in urine when analyzed with SAR-PAGE. We conclude that EPO WGA MAIIA is a sensitive assay for the detection of rhEPO, with the potential of being a fast, supplemental screening assay for use in doping analysis.
Flow-injection chemiluminescence determination of melamine in urine and plasma.
Tang, Xiaoshuang; Shi, Xiyan; Tang, Yuhai; Yue, Zhongjin; He, Qiqi
2012-01-01
A novel flow-injection chemiluminescence method for the determination of melamine in urine and plasma was developed. It was found that melamine can remarkably enhance chemiluminescence emission from the luminol-K(3) Fe(CN)(6) system in an alkaline medium. Under the optimum conditions, chemiluminescence intensity had a good linear relationship with the concentration of melamine in the range 9.0 × 10(-9) -7.0 × 10(-6) g/mL, with a correlation coefficient of 0.9992. The detection limit (3σ) was 3.5 ng/mL. The method has been applied to determine the concentration of melamine in samples using liquid-liquid extraction. Average recoveries of melamine were 102.6% in urine samples and 95.1% in plasma samples. The method provided a reproducible and stable approach for the sensitive detection of melamine in urine and plasma samples. Copyright © 2011 John Wiley & Sons, Ltd.
Detection of West Nile virus lineage 2 in the urine of acute human infections.
Papa, Anna; Testa, Theodolinda; Papadopoulou, Elpida
2014-12-01
West Nile virus (WNV) lineage 2 emerged in Greece in 2010 and since then outbreaks in humans have been reported for four consecutive years. Laboratory diagnosis is based mainly on serology. A real-time RT-PCR was applied on urine samples obtained from 35 patients with acute WNV infection. WNV RNA was detected in 40% of the samples with cycle threshold (CT) values ranging from 26.95 to 39.89 (mean 33.11). WNV was isolated from two of four urine samples with low CT (<30). Viral load was not associated with patients' age, sex, day of illness, presence of WNV antibodies, and neurological symptoms. However, it seems that sample shipment and storage conditions are very important for virus detection and isolation. The usefulness of the WNV RNA detection in urine as a diagnostic tool of acute WNV infections is discussed. © 2014 Wiley Periodicals, Inc.
Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D
2006-03-01
Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.
Fidani, Marco; Casagni, Eleonora; Montana, Marco; Pasello, Emanuela; Pecoraro, Chiara; Gambaro, Veniero
2006-01-01
Bacteria frequently found in equine urine samples may cause degradation of 17beta-OH steroids. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to evaluate the microbiological contamination of equine urine as a marker of poor storage conditions. Norethandrolone was used as the internal standard, and the linearity, sensitivity, precision and accuracy of the method were evaluated. 17beta-OH oxidation was demonstrated for testosterone, nandrolone, trenbolone and boldenone, but did not occur in alpha-epimers such as alpha-boldenone and epitestosterone, demonstrating the stereoselectivity of the reaction. A rapid test was performed by spiking one of the four 17beta-OH steroids in samples of diluted equine urine. The steroids were transformed into their respective ketones in the presence of bacterial activity. The test allows direct injection of diluted samples into the LC/MS system, without the need for prior extraction. Results show that the best method of storage is freezing at -18 degrees C. Urine specimens should be analyzed as soon as possible after thawing. This allows bacterial degradation of equine urine to be arrested temporarily, so that the urine can be used for qualitative or quantitative analysis of 17beta-OH steroids.
Gandasegui, Javier; Bajo Santos, Cristina; López-Abán, Julio; Saugar, José María; Rodríguez, Esperanza; Vicente, Belén; Muro, Antonio
2016-01-01
Background Strongyloides stercoralis, the chief causative agent of human strongyloidiasis, is a nematode globally distributed but mainly endemic in tropical and subtropical regions. Chronic infection is often clinically asymptomatic but it can result in severe hyperinfection syndrome or disseminated strongyloidiasis in immunocompromised patients. There is a great diversity of techniques used in diagnosing the disease, but definitive diagnosis is accomplished by parasitological examination of stool samples for morphological identification of parasite. Until now, no molecular method has been tested in urine samples as an alternative to stool samples for diagnosing strongyloidiasis. This study aimed to evaluate the use of a new molecular LAMP assay in a well-established Wistar rat experimental infection model using both stool and, for the first time, urine samples. The LAMP assay was also clinically evaluated in patients´ stool samples. Methodology/Principal Findings Stool and urine samples were obtained daily during a 28-day period from rats infected subcutaneously with different infective third-stage larvae doses of S. venezuelensis. The dynamics of parasite infection was determined by daily counting the number of eggs per gram of feces from day 1 to 28 post-infection. A set of primers for LAMP assay based on a DNA partial sequence in the 18S rRNA gene from S. venezuelensis was designed. The set up LAMP assay (namely, Strong-LAMP) allowed the sensitive detection of S. venezuelensis DNA in both stool and urine samples obtained from each infection group of rats and was also effective in S. stercoralis DNA amplification in patients´ stool samples with previously confirmed strongyloidiasis by parasitological and real-time PCR tests. Conclusions/Significance Our Strong-LAMP assay is an useful molecular tool in research of a strongyloidiasis experimental infection model in both stool and urine samples. After further validation, the Strong-LAMP could also be potentially applied for effective diagnosis of strongyloidiasis in a clinical setting. PMID:27415764
Fernández-Soto, Pedro; Sánchez-Hernández, Alicia; Gandasegui, Javier; Bajo Santos, Cristina; López-Abán, Julio; Saugar, José María; Rodríguez, Esperanza; Vicente, Belén; Muro, Antonio
2016-07-01
Strongyloides stercoralis, the chief causative agent of human strongyloidiasis, is a nematode globally distributed but mainly endemic in tropical and subtropical regions. Chronic infection is often clinically asymptomatic but it can result in severe hyperinfection syndrome or disseminated strongyloidiasis in immunocompromised patients. There is a great diversity of techniques used in diagnosing the disease, but definitive diagnosis is accomplished by parasitological examination of stool samples for morphological identification of parasite. Until now, no molecular method has been tested in urine samples as an alternative to stool samples for diagnosing strongyloidiasis. This study aimed to evaluate the use of a new molecular LAMP assay in a well-established Wistar rat experimental infection model using both stool and, for the first time, urine samples. The LAMP assay was also clinically evaluated in patients´ stool samples. Stool and urine samples were obtained daily during a 28-day period from rats infected subcutaneously with different infective third-stage larvae doses of S. venezuelensis. The dynamics of parasite infection was determined by daily counting the number of eggs per gram of feces from day 1 to 28 post-infection. A set of primers for LAMP assay based on a DNA partial sequence in the 18S rRNA gene from S. venezuelensis was designed. The set up LAMP assay (namely, Strong-LAMP) allowed the sensitive detection of S. venezuelensis DNA in both stool and urine samples obtained from each infection group of rats and was also effective in S. stercoralis DNA amplification in patients´ stool samples with previously confirmed strongyloidiasis by parasitological and real-time PCR tests. Our Strong-LAMP assay is an useful molecular tool in research of a strongyloidiasis experimental infection model in both stool and urine samples. After further validation, the Strong-LAMP could also be potentially applied for effective diagnosis of strongyloidiasis in a clinical setting.
Sullivan, Lauren A; Campbell, Vicki L; Onuma, Serene C
2010-07-15
To determine whether use of a closed urine collection system would decrease the incidence of nosocomial bacteriuria in hospitalized dogs, compared with use of an open urine collection system (used, sterile IV bags). Randomized controlled trial. 51 hospitalized dogs requiring indwelling urinary catheterization for >or= 24 hours. Dogs were randomly assigned to an open or closed urine collection system group. A standardized protocol for catheter placement and maintenance was followed for all dogs. A baseline urine sample was collected via cystocentesis for aerobic bacterial culture, with additional urine samples obtained daily from the urine collection reservoir. 27 dogs were assigned to the open urine collection system group, and 24 were assigned to the closed urine collection system group. The incidence of nosocomial bacteriuria in dogs with open urine collection systems (3/27 [11.1%]) was not significantly different from incidence in dogs with closed urine collection systems (2/24 [8.3%]). Median duration of catheterization was 2 days for dogs in both groups; the range was 1 to 7 days for dogs in the open group and 1 to 5 days for dogs in the closed group. Results suggested that for dogs requiring short-term indwelling urinary catheterization, the type of urine collection system (open vs closed) was not associated with likelihood of developing nosocomial bacteriuria. Use of a strict protocol for urinary catheter placement and maintenance was likely key in the low incidence of nosocomial bacteriuria in the present study.
A new method for quasi-reagent-free biomonitoring of mercury in human urine.
Schlathauer, Maria; Reitsam, Verena; Schierl, Rudolf; Leopold, Kerstin
2017-05-01
A novel analytical method for sampling and extraction of mercury (Hg) from human urine is presented in this work. The method is based on selective accumulation and separation of Hg from fresh urine sample onto active nanogold-coated silica material by highly efficient solid-phase extraction. After thermal desorption of Hg from the extractant, detection is performed by atomic fluorescence spectrometry (AFS). The feasibility and validity of the optimized, quasi-reagent-free approach was confirmed by recovery experiments in spiked real urine (recovery rate 96.13 ± 5.34%) and by comparison of found Hg concentrations in real urine samples - originating from occupationally exposed persons - with values obtained from reference methods cold vapor - atomic absorption spectrometry (CVAAS) and cold vapor - atomic fluorescence spectrometry (CV-AFS). A very good agreement of the found values reveals the validity of the proposed approach. The limit of detection (LOD) was found to be as low as 0.004 μg Hg L -1 and a high reproducibility with a relative standard deviations ≤4.2% (n = 6) is given. Moreover, storage of the samples for up to one week at an ambient temperature of 30 °C reveals no analyte losses or contamination. In conclusion, the proposed method enables easy-to-handle on-site extraction of total Hg from human urine ensuring at the same time reagent-free sample stabilization, providing quick and safe sampling, which can be performed by untrained persons. Copyright © 2017 Elsevier B.V. All rights reserved.
Jain, Raka; Quraishi, Rizwana; Verma, Arpita
2017-01-01
Assessment of cotinine, a metabolite of nicotine in body fluids, is an important approach for validating the self-report among tobacco users. Adaptation of assays on dried urine spots (DUSs) has advantages of ease of collection, transportation, minimal invasiveness, and requirement of small volume. The aim of the present study was to develop an efficient method for testing cotinine in DUSs and evaluating its clinical applicability. This involved optimization of conditions for detection, recovery, and stability of cotinine from dried urine, spotted on filter paper. Enzyme-linked immunosorbent assay was used for screening, whereas confirmation was done by gas chromatography. For clinical applicability, urine samples of tobacco users were tested. Water was found to be a suitable extracting solvent as compared to carbonate-bicarbonate buffer (pH 9.2) and saline. Screening was achieved by two punches taken from a 20 μl (diameter 1.3 cm) spotted urine samples, and confirmation was achieved by five complete circles each of 20 μl sample volume. The recovery was found to be 97% in water. Limit of detection for the method was found to be 100 ng/ml. No signs of significant degradation were found under all storage conditions. All the urine samples of tobacco users were found to be positive by a conventional method as well as DUSs, and the method proved to be efficient. DUS samples are a useful alternative for biological monitoring of recent nicotine use, especially in developing countries where sample logistics could be an important concern.
Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman
2016-01-01
Introduction The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. Materials and methods 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer® Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Results Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Conclusions Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible. PMID:27346967
O'Brien, Kathryn; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C
2013-02-01
Urinary tract infection (UTI) in children may be associated with long-term complications that could be prevented by prompt treatment. To determine the prevalence of UTI in acutely ill children ≤ 5 years presenting in general practice and to explore patterns of presenting symptoms and urine sampling strategies. Prospective observational study with systematic urine sampling, in general practices in Wales, UK. In total, 1003 children were recruited from 13 general practices between March 2008 and July 2010. The prevalence of UTI was determined and multivariable analysis performed to determine the probability of UTI. Out of 597 (60.0%) children who provided urine samples within 2 days, the prevalence of UTI was 5.9% (95% confidence interval [CI] = 4.3% to 8.0%) overall, 7.3% in those < 3 years and 3.2% in 3-5 year olds. Neither a history of fever nor the absence of an alternative source of infection was associated with UTI (P = 0.64; P = 0.69, respectively). The probability of UTI in children aged ≥3 years without increased urinary frequency or dysuria was 2%. The probability of UTI was ≥5% in all other groups. Urine sampling based purely on GP suspicion would have missed 80% of UTIs, while a sampling strategy based on current guidelines would have missed 50%. Approximately 6% of acutely unwell children presenting to UK general practice met the criteria for a laboratory diagnosis of UTI. This higher than previously recognised prior probability of UTI warrants raised awareness of the condition and suggests clinicians should lower their threshold for urine sampling in young children. The absence of fever or presence of an alternative source of infection, as emphasised in current guidelines, may not rule out UTI in young children with adequate certainty.
Measurement of Phenolic Environmental Estrogens in Women with Uterine Leiomyoma
Shen, Yang; Xu, Qian; Ren, Mulan; Feng, Xu; Cai, Yunlang; Gao, Yongxing
2013-01-01
Objectives To investigate the effect of phenolic environmental estrogens on uterine leiomyoma from the perspective of clinical epidemiology. Methods Urine and blood samples were collected from Han women with uterine leiomyoma and women without uterine leiomyoma, living in Nanjing, China, between September 2011 and February 2013. A total of 156 urine samples and 214 blood samples were collected from the uterine leiomyoma group and 106 urine samples and 126 blood plasma samples from the control group. Bisphenol A (BPA), nonylphenol (NP) and octylphenol (OP) concentrations were determined by solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Results Phenolic environmental estrogens in the uterine leiomyoma and control groups were compared based on: gravida>3 and gravida ≤ 3. In participants with gravida>3, urine OP concentration was significantly (P<0.05) higher in the uterine leiomyoma group than in the control group. In participants with gravida ≤ 3, urine NP concentration was significantly (P<0.05) higher in the uterine leiomyoma group compared to controls. Despite obstetric history, urine BPA mean exposure concentration was significantly (P<0.05) different between uterine leiomyoma group and control group. The urine BPA concentration was not significantly (P>0.05) different between gravida>3 and gravida ≤ 3 patients. There was no significant (P>0.05) difference in plasma concentrations of BPA, OP and NP between the leiomyoma group and control group. Mean exposure concentration and range of distribution of BPA, OP and NP plasma concentration differed between the uterine leiomyoma and control group. Conclusion Exposure level of phenolic environmental estrogens in human was related with leiomyoma tumorigenesis. PMID:24255718
Hullegie, Saskia; Wootton, Mandy; Verheij, Theo J M; Thomas-Jones, Emma; Bates, Janine; Hood, Kerenza; Gal, Micaela; Francis, Nick A; Little, Paul; Moore, Michael; Llor, Carl; Pickles, Timothy; Gillespie, David; Kirby, Nigel; Brugman, Curt; Butler, Christopher C
2017-08-01
Urine culture at the point of care minimises delay between obtaining the sample and agar inoculation in a microbiology laboratory, and quantification and sensitivity results can be available more rapidly in primary care. To identify the degree to which clinicians' interpretations of a point-of-care-test (POCT) urine culture (Flexicult™ SSI-Urinary Kit) agrees with laboratory culture in women presenting to primary care with symptoms of uncomplicated urinary tract infections (UTI). Primary care clinicians used the Flexicult™-POCT, recorded their findings and took a photograph of the result, which was interpreted by microbiology laboratory technicians. Urine samples were additionally processed in routine care laboratories. Cross tabulations were used to identify important differences in organism identification, quantification and antibiotic susceptibility between these three sources of data. The influence of various laboratory definitions for UTI on culture were assessed. Primary care clinicians identified 202/289 urine samples (69.9%) as positive for UTI using the Flexicult™-POCT, whereas laboratory culture identified 94-190 (32.5-65.7%) as positive, depending on definition thresholds. 82.9% of samples identified positive for E. coli on laboratory culture were also considered positive for E. coli using the Flexicult™ -POCT, and susceptibilities were reasonably concordant. There were major discrepancies between laboratory staff interpretation of Flexicult™ photographs, clinicians' interpretation of the Flexicult™ test, and laboratory culture results. Flexicult™-POCT overestimated the positivity rate of urine samples for UTI when laboratory culture was used as the reference standard. However, it is unclear whether point-of-care or laboratory based urine culture provides the most valid diagnostic information. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Chatasingh, S; Tapaneya-Olarn, W
1989-01-01
The comparison of specific gravity values of 561 urine samples from TS meter and reagent strip was made. The data were divided into two groups: group 1-less than 2+ protein contained urine samples and group 2--equal or more than 2+ protein contained urine samples. The results revealed that the specific gravity values from both methods in both groups were statistically different (p less than 0.01) but they were correlated at r = 0.84 (p less than 0.001) and r = 0.73 (p less than 0.001) in group 1 and group 2, respectively. It was concluded that the reagent strip is suitable for use as a screening test but it should not be considered when precise measurement is necessary.
Kolbach-Mandel, Ann M; Mandel, Neil S; Hoffmann, Brian R; Kleinman, Jack G; Wesson, Jeffrey A
2017-08-01
Many urine proteins are found in calcium oxalate stones, yet decades of research have failed to define the role of urine proteins in stone formation. This urine proteomic study compares the relative amounts of abundant urine proteins between idiopathic calcium oxalate stone forming and non-stone forming (normal) cohorts to identify differences that might correlate with disease. Random mid-morning urine samples were collected following informed consent from 25 stone formers and 14 normal individuals. Proteins were isolated from urine using ultrafiltration. Urine proteomes for each sample were characterized using label-free spectral counting mass spectrometry, so that urine protein relative abundances could be compared between the two populations. A total of 407 unique proteins were identified with the 38 predominant proteins accounting for >82% of all sample spectral counts. The most highly abundant proteins were equivalent in stone formers and normals, though significant differences were observed in a few moderate abundance proteins (immunoglobulins, transferrin, and epidermal growth factor), accounting for 13 and 10% of the spectral counts, respectively. These proteins contributed to a cationic shift in protein distribution in stone formers compared to normals (22% vs. 18%, p = 0.04). Our data showing only small differences in moderate abundance proteins suggest that no single protein controls stone formation. Observed increases in immunoglobulins and transferrin suggest increased inflammatory activity in stone formers, but cannot distinguish cause from effect in stone formation. The observed cationic shift in protein distribution would diminish protein charge stabilization, which could lead to protein aggregation and increased risk for crystal aggregation.
Shayanfar, Noushin; Tobler, Ulrich; von Eckardstein, Arnold; Bestmann, Lukas
2007-01-01
Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. A total of 332 specimens were collected and analyzed for insoluble urine components by microscopy and automated analyzers, namely the Iris iQ200 (Iris Diagnostics) and the UF-100 flow cytometer (Sysmex). The coefficients of variation for day-to-day quality control of the iQ200 and UF-100 analyzers were 6.5% and 5.5%, respectively, for red blood cells. We reached accuracy ranging from 68% (bacteria) to 97% (yeast) for the iQ200 and from 42% (bacteria) to 93% (yeast) for the UF-100. The combination of dipstick and automated urine sediment analysis increased the sensitivity of screening to approximately 98%. We conclude that automated urine sediment analysis is sufficiently precise and improves the workflow in a routine laboratory. In addition, it allows sediment analysis of all urine samples and thereby helps to detect pathological samples that would have been missed in the conventional two-step procedure according to the European guidelines. Although it is not a substitute for microscopic sediment examination, it can, when combined with dipstick testing, reduce the number of specimens submitted to microscopy. Visual microscopy is still required for some samples, namely, dysmorphic erythrocytes, yeasts, Trichomonas, oval fat bodies, differentiation of casts and certain crystals.
Potential semiochemicals in urine from free ranging wolverines (Gulo gulo Pallas, 1780)
William F. Wood; Jeffrey P. Copeland; Richard E. Yates; Iman K. Horsey; Lynne R. McGreevy
2009-01-01
Urine deposition has been observed as an important scent-marking behaviour among wolverines (Gulo gulo, Mustelinae, Mustelidae). Solid phase microextraction (SPME) of headspace volatiles of the urine from free ranging wolverines were examined by gas chromatography-mass spectrometry (GC-MS). Urine samples were collected directly from the bladder of live-trapped animals...
Krishnan, Shilpa; Karg, Patricia E; Boninger, Michael L; Vodovotz, Yoram; Constantine, Greg; Sowa, Gwendolyn A; Brienza, David M
2016-10-01
To identify changes in concentrations of inflammatory mediators in plasma and urine after traumatic spinal cord injury (SCI) and before the occurrence of a first pressure ulcer. Retrospective; secondary analysis of existing data. Acute hospitalization and inpatient rehabilitation sites at a university medical center. Individuals with a pressure ulcer and plasma samples (n=17) and individuals with a pressure ulcer and urine samples (n=15) were matched by age and plasma/urine sample days to individuals with SCI and no pressure ulcer (N=35). Not applicable. Plasma and urine samples were assayed in patients with SCI, capturing samples within 4 days after the SCI to a week before the formation of the first pressure ulcer. The Wilcoxon signed-rank test was performed to identify changes in the inflammatory mediators between the 2 time points. An increase in concentration of the chemokine interferon-γ-induced protein of 10kd/CXCL10 in plasma (P<.01) and a decrease in concentration of the cytokine interferon-α in urine (P=.01) were observed before occurrence of a first pressure ulcer (∼4d) compared with matched controls. Altered levels of inflammatory mediators in plasma and urine may be associated with pressure ulcer development after traumatic SCI. These inflammatory mediators should be explored as possible biomarkers for identifying individuals at risk for pressure ulcer formation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brima, Eid I.; Haris, Parvez I.; Jenkins, Richard O.
2006-10-01
Very little is known about arsenic (As) metabolism in healthy populations that are not exposed to high concentrations of As in their food or water. Here we present a study with healthy volunteers from three different ethnic groups, residing in Leicester, UK, which reveals statistically significant differences in the levels of total As in urine and fingernail samples. Urine (n = 63), hair (n = 36) and fingernail (n = 36) samples from Asians, Somali Black-Africans and Whites were analysed using inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectroscopy (GF-AAS). The results clearly show that themore » total concentrations of As in urine and fingernail samples of a Somali Black-African population (urine 7.2 {mu}g/g creatinine; fingernails 723.1 {mu}g/kg) are significantly (P < 0.05) different from the Asian (urine 24.5 {mu}g/g creatinine; fingernails 153.9 {mu}g/kg) and White groups (urine 20.9 {mu}g/g creatinine; fingernails 177.0 {mu}g/kg). The chemical speciation of As in the urine of the three groups was also measured using high performance liquid chromatography coupled to ICP-MS. This showed that the proportion of the total urinary As present as dimethylarsenate (DMA) was higher for the Somali Black-African group (50%) compared to the Asians (16%) and Whites (22%). However, there was no significant difference (P > 0.05) in the level of As in the hair samples from these three groups; Somali Black-Africans (116.0 {mu}g/kg), Asians (117.4 {mu}g/kg) and Whites (141.2 {mu}g/kg). Significantly different levels of total As in fingernail and urine and a higher percentage of urinary DMA in the Somali Black-Africans are suggestive of a different pattern of As metabolism in this ethnic group.« less
Schwertner, Harvey A; Kong, Suk Bin
2005-03-09
Modafinil (Provigil) is a new wake-promoting drug that is being used for the management of excessive sleepiness in patients with narcolepsy. It has pharmacological properties similar to that of amphetamine, but without some of the side effects associated with amphetamine-like stimulants. Since modafinil has the potential to be abused, accurate drug-screening methods are needed for its analysis. In this study, we developed a high-performance liquid-chromatographic procedure (HPLC) for the quantitative analysis of modafinil in plasma and urine. (Phenylthio)acetic acid was used as an internal standard for the analysis of both plasma and urine. Modafinil was extracted from urine and plasma with ethyl acetate and ethyl acetate-acetic acid (100:1, v/v), respectively, and analyzed on a C18 reverse phase column with methanol-water-acetic acid (500:500:1, v/v) as the mobile phase. Recoveries from urine and plasma were 80.0 and 98.9%, respectively and the limit of quantitation was 0.1 microg/mL at 233 nm. Forty-eight 2-h post-dose urine samples from sham controls and from individuals taking 200 or 400 mg of modafinil were analyzed without knowledge of drug administration. All 16-placebo urine samples and all 32 2-h post-dose urine samples were correctly classified. The analytical procedure is accurate and reproducible and can be used for therapeutic drug monitoring, pharmacokinetic studies, and drug abuse screening.
NASA Astrophysics Data System (ADS)
Peña Crecente, Rosa M.; Lovera, Carlha Gutiérrez; García, Julia Barciela; Méndez, Jennifer Álvarez; Martín, Sagrario García; Latorre, Carlos Herrero
2014-11-01
The determination of lead in urine is a way of monitoring the chemical exposure to this metal. In the present paper, a new method for the Pb determination by electrothermal atomic absorption spectrometry (ETAAS) in urine at low levels has been developed. Lead was separated from the undesirable urine matrix by means of a solid phase extraction (SPE) procedure. Oxidized multiwalled carbon nanotubes have been used as a sorbent material. Lead from urine was retained at pH 4.0 and was quantitatively eluted using a 0.7 M nitric acid solution and was subsequently measured by ETAAS. The effects of parameters that influence the adsorption-elution process (such as pH, eluent volume and concentration, sampling and elution flow rates) and the atomic spectrometry conditions have been studied by means of different factorial design strategies. Under the optimized conditions, the detection and quantification limits obtained were 0.08 and 0.26 μg Pb L- 1, respectively. The results demonstrate the absence of a urine matrix effect and this is the consequence of the SPE process carried out. Therefore, the developed method is useful for the analysis of Pb at low levels in real samples without the influence of other urine components. The proposed method was applied to the determination of lead in urine samples of unexposed healthy people and satisfactory results were obtained (in the range 3.64-22.9 μg Pb L- 1).
Hughes, D L; Ritter, D J; Wilson, R D
2001-11-01
Method development and validation studies have been completed on an assay that will allow the determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. The accurate determination of 2,4-D in urine is an important factor in monitoring worker and population exposure. These studies successfully validated a method for the detection of 2,4-D in urine at a limit of quantitation (LOQ) of 5.00 ppb (parts per billion) using gas chromatography with mass selective detection (GC/MSD). The first study involved the determination of 2,4-D in control human urine and urine samples fortified with 2,4-D. Due to chromatographic interference, a second study was conducted using 14C-2,4-D to verify the recoverability of 2,4-D from human urine at low levels using the GC/MSD method. The second study supports the results of the original data. The 2,4-D was extracted from human urine using a procedure involving hydrolysis using potassium hydroxide, followed by a liquid-liquid extraction into methylene chloride. The extracted samples were derivatized with diazomethane. The methylated fraction was analyzed by GC/MSD. Quantitation was made by comparison to methylated reference standards of 2,4-D. Aliquots fortified at 5-, 50-, and 500-ppb levels were analyzed. The overall mean recovery for all fortified samples was 90.3% with a relative standard deviation of 14.31%.
The International Space Station Urine Monitoring System (UMS)
NASA Technical Reports Server (NTRS)
Feeback, Daniel L.; Cibuzar, Branelle R.; Milstead, Jeffery R.; Pietrzyk,, Robert A.; Clark, Mark S.F.
2009-01-01
A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification completed prior to placing the instrument into operation. Samples collected during the verification sequence will be returned for analyses on STS-131 (19A) currently scheduled for launch in March 2010. The presence of a UMS on ISS will provide the capability to conduct additional collaborative human life science investigations among the ISS International Partners.
Zakrzewski, Robert; Ciesielski, Witold
2005-09-25
The reaction between iodine and azide ions induced by thiopental was utilized as a postcolumn reaction for chromatographic determination of thiopental. The method is based on the separation of thiopental on an Nova-Pak CN HP column with an acetonitrile-aqueous solution of sodium azide as a mobile phase, followed by spectrophotometric measurement of the residual iodine (lambda=350 nm) from the postcolumn iodine-azide reaction induced by thiopental after mixing an iodine solution containing iodide ions with the column effluent containing azide ions and thiopental. Chromatograms obtained for thiopental showed negative peaks as a result of the decrease in background absorbance. The detection limit (defined as S/N=3) was 20 nM (0.4 pmol injected amount) for thiopental. Calibration graphs, plotted as peak area versus concentrations, were linear from 40 nM. The elaborated method was applied to determine thiopental in urine samples. The detection limit (defined as S/N=3) was 0.025 nmol/ml urine. Calibration graphs, plotted as peak area versus concentrations, were linear from 0.05 nmol/ml urine. Authentic urine samples were analyzed, thiopental was determined at nmol/ml urine level.
Kazubek-Zemke, Maja; Rybka, Jacek; Marchewka, Zofia; Rybka, Wojciech; Pawlik, Krzysztof; Długosz, Anna
2014-11-14
The early diagnosis of the nephrotoxic effect of xenobiotics and drugs is still an unsolved problem. Recent studies suggest a correlation between the nephrotoxic activity of xenobiotics and increased concentration of amino acids in urine. The presented study was focused on the application of GLC-MS method for amino acids profiling in human urine as a noninvasive method for monitoring of kidney condition and tubular injury level. The analytic method is based on the conversion of the amino acids present in the sample to tert-butyldimethylsilyl (TBDMS) derivatives and their analysis by gas-liquid chromatography-mass spectrometry (GLC-MS). The procedure of urine sample preparation for chromatographic analysis was optimized. The presence of 12 amino acids in most of the tested healthy human urine samples was detected. The significant differences in the levels of particular amino acids between patients with tubular injury and healthy controls were found, especially for lysine, valine, serine, alanine and leucine (on average 30.0, 7.5, 3.6, 2.9 and 0.5 fold respectively). We found that this approach based on GLC-MS detection can be used in nephrotoxicity studies for urine amino acids monitoring in exposure to xenobiotics and drugs.
Detection and quantification of rituximab in the human urine.
Jacobs, Roland; Langer-Jacobus, Thais; Duong, Michelle; Stahl, Klaus; Haller, Hermann; Schmidt, Reinhold E; Schiffer, Mario
2017-12-01
B cell depletion by rituximab treatment might be inefficient in patients suffering from nephrotic syndrome. Due to the impaired glomerular filtration barrier a significant portion of the therapeutic antibody might be lost into the urinary space. In order to determine the amount of rituximab in the urine of such patients, CD20+ Daudi cells were stained with the patients' urine followed by a fluorochrome-labeled secondary antibody. Mean fluorescence intensity of that way labeled Daudi cells was determined by flow cytometry. Control samples with defined rituximab concentrations were used to create standard curves. The analyses revealed that all nephelometric IgG+ urine samples tested also manifested rituximab at concentrations between 100 and 46,707μg/L. The flow cytometry-based approach is an easy and reliable method to assess rituximab in patients' urine samples for monitoring individual rituximab treatment courses in all patients co-presenting impaired renal filtration. Presence of such antibodies in the urine could be considered as criteria to modify the formulation or modality of rituximab delivery in order to prevent the loss of the therapeutic antibodies and thereby ensuring efficacy of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.
Wu, Hon-Yen; Peng, Yu-Sen; Chiang, Chih-Kang; Huang, Jenq-Wen; Hung, Kuan-Yu; Wu, Kwan-Dun; Tu, Yu-Kang; Chien, Kuo-Liong
2014-07-01
A random urine sample measuring the albumin concentration (UAC) without simultaneously measuring the urinary creatinine is less expensive than measuring the ratio of albumin to creatinine (ACR), but comparisons of their diagnostic performance for microalbuminuria screening among patients with diabetes mellitus (DM) have not been undertaken in previous meta-analyses. To compare the diagnostic performance of the UAC vs the ACR in random urine samples for microalbuminuria screening among patients with DM. Electronic literature searches of PubMed, MEDLINE, and Scopus for English-language publications from the earliest available date of indexing through July 31, 2012. Clinical studies assessing the UAC or the ACR of random urine samples in detecting the presence of microalbuminuria among patients with DM using a urinary albumin excretion rate of 30 to 300 mg/d in 24-hour timed urine collections as the criterion standard. Bivariate random-effects models for analysis and pooling of the diagnostic performance measures across studies, as well as comparisons between different screening tests. The primary end point was the diagnostic performance measures of the UAC or the ACR in random urine samples, as well as comparisons between them. We identified 14 studies, with a total of 2078 patients; 9 studies reported on the UAC, and 12 studies reported on the ACR. Meta-analysis showed pooled sensitivities of 0.85 and 0.87 for the UAC and the ACR, respectively, and pooled specificities of 0.88 and 0.88, respectively. No differences in sensitivity (P = .70), specificity (P = .63), or diagnostic odds ratios (P = .59) between the UAC and the ACR were found. The time point of urine collection did not affect the diagnostic performance of either test. The UAC and the ACR yielded high sensitivity and specificity for the detection of microalbuminuria. Because the diagnostic performance of the UAC is comparable to that of the ACR, our findings indicate that the UAC of random urine samples may become the screening tool of choice for the population with DM, considering the rising incidence of DM and the constrained health care resources in many countries.
Mercadante, Rosa; Polledri, Elisa; Bertazzi, Pier Alberto; Fustinoni, Silvia
2013-10-01
The aim of this work was to evaluate short-term and long-term exposure to terbuthylazine (TBA) in agriculture workers (AW), rural residents (RR), and urban residents (UR) using urine and hair specimens. Twelve AW, 13 RR, and 17 UR were included in the study. Urine spot samples were collected with two different protocols. AW urine samples were collected before the application season (February, U0), at bedtime on the day of TBA application (March-May, U1), and prior to the next shift on the day after TBA application (U2). RR and UR urine samples were collected on any day during the application season (Ue). Hair samples were collected for all subjects before the application season (February, H0) and at the end of the season (June, H1). TBA and its metabolite desethylterbuthylazine (DET) were measured by liquid chromatography coupled with triple quadrupole mass spectrometry detection. DET was exclusively found in urine, while TBA was mostly found in the hair. In the AW, the urinary levels of DET were not detected in the U0 samples, and they increased to median levels of 1.81 and 2.94μg/L in the U1 and U2 samples, respectively (p<0.001). In the RR and UR, DET was not detected in the Ue samples. In the UR, TBA was not detected in the H0 samples, and the median levels of TBA were 0.01ng/mg hair in both the AW and RR. In the H1 samples, the median TBA levels were not detected, 0.01, and 0.08ng/mg hair in the UR, RR, and AW, respectively (p<0.001). Urinary DET and hair TBA are promising candidates for biomonitoring short- and long-term exposure to TBA. The use of this herbicide in agriculture leads to exposure in rural residents. © 2013.
Rossi, Gabriele; Giori, Luca; Campagnola, Simona; Zatelli, Andrea; Zini, Eric; Paltrinieri, Saverio
2012-06-01
To determine whether preanalytic and analytic factors affect evaluation of the urinary protein-to-creatinine (UPC) ratio in dogs. 50 canine urine samples. The UPC ratio was measured to assess the intra-assay imprecision (20 measurements within a single session), the influence of predilution (1:10, 1:20, and 1:100) for urine creatinine concentration measurement, and the effect of storage at room temperature (approx 20°C), 4°C, and -20°C. The coefficient of variation at room temperature determined with the 1:20 predilution was < 10.0%, with the highest coefficients of variation found in samples with a low protein concentration or low urine specific gravity. This variability could result in misclassification of samples with UPC ratios close to the thresholds defined by the International Renal Interest Society to classify dogs as nonproteinuric (0.2), borderline proteinuric (0.21 to 0.50), or proteinuric (> 0.51). A proportional bias was found in samples prediluted 1:10, compared with samples prediluted 1:20 or 1:100. At room temperature, the UPC ratio did not significantly increase after 2 and 4 hours. After 12 hours at room temperature and at 4°C, the UPC ratio significantly increased. The UPC ratio did not significantly change during 3 months of storage at -20°C. The intra-assay precision of the UPC ratio was sufficiently low to avoid misclassification of samples, except for values close to 0.2 or 0.5. The optimal predilution ratio for urine creatinine concentration measurement was 1:20. A 1:100 predilution is recommended in samples with a urine specific gravity > 1.030. The UPC ratio must be measured as soon as samples are collected. Alternatively, samples should be immediately frozen to increase their stability and minimize the risk of misclassification of proteinuria.
Uralets, Victor; App, Mike; Rana, Sumandeep; Morgan, Stewart; Ross, Wayne
2014-03-01
2-Ethylamino-1-phenylbutane (EAPB) and 2-amino-1-phenylbutane (APB) were identified by gas chromatography-mass spectrometry in multiple urine samples submitted for stimulant drug testing and screened positive for amphetamines by enzyme immunoassay. Forty-two samples from all over the USA were found, containing both analytes during a 3-month period May-July 2013. A sports dietary supplement 'CRAZE' has been determined to be one of the sources of EAPB supply. EAPB along with its suggested metabolite APB were detected in a urine sample, obtained from a person known to use 'CRAZE'.
Zhang, Su-jing; Luo, Ru-xin; Ma, Dong; Zhuo, Xian-yi
2016-04-01
To determine the normal reference values of 33 elements, Ag, Al, As, Au, B, Ba, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, Hg, Li, Mg, Mn, Mo, Ni, Pb, Rb, Sb, Se, Sr, Th, Ti, Tl, U, V, Zn and Zr, in the blood and urine samples from the general population in Sanmen County of Zhejiang province, a typical coastal area of eastern China. The 33 elements in 272 blood and 300 urine samples were determined by inductively coupled plasma-mass spectrometry (ICP-MS). The normality test of data was conducted using SPSS 17.0 Statistics. The data was compared with other reports. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County were obtained, which of some elements were found to be similar with other reports, such as Co, Cu, Mn and Sr, while As, Cd, Hg and Pb were generally found to be higher than those previously reported. There was a wide variation between the reports from different countries in blood Ba. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County are established, and successfully applied to two poisoning cases.
Huang, Rongfu; Han, Sungyub; Li, Xiao Sheryl
2013-08-01
The nicotine metabolites, cotinine and trans-3'-hydroxycotinine (3HC) are considered as superior biomarkers for identifying tobacco exposure. More importantly, the ratio of 3HC to cotinine is a good indicator to phenotype individuals for cytochrome P450 2A6 activity and to individualize pharmacotherapy for tobacco addiction. In this paper, a simple, robust and novel method based on surface-enhanced Raman spectroscopy coupled with thin-layer chromatography (TLC) was developed to directly quantify the biomarkers in human urine samples. This is the first time surface-enhanced Raman spectroscopy (SERS) was used to detect cotinine and 3HC in urine samples. The linear dynamic range for the detection of cotinine is from 40 nM to 8 μM while that of 3HC is from 1 μM to 15 μM. The detection limits are 10 nM and 0.2 μM for cotinine and 3HC, respectively. The proposed method was further validated by quantifying the concentration of both cotinine and 3HC in smokers' urine samples. This TLC-SERS method allows the direct detection of cotinine in the urine samples of both active and passive smokers and the detection of 3HC in smokers.
Smartphone-based, sensitive µPAD detection of urinary tract infection and gonorrhea.
Cho, Soohee; Park, Tu San; Nahapetian, Tigran G; Yoon, Jeong-Yeol
2015-12-15
The presence of bacteria in urine can be used to monitor the onset or prognosis of urinary tract infection (UTI) and some sexually-transmitted diseases (STDs), such as gonorrhea. Typically, bacteria's presence in urine is confirmed by culturing samples overnight on agar plates, followed by a microscopic examination. Additionally, the presence of Escherichia coli in a urine sample can be indirectly confirmed through assaying for nitrite (generated by reducing nitrate in urine), however this is not sufficiently specific and sensitive. Species/strains identification of bacteria in a urine sample provides insight to appropriate antibiotic treatment options. In this work, a microfluidic paper analytical device (µPAD) was designed and fabricated for evaluating UTI (E. coli) and STD (Neisseria gonorrhoeae) from human urine samples. Anti-E. coli or anti-N. gonorrhoeae antibodies were conjugated to submicron particles then pre-loaded and dried in the center of each paper microfluidic channel. Human urine samples (undiluted) spiked with E. coli or N. gonorrhoeae were incubated for 5 min with 1% Tween 80. The bacteria-spiked urine samples were then introduced to the inlet of paper microfluidic channel, which flowed through the channel by capillary force. Data confirms that proteins were not filtered by μPAD, which is essential for this assay. Urobilin, the component responsible for the yellow appearance of urine and green fluorescence emission, was filtered by μPAD, resulting in significantly minimized false-positive signals. This filtration was simultaneously made during the μPAD assay and no pretreatment/purification step was necessary. Antibody-conjugated particles were immunoagglutinated at the center of the paper channel. The extent of immunoagglutination was quantified by angle-specific Mie scatter under ambient lighting conditions, utilizing a smartphone camera as a detector. The total μPAD assay time was less than 30s. The detection limit was 10 CFU/mL for both E. coli and N. gonorrhoeae, while commercially available gonorrhea rapid kit showed a detection limit of 10(6) CFU/mL. A commercially available nitrite assay test strip also had a detection limit of 10(6) CFU/mL, but this method is not antibody-based and thus not sufficiently specific. By optimizing the particle concentration, we were also able to extend the linear range of the assay up to 10(7) CFU/mL. The proposed prototype will serve as a low-cost, point-of-care, sensitive urinalysis biosensor to monitor UTI and gonorrhea from human urine. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yi-Xin; Zeng, Qiang; Wang, Le
Urinary haloacetic acids (HAAs), such as dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA), have been suggested as potential biomarkers of exposure to drinking water disinfection byproducts (DBPs). However, variable exposure to and the short elimination half-lives of these biomarkers can result in considerable variability in urinary measurements, leading to exposure misclassification. Here we examined the variability of DCAA and TCAA levels in the urine among eleven men who provided urine samples on 8 days over 3 months. The urinary concentrations of DCAA and TCAA were measured by gas chromatography coupled with electron capture detection. We calculated the intraclass correlation coefficientsmore » (ICCs) to characterize the within-person and between-person variances and computed the sensitivity and specificity to assess how well single or multiple urine collections accurately determined personal 3-month average DCAA and TCAA levels. The within-person variance was much higher than the between-person variance for all three sample types (spot, first morning, and 24-h urine samples) for DCAA (ICC=0.08–0.37) and TCAA (ICC=0.09–0.23), regardless of the sampling interval. A single-spot urinary sample predicted high (top 33%) 3-month average DCAA and TCAA levels with high specificity (0.79 and 0.78, respectively) but relatively low sensitivity (0.47 and 0.50, respectively). Collecting two or three urine samples from each participant improved the classification. The poor reproducibility of the measured urinary DCAA and TCAA concentrations indicate that a single measurement may not accurately reflect individual long-term exposure. Collection of multiple urine samples from one person is an option for reducing exposure classification errors in studies exploring the effects of DBP exposure on reproductive health. - Highlights: • We evaluated the variability of DCAA and TCAA levels in the urine among men. • Urinary DCAA and TCAA levels varied greatly over a 3-month period. • Single measurement may not accurately reflect personal long-term exposure levels. • Collecting multiple samples from one person improved the exposure classification.« less
Bader, Michael; Messerer, Peter; Will, Wolfgang
2013-08-01
Urinary creatinine is an important parameter for the adjustment of metabolite concentrations in differently diluted urine specimens, as a reference dimension for biological limit or guidance values and as a selection criterion for spot urine samples in human biomonitoring. While the creatinine output of the general population has been well described in environmental surveys, this study focused specifically on creatinine concentrations in a large industrial workforce in order to compare these data with the general population and to provide a database for the calculation of a reasonable conversion factor between volume-related and creatinine-adjusted data and vice versa. Urinary creatinine was analysed in 6,438 spot urine samples by a photometric assay in the time period between 1989 and 2009. Basic demographic data (age, sex, body weight, body height) and job category (apprentices, skilled craftsmen, skilled chemical workers, foremen, laboratory staff and executives) were considered in a statistical analysis. The median concentration of urinary creatinine in all urine samples was 1.36 g/L with male employees showing significantly higher values (1.37 g/L, n = 6,148 samples) than female employees (1.00 g/L, n = 290) and concentrations ranging from 0.01 up to 9.76 g/L. Age, body mass index and job category were significant influence factors on urinary creatinine. About 92 % of all samples showed creatinine concentrations between 0.3 and 3.0 g/L, a range recommended by the World Health Organization as a criterion for valid spot urine samples. The results of this study correspond well with data from environmental surveys and with recent data from an active workforce in industry with similar sampling strategies. Therefore, a median of 1.4 g creatinine per litre urine seems to be a reasonable value for general calculations and adjustments. The study data also support the validity of the current recommendations by the WHO and several scientific committees and institutions with respect to creatinine limits in spot urine samples for occupational-medical biomonitoring.
Peng, Jun; Guo, Kevin; Xia, Jianguo; Zhou, Jianjun; Yang, Jing; Westaway, David; Wishart, David S; Li, Liang
2014-10-03
Because of a limited volume of urine that can be collected from a mouse, it is very difficult to apply the common strategy of using multiple analytical techniques to analyze the metabolites to increase the metabolome coverage for mouse urine metabolomics. We report an enabling method based on differential isotope labeling liquid chromatography mass spectrometry (LC-MS) for relative quantification of over 950 putative metabolites using 20 μL of urine as the starting material. The workflow involves aliquoting 10 μL of an individual urine sample for ¹²C-dansylation labeling that target amines and phenols. Another 10 μL of aliquot was taken from each sample to generate a pooled sample that was subjected to ¹³C-dansylation labeling. The ¹²C-labeled individual sample was mixed with an equal volume of the ¹³C-labeled pooled sample. The mixture was then analyzed by LC-MS to generate information on metabolite concentration differences among different individual samples. The interday repeatability for the LC-MS runs was assessed, and the median relative standard deviation over 4 days was 5.0%. This workflow was then applied to a metabolomic biomarker discovery study using urine samples obtained from the TgCRND8 mouse model of early onset familial Alzheimer's disease (FAD) throughout the course of their pathological deposition of beta amyloid (Aβ). It was showed that there was a distinct metabolomic separation between the AD prone mice and the wild type (control) group. As early as 15-17 weeks of age (presymptomatic), metabolomic differences were observed between the two groups, and after the age of 25 weeks the metabolomic alterations became more pronounced. The metabolomic changes at different ages corroborated well with the phenotype changes in this transgenic mice model. Several useful candidate biomarkers including methionine, desaminotyrosine, taurine, N1-acetylspermidine, and 5-hydroxyindoleacetic acid were identified. Some of them were found in previous metabolomics studies in human cerebrospinal fluid or blood samples. This work illustrates the utility of this isotope labeling LC-MS method for biomarker discovery using mouse urine metabolomics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raml, Reingard; Rumpler, Alice; Goessler, Walter
2007-08-01
Over the last 6 years, much work on arsenic species in urine samples has been directed toward the determination of the reduced dimethylated arsenic species, DMA(III), because of its high toxicity and perceived key role in the metabolism of inorganic arsenic. Recent work, however, has suggested that DMA(III) may at times have been misidentified because its chromatographic properties can be similar to those of thio-dimethylarsinate (thio-DMA). We analyzed by HPLC-ICPMS (inductively coupled plasma mass spectrometry) urine samples from 75 arsenic-exposed women from Bangladesh with total arsenic concentrations ranging from 8 to 1034 {mu}g As/L and found that thio-DMA was presentmore » in 44% of the samples at concentrations ranging mostly from trace amounts to 24 {mu}g As/L (one sample contained 123 {mu}g As/L). Cytotoxicity testing with HepG2 cells derived from human hepatocarcinoma indicated that thio-DMA was about 10-fold more cytotoxic than dimethylarsinate (DMA). The widespread occurrence of thio-DMA in urine from these arsenic-exposed women suggests that this arsenical may also be present in other urine samples and has so far escaped detection. The work highlights the need for analytical methods providing specific determinations of arsenic compounds in future studies on arsenic metabolism and toxicology.« less
Breier, Ana Carolina; Cé, Jaqueline; Coelho, Janice Carneiro
2014-06-10
Mucopolysaccharidoses (MPSs) are a group of lysosomal storage diseases caused by the deficiency/absence of enzymes which catalyze the degradation of glycosaminoglycans (GAGs). The use of biological samples dried on filter paper has been increasing because it makes it easy to ship them to reference laboratories. Urinary GAGs are the main biomarkers of MPS and, thus, we studied the correlations of determinations to GAGs and creatinine, as well as compared the GAGs' profile on electrophoresis, between urine and dried urine in filter paper (DUFP) samples. We also assessed the GAG stability over time under different storage temperatures. We quantified the GAG concentration in both sample types and compared the results by Pearson correlation. The results were very similar, with r=0.97 for creatinine and with r=0.94 and r=0.98 for GAGs for controls and patients, respectively, with similar electrophoretic profiles. The GAG stability in DUFP was up to 30days at -20, 4, and 25°C and up to 21days at 37°C. Our proposal assessed urinary GAGs in DUFP and concluded that these samples can be used in the investigation of MPS, replacing urine samples in neonatal screening and monitoring of therapies, due to ease of transportation and storage. Copyright © 2014 Elsevier B.V. All rights reserved.
Saukkoriipi, Annika; Pascal, Thierry; Palmu, Arto A
2016-02-01
We evaluated the BinaxNOW® urine antigen test in elderly. For fresh un-concentrated urine samples, the sensitivity for pneumococcal pneumonia was 63% and specificity 97%. After freezing and concentration, the results comparable to positive control line in intensity at 60 min gave high sensitivity (81%) with no loss in specificity (96%). Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Shaohua; Wang, Lan; Chen, Weiwei; Lin, Duo; Huang, Lingling; Wu, Shanshan; Feng, Shangyuan; Chen, Rong
2014-09-01
A surface-enhanced Raman spectroscopy (SERS) approach was utilized for urine biochemical analysis with the aim to develop a label-free and non-invasive optical diagnostic method for esophagus cancer detection. SERS spectrums were acquired from 31 normal urine samples and 47 malignant esophagus cancer (EC) urine samples. Tentative assignments of urine SERS bands demonstrated esophagus cancer specific changes, including an increase in the relative amounts of urea and a decrease in the percentage of uric acid in the urine of normal compared with EC. The empirical algorithm integrated with linear discriminant analysis (LDA) were employed to identify some important urine SERS bands for differentiation between healthy subjects and EC urine. The empirical diagnostic approach based on the ratio of the SERS peak intensity at 527 to 1002 cm-1 and 725 to 1002 cm-1 coupled with LDA yielded a diagnostic sensitivity of 72.3% and specificity of 96.8%, respectively. The area under the receive operating characteristic (ROC) curve was 0.954, which further evaluate the performance of the diagnostic algorithm based on the ratio of the SERS peak intensity combined with LDA analysis. This work demonstrated that the urine SERS spectra associated with empirical algorithm has potential for noninvasive diagnosis of esophagus cancer.
Determination of Deoxynivalenol in the Urine of Pregnant Women in the UK
Wells, Liz; Hardie, Laura; Williams, Courtney; White, Kay; Liu, Yunru; De Santis, Barbara; Debegnach, Francesca; Moretti, Georgio; Greetham, Stephanie; Brera, Carlo; Rigby, Alan; Atkin, Stephen; Sathyapalan, Thozhukat
2016-01-01
Deoxynivalenol (DON) is one of the most commonly occurring trichothecenes, produced mainly by Fusarium graminearum. Little is known about the effect of DON exposure or the levels of DON exposure that occur during pregnancy. The project aimed to provide data on levels of total DON and de-epoxi Deoxynivalenol (DOM-1) in pregnant human urine samples analysed by liquid chromatography-mass spectrometry (LC-MS). Morning urine samples were collected over two consecutive days from 42 volunteers and associated food consumption was recorded for the 24 h prior to the sample. Spearman’s rho non-parametric test for correlation was used to assess the data. Levels of DON did not differ significantly between day 1 (mean 29.7 ng/mL urine or 40.1 ng DON/mg creatinine) and day 2 (mean 28.7 ng/mL urine or 38.8 ng DON/mg creatinine ng/mL/day) urine samples. The only significant positive correlation was found between total ng DON/mg creatinine and parity (rho = 0.307, n = 42, p < 0.005 two-tailed) and total ng DON/mg creatinine with baked goods on day 1 (rho = 0.532, n = 42, p < 0.0005 two-tailed). This study provides data on the DON levels in pregnancy in this suburban population and reassurance that those levels are within acceptable limits. PMID:27792137
Mutagenic activity and metabolites in the urine of workers exposed to trinitrotoluene (TNT).
Ahlborg, G; Einistö, P; Sorsa, M
1988-01-01
Urine samples taken after work and after a free weekend from 50 workers employed in various activities in a chemical plant manufacturing explosives were analysed. On the basis of hygienic surveys, the subjects were divided into three categories of exposure to trinitrotoluene (TNT). The urine analyses consisted of gas chromatographic identification of TNT and its two metabolites, 4-ADNT and 2-ADNT, and a determination of the mutagenic activity. Two frame shift detector strains of Salmonella typhimurium were used, TA 98 and TA 98 NR, the latter being deficient in endogenous nitroreductase activity. On the basis of previous results on TNT mutagenicity, no exogeneous metabolic system was used to test the urine concentrates. Both tester strains showed that the mean urinary mutagenic activity was higher in the after work samples than in post weekend samples from the same subjects, showing that bacterial nitroreductase activity was not significantly responsible for the mutagenicity, although the response was higher with strain TA 98 than with TA 98 NR. The interindividual variation in urine mutagenicity was high, however, and the difference between the two sampling times was statistically significant (p less than 0.05) only for the high exposed group (workers in trotyl foundry and sieve house). Correlation between urinary mutagenicity and concentration of TNT in urine was poor; correlation was significant only with the urinary concentration of 4-ADNT. The correlation between urinary TNT and both metabolites was good (p less than 0.001). These results suggest that analysis of 4-ADNT in urine would be a sufficient biological measure for controlling exposure to TNT. PMID:3378017
Unmetabolized VOCs in urine as biomarkers of low level occupational exposure.
Janasik, Beata; Jakubowski, Marek; Wesołowski, Wiktor; Kucharska, Małgorzata
2010-01-01
To compare the usefulness of determining unchanged forms of volatile organic compounds (VOCs), namely toluene (TOL), ethylbenzene (EB) and xylene (XYL), in urine with the effectiveness of the already used biomarkers of occupational exposure. Surveys were conducted in two workplaces (paint factory and footwear factory). In total, 65 subjects participated in the study. Air samples were collected using individual samplers during work shift. Urine and blood samples were collected at the end of work shift. Urine samples were analyzed for unchanged compounds and selected metabolites, while blood samples were tested for unchanged compounds. VOCs in blood and urine were determined by solid phase microextraction gas chromatography (SPME-GC-MS). In the paint factory, the geometric mean (GM) concentrations of VOCs in the air ranged as follows: 0.2-4.7 mg/m(3) for TOL, 0.4-40.9 mg/m(3) for EB and 0.1-122.6 mg/m(3) for XYL. In the footwear factory, the GM concentration of TOL in the air amounted to 105.4 mg/m(3). A significant correlation (p < 0.05) was observed between VOCs in blood, urine and air. The regression analyses performed for paint factory workers showed that TOL-U and TOL-B were better biomarkers of exposure (r = 0.72 and r = 0.81) than benzoic acid (r = 0.12) or o-cresol (r = 0.55). The findings of the study point out that the concentration of unchanged VOCs in urine can be a reliable biological indicator of low level occupational exposure to these compounds.
Wang, Zhi; Shi, Zongwei; Xi, Cunxian; Wang, Guomin; Cao, Shurui; Zhang, Lei; Tang, Bobin; Mu, Zhaode
2017-12-01
An analytical method was established for the rapid detection of antibiotic growth promoters (AGPs) in bovine muscle, and bovine blood and bovine urine, using ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). After the addition of an aqueous solution of EDTA-Na 2 , the pH of bovine urine samples was directly adjusted to 5.2 by acetic acid-ammonium acetate and purified by HLB solid-phase extraction cartridge; bovine muscle and bovine blood samples processing were extracted with acetonitrile (ACN) and ACNwater (90:10; v/v) without any purification step. The samples were then centrifuged, concentrated and analysed by UPLC-MS/MS on an ACQUITY UPLC® BEH C18 column using gradient elution. The developed method was validated and mean recovery percentages at three spiked levels were 74-119%, 76-115% and 76-119%, respectively, in bovine muscle, bovine blood, and bovine urine. The relative standard deviation (RSD) ranged from 1.0% to 14.7% in spiked bovine muscle, bovine blood and bovine urine. The limits of detection (LOD) of all analytes were in the ranges 0.11-3.82 µg kg -1 , 0.10-2.49 µg kg -1 and 0.06-4.53 µg kg -1 in bovine muscle, bovine blood, and bovine urine, respectively. The method was sensitive, accurate and was applied to monitor real samples. To the best of our knowledge, this is first method available for simultaneous determination of several classes of APGs in bovine muscle, and bovine blood and bovine urine.
Seasonal variation in natural abundance of 2H and 18O in urine samples from rural Nigeria.
Harbison, Justin E; Dugas, Lara R; Brieger, William; Tayo, Bamidele O; Alabi, Tunrayo; Schoeller, Dale A; Luke, Amy
2015-07-01
The doubly labeled water (DLW) method is used to measure free-living energy expenditure in humans. Inherent to this technique is the assumption that natural abundances of stable isotopes (2)H and (18)O in body water remain constant over the course of the measurement period and after elimination of the loading dose of DLW will return to the same predose level. To determine variability in the natural abundances of (2)H and (18)O in humans living in a region with seasonal shifts in rain patterns and sources of drinking water, over the course of 12 mo we collected weekly urine samples from four individuals living in southwest Nigeria as well as samples of their drinking water. From ongoing regional studies of hypertension, obesity, and energy expenditure, we estimated average water turnover rate, urine volumes, and sodium and potassium excretion. Results suggest that (2)H and (18)O in urine, mean concentrations of urinary sodium and potassium, urine volume, and total body turnover differed significantly from dry to rainy season. Additionally, seasonal weather variables (mean monthly maximum temperatures, total monthly rainfall, and minimum relative humidity) were all significantly associated with natural abundances in urine. No seasonal difference was observed in drinking water samples. Findings suggest that natural abundances in urine may not remain constant as assumed, and studies incorporating DLW measurements across the transition of seasons should interpret results with caution unless appropriate doses of the tracers are used. Copyright © 2015 the American Physiological Society.
Modulated Raman spectroscopy for enhanced identification of bladder tumor cells in urine samples.
Canetta, Elisabetta; Mazilu, Michael; De Luca, Anna Chiara; Carruthers, Antonia E; Dholakia, Kishan; Neilson, Sam; Sargeant, Harry; Briscoe, Tina; Herrington, C Simon; Riches, Andrew C
2011-03-01
Standard Raman spectroscopy (SRS) is a noninvasive technique that is used in the biomedical field to discriminate between normal and cancer cells. However, the presence of a strong fluorescence background detracts from the use of SRS in real-time clinical applications. Recently, we have reported a novel modulated Raman spectroscopy (MRS) technique to extract the Raman spectra from the background. In this paper, we present the first application of MRS to the identification of human urothelial cells (SV-HUC-1) and bladder cancer cells (MGH) in urine samples. These results are compared to those obtained by SRS. Classification using the principal component analysis clearly shows that MRS allows discrimination between Raman spectra of SV-HUC-1 and MGH cells with high sensitivity (98%) and specificity (95%). MRS is also used to distinguish between SV-HUC-1 and MGH cells after exposure to urine for up to 6 h. We observe a marked change in the MRS of SV-HUC-1 and MGH cells with time in urine, indicating that the conditions of sample collection will be important for the application of this methodology to clinical urine samples.
Biomonitoring of trace elements in urine samples of children from a coal-mining region.
Santos, Marina Dos; Flores Soares, Maria Cristina; Martins Baisch, Paulo Roberto; Muccillo Baisch, Ana Luíza; Rodrigues da Silva Júnior, Flavio Manoel
2018-04-01
Biomonitoring through urine samples is important for evaluating environmental exposure, since urine is the main form of excretion for most chemical elements. Children are considered more vulnerable to adverse environmental conditions, especially children in developing countries. This study aimed to biomonitor trace elements in urine samples in children from a coal-mining region in the extreme south of Brazil. A cross-sectional study was conducted on 96 children between 6 and 11 years of age. Socioeconomic data and urine samples were collected to estimate the concentration of iron, zinc, selenium, lead, and cadmium. The prevalence of metals above the reference values was 52.0% for Se, followed by 15.6% for Zn. The data point toward a vulnerability to adverse environmental conditions in these children. Although the concentrations of the elements did not reveal intoxication cases, biomonitoring should be carried out continuously in order to assess exposure to metals and ensure the health of the population. This article provides data that help determine natural levels of metallic elements in children, specifically in South America, which have not yet been established. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola
2011-04-01
(1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.
Liou, Saou-Hsing; Yang, Gordon C C; Wang, Chih-Lung; Chiu, Yu-Han
2014-07-30
This 5-month study contains two parts: (1) to monitor the concentrations of 11 phthalate esters metabolites (PAEMs) and two beta-agonists in human urine samples collected from a small group of consented participants including 16 females and five males; and (2) to analyze the residues of phthalate esters (PAEs) and beta-agonists in various categories of drinking water consumed by the same group of subjects. Each category of human urine and drinking water had 183 samples of its own. The analytical results showed that nine PAEMs were detected in human urine and eight PAEs were detected in drinking water samples. It was found that average concentrations of PAEMs increased as the age increased, but no significant difference between sexes. Further, using the principal component analysis, the loadings of age effect were found to be two times greater than that of gender effect in terms of four DEHP metabolites. Regarding beta-agonists of concern (i.e., ractopamine and salbutamol), they were neither detected in human urine nor drinking water samples in this study. Copyright © 2014 Elsevier B.V. All rights reserved.
The purpose of this SOP is to describe the procedures for collection, storage, and shipment of urine samples for metal, pesticides, and creatinine analysis. Samples were collected on Days 2 and 8 of each Cycle. The Day 2 sample was analyzed for metals and creatinine. The Day 8...
Mass Spectrometric Rapid Diagnosis of Infectious Diseases.
1980-01-01
the analytical procedures to warrant reporting anew the whole analytical procedure. A. Sample Collection and Storage Procedure Urine samples were...positives or false-negatives. Next we have carried out a longitudinal study on urine samples obtained from groups of volunteer subjects vaccinated with...sterilization and storage procedures. 2. Developed new, simpler sample preparation techniques including one to handle tissue culture media. 3. Improved on the
Urine analysis concerning xenon for doping control purposes.
Thevis, Mario; Piper, Thomas; Geyer, Hans; Schaefer, Maximilian S; Schneemann, Julia; Kienbaum, Peter; Schänzer, Wilhelm
2015-01-15
On September 1(st) 2014, a modified Prohibited List as established by the World Anti-Doping Agency (WADA) became effective featuring xenon as a banned substance categorized as hypoxia-inducible factor (HIF) activator. Consequently, the analysis of xenon from commonly provided doping control specimens such as blood and urine is desirable, and first data on the determination of xenon from urine in the context of human sports drug testing, are presented. In accordance to earlier studies utilizing plasma as doping control matrix, urine was enriched to saturation with xenon, sequentially diluted, and the target analyte was detected as supported by the internal standard d6 -cyclohexanone by means of gas chromatography/triple quadrupole mass spectrometry (GC/MS/MS) using headspace injection. Three major xenon isotopes at m/z 128.9, 130.9 and 131.9 were targeted in (pseudo) selected reaction monitoring mode enabling the unambiguous identification of the prohibited substance. Assay characteristics including limit of detection (LOD), intraday/interday precision, and specificity as well as analyte recovery under different storage conditions were determined. Proof-of-concept data were generated by applying the established method to urine samples collected from five patients before, during and after (up to 48 h) xenon-based general anesthesia. Xenon was traceable in enriched human urine samples down to the detection limit of approximately 0.5 nmol/mL. The intraday and interday imprecision values of the method were found below 25%, and specificity was demonstrated by analyzing 20 different blank urine samples that corroborated the fitness-for-purpose of the analytical approach to unequivocally detect xenon at non-physiological concentrations in human urine. The patients' urine specimens returned 'xenon-positive' test results up to 40 h post-anesthesia, indicating the limits of the expected doping control detection window. Since xenon has been considered a prohibited substance according to WADA regulations in September 2014, its analysis from common specimens of routine sports drug testing is desirable. In previous studies, its traceability in whole blood and plasma was shown, and herein a complementary approach utilizing doping control urine samples for the GC/MS/MS analysis of xenon was reported. Copyright © 2014 John Wiley & Sons, Ltd.
Abdollahi, Alireza; Hakimi, Faezeh; Doomanlou, Mahsa; Azadegan, Azadeh
2016-04-01
Preventing and starting early treatment of infections in patients whose immunity system is weak due to malignancies like leukemia can reduce mortality. This study aimed to determine microbial and antibiotic resistance patterns in clinical samples of patients with acute leukemia to start early treatment before the results of clinical tests are known. In this cross-sectional study, the clinical samples of all patients hospitalized with the diagnosis of acute leukemia were cultured and their antibiogram was evaluated. Then, the data were analyzed by SPSS 18 based on the objectives of the study. Of a total of 2,366 samples, 18.95% were reported to be positive blood samples, 22.96% were reported to be urine samples and 36% wound samples. E. coli was the most common bacteria isolated from the blood and urine cultures (34% in blood, 32% in urine culture) while Staphylococcus Aureus was the most common in the wound culture (35%). The highest level of sensitivity in the organisms with positive blood culture was to Ciprofloxacin, while in positive urine and wound culture was to Imipenem. The highest resistance in blood, urine and wound culture was to Cotrimoxazole. According to results obtained from this study, it is necessary to conduct appropriate studies on this issue in specific conditions in our country. The findings of this study can be used in clinics for more accurate diagnosis, more effective treatment before the results of clinical tests are known and also for prevention of infection in cancer patients.
Aerosol dilution as a simple strategy for analysis of complex samples by ICP-MS.
Barros, Ariane I; Pinheiro, Fernanda C; Amaral, Clarice D B; Lorençatto, Rodolfo; Nóbrega, Joaquim A
2018-02-01
This study investigated the capability of High Matrix Introduction (HMI) strategy for analysis of dialysis solution and urine samples using inductively coupled plasma mass spectrometry. The use of HMI enables the direct introduction of urine samples and dialysis solutions 2-fold diluted with 0.14molL -1 HNO 3 . Bismuth, Ge, Ir, Li, Pt, Rh, Sc and Tl were evaluated as internal standards for Al, Ag, As, Be, Cd, Cr, Pb, Sb, Se, Tl, and Hg determination in dialysis solution and As, Cd, Hg and Pb determination in urine samples. Helium collision cell mode (4.5mLmin -1 ) was efficient to overcome polyatomic interferences in As, Se and Cr determinations. Mercury memory effects were evaluated by washing with 0.12molL -1 HCl or an alkaline diluent solution prepared with n-butanol, NH 4 OH, EDTA, and Triton X-100. This later solution was efficient for avoiding Hg memory effects in 6h of analysis. Linear calibration curves were obtained for all analytes and detection limits were lower than maximum amounts allowed by Brazilian legislations. Recoveries for all analytes in dialysis solutions and urine samples ranged from 82% to 125% and relative standard deviations for all elements and samples were lower than 7%. Analysis of control internal urine samples was in agreement with certified values at 95% confidence level (t-test; p < 0.05). Copyright © 2017 Elsevier B.V. All rights reserved.
Comparison of population iodine estimates from 24-hour urine and timed-spot urine samples.
Perrine, Cria G; Cogswell, Mary E; Swanson, Christine A; Sullivan, Kevin M; Chen, Te-Ching; Carriquiry, Alicia L; Dodd, Kevin W; Caldwell, Kathleen L; Wang, Chia-Yih
2014-04-01
Median urine iodine concentration (UIC; μg/L) in spot urine samples is recommended for monitoring population iodine status. Other common measures are iodine:creatinine ratio (I/Cr; μg/g) and estimated 24-hour urine iodine excretion (UIE; I/Cr × predicted 24-hour Cr; μg/day). Despite different units, these measures are often used interchangeably, and it is unclear how they compare with the reference standard 24-hour UIE. Volunteers aged 18-39 years collected all their urine samples for 24 hours (n=400). Voids from morning, afternoon, evening, overnight, and a composite 24-hour sample were analyzed for iodine. We calculated median observed 24-hour UIE and 24-hour UIC, and spot UIC, I/Cr, and two measures of estimated UIE calculated using predicted 24-hour Cr from published estimates by Kesteloot and Joosens (varies by age and sex) and published equations by Mage et al. (varies by age, sex, race, and anthropometric measures). We examined mean differences and relative difference across iodine excretion levels using Bland-Altman plots. Median 24-hour UIE was 173.6 μg/day and 24-hour UIC was 144.8 μg/L. From timed-spot urine samples, estimates were: UIC 147.3-156.2 μg/L; I/Cr 103.6-114.3 μg/g, estimated 24-hour UIE (Kesteloot and Joosens) 145.7-163.3 μg/day; and estimated 24-hour UIE (Mage) 176.5-187.7 μg/day. Iodine measures did not vary consistently by timing of spot urine collection. Compared with observed 24-hour UIE, on average, estimated (Mage) 24-hour UIE was not significantly different, while estimated 24-hour UIE (Kesteloot and Joosens) was significantly different for some ethnicity/sex groups. Compared with 24-hour UIC, on average, spot UIC did not differ. Estimates of UIC, I/Cr, and estimated 24-hour UIE (I/Cr × predicted 24-hour Cr) from spot urine samples should not be used interchangeably. Estimated 24-hour UIE, where predicted 24-hour Cr varies by age, sex, ethnicity, and anthropometric measures and was calculated with prediction equations using data from the sample, was more comparable to observed 24-hour UIE than when predicted 24-hour Cr was from published estimates from a different population. However, currently no cutoffs exist to interpret population estimated 24-hour UIE values.
Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina
2015-01-01
Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of 99% (95% CI 0.94-0.99). Taking into account that urine samples may be less sensitive than cervical samples, eight chlamydia studies that compared urine self-collected verses clinician-collected cervical samples had a sensitivity of 87% (95% CI 81-91) and high specificity of 99% (95% CI 0.98-1.00). For gonorrhea testing, self-collected urine samples compared to clinician-collected urethra samples in males produced a sensitivity of 92% (95% CI 83-97) and specificity of 99% (95% CI 0.98-1.00). Conclusion The sensitivity and specificity of vaginal self-collected swabs compared to swabs collected by clinicians supports the use of vaginal swab as the recommended specimen of choice in home-based screening for chlamydia and gonorrhea. Urine samples for gonorrhea collected by men had comparably high sensitivity and specificity, so could be recommended as they can be left at room temperature for several days, allowing for the possibility of mail-in home-based testing. In populations that may not go for testing at all, do not have the option of clinical testing, or who refuse a clinical examination, self-collected screening would be a good alternative. We recommend that guidelines on how to self-collect gonorrhea and chlamydia urine, vaginal, rectal and pharyngeal specimens be published. PMID:26168051
Yu, B; Niki, Y; Armstrong, D
1990-01-01
Immunoblotting was used to detect Aspergillus fumigatus antigen in sera and urines of immunosuppressed rats experimentally infected with A. fumigatus. Organisms were administered by both intravenous and intratracheal injections. Intravenously infected rats developed disseminated aspergillosis, but intratracheally infected rats developed pulmonary disease only. Fungal cultures of blood and urine samples from infected rats were negative. In the urines of intravenously infected rats, antigen was detected 24 to 48 h after infection; in the urines of intratracheally infected animals, antigen was detected on days 4 to 5 after infection. Antigen in serum was detected later than antigen in urine was. Following sodium dodecyl sulfate-polyacrylamide gel electrophoresis and immunoblotting of serum and urine samples, the most strongly reacting antigenic materials were found in the 88-, 40-, 27-, and 20-kilodalton regions. These dominant antigens appeared to be the same as those of control antigens prepared from A. fumigatus grown in vitro. Rabbit antiserum to Aspergillus filtrate antigen was found to be more immunoreactive than antiserum to mycelial or conidial antigen. No mycelium-specific antigens were detected. Images PMID:2199519
Aresta, Antonella; Monaci, Linda; Zambonin, Carlo Giorgio
2002-06-01
An SPME-HPLC-UV method for the determination of delorazepam, a representative benzodiazepine, in spiked human urine samples was developed for the first time. The performances of two commercially available fibers, a carbowax/templated resin (Carbowax/TPR-100) and a polydimethylsiloxane/divinylbenzene (PDMS/DVB), were compared, indicating the latter as the most suitable for urine samples analysis. All the aspects influencing adsorption (extraction time, pH, temperature, salt addition) and desorption (desorption and injection time, desorption solvent mixture composition) of the analyte on the fiber have been investigated. In particular, short extraction times were necessary to reach the equilibrium and very short desorption times were employed. The procedure required simple sample pre-treatment and was able to detect 5 ng/ml in spiked urine, regardless of the complexity of the matrix.
Development of an Inline Urine Monitoring System for the International Space Station
NASA Technical Reports Server (NTRS)
Broyan, James Lee, Jr.; Cibuzar, Banelle R.
2008-01-01
Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.
Rivera-Vélez, Sol-Maiam; Villarino, Nicolas F
2018-02-01
Objectives This aim of this study was to characterize the composition and content of the feline urine metabolome. Methods Eight healthy domestic cats were acclimated at least 10 days before starting the study. Urine samples (~2 ml) were collected by ultrasound-guided cystocentesis. Samples were centrifuged at 1000 × g for 8 mins, and the supernatant was analyzed by gas chromatography/time-of-flight mass spectrometery. The urine metabolome was characterized using an untargeted metabolomics approach. Results Three hundred and eighteen metabolites were detected in the urine of the eight cats. These molecules are key components of at least 100 metabolic pathways. Feline urine appears to be dominated by carbohydrates, carbohydrate conjugates, organic acid and derivatives, and amino acids and analogs. The five most abundant molecules were phenaceturic acid, hippuric acid, pseudouridine phosphate and 3-(4-hydroxyphenyl) propionic acid. Conclusions and relevance This study is the first to characterize the feline urine metabolome. The results of this study revealed the presence of multiple low-molecular-weight substances that were not known to be present in feline urine. As expected, the origin of the metabolites detected in urine was diverse, including endogenous compounds and molecules biosynthesized by microbes. Also, the diet seemed to have had a relevant role on the urine metabolome. Further exploration of the urine metabolic phenotype will open a window for discovering unknown, or poorly understood, metabolic pathways. In turn, this will advance our understanding of feline biology and lead to new insights in feline physiology, nutrition and medicine.
The method for extracting and preparing urine samples for analysis of hydroxy-polycyclic aromatic hydrocarbons, pentachlorophenol and 2,4-D is summarized in this SOP. It covers the extraction, concentration and methylation of samples that are to be analyzed by gas chromatography/...
The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected for the NHEXAS Arizona project. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed ...
Urine human papillomavirus prevalence in women with high-grade cervical lesions.
Nicolau, P; Mancebo, G; Agramunt, S; Solé-Sedeño, J M; Bellosillo, B; Muset, M M; Lloveras, B; Alameda, F; Carreras, R
2014-12-01
To determine the prevalence of human papillomavirus (HPV) in urine samples from women with high-grade cervical lesions. Secondary objectives are to identify the influence of socio-demographic factors and the different genotypes with urinary HPV positivity. 75 women with a positive biopsy for CIN2+ were included in the study from October 2010 to July 2011. A sample of urine was collected immediately before conization at the outpatient clinic. We analyzed the presence of HPV using a PCR technique. The mean age of the patients was 34.8 years (range 24 to 61). All patients had histological CIN2+, of whom 54.67% had CIN3. The prevalence of HPV in urine test was 58.82% in CIN2 population versus 78.05% in CIN3 patients (p 0.072). 31 different genotypes were found. The most frequent HPV genotype was 16-HPV, which was identified in 58% of women with positive HPV-DNA in urine samples. No demographic characteristics were significantly associated to urinary HPV prevalence. Most of the patients with CIN2+ showed positive results for urine HPV test. The prevalence of positive urinary HPV test was higher for patients with CIN3. HPV urine detection could be considered as an acceptable option for high-risk population who skip regular screening programs. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Rossini, Giada; Gaibani, Paolo; Vocale, Caterina; Cagarelli, Roberto; Landini, Maria Paola
2017-09-01
The capability to detect ZIKV RNA is of crucial importance for cases confirmation. However, due to the short-lived viremia, the detection of ZIKV RNA in plasma/serum is challenging for samples collected more than one week after onset of clinical illness. We compared the window time and detection rate of ZIKV RNA in different specimen types (plasma, whole blood and urine) collected simultaneously at several times post-symptom onset. We examined the presence of ZIKV RNA in matched specimens of whole blood, plasma and urine collected in the same date (3-28 days after symptom onset) from 10 ZIKV infected patients. ZIKV RNA was found in plasma as late as 10 days after symptoms onset and tested positive in all 5 (100%) and in 2 of 6 (33,3%) plasma samples collected 1-5 and 6-10 days after symptoms onset, respectively. ZIKV RNA was positive in urine through the 21st day after symptom onset; the detection rate of ZIKV RNA in urine samples was 100% (11/11) for samples collected 1-10 days from symptoms onset, decreasing at later times of sampling. The detection rate of ZIKV RNA in whole blood was comparable to that in urine samples but extended the window of detection of ZIKV RNA up to 26 days after symptom onset. Our results highlight the usefulness of simultaneously testing multiple specimen types in order to extend the rate and the time frame of ZIKV RNA detection, increasing the possibility of cases confirmation through direct diagnosis in convalescence-phase of infection, supplementing serological data which are often difficult to interpret. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen
2016-07-01
Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.
Remane, Daniela; Grunwald, Soeren; Hoeke, Henrike; Mueller, Andrea; Roeder, Stefan; von Bergen, Martin; Wissenbach, Dirk K
2015-08-15
During the last decades exposure sciences and epidemiological studies attracts more attention to unravel the mechanisms for the development of chronic diseases. According to this an existing HPLC-DAD method for determination of creatinine in urine samples was expended for seven analytes and validated. Creatinine, uric acid, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid, and 2-methylhippuric acid were separated by gradient elution (formate buffer/methanol) using an Eclipse Plus C18 Rapid Resolution column (4.6mm×100mm). No interfering signals were detected in mobile phase. After injection of blank urine samples signals for the endogenous compounds but no interferences were detected. All analytes were linear in the selected calibration range and a non weighted calibration model was chosen. Bias, intra-day and inter-day precision for all analytes were below 20% for quality control (QC) low and below 10% for QC medium and high. The limits of quantification in mobile phase were in line with reported reference values but had to be adjusted in urine for homovanillic acid (45mg/L), niacinamide 58.5(mg/L), and indole-3-acetic acid (63mg/L). Comparison of creatinine data obtained by the existing method with those of the developed method showing differences from -120mg/L to +110mg/L with a mean of differences of 29.0mg/L for 50 authentic urine samples. Analyzing 50 authentic urine samples, uric acid, creatinine, hippuric acid, and 2-methylhippuric acid were detected in (nearly) all samples. However, homovanillic acid was detected in 40%, niacinamide in 4% and indole-3-acetic acid was never detected within the selected samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Elimination of 7-aminoclonazepam in urine after a single dose of clonazepam.
Negrusz, Adam; Bowen, Andrew M; Moore, Christine M; Dowd, Sheila M; Strong, Mary Jane; Janicak, Philip G
2003-08-01
The objective of this paper was to determine how long after administration of benzodiazepine clonazepam (CLO), its major metabolite 7-aminoclonazepam (7-ACLO) could be detected in urine collected from 10 healthy volunteers who received a single 3-mg dose of Klonopin (clonazepam). Such data would be of great importance to law enforcement agencies trying to determine the best time interval for urine collection from a victim of drug-facilitated sexual assault in order to reveal drug use. A highly sensitive NCI-GC-MS method for the simultaneous quantitation of CLO and its major metabolite 7-ACLO in urine was developed and validated. The following urine samples were collected from each volunteer: one before CLO administration, and 6 h, and 1, 3, 5, 8, 10, 14, 21 and 28 days after. All urine samples (1 mL) were extracted following addition of the internal standard (D(5)-diazepam) and enzymatic hydrolysis ( beta-glucuronidase) using solid-phase extraction columns. Standard curves for CLO (500-4000 pg x mL(-1)) and 7-ACLO (50-2000 pg x mL(-1)) were prepared by spiking aliquots of negative urine. The urine from every subject was still positive for 7-ACLO 14 days after administration of the drug. Eight of the ten volunteers had measurable amounts of the metabolite 21 days after administration. One volunteer was still positive 28 days after administration. Six of the volunteers had urine concentrations of 7-ACLO that peaked at 1 day after administration. One volunteer had the highest concentration of 7-ACLO at 3 days, two volunteers at 5 days, and one at 8 days. The range of concentrations detected was from 73.0 pg x mL(-1) to 183.2 ng x mL(-1). CLO was not detected in any of the samples.
International Space Station Urine Monitoring System Functional Integration and Science Testing
NASA Technical Reports Server (NTRS)
Rodriguez, Branelle R.; Broyan, James Lee, Jr.
2008-01-01
Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.
International Space Station Urine Monitoring System Functional Integration and Science Testing
NASA Technical Reports Server (NTRS)
Cibuzar, Branelle R.; Broyan, James Lee, Jr.
2009-01-01
Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.
RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, S.; Culligan, B.
2008-08-27
The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared tomore » NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.« less
Joyce, Richard; Kuziene, Viktorija; Zou, Xin; Wang, Xueting; Pullen, Frank; Loo, Ruey Leng
2016-01-01
An ultra-performance liquid chromatography quadrupole time of flight mass spectrometry (UPLC-qTOF-MS) method using hydrophilic interaction liquid chromatography was developed and validated for simultaneous quantification of 18 free amino acids in urine with a total acquisition time including the column re-equilibration of less than 18 min per sample. This method involves simple sample preparation steps which consisted of 15 times dilution with acetonitrile to give a final composition of 25 % aqueous and 75 % acetonitrile without the need of any derivatization. The dynamic range for our calibration curve is approximately two orders of magnitude (120-fold from the lowest calibration curve point) with good linearity (r (2) ≥ 0.995 for all amino acids). Good separation of all amino acids as well as good intra- and inter-day accuracy (<15 %) and precision (<15 %) were observed using three quality control samples at a concentration of low, medium and high range of the calibration curve. The limits of detection (LOD) and lower limit of quantification of our method were ranging from approximately 1-300 nM and 0.01-0.5 µM, respectively. The stability of amino acids in the prepared urine samples was found to be stable for 72 h at 4 °C, after one freeze thaw cycle and for up to 4 weeks at -80 °C. We have applied this method to quantify the content of 18 free amino acids in 646 urine samples from a dietary intervention study. We were able to quantify all 18 free amino acids in these urine samples, if they were present at a level above the LOD. We found our method to be reproducible (accuracy and precision were typically <10 % for QCL, QCM and QCH) and the relatively high sample throughput nature of this method potentially makes it a suitable alternative for the analysis of urine samples in clinical setting.
Molinaro, Ross J; Ritchie, James C
2010-01-01
The following chapter describes a method to measure iothalamate in plasma and urine samples using high performance liquid chromatography combined with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Methanol and water are spiked with the internal standard (IS) iohexol. Iothalamate is isolated from plasma after IS spiked methanol extraction and from urine by IS spiked water addition and quick-spin filtration. The plasma extractions are dried under a stream of nitrogen. The residue is reconstituted in ammonium acetate-formic acid-water. The reconstituted plasma and filtered urine are injected into the HPLC-ESI-MS/MS. Iothalamate and iohexol show similar retention times in plasma and urine. Quantification of iothalamate in the samples is made by multiple reaction monitoring using the hydrogen adduct mass transitions, from a five-point calibration curve.
Guérin, Nicolas; Dai, Xiongxin
2014-06-17
Polonium-210 ((210)Po) can be rapidly determined in drinking water and urine samples by alpha spectrometry using copper sulfide (CuS) microprecipitation. For drinking water, Po in 10 mL samples was directly coprecipitated onto the filter for alpha counting without any purification. For urine, 10 mL of sample was heated, oxidized with KBrO3 for a short time (∼5 min), and subsequently centrifuged to remove the suspended organic matter. The CuS microprecipitation was then applied to the supernatant. Large batches of samples can be prepared using this technique with high recoveries (∼85%). The figures of merit of the methods were determined, and the developed methods fulfill the requirements for emergency and routine radioassays. The efficiency and reliability of the procedures were confirmed using spiked samples.
Nielen, Michel W F; Lasaroms, Johan J P; Essers, Martien L; Sanders, Marieke B; Heskamp, Henri H; Bovee, Toine F H; van Rhijn, J Hans; Groot, Maria J
2007-03-14
A lifetime controlled reference experiment has been performed using 42 veal calves, 21 males and 21 females which were fed and housed according to European regulations and common veterinary practice. During the experiment feed, water, urine and hair were sampled and feed intake and growth were monitored. Thus for the first time residue analysis data were obtained from guaranteed lifetime-untreated animals. The analysis was focused on the natural hormones estradiol and testosterone and their metabolites, on 17beta- and 17alpha-nortestosterone, on 17beta- and 17alpha-boldenone and androsta-1,4-diene-3,17-dione (ADD), and carried out by gas chromatography tandem mass spectrometry (GC/MS/MS), an estrogen bioassay and liquid chromatography (LC) MS/MS. Feed, water and hair samples were negative for the residues tested. Female calf urines showed occasionally low levels of 17alpha-estradiol and 17alpha-testosterone. On one particular sampling day male veal calf urines showed very high levels of 17alpha-testosterone (up to 1000 ng mL(-1)), accompanied by lower levels of estrone and 17beta-testosterone. Despite these extreme levels of natural testosterone, 17beta-boldenone was never detected in the same urine samples; even 17alpha-boldenone and ADD were only occasionally beyond CCalpha (maximum levels 2.7 ng mL(-1)). The data from this unique experiment provide a set of reference values for steroid hormones in calf urine and demonstrate that 17beta-boldenone is not a naturally occurring compound in urine samples.
COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING COTTON GAUZE FOR PESTICIDE STUDIES
To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to t...
COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING GAUZE FOR PESTICIDE STUDIES
To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to te...
Rapid and visual detection of Leptospira in urine by LigB-LAMP assay with pre-addition of dye.
Ali, Syed Atif; Kaur, Gurpreet; Boby, Nongthombam; Sabarinath, T; Solanki, Khushal; Pal, Dheeraj; Chaudhuri, Pallab
2017-12-01
Leptospirosis is considered to be the most widespread zoonotic disease caused by pathogenic species of Leptospira. The present study reports a novel set of primers targeting LigB gene for visual detection of pathogenic Leptospira in urine samples through Loop-mediated isothermal amplification (LAMP). The results were recorded by using Hydroxyl napthol blue (HNB), SYBR GREEN I and calcein. Analytical sensitivity of LAMP was as few as 10 leptospiral organisms in spiked urine samples from cattle and dog. LigB gene based LAMP, termed as LigB-LAMP, was found 10 times more sensitive than conventional PCR. The diagnostic specificity of LAMP was 100% when compared to SYBR green qPCR for detection of Leptospira in urine samples. Though qPCR was found more sensitive, the rapidity and simplicity in setting LAMP test followed by visual detection of Leptospira infection in clinical samples makes LigB-LAMP an alternative and favourable diagnostic tool in resource poor setting. Copyright © 2017 Elsevier Ltd. All rights reserved.
[Cortisol/creatinine ratio in urine (UCC) of healthy cats].
Zimmer, C; Reusch, C E
2003-07-01
In 31 healthy cats urine samples were taken to determine the cortisol/creatinine ratio (UCC) during hospitalisation and at home. The UCC of the samples, which had been taken in the clinic, was significantly higher (0-19 x 10(-6), Median 3 x 10(-6)) than the one of the samples taken at home (0-4 x 10(-6), Median 1 x 10(-6)). The parameter was neither influenced by the cat's age, sex or the fact that the cat stayed inside or outside, nor by the degree of visible agitation. Assay validation achieved good results regarding precision and accuracy of the measuring of cortisol and creatinine in the urine. The study shows that stress--caused by the visit to the veterinarian--can provoke a significant increase of UCC. Therefore, the parameter should be determined only from urine samples taken at home. Furthermore, it is important to notice that cortisol metabolites are measured in varying degree with the different assays. Therefore, it is inevitable that each laboratory generates its own reference values.
Holden, Brad; Guice, Erica A
2014-05-01
In clinical and forensic toxicology laboratories, one commonly used method for urine specimen validity testing is creatinine concentration. In this study, workplace guidelines are examined to determine their relevance to forensic and clinical toxicology samples. Specifically, it investigates the occurrence of urine creatinine concentrations under 20 mg/dL and notes potential issues with factors influencing creatinine concentration by utilizing a simple, novel method consisting of cation-paring high-pressure liquid chromatography in tandem with ultraviolet detection to determine the creatinine concentration in 3019 donors. Of the 4227 sample population in this study, 209 (4.94%) were below the cutoff value of 20 mg/dL for dilute urine. Because there are many factors that can influence the urinary creatinine concentration, samples that have creatinine under the 20 mg/dL cutoff do not always implicate sample adulteration. © 2014 American Academy of Forensic Sciences.
[Detection of West Nile virus in human samples: follow-up studies during the 2015 seasonal period].
Nagy, Anna; Nagy, Orsolya; Bán, Enikő; Molnár, Eszter; Müller, Zsófia; Orbán, Márton; Kecskés, Borbála; Harsányi, Emese Henriett; Kővágó, Levente; Jobbágy, Lajos; Németh, Zoltán; Várnai, Zsuzsanna; Takács, Mária
2017-05-01
West Nile virus, a mosquito-borne viral zoonosis is responsible for human infections in Hungary. Laboratory diagnosis is based on serological tests, however the application of molecular methods has been appreciated. The aim of the study was to investigate blood, cerebrospinal-fluid and urine samples of acutely ill patients and to follow-up PCR positive cases to ascertain the length of virus excretion. Clinical specimens were examined by indirect-immunofluorescent, haemagglutination-inhibition, two PCR tests and Sanger-sequencing. Virus isolation in case of two patients was successful. A follow-up study could be carried out in case of 5 patients. Viral nucleic acid was detectable in urine even for several weeks after symptom onset and viral RNA was present at higher concentration compared with other samples. PCR analysis of urine could provide useful epidemiological and diagnostic information. Therefore, it is recommended to collect urine samples in order to supplement the serological diagnosis. Orv Hetil. 2017; 158(20): 791-796.
Hamond, C; Pestana, C P; Medeiros, M A; Lilenbaum, W
2016-01-01
The aim of this study was to identify Leptospira in urine samples of cattle by direct sequencing of the secY gene. The validity of this approach was assessed using ten Leptospira strains obtained from cattle in Brazil and 77 DNA samples previously extracted from cattle urine, that were positive by PCR for the genus-specific lipL32 gene of Leptospira. Direct sequencing identified 24 (31·1%) interpretable secY sequences and these were identical to those obtained from direct DNA sequencing of the urine samples from which they were recovered. Phylogenetic analyses identified four species: L. interrogans, L. borgpetersenii, L. noguchii, and L. santarosai with the most prevalent genotypes being associated with L. borgpetersenii. While direct sequencing cannot, as yet, replace culturing of leptospires, it is a valid additional tool for epidemiological studies. An unexpected finding from this study was the genetic diversity of Leptospira infecting Brazilian cattle.
Unceta, Nora; Gómez-Caballero, Alberto; García, Deiene; Díaz, Goretti; Guerreiro, Antonio; Piletsky, Sergey; Goicolea, M Aránzazu; Barrio, Ramón J
2013-11-15
This paper reports the application of a chiral imprinted polymer (CIP)-coated stir bar for the selective extraction of (+)-(S)-citalopram (SCIT) and its main metabolites, (+)-(S)-desmethylcitalopram (SDCIT) and (+)-(S)-didesmethylcitalopram (SDDCIT), from urine samples. The developed device has been demonstrated to be capable of selectively extracting the three target analytes from urine samples without saturating the imprinted sites. A CIP-coated stir bar sorptive extraction procedure (CIP-SBSE) is proposed for the isolation of SCIT, SDCIT and SDDCIT followed by their subsequent analysis using liquid chromatography ion trap mass spectrometry (LC-ITMS). Deuterated SCIT-d6 was used as an internal standard. The method was validated using a standard procedure, which revealed that a quantification of 5 ng mL(-1) was obtained in urine samples and that the accuracy and precision were within the established values while no matrix effect was observed. Copyright © 2013 Elsevier B.V. All rights reserved.
False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.
Tenore, Peter L
2012-01-01
In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.
Korchazhkina, Olga; Exley, Christopher; Andrew Spencer, Stephen
2003-09-05
A selective and sensitive method based on derivatisation with 2,4-dinitrophenylhydrazine (DNPH) and consecutive HPLC gradient separation is described for the determination of malondialdehyde (MDA) in urine. Preparation of urine samples involved a one-step derivatisation/extraction procedure. Separation was achieved using a Waters SymmetryC(18) column (3.9 x 150 mm) and linear gradient of acetonitrile in water (from 30% to 70% in 30 min). The overall detection limit of the method was 56 nM of MDA in urine. The recovery of MDA was 94.3+/-8.6%. MDA in urine of healthy volunteers, measured using the method of standard additions, was 0.019+/-0.012 microM/mmol creatinine. MDA in the same samples measured using the 2-thiobarbituric acid (TBA) assay was 0.181+/-0.063 microM/mmol creatinine. We demonstrate that the commonly used TBA assay in conjunction with HPLC may overestimate the MDA concentration in human urine by almost 10-fold.
Analyte variations in consecutive 24-hour urine collections in children.
Ellison, Jonathan S; Hollingsworth, John M; Langman, Craig B; Asplin, John R; Schwaderer, Andrew L; Yan, Phyllis; Bierlein, Maggie; Barraza, Mark A; Defoor, William R; Figueroa, T Ernesto; Jackson, Elizabeth C; Jayanthi, Venkata R; Johnson, Emilie K; Joseph, David B; Shnorhavorian, Margarett
2017-12-01
The metabolic evaluation of children with nephrolithiasis begins with a 24-h urine collection. For adults, the diagnostic yield increases with consecutive collections; however, little is known regarding the variability of multiple 24-h studies in the pediatric population. We sought to evaluate the variability of consecutive 24-h urine collection in children through a multi-institutional study hypothesizing that compared with a single collection, consecutive 24-h urine collections would reveal a greater degree of clinically useful information in the evaluation of children at risk for nephrolithiasis. Including data from six institutions, we identified children less than 18 years of age considered at risk for recurrent nephrolithiasis, undergoing metabolic evaluation. We evaluated a subset of patients performing two collections with urine creatinine varying by 10% or less during a 7-day period. Discordance between repeat collections based on normative urine chemistry values was evaluated. A total of 733 children met inclusion criteria, and in over a third both urine calcium and urine volume differed by 30% or more between samples. Urine oxalate demonstrated greater variation between collections in children <5 years than among older children (p = 0.030) while variation in other parameters did not differ by age. Discordance between repeat samples based on normative values was most common for urine oxalate (22.5%) and the derived relative supersaturation ratios for both calcium phosphate (25.1%) and calcium oxalate (20.5%). The proportion of discordant samples, based on normative thresholds, as well as variability greater ≥30% and 50%, respectively, are shown in the table. Our analysis indicates that stone risk in as many as one in four children may be misclassified if normative values of only a single 24-h urine are used. In light of these findings, repeat 24-h urine collections prior to targeted intervention to modify stone risk are advised to increase diagnostic yield in children at risk for nephrolithiasis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Reactivation of latent herpes viruses in cosmonauts during a soyuz taxi mission
NASA Astrophysics Data System (ADS)
Mehta, Satish K.; Pierson, Duane L.
2007-09-01
The hypothesis tested by this project is that space flight increases the incidence and duration of herpes virus reactivation and shedding in saliva. Saliva, urine, and blood samples were collected from 3 crew members who participated in a 14-day Odessa Soyuz taxi mission. Saliva samples were collected before, during, and after the mission, and blood and urine were collected before and after the mission. The saliva and urine samples were analyzed using the polymerase chain reaction to detect the presence of 3 important herpes viruses. Epstein-Barr virus (EBV) and varicella-zoster virus (VZV) were tested in saliva, and cytomegalovirus (CMV) was measured in urine samples. Plasma antibodies levels to these viruses were determined by enzyme-linked immunosorbent assay before and after flight. EBV reactivated before, during, and after flight; CMV reactivated before and after flight; and VZV reactivated during and after flight. In other studies, greater frequencies of positive samples and greater numbers of copies of viral DNA have been found. No increases in titer of antibodies to these viruses were found, suggesting that an immune response may not be necessary for reactivation.
Urinary indices in llamas fed different diets.
Lackey, M N; Belknap, E B; Salman, M D; Tinguely, L; Johnson, L W
1995-07-01
Indices of renal function and damage were measured in 12 healthy male adult llamas fed a diet of mixed alfalfa/grass hay (mixed hay) and water ad libitum. Using a collection bag fitted over the preputial area, urine samples were collected at 6, 12, and 24 hours. Serum samples were obtained concurrently to determine endogenous creatinine clearance (CL), total (TE) and fractional excretion (FE) of electrolytes (Na, K, Cl, P), electrolyte CL, urine and serum osmolality, urine enzyme activities (gamma-glutamyltransferase and N-acetyl-beta-D-glucosaminidase), and urine protein concentration. Urine production was quantified. Three months later, 10 of the 12 llamas were fed a grass hay diet and water ad libitum. Similar samples were obtained, and similar measurements were made. Urine production was higher when the llamas were fed the mixed hay diet. Total urine volume for llamas fed mixed hay ranged from 628 to 1,760 ml/24 h, with a median of 1,307.5 ml/24h, compared with a range of 620 to 1,380 ml/24 h and a median of 927.50 ml/24h for llamas fed grass hay. Median urine osmolality was higher in llamas fed mixed hay (1,906 mOsm/kg of body weight, with a range of 1,237 to 2,529 mOsm/kg), compared with llamas fed grass hay (1,666 mOsm/kg with a range of 1,163 to 2,044 mOsm/kg). Creatinine CL did not vary significantly over time for either diet.(ABSTRACT TRUNCATED AT 250 WORDS)
Emwas, Abdul-Hamid; Luchinat, Claudio; Turano, Paola; Tenori, Leonardo; Roy, Raja; Salek, Reza M; Ryan, Danielle; Merzaban, Jasmeen S; Kaddurah-Daouk, Rima; Zeri, Ana Carolina; Nagana Gowda, G A; Raftery, Daniel; Wang, Yulan; Brennan, Lorraine; Wishart, David S
The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.
Pires, Nuno M M; Tao Dong; Berntzen, Lasse; Lonningdal, Torill
2017-07-01
This work focuses on the development of a sophisticated technique via STR typing to unequivocally verify the authenticity of urine samples before sent to laboratories. STR profiling was conducted with the CSF1PO, TPOX, TH01 Multiplex System coupled with a smartphone-based detection method. The promising capability of the method to identify distinct STR profiles from urine of different persons opens the possibility to conduct sample authenticity tests. On-site STR profiling could be realized with a self-contained autonomous device with an integrated PCR microchip shown hereby.
Klein, Sabrina; Nurjadi, Dennis; Horner, Susanne; Heeg, Klaus; Zimmermann, Stefan; Burckhardt, Irene
2018-04-13
While total laboratory automation (TLA) is well established in laboratory medicine, only a few microbiological laboratories are using TLA systems. Especially in terms of speed and accuracy, working with TLA is expected to be superior to conventional microbiology. We compared in total 35,564 microbiological urine cultures with and without incubation and processing with BD Kiestra TLA for a 6-month period each retrospectively. Sixteen thousand three hundred thirty-eight urine samples were analyzed in the pre-TLA period and 19,226 with TLA. Sixty-two percent (n = 10,101/16338) of the cultures processed without TLA and 68% (n = 13,102/19226) of the cultures processed with TLA showed growth. There were significantly more samples with two or more species per sample and with low numbers of colony forming units (CFU) after incubation with TLA. Regarding the type of bacteria, there were comparable amounts of Enterobacteriaceae in the samples, slightly less non-fermenting Gram-negative bacteria, but significantly more Gram-positive cocci, and Gram-positive rods. Especially Alloscardivia omnicolens, Gardnerella vaginalis, Actinomyces spp., and Actinotignum schaalii were significantly more abundant in the samples incubated and processed with TLA. The time to report was significantly lower in the TLA processed samples by 1.5 h. We provide the first report in Europe of a large number of urine samples processed with TLA. TLA showed enhanced growth of non-classical and rarely cultured bacteria from urine samples. Our findings suggest that previously underestimated bacteria may be relevant pathogens for urinary tract infections. Further studies are needed to confirm our findings.
Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan
2013-01-01
Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.
Effect of freeze/thaw cycles on several biomarkers in urine from patients with kidney disease.
Zhang, Yinan; Luo, Yi; Lu, Huijuan; Wang, Niansong; Shen, Yixie; Chen, Ruihua; Fang, Pingyan; Yu, Hong; Wang, Congrong; Jia, Weiping
2015-04-01
Urine samples were collected from eleven randomly selected patients with kidney disease, including diabetic nephropathy, chronic nephritis, and nephritic syndrome. Urine samples were treated with one of four protocols for freezing and thawing: freeze directly and thaw directly; freeze directly and thaw by temperature gradient; freeze by temperature gradient and thaw directly; and freeze by temperature gradient and thaw by temperature gradient. After one to six freeze/thaw cycles at -20°C or -80°C, different biomarkers showed differential stabilities. The concentrations of total protein, calcium, and potassium did not change significantly after five freeze/thaw cycles at either -20°C or -80°C. Albumin could only sustain three freeze/thaw cycles at -20°C before it started to degrade. We recommend that urine be stored at -80°C as albumin and the organic ions could sustain five and six freeze/thaw cycles, respectively, using the simple "direct freeze and direct thaw" protocol. Furthermore, in most cases, gradient freeze/thaw cycles are not necessary for urine sample storage.
Chiesa, Luca Maria; Nobile, Maria; Panseri, Sara; Arioli, Francesco
2017-11-15
The antibiotic overuse in zoothechnics, due to prophylactic and therapeutic treatments, or to their growth-promoting activity, is a major cause for the onset of widespread antibiotic resistance. Of particular relevance to this study, is the antibiotic abuse in pig breeding. Despite the comprehensive literature on residue controls in pig muscle, data on pig urine, a non-invasive, on-farm collectable matrix, are lacking. Therefore, we validated an HPLC-MS/MS method to detect 29 antimicrobials from eight classes and applied it to 43 anonymous pig urine and muscle paired samples and fulfilled the parameters in agreement with the Commission Decision 2002/657/UE. The analytical limits were moreover much lower than the maximum residue limits (MRLs) required by the Commission Regulation 37/2010/UE. In the samples, antibiotics were usually detected at higher frequencies and concentrations in urine than muscle. Urine proved a useful tool to detect antibiotic administration and their excessive use in pig farming is depicted. Copyright © 2017. Published by Elsevier Ltd.
Aladaghlo, Zolfaghar; Fakhari, Alireza; Behbahani, Mohammad
2016-10-01
In this work, an efficient sample preparation method termed solvent-assisted dispersive solid-phase extraction was applied. The used sample preparation method was based on the dispersion of the sorbent (benzophenone) into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was achieved by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre-concentration of the butachlor, the cloudy solution was centrifuged and butachlor in the sediment phase dissolved in ethanol and determined by gas chromatography with flame ionization detection. Under the optimized conditions (solution pH = 7.0, sorbent: benzophenone, 2%, disperser solvent: ethanol, 500 μL, centrifuged at 4000 rpm for 3 min), the method detection limit for butachlor was 2, 3 and 3 μg/L for distilled water, waste water, and urine sample, respectively. Furthermore, the preconcentration factor was 198.8, 175.0, and 174.2 in distilled water, waste water, and urine sample, respectively. Solvent-assisted dispersive solid-phase extraction was successfully used for the trace monitoring of butachlor in urine and waste water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed to ensure consistent data retri...
Jafari, Mostafa; Ebrahimzadeh, Homeira; Banitaba, Mohamma Hossein
2015-11-01
In this work a rapid and simple method for creatinine determination in urine and plasma samples based on aqueous derivatization of creatinine and complete vaporization of sample (as low as 10 µL), followed by ion mobility spectrometry analysis has been proposed. The effect of four important parameters (extraction temperature, total volume of solution, desorption temperature and extraction time) on ion mobility signal has been studied. Under the optimized conditions, the quantitative response of ion mobility spectrometry for creatinine was linear in the range of 0-500 mg L(-1) with a detection limit of 0.6 mg L(-1) in urine and 0-250 mg L(-1) with a detection limit of 2.6 mg L(-1) in plasma sample. The limit of quantitation of creatinine was 2.1 mg L(-1) and 8.7 mg L(-1) in urine and plasma samples, respectively. The relative standard deviation of the method was found to be 13%. The method was successfully applied to the analysis of creatinine in biological samples, showing recoveries from 92% to 104% in urine and 101-110% in plasma samples. Copyright © 2015 Elsevier B.V. All rights reserved.
MELFI Urine Sample First Insertion
2009-04-11
ISS019-E-005715 (11 April 2009) --- Astronaut Michael Barratt, Expedition 19/20 flight engineer, performs an insertion of urine samples into the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) study in the Japanese Kibo laboratory of the International Space Station.
This project consisted of a laboratory study to evaluate an extraction and analysis method for quantifying biomarkers of pesticide exposure and creatinine in urine samples collected with commercially-available disposable diapers. For large exposure studies, such as the National ...
Bomfim, Maria Rosa Quaresma; Koury, Matilde Cota
2006-12-20
We evaluated the use of low-stringency single specific primer PCR (LSSP-PCR) for genetically typing Leptospira directly from urine samples of cattle with clinical suspicion of leptospirosis. Urine samples obtained from 40 cattle with clinical suspicion of leptospirosis were amplified by specific PCR using the following primers: Internal 1/Internal 2 and G1/G2. The internal primers were designed from the gene sequence of the outer membrane lipoprotein Lip32 from Leptospira kirschneri, strain RM52. The PCR products were amplified with these two pairs of primers, which had approximately 497 and 285bp, respectively, and were subsequently used as a template for LSSP-PCR analysis. The genetic signatures from the leptospires which were present in the urine samples allowed us to make a preliminary identification of the leptospires by comparing the LSSP-PCR profiles obtained directly from urine samples with those from reference leptospires. The LSSP-PCR profiles obtained with the Internal 1 primer or with the G1 primer allowed the grouping of the leptospires into serogroups. LSSP-PCR was found to be a useful and sensitive approach capable of identifying leptospires directly from biological samples without the need for prior bacterial isolation. In conclusion, the LSSP-PCR technique may still be helpful in discriminating serogroups of Leptospira from different animal reservoirs, since the early identification of carrier animals and information on the shedding state are crucial to prevent the spread of leptospiral infection to other animals and humans.
Iodine Intakes of Victorian Schoolchildren Measured Using 24-h Urinary Iodine Excretion
Beckford, Kelsey; Margerison, Claire; Skeaff, Sheila A.
2017-01-01
Mandatory fortification of bread with iodized salt was introduced in Australia in 2009, and studies using spot urine collections conducted post fortification indicate that Australian schoolchildren are now replete. However an accurate estimate of daily iodine intake utilizing 24-h urinary iodine excretion (UIE μg/day) has not been reported and compared to the estimated average requirement (EAR). This study aimed to assess daily total iodine intake and status of a sample of primary schoolchildren using 24-h urine samples. Victorian primary school children provided 24-h urine samples between 2011 and 2013, from which urinary iodine concentration (UIC, μg/L) and total iodine excretion (UIE, μg/day) as an estimate of intake was determined. Valid 24-h urine samples were provided by 650 children, mean (SD) age 9.3 (1.8) years (n = 359 boys). The mean UIE of 4–8 and 9–13 year olds was 94 (48) and 111 (57) μg/24-h, respectively, with 29% and 26% having a UIE below the age-specific EAR. The median (IQR) UIC was 124 (83,172) μg/L, with 36% of participants having a UIC < 100 μg/L. This convenience sample of Victorian schoolchildren were found to be iodine replete, based on UIC and estimated iodine intakes derived from 24-h urine collections, confirming the findings of the Australian Health Survey. PMID:28867787
Metabolomic analysis of urine samples by UHPLC-QTOF-MS: Impact of normalization strategies.
Gagnebin, Yoric; Tonoli, David; Lescuyer, Pierre; Ponte, Belen; de Seigneux, Sophie; Martin, Pierre-Yves; Schappler, Julie; Boccard, Julien; Rudaz, Serge
2017-02-22
Among the various biological matrices used in metabolomics, urine is a biofluid of major interest because of its non-invasive collection and its availability in large quantities. However, significant sources of variability in urine metabolomics based on UHPLC-MS are related to the analytical drift and variation of the sample concentration, thus requiring normalization. A sequential normalization strategy was developed to remove these detrimental effects, including: (i) pre-acquisition sample normalization by individual dilution factors to narrow the concentration range and to standardize the analytical conditions, (ii) post-acquisition data normalization by quality control-based robust LOESS signal correction (QC-RLSC) to correct for potential analytical drift, and (iii) post-acquisition data normalization by MS total useful signal (MSTUS) or probabilistic quotient normalization (PQN) to prevent the impact of concentration variability. This generic strategy was performed with urine samples from healthy individuals and was further implemented in the context of a clinical study to detect alterations in urine metabolomic profiles due to kidney failure. In the case of kidney failure, the relation between creatinine/osmolality and the sample concentration is modified, and relying only on these measurements for normalization could be highly detrimental. The sequential normalization strategy was demonstrated to significantly improve patient stratification by decreasing the unwanted variability and thus enhancing data quality. Copyright © 2016 Elsevier B.V. All rights reserved.
Liu, Junguo; Song, Jiuxue; Huang, Karen; Michel, Deborah; Fang, Jim
2018-05-01
A high-performance liquid chromatography tandem-mass spectrometry (HPLC-MS/MS) method has been developed to analyze anthocyanins in urine and plasma to further understand their absorption, distribution, metabolism and excretion. The method employed a Synergi RP-Max column (250 × 4.6 mm, 4 μm) and an API 4000 mass spectrometer. A gradient elution system consisted of mobile phase A (water-1% formic acid) and mobile phase B (acetonitrile) with a flow rate of 0.60 mL/min. The gradient was initiated at 5% B, increased to 21% B at 20 min, and then increased to 40% B at 35 min. The analysis of anthocyanins presents a challenge because of the poor stability of anthocyanins during sample preparation, especially during solvent evaporation. In this method, the degradation of anthocyanins was minimized using protein precipitation and dilute-and-shoot and sample preparation methods for plasma and urine, respectively. No interferences were observed from endogenous compounds. The method has been used to analyze anthocyanin concentrations in urine and plasma samples from volunteers administered saskatoon berries. Cyanidin-3-galactoside, cyanidin-3-glucoside, cyanidin-3-arabinoside, cyanidin-3-xyloside and quercetin-3-galactoside, the five major flavonoid components in saskatoon berries, were identified in plasma and urine samples. Copyright © 2017 John Wiley & Sons, Ltd.
International Space Station Urine Monitoring System Functional Integration and Science Testing
NASA Technical Reports Server (NTRS)
Rodriquez, Branelle R.; Broyan, James Lee, Jr.
2011-01-01
Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.
Genital region cleansing wipes: Effects on urine culture contamination.
Selek, Mehmet Burak; Bektöre, Bayhan; Sezer, Ogün; Kula Atik, Tuğba; Baylan, Orhan; Özyurt, Mustafa
2017-01-30
Urine culture is the gold standard test for revealing the microbial agent causing urinary tract infection (UTI). Culture results are affected by sampling techniques; improper sampling leads to contamination of urine and thus contamination of the culture with urogenital flora. We aimed to evaluate the effect of urogenital cleansing, performed with chlorhexidine-containing genital region cleansing wipes (GRCW) on contamination rates. A total of 2,665 patients with UTI-related complaints and with urine culture requests from various outpatient clinics were enrolled in the study. Of the patients, 1,609 in the experimental group used GRCW before sampling, while 1,046 in the control group did not use any wipes. The contamination rate in the experimental group patients was 7.7%, while it was 15.8% in the control group. Contamination rates were significantly higher in the control group than in the experimental group for both women and men. Contamination rates for children and adults were also significantly lower in the experimental group than in the control group. Our study, conducted in a large population, showed that the use of chlorhexidine-containing cleansing wipes significantly reduced urine culture contamination rates in both genders, in both child and adult age groups. Using GRCW, collection of urine after urogenital area cleansing will decrease the contamination problem.
McLean, Rachael M; Williams, Sheila M; Te Morenga, Lisa A; Mann, Jim I
2018-05-22
We aimed to test the difference between estimates of dietary sodium intake using 24-h diet recall and spot urine collection in a large sample of New Zealand adults. We analysed spot urine results, 24-h diet recall, dietary habits questionnaire and anthropometry from a representative sample of 3312 adults aged 15 years and older who participated in the 2008/09 New Zealand Adult Nutrition Survey. Estimates of adult population sodium intake were derived from 24-h diet recall and spot urine sodium using a formula derived from analysis of INTERSALT data. Correlations, limits of agreement and mean difference were calculated for the total sample, and for population subgroups. Estimated total population 24-h urinary sodium excretion (mean (95% CI)) from spot urine samples was 3035 mg (2990, 3079); 3612 mg (3549, 3674) for men and 2507 mg (2466, 2548) for women. Estimated mean usual daily sodium intake from 24-h diet recall data (excluding salt added at the table) was 2564 mg (2519, 2608); 2849 mg (2779, 2920) for men and 2304 mg (2258, 2350) for women. Correlations between estimates were poor, especially for men, and limits of agreement using Bland-Altman mean difference analysis were wide. There is a poor agreement between estimates of individual sodium intake from spot urine collection and those from 24-hour diet recall. Although, both 24-hour dietary recall and estimated urinary excretion based on spot urine indicate mean population sodium intake is greater than 2 g, significant differences in mean intake by method deserve further investigation in relation to the gold standard, 24-hour urinary sodium excretion.
Peitzsch, Mirko; Pelzel, Daniela; Lattke, Peter; Siegert, Gabriele; Eisenhofer, Graeme
2016-01-01
Measurements of urinary fractionated metadrenalines provide a useful screening test to diagnose phaeochromocytoma. Stability of these compounds and their parent catecholamines during and after urine collection is crucial to ensure accuracy of the measurements. Stabilisation with hydrochloric acid (HCl) can promote deconjugation of sulphate-conjugated metadrenalines, indicating a need for alternative preservatives. Urine samples with an intrinsically acidic or alkaline pH (5.5-6.9 or 7.1-8.7, respectively) were used to assess stability of free catecholamines and their free O-methylated metabolites over 7 days of room temperature storage. Stabilisation with HCl was compared with ethylenediaminetetraacetic acid/metabisulphite and monobasic citric acid. Catecholamines and metabolites were measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Free catecholamines and their O-methylated metabolites were stable in acidic urine samples over 7 days of room temperature storage, independent of the presence or absence of any stabilisation method. In contrast, free catecholamines, but not the free O-methylated metabolites, showed rapid degradation within 24 h and continuing degradation over 7 days in urine samples with an alkaline pH. Adjustment of alkaline urine samples to a pH of 3-5 with HCl or 4.8-5.4 with citric acid completely blocked degradation of catecholamines. Ethylenediaminetetraacetic acid/metabisulphite, although reducing the extent of degradation of catecholamines in alkaline urine, was largely ineffectual as a stabiliser. Citric acid is equally effective as HCl for stabilisation of urinary free catecholamines and minimises hazards associated with use of strong inorganic acids while avoiding deconjugation of sulphate-conjugated metabolites during simultaneous LC-MS/MS measurements of free catecholamines and their free O-methylated metabolites.
Unreliable alcohol testing in a shipping safety programme.
Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn
2009-08-10
Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.
Implementation of bioassay methods to improve assessment of incorporated radionuclides.
Oeh, U; Andrasi, A; Bouvier-Capely, C; De Carlan, L; Fischer, H; Franck, D; Höllriegl, V; Li, W B; Ritt, J; Roth, P; Schmitzer, Ch; Wahl, W; Zombori, P
2007-01-01
The present work which was carried out in the framework of an EU project (IDEA: Internal Dosimetry-Enhancements in Application; Contract Number: FIKR CT2001 00164) shall provide commonly acceptable guidelines for optimum performance of ICP-MS measurements with focus on urinary measurements of uranium, thorium and actinides. From the results of this work it is recommended that, whenever feasible, 24 h urine sampling should be conducted to avoid large uncertainties in the quantitation of daily urinary excretion values. For storage, urine samples should be acidified and kept frozen before analysis. Measurement of total uranium in urine by ICP-MS at physiological levels (<10 ng.l(-1)) requires no sample preparation besides UV photolysis and/or dilution. For the measurement of thorium in urine by ICP-MS, it can be concluded, that salt removal from the urine samples is not recommended. For the measurement of actinides in urine it is shown that ICP-MS is well-suited and a good alternative to alpha-spectrometry for isotopes with T1/2>5x10(4) years. In general, ICP-MS measurements are an easy, fast and cost-saving methodology. New improved measuring techniques (HR-SF-ICP-MS) with detection limits in urine of 150 pg.l(-1) (1.9 microBq.l(-1)) for 238U, 30 pg.l(-1) (2.4 microBq.l(-1)) for 235U and 100 pg.l(-1) (0.4 microBq.l(-1)) for (232)Th, respectively, meet all necessary requirements. This method should therefore become the routine technique for incorporation monitoring of workers and of members of the general public, in particular for uranium contamination.
Su, Guanyong; Letcher, Robert J; Yu, Hongxia
2015-12-24
Organophosphate (OP) diesters in urine samples have potential use as biomarkers of organism exposure to environmentally relevant OP triester precursors and in particular OP triester flame retardants. This present study developed a quantitatively sensitive ultra high pressure liquid chromatography (UHPLC-MS) based method for urine and the determination of OP diesters (i.e. diphenyl phosphate (DPHP), bis(2-chloroethyl) phosphate (BCEP), bis(2-chloroisopropyl) phosphate (BDCIPP), di-n-butyl phosphate (DNBP), di(2-ethylhexyl) phosphate (DEHP), bis(1-chloro-2-propyl) phosphate (BCIPP), and bis(2-butoxyethyl) phosphate (BBOEP)). Fortified with the 7 OP diesters, 1mL of human urine sample was cleaned up using weak anion exchange solid phase extraction and eluted with high ionic strength ammonium acetate buffer. Subsequently, 4 non-chlorinated OP diesters were directly determined using UHPLC-electrospray(-)-triple quadrupole-MS (UHPLC-ESI(-)-QqQ-MS), and UHPLC-ESI(+)-QqQ-MS was used for determination of 3 chlorinated OP diesters after methylation using diazomethane. Recovery efficiencies of OP diesters ranged from 88 to 160% at three spiking levels (0.4, 2 and 10ng/mL urine). Matrix effects (MEs) and method limits of quantification (MLOQs) were 15-134% and 0.10-0.32ng/mL urine, respectively. Concentrations of OP diesters in n=12 urine samples (from 4 Canadian residents, 2014) varied as follows, nd-<0.28 (DNBP), nd-1.29 (DPHP), nd-<0.28 (DEHP), <0.16-12.33 (BCEP), nd-1.17 (BCDIPP) and nd-0.68ng/mL (BCIPP). Copyright © 2015. Published by Elsevier B.V.
Kuwayama, Kenji; Miyaguchi, Hajime; Yamamuro, Tadashi; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki
2016-07-01
In forensic drug testing, it is important to immediately take biological specimens from suspects and victims to prove their drug intake. We evaluated the effectiveness of saliva and fingerprints as alternative specimens to urine and blood in terms of ease of sampling, drug detection sensitivity, and drug detection periods for each specimen type. After four commercially available pharmaceutical products were administered to healthy subjects, each in a single dose, their urine, blood, saliva, and fingerprints were taken at predetermined sampling times over approximately four weeks. Fourteen analytes (the administered drugs and their main metabolites) were extracted from each specimen using simple pretreatments, such as dilution and deproteinization, and were analyzed using liquid chromatography/mass spectrometry (LC/MS). Most of the analytes were detected in saliva and fingerprints, as well as in urine and blood. The time-courses of drug concentrations were similar between urine and fingerprints, and between blood and saliva. Compared to the other compounds, the acidic compounds, for example ibuprofen, acetylsalicylic acid, were more difficult to detect in all specimens. Acetaminophen, dihydrocodeine, and methylephedrine were detected in fingerprints at later sampling times than in urine. However, a relationship between the drug structures and their detection periods in each specimen was not found. Saliva and fingerprints could be easily sampled on site without using special techniques or facilities. In addition, fingerprints could be immediately analyzed after simple and rapid treatment. In cases where it would be difficult to immediately obtain urine and blood, saliva and fingerprints could be effective alternative specimens for drug testing. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Wang, X-H; Zhang, G; Fan, Y-Y; Yang, X; Sui, W-J; Lu, X-X
2013-03-01
Rapid identification of bacterial pathogens from clinical specimens is essential to establish an adequate empirical antibiotic therapy to treat urinary tract infections (UTIs). We used matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) combined with UF-1000i urine flow cytometry of urine specimens to quickly and accurately identify bacteria causing UTIs. We divided each urine sample into three aliquots for conventional identification, UF-1000i, and MALDI-TOF MS, respectively. We compared the results of the conventional method with those of MALDI-TOF MS combined with UF-1000i, and discrepancies were resolved by 16S rRNA gene sequencing. We analyzed 1456 urine samples from patients with UTI symptoms, and 932 (64.0%) were negative using each of the three testing methods. The combined method used UF-1000i to eliminate negative specimens and then MALDI-TOF MS to identify the remaining positive samples. The combined method was consistent with the conventional method in 1373 of 1456 cases (94.3%), and gave the correct result in 1381 of 1456 cases (94.8%). Therefore, the combined method described here can directly provide a rapid, accurate, definitive bacterial identification for the vast majority of urine samples, though the MALDI-TOF MS software analysis capabilities should be improved, with regard to mixed bacterial infection. Copyright © 2012 Elsevier B.V. All rights reserved.
Willis, Carolyn M; Britton, Lezlie E; Harris, Rob; Wallace, Joshua; Guest, Claire M
In a previous canine study, we demonstrated that volatile organic compounds specific to bladder cancer are present in urine headspace, subsequently showing that up to 70% of tumours can be correctly classified using an electronic nose. This study aimed to evaluate the sensitivity and specificity which can be achieved by a group of four trained dogs. In a series of 30 double-blind test runs, each consisting of one bladder cancer urine sample placed alongside six controls, the highest sensitivity achieved by the best performing dog was 73% (95% CI 55-86%), with the group as a whole correctly identifying the cancer samples 64% (95% CI 55-73%) of the time. Specificity of the dogs individually ranged from 92% (95% CI 82-97%) for urine samples obtained from healthy, young volunteers down to 56% (95% CI 42-68%) for those taken from older patients with non-cancerous urological disease. Odds ratio comparisons confirmed a significant decrease in performance as the extent of urine dipstick abnormality and/or pathology amongst the control population increased. Importantly, however, statistical analysis indicated that covariates such as smoking, gender and age, as well as blood, protein and /or leucocytes in the urine did not significantly alter the odds of response to the cancer samples. Our results provide further evidence that volatile biomarkers for bladder cancer exist in urine headspace, and that these have the potential to be exploited for diagnosis.
Prapamontol, Tippawan; Sutan, Kunrunya; Laoyang, Sompong; Hongsibsong, Surat; Lee, Grace; Yano, Yukiko; Hunter, Ronald Elton; Ryan, P Barry; Barr, Dana Boyd; Panuwet, Parinya
2014-01-01
We report two analytical methods for the measurement of dialkylphosphate (DAP) metabolites of organophosphate pesticides in human urine. These methods were independently developed/modified and implemented in two separate laboratories and cross validated. The aim was to develop simple, cost effective, and reliable methods that could use available resources and sample matrices in Thailand and the United States. While several methods already exist, we found that direct application of these methods required modification of sample preparation and chromatographic conditions to render accurate, reliable data. The problems encountered with existing methods were attributable to urinary matrix interferences, and differences in the pH of urine samples and reagents used during the extraction and derivatization processes. Thus, we provide information on key parameters that require attention during method modification and execution that affect the ruggedness of the methods. The methods presented here employ gas chromatography (GC) coupled with either flame photometric detection (FPD) or electron impact ionization-mass spectrometry (EI-MS) with isotopic dilution quantification. The limits of detection were reported from 0.10ng/mL urine to 2.5ng/mL urine (for GC-FPD), while the limits of quantification were reported from 0.25ng/mL urine to 2.5ng/mL urine (for GC-MS), for all six common DAP metabolites (i.e., dimethylphosphate, dimethylthiophosphate, dimethyldithiophosphate, diethylphosphate, diethylthiophosphate, and diethyldithiophosphate). Each method showed a relative recovery range of 94-119% (for GC-FPD) and 92-103% (for GC-MS), and relative standard deviations (RSD) of less than 20%. Cross-validation was performed on the same set of urine samples (n=46) collected from pregnant women residing in the agricultural areas of northern Thailand. The results from split sample analysis from both laboratories agreed well for each metabolite, suggesting that each method can produce comparable data. In addition, results from analyses of specimens from the German External Quality Assessment Scheme (G-EQUAS) suggested that the GC-FPD method produced accurate results that can be reasonably compared to other studies. Copyright © 2013 Elsevier GmbH. All rights reserved.
2D-electrophoresis and the urine proteome map: where do we stand?
Candiano, Giovanni; Santucci, Laura; Petretto, Andrea; Bruschi, Maurizio; Dimuccio, Veronica; Urbani, Andrea; Bagnasco, Serena; Ghiggeri, Gian Marco
2010-03-10
The discovery of urinary biomarkers is a main topic in clinical medicine. The development of proteomics has rapidly changed the knowledge on urine protein composition and probably will modify it again. Two-dimensional electrophoresis (2D-PAGE) coupled with mass spectrometry has represented for years the technique of choice for the analysis of urine proteins and it is time to draw some conclusions. This review will focus on major methodological aspects related to urine sample collection, storage and analysis by 2D-PAGE and attempt to define an advanced normal urine protein map. Overall, 1118 spots were reproducibly found in normal urine samples but only 275 were characterized as isoforms of 82 proteins. One-hundred height spots belonging to 30 proteins were also detected in plasma and corresponded to typical plasma components. The identity of most of the proteins found in normal urine by 2D-PAGE remains to be determined, the majority being low-molecular weight proteins (<30 kDa). Equalization procedures would also enhance sensitivity of the analysis and allow low abundance proteins to be characterized. Therefore, we are still on the way to define the normal urine composition. Technology advancements in concentrating procedure will improve sensitivity and give the possibility to purify proteins for mass spectrometry. Copyright (c) 2009 Elsevier B.V. All rights reserved.
Radioimmunoassay for etorphine in horses with a /sup 125/I analog of etorphine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tai, C.L.; Wang, C.; Weckman, T.J.
1988-05-01
To improve the sensitivity and specificity of screening for etorphine in horses, an /sup 125/I-labeled etorphine analog was synthesized and an antibody to etorphine was raised in rabbits. A radioimmunoassay (RIA) for etorphine was developed, using these reagents. Bound and free /sup 125/I-labeled etorphine was separated by a double-antibody method that reduced interference from materials associated with equine urine. The /sup 125/I-labeled etorphine binding was rarely greater than 250 pg of background etorphine equivalents/ml in raw urine and was 100 pg/ml in hydrolyzed urine. The /sup 125/I-RIA was capable of detecting etorphine equivalents in urine above these background values. Etorphinemore » equivalents were detected in equine urine samples for about 7 days after 4 mares were dosed with 0.22 microgram of etorphine/kg of body weight, IV. The stability of etorphine in urine from these mares was evaluated. Urine from these dosed mares was held in constant -20 C storage, and aliquots were repeatedly frozen and thawed. When analyzed for etorphine equivalents using an /sup 125/I-RIA, etorphine and its metabolites in urine samples were stable for less than or equal to 38 days if continuously frozen and also were resistant to repeated freezing and thawing.« less
Dereziński, Paweł; Klupczyńska, Agnieszka; Sawicki, Wojciech; Kokot, Zenon J
2016-01-01
Creatinine determination in urine is used to estimate the completeness of the 24-h urine collection, compensation for variable diuresis and as a preliminary step in protein profiling in urine. Despite the fact that a wide range of methods of measuring creatinine level in biofluids has been developed, many of them are adversely affected by interfering substances. A new liquid chromatography-tandem mass spectrometry method for creatinine determination in urine has been developed. Chromatographic separation was performed by applying C18 column and a gradient elution. Analyses were carried out on a triple quadrupole mass spectrometer equipped with an electrospray ion source. The developed method was fully validated according to the international guidelines. The quantification range of the method was 5-1500 ng/mL, which corresponds to 1-300 mg/dL in urine. Limit of detection and quantitation were 2 and 5 ng/mL, respectively. Additionally, the comparison of creatinine determination by newly developed method to the colorimetric method was performed. The method enables the determination of creatinine in urine samples with a minimal sample preparation, excellent sensitivity and prominent selectivity. Since mass spectrometry allows to measure a number of compounds simultaneously, a future perspective would be to incorporate the determination of other clinically important compounds excreted in urine.
Biomarkers of Coordinate Metabolic Reprogramming in Colorectal Tumors in Mice and Humans
Manna, Soumen K.; Tanaka, Naoki; Krausz, Kristopher W.; Haznadar, Majda; Xue, Xiang; Matsubara, Tsutomu; Bowman, Elise D.; Fearon, Eric R.; Harris, Curtis C.; Shah, Yatrik M.; Gonzalez, Frank J.
2014-01-01
BACKGROUND & AIMS There are no robust noninvasive methods for colorectal cancer screening and diagnosis. Metabolomic and gene expression analyses of urine and tissue samples from mice and humans were used to identify markers of colorectal carcinogenesis. METHODS Mass spectrometry-based metabolomic analyses of urine and tissues from wild-type C57BL/6J and ApcMin/+ mice, as well as from mice with azoxymethane-induced tumors, was employed in tandem with gene expression analysis. Metabolomics profiles were also determined on colon tumor and adjacent non-tumor tissues from 39 patients. The effects of β-catenin activity on metabolic profiles were assessed in mice with colon-specific disruption of Apc. RESULTS Thirteen markers were found in urine associated with development of colorectal tumors in ApcMin/+ mice. Metabolites related to polyamine metabolism, nucleic acid metabolism, and methylation, identified tumor-bearing mice with 100% accuracy, and also accurately identified mice with polyps. Changes in gene expression in tumor samples from mice reflected the observed changes in metabolic products detected in urine; similar changes were observed in mice with azoxymethane-induced tumors and mice with colon-specific activation of β-catenin. The metabolic alterations indicated by markers in urine therefore appear to occur during early stages of tumorigenesis, when cancer cells are proliferating. In tissues from patients, tumors had stage-dependent increases in 12 metabolites associated with the same metabolic pathways identified in mice (including amino acid metabolism and polyamine metabolism). Ten metabolites that were increased in tumor tissues, compared with non-tumor tissues (proline, threonine, glutamic acid, arginine, N1-acetylspermidine, xanthine, uracil, betaine, symmetric dimethylarginine, and asymmetric-dimethylarginine), were also increased in urine from tumor-bearing mice. CONCLUSIONS Gene expression and metabolomic profiles of urine and tissue samples from mice with colorectal tumors and of colorectal tumor samples from patients revealed metabolites associated with specific metabolic changes that are indicative of early-stage tumor development. These urine and tissue markers might be used in early detection of colorectal cancer. PMID:24440673
Gaudreau, Éric; Bérubé, René; Bienvenu, Jean-François; Fleury, Normand
2016-06-01
Data on the stability of monohydroxy polycyclic aromatic hydrocarbons (OH-PAHs; metabolites of PAHs) in urine are needed in order to effectively study the effects of PAHs in the body, but the relevant data are not available in the literature. Therefore, in this work, we investigated the stability of OH-PAHs in urine. For each OH-PAH studied, the free form (as opposed to the conjugated form) comprised <10 % of the total OH-PAH in urine samples obtained from a normal population, except for 9-OH-phenanthrene (where the free form represented 22.2 % of the total 9-OH-phenanthrene). 1-Naphthol and 9-OH-phenanthrene were found to be less stable in their free forms in urine than in their conjugated forms when the urine samples were stored at 4 °C or room temperature. Free 3-OH-fluoranthene was also very unstable at 4 °C or room temperature. The conjugated forms of the OH-PAHs were more stable than their corresponding free forms. However, the free and conjugated forms of all the OH-PAHs were stable in urine at -20 °C and -80 °C. A freeze and thaw assay also revealed that freezing and thawing had minimal impact on the stability of the OH-PAHs in urine. For the derivatized extracts, storing the samples under an argon atmosphere at 4 °C was found to maintain sample integrity. In order to measure the stabilities of 19 hydroxylated metabolites of PAHs in urine, we developed a method with sensitivity in the low pg/mL range using nine labeled internal standards. This method combined enzymatic deconjugation with liquid-liquid extraction, derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA), and gas chromatography/tandem mass spectrometry (GC-MS/MS). Graphical abstract Stability of the conjugated forms of the OH-PAHs versus free forms (e.g. 1-naphthol).
Lawn, Stephen D; Kerkhoff, Andrew D; Burton, Rosie; Schutz, Charlotte; Boulle, Andrew; Vogt, Monica; Gupta-Wright, Ankur; Nicol, Mark P; Meintjes, Graeme
2017-03-21
We previously reported that one-third of HIV-positive adults requiring medical admission to a South African district hospital had laboratory-confirmed tuberculosis (TB) and that almost two-thirds of cases could be rapidly diagnosed using Xpert MTB/RIF-testing of concentrated urine samples obtained on the first day of admission. Implementation of urine-based, routine, point-of-care TB screening is an attractive intervention that might be facilitated by use of a simple, low-cost diagnostic tool, such as the Determine TB-LAM lateral-flow rapid test for HIV-associated TB. Sputum, urine and blood samples were systematically obtained from unselected HIV-positive adults within 24 hours of admission to a South African township hospital. Additional clinical samples were obtained during hospitalization as clinically indicated. TB was defined by the detection of Mycobacterium tuberculosis in any sample using Xpert MTB/RIF or liquid culture. The diagnostic yield, accuracy and prognostic value of urine-lipoarabinomannan (LAM) testing were determined, but urine-LAM results did not inform treatment decisions. Consecutive HIV-positive adult acute medical admissions not already receiving TB treatment (n = 427) were enrolled regardless of clinical presentation or symptoms. TB was diagnosed in 139 patients (TB prevalence 32.6%; median CD4 count 80 cells/μL). In the first 24 hours of admission, sputum (spot and/or induced) samples were obtained from 37.0% of patients and urine samples from 99.5% of patients (P < 0.001). The diagnostic yields from these specimens were 19.4% (n = 27/139) for sputum-microscopy, 26.6% (n = 37/139) for sputum-Xpert, 38.1% (n = 53/139) for urine-LAM and 52.5% (n = 73/139) for sputum-Xpert/urine-LAM combined (P < 0.01). Corresponding yields among patients with CD4 counts <100 cells/μL were 18.9%, 24.3%, 55.4% and 63.5%, respectively (P < 0.01). The diagnostic yield of urine-LAM was unrelated to respiratory symptoms, and LAM assay specificity (using a grade-2 cut-off) was 98.9% (274/277; 95% confidence interval [CI] 96.9-99.8). Among TB cases, positive urine-LAM status was strongly associated with mortality at 90 days (adjusted hazard ratio 4.20; 95% CI 1.50-11.75). Routine testing for TB in newly admitted HIV-positive adults using Determine TB-LAM to test urine provides major incremental diagnostic yield with very high specificity when used in combination with sputum testing and has important utility among those without respiratory TB symptoms and/or unable to produce sputum. The assay also rapidly identifies individuals with a poor prognosis.
The endothelial lipase protein is promising urinary biomarker for diagnosis of gastric cancer.
Dong, Xueyan; Wang, Guoqing; Zhang, Guoqing; Ni, Zhaohui; Suo, Jian; Cui, Juan; Cui, Ai; Yang, Qing; Xu, Ying; Li, Fan
2013-03-19
Gastric cancer is one of the most common malignant tumors in the world. Finding effective diagnostic biomarkers in urine or serum would represent the most ideal solution to detecting gastric cancer during annual physical examination. This study was to evaluate the potential of endothelial lipase (EL) as a urinary biomarker for diagnosis of gastric cancer. The expression levels of EL was measured using Western blotting and immunohistochemical staining experiments on (tissue, serum, and urine) samples of gastric cancer patients versus healthy people. We also checked the EL levels in the urine samples of other cancer types (lung, colon and rectum cancers) and benign lesions (gastritis and gastric leiomyoma) to check if EL was specific to gastric cancer. We observed a clear separation between the EL expression levels in the urine samples of 90 gastric cancer patients and of 57 healthy volunteers. It was approximately 9.9 fold average decrease of the EL expression levels in the urine samples of gastric cancer compared to the healthy controls (P <0.0001), achieving a 0.967 AUC value for the ROC (receiver operating characteristic) curve, demonstrating it's highly accurate as a diagnostic marker for gastric cancer. Interestingly, the expression levels of EL in tissue and serum samples were not nearly as discriminative as in urine samples (P = 0.90 and P = 0.79). In immunohistochemical experiments, positive expression of the EL protein was found in 67% (8/12) of gastric adjacent noncancerous and in 58% (7/12) of gastric cancer samples. There was no significant statistical in the expression levels of this protein between the gastric cancer and the matching noncancerous tissues (P =0.67). The urinary EL as a highly accurate gastric cancer biomarker that is potentially applicable to the general screening with high sensitivity and specificity. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/4527331618757552.
The endothelial lipase protein is promising urinary biomarker for diagnosis of gastric cancer
2013-01-01
Background Gastric cancer is one of the most common malignant tumors in the world. Finding effective diagnostic biomarkers in urine or serum would represent the most ideal solution to detecting gastric cancer during annual physical examination. This study was to evaluate the potential of endothelial lipase (EL) as a urinary biomarker for diagnosis of gastric cancer. Methods The expression levels of EL was measured using Western blotting and immunohistochemical staining experiments on (tissue, serum, and urine) samples of gastric cancer patients versus healthy people. We also checked the EL levels in the urine samples of other cancer types (lung, colon and rectum cancers) and benign lesions (gastritis and gastric leiomyoma) to check if EL was specific to gastric cancer. Result We observed a clear separation between the EL expression levels in the urine samples of 90 gastric cancer patients and of 57 healthy volunteers. It was approximately 9.9 fold average decrease of the EL expression levels in the urine samples of gastric cancer compared to the healthy controls (P <0.0001), achieving a 0.967 AUC value for the ROC (receiver operating characteristic) curve, demonstrating it’s highly accurate as a diagnostic marker for gastric cancer. Interestingly, the expression levels of EL in tissue and serum samples were not nearly as discriminative as in urine samples (P = 0.90 and P = 0.79). In immunohistochemical experiments, positive expression of the EL protein was found in 67% (8/12) of gastric adjacent noncancerous and in 58% (7/12) of gastric cancer samples. There was no significant statistical in the expression levels of this protein between the gastric cancer and the matching noncancerous tissues (P =0.67). Conclusions The urinary EL as a highly accurate gastric cancer biomarker that is potentially applicable to the general screening with high sensitivity and specificity. Virtual Slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/4527331618757552 PMID:23510199
O’Brien, Kathryn; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C
2013-01-01
Background Urinary tract infection (UTI) in children may be associated with long-term complications that could be prevented by prompt treatment. Aim To determine the prevalence of UTI in acutely ill children ≤ 5 years presenting in general practice and to explore patterns of presenting symptoms and urine sampling strategies. Design and setting Prospective observational study with systematic urine sampling, in general practices in Wales, UK. Method In total, 1003 children were recruited from 13 general practices between March 2008 and July 2010. The prevalence of UTI was determined and multivariable analysis performed to determine the probability of UTI. Result Out of 597 (60.0%) children who provided urine samples within 2 days, the prevalence of UTI was 5.9% (95% confidence interval [CI] = 4.3% to 8.0%) overall, 7.3% in those < 3 years and 3.2% in 3–5 year olds. Neither a history of fever nor the absence of an alternative source of infection was associated with UTI (P = 0.64; P = 0.69, respectively). The probability of UTI in children aged ≥3 years without increased urinary frequency or dysuria was 2%. The probability of UTI was ≥5% in all other groups. Urine sampling based purely on GP suspicion would have missed 80% of UTIs, while a sampling strategy based on current guidelines would have missed 50%. Conclusion Approximately 6% of acutely unwell children presenting to UK general practice met the criteria for a laboratory diagnosis of UTI. This higher than previously recognised prior probability of UTI warrants raised awareness of the condition and suggests clinicians should lower their threshold for urine sampling in young children. The absence of fever or presence of an alternative source of infection, as emphasised in current guidelines, may not rule out UTI in young children with adequate certainty. PMID:23561695
Glyphosate and aminomethylphosphonic acid are not detectable in human milk.
McGuire, Michelle K; McGuire, Mark A; Price, William J; Shafii, Bahman; Carrothers, Janae M; Lackey, Kimberly A; Goldstein, Daniel A; Jensen, Pamela K; Vicini, John L
2016-05-01
Although animal studies have shown that exposure to glyphosate (a commonly used herbicide) does not result in glyphosate bioaccumulation in tissues, to our knowledge there are no published data on whether it is detectable in human milk and therefore consumed by breastfed infants. We sought to determine whether glyphosate and its metabolite aminomethylphosphonic acid (AMPA) could be detected in milk and urine produced by lactating women and, if so, to quantify typical consumption by breastfed infants. We collected milk (n = 41) and urine (n = 40) samples from healthy lactating women living in and around Moscow, Idaho and Pullman, Washington. Milk and urine samples were analyzed for glyphosate and AMPA with the use of highly sensitive liquid chromatography-tandem mass spectrometry methods validated for and optimized to each sample matrix. Our milk assay, which was sensitive down to 1 μg/L for both analytes, detected neither glyphosate nor AMPA in any milk sample. Mean ± SD glyphosate and AMPA concentrations in urine were 0.28 ± 0.38 and 0.30 ± 0.33 μg/L, respectively. Because of the complex nature of milk matrixes, these samples required more dilution before analysis than did urine, thus decreasing the sensitivity of the assay in milk compared with urine. No difference was found in urine glyphosate and AMPA concentrations between subjects consuming organic compared with conventionally grown foods or between women living on or near a farm/ranch and those living in an urban or suburban nonfarming area. Our data provide evidence that glyphosate and AMPA are not detectable in milk produced by women living in this region of the US Pacific Northwest. By extension, our results therefore suggest that dietary glyphosate exposure is not a health concern for breastfed infants. This study was registered at clinicaltrials.gov as NCT02670278. © 2016 American Society for Nutrition.
Peng, Yaguang; Li, Wei; Wang, Yang; Chen, Hui; Bo, Jian; Wang, Xingyu; Liu, Lisheng
2016-01-01
24-h urinary sodium excretion is the gold standard for evaluating dietary sodium intake, but it is often not feasible in large epidemiological studies due to high participant burden and cost. Three methods—Kawasaki, INTERSALT, and Tanaka—have been proposed to estimate 24-h urinary sodium excretion from a spot urine sample, but these methods have not been validated in the general Chinese population. This aim of this study was to assess the validity of three methods for estimating 24-h urinary sodium excretion using spot urine samples against measured 24-h urinary sodium excretion in a Chinese sample population. Data are from a substudy of the Prospective Urban Rural Epidemiology (PURE) study that enrolled 120 participants aged 35 to 70 years and collected their morning fasting urine and 24-h urine specimens. Bias calculations (estimated values minus measured values) and Bland-Altman plots were used to assess the validity of the three estimation methods. 116 participants were included in the final analysis. Mean bias for the Kawasaki method was -740 mg/day (95% CI: -1219, 262 mg/day), and was the lowest among the three methods. Mean bias for the Tanaka method was -2305 mg/day (95% CI: -2735, 1875 mg/day). Mean bias for the INTERSALT method was -2797 mg/day (95% CI: -3245, 2349 mg/day), and was the highest of the three methods. Bland-Altman plots indicated that all three methods underestimated 24-h urinary sodium excretion. The Kawasaki, INTERSALT and Tanaka methods for estimation of 24-h urinary sodium excretion using spot urines all underestimated true 24-h urinary sodium excretion in this sample of Chinese adults. Among the three methods, the Kawasaki method was least biased, but was still relatively inaccurate. A more accurate method is needed to estimate the 24-h urinary sodium excretion from spot urine for assessment of dietary sodium intake in China. PMID:26895296
Parrish, Randall R; Thirlwall, Matthew F; Pickford, Chris; Horstwood, Matthew; Gerdes, Axel; Anderson, James; Coggon, David
2006-02-01
Accidental exposure to depleted or enriched uranium may occur in a variety of circumstances. There is a need to quantify such exposure, with the possibility that the testing may post-date exposure by months or years. Therefore, it is important to develop a very sensitive test to measure precisely the isotopic composition of uranium in urine at low levels of concentration. The results of an interlaboratory comparison using sector field (SF)-inductively coupled plasma-mass spectrometry (ICP-MS) and multiple collector (MC)-ICP-MS for the measurement of uranium concentration and U/U and U/U isotopic ratios of human urine samples are presented. Three urine samples were verified to contain uranium at 1-5 ng L and shown to have natural uranium isotopic composition. Portions of these urine batches were doped with depleted uranium (DU) containing small quantities of U, and the solutions were split into 100 mL and 400 mL aliquots that were subsequently measured blind by three laboratories. All methods investigated were able to measure accurately U/U with precisions of approximately 0.5% to approximately 4%, but only selected MC-ICP-MS methods were capable of consistently analyzing U/U to reasonable precision at the approximately 20 fg L level of U abundance. Isotope dilution using a U tracer demonstrates the ability to measure concentrations to better than +/-4% with the MC-ICP-MS method, though sample heterogeneity in urine samples was shown to be problematic in some cases. MC-ICP-MS outperformed SF-ICP-MS methods, as was expected. The MC-ICP-MS methodology described is capable of measuring to approximately 1% precision the U/U of any sample of human urine over the entire range of uranium abundance down to <1 ng L, and detecting very small amounts of DU contained therein.
A simple high performance liquid chromatography method for determination of rebamipide in rat urine.
Cooper, Dustin L; Harirforoosh, Sam
2014-01-01
Rebamipide is a mucoprotective agent commonly used to prevent nonsteriodal anti-inflammatory drug-induced gastrointenstinal side effects [1]. Human plasma and urine analysis of rebamipide utilizing high performance liquid chromatography (HPLC) have been reported [2]. Recently, we reported on the plasma levels of rebamipide in presense or absence of celecoxib or diclofenac in rats [3] using a modified HPLC method of detection developed by Jeoung et al. [4]. To tailor the method towards use in urinary rebamipide extraction and analysis, the following modifications were made:•To compensate for high concentrations of rebamipide found in urine, a new rebamipide stock solution was prepared with a final concentration of 50,000 ng/mL.•Rat urine calibration standards were obtained within the range of 50-1000 ng/mL and 1000-50,000 ng/mL.•Plasma samples were replaced with urine samples.
Arias, Angela; Corbella, Marc; Fons, Carmen; Sempere, Angela; García-Villoria, Judit; Ormazabal, Aida; Poo, Pilar; Pineda, Mercé; Vilaseca, María Antonia; Campistol, Jaume; Briones, Paz; Pàmpols, Teresa; Salomons, Gajja S; Ribes, Antonia; Artuch, Rafael
2007-11-01
To report the prevalence of creatine transporter deficiency in males with mental retardation and to study whether a protein-rich food intake might be a potential diagnostic pitfall. We determined creatine/creatinine ratio in urine samples from 1600 unrelated male patients with mental retardation and/or autism. Urine creatine was analyzed by HPLC-MS/MS. Thirty-three of 1600 cases showed increased urine creatine/creatinine ratio. Four out of these thirty-three cases were definitively diagnosed with creatine transporter deficiency, while the other 29 were false positive results. Significantly higher values were observed for urine Cr/Crn ratio in healthy volunteers after a meal based on beef or oily fish as compared to eggs, pasta or salad (Wilcoxon test: p<0.005). False positive results may be observed in biochemical screening for creatine transporter deficiency, and they may be due to intake of meals rich in creatine prior to urine samples analysis.
Luong, Susan; Kuzhiumparambil, Unnikrishnan; Fu, Shanlin
2015-09-17
Currently, procedures that identify the drugs 'destroyed' in adulterated urine specimens are very limited. This study aimed to determine the effect of pyridinium chlorochromate (PCC) on routine opiate assays and identify reaction products formed. Results/methodology: Opiate-positive urines adulterated with PCC (20 and 100 mM) were analyzed using CEDIA ® immunoassay and GC-MS. Urine and water samples spiked with 6-monoacetylmorphine, morphine and its glucuronides (10 µg/ml) and PCC (0.02-100 mM) were monitored with LC-MS, and the products characterized. PCC significantly decreased the abundance of morphine, codeine and IS. Adulterated water and urine samples containing 6-monoacetylmorphine, morphine and morphine-3-glucuronide yielded morphinone-3-glucuronide, 7,14-dihydroxy-6-monoacetylmorphine, 7,8-diketo-6-monoacetylmorphine and 7,8-diketo-morphine (tentative assignment). Reaction pathways may be different in the two matrices.
NASA Astrophysics Data System (ADS)
Xu, B. Y.; Ye, Y.; Liao, L. C.
2016-07-01
A new method was developed to determine the methamphetamine and morphine concentrations in urine and saliva based on excitation-emission matrix fluorescence coupled to a second-order calibration algorithm. In the case of single-drug abuse, the results showed that the average recoveries of methamphetamine and morphine were 95.3 and 96.7% in urine samples, respectively, and 98.1 and 106.2% in saliva samples, respectively. The relative errors were all below 5%. The simultaneous determination of methamphetamine and morphine in urine using two second-order algorithms was also investigated. Satisfactory results were obtained with a self-weighted alternating trilinear decomposition algorithm. The root-mean-square errors of the predictions were 0.540 and 0.0382 μg/mL for methamphetamine and morphine, respectively. The limits of detection of the proposed methods were very low and sufficient for studying methamphetamine and morphine in urine.
Nutrition and Repository: Insertion of Urine Sample into MELFI
2009-04-18
ISS019-E-010170 (18 April 2009) --- Astronaut Michael Barratt, Expedition 19/20 flight engineer, performs an insertion of urine samples into the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) study in the Japanese Kibo laboratory of the International Space Station.
Nutrition and Repository: Insertion of Urine Sample into MELFI
2009-04-18
ISS019-E-010165 (18 April 2009) --- Astronaut Michael Barratt, Expedition 19/20 flight engineer, performs an insertion of urine samples into the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) study in the Japanese Kibo laboratory of the International Space Station.
de Jager, Andrew D; Bailey, Neville L
2011-09-01
A rapid LC-MS/MS method for confirmatory testing of five major categories of drugs of abuse (amphetamine-type substances, opiates, cocaine, cannabis metabolites and benzodiazepines) in urine has been developed. All drugs of abuse mandated by the Australian/New Zealand Standard AS/NZS 4308:2008 are quantified in a single chromatographic run. Urine samples are diluted with a mixture of isotope labelled internal standards. An on-line trap-and-flush approach, followed by LC-ESI-MS/MS has been successfully used to process samples in a functioning drugs of abuse laboratory. Following injection of diluted urine samples, compounds retained on the trap cartridge are flushed onto a reverse-phase C18 HPLC column (5-μm particle size) with embedded hydrophylic functionality. A total chromatographic run-time of 15 min is required for adequate resolution. Automated quantitation software algorithms have been developed in-house using XML scripting to partially automate the identification of positive samples, taking into account ion ratio (IR) and retention times (Rt). The sensitivity of the assay was found to be adequate for the quantitation of drugs in urine at and below the confirmation cut-off concentrations prescribed by AS/NZS 4308:2008. Copyright © 2011 Elsevier B.V. All rights reserved.
Ximenes, Camila; Brandão, Eduardo; Oliveira, Paula; Rocha, Abraham; Rego, Tamisa; Medeiros, Rafael; Aguiar-Santos, Ana; Ferraz, João; Reis, Christian; Araujo, Paulo; Carvalho, Luiz; Melo, Fabio L
2014-12-01
The Global Program for the Elimination of Lymphatic Filariasis (GPELF) aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR)-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2) and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2), which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.
An aggregate urine analysis tool to detect acute dehydration.
Hahn, Robert G; Waldréus, Nana
2013-08-01
Urine sampling has previously been evaluated for detecting dehydration in young male athletes. The present study investigated whether urine analysis can serve as a measure of dehydration in men and women of a wide age span. Urine sampling and body weight measurement were undertaken before and after recreational physical exercise (median time: 90 min) in 57 volunteers age 17-69 years (mean age: 42). Urine analysis included urine color, osmolality, specific gravity, and creatinine. The volunteers' body weight decreased 1.1% (mean) while they exercised. There were strong correlations between all 4 urinary markers of dehydration (r = .73-.84, p < .001). Researchers constructed a composite dehydration index graded from 1 to 6 based on these markers. This index changed from 2.70 before exercising to 3.55 after exercising, which corresponded to dehydration of 1.0% as given by a preliminary reference curve based on seven previous studies in athletes. Men were slightly dehydrated at baseline (mean: 1.9%) compared with women (mean: 0.7%; p < .001), though age had no influence on the results. A final reference curve that considered both the present results and the 7 previous studies was constructed in which exercise-induced weight loss (x) was predicted by the exponential equation x = 0.20 dehydration index1.86. Urine sampling can be used to estimate weight loss due to dehydration in adults up to age 70. A robust dehydration index based on four indicators reduces the influence of confounders.
Atacag, T; Yayci, E; Guler, T; Suer, K; Yayci, F; Deren, S; Cetin, A
2015-01-01
The objective of this study was to assess the frequency of urinary tract infection (UTI) with urine samples obtained via catheterization among women undergoing cesarean delivery at term pregnancy. A cross-sectional study involving 159 women in whom cesarean delivery was conducted at term pregnancy after a regular follow-up from first to third trimester. For screening and diagnosis of UTI during antenatal period, the authors used dipstick test and microscopic urinalysis, and urine culture was used in the presence of symptomatic UTI unresponsive to initial antibiotic therapy. A urine sample was obtained immediately after insertion of Foley catheter for urine dipstick test, microscopic urinalysis, and culture during cesarean delivery. Obstetric and UTI data were recorded. Of 159 pregnant women, 95 (59.8%) did not develop UTI during antenatal care. There was no patient with symptomatic UTI at the admission for cesarean delivery. The authors found UTI with urine dipstick and microscopic urinalysis in 12 patients and of them, four patients had no history of UTI, and all the remaining eight patients had asymptomatic UTI during antenatal follow-up. UTI according to urine culture was encountered in three patients, two of them had one episode of UTI, and one had two episodes of UTI during antenatal follow-up. After regular antenatal follow-up screening with urine dipstick, microscopic urinalysis, and counseling of pregnant women regarding UTIs, the frequency of bacteriuria decreases considerably during cesarean delivery.
Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine
2013-01-01
Introduction. Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining 1H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. Methods. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after 1H NMR spectroscopy. Results. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at −20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Conclusion. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions. PMID:23865070
Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine
2013-01-01
Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining (1)H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after (1)H NMR spectroscopy. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at -20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions.
Seiwert, Bettina; Karst, Uwe
2007-09-15
A method for the simultaneous determination of a series of thiols and disulfides in urine samples has been developed based on the sequential labeling of free and bound thiol functionalities with two ferrocene-based maleimide reagents. The sample is first exposed to N-(2-ferroceneethyl)maleimide, thus leading to the derivatization of free thiol groups in the sample. After quantitative reaction and subsequent reduction of the disulfide-bound thiols by tris(2-carboxyethyl)phosphine, the newly formed thiol functionalities are reacted with ferrocenecarboxylic acid-(2-maleimidoyl)ethylamide. The reaction products are determined by LC/MS/MS in the multiple reaction mode, and precursor ion scan as well as neutral loss scan is applied to detect unknown further thiols. The method was successfully applied to the analysis of free and disulfide-bound thiols in urine samples. Limits of detection are 30 to 110 nM, and the linear range comprises two decades of concentration, thus covering the relevant concentration range of thiols in urine samples. The thiol and disulfide concentrations were referred to the creatinine content to compensate for different sample volumes. As some calibration standards for the disulfides are not commercially available, they were synthesized in an electrochemical flow-through cell. This allowed the synthesis of hetero- and homodimeric disulfides.
Mizéhoun-Adissoda, Carmelle; Houehanou, Corine; Chianéa, Thierry; Dalmay, François; Bigot, André; Preux, Pierre-Marie; Bovet, Pascal; Houinato, Dismand; Desport, Jean-Claude
2016-07-01
The 24-hour urine collection method is considered the gold standard for the estimation of ingested potassium and sodium. Because of the impracticalities of collecting all urine over a 24-hour period, spot urine is often used for epidemiological investigations. This study aims to assess the agreement between spot urine and 24-hour urine measurements to determine sodium and potassium intake. A total of 402 participants aged 25 to 64 years were randomly selected in South Benin. Spot urine was taken during the second urination of the day. Twenty-four-hour urine was also collected. Samples (2-mL) were taken and then stored at -20°C. The analysis was carried out using potentiometric dosage. The agreement between spot urine and 24-hour urine measurements was established using Bland-Altman plots. A total of 354 results were analyzed. Daily sodium chloride and potassium chloride urinary excretion means were 10.2±4.9 g/24 h and 2.9±1.4 g/24 h, respectively. Estimated daily sodium chloride and potassium chloride means from the spot urine were 10.7±7.0 g/24 h and 3.9±2.1 g/24 h, respectively. Concordance coefficients were 0.61 at d=-0.5 g, (d±2SD=-11 g and 10.1 g) for sodium chloride and 0.61 at d=-1 g, (d±2SD=-3.8 g and 1.8 g) for potassium chloride. Spot urine method is acceptable for estimating 24-hour urinary sodium and potassium excretion to assess sodium and potassium intake in a black population. However, the confidence interval for the mean difference, which is too large, makes the sodium chloride results inadmissible at a clinical level. © 2015 Wiley Periodicals, Inc.
SELDI-TOF-MS proteomic profiling of serum, urine, and amniotic fluid in neural tube defects.
Liu, Zhenjiang; Yuan, Zhengwei; Zhao, Qun
2014-01-01
Neural tube defects (NTDs) are common birth defects, whose specific biomarkers are needed. The purpose of this pilot study is to determine whether protein profiling in NTD-mothers differ from normal controls using SELDI-TOF-MS. ProteinChip Biomarker System was used to evaluate 82 maternal serum samples, 78 urine samples and 76 amniotic fluid samples. The validity of classification tree was then challenged with a blind test set including another 20 NTD-mothers and 18 controls in serum samples, and another 19 NTD-mothers and 17 controls in urine samples, and another 20 NTD-mothers and 17 controls in amniotic fluid samples. Eight proteins detected in serum samples were up-regulated and four proteins were down-regulated in the NTD group. Four proteins detected in urine samples were up-regulated and one protein was down-regulated in the NTD group. Six proteins detected in amniotic fluid samples were up-regulated and one protein was down-regulated in the NTD group. The classification tree for serum samples separated NTDs from healthy individuals, achieving a sensitivity of 91% and a specificity of 97% in the training set, and achieving a sensitivity of 90% and a specificity of 97% and a positive predictive value of 95% in the test set. The classification tree for urine samples separated NTDs from controls, achieving a sensitivity of 95% and a specificity of 94% in the training set, and achieving a sensitivity of 89% and a specificity of 82% and a positive predictive value of 85% in the test set. The classification tree for amniotic fluid samples separated NTDs from controls, achieving a sensitivity of 93% and a specificity of 89% in the training set, and achieving a sensitivity of 90% and a specificity of 88% and a positive predictive value of 90% in the test set. These suggest that SELDI-TOF-MS is an additional method for NTDs pregnancies detection.
Xiang, P; Bu, J; Qiao, Z; Zhuo, X Y; Wu, H J; Shen, M
2017-12-01
To study the content variation of selegiline and its metabolites in urine, and based on actual cases, to explore the feasibility for the identification of methamphetamine abuse and selegiline use by chiral analysis. The urine samples were tested by chiral separation and LC-MS/MS method using CHIROBIOTIC™ V2 chiral liquid chromatography column. The chiral analysis of methamphetamine and amphetamine were performed on the urine samples from volunteers of selegiline use and drug addicts whom suspected taking selegiline. After 5 mg oral administration, the positive test time of selegiline in urine was less than 7 h. The mass concentrations of R(-)-methamphetamine and R(-)-amphetamine in urine peaked at 7 h which were 0.86 μg/mL and 0.18 μg/mL and couldn't be detected after 80 h and 168 h, respectively. The sources of methamphetamine and amphetamine in the urine from the drug addicts whom suspected taking selegiline were analysed successfully by present method. The chiral analysis of methamphetamine and amphetamine, and the determination of selegiline's metabolites can be used to distinguish methamphetamine abuse from selegiline use. Copyright© by the Editorial Department of Journal of Forensic Medicine
Monitoring cocaine use and abstinence among cocaine users for contingency management interventions.
Holtyn, August F; Knealing, Todd W; Jarvis, Brantley P; Subramaniam, Shrinidhi; Silverman, Kenneth
2017-06-01
During contingency management interventions, reinforcement of cocaine abstinence is arranged by delivering an incentive when a urine sample tests cocaine-negative. The use of qualitative versus quantitative urinalysis testing may have important implications for effects on cocaine abstinence. Qualitative testing (i.e., testing that solely identifies whether a particular substance is present or absent) may not detect short-term cocaine abstinence because a single instance of cocaine use can result in cocaine-positive urine over many days. Quantitative testing (i.e., testing that identifies how much of a substance is present) may be more sensitive to short-term cocaine abstinence; however, the selection of a criterion for distinguishing new use versus carryover from previous use is an important consideration. The present study examined benzoylecgonine concentrations, the primary metabolite of cocaine, in urine samples collected three times per week for 30 weeks from 28 cocaine users who were exposed to a cocaine abstinence contingency. Of the positive urine samples (benzoylecgonine concentration >300 ng/ml), 29%, 21%, 14%, and 5% of the samples decreased in benzoylecgonine concentration by more than 20%, 40%, 60%, and 80% per day, respectively. As the size of the decrease increased, the likelihood of that sample occurring during a period leading to a cocaine-negative urine sample (benzoylecgonine concentration ≤300 ng/ml) also increased. The number of days required to produce a cocaine-negative sample following a positive sample ranged from 1 to 10 days and was significantly correlated with the starting benzoylecgonine level ( r = 0.43, p < 0.001). The present analyses may aid in the development of procedures that allow for the precise reinforcement of recent cocaine abstinence during contingency management interventions.
Survey of antibiotic residues in Canadian slaughter animals.
Tittiger, F; Kingscote, B; Meldrum, B; Prior, M
1975-01-01
Kidneys and urine of cattle, swine, sheep and chickens were tested for bacterial growth inhibitors using Bacillus subtilis and Sarcina lutea as test organisms. Results were as follows: 211 beef kidneys four positive, 611 swine kidneys five positive, 27 sheep and 120 chicken kidneys all negative, 2108 beef urine 76 positive, 2409 swine urine 186 positive, 176 sheep urine 17 positive. Strongest reactions were obtained with B. subtilis on phosphate buffered pH 6.0 plates. Larger zones were produced by urine from injected animals than by tissue samples. PMID:236082
Simple sampling strategy for measuring inulin renal clearance.
Horio, Masaru; Imai, Enyu; Yasuda, Yoshinari; Hishida, Akira; Matsuo, Seiichi
2009-02-01
In the standard method of inulin clearance (Cin), three sets of serum and urine samples are collected during a 2-hour clearance period. For a practical use of this method, sampling should be the minimal number allowable while still providing enough accuracy. The aim of this study was to evaluate the validity of inulin renal clearance with assumed single urine collection with a period such as 30, 60 or 90 minutes. Inulin clearance data collected by the standard method from 737 individuals were used. Changes of serum inulin concentrations between 45 and 105 minutes after the start of the infusion were analyzed. We used first urine collection to calculate the inulin clearance with single urine collection (Cin-30 min). We assumed single urine collection for 60 or 90 minutes by combining the urine data of the consecutive 30-minute periods. Inulin clearances (Cin-60 min, Cin-90 min) were calculated from the assumed single urine collections, respectively. Serum inulin concentration did not reach equilibrium during the clearance period. It increased in subjects with low glomerular filtration rate (GFR) and decreased in subjects with normal GFR. The amount of the change was small and -0.5 +/- 12.6% in subjects with GFR over 30 ml/min per 1.73 m(2). Cin-30 min, Cin-60 min and Cin-90 min showed high correlation coefficients against Cin-ST (0.962, 0.988 and 0.998, respectively). Systemic biases in these clearances were negligible (under 1 ml/min per 1.73 m(2)). Root mean square error (RMSE) were 10.4, 5.3 and 2.3 ml/min per 1.73 m(2) for Cin-30 min, Cin-60 min and Cin-90 min, respectively. These data indicated that accuracy of inulin clearance depends on the duration of the urine collection period. Inulin clearance with a single urine collection is a convenient method. We showed that single urine collection for 30 minutes or a longer period has reasonable accuracy in calculation of inulin clearance. We propose a method of inulin clearance with single urine collection for 60 minutes.
Mazzarino, Monica; Abate, Maria Gabriella; Alocci, Roberto; Rossi, Francesca; Stinchelli, Raffaella; Molaioni, Francesco; de la Torre, Xavier; Botrè, Francesco
2011-01-10
The presence of microorganisms in urine samples, under favourable conditions of storage and transportation, may alter the concentration of steroid hormones, thus altering the correct evaluation of the urinary steroid profile in doping control analysis. According to the rules of the World Anti-Doping Agency (WADA technical document TD2004 EAAS), a testosterone deconjugation higher than 5% and the presence of 5α-androstane-3,17-dione and 5β-androstane-3,17-dione in the deconjugated fraction, are reliable indicators of urine degradation. The determination of these markers would require an additional quantitative analysis since the steroids screening analysis, in anti-doping laboratories, is performed in the total (free+conjugated) fraction. The aim of this work is therefore to establish reliable threshold values for some representative compounds (namely 5α-androstane-3,17-dione and 5β-androstane-3,17-dione) in the total fraction in order to predict directly at the screening stage the potential microbial degradation of the urine samples. Preliminary evidence on the most suitable degradation indexes has been obtained by measuring the urinary concentration of testosterone, epitestosterone, 5α-androstane-3,17-dione and 5β-androstane-3,17-dione by gas chromatography-mass spectrometric every day for 15 days in the deconjugated, glucuronide and total fraction of 10 pools of urines from 60 healthy subjects, stored under different pH and temperature conditions, and isolating the samples with one or more markers of degradation according to the WADA technical document TD2004EAAS. The threshold values for 5α-androstane-3,17-dione and 5β-androstane-3,17-dione were therefore obtained correlating the testosterone deconjugation rate with the urinary concentrations of 5α-androstane-3,17-dione and 5β-androstane-3,17-dione in the total fraction. The threshold values suggested as indexes of urine degradation in the total fraction were: 10 ng mL(-1) for 5α-androstane-3,17-dione and 20 ng mL(-1) for 5β-androstane-3,17-dione. The validity of this approach was confirmed by the analysis of routine samples for more than five months (i.e. on a total of more than 4000 urine samples): samples with a concentration of total 5α-androstane-3,17-dione and 5β-androstane-3,17-dione higher than the threshold values showed a percentage of free testosterone higher than 5 of its total amount; whereas free testosterone in a percentage higher than 5 of its total amount was not detected in urines with a concentration of total 5α-androstane-3,17-dione and 5β-androstane-3,17-dione lower than the threshold values. Copyright © 2010 Elsevier B.V. All rights reserved.
The cocaine cutting agent levamisole is frequently detected in cocaine users.
Pope, Jeffrey D; Drummer, Olaf H; Schneider, Hans G
2018-06-21
Cocaine use in Australia is increasing, with approximately 2.5% of the surveyed population having used cocaine. In the USA, levamisole, a widely used anti-helminthic veterinary drug has been increasingly detected as a cutting agent in cocaine seizures. Levamisole is known to cause agranulocytosis in humans. We ascertained the prevalence of levamisole-adulterated cocaine, detectable in the urine from patients that had undergone a pathology request for a urine drug screen. We assayed routinely requested urines that were positive for cocaine on immunoassay with liquid chromatography high resolution quadrupole time of flight mass spectrometry (LC-QToF). We investigated available urine samples from a period of 2 years that had a positive result for cocaine. In addition, we examined samples that were below the cut-off for cocaine on immunoassay. Specimens were analysed for the presence of levamisole and other 'unknown' drugs. In the period under investigation the laboratory examined 3665 urine samples for cocaine: 1.4% (n = 51) of the samples were positive for cocaine by immunoassay and half of these (n = 26, 51%) were further examined by LC-QToF. In addition, we examined 10 samples that were negative by immunoassay (as defined by AS/NZS 4308:2008). Levamisole was detected in the urine of cocaine users in approximately 75% of cases. Other illicit drugs were also frequently found in this cohort. The most common illicit drugs detected were methamphetamine, ecstasy and cannabis. Australian cocaine is widely adulterated with levamisole. Cocaine users are at risk of levamisole related health problems in addition to the problems related to cocaine. Copyright © 2018 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.
Urinary Volatile Organic Compounds for the Detection of Prostate Cancer
Khalid, Tanzeela; Aggio, Raphael; White, Paul; De Lacy Costello, Ben; Persad, Raj; Al-Kateb, Huda; Jones, Peter; Probert, Chris S.; Ratcliffe, Norman
2015-01-01
The aim of this work was to investigate volatile organic compounds (VOCs) emanating from urine samples to determine whether they can be used to classify samples into those from prostate cancer and non-cancer groups. Participants were men referred for a trans-rectal ultrasound-guided prostate biopsy because of an elevated prostate specific antigen (PSA) level or abnormal findings on digital rectal examination. Urine samples were collected from patients with prostate cancer (n = 59) and cancer-free controls (n = 43), on the day of their biopsy, prior to their procedure. VOCs from the headspace of basified urine samples were extracted using solid-phase micro-extraction and analysed by gas chromatography/mass spectrometry. Classifiers were developed using Random Forest (RF) and Linear Discriminant Analysis (LDA) classification techniques. PSA alone had an accuracy of 62–64% in these samples. A model based on 4 VOCs, 2,6-dimethyl-7-octen-2-ol, pentanal, 3-octanone, and 2-octanone, was marginally more accurate 63–65%. When combined, PSA level and these four VOCs had mean accuracies of 74% and 65%, using RF and LDA, respectively. With repeated double cross-validation, the mean accuracies fell to 71% and 65%, using RF and LDA, respectively. Results from VOC profiling of urine headspace are encouraging and suggest that there are other metabolomic avenues worth exploring which could help improve the stratification of men at risk of prostate cancer. This study also adds to our knowledge on the profile of compounds found in basified urine, from controls and cancer patients, which is useful information for future studies comparing the urine from patients with other disease states. PMID:26599280
Postal urine specimens: are they a feasible method for genital chlamydial infection screening?
Macleod, J; Rowsell, R; Horner, P; Crowley, T; Caul, E O; Low, N; Smith, G D
1999-01-01
BACKGROUND: A United Kingdom (UK) screening programme for Chlamydia trachomatis has recently been announced. Pilot projects involving the opportunistic testing of women attending health facilities are due to commence in several sites. There is a danger that this approach will fail to obtain adequate population coverage. The alternative--true systematic population screening--is generally assumed to be unfeasible. Studies in Denmark using postal urine specimens have challenged this assumption. No such studies have been reported from the UK. AIM: To assess the potential of urine specimens sent by post as the basis for a UK population screening strategy for genital chlamydial infection. METHOD: Two hundred patients (100 men, 100 women) aged 18 to 45 years were randomly sampled from the list of one urban group practice. Subjects were mailed an explanatory letter, a urine sample container, a sexual lifestyle questionnaire, and a prepaid return envelope. Non-responders were contacted by telephone; persistent non-responders were visited at home. Samples were tested for Chlamydia by DNA amplification and enzyme immunoassay. RESULTS: Sixty-four (32%) subjects were no longer living at their GP registered address. Of the remaining 136, 126 (93%) responded to the survey and 113 (83%) accepted the request for a urine sample and completed a questionnaire. Acceptance rates were similar for men and women and across age groups. Four samples (3%) were Chlamydia positive. CONCLUSION: Home mailed urine specimen collection in conjunction with a self-completed postal questionnaire is feasible. This could provide a viable basis both for determining population Chlamydia prevalence and for a UK Chlamydia population screening strategy. Overall cost effectiveness of such a strategy will depend on the cost of the test used. Comparative performance characteristics of the different currently available tests in this setting have yet to be fully determined. PMID:10562745
Jones, Kelli; Turner, Bradley; Brandão, João; Hubbard, Sue Ann; Magee, Danny; Baughman, Brittany; Wills, Robert; Tully, Thomas
2015-06-01
Hen diuresis syndrome has emerged over the past 5 yr as a significant cause of mortality in the U.S. broiler breeder industry. The condition affects hens in production and is characterized by transient muscle weakness in the vent region, transient diuresis, and often urate deposits on the skin below the vent. Affected hens are often seen straining to lay an egg, which suggests oviduct contraction is also impaired. Related hen mortality, often reaching 1% or more a week, is believed to be primarily the result of male aggression of the vent region (Turner et al., "Investigating Causes of Excessive Urate Production in Broiler Breeder Hens Associated with Peritonitis and Cannibalism Mortality," Oral Presentation at The American Association of Avian Pathologists Annual Meeting, p. 139, 2010). The exact association between the cause of mortality and this syndrome is unknown, but it may be the consequence of transient partial to full oviduct prolapse, which predisposes or stimulates cannibalism and aggression. Based on unpublished work done prior to this study (Turner et al., ibid.), the evidence suggests the underlying problem is metabolic. We feel that urine collection and analysis is an essential component to understanding this condition. This study serves as a pilot study for future investigations that attempt to identify the nature and cause of the metabolic disturbance through paired urine and serum collection and analysis. For the purpose of this study, a small sample of 10 affected and 10 unaffected birds was used for sample collection. In order to collect pure urine, the birds were surgically colostomized. Colostomy did prove to be a useful means of collecting urine free of feces, and for the purposes of our study it yielded adequate urine samples for analysis. There were statistically relevant urine values observed. Affected birds had a higher presence of blood in the urine, a lower uric acid excretion rate (mg/hr), higher concentration (mEq/L) of urine Na+, and a lower concentration (mEq/L) of urine K+ than unaffected birds. This pilot study helps to address some of the pitfalls previously associated with colostomy and to determine when collection can begin postoperatively so that we can better understand when and how to begin our sampling in future trials to address the etiology of this condition.
Stability of Drugs of Abuse in Urine Samples at Room Temperature by Use of a Salts Mixture.
Pellegrini, Manuela; Graziano, Silvia; Mastrobattista, Luisa; Minutillo, Adele; Busardo, Francesco Paolo; Scarsella, Gianfranco
2017-01-01
It has long been recognized that ensuring analyte stability is of crucial importance in the use of any quantitative bioanalytical method. As analyses are usually not performed directly after collection of the biological samples, but after these have been processed and stored, it is essential that analyte stability can be maintained at storage conditions to ensure that the obtained concentration results adequately reflect those directly after sampling. The conservation of urine samples in refrigerated/ frozen conditions is strongly recommended; but not always feasible. The aim of this study was to assess the stability of some well-known drugs of abuse methamphetamine (MA), 11-nor-9-carboxy-Δ9- tetrahydrocannabinol (THC-COOH), benzoylecgonine (BE), and morphine (MOR) in urine samples kept at room temperature by adding a salt mixture (sodium citrate, sodium ascorbate, borax). Two different urine samples were prepared with and without salt mixture, stored at room temperature and then analyzed by gas chromatography-mass spectrometry at 0, 1, 7, 15, and 30 days after collection/preparation to look for eventual analyte degradation. Methamphetamine showed no significant changes with respect to the time of collection/ preparation (T0) up to 7 days later (T7), with or without salt mixture addiction. Then a significant degradation occurred in both salted and non salted urine. BE decrease was observed starting from day 1 after sample collection in salted and not salted samples, respectively. Salt addition seemed to reduce at least the initial BE degradation, with a significant difference (p<0.001) at 7 and 15 days of storage. However, the degradation was not more prevented in salted samples at 30 days of storage. A 20% decrease of MOR concentration was observed starting from day 1 after collection/preparation, both in salted and not salted samples with no subsequent decrease. With regard to THCCOOH, a significant decrease was observed starting from 7 days after collection/preparation, with of without adding the salt mixture. However, when comparing salted versus non salted samples at each time point, a statistically significant difference was observed at 7 and 30 days of storage. The results obtained indicate that the degradation of MA, THC-COOH and BE in urine samples kept at room temperature can be slowed by the addition of the salt mixture, whereas it seems to be ineffective in samples containing MOR. This evidence has to be taken into account, in the eventuality of using salted urine to prevent in a certain extent abuse of above-reported drugs of abuse. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Speciation of arsenic in biological samples.
Mandal, Badal Kumar; Ogra, Yasumitsu; Anzai, Kazunori; Suzuki, Kazuo T
2004-08-01
Speciation of arsenicals in biological samples is an essential tool to gain insight into its distribution in tissues and its species-specific toxicity to target organs. Biological samples (urine, hair, fingernail) examined in the present study were collected from 41 people of West Bengal, India, who were drinking arsenic (As)-contaminated water, whereas 25 blood and urine samples were collected from a population who stopped drinking As contaminated water 2 years before the blood collection. Speciation of arsenicals in urine, water-methanol extract of freeze-dried red blood cells (RBCs), trichloroacetic acid treated plasma, and water extract of hair and fingernail was carried out by high-performance liquid chromatography (HPLC)-inductively coupled argon plasma mass spectrometry (ICP MS). Urine contained arsenobetaine (AsB, 1.0%), arsenite (iAs(III), 11.3), arsenate (iAs(V), 10.1), monomethylarsonous acid (MMA(III), 6.6), monomethylarsonic acid (MMA(V), 10.5), dimethylarsinous acid (DMA(III), 13.0), and dimethylarsinic acid (DMA(V), 47.5); fingernail contained iAs(III) (62.4%), iAs(V) (20.2), MMA(V) (5.7), DMA(III) (8.9), and DMA(V) (2.8); hair contained iAs(III) (58.9%), iAs(V) (34.8), MMA(V) (2.9), and DMA(V) (3.4); RBCs contained AsB (22.5%) and DMA(V) (77.5); and blood plasma contained AsB (16.7%), iAs(III) (21.1), MMA(V) (27.1), and DMA(V) (35.1). MMA(III), DMA(III), and iAs(V) were not found in any plasma and RBCs samples, but urine contained all of them. Arsenic in urine, fingernails, and hair are positively correlated with water As, suggesting that any of these measurements could be considered as a biomarker to As exposure. Status of urine and exogenous contamination of hair urgently need speciation of As in these samples, but speciation of As in nail is related to its total As (tAs) concentration. Therefore, total As concentrations of nails could be considered as biomarker to As exposure in the endemic areas.
Küme, Tuncay; Sağlam, Barıs; Ergon, Cem; Sisman, Ali Rıza
2018-01-01
The aim of this study is to evaluate and compare the analytical performance characteristics of the two creatinine methods based on the Jaffe and enzymatic methods. Two original creatinine methods, Jaffe and enzymatic, were evaluated on Architect c16000 automated analyzer via limit of detection (LOD) and limit of quantitation (LOQ), linearity, intra-assay and inter-assay precision, and comparability in serum and urine samples. The method comparison and bias estimation using patient samples according to CLSI guideline were performed on 230 serum and 141 urine samples by analyzing on the same auto-analyzer. The LODs were determined as 0.1 mg/dL for both serum methods and as 0.25 and 0.07 mg/dL for the Jaffe and the enzymatic urine method respectively. The LOQs were similar with 0.05 mg/dL value for both serum methods, and enzymatic urine method had a lower LOQ than Jaffe urine method, values at 0.5 and 2 mg/dL respectively. Both methods were linear up to 65 mg/dL for serum and 260 mg/dL for urine. The intra-assay and inter-assay precision data were under desirable levels in both methods. The higher correlations were determined between two methods in serum and urine (r=.9994, r=.9998 respectively). On the other hand, Jaffe method gave the higher creatinine results than enzymatic method, especially at the low concentrations in both serum and urine. Both Jaffe and enzymatic methods were found to meet the analytical performance requirements in routine use. However, enzymatic method was found to have better performance in low creatinine levels. © 2017 Wiley Periodicals, Inc.
Higashi, Kyohei; Shibasaki, Mana; Kuni, Kyoshiro; Uemura, Takeshi; Waragai, Masaaki; Uemura, Kenichi; Igarashi, Kazuei; Toida, Toshihiko
2017-09-29
A three column-switching high-performance liquid chromatography (HPLC) using an electrochemical detector (ECD) equipped with a diamond electrode was established to determine 3-hydroxypropylmercapturic acid (3-HPMA) in urine. An extracted urine sample was consecutively fractionated using a strong anion-exchange column (first column) and a C8 column (second column) via a switching valve before application on an Octa Decyl Silyl (ODS) column (third column), followed by ECD analysis. The% recovery of 3-HPMA standard throughout the three-column process and limit of detection (LOD) were 94±1% and 0.1pmol, respectively. A solid phase extraction step is required for the sensitive analysis of 3-HPMA in urine by column-switching HPLC-ECD despite a decreased% recovery (55%) of urine sample spiked with 100pmol of 3-HPMA. To test the utility of our column-switching HPLC-ECD method, 3-HPMA levels of 27 urine samples were determined, and the correlation between HPLC-ECD and LC-Electrospray ionization (ESI)-MS/MS method was examined. As a result, the median values of μmol 3-HPMA/g Creatinine (Cre) in urine obtained by column-switching HPLC-ECD and LC-MS/MS were 2.19±2.12μmol/g Cre and 2.13±3.38μmol/g Cre, respectively, and the calibration curve (y=1.5171x-1.007) exhibited good linearity within a defined range (r 2 =0.907). These results indicate that the combination of column-switching HPLC and ECD is a powerful tool for the specific, reliable detection of 3-HPMA in urine. Copyright © 2017 Elsevier B.V. All rights reserved.
Reina, J; Weber, I; Riera, E; Busquets, M; Morales, C
2014-05-01
Cytomegalovirus (CMV) is the main virus causing congenital and postnatal infections in the pediatric population. The aim of this study is to evaluate the usefulness of a quantitative real-time PCR in the diagnosis of these infections using urine as a single sample. We studied all the urine samples of newborns (< 7 days) with suspected congenital infection, and urine of patients with suspected postnatal infection (urine negative at birth). Urines were simultaneously studied by cell culture, qualitative PCR (PCRc), and quantitative real-time PCR (PCRq). We analyzed 332 urine samples (270 to rule out congenital infection and 62 postnatal infections). Of the first, 22 were positive in the PCRq, 19 in the PCRc, and 17 in the culture. PCRq had a sensitivity of 100%, on comparing the culture with the rest of the techniques. Using the PCRq as a reference method, culture had a sensitivity of 77.2%, and PCRc 86.3%. In cases of postnatal infection, PCRq detected 16 positive urines, the PCRq 12, and the cell culture 10. The urines showed viral loads ranging from 2,178 to 116,641 copies/ml. The genomic amplification technique PCRq in real time was more sensitive than the other techniques evaluated. This technique should be considered as a reference (gold standard), leaving the cell culture as a second diagnostic level. The low cost and the automation of PCRq would enable the screening for CMV infection in large neonatal and postnatal populations. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Chen, Sheng-Hwang; Yu, Hsing-Yi; Hsu, Hsiu-Yueh; Lin, Fang-Chen; Lou, Jiunn-Horng
2013-11-01
The purpose of this study was to explore the relationship between organisational support, organisational identification, and organisational citizenship behaviour and the predictors of organisational citizenship behaviour in Taiwanese male nurses. The turnover rate among male nurses is twice that of female nurses. Organisational citizenship behaviour is the predictor of turnover intention. Little information is available on the relationship between organisational support, organisational identification and organisational citizenship behaviour, particularly for male nurses. Data were collected in 2010 from a questionnaire mailed to 167 male nurses in Taiwan. A cross-sectional survey with simple sampling was used in this study. The results showed that organisational identification and organisational support were correlated with organisational citizenship behaviour. Organisational distinctiveness, organisational support of work conditions and the type of organisation were the main predictors of organisational citizenship behaviour. Together they accounted for 40.7% of the total variation in organisational citizenship behaviour. Organisational distinctiveness was the most critical predictor, accounting for 29.6% of the variation. Organisational support and organisational identification have positive relationships with organisational behaviour. Organisational distinctiveness is an important factor in explaining organisational citizenship behaviour in male nurses. This finding provides concrete directions for managers to follow when providing organisational identification, in particular, the organisational distinctiveness will help male nurses to display increasingly more organisational citizenship behaviour. © 2012 John Wiley & Sons Ltd.
Evaluation of 1,5-anhydro-d-glucitol in clinical and forensic urine samples.
Sydow, Konrad; Wiedfeld, Christopher; Musshoff, Frank; Madea, Burkhard; Tschoepe, Diethelm; Stratmann, Bernd; Hess, Cornelius
2018-06-01
Because of the lack of characteristic morphological findings post mortem diagnosis of diabetes mellitus and identification of diabetic coma can be complicated. 1,5-Anhydroglucitol (1,5-AG), the 1-deoxy form of glucose, competes with glucose for renal reabsorption. Therefore low serum concentrations of 1,5-AG, reflect hyperglycemic excursions over the prior 1-2 weeks in diabetic patients. Next to clinical applications determination of 1,5-AG can also be used in forensic analysis. To investigate the elimination of 1,5-AG, a liquid chromatographic-mass spectrometric method for the determination of 1,5-AG and creatinine in urine was developed and validated according to international guidelines. To evaluate ante mortem concentrations of 1,5-AG spot urine samples of 30 healthy subjects, 46 type 1 and 46 type 2 diabetic patients were analyzed. 1,5-AG urine concentrations of diabetic patients were significantly (p<0.001) lower (mean: 1.54μg/ml, n=92) compared to concentrations of healthy subjects (mean: 4.76μg/ml, n=30) which led to the idea that 1,5-AG urine concentrations post mortem might help in the interpretation of a diabetic coma post mortem. Urine of 47 deceased non-diabetics, 37 deceased diabetic and 9 cases of diabetic coma were measured. Comparison of blood and urine 1,5-AG concentrations in clinic samples (linear, R 2 =0.13) and forensic samples (linear, R 2 =0.02) showed no correlation. Urinary levels of 1,5-AG in deceased diabetic (mean 6.9μg/ml) and in non-diabetic patients (mean 6.3μg/ml) did not show a significant difference (p=0.752). However, urinary 1,5-AG concentrations in deceased due to diabetic coma (mean: 1.7μg/ml) were significantly lower than in non-diabetic (mean: 6.3μg/ml, p=0.039) and lower than in diabetic cases (mean: 4.7μg/ml, p=0.058). The determination of a reliable cut-off for the differentiation of diabetic to diabetic coma cases was not possible. Normalization of urinary 1,5-AG concentrations with the respective creatinine concentrations did not show any gain of information. In clinical (serum) and forensic blood samples a significant difference between all groups could be detected (p<0.05). Comparison of blood and urine 1,5-AG concentrations in clinical samples (linear, R 2 =0.13) and forensic samples (linear, R 2 =0.02) showed no correlation. Copyright © 2018 Elsevier B.V. All rights reserved.
Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.
Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr
2014-01-07
To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.
Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases
Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr
2014-01-01
AIM: To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). METHODS: Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn’s disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student’s t test (α = 0.05). RESULTS: The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. CONCLUSION: NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission. PMID:24415869
Duenngai, Kunyarat; Wangboon, Chompunoot; Sithithaworn, Jiraporn; Watwiengkam, Nattaya; Namwat, Nisana; Techasen, Anchalee; Loilome, Watcharin; Yongvanit, Puangrat; Loukas, Alex; Sithithaworn, Paiboon; Bethony, Jeffrey M.
2015-01-01
Background Many strategies to control opisthorchiasis have been employed in Thailand, but not in the other neighbouring countries. Specific control methods include mass drug administration (MDA) and health education to reduce raw fish consumption. These control efforts have greatly shifted the epidemiology of Opisthorchis viverrini (OV) infection over the last decade from presenting as densely concentrated "heavy" infections in single villages to widespread "light" OV infections distributed over wide geographical areas. Currently, the "gold standard" detection method for OV infection is formalin ethyl-acetate concentration technique (FECT), which has limited diagnostic sensitivity and diagnostic specificity for light OV infections, with OV eggs often confused with eggs of minute intestinal flukes (MIFs) in feces. In this study, we developed and evaluated the diagnostic performance of a monoclonal antibody-based enzyme-linked immunosorbent assay for the measurement of OV excretory-secretory (ES) antigens in urine (urine OV-ES assay) for the diagnosis of opisthorchiasis compared to the gold standard detection FECT method. Methodology We tested several methods for pre-treating urine samples prior to testing the diagnostic performance of the urine OV-ES assay. Using trichloroacetic acid (TCA) pre-treated urine, we compared detection and quantification of OV infection using the urine OV-ES assay versus FECT in OV-endemic areas in Northeastern Thailand. Receiver operating characteristic (ROC) curves were used to determine the diagnostic sensitivity and specificity of the urine OV-ES assay using TCA pre-treated urine, and to establish diagnostic positivity thresholds. The Positive Predictive Value as well as the likelihood of obtaining a positive test result (LR+) or a negative test result (LR-) were calculated for the established diagnostic positivity threshold. Diagnostic risks (Odds Ratios) were estimated using logistic regression. Results When urine samples were pre-treated with TCA prior to use in the urine OV-ES assay, the analytical sensitivity was significantly improved. Using TCA pre-treatment of urine, the urine OV-ES assay had a limit of detection (LoD) of 39 ng/ml compared to the LoD of 52 ng/mL reported for coprological antigen detection methods. Similarly, the urine OV-ES assay correlated significantly with intensity of OV infection as measured by FECT. The urine OV-ES assay was also able to detect 28 individuals as positive from the 63 (44.4%) individuals previously determined to be negative using FECT. The likelihood of a positive diagnosis of OV infection by urine OV-ES assay increased significantly with the intensity of OV infection as determined by FECT. With reference to FECT, the sensitivity and specificity of the urine OV-ES assay was 81% and 70%, respectively. Conclusion The detection of OV-infection by the urine OV-ES assay showed much greater diagnostic sensitivity and diagnostic specificity than the current "gold standard" FECT method for the detection and quantification of OV infection. Due to its ease-of-use, and noninvasive sample collection (urine), the urine OV-ES assay offers the potential to revolutionize the diagnosis of liver fluke infection and provide an effective tool for control and elimination of these tumorigenic parasites. PMID:26485024
Do, Ha Thi Phuong; Santos, Joseph Alvin; Trieu, Kathy; Petersen, Kristina; Le, Mai Bach; Lai, Duc Truong; Bauman, Adrian; Webster, Jacqui
2016-11-01
This study evaluated the effectiveness of the Communication for Behavioral Impact (COMBI)-Eat Less Salt intervention conducted in Viet Tri, Vietnam. The behavior change intervention was implemented in four wards and four communes for one year, which included mass media communication, school interventions, community programs, and focus on high-risk groups. Mean sodium excretion was estimated from spot urine samples using different equations. A subsample provided 24-hour urine to validate estimates from spot urine. Information about salt-related knowledge and behaviors was also collected. There were 513 participants at both baseline and follow-up. Mean sodium excretion estimated from spot urines fell significantly from 8.48 g/d at baseline to 8.05 g/d at follow-up (P=.001). All spot equations demonstrated a significant reduction in sodium levels; however, the change was smaller than the measured 24-hour urine. Participants showed improved knowledge and behaviors following the intervention. The COMBI intervention was effective in lowering average population salt intake and improving knowledge and behaviors. ©2016 Wiley Periodicals, Inc.
Detection of Leptospiral DNA in the Urine of Donkeys on the Caribbean Island of Saint Kitts
Grevemeyer, Bernard; Vandenplas, Michel; Beigel, Brittney; Cho, Ellen; Willingham, Arve Lee; Verma, Ashutosh
2017-01-01
Leptospirosis is a global zoonosis caused by pathogenic spirochetes classified within the genus Leptospira. Leptospires live in the proximal renal tubules of reservoir or chronic carrier animals, and are shed in the urine. Naïve animals acquire infection either when they come in direct contact with a reservoir or infected animals or by exposure to environmental surface water or soil that is contaminated with their urine. In this study, urine samples from a herd of donkeys on the Caribbean island of St. Kitts were screened using a TaqMan-based real-time quantitative polymerase chain reaction (qPCR) targeting a pathogen-specific leptospiral gene, lipl32. Out of 124 clinically normal donkeys, 22 (18%) tested positive for leptospiral DNA in their urine. Water samples from two water troughs used by the donkeys were also tested, but were found to be free from leptospiral contamination. Detection of leptospiral DNA in the urine of clinically healthy donkeys may point to a role that these animals play in the maintenance of the bacteria on St. Kitts. PMID:29056661
Yoon, S; Pak, M-J; Park, S; Yoo, J; Ha, W-H; Jang, H-K; Kim, J K
2014-12-01
(32)P measurements of urine samples and internal dose assessments were conducted for workers in life science laboratories. A procedure for sample pre-treatment was established and validation was performed to exclude interference and to detect (32)P levels accurately. The detection conditions for Cherenkov radiation were evaluated and the accuracy of Cherenkov radiation measurements validated. The analytical and measurement procedures were applied to urine samples collected from 11 workers from life sciences laboratories. The results of the measurements generally indicated very low background radiation levels, but daily urine samples from two workers were above the minimum detectable activity. The (32)P concentrations for two of the workers were 29.3 ± 10.4 Bq•d(-1) and 24.1 ± 11.8 Bq•d(-1), respectively, at intake levels of 4.12 kBq and 2.61 kBq. The effective doses for these two workers were 4.6 μSv and 2.9 μSv. Overall, the results indicate very low levels of radioactivity, except for cases related to specific working conditions.
Sajid, Muhammad; Basheer, Chanbasha; Daud, Muhammad; Alsharaa, Abdulnaser
2017-03-17
In this work, the potential of layered double hydroxide/graphene (LDH-G) hybrid as a sorbent for extraction and preconcentration of fifteen organochlorine pesticides (OCPs) in urine samples was evaluated. The LDH-G hybrid was synthesized by co-precipitation method and it was then characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, transmission electron microscopy and X-ray diffraction. The sorbent was then employed in membrane-protected stir-bar supported micro-solid-phase extraction (SB-μ-SPE) of OCPs in urine samples. This extraction approach is highly suitable for the samples representing matrix complexity such as urine because the sorbent is effectively protected inside the membrane. The extracted samples were analyzed by gas chromatography mass spectrometry. The factors that affect the performance of SB-μ-SPE were suitably optimized. This method demonstrated good linearity with coefficients of determination up to 0.9996. The limits of detection ranged between 0.22 and 1.38ngmL -1 . The RSD values for intra and inter-day precision were also in a satisfactory range (2.7-9.5%). Copyright © 2017 Elsevier B.V. All rights reserved.
Van Keer, Severien; Pattyn, Jade; Tjalma, Wiebren A A; Van Ostade, Xaveer; Ieven, Margareta; Van Damme, Pierre; Vorsters, Alex
2017-09-01
Great interest has been directed towards the use of first-void urine as a liquid biopsy for high-risk human papillomavirus DNA testing. Despite the high correlations established between urinary and cervical infections, human papillomavirus testing is unable to distinguish between productive and transforming high-risk infections that have the tendency to progress to cervical cancer. Thus far, investigations have been primarily confined to the identification of biomarkers for triage of high-risk human papillomavirus-positive women in cervicovaginal specimens and tissue biopsies. This paper reviews urinary biomarkers for cervical cancer and triage of high-risk human papillomavirus infections and elaborates on the opportunities and challenges that have emerged regarding the use of first-void urine as a liquid biopsy for the analysis of both morphological- (conventional cytology and novel immunohistochemical techniques) and molecular-based (HPV16/18 genotyping, host/viral gene methylation, RNA, and proteins) biomarkers. A literature search was performed in PubMed and Web of Science for studies investigating the use of urine as a biomarker source for cervical cancer screening. Five studies were identified reporting on biomarkers that are still in preclinical exploratory or clinical assay development phases and on assessments of non-invasive (urine) samples. Although large-scale validation studies are still needed, we conclude that methylation of both host and viral genes in urine has been proven feasible for use as a molecular cervical cancer triage and screening biomarker in phase two studies. This is especially promising and underscores our hypothesis that human papillomavirus DNA and candidate human and viral biomarkers are washed away with the initial, first-void urine, together with exfoliated cells, debris and impurities that line the urethra opening. Similar to the limitations of self-collected cervicovaginal samples, first-void urine will likely not fulfil the high-quality cellularity standards required for morphological biomarkers. Molecular biomarkers will likely overcome this issue to yield high-throughput, objective, and reproducible results. When using proper sampling, transport, storage, preanalytical biomarker concentration techniques, and clinically validated assays, first-void urine is expected to be a valuable source of molecular biomarkers for cervical cancer screening. Furthermore, as first-void urine can be easily and non-invasively collected, it is a highly preferred technique among women and offers the ability to test both primary high-risk human papillomavirus and biomarkers in the same sample. In addition, the use of first-void urine confers opportunities to reduce loss-to follow-up and non-adherence to screening subjects. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Tsui, Nancy B. Y.; Jiang, Peiyong; Chow, Katherine C. K.; Su, Xiaoxi; Leung, Tak Y.; Sun, Hao; Chan, K. C. Allen; Chiu, Rossa W. K.; Lo, Y. M. Dennis
2012-01-01
Background Fetal DNA in maternal urine, if present, would be a valuable source of fetal genetic material for noninvasive prenatal diagnosis. However, the existence of fetal DNA in maternal urine has remained controversial. The issue is due to the lack of appropriate technology to robustly detect the potentially highly degraded fetal DNA in maternal urine. Methodology We have used massively parallel paired-end sequencing to investigate cell-free DNA molecules in maternal urine. Catheterized urine samples were collected from seven pregnant women during the third trimester of pregnancies. We detected fetal DNA by identifying sequenced reads that contained fetal-specific alleles of the single nucleotide polymorphisms. The sizes of individual urinary DNA fragments were deduced from the alignment positions of the paired reads. We measured the fractional fetal DNA concentration as well as the size distributions of fetal and maternal DNA in maternal urine. Principal Findings Cell-free fetal DNA was detected in five of the seven maternal urine samples, with the fractional fetal DNA concentrations ranged from 1.92% to 4.73%. Fetal DNA became undetectable in maternal urine after delivery. The total urinary cell-free DNA molecules were less intact when compared with plasma DNA. Urinary fetal DNA fragments were very short, and the most dominant fetal sequences were between 29 bp and 45 bp in length. Conclusions With the use of massively parallel sequencing, we have confirmed the existence of transrenal fetal DNA in maternal urine, and have shown that urinary fetal DNA was heavily degraded. PMID:23118982
Urine specimen validity test for drug abuse testing in workplace and court settings.
Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun
2018-01-01
In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.
Urine podocyte mRNAs mark disease activity in IgA nephropathy
Fukuda, Akihiro; Sato, Yuji; Iwakiri, Takashi; Komatsu, Hiroyuki; Kikuchi, Masao; Kitamura, Kazuo; Wiggins, Roger C.; Fujimoto, Shouichi
2015-01-01
Background Podocyte depletion is a major mechanism driving glomerulosclerosis. We and others have previously projected from model systems that podocyte-specific mRNAs in the urine pellet might serve as glomerular disease markers. We evaluated IgA nephropathy (IgAN) to test this concept. Methods From 2009 to 2013, early morning voided urine samples and kidney biopsies from IgAN patients (n = 67) were evaluated in comparison with urine samples from healthy age-matched volunteers (n = 28). Urine podocyte (podocin) mRNA expressed in relation to either urine creatinine concentration or a kidney tubular marker (aquaporin 2) was tested as markers. Results Urine podocyte mRNAs were correlated with the severity of active glomerular lesions (segmental glomerulosclerosis and acute extracapillary proliferation), but not with non-glomerular lesions (tubular atrophy/interstitial fibrosis) or with clinical parameters of kidney injury (serum creatinine and estimated glomerular filtration rate), or with degree of accumulated podocyte loss at the time of biopsy. In contrast, proteinuria correlated with all histological and clinical markers. Glomerular tuft podocyte nuclear density (a measure of cumulative podocyte loss) correlated with tubular atrophy/interstitial fibrosis, estimated-glomerular filtration rate and proteinuria, but not with urine podocyte markers. In a subset of the IgA cohort (n = 19, median follow-up period = 37 months), urine podocyte mRNAs were significantly decreased after treatment, in contrast to proteinuria which was not significantly changed. Conclusions Urine podocyte mRNAs reflect active glomerular injury at a given point in time, and therefore provide both different and additional clinical information that can complement proteinuria in the IgAN decision-making paradigm. PMID:25956757
High-throughput quantitative analysis by desorption electrospray ionization mass spectrometry.
Manicke, Nicholas E; Kistler, Thomas; Ifa, Demian R; Cooks, R Graham; Ouyang, Zheng
2009-02-01
A newly developed high-throughput desorption electrospray ionization (DESI) source was characterized in terms of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PRN) with PRN-d(7) as internal standard (IS) and carbamazepine (CBZ) with CBZ-d(10) as IS were examined. So were two other sample sets consisting of PRN/PRN-d(7) at varying concentration in a biological milieu of 10% urine or porcine brain total lipid extract, total lipid concentration 250 ng/microL. The background-free samples, examined in a total analysis time of 1.5 s/sample, showed good quantitative accuracy and precision, with a relative error (RE) and relative standard deviation (RSD) generally less than 3% and 5%, respectively. The samples in urine and the lipid extract required a longer analysis time (2.5 s/sample) and showed RSD values of around 10% for the samples in urine and 4% for the lipid extract samples and RE values of less than 3% for both sets. The LOD for PRN and CBZ when analyzed without chemical background was 10 and 30 fmol, respectively. The LOD of PRN increased to 400 fmol analyzed in 10% urine, and 200 fmol when analyzed in the brain lipid extract.
Silverio, Angelito A; Chung, Wen-Yaw; Cheng, Cheanyeh; Wang, Hai-Lung; Kung, Chien-Min; Chen, Jun; Tsai, Vincent F S
2016-04-01
It is important to control daily diet, water intake and life style as well as monitor the quality of urine for urolithiasis prevention. For decades, many ion-related indices have been developed for predicting the formation of urinary stones or urolithiasis, such as EQUILs, relative supersaturation (RSS), Tiselius indices (TI), Robertson risk factor algorithms (RRFA) and more recently, the Bonn risk index. However, they mostly demand robust laboratory analysis, are work-intensive, and even require complex computational programs to get the concentration patterns of several urine analytes. A simple and fast platform for measuring multi-frequency electrical conductivity (MFEC) of morning spot urine (random urine) to predict the onset of urolithiasis was implemented in this study. The performance thereof was compared to ion-related indices, urine color and specific gravity. The concentrations of relevant ions, color, specific gravity (SG) and MFEC (MFEC tested at 1, 10, 100, 5001 KHz and 1 MHz) of 80 random urine samples were examined after collection. Then, the urine samples were stored at 4 °C for 24 h to determine whether sedimentation would occur or not. Ion-activity product index of calcium oxalate (AP(CaOx) EQ2) was calculated. The correlation between AP(CaOx) EQ2, urine color, SG and MFEC were analyzed. AP(CaOx) EQ2, urine color and MFEC (at 5 frequencies) all demonstrated good prediction (p = 0.01, 0.01, 0.01, respectively) for stone formation. The positive correlation between AP(CaOx) EQ2 and MFEC is also significant (p = 0.01). MFEC provides a good metric for predicting the onset of urolithiasis, which is comparable to conventional ion-related indices and urine color. This technology can be implemented with much ease for objectively monitoring the quality of urine at points-of-care or at home.
Urine biomarkers in the early stages of diseases: current status and perspective.
Jing, Jian; Gao, Youhe
2018-02-01
As a noninvasive and easily available biological fluid, the urine is becoming an important source for disease biomarker study. Change is essential for the usefulness of a biomarker. Without homeostasis mechanisms, urine can accommodate more changes, especially in the early stages of diseases. In this review, we summarize current status and discuss perspectives on the discovery of urine biomarkers in the early stages of diseases. We emphasize the advantages of urine biomarkers compared to plasma biomarkers for the diagnosis of diseases at early stages, propose a urine biomarker research roadmap, and highlight a novel membrane storage technique that enables large-scale urine sample collection and storage efficiently and economically. It is anticipated that urine biomarker studies will greatly promote early diagnosis, prevention, treatment, and prognosis of a variety of diseases, and provide strong support for translational and precision medicine.
Lech, Teresa
2013-05-01
Exposure to barium (Ba) mostly occurs in the workplace or from drinking water, but it may sometimes be due to accidental or intentional intoxication. This paper presents a reliable, sensitive method for the determination of Ba in blood and urine: inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave digestion of samples. The overall procedure was checked using Seronorm Whole Blood L-2, Trace Elements Urine and spiked blood and urine samples (0.5-10 µg/mL of Ba). The accuracy of the whole procedure (relative error) was 4% (blood) and 7% (urine); the recovery was 76-104% (blood) and 85-101% (urine). The limits of detection and quantification (Ba λ = 455.403 nm) were 0.11 and 0.4 µg/L of Ba, respectively; precision (relative standard deviation) was below 6% at the level of 15 µg/L of Ba for blood. This method was applied to a case of the poisoning of a man who had been exposed at the workplace for over two years to powdered BaCO3, and who suffered from paralysis and heart disorders. The concentrations of Ba, in μg/L, were 160 (blood), 460 (serum) and 1,458 (urine) upon his admission to the hospital, and 6.1 (blood) and 4.9 (urine) after 11 months (reference values: 3.34 ± 2.20 µg/L of Ba for blood and 4.43 ± 4.60 µg/L of Ba for urine).
Voge, Jared; Varner, Dickson D; Blanchard, Terry L; Meschini, Marika; Turner, Carly; Teague, Sheila R; Brinsko, Steven P; Love, Charles C
2016-09-15
Urine-contaminated stallion semen is a clinical problem due to a variety of causes. The effect of the level of urine contamination on the longevity of sperm quality has not been evaluated. The aim of this study was to determine the effects of urine concentration level (0%, 10%, 20%, 30%, and 40%) and cushioned centrifugation and resuspension of the sperm pellet in fresh extender, on measures of sperm quality, immediately after semen collection (T0), after 1 hour of storage at room temperature (T1), and after 24 hours of cooled storage (T24). In general, most sperm quality measures declined with increasing urine concentration starting at T0. Cushioned centrifugation (CC), but not simple dilution, generally maintained sperm quality at T24 as compared with T1. At T24, total sperm motility was higher in all urine-contaminated CC samples compared with uncentrifuged samples (P < 0.05); sperm viability was lower in CC than uncentrifuged at a urine concentration of 20%, but higher at 30% and 40% (P < 0.05); and DNA quality was decreased (higher % cells outside the main population) in all urine concentrations (P < 0.05). Immediate extension in semen extender, followed by cushioned centrifugation and resuspension of the sperm pellet in fresh extender, provided the best option for preserving sperm quality of urospermic semen. Copyright © 2016 Elsevier Inc. All rights reserved.
Agrawal, Kavita; Wu, Hui-Fen
2007-01-01
A simple and rapid method based on drop-to-drop solvent microextraction (DDSME) coupled with gas chromatography/mass spectrometry (GC/MS) has been successfully applied for the pharmacokinetic studies of trimeprazine in 8 microL of urine and blood samples of rats. Several factors that influenced the extraction efficiency of DDSME, such as selection of organic solvent, extraction time, exposure volume of organic phase, addition of salt and pH, were optimized. Linearity was obtained over the concentration ranges of 0.2-10, 0.25-7.0 and 0.5-6.0 microg/mL with correlation coefficients of 0.998, 0.996 and 0.993 in deionized water, urine and blood samples of rats, respectively. The limits of detection (LODs) of trimeprazine were 0.05, 0.06 and 0.1 microg/mL in deionized water, urine and blood samples. The concentrations of trimeprazine obtained in urine and blood samples of rats were 0.21-1.25 and 2.72-0.22 microg/mL, respectively, after a single intravenous administration of this drug. The enrichment factors and LOD values obtained by DDSME coupled to GC/MS were compared with those of hollow fiber liquid-phase microextraction (HF-LPME) combined with GC/MS. We believe that this novel approach can be very useful in clinical application since only one microdrop of biological samples was required to perform the pharmacokinetic studies from rats, so the sample pretreatments for animal experiments can be very easy too. Copyright (c) 2007 John Wiley & Sons, Ltd.
Detection of Genital HPV Infection Using Urine Samples: a Population Based Study in India.
Sabeena, Sasidharanpillai; Bhat, Parvati; Kamath, Veena; Mathew, Mary; Aswathyraj, Sushama; Devadiga, Santhosha; Prabhu, Suresha; Hindol, Maity; Chameetachal, Akhil; Krishnan, Anjana; Arunkumar, Govindakarnavar
2016-01-01
Cervical cancer is the second commonest cancer among Indian women and its association with human papilloma virus (HPV) is well established. This preventable cancer accounts for the maximum number of cancer related deaths among rural Indian women. Unlike in developed countries there are no organized cervical cancer screening programmes in India due to lack of resources and manpower. To detect genital HPV infection using urine samples among asymptomatic rural women in the age group of 18-65 years. The study area chosen was Perdoor village in Udupi Taluk, Karnataka State and all the women in the age group of 18-65 years formed the study cohort. A cross sectional study was conducted by house visits and 1,305 women were enrolled in the study. After taking written informed consent a data sheet was filled and early stream random urine samples were collected, transported to a laboratory at 4OC and aliquoted. Samples were tested using nested HPV PCR with PGMY09/11 and GP5+/6+ primers. Positive cases were genotyped by sequence analysis. Study participants included 1,134 sexually active and 171 unmarried women with a mean age at marriage of 22.1 (SD=3.9) years. Study area showed high female literacy rate of 86.6%. Five urine samples tested positive for HPV DNA (0.4%). We found very low genital HPV infection rate among women from monogamous community. This is the first major population based study carried out among asymptomatic rural women to detect genital HPV infectio from Karnataka using urine samples.
Lou, Chaoyan; Guo, Dandan; Wang, Nani; Wu, Shuchao; Zhang, Peimin; Zhu, Yan
2017-06-02
An online membrane-based distillation (MBD) coupled with ion chromatography (IC) method was proposed for automatic detection of trace fluoride (F - ) in serum and urine samples. The system consisted of a sample vessel, a lab-made membrane module and an ion chromatograph. Hydrophobic polytetrafluoroethylene (PTFE) hollow fiber membrane was used in MBD which was directly performed in serum and urine samples to eliminate the matrix interferences and enrich fluoride, while enabling automation. The determination of fluoride in biological samples was carried out by IC with suppressed conductometric detection. The proposed method feasibly determined trace fluoride in serum and urine matrices with the optimized parameters, such as acid concentration, distillation temperature, and distillation time, etc. Fluoride exhibited satisfactory linearity in the range of 0.01-5.0mg/L with a correlation coefficient of 0.9992. The limit of detection (LOD, S/N=3) and limit of quantification (LOQ, S/N=10) were 0.78μg/L and 2.61μg/L, respectively. The relative standard deviations of peak area and peak height were all less than 5.15%. The developed method was validated for the determination of fluoride in serum and urine with good spiked recoveries ranging between 97.1-101.9%. This method also can be proposed as a suitable alternative for the analysis of fluoride in other complex biological samples. Copyright © 2017. Published by Elsevier B.V.
Bladder cancer biomarker discovery using global metabolomic profiling of urine.
Wittmann, Bryan M; Stirdivant, Steven M; Mitchell, Matthew W; Wulff, Jacob E; McDunn, Jonathan E; Li, Zhen; Dennis-Barrie, Aphrihl; Neri, Bruce P; Milburn, Michael V; Lotan, Yair; Wolfert, Robert L
2014-01-01
Bladder cancer (BCa) is a common malignancy worldwide and has a high probability of recurrence after initial diagnosis and treatment. As a result, recurrent surveillance, primarily involving repeated cystoscopies, is a critical component of post diagnosis patient management. Since cystoscopy is invasive, expensive and a possible deterrent to patient compliance with regular follow-up screening, new non-invasive technologies to aid in the detection of recurrent and/or primary bladder cancer are strongly needed. In this study, mass spectrometry based metabolomics was employed to identify biochemical signatures in human urine that differentiate bladder cancer from non-cancer controls. Over 1000 distinct compounds were measured including 587 named compounds of known chemical identity. Initial biomarker identification was conducted using a 332 subject sample set of retrospective urine samples (cohort 1), which included 66 BCa positive samples. A set of 25 candidate biomarkers was selected based on statistical significance, fold difference and metabolic pathway coverage. The 25 candidate biomarkers were tested against an independent urine sample set (cohort 2) using random forest analysis, with palmitoyl sphingomyelin, lactate, adenosine and succinate providing the strongest predictive power for differentiating cohort 2 cancer from non-cancer urines. Cohort 2 metabolite profiling revealed additional metabolites, including arachidonate, that were higher in cohort 2 cancer vs. non-cancer controls, but were below quantitation limits in the cohort 1 profiling. Metabolites related to lipid metabolism may be especially interesting biomarkers. The results suggest that urine metabolites may provide a much needed non-invasive adjunct diagnostic to cystoscopy for detection of bladder cancer and recurrent disease management.
Cross-Reactivity of Pantoprazole with Three Commercial Cannabinoids Immunoassays in Urine.
Gomila, Isabel; Barceló, Bernardino; Rosell, Antonio; Avella, Sonia; Sahuquillo, Laura; Dastis, Macarena
2017-11-01
Pantoprazole is a frequently prescribed proton pump inhibitor (PPI) commonly utilized in the management of gastrointestinal symptoms. Few substances have proved to cause a false-positive cannabinoid urine screen. However, a case of false-positive urine cannabinoid screen in a patient who received a pantoprazole dose has been recently published. The purpose of this study was to determine the potential cross-reactivity of pantoprazole in the cannabinoid immunoassays: Alere Triage® TOX Drug Screen, KIMS® Cannabinoids II and DRI® Cannabinoids Assay. Drug-free urine to which pantoprazole was added up to 12,000 μg/mL produced negative results in the DRI® Cannabinoids and KIMS® Cannabinoids II. Alere Triage® TOX Drug Screen assay gave positive results at pantoprazole concentrations higher than 1,000 μg/mL. Urine samples from 8 pediatric patients were collected at the beginning of their pantoprazole treatment. Alere Triage® TOX Drug Screen assay produced positive test results in all patient samples and KIMS® Cannabinoids II immunoassay produced positive test results in one patient sample. None patient sample gave a false-positive result when analyzed by the DRI® Cannabinoids Assay. Our findings demonstrate that some cannabinoids immunoassays are susceptible to cross-reaction errors resulting from the presence in urine of pantoprazole and the resulting metabolism of the parent drug. Clinicians should be aware of the possibility of false-positive results for cannabinoids after a pantoprazole treatment. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Nixon, David E.; Neubauer, Kenneth R.; Eckdahl, Steven J.; Butz, John A.; Burritt, Mary F.
2003-01-01
A Dynamic Reaction Cell™ inductively coupled plasma mass spectrometer (DRC-ICP-MS) was evaluated for the determination of selenium in serum and urine. Reaction cell conditions were evaluated for the suppression of Ar 2+ dimer at m/ z 78 and 80 using methane as the reaction gas. A diluent containing 10% ethanol, 1% nitric acid, 0.5% Triton X-100 with gallium and yttrium internal standards was used to dilute urine and serum samples. Instrument response calibration was achieved by using aqueous acidic standards spiked into a urine matrix. Slopes for aqueous inorganic selenium, seleno- DL-cystine, seleno- DL-methionine and trimethylselenonium iodide spiked into urine and serum matrices were nearly identical. In general, reagent blank readings and detection limits were significantly lower in the DRC mode (reaction cell pressurized) than the standard mode (cell vented). Average results for the analysis of National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1598 bovine serum (attained over 13 days) are: 43.8±3.6 μg Se/l. Reference concentration is 43.6±3.6 μg Se/l. For NIST SRM 2670 Normal Urine the DRC-ICP-MS results are 30.7±4.6 μg Se/l with a certified concentration of 30±8 μg Se/l. For NIST SRM 2670 Elevated Urine the DRC-ICP-MS results are 463±35 μg Se/l with a certified concentration of 460±30 μg Se/l. The DRC-ICP-MS results for selenium determinations in urine and serum survey samples from the Institut National de Sante Publique du Quebec were compared with the reference concentrations and results produced by conventional ICP-MS. While conventional ICP-MS gave acceptable results for survey samples, DRC-ICP-MS gave excellent results for both urine and sera. Closer correlation was observed for DRC-ICP-MS results with target concentrations than with conventional ICP-MS.
Hay, Alastair D.; Sterne, Jonathan A. C.; Hood, Kerenza; Little, Paul; Delaney, Brendan; Hollingworth, William; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Lawton, Michael; Busby, John; Pickles, Timothy; Birnie, Kate; O’Brien, Kathryn; Waldron, Cherry-Ann; Dudley, Jan; Van Der Voort, Judith; Downing, Harriet; Thomas-Jones, Emma; Harman, Kim; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Butler, Christopher C.
2016-01-01
PURPOSE Up to 50% of urinary tract infections (UTIs) in young children are missed in primary care. Urine culture is essential for diagnosis, but urine collection is often difficult. Our aim was to derive and internally validate a 2-step clinical rule using (1) symptoms and signs to select children for urine collection; and (2) symptoms, signs, and dipstick testing to guide antibiotic treatment. METHODS We recruited acutely unwell children aged under 5 years from 233 primary care sites across England and Wales. Index tests were parent-reported symptoms, clinician-reported signs, urine dipstick results, and clinician opinion of UTI likelihood (clinical diagnosis before dipstick and culture). The reference standard was microbiologically confirmed UTI cultured from a clean-catch urine sample. We calculated sensitivity, specificity, and area under the receiver operator characteristic (AUROC) curve of coefficient-based (graded severity) and points-based (dichotomized) symptom/sign logistic regression models, and we then internally validated the AUROC using bootstrapping. RESULTS Three thousand thirty-six children provided urine samples, and culture results were available for 2,740 (90%). Of these results, 60 (2.2%) were positive: the clinical diagnosis was 46.6% sensitive, with an AUROC of 0.77. Previous UTI, increasing pain/crying on passing urine, increasingly smelly urine, absence of severe cough, increasing clinician impression of severe illness, abdominal tenderness on examination, and normal findings on ear examination were associated with UTI. The validated coefficient- and points-based model AUROCs were 0.87 and 0.86, respectively, increasing to 0.90 and 0.90, respectively, by adding dipstick nitrites, leukocytes, and blood. CONCLUSIONS A clinical rule based on symptoms and signs is superior to clinician diagnosis and performs well for identifying young children for noninvasive urine sampling. Dipstick results add further diagnostic value for empiric antibiotic treatment. PMID:27401420
Vera, Pedro L; Preston, David M; Moldwin, Robert M; Erickson, Deborah R; Mowlazadeh, Behzad; Ma, Fei; Kouzoukas, Dimitrios E; Meyer-Siegler, Katherine L; Fall, Magnus
2018-06-01
To investigate whether urinary levels of macrophage migration inhibitory factor (MIF) are elevated in interstitial cystitis/bladder pain syndrome (IC/BPS) patients with Hunner lesions and also whether urine MIF is elevated in other forms of inflammatory cystitis. Urine samples were assayed for MIF by enzyme-linked immunosorbent assay. Urine samples from 3 female groups were examined: IC/BPS patients without (N = 55) and with Hunner lesions (N = 43), and non-IC/BPS patients (N = 100; control group; no history of IC/BPS; cancer or recent bacterial cystitis). Urine samples from 3 male groups were examined: patients with bacterial cystitis (N = 50), radiation cystitis (N = 18) and noncystitis patients (N = 119; control group; negative for bacterial cystitis). Urine MIF (mean MIF pg/mL ± standard error of the mean) was increased in female IC/BPS patients with Hunner lesions (2159 ± 435.3) compared with IC/BPS patients without Hunner lesions (460 ± 114.5) or non-IC/BPS patients (414 ± 47.6). Receiver operating curve analyses showed that urine MIF levels discriminated between the 2 IC groups (area under the curve = 72%; confidence interval 61%-82%). Male patients with bacterial and radiation cystitis had elevated urine MIF levels (2839 ± 757.1 and 4404 ± 1548.1, respectively) compared with noncystitis patients (681 ± 75.2). Urine MIF is elevated in IC/BPS patients with Hunner lesions and also in patients with other bladder inflammatory and painful conditions. MIF may also serve as a noninvasive biomarker to select IC/BPS patients more accurately for endoscopic evaluation and possible anti-inflammatory treatment. Copyright © 2018 Elsevier Inc. All rights reserved.
Hay, Alastair D; Sterne, Jonathan A C; Hood, Kerenza; Little, Paul; Delaney, Brendan; Hollingworth, William; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Lawton, Michael; Busby, John; Pickles, Timothy; Birnie, Kate; O'Brien, Kathryn; Waldron, Cherry-Ann; Dudley, Jan; Van Der Voort, Judith; Downing, Harriet; Thomas-Jones, Emma; Harman, Kim; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Butler, Christopher C
2016-07-01
Up to 50% of urinary tract infections (UTIs) in young children are missed in primary care. Urine culture is essential for diagnosis, but urine collection is often difficult. Our aim was to derive and internally validate a 2-step clinical rule using (1) symptoms and signs to select children for urine collection; and (2) symptoms, signs, and dipstick testing to guide antibiotic treatment. We recruited acutely unwell children aged under 5 years from 233 primary care sites across England and Wales. Index tests were parent-reported symptoms, clinician-reported signs, urine dipstick results, and clinician opinion of UTI likelihood (clinical diagnosis before dipstick and culture). The reference standard was microbiologically confirmed UTI cultured from a clean-catch urine sample. We calculated sensitivity, specificity, and area under the receiver operator characteristic (AUROC) curve of coefficient-based (graded severity) and points-based (dichotomized) symptom/sign logistic regression models, and we then internally validated the AUROC using bootstrapping. Three thousand thirty-six children provided urine samples, and culture results were available for 2,740 (90%). Of these results, 60 (2.2%) were positive: the clinical diagnosis was 46.6% sensitive, with an AUROC of 0.77. Previous UTI, increasing pain/crying on passing urine, increasingly smelly urine, absence of severe cough, increasing clinician impression of severe illness, abdominal tenderness on examination, and normal findings on ear examination were associated with UTI. The validated coefficient- and points-based model AUROCs were 0.87 and 0.86, respectively, increasing to 0.90 and 0.90, respectively, by adding dipstick nitrites, leukocytes, and blood. A clinical rule based on symptoms and signs is superior to clinician diagnosis and performs well for identifying young children for noninvasive urine sampling. Dipstick results add further diagnostic value for empiric antibiotic treatment. © 2016 Annals of Family Medicine, Inc.
Determination of actinides in urine and fecal samples
McKibbin, Terry T.
1993-01-01
A method of determining the radioactivity of specific actinides that are carried in urine or fecal sample material is disclosed. The samples are ashed in a muffle furnace, dissolved in an acid, and then treated in a series of steps of reduction, oxidation, dissolution, and precipitation, including a unique step of passing a solution through a chloride form anion exchange resin for separation of uranium and plutonium from americium.
Determination of actinides in urine and fecal samples
McKibbin, T.T.
1993-03-02
A method of determining the radioactivity of specific actinides that are carried in urine or fecal sample material is disclosed. The samples are ashed in a muffle furnace, dissolved in an acid, and then treated in a series of steps of reduction, oxidation, dissolution, and precipitation, including a unique step of passing a solution through a chloride form anion exchange resin for separation of uranium and plutonium from americium.
Ortiz, M C; Sarabia, L A; Sánchez, M S; Giménez, D
2009-05-29
Due to the second-order advantage, calibration models based on parallel factor analysis (PARAFAC) decomposition of three-way data are becoming important in routine analysis. This work studies the possibility of fitting PARAFAC models with excitation-emission fluorescence data for the determination of ciprofloxacin in human urine. The finally chosen PARAFAC decomposition is built with calibration samples spiked with ciprofloxacin, and with other series of urine samples that were also spiked. One of the series of samples has also another drug because the patient was taking mesalazine. The mesalazine is a fluorescent substance that interferes with the ciprofloxacin. Finally, the procedure is applied to samples of a patient who was being treated with ciprofloxacin. The trueness has been established by the regression "predicted concentration versus added concentration". The recovery factor is 88.3% for ciprofloxacin in urine, and the mean of the absolute value of the relative errors is 4.2% for 46 test samples. The multivariate sensitivity of the fit calibration model is evaluated by a regression between the loadings of PARAFAC linked to ciprofloxacin versus the true concentration in spiked samples. The multivariate capability of discrimination is near 8 microg L(-1) when the probabilities of false non-compliance and false compliance are fixed at 5%.
Nontargeted analysis of the urine nonpolar sulfateome: a pathway to the nonpolar xenobiotic exposome
Yao, Yuanyuan; Wang, Poguang; Shao, Gang; Anzalota Del Toro, Liza V.; Codero, Jose; Giese, Roger W.
2016-01-01
RATIONALE Testing the urine nonpolar sulfateome can enable discovery of xenobiotics that are most likely to be bioactive. This is based on the fact that nonpolar xenobiotics are more likely to enter cells where they tend to undergo metabolism, in part, to sulfates that are then largely excreted into the urine. METHODS The following sequence of steps, with conditions that achieve high reproducibility, was applied to large human urine samples: (1) competitive nonpolar extraction with a porous extraction paddle; (2) weak anion exchange extraction with strong organic washing; and (3) UHPLC/negative ion-MALDI-TOF/TOF-MS with recording of ions with S/N ≥ 20 that yielded M-1-80 (loss of SO3) or m/z 97 (HSO4−) upon fragmentation. RESULTS From a collection of urine samples from six pregnant women, the masses of 1129 putative sulfates were measured. Three lists of candidate compounds (preliminary hits) from these masses were formed by searching METLIN, especially via MATLAB, yielding putative xenobiotic contaminants (35 compounds), steroids (122), and flavonoids (1582). CONCLUSION A new way to reveal some of the nonpolar xenobiotic exposome has been developed that applies to urine samples. The value of the method is to suggest xenobiotics for subsequent targeted analysis in the population of people under study, in order to relate the environment to health and disease. PMID:27557133
Cui, Meng; McCooeye, Margaret A; Fraser, Catharine; Mester, Zoltán
2004-12-01
A quantitative method was developed for analysis of lysergic acid diethylamide (LSD) in urine using atmospheric pressure matrix-assisted laser desorption/ionization ion trap mass spectrometry (AP MALDI-ITMS). Following solid-phase extraction of LSD from urine samples, extracts were analyzed by AP MALDI-ITMS. The identity of LSD was confirmed by fragmentation of the [M + H](+) ion using tandem mass spectrometry. The quantification of LSD was achieved using stable-isotope-labeled LSD (LSD-d(3)) as the internal standard. The [M + H](+) ion fragmented to produce a dominant fragment ion, which was used for a selected reaction monitoring (SRM) method for quantitative analysis of LSD. SRM was compared with selected ion monitoring and produced a wider linear range and lower limit of quantification. For SRM analysis of samples of LSD spiked in urine, the calibration curve was linear in the range of 1-100 ng/mL with a coefficient of determination, r(2), of 0.9917. This assay was used to determine LSD in urine samples and the AP MALDI-MS results were comparable to the HPLC/ ESI-MS results.
Hashemian, Zahra; Khayamian, Taghi; Saraji, Mohammad
2015-02-01
A combination of thin-film microextaction based on an aptamer immobilized on modified Whatman cellulose paper followed by electrospray ionization ion mobility spectrometry has been developed for the analysis of codeine in urine samples. The immobilization is based on the covalent linking of an amino-modified anticodeine aptamer to aldehyde groups of the oxidized cellulose paper. The covalent bonds were examined by infrared spectroscopy and elemental analysis. The effect of the extraction parameters, including the elution conditions (solvent type and volume), extraction time, and extraction temperature, on the extraction efficiency were investigated. Under the optimized conditions, the linear dynamic range was found to be 10-300 ng/mL with a detection limit of 3.4 ng/mL for codeine in urine. The relative standard deviation was 6.8% for three replicate measurements of codeine at 100 ng/mL in urine. Furthermore, the samples were analyzed with a standard method for the analysis of codeine using high-performance liquid chromatography with ultraviolet detection. The comparison of the results validates the accuracy of the proposed method as an alternative method for the analysis of codeine in urine samples.
Detection of Ciprofloxacin in Urine through Sensitized Lanthanide Luminescence
Singha, Subhankar; Ahn, Kyo Han
2016-01-01
Ciprofloxacin, a fluoroquinolone antibiotic, is widely used for the treatment of bacterial infection in humans due to its broad antibacterial spectrum. An excessive use or overdose of ciprofloxacin on the other hand can cause several adverse effects not only to humans but also to microorganisms. Unabsorbed ciprofloxacin in the body is mostly excreted through urine and finally goes to the environment, providing a drug resistance pressure on bacteria. Hence a simple and efficient detection method of ciprofloxacin is necessary, which, for example, can be used to analyze ciprofloxacin content in urine. Although ciprofloxacin itself shows inherent fluorescence, direct fluorescent detection of ciprofloxacin in raw urine sample is difficult due to autofluorescence of urine by other components. Herein we report that a Tb(III) complex of DO3A (1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid) can be efficiently sensitized by ciprofloxacin to emit luminescence separately from the urine autofluorescence wavelength region. Tb-DO3A shows excellent sensitivity with a detection limit of three parts per billion in aqueous buffer solution. Further, Tb-DO3A is used to detect ciprofloxacin with high sensitivity and selectivity in a raw urine sample without any purification or separation procedures in the concentrations ranging from 1 µg·mL−1 to 50 µg·mL−1. The direct measurement of ciprofloxacin excreted in urine may be used to control overdose of the drug. PMID:27929396
Nameta, Masaaki; Saijo, Yoko; Ohmoto, Yasukazu; Katsuragi, Kiyonori; Yamamoto, Keiko; Yamamoto, Tadashi; Ishibashi, Kenichi; Sasaki, Sei
2016-01-01
Aquaporin-2 (AQP2) is present in urine extracellular vesicles (EVs) and is a useful biomarker for water balance disorders. We previously found that pre-treatment of urine with alkali/detergent or storage at −25 °C is required for enzyme-linked immunosorbent assay (ELISA) measurement. We speculated that disruptions of EVs membranes are necessary to allow for the direct contact of antibodies with their epitopes. Human urine EVs were prepared using an ultracentrifugation method. Urine EV samples were stored at different temperatures for a week. Electron microscopy showed abundant EVs with diameters of 20–100 nm, consistent with those of exosomes, in normal urine, whereas samples from alkali/detergent pre-treated urine showed fewer EVs with large swollen shapes and frequent membrane disruptions. The abundance and structures of EVs were maintained during storage at −80 °C, but were severely damaged at −25 °C. Binding and competitive inhibition assays showed that epitopes of monoclonal antibody and polyclonal antibody were the hydrophilic Loop D and C-terminus of AQP2, respectively, both of which are present on the inner surface of EVs. Thus, urine storage at −25 °C or pre-treatment with alkali/detergent disrupt EVs membranes and allow AQP2 antibodies to bind to their epitopes located inside EVs. PMID:27681727
Wang, H; Zhao, L; Xi, Y; Sun, N
2015-06-01
24-h urine sodium excretion is considered the most reliable method to evaluate the salt intakes. However, this method is cumbersome. So we want to develop formulas to estimate 24-h urinary sodium excretion using spot urinary samples in Chinese hypertensive population and explore the application value of this method in salt intake assessment and target organ damage. 1. We enrolled 510 cases of hospitalized patients with hypertension, 2/3 of them were arranged randomly to formula group to develop a new formula and the remainings were used to test the performance of the formula. All participants were instructed to collect a 24-h urine sample, a second morning voiding urine sample (SMU), and a post-meridiem urine sample in the late afternoon or early evening, prior to the evening meal (PMU). All samples were sent to measure sodium and creatinine concentration.2. We compared the differences of office blood pressure, 24-hour ambulatory blood pressure and left ventricular hypertrophy, vascular stiffness and urine protein among groups of different sodium intake. 24hour sodium excretion formulas was obtained using SMU and PMU respectively, which have good cosistency. The difference between the estimated and measured values in sodium excretion is 12.66mmol/day (SMU) and 9.41mmol/day (PM), to be equal to 0.7 g (SMU) and 0.6 g (PM) salt intake. Comparing with Kawasaki and Tanaka method, the new formula shows the lower degree of deviation, and higher accuracy and precision. Blood pressure of high urinary sodium group is higher than that in low urinary sodium group (P < 0.05). Left ventricular hypertrophy and urinary albumin/creatinine aggravated with the salt intake increase, this has eliminated the influence of other factors. All of morphologies of the relationship between ambulatory arterial stiffness index, pulse wave velocity and carotid intima-media thickness with quartiles of sodium intake resembled a J-shaped curve. In Chinese hypertensive population, the formulas to estimate 24-h urinary sodium using spot urinary samples spot urine are considered useful for estimating the mean level of population salt intake, and have a role in evaluating target organ damage.
Agius, Ronald; Nadulski, Thomas
2014-06-01
Amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in authentic hair samples with drug concentrations around the medical and psychological assessment (MPA) guidelines cut-offs were screened by LUCIO-direct ELISA kits. Following confirmation of all positive and a significant number of negatively screened samples with gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods accredited for forensic purposes. Receiver operating characteristics (ROC) were plotted and the area under the curve (AUC) and overall misclassification rate (OMR) were calculated and compared to those obtained for the same drug classes in urine. While fulfilling the validation criteria of the German forensic guidelines, for almost all screening tests in hair and urine the AUC were greater than 0.8, indicating good to excellent performance. Moreover the AUC calculated for the detection of drugs in hair did not differ significantly to the AUC calculated for the detection of the same drug classes in urine, thus showing a comparable screening performance to the well accepted, previously published application of the same ELISAs for the detection of drugs at unconventionally low cut-offs in urine. For the first time, the validation of the immunoassay tests for the complete 6-drug panel MPA profile in hair and urine using a large population of authentic hair and urine samples with drug concentrations around MPA cut-offs, lower than conventional clinical or workplace drug testing guidelines cut-offs as well as those suggested by the Society of hair testing (SoHT) is presented. Copyright © 2014 John Wiley & Sons, Ltd.
Natural calcium isotonic composition of urine as a marker of bone mineral balance
Skulan, J.; Bullen, T.; Anbar, A.D.; Puzas, J.E.; Shackelford, L.; LeBlanc, A.; Smith, S.M.
2007-01-01
Background: We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Methods: Calcium isotopic compositions are expressed as ??44Ca, or the difference in parts per thousand between the 44Ca/40Ca of a sample and the 44Ca/ 40Ca of a standard reference material. ??44Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Results: Urine ??44Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, Mest). Results were consistent with the model and with biochemical and bone mineral density data. Conclusion: Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool. ?? 2007 American Association for Clinical Chemistry.
Chericoni, S; Stefanelli, F; Iannella, V; Giusiani, M
2014-02-15
Opiates play a relevant role in forensic toxicology and their assay in urine or blood is usually performed for example in workplace drug-testing or toxicological investigation of drug impaired driving. The present work describes two new methods for detecting morphine, codeine and 6-monoacethyl morphine in human urine or blood using a single step derivatisation in aqueous phase. Propyl chloroformate is used as the dramatizing agent followed by liquid-liquid extraction and gas-chromatography-mass spectroscopy to detect the derivatives. The methods have been validated both for hydrolysed and unhydrolysed urine. For hydrolysed urine, the LOD and LOQ were 2.5ng/ml and 8.5ng/ml for codeine, and 5.2ng/ml and 15.1ng/ml for morphine, respectively. For unhydrolysed urine, the LOD and LOQ were 3.0ng/ml and 10.1ng/ml for codeine, 2.7ng/ml and 8.1ng/ml for morphine, 0.8ng/ml and 1.5ng/ml for 6-monoacetyl morphine, respectively. In blood, the LOD and LOQ were 0.44ng/ml and 1.46ng/ml for codeine, 0.29ng/ml and 0.98ng/ml for morphine, 0.15ng/ml and 0.51ng/ml for 6-monoacetyl morphine, respectively. The validated methods have been applied to 50 urine samples and 40 blood samples (both positive and negative) and they can be used in routine analyses. Copyright © 2013 Elsevier B.V. All rights reserved.
Wang, Xijun; Lv, Haitao; Zhang, Guangmei; Sun, Wenjun; Zhou, Dixin; Jiao, Guozheng; Yu, Yang
2008-09-01
Ultra-performance LC coupled to quadrupole TOF/MS (UPLC-QTOF/MS) in positive and negative ESI was developed and validated to analyze metabolite profiles for urine from healthy men during the day and at night. Data analysis using principal components analysis (PCA) revealed differences between metabolic phenotypes of urine in healthy men during the day and at night. Positive ions with mass-to-charge ratio (m/z) 310.24 (5.35 min), 286.24 (4.74 min) and 310.24 (5.63 min) were elevated in the urine from healthy men at night compared to that during the day. Negative ions elevated in day urine samples of healthy men included m/z 167.02 (0.66 min), 263.12 (2.55 min) and 191.03 (0.73 min), whilst ions m/z 212.01 (4.77 min) were at a lower concentration in urine of healthy men during the day compared to that at night. The ions m/z 212.01 (4.77 min), 191.03 (0.73 min) and 310.24 (5.35 min) preliminarily correspond to indoxyl sulfate, citric acid and N-acetylneuraminic acid, providing further support for an involvement of phenotypic difference in urine of healthy men in day and night samples, which may be associated with notably different activities of gut microbiota, velocity of tricarboxylic acid cycle and activity of sialic acid biosynthesis in healthy men as regulated by circadian rhythm of the mammalian bioclock.
Marcos, Josep; Ibañez, Maria; Ventura, Rosa; Segura, Jordi; To-Figueras, Jordi; Pozo, Oscar J
2015-07-01
We document the presence of a previously unknown species in the urine of patients with acute intermittent porphyria (AIP). The compound was fully characterised by liquid chromatography tandem mass spectrometry. Interpretation of both full spectrum acquisition and product ion spectra acquired in positive and negative ionisation modes by quadrupole time of flight MS allowed for the identification of a condensation product arising from porphobilinogen (PBG, increased in the urine of AIP patients) and indolyl-3-acryloylglycine (IAG, derived from indolylacrylic acid and present in human urine). The structure was unequivocally confirmed through comparison between the selected reaction monitoring chromatograms obtained from the urinary species and the condensation product qualitatively synthesised in the laboratory. Owing to the large amounts of both PBG and IAG in urine of AIP patients, the possible ex vivo formation of PBG-IAG in urine samples was evaluated. The product was spontaneously formed at room temperature, at 4 °C and even during storage at -20 °C when spiking a control sample with PBG. A positive correlation was found between PBG and PBG-IAG in samples collected from AIP patients. However, no correlation was found between PBG-IAG and IAG. Purified PBG-IAG did not form the characteristic chromogen after application of p-dimethylaminobenzaldehyde in HCl, thus suggesting that the current techniques used to measure PBG in urine of AIP patients based on Ehlrich's reaction do not detect this newly characterised PBG-IAG fraction. Copyright © 2015 John Wiley & Sons, Ltd.
Natural calcium isotopic composition of urine as a marker of bone mineral balance.
Skulan, Joseph; Bullen, Thomas; Anbar, Ariel D; Puzas, J Edward; Shackelford, Linda; LeBlanc, Adrian; Smith, Scott M
2007-06-01
We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Calcium isotopic compositions are expressed as delta(44)Ca, or the difference in parts per thousand between the (44)Ca/(40)Ca of a sample and the (44)Ca/(40)Ca of a standard reference material. delta(44)Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Urine delta(44)Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, t-test). Results were consistent with the model and with biochemical and bone mineral density data. Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool.
Organisational Capability in Internalising Quality Culture in Higher Institution
ERIC Educational Resources Information Center
Bello, Muhammad Ibrahim; Ibrahim, Burhan Muhammad Bn; Bularafa, Mohammed Waziri
2015-01-01
The study examines the influence of leadership roles related to organisational capability consisting of directing setting, strategic and organisational process, alignment, intervention and strategic capability on depending variable internalising quality culture in IIUM. The study used 100 samples consisting of lecturers, non-academic staff and…
High throughput-screening of animal urine samples: It is fast but is it also reliable?
Kaufmann, Anton
2016-05-01
Advanced analytical technologies like ultra-high-performance liquid chromatography coupled to high resolution mass spectrometry can be used for veterinary drug screening of animal urine. The technique is sufficiently robust and reliable to detect veterinary drugs in urine samples of animals where the maximum residue limit of these compounds in organs like muscle, kidney, or liver has been exceeded. The limitations and possibilities of the technique are discussed. The most critical point is the variability of the drug concentration ratio between the tissue and urine. Ways to manage the false positive and false negatives are discussed. The capability to confirm findings and the possibility of semi-targeted analysis are also addressed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Detection of illicit drugs in urine in the Division of Neonatology, Hospital Molas in La Pampa.
Villarreal, Marina; Ré, Silvina
2013-06-01
There are few studies on the use of illicit drugs during pregnancy with a variable prevalence depending on the year, maternal age, region and diagnostic methods. Mothers' and newborn infants' urine samples were tested for illegal drugs in cases where the mother reported consumption, lack of antenatal care and neonatal signs and symptoms, from 2009 to 2011. A rapid strip test for simultaneous qualitative detection of multiple drugs and metabolites in urine was used. In 19 out of 39 (49%) cases in which urine samples were collected, an illicit drug was detected in the mother and/or the newborn infant. Cocaine was the most frequently detected drug. There was a high coexistence of social and familiar risk factors, smoking (84%) and alcohol consumption (47%).
Urinary Virome Perturbations in Kidney Transplantation.
Sigdel, Tara K; Mercer, Neil; Nandoe, Sharvin; Nicora, Carrie D; Burnum-Johnson, Kristin; Qian, Wei-Jun; Sarwal, Minnie M
2018-01-01
The human microbiome is important for health and plays a role in essential metabolic functions and protection from certain pathogens. Conversely, dysbiosis of the microbiome is seen in the context of various diseases. Recent studies have highlighted that a complex microbial community containing hundreds of bacteria colonizes the healthy urinary tract, but little is known about the human urinary viruses in health and disease. To evaluate the human urinary virome in the context of kidney transplantation (tx), variations in the composition of the urinary virome were evaluated in urine samples from normal healthy volunteers as well as patients with kidney disease after they had undergone kidney tx. Liquid chromatography-mass spectrometry/mass spectrometry analysis was undertaken on a selected cohort of 142 kidney tx patients and normal healthy controls, from a larger biobank of 770 kidney biopsy matched urine samples. In addition to analysis of normal healthy control urine, the cohort of kidney tx patients had biopsy confirmed phenotype classification, coincident with the urine sample analyzed, of stable grafts (STA), acute rejection, BK virus nephritis, and chronic allograft nephropathy. We identified 37 unique viruses, 29 of which are being identified for the first time in human urine samples. The composition of the human urinary virome differs in health and kidney injury, and the distribution of viral proteins in the urinary tract may be further impacted by IS exposure, diet and environmental, dietary, or cutaneous exposure to various insecticides and pesticides.
HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries.
Frati, Elena Rosanna; Martinelli, Marianna; Fasoli, Ester; Colzani, Daniela; Bianchi, Silvia; Binda, Sandro; Olivani, Pierfranco; Tanzi, Elisabetta
2015-01-01
Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV) testing from dried urine spots (DUS). Eighty-eight urine samples (including 56 HPV DNA positive specimens) were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR) assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56-99.68) for DUS stored for 1 week and 96.42% (95% CI: 87.88-99.01) for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28-100) at both time points. The concordance between DUS and fresh urine HPV testing was "almost perfect" using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries.
Effect of storage temperature on endogenous GHB levels in urine.
LeBeau, M A; Miller, M L; Levine, B
2001-06-15
Because gamma-hydroxybutyrate (GHB) is an endogenous substance present in the body and is rapidly eliminated after ingestion, toxicologists investigating drug-facilitated sexual assault cases are often asked to differentiate between endogenous and exogenous levels of GHB in urine samples. This study was designed to determine the effects of storage temperature on endogenous GHB levels in urine. Specifically, it was designed to ascertain whether endogenous levels can be elevated to a range considered indicative of GHB ingestion. Urine specimens from two subjects that had not been administered exogenous GHB were collected during a 24h period and individually pooled. The pooled specimens were separated into standard sample cups and divided into three storage groups: room temperature ( approximately 25 degrees C), refrigerated (5 degrees C), and frozen (-10 degrees C). Additionally, some specimens were put through numerous freeze/thaw cycles to mimic situations that may occur if multiple laboratories analyze the same specimen. Periodic analysis of the samples revealed increases in the levels of endogenous GHB over a 6-month period. The greatest increase (up to 404%) was observed in the samples maintained at room temperature. The refrigerated specimens showed increases of 140-208%, while the frozen specimens showed smaller changes (88-116%). The specimens subjected to multiple freeze/thaw cycles mirrored specimens that had been thawed only once. None of the stored urine specimens demonstrated increases in GHB concentrations that would be consistent with exogenous GHB ingestion.
Huisman, Han; Wynveen, Paul; Nichkova, Mikaela; Kellermann, Gottfried
2010-08-01
The inhibitory neurotransmitters GABA, glycine and agmatine and neuromodulators beta-phenylethylamine (beta-PEA) and taurine are important biogenic amines of the sympathetic and parasympathetic nervous systems in the body. Abnormalities in the metabolism of these biomarkers have been implicated in a vast number of neurological diseases. Novel competitive immunoassays, using one unique whole urine derivatization procedure applicable for all five biomarkers, have been developed. The determination of these biomarkers was highly reproducible: the coefficient of variance of inter- and intra-assay variation is between 3.9% and 9.8% for all assays. The assays show a good linearity in urine samples within the range of 100-400 mg Cr/dL and specificity when urine samples are spiked with biogenic amines. The recoveries are between 76 and 154%. The correlation between HPLC and ELISA for glycine and taurine (n = 10) showed regression coefficients of 0.97 and 0.98, respectively. An in vivo study on the urinary clearance of beta-PEA, agmatine and taurine after oral intake by healthy individuals demonstrated the specificity and clinical significance of these new immunoassays. The immunoassays are useful for clinical and basic research where a fast and accurate assay for the screening of biogenic amines in urine is required, without preclearance of the sample.
Evaluation of a nested-PCR for mycobacterium tuberculosis detection in blood and urine samples.
da Cruz, Heidi Lacerda Alves; de Albuquerque Montenegro, Rosana; de Araújo Lima, Juliana Falcão; da Rocha Poroca, Diogo; da Costa Lima, Juliana Figueirêdo; Maria Lapa Montenegro, Lílian; Crovella, Sergio; Charifker Schindler, Haiana
2011-01-01
The polymerase chain reaction (PCR) and its variations, such as the nested-PCR, have been described as promising techniques for rapid diagnosis of tuberculosis (TB). With the aim of evaluating the usefulness of a nested-PCR method on samples of blood and urine of patients suspected of tuberculosis we analyzed 192 clinical samples, using as a molecular target the insertion element IS6110 specific of M. tuberculosis genome. Nested-PCR method showed higher sensitivity in patients with extrapulmonary tuberculosis (47.8% and 52% in blood and urine) when compared to patients with the pulmonary form of the disease (sensitivity of 29% and 26.9% in blood and urine), regardless of the type of biological sample used. The nested-PCR is a rapid technique that, even if not showing a good sensitivity, should be considered as a helpful tool especially in the extrapulmonary cases or in cases where confirmatory diagnosis is quite difficult to be achieved by routine methods. The performance of PCR-based techniques should be considered and tested in future works on other types of biological specimens besides sputum, like blood and urine, readily obtainable in most cases. The improving of M. tuberculosis nested-PCR detection in TB affected patients will give the possibility of an earlier detection of bacilli thus interrupting the transmission chain of the disease.
HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries
Olivani, Pierfranco
2015-01-01
Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV) testing from dried urine spots (DUS). Eighty-eight urine samples (including 56 HPV DNA positive specimens) were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR) assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56–99.68) for DUS stored for 1 week and 96.42% (95% CI: 87.88–99.01) for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28–100) at both time points. The concordance between DUS and fresh urine HPV testing was “almost perfect” using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries. PMID:26180790
Wang, Xiaoming; Rytting, Erik; Abdelrahman, Doaa R.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.
2013-01-01
The liquid chromatography with electrospray ionization mass spectrometry for the quantitative determination of famotidine in human urine, maternal and umbilical cord plasma was developed and validated. The plasma samples were alkalized with ammonium hydroxide and extracted twice with ethyl acetate. The extraction recovery of famotidine in maternal and umbilical cord plasma ranged from 53% to 64% and 72% to 79%, respectively. Urine samples were directly diluted with the initial mobile phase then injected into the HPLC system. Chromatographic separation of famotidine was achieved by using a Phenomenex Synergi™ Hydro-RP™ column with a gradient elution of acetonitrile and 10 mM ammonium acetate aqueous solution (pH 8.3, adjusted with ammonium hydroxide). Mass Spectrometric detection of famotidine was set in the positive mode and used a selected ion monitoring method. Carbon-13-labeled famotidine was used as internal standard. The calibration curves were linear (r2> 0.99) in the concentration ranges of 0.631-252 ng/mL for umbilical and maternal plasma samples, and of 0.075-30.0 μg/mL for urine samples. The relative deviation of method was less than 14% for intra- and inter-day assays, and the accuracy ranged between 93% and 110%. The matrix effect of famotidine in human urine, maternal and umbilical cord plasma is less than 17%. PMID:23401067
Nikolelis, Dimitrios P; Drivelos, Dimitrios A; Simantiraki, Maria G; Koinis, Spyros
2004-04-15
The present technique describes a simple, sensitive spot test for the rapid one-shot detection of dopamine in human urine using lipid films with incorporated resorcin[4]arene receptor that are synthesized by a chemical reaction with a methacrylate polymer on a glass fiber filter. The lipid films without the receptor provided fluorescence under a UV lamp. The use of the receptor in these films quenched this fluorescence, and the color became similar to that of the filters without the lipid films. A drop of dopamine or urine containing this stimulant provided a "switching on" of the fluorescence, which allows the rapid detection of this stimulant in human urine at 10(-8) M concentrations. The novelty of the present work is that it opens new routes in the field of biosensing, i.e., development of sensitive, rapid, and simple methods for detecting species based on the fluorescence of the lipid membranes on a polymer film, and provides a spot test technique for the rapid detection of dopamine. The effect of potent interferences including a wide range of compounds usually found in human urine (i.e., ascorbic aid, glucose, leucine, glycine, tartrate, citrate, bicarbonate, and caffeine) was examined using an aqueous buffered solution that contained the potent interference and dopamine at two lower concentration levels (i.e., 3 x 10(-8)-10(-8) M). The effect of proteins and lipids was also investigated at these two lower dopamine concentration levels in aqueous buffered solution. The results showed no interferences from all these constituents at concentrations usually found in human urine samples; for example, albumin up to 3.22 g/L concentration levels did not provide any interference (i.e., no fluorescence). A drop of urine containing this stimulant provided similar results, i.e., a "switching on" of the fluorescence that allows a technique for the rapid detection of this stimulant in human urine at 10(-8) M concentrations. The technique is not based on a calibration graph but is a semiquantitative method for the detection of dopamine in real samples of urine that can be complimentary to HPLC methods. The difference in color between the samples containing dopamine at concentration levels of 10(-8)-10(-7) M can be easily distinguished by naked eye and a digital camera. An increase of dopamine concentration from 10(-8) to 10(-7) M makes the color more blue whereas the color of the filters remains purple in the blank test (i.e., addition of a urine sample without dopamine or dopamine at concentration levels of 10(-9) M to the filters that contain the lipid membranes with incorporated receptor). The reproducibility of the method was checked in approximately 100 samples, and all of them were found to provide similar results. Note that it was also found that the colors remain stable in the samples containing dopamine for periods of more than two months.
Koller, Marianne; Becker, Christian; Thiermann, Horst; Worek, Franz
2010-05-15
The purpose of this study was to check the applicability of different analytical methods for the identification of unknown nerve agents in human body fluids. Plasma and urine samples were spiked with nerve agents (plasma) or with their metabolites (urine) or were left blank. Seven random samples (35% of all samples) were selected for the verification test. Plasma was worked up for unchanged nerve agents and for regenerated nerve agents after fluoride-induced reactivation of nerve agent-inhibited butyrylcholinesterase. Both extracts were analysed by GC-MS. Metabolites were extracted from plasma and urine, respectively, and were analysed by LC-MS. The urinary metabolites and two blank samples could be identified without further measurements, plasma metabolites and blanks were identified in six of seven samples. The analysis of unchanged nerve agent provided five agents/blanks and the sixth agent after further investigation. The determination of the regenerated agents also provided only five clear findings during the first screening because of a rather noisy baseline. Therefore, the sample preparation was extended by a size exclusion step performed before addition of fluoride which visibly reduced baseline noise and thus improved identification of the two missing agents. The test clearly showed that verification should be performed by analysing more than one biomarker to ensure identification of the agent(s). Copyright (c) 2010 Elsevier B.V. All rights reserved.